SIO Argo Site:
Pump Diagnostics Page   



Serial= 7532 WMO= 3902146

Return

←PreviousNext→

Cycle 209 GMT 11/11/2024 10:23:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.04 33 14.85 497 244 0.24 / 1203.08 6 30
2 7 2005.72 40 14.47 3242 1876 2.12 / 1204.96 30 68
3 13 1924.44 20 14.44 3134 905 3.03 / 1205.86 5 72
4 13 1403.80 20 14.45 2427 701 3.73 / 1206.56 5 84
5 13 968.36 20 14.56 1804 525 4.25 / 1207.09 5 90
6 13 386.40 20 14.76 939 277 4.53 / 1207.37 5 89
7 8 0.12 310 14.84 313 1440 5.97 / 1208.81 5 133
Average= 13.74
(KJ/cycle)

Cycle 208 GMT 1/11/2024 13:22:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.80 32 14.84 499 237 0.24 / 1197.09 6 27
2 7 2013.76 40 14.46 3258 1884 2.12 / 1198.97 5 61
3 13 1925.20 20 14.44 3132 905 3.03 / 1199.87 5 70
4 13 1409.76 20 14.46 2440 706 3.73 / 1200.58 5 82
5 13 971.16 20 14.56 1812 528 4.26 / 1201.11 5 89
6 13 305.36 20 14.79 825 244 4.50 / 1201.35 5 88
7 8 -0.08 314 14.84 319 1486 5.99 / 1202.84 5 139
Average= 13.83
(KJ/cycle)

Cycle 207 GMT 22/10/2024 16:14:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.40 33 14.85 492 241 0.24 / 1191.22 6 25
2 7 2004.88 40 14.48 3240 1877 2.12 / 1193.09 25 64
3 13 1917.60 20 14.44 3129 904 3.02 / 1194.00 5 70
4 13 1485.64 20 14.44 2536 732 3.75 / 1194.73 5 78
5 13 851.92 20 14.61 1633 477 4.23 / 1195.20 5 89
6 13 208.64 20 14.83 670 199 4.43 / 1195.40 5 88
7 8 0.16 310 14.84 314 1445 5.87 / 1196.85 5 132
Average= 13.92
(KJ/cycle)

Cycle 206 GMT 12/10/2024 19: 6:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.80 33 14.84 478 234 0.23 / 1185.30 6 33
2 7 2013.12 40 14.48 3243 1878 2.11 / 1187.18 33 67
3 13 1924.32 20 14.45 3141 908 3.02 / 1188.09 5 71
4 13 1415.24 20 14.46 2451 709 3.73 / 1188.80 5 81
5 13 978.32 20 14.56 1823 531 4.26 / 1189.33 5 91
6 13 222.56 20 14.82 689 204 4.46 / 1189.53 5 90
7 8 0.12 308 14.84 315 1440 5.90 / 1190.97 5 129
Average= 14.01
(KJ/cycle)

Cycle 205 GMT 2/10/2024 21:55: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.28 32 14.84 496 236 0.24 / 1179.48 6 31
2 7 2009.72 40 14.47 3251 1882 2.12 / 1181.37 31 67
3 13 1939.04 20 14.44 3164 914 3.03 / 1182.28 5 73
4 13 1429.96 20 14.45 2476 716 3.75 / 1183.00 5 85
5 13 780.76 20 14.63 1539 450 4.20 / 1183.45 5 92
6 13 238.60 20 14.81 717 212 4.41 / 1183.66 5 90
7 8 0.00 304 14.84 313 1412 5.82 / 1185.07 5 132
Average= 14.11
(KJ/cycle)

Cycle 204 GMT 23/ 9/2024 0:38:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.96 32 14.83 480 228 0.23 / 1173.65 5 29
2 7 2005.08 41 14.47 3244 1925 2.15 / 1175.58 29 62
3 13 1921.04 20 14.44 3143 908 3.06 / 1176.48 5 68
4 13 1406.72 20 14.46 2447 708 3.77 / 1177.19 5 82
5 13 743.88 20 14.64 1478 433 4.20 / 1177.62 5 91
6 13 208.96 20 14.83 669 198 4.40 / 1177.82 5 89
7 8 0.04 308 14.84 312 1426 5.82 / 1179.25 5 134
Average= 14.21
(KJ/cycle)

Cycle 203 GMT 13/ 9/2024 3:30:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.84 32 14.84 502 238 0.24 / 1167.74 6 29
2 7 2003.64 40 14.47 3243 1877 2.12 / 1169.61 29 69
3 13 1913.36 20 14.45 3109 899 3.01 / 1170.51 5 72
4 13 1607.16 20 14.42 2702 779 3.79 / 1171.29 5 80
5 13 730.60 20 14.65 1462 428 4.22 / 1171.72 5 93
6 13 296.52 20 14.79 809 239 4.46 / 1171.96 5 92
7 13 19.04 20 14.89 356 106 4.57 / 1172.06 5 82
8 8 0.00 291 14.83 315 1359 5.93 / 1173.42 5 141
Average= 14.31
(KJ/cycle)

Cycle 202 GMT 3/ 9/2024 6:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.20 32 14.84 486 231 0.23 / 1161.78 6 27
2 7 2013.32 41 14.47 3247 1926 2.16 / 1163.70 27 64
3 13 1921.68 20 14.44 3135 905 3.06 / 1164.61 5 71
4 13 1388.04 20 14.46 2408 696 3.76 / 1165.30 5 83
5 13 945.84 20 14.57 1777 518 4.28 / 1165.82 5 91
6 13 267.28 20 14.80 766 227 4.50 / 1166.05 5 93
7 8 0.12 310 14.83 315 1448 5.95 / 1167.50 5 138
Average= 14.41
(KJ/cycle)

Cycle 201 GMT 24/ 8/2024 9:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.72 32 14.84 494 235 0.23 / 1155.96 6 28
2 7 2007.12 40 14.48 3240 1877 2.11 / 1157.84 28 67
3 13 1926.12 20 14.44 3153 911 3.02 / 1158.75 5 70
4 13 1504.64 20 14.44 2559 739 3.76 / 1159.49 5 82
5 13 750.16 20 14.64 1477 432 4.19 / 1159.92 5 93
6 13 206.00 20 14.83 663 197 4.39 / 1160.12 5 92
7 8 0.08 310 14.84 311 1431 5.82 / 1161.55 5 135
Average= 14.52
(KJ/cycle)

Cycle 200 GMT 14/ 8/2024 12: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.88 32 14.85 493 234 0.23 / 1149.96 6 30
2 7 2010.76 40 14.48 3249 1882 2.12 / 1151.84 30 68
3 13 1919.56 20 14.44 3134 905 3.02 / 1152.75 5 74
4 13 1717.52 20 14.40 2871 827 3.85 / 1153.58 5 77
5 13 838.64 20 14.61 1617 472 4.32 / 1154.05 5 93
6 13 288.60 20 14.79 801 237 4.56 / 1154.29 5 91
7 8 0.00 308 14.84 315 1440 6.00 / 1155.73 5 133
Average= 14.63
(KJ/cycle)

Cycle 199 GMT 4/ 8/2024 14:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.52 32 14.84 495 235 0.24 / 1144.07 6 27
2 7 2014.72 40 14.48 3247 1881 2.12 / 1145.95 27 68
3 13 1923.24 20 14.44 3158 912 3.03 / 1146.87 5 70
4 13 1511.80 20 14.44 2576 744 3.77 / 1147.61 5 82
5 13 770.04 20 14.63 1522 445 4.22 / 1148.05 5 92
6 13 231.40 20 14.81 713 211 4.43 / 1148.27 5 92
7 8 0.04 310 14.83 318 1462 5.89 / 1149.73 5 133
Average= 14.74
(KJ/cycle)

Cycle 198 GMT 25/ 7/2024 17:37:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.44 32 14.84 487 231 0.23 / 1138.17 6 28
2 7 2006.32 40 14.47 3247 1879 2.11 / 1140.05 5 69
3 13 1924.08 20 14.44 3146 909 3.02 / 1140.96 5 73
4 13 1398.08 20 14.46 2425 701 3.72 / 1141.66 5 84
5 13 842.76 20 14.60 1632 477 4.20 / 1142.14 5 92
6 13 295.64 20 14.78 811 240 4.44 / 1142.38 5 93
7 8 0.04 308 14.83 320 1462 5.90 / 1143.84 5 142
Average= 14.86
(KJ/cycle)

Cycle 197 GMT 15/ 7/2024 20:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.56 32 14.84 503 239 0.24 / 1132.29 6 20
2 7 2005.08 40 14.48 3239 1876 2.11 / 1134.17 20 64
3 13 1921.08 20 14.45 3124 903 3.02 / 1135.07 5 71
4 13 1495.76 20 14.45 2560 740 3.76 / 1135.81 5 79
5 13 849.76 20 14.61 1629 476 4.23 / 1136.29 5 91
6 13 289.92 20 14.79 798 236 4.47 / 1136.52 5 91
7 8 0.08 306 14.83 312 1416 5.89 / 1137.94 5 136
Average= 14.97
(KJ/cycle)

Cycle 196 GMT 5/ 7/2024 23:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.84 32 14.86 474 225 0.23 / 1126.34 6 24
2 7 2009.40 40 14.48 3247 1881 2.11 / 1128.22 24 69
3 13 1932.52 20 14.45 3153 911 3.02 / 1129.13 5 70
4 13 1528.32 20 14.44 2593 749 3.77 / 1129.88 5 82
5 13 868.76 20 14.59 1664 486 4.25 / 1130.36 5 92
6 13 324.84 20 14.77 856 253 4.50 / 1130.62 5 89
7 8 0.00 304 14.83 319 1438 5.94 / 1132.05 5 143
Average= 15.09
(KJ/cycle)

Cycle 195 GMT 26/ 6/2024 2:19:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.76 32 14.84 495 235 0.24 / 1120.42 6 22
2 7 2005.16 41 14.48 3253 1931 2.17 / 1122.35 22 63
3 13 1914.76 20 14.45 3131 905 3.07 / 1123.25 5 68
4 13 1608.84 20 14.42 2724 786 3.86 / 1124.04 5 77
5 13 843.72 20 14.60 1630 476 4.33 / 1124.51 5 91
6 13 210.36 20 14.83 672 199 4.53 / 1124.71 5 89
7 8 0.16 300 14.84 314 1398 5.93 / 1126.11 5 136
Average= 15.22
(KJ/cycle)

Cycle 194 GMT 16/ 6/2024 5: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.08 32 14.85 487 231 0.23 / 1114.57 6 18
2 7 2004.36 40 14.48 3244 1879 2.11 / 1116.45 18 64
3 13 1915.72 20 14.45 3132 905 3.02 / 1117.36 5 68
4 13 1391.88 20 14.47 2405 696 3.71 / 1118.05 5 82
5 13 754.08 20 14.63 1493 437 4.15 / 1118.49 5 93
6 13 316.24 20 14.78 830 245 4.39 / 1118.74 5 89
7 13 19.72 20 14.88 355 106 4.50 / 1118.84 5 82
8 8 -0.04 289 14.82 313 1341 5.84 / 1120.18 5 146
Average= 15.34
(KJ/cycle)

Cycle 193 GMT 6/ 6/2024 7:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.84 32 14.84 467 222 0.22 / 1108.82 6 25
2 7 2003.56 41 14.48 3242 1925 2.15 / 1110.74 25 69
3 13 1807.24 20 14.47 2985 864 3.01 / 1111.61 5 73
4 13 1397.52 20 14.47 2420 700 3.71 / 1112.31 5 84
5 13 756.72 20 14.63 1502 439 4.15 / 1112.75 5 93
6 13 221.28 20 14.81 698 207 4.36 / 1112.95 5 90
7 8 0.12 300 14.83 312 1388 5.75 / 1114.34 5 129
Average= 15.48
(KJ/cycle)

Cycle 192 GMT 27/ 5/2024 10:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.60 32 14.84 482 229 0.23 / 1102.74 6 18
2 7 2013.48 40 14.49 3250 1884 2.11 / 1104.63 18 64
3 13 1934.32 20 14.44 3161 913 3.03 / 1105.54 5 71
4 13 1617.12 20 14.43 2737 790 3.82 / 1106.33 5 80
5 13 1049.24 20 14.54 1908 555 4.37 / 1106.88 5 89
6 13 363.64 20 14.76 911 269 4.64 / 1107.15 5 91
7 13 29.08 20 14.88 374 111 4.75 / 1107.26 5 82
8 8 -0.04 287 14.83 313 1332 6.08 / 1108.60 5 138
Average= 15.61
(KJ/cycle)

Cycle 191 GMT 17/ 5/2024 13:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.00 32 14.84 482 229 0.23 / 1096.73 6 20
2 7 2014.76 40 14.49 3251 1884 2.11 / 1098.62 20 62
3 13 1921.96 20 14.46 3138 908 3.02 / 1099.52 5 69
4 13 1715.04 20 14.41 2859 824 3.84 / 1100.35 5 76
5 13 845.24 20 14.60 1616 472 4.32 / 1100.82 5 92
6 13 410.32 20 14.74 975 287 4.60 / 1101.11 5 92
7 8 0.04 306 14.83 310 1407 6.01 / 1102.51 5 143
Average= 15.75
(KJ/cycle)

Cycle 190 GMT 7/ 5/2024 16:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.60 32 14.85 487 231 0.23 / 1091.02 6 25
2 7 2015.64 40 14.48 3249 1882 2.11 / 1092.90 25 67
3 13 1925.44 20 14.46 3133 906 3.02 / 1093.81 5 71
4 13 1290.96 20 14.50 2266 657 3.68 / 1094.47 5 85
5 13 761.96 20 14.62 1503 439 4.12 / 1094.90 5 93
6 13 223.16 20 14.81 694 206 4.32 / 1095.11 5 91
7 8 0.20 300 14.83 313 1393 5.71 / 1096.50 5 131
Average= 15.89
(KJ/cycle)

Cycle 189 GMT 27/ 4/2024 19:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.20 32 14.85 490 233 0.23 / 1085.24 6 24
2 7 2003.52 40 14.48 3243 1878 2.11 / 1087.12 24 67
3 13 1918.64 20 14.45 3135 906 3.02 / 1088.03 5 72
4 13 1397.08 20 14.47 2418 700 3.72 / 1088.72 5 84
5 13 866.96 20 14.59 1657 484 4.20 / 1089.21 5 92
6 13 206.60 20 14.82 660 196 4.40 / 1089.40 5 90
7 8 0.12 302 14.84 309 1385 5.78 / 1090.79 5 139
Average= 16.04
(KJ/cycle)

Cycle 188 GMT 17/ 4/2024 22: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.76 32 14.83 465 221 0.22 / 1079.46 6 22
2 7 2005.84 40 14.49 3246 1881 2.10 / 1081.34 22 67
3 13 1919.12 20 14.46 3136 907 3.01 / 1082.24 5 74
4 13 1391.64 20 14.48 2407 697 3.71 / 1082.94 5 84
5 13 859.44 20 14.59 1648 481 4.19 / 1083.42 5 92
6 13 217.72 20 14.82 680 202 4.39 / 1083.62 5 91
7 8 -0.08 300 14.84 311 1385 5.77 / 1085.01 5 144
Average= 16.19
(KJ/cycle)

Cycle 187 GMT 8/ 4/2024 0:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.56 32 14.84 479 227 0.23 / 1073.59 6 23
2 7 2003.68 40 14.49 3244 1880 2.11 / 1075.47 23 68
3 13 1912.24 20 14.46 3118 902 3.01 / 1076.37 5 72
4 13 1492.20 20 14.45 2551 737 3.75 / 1077.11 5 83
5 13 844.52 20 14.60 1627 475 4.22 / 1077.59 5 92
6 13 286.36 20 14.79 791 234 4.46 / 1077.82 5 92
7 13 38.52 20 14.87 386 115 4.57 / 1077.94 5 81
8 8 0.00 280 14.83 313 1300 5.87 / 1079.23 5 135
Average= 16.35
(KJ/cycle)

Cycle 186 GMT 29/ 3/2024 3:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.60 32 14.84 497 236 0.24 / 1067.76 6 21
2 7 2007.36 40 14.49 3241 1878 2.11 / 1069.64 21 68
3 13 1926.64 20 14.46 3149 911 3.03 / 1070.55 5 73
4 13 1482.88 20 14.45 2539 734 3.76 / 1071.28 5 80
5 13 812.48 20 14.61 1573 460 4.22 / 1071.74 5 94
6 13 276.32 20 14.79 769 227 4.45 / 1071.97 5 90
7 8 0.24 304 14.83 310 1398 5.84 / 1073.36 5 136
Average= 16.51
(KJ/cycle)

Cycle 185 GMT 19/ 3/2024 6:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.40 32 14.85 471 224 0.22 / 1062.01 6 19
2 7 2003.60 40 14.49 3236 1876 2.10 / 1063.89 19 70
3 13 1910.36 20 14.46 3124 903 3.00 / 1064.79 5 74
4 13 1300.12 20 14.49 2275 659 3.66 / 1065.45 5 87
5 13 765.68 20 14.62 1512 442 4.10 / 1065.89 5 92
6 13 228.56 20 14.81 704 209 4.31 / 1066.10 5 90
7 8 0.08 302 14.83 317 1420 5.73 / 1067.52 5 134
Average= 16.68
(KJ/cycle)

Cycle 184 GMT 9/ 3/2024 9:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.08 32 14.83 468 222 0.22 / 1056.19 6 24
2 7 2005.72 40 14.49 3244 1880 2.10 / 1058.07 24 70
3 13 1921.00 20 14.46 3145 910 3.01 / 1058.98 5 72
4 13 1492.60 20 14.45 2553 738 3.75 / 1059.72 5 82
5 13 840.76 20 14.60 1624 474 4.22 / 1060.19 5 93
6 13 204.60 20 14.82 665 197 4.42 / 1060.39 5 91
7 8 0.04 300 14.83 314 1397 5.82 / 1061.79 5 142
Average= 16.85
(KJ/cycle)

Cycle 183 GMT 28/ 2/2024 12:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.40 32 14.84 473 225 0.22 / 1050.19 6 21
2 7 2017.48 40 14.48 3267 1892 2.12 / 1052.08 21 64
3 13 1936.08 20 14.46 3164 915 3.03 / 1052.99 5 70
4 13 1625.80 20 14.43 2745 792 3.82 / 1053.79 5 77
5 13 942.64 20 14.56 1771 516 4.34 / 1054.30 5 91
6 13 364.48 20 14.75 905 267 4.61 / 1054.57 5 90
7 8 0.04 302 14.83 313 1402 6.01 / 1055.97 5 135
Average= 17.03
(KJ/cycle)

Cycle 182 GMT 18/ 2/2024 15:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.84 32 14.84 484 230 0.23 / 1044.36 6 24
2 7 2007.28 40 14.50 3245 1882 2.11 / 1046.24 24 69
3 13 1921.64 20 14.46 3141 908 3.02 / 1047.15 5 74
4 13 1392.88 20 14.48 2412 699 3.72 / 1047.85 5 84
5 13 858.28 20 14.59 1651 482 4.20 / 1048.33 5 92
6 13 305.36 20 14.77 815 241 4.44 / 1048.57 5 92
7 8 -0.04 297 14.83 316 1392 5.83 / 1049.96 5 132
Average= 17.21
(KJ/cycle)

Cycle 181 GMT 8/ 2/2024 18:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.60 32 14.84 487 231 0.23 / 1038.47 6 22
2 7 2006.28 40 14.49 3243 1880 2.11 / 1040.35 5 70
3 13 1919.68 20 14.46 3141 908 3.02 / 1041.25 5 73
4 13 1596.84 20 14.44 2685 775 3.79 / 1042.03 5 81
5 13 731.96 20 14.64 1464 429 4.22 / 1042.46 5 93
6 13 285.60 20 14.78 797 236 4.46 / 1042.69 5 91
7 13 35.96 20 14.87 389 116 4.57 / 1042.81 5 81
8 8 0.12 280 14.82 318 1320 5.89 / 1044.13 5 137
Average= 17.40
(KJ/cycle)

Cycle 180 GMT 29/ 1/2024 21:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.56 32 14.85 486 231 0.23 / 1032.61 6 21
2 7 2003.72 40 14.50 3238 1878 2.11 / 1034.49 21 64
3 13 1920.24 20 14.47 3135 907 3.02 / 1035.40 5 69
4 13 1409.60 20 14.48 2429 703 3.72 / 1036.10 5 82
5 13 874.24 20 14.58 1673 488 4.21 / 1036.59 5 91
6 13 323.32 20 14.76 844 249 4.46 / 1036.84 5 91
7 8 -0.04 302 14.83 312 1397 5.85 / 1038.23 5 137
Average= 17.60
(KJ/cycle)

Cycle 179 GMT 20/ 1/2024 0: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.28 32 14.84 481 228 0.23 / 1026.79 6 22
2 7 2013.64 40 14.50 3247 1883 2.11 / 1028.67 22 67
3 13 1926.20 20 14.46 3136 907 3.02 / 1029.58 5 75
4 13 1416.04 20 14.47 2437 705 3.72 / 1030.28 5 84
5 13 891.60 20 14.58 1682 490 4.21 / 1030.77 5 92
6 13 237.40 20 14.80 710 210 4.42 / 1030.98 5 90
7 8 0.16 304 14.83 310 1398 5.82 / 1032.38 5 138
Average= 17.80
(KJ/cycle)

Cycle 178 GMT 10/ 1/2024 2:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.68 32 14.84 470 223 0.22 / 1020.99 6 22
2 7 2005.44 40 14.50 3244 1882 2.10 / 1022.87 22 63
3 13 1921.96 20 14.47 3129 906 3.01 / 1023.78 5 67
4 13 1410.40 20 14.47 2431 704 3.71 / 1024.48 5 83
5 13 877.20 20 14.58 1671 487 4.20 / 1024.97 5 91
6 13 209.08 20 14.81 671 199 4.40 / 1025.17 5 89
7 8 -0.04 300 14.82 313 1392 5.79 / 1026.56 5 145
Average= 18.01
(KJ/cycle)

Cycle 177 GMT 31/12/2023 5:21: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.36 32 14.83 472 224 0.22 / 1015.11 6 24
2 7 2005.16 40 14.50 3243 1881 2.10 / 1016.99 24 68
3 13 1918.52 20 14.47 3136 908 3.01 / 1017.89 5 74
4 13 1593.40 20 14.45 2684 776 3.79 / 1018.67 5 81
5 13 832.40 20 14.60 1611 470 4.26 / 1019.14 5 93
6 13 311.40 20 14.77 807 238 4.50 / 1019.38 5 86
7 8 0.12 302 14.83 310 1388 5.89 / 1020.77 5 141
Average= 18.23
(KJ/cycle)

Cycle 176 GMT 21/12/2023 8:13: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.28 32 14.84 480 228 0.23 / 1009.36 6 23
2 7 2004.76 40 14.50 3240 1879 2.11 / 1011.24 23 70
3 13 1922.16 20 14.47 3144 910 3.02 / 1012.15 5 73
4 13 1402.16 20 14.48 2418 700 3.72 / 1012.85 5 83
5 13 788.92 20 14.61 1539 450 4.17 / 1013.30 5 93
6 13 242.32 20 14.79 716 212 4.38 / 1013.51 5 91
7 8 0.04 300 14.82 309 1374 5.75 / 1014.88 5 136
Average= 18.45
(KJ/cycle)

Cycle 175 GMT 11/12/2023 10:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.44 32 14.83 470 223 0.22 / 1003.56 6 23
2 7 2007.00 40 14.49 3239 1877 2.10 / 1005.44 23 64
3 13 1924.32 20 14.47 3141 909 3.01 / 1006.35 5 69
4 13 1607.88 20 14.44 2716 784 3.79 / 1007.14 5 79
5 13 725.24 20 14.64 1453 425 4.22 / 1007.56 5 91
6 13 193.32 20 14.82 639 189 4.41 / 1007.75 5 88
7 8 0.08 300 14.83 310 1379 5.79 / 1009.13 5 132
Average= 18.69
(KJ/cycle)

Cycle 174 GMT 1/12/2023 13:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.88 32 14.83 479 227 0.23 / 997.73 6 24
2 7 2003.36 41 14.50 3238 1925 2.15 / 999.65 24 65
3 13 1915.24 20 14.47 3127 905 3.06 / 1000.56 5 69
4 13 1379.72 20 14.48 2385 691 3.75 / 1001.25 5 82
5 13 833.64 20 14.60 1599 467 4.21 / 1001.71 5 92
6 13 274.12 20 14.78 772 228 4.44 / 1001.94 5 90
7 13 40.16 20 14.87 383 114 4.56 / 1002.05 5 80
8 8 0.20 280 14.82 310 1286 5.84 / 1003.34 5 132
Average= 18.93
(KJ/cycle)

Cycle 173 GMT 21/11/2023 16:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.48 32 14.83 478 227 0.23 / 992.00 6 25
2 7 2009.76 40 14.50 3247 1883 2.11 / 993.88 25 67
3 13 1915.08 20 14.47 3134 907 3.02 / 994.79 5 73
4 13 1303.76 20 14.50 2287 663 3.68 / 995.45 5 87
5 13 779.32 20 14.61 1533 448 4.13 / 995.90 5 92
6 13 241.00 20 14.79 722 214 4.34 / 996.12 5 93
7 8 0.08 297 14.82 314 1382 5.72 / 997.50 5 131
Average= 19.18
(KJ/cycle)

Cycle 172 GMT 11/11/2023 19:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.48 32 14.83 496 235 0.24 / 986.03 6 26
2 7 2003.36 40 14.50 3230 1873 2.11 / 987.91 26 67
3 13 1919.36 20 14.47 3144 910 3.02 / 988.82 5 74
4 13 1722.44 20 14.42 2867 827 3.85 / 989.64 5 78
5 13 837.52 20 14.60 1607 469 4.31 / 990.11 5 93
6 13 295.52 20 14.78 806 238 4.55 / 990.35 5 91
7 8 0.08 306 14.82 314 1424 5.98 / 991.77 5 146
Average= 19.45
(KJ/cycle)

Cycle 171 GMT 1/11/2023 22:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.48 32 14.83 487 231 0.23 / 980.08 6 26
2 7 2013.12 40 14.50 3261 1891 2.12 / 981.97 26 65
3 13 1921.00 20 14.48 3139 909 3.03 / 982.88 5 71
4 13 1607.80 20 14.44 2713 784 3.82 / 983.66 5 80
5 13 943.80 20 14.57 1771 516 4.33 / 984.18 5 90
6 13 276.04 20 14.78 774 229 4.56 / 984.41 5 92
7 8 0.08 302 14.82 311 1392 5.95 / 985.80 5 129
Average= 19.72
(KJ/cycle)

Cycle 170 GMT 23/10/2023 1: 3:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.08 32 14.83 484 230 0.23 / 974.25 6 26
2 7 2008.44 40 14.51 3246 1884 2.11 / 976.14 26 69
3 13 1925.92 20 14.48 3141 910 3.02 / 977.05 5 74
4 13 1425.20 20 14.48 2443 707 3.73 / 977.75 5 86
5 13 872.44 20 14.59 1669 487 4.22 / 978.24 5 93
6 13 227.52 20 14.80 699 207 4.42 / 978.45 5 92
7 8 0.08 302 14.82 312 1396 5.82 / 979.85 5 134
Average= 20.00
(KJ/cycle)

Cycle 169 GMT 13/10/2023 3:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.00 32 14.81 491 233 0.23 / 968.26 6 27
2 7 2007.72 41 14.50 3254 1935 2.17 / 970.20 27 70
3 13 1922.28 20 14.47 3136 908 3.07 / 971.11 5 72
4 13 1491.84 20 14.47 2549 738 3.81 / 971.84 5 84
5 13 1037.68 20 14.54 1903 553 4.37 / 972.40 5 90
6 13 227.04 20 14.80 705 209 4.57 / 972.60 5 92
7 8 0.04 304 14.82 315 1419 5.99 / 974.02 5 142
Average= 20.29
(KJ/cycle)

Cycle 168 GMT 3/10/2023 6:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.20 32 14.83 486 231 0.23 / 962.21 6 27
2 7 2005.72 40 14.50 3242 1880 2.11 / 964.09 27 71
3 13 1919.32 20 14.48 3133 907 3.02 / 965.00 5 73
4 13 1612.80 20 14.45 2723 787 3.81 / 965.78 5 81
5 13 1140.92 20 14.51 2050 595 4.40 / 966.38 5 91
6 13 239.60 20 14.79 715 211 4.61 / 966.59 5 93
7 8 -0.04 308 14.81 316 1441 6.05 / 968.03 5 147
Average= 20.60
(KJ/cycle)

Cycle 167 GMT 23/ 9/2023 9:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.84 32 14.82 484 230 0.23 / 956.47 6 26
2 7 2015.08 40 14.50 3271 1897 2.13 / 958.37 26 65
3 13 1921.20 20 14.48 3147 911 3.04 / 959.28 5 67
4 13 1300.80 20 14.50 2285 663 3.70 / 959.94 5 84
5 13 676.84 20 14.65 1377 403 4.10 / 960.34 5 91
6 13 251.32 20 14.79 738 218 4.32 / 960.56 5 91
7 13 41.52 20 14.86 392 117 4.44 / 960.68 5 80
8 8 -0.04 280 14.82 313 1299 5.74 / 961.98 5 131
Average= 20.91
(KJ/cycle)

Cycle 166 GMT 13/ 9/2023 12:18:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.72 32 14.83 494 234 0.23 / 950.49 6 25
2 7 2004.96 40 14.51 3248 1885 2.12 / 952.37 25 68
3 13 1921.00 20 14.48 3148 912 3.03 / 953.28 5 75
4 13 1482.84 20 14.47 2540 735 3.77 / 954.02 5 83
5 13 924.60 20 14.57 1740 507 4.27 / 954.53 5 92
6 13 353.12 20 14.74 878 259 4.53 / 954.78 5 88
7 13 66.44 20 14.84 435 129 4.66 / 954.91 5 83
8 8 0.04 287 14.81 312 1326 5.99 / 956.24 5 138
Average= 21.25
(KJ/cycle)

Cycle 165 GMT 3/ 9/2023 15:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.52 32 14.83 485 230 0.23 / 944.68 6 23
2 7 2008.20 40 14.51 3251 1887 2.12 / 946.56 23 67
3 13 1923.36 20 14.48 3144 911 3.03 / 947.47 5 72
4 13 1499.24 20 14.46 2555 739 3.77 / 948.21 5 83
5 13 748.04 20 14.62 1484 434 4.20 / 948.65 5 94
6 13 221.08 20 14.80 694 205 4.41 / 948.85 5 90
7 8 0.16 300 14.82 315 1400 5.81 / 950.25 5 132
Average= 21.60
(KJ/cycle)

Cycle 164 GMT 24/ 8/2023 18: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.52 32 14.82 484 230 0.23 / 938.91 6 24
2 7 2007.80 40 14.51 3247 1885 2.11 / 940.79 24 67
3 13 1920.12 20 14.47 3148 911 3.03 / 941.70 5 72
4 13 1394.12 20 14.49 2414 700 3.72 / 942.40 5 85
5 13 752.36 20 14.62 1500 439 4.16 / 942.84 5 93
6 13 216.20 20 14.80 688 204 4.37 / 943.05 5 90
7 8 0.04 300 14.82 315 1400 5.77 / 944.45 5 132
Average= 21.96
(KJ/cycle)

Cycle 163 GMT 14/ 8/2023 20:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.72 32 14.83 489 232 0.23 / 933.17 6 24
2 7 2004.52 40 14.51 3240 1880 2.11 / 935.05 24 68
3 13 1920.16 20 14.47 3147 911 3.02 / 935.96 5 75
4 13 1396.28 20 14.49 2411 699 3.72 / 936.66 5 84
5 13 663.24 20 14.66 1360 399 4.12 / 937.06 5 92
6 13 239.88 20 14.79 723 214 4.33 / 937.27 5 91
7 8 0.00 300 14.81 317 1408 5.74 / 938.68 5 133
Average= 22.35
(KJ/cycle)

Cycle 162 GMT 4/ 8/2023 23:19:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.52 32 14.82 489 232 0.23 / 927.35 6 23
2 7 2004.24 40 14.52 3248 1886 2.12 / 929.24 23 67
3 13 1919.32 20 14.49 3148 912 3.03 / 930.15 5 73
4 13 1405.28 20 14.49 2433 705 3.74 / 930.85 5 84
5 13 763.80 20 14.62 1509 441 4.18 / 931.29 5 93
6 13 238.72 20 14.79 724 214 4.39 / 931.51 5 89
7 8 -0.04 302 14.81 319 1427 5.82 / 932.94 5 134
Average= 22.75
(KJ/cycle)

Cycle 161 GMT 26/ 7/2023 2: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.12 32 14.82 486 230 0.23 / 921.52 6 26
2 7 2006.88 40 14.51 3256 1890 2.12 / 923.41 26 69
3 13 1913.24 20 14.49 3132 908 3.03 / 924.32 5 74
4 13 1485.32 20 14.49 2539 736 3.76 / 925.06 5 83
5 13 738.16 20 14.63 1471 430 4.19 / 925.49 5 93
6 13 209.96 20 14.81 670 198 4.39 / 925.69 5 91
7 8 0.16 304 14.81 318 1432 5.82 / 927.12 5 142
Average= 23.18
(KJ/cycle)

Cycle 160 GMT 16/ 7/2023 4:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.20 32 14.82 483 229 0.23 / 915.51 6 23
2 7 2003.16 40 14.52 3236 1879 2.11 / 917.39 23 68
3 13 1912.96 20 14.49 3129 907 3.02 / 918.29 5 72
4 13 1706.32 20 14.44 2852 824 3.84 / 919.12 5 81
5 13 914.80 20 14.58 1733 505 4.34 / 919.62 5 91
6 13 351.12 20 14.75 884 261 4.61 / 919.88 5 90
7 8 -0.04 304 14.82 313 1410 6.02 / 921.29 5 136
Average= 23.62
(KJ/cycle)

Cycle 159 GMT 6/ 7/2023 7:56: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.68 32 14.82 478 227 0.23 / 909.72 6 23
2 7 2004.52 40 14.52 3241 1882 2.11 / 911.60 23 68
3 13 1919.60 20 14.49 3136 909 3.02 / 912.51 5 74
4 13 1381.40 20 14.51 2389 693 3.71 / 913.20 5 85
5 13 730.72 20 14.63 1465 429 4.14 / 913.63 5 93
6 13 188.80 20 14.81 641 190 4.33 / 913.82 5 90
7 13 17.36 20 14.87 359 107 4.44 / 913.93 5 83
8 8 -0.12 287 14.80 318 1351 5.79 / 915.28 5 140
Average= 24.09
(KJ/cycle)

Cycle 158 GMT 26/ 6/2023 10:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.32 32 14.81 485 230 0.23 / 903.82 6 22
2 7 2008.60 40 14.52 3245 1885 2.11 / 905.70 22 69
3 13 1913.84 20 14.48 3124 905 3.02 / 906.61 5 75
4 13 1598.16 20 14.46 2689 778 3.80 / 907.39 5 80
5 13 832.08 20 14.60 1610 470 4.27 / 907.86 5 92
6 13 181.08 20 14.81 623 185 4.45 / 908.04 5 88
7 8 0.08 312 14.81 314 1451 5.90 / 909.49 5 134
Average= 24.58
(KJ/cycle)

Cycle 157 GMT 16/ 6/2023 13:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.08 32 14.82 493 234 0.23 / 898.06 6 21
2 7 2003.52 40 14.51 3245 1883 2.12 / 899.94 21 69
3 13 1917.20 20 14.48 3145 911 3.03 / 900.85 5 71
4 13 1296.68 20 14.51 2265 657 3.69 / 901.51 5 86
5 13 768.80 20 14.62 1510 442 4.13 / 901.95 5 92
6 13 225.92 20 14.79 697 206 4.33 / 902.16 5 88
7 13 26.08 20 14.86 371 110 4.44 / 902.27 5 82
8 8 0.04 282 14.80 316 1319 5.76 / 903.59 5 131
Average= 25.10
(KJ/cycle)

Cycle 156 GMT 6/ 6/2023 16:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.44 32 14.82 481 228 0.23 / 892.18 6 22
2 7 2004.24 40 14.52 3239 1881 2.11 / 894.06 22 69
3 13 1914.80 20 14.48 3131 907 3.02 / 894.97 5 72
4 13 1395.48 20 14.50 2415 700 3.72 / 895.67 5 84
5 13 967.32 20 14.56 1795 523 4.24 / 896.19 5 91
6 13 287.56 20 14.77 790 233 4.47 / 896.42 5 88
7 8 -0.04 302 14.81 314 1404 5.88 / 897.83 5 132
Average= 25.65
(KJ/cycle)

Cycle 155 GMT 27/ 5/2023 19:11: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.16 32 14.82 487 231 0.23 / 886.36 6 21
2 7 2009.00 40 14.52 3251 1888 2.12 / 888.25 21 65
3 13 1923.24 20 14.49 3149 913 3.03 / 889.17 5 68
4 13 1404.12 20 14.50 2424 703 3.73 / 889.87 5 80
5 13 763.20 20 14.62 1501 439 4.17 / 890.31 5 91
6 13 323.56 20 14.75 836 247 4.42 / 890.55 5 89
7 8 0.12 300 14.81 314 1395 5.82 / 891.95 5 139
Average= 26.23
(KJ/cycle)

Cycle 154 GMT 17/ 5/2023 21:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.20 32 14.81 483 229 0.23 / 880.56 6 21
2 7 2011.96 40 14.51 3247 1885 2.11 / 882.45 21 71
3 13 1917.76 20 14.48 3147 911 3.02 / 883.36 5 75
4 13 1411.16 20 14.49 2434 705 3.73 / 884.06 5 84
5 13 865.96 20 14.58 1663 485 4.22 / 884.55 5 92
6 13 204.36 20 14.80 664 197 4.41 / 884.74 5 89
7 8 0.08 300 14.81 313 1391 5.80 / 886.13 5 150
Average= 26.85
(KJ/cycle)

Cycle 153 GMT 8/ 5/2023 0:34: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.72 32 14.82 482 229 0.23 / 874.69 6 20
2 7 2006.36 40 14.52 3247 1886 2.11 / 876.58 20 65
3 13 1922.88 20 14.48 3141 910 3.02 / 877.49 5 69
4 13 1494.08 20 14.47 2565 742 3.77 / 878.23 5 80
5 13 844.76 20 14.59 1625 474 4.24 / 878.70 5 91
6 13 275.88 20 14.77 776 229 4.47 / 878.93 5 90
7 13 17.08 20 14.86 352 105 4.57 / 879.04 5 78
8 8 -0.04 280 14.80 312 1293 5.87 / 880.33 5 131
Average= 27.51
(KJ/cycle)

Cycle 152 GMT 28/ 4/2023 3:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.48 32 14.82 478 227 0.23 / 868.96 6 23
2 7 2003.24 40 14.52 3242 1883 2.11 / 870.85 23 68
3 13 1915.16 20 14.49 3127 906 3.02 / 871.75 5 73
4 13 1387.24 20 14.50 2401 696 3.71 / 872.45 5 85
5 13 742.72 20 14.63 1480 433 4.15 / 872.88 5 92
6 13 200.60 20 14.80 660 195 4.34 / 873.08 5 90
7 8 0.04 300 14.81 312 1386 5.73 / 874.46 5 139
Average= 28.21
(KJ/cycle)

Cycle 151 GMT 18/ 4/2023 6:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.40 32 14.82 474 225 0.22 / 863.09 6 21
2 7 2003.80 40 14.52 3235 1879 2.10 / 864.97 21 63
3 13 1909.36 20 14.50 3114 903 3.01 / 865.88 5 71
4 13 1494.72 20 14.48 2549 738 3.74 / 866.61 5 81
5 13 829.56 20 14.60 1605 469 4.21 / 867.08 5 91
6 13 273.08 20 14.78 764 226 4.44 / 867.31 5 86
7 13 34.16 20 14.86 386 115 4.55 / 867.42 5 80
8 8 0.08 281 14.80 316 1314 5.87 / 868.74 5 136
Average= 28.96
(KJ/cycle)

Cycle 150 GMT 8/ 4/2023 9:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.76 32 14.81 495 235 0.23 / 857.35 6 19
2 7 2006.24 40 14.52 3239 1881 2.12 / 859.23 19 69
3 13 1922.44 20 14.49 3144 911 3.03 / 860.14 5 74
4 13 1299.84 20 14.52 2288 664 3.69 / 860.81 5 87
5 13 883.40 20 14.58 1686 492 4.18 / 861.30 5 92
6 13 217.96 20 14.79 688 204 4.39 / 861.50 5 90
7 8 0.00 295 14.81 313 1367 5.75 / 862.87 5 134
Average= 29.75
(KJ/cycle)

Cycle 149 GMT 29/ 3/2023 12: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.56 32 14.83 475 225 0.23 / 851.55 6 20
2 7 2006.76 40 14.51 3248 1885 2.11 / 853.44 20 68
3 13 1911.20 20 14.49 3125 906 3.02 / 854.34 5 72
4 13 1396.48 20 14.50 2412 699 3.72 / 855.04 5 84
5 13 854.48 20 14.59 1642 479 4.19 / 855.52 5 93
6 13 190.32 20 14.80 640 189 4.38 / 855.71 5 89
7 13 40.16 20 14.85 395 117 4.50 / 855.83 5 81
8 8 0.00 278 14.80 313 1288 5.79 / 857.12 5 130
Average= 30.61
(KJ/cycle)

Cycle 148 GMT 19/ 3/2023 14:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.36 32 14.81 489 232 0.23 / 845.89 6 23
2 7 2004.88 40 14.52 3245 1885 2.12 / 847.78 23 71
3 13 1916.20 20 14.50 3128 907 3.02 / 848.69 5 72
4 13 1391.92 20 14.50 2410 699 3.72 / 849.39 5 84
5 13 646.72 20 14.67 1324 388 4.11 / 849.77 5 92
6 13 215.76 20 14.80 679 201 4.31 / 849.97 5 89
7 8 -0.04 297 14.82 307 1351 5.66 / 851.33 5 134
Average= 31.53
(KJ/cycle)

Cycle 147 GMT 9/ 3/2023 17:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.52 32 14.82 489 232 0.23 / 839.90 6 20
2 7 2005.00 40 14.53 3253 1891 2.12 / 841.80 20 68
3 13 1920.12 20 14.50 3156 915 3.04 / 842.71 5 72
4 13 1512.28 20 14.48 2576 746 3.78 / 843.46 5 81
5 13 1051.08 20 14.53 1927 560 4.34 / 844.02 5 91
6 13 249.56 20 14.78 734 217 4.56 / 844.23 5 90
7 13 27.24 20 14.85 371 110 4.67 / 844.34 5 82
8 8 0.00 282 14.80 316 1319 5.99 / 845.66 5 130
Average= 32.53
(KJ/cycle)

Cycle 146 GMT 27/ 2/2023 20:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.68 32 14.81 489 232 0.23 / 833.93 6 21
2 7 2006.60 40 14.53 3243 1885 2.12 / 835.82 21 71
3 13 1919.52 20 14.50 3133 909 3.03 / 836.73 5 73
4 13 1593.60 20 14.48 2695 780 3.81 / 837.51 5 83
5 13 820.44 20 14.61 1594 466 4.27 / 837.97 5 93
6 13 369.84 20 14.74 915 270 4.54 / 838.24 5 89
7 13 26.84 20 14.86 373 111 4.65 / 838.36 5 81
8 8 0.04 280 14.80 318 1318 5.97 / 839.67 5 129
Average= 33.59
(KJ/cycle)

Cycle 145 GMT 17/ 2/2023 23:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.80 32 14.82 483 229 0.23 / 828.18 6 22
2 7 2003.40 40 14.53 3233 1879 2.11 / 830.06 22 69
3 13 1915.60 20 14.50 3130 908 3.02 / 830.97 5 73
4 13 1377.56 20 14.51 2384 692 3.71 / 831.66 5 84
5 13 746.36 20 14.63 1474 431 4.14 / 832.09 5 92
6 13 198.08 20 14.81 655 194 4.33 / 832.29 5 90
7 8 0.04 302 14.81 317 1418 5.75 / 833.70 5 131
Average= 34.74
(KJ/cycle)

Cycle 144 GMT 8/ 2/2023 2:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.16 32 14.80 486 230 0.23 / 822.30 6 24
2 7 2003.44 40 14.53 3241 1884 2.11 / 824.18 24 68
3 13 1918.52 20 14.50 3144 912 3.03 / 825.10 5 73
4 13 1396.80 20 14.50 2409 699 3.72 / 825.79 5 84
5 13 961.84 20 14.56 1804 525 4.25 / 826.32 5 91
6 13 288.20 20 14.77 788 233 4.48 / 826.55 5 89
7 8 0.00 302 14.81 313 1400 5.88 / 827.95 5 148
Average= 36.00
(KJ/cycle)

Cycle 143 GMT 29/ 1/2023 5:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.92 32 14.81 492 233 0.23 / 816.49 6 25
2 7 2012.00 40 14.53 3254 1891 2.12 / 818.39 25 71
3 13 1916.96 20 14.50 3140 911 3.03 / 819.30 5 73
4 13 1379.92 20 14.52 2385 693 3.73 / 819.99 5 87
5 13 842.12 20 14.60 1633 477 4.20 / 820.47 5 93
6 13 191.72 20 14.81 645 191 4.40 / 820.66 5 90
7 8 -0.12 304 14.81 314 1414 5.81 / 822.07 5 135
Average= 37.37
(KJ/cycle)

Cycle 142 GMT 19/ 1/2023 8: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.04 32 14.81 502 238 0.24 / 810.65 6 25
2 7 2008.16 40 14.53 3259 1894 2.13 / 812.55 25 67
3 13 1930.56 20 14.51 3151 914 3.05 / 813.46 5 73
4 13 1492.64 20 14.49 2557 741 3.79 / 814.20 5 82
5 13 732.72 20 14.64 1466 429 4.22 / 814.63 5 93
6 13 201.20 20 14.81 659 195 4.41 / 814.83 5 91
7 13 18.72 20 14.87 362 108 4.52 / 814.93 5 81
8 8 -0.12 280 14.80 320 1326 5.85 / 816.26 5 131
Average= 38.87
(KJ/cycle)

Cycle 141 GMT 9/ 1/2023 10:56: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.24 32 14.82 488 231 0.23 / 804.74 6 24
2 7 2004.44 40 14.53 3241 1884 2.12 / 806.62 24 72
3 13 1913.28 20 14.51 3134 909 3.02 / 807.53 5 77
4 13 1392.56 20 14.51 2412 700 3.72 / 808.23 5 85
5 13 952.84 20 14.57 1784 520 4.24 / 808.75 5 92
6 13 254.32 20 14.78 748 221 4.47 / 808.98 5 93
7 8 0.00 306 14.80 318 1440 5.91 / 810.42 5 138
Average= 40.52
(KJ/cycle)

Cycle 140 GMT 30/12/2022 13:51:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.12 32 14.81 494 234 0.23 / 798.91 6 26
2 7 2003.56 40 14.53 3244 1885 2.12 / 800.79 26 63
3 13 1911.04 20 14.50 3136 909 3.03 / 801.70 5 72
4 13 1590.60 20 14.48 2685 778 3.81 / 802.48 5 78
5 13 814.08 20 14.62 1580 462 4.27 / 802.94 5 93
6 13 171.20 20 14.82 607 180 4.45 / 803.12 5 89
7 8 0.12 295 14.82 318 1390 5.84 / 804.51 5 131
Average= 42.34
(KJ/cycle)

Cycle 139 GMT 20/12/2022 16:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.32 32 14.81 482 228 0.23 / 793.12 6 29
2 7 2006.64 40 14.53 3244 1885 2.11 / 795.01 29 68
3 13 1819.16 20 14.51 3014 875 2.99 / 795.88 5 76
4 13 1401.76 20 14.51 2425 704 3.69 / 796.59 5 85
5 13 854.72 20 14.59 1640 479 4.17 / 797.07 5 95
6 13 191.68 20 14.81 644 191 4.36 / 797.26 5 90
7 8 0.08 302 14.81 316 1413 5.77 / 798.67 5 137
Average= 44.37
(KJ/cycle)

Cycle 138 GMT 10/12/2022 19:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.04 32 14.81 497 236 0.24 / 787.34 6 29
2 7 2012.88 41 14.53 3264 1944 2.18 / 789.29 29 67
3 13 1917.68 20 14.51 3139 911 3.09 / 790.20 5 74
4 13 1382.28 20 14.51 2400 696 3.79 / 790.89 5 84
5 13 644.60 20 14.67 1333 391 4.18 / 791.28 5 94
6 13 229.12 20 14.80 704 208 4.39 / 791.49 5 91
7 8 0.00 300 14.81 316 1404 5.79 / 792.90 5 142
Average= 46.64
(KJ/cycle)

Cycle 137 GMT 30/11/2022 22:18:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.16 32 14.83 481 228 0.23 / 781.38 6 22
2 7 2007.80 41 14.53 3248 1935 2.16 / 783.31 22 66
3 13 1920.36 20 14.50 3144 912 3.07 / 784.22 5 73
4 13 1600.28 20 14.47 2707 783 3.86 / 785.01 5 82
5 13 801.72 20 14.62 1567 458 4.32 / 785.47 5 93
6 13 242.16 20 14.79 732 217 4.53 / 785.68 5 92
7 8 0.00 302 14.81 318 1422 5.96 / 787.11 5 134
Average= 49.19
(KJ/cycle)

Cycle 136 GMT 21/11/2022 1:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.68 32 14.82 475 225 0.23 / 775.56 6 28
2 7 2005.40 40 14.54 3240 1884 2.11 / 777.45 28 70
3 13 1916.52 20 14.52 3136 911 3.02 / 778.36 5 75
4 13 1390.56 20 14.52 2404 698 3.72 / 779.06 5 86
5 13 851.92 20 14.60 1644 480 4.20 / 779.54 5 92
6 13 203.68 20 14.80 667 197 4.40 / 779.74 5 89
7 8 0.08 304 14.82 314 1415 5.81 / 781.15 5 131
Average= 52.08
(KJ/cycle)

Cycle 135 GMT 11/11/2022 4: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.76 32 14.80 490 232 0.23 / 769.73 5 26
2 7 2012.36 40 14.54 3259 1895 2.13 / 771.62 26 63
3 13 1932.32 20 14.51 3163 918 3.05 / 772.54 5 73
4 13 1503.16 20 14.50 2564 744 3.79 / 773.29 5 84
5 13 853.44 20 14.60 1649 482 4.27 / 773.77 5 92
6 13 201.48 20 14.82 659 195 4.47 / 773.96 5 90
7 8 0.12 295 14.82 315 1377 5.84 / 775.34 5 129
Average= 55.38
(KJ/cycle)

Cycle 134 GMT 1/11/2022 7: 3:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.40 32 14.82 492 233 0.23 / 763.66 6 31
2 7 2011.12 41 14.54 3242 1933 2.17 / 765.59 31 69
3 13 1914.76 20 14.51 3131 909 3.07 / 766.50 5 75
4 13 1581.60 20 14.49 2679 776 3.85 / 767.27 5 84
5 13 895.44 20 14.60 1698 496 4.35 / 767.77 5 94
6 13 318.76 20 14.77 837 247 4.59 / 768.02 5 91
7 8 0.04 314 14.81 318 1479 6.07 / 769.50 5 134
Average= 59.19
(KJ/cycle)

Cycle 133 GMT 22/10/2022 10:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.24 32 14.81 495 235 0.23 / 757.76 5 30
2 7 2008.60 40 14.54 3249 1890 2.12 / 759.65 30 68
3 13 1926.28 20 14.51 3139 911 3.04 / 760.56 5 74
4 13 1494.72 20 14.50 2561 743 3.78 / 761.30 5 84
5 13 946.04 20 14.58 1771 516 4.29 / 761.82 5 93
6 13 166.60 20 14.83 606 180 4.47 / 762.00 5 89
7 8 0.00 302 14.82 319 1428 5.90 / 763.42 5 129
Average= 63.62
(KJ/cycle)

Cycle 132 GMT 12/10/2022 13: 2:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.40 32 14.81 485 230 0.23 / 751.95 5 32
2 7 2005.52 40 14.54 3247 1888 2.12 / 753.84 32 68
3 13 1918.96 20 14.52 3135 910 3.03 / 754.75 5 75
4 13 1304.96 20 14.54 2281 663 3.69 / 755.41 5 86
5 13 788.00 20 14.63 1547 453 4.14 / 755.87 5 95
6 13 223.96 20 14.80 696 206 4.35 / 756.07 5 92
7 8 0.04 306 14.81 320 1450 5.80 / 757.52 5 142
Average= 68.87
(KJ/cycle)

Cycle 131 GMT 2/10/2022 15:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.72 32 14.80 496 235 0.23 / 746.12 5 29
2 3 1020.32 1 15.00 1916 29 0.26 / 746.15 5 7
3 7 2013.04 40 14.54 3270 1902 2.17 / 748.05 7 69
4 13 1924.08 20 14.50 3149 913 3.08 / 748.97 5 75
5 13 1394.00 20 14.52 2415 701 3.78 / 749.67 5 87
6 13 732.08 20 14.64 1474 432 4.21 / 750.10 5 94
7 13 185.44 20 14.82 634 188 4.40 / 750.29 5 91
8 8 0.12 306 14.82 316 1433 5.83 / 751.72 5 136
Average= 75.17
(KJ/cycle)

Cycle 130 GMT 22/ 9/2022 18:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.20 32 14.82 479 227 0.23 / 740.07 5 30
2 7 2011.24 40 14.55 3262 1898 2.13 / 741.97 30 69
3 13 1938.04 20 14.51 3180 923 3.05 / 742.89 5 74
4 13 1502.28 20 14.50 2566 744 3.79 / 743.64 5 84
5 13 941.68 20 14.58 1770 516 4.31 / 744.15 5 93
6 13 270.84 20 14.78 773 228 4.54 / 744.38 5 92
7 8 -0.08 317 14.81 321 1507 6.04 / 745.89 5 136
Average= 82.88
(KJ/cycle)

Cycle 129 GMT 12/ 9/2022 21:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.48 32 14.80 495 234 0.23 / 734.29 5 31
2 7 2004.32 40 14.55 3239 1885 2.12 / 736.18 31 71
3 13 1915.92 20 14.52 3125 907 3.03 / 737.08 5 74
4 13 1488.64 20 14.52 2536 736 3.76 / 737.82 5 85
5 13 635.12 20 14.69 1314 386 4.15 / 738.21 5 93
6 13 223.12 20 14.82 688 204 4.35 / 738.41 5 89
7 8 0.08 306 14.83 316 1434 5.79 / 739.84 5 132
Average= 92.48
(KJ/cycle)

Cycle 128 GMT 3/ 9/2022 0:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.96 32 14.82 496 235 0.24 / 728.38 6 29
2 7 2004.72 40 14.54 3251 1891 2.13 / 730.27 29 70
3 13 1911.80 20 14.51 3140 911 3.04 / 731.19 5 74
4 13 1476.16 20 14.51 2537 736 3.77 / 731.92 5 83
5 13 814.88 20 14.62 1587 464 4.24 / 732.39 5 94
6 13 232.72 20 14.80 711 210 4.45 / 732.60 5 92
7 8 0.04 308 14.81 320 1460 5.91 / 734.06 5 143
Average= 104.87
(KJ/cycle)

Cycle 127 GMT 24/ 8/2022 3:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.36 32 14.81 472 224 0.22 / 722.54 6 30
2 7 2005.76 40 14.55 3246 1889 2.11 / 724.43 30 69
3 13 1920.36 20 14.52 3140 912 3.02 / 725.34 5 73
4 13 1482.64 20 14.51 2546 739 3.76 / 726.08 5 85
5 13 730.00 20 14.65 1466 430 4.19 / 726.51 5 94
6 13 199.00 20 14.82 663 197 4.39 / 726.70 5 89
7 8 0.16 304 14.82 321 1446 5.84 / 728.15 5 142
Average= 121.36
(KJ/cycle)

Cycle 126 GMT 14/ 8/2022 6:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.84 32 14.82 477 226 0.23 / 716.75 6 29
2 7 2005.84 40 14.54 3252 1891 2.12 / 718.64 29 67
3 13 1925.96 20 14.52 3131 909 3.03 / 719.55 5 72
4 13 1401.56 20 14.53 2424 704 3.73 / 720.25 5 85
5 13 658.52 20 14.67 1347 395 4.13 / 720.65 5 93
6 13 240.36 20 14.80 729 216 4.34 / 720.86 5 91
7 8 0.12 308 14.82 318 1452 5.79 / 722.31 5 151
Average= 144.46
(KJ/cycle)

Cycle 125 GMT 4/ 8/2022 8:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.68 32 14.81 491 233 0.23 / 710.95 6 30
2 7 2012.76 40 14.54 3265 1899 2.13 / 712.85 30 71
3 13 1916.96 20 14.51 3151 914 3.05 / 713.76 5 74
4 13 1397.56 20 14.52 2421 703 3.75 / 714.46 5 85
5 13 660.20 20 14.68 1353 397 4.15 / 714.86 5 94
6 13 223.40 20 14.81 699 207 4.35 / 715.07 5 91
7 8 0.16 308 14.82 318 1452 5.80 / 716.52 5 133
Average= 179.13
(KJ/cycle)

Cycle 124 GMT 25/ 7/2022 11:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.80 32 14.83 495 235 0.23 / 705.16 6 23
2 7 2011.64 41 14.54 3254 1940 2.17 / 707.10 23 67
3 13 1932.80 20 14.51 3164 918 3.09 / 708.01 5 73
4 13 1202.64 20 14.56 2148 625 3.72 / 708.64 5 88
5 13 777.28 20 14.63 1531 448 4.17 / 709.09 5 93
6 13 216.92 20 14.81 691 205 4.37 / 709.29 5 91
7 8 0.00 300 14.82 320 1423 5.79 / 710.71 5 129
Average= 236.90
(KJ/cycle)

Cycle 123 GMT 15/ 7/2022 14:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.72 32 14.83 474 225 0.22 / 699.31 6 27
2 7 2003.40 40 14.56 3243 1889 2.11 / 701.20 27 69
3 13 1916.88 20 14.52 3143 913 3.03 / 702.11 5 73
4 13 1397.88 20 14.53 2416 702 3.73 / 702.82 5 87
5 13 845.56 20 14.62 1631 477 4.21 / 703.29 5 94
6 13 204.44 20 14.82 670 199 4.40 / 703.49 5 88
7 8 0.00 308 14.83 313 1430 5.83 / 704.92 5 134
Average= 352.46
(KJ/cycle)

Cycle 122 GMT 5/ 7/2022 17: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.96 32 14.82 481 228 0.23 / 693.53 6 29
2 7 2004.76 40 14.55 3238 1885 2.11 / 695.41 29 69
3 13 1912.68 20 14.52 3121 906 3.02 / 696.32 5 75
4 13 1480.68 20 14.51 2533 735 3.75 / 697.05 5 85
5 13 820.16 20 14.63 1592 466 4.22 / 697.52 5 95
6 13 173.80 20 14.84 613 182 4.40 / 697.70 5 89
7 8 0.04 300 14.83 312 1388 5.79 / 699.09 5 141
Average= 699.09
(KJ/cycle)

Cycle 120 GMT 15/ 6/2022 22:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 32 14.83 479 227 0.23 / 687.62 6 26
2 7 2012.16 40 14.54 3260 1896 2.12 / 689.52 26 68
3 13 1937.40 20 14.52 3166 919 3.04 / 690.43 5 75
4 13 1410.20 20 14.53 2432 707 3.75 / 691.14 5 86
5 13 950.24 20 14.59 1783 520 4.27 / 691.66 5 94
6 13 265.72 20 14.80 760 225 4.49 / 691.89 5 91
7 8 0.12 304 14.82 313 1410 5.90 / 693.30 5 131
Average= 5.73
(KJ/cycle)

Cycle 119 GMT 6/ 6/2022 1:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.16 32 14.82 492 233 0.23 / 681.80 6 24
2 7 2008.84 40 14.55 3249 1891 2.12 / 683.70 24 71
3 13 1926.32 20 14.52 3158 917 3.04 / 684.61 5 73
4 13 1407.20 20 14.53 2428 706 3.75 / 685.32 5 84
5 13 874.04 20 14.61 1675 489 4.24 / 685.81 5 91
6 13 215.48 20 14.82 684 203 4.44 / 686.01 5 89
7 13 24.88 20 14.88 369 110 4.55 / 686.12 5 80
8 8 0.00 274 14.83 313 1272 5.82 / 687.39 5 130
Average= 5.73
(KJ/cycle)

Cycle 118 GMT 27/ 5/2022 4:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.52 32 14.83 490 233 0.23 / 676.01 6 27
2 7 2011.52 41 14.55 3255 1942 2.17 / 677.95 27 71
3 13 1918.64 20 14.52 3148 914 3.09 / 678.86 5 75
4 13 1296.32 20 14.55 2282 664 3.75 / 679.53 5 88
5 13 766.76 20 14.64 1515 444 4.20 / 679.97 5 94
6 13 213.56 20 14.81 691 205 4.40 / 680.18 5 88
7 8 0.08 300 14.82 314 1396 5.80 / 681.57 5 139
Average= 5.73
(KJ/cycle)

Cycle 117 GMT 17/ 5/2022 7:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.36 32 14.83 488 232 0.23 / 670.20 6 20
2 7 2009.04 40 14.55 3261 1898 2.13 / 672.10 5 64
3 13 1925.08 20 14.52 3164 919 3.05 / 673.02 5 70
4 13 1486.32 20 14.52 2540 738 3.79 / 673.76 5 82
5 13 726.24 20 14.67 1459 428 4.21 / 674.18 5 91
6 13 183.16 20 14.84 638 189 4.40 / 674.37 5 88
7 8 0.20 297 14.83 318 1401 5.80 / 675.77 5 131
Average= 5.73
(KJ/cycle)

Cycle 116 GMT 7/ 5/2022 10:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.28 32 14.84 485 230 0.23 / 664.57 6 25
2 7 2004.20 40 14.56 3248 1892 2.12 / 666.46 25 68
3 13 1912.68 20 14.54 3130 910 3.03 / 667.37 5 74
4 13 1277.52 20 14.56 2249 655 3.69 / 668.02 5 88
5 13 648.80 20 14.69 1342 394 4.08 / 668.42 5 94
6 13 125.56 20 14.86 546 162 4.24 / 668.58 5 85
7 8 -0.08 293 14.83 320 1390 5.63 / 669.97 5 129
Average= 5.73
(KJ/cycle)

Cycle 115 GMT 27/ 4/2022 13: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.52 32 14.84 481 228 0.23 / 658.65 6 17
2 7 2008.52 41 14.55 3260 1945 2.17 / 660.59 17 66
3 13 1926.20 20 14.52 3156 917 3.09 / 661.51 5 73
4 13 1478.00 20 14.53 2534 736 3.83 / 662.25 5 83
5 13 910.48 20 14.61 1724 504 4.33 / 662.75 5 92
6 13 142.84 20 14.86 574 171 4.50 / 662.92 5 87
7 8 -0.04 300 14.84 318 1416 5.92 / 664.34 5 134
Average= 5.73
(KJ/cycle)

Cycle 114 GMT 17/ 4/2022 16: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.20 31 14.84 489 225 0.22 / 652.83 6 19
2 7 2004.48 41 14.56 3240 1934 2.16 / 654.76 5 65
3 13 1917.24 20 14.53 3144 914 3.07 / 655.68 5 73
4 13 1477.48 20 14.53 2535 737 3.81 / 656.41 5 83
5 13 726.52 20 14.68 1453 427 4.24 / 656.84 5 92
6 13 177.72 20 14.84 632 188 4.42 / 657.03 5 90
7 8 0.04 297 14.84 316 1393 5.82 / 658.42 5 147
Average= 5.73
(KJ/cycle)

Cycle 113 GMT 7/ 4/2022 18:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.92 31 14.85 467 215 0.21 / 647.01 6 21
2 7 2003.64 41 14.56 3249 1940 2.15 / 648.95 21 71
3 13 1905.92 20 14.53 3128 909 3.06 / 649.86 5 77
4 13 1361.56 20 14.55 2367 689 3.75 / 650.55 5 86
5 13 823.92 20 14.64 1606 470 4.22 / 651.02 5 95
6 13 148.08 20 14.86 582 173 4.40 / 651.19 5 90
7 8 0.04 300 14.84 317 1411 5.81 / 652.60 5 147
Average= 5.72
(KJ/cycle)

Cycle 112 GMT 28/ 3/2022 22: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.36 32 14.84 491 233 0.23 / 641.39 6 21
2 7 2004.04 41 14.56 3238 1933 2.17 / 643.32 21 68
3 13 1914.76 20 14.54 3131 910 3.08 / 644.23 5 74
4 13 1297.96 20 14.56 2274 662 3.74 / 644.89 5 86
5 13 751.92 20 14.66 1497 439 4.18 / 645.33 5 93
6 13 108.72 20 14.88 508 151 4.33 / 645.48 5 87
7 8 0.00 282 14.85 314 1315 5.64 / 646.80 5 129
Average= 5.72
(KJ/cycle)

Cycle 111 GMT 19/ 3/2022 0:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.60 32 14.85 476 226 0.23 / 635.42 6 25
2 7 2014.32 40 14.56 3265 1902 2.13 / 637.32 25 68
3 13 1925.88 20 14.53 3160 918 3.05 / 638.24 5 74
4 13 1610.40 20 14.50 2727 791 3.84 / 639.03 5 81
5 13 818.08 20 14.65 1592 466 4.30 / 639.49 5 94
6 13 264.04 20 14.82 763 226 4.53 / 639.72 5 91
7 8 -0.04 304 14.84 318 1435 5.96 / 641.15 5 131
Average= 5.72
(KJ/cycle)

Cycle 110 GMT 9/ 3/2022 3:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.24 32 14.85 484 230 0.23 / 629.63 6 26
2 7 2004.76 40 14.56 3246 1890 2.12 / 631.52 26 72
3 13 1913.72 20 14.54 3133 911 3.03 / 632.43 5 77
4 13 1292.20 20 14.57 2271 662 3.69 / 633.09 5 90
5 13 965.12 20 14.60 1807 528 4.22 / 633.62 5 95
6 13 163.32 20 14.85 604 179 4.40 / 633.80 5 91
7 8 -0.12 297 14.84 316 1393 5.79 / 635.19 5 136
Average= 5.72
(KJ/cycle)

Cycle 109 GMT 27/ 2/2022 6:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.04 32 14.85 467 222 0.22 / 623.86 6 20
2 7 2004.88 40 14.56 3245 1890 2.11 / 625.75 20 67
3 13 1915.60 20 14.54 3140 913 3.02 / 626.66 5 72
4 13 1494.16 20 14.53 2558 743 3.77 / 627.41 5 84
5 13 723.96 20 14.68 1447 425 4.19 / 627.83 5 94
6 13 173.44 20 14.85 620 184 4.38 / 628.02 5 92
7 8 0.08 297 14.85 313 1380 5.76 / 629.40 5 131
Average= 5.72
(KJ/cycle)

Cycle 108 GMT 17/ 2/2022 9:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.36 32 14.84 486 231 0.23 / 618.03 6 25
2 7 2005.84 40 14.57 3252 1895 2.13 / 619.93 25 70
3 13 1917.56 20 14.55 3132 911 3.04 / 620.84 5 74
4 13 1498.28 20 14.53 2557 743 3.78 / 621.58 5 85
5 13 719.56 20 14.69 1448 425 4.21 / 622.01 5 94
6 13 174.80 20 14.86 628 187 4.39 / 622.19 5 92
7 8 -0.08 308 14.85 316 1445 5.84 / 623.64 5 135
Average= 5.72
(KJ/cycle)

Cycle 107 GMT 7/ 2/2022 12:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.16 32 14.85 477 227 0.23 / 612.25 6 22
2 7 2008.44 40 14.56 3244 1889 2.12 / 614.14 22 68
3 13 1919.72 20 14.53 3152 916 3.03 / 615.06 5 72
4 13 1283.32 20 14.58 2252 657 3.69 / 615.71 5 87
5 13 750.52 20 14.67 1492 438 4.13 / 616.15 5 94
6 13 290.08 20 14.81 796 236 4.36 / 616.39 5 89
7 8 -0.04 304 14.85 313 1413 5.78 / 617.80 5 130
Average= 5.72
(KJ/cycle)

Cycle 106 GMT 28/ 1/2022 15: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.80 32 14.85 493 234 0.23 / 606.39 6 27
2 7 2004.00 40 14.57 3250 1894 2.13 / 608.28 27 69
3 13 1910.40 20 14.55 3137 913 3.04 / 609.20 5 77
4 13 1478.80 20 14.54 2540 739 3.78 / 609.93 5 85
5 13 831.88 20 14.66 1607 471 4.25 / 610.41 5 95
6 13 172.72 20 14.87 616 183 4.43 / 610.59 5 91
7 8 -0.04 304 14.86 318 1437 5.87 / 612.03 5 129
Average= 5.72
(KJ/cycle)

Cycle 105 GMT 18/ 1/2022 18: 5: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.12 32 14.85 489 232 0.23 / 600.59 6 28
2 7 2013.12 40 14.56 3255 1896 2.13 / 602.49 28 69
3 13 1929.12 20 14.54 3144 914 3.04 / 603.40 5 74
4 13 1384.44 20 14.56 2392 697 3.74 / 604.10 5 86
5 13 745.40 20 14.68 1484 436 4.17 / 604.53 5 95
6 13 199.84 20 14.86 650 193 4.37 / 604.73 5 88
7 8 0.08 304 14.85 316 1427 5.79 / 606.15 5 134
Average= 5.72
(KJ/cycle)

Cycle 104 GMT 8/ 1/2022 20:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.76 32 14.85 492 234 0.23 / 594.72 6 26
2 7 2006.20 41 14.56 3254 1943 2.18 / 596.67 26 68
3 13 1914.16 20 14.54 3127 909 3.09 / 597.58 5 74
4 13 1583.60 20 14.53 2677 778 3.86 / 598.35 5 82
5 13 702.28 20 14.70 1409 414 4.28 / 598.77 5 95
6 13 164.28 20 14.88 597 178 4.46 / 598.95 5 91
7 8 0.08 304 14.86 313 1414 5.87 / 600.36 5 139
Average= 5.72
(KJ/cycle)

Cycle 103 GMT 29/12/2021 23:41: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.56 32 14.85 488 232 0.23 / 588.93 6 31
2 7 2009.48 40 14.57 3253 1896 2.13 / 590.82 31 69
3 13 1923.24 20 14.54 3154 917 3.04 / 591.74 5 74
4 13 1376.76 20 14.56 2390 696 3.74 / 592.44 5 87
5 13 734.48 20 14.69 1466 431 4.17 / 592.87 5 97
6 13 196.64 20 14.85 661 196 4.37 / 593.06 5 92
7 8 0.04 302 14.86 318 1427 5.80 / 594.49 5 134
Average= 5.72
(KJ/cycle)

Cycle 102 GMT 20/12/2021 2:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.44 32 14.85 490 233 0.23 / 583.04 6 31
2 7 2008.00 40 14.57 3248 1893 2.13 / 584.93 31 72
3 13 1910.32 20 14.55 3112 906 3.03 / 585.84 5 75
4 13 1481.56 20 14.54 2543 740 3.77 / 586.58 5 85
5 13 929.80 20 14.62 1754 513 4.28 / 587.09 5 95
6 13 165.96 20 14.87 601 179 4.46 / 587.27 5 90
7 8 0.04 304 14.86 316 1428 5.89 / 588.70 5 130
Average= 5.72
(KJ/cycle)

Cycle 101 GMT 10/12/2021 5:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.04 32 14.85 476 226 0.23 / 577.14 6 33
2 7 2007.12 41 14.56 3256 1944 2.17 / 579.08 33 71
3 13 1925.28 20 14.54 3157 918 3.09 / 580.00 5 75
4 13 1399.36 20 14.55 2421 705 3.79 / 580.71 5 86
5 13 844.36 20 14.65 1626 476 4.27 / 581.18 5 95
6 13 173.36 20 14.86 626 186 4.45 / 581.37 5 91
7 8 -0.04 302 14.86 320 1436 5.89 / 582.81 5 129
Average= 5.71
(KJ/cycle)

Cycle 100 GMT 30/11/2021 8: 2: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.20 32 14.86 499 237 0.24 / 571.31 6 26
2 7 2005.56 40 14.57 3252 1895 2.13 / 573.21 26 68
3 13 1923.12 20 14.55 3150 917 3.05 / 574.13 5 74
4 13 1388.96 20 14.55 2404 700 3.75 / 574.83 5 85
5 13 846.36 20 14.65 1632 478 4.23 / 575.30 5 93
6 13 163.20 20 14.87 602 179 4.41 / 575.48 5 90
7 8 0.00 304 14.86 317 1432 5.84 / 576.91 5 133
Average= 5.71
(KJ/cycle)

Cycle 99 GMT 20/11/2021 10:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.16 31 14.86 496 228 0.23 / 565.61 6 27
2 7 2005.20 40 14.58 3249 1895 2.12 / 567.51 27 66
3 13 1918.08 20 14.55 3133 912 3.04 / 568.42 5 73
4 13 1203.20 20 14.60 2134 623 3.66 / 569.04 5 88
5 13 791.16 20 14.67 1547 454 4.11 / 569.50 5 94
6 13 144.24 20 14.88 573 171 4.28 / 569.67 5 89
7 8 -0.08 300 14.86 316 1409 5.69 / 571.08 5 134
Average= 5.71
(KJ/cycle)

Cycle 98 GMT 10/11/2021 13:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.28 32 14.86 494 235 0.23 / 559.82 6 33
2 7 2013.44 40 14.58 3247 1894 2.13 / 561.71 33 71
3 13 1922.12 20 14.55 3131 911 3.04 / 562.63 5 76
4 13 1397.52 20 14.56 2415 703 3.74 / 563.33 5 88
5 13 763.52 20 14.69 1506 442 4.19 / 563.77 5 95
6 13 217.32 20 14.86 688 204 4.39 / 563.98 5 91
7 8 0.16 302 14.87 314 1410 5.80 / 565.39 5 136
Average= 5.71
(KJ/cycle)

Cycle 97 GMT 31/10/2021 16:10:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.84 32 14.86 492 234 0.23 / 554.03 6 34
2 7 2008.44 40 14.57 3255 1897 2.13 / 555.93 34 72
3 13 1927.12 20 14.54 3168 921 3.05 / 556.85 5 75
4 13 1395.44 20 14.57 2421 705 3.76 / 557.55 5 88
5 13 733.44 20 14.70 1471 432 4.19 / 557.99 5 96
6 13 197.00 20 14.87 654 194 4.38 / 558.18 5 91
7 8 0.00 295 14.87 320 1404 5.79 / 559.59 5 131
Average= 5.71
(KJ/cycle)

Cycle 96 GMT 21/10/2021 18:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.92 31 14.85 499 230 0.23 / 548.17 5 31
2 7 2005.52 40 14.59 3245 1894 2.12 / 550.07 31 70
3 13 1915.88 20 14.54 3142 914 3.04 / 550.98 5 77
4 13 1463.76 20 14.56 2505 729 3.77 / 551.71 5 86
5 13 707.16 20 14.71 1429 420 4.19 / 552.13 5 96
6 13 256.20 20 14.85 749 222 4.41 / 552.35 5 92
7 8 0.12 306 14.87 317 1442 5.85 / 553.80 5 136
Average= 5.71
(KJ/cycle)

Cycle 95 GMT 11/10/2021 22: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.44 31 14.86 489 225 0.23 / 542.33 5 31
2 7 2004.60 41 14.57 3249 1941 2.17 / 544.28 31 71
3 13 1909.20 20 14.55 3130 911 3.08 / 545.19 5 74
4 13 1381.36 20 14.57 2394 698 3.77 / 545.88 5 89
5 13 717.76 20 14.70 1452 427 4.20 / 546.31 5 96
6 13 168.44 20 14.88 621 185 4.39 / 546.50 5 89
7 8 0.04 300 14.87 325 1450 5.84 / 547.95 5 134
Average= 5.71
(KJ/cycle)

Cycle 94 GMT 2/10/2021 0:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.92 32 14.86 494 235 0.23 / 536.53 6 30
2 7 2006.00 40 14.59 3239 1890 2.13 / 538.42 30 67
3 13 1921.76 20 14.56 3139 914 3.04 / 539.33 5 77
4 13 1395.64 20 14.57 2412 703 3.74 / 540.03 5 86
5 13 750.84 20 14.70 1492 439 4.18 / 540.47 5 96
6 13 203.76 20 14.87 672 200 4.38 / 540.67 5 92
7 8 0.04 304 14.87 318 1438 5.82 / 542.11 5 132
Average= 5.71
(KJ/cycle)

Cycle 93 GMT 22/ 9/2021 3:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.60 32 14.86 497 236 0.24 / 530.64 6 34
2 7 2012.20 40 14.58 3250 1895 2.13 / 532.54 34 71
3 13 1930.52 20 14.55 3160 920 3.05 / 533.45 5 78
4 13 1400.12 20 14.57 2418 705 3.76 / 534.16 5 88
5 13 951.72 20 14.63 1783 522 4.28 / 534.68 5 96
6 13 169.60 20 14.89 609 181 4.46 / 534.86 5 89
7 8 0.04 304 14.87 316 1428 5.89 / 536.29 5 142
Average= 5.71
(KJ/cycle)

Cycle 92 GMT 12/ 9/2021 6:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.52 32 14.86 497 236 0.24 / 524.82 6 34
2 7 2005.44 40 14.58 3243 1891 2.13 / 526.71 34 71
3 13 1918.64 20 14.55 3148 916 3.04 / 527.63 5 77
4 13 1395.08 20 14.56 2408 701 3.74 / 528.33 5 90
5 13 851.32 20 14.66 1633 479 4.22 / 528.81 5 96
6 13 177.88 20 14.88 632 188 4.41 / 529.00 5 91
7 8 0.00 295 14.87 321 1408 5.82 / 530.40 5 130
Average= 5.70
(KJ/cycle)

Cycle 91 GMT 2/ 9/2021 9: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.64 32 14.87 498 237 0.24 / 519.01 6 25
2 7 2014.52 40 14.58 3254 1898 2.13 / 520.91 25 69
3 13 1930.44 20 14.55 3166 921 3.06 / 521.83 5 74
4 13 1407.48 20 14.56 2432 708 3.76 / 522.54 5 86
5 13 764.92 20 14.69 1513 445 4.21 / 522.98 5 94
6 13 214.44 20 14.87 677 201 4.41 / 523.18 5 92
7 8 0.08 297 14.87 317 1400 5.81 / 524.58 5 130
Average= 5.70
(KJ/cycle)

Cycle 90 GMT 23/ 8/2021 11:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.16 31 14.87 497 229 0.23 / 513.27 6 32
2 7 2005.28 40 14.57 3256 1898 2.13 / 515.17 32 71
3 13 1909.52 20 14.55 3130 911 3.04 / 516.08 5 77
4 13 1280.52 20 14.60 2260 660 3.70 / 516.74 5 89
5 13 754.64 20 14.70 1500 441 4.14 / 517.18 5 94
6 13 112.12 20 14.91 524 156 4.29 / 517.34 5 85
7 8 0.08 300 14.88 321 1433 5.73 / 518.77 5 137
Average= 5.70
(KJ/cycle)

Cycle 89 GMT 13/ 8/2021 14:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.88 31 14.88 489 226 0.23 / 507.49 6 28
2 7 2013.04 40 14.58 3259 1901 2.13 / 509.39 28 69
3 13 1920.52 20 14.55 3147 916 3.04 / 510.31 5 74
4 13 1393.08 20 14.57 2417 704 3.75 / 511.01 5 85
5 13 844.96 20 14.67 1632 479 4.23 / 511.49 5 94
6 13 185.64 20 14.88 635 189 4.41 / 511.68 5 89
7 8 -0.04 291 14.88 315 1364 5.78 / 513.05 5 131
Average= 5.70
(KJ/cycle)

Cycle 88 GMT 3/ 8/2021 17: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.56 31 14.86 491 226 0.23 / 501.72 6 31
2 7 2007.12 40 14.59 3253 1898 2.12 / 503.61 5 71
3 13 1929.16 20 14.56 3167 922 3.05 / 504.54 5 75
4 13 1411.20 20 14.57 2441 711 3.76 / 505.25 5 88
5 13 756.84 20 14.71 1501 442 4.20 / 505.69 5 96
6 13 127.28 20 14.91 544 162 4.36 / 505.85 5 86
7 8 0.04 300 14.89 317 1416 5.78 / 507.27 5 139
Average= 5.70
(KJ/cycle)

Cycle 87 GMT 24/ 7/2021 19:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.36 31 14.88 474 219 0.22 / 495.96 6 28
2 7 2011.16 40 14.58 3269 1906 2.13 / 497.87 28 72
3 13 1925.40 20 14.55 3160 920 3.04 / 498.79 5 74
4 13 1300.40 20 14.59 2273 663 3.71 / 499.45 5 89
5 13 766.40 20 14.69 1516 445 4.15 / 499.90 5 96
6 13 207.64 20 14.87 667 198 4.35 / 500.10 5 94
7 8 0.04 300 14.87 312 1392 5.74 / 501.49 5 137
Average= 5.70
(KJ/cycle)

Cycle 86 GMT 14/ 7/2021 22:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.04 31 14.88 472 218 0.22 / 489.99 6 29
2 7 2004.76 41 14.59 3241 1939 2.16 / 491.93 29 70
3 13 1918.04 20 14.55 3147 916 3.07 / 492.84 5 75
4 13 1590.88 20 14.54 2682 780 3.85 / 493.62 5 84
5 13 1026.20 20 14.62 1895 554 4.41 / 494.18 5 93
6 13 132.96 20 14.91 556 166 4.57 / 494.34 5 88
7 8 0.04 302 14.89 312 1403 5.98 / 495.75 5 132
Average= 5.70
(KJ/cycle)

Cycle 85 GMT 5/ 7/2021 1:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.28 31 14.88 483 223 0.22 / 484.25 6 24
2 7 2003.00 40 14.59 3241 1891 2.11 / 486.15 24 68
3 13 1912.20 20 14.56 3138 914 3.03 / 487.06 5 74
4 13 1386.60 20 14.59 2399 700 3.73 / 487.76 5 86
5 13 743.68 20 14.72 1470 433 4.16 / 488.19 5 95
6 13 194.04 20 14.89 653 194 4.36 / 488.39 5 94
7 8 0.00 300 14.89 310 1385 5.74 / 489.77 5 136
Average= 5.70
(KJ/cycle)

Cycle 84 GMT 25/ 6/2021 4:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.00 31 14.88 483 223 0.22 / 478.43 6 28
2 7 2014.04 40 14.59 3258 1901 2.12 / 480.33 28 71
3 13 1926.76 20 14.56 3152 918 3.04 / 481.25 5 76
4 13 1486.96 20 14.56 2557 745 3.79 / 481.99 5 87
5 13 707.32 20 14.73 1426 420 4.21 / 482.41 5 97
6 13 162.64 20 14.90 594 177 4.38 / 482.59 5 92
7 8 0.00 306 14.89 316 1440 5.82 / 484.03 5 141
Average= 5.69
(KJ/cycle)

Cycle 83 GMT 15/ 6/2021 7:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.28 31 14.87 477 220 0.22 / 472.75 6 22
2 7 2006.08 40 14.59 3244 1893 2.11 / 474.64 22 69
3 13 1919.48 20 14.56 3147 916 3.03 / 475.56 5 74
4 13 1273.72 20 14.61 2232 652 3.68 / 476.21 5 88
5 13 641.04 20 14.75 1321 390 4.07 / 476.60 5 95
6 13 206.24 20 14.88 654 195 4.27 / 476.80 5 84
7 13 43.80 20 14.93 399 119 4.39 / 476.92 5 87
8 8 0.04 278 14.88 312 1291 5.68 / 478.21 5 135
Average= 5.69
(KJ/cycle)

Cycle 82 GMT 5/ 6/2021 10:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.00 31 14.89 493 228 0.23 / 466.89 6 27
2 7 2004.16 40 14.59 3246 1894 2.12 / 468.78 5 71
3 13 1920.76 20 14.57 3150 918 3.04 / 469.70 5 77
4 13 1468.60 20 14.57 2515 733 3.77 / 470.43 5 87
5 13 811.04 20 14.70 1575 463 4.24 / 470.90 5 97
6 13 235.96 20 14.87 722 215 4.45 / 471.11 5 92
7 8 0.08 302 14.89 316 1421 5.87 / 472.53 5 138
Average= 5.69
(KJ/cycle)

Cycle 81 GMT 26/ 5/2021 13:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.60 31 14.89 485 224 0.22 / 460.96 6 22
2 7 2009.04 40 14.59 3248 1896 2.12 / 462.86 22 69
3 13 1929.72 20 14.56 3158 920 3.04 / 463.78 5 75
4 13 1837.20 20 14.50 3049 884 3.92 / 464.66 5 78
5 13 793.68 20 14.71 1555 457 4.38 / 465.12 5 94
6 13 165.00 20 14.91 611 182 4.56 / 465.30 5 89
7 8 0.00 289 14.90 316 1361 5.92 / 466.66 5 129
Average= 5.69
(KJ/cycle)

Cycle 80 GMT 16/ 5/2021 15:56: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.56 31 14.89 493 228 0.23 / 455.30 6 26
2 7 2015.16 40 14.58 3270 1907 2.13 / 457.21 26 72
3 13 1924.84 20 14.56 3153 918 3.05 / 458.13 5 78
4 13 1296.08 20 14.60 2282 666 3.72 / 458.80 5 90
5 13 657.08 20 14.74 1353 399 4.12 / 459.19 5 95
6 13 134.88 20 14.91 560 167 4.28 / 459.36 5 87
7 8 0.08 293 14.90 315 1375 5.66 / 460.74 5 143
Average= 5.69
(KJ/cycle)

Cycle 79 GMT 6/ 5/2021 18:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.00 31 14.88 488 225 0.23 / 449.58 6 26
2 7 2004.08 40 14.59 3254 1899 2.12 / 451.48 5 69
3 13 1920.44 20 14.57 3149 918 3.04 / 452.40 5 75
4 13 1494.04 20 14.56 2559 745 3.79 / 453.14 5 86
5 13 668.72 20 14.75 1373 405 4.19 / 453.55 5 94
6 13 130.84 20 14.92 555 166 4.36 / 453.71 5 88
7 8 0.08 289 14.90 317 1365 5.72 / 455.08 5 130
Average= 5.69
(KJ/cycle)

Cycle 78 GMT 26/ 4/2021 21:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.32 31 14.88 482 222 0.22 / 443.81 6 26
2 7 2007.80 41 14.59 3254 1947 2.17 / 445.76 26 71
3 13 1803.84 20 14.58 2992 872 3.04 / 446.63 5 78
4 13 1281.24 20 14.61 2262 661 3.70 / 447.29 5 90
5 13 744.96 20 14.72 1481 436 4.14 / 447.73 5 95
6 13 202.76 20 14.89 662 197 4.34 / 447.92 5 86
7 8 0.04 300 14.89 320 1429 5.76 / 449.35 5 129
Average= 5.69
(KJ/cycle)

Cycle 77 GMT 16/ 4/2021 23:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.52 31 14.89 475 219 0.22 / 437.91 6 20
2 7 2012.96 40 14.60 3257 1902 2.12 / 439.81 20 69
3 13 1922.84 20 14.57 3152 918 3.04 / 440.73 5 74
4 13 1494.88 20 14.57 2557 745 3.78 / 441.48 5 84
5 13 840.16 20 14.69 1619 476 4.26 / 441.95 5 93
6 13 278.04 20 14.86 776 231 4.49 / 442.18 5 89
7 8 0.04 300 14.89 315 1407 5.90 / 443.59 5 134
Average= 5.69
(KJ/cycle)

Cycle 76 GMT 7/ 4/2021 2:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.60 31 14.90 477 220 0.22 / 432.20 6 27
2 7 2003.92 40 14.60 3252 1899 2.12 / 434.10 27 72
3 13 1914.96 20 14.58 3135 914 3.03 / 435.01 5 77
4 13 1369.80 20 14.59 2373 692 3.73 / 435.70 5 88
5 13 708.88 20 14.74 1423 420 4.15 / 436.12 5 95
6 13 163.92 20 14.91 604 180 4.33 / 436.30 5 89
7 8 0.00 295 14.90 316 1389 5.71 / 437.69 5 136
Average= 5.68
(KJ/cycle)

Cycle 75 GMT 28/ 3/2021 5:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.52 31 14.88 473 218 0.22 / 426.47 6 26
2 7 2003.84 41 14.60 3252 1947 2.16 / 428.42 26 70
3 13 1908.96 20 14.58 3137 915 3.08 / 429.33 5 76
4 13 1474.68 20 14.58 2527 737 3.82 / 430.07 5 86
5 13 796.20 20 14.71 1558 458 4.27 / 430.53 5 95
6 13 130.44 20 14.93 549 164 4.44 / 430.69 5 88
7 8 0.16 274 14.91 314 1283 5.72 / 431.98 5 132
Average= 5.68
(KJ/cycle)

Cycle 74 GMT 18/ 3/2021 8:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.48 31 14.90 485 224 0.22 / 420.64 6 21
2 7 2009.32 40 14.59 3269 1908 2.13 / 422.55 21 68
3 13 1916.76 20 14.57 3156 920 3.05 / 423.47 5 74
4 13 1482.16 20 14.58 2541 741 3.79 / 424.21 5 85
5 13 830.80 20 14.70 1611 474 4.27 / 424.68 5 94
6 13 162.04 20 14.91 600 179 4.44 / 424.86 5 85
7 8 0.00 295 14.90 317 1393 5.84 / 426.25 5 135
Average= 5.68
(KJ/cycle)

Cycle 73 GMT 8/ 3/2021 11:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.44 31 14.90 483 223 0.22 / 414.88 6 23
2 7 2007.44 40 14.61 3262 1906 2.13 / 416.79 23 68
3 13 1924.52 20 14.58 3158 921 3.05 / 417.71 5 74
4 13 1395.36 20 14.60 2424 708 3.76 / 418.42 5 86
5 13 644.36 20 14.76 1347 398 4.16 / 418.82 5 94
6 13 216.12 20 14.89 688 205 4.36 / 419.02 5 92
7 8 0.00 297 14.90 315 1394 5.75 / 420.42 5 133
Average= 5.68
(KJ/cycle)

Cycle 72 GMT 26/ 2/2021 14:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.24 31 14.90 499 230 0.23 / 408.96 6 28
2 7 2013.12 40 14.60 3273 1911 2.14 / 410.87 28 72
3 13 1915.84 20 14.58 3144 917 3.06 / 411.79 5 77
4 13 1477.32 20 14.59 2528 738 3.80 / 412.53 5 87
5 13 924.12 20 14.68 1749 514 4.31 / 413.04 5 96
6 13 247.92 20 14.89 733 218 4.53 / 413.26 5 93
7 8 0.04 297 14.91 317 1404 5.93 / 414.66 5 132
Average= 5.68
(KJ/cycle)

Cycle 71 GMT 16/ 2/2021 17: 5: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.72 31 14.89 494 228 0.23 / 403.08 6 29
2 7 2007.24 40 14.61 3263 1907 2.13 / 404.98 29 70
3 13 1925.76 20 14.58 3159 921 3.06 / 405.90 5 76
4 13 1481.24 20 14.59 2534 739 3.80 / 406.64 5 87
5 13 812.44 20 14.71 1583 466 4.26 / 407.11 5 96
6 13 249.32 20 14.89 742 221 4.48 / 407.33 5 90
7 8 0.08 295 14.91 318 1399 5.88 / 408.73 5 129
Average= 5.68
(KJ/cycle)

Cycle 70 GMT 6/ 2/2021 20: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.68 31 14.89 498 230 0.23 / 397.20 6 23
2 7 2005.52 40 14.61 3259 1905 2.13 / 399.10 23 69
3 13 1917.32 20 14.59 3149 919 3.05 / 400.02 5 75
4 13 1302.88 20 14.63 2279 667 3.72 / 400.69 5 88
5 13 878.08 20 14.69 1678 493 4.21 / 401.18 5 95
6 13 309.20 20 14.86 827 246 4.46 / 401.43 5 91
7 8 -0.08 300 14.90 318 1421 5.88 / 402.85 5 133
Average= 5.67
(KJ/cycle)

Cycle 69 GMT 27/ 1/2021 22:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.36 31 14.90 502 232 0.23 / 391.40 6 30
2 7 2007.24 40 14.61 3260 1905 2.14 / 393.30 30 71
3 13 1924.04 20 14.59 3160 922 3.06 / 394.23 5 76
4 13 1288.32 20 14.63 2275 666 3.72 / 394.89 5 90
5 13 750.88 20 14.73 1500 442 4.17 / 395.33 5 97
6 13 194.84 20 14.91 645 192 4.36 / 395.53 5 87
7 8 0.08 304 14.91 318 1441 5.80 / 396.97 5 141
Average= 5.67
(KJ/cycle)

Cycle 68 GMT 18/ 1/2021 1:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.60 31 14.90 497 230 0.23 / 385.64 6 32
2 7 2014.76 40 14.61 3279 1916 2.15 / 387.56 32 72
3 13 1932.28 20 14.58 3170 924 3.07 / 388.48 5 78
4 13 1299.56 20 14.63 2292 671 3.74 / 389.15 5 90
5 13 573.00 20 14.80 1232 365 4.11 / 389.52 5 96
6 13 255.96 20 14.89 755 225 4.33 / 389.74 5 94
7 8 -0.08 297 14.91 322 1426 5.76 / 391.17 5 131
Average= 5.67
(KJ/cycle)

Cycle 67 GMT 8/ 1/2021 4:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.96 31 14.89 501 231 0.23 / 379.77 6 28
2 7 2015.40 40 14.62 3276 1916 2.15 / 381.68 28 68
3 13 1928.56 20 14.59 3155 921 3.07 / 382.60 5 74
4 13 1394.44 20 14.61 2426 709 3.78 / 383.31 5 86
5 13 832.32 20 14.72 1613 475 4.25 / 383.79 5 94
6 13 173.00 20 14.93 620 185 4.44 / 383.97 5 87
7 8 0.20 300 14.92 322 1441 5.88 / 385.41 5 140
Average= 5.67
(KJ/cycle)

Cycle 66 GMT 29/12/2020 7:17: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.92 31 14.92 507 234 0.23 / 374.00 6 32
2 7 2005.24 40 14.61 3250 1899 2.13 / 375.90 32 73
3 13 1914.32 20 14.59 3144 917 3.05 / 376.81 5 78
4 13 1183.48 20 14.66 2118 621 3.67 / 377.43 5 91
5 13 762.72 20 14.74 1511 445 4.12 / 377.88 5 96
6 13 205.92 20 14.92 674 201 4.32 / 378.08 5 93
7 8 0.00 300 14.91 325 1454 5.77 / 379.53 5 141
Average= 5.66
(KJ/cycle)

Cycle 65 GMT 19/12/2020 10: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.56 31 14.92 499 231 0.23 / 368.17 6 32
2 7 2004.36 40 14.63 3254 1904 2.14 / 370.08 32 72
3 13 1913.16 20 14.61 3142 918 3.05 / 371.00 5 77
4 13 1460.56 20 14.61 2503 731 3.78 / 371.73 5 87
5 13 791.32 20 14.74 1551 457 4.24 / 372.19 5 96
6 13 131.76 20 14.95 558 167 4.41 / 372.35 5 89
7 8 0.08 293 14.93 322 1409 5.82 / 373.76 5 132
Average= 5.66
(KJ/cycle)

Cycle 64 GMT 9/12/2020 13: 3:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.80 31 14.91 504 233 0.23 / 362.40 6 31
2 7 2014.00 40 14.61 3266 1909 2.14 / 364.31 31 71
3 13 1923.96 20 14.60 3151 920 3.06 / 365.23 5 76
4 13 1299.56 20 14.64 2278 667 3.73 / 365.90 5 89
5 13 862.28 20 14.72 1653 487 4.22 / 366.38 5 96
6 13 89.84 20 14.97 486 146 4.36 / 366.53 5 83
7 8 0.12 295 14.93 321 1414 5.77 / 367.94 5 138
Average= 5.66
(KJ/cycle)

Cycle 63 GMT 29/11/2020 15:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.00 31 14.93 497 230 0.23 / 356.63 6 31
2 7 2014.56 40 14.62 3269 1912 2.14 / 358.54 31 71
3 13 1924.84 20 14.59 3172 926 3.07 / 359.47 5 76
4 13 1302.88 20 14.64 2285 669 3.74 / 360.13 5 90
5 13 655.20 20 14.79 1358 402 4.14 / 360.54 5 96
6 13 202.68 20 14.93 669 200 4.34 / 360.74 5 93
7 8 0.08 302 14.93 318 1434 5.77 / 362.17 5 146
Average= 5.66
(KJ/cycle)

Cycle 62 GMT 19/11/2020 18:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.92 31 14.93 502 232 0.23 / 350.88 6 34
2 7 2006.56 40 14.63 3250 1902 2.13 / 352.78 34 73
3 13 1914.32 20 14.60 3140 917 3.05 / 353.70 5 78
4 13 1382.48 20 14.63 2402 703 3.75 / 354.40 5 89
5 13 736.88 20 14.77 1473 435 4.19 / 354.84 5 97
6 13 102.76 20 14.98 504 151 4.34 / 354.99 5 86
7 8 0.04 295 14.95 320 1411 5.75 / 356.40 5 133
Average= 5.66
(KJ/cycle)

Cycle 61 GMT 9/11/2020 21:18:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.80 31 14.93 494 229 0.23 / 345.00 6 33
2 7 2010.20 41 14.62 3265 1957 2.19 / 346.96 33 72
3 13 1916.96 20 14.60 3147 919 3.10 / 347.88 5 76
4 13 1587.48 20 14.59 2710 791 3.90 / 348.67 5 85
5 13 672.40 20 14.80 1384 410 4.31 / 349.08 5 96
6 13 123.24 20 14.98 537 161 4.47 / 349.24 5 88
7 8 0.08 291 14.95 324 1410 5.88 / 350.65 5 132
Average= 5.66
(KJ/cycle)

Cycle 60 GMT 31/10/2020 0:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.84 31 14.95 493 228 0.23 / 339.12 6 32
2 7 2010.48 40 14.63 3270 1914 2.14 / 341.04 32 71
3 13 1925.36 20 14.61 3180 929 3.07 / 341.96 5 76
4 13 1301.48 20 14.65 2288 670 3.74 / 342.63 5 90
5 13 762.40 20 14.77 1512 447 4.19 / 343.08 5 96
6 13 207.32 20 14.94 668 200 4.39 / 343.28 5 86
7 8 0.04 305 14.94 327 1490 5.88 / 344.77 5 137
Average= 5.65
(KJ/cycle)

Cycle 59 GMT 21/10/2020 2:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.60 31 14.94 503 233 0.23 / 333.32 6 32
2 7 2013.84 40 14.63 3264 1910 2.14 / 335.23 32 72
3 13 1927.76 20 14.61 3165 925 3.07 / 336.15 5 77
4 13 1386.04 20 14.64 2413 707 3.77 / 336.86 5 89
5 13 737.64 20 14.79 1484 439 4.21 / 337.30 5 97
6 13 96.48 20 15.00 502 151 4.36 / 337.45 5 86
7 8 -0.04 296 14.96 326 1444 5.81 / 338.89 5 140
Average= 5.65
(KJ/cycle)

Cycle 58 GMT 11/10/2020 5:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.88 31 14.95 511 237 0.24 / 327.59 6 32
2 7 2012.76 40 14.64 3277 1919 2.16 / 329.51 32 72
3 13 1914.76 20 14.62 3148 920 3.08 / 330.43 5 77
4 13 1288.36 20 14.67 2278 668 3.74 / 331.10 5 90
5 13 649.04 20 14.83 1352 401 4.15 / 331.50 5 97
6 13 114.36 20 15.00 525 157 4.30 / 331.66 5 87
7 8 0.04 295 14.97 323 1426 5.73 / 333.09 5 134
Average= 5.65
(KJ/cycle)

Cycle 57 GMT 1/10/2020 8:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.52 31 14.95 510 236 0.24 / 321.67 6 34
2 7 2010.92 40 14.65 3270 1916 2.15 / 323.59 34 71
3 13 1919.96 20 14.62 3158 923 3.08 / 324.51 5 77
4 13 1398.92 20 14.65 2431 712 3.79 / 325.22 5 89
5 13 735.20 20 14.80 1475 437 4.22 / 325.66 5 97
6 13 186.44 20 14.97 650 195 4.42 / 325.85 5 92
7 8 0.00 305 14.97 329 1502 5.92 / 327.36 5 147
Average= 5.64
(KJ/cycle)

Cycle 56 GMT 21/ 9/2020 11: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.12 31 14.97 507 235 0.24 / 315.72 6 29
2 7 2011.96 40 14.64 3272 1916 2.15 / 317.64 29 69
3 13 1917.84 20 14.62 3140 918 3.07 / 318.56 5 75
4 13 1482.24 20 14.63 2544 744 3.81 / 319.30 5 86
5 13 601.64 20 14.85 1294 384 4.20 / 319.68 5 95
6 13 381.48 20 14.91 944 282 4.48 / 319.97 5 94
7 8 0.04 297 14.98 330 1468 5.95 / 321.43 5 134
Average= 5.64
(KJ/cycle)

Cycle 55 GMT 11/ 9/2020 13:55:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.68 31 14.98 507 235 0.24 / 309.86 6 36
2 7 2004.96 40 14.65 3258 1909 2.14 / 311.77 36 73
3 13 1915.32 20 14.63 3140 919 3.06 / 312.69 5 76
4 13 1381.16 20 14.67 2398 704 3.77 / 313.39 5 89
5 13 706.64 20 14.83 1433 425 4.19 / 313.81 5 97
6 13 163.00 20 15.00 614 184 4.38 / 314.00 5 90
7 13 28.32 20 15.04 392 118 4.49 / 314.12 5 83
8 8 0.00 278 14.98 329 1370 5.86 / 315.49 5 131
Average= 5.63
(KJ/cycle)

Cycle 54 GMT 1/ 9/2020 16:56: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.72 31 14.99 511 237 0.24 / 304.06 6 34
2 7 2003.80 40 14.66 3252 1907 2.14 / 305.97 34 74
3 13 1818.60 20 14.65 3013 883 3.03 / 306.85 5 80
4 13 1395.60 20 14.66 2431 713 3.74 / 307.57 5 89
5 13 727.08 20 14.82 1457 432 4.17 / 308.00 5 97
6 13 182.40 20 15.00 641 192 4.36 / 308.19 5 91
7 8 0.04 293 15.00 326 1433 5.80 / 309.62 5 135
Average= 5.63
(KJ/cycle)

Cycle 53 GMT 22/ 8/2020 19:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.52 31 14.99 514 239 0.24 / 298.34 6 27
2 7 2003.64 40 14.66 3260 1912 2.15 / 300.26 5 70
3 13 1905.44 20 14.64 3117 913 3.06 / 301.17 5 75
4 13 1277.12 20 14.70 2261 665 3.73 / 301.83 5 89
5 13 641.20 20 14.86 1337 397 4.13 / 302.23 5 95
6 13 101.96 20 15.04 513 154 4.28 / 302.38 5 88
7 8 0.00 291 15.00 330 1440 5.72 / 303.83 5 132
Average= 5.63
(KJ/cycle)

Cycle 52 GMT 12/ 8/2020 22:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.04 31 15.00 494 230 0.23 / 292.31 6 31
2 7 2004.48 40 14.67 3245 1904 2.13 / 294.22 31 72
3 13 1913.84 20 14.64 3136 918 3.05 / 295.13 5 78
4 13 1477.00 20 14.66 2540 745 3.80 / 295.88 5 87
5 13 886.32 20 14.79 1692 500 4.30 / 296.38 5 97
6 13 204.96 20 15.01 681 204 4.50 / 296.58 5 92
7 8 0.08 310 15.01 327 1522 6.02 / 298.11 5 142
Average= 5.62
(KJ/cycle)

Cycle 51 GMT 3/ 8/2020 1:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.12 31 15.01 501 233 0.23 / 286.61 6 29
2 7 2011.08 41 14.65 3265 1961 2.19 / 288.57 29 71
3 13 1816.00 20 14.66 3003 880 3.07 / 289.45 5 79
4 13 1380.48 20 14.68 2393 703 3.78 / 290.15 5 89
5 13 528.20 20 14.92 1166 348 4.13 / 290.50 5 92
6 13 112.16 20 15.05 532 160 4.29 / 290.66 5 89
7 8 0.04 289 15.02 328 1424 5.71 / 292.08 5 129
Average= 5.62
(KJ/cycle)

Cycle 50 GMT 24/ 7/2020 4: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.48 31 15.01 503 234 0.23 / 280.86 6 27
2 7 2006.36 40 14.66 3268 1916 2.15 / 282.77 27 69
3 13 1919.40 20 14.65 3158 925 3.08 / 283.70 5 75
4 13 1282.80 20 14.72 2259 665 3.74 / 284.36 5 89
5 13 653.76 20 14.88 1351 402 4.14 / 284.77 5 95
6 13 115.28 20 15.06 534 161 4.30 / 284.93 5 90
7 8 0.12 295 15.03 326 1445 5.75 / 286.37 5 145
Average= 5.62
(KJ/cycle)

Cycle 49 GMT 14/ 7/2020 6:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.36 31 15.02 489 228 0.23 / 275.07 6 30
2 7 2006.40 40 14.67 3256 1911 2.14 / 276.98 30 73
3 13 1911.88 20 14.65 3137 919 3.06 / 277.90 5 77
4 13 1168.88 20 14.75 2104 621 3.68 / 278.52 5 92
5 13 742.08 20 14.86 1479 440 4.12 / 278.96 5 96
6 13 179.76 20 15.04 645 194 4.31 / 279.16 5 93
7 8 0.12 300 15.03 325 1465 5.78 / 280.62 5 143
Average= 5.61
(KJ/cycle)

Cycle 48 GMT 4/ 7/2020 9:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.72 30 15.04 490 221 0.22 / 269.33 6 29
2 7 2012.16 40 14.67 3274 1921 2.14 / 271.25 29 71
3 13 1918.20 20 14.65 3157 925 3.07 / 272.18 5 76
4 13 1272.92 20 14.73 2240 660 3.73 / 272.84 5 91
5 13 620.20 20 14.90 1312 391 4.12 / 273.23 5 94
6 13 178.84 20 15.05 641 193 4.31 / 273.42 5 91
7 8 0.12 289 15.04 328 1426 5.74 / 274.85 5 147
Average= 5.61
(KJ/cycle)

Cycle 47 GMT 24/ 6/2020 12:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.88 30 15.04 499 225 0.23 / 263.54 6 25
2 7 2004.04 40 14.68 3252 1910 2.13 / 265.45 25 70
3 13 1807.48 20 14.68 2992 878 3.01 / 266.33 5 79
4 13 1612.32 20 14.65 2725 798 3.81 / 267.13 5 85
5 13 598.48 20 14.93 1272 380 4.19 / 267.51 5 96
6 13 162.68 20 15.07 616 186 4.38 / 267.69 5 91
7 8 0.00 289 15.05 326 1418 5.80 / 269.11 5 129
Average= 5.61
(KJ/cycle)

Cycle 46 GMT 14/ 6/2020 15:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.28 30 15.05 499 225 0.23 / 257.77 6 26
2 7 2007.28 40 14.68 3266 1918 2.14 / 259.69 26 72
3 13 1915.00 20 14.66 3145 922 3.07 / 260.61 5 76
4 13 1267.48 20 14.75 2248 663 3.73 / 261.28 5 91
5 13 631.68 20 14.91 1324 395 4.12 / 261.67 5 95
6 13 189.76 20 15.06 664 200 4.32 / 261.87 5 93
7 8 -0.04 295 15.05 325 1443 5.77 / 263.31 5 137
Average= 5.60
(KJ/cycle)

Cycle 45 GMT 4/ 6/2020 18:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.36 30 15.05 508 229 0.23 / 251.96 6 26
2 7 2012.84 40 14.68 3257 1913 2.14 / 253.87 26 72
3 13 1920.32 20 14.66 3148 923 3.06 / 254.79 5 77
4 13 1368.72 20 14.73 2372 699 3.76 / 255.49 5 89
5 13 718.72 20 14.90 1443 430 4.19 / 255.92 5 97
6 13 165.44 20 15.07 617 186 4.38 / 256.11 5 90
7 8 0.08 295 15.06 324 1439 5.82 / 257.55 5 135
Average= 5.60
(KJ/cycle)

Cycle 44 GMT 25/ 5/2020 21:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.00 30 15.06 503 227 0.23 / 246.22 6 19
2 7 2010.92 40 14.68 3268 1919 2.15 / 248.14 19 69
3 13 1916.68 20 14.66 3156 925 3.07 / 249.07 5 75
4 13 1364.68 20 14.73 2382 702 3.77 / 249.77 5 88
5 13 624.00 20 14.93 1309 391 4.16 / 250.16 5 96
6 13 84.60 20 15.11 481 145 4.31 / 250.31 5 89
7 8 0.08 287 15.07 329 1423 5.73 / 251.73 5 137
Average= 5.59
(KJ/cycle)

Cycle 43 GMT 16/ 5/2020 0: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.84 30 15.07 497 225 0.22 / 240.42 6 20
2 7 2004.68 40 14.68 3258 1913 2.14 / 242.34 20 69
3 13 1913.04 20 14.67 3137 920 3.06 / 243.26 5 75
4 13 1358.32 20 14.74 2372 699 3.76 / 243.96 5 87
5 13 615.20 20 14.94 1304 390 4.15 / 244.35 5 95
6 13 174.40 20 15.08 636 192 4.34 / 244.54 5 94
7 8 -0.04 295 15.07 328 1458 5.80 / 246.00 5 142
Average= 5.59
(KJ/cycle)

Cycle 42 GMT 6/ 5/2020 2:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.24 30 15.08 501 227 0.23 / 234.50 6 25
2 7 2012.68 40 14.69 3277 1926 2.15 / 236.43 25 71
3 13 1921.04 20 14.67 3156 926 3.08 / 237.36 5 76
4 13 1373.16 20 14.74 2384 703 3.78 / 238.06 5 89
5 13 820.48 20 14.88 1598 476 4.26 / 238.53 5 97
6 13 248.72 20 15.06 744 224 4.48 / 238.76 5 93
7 8 0.04 295 15.08 324 1441 5.92 / 240.20 5 158
Average= 5.59
(KJ/cycle)

Cycle 41 GMT 26/ 4/2020 5:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.40 30 15.08 492 223 0.22 / 228.59 6 20
2 7 2012.76 40 14.69 3272 1923 2.15 / 230.51 20 70
3 13 1919.88 20 14.67 3153 925 3.07 / 231.44 5 76
4 13 1491.72 20 14.72 2557 753 3.82 / 232.19 5 86
5 13 915.84 20 14.86 1737 516 4.34 / 232.70 5 96
6 13 115.84 20 15.12 531 161 4.50 / 232.87 5 85
7 8 0.04 289 15.09 324 1413 5.91 / 234.28 5 131
Average= 5.58
(KJ/cycle)

Cycle 40 GMT 16/ 4/2020 8:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.52 30 15.09 487 220 0.22 / 222.76 6 23
2 7 2006.88 40 14.69 3261 1916 2.14 / 224.68 23 69
3 13 1919.72 20 14.67 3157 926 3.06 / 225.60 5 75
4 13 1376.48 20 14.75 2391 705 3.77 / 226.31 5 88
5 13 726.60 20 14.92 1465 437 4.21 / 226.75 5 96
6 13 179.00 20 15.10 637 192 4.40 / 226.94 5 94
7 8 0.04 289 15.09 327 1426 5.82 / 228.37 5 133
Average= 5.57
(KJ/cycle)

Cycle 39 GMT 6/ 4/2020 11:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.24 30 15.09 482 218 0.22 / 217.05 6 21
2 7 2007.32 40 14.70 3260 1917 2.14 / 218.97 21 70
3 13 1913.12 20 14.68 3147 924 3.06 / 219.90 5 76
4 13 1274.80 20 14.78 2257 667 3.73 / 220.56 5 90
5 13 620.24 20 14.97 1310 392 4.12 / 220.96 5 97
6 13 86.44 20 15.14 492 149 4.27 / 221.10 5 88
7 8 0.00 285 15.10 334 1437 5.70 / 222.54 5 140
Average= 5.56
(KJ/cycle)

Cycle 38 GMT 27/ 3/2020 14: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.88 30 15.10 503 228 0.23 / 211.24 6 26
2 7 2011.88 40 14.70 3277 1927 2.15 / 213.16 26 73
3 13 1917.40 20 14.69 3150 925 3.08 / 214.09 5 77
4 13 1202.04 20 14.82 2140 634 3.71 / 214.72 5 92
5 13 766.16 20 14.92 1523 454 4.17 / 215.18 5 98
6 13 187.28 20 15.10 647 195 4.36 / 215.37 5 88
7 8 0.00 293 15.10 331 1464 5.83 / 216.84 5 130
Average= 5.56
(KJ/cycle)

Cycle 37 GMT 17/ 3/2020 16:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.68 30 15.10 499 226 0.23 / 205.48 6 26
2 7 2007.16 40 14.70 3260 1917 2.14 / 207.39 26 73
3 13 1918.08 20 14.69 3148 925 3.07 / 208.32 5 77
4 13 1181.56 20 14.83 2119 628 3.70 / 208.95 5 93
5 13 758.04 20 14.93 1505 449 4.15 / 209.39 5 99
6 13 171.88 20 15.12 626 189 4.34 / 209.58 5 95
7 8 0.08 289 15.11 326 1424 5.76 / 211.01 5 134
Average= 5.55
(KJ/cycle)

Cycle 36 GMT 7/ 3/2020 19:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.00 30 15.11 479 217 0.22 / 199.67 6 21
2 7 2010.16 40 14.71 3270 1924 2.14 / 201.60 21 70
3 13 1919.40 20 14.70 3157 928 3.07 / 202.52 5 76
4 13 1267.92 20 14.81 2238 663 3.73 / 203.19 5 91
5 13 725.84 20 14.95 1464 438 4.17 / 203.62 5 97
6 13 159.64 20 15.13 600 182 4.35 / 203.81 5 88
7 8 0.00 293 15.11 326 1443 5.79 / 205.25 5 144
Average= 5.55
(KJ/cycle)

Cycle 35 GMT 26/ 2/2020 22:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.00 30 15.10 493 223 0.22 / 193.93 6 28
2 7 2005.52 40 14.71 3254 1915 2.14 / 195.84 28 73
3 13 1910.96 20 14.70 3145 925 3.06 / 196.77 5 78
4 13 1467.04 20 14.76 2508 740 3.80 / 197.51 5 89
5 13 672.44 20 14.97 1372 411 4.21 / 197.92 5 99
6 13 61.32 20 15.17 447 136 4.35 / 198.06 5 86
7 8 0.12 283 15.12 327 1399 5.75 / 199.45 5 141
Average= 5.54
(KJ/cycle)

Cycle 34 GMT 17/ 2/2020 1: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.84 30 15.11 507 230 0.23 / 188.09 6 24
2 7 2006.72 40 14.71 3266 1922 2.15 / 190.01 24 70
3 13 1914.52 20 14.71 3154 928 3.08 / 190.94 5 76
4 13 1374.64 20 14.78 2400 709 3.79 / 191.64 5 88
5 13 798.24 20 14.93 1569 469 4.26 / 192.11 5 96
6 13 101.52 20 15.16 507 154 4.41 / 192.27 5 91
7 8 0.00 291 15.12 327 1439 5.85 / 193.71 5 129
Average= 5.53
(KJ/cycle)

Cycle 33 GMT 7/ 2/2020 4: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.64 30 15.12 500 227 0.23 / 182.17 6 29
2 7 2015.72 40 14.72 3279 1931 2.16 / 184.10 29 74
3 13 1930.20 20 14.71 3160 930 3.09 / 185.03 5 78
4 13 1477.64 20 14.76 2546 752 3.84 / 185.78 5 89
5 13 790.40 20 14.94 1554 464 4.30 / 186.25 5 98
6 13 120.08 20 15.16 543 165 4.47 / 186.41 5 91
7 8 -0.04 293 15.13 326 1445 5.91 / 187.86 5 134
Average= 5.53
(KJ/cycle)

Cycle 32 GMT 28/ 1/2020 7: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.52 30 15.13 489 222 0.22 / 176.45 6 30
2 7 2005.04 40 14.72 3253 1915 2.14 / 178.37 30 74
3 13 1906.88 20 14.71 3137 923 3.06 / 179.29 5 79
4 13 1279.52 20 14.82 2247 666 3.73 / 179.96 5 91
5 13 712.08 20 14.97 1442 432 4.16 / 180.39 5 98
6 13 73.20 20 15.18 463 141 4.30 / 180.53 5 85
7 8 0.08 285 15.14 328 1415 5.71 / 181.94 5 131
Average= 5.51
(KJ/cycle)

Cycle 31 GMT 18/ 1/2020 9:50: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.44 30 15.13 501 227 0.23 / 170.52 6 27
2 7 2008.92 40 14.73 3266 1924 2.15 / 172.44 27 69
3 13 1917.52 20 14.72 3142 925 3.08 / 173.36 5 76
4 13 1568.32 20 14.75 2663 786 3.86 / 174.15 5 85
5 13 765.16 20 14.96 1516 454 4.32 / 174.60 5 96
6 13 189.20 20 15.14 654 198 4.51 / 174.80 5 93
7 8 0.00 291 15.14 324 1427 5.94 / 176.23 5 130
Average= 5.51
(KJ/cycle)

Cycle 30 GMT 8/ 1/2020 12:50: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.84 30 15.13 500 227 0.23 / 164.79 6 31
2 7 2011.56 40 14.72 3276 1929 2.16 / 166.72 31 73
3 13 1920.52 20 14.72 3169 933 3.09 / 167.65 5 79
4 13 1278.32 20 14.83 2256 669 3.76 / 168.32 5 92
5 13 630.32 20 15.01 1316 395 4.15 / 168.71 5 98
6 13 96.92 20 15.18 504 153 4.31 / 168.87 5 88
7 8 0.00 289 15.14 325 1422 5.73 / 170.29 5 134
Average= 5.49
(KJ/cycle)

Cycle 29 GMT 29/12/2019 15:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.28 30 15.13 508 231 0.23 / 159.05 5 29
2 7 2003.44 40 14.74 3261 1923 2.15 / 160.97 29 70
3 13 1915.96 20 14.72 3157 929 3.08 / 161.90 5 77
4 13 1364.60 20 14.81 2374 703 3.79 / 162.60 5 89
5 13 597.12 20 15.02 1261 379 4.16 / 162.98 5 96
6 13 149.72 20 15.16 588 178 4.34 / 163.16 5 92
7 8 0.08 289 15.15 320 1401 5.74 / 164.56 5 130
Average= 5.49
(KJ/cycle)

Cycle 28 GMT 19/12/2019 18:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.00 30 15.13 499 226 0.23 / 153.18 6 32
2 7 2014.16 40 14.73 3269 1926 2.15 / 155.10 32 72
3 13 1923.88 20 14.73 3163 932 3.08 / 156.03 5 78
4 13 1394.28 20 14.81 2416 716 3.80 / 156.75 5 90
5 13 733.60 20 14.98 1472 441 4.24 / 157.19 5 99
6 13 169.16 20 15.16 623 189 4.43 / 157.38 5 92
7 8 0.08 291 15.15 326 1437 5.87 / 158.82 5 142
Average= 5.48
(KJ/cycle)

Cycle 27 GMT 9/12/2019 21:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.88 30 15.14 504 229 0.23 / 147.18 6 32
2 7 2005.72 41 14.74 3258 1969 2.20 / 149.15 32 74
3 13 1907.40 20 14.74 3137 925 3.12 / 150.07 5 80
4 13 1460.64 20 14.80 2518 745 3.87 / 150.82 5 90
5 13 994.12 20 14.90 1845 550 4.42 / 151.37 5 97
6 13 161.72 20 15.16 611 185 4.60 / 151.55 5 92
7 8 0.00 285 15.16 323 1396 6.00 / 152.95 5 135
Average= 5.46
(KJ/cycle)

Cycle 26 GMT 30/11/2019 0:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.76 30 15.14 502 228 0.23 / 141.20 6 33
2 7 2008.88 40 14.74 3266 1926 2.15 / 143.13 33 74
3 13 1921.88 20 14.74 3159 931 3.08 / 144.06 5 79
4 13 1600.88 20 14.76 2714 801 3.89 / 144.86 5 88
5 13 702.24 20 15.00 1434 430 4.32 / 145.29 5 99
6 13 256.88 20 15.13 753 228 4.54 / 145.52 5 92
7 8 0.00 289 15.16 327 1433 5.98 / 146.95 5 130
Average= 5.44
(KJ/cycle)

Cycle 25 GMT 20/11/2019 3: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.36 30 15.14 505 229 0.23 / 135.30 5 35
2 7 2006.40 40 14.75 3255 1920 2.15 / 137.22 35 74
3 13 1923.36 20 14.74 3161 932 3.08 / 138.15 5 81
4 13 1389.16 20 14.83 2405 713 3.80 / 138.86 5 93
5 13 927.68 20 14.92 1760 525 4.32 / 139.39 5 99
6 13 115.68 20 15.19 537 163 4.48 / 139.55 5 91
7 8 -0.04 289 15.16 325 1424 5.91 / 140.97 5 130
Average= 5.42
(KJ/cycle)

Cycle 24 GMT 10/11/2019 5:59: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.76 30 15.15 508 231 0.23 / 129.52 5 36
2 7 2008.60 40 14.74 3268 1927 2.16 / 131.44 36 74
3 13 1925.76 20 14.74 3158 931 3.09 / 132.37 5 80
4 13 1277.48 20 14.86 2260 672 3.76 / 133.05 5 95
5 13 627.56 20 15.03 1308 393 4.15 / 133.44 5 99
6 13 179.48 20 15.17 634 192 4.35 / 133.63 5 95
7 8 -0.04 291 15.16 325 1434 5.78 / 135.07 5 137
Average= 5.40
(KJ/cycle)

Cycle 23 GMT 31/10/2019 8:55: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.00 30 15.15 516 235 0.23 / 123.80 5 37
2 7 2009.36 40 14.75 3277 1933 2.17 / 125.74 37 75
3 13 1720.20 20 14.79 2875 850 3.02 / 126.59 5 85
4 13 1417.76 20 14.82 2456 728 3.75 / 127.31 5 92
5 13 568.08 20 15.05 1232 371 4.12 / 127.69 5 98
6 13 134.84 20 15.19 564 171 4.29 / 127.86 5 93
7 8 0.04 289 15.17 326 1429 5.72 / 129.29 5 132
Average= 5.39
(KJ/cycle)

Cycle 22 GMT 21/10/2019 11:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.16 30 15.16 494 225 0.22 / 117.91 5 37
2 7 2002.96 41 14.75 3270 1978 2.20 / 119.89 37 76
3 13 1909.04 20 14.76 3149 930 3.13 / 120.82 5 82
4 13 1265.96 20 14.87 2243 667 3.80 / 121.49 5 96
5 13 809.40 20 14.97 1588 475 4.27 / 121.96 5 100
6 13 124.64 20 15.19 554 168 4.44 / 122.13 5 93
7 8 0.08 289 15.17 328 1438 5.88 / 123.57 5 136
Average= 5.37
(KJ/cycle)

Cycle 21 GMT 11/10/2019 14:29: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.72 30 15.16 491 223 0.22 / 112.06 5 36
2 7 2010.24 40 14.76 3269 1930 2.15 / 113.99 36 75
3 13 1920.92 20 14.75 3180 938 3.09 / 114.93 5 81
4 13 1375.32 20 14.84 2389 709 3.80 / 115.64 5 93
5 13 717.80 20 15.01 1454 436 4.24 / 116.07 5 100
6 13 159.36 20 15.19 615 187 4.42 / 116.26 5 95
7 8 -0.04 287 15.18 328 1429 5.85 / 117.69 5 140
Average= 5.35
(KJ/cycle)

Cycle 20 GMT 1/10/2019 17:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.16 30 15.17 511 233 0.23 / 106.25 5 35
2 7 2012.84 40 14.77 3274 1934 2.17 / 108.19 35 75
3 13 1915.64 20 14.77 3149 930 3.10 / 109.12 5 82
4 13 1266.48 20 14.87 2246 668 3.77 / 109.79 5 95
5 13 732.04 20 15.01 1477 443 4.21 / 110.23 5 99
6 13 169.64 20 15.19 624 190 4.40 / 110.42 5 95
7 8 0.00 287 15.18 325 1416 5.81 / 111.84 5 133
Average= 5.33
(KJ/cycle)

Cycle 19 GMT 21/ 9/2019 20:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.44 30 15.17 512 233 0.23 / 100.41 5 37
2 7 2013.00 40 14.77 3289 1943 2.18 / 102.35 37 75
3 13 1921.00 20 14.77 3170 936 3.11 / 103.29 5 82
4 13 1384.84 20 14.85 2407 715 3.83 / 104.00 5 92
5 13 716.28 20 15.02 1455 437 4.26 / 104.44 5 101
6 13 156.08 20 15.19 607 184 4.45 / 104.62 5 95
7 8 0.04 278 15.18 331 1397 5.85 / 106.02 5 133
Average= 5.30
(KJ/cycle)

Cycle 18 GMT 11/ 9/2019 22:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.96 30 15.17 517 235 0.24 / 94.59 5 37
2 7 2007.60 41 14.77 3286 1990 2.23 / 96.58 37 76
3 13 1918.96 20 14.77 3165 935 3.16 / 97.52 5 81
4 13 1469.20 20 14.83 2536 752 3.91 / 98.27 5 93
5 13 582.84 20 15.07 1260 380 4.29 / 98.65 5 99
6 13 67.96 20 15.23 451 137 4.43 / 98.79 5 89
7 8 0.12 276 15.19 331 1388 5.82 / 100.18 5 134
Average= 5.27
(KJ/cycle)

Cycle 17 GMT 2/ 9/2019 1:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.60 30 15.17 499 227 0.23 / 88.75 5 37
2 7 2014.88 40 14.78 3304 1953 2.18 / 90.71 37 77
3 13 1926.72 20 14.78 3178 939 3.12 / 91.65 5 82
4 13 1293.16 20 14.88 2288 681 3.80 / 92.33 5 95
5 13 741.64 20 15.01 1493 448 4.25 / 92.77 5 102
6 13 163.44 20 15.19 625 190 4.44 / 92.96 5 97
7 8 0.12 270 15.18 340 1394 5.83 / 94.36 5 133
Average= 5.24
(KJ/cycle)

Cycle 16 GMT 23/ 8/2019 4:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.24 30 15.18 517 235 0.24 / 83.03 5 37
2 7 2004.20 40 14.78 3285 1942 2.18 / 84.97 37 77
3 13 1908.44 20 14.78 3151 931 3.11 / 85.90 5 83
4 13 1265.96 20 14.89 2254 671 3.78 / 86.57 5 96
5 13 608.60 20 15.06 1302 392 4.17 / 86.97 5 101
6 13 81.44 20 15.23 483 147 4.32 / 87.11 5 91
7 8 0.08 272 15.19 342 1413 5.73 / 88.53 5 130
Average= 5.21
(KJ/cycle)

Cycle 15 GMT 13/ 8/2019 7:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.20 29 15.18 509 224 0.22 / 77.16 6 36
2 7 2012.28 40 14.78 3304 1953 2.18 / 79.11 5 77
3 13 1914.56 20 14.79 3174 939 3.12 / 80.05 5 83
4 13 1374.08 20 14.86 2413 717 3.83 / 80.76 5 93
5 13 710.28 20 15.03 1464 440 4.27 / 81.20 5 101
6 13 135.36 20 15.21 585 178 4.45 / 81.38 5 96
7 8 0.04 270 15.19 344 1411 5.86 / 82.79 5 134
Average= 5.17
(KJ/cycle)

Cycle 14 GMT 3/ 8/2019 10:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.60 30 15.19 499 227 0.23 / 71.37 6 35
2 7 2015.00 40 14.78 3312 1958 2.19 / 73.33 35 77
3 13 1924.84 20 14.79 3184 942 3.13 / 74.27 5 83
4 13 1195.28 20 14.92 2159 644 3.77 / 74.91 5 96
5 13 748.96 20 15.02 1514 455 4.23 / 75.37 5 101
6 13 86.12 20 15.23 495 151 4.38 / 75.52 5 91
7 8 0.00 270 15.20 344 1412 5.79 / 76.93 5 135
Average= 5.13
(KJ/cycle)

Cycle 13 GMT 24/ 7/2019 13: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.96 29 15.19 517 228 0.23 / 65.63 6 34
2 7 2011.20 40 14.79 3302 1953 2.18 / 67.59 34 76
3 13 1928.16 20 14.78 3201 946 3.13 / 68.53 5 82
4 13 1365.20 20 14.88 2394 712 3.84 / 69.25 5 95
5 13 591.20 20 15.08 1285 388 4.23 / 69.63 5 101
6 8 0.40 289 15.21 343 1508 5.74 / 71.14 5 131
Average= 5.08
(KJ/cycle)

Cycle 12 GMT 14/ 7/2019 15:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.28 29 15.19 512 226 0.23 / 59.98 6 34
2 7 2009.92 40 14.79 3300 1952 2.18 / 61.93 34 76
3 13 1716.44 20 14.83 2904 861 3.04 / 62.80 5 88
4 13 1308.24 20 14.89 2313 689 3.73 / 63.48 5 97
5 13 545.72 20 15.10 1218 368 4.10 / 63.85 5 102
6 13 102.20 20 15.23 523 159 4.26 / 64.01 5 95
7 8 0.12 270 15.20 340 1395 5.65 / 65.41 5 131
Average= 5.03
(KJ/cycle)

Cycle 11 GMT 4/ 7/2019 18:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.96 29 15.20 493 217 0.22 / 54.15 6 32
2 7 2012.44 40 14.80 3298 1952 2.17 / 56.10 32 77
3 13 1922.16 20 14.80 3182 942 3.11 / 57.05 5 83
4 13 1265.92 20 14.91 2270 677 3.79 / 57.72 5 98
5 13 726.92 20 15.04 1487 447 4.24 / 58.17 5 102
6 13 157.04 20 15.21 617 188 4.42 / 58.36 5 97
7 8 -0.04 272 15.21 338 1398 5.82 / 59.76 5 133
Average= 4.98
(KJ/cycle)

Cycle 10 GMT 24/ 6/2019 21:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.00 29 15.19 512 226 0.23 / 48.44 6 32
2 7 2004.16 40 14.81 3294 1951 2.18 / 50.39 7 77
3 13 1908.32 20 14.81 3165 937 3.11 / 51.33 5 83
4 13 1269.16 20 14.91 2256 673 3.79 / 52.00 5 98
5 13 623.00 20 15.08 1324 399 4.19 / 52.40 5 102
6 13 89.76 20 15.25 491 150 4.34 / 52.55 5 93
7 8 -0.08 270 15.21 337 1384 5.72 / 53.93 5 133
Average= 4.90
(KJ/cycle)

Cycle 9 GMT 14/ 6/2019 23:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.56 29 15.21 507 224 0.22 / 42.52 6 31
2 7 2011.68 40 14.81 3307 1959 2.18 / 44.48 31 77
3 13 1915.28 20 14.81 3187 944 3.13 / 45.43 5 84
4 13 1468.80 20 14.86 2549 758 3.88 / 46.18 5 95
5 13 668.60 20 15.06 1403 423 4.31 / 46.61 5 104
6 13 201.68 20 15.20 690 210 4.52 / 46.82 5 100
7 8 0.00 272 15.21 338 1398 5.91 / 48.21 5 130
Average= 4.82
(KJ/cycle)

Cycle 8 GMT 5/ 6/2019 2:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.64 29 15.20 489 216 0.22 / 36.85 6 32
2 7 2011.44 40 14.82 3289 1950 2.17 / 38.80 32 75
3 13 1912.68 20 14.83 3169 940 3.11 / 39.74 5 83
4 13 1270.00 20 14.92 2263 675 3.78 / 40.41 5 97
5 13 529.92 20 15.12 1184 358 4.14 / 40.77 5 103
6 13 102.76 20 15.25 510 156 4.29 / 40.93 5 96
7 8 0.08 270 15.22 334 1373 5.67 / 42.30 5 131
Average= 4.70
(KJ/cycle)

Cycle 7 GMT 26/ 5/2019 5:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.52 29 15.20 489 216 0.22 / 31.12 6 33
2 7 2006.72 40 14.83 3290 1952 2.17 / 33.07 33 77
3 13 1918.16 20 14.82 3184 944 3.11 / 34.02 5 82
4 13 1163.28 20 14.95 2116 633 3.74 / 34.65 5 100
5 13 626.88 20 15.08 1332 402 4.15 / 35.05 5 104
6 13 189.36 20 15.21 660 201 4.35 / 35.25 5 101
7 8 0.12 267 15.21 340 1381 5.73 / 36.63 5 132
Average= 4.58
(KJ/cycle)

Cycle 6 GMT 16/ 5/2019 8:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.68 27 15.21 512 210 0.21 / 25.28 6 31
2 10 1029.36 3 15.17 1952 89 0.30 / 25.37 5 70
3 7 2012.56 40 14.83 3313 1965 2.26 / 27.34 70 76
4 13 1809.24 20 14.84 3037 901 3.17 / 28.24 5 85
5 13 1276.92 20 14.92 2279 680 3.85 / 28.92 5 97
6 13 608.44 20 15.09 1318 398 4.24 / 29.32 5 104
7 13 151.76 20 15.23 611 186 4.43 / 29.50 5 100
8 8 0.04 267 15.21 346 1405 5.83 / 30.91 5 129
Average= 4.42
(KJ/cycle)

Cycle 5 GMT 6/ 5/2019 11: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.76 31 15.22 497 234 0.23 / 19.63 6 33
2 3 903.28 -2 15.57 0 0 0.00 / 19.63 6 33
3 7 2011.80 40 14.83 3305 1961 2.20 / 21.59 33 77
4 13 1817.84 20 14.85 3044 904 3.10 / 22.49 5 85
5 13 1278.40 20 14.92 2279 680 3.78 / 23.17 5 98
6 13 617.80 20 15.09 1319 398 4.18 / 23.57 5 104
7 13 45.28 20 15.27 423 129 4.31 / 23.70 5 91
8 8 -0.04 265 15.22 340 1371 5.68 / 25.07 5 134
Average= 4.18
(KJ/cycle)

Cycle 4 GMT 26/ 4/2019 13:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.52 28 15.22 489 208 0.21 / 14.69 6 30
2 7 1511.48 40 15.02 2601 1563 1.77 / 16.25 30 80
3 13 1449.88 20 15.00 2520 756 2.53 / 17.01 5 85
4 13 1119.80 20 15.02 2056 618 3.14 / 17.63 5 95
5 13 356.44 20 15.20 931 283 3.43 / 17.91 5 101
6 13 28.92 20 15.29 394 120 3.55 / 18.03 5 89
7 8 0.00 265 15.24 338 1365 4.91 / 19.39 5 134
Average= 3.88
(KJ/cycle)

Cycle 3 GMT 25/ 4/2019 3:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.68 28 15.22 499 213 0.21 / 9.86 6 31
2 7 1506.96 40 15.02 2600 1562 1.77 / 11.42 22 81
3 13 1434.96 20 15.01 2496 749 2.52 / 12.17 5 84
4 13 1016.60 20 15.05 1908 574 3.10 / 12.75 5 96
5 13 367.16 20 15.20 946 288 3.39 / 13.04 5 100
6 13 35.08 20 15.29 406 124 3.51 / 13.16 5 89
7 8 0.04 255 15.24 340 1321 4.83 / 14.48 5 136
Average= 3.62
(KJ/cycle)

Cycle 2 GMT 23/ 4/2019 17: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.52 31 15.25 498 235 0.24 / 4.95 6 33
2 3 885.36 -2 15.58 0 0 0.00 / 4.95 6 33
3 7 1512.36 40 15.02 2595 1559 1.79 / 6.51 33 80
4 13 1445.68 20 15.00 2503 751 2.55 / 7.26 5 86
5 13 1237.36 20 14.99 2225 667 3.21 / 7.93 5 94
6 13 357.24 20 15.20 929 282 3.49 / 8.21 5 101
7 8 0.12 280 15.24 337 1438 4.93 / 9.65 5 134
Average= 3.22
(KJ/cycle)

Cycle 1 GMT 22/ 4/2019 6:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.48 31 15.45 465 223 0.22 / 1.92 6 21
2 3 862.36 -2 15.60 0 0 0.00 / 1.92 6 21
3 7 985.16 40 15.17 1816 1102 1.32 / 3.03 21 88
4 13 360.32 20 15.28 919 281 1.61 / 3.31 5 97
5 13 31.24 20 15.35 386 119 1.72 / 3.42 5 89
6 8 -0.08 259 15.30 326 1292 3.02 / 4.72 5 131
Average= 2.36
(KJ/cycle)

Cycle 0 GMT 21/ 4/2019 20: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 79.64 30 15.61 423 198 0.20 / 0.20 6 26
2 7 89.96 40 15.59 430 268 0.47 / 0.47 26 31
3 13 51.76 20 15.58 372 116 0.58 / 0.58 6 32
4 8 0.12 259 15.53 278 1118 1.70 / 1.70 6 137
Average= 1.70
(KJ/cycle)