SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.76 | 32 | 13.90 | 478 | 213 | 0.21 / 1274.08 | 5 | 64 |
2 | 3 | 915.88 | -1 | 13.90 | 478 | 0 | 0.00 / 1274.08 | 5 | 64 |
3 | 7 | 957.84 | 41 | 7.89 | 1569 | 508 | 0.72 / 1274.58 | 64 | 50 |
4 | 13 | 885.28 | 20 | 12.95 | 1565 | 405 | 1.13 / 1274.99 | 5 | 97 |
5 | 13 | 589.64 | 20 | 13.48 | 1144 | 308 | 1.43 / 1275.30 | 5 | 105 |
6 | 13 | 160.20 | 20 | 13.90 | 554 | 154 | 1.59 / 1275.45 | 5 | 95 |
7 | 8 | 0.04 | 400 | 13.68 | 332 | 1817 | 3.40 / 1277.27 | 5 | 80 |
Average= | 15.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.28 | 32 | 13.86 | 490 | 217 | 0.22 / 1267.61 | 5 | 70 |
2 | 3 | 912.36 | -1 | 13.86 | 490 | 0 | 0.00 / 1267.61 | 5 | 70 |
3 | 7 | 2005.96 | 40 | 4.71 | 1958 | 369 | 0.59 / 1267.98 | 70 | 5 |
4 | 13 | 2044.08 | 20 | 11.16 | 3048 | 680 | 1.27 / 1268.66 | 5 | 5 |
5 | 13 | 1997.20 | 20 | 11.48 | 3039 | 698 | 1.96 / 1269.35 | 5 | 28 |
6 | 13 | 1918.88 | 20 | 11.83 | 2931 | 693 | 2.66 / 1270.05 | 5 | 60 |
7 | 13 | 1822.88 | 20 | 12.11 | 2805 | 679 | 3.34 / 1270.73 | 5 | 72 |
8 | 13 | 1307.20 | 20 | 12.91 | 2135 | 551 | 3.89 / 1271.28 | 5 | 94 |
9 | 13 | 862.16 | 20 | 13.30 | 1547 | 412 | 4.30 / 1271.69 | 5 | 108 |
10 | 13 | 322.72 | 20 | 13.77 | 791 | 218 | 4.52 / 1271.91 | 5 | 112 |
11 | 13 | 19.40 | 20 | 14.02 | 383 | 107 | 4.63 / 1272.01 | 5 | 91 |
12 | 8 | 0.16 | 400 | 13.64 | 339 | 1850 | 6.47 / 1273.86 | 5 | 90 |
Average= | 15.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.64 | 29 | 13.92 | 458 | 185 | 0.18 / 1263.52 | 5 | 14 |
2 | 10 | 1033.48 | 5 | 13.48 | 1295 | 87 | 0.27 / 1263.61 | 5 | 9 |
3 | 10 | 1073.56 | 4 | 13.25 | 1486 | 79 | 0.35 / 1263.69 | 5 | 8 |
4 | 3 | 1124.64 | 3 | 12.39 | 1911 | 71 | 0.42 / 1263.76 | 5 | 23 |
5 | 7 | 1060.72 | 41 | 6.42 | 1588 | 418 | 0.84 / 1264.18 | 23 | 25 |
6 | 13 | 1001.20 | 20 | 12.68 | 1729 | 438 | 1.28 / 1264.61 | 5 | 92 |
7 | 13 | 913.16 | 20 | 12.99 | 1588 | 413 | 1.69 / 1265.03 | 5 | 97 |
8 | 13 | 587.92 | 20 | 13.46 | 1136 | 306 | 2.00 / 1265.33 | 5 | 106 |
9 | 13 | 35.44 | 20 | 13.99 | 397 | 111 | 2.11 / 1265.44 | 5 | 87 |
10 | 13 | 19.00 | 20 | 13.91 | 380 | 106 | 2.21 / 1265.55 | 5 | 89 |
11 | 8 | 0.08 | 400 | 13.61 | 338 | 1840 | 4.05 / 1267.39 | 5 | 96 |
Average= | 15.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.20 | 31 | 13.88 | 472 | 203 | 0.20 / 1260.11 | 5 | 63 |
2 | 3 | 942.28 | -1 | 13.88 | 472 | 0 | 0.00 / 1260.11 | 5 | 63 |
3 | 7 | 975.04 | 40 | 6.89 | 1526 | 421 | 0.62 / 1260.53 | 63 | 39 |
4 | 13 | 912.36 | 20 | 12.75 | 1611 | 411 | 1.03 / 1260.94 | 5 | 93 |
5 | 13 | 820.04 | 20 | 13.03 | 1480 | 386 | 1.42 / 1261.32 | 5 | 101 |
6 | 13 | 276.72 | 20 | 13.77 | 696 | 192 | 1.61 / 1261.51 | 5 | 99 |
7 | 8 | 0.28 | 400 | 13.67 | 333 | 1821 | 3.43 / 1263.34 | 5 | 78 |
Average= | 15.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.60 | 38 | 13.83 | 479 | 252 | 0.25 / 1256.70 | 5 | 68 |
2 | 3 | 770.28 | -4 | 13.83 | 479 | 0 | 0.00 / 1256.70 | 5 | 68 |
3 | 7 | 880.68 | 41 | 8.17 | 1443 | 483 | 0.74 / 1257.18 | 68 | 56 |
4 | 13 | 799.72 | 20 | 13.04 | 1448 | 378 | 1.11 / 1257.56 | 5 | 99 |
5 | 13 | 507.44 | 20 | 13.55 | 1031 | 279 | 1.39 / 1257.84 | 5 | 108 |
6 | 13 | 95.20 | 20 | 13.93 | 472 | 131 | 1.52 / 1257.97 | 5 | 91 |
7 | 13 | 48.76 | 20 | 13.93 | 416 | 116 | 1.64 / 1258.09 | 5 | 92 |
8 | 8 | -0.28 | 400 | 13.64 | 333 | 1817 | 3.46 / 1259.90 | 5 | 91 |
Average= | 15.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.16 | 37 | 13.82 | 493 | 252 | 0.25 / 1250.23 | 5 | 73 |
2 | 3 | 826.80 | -3 | 13.82 | 493 | 0 | 0.00 / 1250.23 | 5 | 73 |
3 | 7 | 2003.68 | 40 | 4.69 | 1866 | 350 | 0.60 / 1250.58 | 73 | 5 |
4 | 13 | 2042.60 | 20 | 11.10 | 3047 | 676 | 1.28 / 1251.25 | 5 | 5 |
5 | 13 | 1998.08 | 20 | 11.59 | 3016 | 699 | 1.98 / 1251.95 | 5 | 31 |
6 | 13 | 1922.12 | 20 | 11.83 | 2941 | 696 | 2.67 / 1252.65 | 5 | 60 |
7 | 13 | 1823.76 | 20 | 12.18 | 2796 | 681 | 3.35 / 1253.33 | 5 | 72 |
8 | 13 | 1293.56 | 20 | 12.89 | 2118 | 546 | 3.90 / 1253.88 | 5 | 93 |
9 | 13 | 865.00 | 20 | 13.28 | 1544 | 410 | 4.31 / 1254.29 | 5 | 107 |
10 | 13 | 307.60 | 20 | 13.76 | 772 | 212 | 4.52 / 1254.50 | 5 | 113 |
11 | 13 | 23.24 | 20 | 14.00 | 385 | 108 | 4.63 / 1254.61 | 5 | 94 |
12 | 8 | 0.36 | 400 | 13.61 | 338 | 1840 | 6.47 / 1256.45 | 5 | 108 |
Average= | 16.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.44 | 34 | 13.83 | 492 | 231 | 0.23 / 1246.72 | 5 | 70 |
2 | 3 | 862.04 | -2 | 13.83 | 492 | 0 | 0.00 / 1246.72 | 5 | 70 |
3 | 7 | 951.96 | 40 | 6.26 | 1456 | 365 | 0.60 / 1247.08 | 70 | 30 |
4 | 13 | 892.08 | 20 | 12.67 | 1569 | 398 | 0.99 / 1247.48 | 5 | 94 |
5 | 13 | 806.96 | 20 | 12.96 | 1466 | 380 | 1.37 / 1247.86 | 5 | 103 |
6 | 13 | 493.32 | 20 | 13.48 | 1030 | 278 | 1.65 / 1248.14 | 5 | 112 |
7 | 8 | 0.12 | 400 | 13.63 | 337 | 1837 | 3.49 / 1249.98 | 5 | 118 |
Average= | 16.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.68 | 38 | 13.79 | 488 | 256 | 0.26 / 1243.48 | 5 | 78 |
2 | 3 | 815.36 | -3 | 13.79 | 488 | 0 | 0.00 / 1243.48 | 5 | 78 |
3 | 7 | 902.24 | 40 | 6.92 | 1449 | 401 | 0.66 / 1243.88 | 78 | 43 |
4 | 13 | 830.20 | 20 | 12.89 | 1493 | 385 | 1.04 / 1244.26 | 5 | 97 |
5 | 13 | 631.44 | 20 | 13.33 | 1212 | 323 | 1.36 / 1244.59 | 5 | 107 |
6 | 13 | 208.60 | 20 | 13.80 | 622 | 172 | 1.54 / 1244.76 | 5 | 102 |
7 | 13 | 20.68 | 20 | 13.96 | 381 | 106 | 1.64 / 1244.86 | 5 | 92 |
8 | 8 | 0.08 | 357 | 13.58 | 335 | 1624 | 3.27 / 1246.49 | 5 | 132 |
Average= | 16.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.60 | 28 | 13.87 | 458 | 178 | 0.18 / 1239.67 | 5 | 19 |
2 | 10 | 1024.12 | 5 | 13.10 | 1773 | 116 | 0.29 / 1239.78 | 5 | 48 |
3 | 10 | 1100.08 | 3 | 13.21 | 1895 | 75 | 0.37 / 1239.86 | 5 | 22 |
4 | 3 | 1081.04 | 2 | 12.42 | 1860 | 46 | 0.42 / 1239.90 | 5 | 9 |
5 | 7 | 1026.72 | 40 | 6.77 | 1566 | 424 | 0.84 / 1240.33 | 9 | 35 |
6 | 13 | 951.08 | 20 | 12.91 | 1646 | 425 | 1.26 / 1240.75 | 5 | 95 |
7 | 13 | 854.60 | 20 | 13.17 | 1497 | 394 | 1.66 / 1241.15 | 5 | 101 |
8 | 13 | 426.88 | 20 | 13.67 | 904 | 247 | 1.91 / 1241.40 | 5 | 106 |
9 | 8 | 0.16 | 400 | 13.58 | 336 | 1825 | 3.73 / 1243.22 | 5 | 76 |
Average= | 16.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.24 | 41 | 13.79 | 463 | 262 | 0.26 / 1233.46 | 5 | 53 |
2 | 3 | 806.92 | -3 | 13.79 | 463 | 0 | 0.00 / 1233.46 | 5 | 53 |
3 | 7 | 2010.04 | 41 | 4.65 | 1696 | 323 | 0.59 / 1233.78 | 53 | 5 |
4 | 13 | 2049.88 | 20 | 10.74 | 3028 | 650 | 1.24 / 1234.43 | 5 | 5 |
5 | 13 | 2012.44 | 20 | 11.56 | 3000 | 694 | 1.93 / 1235.12 | 5 | 31 |
6 | 13 | 1941.00 | 20 | 11.86 | 2941 | 698 | 2.63 / 1235.82 | 5 | 60 |
7 | 13 | 1843.28 | 20 | 12.17 | 2833 | 690 | 3.32 / 1236.51 | 5 | 72 |
8 | 13 | 1213.52 | 20 | 12.99 | 1990 | 517 | 3.83 / 1237.03 | 5 | 95 |
9 | 13 | 790.00 | 20 | 13.47 | 1319 | 355 | 4.19 / 1237.38 | 5 | 75 |
10 | 13 | 376.68 | 20 | 13.78 | 683 | 188 | 4.38 / 1237.57 | 5 | 62 |
11 | 13 | 81.16 | 20 | 13.96 | 423 | 118 | 4.49 / 1237.69 | 5 | 62 |
12 | 13 | 18.88 | 20 | 13.98 | 366 | 102 | 4.60 / 1237.79 | 5 | 57 |
13 | 8 | 0.08 | 379 | 13.65 | 328 | 1697 | 6.29 / 1239.49 | 5 | 85 |
Average= | 16.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.60 | 28 | 13.83 | 464 | 180 | 0.18 / 1229.42 | 5 | 19 |
2 | 10 | 1016.28 | 5 | 13.24 | 1367 | 90 | 0.27 / 1229.51 | 5 | 15 |
3 | 10 | 1045.28 | 3 | 13.52 | 1340 | 54 | 0.32 / 1229.56 | 5 | 5 |
4 | 3 | 1109.16 | 3 | 12.83 | 1406 | 54 | 0.38 / 1229.62 | 5 | 5 |
5 | 7 | 1059.48 | 40 | 7.14 | 1285 | 367 | 0.75 / 1229.98 | 5 | 15 |
6 | 13 | 991.56 | 20 | 12.97 | 1298 | 337 | 1.08 / 1230.32 | 5 | 52 |
7 | 13 | 911.08 | 20 | 12.87 | 1589 | 409 | 1.49 / 1230.73 | 5 | 96 |
8 | 13 | 812.84 | 20 | 13.08 | 1469 | 384 | 1.88 / 1231.11 | 5 | 103 |
9 | 13 | 252.16 | 20 | 13.75 | 678 | 186 | 2.06 / 1231.30 | 5 | 103 |
10 | 13 | 11.20 | 20 | 13.97 | 360 | 101 | 2.16 / 1231.40 | 5 | 90 |
11 | 8 | 0.04 | 400 | 13.59 | 330 | 1794 | 3.96 / 1233.20 | 5 | 43 |
Average= | 16.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.72 | 28 | 13.87 | 497 | 193 | 0.19 / 1225.80 | 5 | 69 |
2 | 7 | 998.56 | 40 | 5.95 | 1470 | 350 | 0.54 / 1226.15 | 69 | 18 |
3 | 13 | 963.16 | 20 | 12.59 | 1665 | 419 | 0.96 / 1226.57 | 5 | 88 |
4 | 13 | 880.00 | 20 | 12.90 | 1555 | 401 | 1.36 / 1226.97 | 5 | 96 |
5 | 13 | 677.44 | 20 | 13.28 | 1277 | 339 | 1.70 / 1227.31 | 5 | 104 |
6 | 13 | 26.32 | 20 | 13.96 | 381 | 106 | 1.81 / 1227.42 | 5 | 91 |
7 | 8 | 0.00 | 400 | 13.61 | 334 | 1818 | 3.63 / 1229.24 | 5 | 117 |
Average= | 17.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.44 | 30 | 13.88 | 475 | 198 | 0.20 / 1222.22 | 5 | 63 |
2 | 3 | 954.88 | -1 | 13.88 | 475 | 0 | 0.00 / 1222.22 | 5 | 63 |
3 | 7 | 998.72 | 40 | 7.08 | 1532 | 434 | 0.63 / 1222.65 | 63 | 40 |
4 | 13 | 931.88 | 20 | 12.94 | 1627 | 421 | 1.05 / 1223.07 | 5 | 93 |
5 | 13 | 741.48 | 20 | 13.29 | 1371 | 364 | 1.42 / 1223.44 | 5 | 104 |
6 | 13 | 224.84 | 20 | 13.81 | 623 | 172 | 1.59 / 1223.61 | 5 | 93 |
7 | 13 | 24.00 | 20 | 13.97 | 376 | 105 | 1.69 / 1223.71 | 5 | 89 |
8 | 13 | 12.56 | 20 | 13.90 | 361 | 100 | 1.79 / 1223.81 | 5 | 92 |
9 | 8 | 0.12 | 400 | 13.61 | 330 | 1797 | 3.59 / 1225.61 | 5 | 121 |
Average= | 17.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.72 | 41 | 13.90 | 439 | 250 | 0.25 / 1216.01 | 5 | 18 |
2 | 7 | 2003.36 | 40 | 4.61 | 1523 | 281 | 0.53 / 1216.30 | 5 | 6 |
3 | 13 | 2048.64 | 20 | 9.68 | 3012 | 583 | 1.11 / 1216.88 | 5 | 5 |
4 | 13 | 2013.68 | 20 | 11.36 | 3046 | 692 | 1.81 / 1217.57 | 5 | 22 |
5 | 13 | 1937.88 | 20 | 11.82 | 2947 | 697 | 2.50 / 1218.27 | 5 | 57 |
6 | 13 | 1847.00 | 20 | 12.16 | 2833 | 689 | 3.19 / 1218.96 | 5 | 70 |
7 | 13 | 1323.76 | 20 | 12.85 | 2155 | 554 | 3.75 / 1219.51 | 5 | 93 |
8 | 13 | 919.40 | 20 | 13.22 | 1601 | 423 | 4.17 / 1219.93 | 5 | 102 |
9 | 13 | 489.12 | 20 | 13.59 | 999 | 272 | 4.44 / 1220.20 | 5 | 108 |
10 | 8 | 0.40 | 400 | 13.67 | 332 | 1815 | 6.26 / 1222.02 | 5 | 66 |
Average= | 17.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.40 | 33 | 13.89 | 486 | 223 | 0.22 / 1212.62 | 5 | 59 |
2 | 3 | 815.00 | -3 | 13.89 | 486 | 0 | 0.00 / 1212.62 | 5 | 59 |
3 | 7 | 903.80 | 41 | 5.99 | 1355 | 333 | 0.56 / 1212.95 | 59 | 21 |
4 | 13 | 844.68 | 20 | 12.82 | 1458 | 374 | 0.93 / 1213.33 | 5 | 86 |
5 | 13 | 759.56 | 20 | 13.07 | 1362 | 356 | 1.29 / 1213.68 | 5 | 90 |
6 | 13 | 441.80 | 20 | 13.59 | 889 | 242 | 1.53 / 1213.92 | 5 | 88 |
7 | 13 | 9.28 | 20 | 14.03 | 338 | 95 | 1.62 / 1214.02 | 5 | 95 |
8 | 8 | -0.28 | 400 | 13.81 | 316 | 1746 | 3.37 / 1215.76 | 5 | 79 |
Average= | 17.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.48 | 49 | 13.87 | 458 | 311 | 0.31 / 1209.61 | 5 | 59 |
2 | 3 | 346.12 | -10 | 13.87 | 458 | 0 | 0.00 / 1209.61 | 5 | 59 |
3 | 7 | 777.24 | 41 | 6.21 | 1217 | 310 | 0.62 / 1209.92 | 59 | 25 |
4 | 13 | 724.32 | 20 | 12.88 | 1264 | 326 | 0.95 / 1210.24 | 5 | 79 |
5 | 13 | 634.60 | 20 | 13.24 | 1131 | 299 | 1.25 / 1210.54 | 5 | 78 |
6 | 13 | 62.40 | 20 | 13.99 | 404 | 113 | 1.36 / 1210.65 | 5 | 74 |
7 | 8 | 0.20 | 400 | 13.88 | 314 | 1743 | 3.10 / 1212.40 | 5 | 102 |
Average= | 17.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.12 | 29 | 14.00 | 441 | 179 | 0.18 / 1205.86 | 5 | 30 |
2 | 3 | 1031.32 | 1 | 11.82 | 1743 | 21 | 0.20 / 1205.88 | 5 | 5 |
3 | 7 | 1025.20 | 40 | 6.32 | 1498 | 379 | 0.58 / 1206.26 | 5 | 24 |
4 | 13 | 968.76 | 20 | 13.16 | 1416 | 373 | 0.95 / 1206.63 | 5 | 39 |
5 | 13 | 886.92 | 20 | 13.27 | 1200 | 318 | 1.27 / 1206.95 | 5 | 51 |
6 | 13 | 790.44 | 20 | 13.56 | 1041 | 282 | 1.55 / 1207.23 | 5 | 55 |
7 | 13 | 256.32 | 20 | 13.86 | 575 | 159 | 1.71 / 1207.39 | 5 | 59 |
8 | 13 | 84.64 | 20 | 14.01 | 402 | 113 | 1.82 / 1207.51 | 5 | 60 |
9 | 13 | 3.56 | 20 | 14.06 | 319 | 90 | 1.91 / 1207.60 | 5 | 49 |
10 | 8 | 0.12 | 400 | 13.87 | 306 | 1698 | 3.61 / 1209.29 | 5 | 82 |
Average= | 18.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.20 | 34 | 13.96 | 430 | 204 | 0.20 / 1199.37 | 5 | 8 |
2 | 10 | 1053.28 | 4 | 12.98 | 1265 | 66 | 0.27 / 1199.44 | 5 | 7 |
3 | 3 | 1134.20 | 3 | 12.11 | 1534 | 56 | 0.33 / 1199.50 | 5 | 7 |
4 | 7 | 2009.72 | 41 | 4.61 | 1528 | 289 | 0.61 / 1199.78 | 7 | 6 |
5 | 13 | 2059.20 | 20 | 10.52 | 2886 | 607 | 1.22 / 1200.39 | 5 | 5 |
6 | 13 | 2025.92 | 20 | 11.50 | 3060 | 704 | 1.93 / 1201.10 | 5 | 25 |
7 | 13 | 1953.36 | 20 | 11.91 | 2964 | 706 | 2.63 / 1201.80 | 5 | 56 |
8 | 13 | 1860.80 | 20 | 12.20 | 2834 | 691 | 3.32 / 1202.49 | 5 | 68 |
9 | 13 | 1453.76 | 20 | 12.76 | 2319 | 592 | 3.91 / 1203.09 | 5 | 86 |
10 | 13 | 1122.08 | 20 | 13.08 | 1850 | 484 | 4.40 / 1203.57 | 5 | 95 |
11 | 13 | 453.92 | 20 | 13.69 | 906 | 248 | 4.65 / 1203.82 | 5 | 91 |
12 | 13 | 51.60 | 20 | 14.02 | 397 | 111 | 4.76 / 1203.93 | 5 | 91 |
13 | 8 | -0.16 | 399 | 13.87 | 317 | 1754 | 6.51 / 1205.68 | 5 | 93 |
Average= | 18.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.76 | 59 | 13.84 | 434 | 354 | 0.35 / 1196.31 | 5 | 29 |
2 | 3 | 550.36 | -7 | 13.84 | 434 | 0 | 0.00 / 1196.31 | 5 | 29 |
3 | 7 | 840.32 | 41 | 6.00 | 1268 | 312 | 0.67 / 1196.62 | 29 | 22 |
4 | 13 | 781.92 | 20 | 12.86 | 1373 | 353 | 1.02 / 1196.97 | 5 | 78 |
5 | 13 | 689.52 | 20 | 13.23 | 1218 | 322 | 1.34 / 1197.30 | 5 | 80 |
6 | 13 | 172.40 | 20 | 13.89 | 542 | 151 | 1.49 / 1197.45 | 5 | 79 |
7 | 8 | 0.12 | 400 | 13.90 | 310 | 1724 | 3.22 / 1199.17 | 5 | 48 |
Average= | 18.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.20 | 81 | 13.89 | 409 | 460 | 0.46 / 1193.21 | 5 | 30 |
2 | 3 | 99.04 | -14 | 13.89 | 409 | 0 | 0.00 / 1193.21 | 5 | 30 |
3 | 7 | 741.40 | 40 | 7.18 | 969 | 278 | 0.74 / 1193.49 | 30 | 12 |
4 | 13 | 675.84 | 20 | 13.13 | 951 | 250 | 0.99 / 1193.74 | 5 | 44 |
5 | 13 | 587.48 | 20 | 13.57 | 829 | 225 | 1.21 / 1193.96 | 5 | 45 |
6 | 13 | 391.28 | 20 | 13.81 | 659 | 182 | 1.40 / 1194.14 | 5 | 44 |
7 | 13 | 38.76 | 20 | 14.03 | 356 | 100 | 1.50 / 1194.24 | 5 | 47 |
8 | 8 | 0.32 | 400 | 13.90 | 308 | 1712 | 3.21 / 1195.95 | 5 | 70 |
Average= | 18.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.72 | 29 | 13.98 | 474 | 192 | 0.19 / 1189.48 | 5 | 47 |
2 | 7 | 1007.24 | 41 | 6.56 | 1503 | 404 | 0.60 / 1189.88 | 5 | 28 |
3 | 13 | 945.44 | 20 | 13.02 | 1621 | 422 | 1.02 / 1190.31 | 5 | 85 |
4 | 13 | 852.84 | 20 | 13.23 | 1470 | 389 | 1.41 / 1190.69 | 5 | 89 |
5 | 13 | 433.96 | 20 | 13.69 | 882 | 241 | 1.65 / 1190.94 | 5 | 89 |
6 | 13 | 4.04 | 20 | 14.08 | 324 | 91 | 1.74 / 1191.03 | 5 | 68 |
7 | 8 | -0.20 | 400 | 13.87 | 310 | 1720 | 3.46 / 1192.75 | 5 | 87 |
Average= | 18.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.44 | 34 | 13.94 | 441 | 209 | 0.21 / 1183.15 | 5 | 37 |
2 | 7 | 2002.04 | 41 | 4.69 | 1808 | 348 | 0.56 / 1183.49 | 5 | 5 |
3 | 13 | 2045.16 | 20 | 11.80 | 3045 | 719 | 1.28 / 1184.21 | 5 | 9 |
4 | 13 | 2004.56 | 20 | 12.13 | 3017 | 732 | 2.01 / 1184.94 | 5 | 49 |
5 | 13 | 1933.12 | 20 | 12.34 | 2940 | 726 | 2.73 / 1185.67 | 5 | 67 |
6 | 13 | 1638.92 | 20 | 12.80 | 2387 | 611 | 3.34 / 1186.28 | 5 | 61 |
7 | 13 | 1441.96 | 20 | 13.03 | 1997 | 520 | 3.86 / 1186.80 | 5 | 76 |
8 | 13 | 913.28 | 20 | 13.44 | 1320 | 355 | 4.22 / 1187.16 | 5 | 93 |
9 | 13 | 591.80 | 20 | 13.62 | 1031 | 281 | 4.50 / 1187.44 | 5 | 67 |
10 | 13 | 67.04 | 20 | 14.04 | 402 | 113 | 4.61 / 1187.55 | 5 | 62 |
11 | 8 | 0.16 | 399 | 13.91 | 313 | 1737 | 6.35 / 1189.29 | 5 | 62 |
Average= | 19.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.60 | 53 | 13.93 | 411 | 303 | 0.30 / 1178.07 | 5 | 5 |
2 | 10 | 1114.80 | 9 | 12.94 | 1501 | 175 | 0.48 / 1178.25 | 5 | 5 |
3 | 10 | 1195.80 | 7 | 13.84 | 1323 | 128 | 0.61 / 1178.38 | 5 | 5 |
4 | 10 | 1256.52 | 6 | 13.82 | 1403 | 116 | 0.72 / 1178.49 | 5 | 5 |
5 | 3 | 1257.24 | 6 | 13.05 | 1576 | 123 | 0.85 / 1178.62 | 5 | 8 |
6 | 7 | 1477.00 | 41 | 12.93 | 1397 | 741 | 1.59 / 1179.36 | 8 | 21 |
7 | 13 | 1400.08 | 20 | 13.18 | 1520 | 401 | 1.99 / 1179.76 | 5 | 21 |
8 | 13 | 1308.00 | 20 | 13.28 | 1291 | 343 | 2.33 / 1180.10 | 5 | 10 |
9 | 13 | 1127.44 | 20 | 13.51 | 1105 | 299 | 2.63 / 1180.40 | 5 | 12 |
10 | 13 | 926.84 | 20 | 13.51 | 1024 | 277 | 2.91 / 1180.68 | 5 | 13 |
11 | 13 | 638.56 | 20 | 13.80 | 763 | 211 | 3.12 / 1180.89 | 5 | 14 |
12 | 13 | 430.92 | 20 | 13.86 | 586 | 162 | 3.28 / 1181.05 | 5 | 5 |
13 | 13 | 124.28 | 20 | 14.02 | 380 | 107 | 3.39 / 1181.16 | 5 | 13 |
14 | 13 | 13.96 | 20 | 14.08 | 325 | 92 | 3.48 / 1181.25 | 5 | 15 |
15 | 8 | 0.12 | 399 | 13.89 | 305 | 1690 | 5.17 / 1182.94 | 5 | 48 |
Average= | 19.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.52 | 52 | 13.95 | 387 | 281 | 0.28 / 1174.14 | 5 | 5 |
2 | 3 | 1066.00 | 2 | 11.85 | 1767 | 42 | 0.32 / 1174.18 | 5 | 5 |
3 | 7 | 1039.36 | 40 | 4.59 | 1454 | 267 | 0.59 / 1174.45 | 5 | 6 |
4 | 13 | 1032.16 | 20 | 13.41 | 976 | 262 | 0.85 / 1174.71 | 5 | 5 |
5 | 13 | 992.88 | 20 | 13.44 | 944 | 254 | 1.11 / 1174.97 | 5 | 18 |
6 | 13 | 926.88 | 20 | 13.60 | 873 | 237 | 1.34 / 1175.20 | 5 | 10 |
7 | 13 | 847.92 | 20 | 13.52 | 823 | 223 | 1.57 / 1175.43 | 5 | 7 |
8 | 13 | 766.56 | 20 | 13.56 | 707 | 192 | 1.76 / 1175.62 | 5 | 8 |
9 | 13 | 677.80 | 20 | 13.64 | 763 | 208 | 1.96 / 1175.83 | 5 | 25 |
10 | 13 | 578.88 | 20 | 13.75 | 673 | 185 | 2.15 / 1176.01 | 5 | 8 |
11 | 13 | 88.20 | 20 | 14.01 | 377 | 106 | 2.26 / 1176.12 | 5 | 33 |
12 | 8 | 0.00 | 400 | 13.92 | 297 | 1654 | 3.91 / 1177.77 | 5 | 12 |
Average= | 19.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.92 | 29 | 13.97 | 469 | 190 | 0.19 / 1170.63 | 5 | 42 |
2 | 7 | 990.64 | 40 | 6.18 | 1454 | 359 | 0.55 / 1170.99 | 42 | 19 |
3 | 13 | 935.56 | 20 | 12.87 | 1624 | 418 | 0.97 / 1171.40 | 5 | 83 |
4 | 13 | 856.00 | 20 | 13.10 | 1508 | 395 | 1.36 / 1171.80 | 5 | 88 |
5 | 13 | 436.12 | 20 | 13.65 | 895 | 244 | 1.61 / 1172.04 | 5 | 86 |
6 | 13 | 5.36 | 20 | 14.07 | 323 | 91 | 1.70 / 1172.14 | 5 | 79 |
7 | 8 | 0.12 | 400 | 13.87 | 311 | 1725 | 3.42 / 1173.86 | 5 | 49 |
Average= | 19.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.76 | 49 | 13.93 | 429 | 293 | 0.29 / 1164.38 | 5 | 37 |
2 | 3 | 345.52 | -10 | 13.93 | 429 | 0 | 0.00 / 1164.38 | 5 | 37 |
3 | 7 | 2002.76 | 40 | 4.56 | 1317 | 240 | 0.53 / 1164.62 | 37 | 6 |
4 | 13 | 2046.48 | 20 | 7.85 | 2944 | 462 | 1.00 / 1165.08 | 5 | 5 |
5 | 13 | 2044.44 | 20 | 11.48 | 3043 | 699 | 1.69 / 1165.78 | 5 | 15 |
6 | 13 | 1979.60 | 20 | 11.94 | 2982 | 712 | 2.41 / 1166.49 | 5 | 51 |
7 | 13 | 1890.56 | 20 | 12.23 | 2865 | 701 | 3.11 / 1167.19 | 5 | 66 |
8 | 13 | 1688.56 | 20 | 12.67 | 2491 | 631 | 3.74 / 1167.82 | 5 | 65 |
9 | 13 | 1158.76 | 20 | 13.25 | 1494 | 396 | 4.13 / 1168.22 | 5 | 53 |
10 | 13 | 753.72 | 20 | 13.55 | 1045 | 283 | 4.42 / 1168.50 | 5 | 56 |
11 | 13 | 435.60 | 20 | 13.72 | 752 | 206 | 4.62 / 1168.71 | 5 | 53 |
12 | 13 | 48.28 | 20 | 14.05 | 368 | 103 | 4.73 / 1168.81 | 5 | 46 |
13 | 8 | 0.00 | 380 | 13.94 | 307 | 1626 | 6.35 / 1170.44 | 5 | 112 |
Average= | 20.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.52 | 74 | 13.86 | 444 | 455 | 0.46 / 1160.95 | 5 | 50 |
2 | 3 | 98.80 | -14 | 13.86 | 444 | 0 | 0.00 / 1160.95 | 5 | 50 |
3 | 7 | 919.44 | 40 | 4.71 | 1360 | 256 | 0.71 / 1161.21 | 50 | 5 |
4 | 13 | 919.40 | 20 | 12.67 | 1510 | 383 | 1.09 / 1161.59 | 5 | 69 |
5 | 13 | 836.72 | 20 | 13.11 | 1377 | 361 | 1.46 / 1161.95 | 5 | 73 |
6 | 13 | 746.32 | 20 | 13.29 | 1252 | 333 | 1.79 / 1162.28 | 5 | 78 |
7 | 13 | 50.68 | 20 | 14.03 | 371 | 104 | 1.89 / 1162.39 | 5 | 50 |
8 | 8 | 0.12 | 400 | 13.92 | 305 | 1698 | 3.59 / 1164.08 | 5 | 62 |
Average= | 20.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.48 | 56 | 14.01 | 343 | 269 | 0.27 / 1156.51 | 5 | 5 |
2 | 10 | 1037.76 | 5 | 13.36 | 898 | 60 | 0.33 / 1156.57 | 5 | 5 |
3 | 10 | 1095.12 | 5 | 12.98 | 1508 | 98 | 0.43 / 1156.67 | 5 | 5 |
4 | 10 | 1123.28 | 3 | 13.14 | 1882 | 74 | 0.50 / 1156.75 | 5 | 5 |
5 | 3 | 1204.12 | 5 | 14.06 | 458 | 32 | 0.53 / 1156.78 | 5 | 23 |
6 | 7 | 1110.84 | 40 | 4.58 | 1400 | 256 | 0.79 / 1157.03 | 23 | 6 |
7 | 13 | 1107.88 | 20 | 13.32 | 1053 | 281 | 1.07 / 1157.32 | 5 | 10 |
8 | 13 | 1056.92 | 20 | 13.30 | 1095 | 291 | 1.36 / 1157.61 | 5 | 15 |
9 | 13 | 996.24 | 20 | 13.49 | 1028 | 277 | 1.64 / 1157.88 | 5 | 31 |
10 | 13 | 910.76 | 20 | 13.53 | 944 | 255 | 1.89 / 1158.14 | 5 | 5 |
11 | 13 | 820.60 | 20 | 13.73 | 705 | 194 | 2.09 / 1158.33 | 5 | 8 |
12 | 13 | 722.28 | 20 | 13.52 | 735 | 199 | 2.29 / 1158.53 | 5 | 10 |
13 | 13 | 426.80 | 20 | 13.80 | 664 | 183 | 2.47 / 1158.71 | 5 | 39 |
14 | 13 | 104.52 | 20 | 14.00 | 400 | 112 | 2.58 / 1158.83 | 5 | 32 |
15 | 8 | -0.16 | 400 | 13.94 | 299 | 1667 | 4.25 / 1160.49 | 5 | 61 |
Average= | 20.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.60 | 29 | 13.99 | 467 | 189 | 0.19 / 1152.97 | 5 | 39 |
2 | 3 | 1031.20 | 1 | 11.50 | 1731 | 20 | 0.21 / 1152.99 | 5 | 5 |
3 | 7 | 1033.12 | 41 | 6.10 | 1517 | 379 | 0.59 / 1153.37 | 5 | 16 |
4 | 13 | 994.32 | 20 | 12.93 | 1686 | 436 | 1.02 / 1153.81 | 5 | 78 |
5 | 13 | 901.44 | 20 | 13.18 | 1530 | 403 | 1.43 / 1154.21 | 5 | 80 |
6 | 13 | 407.20 | 20 | 13.69 | 859 | 235 | 1.66 / 1154.45 | 5 | 80 |
7 | 13 | 41.16 | 20 | 14.04 | 372 | 104 | 1.77 / 1154.55 | 5 | 89 |
8 | 8 | -0.16 | 400 | 13.93 | 304 | 1694 | 3.46 / 1156.24 | 5 | 21 |
Average= | 21.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.76 | 49 | 14.01 | 401 | 275 | 0.28 / 1146.86 | 5 | 23 |
2 | 7 | 2008.16 | 40 | 4.57 | 1344 | 246 | 0.52 / 1147.11 | 23 | 6 |
3 | 13 | 2070.16 | 20 | 11.77 | 2291 | 539 | 1.06 / 1147.65 | 5 | 5 |
4 | 13 | 2057.32 | 20 | 12.15 | 2299 | 559 | 1.62 / 1148.21 | 5 | 5 |
5 | 13 | 1997.68 | 20 | 12.82 | 2058 | 528 | 2.15 / 1148.73 | 5 | 23 |
6 | 13 | 1914.80 | 20 | 12.97 | 2020 | 524 | 2.67 / 1149.26 | 5 | 34 |
7 | 13 | 1828.32 | 20 | 12.58 | 2130 | 536 | 3.21 / 1149.79 | 5 | 39 |
8 | 13 | 1729.36 | 20 | 13.02 | 1830 | 477 | 3.68 / 1150.27 | 5 | 42 |
9 | 13 | 1190.72 | 20 | 13.25 | 1445 | 383 | 4.07 / 1150.65 | 5 | 52 |
10 | 13 | 891.40 | 20 | 13.43 | 1179 | 317 | 4.38 / 1150.97 | 5 | 50 |
11 | 13 | 364.88 | 20 | 13.82 | 658 | 182 | 4.56 / 1151.15 | 5 | 49 |
12 | 13 | 15.72 | 20 | 14.09 | 325 | 92 | 4.66 / 1151.24 | 5 | 46 |
13 | 8 | 0.12 | 360 | 13.97 | 306 | 1539 | 6.20 / 1152.78 | 5 | 102 |
Average= | 21.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.44 | 61 | 13.93 | 394 | 335 | 0.33 / 1143.62 | 5 | 24 |
2 | 3 | 780.04 | -3 | 13.93 | 394 | 0 | 0.00 / 1143.62 | 5 | 24 |
3 | 7 | 916.12 | 40 | 7.27 | 1086 | 316 | 0.65 / 1143.94 | 24 | 8 |
4 | 13 | 862.04 | 20 | 13.25 | 1092 | 289 | 0.94 / 1144.23 | 5 | 29 |
5 | 13 | 784.20 | 20 | 13.18 | 1112 | 293 | 1.23 / 1144.52 | 5 | 36 |
6 | 13 | 594.28 | 20 | 13.73 | 799 | 219 | 1.45 / 1144.74 | 5 | 8 |
7 | 13 | 273.16 | 20 | 13.95 | 451 | 126 | 1.58 / 1144.87 | 5 | 9 |
8 | 13 | 41.32 | 20 | 14.05 | 343 | 96 | 1.67 / 1144.96 | 5 | 37 |
9 | 8 | 0.04 | 400 | 13.96 | 291 | 1625 | 3.30 / 1146.59 | 5 | 36 |
Average= | 21.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.68 | 37 | 14.05 | 353 | 184 | 0.18 / 1139.04 | 5 | 5 |
2 | 10 | 1020.76 | 6 | 12.96 | 1350 | 105 | 0.29 / 1139.15 | 5 | 5 |
3 | 10 | 1084.80 | 6 | 14.00 | 1233 | 104 | 0.39 / 1139.25 | 5 | 5 |
4 | 10 | 1134.36 | 5 | 13.49 | 1425 | 96 | 0.49 / 1139.35 | 5 | 5 |
5 | 10 | 1165.64 | 3 | 13.20 | 1929 | 76 | 0.56 / 1139.42 | 5 | 9 |
6 | 3 | 1199.20 | 5 | 12.34 | 1952 | 120 | 0.68 / 1139.54 | 5 | 35 |
7 | 7 | 1097.04 | 41 | 4.57 | 1379 | 258 | 0.94 / 1139.80 | 35 | 6 |
8 | 13 | 1099.88 | 20 | 13.37 | 1017 | 272 | 1.22 / 1140.07 | 5 | 6 |
9 | 13 | 1059.48 | 20 | 13.33 | 1086 | 290 | 1.50 / 1140.36 | 5 | 24 |
10 | 13 | 997.76 | 20 | 13.33 | 1128 | 301 | 1.81 / 1140.66 | 5 | 13 |
11 | 13 | 917.48 | 20 | 13.62 | 928 | 253 | 2.06 / 1140.92 | 5 | 25 |
12 | 13 | 822.96 | 20 | 13.57 | 893 | 242 | 2.30 / 1141.16 | 5 | 10 |
13 | 13 | 730.24 | 20 | 13.58 | 915 | 249 | 2.55 / 1141.41 | 5 | 35 |
14 | 13 | 309.00 | 20 | 13.92 | 575 | 160 | 2.71 / 1141.57 | 5 | 37 |
15 | 13 | 20.12 | 20 | 14.09 | 322 | 91 | 2.80 / 1141.66 | 5 | 34 |
16 | 8 | 0.20 | 399 | 13.99 | 292 | 1630 | 4.43 / 1143.29 | 5 | 21 |
Average= | 21.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.92 | 44 | 13.90 | 457 | 280 | 0.28 / 1135.97 | 5 | 54 |
2 | 3 | 371.56 | -10 | 13.90 | 457 | 0 | 0.00 / 1135.97 | 5 | 54 |
3 | 7 | 837.40 | 40 | 7.08 | 1362 | 386 | 0.67 / 1136.36 | 54 | 29 |
4 | 13 | 773.12 | 20 | 13.15 | 1407 | 370 | 1.04 / 1136.73 | 5 | 74 |
5 | 13 | 676.80 | 20 | 13.38 | 1251 | 335 | 1.37 / 1137.06 | 5 | 70 |
6 | 13 | 13.56 | 20 | 14.06 | 334 | 94 | 1.46 / 1137.15 | 5 | 84 |
7 | 8 | 0.08 | 400 | 13.92 | 306 | 1704 | 3.17 / 1138.86 | 5 | 37 |
Average= | 22.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.40 | 44 | 14.03 | 396 | 244 | 0.24 / 1129.65 | 5 | 9 |
2 | 10 | 1044.64 | 3 | 12.45 | 1473 | 55 | 0.30 / 1129.71 | 5 | 7 |
3 | 3 | 1076.32 | 2 | 11.64 | 1491 | 35 | 0.33 / 1129.74 | 5 | 5 |
4 | 7 | 2004.52 | 40 | 4.61 | 1496 | 276 | 0.61 / 1130.02 | 5 | 6 |
5 | 13 | 2045.40 | 20 | 11.75 | 2341 | 550 | 1.16 / 1130.57 | 5 | 5 |
6 | 13 | 2019.68 | 20 | 11.58 | 3031 | 702 | 1.86 / 1131.27 | 5 | 27 |
7 | 13 | 1961.88 | 20 | 11.94 | 2974 | 710 | 2.57 / 1131.98 | 5 | 56 |
8 | 13 | 1872.96 | 20 | 12.25 | 2833 | 694 | 3.27 / 1132.67 | 5 | 67 |
9 | 13 | 1555.00 | 20 | 12.72 | 2388 | 608 | 3.87 / 1133.28 | 5 | 80 |
10 | 13 | 1012.28 | 20 | 13.24 | 1633 | 432 | 4.31 / 1133.71 | 5 | 90 |
11 | 13 | 285.48 | 20 | 13.92 | 583 | 162 | 4.47 / 1133.88 | 5 | 53 |
12 | 13 | 20.16 | 20 | 14.07 | 335 | 94 | 4.56 / 1133.97 | 5 | 51 |
13 | 8 | 0.04 | 400 | 13.97 | 308 | 1721 | 6.28 / 1135.69 | 5 | 79 |
Average= | 22.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.64 | 31 | 13.97 | 420 | 182 | 0.18 / 1125.76 | 5 | 13 |
2 | 10 | 1045.12 | 4 | 12.66 | 1770 | 90 | 0.27 / 1125.85 | 5 | 22 |
3 | 3 | 1090.16 | 2 | 11.99 | 1819 | 44 | 0.32 / 1125.89 | 5 | 6 |
4 | 7 | 1047.88 | 40 | 5.07 | 1462 | 296 | 0.61 / 1126.19 | 6 | 5 |
5 | 13 | 1023.44 | 20 | 13.23 | 1192 | 315 | 0.93 / 1126.51 | 5 | 32 |
6 | 13 | 966.76 | 20 | 13.52 | 930 | 251 | 1.18 / 1126.76 | 5 | 5 |
7 | 13 | 893.52 | 20 | 13.52 | 1101 | 298 | 1.48 / 1127.06 | 5 | 41 |
8 | 13 | 797.52 | 20 | 13.51 | 915 | 247 | 1.72 / 1127.30 | 5 | 40 |
9 | 13 | 699.36 | 20 | 13.64 | 849 | 232 | 1.96 / 1127.53 | 5 | 9 |
10 | 13 | 483.36 | 20 | 13.77 | 716 | 197 | 2.15 / 1127.73 | 5 | 10 |
11 | 8 | 0.08 | 400 | 13.96 | 300 | 1675 | 3.83 / 1129.41 | 5 | 70 |
Average= | 23.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.96 | 35 | 13.92 | 465 | 227 | 0.23 / 1122.58 | 5 | 51 |
2 | 3 | 782.96 | -3 | 13.92 | 465 | 0 | 0.00 / 1122.58 | 5 | 51 |
3 | 7 | 912.56 | 40 | 6.30 | 1366 | 344 | 0.57 / 1122.93 | 51 | 18 |
4 | 13 | 873.56 | 20 | 12.95 | 1476 | 382 | 0.95 / 1123.31 | 5 | 63 |
5 | 13 | 780.28 | 20 | 13.25 | 1334 | 354 | 1.31 / 1123.66 | 5 | 64 |
6 | 13 | 363.68 | 20 | 13.72 | 802 | 220 | 1.53 / 1123.88 | 5 | 78 |
7 | 8 | 0.12 | 400 | 13.94 | 304 | 1695 | 3.22 / 1125.58 | 5 | 39 |
Average= | 23.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.24 | 43 | 13.94 | 398 | 239 | 0.24 / 1118.90 | 5 | 11 |
2 | 3 | 1046.24 | 1 | 12.01 | 1306 | 16 | 0.25 / 1118.91 | 5 | 5 |
3 | 7 | 1069.56 | 41 | 7.02 | 1675 | 482 | 0.74 / 1119.39 | 5 | 30 |
4 | 13 | 1005.68 | 20 | 13.33 | 1156 | 308 | 1.04 / 1119.70 | 5 | 7 |
5 | 13 | 922.04 | 20 | 13.34 | 1183 | 316 | 1.36 / 1120.02 | 5 | 42 |
6 | 13 | 720.72 | 20 | 13.58 | 923 | 251 | 1.61 / 1120.27 | 5 | 7 |
7 | 13 | 523.40 | 20 | 13.79 | 741 | 204 | 1.82 / 1120.47 | 5 | 9 |
8 | 13 | 20.84 | 20 | 14.09 | 325 | 92 | 1.91 / 1120.56 | 5 | 15 |
9 | 13 | 8.00 | 20 | 14.06 | 321 | 90 | 2.00 / 1120.65 | 5 | 42 |
10 | 8 | -0.04 | 400 | 13.96 | 305 | 1703 | 3.70 / 1122.36 | 5 | 67 |
Average= | 23.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.72 | 30 | 13.99 | 418 | 175 | 0.18 / 1112.23 | 5 | 8 |
2 | 10 | 1008.36 | 5 | 12.97 | 1345 | 87 | 0.26 / 1112.32 | 5 | 9 |
3 | 10 | 1050.28 | 4 | 13.29 | 1389 | 74 | 0.34 / 1112.39 | 5 | 10 |
4 | 10 | 1106.64 | 3 | 13.58 | 1317 | 54 | 0.39 / 1112.45 | 5 | 8 |
5 | 3 | 1119.96 | 3 | 12.23 | 1557 | 57 | 0.45 / 1112.50 | 5 | 8 |
6 | 7 | 2007.96 | 41 | 4.78 | 1596 | 313 | 0.76 / 1112.82 | 8 | 6 |
7 | 13 | 2056.16 | 20 | 12.04 | 2395 | 577 | 1.34 / 1113.39 | 5 | 5 |
8 | 13 | 2022.88 | 20 | 11.81 | 3024 | 714 | 2.05 / 1114.11 | 5 | 33 |
9 | 13 | 1945.72 | 20 | 12.13 | 2954 | 717 | 2.77 / 1114.83 | 5 | 59 |
10 | 13 | 1856.72 | 20 | 12.34 | 2833 | 699 | 3.47 / 1115.52 | 5 | 69 |
11 | 13 | 1460.56 | 20 | 12.80 | 2296 | 588 | 4.05 / 1116.11 | 5 | 85 |
12 | 13 | 1129.12 | 20 | 13.09 | 1861 | 487 | 4.54 / 1116.60 | 5 | 94 |
13 | 13 | 350.96 | 20 | 13.76 | 769 | 212 | 4.75 / 1116.81 | 5 | 79 |
14 | 13 | 11.40 | 20 | 14.07 | 339 | 95 | 4.85 / 1116.91 | 5 | 71 |
15 | 8 | 0.20 | 399 | 13.93 | 315 | 1751 | 6.60 / 1118.66 | 5 | 84 |
Average= | 24.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.00 | 30 | 13.94 | 411 | 172 | 0.17 / 1108.62 | 5 | 11 |
2 | 10 | 1030.56 | 4 | 12.67 | 1747 | 89 | 0.26 / 1108.70 | 5 | 22 |
3 | 3 | 1053.44 | 1 | 11.88 | 1801 | 21 | 0.28 / 1108.73 | 5 | 5 |
4 | 7 | 1040.20 | 40 | 5.39 | 1436 | 310 | 0.59 / 1109.04 | 5 | 7 |
5 | 13 | 999.36 | 20 | 13.08 | 1328 | 347 | 0.94 / 1109.38 | 5 | 40 |
6 | 13 | 931.12 | 20 | 13.25 | 1203 | 319 | 1.26 / 1109.70 | 5 | 44 |
7 | 13 | 837.52 | 20 | 13.27 | 1183 | 314 | 1.57 / 1110.02 | 5 | 40 |
8 | 13 | 529.80 | 20 | 13.80 | 755 | 208 | 1.78 / 1110.22 | 5 | 38 |
9 | 13 | 217.68 | 20 | 13.88 | 511 | 142 | 1.92 / 1110.37 | 5 | 32 |
10 | 8 | 0.20 | 400 | 13.91 | 304 | 1691 | 3.61 / 1112.06 | 8 | 74 |
Average= | 24.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.32 | 47 | 13.84 | 462 | 301 | 0.30 / 1105.63 | 5 | 58 |
2 | 3 | 312.28 | -11 | 13.84 | 462 | 0 | 0.00 / 1105.63 | 5 | 58 |
3 | 7 | 807.72 | 40 | 6.92 | 1285 | 356 | 0.66 / 1105.99 | 58 | 35 |
4 | 13 | 737.88 | 20 | 13.13 | 1312 | 345 | 1.00 / 1106.33 | 5 | 75 |
5 | 13 | 544.92 | 20 | 13.48 | 1029 | 277 | 1.28 / 1106.61 | 5 | 75 |
6 | 13 | 57.52 | 20 | 13.98 | 397 | 111 | 1.39 / 1106.72 | 5 | 69 |
7 | 8 | -0.04 | 400 | 13.88 | 310 | 1721 | 3.11 / 1108.44 | 5 | 74 |
Average= | 25.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.68 | 29 | 14.04 | 410 | 167 | 0.17 / 1101.93 | 5 | 5 |
2 | 10 | 1005.52 | 5 | 13.21 | 1230 | 81 | 0.25 / 1102.01 | 5 | 5 |
3 | 10 | 1044.92 | 4 | 13.89 | 1222 | 68 | 0.32 / 1102.08 | 5 | 6 |
4 | 10 | 1080.28 | 3 | 13.68 | 1335 | 55 | 0.37 / 1102.13 | 5 | 6 |
5 | 3 | 1100.32 | 2 | 12.44 | 1361 | 34 | 0.40 / 1102.17 | 5 | 5 |
6 | 7 | 1061.44 | 41 | 7.89 | 1326 | 429 | 0.83 / 1102.60 | 5 | 18 |
7 | 13 | 989.84 | 20 | 13.32 | 1208 | 322 | 1.16 / 1102.92 | 5 | 44 |
8 | 13 | 906.76 | 20 | 13.41 | 1134 | 304 | 1.46 / 1103.22 | 5 | 43 |
9 | 13 | 714.20 | 20 | 13.55 | 956 | 259 | 1.72 / 1103.48 | 5 | 21 |
10 | 13 | 409.92 | 20 | 13.88 | 536 | 149 | 1.87 / 1103.63 | 5 | 13 |
11 | 8 | 0.20 | 400 | 13.92 | 306 | 1704 | 3.57 / 1105.33 | 5 | 69 |
Average= | 25.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.72 | 36 | 13.89 | 460 | 230 | 0.23 / 1095.80 | 5 | 52 |
2 | 3 | 726.00 | -4 | 13.89 | 460 | 0 | 0.00 / 1095.80 | 5 | 52 |
3 | 7 | 2006.84 | 40 | 4.64 | 1639 | 304 | 0.53 / 1096.11 | 52 | 6 |
4 | 13 | 2042.36 | 20 | 11.02 | 3023 | 666 | 1.20 / 1096.77 | 5 | 5 |
5 | 13 | 2000.24 | 20 | 11.87 | 3014 | 716 | 1.92 / 1097.49 | 5 | 39 |
6 | 13 | 1933.84 | 20 | 12.19 | 2941 | 717 | 2.63 / 1098.20 | 5 | 61 |
7 | 13 | 1845.96 | 20 | 12.38 | 2827 | 700 | 3.33 / 1098.90 | 5 | 70 |
8 | 13 | 1413.12 | 20 | 12.86 | 2264 | 582 | 3.92 / 1099.49 | 5 | 86 |
9 | 13 | 876.96 | 20 | 13.30 | 1504 | 400 | 4.32 / 1099.89 | 5 | 92 |
10 | 13 | 114.32 | 20 | 13.98 | 482 | 135 | 4.45 / 1100.02 | 5 | 88 |
11 | 8 | 0.24 | 400 | 14.00 | 311 | 1742 | 6.19 / 1101.76 | 5 | 93 |
Average= | 26.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.80 | 41 | 13.88 | 426 | 242 | 0.24 / 1092.04 | 5 | 20 |
2 | 10 | 1011.44 | 3 | 12.75 | 1359 | 52 | 0.29 / 1092.09 | 5 | 14 |
3 | 10 | 1039.04 | 3 | 12.95 | 1785 | 69 | 0.36 / 1092.16 | 5 | 26 |
4 | 3 | 1039.32 | 1 | 11.87 | 1768 | 21 | 0.38 / 1092.19 | 5 | 5 |
5 | 7 | 1041.80 | 40 | 6.26 | 1501 | 376 | 0.76 / 1092.56 | 5 | 21 |
6 | 13 | 1002.28 | 20 | 13.25 | 1325 | 351 | 1.11 / 1092.91 | 5 | 31 |
7 | 13 | 936.52 | 20 | 13.24 | 1259 | 333 | 1.45 / 1093.25 | 5 | 39 |
8 | 13 | 844.48 | 20 | 13.44 | 1129 | 303 | 1.75 / 1093.55 | 5 | 17 |
9 | 13 | 438.64 | 20 | 13.74 | 733 | 201 | 1.95 / 1093.75 | 5 | 40 |
10 | 13 | 56.80 | 20 | 14.02 | 372 | 104 | 2.05 / 1093.85 | 5 | 46 |
11 | 8 | 0.00 | 400 | 13.93 | 308 | 1716 | 3.77 / 1095.57 | 5 | 98 |
Average= | 26.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.24 | 49 | 13.90 | 408 | 278 | 0.28 / 1088.61 | 5 | 18 |
2 | 3 | 705.28 | -5 | 13.90 | 408 | 0 | 0.00 / 1088.61 | 5 | 18 |
3 | 7 | 919.96 | 41 | 6.23 | 1362 | 348 | 0.63 / 1088.96 | 18 | 23 |
4 | 13 | 867.20 | 20 | 13.31 | 1099 | 293 | 0.92 / 1089.25 | 5 | 37 |
5 | 13 | 797.00 | 20 | 13.47 | 929 | 250 | 1.17 / 1089.50 | 5 | 9 |
6 | 13 | 699.32 | 20 | 13.64 | 680 | 186 | 1.35 / 1089.69 | 5 | 11 |
7 | 13 | 508.76 | 20 | 13.72 | 602 | 165 | 1.52 / 1089.85 | 5 | 12 |
8 | 13 | 413.28 | 20 | 13.73 | 703 | 193 | 1.71 / 1090.05 | 5 | 43 |
9 | 13 | 8.12 | 20 | 14.08 | 316 | 89 | 1.80 / 1090.14 | 5 | 39 |
10 | 8 | 0.16 | 400 | 13.96 | 298 | 1664 | 3.47 / 1091.80 | 5 | 44 |
Average= | 27.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.64 | 28 | 13.98 | 460 | 180 | 0.18 / 1085.16 | 5 | 39 |
2 | 3 | 1048.48 | 1 | 12.29 | 1756 | 22 | 0.20 / 1085.18 | 5 | 5 |
3 | 7 | 1032.92 | 40 | 7.47 | 1648 | 492 | 0.69 / 1085.67 | 5 | 36 |
4 | 13 | 955.32 | 20 | 13.11 | 1608 | 422 | 1.12 / 1086.09 | 5 | 74 |
5 | 13 | 758.04 | 20 | 13.40 | 1307 | 350 | 1.47 / 1086.44 | 5 | 76 |
6 | 13 | 213.04 | 20 | 13.88 | 610 | 169 | 1.64 / 1086.61 | 5 | 84 |
7 | 8 | 0.00 | 400 | 13.98 | 308 | 1722 | 3.36 / 1088.34 | 5 | 57 |
Average= | 27.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.76 | 36 | 13.95 | 404 | 203 | 0.20 / 1078.95 | 5 | 39 |
2 | 7 | 2003.96 | 40 | 4.66 | 1778 | 331 | 0.53 / 1079.28 | 39 | 5 |
3 | 13 | 2041.36 | 20 | 11.60 | 3016 | 700 | 1.23 / 1079.98 | 5 | 8 |
4 | 13 | 1995.88 | 20 | 12.21 | 2862 | 699 | 1.93 / 1080.68 | 5 | 41 |
5 | 13 | 1920.72 | 20 | 12.53 | 2565 | 643 | 2.58 / 1081.32 | 5 | 37 |
6 | 13 | 1828.60 | 20 | 12.79 | 2406 | 615 | 3.19 / 1081.94 | 5 | 43 |
7 | 13 | 1419.56 | 20 | 12.91 | 1931 | 499 | 3.69 / 1082.44 | 5 | 49 |
8 | 13 | 1116.84 | 20 | 13.52 | 1174 | 317 | 4.01 / 1082.75 | 5 | 12 |
9 | 13 | 707.40 | 20 | 13.67 | 951 | 260 | 4.27 / 1083.01 | 5 | 14 |
10 | 13 | 610.20 | 20 | 13.63 | 927 | 253 | 4.52 / 1083.27 | 5 | 44 |
11 | 8 | 0.08 | 400 | 14.03 | 305 | 1712 | 6.23 / 1084.98 | 5 | 79 |
Average= | 28.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.48 | 47 | 13.96 | 381 | 250 | 0.25 / 1075.29 | 5 | 6 |
2 | 3 | 1057.52 | 1 | 12.17 | 1286 | 16 | 0.27 / 1075.31 | 5 | 5 |
3 | 7 | 1025.48 | 41 | 8.14 | 1264 | 422 | 0.69 / 1075.73 | 5 | 34 |
4 | 13 | 967.04 | 20 | 13.49 | 922 | 249 | 0.94 / 1075.98 | 5 | 10 |
5 | 13 | 884.56 | 20 | 13.58 | 771 | 209 | 1.15 / 1076.19 | 5 | 5 |
6 | 13 | 811.40 | 20 | 13.52 | 911 | 246 | 1.39 / 1076.44 | 5 | 13 |
7 | 13 | 726.28 | 20 | 13.63 | 760 | 207 | 1.60 / 1076.64 | 5 | 10 |
8 | 13 | 543.52 | 20 | 13.76 | 654 | 180 | 1.78 / 1076.82 | 5 | 10 |
9 | 13 | 338.68 | 20 | 13.86 | 547 | 152 | 1.93 / 1076.98 | 5 | 9 |
10 | 13 | 113.84 | 20 | 13.99 | 397 | 111 | 2.04 / 1077.09 | 5 | 11 |
11 | 8 | 0.04 | 400 | 13.97 | 297 | 1660 | 3.70 / 1078.75 | 5 | 18 |
Average= | 29.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.08 | 71 | 13.80 | 454 | 445 | 0.44 / 1071.81 | 5 | 53 |
2 | 3 | 61.96 | -15 | 13.80 | 454 | 0 | 0.00 / 1071.81 | 5 | 53 |
3 | 7 | 1084.20 | 40 | 7.02 | 1572 | 441 | 0.89 / 1072.25 | 53 | 29 |
4 | 13 | 1027.64 | 20 | 12.95 | 1734 | 449 | 1.34 / 1072.70 | 5 | 78 |
5 | 13 | 842.52 | 20 | 13.26 | 1462 | 388 | 1.72 / 1073.09 | 5 | 81 |
6 | 13 | 435.92 | 20 | 13.64 | 921 | 251 | 1.97 / 1073.34 | 5 | 91 |
7 | 8 | 0.08 | 400 | 14.00 | 304 | 1702 | 3.68 / 1075.04 | 5 | 50 |
Average= | 29.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.04 | 30 | 14.02 | 436 | 183 | 0.18 / 1068.21 | 5 | 32 |
2 | 3 | 949.08 | -1 | 14.02 | 436 | 0 | 0.00 / 1068.21 | 5 | 32 |
3 | 7 | 983.44 | 40 | 8.45 | 1595 | 539 | 0.72 / 1068.75 | 32 | 49 |
4 | 13 | 913.96 | 20 | 13.38 | 1282 | 343 | 1.07 / 1069.09 | 5 | 15 |
5 | 13 | 817.56 | 20 | 13.54 | 1078 | 292 | 1.36 / 1069.38 | 5 | 50 |
6 | 13 | 288.08 | 20 | 13.79 | 610 | 168 | 1.53 / 1069.55 | 5 | 54 |
7 | 13 | 16.88 | 20 | 14.07 | 332 | 93 | 1.62 / 1069.64 | 5 | 60 |
8 | 8 | 0.00 | 400 | 13.94 | 309 | 1723 | 3.34 / 1071.37 | 5 | 72 |
Average= | 30.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.44 | 47 | 13.84 | 448 | 291 | 0.29 / 1062.06 | 5 | 51 |
2 | 3 | 553.60 | -7 | 13.84 | 448 | 0 | 0.00 / 1062.06 | 5 | 51 |
3 | 7 | 2008.36 | 40 | 4.87 | 2578 | 502 | 0.79 / 1062.56 | 51 | 5 |
4 | 13 | 2057.12 | 20 | 12.43 | 3071 | 763 | 1.56 / 1063.33 | 5 | 18 |
5 | 13 | 2018.12 | 20 | 12.53 | 3045 | 763 | 2.32 / 1064.09 | 5 | 54 |
6 | 13 | 1942.56 | 20 | 12.63 | 2918 | 737 | 3.06 / 1064.83 | 5 | 68 |
7 | 13 | 1542.48 | 20 | 12.90 | 2418 | 624 | 3.68 / 1065.45 | 5 | 82 |
8 | 13 | 1137.16 | 20 | 13.18 | 1882 | 496 | 4.18 / 1065.95 | 5 | 92 |
9 | 13 | 625.48 | 20 | 13.58 | 1113 | 302 | 4.48 / 1066.25 | 5 | 87 |
10 | 13 | 99.80 | 20 | 14.04 | 441 | 124 | 4.60 / 1066.37 | 5 | 70 |
11 | 8 | 0.12 | 381 | 14.05 | 309 | 1654 | 6.26 / 1068.03 | 5 | 137 |
Average= | 31.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.00 | 43 | 14.04 | 304 | 184 | 0.18 / 1056.60 | 5 | 5 |
2 | 10 | 1086.08 | 9 | 14.04 | 340 | 43 | 0.23 / 1056.64 | 5 | 5 |
3 | 10 | 1165.80 | 7 | 13.25 | 1031 | 96 | 0.32 / 1056.74 | 5 | 5 |
4 | 10 | 1238.80 | 7 | 13.12 | 1099 | 101 | 0.42 / 1056.84 | 5 | 5 |
5 | 3 | 1239.96 | 6 | 13.06 | 1077 | 84 | 0.51 / 1056.92 | 5 | 5 |
6 | 7 | 1593.28 | 41 | 12.92 | 1407 | 745 | 1.25 / 1057.67 | 5 | 5 |
7 | 13 | 1536.72 | 20 | 13.19 | 1573 | 415 | 1.67 / 1058.08 | 5 | 5 |
8 | 13 | 1460.56 | 20 | 13.16 | 1414 | 372 | 2.04 / 1058.46 | 5 | 5 |
9 | 13 | 1376.08 | 20 | 13.49 | 1349 | 364 | 2.40 / 1058.82 | 5 | 6 |
10 | 13 | 1285.56 | 20 | 13.09 | 1465 | 384 | 2.79 / 1059.20 | 5 | 18 |
11 | 13 | 994.28 | 20 | 13.35 | 1240 | 331 | 3.12 / 1059.53 | 5 | 33 |
12 | 13 | 694.56 | 20 | 13.58 | 967 | 263 | 3.38 / 1059.80 | 5 | 43 |
13 | 13 | 279.76 | 20 | 13.91 | 545 | 152 | 3.53 / 1059.95 | 5 | 9 |
14 | 13 | 87.12 | 20 | 14.01 | 399 | 112 | 3.64 / 1060.06 | 5 | 37 |
15 | 8 | 0.08 | 399 | 13.94 | 307 | 1708 | 5.35 / 1061.77 | 6 | 59 |
Average= | 32.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.12 | 44 | 13.89 | 420 | 257 | 0.26 / 1053.25 | 5 | 18 |
2 | 3 | 942.80 | -1 | 13.89 | 420 | 0 | 0.00 / 1053.25 | 5 | 18 |
3 | 7 | 986.96 | 40 | 8.53 | 1226 | 418 | 0.67 / 1053.67 | 18 | 25 |
4 | 13 | 920.32 | 20 | 13.30 | 1179 | 314 | 0.99 / 1053.98 | 5 | 50 |
5 | 13 | 832.64 | 20 | 13.06 | 1492 | 390 | 1.38 / 1054.37 | 5 | 91 |
6 | 13 | 310.44 | 20 | 13.70 | 751 | 206 | 1.58 / 1054.58 | 5 | 93 |
7 | 13 | 22.76 | 20 | 14.01 | 354 | 99 | 1.68 / 1054.68 | 5 | 91 |
8 | 8 | 0.20 | 400 | 13.87 | 313 | 1737 | 3.42 / 1056.42 | 5 | 62 |
Average= | 33.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.28 | 31 | 13.93 | 452 | 195 | 0.20 / 1050.07 | 5 | 47 |
2 | 3 | 923.60 | -1 | 13.93 | 452 | 0 | 0.00 / 1050.07 | 5 | 47 |
3 | 7 | 963.76 | 40 | 8.75 | 1576 | 552 | 0.75 / 1050.62 | 47 | 54 |
4 | 13 | 873.44 | 20 | 13.16 | 1500 | 395 | 1.14 / 1051.02 | 5 | 89 |
5 | 13 | 462.52 | 20 | 13.61 | 907 | 247 | 1.39 / 1051.26 | 5 | 81 |
6 | 8 | 0.00 | 400 | 13.88 | 312 | 1732 | 3.12 / 1053.00 | 5 | 92 |
Average= | 33.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.84 | 49 | 13.89 | 411 | 280 | 0.28 / 1043.73 | 5 | 24 |
2 | 3 | 940.76 | -1 | 13.89 | 411 | 0 | 0.00 / 1043.73 | 5 | 24 |
3 | 7 | 2005.24 | 40 | 4.75 | 2164 | 411 | 0.69 / 1044.14 | 24 | 5 |
4 | 13 | 2039.16 | 20 | 12.08 | 3041 | 735 | 1.43 / 1044.87 | 5 | 14 |
5 | 13 | 1982.96 | 20 | 12.39 | 2913 | 722 | 2.15 / 1045.59 | 5 | 48 |
6 | 13 | 1898.96 | 20 | 12.54 | 2613 | 655 | 2.80 / 1046.25 | 5 | 40 |
7 | 13 | 1800.68 | 20 | 12.69 | 2364 | 600 | 3.40 / 1046.85 | 5 | 23 |
8 | 13 | 1289.64 | 20 | 13.08 | 1684 | 441 | 3.84 / 1047.29 | 5 | 25 |
9 | 13 | 1094.04 | 20 | 13.42 | 1280 | 344 | 4.19 / 1047.63 | 5 | 15 |
10 | 13 | 886.00 | 20 | 13.52 | 1140 | 308 | 4.50 / 1047.94 | 5 | 18 |
11 | 13 | 359.08 | 20 | 13.86 | 653 | 181 | 4.68 / 1048.12 | 5 | 54 |
12 | 13 | 77.84 | 20 | 14.01 | 409 | 115 | 4.79 / 1048.24 | 5 | 57 |
13 | 8 | -0.12 | 380 | 13.96 | 309 | 1639 | 6.43 / 1049.88 | 5 | 76 |
Average= | 35.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.88 | 30 | 13.94 | 423 | 177 | 0.18 / 1039.43 | 5 | 5 |
2 | 10 | 1046.84 | 6 | 13.02 | 1453 | 114 | 0.29 / 1039.54 | 5 | 6 |
3 | 10 | 1088.00 | 4 | 13.30 | 1460 | 78 | 0.37 / 1039.62 | 5 | 5 |
4 | 3 | 1191.40 | 5 | 13.23 | 1357 | 90 | 0.46 / 1039.71 | 5 | 12 |
5 | 7 | 1125.56 | 40 | 7.51 | 1275 | 383 | 0.84 / 1040.09 | 12 | 19 |
6 | 13 | 1071.80 | 20 | 13.39 | 885 | 237 | 1.08 / 1040.33 | 5 | 5 |
7 | 13 | 1003.08 | 20 | 13.59 | 873 | 237 | 1.32 / 1040.57 | 5 | 21 |
8 | 13 | 928.96 | 20 | 13.60 | 834 | 227 | 1.54 / 1040.79 | 5 | 5 |
9 | 13 | 845.48 | 20 | 13.56 | 852 | 231 | 1.77 / 1041.02 | 5 | 23 |
10 | 13 | 750.52 | 20 | 13.55 | 903 | 245 | 2.02 / 1041.27 | 5 | 36 |
11 | 13 | 653.52 | 20 | 13.76 | 723 | 199 | 2.22 / 1041.47 | 5 | 10 |
12 | 13 | 346.96 | 20 | 13.82 | 577 | 159 | 2.38 / 1041.63 | 5 | 19 |
13 | 13 | 139.04 | 20 | 14.00 | 421 | 118 | 2.49 / 1041.75 | 5 | 12 |
14 | 8 | -0.04 | 400 | 13.94 | 305 | 1701 | 4.19 / 1043.45 | 5 | 50 |
Average= | 35.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.72 | 52 | 13.86 | 447 | 322 | 0.32 / 1036.32 | 5 | 55 |
2 | 3 | 99.52 | -14 | 13.86 | 447 | 0 | 0.00 / 1036.32 | 5 | 55 |
3 | 7 | 822.96 | 40 | 7.67 | 1363 | 418 | 0.74 / 1036.74 | 55 | 46 |
4 | 13 | 755.00 | 20 | 13.21 | 1361 | 360 | 1.10 / 1037.10 | 5 | 81 |
5 | 13 | 656.64 | 20 | 13.37 | 1186 | 317 | 1.42 / 1037.42 | 5 | 83 |
6 | 13 | 44.68 | 20 | 14.01 | 382 | 107 | 1.52 / 1037.52 | 5 | 92 |
7 | 8 | 0.28 | 400 | 13.93 | 310 | 1727 | 3.25 / 1039.25 | 5 | 59 |
Average= | 37.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.36 | 42 | 13.91 | 453 | 265 | 0.26 / 1033.16 | 5 | 47 |
2 | 3 | 573.52 | -7 | 13.91 | 453 | 0 | 0.00 / 1033.16 | 5 | 47 |
3 | 7 | 824.44 | 40 | 9.16 | 1401 | 513 | 0.78 / 1033.67 | 47 | 61 |
4 | 13 | 732.84 | 20 | 13.30 | 1268 | 337 | 1.12 / 1034.01 | 5 | 71 |
5 | 13 | 317.12 | 20 | 13.75 | 697 | 192 | 1.31 / 1034.20 | 5 | 66 |
6 | 13 | 1.16 | 20 | 14.09 | 312 | 88 | 1.39 / 1034.29 | 5 | 8 |
7 | 8 | -0.16 | 400 | 13.92 | 307 | 1709 | 3.10 / 1036.00 | 5 | 105 |
Average= | 38.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.04 | 44 | 13.94 | 397 | 244 | 0.24 / 1026.90 | 5 | 18 |
2 | 10 | 1010.32 | 4 | 13.83 | 1147 | 63 | 0.31 / 1026.96 | 5 | 18 |
3 | 3 | 1036.76 | 1 | 12.33 | 1278 | 16 | 0.32 / 1026.98 | 5 | 5 |
4 | 7 | 2002.96 | 40 | 7.42 | 2148 | 638 | 0.96 / 1027.62 | 5 | 5 |
5 | 13 | 1970.00 | 20 | 12.57 | 2318 | 583 | 1.54 / 1028.20 | 5 | 5 |
6 | 13 | 1902.40 | 20 | 12.89 | 2101 | 542 | 2.08 / 1028.74 | 5 | 5 |
7 | 13 | 1822.88 | 20 | 12.76 | 2193 | 560 | 2.64 / 1029.30 | 5 | 39 |
8 | 13 | 1733.60 | 20 | 12.78 | 2132 | 545 | 3.19 / 1029.85 | 5 | 45 |
9 | 13 | 1338.32 | 20 | 13.25 | 1549 | 410 | 3.60 / 1030.26 | 5 | 14 |
10 | 13 | 1039.36 | 20 | 13.43 | 1245 | 334 | 3.93 / 1030.59 | 5 | 14 |
11 | 13 | 943.80 | 20 | 13.69 | 939 | 257 | 4.19 / 1030.85 | 5 | 5 |
12 | 13 | 746.28 | 20 | 13.83 | 705 | 195 | 4.39 / 1031.04 | 5 | 17 |
13 | 13 | 447.60 | 20 | 13.84 | 583 | 161 | 4.55 / 1031.20 | 5 | 17 |
14 | 13 | 249.60 | 20 | 13.91 | 525 | 146 | 4.69 / 1031.35 | 5 | 12 |
15 | 13 | 4.56 | 20 | 14.10 | 323 | 91 | 4.78 / 1031.44 | 5 | 52 |
16 | 8 | 0.08 | 340 | 13.98 | 306 | 1454 | 6.24 / 1032.90 | 5 | 61 |
Average= | 39.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.12 | 28 | 14.09 | 355 | 140 | 0.14 / 1022.55 | 5 | 5 |
2 | 10 | 1052.92 | 7 | 14.02 | 409 | 40 | 0.18 / 1022.59 | 5 | 5 |
3 | 10 | 1116.88 | 6 | 13.91 | 435 | 36 | 0.22 / 1022.63 | 5 | 5 |
4 | 10 | 1160.40 | 4 | 13.96 | 873 | 49 | 0.27 / 1022.68 | 5 | 5 |
5 | 10 | 1190.20 | 3 | 14.22 | 854 | 36 | 0.30 / 1022.71 | 5 | 5 |
6 | 3 | 1209.40 | 5 | 13.97 | 877 | 61 | 0.36 / 1022.77 | 5 | 5 |
7 | 7 | 1235.36 | 40 | 13.55 | 782 | 424 | 0.79 / 1023.20 | 5 | 5 |
8 | 13 | 1178.92 | 20 | 13.66 | 739 | 202 | 0.99 / 1023.40 | 5 | 5 |
9 | 13 | 1124.92 | 20 | 13.59 | 849 | 231 | 1.22 / 1023.63 | 5 | 7 |
10 | 13 | 1056.84 | 20 | 13.59 | 895 | 243 | 1.46 / 1023.87 | 5 | 11 |
11 | 13 | 987.84 | 20 | 13.66 | 893 | 244 | 1.71 / 1024.12 | 5 | 10 |
12 | 13 | 908.40 | 20 | 13.60 | 861 | 234 | 1.94 / 1024.35 | 5 | 5 |
13 | 13 | 818.08 | 20 | 13.61 | 852 | 232 | 2.17 / 1024.58 | 5 | 17 |
14 | 13 | 724.88 | 20 | 13.65 | 755 | 206 | 2.38 / 1024.79 | 5 | 8 |
15 | 13 | 528.76 | 20 | 13.76 | 585 | 161 | 2.54 / 1024.95 | 5 | 10 |
16 | 13 | 122.80 | 20 | 14.00 | 379 | 106 | 2.65 / 1025.06 | 5 | 10 |
17 | 13 | 30.80 | 20 | 14.04 | 334 | 94 | 2.74 / 1025.15 | 5 | 15 |
18 | 8 | 0.12 | 360 | 13.94 | 300 | 1506 | 4.25 / 1026.66 | 5 | 5 |
Average= | 41.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.96 | 30 | 13.96 | 457 | 191 | 0.19 / 1019.32 | 5 | 40 |
2 | 3 | 939.96 | -1 | 13.96 | 457 | 0 | 0.00 / 1019.32 | 5 | 40 |
3 | 7 | 963.96 | 40 | 7.66 | 1537 | 471 | 0.66 / 1019.79 | 40 | 46 |
4 | 13 | 889.96 | 20 | 13.02 | 1567 | 408 | 1.07 / 1020.20 | 5 | 90 |
5 | 13 | 696.88 | 20 | 13.30 | 1297 | 345 | 1.42 / 1020.55 | 5 | 97 |
6 | 13 | 71.12 | 20 | 13.97 | 422 | 118 | 1.53 / 1020.67 | 5 | 96 |
7 | 8 | 0.28 | 400 | 13.90 | 314 | 1746 | 3.28 / 1022.41 | 5 | 39 |
Average= | 42.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.76 | 31 | 14.06 | 409 | 178 | 0.18 / 1015.69 | 5 | 7 |
2 | 10 | 1007.48 | 5 | 13.86 | 1169 | 81 | 0.26 / 1015.77 | 5 | 11 |
3 | 10 | 1051.28 | 4 | 13.22 | 1812 | 96 | 0.36 / 1015.86 | 5 | 40 |
4 | 3 | 1103.16 | 3 | 12.53 | 1871 | 70 | 0.43 / 1015.93 | 5 | 21 |
5 | 7 | 1057.64 | 40 | 8.43 | 1702 | 574 | 1.00 / 1016.51 | 21 | 53 |
6 | 13 | 978.96 | 20 | 13.30 | 1331 | 354 | 1.35 / 1016.86 | 5 | 43 |
7 | 13 | 885.84 | 20 | 13.32 | 1325 | 353 | 1.71 / 1017.21 | 5 | 52 |
8 | 13 | 346.76 | 20 | 13.73 | 744 | 204 | 1.91 / 1017.42 | 5 | 75 |
9 | 8 | 0.04 | 400 | 13.95 | 307 | 1713 | 3.62 / 1019.13 | 5 | 71 |
Average= | 44.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.12 | 61 | 13.82 | 414 | 349 | 0.35 / 1009.44 | 5 | 22 |
2 | 3 | 319.28 | -11 | 13.82 | 414 | 0 | 0.00 / 1009.44 | 5 | 22 |
3 | 7 | 2005.16 | 40 | 4.69 | 1898 | 356 | 0.71 / 1009.79 | 22 | 5 |
4 | 13 | 2045.40 | 20 | 11.78 | 3045 | 717 | 1.42 / 1010.51 | 5 | 8 |
5 | 13 | 1999.44 | 20 | 12.68 | 2290 | 581 | 2.00 / 1011.09 | 5 | 5 |
6 | 13 | 1929.60 | 20 | 12.77 | 2222 | 567 | 2.57 / 1011.66 | 5 | 6 |
7 | 13 | 1843.32 | 20 | 13.21 | 1820 | 481 | 3.05 / 1012.14 | 5 | 8 |
8 | 13 | 1547.12 | 20 | 13.04 | 1899 | 495 | 3.55 / 1012.63 | 5 | 43 |
9 | 13 | 1454.80 | 20 | 13.18 | 1571 | 414 | 3.96 / 1013.05 | 5 | 13 |
10 | 13 | 1139.40 | 20 | 13.58 | 1116 | 303 | 4.26 / 1013.35 | 5 | 8 |
11 | 13 | 824.48 | 20 | 13.64 | 888 | 242 | 4.51 / 1013.59 | 5 | 5 |
12 | 13 | 631.52 | 20 | 13.67 | 881 | 241 | 4.75 / 1013.83 | 5 | 52 |
13 | 13 | 112.20 | 20 | 13.99 | 435 | 122 | 4.87 / 1013.96 | 5 | 56 |
14 | 13 | 26.88 | 20 | 14.07 | 345 | 97 | 4.97 / 1014.05 | 5 | 49 |
15 | 8 | -0.08 | 340 | 13.99 | 306 | 1456 | 6.42 / 1015.51 | 5 | 60 |
Average= | 46.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.24 | 41 | 13.89 | 456 | 260 | 0.26 / 1006.17 | 5 | 50 |
2 | 3 | 567.04 | -7 | 13.89 | 456 | 0 | 0.00 / 1006.17 | 5 | 50 |
3 | 7 | 824.68 | 40 | 7.78 | 1403 | 437 | 0.70 / 1006.61 | 50 | 49 |
4 | 13 | 729.04 | 20 | 13.19 | 1314 | 347 | 1.04 / 1006.95 | 5 | 80 |
5 | 13 | 633.16 | 20 | 13.38 | 1142 | 306 | 1.35 / 1007.26 | 5 | 79 |
6 | 13 | 21.28 | 20 | 14.03 | 349 | 98 | 1.45 / 1007.36 | 5 | 86 |
7 | 8 | 0.04 | 400 | 13.90 | 311 | 1729 | 3.18 / 1009.09 | 6 | 73 |
Average= | 48.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.80 | 40 | 13.95 | 400 | 223 | 0.22 / 1002.78 | 5 | 7 |
2 | 7 | 1017.28 | 40 | 8.70 | 1252 | 436 | 0.66 / 1003.21 | 5 | 25 |
3 | 13 | 949.28 | 20 | 13.16 | 1229 | 323 | 0.98 / 1003.54 | 5 | 44 |
4 | 13 | 862.16 | 20 | 13.34 | 1096 | 292 | 1.27 / 1003.83 | 5 | 45 |
5 | 13 | 665.32 | 20 | 13.51 | 959 | 259 | 1.53 / 1004.09 | 5 | 44 |
6 | 13 | 76.32 | 20 | 13.95 | 404 | 113 | 1.65 / 1004.20 | 5 | 50 |
7 | 8 | 0.08 | 400 | 13.93 | 307 | 1711 | 3.36 / 1005.91 | 5 | 97 |
Average= | 50.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.44 | 40 | 13.97 | 461 | 258 | 0.26 / 999.70 | 5 | 41 |
2 | 3 | 589.12 | -6 | 13.97 | 461 | 0 | 0.00 / 999.70 | 5 | 41 |
3 | 7 | 803.44 | 41 | 9.20 | 1381 | 521 | 0.78 / 1000.22 | 41 | 59 |
4 | 13 | 715.88 | 20 | 13.27 | 1283 | 341 | 1.12 / 1000.56 | 5 | 83 |
5 | 13 | 184.88 | 20 | 13.83 | 554 | 153 | 1.27 / 1000.71 | 5 | 65 |
6 | 13 | 16.84 | 20 | 14.02 | 345 | 97 | 1.37 / 1000.81 | 5 | 64 |
7 | 8 | -0.08 | 400 | 13.89 | 314 | 1745 | 3.11 / 1002.55 | 5 | 57 |
Average= | 52.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.48 | 28 | 14.06 | 360 | 142 | 0.14 / 992.63 | 5 | 5 |
2 | 10 | 1093.36 | 7 | 13.05 | 1005 | 92 | 0.23 / 992.73 | 5 | 5 |
3 | 10 | 1157.80 | 6 | 14.14 | 754 | 64 | 0.30 / 992.79 | 5 | 5 |
4 | 10 | 1206.96 | 5 | 13.51 | 1469 | 99 | 0.40 / 992.89 | 5 | 5 |
5 | 10 | 1249.56 | 4 | 13.25 | 1481 | 78 | 0.48 / 992.97 | 5 | 6 |
6 | 10 | 1289.16 | 4 | 13.49 | 1465 | 79 | 0.55 / 993.05 | 5 | 6 |
7 | 3 | 1334.16 | 8 | 13.44 | 1423 | 153 | 0.71 / 993.20 | 5 | 26 |
8 | 7 | 2005.64 | 41 | 4.75 | 2147 | 418 | 1.13 / 993.62 | 26 | 5 |
9 | 13 | 2046.08 | 20 | 12.60 | 2334 | 588 | 1.71 / 994.21 | 5 | 5 |
10 | 13 | 2006.04 | 20 | 12.63 | 2671 | 675 | 2.39 / 994.88 | 5 | 17 |
11 | 13 | 1933.88 | 20 | 12.76 | 2369 | 605 | 2.99 / 995.49 | 5 | 9 |
12 | 13 | 1843.04 | 20 | 12.73 | 2431 | 619 | 3.61 / 996.10 | 5 | 26 |
13 | 13 | 1640.92 | 20 | 12.95 | 2157 | 559 | 4.17 / 996.66 | 5 | 45 |
14 | 13 | 1219.04 | 20 | 13.27 | 1581 | 420 | 4.59 / 997.08 | 5 | 17 |
15 | 13 | 911.44 | 20 | 13.45 | 1246 | 335 | 4.93 / 997.42 | 5 | 43 |
16 | 13 | 490.80 | 20 | 13.68 | 892 | 244 | 5.17 / 997.66 | 5 | 35 |
17 | 13 | 88.24 | 20 | 14.01 | 400 | 112 | 5.28 / 997.77 | 5 | 57 |
18 | 13 | 50.56 | 20 | 14.04 | 380 | 107 | 5.39 / 997.88 | 5 | 62 |
19 | 8 | 0.32 | 359 | 14.01 | 310 | 1559 | 6.95 / 999.44 | 5 | 79 |
Average= | 55.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.92 | 44 | 13.98 | 400 | 246 | 0.25 / 989.24 | 5 | 5 |
2 | 3 | 877.76 | -2 | 13.98 | 400 | 0 | 0.00 / 989.24 | 5 | 5 |
3 | 7 | 923.60 | 40 | 9.54 | 1179 | 450 | 0.70 / 989.69 | 5 | 33 |
4 | 13 | 857.04 | 20 | 13.30 | 998 | 265 | 0.96 / 989.95 | 5 | 10 |
5 | 13 | 772.76 | 20 | 13.62 | 804 | 219 | 1.18 / 990.17 | 5 | 5 |
6 | 13 | 678.52 | 20 | 13.63 | 785 | 214 | 1.39 / 990.38 | 5 | 11 |
7 | 13 | 388.96 | 20 | 13.77 | 593 | 163 | 1.56 / 990.55 | 5 | 9 |
8 | 13 | 93.84 | 20 | 14.00 | 386 | 108 | 1.67 / 990.66 | 5 | 10 |
9 | 13 | 22.84 | 20 | 14.04 | 337 | 95 | 1.76 / 990.75 | 5 | 39 |
10 | 13 | 10.28 | 20 | 14.02 | 325 | 91 | 1.85 / 990.84 | 5 | 40 |
11 | 8 | -0.28 | 400 | 13.95 | 296 | 1652 | 3.50 / 992.49 | 5 | 29 |
Average= | 58.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.36 | 35 | 14.03 | 398 | 195 | 0.20 / 985.44 | 5 | 7 |
2 | 10 | 1009.88 | 4 | 12.91 | 1453 | 75 | 0.27 / 985.52 | 5 | 10 |
3 | 10 | 1045.16 | 3 | 13.19 | 1463 | 58 | 0.33 / 985.57 | 5 | 10 |
4 | 3 | 1088.64 | 2 | 12.30 | 1516 | 37 | 0.37 / 985.61 | 5 | 5 |
5 | 7 | 1070.32 | 41 | 8.54 | 1312 | 459 | 0.83 / 986.07 | 5 | 25 |
6 | 13 | 999.08 | 20 | 13.14 | 1427 | 375 | 1.20 / 986.45 | 5 | 47 |
7 | 13 | 911.28 | 20 | 13.38 | 1215 | 325 | 1.53 / 986.77 | 5 | 45 |
8 | 13 | 606.84 | 20 | 13.50 | 1032 | 279 | 1.80 / 987.05 | 5 | 72 |
9 | 13 | 44.48 | 20 | 14.06 | 363 | 102 | 1.91 / 987.15 | 5 | 43 |
10 | 13 | 22.60 | 20 | 14.04 | 347 | 97 | 2.00 / 987.25 | 5 | 63 |
11 | 8 | 0.00 | 400 | 13.95 | 312 | 1741 | 3.74 / 988.99 | 5 | 90 |
Average= | 61.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.96 | 29 | 14.07 | 397 | 162 | 0.16 / 981.62 | 5 | 5 |
2 | 10 | 1003.68 | 5 | 13.05 | 1403 | 92 | 0.25 / 981.71 | 5 | 5 |
3 | 10 | 1047.60 | 4 | 13.27 | 1783 | 95 | 0.35 / 981.80 | 5 | 17 |
4 | 3 | 1088.64 | 2 | 12.46 | 1862 | 46 | 0.39 / 981.85 | 5 | 5 |
5 | 7 | 1048.08 | 41 | 10.51 | 1250 | 539 | 0.93 / 982.39 | 5 | 33 |
6 | 13 | 971.92 | 20 | 13.38 | 1042 | 279 | 1.21 / 982.67 | 5 | 21 |
7 | 13 | 886.44 | 20 | 13.59 | 917 | 249 | 1.46 / 982.92 | 5 | 28 |
8 | 13 | 790.80 | 20 | 13.63 | 884 | 241 | 1.70 / 983.16 | 5 | 20 |
9 | 13 | 486.60 | 20 | 13.80 | 583 | 161 | 1.86 / 983.32 | 5 | 12 |
10 | 13 | 285.60 | 20 | 13.88 | 540 | 150 | 2.01 / 983.47 | 5 | 37 |
11 | 13 | 19.56 | 20 | 14.06 | 335 | 94 | 2.11 / 983.56 | 5 | 50 |
12 | 8 | 0.20 | 400 | 13.98 | 301 | 1683 | 3.79 / 985.25 | 5 | 64 |
Average= | 65.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.72 | 30 | 13.94 | 451 | 189 | 0.19 / 975.39 | 5 | 35 |
2 | 3 | 950.64 | -1 | 13.94 | 451 | 0 | 0.00 / 975.39 | 5 | 35 |
3 | 7 | 2005.08 | 40 | 4.78 | 2306 | 441 | 0.63 / 975.83 | 35 | 5 |
4 | 13 | 2046.20 | 20 | 11.99 | 3066 | 735 | 1.36 / 976.56 | 5 | 10 |
5 | 13 | 1992.44 | 20 | 12.20 | 3018 | 736 | 2.10 / 977.30 | 5 | 50 |
6 | 13 | 1905.48 | 20 | 12.36 | 2907 | 719 | 2.82 / 978.02 | 5 | 67 |
7 | 13 | 1707.36 | 20 | 12.64 | 2613 | 661 | 3.48 / 978.68 | 5 | 76 |
8 | 13 | 1170.56 | 20 | 13.04 | 1920 | 501 | 3.98 / 979.18 | 5 | 92 |
9 | 13 | 568.76 | 20 | 13.51 | 1063 | 287 | 4.27 / 979.47 | 5 | 91 |
10 | 13 | 147.12 | 20 | 13.92 | 513 | 143 | 4.41 / 979.61 | 5 | 76 |
11 | 13 | 12.76 | 20 | 14.09 | 340 | 96 | 4.51 / 979.70 | 5 | 85 |
12 | 8 | -0.04 | 400 | 13.98 | 313 | 1750 | 6.26 / 981.45 | 5 | 95 |
Average= | 70.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.52 | 36 | 13.91 | 438 | 219 | 0.22 / 972.13 | 5 | 35 |
2 | 3 | 916.84 | -1 | 13.91 | 438 | 0 | 0.00 / 972.13 | 5 | 35 |
3 | 7 | 945.88 | 41 | 7.79 | 1532 | 489 | 0.71 / 972.62 | 35 | 47 |
4 | 13 | 867.24 | 20 | 13.26 | 1139 | 302 | 1.01 / 972.92 | 5 | 38 |
5 | 13 | 777.80 | 20 | 13.37 | 1032 | 276 | 1.29 / 973.20 | 5 | 36 |
6 | 13 | 471.48 | 20 | 13.67 | 738 | 202 | 1.49 / 973.40 | 5 | 41 |
7 | 13 | 38.60 | 20 | 14.01 | 356 | 100 | 1.59 / 973.50 | 5 | 47 |
8 | 8 | -0.08 | 400 | 13.92 | 305 | 1698 | 3.29 / 975.20 | 5 | 72 |
Average= | 75.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.04 | 33 | 14.08 | 398 | 185 | 0.18 / 968.34 | 5 | 6 |
2 | 10 | 1017.00 | 3 | 12.65 | 1437 | 55 | 0.24 / 968.39 | 5 | 5 |
3 | 3 | 1027.60 | 1 | 13.05 | 1223 | 16 | 0.26 / 968.41 | 5 | 5 |
4 | 7 | 1027.44 | 41 | 8.61 | 1245 | 439 | 0.69 / 968.85 | 5 | 11 |
5 | 13 | 967.72 | 20 | 13.51 | 790 | 213 | 0.91 / 969.06 | 5 | 5 |
6 | 13 | 904.12 | 20 | 13.35 | 1033 | 276 | 1.18 / 969.34 | 5 | 36 |
7 | 13 | 827.96 | 20 | 13.42 | 925 | 248 | 1.43 / 969.58 | 5 | 26 |
8 | 13 | 730.44 | 20 | 13.52 | 839 | 227 | 1.66 / 969.81 | 5 | 6 |
9 | 13 | 635.20 | 20 | 13.68 | 743 | 203 | 1.86 / 970.01 | 5 | 13 |
10 | 13 | 129.00 | 20 | 13.94 | 438 | 122 | 1.98 / 970.14 | 5 | 41 |
11 | 13 | 28.44 | 20 | 14.05 | 341 | 96 | 2.08 / 970.23 | 5 | 36 |
12 | 8 | 0.20 | 400 | 13.94 | 301 | 1678 | 3.76 / 971.91 | 5 | 31 |
Average= | 80.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.84 | 42 | 14.03 | 453 | 267 | 0.27 / 965.22 | 5 | 32 |
2 | 3 | 504.80 | -8 | 14.03 | 453 | 0 | 0.00 / 965.22 | 5 | 32 |
3 | 7 | 843.04 | 41 | 7.63 | 1417 | 443 | 0.71 / 965.67 | 32 | 42 |
4 | 13 | 771.12 | 20 | 13.13 | 1368 | 359 | 1.07 / 966.03 | 5 | 81 |
5 | 13 | 571.68 | 20 | 13.46 | 1047 | 282 | 1.35 / 966.31 | 5 | 77 |
6 | 13 | 55.76 | 20 | 13.98 | 391 | 109 | 1.46 / 966.42 | 5 | 48 |
7 | 8 | -0.20 | 400 | 13.94 | 311 | 1734 | 3.19 / 968.15 | 5 | 64 |
Average= | 88.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.60 | 40 | 13.95 | 443 | 247 | 0.25 / 959.05 | 5 | 29 |
2 | 3 | 556.80 | -7 | 13.95 | 443 | 0 | 0.00 / 959.05 | 5 | 29 |
3 | 7 | 2005.52 | 41 | 4.65 | 1698 | 324 | 0.57 / 959.37 | 29 | 5 |
4 | 13 | 2048.88 | 20 | 11.24 | 3027 | 680 | 1.25 / 960.05 | 5 | 5 |
5 | 13 | 2005.96 | 20 | 11.92 | 3023 | 721 | 1.97 / 960.77 | 5 | 38 |
6 | 13 | 1924.36 | 20 | 12.39 | 2715 | 673 | 2.64 / 961.44 | 5 | 41 |
7 | 13 | 1733.96 | 20 | 12.95 | 2079 | 538 | 3.18 / 961.98 | 5 | 22 |
8 | 13 | 1421.32 | 20 | 13.21 | 1794 | 474 | 3.66 / 962.46 | 5 | 34 |
9 | 13 | 1013.80 | 20 | 13.34 | 1377 | 367 | 4.02 / 962.82 | 5 | 31 |
10 | 13 | 707.88 | 20 | 13.48 | 1178 | 318 | 4.34 / 963.14 | 5 | 59 |
11 | 13 | 93.88 | 20 | 14.06 | 406 | 114 | 4.46 / 963.26 | 5 | 50 |
12 | 13 | 48.24 | 20 | 14.12 | 359 | 101 | 4.56 / 963.36 | 5 | 51 |
13 | 8 | 0.12 | 379 | 14.12 | 299 | 1600 | 6.16 / 964.96 | 5 | 74 |
Average= | 96.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.80 | 52 | 14.00 | 437 | 318 | 0.32 / 956.34 | 5 | 41 |
2 | 3 | 209.28 | -12 | 14.00 | 437 | 0 | 0.00 / 956.34 | 5 | 41 |
3 | 7 | 719.84 | 40 | 7.72 | 1215 | 375 | 0.69 / 956.71 | 41 | 23 |
4 | 13 | 636.76 | 20 | 13.24 | 1155 | 306 | 1.00 / 957.02 | 5 | 52 |
5 | 13 | 237.84 | 20 | 13.81 | 613 | 169 | 1.17 / 957.19 | 5 | 57 |
6 | 8 | 0.12 | 400 | 14.06 | 287 | 1614 | 2.78 / 958.80 | 5 | 41 |
Average= | 106.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.24 | 46 | 14.09 | 372 | 241 | 0.24 / 952.40 | 5 | 5 |
2 | 10 | 1023.24 | 3 | 12.76 | 1729 | 66 | 0.31 / 952.47 | 5 | 10 |
3 | 3 | 1109.20 | 3 | 12.13 | 1854 | 67 | 0.37 / 952.54 | 5 | 7 |
4 | 7 | 1060.32 | 41 | 9.85 | 1054 | 426 | 0.80 / 952.96 | 7 | 5 |
5 | 13 | 1014.20 | 20 | 13.43 | 987 | 265 | 1.07 / 953.23 | 5 | 13 |
6 | 13 | 944.08 | 20 | 13.53 | 847 | 229 | 1.29 / 953.46 | 5 | 7 |
7 | 13 | 864.80 | 20 | 13.39 | 917 | 246 | 1.54 / 953.70 | 5 | 7 |
8 | 13 | 772.64 | 20 | 13.59 | 903 | 245 | 1.79 / 953.95 | 5 | 26 |
9 | 13 | 473.56 | 20 | 13.71 | 747 | 205 | 1.99 / 954.15 | 5 | 29 |
10 | 13 | 168.00 | 20 | 14.04 | 449 | 126 | 2.12 / 954.28 | 5 | 27 |
11 | 13 | 17.08 | 20 | 14.18 | 313 | 89 | 2.21 / 954.37 | 5 | 27 |
12 | 8 | 0.20 | 400 | 14.12 | 292 | 1649 | 3.85 / 956.02 | 5 | 56 |
Average= | 119.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.72 | 43 | 14.01 | 420 | 253 | 0.25 / 949.04 | 5 | 8 |
2 | 3 | 957.00 | -1 | 14.01 | 420 | 0 | 0.00 / 949.04 | 5 | 8 |
3 | 7 | 1032.96 | 41 | 8.28 | 1675 | 569 | 0.82 / 949.61 | 8 | 39 |
4 | 13 | 950.08 | 20 | 13.09 | 1578 | 413 | 1.23 / 950.02 | 5 | 67 |
5 | 13 | 751.32 | 20 | 13.38 | 1280 | 343 | 1.58 / 950.37 | 5 | 66 |
6 | 13 | 109.12 | 20 | 14.03 | 461 | 129 | 1.71 / 950.50 | 5 | 77 |
7 | 8 | 0.24 | 400 | 14.12 | 295 | 1666 | 3.37 / 952.16 | 7 | 30 |
Average= | 136.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.52 | 28 | 14.05 | 409 | 161 | 0.16 / 942.36 | 5 | 5 |
2 | 10 | 1019.24 | 5 | 13.62 | 1197 | 82 | 0.24 / 942.44 | 5 | 7 |
3 | 10 | 1064.60 | 4 | 13.21 | 1814 | 96 | 0.34 / 942.54 | 5 | 31 |
4 | 3 | 1129.44 | 3 | 12.31 | 1908 | 70 | 0.41 / 942.61 | 5 | 23 |
5 | 7 | 2003.84 | 40 | 4.75 | 2176 | 413 | 0.82 / 943.02 | 23 | 5 |
6 | 13 | 2046.20 | 20 | 12.04 | 3065 | 738 | 1.56 / 943.76 | 5 | 8 |
7 | 13 | 1999.32 | 20 | 12.28 | 3036 | 746 | 2.31 / 944.51 | 5 | 48 |
8 | 13 | 1919.88 | 20 | 12.42 | 2941 | 731 | 3.04 / 945.24 | 5 | 67 |
9 | 13 | 1616.44 | 20 | 12.79 | 2544 | 651 | 3.69 / 945.89 | 5 | 79 |
10 | 13 | 1298.16 | 20 | 13.02 | 2098 | 546 | 4.23 / 946.43 | 5 | 88 |
11 | 13 | 742.80 | 20 | 13.43 | 1312 | 352 | 4.59 / 946.79 | 5 | 91 |
12 | 13 | 194.04 | 20 | 13.92 | 575 | 160 | 4.75 / 946.95 | 5 | 82 |
13 | 13 | 18.64 | 20 | 14.12 | 350 | 99 | 4.84 / 947.05 | 5 | 94 |
14 | 13 | 6.92 | 20 | 14.12 | 332 | 94 | 4.94 / 947.14 | 5 | 75 |
15 | 8 | -0.08 | 380 | 14.05 | 309 | 1650 | 6.59 / 948.79 | 5 | 67 |
Average= | 158.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.44 | 48 | 13.94 | 419 | 280 | 0.28 / 939.12 | 5 | 11 |
2 | 3 | 930.52 | -1 | 13.94 | 419 | 0 | 0.00 / 939.12 | 5 | 11 |
3 | 7 | 973.52 | 40 | 8.48 | 1287 | 437 | 0.72 / 939.56 | 11 | 25 |
4 | 13 | 898.80 | 20 | 13.26 | 1141 | 303 | 1.02 / 939.86 | 5 | 48 |
5 | 13 | 813.52 | 20 | 13.19 | 1350 | 356 | 1.38 / 940.22 | 5 | 83 |
6 | 13 | 497.32 | 20 | 13.53 | 939 | 254 | 1.63 / 940.47 | 5 | 73 |
7 | 8 | -0.28 | 400 | 13.92 | 311 | 1732 | 3.36 / 942.20 | 5 | 79 |
Average= | 188.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.32 | 49 | 14.01 | 392 | 269 | 0.27 / 935.72 | 5 | 19 |
2 | 3 | 967.60 | -1 | 14.01 | 392 | 0 | 0.00 / 935.72 | 5 | 19 |
3 | 7 | 1002.36 | 41 | 8.14 | 1577 | 526 | 0.80 / 936.25 | 19 | 47 |
4 | 13 | 908.52 | 20 | 13.27 | 1245 | 330 | 1.13 / 936.58 | 5 | 25 |
5 | 13 | 826.32 | 20 | 13.32 | 1193 | 318 | 1.44 / 936.90 | 5 | 45 |
6 | 13 | 295.32 | 20 | 13.79 | 657 | 181 | 1.62 / 937.08 | 5 | 59 |
7 | 13 | 20.16 | 20 | 14.08 | 335 | 94 | 1.72 / 937.17 | 5 | 56 |
8 | 8 | 0.04 | 400 | 14.00 | 298 | 1669 | 3.39 / 938.84 | 5 | 61 |
Average= | 234.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.44 | 41 | 14.04 | 411 | 237 | 0.24 / 931.93 | 5 | 6 |
2 | 3 | 1102.04 | 3 | 13.44 | 1285 | 52 | 0.29 / 931.99 | 5 | 5 |
3 | 7 | 1081.00 | 40 | 10.35 | 1303 | 539 | 0.83 / 932.53 | 5 | 37 |
4 | 13 | 1015.68 | 20 | 13.40 | 994 | 266 | 1.09 / 932.79 | 5 | 30 |
5 | 13 | 936.16 | 20 | 13.41 | 916 | 246 | 1.34 / 933.04 | 5 | 11 |
6 | 13 | 846.80 | 20 | 13.63 | 730 | 199 | 1.54 / 933.24 | 5 | 13 |
7 | 13 | 747.96 | 20 | 13.62 | 797 | 217 | 1.76 / 933.45 | 5 | 5 |
8 | 13 | 556.64 | 20 | 13.88 | 589 | 164 | 1.92 / 933.62 | 5 | 5 |
9 | 13 | 346.64 | 20 | 13.85 | 585 | 162 | 2.08 / 933.78 | 5 | 36 |
10 | 8 | -0.08 | 400 | 13.99 | 299 | 1673 | 3.75 / 935.45 | 5 | 61 |
Average= | 311.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.44 | 41 | 13.86 | 461 | 262 | 0.26 / 925.65 | 5 | 50 |
2 | 3 | 518.00 | -8 | 13.86 | 461 | 0 | 0.00 / 925.65 | 5 | 50 |
3 | 7 | 2012.16 | 41 | 4.76 | 2225 | 434 | 0.70 / 926.09 | 50 | 5 |
4 | 13 | 2055.72 | 20 | 12.02 | 3070 | 738 | 1.43 / 926.82 | 5 | 8 |
5 | 13 | 2004.16 | 20 | 12.29 | 3051 | 750 | 2.18 / 927.57 | 5 | 47 |
6 | 13 | 1916.12 | 20 | 12.46 | 2935 | 731 | 2.92 / 928.30 | 5 | 67 |
7 | 13 | 1612.32 | 20 | 12.82 | 2521 | 646 | 3.56 / 928.95 | 5 | 79 |
8 | 13 | 1187.64 | 20 | 13.13 | 1952 | 513 | 4.07 / 929.46 | 5 | 90 |
9 | 13 | 675.80 | 20 | 13.48 | 1225 | 330 | 4.40 / 929.79 | 5 | 93 |
10 | 13 | 27.44 | 20 | 14.10 | 365 | 103 | 4.51 / 929.90 | 5 | 89 |
11 | 8 | 0.20 | 400 | 14.02 | 321 | 1800 | 6.31 / 931.70 | 5 | 28 |
Average= | 465.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.88 | 51 | 13.95 | 412 | 293 | 0.29 / 922.38 | 5 | 29 |
2 | 3 | 932.08 | -1 | 13.95 | 412 | 0 | 0.00 / 922.38 | 5 | 29 |
3 | 7 | 958.96 | 40 | 9.29 | 1271 | 472 | 0.77 / 922.85 | 29 | 39 |
4 | 13 | 894.48 | 20 | 12.91 | 1395 | 360 | 1.13 / 923.21 | 5 | 49 |
5 | 13 | 694.60 | 20 | 13.35 | 999 | 267 | 1.39 / 923.48 | 5 | 54 |
6 | 13 | 382.92 | 20 | 13.74 | 682 | 187 | 1.58 / 923.66 | 5 | 56 |
7 | 8 | -0.08 | 400 | 13.92 | 310 | 1726 | 3.31 / 925.39 | 5 | 110 |
Average= | 925.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.08 | 28 | 13.97 | 452 | 177 | 0.18 / 918.43 | 5 | 6 |
2 | 10 | 1000.64 | 5 | 13.23 | 1375 | 91 | 0.27 / 918.52 | 5 | 8 |
3 | 10 | 1035.96 | 3 | 13.98 | 1205 | 51 | 0.32 / 918.57 | 5 | 6 |
4 | 10 | 1068.44 | 3 | 13.57 | 1306 | 53 | 0.37 / 918.62 | 5 | 6 |
5 | 3 | 1096.96 | 2 | 12.81 | 1507 | 39 | 0.41 / 918.66 | 5 | 5 |
6 | 7 | 1130.76 | 40 | 9.24 | 1414 | 523 | 0.93 / 919.19 | 5 | 29 |
7 | 13 | 1056.84 | 20 | 13.25 | 1306 | 346 | 1.28 / 919.53 | 5 | 51 |
8 | 13 | 971.40 | 20 | 13.27 | 1273 | 338 | 1.62 / 919.87 | 5 | 55 |
9 | 13 | 661.16 | 20 | 13.60 | 957 | 260 | 1.88 / 920.13 | 5 | 60 |
10 | 13 | 141.56 | 20 | 14.06 | 452 | 127 | 2.00 / 920.26 | 5 | 54 |
11 | 13 | 2.44 | 20 | 14.17 | 315 | 89 | 2.09 / 920.35 | 5 | 53 |
12 | 8 | 0.40 | 400 | 14.06 | 309 | 1738 | 3.83 / 922.08 | 5 | 67 |
Average= | 184.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.88 | 40 | 13.90 | 423 | 235 | 0.24 / 912.20 | 5 | 11 |
2 | 3 | 1020.00 | 1 | 12.20 | 1410 | 17 | 0.25 / 912.22 | 5 | 5 |
3 | 7 | 2005.76 | 40 | 6.34 | 2298 | 583 | 0.84 / 912.80 | 5 | 5 |
4 | 13 | 2032.92 | 20 | 12.36 | 2490 | 616 | 1.45 / 913.42 | 5 | 5 |
5 | 13 | 1990.24 | 20 | 12.76 | 2190 | 559 | 2.01 / 913.98 | 5 | 15 |
6 | 13 | 1916.08 | 20 | 12.76 | 2165 | 553 | 2.56 / 914.53 | 5 | 34 |
7 | 13 | 1818.88 | 20 | 13.01 | 2044 | 532 | 3.09 / 915.06 | 5 | 44 |
8 | 13 | 1615.48 | 20 | 13.33 | 1764 | 470 | 3.56 / 915.53 | 5 | 50 |
9 | 13 | 1191.48 | 20 | 13.29 | 1463 | 389 | 3.95 / 915.92 | 5 | 57 |
10 | 13 | 878.24 | 20 | 13.46 | 1176 | 317 | 4.27 / 916.24 | 5 | 61 |
11 | 13 | 364.80 | 20 | 13.74 | 773 | 212 | 4.48 / 916.45 | 5 | 79 |
12 | 13 | 15.56 | 20 | 14.06 | 353 | 99 | 4.58 / 916.55 | 5 | 59 |
13 | 8 | 0.00 | 380 | 13.93 | 322 | 1704 | 6.29 / 918.25 | 5 | 68 |
Average= | 229.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.56 | 34 | 13.94 | 426 | 202 | 0.20 / 908.39 | 5 | 9 |
2 | 10 | 1011.68 | 5 | 13.03 | 1395 | 91 | 0.29 / 908.48 | 5 | 11 |
3 | 3 | 1095.32 | 2 | 12.41 | 1492 | 37 | 0.33 / 908.52 | 5 | 5 |
4 | 7 | 1088.76 | 41 | 8.28 | 1403 | 476 | 0.81 / 909.00 | 5 | 26 |
5 | 13 | 1025.72 | 20 | 12.66 | 1686 | 427 | 1.23 / 909.42 | 5 | 67 |
6 | 13 | 933.60 | 20 | 13.09 | 1430 | 374 | 1.61 / 909.80 | 5 | 38 |
7 | 13 | 620.92 | 20 | 13.34 | 1164 | 311 | 1.92 / 910.11 | 5 | 94 |
8 | 13 | 80.24 | 20 | 13.96 | 424 | 118 | 2.04 / 910.23 | 5 | 62 |
9 | 8 | 0.16 | 400 | 13.90 | 313 | 1740 | 3.78 / 911.97 | 5 | 82 |
Average= | 303.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.80 | 42 | 13.90 | 443 | 259 | 0.26 / 905.40 | 5 | 32 |
2 | 3 | 653.20 | -5 | 13.90 | 443 | 0 | 0.00 / 905.40 | 5 | 32 |
3 | 7 | 795.00 | 41 | 8.75 | 1366 | 490 | 0.75 / 905.89 | 32 | 58 |
4 | 13 | 712.04 | 20 | 13.18 | 1205 | 318 | 1.07 / 906.21 | 5 | 60 |
5 | 13 | 401.40 | 20 | 13.57 | 829 | 225 | 1.29 / 906.44 | 5 | 78 |
6 | 8 | -0.04 | 400 | 13.84 | 317 | 1755 | 3.05 / 908.19 | 5 | 71 |
Average= | 454.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.80 | 27 | 14.00 | 487 | 184 | 0.18 / 901.90 | 5 | 48 |
2 | 7 | 999.56 | 41 | 8.92 | 1692 | 619 | 0.80 / 902.52 | 5 | 56 |
3 | 13 | 906.20 | 20 | 13.03 | 1583 | 413 | 1.22 / 902.93 | 5 | 91 |
4 | 13 | 597.04 | 20 | 13.42 | 1149 | 308 | 1.52 / 903.24 | 5 | 97 |
5 | 13 | 15.08 | 20 | 14.05 | 353 | 99 | 1.62 / 903.34 | 5 | 98 |
6 | 8 | 0.00 | 400 | 13.89 | 325 | 1806 | 3.43 / 905.14 | 5 | 49 |
Average= | 905.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.80 | 28 | 13.94 | 415 | 162 | 0.16 / 898.02 | 5 | 5 |
2 | 10 | 1055.28 | 5 | 13.04 | 1450 | 95 | 0.26 / 898.12 | 5 | 6 |
3 | 10 | 1100.52 | 4 | 13.17 | 1846 | 97 | 0.35 / 898.22 | 5 | 30 |
4 | 10 | 1129.28 | 3 | 13.27 | 1898 | 76 | 0.43 / 898.29 | 5 | 14 |
5 | 3 | 1100.20 | 2 | 12.71 | 1881 | 48 | 0.48 / 898.34 | 5 | 10 |
6 | 7 | 1057.92 | 41 | 7.85 | 1673 | 538 | 1.02 / 898.88 | 10 | 49 |
7 | 13 | 986.80 | 20 | 13.26 | 1269 | 337 | 1.35 / 899.21 | 5 | 42 |
8 | 13 | 899.76 | 20 | 13.44 | 1086 | 292 | 1.64 / 899.51 | 5 | 13 |
9 | 13 | 694.20 | 20 | 13.74 | 857 | 236 | 1.88 / 899.74 | 5 | 57 |
10 | 13 | 485.96 | 20 | 13.59 | 783 | 213 | 2.09 / 899.96 | 5 | 53 |
11 | 8 | 0.40 | 400 | 13.88 | 317 | 1760 | 3.85 / 901.72 | 5 | 63 |
Average= | 5.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.80 | 33 | 13.89 | 490 | 225 | 0.22 / 894.79 | 5 | 62 |
2 | 3 | 827.32 | -3 | 13.89 | 490 | 0 | 0.00 / 894.79 | 5 | 62 |
3 | 7 | 903.28 | 40 | 8.74 | 1530 | 535 | 0.76 / 895.32 | 62 | 61 |
4 | 13 | 817.16 | 20 | 12.99 | 1473 | 383 | 1.14 / 895.70 | 5 | 94 |
5 | 13 | 418.76 | 20 | 13.50 | 920 | 248 | 1.39 / 895.95 | 5 | 103 |
6 | 13 | 1.92 | 20 | 13.99 | 347 | 97 | 1.49 / 896.05 | 5 | 96 |
7 | 8 | 0.12 | 400 | 13.78 | 329 | 1813 | 3.30 / 897.86 | 5 | 24 |
Average= | 5.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.40 | 27 | 13.97 | 499 | 188 | 0.19 / 891.38 | 5 | 58 |
2 | 7 | 1011.52 | 41 | 8.93 | 1716 | 628 | 0.82 / 892.01 | 5 | 59 |
3 | 13 | 925.88 | 20 | 13.03 | 1617 | 421 | 1.24 / 892.43 | 5 | 93 |
4 | 13 | 604.28 | 20 | 13.40 | 1172 | 314 | 1.55 / 892.75 | 5 | 103 |
5 | 8 | 0.04 | 400 | 13.84 | 328 | 1816 | 3.37 / 894.56 | 5 | 122 |
Average= | 5.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.20 | 29 | 13.89 | 474 | 191 | 0.19 / 885.16 | 5 | 56 |
2 | 7 | 2002.60 | 40 | 7.30 | 2586 | 755 | 0.95 / 885.92 | 56 | 5 |
3 | 13 | 1991.76 | 20 | 12.23 | 3030 | 741 | 1.69 / 886.66 | 5 | 35 |
4 | 13 | 1923.72 | 20 | 12.45 | 2943 | 733 | 2.42 / 887.39 | 5 | 65 |
5 | 13 | 1830.60 | 20 | 12.60 | 2805 | 707 | 3.13 / 888.10 | 5 | 74 |
6 | 13 | 1513.28 | 20 | 12.89 | 2416 | 623 | 3.75 / 888.72 | 5 | 87 |
7 | 13 | 860.04 | 20 | 13.33 | 1511 | 403 | 4.15 / 889.12 | 5 | 102 |
8 | 13 | 427.68 | 20 | 13.66 | 898 | 245 | 4.40 / 889.37 | 5 | 103 |
9 | 8 | 0.36 | 400 | 13.90 | 328 | 1824 | 6.22 / 891.19 | 5 | 103 |
Average= | 5.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.40 | 28 | 13.97 | 443 | 173 | 0.17 / 881.45 | 5 | 24 |
2 | 10 | 1018.60 | 4 | 13.00 | 1761 | 92 | 0.26 / 881.54 | 5 | 35 |
3 | 3 | 1038.84 | 1 | 12.47 | 1802 | 22 | 0.29 / 881.56 | 5 | 5 |
4 | 7 | 1024.72 | 40 | 8.48 | 1654 | 561 | 0.85 / 882.13 | 5 | 58 |
5 | 13 | 942.08 | 20 | 13.33 | 1212 | 323 | 1.17 / 882.45 | 5 | 13 |
6 | 13 | 751.32 | 20 | 13.29 | 1126 | 299 | 1.47 / 882.75 | 5 | 24 |
7 | 13 | 452.72 | 20 | 13.62 | 789 | 215 | 1.69 / 882.96 | 5 | 16 |
8 | 13 | 69.24 | 20 | 13.95 | 407 | 114 | 1.80 / 883.08 | 5 | 56 |
9 | 13 | 4.80 | 20 | 14.00 | 344 | 96 | 1.90 / 883.17 | 5 | 78 |
10 | 8 | 0.00 | 400 | 13.80 | 326 | 1800 | 3.70 / 884.97 | 5 | 109 |
Average= | 5.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.44 | 30 | 13.91 | 500 | 209 | 0.21 / 878.24 | 5 | 58 |
2 | 3 | 914.52 | -1 | 13.91 | 500 | 0 | 0.00 / 878.24 | 5 | 58 |
3 | 7 | 943.12 | 40 | 8.74 | 1590 | 556 | 0.76 / 878.80 | 58 | 60 |
4 | 13 | 859.80 | 20 | 13.04 | 1524 | 397 | 1.16 / 879.20 | 5 | 93 |
5 | 13 | 452.48 | 20 | 13.52 | 959 | 259 | 1.42 / 879.46 | 5 | 100 |
6 | 8 | 0.08 | 400 | 13.83 | 329 | 1820 | 3.24 / 881.28 | 5 | 112 |
Average= | 5.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.68 | 30 | 13.98 | 499 | 209 | 0.21 / 874.95 | 5 | 55 |
2 | 3 | 893.64 | -2 | 13.98 | 499 | 0 | 0.00 / 874.95 | 5 | 55 |
3 | 7 | 947.92 | 40 | 9.42 | 1619 | 610 | 0.82 / 875.56 | 55 | 64 |
4 | 13 | 859.12 | 20 | 13.13 | 1525 | 400 | 1.22 / 875.96 | 5 | 94 |
5 | 13 | 436.20 | 20 | 13.58 | 932 | 253 | 1.47 / 876.21 | 5 | 100 |
6 | 8 | -0.24 | 400 | 13.86 | 329 | 1824 | 3.30 / 878.04 | 5 | 118 |
Average= | 5.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.16 | 38 | 13.88 | 498 | 263 | 0.26 / 869.12 | 5 | 67 |
2 | 3 | 621.56 | -6 | 13.88 | 498 | 0 | 0.00 / 869.12 | 5 | 67 |
3 | 7 | 2004.72 | 40 | 8.01 | 2879 | 922 | 1.19 / 870.05 | 67 | 5 |
4 | 13 | 1959.20 | 20 | 12.59 | 2986 | 752 | 1.94 / 870.80 | 5 | 59 |
5 | 13 | 1879.12 | 20 | 12.69 | 2879 | 731 | 2.67 / 871.53 | 5 | 73 |
6 | 13 | 1474.32 | 20 | 12.98 | 2355 | 611 | 3.28 / 872.14 | 5 | 87 |
7 | 13 | 1057.28 | 20 | 13.24 | 1791 | 474 | 3.75 / 872.61 | 5 | 99 |
8 | 13 | 520.48 | 20 | 13.59 | 1049 | 285 | 4.04 / 872.90 | 5 | 103 |
9 | 8 | 0.24 | 400 | 13.94 | 330 | 1840 | 5.88 / 874.74 | 5 | 107 |
Average= | 5.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.08 | 39 | 13.90 | 485 | 263 | 0.26 / 866.09 | 5 | 64 |
2 | 3 | 594.04 | -6 | 13.90 | 485 | 0 | 0.00 / 866.09 | 5 | 64 |
3 | 7 | 762.60 | 41 | 12.82 | 1354 | 712 | 0.97 / 866.80 | 64 | 83 |
4 | 13 | 452.60 | 20 | 13.62 | 916 | 250 | 1.22 / 867.05 | 5 | 85 |
5 | 8 | 0.28 | 400 | 13.88 | 326 | 1810 | 3.03 / 868.86 | 5 | 111 |
Average= | 5.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.28 | 32 | 13.96 | 445 | 199 | 0.20 / 862.32 | 5 | 14 |
2 | 10 | 1007.12 | 3 | 12.92 | 1410 | 55 | 0.25 / 862.37 | 5 | 6 |
3 | 10 | 1034.20 | 2 | 13.23 | 1506 | 40 | 0.29 / 862.41 | 5 | 5 |
4 | 3 | 1086.28 | 2 | 12.54 | 1521 | 38 | 0.33 / 862.45 | 5 | 5 |
5 | 7 | 1050.12 | 41 | 12.87 | 1327 | 700 | 1.03 / 863.15 | 5 | 49 |
6 | 13 | 958.08 | 20 | 13.34 | 1294 | 345 | 1.38 / 863.50 | 5 | 56 |
7 | 13 | 574.36 | 20 | 13.65 | 893 | 244 | 1.62 / 863.74 | 5 | 62 |
8 | 13 | 269.40 | 20 | 13.83 | 610 | 169 | 1.79 / 863.91 | 5 | 65 |
9 | 13 | 37.16 | 20 | 14.04 | 383 | 108 | 1.90 / 864.02 | 5 | 69 |
10 | 8 | 0.16 | 400 | 13.89 | 326 | 1811 | 3.71 / 865.83 | 5 | 95 |
Average= | 5.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.20 | 39 | 13.96 | 479 | 261 | 0.26 / 859.17 | 5 | 63 |
2 | 3 | 620.60 | -6 | 13.96 | 479 | 0 | 0.00 / 859.17 | 5 | 63 |
3 | 7 | 771.68 | 40 | 13.13 | 1337 | 702 | 0.96 / 859.87 | 63 | 81 |
4 | 13 | 444.20 | 20 | 13.65 | 915 | 250 | 1.21 / 860.12 | 5 | 87 |
5 | 13 | 27.92 | 20 | 14.05 | 374 | 105 | 1.32 / 860.23 | 5 | 97 |
6 | 13 | 15.04 | 20 | 14.03 | 355 | 100 | 1.42 / 860.33 | 5 | 85 |
7 | 8 | 0.08 | 400 | 13.90 | 322 | 1790 | 3.21 / 862.12 | 5 | 76 |
Average= | 5.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.84 | 33 | 14.02 | 421 | 195 | 0.19 / 853.07 | 5 | 9 |
2 | 10 | 1022.16 | 3 | 13.04 | 1385 | 54 | 0.25 / 853.12 | 5 | 7 |
3 | 3 | 1068.84 | 2 | 12.59 | 1398 | 35 | 0.28 / 853.16 | 5 | 5 |
4 | 7 | 2003.20 | 40 | 8.64 | 2958 | 1022 | 1.31 / 854.18 | 5 | 9 |
5 | 13 | 1946.84 | 20 | 12.60 | 2977 | 750 | 2.06 / 854.93 | 5 | 63 |
6 | 13 | 1852.48 | 20 | 12.75 | 2803 | 715 | 2.77 / 855.65 | 5 | 73 |
7 | 13 | 1528.24 | 20 | 13.00 | 2387 | 621 | 3.39 / 856.27 | 5 | 86 |
8 | 13 | 1001.00 | 20 | 13.29 | 1604 | 426 | 3.82 / 856.69 | 5 | 75 |
9 | 13 | 674.92 | 20 | 13.65 | 983 | 268 | 4.09 / 856.96 | 5 | 63 |
10 | 13 | 61.56 | 20 | 14.04 | 419 | 118 | 4.20 / 857.08 | 5 | 77 |
11 | 8 | -0.16 | 400 | 13.95 | 328 | 1830 | 6.03 / 858.91 | 5 | 84 |
Average= | 5.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.72 | 40 | 13.98 | 467 | 261 | 0.26 / 850.04 | 5 | 48 |
2 | 3 | 658.92 | -5 | 13.98 | 467 | 0 | 0.00 / 850.04 | 5 | 48 |
3 | 7 | 804.68 | 41 | 12.87 | 1282 | 676 | 0.94 / 850.71 | 48 | 74 |
4 | 13 | 608.60 | 20 | 13.50 | 1124 | 303 | 1.24 / 851.02 | 5 | 86 |
5 | 13 | 8.72 | 20 | 14.10 | 335 | 94 | 1.34 / 851.11 | 5 | 80 |
6 | 8 | 0.16 | 400 | 13.95 | 316 | 1763 | 3.10 / 852.88 | 5 | 68 |
Average= | 5.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.84 | 30 | 14.09 | 423 | 179 | 0.18 / 846.14 | 5 | 5 |
2 | 10 | 1044.08 | 4 | 13.12 | 1402 | 74 | 0.25 / 846.22 | 5 | 6 |
3 | 10 | 1083.00 | 4 | 13.32 | 1837 | 98 | 0.35 / 846.31 | 5 | 27 |
4 | 3 | 1081.12 | 2 | 12.62 | 1859 | 47 | 0.40 / 846.36 | 5 | 6 |
5 | 7 | 1047.24 | 41 | 13.04 | 1254 | 670 | 1.07 / 847.03 | 6 | 47 |
6 | 13 | 963.56 | 20 | 13.39 | 1170 | 313 | 1.38 / 847.35 | 5 | 12 |
7 | 13 | 779.44 | 20 | 13.61 | 1016 | 277 | 1.66 / 847.62 | 5 | 44 |
8 | 13 | 378.68 | 20 | 13.76 | 665 | 183 | 1.84 / 847.80 | 5 | 43 |
9 | 13 | 88.48 | 20 | 14.02 | 409 | 115 | 1.96 / 847.92 | 5 | 38 |
10 | 13 | 20.88 | 20 | 14.09 | 345 | 97 | 2.05 / 848.02 | 5 | 66 |
11 | 8 | 0.20 | 400 | 13.97 | 315 | 1760 | 3.81 / 849.78 | 5 | 65 |
Average= | 5.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.24 | 30 | 14.13 | 420 | 178 | 0.18 / 842.36 | 5 | 6 |
2 | 10 | 1049.48 | 4 | 13.03 | 1486 | 77 | 0.26 / 842.44 | 5 | 9 |
3 | 10 | 1079.20 | 3 | 13.29 | 1860 | 74 | 0.33 / 842.51 | 5 | 22 |
4 | 3 | 1105.80 | 3 | 12.84 | 1915 | 74 | 0.40 / 842.59 | 5 | 23 |
5 | 7 | 1054.32 | 40 | 12.89 | 1730 | 892 | 1.30 / 843.48 | 23 | 83 |
6 | 13 | 857.72 | 20 | 13.34 | 1507 | 402 | 1.70 / 843.88 | 5 | 94 |
7 | 13 | 321.88 | 20 | 13.84 | 657 | 182 | 1.88 / 844.06 | 5 | 62 |
8 | 13 | 24.24 | 20 | 14.09 | 358 | 101 | 1.98 / 844.16 | 5 | 98 |
9 | 8 | -0.08 | 400 | 13.97 | 322 | 1799 | 3.78 / 845.96 | 5 | 90 |
Average= | 5.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.88 | 41 | 14.02 | 437 | 251 | 0.25 / 836.28 | 5 | 34 |
2 | 3 | 692.96 | -5 | 14.02 | 437 | 0 | 0.00 / 836.28 | 5 | 34 |
3 | 7 | 2008.04 | 40 | 8.06 | 2956 | 953 | 1.20 / 837.24 | 34 | 6 |
4 | 13 | 1959.84 | 20 | 12.72 | 2595 | 660 | 1.86 / 837.90 | 5 | 20 |
5 | 13 | 1881.44 | 20 | 12.91 | 2279 | 588 | 2.45 / 838.49 | 5 | 15 |
6 | 13 | 1783.76 | 20 | 13.07 | 2065 | 540 | 2.99 / 839.03 | 5 | 13 |
7 | 13 | 1473.84 | 20 | 13.41 | 1603 | 430 | 3.42 / 839.46 | 5 | 10 |
8 | 13 | 1067.72 | 20 | 13.54 | 1354 | 367 | 3.79 / 839.82 | 5 | 58 |
9 | 13 | 773.28 | 20 | 13.57 | 1067 | 290 | 4.08 / 840.11 | 5 | 35 |
10 | 13 | 352.88 | 20 | 13.88 | 656 | 182 | 4.26 / 840.29 | 5 | 13 |
11 | 13 | 36.92 | 20 | 14.10 | 364 | 103 | 4.36 / 840.40 | 5 | 59 |
12 | 13 | 2.60 | 20 | 14.14 | 331 | 94 | 4.46 / 840.49 | 5 | 73 |
13 | 8 | 0.04 | 380 | 14.02 | 318 | 1694 | 6.15 / 842.18 | 5 | 69 |
Average= | 5.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.48 | 29 | 14.07 | 441 | 180 | 0.18 / 832.69 | 5 | 17 |
2 | 3 | 1060.76 | 2 | 12.54 | 1818 | 46 | 0.23 / 832.74 | 5 | 5 |
3 | 7 | 1022.16 | 40 | 12.73 | 1392 | 709 | 0.93 / 833.45 | 5 | 45 |
4 | 13 | 926.32 | 20 | 13.33 | 1244 | 332 | 1.27 / 833.78 | 5 | 14 |
5 | 13 | 720.28 | 20 | 13.53 | 1076 | 291 | 1.56 / 834.07 | 5 | 19 |
6 | 13 | 279.28 | 20 | 13.81 | 672 | 186 | 1.74 / 834.25 | 5 | 75 |
7 | 8 | 0.12 | 400 | 13.94 | 319 | 1779 | 3.52 / 836.03 | 5 | 114 |
Average= | 5.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.08 | 29 | 14.04 | 473 | 193 | 0.19 / 829.38 | 5 | 43 |
2 | 7 | 994.64 | 41 | 12.72 | 1585 | 827 | 1.02 / 830.20 | 43 | 50 |
3 | 13 | 792.00 | 20 | 13.34 | 1388 | 370 | 1.39 / 830.57 | 5 | 94 |
4 | 13 | 147.08 | 20 | 13.92 | 515 | 143 | 1.53 / 830.72 | 5 | 76 |
5 | 8 | -0.12 | 400 | 13.94 | 322 | 1795 | 3.33 / 832.51 | 5 | 118 |
Average= | 5.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.12 | 29 | 14.12 | 444 | 182 | 0.18 / 825.92 | 5 | 20 |
2 | 3 | 1059.88 | 1 | 12.80 | 1781 | 23 | 0.20 / 825.94 | 5 | 5 |
3 | 7 | 1012.08 | 40 | 13.06 | 1404 | 733 | 0.94 / 826.67 | 5 | 45 |
4 | 13 | 919.04 | 20 | 13.43 | 1397 | 375 | 1.31 / 827.05 | 5 | 59 |
5 | 13 | 513.00 | 20 | 13.60 | 970 | 264 | 1.58 / 827.31 | 5 | 75 |
6 | 13 | 42.68 | 20 | 14.07 | 374 | 105 | 1.68 / 827.42 | 5 | 57 |
7 | 8 | 0.12 | 400 | 13.98 | 316 | 1767 | 3.45 / 829.18 | 5 | 69 |
Average= | 5.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.12 | 29 | 14.11 | 431 | 176 | 0.18 / 819.74 | 5 | 6 |
2 | 10 | 1005.32 | 5 | 13.94 | 1163 | 81 | 0.26 / 819.82 | 5 | 12 |
3 | 10 | 1038.64 | 3 | 13.50 | 1295 | 52 | 0.31 / 819.87 | 5 | 7 |
4 | 10 | 1066.32 | 3 | 14.09 | 1215 | 51 | 0.36 / 819.92 | 5 | 5 |
5 | 3 | 1074.52 | 2 | 12.91 | 1453 | 38 | 0.40 / 819.96 | 5 | 5 |
6 | 7 | 2003.52 | 40 | 7.12 | 2713 | 773 | 1.17 / 820.73 | 5 | 5 |
7 | 13 | 1966.56 | 20 | 12.44 | 2995 | 745 | 1.92 / 821.48 | 5 | 50 |
8 | 13 | 1888.36 | 20 | 12.61 | 2876 | 725 | 2.64 / 822.21 | 5 | 69 |
9 | 13 | 1696.16 | 20 | 12.82 | 2607 | 668 | 3.31 / 822.87 | 5 | 80 |
10 | 13 | 1184.04 | 20 | 13.14 | 1952 | 513 | 3.82 / 823.39 | 5 | 93 |
11 | 13 | 762.60 | 20 | 13.51 | 1084 | 293 | 4.12 / 823.68 | 5 | 61 |
12 | 13 | 244.52 | 20 | 13.94 | 572 | 159 | 4.28 / 823.84 | 5 | 64 |
13 | 13 | 29.68 | 20 | 14.12 | 364 | 103 | 4.38 / 823.94 | 5 | 64 |
14 | 8 | 0.16 | 400 | 14.00 | 320 | 1792 | 6.17 / 825.73 | 5 | 93 |
Average= | 5.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.96 | 29 | 14.10 | 482 | 197 | 0.20 / 813.83 | 5 | 41 |
2 | 3 | 960.20 | -1 | 14.10 | 482 | 0 | 0.00 / 813.83 | 5 | 41 |
3 | 7 | 2002.88 | 41 | 7.29 | 2713 | 811 | 1.01 / 814.64 | 41 | 5 |
4 | 13 | 1961.28 | 20 | 12.44 | 2985 | 743 | 1.75 / 815.39 | 5 | 52 |
5 | 13 | 1881.76 | 20 | 12.61 | 2863 | 722 | 2.47 / 816.11 | 5 | 70 |
6 | 13 | 1690.88 | 20 | 12.79 | 2614 | 669 | 3.14 / 816.78 | 5 | 80 |
7 | 13 | 1177.12 | 20 | 13.13 | 1918 | 504 | 3.65 / 817.28 | 5 | 94 |
8 | 13 | 760.60 | 20 | 13.44 | 1297 | 349 | 3.99 / 817.63 | 5 | 74 |
9 | 13 | 116.04 | 20 | 14.01 | 487 | 136 | 4.13 / 817.76 | 5 | 88 |
10 | 8 | 0.04 | 400 | 14.01 | 321 | 1799 | 5.93 / 819.56 | 5 | 83 |
Average= | 5.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.64 | 39 | 14.03 | 484 | 265 | 0.26 / 807.79 | 5 | 60 |
2 | 3 | 581.68 | -7 | 14.03 | 484 | 0 | 0.00 / 807.79 | 5 | 60 |
3 | 7 | 2008.24 | 40 | 7.70 | 2706 | 833 | 1.10 / 808.62 | 60 | 5 |
4 | 13 | 1964.52 | 20 | 12.49 | 3011 | 752 | 1.85 / 809.37 | 5 | 53 |
5 | 13 | 1886.96 | 20 | 12.66 | 2892 | 732 | 2.58 / 810.11 | 5 | 71 |
6 | 13 | 1690.24 | 20 | 12.85 | 2631 | 676 | 3.26 / 810.78 | 5 | 81 |
7 | 13 | 1159.56 | 20 | 13.17 | 1915 | 504 | 3.76 / 811.29 | 5 | 94 |
8 | 13 | 848.40 | 20 | 13.40 | 1488 | 399 | 4.16 / 811.69 | 5 | 101 |
9 | 13 | 46.36 | 20 | 14.10 | 395 | 111 | 4.27 / 811.80 | 5 | 96 |
10 | 8 | 0.20 | 400 | 14.00 | 328 | 1837 | 6.11 / 813.63 | 5 | 103 |
Average= | 5.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.64 | 29 | 14.16 | 420 | 172 | 0.17 / 801.48 | 5 | 5 |
2 | 10 | 1055.40 | 5 | 13.81 | 1221 | 84 | 0.26 / 801.56 | 5 | 8 |
3 | 10 | 1090.40 | 3 | 13.32 | 1484 | 59 | 0.32 / 801.62 | 5 | 6 |
4 | 3 | 1098.28 | 2 | 12.76 | 1535 | 39 | 0.36 / 801.66 | 5 | 5 |
5 | 7 | 2004.20 | 40 | 7.44 | 2231 | 664 | 1.02 / 802.33 | 5 | 5 |
6 | 13 | 1972.24 | 20 | 12.66 | 2190 | 555 | 1.57 / 802.88 | 5 | 10 |
7 | 13 | 1907.16 | 20 | 13.05 | 2047 | 534 | 2.11 / 803.42 | 5 | 28 |
8 | 13 | 1821.32 | 20 | 12.89 | 2165 | 558 | 2.67 / 803.97 | 5 | 38 |
9 | 13 | 1725.08 | 20 | 12.88 | 2329 | 600 | 3.27 / 804.57 | 5 | 23 |
10 | 13 | 1218.64 | 20 | 13.35 | 1608 | 429 | 3.70 / 805.00 | 5 | 41 |
11 | 13 | 1015.76 | 20 | 13.43 | 1332 | 358 | 4.05 / 805.36 | 5 | 20 |
12 | 13 | 503.68 | 20 | 13.69 | 897 | 246 | 4.30 / 805.61 | 5 | 50 |
13 | 13 | 93.40 | 20 | 14.05 | 442 | 124 | 4.42 / 805.73 | 5 | 70 |
14 | 8 | -0.12 | 400 | 14.01 | 320 | 1793 | 6.22 / 807.52 | 5 | 99 |
Average= | 5.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.56 | 39 | 14.08 | 474 | 260 | 0.26 / 795.49 | 5 | 47 |
2 | 3 | 613.28 | -6 | 14.08 | 474 | 0 | 0.00 / 795.49 | 5 | 47 |
3 | 7 | 2005.52 | 41 | 7.25 | 2680 | 797 | 1.06 / 796.28 | 47 | 5 |
4 | 13 | 1974.76 | 20 | 12.46 | 3005 | 749 | 1.81 / 797.03 | 5 | 50 |
5 | 13 | 1896.60 | 20 | 12.64 | 2884 | 729 | 2.53 / 797.76 | 5 | 70 |
6 | 13 | 1698.12 | 20 | 12.86 | 2610 | 671 | 3.21 / 798.43 | 5 | 79 |
7 | 13 | 1183.08 | 20 | 13.16 | 1958 | 515 | 3.72 / 798.95 | 5 | 94 |
8 | 13 | 759.00 | 20 | 13.44 | 1363 | 366 | 4.09 / 799.31 | 5 | 101 |
9 | 13 | 211.68 | 20 | 13.91 | 613 | 171 | 4.26 / 799.48 | 5 | 82 |
10 | 8 | -0.04 | 400 | 13.99 | 326 | 1824 | 6.08 / 801.31 | 5 | 117 |
Average= | 5.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.52 | 27 | 14.12 | 440 | 168 | 0.17 / 789.19 | 5 | 5 |
2 | 10 | 1013.56 | 5 | 13.35 | 1282 | 86 | 0.25 / 789.27 | 5 | 7 |
3 | 10 | 1051.28 | 3 | 13.32 | 1482 | 59 | 0.31 / 789.33 | 5 | 6 |
4 | 3 | 1153.32 | 4 | 12.88 | 1569 | 81 | 0.39 / 789.41 | 5 | 8 |
5 | 7 | 2007.16 | 40 | 7.57 | 2252 | 682 | 1.08 / 790.09 | 8 | 5 |
6 | 13 | 1970.44 | 20 | 12.32 | 2989 | 736 | 1.81 / 790.83 | 5 | 44 |
7 | 13 | 1899.16 | 20 | 12.63 | 2790 | 705 | 2.52 / 791.53 | 5 | 67 |
8 | 13 | 1806.12 | 20 | 12.91 | 2422 | 625 | 3.14 / 792.16 | 5 | 43 |
9 | 13 | 1389.48 | 20 | 13.21 | 1889 | 499 | 3.64 / 792.66 | 5 | 46 |
10 | 13 | 970.28 | 20 | 13.37 | 1459 | 390 | 4.03 / 793.05 | 5 | 58 |
11 | 13 | 651.56 | 20 | 13.57 | 1057 | 287 | 4.32 / 793.34 | 5 | 52 |
12 | 13 | 26.08 | 20 | 14.14 | 358 | 101 | 4.42 / 793.44 | 5 | 68 |
13 | 8 | 0.24 | 400 | 14.02 | 319 | 1789 | 6.21 / 795.23 | 5 | 87 |
Average= | 5.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.84 | 28 | 14.09 | 489 | 193 | 0.19 / 783.17 | 5 | 43 |
2 | 3 | 935.44 | -1 | 14.09 | 489 | 0 | 0.00 / 783.17 | 5 | 43 |
3 | 7 | 2004.20 | 41 | 7.65 | 2686 | 842 | 1.04 / 784.01 | 43 | 5 |
4 | 13 | 1971.20 | 20 | 12.44 | 3007 | 748 | 1.78 / 784.76 | 5 | 47 |
5 | 13 | 1891.04 | 20 | 12.63 | 2895 | 731 | 2.51 / 785.49 | 5 | 69 |
6 | 13 | 1692.28 | 20 | 12.83 | 2637 | 677 | 3.19 / 786.16 | 5 | 79 |
7 | 13 | 1174.76 | 20 | 13.15 | 1957 | 515 | 3.71 / 786.68 | 5 | 94 |
8 | 13 | 663.72 | 20 | 13.51 | 1248 | 337 | 4.04 / 787.02 | 5 | 101 |
9 | 13 | 229.36 | 20 | 13.90 | 637 | 177 | 4.22 / 787.19 | 5 | 94 |
10 | 8 | -0.08 | 400 | 13.99 | 326 | 1824 | 6.04 / 789.02 | 5 | 84 |
Average= | 5.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.60 | 39 | 14.08 | 475 | 261 | 0.26 / 777.10 | 5 | 58 |
2 | 3 | 581.84 | -7 | 14.08 | 475 | 0 | 0.00 / 777.10 | 5 | 58 |
3 | 7 | 2004.04 | 41 | 7.35 | 2634 | 794 | 1.05 / 777.90 | 58 | 5 |
4 | 13 | 1968.56 | 20 | 12.47 | 3001 | 748 | 1.80 / 778.65 | 5 | 51 |
5 | 13 | 1889.72 | 20 | 12.66 | 2887 | 731 | 2.53 / 779.38 | 5 | 72 |
6 | 13 | 1693.96 | 20 | 12.85 | 2614 | 672 | 3.21 / 780.05 | 5 | 81 |
7 | 13 | 1273.88 | 20 | 13.12 | 2062 | 541 | 3.75 / 780.59 | 5 | 93 |
8 | 13 | 736.08 | 20 | 13.46 | 1332 | 359 | 4.11 / 780.95 | 5 | 101 |
9 | 13 | 302.60 | 20 | 13.85 | 714 | 198 | 4.30 / 781.15 | 5 | 82 |
10 | 8 | 0.16 | 400 | 14.00 | 326 | 1826 | 6.13 / 782.97 | 5 | 118 |
Average= | 5.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.12 | 27 | 14.16 | 425 | 162 | 0.16 / 770.63 | 5 | 6 |
2 | 10 | 1039.52 | 5 | 13.21 | 1432 | 95 | 0.26 / 770.73 | 5 | 10 |
3 | 10 | 1078.88 | 4 | 13.38 | 1850 | 99 | 0.36 / 770.83 | 5 | 30 |
4 | 3 | 1148.96 | 4 | 12.96 | 1939 | 101 | 0.46 / 770.93 | 5 | 33 |
5 | 7 | 2007.36 | 40 | 7.47 | 2761 | 825 | 1.28 / 771.75 | 33 | 5 |
6 | 13 | 1969.20 | 20 | 12.85 | 2439 | 627 | 1.91 / 772.38 | 5 | 9 |
7 | 13 | 1893.88 | 20 | 12.74 | 2475 | 631 | 2.54 / 773.01 | 5 | 19 |
8 | 13 | 1800.00 | 20 | 13.13 | 2121 | 557 | 3.10 / 773.57 | 5 | 14 |
9 | 13 | 1490.64 | 20 | 13.22 | 1851 | 489 | 3.59 / 774.06 | 5 | 38 |
10 | 13 | 1392.00 | 20 | 13.31 | 1627 | 433 | 4.02 / 774.49 | 5 | 29 |
11 | 13 | 852.84 | 20 | 13.49 | 1297 | 350 | 4.37 / 774.84 | 5 | 57 |
12 | 13 | 431.44 | 20 | 13.78 | 856 | 236 | 4.60 / 775.08 | 5 | 82 |
13 | 8 | 0.12 | 400 | 14.07 | 314 | 1767 | 6.37 / 776.84 | 5 | 72 |
Average= | 5.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.20 | 27 | 14.10 | 484 | 184 | 0.18 / 764.65 | 5 | 54 |
2 | 7 | 2003.52 | 40 | 7.43 | 2724 | 810 | 0.99 / 765.45 | 5 | 5 |
3 | 13 | 1968.00 | 20 | 12.45 | 2995 | 746 | 1.74 / 766.20 | 5 | 56 |
4 | 13 | 1889.48 | 20 | 12.63 | 2921 | 738 | 2.48 / 766.94 | 5 | 76 |
5 | 13 | 1685.36 | 20 | 12.83 | 2639 | 677 | 3.15 / 767.62 | 5 | 85 |
6 | 13 | 1264.12 | 20 | 13.10 | 2082 | 545 | 3.70 / 768.16 | 5 | 98 |
7 | 13 | 719.52 | 20 | 13.46 | 1345 | 362 | 4.06 / 768.52 | 5 | 109 |
8 | 13 | 19.44 | 20 | 14.14 | 367 | 104 | 4.17 / 768.63 | 5 | 106 |
9 | 8 | -0.16 | 400 | 13.98 | 330 | 1845 | 6.01 / 770.47 | 5 | 103 |
Average= | 5.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.20 | 27 | 14.06 | 499 | 189 | 0.19 / 758.81 | 5 | 66 |
2 | 7 | 2005.16 | 40 | 7.47 | 2778 | 830 | 1.02 / 759.64 | 5 | 5 |
3 | 13 | 1954.56 | 20 | 12.46 | 2992 | 746 | 1.77 / 760.38 | 5 | 65 |
4 | 13 | 1875.88 | 20 | 12.62 | 2880 | 727 | 2.49 / 761.11 | 5 | 81 |
5 | 13 | 1778.72 | 20 | 12.72 | 2752 | 700 | 3.19 / 761.81 | 5 | 87 |
6 | 13 | 1240.08 | 20 | 13.10 | 2051 | 537 | 3.73 / 762.35 | 5 | 104 |
7 | 13 | 815.52 | 20 | 13.40 | 1471 | 394 | 4.12 / 762.74 | 5 | 113 |
8 | 13 | 40.04 | 20 | 14.11 | 398 | 112 | 4.24 / 762.86 | 5 | 110 |
9 | 8 | 0.28 | 348 | 13.98 | 330 | 1605 | 5.84 / 764.46 | 5 | 133 |
Average= | 5.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.64 | 27 | 14.07 | 498 | 189 | 0.19 / 753.16 | 5 | 68 |
2 | 7 | 2012.00 | 41 | 7.63 | 2843 | 889 | 1.08 / 754.05 | 5 | 7 |
3 | 13 | 1972.40 | 20 | 12.44 | 3015 | 750 | 1.83 / 754.80 | 5 | 68 |
4 | 13 | 1893.72 | 20 | 12.61 | 2912 | 734 | 2.56 / 755.54 | 5 | 84 |
5 | 13 | 1592.36 | 20 | 12.90 | 2512 | 648 | 3.21 / 756.19 | 5 | 95 |
6 | 13 | 1056.00 | 20 | 13.22 | 1811 | 479 | 3.69 / 756.67 | 5 | 110 |
7 | 13 | 630.12 | 20 | 13.52 | 1217 | 329 | 4.02 / 756.99 | 5 | 119 |
8 | 13 | 44.08 | 20 | 14.09 | 408 | 115 | 4.13 / 757.11 | 5 | 116 |
9 | 8 | -0.08 | 323 | 13.95 | 335 | 1509 | 5.64 / 758.62 | 5 | 130 |
Average= | 5.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.36 | 26 | 14.10 | 494 | 181 | 0.18 / 747.53 | 5 | 58 |
2 | 3 | 1020.72 | 1 | 12.39 | 1751 | 22 | 0.20 / 747.55 | 5 | 5 |
3 | 7 | 2010.44 | 40 | 7.78 | 2821 | 878 | 1.08 / 748.43 | 5 | 8 |
4 | 13 | 1961.32 | 20 | 12.51 | 2984 | 747 | 1.83 / 749.17 | 5 | 70 |
5 | 13 | 1877.76 | 20 | 12.65 | 2876 | 728 | 2.55 / 749.90 | 5 | 84 |
6 | 13 | 1577.20 | 20 | 12.89 | 2491 | 642 | 3.20 / 750.54 | 5 | 96 |
7 | 13 | 965.20 | 20 | 13.28 | 1676 | 445 | 3.64 / 750.99 | 5 | 112 |
8 | 13 | 455.28 | 20 | 13.70 | 928 | 254 | 3.90 / 751.24 | 5 | 104 |
9 | 13 | 15.20 | 20 | 14.13 | 366 | 103 | 4.00 / 751.35 | 5 | 111 |
10 | 8 | -0.12 | 351 | 13.94 | 333 | 1629 | 5.63 / 752.98 | 5 | 134 |
Average= | 5.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.84 | 28 | 14.08 | 492 | 194 | 0.19 / 741.64 | 5 | 72 |
2 | 3 | 955.76 | -1 | 14.08 | 492 | 0 | 0.00 / 741.64 | 5 | 72 |
3 | 7 | 2006.32 | 40 | 7.75 | 2816 | 873 | 1.07 / 742.52 | 72 | 10 |
4 | 13 | 1956.92 | 20 | 12.45 | 2999 | 747 | 1.81 / 743.26 | 5 | 72 |
5 | 13 | 1876.08 | 20 | 12.63 | 2893 | 731 | 2.54 / 743.99 | 5 | 85 |
6 | 13 | 1670.68 | 20 | 12.82 | 2616 | 671 | 3.22 / 744.67 | 5 | 93 |
7 | 13 | 1144.04 | 20 | 13.16 | 1924 | 506 | 3.72 / 745.17 | 5 | 109 |
8 | 13 | 603.04 | 20 | 13.55 | 1179 | 320 | 4.04 / 745.49 | 5 | 118 |
9 | 8 | 0.16 | 400 | 13.97 | 332 | 1855 | 5.90 / 747.35 | 5 | 118 |
Average= | 5.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.32 | 28 | 14.09 | 498 | 196 | 0.20 / 735.93 | 5 | 70 |
2 | 7 | 2006.76 | 41 | 7.91 | 2853 | 925 | 1.12 / 736.86 | 70 | 15 |
3 | 13 | 1951.84 | 20 | 12.48 | 2986 | 745 | 1.87 / 737.60 | 5 | 74 |
4 | 13 | 1862.76 | 20 | 12.64 | 2871 | 726 | 2.59 / 738.33 | 5 | 86 |
5 | 13 | 1554.68 | 20 | 12.90 | 2467 | 636 | 3.23 / 738.97 | 5 | 98 |
6 | 13 | 1133.24 | 20 | 13.17 | 1913 | 504 | 3.73 / 739.47 | 5 | 110 |
7 | 13 | 489.28 | 20 | 13.64 | 1024 | 279 | 4.01 / 739.75 | 5 | 118 |
8 | 8 | 0.20 | 367 | 13.96 | 332 | 1701 | 5.71 / 741.45 | 5 | 133 |
Average= | 5.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.48 | 28 | 14.06 | 507 | 200 | 0.20 / 730.12 | 5 | 72 |
2 | 7 | 2008.24 | 40 | 7.88 | 2876 | 907 | 1.11 / 731.03 | 72 | 17 |
3 | 13 | 1956.28 | 20 | 12.46 | 2986 | 744 | 1.85 / 731.77 | 5 | 74 |
4 | 13 | 1879.40 | 20 | 12.61 | 2885 | 728 | 2.58 / 732.50 | 5 | 86 |
5 | 13 | 1577.84 | 20 | 12.89 | 2502 | 645 | 3.22 / 733.14 | 5 | 98 |
6 | 13 | 1144.08 | 20 | 13.16 | 1937 | 510 | 3.73 / 733.65 | 5 | 112 |
7 | 13 | 602.20 | 20 | 13.54 | 1182 | 320 | 4.05 / 733.97 | 5 | 120 |
8 | 8 | 0.20 | 379 | 13.93 | 334 | 1763 | 5.82 / 735.74 | 5 | 129 |
Average= | 5.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.12 | 27 | 14.06 | 506 | 192 | 0.19 / 724.50 | 5 | 83 |
2 | 3 | 1033.28 | 1 | 12.54 | 1778 | 22 | 0.21 / 724.52 | 5 | 10 |
3 | 7 | 2010.20 | 40 | 8.02 | 2972 | 953 | 1.17 / 725.47 | 10 | 24 |
4 | 13 | 1961.40 | 20 | 12.46 | 3009 | 750 | 1.92 / 726.22 | 5 | 77 |
5 | 13 | 1880.00 | 20 | 12.62 | 2889 | 729 | 2.65 / 726.95 | 5 | 86 |
6 | 13 | 1675.20 | 20 | 12.82 | 2631 | 675 | 3.32 / 727.63 | 5 | 96 |
7 | 13 | 1247.88 | 20 | 13.11 | 2074 | 544 | 3.87 / 728.17 | 5 | 109 |
8 | 13 | 493.20 | 20 | 13.62 | 1035 | 282 | 4.15 / 728.45 | 5 | 121 |
9 | 8 | -0.04 | 313 | 13.96 | 336 | 1468 | 5.62 / 729.92 | 5 | 130 |
Average= | 5.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.16 | 27 | 14.06 | 499 | 189 | 0.19 / 719.48 | 5 | 75 |
2 | 7 | 2003.04 | 40 | 8.42 | 2897 | 976 | 1.17 / 720.46 | 75 | 25 |
3 | 13 | 1945.12 | 20 | 12.48 | 2977 | 743 | 1.91 / 721.20 | 5 | 77 |
4 | 13 | 1854.60 | 20 | 12.63 | 2867 | 724 | 2.63 / 721.93 | 5 | 87 |
5 | 13 | 1555.48 | 20 | 12.89 | 2480 | 639 | 3.27 / 722.56 | 5 | 99 |
6 | 13 | 1125.92 | 20 | 13.17 | 1898 | 500 | 3.77 / 723.06 | 5 | 111 |
7 | 13 | 474.20 | 20 | 13.64 | 1010 | 276 | 4.05 / 723.34 | 5 | 120 |
8 | 8 | 0.32 | 171 | 14.01 | 345 | 827 | 4.87 / 724.17 | 5 | 137 |
9 | 14 | 0.04 | 29 | 13.88 | 345 | 139 | 5.01 / 724.31 | 8 | 115 |
Average= | 5.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.56 | 27 | 14.06 | 502 | 191 | 0.19 / 713.78 | 5 | 77 |
2 | 7 | 2005.92 | 40 | 8.73 | 2921 | 1020 | 1.21 / 714.80 | 5 | 30 |
3 | 13 | 1938.64 | 20 | 12.50 | 2958 | 739 | 1.95 / 715.54 | 5 | 79 |
4 | 13 | 1845.96 | 20 | 12.66 | 2823 | 715 | 2.66 / 716.26 | 5 | 87 |
5 | 13 | 1427.04 | 20 | 12.96 | 2318 | 601 | 3.27 / 716.86 | 5 | 103 |
6 | 13 | 999.32 | 20 | 13.24 | 1741 | 461 | 3.73 / 717.32 | 5 | 115 |
7 | 13 | 460.92 | 20 | 13.65 | 996 | 272 | 4.00 / 717.59 | 5 | 121 |
8 | 13 | 123.12 | 20 | 14.01 | 527 | 148 | 4.15 / 717.74 | 5 | 120 |
9 | 8 | 0.12 | 329 | 13.95 | 339 | 1556 | 5.70 / 719.29 | 5 | 132 |
Average= | 5.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.00 | 28 | 14.05 | 513 | 202 | 0.20 / 708.09 | 5 | 76 |
2 | 3 | 965.52 | -1 | 14.05 | 513 | 0 | 0.00 / 708.09 | 5 | 76 |
3 | 7 | 2004.44 | 40 | 8.76 | 2938 | 1029 | 1.23 / 709.12 | 76 | 33 |
4 | 13 | 1949.24 | 20 | 12.48 | 2992 | 747 | 1.98 / 709.87 | 5 | 81 |
5 | 13 | 1864.92 | 20 | 12.63 | 2871 | 725 | 2.70 / 710.59 | 5 | 89 |
6 | 13 | 1457.20 | 20 | 12.95 | 2344 | 607 | 3.31 / 711.20 | 5 | 102 |
7 | 13 | 1018.80 | 20 | 13.24 | 1761 | 466 | 3.78 / 711.67 | 5 | 116 |
8 | 13 | 382.44 | 20 | 13.72 | 883 | 242 | 4.02 / 711.91 | 5 | 123 |
9 | 8 | 0.16 | 355 | 13.92 | 340 | 1680 | 5.70 / 713.59 | 5 | 135 |
Average= | 5.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.96 | 28 | 14.05 | 511 | 201 | 0.20 / 702.54 | 5 | 77 |
2 | 7 | 2007.04 | 41 | 8.83 | 2974 | 1077 | 1.28 / 703.62 | 77 | 34 |
3 | 13 | 1942.56 | 20 | 12.49 | 2984 | 745 | 2.02 / 704.36 | 5 | 81 |
4 | 13 | 1848.16 | 20 | 12.64 | 2862 | 724 | 2.75 / 705.08 | 5 | 90 |
5 | 13 | 1424.52 | 20 | 12.96 | 2315 | 600 | 3.35 / 705.68 | 5 | 104 |
6 | 13 | 999.24 | 20 | 13.23 | 1745 | 462 | 3.81 / 706.15 | 5 | 116 |
7 | 13 | 446.68 | 20 | 13.68 | 961 | 263 | 4.07 / 706.41 | 5 | 122 |
8 | 8 | 0.28 | 313 | 13.93 | 340 | 1482 | 5.55 / 707.89 | 5 | 130 |
Average= | 5.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.04 | 28 | 14.03 | 523 | 205 | 0.21 / 696.95 | 5 | 79 |
2 | 7 | 2010.88 | 40 | 8.84 | 2953 | 1044 | 1.25 / 697.99 | 79 | 35 |
3 | 13 | 1953.80 | 20 | 12.47 | 2987 | 745 | 1.99 / 698.74 | 5 | 82 |
4 | 13 | 1860.24 | 20 | 12.64 | 2860 | 723 | 2.72 / 699.46 | 5 | 89 |
5 | 13 | 1540.00 | 20 | 12.90 | 2445 | 631 | 3.35 / 700.09 | 5 | 102 |
6 | 13 | 1000.28 | 20 | 13.25 | 1732 | 459 | 3.81 / 700.55 | 5 | 116 |
7 | 13 | 464.64 | 20 | 13.65 | 992 | 271 | 4.08 / 700.82 | 5 | 124 |
8 | 8 | 0.08 | 320 | 13.91 | 341 | 1518 | 5.60 / 702.34 | 5 | 131 |
Average= | 5.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.88 | 30 | 14.06 | 511 | 216 | 0.22 / 691.42 | 5 | 79 |
2 | 3 | 964.32 | -1 | 14.06 | 511 | 0 | 0.00 / 691.42 | 5 | 79 |
3 | 7 | 2008.00 | 40 | 9.03 | 2973 | 1074 | 1.29 / 692.50 | 79 | 37 |
4 | 13 | 1947.60 | 20 | 12.48 | 2993 | 747 | 2.04 / 693.24 | 5 | 82 |
5 | 13 | 1860.08 | 20 | 12.63 | 2857 | 722 | 2.76 / 693.97 | 5 | 90 |
6 | 13 | 1450.20 | 20 | 12.93 | 2342 | 606 | 3.36 / 694.57 | 5 | 103 |
7 | 13 | 1015.72 | 20 | 13.23 | 1763 | 466 | 3.83 / 695.04 | 5 | 117 |
8 | 13 | 685.68 | 20 | 13.46 | 1311 | 353 | 4.18 / 695.39 | 5 | 125 |
9 | 8 | 0.00 | 282 | 13.93 | 344 | 1351 | 5.53 / 696.74 | 5 | 135 |
Average= | 5.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.00 | 30 | 14.01 | 506 | 213 | 0.21 / 686.07 | 5 | 86 |
2 | 7 | 2003.16 | 41 | 9.18 | 2940 | 1107 | 1.32 / 687.18 | 86 | 39 |
3 | 13 | 1941.36 | 20 | 12.49 | 2984 | 745 | 2.06 / 687.92 | 5 | 82 |
4 | 13 | 1847.72 | 20 | 12.63 | 2855 | 721 | 2.79 / 688.64 | 5 | 89 |
5 | 13 | 1526.32 | 20 | 12.91 | 2446 | 632 | 3.42 / 689.27 | 5 | 101 |
6 | 13 | 984.56 | 20 | 13.25 | 1723 | 457 | 3.87 / 689.73 | 5 | 117 |
7 | 13 | 443.16 | 20 | 13.67 | 967 | 264 | 4.14 / 690.00 | 5 | 122 |
8 | 13 | 56.44 | 20 | 14.09 | 433 | 122 | 4.26 / 690.12 | 5 | 118 |
9 | 13 | 35.16 | 20 | 14.07 | 403 | 113 | 4.37 / 690.23 | 5 | 116 |
10 | 8 | 0.00 | 25 | 14.15 | 355 | 126 | 4.50 / 690.36 | 5 | 132 |
11 | 14 | 0.04 | 175 | 13.96 | 348 | 850 | 5.35 / 691.21 | 6 | 114 |
Average= | 5.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.20 | 30 | 14.02 | 509 | 214 | 0.21 / 680.56 | 5 | 83 |
2 | 7 | 2004.32 | 41 | 9.46 | 2969 | 1152 | 1.37 / 681.71 | 83 | 42 |
3 | 13 | 1940.48 | 20 | 12.52 | 2973 | 744 | 2.11 / 682.45 | 5 | 82 |
4 | 13 | 1855.36 | 20 | 12.63 | 2865 | 724 | 2.83 / 683.18 | 5 | 90 |
5 | 13 | 1343.64 | 20 | 13.01 | 2197 | 572 | 3.41 / 683.75 | 5 | 106 |
6 | 13 | 1246.20 | 20 | 13.08 | 2060 | 539 | 3.94 / 684.29 | 5 | 111 |
7 | 13 | 444.84 | 20 | 13.66 | 967 | 264 | 4.21 / 684.55 | 5 | 123 |
8 | 13 | 73.44 | 20 | 14.05 | 456 | 128 | 4.34 / 684.68 | 5 | 120 |
9 | 13 | 40.88 | 20 | 14.05 | 411 | 115 | 4.45 / 684.79 | 5 | 116 |
10 | 13 | 6.36 | 20 | 14.08 | 363 | 102 | 4.55 / 684.90 | 5 | 100 |
11 | 8 | -0.12 | 113 | 14.00 | 348 | 551 | 5.10 / 685.45 | 5 | 129 |
12 | 14 | 0.04 | 87 | 13.86 | 341 | 411 | 5.52 / 685.86 | 12 | 119 |
Average= | 5.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.28 | 30 | 14.03 | 497 | 209 | 0.21 / 675.10 | 5 | 93 |
2 | 7 | 2004.84 | 40 | 9.67 | 2985 | 1155 | 1.36 / 676.25 | 5 | 45 |
3 | 13 | 1942.92 | 20 | 12.53 | 2964 | 743 | 2.11 / 676.99 | 5 | 83 |
4 | 13 | 1852.16 | 20 | 12.66 | 2837 | 718 | 2.82 / 677.71 | 5 | 89 |
5 | 13 | 1538.60 | 20 | 12.90 | 2441 | 630 | 3.45 / 678.34 | 5 | 101 |
6 | 13 | 1101.08 | 20 | 13.19 | 1877 | 495 | 3.95 / 678.84 | 5 | 116 |
7 | 13 | 424.28 | 20 | 13.69 | 943 | 258 | 4.21 / 679.09 | 5 | 123 |
8 | 13 | 128.08 | 20 | 13.99 | 535 | 150 | 4.36 / 679.24 | 5 | 121 |
9 | 8 | 0.12 | 228 | 13.95 | 345 | 1097 | 5.46 / 680.34 | 5 | 129 |
Average= | 5.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.48 | 30 | 14.02 | 513 | 216 | 0.22 / 670.06 | 5 | 84 |
2 | 7 | 2003.20 | 40 | 9.65 | 2991 | 1155 | 1.37 / 671.22 | 84 | 45 |
3 | 13 | 1935.76 | 20 | 12.51 | 2955 | 739 | 2.11 / 671.96 | 5 | 83 |
4 | 13 | 1846.28 | 20 | 12.64 | 2854 | 721 | 2.83 / 672.68 | 5 | 90 |
5 | 13 | 1427.16 | 20 | 12.97 | 2307 | 598 | 3.43 / 673.28 | 5 | 104 |
6 | 13 | 1000.16 | 20 | 13.24 | 1730 | 458 | 3.89 / 673.73 | 5 | 118 |
7 | 13 | 257.08 | 20 | 13.84 | 714 | 198 | 4.09 / 673.93 | 5 | 127 |
8 | 8 | -0.12 | 150 | 14.00 | 343 | 720 | 4.81 / 674.65 | 5 | 130 |
9 | 14 | -0.16 | 50 | 13.85 | 338 | 234 | 5.04 / 674.89 | 14 | 121 |
Average= | 5.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.76 | 30 | 14.02 | 504 | 212 | 0.21 / 664.70 | 5 | 85 |
2 | 7 | 2010.16 | 41 | 9.78 | 2993 | 1200 | 1.41 / 665.90 | 85 | 46 |
3 | 13 | 1939.40 | 20 | 12.51 | 2960 | 741 | 2.15 / 666.64 | 5 | 84 |
4 | 13 | 1745.12 | 20 | 12.73 | 2709 | 690 | 2.84 / 667.33 | 5 | 93 |
5 | 13 | 1340.04 | 20 | 13.01 | 2183 | 568 | 3.41 / 667.90 | 5 | 107 |
6 | 13 | 902.60 | 20 | 13.31 | 1600 | 426 | 3.84 / 668.33 | 5 | 120 |
7 | 13 | 348.72 | 20 | 13.75 | 837 | 230 | 4.07 / 668.56 | 5 | 125 |
8 | 8 | 0.16 | 270 | 13.91 | 343 | 1288 | 5.35 / 669.85 | 5 | 129 |
Average= | 5.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.20 | 29 | 14.03 | 501 | 204 | 0.20 / 659.39 | 5 | 91 |
2 | 3 | 1046.12 | 1 | 12.61 | 1812 | 23 | 0.23 / 659.41 | 5 | 27 |
3 | 7 | 2004.32 | 41 | 10.05 | 2998 | 1235 | 1.46 / 660.65 | 27 | 49 |
4 | 13 | 1934.08 | 20 | 12.54 | 2957 | 742 | 2.20 / 661.39 | 5 | 85 |
5 | 13 | 1838.96 | 20 | 12.66 | 2828 | 716 | 2.92 / 662.10 | 5 | 90 |
6 | 13 | 1305.80 | 20 | 13.03 | 2128 | 555 | 3.47 / 662.66 | 5 | 107 |
7 | 13 | 884.84 | 20 | 13.32 | 1571 | 419 | 3.89 / 663.08 | 5 | 119 |
8 | 13 | 248.52 | 20 | 13.85 | 692 | 192 | 4.08 / 663.27 | 5 | 122 |
9 | 13 | 28.28 | 20 | 14.10 | 387 | 109 | 4.19 / 663.38 | 5 | 117 |
10 | 8 | 0.40 | 235 | 13.92 | 341 | 1115 | 5.31 / 664.49 | 5 | 133 |
Average= | 5.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.44 | 30 | 14.01 | 516 | 217 | 0.22 / 654.37 | 5 | 83 |
2 | 3 | 943.92 | -1 | 14.01 | 516 | 0 | 0.00 / 654.37 | 5 | 83 |
3 | 7 | 2006.92 | 40 | 9.99 | 3005 | 1201 | 1.42 / 655.57 | 83 | 48 |
4 | 13 | 1935.00 | 20 | 12.49 | 2956 | 738 | 2.16 / 656.30 | 5 | 83 |
5 | 13 | 1843.76 | 20 | 12.66 | 2828 | 716 | 2.87 / 657.02 | 5 | 90 |
6 | 13 | 1415.36 | 20 | 12.98 | 2287 | 594 | 3.47 / 657.61 | 5 | 105 |
7 | 13 | 881.00 | 20 | 13.32 | 1577 | 420 | 3.89 / 658.03 | 5 | 121 |
8 | 13 | 241.48 | 20 | 13.86 | 688 | 191 | 4.08 / 658.23 | 5 | 127 |
9 | 8 | -0.12 | 6 | 14.08 | 349 | 29 | 4.11 / 658.25 | 5 | 130 |
10 | 14 | -0.16 | 194 | 13.95 | 343 | 928 | 5.03 / 659.18 | 5 | 116 |
Average= | 5.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.64 | 30 | 14.03 | 499 | 210 | 0.21 / 648.94 | 5 | 92 |
2 | 7 | 2008.92 | 41 | 10.04 | 3010 | 1239 | 1.45 / 650.18 | 92 | 50 |
3 | 13 | 1930.64 | 20 | 12.51 | 2956 | 740 | 2.19 / 650.92 | 5 | 85 |
4 | 13 | 1729.56 | 20 | 12.74 | 2698 | 687 | 2.88 / 651.60 | 5 | 94 |
5 | 13 | 1331.60 | 20 | 13.02 | 2180 | 568 | 3.44 / 652.17 | 5 | 108 |
6 | 13 | 1008.44 | 20 | 13.24 | 1746 | 462 | 3.91 / 652.63 | 5 | 118 |
7 | 13 | 334.52 | 20 | 13.77 | 812 | 224 | 4.13 / 652.86 | 5 | 122 |
8 | 13 | 27.36 | 20 | 14.09 | 389 | 110 | 4.24 / 652.97 | 5 | 119 |
9 | 8 | 0.04 | 247 | 13.90 | 344 | 1181 | 5.42 / 654.15 | 6 | 132 |
Average= | 5.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.80 | 30 | 14.04 | 505 | 213 | 0.21 / 643.93 | 5 | 91 |
2 | 7 | 2002.76 | 40 | 10.23 | 3012 | 1233 | 1.45 / 645.17 | 5 | 53 |
3 | 13 | 1929.44 | 20 | 12.52 | 2962 | 742 | 2.19 / 645.91 | 5 | 85 |
4 | 13 | 1736.16 | 20 | 12.78 | 2696 | 689 | 2.88 / 646.60 | 5 | 94 |
5 | 13 | 1306.36 | 20 | 13.03 | 2149 | 560 | 3.44 / 647.16 | 5 | 109 |
6 | 13 | 871.08 | 20 | 13.34 | 1567 | 418 | 3.85 / 647.58 | 5 | 122 |
7 | 13 | 219.76 | 20 | 13.88 | 666 | 185 | 4.04 / 647.76 | 5 | 127 |
8 | 8 | -0.20 | 189 | 13.96 | 347 | 916 | 4.95 / 648.68 | 5 | 134 |
9 | 14 | -0.12 | 11 | 13.82 | 346 | 53 | 5.01 / 648.73 | 6 | 125 |
Average= | 5.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.60 | 27 | 14.05 | 505 | 192 | 0.19 / 638.91 | 5 | 86 |
2 | 10 | 1037.24 | 3 | 13.20 | 1816 | 72 | 0.26 / 638.98 | 5 | 69 |
3 | 3 | 1019.48 | 1 | 12.30 | 1789 | 22 | 0.29 / 639.01 | 5 | 5 |
4 | 7 | 2005.44 | 40 | 10.27 | 3023 | 1242 | 1.53 / 640.25 | 5 | 53 |
5 | 13 | 1931.64 | 20 | 12.52 | 2964 | 742 | 2.27 / 640.99 | 5 | 85 |
6 | 13 | 1736.68 | 20 | 12.77 | 2703 | 690 | 2.96 / 641.68 | 5 | 94 |
7 | 13 | 1323.20 | 20 | 13.03 | 2173 | 566 | 3.53 / 642.25 | 5 | 108 |
8 | 13 | 792.12 | 20 | 13.39 | 1451 | 389 | 3.91 / 642.64 | 5 | 122 |
9 | 13 | 74.92 | 20 | 14.04 | 455 | 128 | 4.04 / 642.76 | 5 | 120 |
10 | 8 | 0.40 | 194 | 13.96 | 343 | 929 | 4.97 / 643.69 | 5 | 137 |
11 | 14 | 0.40 | 6 | 13.83 | 348 | 29 | 5.00 / 643.72 | 7 | 116 |
Average= | 5.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.40 | 28 | 14.03 | 498 | 196 | 0.20 / 633.75 | 5 | 83 |
2 | 3 | 967.84 | -1 | 14.03 | 498 | 0 | 0.00 / 633.75 | 5 | 83 |
3 | 7 | 2009.72 | 40 | 10.29 | 3033 | 1248 | 1.44 / 635.00 | 83 | 51 |
4 | 13 | 1933.40 | 20 | 12.51 | 2947 | 737 | 2.18 / 635.74 | 5 | 84 |
5 | 13 | 1739.48 | 20 | 12.76 | 2705 | 690 | 2.87 / 636.43 | 5 | 93 |
6 | 13 | 1528.92 | 20 | 12.92 | 2440 | 630 | 3.50 / 637.06 | 5 | 102 |
7 | 13 | 775.92 | 20 | 13.40 | 1429 | 383 | 3.89 / 637.44 | 5 | 121 |
8 | 13 | 454.36 | 20 | 13.66 | 978 | 267 | 4.15 / 637.71 | 5 | 124 |
9 | 8 | 0.08 | 213 | 13.94 | 341 | 1013 | 5.16 / 638.72 | 5 | 129 |
Average= | 5.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.20 | 28 | 14.03 | 496 | 195 | 0.19 / 628.17 | 5 | 80 |
2 | 3 | 1019.96 | 1 | 11.49 | 1781 | 20 | 0.22 / 628.19 | 5 | 5 |
3 | 7 | 2004.04 | 41 | 10.37 | 3039 | 1292 | 1.51 / 629.48 | 5 | 53 |
4 | 13 | 1930.92 | 20 | 12.53 | 2958 | 741 | 2.25 / 630.23 | 5 | 85 |
5 | 13 | 1737.00 | 20 | 12.75 | 2709 | 691 | 2.94 / 630.92 | 5 | 93 |
6 | 13 | 1322.52 | 20 | 13.05 | 2167 | 566 | 3.51 / 631.48 | 5 | 108 |
7 | 13 | 805.04 | 20 | 13.38 | 1475 | 395 | 3.90 / 631.88 | 5 | 121 |
8 | 13 | 174.76 | 20 | 13.93 | 589 | 164 | 4.06 / 632.04 | 5 | 124 |
9 | 8 | 0.00 | 320 | 13.88 | 341 | 1515 | 5.58 / 633.56 | 5 | 134 |
Average= | 5.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.64 | 29 | 14.02 | 498 | 202 | 0.20 / 622.71 | 5 | 83 |
2 | 3 | 954.56 | -1 | 14.02 | 498 | 0 | 0.00 / 622.71 | 5 | 83 |
3 | 7 | 2004.00 | 41 | 10.40 | 3026 | 1290 | 1.49 / 624.00 | 83 | 54 |
4 | 13 | 1935.44 | 20 | 12.51 | 2968 | 743 | 2.24 / 624.75 | 5 | 85 |
5 | 13 | 1640.04 | 20 | 12.82 | 2572 | 659 | 2.89 / 625.40 | 5 | 97 |
6 | 13 | 1325.72 | 20 | 13.03 | 2175 | 567 | 3.46 / 625.97 | 5 | 108 |
7 | 13 | 786.56 | 20 | 13.41 | 1444 | 387 | 3.85 / 626.36 | 5 | 122 |
8 | 13 | 346.48 | 20 | 13.76 | 826 | 227 | 4.08 / 626.59 | 5 | 122 |
9 | 8 | 0.08 | 294 | 13.88 | 341 | 1392 | 5.47 / 627.98 | 5 | 130 |
Average= | 5.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.32 | 29 | 14.02 | 510 | 207 | 0.21 / 616.95 | 5 | 81 |
2 | 7 | 2004.84 | 41 | 10.40 | 3049 | 1300 | 1.51 / 618.25 | 81 | 54 |
3 | 13 | 1931.84 | 20 | 12.51 | 2968 | 743 | 2.25 / 619.00 | 5 | 85 |
4 | 13 | 1841.28 | 20 | 12.67 | 2852 | 723 | 2.97 / 619.72 | 5 | 90 |
5 | 13 | 1397.72 | 20 | 13.02 | 2256 | 587 | 3.56 / 620.31 | 5 | 106 |
6 | 13 | 862.16 | 20 | 13.35 | 1554 | 415 | 3.98 / 620.72 | 5 | 121 |
7 | 13 | 203.80 | 20 | 13.90 | 634 | 176 | 4.15 / 620.90 | 5 | 123 |
8 | 8 | 0.16 | 344 | 13.86 | 338 | 1612 | 5.76 / 622.51 | 5 | 137 |
Average= | 5.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.96 | 28 | 14.04 | 493 | 194 | 0.19 / 611.29 | 5 | 92 |
2 | 3 | 1069.16 | 2 | 12.91 | 1867 | 48 | 0.24 / 611.34 | 5 | 50 |
3 | 7 | 2008.36 | 40 | 10.66 | 3025 | 1290 | 1.53 / 612.63 | 50 | 58 |
4 | 13 | 1943.24 | 20 | 12.51 | 2973 | 744 | 2.28 / 613.37 | 5 | 86 |
5 | 13 | 1851.88 | 20 | 12.66 | 2863 | 725 | 3.00 / 614.09 | 5 | 91 |
6 | 13 | 1226.40 | 20 | 13.10 | 2043 | 535 | 3.54 / 614.63 | 5 | 111 |
7 | 13 | 705.80 | 20 | 13.46 | 1328 | 357 | 3.89 / 614.99 | 5 | 123 |
8 | 13 | 181.64 | 20 | 13.92 | 606 | 169 | 4.06 / 615.16 | 5 | 123 |
9 | 8 | 0.20 | 336 | 13.85 | 342 | 1592 | 5.65 / 616.75 | 5 | 129 |
Average= | 5.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.08 | 29 | 14.02 | 498 | 202 | 0.20 / 606.25 | 5 | 81 |
2 | 3 | 961.36 | -1 | 14.02 | 498 | 0 | 0.00 / 606.25 | 5 | 81 |
3 | 7 | 2009.88 | 40 | 10.65 | 3023 | 1288 | 1.49 / 607.53 | 81 | 57 |
4 | 13 | 1934.04 | 20 | 12.51 | 2968 | 743 | 2.23 / 608.28 | 5 | 86 |
5 | 13 | 1835.72 | 20 | 12.66 | 2839 | 719 | 2.95 / 608.99 | 5 | 91 |
6 | 13 | 1305.88 | 20 | 13.05 | 2144 | 560 | 3.51 / 609.55 | 5 | 109 |
7 | 13 | 882.52 | 20 | 13.34 | 1584 | 423 | 3.93 / 609.98 | 5 | 122 |
8 | 13 | 124.44 | 20 | 13.97 | 532 | 149 | 4.08 / 610.13 | 5 | 123 |
9 | 8 | 0.04 | 165 | 13.97 | 348 | 802 | 4.88 / 610.93 | 5 | 134 |
10 | 14 | -0.04 | 35 | 13.80 | 343 | 166 | 5.05 / 611.09 | 11 | 120 |
Average= | 5.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.28 | 28 | 14.03 | 506 | 199 | 0.20 / 600.94 | 5 | 93 |
2 | 3 | 1032.44 | 1 | 12.58 | 1792 | 23 | 0.22 / 600.96 | 5 | 13 |
3 | 7 | 2004.52 | 40 | 10.75 | 3021 | 1299 | 1.52 / 602.26 | 13 | 59 |
4 | 13 | 1931.56 | 20 | 12.54 | 2958 | 742 | 2.26 / 603.00 | 5 | 86 |
5 | 13 | 1736.60 | 20 | 12.76 | 2708 | 691 | 2.95 / 603.70 | 5 | 95 |
6 | 13 | 1316.08 | 20 | 13.04 | 2171 | 566 | 3.52 / 604.26 | 5 | 109 |
7 | 13 | 793.56 | 20 | 13.39 | 1462 | 392 | 3.91 / 604.65 | 5 | 123 |
8 | 13 | 31.44 | 20 | 14.08 | 392 | 110 | 4.02 / 604.76 | 5 | 118 |
9 | 8 | 0.08 | 269 | 13.86 | 343 | 1279 | 5.30 / 606.04 | 5 | 129 |
Average= | 5.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.48 | 28 | 14.05 | 490 | 193 | 0.19 / 595.95 | 5 | 90 |
2 | 3 | 1035.24 | 1 | 12.47 | 1818 | 23 | 0.22 / 595.97 | 5 | 11 |
3 | 7 | 2008.52 | 40 | 10.76 | 3024 | 1302 | 1.52 / 597.27 | 11 | 59 |
4 | 13 | 1929.04 | 20 | 12.51 | 2954 | 739 | 2.26 / 598.01 | 5 | 87 |
5 | 13 | 1727.48 | 20 | 12.78 | 2694 | 689 | 2.94 / 598.70 | 5 | 95 |
6 | 13 | 1299.16 | 20 | 13.06 | 2136 | 558 | 3.50 / 599.26 | 5 | 109 |
7 | 13 | 763.08 | 20 | 13.41 | 1421 | 381 | 3.88 / 599.64 | 5 | 124 |
8 | 13 | 123.12 | 20 | 13.97 | 515 | 144 | 4.03 / 599.78 | 5 | 110 |
9 | 8 | 0.28 | 176 | 13.94 | 346 | 849 | 4.88 / 600.63 | 5 | 132 |
10 | 14 | 0.12 | 24 | 13.77 | 343 | 113 | 4.99 / 600.74 | 7 | 122 |
Average= | 5.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.56 | 29 | 14.05 | 508 | 207 | 0.21 / 590.95 | 5 | 84 |
2 | 3 | 964.56 | -1 | 14.05 | 508 | 0 | 0.00 / 590.95 | 5 | 84 |
3 | 7 | 2009.20 | 40 | 10.75 | 3027 | 1302 | 1.51 / 592.25 | 84 | 58 |
4 | 13 | 1935.44 | 20 | 12.50 | 2974 | 743 | 2.25 / 592.99 | 5 | 85 |
5 | 13 | 1837.28 | 20 | 12.67 | 2834 | 718 | 2.97 / 593.71 | 5 | 91 |
6 | 13 | 1292.92 | 20 | 13.08 | 2130 | 557 | 3.53 / 594.27 | 5 | 110 |
7 | 13 | 756.48 | 20 | 13.42 | 1409 | 378 | 3.91 / 594.65 | 5 | 123 |
8 | 13 | 111.20 | 20 | 13.98 | 507 | 142 | 4.05 / 594.79 | 5 | 122 |
9 | 8 | -0.16 | 125 | 13.99 | 348 | 609 | 4.66 / 595.40 | 5 | 132 |
10 | 14 | -0.12 | 75 | 13.79 | 343 | 355 | 5.01 / 595.75 | 13 | 127 |
Average= | 5.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.92 | 28 | 14.02 | 513 | 201 | 0.20 / 585.66 | 5 | 92 |
2 | 3 | 1063.88 | 2 | 12.85 | 1863 | 48 | 0.25 / 585.71 | 5 | 44 |
3 | 7 | 2003.84 | 40 | 10.85 | 3012 | 1307 | 1.56 / 587.01 | 44 | 60 |
4 | 13 | 1933.76 | 20 | 12.52 | 2958 | 741 | 2.30 / 587.75 | 5 | 85 |
5 | 13 | 1837.40 | 20 | 12.67 | 2846 | 721 | 3.02 / 588.48 | 5 | 91 |
6 | 13 | 1295.00 | 20 | 13.06 | 2134 | 557 | 3.58 / 589.03 | 5 | 109 |
7 | 13 | 772.16 | 20 | 13.41 | 1428 | 383 | 3.96 / 589.42 | 5 | 121 |
8 | 13 | 141.88 | 20 | 13.95 | 557 | 155 | 4.11 / 589.57 | 5 | 122 |
9 | 8 | 0.00 | 243 | 13.89 | 347 | 1171 | 5.29 / 590.74 | 5 | 134 |
Average= | 5.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.16 | 29 | 14.01 | 504 | 205 | 0.20 / 580.64 | 5 | 82 |
2 | 3 | 960.40 | -1 | 14.01 | 504 | 0 | 0.00 / 580.64 | 5 | 82 |
3 | 7 | 2004.84 | 41 | 10.81 | 3014 | 1336 | 1.54 / 581.98 | 82 | 59 |
4 | 13 | 1927.52 | 20 | 12.52 | 2950 | 739 | 2.28 / 582.72 | 5 | 85 |
5 | 13 | 1829.28 | 20 | 12.68 | 2821 | 715 | 2.99 / 583.43 | 5 | 91 |
6 | 13 | 1203.40 | 20 | 13.12 | 2006 | 526 | 3.52 / 583.96 | 5 | 111 |
7 | 13 | 793.80 | 20 | 13.41 | 1464 | 393 | 3.91 / 584.35 | 5 | 123 |
8 | 13 | 143.64 | 20 | 13.95 | 549 | 153 | 4.07 / 584.50 | 5 | 123 |
9 | 8 | 0.16 | 131 | 14.00 | 345 | 633 | 4.70 / 585.14 | 5 | 133 |
10 | 14 | 0.08 | 69 | 13.81 | 337 | 321 | 5.02 / 585.46 | 7 | 126 |
Average= | 5.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.32 | 29 | 14.03 | 509 | 207 | 0.21 / 575.15 | 5 | 91 |
2 | 7 | 2002.88 | 40 | 10.82 | 3010 | 1303 | 1.51 / 576.45 | 5 | 60 |
3 | 13 | 1925.72 | 20 | 12.51 | 2945 | 737 | 2.25 / 577.19 | 5 | 86 |
4 | 13 | 1826.80 | 20 | 12.65 | 2824 | 714 | 2.96 / 577.90 | 5 | 92 |
5 | 13 | 1293.52 | 20 | 13.06 | 2126 | 555 | 3.52 / 578.46 | 5 | 109 |
6 | 13 | 755.24 | 20 | 13.42 | 1404 | 377 | 3.89 / 578.83 | 5 | 123 |
7 | 13 | 117.36 | 20 | 13.97 | 518 | 145 | 4.04 / 578.98 | 5 | 123 |
8 | 8 | 0.04 | 309 | 13.83 | 341 | 1457 | 5.50 / 580.44 | 5 | 133 |
Average= | 5.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.76 | 29 | 14.04 | 497 | 202 | 0.20 / 570.22 | 5 | 92 |
2 | 7 | 2002.36 | 40 | 10.79 | 3029 | 1307 | 1.51 / 571.53 | 92 | 60 |
3 | 13 | 1911.44 | 20 | 12.53 | 2917 | 731 | 2.24 / 572.26 | 5 | 86 |
4 | 13 | 1702.16 | 20 | 12.78 | 2658 | 679 | 2.92 / 572.94 | 5 | 94 |
5 | 13 | 1192.92 | 20 | 13.13 | 1997 | 524 | 3.44 / 573.47 | 5 | 111 |
6 | 13 | 756.08 | 20 | 13.42 | 1406 | 377 | 3.82 / 573.84 | 5 | 124 |
7 | 13 | 105.92 | 20 | 13.98 | 499 | 140 | 3.96 / 573.98 | 5 | 120 |
8 | 8 | 0.08 | 113 | 14.01 | 347 | 549 | 4.51 / 574.53 | 5 | 129 |
9 | 14 | 0.12 | 87 | 13.79 | 341 | 409 | 4.92 / 574.94 | 13 | 124 |
Average= | 5.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.52 | 29 | 14.02 | 506 | 206 | 0.21 / 565.08 | 5 | 94 |
2 | 7 | 2002.48 | 40 | 10.83 | 3020 | 1308 | 1.51 / 566.38 | 5 | 61 |
3 | 13 | 1930.40 | 20 | 12.52 | 2968 | 743 | 2.26 / 567.13 | 5 | 87 |
4 | 13 | 1835.16 | 20 | 12.68 | 2834 | 719 | 2.98 / 567.85 | 5 | 92 |
5 | 13 | 1291.20 | 20 | 13.07 | 2137 | 559 | 3.53 / 568.41 | 5 | 110 |
6 | 13 | 753.16 | 20 | 13.43 | 1400 | 376 | 3.91 / 568.78 | 5 | 122 |
7 | 13 | 207.56 | 20 | 13.88 | 642 | 178 | 4.09 / 568.96 | 5 | 123 |
8 | 13 | 5.52 | 20 | 14.11 | 360 | 102 | 4.19 / 569.06 | 5 | 116 |
9 | 8 | 0.20 | 79 | 14.01 | 350 | 387 | 4.58 / 569.45 | 5 | 129 |
10 | 14 | 0.12 | 121 | 13.80 | 343 | 573 | 5.15 / 570.02 | 5 | 107 |
Average= | 5.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.60 | 25 | 14.05 | 500 | 176 | 0.18 / 559.98 | 5 | 93 |
2 | 10 | 1005.28 | 3 | 13.34 | 1774 | 71 | 0.25 / 560.05 | 5 | 76 |
3 | 3 | 1028.04 | 1 | 12.68 | 1805 | 23 | 0.27 / 560.08 | 5 | 11 |
4 | 7 | 2009.28 | 40 | 10.85 | 3030 | 1315 | 1.58 / 561.39 | 11 | 62 |
5 | 13 | 1932.24 | 20 | 12.53 | 2966 | 743 | 2.33 / 562.14 | 5 | 87 |
6 | 13 | 1628.44 | 20 | 12.87 | 2570 | 662 | 2.99 / 562.80 | 5 | 98 |
7 | 13 | 1208.44 | 20 | 13.14 | 2020 | 531 | 3.52 / 563.33 | 5 | 111 |
8 | 13 | 888.92 | 20 | 13.34 | 1589 | 424 | 3.94 / 563.75 | 5 | 121 |
9 | 13 | 123.20 | 20 | 13.95 | 532 | 148 | 4.09 / 563.90 | 5 | 123 |
10 | 8 | 0.08 | 158 | 13.94 | 350 | 771 | 4.86 / 564.67 | 5 | 133 |
11 | 14 | -0.12 | 42 | 13.75 | 346 | 200 | 5.06 / 564.87 | 7 | 113 |
Average= | 5.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.64 | 57 | 13.85 | 496 | 392 | 0.39 / 554.81 | 5 | 96 |
2 | 2 | 152.56 | 27 | 14.03 | 567 | 215 | 0.61 / 555.02 | 5 | 92 |
3 | 3 | 926.76 | -1 | 14.03 | 567 | 0 | 0.21 / 555.02 | 5 | 92 |
4 | 7 | 2005.72 | 40 | 10.85 | 3030 | 1315 | 1.92 / 556.34 | 92 | 62 |
5 | 13 | 1929.84 | 20 | 12.54 | 2957 | 742 | 2.66 / 557.08 | 5 | 85 |
6 | 13 | 1731.68 | 20 | 12.80 | 2707 | 693 | 3.36 / 557.77 | 5 | 95 |
7 | 13 | 1204.84 | 20 | 13.14 | 1999 | 525 | 3.88 / 558.30 | 5 | 111 |
8 | 13 | 773.28 | 20 | 13.42 | 1422 | 382 | 4.26 / 558.68 | 5 | 122 |
9 | 13 | 132.68 | 20 | 13.95 | 541 | 151 | 4.41 / 558.83 | 5 | 119 |
10 | 8 | 0.00 | 148 | 13.96 | 352 | 727 | 5.14 / 559.56 | 5 | 131 |
11 | 14 | 0.04 | 52 | 13.77 | 347 | 248 | 5.39 / 559.81 | 12 | 130 |
Average= | 5.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.76 | 30 | 14.11 | 417 | 177 | 0.18 / 548.82 | 5 | 5 |
2 | 10 | 1073.92 | 7 | 13.31 | 1039 | 97 | 0.27 / 548.92 | 5 | 5 |
3 | 10 | 1132.12 | 5 | 13.47 | 1391 | 94 | 0.37 / 549.01 | 5 | 39 |
4 | 10 | 1177.96 | 4 | 14.12 | 1292 | 73 | 0.44 / 549.09 | 5 | 41 |
5 | 10 | 1221.00 | 4 | 13.82 | 1456 | 80 | 0.52 / 549.17 | 5 | 42 |
6 | 3 | 1266.12 | 7 | 13.80 | 1468 | 142 | 0.66 / 549.31 | 5 | 57 |
7 | 7 | 2004.04 | 40 | 11.63 | 2140 | 996 | 1.66 / 550.30 | 57 | 33 |
8 | 13 | 1938.12 | 20 | 12.47 | 2989 | 745 | 2.40 / 551.05 | 5 | 84 |
9 | 13 | 1852.60 | 20 | 12.62 | 2869 | 724 | 3.13 / 551.77 | 5 | 90 |
10 | 13 | 1444.72 | 20 | 12.99 | 2342 | 608 | 3.74 / 552.38 | 5 | 105 |
11 | 13 | 1015.16 | 20 | 13.26 | 1748 | 464 | 4.20 / 552.85 | 5 | 117 |
12 | 13 | 471.52 | 20 | 13.63 | 1016 | 277 | 4.48 / 553.12 | 5 | 128 |
13 | 8 | 0.28 | 269 | 13.84 | 348 | 1296 | 5.77 / 554.42 | 5 | 133 |
Average= | 5.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.60 | 30 | 13.99 | 512 | 215 | 0.21 / 543.58 | 5 | 99 |
2 | 7 | 2008.48 | 40 | 10.92 | 3015 | 1317 | 1.53 / 544.90 | 99 | 63 |
3 | 13 | 1940.92 | 20 | 12.49 | 2976 | 743 | 2.28 / 545.64 | 5 | 86 |
4 | 13 | 1848.16 | 20 | 12.68 | 2824 | 716 | 2.99 / 546.36 | 5 | 91 |
5 | 13 | 1203.68 | 20 | 13.13 | 2012 | 528 | 3.52 / 546.89 | 5 | 111 |
6 | 13 | 876.16 | 20 | 13.36 | 1566 | 418 | 3.94 / 547.30 | 5 | 121 |
7 | 13 | 204.08 | 20 | 13.87 | 644 | 179 | 4.12 / 547.48 | 5 | 127 |
8 | 13 | 16.88 | 20 | 14.09 | 372 | 105 | 4.22 / 547.59 | 5 | 112 |
9 | 13 | 4.00 | 20 | 14.02 | 359 | 101 | 4.32 / 547.69 | 5 | 111 |
10 | 8 | -0.08 | 88 | 13.95 | 349 | 428 | 4.75 / 548.12 | 5 | 129 |
11 | 14 | -0.16 | 112 | 13.76 | 343 | 529 | 5.28 / 548.65 | 10 | 52 |
Average= | 5.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.72 | 28 | 14.02 | 510 | 200 | 0.20 / 538.62 | 5 | 101 |
2 | 3 | 1062.64 | 2 | 12.84 | 1855 | 48 | 0.25 / 538.66 | 5 | 44 |
3 | 7 | 2002.96 | 41 | 10.99 | 3016 | 1359 | 1.61 / 540.02 | 44 | 64 |
4 | 13 | 1929.20 | 20 | 12.49 | 2948 | 736 | 2.34 / 540.76 | 5 | 86 |
5 | 13 | 1631.48 | 20 | 12.85 | 2566 | 659 | 3.00 / 541.42 | 5 | 97 |
6 | 13 | 1222.72 | 20 | 13.13 | 2028 | 533 | 3.54 / 541.95 | 5 | 112 |
7 | 13 | 606.32 | 20 | 13.53 | 1200 | 325 | 3.86 / 542.27 | 5 | 126 |
8 | 13 | 85.40 | 20 | 13.99 | 473 | 132 | 3.99 / 542.41 | 5 | 119 |
9 | 8 | 0.00 | 110 | 13.99 | 347 | 534 | 4.53 / 542.94 | 5 | 129 |
10 | 14 | -0.04 | 90 | 13.77 | 343 | 425 | 4.95 / 543.37 | 7 | 117 |
Average= | 5.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.40 | 30 | 14.01 | 502 | 211 | 0.21 / 533.61 | 5 | 87 |
2 | 3 | 958.68 | -1 | 14.01 | 502 | 0 | 0.00 / 533.61 | 5 | 87 |
3 | 7 | 2006.00 | 41 | 10.95 | 3023 | 1357 | 1.57 / 534.97 | 87 | 63 |
4 | 13 | 1929.52 | 20 | 12.51 | 2950 | 738 | 2.31 / 535.70 | 5 | 85 |
5 | 13 | 1635.12 | 20 | 12.83 | 2566 | 658 | 2.96 / 536.36 | 5 | 97 |
6 | 13 | 1212.60 | 20 | 13.12 | 2023 | 531 | 3.50 / 536.89 | 5 | 112 |
7 | 13 | 790.00 | 20 | 13.40 | 1451 | 389 | 3.88 / 537.28 | 5 | 124 |
8 | 13 | 127.96 | 20 | 13.95 | 527 | 147 | 4.03 / 537.43 | 5 | 114 |
9 | 8 | 0.44 | 203 | 13.87 | 350 | 985 | 5.02 / 538.41 | 5 | 130 |
Average= | 5.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.92 | 30 | 13.99 | 497 | 209 | 0.21 / 528.44 | 5 | 99 |
2 | 7 | 2008.72 | 40 | 10.92 | 3022 | 1320 | 1.53 / 529.76 | 99 | 63 |
3 | 13 | 1927.80 | 20 | 12.49 | 2944 | 735 | 2.26 / 530.50 | 5 | 86 |
4 | 13 | 1729.92 | 20 | 12.76 | 2700 | 689 | 2.95 / 531.19 | 5 | 96 |
5 | 13 | 1206.80 | 20 | 13.12 | 2016 | 529 | 3.48 / 531.72 | 5 | 112 |
6 | 13 | 790.12 | 20 | 13.40 | 1450 | 389 | 3.87 / 532.11 | 5 | 123 |
7 | 13 | 64.80 | 20 | 14.02 | 445 | 125 | 4.00 / 532.23 | 5 | 118 |
8 | 13 | 18.48 | 20 | 14.04 | 382 | 107 | 4.10 / 532.34 | 5 | 113 |
9 | 13 | 7.28 | 20 | 13.98 | 365 | 102 | 4.20 / 532.44 | 5 | 112 |
10 | 8 | -0.08 | 94 | 13.93 | 349 | 457 | 4.66 / 532.90 | 5 | 131 |
11 | 14 | -0.08 | 106 | 13.74 | 344 | 501 | 5.16 / 533.40 | 7 | 124 |
Average= | 5.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.24 | 29 | 14.01 | 512 | 208 | 0.21 / 523.30 | 5 | 100 |
2 | 3 | 1033.20 | 1 | 12.36 | 1790 | 22 | 0.23 / 523.32 | 5 | 14 |
3 | 7 | 2010.12 | 40 | 11.01 | 3021 | 1330 | 1.56 / 524.65 | 14 | 65 |
4 | 13 | 1932.32 | 20 | 12.51 | 2952 | 739 | 2.30 / 525.39 | 5 | 86 |
5 | 13 | 1632.32 | 20 | 12.84 | 2569 | 660 | 2.96 / 526.05 | 5 | 98 |
6 | 13 | 1206.28 | 20 | 13.14 | 2008 | 528 | 3.49 / 526.57 | 5 | 112 |
7 | 13 | 700.44 | 20 | 13.47 | 1320 | 356 | 3.84 / 526.93 | 5 | 124 |
8 | 13 | 274.32 | 20 | 13.82 | 727 | 201 | 4.04 / 527.13 | 5 | 121 |
9 | 8 | 0.20 | 230 | 13.84 | 347 | 1105 | 5.15 / 528.24 | 5 | 131 |
Average= | 5.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.04 | 28 | 14.02 | 493 | 194 | 0.19 / 518.26 | 5 | 98 |
2 | 3 | 1021.36 | 1 | 11.07 | 1773 | 20 | 0.21 / 518.28 | 5 | 5 |
3 | 7 | 2003.00 | 40 | 11.04 | 3025 | 1336 | 1.55 / 519.62 | 5 | 65 |
4 | 13 | 1923.72 | 20 | 12.52 | 2952 | 739 | 2.29 / 520.35 | 5 | 86 |
5 | 13 | 1826.20 | 20 | 12.69 | 2799 | 710 | 3.00 / 521.07 | 5 | 92 |
6 | 13 | 1179.28 | 20 | 13.15 | 1976 | 520 | 3.52 / 521.58 | 5 | 112 |
7 | 13 | 759.52 | 20 | 13.43 | 1410 | 379 | 3.90 / 521.96 | 5 | 123 |
8 | 13 | 130.28 | 20 | 13.94 | 536 | 149 | 4.05 / 522.11 | 5 | 119 |
9 | 8 | 0.04 | 171 | 13.90 | 352 | 837 | 4.88 / 522.95 | 5 | 130 |
10 | 14 | -0.12 | 29 | 13.70 | 347 | 138 | 5.02 / 523.09 | 7 | 116 |
Average= | 5.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.60 | 30 | 13.93 | 530 | 221 | 0.22 / 513.00 | 5 | 98 |
2 | 3 | 959.64 | -1 | 13.93 | 530 | 0 | 0.00 / 513.00 | 5 | 98 |
3 | 7 | 2006.24 | 41 | 10.96 | 3032 | 1362 | 1.58 / 514.37 | 98 | 64 |
4 | 13 | 1931.84 | 20 | 12.46 | 2957 | 737 | 2.32 / 515.10 | 5 | 86 |
5 | 13 | 1839.96 | 20 | 12.65 | 2816 | 712 | 3.03 / 515.81 | 5 | 91 |
6 | 13 | 1311.92 | 20 | 13.06 | 2147 | 561 | 3.59 / 516.38 | 5 | 109 |
7 | 13 | 876.72 | 20 | 13.34 | 1573 | 420 | 4.01 / 516.80 | 5 | 122 |
8 | 13 | 210.44 | 20 | 13.85 | 651 | 180 | 4.19 / 516.98 | 5 | 125 |
9 | 13 | 44.12 | 20 | 14.03 | 420 | 118 | 4.31 / 517.09 | 5 | 112 |
10 | 8 | 0.28 | 89 | 14.00 | 357 | 445 | 4.76 / 517.54 | 5 | 134 |
11 | 14 | 0.32 | 111 | 13.76 | 346 | 528 | 5.29 / 518.07 | 9 | 120 |
Average= | 5.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.08 | 32 | 14.00 | 495 | 222 | 0.22 / 507.79 | 5 | 94 |
2 | 3 | 954.16 | -1 | 14.00 | 495 | 0 | 0.00 / 507.79 | 5 | 94 |
3 | 7 | 2006.48 | 40 | 11.02 | 3023 | 1333 | 1.55 / 509.12 | 94 | 66 |
4 | 13 | 1924.28 | 20 | 12.47 | 2943 | 734 | 2.29 / 509.86 | 5 | 86 |
5 | 13 | 1728.84 | 20 | 12.76 | 2703 | 690 | 2.98 / 510.55 | 5 | 95 |
6 | 13 | 1192.64 | 20 | 13.12 | 2003 | 526 | 3.50 / 511.07 | 5 | 114 |
7 | 13 | 758.36 | 20 | 13.43 | 1405 | 377 | 3.88 / 511.45 | 5 | 124 |
8 | 13 | 97.40 | 20 | 13.97 | 488 | 136 | 4.02 / 511.59 | 5 | 113 |
9 | 13 | 20.16 | 20 | 14.03 | 391 | 110 | 4.13 / 511.69 | 5 | 111 |
10 | 13 | 7.52 | 20 | 13.95 | 376 | 105 | 4.23 / 511.80 | 5 | 115 |
11 | 8 | -0.28 | 179 | 13.78 | 357 | 881 | 5.11 / 512.68 | 5 | 132 |
12 | 14 | -0.40 | 21 | 13.60 | 354 | 101 | 5.21 / 512.78 | 7 | 130 |
Average= | 5.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.84 | 36 | 13.97 | 497 | 250 | 0.25 / 502.83 | 5 | 94 |
2 | 3 | 809.88 | -3 | 13.97 | 497 | 0 | 0.00 / 502.83 | 5 | 94 |
3 | 7 | 2008.36 | 40 | 11.00 | 3020 | 1329 | 1.58 / 504.16 | 94 | 66 |
4 | 13 | 1930.80 | 20 | 12.43 | 2941 | 731 | 2.31 / 504.89 | 5 | 86 |
5 | 13 | 1833.12 | 20 | 12.64 | 2815 | 712 | 3.02 / 505.60 | 5 | 92 |
6 | 13 | 1194.60 | 20 | 13.11 | 2001 | 525 | 3.55 / 506.13 | 5 | 113 |
7 | 13 | 576.80 | 20 | 13.54 | 1148 | 311 | 3.86 / 506.44 | 5 | 127 |
8 | 13 | 156.08 | 20 | 13.90 | 566 | 157 | 4.01 / 506.59 | 5 | 118 |
9 | 8 | 0.36 | 145 | 13.92 | 352 | 710 | 4.72 / 507.31 | 5 | 135 |
10 | 14 | 0.12 | 55 | 13.68 | 349 | 263 | 4.99 / 507.57 | 7 | 126 |
Average= | 5.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.76 | 28 | 14.08 | 461 | 182 | 0.18 / 497.57 | 5 | 47 |
2 | 10 | 1048.56 | 5 | 14.05 | 1233 | 87 | 0.27 / 497.66 | 5 | 49 |
3 | 3 | 1143.36 | 4 | 13.15 | 1579 | 83 | 0.35 / 497.74 | 5 | 47 |
4 | 7 | 2004.00 | 41 | 11.10 | 3021 | 1375 | 1.73 / 499.12 | 47 | 66 |
5 | 13 | 1928.36 | 20 | 12.47 | 2950 | 736 | 2.46 / 499.85 | 5 | 85 |
6 | 13 | 1722.16 | 20 | 12.79 | 2684 | 687 | 3.15 / 500.54 | 5 | 95 |
7 | 13 | 1199.92 | 20 | 13.14 | 2002 | 526 | 3.67 / 501.06 | 5 | 112 |
8 | 13 | 678.64 | 20 | 13.48 | 1296 | 349 | 4.02 / 501.41 | 5 | 125 |
9 | 13 | 264.76 | 20 | 13.81 | 705 | 195 | 4.22 / 501.61 | 5 | 120 |
10 | 8 | 0.24 | 180 | 13.88 | 351 | 877 | 5.10 / 502.48 | 5 | 134 |
11 | 14 | 0.28 | 20 | 13.66 | 349 | 95 | 5.19 / 502.58 | 8 | 126 |
Average= | 5.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.48 | 28 | 14.05 | 509 | 200 | 0.20 / 491.40 | 5 | 95 |
2 | 7 | 2002.08 | 41 | 11.07 | 3018 | 1370 | 1.57 / 492.77 | 5 | 66 |
3 | 13 | 1913.80 | 20 | 12.45 | 2933 | 730 | 2.30 / 493.50 | 5 | 87 |
4 | 13 | 1716.00 | 20 | 12.74 | 2679 | 683 | 2.98 / 494.19 | 5 | 96 |
5 | 13 | 1291.76 | 20 | 13.05 | 2129 | 556 | 3.54 / 494.74 | 5 | 110 |
6 | 13 | 739.76 | 20 | 13.42 | 1385 | 372 | 3.91 / 495.11 | 5 | 124 |
7 | 13 | 106.88 | 20 | 13.95 | 504 | 141 | 4.05 / 495.25 | 5 | 118 |
8 | 13 | 55.64 | 20 | 13.98 | 439 | 123 | 4.17 / 495.38 | 5 | 113 |
9 | 13 | 28.48 | 20 | 13.97 | 400 | 112 | 4.29 / 495.49 | 5 | 111 |
10 | 8 | 0.08 | 400 | 13.65 | 348 | 1900 | 6.19 / 497.39 | 5 | 101 |
Average= | 5.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.72 | 27 | 14.02 | 502 | 190 | 0.19 / 486.39 | 5 | 95 |
2 | 3 | 1028.28 | 1 | 12.02 | 1799 | 22 | 0.21 / 486.41 | 5 | 7 |
3 | 7 | 2006.92 | 40 | 11.13 | 3027 | 1348 | 1.56 / 487.76 | 7 | 67 |
4 | 13 | 1928.16 | 20 | 12.48 | 2960 | 739 | 2.30 / 488.50 | 5 | 86 |
5 | 13 | 1612.92 | 20 | 12.85 | 2541 | 653 | 2.95 / 489.15 | 5 | 98 |
6 | 13 | 1101.28 | 20 | 13.19 | 1869 | 493 | 3.44 / 489.64 | 5 | 115 |
7 | 13 | 692.12 | 20 | 13.47 | 1314 | 354 | 3.80 / 490.00 | 5 | 125 |
8 | 13 | 68.40 | 20 | 14.01 | 449 | 126 | 3.92 / 490.12 | 5 | 109 |
9 | 8 | -0.04 | 223 | 13.83 | 351 | 1083 | 5.01 / 491.20 | 5 | 129 |
Average= | 5.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.08 | 29 | 14.04 | 494 | 201 | 0.20 / 481.24 | 5 | 89 |
2 | 3 | 955.32 | -1 | 14.04 | 494 | 0 | 0.00 / 481.24 | 5 | 89 |
3 | 7 | 2001.48 | 40 | 11.17 | 3017 | 1348 | 1.55 / 482.59 | 89 | 67 |
4 | 13 | 1916.16 | 20 | 12.46 | 2938 | 732 | 2.28 / 483.32 | 5 | 86 |
5 | 13 | 1715.80 | 20 | 12.76 | 2676 | 683 | 2.96 / 484.01 | 5 | 95 |
6 | 13 | 1291.36 | 20 | 13.06 | 2134 | 557 | 3.52 / 484.56 | 5 | 110 |
7 | 13 | 842.04 | 20 | 13.36 | 1534 | 410 | 3.93 / 484.97 | 5 | 123 |
8 | 13 | 176.44 | 20 | 13.88 | 598 | 166 | 4.10 / 485.14 | 5 | 120 |
9 | 8 | -0.04 | 217 | 13.84 | 352 | 1057 | 5.15 / 486.20 | 5 | 134 |
Average= | 5.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.52 | 29 | 14.04 | 501 | 204 | 0.20 / 475.92 | 5 | 97 |
2 | 7 | 2004.64 | 40 | 11.11 | 3021 | 1343 | 1.55 / 477.27 | 97 | 67 |
3 | 13 | 1926.08 | 20 | 12.43 | 2954 | 734 | 2.28 / 478.00 | 5 | 85 |
4 | 13 | 1830.76 | 20 | 12.63 | 2829 | 715 | 3.00 / 478.72 | 5 | 92 |
5 | 13 | 1180.84 | 20 | 13.13 | 1980 | 520 | 3.52 / 479.24 | 5 | 112 |
6 | 13 | 670.44 | 20 | 13.48 | 1284 | 346 | 3.86 / 479.58 | 5 | 125 |
7 | 13 | 124.28 | 20 | 13.95 | 529 | 148 | 4.01 / 479.73 | 5 | 122 |
8 | 8 | 0.04 | 275 | 13.80 | 346 | 1313 | 5.32 / 481.04 | 5 | 130 |
Average= | 5.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.12 | 28 | 14.04 | 505 | 199 | 0.20 / 470.90 | 5 | 97 |
2 | 3 | 1029.72 | 1 | 12.00 | 1794 | 22 | 0.22 / 470.93 | 5 | 10 |
3 | 7 | 2004.64 | 41 | 11.17 | 3022 | 1384 | 1.60 / 472.31 | 10 | 68 |
4 | 13 | 1920.72 | 20 | 12.45 | 2941 | 732 | 2.34 / 473.04 | 5 | 86 |
5 | 13 | 1722.40 | 20 | 12.74 | 2687 | 685 | 3.02 / 473.73 | 5 | 95 |
6 | 13 | 1275.28 | 20 | 13.06 | 2112 | 552 | 3.57 / 474.28 | 5 | 111 |
7 | 13 | 631.72 | 20 | 13.51 | 1234 | 333 | 3.91 / 474.61 | 5 | 125 |
8 | 13 | 114.56 | 20 | 13.96 | 513 | 143 | 4.05 / 474.76 | 5 | 121 |
9 | 8 | 0.20 | 107 | 13.98 | 350 | 524 | 4.57 / 475.28 | 5 | 132 |
10 | 14 | 0.12 | 93 | 13.74 | 345 | 441 | 5.01 / 475.72 | 8 | 129 |
Average= | 5.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.32 | 28 | 14.05 | 505 | 199 | 0.20 / 465.87 | 5 | 96 |
2 | 7 | 2001.80 | 40 | 11.22 | 3011 | 1351 | 1.55 / 467.22 | 96 | 68 |
3 | 13 | 1915.08 | 20 | 12.43 | 2929 | 728 | 2.28 / 467.95 | 5 | 86 |
4 | 13 | 1726.84 | 20 | 12.75 | 2685 | 685 | 2.96 / 468.63 | 5 | 94 |
5 | 13 | 1299.96 | 20 | 13.04 | 2143 | 559 | 3.52 / 469.19 | 5 | 109 |
6 | 13 | 763.08 | 20 | 13.41 | 1411 | 378 | 3.90 / 469.57 | 5 | 123 |
7 | 13 | 203.08 | 20 | 13.86 | 635 | 176 | 4.08 / 469.74 | 5 | 123 |
8 | 8 | -0.12 | 160 | 13.91 | 348 | 775 | 4.85 / 470.52 | 5 | 134 |
9 | 14 | -0.04 | 40 | 13.70 | 342 | 187 | 5.04 / 470.71 | 8 | 120 |
Average= | 5.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.40 | 28 | 14.05 | 505 | 199 | 0.20 / 460.75 | 5 | 98 |
2 | 7 | 2002.24 | 40 | 11.18 | 3025 | 1353 | 1.55 / 462.10 | 5 | 68 |
3 | 13 | 1918.56 | 20 | 12.43 | 2929 | 728 | 2.28 / 462.83 | 5 | 85 |
4 | 13 | 1820.64 | 20 | 12.61 | 2809 | 708 | 2.99 / 463.54 | 5 | 92 |
5 | 13 | 1257.48 | 20 | 13.08 | 2085 | 545 | 3.53 / 464.09 | 5 | 111 |
6 | 13 | 805.20 | 20 | 13.37 | 1477 | 395 | 3.93 / 464.48 | 5 | 123 |
7 | 13 | 72.36 | 20 | 14.00 | 456 | 128 | 4.06 / 464.61 | 5 | 118 |
8 | 8 | 0.12 | 222 | 13.83 | 345 | 1059 | 5.12 / 465.67 | 5 | 130 |
Average= | 5.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.68 | 28 | 14.07 | 517 | 204 | 0.20 / 455.77 | 5 | 94 |
2 | 7 | 2005.28 | 41 | 11.22 | 3026 | 1392 | 1.60 / 457.17 | 5 | 68 |
3 | 13 | 1917.48 | 20 | 12.44 | 2941 | 732 | 2.33 / 457.90 | 5 | 86 |
4 | 13 | 1711.88 | 20 | 12.76 | 2670 | 681 | 3.01 / 458.58 | 5 | 96 |
5 | 13 | 1190.28 | 20 | 13.12 | 1995 | 523 | 3.53 / 459.10 | 5 | 113 |
6 | 13 | 654.76 | 20 | 13.48 | 1264 | 341 | 3.87 / 459.44 | 5 | 125 |
7 | 13 | 63.60 | 20 | 14.00 | 445 | 125 | 4.00 / 459.57 | 5 | 113 |
8 | 8 | -0.04 | 200 | 13.83 | 356 | 985 | 4.98 / 460.55 | 5 | 132 |
Average= | 5.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.12 | 28 | 14.06 | 493 | 194 | 0.19 / 450.83 | 5 | 89 |
2 | 7 | 2002.24 | 40 | 11.24 | 3019 | 1357 | 1.55 / 452.19 | 89 | 68 |
3 | 13 | 1919.20 | 20 | 12.47 | 2934 | 732 | 2.28 / 452.92 | 5 | 86 |
4 | 13 | 1714.96 | 20 | 12.74 | 2662 | 678 | 2.96 / 453.60 | 5 | 95 |
5 | 13 | 1182.64 | 20 | 13.12 | 1995 | 523 | 3.48 / 454.12 | 5 | 114 |
6 | 13 | 669.88 | 20 | 13.47 | 1287 | 347 | 3.83 / 454.47 | 5 | 124 |
7 | 13 | 75.04 | 20 | 14.00 | 458 | 128 | 3.96 / 454.60 | 5 | 115 |
8 | 8 | 0.12 | 115 | 13.96 | 354 | 568 | 4.53 / 455.16 | 5 | 130 |
9 | 14 | -0.08 | 85 | 13.72 | 349 | 407 | 4.94 / 455.57 | 5 | 126 |
Average= | 5.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.24 | 28 | 14.09 | 503 | 198 | 0.20 / 445.49 | 5 | 90 |
2 | 7 | 2004.04 | 40 | 11.29 | 3030 | 1368 | 1.57 / 446.86 | 5 | 69 |
3 | 13 | 1922.76 | 20 | 12.47 | 2947 | 735 | 2.30 / 447.60 | 5 | 86 |
4 | 13 | 1628.20 | 20 | 12.84 | 2565 | 659 | 2.96 / 448.25 | 5 | 98 |
5 | 13 | 1429.80 | 20 | 12.98 | 2316 | 601 | 3.56 / 448.86 | 5 | 106 |
6 | 13 | 773.00 | 20 | 13.40 | 1428 | 383 | 3.94 / 449.24 | 5 | 124 |
7 | 13 | 121.72 | 20 | 13.96 | 515 | 144 | 4.09 / 449.38 | 5 | 111 |
8 | 13 | 11.40 | 20 | 14.07 | 369 | 104 | 4.19 / 449.49 | 5 | 112 |
9 | 8 | -0.04 | 244 | 13.78 | 342 | 1150 | 5.34 / 450.64 | 5 | 133 |
Average= | 5.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.76 | 28 | 14.11 | 508 | 201 | 0.20 / 440.46 | 5 | 85 |
2 | 7 | 2001.56 | 41 | 11.25 | 3024 | 1395 | 1.60 / 441.85 | 5 | 69 |
3 | 13 | 1922.28 | 20 | 12.46 | 2939 | 732 | 2.33 / 442.59 | 5 | 85 |
4 | 13 | 1833.00 | 20 | 12.64 | 2827 | 715 | 3.04 / 443.30 | 5 | 92 |
5 | 13 | 1293.08 | 20 | 13.05 | 2126 | 555 | 3.60 / 443.86 | 5 | 109 |
6 | 13 | 642.72 | 20 | 13.50 | 1245 | 336 | 3.93 / 444.19 | 5 | 126 |
7 | 13 | 114.96 | 20 | 13.96 | 508 | 142 | 4.08 / 444.33 | 5 | 107 |
8 | 8 | 0.16 | 153 | 13.93 | 347 | 740 | 4.82 / 445.07 | 5 | 133 |
9 | 14 | -0.04 | 47 | 13.72 | 342 | 221 | 5.04 / 445.29 | 6 | 123 |
Average= | 5.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.92 | 28 | 14.14 | 506 | 200 | 0.20 / 435.15 | 5 | 83 |
2 | 7 | 2003.48 | 40 | 11.22 | 3025 | 1358 | 1.56 / 436.51 | 83 | 67 |
3 | 13 | 1922.24 | 20 | 12.45 | 2951 | 735 | 2.29 / 437.25 | 5 | 85 |
4 | 13 | 1836.24 | 20 | 12.63 | 2838 | 717 | 3.01 / 437.96 | 5 | 91 |
5 | 13 | 1739.00 | 20 | 12.73 | 2709 | 690 | 3.70 / 438.65 | 5 | 96 |
6 | 13 | 933.60 | 20 | 13.29 | 1645 | 437 | 4.14 / 439.09 | 5 | 118 |
7 | 13 | 284.44 | 20 | 13.79 | 749 | 207 | 4.34 / 439.30 | 5 | 124 |
8 | 8 | 0.24 | 156 | 13.93 | 347 | 754 | 5.10 / 440.05 | 5 | 136 |
9 | 14 | 0.00 | 44 | 13.73 | 343 | 207 | 5.30 / 440.26 | 16 | 122 |
Average= | 5.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.40 | 28 | 14.16 | 495 | 196 | 0.20 / 429.90 | 5 | 78 |
2 | 7 | 2005.68 | 40 | 11.29 | 3032 | 1369 | 1.57 / 431.27 | 78 | 69 |
3 | 13 | 1922.92 | 20 | 12.47 | 2949 | 735 | 2.30 / 432.01 | 5 | 85 |
4 | 13 | 1628.08 | 20 | 12.83 | 2561 | 657 | 2.96 / 432.66 | 5 | 97 |
5 | 13 | 1212.44 | 20 | 13.12 | 2025 | 531 | 3.49 / 433.20 | 5 | 111 |
6 | 13 | 890.88 | 20 | 13.34 | 1592 | 425 | 3.91 / 433.62 | 5 | 121 |
7 | 13 | 56.56 | 20 | 14.04 | 426 | 120 | 4.03 / 433.74 | 5 | 106 |
8 | 8 | -0.12 | 254 | 13.84 | 345 | 1213 | 5.25 / 434.95 | 5 | 129 |
Average= | 5.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.68 | 27 | 14.14 | 496 | 189 | 0.19 / 424.73 | 5 | 83 |
2 | 7 | 2002.96 | 41 | 11.29 | 3019 | 1397 | 1.59 / 426.13 | 5 | 69 |
3 | 13 | 1911.64 | 20 | 12.48 | 2928 | 731 | 2.32 / 426.86 | 5 | 86 |
4 | 13 | 1596.40 | 20 | 12.85 | 2533 | 651 | 2.97 / 427.51 | 5 | 98 |
5 | 13 | 975.76 | 20 | 13.27 | 1704 | 452 | 3.42 / 427.97 | 5 | 117 |
6 | 13 | 680.44 | 20 | 13.49 | 1298 | 350 | 3.77 / 428.32 | 5 | 124 |
7 | 13 | 68.52 | 20 | 14.04 | 446 | 125 | 3.90 / 428.44 | 5 | 124 |
8 | 8 | 0.04 | 265 | 13.85 | 345 | 1266 | 5.16 / 429.71 | 5 | 131 |
Average= | 5.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.80 | 27 | 14.15 | 501 | 191 | 0.19 / 419.67 | 5 | 82 |
2 | 7 | 2004.48 | 40 | 11.25 | 3032 | 1364 | 1.56 / 421.04 | 82 | 69 |
3 | 13 | 1920.12 | 20 | 12.46 | 2951 | 735 | 2.29 / 421.77 | 5 | 85 |
4 | 13 | 1720.08 | 20 | 12.77 | 2686 | 686 | 2.98 / 422.46 | 5 | 95 |
5 | 13 | 1396.00 | 20 | 13.01 | 2274 | 592 | 3.57 / 423.05 | 5 | 106 |
6 | 13 | 567.88 | 20 | 13.58 | 1139 | 309 | 3.88 / 423.36 | 5 | 124 |
7 | 13 | 366.08 | 20 | 13.75 | 849 | 233 | 4.11 / 423.59 | 5 | 120 |
8 | 8 | 0.24 | 124 | 14.00 | 343 | 595 | 4.71 / 424.19 | 5 | 129 |
9 | 14 | 0.08 | 76 | 13.77 | 340 | 356 | 5.06 / 424.54 | 8 | 122 |
Average= | 5.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.32 | 27 | 14.17 | 496 | 190 | 0.19 / 414.23 | 5 | 78 |
2 | 7 | 2002.88 | 40 | 11.28 | 3021 | 1363 | 1.55 / 415.59 | 78 | 69 |
3 | 13 | 1923.48 | 20 | 12.46 | 2948 | 735 | 2.29 / 416.33 | 5 | 85 |
4 | 13 | 1626.76 | 20 | 12.84 | 2570 | 660 | 2.95 / 416.99 | 5 | 98 |
5 | 13 | 1220.64 | 20 | 13.13 | 2029 | 533 | 3.48 / 417.52 | 5 | 111 |
6 | 13 | 1022.56 | 20 | 13.25 | 1770 | 469 | 3.95 / 417.99 | 5 | 118 |
7 | 13 | 52.56 | 20 | 14.08 | 419 | 118 | 4.07 / 418.10 | 5 | 119 |
8 | 8 | 0.20 | 294 | 13.85 | 338 | 1376 | 5.44 / 419.48 | 5 | 132 |
Average= | 5.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.52 | 27 | 14.15 | 500 | 191 | 0.19 / 408.78 | 5 | 82 |
2 | 7 | 2002.68 | 40 | 11.29 | 3021 | 1364 | 1.56 / 410.15 | 82 | 69 |
3 | 13 | 1917.32 | 20 | 12.50 | 2940 | 735 | 2.29 / 410.88 | 5 | 85 |
4 | 13 | 1717.96 | 20 | 12.76 | 2689 | 686 | 2.98 / 411.57 | 5 | 95 |
5 | 13 | 1209.36 | 20 | 13.14 | 2027 | 533 | 3.51 / 412.10 | 5 | 112 |
6 | 13 | 795.80 | 20 | 13.42 | 1461 | 392 | 3.90 / 412.49 | 5 | 121 |
7 | 13 | 71.68 | 20 | 14.05 | 452 | 127 | 4.03 / 412.62 | 5 | 122 |
8 | 8 | -0.12 | 300 | 13.84 | 341 | 1416 | 5.44 / 414.04 | 5 | 131 |
Average= | 5.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.24 | 27 | 14.18 | 494 | 189 | 0.19 / 403.53 | 5 | 86 |
2 | 7 | 2006.36 | 41 | 11.27 | 3027 | 1399 | 1.59 / 404.93 | 86 | 62 |
3 | 13 | 1912.40 | 20 | 12.50 | 2925 | 731 | 2.32 / 405.66 | 5 | 83 |
4 | 13 | 1598.60 | 20 | 12.89 | 2508 | 647 | 2.97 / 406.30 | 5 | 96 |
5 | 13 | 1196.60 | 20 | 13.15 | 2000 | 526 | 3.49 / 406.83 | 5 | 110 |
6 | 13 | 667.88 | 20 | 13.51 | 1286 | 347 | 3.84 / 407.18 | 5 | 125 |
7 | 13 | 35.72 | 20 | 14.09 | 401 | 113 | 3.95 / 407.29 | 5 | 120 |
8 | 8 | 0.00 | 274 | 13.82 | 344 | 1303 | 5.25 / 408.59 | 5 | 136 |
Average= | 5.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.96 | 29 | 14.16 | 510 | 209 | 0.21 / 398.24 | 5 | 83 |
2 | 3 | 956.24 | -1 | 14.16 | 510 | 0 | 0.00 / 398.24 | 5 | 83 |
3 | 7 | 2002.84 | 40 | 11.30 | 3027 | 1368 | 1.58 / 399.61 | 83 | 70 |
4 | 13 | 1912.32 | 20 | 12.49 | 2931 | 732 | 2.31 / 400.34 | 5 | 86 |
5 | 13 | 1724.48 | 20 | 12.81 | 2683 | 687 | 3.00 / 401.03 | 5 | 95 |
6 | 13 | 1291.80 | 20 | 13.09 | 2133 | 558 | 3.56 / 401.59 | 5 | 109 |
7 | 13 | 648.60 | 20 | 13.53 | 1251 | 339 | 3.89 / 401.93 | 5 | 123 |
8 | 13 | 101.96 | 20 | 14.03 | 491 | 138 | 4.03 / 402.07 | 5 | 123 |
9 | 8 | 0.16 | 270 | 13.86 | 340 | 1272 | 5.30 / 403.34 | 5 | 129 |
Average= | 5.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.64 | 30 | 14.16 | 505 | 215 | 0.21 / 392.74 | 5 | 79 |
2 | 3 | 914.68 | -1 | 14.16 | 505 | 0 | 0.00 / 392.74 | 5 | 79 |
3 | 7 | 2004.44 | 40 | 11.20 | 3025 | 1355 | 1.57 / 394.09 | 79 | 69 |
4 | 13 | 1914.92 | 20 | 12.50 | 2939 | 735 | 2.30 / 394.83 | 5 | 86 |
5 | 13 | 1820.88 | 20 | 12.67 | 2813 | 713 | 3.02 / 395.54 | 5 | 91 |
6 | 13 | 1380.44 | 20 | 13.04 | 2250 | 587 | 3.60 / 396.13 | 5 | 107 |
7 | 13 | 737.44 | 20 | 13.46 | 1370 | 369 | 3.97 / 396.49 | 5 | 123 |
8 | 13 | 182.92 | 20 | 13.93 | 604 | 168 | 4.14 / 396.66 | 5 | 120 |
9 | 8 | 0.12 | 290 | 13.83 | 342 | 1372 | 5.51 / 398.03 | 5 | 137 |
Average= | 5.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.00 | 28 | 14.15 | 495 | 196 | 0.20 / 387.34 | 5 | 88 |
2 | 10 | 1002.92 | 3 | 13.50 | 1765 | 71 | 0.27 / 387.41 | 5 | 78 |
3 | 7 | 2002.36 | 41 | 11.26 | 3025 | 1397 | 1.66 / 388.80 | 78 | 70 |
4 | 13 | 1921.04 | 20 | 12.52 | 2941 | 736 | 2.40 / 389.54 | 5 | 86 |
5 | 13 | 1825.32 | 20 | 12.67 | 2831 | 717 | 3.12 / 390.26 | 5 | 92 |
6 | 13 | 1195.88 | 20 | 13.16 | 2015 | 530 | 3.65 / 390.79 | 5 | 112 |
7 | 13 | 786.08 | 20 | 13.44 | 1456 | 391 | 4.04 / 391.18 | 5 | 123 |
8 | 13 | 127.88 | 20 | 14.00 | 524 | 147 | 4.19 / 391.33 | 5 | 117 |
9 | 8 | 0.20 | 251 | 13.88 | 343 | 1195 | 5.38 / 392.52 | 5 | 131 |
Average= | 5.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.92 | 29 | 14.13 | 511 | 209 | 0.21 / 382.23 | 5 | 82 |
2 | 3 | 962.24 | -1 | 14.13 | 511 | 0 | 0.00 / 382.23 | 5 | 82 |
3 | 7 | 2004.52 | 40 | 11.18 | 3019 | 1350 | 1.56 / 383.58 | 82 | 70 |
4 | 13 | 1931.00 | 20 | 12.47 | 2956 | 737 | 2.30 / 384.32 | 5 | 85 |
5 | 13 | 1843.80 | 20 | 12.68 | 2837 | 719 | 3.02 / 385.04 | 5 | 91 |
6 | 13 | 1304.20 | 20 | 13.09 | 2149 | 563 | 3.58 / 385.60 | 5 | 109 |
7 | 13 | 767.80 | 20 | 13.44 | 1428 | 384 | 3.96 / 385.98 | 5 | 123 |
8 | 13 | 247.08 | 20 | 13.88 | 694 | 193 | 4.16 / 386.18 | 5 | 120 |
9 | 8 | -0.04 | 147 | 13.97 | 348 | 715 | 4.87 / 386.89 | 5 | 132 |
10 | 14 | -0.08 | 53 | 13.75 | 343 | 250 | 5.12 / 387.14 | 6 | 116 |
Average= | 5.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.80 | 29 | 14.12 | 498 | 204 | 0.20 / 376.63 | 5 | 91 |
2 | 7 | 2004.52 | 41 | 11.21 | 3029 | 1392 | 1.60 / 378.02 | 91 | 69 |
3 | 13 | 1931.88 | 20 | 12.49 | 2970 | 742 | 2.34 / 378.76 | 5 | 86 |
4 | 13 | 1632.56 | 20 | 12.89 | 2570 | 663 | 3.00 / 379.42 | 5 | 98 |
5 | 13 | 1430.20 | 20 | 13.03 | 2304 | 600 | 3.60 / 380.03 | 5 | 105 |
6 | 13 | 772.44 | 20 | 13.45 | 1424 | 383 | 3.98 / 380.41 | 5 | 123 |
7 | 13 | 356.88 | 20 | 13.79 | 838 | 231 | 4.22 / 380.64 | 5 | 121 |
8 | 8 | 0.08 | 289 | 13.81 | 346 | 1381 | 5.60 / 382.02 | 5 | 131 |
Average= | 5.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.36 | 29 | 14.14 | 489 | 201 | 0.20 / 371.62 | 5 | 93 |
2 | 7 | 2009.56 | 40 | 11.13 | 3053 | 1359 | 1.56 / 372.98 | 93 | 69 |
3 | 13 | 1925.16 | 20 | 12.51 | 2957 | 740 | 2.30 / 373.72 | 5 | 86 |
4 | 13 | 1609.60 | 20 | 12.91 | 2540 | 656 | 2.96 / 374.38 | 5 | 98 |
5 | 13 | 1186.92 | 20 | 13.20 | 2001 | 528 | 3.48 / 374.90 | 5 | 113 |
6 | 13 | 764.16 | 20 | 13.47 | 1415 | 381 | 3.86 / 375.29 | 5 | 123 |
7 | 13 | 174.92 | 20 | 13.95 | 583 | 163 | 4.03 / 375.45 | 5 | 113 |
8 | 8 | 0.04 | 137 | 13.98 | 352 | 674 | 4.70 / 376.12 | 5 | 129 |
9 | 14 | 0.12 | 63 | 13.75 | 348 | 301 | 5.00 / 376.42 | 6 | 121 |
Average= | 5.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.88 | 29 | 14.15 | 494 | 203 | 0.20 / 366.47 | 5 | 91 |
2 | 3 | 1027.84 | 1 | 12.52 | 1818 | 23 | 0.23 / 366.49 | 5 | 10 |
3 | 7 | 2006.20 | 40 | 11.14 | 3024 | 1347 | 1.57 / 367.84 | 10 | 70 |
4 | 13 | 1930.96 | 20 | 12.50 | 2956 | 739 | 2.31 / 368.58 | 5 | 86 |
5 | 13 | 1731.36 | 20 | 12.81 | 2696 | 691 | 3.00 / 369.27 | 5 | 96 |
6 | 13 | 1202.80 | 20 | 13.17 | 2019 | 532 | 3.53 / 369.80 | 5 | 113 |
7 | 13 | 889.68 | 20 | 13.40 | 1591 | 426 | 3.96 / 370.22 | 5 | 121 |
8 | 13 | 338.00 | 20 | 13.81 | 815 | 225 | 4.19 / 370.45 | 5 | 122 |
9 | 8 | -0.04 | 150 | 13.96 | 350 | 733 | 4.92 / 371.18 | 5 | 132 |
10 | 14 | -0.16 | 50 | 13.74 | 347 | 238 | 5.16 / 371.42 | 10 | 127 |
Average= | 5.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.68 | 29 | 14.16 | 492 | 202 | 0.20 / 361.47 | 5 | 87 |
2 | 7 | 2002.88 | 41 | 11.08 | 3040 | 1381 | 1.58 / 362.85 | 87 | 69 |
3 | 13 | 1925.44 | 20 | 12.52 | 2964 | 742 | 2.33 / 363.60 | 5 | 85 |
4 | 13 | 1625.76 | 20 | 12.91 | 2566 | 663 | 2.99 / 364.26 | 5 | 98 |
5 | 13 | 1220.24 | 20 | 13.19 | 2045 | 539 | 3.53 / 364.80 | 5 | 112 |
6 | 13 | 795.00 | 20 | 13.46 | 1463 | 394 | 3.92 / 365.19 | 5 | 122 |
7 | 13 | 28.80 | 20 | 14.13 | 393 | 111 | 4.03 / 365.30 | 5 | 120 |
8 | 8 | 0.08 | 124 | 13.98 | 346 | 600 | 4.63 / 365.90 | 5 | 132 |
9 | 14 | 0.12 | 76 | 13.78 | 344 | 360 | 4.99 / 366.26 | 7 | 125 |
Average= | 5.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.60 | 28 | 14.19 | 496 | 197 | 0.20 / 356.08 | 5 | 87 |
2 | 7 | 2004.00 | 40 | 11.21 | 3015 | 1352 | 1.55 / 357.43 | 5 | 69 |
3 | 13 | 1915.84 | 20 | 12.57 | 2950 | 742 | 2.29 / 358.17 | 5 | 87 |
4 | 13 | 1595.24 | 20 | 12.95 | 2520 | 653 | 2.94 / 358.82 | 5 | 99 |
5 | 13 | 1297.84 | 20 | 13.15 | 2138 | 562 | 3.51 / 359.39 | 5 | 110 |
6 | 13 | 850.56 | 20 | 13.44 | 1529 | 411 | 3.92 / 359.80 | 5 | 122 |
7 | 13 | 283.08 | 20 | 13.88 | 742 | 206 | 4.12 / 360.00 | 5 | 121 |
8 | 8 | -0.12 | 266 | 13.87 | 344 | 1269 | 5.39 / 361.27 | 5 | 129 |
Average= | 5.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.44 | 28 | 14.17 | 510 | 202 | 0.20 / 350.71 | 5 | 87 |
2 | 7 | 2005.36 | 40 | 11.14 | 3046 | 1357 | 1.56 / 352.07 | 87 | 69 |
3 | 13 | 1929.20 | 20 | 12.55 | 2953 | 741 | 2.30 / 352.81 | 5 | 86 |
4 | 13 | 1839.28 | 20 | 12.73 | 2840 | 723 | 3.02 / 353.54 | 5 | 92 |
5 | 13 | 1087.64 | 20 | 13.28 | 1855 | 493 | 3.52 / 354.03 | 5 | 115 |
6 | 13 | 668.00 | 20 | 13.58 | 1284 | 349 | 3.87 / 354.38 | 5 | 124 |
7 | 13 | 62.44 | 20 | 14.11 | 441 | 124 | 3.99 / 354.50 | 5 | 121 |
8 | 8 | 0.24 | 288 | 13.87 | 345 | 1378 | 5.37 / 355.88 | 5 | 130 |
Average= | 5.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.20 | 28 | 14.17 | 511 | 203 | 0.20 / 345.36 | 5 | 86 |
2 | 7 | 2006.72 | 40 | 11.16 | 3024 | 1350 | 1.55 / 346.71 | 5 | 68 |
3 | 13 | 1917.16 | 20 | 12.57 | 2957 | 743 | 2.30 / 347.45 | 5 | 87 |
4 | 13 | 1709.60 | 20 | 12.87 | 2680 | 690 | 2.99 / 348.14 | 5 | 97 |
5 | 13 | 1174.12 | 20 | 13.24 | 1980 | 524 | 3.51 / 348.67 | 5 | 114 |
6 | 13 | 853.28 | 20 | 13.44 | 1546 | 416 | 3.93 / 349.08 | 5 | 123 |
7 | 13 | 38.28 | 20 | 14.13 | 406 | 115 | 4.04 / 349.20 | 5 | 119 |
8 | 8 | 0.16 | 277 | 13.85 | 343 | 1316 | 5.36 / 350.51 | 5 | 138 |
Average= | 5.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.68 | 27 | 14.15 | 502 | 192 | 0.19 / 340.02 | 5 | 96 |
2 | 3 | 1047.64 | 1 | 13.25 | 1852 | 25 | 0.22 / 340.05 | 5 | 33 |
3 | 7 | 2004.68 | 40 | 11.13 | 3031 | 1349 | 1.57 / 341.40 | 33 | 69 |
4 | 13 | 1925.04 | 20 | 12.56 | 2961 | 744 | 2.31 / 342.14 | 5 | 87 |
5 | 13 | 1614.64 | 20 | 12.96 | 2553 | 662 | 2.97 / 342.80 | 5 | 99 |
6 | 13 | 1283.00 | 20 | 13.19 | 2121 | 560 | 3.53 / 343.36 | 5 | 112 |
7 | 13 | 733.24 | 20 | 13.53 | 1372 | 371 | 3.90 / 343.73 | 5 | 125 |
8 | 13 | 6.84 | 20 | 14.16 | 362 | 103 | 4.00 / 343.83 | 5 | 118 |
9 | 8 | -0.16 | 277 | 13.83 | 345 | 1322 | 5.33 / 345.16 | 5 | 134 |
Average= | 5.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.08 | 29 | 14.11 | 502 | 205 | 0.21 / 335.01 | 5 | 93 |
2 | 3 | 963.28 | -1 | 14.11 | 502 | 0 | 0.00 / 335.01 | 5 | 93 |
3 | 7 | 2005.00 | 40 | 11.12 | 3028 | 1347 | 1.55 / 336.36 | 93 | 69 |
4 | 13 | 1912.36 | 20 | 12.59 | 2938 | 740 | 2.29 / 337.10 | 5 | 87 |
5 | 13 | 1596.36 | 20 | 12.96 | 2528 | 655 | 2.95 / 337.75 | 5 | 100 |
6 | 13 | 1110.52 | 20 | 13.30 | 1886 | 502 | 3.45 / 338.25 | 5 | 116 |
7 | 13 | 692.28 | 20 | 13.57 | 1316 | 357 | 3.81 / 338.61 | 5 | 125 |
8 | 13 | 363.40 | 20 | 13.83 | 845 | 234 | 4.04 / 338.85 | 5 | 124 |
9 | 8 | 0.04 | 191 | 13.91 | 354 | 941 | 4.98 / 339.79 | 5 | 132 |
10 | 14 | 0.04 | 9 | 13.71 | 353 | 44 | 5.02 / 339.83 | 10 | 125 |
Average= | 5.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.44 | 29 | 14.13 | 511 | 209 | 0.21 / 329.41 | 5 | 102 |
2 | 7 | 2003.84 | 40 | 11.22 | 3027 | 1359 | 1.57 / 330.76 | 102 | 71 |
3 | 13 | 1929.44 | 20 | 12.59 | 2961 | 746 | 2.31 / 331.51 | 5 | 90 |
4 | 13 | 1831.52 | 20 | 12.77 | 2823 | 721 | 3.03 / 332.23 | 5 | 96 |
5 | 13 | 1285.68 | 20 | 13.18 | 2134 | 563 | 3.60 / 332.79 | 5 | 113 |
6 | 13 | 832.00 | 20 | 13.48 | 1521 | 410 | 4.01 / 333.20 | 5 | 123 |
7 | 13 | 250.72 | 20 | 13.91 | 694 | 193 | 4.20 / 333.40 | 5 | 120 |
8 | 8 | 0.16 | 290 | 13.81 | 352 | 1410 | 5.61 / 334.81 | 5 | 130 |
Average= | 5.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.24 | 29 | 14.12 | 494 | 202 | 0.20 / 324.22 | 5 | 97 |
2 | 7 | 2005.64 | 41 | 11.28 | 3022 | 1398 | 1.60 / 325.62 | 97 | 70 |
3 | 13 | 1931.92 | 20 | 12.63 | 2973 | 751 | 2.35 / 326.37 | 5 | 89 |
4 | 13 | 1627.60 | 20 | 13.00 | 2562 | 666 | 3.02 / 327.04 | 5 | 101 |
5 | 13 | 1104.92 | 20 | 13.30 | 1888 | 502 | 3.52 / 327.54 | 5 | 118 |
6 | 13 | 458.24 | 20 | 13.75 | 991 | 273 | 3.79 / 327.81 | 5 | 126 |
7 | 13 | 72.68 | 20 | 14.08 | 460 | 130 | 3.92 / 327.94 | 5 | 110 |
8 | 8 | 0.24 | 258 | 13.84 | 351 | 1253 | 5.17 / 329.20 | 5 | 132 |
Average= | 5.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.16 | 29 | 14.16 | 512 | 210 | 0.21 / 319.15 | 5 | 93 |
2 | 7 | 2006.76 | 40 | 11.24 | 3033 | 1364 | 1.57 / 320.52 | 93 | 69 |
3 | 13 | 1929.88 | 20 | 12.62 | 2962 | 748 | 2.32 / 321.26 | 5 | 88 |
4 | 13 | 1834.20 | 20 | 12.78 | 2827 | 723 | 3.04 / 321.99 | 5 | 94 |
5 | 13 | 1068.60 | 20 | 13.33 | 1840 | 491 | 3.53 / 322.48 | 5 | 117 |
6 | 13 | 748.44 | 20 | 13.54 | 1399 | 379 | 3.91 / 322.86 | 5 | 125 |
7 | 13 | 190.80 | 20 | 13.97 | 622 | 174 | 4.09 / 323.03 | 5 | 119 |
8 | 8 | 0.08 | 150 | 13.95 | 359 | 751 | 4.84 / 323.78 | 5 | 129 |
9 | 14 | 0.00 | 50 | 13.73 | 351 | 241 | 5.08 / 324.02 | 5 | 125 |
Average= | 5.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.32 | 29 | 14.14 | 518 | 212 | 0.21 / 313.92 | 5 | 93 |
2 | 7 | 2002.48 | 41 | 11.34 | 3029 | 1408 | 1.62 / 315.33 | 93 | 71 |
3 | 13 | 1917.56 | 20 | 12.66 | 2954 | 748 | 2.37 / 316.08 | 5 | 88 |
4 | 13 | 1721.08 | 20 | 12.94 | 2677 | 693 | 3.06 / 316.77 | 5 | 98 |
5 | 13 | 1178.96 | 20 | 13.28 | 1989 | 528 | 3.59 / 317.30 | 5 | 115 |
6 | 13 | 733.76 | 20 | 13.57 | 1375 | 373 | 3.96 / 317.67 | 5 | 126 |
7 | 13 | 7.44 | 20 | 14.16 | 364 | 103 | 4.07 / 317.77 | 5 | 114 |
8 | 8 | 0.28 | 241 | 13.84 | 350 | 1167 | 5.23 / 318.94 | 5 | 129 |
Average= | 5.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.52 | 28 | 14.15 | 507 | 201 | 0.20 / 308.58 | 5 | 102 |
2 | 3 | 1020.96 | 1 | 12.52 | 1814 | 23 | 0.22 / 308.60 | 5 | 6 |
3 | 7 | 2016.32 | 40 | 11.42 | 3046 | 1391 | 1.61 / 309.99 | 6 | 73 |
4 | 13 | 1946.96 | 20 | 12.68 | 2988 | 758 | 2.37 / 310.75 | 5 | 90 |
5 | 13 | 1526.68 | 20 | 13.08 | 2444 | 639 | 3.01 / 311.39 | 5 | 105 |
6 | 13 | 1204.28 | 20 | 13.29 | 2016 | 536 | 3.55 / 311.93 | 5 | 117 |
7 | 13 | 552.28 | 20 | 13.68 | 1124 | 308 | 3.86 / 312.23 | 5 | 129 |
8 | 13 | 238.44 | 20 | 13.95 | 674 | 188 | 4.04 / 312.42 | 5 | 121 |
9 | 13 | 3.40 | 20 | 14.15 | 366 | 104 | 4.15 / 312.52 | 5 | 114 |
10 | 8 | -0.16 | 242 | 13.82 | 354 | 1184 | 5.33 / 313.71 | 5 | 133 |
Average= | 5.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.12 | 28 | 14.16 | 506 | 201 | 0.20 / 303.27 | 5 | 101 |
2 | 7 | 2005.00 | 40 | 11.50 | 3044 | 1400 | 1.60 / 304.67 | 5 | 73 |
3 | 13 | 1932.08 | 20 | 12.72 | 2953 | 751 | 2.35 / 305.42 | 5 | 90 |
4 | 13 | 1839.44 | 20 | 12.84 | 2833 | 728 | 3.08 / 306.15 | 5 | 96 |
5 | 13 | 1085.80 | 20 | 13.35 | 1842 | 492 | 3.57 / 306.64 | 5 | 118 |
6 | 13 | 992.72 | 20 | 13.39 | 1728 | 463 | 4.03 / 307.10 | 5 | 121 |
7 | 13 | 170.16 | 20 | 13.99 | 599 | 168 | 4.20 / 307.27 | 5 | 124 |
8 | 13 | 39.04 | 20 | 14.12 | 415 | 117 | 4.32 / 307.39 | 5 | 112 |
9 | 8 | 0.12 | 88 | 14.01 | 361 | 445 | 4.76 / 307.83 | 5 | 135 |
10 | 14 | 0.04 | 112 | 13.77 | 354 | 546 | 5.31 / 308.38 | 5 | 109 |
Average= | 5.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.32 | 27 | 14.21 | 504 | 193 | 0.19 / 298.11 | 5 | 98 |
2 | 3 | 1044.28 | 1 | 13.57 | 1854 | 25 | 0.22 / 298.14 | 5 | 35 |
3 | 7 | 2010.52 | 41 | 11.57 | 3051 | 1447 | 1.67 / 299.59 | 35 | 73 |
4 | 13 | 1936.64 | 20 | 12.73 | 2961 | 754 | 2.42 / 300.34 | 5 | 89 |
5 | 13 | 1622.04 | 20 | 13.05 | 2572 | 671 | 3.09 / 301.01 | 5 | 102 |
6 | 13 | 1198.00 | 20 | 13.31 | 2013 | 536 | 3.63 / 301.55 | 5 | 115 |
7 | 13 | 782.48 | 20 | 13.56 | 1450 | 393 | 4.02 / 301.94 | 5 | 126 |
8 | 13 | 105.28 | 20 | 14.06 | 500 | 141 | 4.16 / 302.08 | 5 | 110 |
9 | 8 | -0.08 | 194 | 13.92 | 354 | 956 | 5.12 / 303.04 | 5 | 130 |
10 | 14 | -0.12 | 6 | 13.74 | 359 | 30 | 5.15 / 303.07 | 7 | 123 |
Average= | 5.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.52 | 29 | 14.21 | 499 | 206 | 0.21 / 292.90 | 5 | 97 |
2 | 3 | 967.56 | -1 | 14.21 | 499 | 0 | 0.00 / 292.90 | 5 | 97 |
3 | 7 | 2007.32 | 41 | 11.63 | 3041 | 1450 | 1.66 / 294.35 | 97 | 69 |
4 | 13 | 1931.28 | 20 | 12.74 | 2962 | 755 | 2.41 / 295.10 | 5 | 88 |
5 | 13 | 1618.64 | 20 | 13.07 | 2557 | 668 | 3.08 / 295.77 | 5 | 99 |
6 | 13 | 1093.40 | 20 | 13.38 | 1869 | 500 | 3.58 / 296.27 | 5 | 117 |
7 | 13 | 995.40 | 20 | 13.41 | 1745 | 468 | 4.05 / 296.74 | 5 | 121 |
8 | 13 | 275.88 | 20 | 13.92 | 733 | 204 | 4.25 / 296.94 | 5 | 122 |
9 | 8 | 0.04 | 167 | 13.96 | 352 | 821 | 5.07 / 297.76 | 5 | 129 |
10 | 14 | 0.00 | 33 | 13.77 | 349 | 159 | 5.23 / 297.92 | 8 | 129 |
Average= | 5.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.28 | 28 | 14.21 | 511 | 203 | 0.20 / 287.64 | 5 | 96 |
2 | 3 | 1027.44 | 1 | 13.25 | 1812 | 24 | 0.23 / 287.66 | 5 | 9 |
3 | 7 | 2006.36 | 41 | 11.73 | 3035 | 1460 | 1.69 / 289.12 | 9 | 75 |
4 | 13 | 1930.32 | 20 | 12.76 | 2959 | 755 | 2.44 / 289.87 | 5 | 90 |
5 | 13 | 1728.76 | 20 | 13.02 | 2695 | 702 | 3.14 / 290.58 | 5 | 99 |
6 | 13 | 1203.24 | 20 | 13.32 | 2020 | 538 | 3.68 / 291.11 | 5 | 117 |
7 | 13 | 553.76 | 20 | 13.73 | 1120 | 308 | 3.99 / 291.42 | 5 | 128 |
8 | 13 | 57.20 | 20 | 14.14 | 431 | 122 | 4.11 / 291.54 | 5 | 116 |
9 | 8 | 0.08 | 238 | 13.89 | 347 | 1147 | 5.26 / 292.69 | 5 | 135 |
Average= | 5.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.52 | 28 | 14.22 | 501 | 199 | 0.20 / 282.74 | 5 | 94 |
2 | 7 | 2000.92 | 40 | 11.76 | 3016 | 1419 | 1.62 / 284.16 | 94 | 75 |
3 | 13 | 1806.32 | 20 | 12.94 | 2798 | 724 | 2.34 / 284.88 | 5 | 94 |
4 | 13 | 1713.36 | 20 | 12.98 | 2676 | 695 | 3.04 / 285.58 | 5 | 99 |
5 | 13 | 1175.96 | 20 | 13.35 | 1989 | 531 | 3.57 / 286.11 | 5 | 115 |
6 | 13 | 643.56 | 20 | 13.68 | 1249 | 342 | 3.91 / 286.45 | 5 | 125 |
7 | 8 | -0.16 | 6 | 14.14 | 365 | 31 | 3.94 / 286.48 | 5 | 136 |
8 | 14 | 0.04 | 194 | 13.94 | 352 | 952 | 4.89 / 287.43 | 5 | 121 |
Average= | 5.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.12 | 27 | 14.24 | 514 | 198 | 0.20 / 277.40 | 5 | 93 |
2 | 3 | 1046.96 | 1 | 13.63 | 1855 | 25 | 0.22 / 277.43 | 5 | 36 |
3 | 7 | 2006.36 | 40 | 11.83 | 3045 | 1441 | 1.66 / 278.87 | 36 | 75 |
4 | 13 | 1922.52 | 20 | 12.81 | 2930 | 751 | 2.41 / 279.62 | 5 | 90 |
5 | 13 | 1730.08 | 20 | 13.05 | 2699 | 704 | 3.12 / 280.33 | 5 | 99 |
6 | 13 | 1172.12 | 20 | 13.38 | 1961 | 525 | 3.64 / 280.85 | 5 | 115 |
7 | 13 | 840.12 | 20 | 13.57 | 1523 | 413 | 4.06 / 281.26 | 5 | 126 |
8 | 13 | 243.28 | 20 | 13.97 | 684 | 191 | 4.25 / 281.45 | 5 | 123 |
9 | 13 | 19.76 | 20 | 14.18 | 382 | 108 | 4.36 / 281.56 | 5 | 113 |
10 | 8 | 0.32 | 170 | 13.95 | 351 | 832 | 5.19 / 282.40 | 5 | 135 |
11 | 14 | 0.28 | 30 | 13.78 | 348 | 144 | 5.33 / 282.54 | 11 | 121 |
Average= | 5.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.48 | 27 | 14.25 | 500 | 192 | 0.19 / 272.22 | 5 | 83 |
2 | 7 | 2005.24 | 41 | 11.88 | 3035 | 1478 | 1.67 / 273.70 | 5 | 76 |
3 | 13 | 1914.04 | 20 | 12.84 | 2942 | 756 | 2.43 / 274.45 | 5 | 90 |
4 | 13 | 1706.60 | 20 | 13.09 | 2665 | 698 | 3.12 / 275.15 | 5 | 99 |
5 | 13 | 1270.20 | 20 | 13.33 | 2111 | 563 | 3.69 / 275.71 | 5 | 113 |
6 | 13 | 816.00 | 20 | 13.59 | 1482 | 403 | 4.09 / 276.12 | 5 | 124 |
7 | 13 | 27.60 | 20 | 14.18 | 392 | 111 | 4.20 / 276.23 | 5 | 116 |
8 | 8 | -0.04 | 179 | 13.95 | 352 | 879 | 5.08 / 277.11 | 5 | 129 |
9 | 14 | -0.32 | 21 | 13.79 | 350 | 101 | 5.18 / 277.21 | 10 | 125 |
Average= | 5.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.72 | 26 | 14.24 | 496 | 184 | 0.18 / 266.77 | 5 | 90 |
2 | 3 | 1045.64 | 1 | 13.73 | 1846 | 25 | 0.21 / 266.80 | 5 | 36 |
3 | 7 | 2005.60 | 41 | 12.00 | 3040 | 1496 | 1.70 / 268.29 | 36 | 77 |
4 | 13 | 1913.40 | 20 | 12.86 | 2934 | 755 | 2.46 / 269.05 | 5 | 90 |
5 | 13 | 1701.28 | 20 | 13.09 | 2656 | 695 | 3.15 / 269.74 | 5 | 99 |
6 | 13 | 1147.88 | 20 | 13.41 | 1939 | 520 | 3.67 / 270.26 | 5 | 117 |
7 | 13 | 607.80 | 20 | 13.75 | 1193 | 328 | 4.00 / 270.59 | 5 | 126 |
8 | 13 | 40.56 | 20 | 14.18 | 407 | 115 | 4.12 / 270.70 | 5 | 122 |
9 | 8 | 0.00 | 275 | 13.89 | 346 | 1322 | 5.44 / 272.03 | 6 | 134 |
Average= | 5.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.28 | 28 | 14.30 | 491 | 197 | 0.20 / 261.83 | 5 | 84 |
2 | 3 | 944.60 | -1 | 14.30 | 491 | 0 | 0.00 / 261.83 | 5 | 84 |
3 | 7 | 2008.12 | 41 | 12.02 | 3041 | 1499 | 1.70 / 263.33 | 84 | 77 |
4 | 13 | 1924.48 | 20 | 12.87 | 2930 | 754 | 2.45 / 264.08 | 5 | 90 |
5 | 13 | 1615.76 | 20 | 13.17 | 2541 | 669 | 3.12 / 264.75 | 5 | 101 |
6 | 13 | 1185.68 | 20 | 13.42 | 2002 | 537 | 3.66 / 265.29 | 5 | 117 |
7 | 13 | 635.68 | 20 | 13.74 | 1228 | 337 | 3.99 / 265.62 | 5 | 123 |
8 | 8 | 0.24 | 6 | 14.20 | 350 | 30 | 4.02 / 265.65 | 5 | 129 |
9 | 14 | 0.32 | 194 | 14.00 | 343 | 932 | 4.95 / 266.59 | 5 | 123 |
Average= | 5.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.08 | 28 | 14.27 | 503 | 201 | 0.20 / 256.04 | 5 | 87 |
2 | 7 | 2001.36 | 40 | 12.12 | 3027 | 1467 | 1.67 / 257.51 | 87 | 78 |
3 | 13 | 1908.04 | 20 | 12.90 | 2927 | 755 | 2.42 / 258.26 | 5 | 91 |
4 | 13 | 1706.96 | 20 | 13.13 | 2673 | 702 | 3.13 / 258.97 | 5 | 100 |
5 | 13 | 1041.88 | 20 | 13.49 | 1797 | 485 | 3.61 / 259.45 | 5 | 119 |
6 | 13 | 943.76 | 20 | 13.53 | 1653 | 447 | 4.06 / 259.90 | 5 | 122 |
7 | 13 | 131.20 | 20 | 14.12 | 525 | 148 | 4.21 / 260.05 | 5 | 115 |
8 | 13 | 23.12 | 20 | 14.21 | 380 | 108 | 4.31 / 260.16 | 5 | 121 |
9 | 8 | 0.16 | 316 | 13.90 | 336 | 1476 | 5.79 / 261.63 | 5 | 129 |
Average= | 5.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.92 | 28 | 14.30 | 507 | 203 | 0.20 / 250.96 | 5 | 79 |
2 | 7 | 2008.84 | 40 | 12.17 | 3044 | 1482 | 1.68 / 252.44 | 79 | 79 |
3 | 13 | 1922.40 | 20 | 12.91 | 2955 | 763 | 2.45 / 253.20 | 5 | 91 |
4 | 13 | 1605.76 | 20 | 13.19 | 2537 | 669 | 3.12 / 253.87 | 5 | 103 |
5 | 13 | 1271.56 | 20 | 13.39 | 2109 | 565 | 3.68 / 254.43 | 5 | 114 |
6 | 13 | 611.44 | 20 | 13.76 | 1203 | 331 | 4.01 / 254.77 | 5 | 126 |
7 | 13 | 43.88 | 20 | 14.21 | 407 | 116 | 4.13 / 254.88 | 5 | 119 |
8 | 8 | -0.04 | 154 | 14.03 | 344 | 743 | 4.87 / 255.62 | 5 | 134 |
9 | 14 | -0.08 | 46 | 13.88 | 339 | 216 | 5.09 / 255.84 | 8 | 120 |
Average= | 5.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.80 | 27 | 14.33 | 500 | 193 | 0.19 / 245.41 | 5 | 85 |
2 | 7 | 2008.64 | 40 | 12.29 | 3050 | 1499 | 1.69 / 246.91 | 5 | 77 |
3 | 13 | 1923.88 | 20 | 12.94 | 2953 | 764 | 2.46 / 247.67 | 5 | 89 |
4 | 13 | 1614.08 | 20 | 13.21 | 2538 | 671 | 3.13 / 248.34 | 5 | 100 |
5 | 13 | 1165.80 | 20 | 13.45 | 1974 | 531 | 3.66 / 248.87 | 5 | 115 |
6 | 13 | 705.36 | 20 | 13.72 | 1325 | 364 | 4.02 / 249.23 | 5 | 123 |
7 | 13 | 67.04 | 20 | 14.19 | 442 | 125 | 4.15 / 249.36 | 5 | 115 |
8 | 8 | 0.04 | 292 | 13.95 | 342 | 1393 | 5.54 / 250.75 | 5 | 137 |
Average= | 5.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.76 | 27 | 14.33 | 495 | 192 | 0.19 / 240.10 | 5 | 86 |
2 | 7 | 2007.16 | 40 | 12.31 | 3040 | 1497 | 1.69 / 241.60 | 86 | 84 |
3 | 13 | 1914.00 | 20 | 12.95 | 2937 | 761 | 2.45 / 242.36 | 5 | 95 |
4 | 13 | 1608.96 | 20 | 13.23 | 2545 | 673 | 3.12 / 243.03 | 5 | 103 |
5 | 13 | 1168.64 | 20 | 13.47 | 1954 | 526 | 3.65 / 243.56 | 5 | 113 |
6 | 13 | 614.00 | 20 | 13.78 | 1203 | 332 | 3.98 / 243.89 | 5 | 125 |
7 | 13 | 74.88 | 20 | 14.20 | 449 | 128 | 4.11 / 244.02 | 5 | 106 |
8 | 8 | -0.08 | 252 | 13.99 | 339 | 1195 | 5.30 / 245.21 | 5 | 129 |
Average= | 5.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.20 | 27 | 14.32 | 493 | 191 | 0.19 / 234.87 | 5 | 85 |
2 | 7 | 2005.20 | 40 | 12.33 | 3041 | 1500 | 1.69 / 236.37 | 5 | 80 |
3 | 13 | 1911.12 | 20 | 12.96 | 2929 | 759 | 2.45 / 237.13 | 5 | 92 |
4 | 13 | 1498.64 | 20 | 13.30 | 2395 | 637 | 3.09 / 237.76 | 5 | 106 |
5 | 13 | 1062.44 | 20 | 13.52 | 1827 | 494 | 3.58 / 238.26 | 5 | 119 |
6 | 13 | 538.16 | 20 | 13.85 | 1086 | 301 | 3.88 / 238.56 | 5 | 123 |
7 | 13 | 42.48 | 20 | 14.23 | 408 | 116 | 4.00 / 238.68 | 5 | 122 |
8 | 8 | -0.04 | 259 | 13.97 | 341 | 1234 | 5.23 / 239.91 | 5 | 131 |
Average= | 5.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.60 | 29 | 14.34 | 504 | 210 | 0.21 / 229.87 | 5 | 78 |
2 | 3 | 928.20 | -1 | 14.34 | 504 | 0 | 0.00 / 229.87 | 5 | 78 |
3 | 7 | 2001.88 | 40 | 12.37 | 3038 | 1503 | 1.71 / 231.37 | 78 | 81 |
4 | 13 | 1910.92 | 20 | 12.96 | 2942 | 763 | 2.48 / 232.13 | 5 | 92 |
5 | 13 | 1596.44 | 20 | 13.25 | 2524 | 669 | 3.14 / 232.80 | 5 | 103 |
6 | 13 | 1062.36 | 20 | 13.53 | 1832 | 496 | 3.64 / 233.30 | 5 | 119 |
7 | 13 | 522.08 | 20 | 13.86 | 1068 | 296 | 3.94 / 233.60 | 5 | 125 |
8 | 13 | 41.56 | 20 | 14.24 | 407 | 116 | 4.05 / 233.71 | 5 | 122 |
9 | 8 | 0.08 | 6 | 14.24 | 357 | 31 | 4.08 / 233.74 | 5 | 131 |
10 | 14 | 0.16 | 194 | 14.02 | 344 | 936 | 5.02 / 234.68 | 5 | 117 |
Average= | 4.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.96 | 26 | 14.36 | 503 | 188 | 0.19 / 224.22 | 5 | 80 |
2 | 10 | 1033.84 | 3 | 14.08 | 1836 | 78 | 0.27 / 224.30 | 5 | 83 |
3 | 7 | 2008.12 | 40 | 12.38 | 3040 | 1505 | 1.77 / 225.80 | 5 | 81 |
4 | 13 | 1925.56 | 20 | 12.96 | 2954 | 766 | 2.54 / 226.57 | 5 | 92 |
5 | 13 | 1516.12 | 20 | 13.30 | 2424 | 645 | 3.18 / 227.22 | 5 | 106 |
6 | 13 | 1196.92 | 20 | 13.47 | 1999 | 539 | 3.72 / 227.75 | 5 | 116 |
7 | 13 | 539.20 | 20 | 13.86 | 1090 | 302 | 4.02 / 228.06 | 5 | 125 |
8 | 13 | 45.96 | 20 | 14.25 | 412 | 117 | 4.14 / 228.17 | 5 | 118 |
9 | 13 | 4.32 | 20 | 14.24 | 356 | 101 | 4.24 / 228.27 | 5 | 117 |
10 | 8 | 0.08 | 292 | 13.95 | 340 | 1385 | 5.63 / 229.66 | 5 | 132 |
Average= | 4.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.40 | 27 | 14.36 | 489 | 190 | 0.19 / 219.22 | 5 | 78 |
2 | 3 | 950.76 | -1 | 14.36 | 489 | 0 | 0.00 / 219.22 | 5 | 78 |
3 | 7 | 2004.00 | 41 | 12.36 | 3031 | 1536 | 1.73 / 220.76 | 78 | 80 |
4 | 13 | 1915.84 | 20 | 12.94 | 2946 | 762 | 2.49 / 221.52 | 5 | 92 |
5 | 13 | 1493.08 | 20 | 13.29 | 2405 | 639 | 3.13 / 222.16 | 5 | 106 |
6 | 13 | 978.72 | 20 | 13.58 | 1704 | 463 | 3.59 / 222.63 | 5 | 120 |
7 | 13 | 652.92 | 20 | 13.80 | 1239 | 342 | 3.93 / 222.97 | 5 | 126 |
8 | 13 | 19.64 | 20 | 14.28 | 375 | 107 | 4.04 / 223.07 | 5 | 113 |
9 | 8 | -0.16 | 176 | 14.07 | 342 | 847 | 4.89 / 223.92 | 5 | 132 |
10 | 14 | -0.16 | 24 | 13.94 | 337 | 113 | 5.00 / 224.03 | 8 | 116 |
Average= | 4.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.88 | 27 | 14.38 | 503 | 195 | 0.20 / 213.60 | 5 | 83 |
2 | 3 | 1026.48 | 1 | 13.71 | 1797 | 25 | 0.22 / 213.63 | 5 | 10 |
3 | 7 | 2005.36 | 40 | 12.38 | 3026 | 1498 | 1.72 / 215.13 | 10 | 85 |
4 | 13 | 1923.92 | 20 | 12.96 | 2927 | 759 | 2.48 / 215.89 | 5 | 94 |
5 | 13 | 1616.12 | 20 | 13.24 | 2549 | 675 | 3.15 / 216.56 | 5 | 104 |
6 | 13 | 1183.00 | 20 | 13.47 | 1990 | 536 | 3.69 / 217.10 | 5 | 115 |
7 | 13 | 622.16 | 20 | 13.81 | 1205 | 333 | 4.02 / 217.43 | 5 | 121 |
8 | 13 | 36.44 | 20 | 14.28 | 396 | 113 | 4.13 / 217.54 | 5 | 115 |
9 | 8 | -0.24 | 314 | 13.98 | 340 | 1493 | 5.63 / 219.04 | 5 | 132 |
Average= | 4.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.00 | 26 | 14.38 | 487 | 182 | 0.18 / 208.32 | 5 | 85 |
2 | 7 | 2007.96 | 41 | 12.36 | 3035 | 1538 | 1.72 / 209.86 | 5 | 84 |
3 | 13 | 1916.68 | 20 | 12.94 | 2944 | 762 | 2.48 / 210.62 | 5 | 94 |
4 | 13 | 1498.80 | 20 | 13.28 | 2398 | 637 | 3.12 / 211.26 | 5 | 108 |
5 | 13 | 1077.88 | 20 | 13.54 | 1847 | 500 | 3.62 / 211.76 | 5 | 117 |
6 | 13 | 640.40 | 20 | 13.82 | 1221 | 337 | 3.96 / 212.10 | 5 | 124 |
7 | 13 | 3.64 | 20 | 14.33 | 346 | 99 | 4.06 / 212.20 | 5 | 114 |
8 | 8 | 0.16 | 256 | 14.04 | 337 | 1211 | 5.27 / 213.41 | 5 | 133 |
Average= | 4.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.68 | 26 | 14.39 | 501 | 187 | 0.19 / 203.15 | 5 | 82 |
2 | 7 | 2003.28 | 40 | 12.31 | 3039 | 1496 | 1.68 / 204.65 | 82 | 82 |
3 | 13 | 1912.68 | 20 | 12.93 | 2924 | 756 | 2.44 / 205.41 | 5 | 92 |
4 | 13 | 1601.64 | 20 | 13.23 | 2524 | 668 | 3.11 / 206.07 | 5 | 103 |
5 | 13 | 1063.92 | 20 | 13.55 | 1823 | 494 | 3.60 / 206.57 | 5 | 119 |
6 | 13 | 435.28 | 20 | 13.97 | 914 | 255 | 3.86 / 206.82 | 5 | 117 |
7 | 8 | 0.12 | 279 | 14.06 | 336 | 1318 | 5.18 / 208.14 | 5 | 131 |
Average= | 4.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.48 | 28 | 14.37 | 488 | 196 | 0.20 / 197.59 | 5 | 80 |
2 | 3 | 931.76 | -1 | 14.37 | 488 | 0 | 0.00 / 197.59 | 5 | 80 |
3 | 7 | 2007.96 | 40 | 12.35 | 3040 | 1502 | 1.70 / 199.09 | 80 | 82 |
4 | 13 | 1913.96 | 20 | 12.96 | 2948 | 764 | 2.46 / 199.85 | 5 | 92 |
5 | 13 | 1598.84 | 20 | 13.25 | 2530 | 670 | 3.13 / 200.52 | 5 | 103 |
6 | 13 | 1060.48 | 20 | 13.56 | 1812 | 491 | 3.62 / 201.01 | 5 | 118 |
7 | 13 | 523.48 | 20 | 13.92 | 1069 | 298 | 3.92 / 201.31 | 5 | 125 |
8 | 8 | 0.08 | 349 | 14.02 | 338 | 1654 | 5.58 / 202.97 | 5 | 129 |
Average= | 4.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.28 | 27 | 14.40 | 497 | 193 | 0.19 / 191.96 | 5 | 87 |
2 | 3 | 1056.60 | 1 | 13.96 | 1875 | 26 | 0.22 / 191.98 | 5 | 51 |
3 | 7 | 2007.68 | 41 | 12.44 | 3045 | 1553 | 1.77 / 193.54 | 51 | 83 |
4 | 13 | 1920.32 | 20 | 12.99 | 2941 | 764 | 2.54 / 194.30 | 5 | 93 |
5 | 13 | 1602.60 | 20 | 13.27 | 2543 | 675 | 3.21 / 194.97 | 5 | 105 |
6 | 13 | 1062.04 | 20 | 13.58 | 1828 | 496 | 3.71 / 195.47 | 5 | 121 |
7 | 13 | 614.16 | 20 | 13.87 | 1194 | 331 | 4.04 / 195.80 | 5 | 125 |
8 | 8 | 0.00 | 336 | 14.03 | 337 | 1589 | 5.63 / 197.39 | 5 | 129 |
Average= | 4.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.28 | 26 | 14.39 | 503 | 188 | 0.19 / 187.08 | 5 | 86 |
2 | 3 | 1043.20 | 1 | 13.96 | 1814 | 25 | 0.21 / 187.10 | 5 | 36 |
3 | 7 | 2003.72 | 40 | 12.48 | 3046 | 1521 | 1.73 / 188.62 | 36 | 79 |
4 | 13 | 1919.12 | 20 | 13.00 | 2957 | 769 | 2.50 / 189.39 | 5 | 90 |
5 | 13 | 1508.00 | 20 | 13.34 | 2422 | 646 | 3.15 / 190.04 | 5 | 105 |
6 | 13 | 1079.60 | 20 | 13.58 | 1850 | 502 | 3.65 / 190.54 | 5 | 118 |
7 | 13 | 427.40 | 20 | 14.02 | 925 | 259 | 3.91 / 190.80 | 5 | 116 |
8 | 8 | 0.00 | 177 | 14.17 | 341 | 855 | 4.77 / 191.65 | 5 | 130 |
9 | 14 | -0.16 | 23 | 14.00 | 338 | 109 | 4.88 / 191.76 | 10 | 113 |
Average= | 4.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.72 | 27 | 14.40 | 501 | 195 | 0.19 / 181.68 | 5 | 87 |
2 | 3 | 946.72 | -1 | 14.40 | 501 | 0 | 0.00 / 181.68 | 5 | 87 |
3 | 7 | 2002.92 | 41 | 12.53 | 3017 | 1550 | 1.74 / 183.23 | 87 | 82 |
4 | 13 | 1915.20 | 20 | 13.02 | 2928 | 762 | 2.51 / 184.00 | 5 | 92 |
5 | 13 | 1615.32 | 20 | 13.29 | 2555 | 679 | 3.19 / 184.67 | 5 | 104 |
6 | 13 | 1173.08 | 20 | 13.54 | 1969 | 533 | 3.72 / 185.21 | 5 | 117 |
7 | 13 | 409.40 | 20 | 14.02 | 916 | 257 | 3.98 / 185.46 | 5 | 125 |
8 | 8 | 0.00 | 299 | 14.08 | 338 | 1423 | 5.40 / 186.89 | 5 | 129 |
Average= | 4.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.40 | 29 | 14.40 | 503 | 210 | 0.21 / 176.18 | 5 | 86 |
2 | 3 | 909.64 | -1 | 14.40 | 503 | 0 | 0.00 / 176.18 | 5 | 86 |
3 | 7 | 2008.52 | 40 | 12.58 | 3035 | 1527 | 1.74 / 177.71 | 86 | 82 |
4 | 13 | 1912.56 | 20 | 13.05 | 2931 | 765 | 2.50 / 178.48 | 5 | 93 |
5 | 13 | 1588.88 | 20 | 13.33 | 2519 | 672 | 3.17 / 179.15 | 5 | 105 |
6 | 13 | 1060.40 | 20 | 13.62 | 1826 | 497 | 3.67 / 179.65 | 5 | 120 |
7 | 13 | 520.48 | 20 | 13.97 | 1065 | 298 | 3.97 / 179.94 | 5 | 127 |
8 | 8 | 0.32 | 326 | 14.07 | 337 | 1546 | 5.51 / 181.49 | 6 | 134 |
Average= | 4.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.52 | 26 | 14.42 | 511 | 192 | 0.19 / 170.61 | 5 | 85 |
2 | 10 | 1024.16 | 3 | 14.19 | 1818 | 77 | 0.27 / 170.69 | 5 | 82 |
3 | 7 | 2004.88 | 41 | 12.62 | 3035 | 1570 | 1.84 / 172.26 | 82 | 84 |
4 | 13 | 1918.84 | 20 | 13.09 | 2942 | 770 | 2.61 / 173.03 | 5 | 93 |
5 | 13 | 1413.68 | 20 | 13.43 | 2298 | 617 | 3.23 / 173.65 | 5 | 109 |
6 | 13 | 990.24 | 20 | 13.69 | 1721 | 471 | 3.70 / 174.12 | 5 | 121 |
7 | 13 | 454.24 | 20 | 14.05 | 953 | 268 | 3.97 / 174.39 | 5 | 121 |
8 | 8 | -0.12 | 331 | 14.07 | 341 | 1588 | 5.55 / 175.97 | 5 | 131 |
Average= | 4.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.12 | 28 | 14.44 | 500 | 202 | 0.20 / 165.73 | 5 | 84 |
2 | 3 | 951.16 | -1 | 14.44 | 500 | 0 | 0.00 / 165.73 | 5 | 84 |
3 | 7 | 2002.44 | 40 | 12.66 | 3034 | 1536 | 1.74 / 167.27 | 84 | 87 |
4 | 13 | 1908.72 | 20 | 13.08 | 2924 | 765 | 2.50 / 168.03 | 5 | 95 |
5 | 13 | 1401.80 | 20 | 13.45 | 2273 | 611 | 3.11 / 168.64 | 5 | 108 |
6 | 13 | 973.80 | 20 | 13.70 | 1705 | 467 | 3.58 / 169.11 | 5 | 121 |
7 | 13 | 327.32 | 20 | 14.13 | 801 | 226 | 3.81 / 169.34 | 5 | 119 |
8 | 13 | 21.16 | 20 | 14.40 | 378 | 109 | 3.92 / 169.44 | 5 | 121 |
9 | 8 | -0.16 | 164 | 14.16 | 346 | 803 | 4.72 / 170.25 | 5 | 131 |
10 | 14 | -0.12 | 36 | 14.01 | 342 | 172 | 4.89 / 170.42 | 10 | 118 |
Average= | 4.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.52 | 27 | 14.44 | 501 | 195 | 0.20 / 160.07 | 5 | 87 |
2 | 3 | 1022.36 | 1 | 13.96 | 1812 | 25 | 0.22 / 160.09 | 5 | 8 |
3 | 7 | 2002.52 | 41 | 12.68 | 3037 | 1579 | 1.80 / 161.67 | 8 | 86 |
4 | 13 | 1912.12 | 20 | 13.08 | 2942 | 770 | 2.57 / 162.44 | 5 | 96 |
5 | 13 | 1501.68 | 20 | 13.39 | 2411 | 646 | 3.21 / 163.09 | 5 | 110 |
6 | 13 | 1070.32 | 20 | 13.65 | 1835 | 501 | 3.72 / 163.59 | 5 | 122 |
7 | 13 | 324.64 | 20 | 14.15 | 780 | 221 | 3.94 / 163.81 | 5 | 116 |
8 | 8 | 0.12 | 361 | 14.07 | 338 | 1717 | 5.65 / 165.53 | 5 | 134 |
Average= | 4.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.84 | 27 | 14.45 | 509 | 199 | 0.20 / 155.11 | 5 | 83 |
2 | 7 | 2002.92 | 40 | 12.73 | 3037 | 1546 | 1.75 / 156.66 | 83 | 86 |
3 | 13 | 1909.76 | 20 | 13.13 | 2924 | 768 | 2.51 / 157.43 | 5 | 95 |
4 | 13 | 1595.36 | 20 | 13.38 | 2521 | 675 | 3.19 / 158.10 | 5 | 105 |
5 | 13 | 1149.88 | 20 | 13.62 | 1947 | 530 | 3.72 / 158.63 | 5 | 119 |
6 | 13 | 470.92 | 20 | 14.05 | 999 | 281 | 4.00 / 158.91 | 5 | 126 |
7 | 8 | 0.08 | 141 | 14.25 | 339 | 681 | 4.68 / 159.59 | 5 | 135 |
8 | 14 | 0.04 | 59 | 14.06 | 336 | 279 | 4.96 / 159.87 | 5 | 121 |
Average= | 4.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.92 | 27 | 14.46 | 507 | 198 | 0.20 / 149.72 | 5 | 82 |
2 | 7 | 2002.40 | 41 | 12.75 | 3049 | 1594 | 1.79 / 151.31 | 82 | 86 |
3 | 13 | 1912.16 | 20 | 13.12 | 2939 | 771 | 2.56 / 152.08 | 5 | 96 |
4 | 13 | 1495.52 | 20 | 13.45 | 2404 | 647 | 3.21 / 152.73 | 5 | 109 |
5 | 13 | 961.88 | 20 | 13.74 | 1689 | 464 | 3.67 / 153.19 | 5 | 123 |
6 | 13 | 319.16 | 20 | 14.19 | 758 | 215 | 3.89 / 153.41 | 5 | 115 |
7 | 13 | 1.12 | 20 | 14.47 | 347 | 100 | 3.99 / 153.51 | 5 | 124 |
8 | 8 | -0.04 | 298 | 14.10 | 335 | 1408 | 5.40 / 154.92 | 5 | 134 |
Average= | 4.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.24 | 27 | 14.48 | 500 | 195 | 0.20 / 144.25 | 5 | 84 |
2 | 7 | 2008.64 | 41 | 12.78 | 3047 | 1597 | 1.79 / 145.85 | 84 | 87 |
3 | 13 | 1914.80 | 20 | 13.13 | 2943 | 773 | 2.56 / 146.62 | 5 | 96 |
4 | 13 | 1506.36 | 20 | 13.45 | 2423 | 652 | 3.22 / 147.28 | 5 | 105 |
5 | 13 | 1072.68 | 20 | 13.69 | 1842 | 504 | 3.72 / 147.78 | 5 | 118 |
6 | 13 | 322.76 | 20 | 14.20 | 770 | 219 | 3.94 / 148.00 | 5 | 109 |
7 | 13 | 3.72 | 20 | 14.48 | 348 | 101 | 4.04 / 148.10 | 5 | 111 |
8 | 8 | -0.12 | 298 | 14.13 | 337 | 1419 | 5.46 / 149.52 | 5 | 132 |
Average= | 4.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.36 | 26 | 14.50 | 497 | 187 | 0.19 / 138.53 | 5 | 82 |
2 | 3 | 1044.36 | 1 | 14.20 | 1871 | 27 | 0.21 / 138.56 | 5 | 40 |
3 | 7 | 2003.12 | 41 | 12.78 | 3045 | 1596 | 1.81 / 140.15 | 40 | 88 |
4 | 13 | 1906.44 | 20 | 13.16 | 2926 | 770 | 2.58 / 140.92 | 5 | 96 |
5 | 13 | 1491.80 | 20 | 13.46 | 2400 | 646 | 3.23 / 141.57 | 5 | 109 |
6 | 13 | 1059.00 | 20 | 13.71 | 1826 | 501 | 3.73 / 142.07 | 5 | 120 |
7 | 13 | 598.88 | 20 | 14.01 | 1158 | 324 | 4.05 / 142.39 | 5 | 118 |
8 | 8 | 0.20 | 355 | 14.14 | 332 | 1667 | 5.72 / 144.06 | 5 | 130 |
Average= | 4.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.88 | 28 | 14.51 | 491 | 199 | 0.20 / 133.37 | 5 | 80 |
2 | 3 | 954.04 | -1 | 14.51 | 491 | 0 | 0.00 / 133.37 | 5 | 80 |
3 | 7 | 2001.84 | 41 | 12.81 | 3043 | 1598 | 1.80 / 134.97 | 80 | 85 |
4 | 13 | 1905.28 | 20 | 13.18 | 2927 | 772 | 2.57 / 135.74 | 5 | 94 |
5 | 13 | 1388.36 | 20 | 13.52 | 2270 | 614 | 3.18 / 136.35 | 5 | 111 |
6 | 13 | 982.28 | 20 | 13.76 | 1719 | 473 | 3.66 / 136.83 | 5 | 123 |
7 | 13 | 444.92 | 20 | 14.13 | 943 | 266 | 3.92 / 137.09 | 5 | 118 |
8 | 8 | 0.16 | 261 | 14.18 | 337 | 1247 | 5.17 / 138.34 | 5 | 129 |
Average= | 4.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.44 | 28 | 14.47 | 494 | 200 | 0.20 / 127.89 | 5 | 87 |
2 | 7 | 2003.20 | 41 | 12.81 | 3037 | 1595 | 1.80 / 129.48 | 87 | 85 |
3 | 13 | 1907.28 | 20 | 13.17 | 2938 | 774 | 2.57 / 130.26 | 5 | 96 |
4 | 13 | 1477.08 | 20 | 13.48 | 2394 | 645 | 3.21 / 130.90 | 5 | 110 |
5 | 13 | 935.80 | 20 | 13.79 | 1664 | 459 | 3.67 / 131.36 | 5 | 126 |
6 | 13 | 298.96 | 20 | 14.23 | 754 | 215 | 3.89 / 131.57 | 5 | 116 |
7 | 8 | 0.00 | 337 | 14.15 | 335 | 1597 | 5.49 / 133.17 | 5 | 133 |
Average= | 4.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.24 | 27 | 14.46 | 517 | 202 | 0.20 / 123.04 | 5 | 90 |
2 | 7 | 2003.48 | 40 | 12.82 | 3030 | 1554 | 1.76 / 124.59 | 5 | 85 |
3 | 13 | 1906.88 | 20 | 13.17 | 2938 | 774 | 2.53 / 125.37 | 5 | 95 |
4 | 13 | 1484.60 | 20 | 13.48 | 2393 | 645 | 3.17 / 126.01 | 5 | 108 |
5 | 13 | 861.60 | 20 | 13.84 | 1558 | 431 | 3.61 / 126.45 | 5 | 126 |
6 | 13 | 436.92 | 20 | 14.13 | 964 | 272 | 3.88 / 126.72 | 5 | 126 |
7 | 8 | 0.16 | 8 | 14.54 | 351 | 41 | 3.92 / 126.76 | 5 | 129 |
8 | 14 | 0.12 | 192 | 14.21 | 340 | 928 | 4.85 / 127.69 | 5 | 120 |
Average= | 4.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.48 | 26 | 14.49 | 497 | 187 | 0.19 / 118.00 | 5 | 92 |
2 | 3 | 1042.76 | 1 | 14.27 | 1874 | 27 | 0.21 / 118.03 | 5 | 40 |
3 | 7 | 2001.64 | 41 | 12.84 | 3027 | 1594 | 1.81 / 119.62 | 40 | 88 |
4 | 13 | 1907.88 | 20 | 13.19 | 2925 | 772 | 2.58 / 120.39 | 5 | 95 |
5 | 13 | 1586.84 | 20 | 13.46 | 2513 | 676 | 3.26 / 121.07 | 5 | 107 |
6 | 13 | 1025.36 | 20 | 13.76 | 1775 | 488 | 3.74 / 121.56 | 5 | 122 |
7 | 13 | 486.96 | 20 | 14.10 | 1031 | 291 | 4.03 / 121.85 | 5 | 128 |
8 | 8 | 0.08 | 48 | 14.46 | 354 | 246 | 4.28 / 122.09 | 5 | 135 |
9 | 14 | -0.04 | 152 | 14.13 | 348 | 747 | 5.03 / 122.84 | 5 | 126 |
Average= | 4.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.28 | 26 | 14.45 | 510 | 192 | 0.19 / 113.22 | 5 | 90 |
2 | 7 | 2004.84 | 40 | 12.83 | 3049 | 1565 | 1.76 / 114.78 | 5 | 87 |
3 | 13 | 1718.96 | 20 | 13.35 | 2698 | 720 | 2.48 / 115.50 | 5 | 101 |
4 | 13 | 1625.52 | 20 | 13.37 | 2588 | 692 | 3.17 / 116.19 | 5 | 105 |
5 | 13 | 861.88 | 20 | 13.86 | 1555 | 431 | 3.60 / 116.62 | 5 | 125 |
6 | 13 | 241.96 | 20 | 14.29 | 708 | 202 | 3.80 / 116.83 | 5 | 130 |
7 | 8 | 0.00 | 64 | 14.44 | 350 | 323 | 4.13 / 117.15 | 5 | 131 |
8 | 14 | -0.16 | 136 | 14.13 | 344 | 661 | 4.79 / 117.81 | 6 | 118 |
Average= | 4.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.44 | 28 | 14.45 | 518 | 210 | 0.21 / 108.24 | 5 | 88 |
2 | 3 | 964.96 | -1 | 14.45 | 518 | 0 | 0.00 / 108.24 | 5 | 88 |
3 | 7 | 2002.52 | 40 | 12.83 | 3047 | 1564 | 1.77 / 109.80 | 88 | 88 |
4 | 13 | 1906.76 | 20 | 13.17 | 2938 | 774 | 2.55 / 110.58 | 5 | 97 |
5 | 13 | 1495.16 | 20 | 13.49 | 2419 | 653 | 3.20 / 111.23 | 5 | 110 |
6 | 13 | 1067.28 | 20 | 13.75 | 1829 | 503 | 3.70 / 111.73 | 5 | 122 |
7 | 13 | 505.32 | 20 | 14.09 | 1054 | 297 | 4.00 / 112.03 | 5 | 126 |
8 | 8 | 0.12 | 18 | 14.54 | 356 | 93 | 4.09 / 112.12 | 5 | 133 |
9 | 14 | 0.08 | 182 | 14.18 | 350 | 903 | 5.00 / 113.02 | 5 | 134 |
Average= | 4.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.92 | 28 | 14.45 | 513 | 208 | 0.21 / 103.27 | 5 | 89 |
2 | 7 | 2005.44 | 40 | 12.86 | 3056 | 1572 | 1.78 / 104.84 | 89 | 87 |
3 | 13 | 1914.24 | 20 | 13.19 | 2952 | 779 | 2.56 / 105.62 | 5 | 95 |
4 | 13 | 1407.04 | 20 | 13.54 | 2313 | 626 | 3.18 / 106.24 | 5 | 110 |
5 | 13 | 1083.20 | 20 | 13.74 | 1874 | 515 | 3.70 / 106.76 | 5 | 121 |
6 | 13 | 427.80 | 20 | 14.16 | 961 | 272 | 3.97 / 107.03 | 5 | 128 |
7 | 8 | 0.12 | 61 | 14.46 | 348 | 307 | 4.28 / 107.34 | 5 | 135 |
8 | 14 | -0.08 | 139 | 14.13 | 351 | 689 | 4.97 / 108.03 | 7 | 132 |
Average= | 4.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.32 | 28 | 14.46 | 527 | 213 | 0.21 / 98.28 | 5 | 90 |
2 | 7 | 2004.12 | 40 | 12.85 | 3068 | 1577 | 1.79 / 99.86 | 90 | 87 |
3 | 13 | 1916.88 | 20 | 13.19 | 2965 | 782 | 2.57 / 100.64 | 5 | 96 |
4 | 13 | 1377.24 | 20 | 13.57 | 2265 | 615 | 3.19 / 101.25 | 5 | 113 |
5 | 13 | 960.44 | 20 | 13.81 | 1698 | 469 | 3.66 / 101.72 | 5 | 123 |
6 | 13 | 299.76 | 20 | 14.25 | 781 | 223 | 3.88 / 101.95 | 5 | 124 |
7 | 13 | 6.00 | 20 | 14.51 | 367 | 107 | 3.99 / 102.05 | 5 | 126 |
8 | 8 | 0.24 | 39 | 14.42 | 362 | 204 | 4.19 / 102.26 | 5 | 135 |
9 | 14 | 0.16 | 161 | 14.12 | 354 | 805 | 4.99 / 103.06 | 5 | 139 |
Average= | 4.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.44 | 27 | 14.49 | 517 | 202 | 0.20 / 93.33 | 5 | 81 |
2 | 7 | 2011.04 | 40 | 12.85 | 3060 | 1573 | 1.78 / 94.90 | 5 | 86 |
3 | 13 | 1932.04 | 20 | 13.18 | 2982 | 786 | 2.56 / 95.69 | 5 | 94 |
4 | 13 | 1388.04 | 20 | 13.57 | 2288 | 621 | 3.18 / 96.31 | 5 | 112 |
5 | 13 | 954.36 | 20 | 13.82 | 1694 | 468 | 3.65 / 96.78 | 5 | 123 |
6 | 13 | 417.72 | 20 | 14.17 | 960 | 272 | 3.92 / 97.05 | 5 | 130 |
7 | 8 | 0.00 | 9 | 14.56 | 366 | 48 | 3.97 / 97.10 | 5 | 139 |
8 | 14 | -0.16 | 191 | 14.19 | 358 | 970 | 4.94 / 98.07 | 5 | 138 |
Average= | 4.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.76 | 27 | 14.48 | 503 | 197 | 0.20 / 88.40 | 5 | 82 |
2 | 7 | 2005.24 | 40 | 12.87 | 3045 | 1568 | 1.76 / 89.97 | 82 | 86 |
3 | 13 | 1911.32 | 20 | 13.19 | 2947 | 777 | 2.54 / 90.75 | 5 | 95 |
4 | 13 | 1484.96 | 20 | 13.52 | 2406 | 651 | 3.19 / 91.40 | 5 | 108 |
5 | 13 | 842.64 | 20 | 13.89 | 1546 | 429 | 3.62 / 91.83 | 5 | 125 |
6 | 13 | 429.44 | 20 | 14.16 | 979 | 277 | 3.90 / 92.10 | 5 | 131 |
7 | 8 | -0.12 | 15 | 14.54 | 365 | 80 | 3.98 / 92.18 | 5 | 130 |
8 | 14 | -0.20 | 185 | 14.17 | 360 | 944 | 4.92 / 93.13 | 5 | 130 |
Average= | 4.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.16 | 27 | 14.49 | 508 | 199 | 0.20 / 83.48 | 5 | 78 |
2 | 7 | 2005.92 | 40 | 12.89 | 3034 | 1564 | 1.76 / 85.04 | 78 | 86 |
3 | 13 | 1912.20 | 20 | 13.20 | 2950 | 779 | 2.54 / 85.82 | 5 | 95 |
4 | 13 | 1494.88 | 20 | 13.51 | 2418 | 653 | 3.20 / 86.48 | 5 | 110 |
5 | 13 | 954.92 | 20 | 13.82 | 1699 | 470 | 3.66 / 86.95 | 5 | 124 |
6 | 13 | 335.56 | 20 | 14.21 | 844 | 240 | 3.90 / 87.19 | 5 | 127 |
7 | 8 | -0.12 | 51 | 14.46 | 362 | 267 | 4.17 / 87.45 | 5 | 131 |
8 | 14 | -0.16 | 149 | 14.12 | 357 | 751 | 4.92 / 88.20 | 5 | 137 |
Average= | 4.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.76 | 27 | 14.50 | 497 | 195 | 0.19 / 78.30 | 5 | 74 |
2 | 7 | 2008.68 | 40 | 12.90 | 3047 | 1572 | 1.77 / 79.87 | 74 | 88 |
3 | 13 | 1911.24 | 20 | 13.20 | 2947 | 778 | 2.54 / 80.65 | 5 | 96 |
4 | 13 | 1488.64 | 20 | 13.52 | 2417 | 654 | 3.20 / 81.30 | 5 | 110 |
5 | 13 | 952.96 | 20 | 13.83 | 1696 | 469 | 3.67 / 81.77 | 5 | 123 |
6 | 13 | 405.36 | 20 | 14.19 | 942 | 267 | 3.93 / 82.04 | 5 | 128 |
7 | 13 | 17.72 | 20 | 14.50 | 392 | 114 | 4.05 / 82.15 | 5 | 129 |
8 | 13 | 4.92 | 20 | 14.42 | 376 | 108 | 4.16 / 82.26 | 5 | 129 |
9 | 8 | 0.00 | 3 | 14.48 | 372 | 16 | 4.17 / 82.28 | 5 | 134 |
10 | 14 | 0.00 | 197 | 14.14 | 360 | 1003 | 5.18 / 83.28 | 5 | 141 |
Average= | 4.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.40 | 27 | 14.52 | 510 | 200 | 0.20 / 73.12 | 5 | 74 |
2 | 3 | 1036.76 | 1 | 14.40 | 1866 | 27 | 0.23 / 73.14 | 5 | 48 |
3 | 7 | 2003.84 | 41 | 12.92 | 3043 | 1612 | 1.84 / 74.76 | 48 | 87 |
4 | 13 | 1905.88 | 20 | 13.23 | 2943 | 779 | 2.62 / 75.53 | 5 | 95 |
5 | 13 | 1577.92 | 20 | 13.48 | 2520 | 679 | 3.30 / 76.21 | 5 | 107 |
6 | 13 | 936.04 | 20 | 13.84 | 1670 | 462 | 3.76 / 76.68 | 5 | 124 |
7 | 13 | 500.56 | 20 | 14.12 | 1075 | 304 | 4.06 / 76.98 | 5 | 129 |
8 | 13 | 1.68 | 20 | 14.54 | 367 | 107 | 4.17 / 77.09 | 5 | 130 |
9 | 8 | 0.16 | 3 | 14.54 | 369 | 16 | 4.19 / 77.10 | 5 | 137 |
10 | 14 | 0.04 | 197 | 14.17 | 359 | 1002 | 5.19 / 78.10 | 5 | 135 |
Average= | 4.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.36 | 28 | 14.51 | 506 | 206 | 0.21 / 67.99 | 5 | 72 |
2 | 3 | 954.52 | -1 | 14.51 | 506 | 0 | 0.00 / 67.99 | 5 | 72 |
3 | 7 | 2002.84 | 41 | 12.95 | 3029 | 1608 | 1.81 / 69.60 | 72 | 87 |
4 | 13 | 1910.80 | 20 | 13.21 | 2960 | 782 | 2.60 / 70.38 | 5 | 95 |
5 | 13 | 1399.32 | 20 | 13.57 | 2303 | 625 | 3.22 / 71.00 | 5 | 111 |
6 | 13 | 976.20 | 20 | 13.81 | 1740 | 481 | 3.70 / 71.48 | 5 | 124 |
7 | 13 | 444.00 | 20 | 14.16 | 994 | 282 | 3.98 / 71.76 | 5 | 130 |
8 | 13 | 44.84 | 20 | 14.47 | 436 | 126 | 4.11 / 71.89 | 5 | 129 |
9 | 8 | -0.52 | 3 | 14.56 | 373 | 16 | 4.13 / 71.91 | 5 | 129 |
10 | 14 | -0.40 | 197 | 14.17 | 362 | 1011 | 5.14 / 72.92 | 5 | 136 |
Average= | 4.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.56 | 28 | 14.53 | 497 | 202 | 0.20 / 62.87 | 5 | 69 |
2 | 7 | 2004.44 | 40 | 12.97 | 3028 | 1571 | 1.77 / 64.44 | 69 | 86 |
3 | 13 | 1907.76 | 20 | 13.23 | 2942 | 778 | 2.55 / 65.22 | 5 | 95 |
4 | 13 | 1488.20 | 20 | 13.53 | 2397 | 649 | 3.20 / 65.87 | 5 | 108 |
5 | 13 | 953.08 | 20 | 13.83 | 1692 | 468 | 3.67 / 66.34 | 5 | 123 |
6 | 13 | 421.48 | 20 | 14.17 | 970 | 275 | 3.94 / 66.61 | 5 | 130 |
7 | 13 | 42.36 | 20 | 14.46 | 441 | 128 | 4.07 / 66.74 | 5 | 128 |
8 | 8 | -0.12 | 3 | 14.50 | 376 | 16 | 4.09 / 66.75 | 5 | 136 |
9 | 14 | -0.08 | 197 | 14.13 | 369 | 1027 | 5.11 / 67.78 | 5 | 140 |
Average= | 4.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.92 | 28 | 14.54 | 506 | 206 | 0.21 / 57.81 | 5 | 68 |
2 | 7 | 2002.16 | 40 | 12.94 | 3043 | 1575 | 1.78 / 59.38 | 5 | 87 |
3 | 13 | 1903.16 | 20 | 13.22 | 2933 | 775 | 2.56 / 60.16 | 5 | 96 |
4 | 13 | 1484.76 | 20 | 13.52 | 2416 | 653 | 3.21 / 60.81 | 5 | 110 |
5 | 13 | 854.32 | 20 | 13.88 | 1564 | 434 | 3.64 / 61.25 | 5 | 126 |
6 | 13 | 415.08 | 20 | 14.18 | 962 | 273 | 3.92 / 61.52 | 5 | 129 |
7 | 13 | 46.88 | 20 | 14.48 | 438 | 127 | 4.04 / 61.65 | 5 | 129 |
8 | 8 | -0.04 | 11 | 14.56 | 366 | 59 | 4.10 / 61.71 | 5 | 130 |
9 | 14 | -0.04 | 189 | 14.18 | 359 | 962 | 5.06 / 62.67 | 5 | 133 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.88 | 28 | 14.53 | 490 | 199 | 0.20 / 52.81 | 5 | 70 |
2 | 7 | 2006.32 | 40 | 12.95 | 3037 | 1573 | 1.77 / 54.39 | 70 | 86 |
3 | 13 | 1913.08 | 20 | 13.20 | 2961 | 782 | 2.55 / 55.17 | 5 | 95 |
4 | 13 | 1376.80 | 20 | 13.57 | 2270 | 616 | 3.17 / 55.79 | 5 | 112 |
5 | 13 | 969.28 | 20 | 13.81 | 1728 | 477 | 3.65 / 56.26 | 5 | 124 |
6 | 13 | 223.12 | 20 | 14.31 | 694 | 199 | 3.85 / 56.46 | 5 | 127 |
7 | 13 | 22.68 | 20 | 14.50 | 402 | 117 | 3.96 / 56.58 | 5 | 128 |
8 | 8 | 0.04 | 9 | 14.54 | 372 | 49 | 4.01 / 56.63 | 5 | 129 |
9 | 14 | 0.00 | 191 | 14.16 | 361 | 976 | 4.99 / 57.60 | 5 | 133 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.56 | 28 | 14.54 | 497 | 202 | 0.20 / 47.78 | 5 | 63 |
2 | 7 | 2001.48 | 41 | 12.97 | 3029 | 1611 | 1.81 / 49.40 | 63 | 86 |
3 | 13 | 1904.04 | 20 | 13.22 | 2926 | 774 | 2.59 / 50.17 | 5 | 93 |
4 | 13 | 1383.72 | 20 | 13.56 | 2271 | 616 | 3.20 / 50.78 | 5 | 110 |
5 | 13 | 864.96 | 20 | 13.87 | 1574 | 437 | 3.64 / 51.22 | 5 | 126 |
6 | 13 | 335.12 | 20 | 14.24 | 850 | 242 | 3.88 / 51.46 | 5 | 129 |
7 | 13 | 45.20 | 20 | 14.47 | 446 | 129 | 4.01 / 51.59 | 5 | 131 |
8 | 8 | 0.04 | 3 | 14.57 | 374 | 16 | 4.03 / 51.61 | 5 | 134 |
9 | 14 | -0.04 | 197 | 14.15 | 361 | 1006 | 5.03 / 52.61 | 5 | 136 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.36 | 28 | 14.57 | 502 | 205 | 0.20 / 42.65 | 5 | 67 |
2 | 7 | 2006.20 | 40 | 12.97 | 3039 | 1577 | 1.78 / 44.23 | 67 | 86 |
3 | 13 | 1916.24 | 20 | 13.21 | 2943 | 778 | 2.56 / 45.01 | 5 | 95 |
4 | 13 | 1487.72 | 20 | 13.50 | 2413 | 652 | 3.21 / 45.66 | 5 | 109 |
5 | 13 | 848.20 | 20 | 13.87 | 1560 | 433 | 3.64 / 46.09 | 5 | 125 |
6 | 13 | 319.00 | 20 | 14.22 | 822 | 234 | 3.88 / 46.33 | 5 | 127 |
7 | 13 | 21.92 | 20 | 14.48 | 405 | 117 | 3.99 / 46.44 | 5 | 132 |
8 | 13 | 11.28 | 20 | 14.39 | 391 | 113 | 4.11 / 46.56 | 5 | 133 |
9 | 8 | -0.56 | 3 | 14.43 | 377 | 16 | 4.12 / 46.57 | 5 | 140 |
10 | 14 | -0.48 | 197 | 14.09 | 364 | 1010 | 5.13 / 47.58 | 5 | 140 |
Average= | 4.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.72 | 28 | 14.58 | 499 | 204 | 0.20 / 37.63 | 5 | 67 |
2 | 7 | 2003.60 | 40 | 12.98 | 3024 | 1570 | 1.77 / 39.20 | 67 | 87 |
3 | 13 | 1912.72 | 20 | 13.21 | 2947 | 779 | 2.55 / 39.98 | 5 | 95 |
4 | 13 | 1396.00 | 20 | 13.55 | 2282 | 618 | 3.17 / 40.60 | 5 | 110 |
5 | 13 | 862.36 | 20 | 13.86 | 1577 | 437 | 3.61 / 41.03 | 5 | 124 |
6 | 13 | 334.96 | 20 | 14.20 | 849 | 241 | 3.85 / 41.28 | 5 | 128 |
7 | 13 | 49.12 | 20 | 14.45 | 453 | 131 | 3.98 / 41.41 | 5 | 131 |
8 | 8 | 0.00 | 3 | 14.57 | 377 | 16 | 4.00 / 41.42 | 5 | 138 |
9 | 14 | 0.00 | 197 | 14.14 | 368 | 1025 | 5.02 / 42.45 | 5 | 141 |
Average= | 4.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.96 | 28 | 14.58 | 485 | 198 | 0.20 / 32.57 | 5 | 64 |
2 | 7 | 2002.32 | 41 | 12.97 | 3038 | 1616 | 1.81 / 34.18 | 5 | 87 |
3 | 13 | 1906.92 | 20 | 13.20 | 2930 | 774 | 2.59 / 34.96 | 5 | 93 |
4 | 13 | 1383.32 | 20 | 13.55 | 2270 | 615 | 3.20 / 35.57 | 5 | 109 |
5 | 13 | 970.40 | 20 | 13.80 | 1725 | 476 | 3.68 / 36.05 | 5 | 121 |
6 | 13 | 318.64 | 20 | 14.21 | 822 | 234 | 3.91 / 36.28 | 5 | 123 |
7 | 13 | 23.28 | 20 | 14.50 | 408 | 118 | 4.03 / 36.40 | 5 | 130 |
8 | 8 | -0.08 | 3 | 14.55 | 373 | 16 | 4.05 / 36.42 | 5 | 131 |
9 | 14 | -0.12 | 197 | 14.14 | 363 | 1011 | 5.06 / 37.43 | 5 | 137 |
Average= | 4.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.92 | 28 | 14.56 | 502 | 205 | 0.20 / 27.40 | 5 | 66 |
2 | 7 | 2004.32 | 41 | 12.95 | 3039 | 1614 | 1.82 / 29.01 | 66 | 85 |
3 | 13 | 1905.28 | 20 | 13.21 | 2936 | 776 | 2.59 / 29.79 | 5 | 93 |
4 | 13 | 1466.44 | 20 | 13.49 | 2380 | 642 | 3.24 / 30.43 | 5 | 107 |
5 | 13 | 832.88 | 20 | 13.86 | 1549 | 429 | 3.67 / 30.86 | 5 | 123 |
6 | 13 | 406.88 | 20 | 14.16 | 949 | 269 | 3.93 / 31.13 | 5 | 126 |
7 | 13 | 34.52 | 20 | 14.50 | 419 | 122 | 4.06 / 31.25 | 5 | 127 |
8 | 13 | 2.92 | 20 | 14.46 | 375 | 108 | 4.16 / 31.36 | 5 | 133 |
9 | 8 | -0.20 | 6 | 14.49 | 370 | 32 | 4.20 / 31.39 | 5 | 130 |
10 | 14 | -0.24 | 194 | 14.12 | 358 | 981 | 5.18 / 32.37 | 5 | 135 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.88 | 28 | 14.56 | 499 | 203 | 0.20 / 22.35 | 5 | 68 |
2 | 7 | 2006.44 | 40 | 12.94 | 3024 | 1565 | 1.77 / 23.91 | 5 | 83 |
3 | 13 | 1911.80 | 20 | 13.19 | 2928 | 772 | 2.54 / 24.68 | 5 | 91 |
4 | 13 | 1489.20 | 20 | 13.47 | 2405 | 648 | 3.19 / 25.33 | 5 | 104 |
5 | 13 | 1062.76 | 20 | 13.71 | 1851 | 508 | 3.70 / 25.84 | 5 | 117 |
6 | 13 | 280.24 | 20 | 14.23 | 770 | 219 | 3.92 / 26.06 | 5 | 122 |
7 | 13 | 17.88 | 20 | 14.50 | 396 | 115 | 4.03 / 26.17 | 5 | 128 |
8 | 8 | -0.12 | 3 | 14.55 | 369 | 16 | 4.05 / 26.19 | 5 | 135 |
9 | 14 | -0.12 | 197 | 14.13 | 360 | 1002 | 5.05 / 27.19 | 5 | 136 |
Average= | 3.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.44 | 31 | 14.50 | 496 | 223 | 0.22 / 17.31 | 5 | 74 |
2 | 3 | 876.36 | -2 | 14.50 | 496 | 0 | 0.00 / 17.31 | 5 | 74 |
3 | 7 | 2000.96 | 40 | 12.91 | 3041 | 1570 | 1.79 / 18.88 | 74 | 83 |
4 | 13 | 1795.32 | 20 | 13.26 | 2780 | 737 | 2.53 / 19.61 | 5 | 95 |
5 | 13 | 1384.36 | 20 | 13.50 | 2272 | 613 | 3.14 / 20.23 | 5 | 108 |
6 | 13 | 956.76 | 20 | 13.75 | 1702 | 468 | 3.61 / 20.70 | 5 | 120 |
7 | 13 | 516.20 | 20 | 14.04 | 1096 | 308 | 3.92 / 21.00 | 5 | 126 |
8 | 13 | 17.00 | 20 | 14.48 | 397 | 115 | 4.03 / 21.12 | 5 | 130 |
9 | 8 | -0.08 | 3 | 14.53 | 372 | 16 | 4.05 / 21.13 | 5 | 137 |
10 | 14 | -0.12 | 197 | 14.11 | 363 | 1009 | 5.06 / 22.14 | 5 | 137 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.08 | 28 | 14.50 | 519 | 211 | 0.21 / 13.07 | 5 | 74 |
2 | 7 | 1518.52 | 41 | 13.29 | 2423 | 1320 | 1.53 / 14.39 | 5 | 96 |
3 | 13 | 1446.00 | 20 | 13.42 | 2356 | 632 | 2.16 / 15.02 | 5 | 103 |
4 | 13 | 1148.40 | 20 | 13.61 | 1958 | 533 | 2.70 / 15.55 | 5 | 114 |
5 | 13 | 623.28 | 20 | 13.94 | 1251 | 349 | 3.05 / 15.90 | 5 | 122 |
6 | 13 | 93.96 | 20 | 14.40 | 512 | 147 | 3.19 / 16.05 | 5 | 114 |
7 | 8 | -0.04 | 3 | 14.60 | 378 | 17 | 3.21 / 16.06 | 5 | 132 |
8 | 14 | -0.04 | 197 | 14.11 | 367 | 1020 | 4.23 / 17.08 | 5 | 138 |
Average= | 3.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.24 | 28 | 14.48 | 502 | 204 | 0.20 / 8.78 | 5 | 76 |
2 | 7 | 1481.64 | 41 | 13.26 | 2368 | 1287 | 1.49 / 10.07 | 76 | 97 |
3 | 13 | 1406.84 | 20 | 13.40 | 2300 | 616 | 2.11 / 10.69 | 5 | 104 |
4 | 13 | 1114.44 | 20 | 13.59 | 1927 | 524 | 2.63 / 11.21 | 5 | 114 |
5 | 13 | 688.88 | 20 | 13.86 | 1348 | 374 | 3.00 / 11.58 | 5 | 124 |
6 | 13 | 38.08 | 20 | 14.44 | 439 | 127 | 3.13 / 11.71 | 5 | 126 |
7 | 13 | 19.44 | 20 | 14.34 | 408 | 117 | 3.25 / 11.83 | 5 | 128 |
8 | 8 | -0.12 | 3 | 14.48 | 377 | 16 | 3.26 / 11.84 | 5 | 132 |
9 | 14 | -0.08 | 197 | 14.06 | 365 | 1011 | 4.28 / 12.85 | 5 | 140 |
Average= | 3.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.04 | 31 | 14.42 | 496 | 222 | 0.22 / 4.71 | 5 | 78 |
2 | 3 | 901.56 | -2 | 14.42 | 496 | 0 | 0.00 / 4.71 | 5 | 78 |
3 | 7 | 1442.48 | 40 | 13.17 | 2320 | 1222 | 1.44 / 5.93 | 78 | 96 |
4 | 13 | 1379.76 | 20 | 13.34 | 2253 | 601 | 2.04 / 6.54 | 5 | 103 |
5 | 13 | 1182.24 | 20 | 13.50 | 1992 | 538 | 2.58 / 7.07 | 5 | 112 |
6 | 13 | 650.44 | 20 | 13.85 | 1282 | 355 | 2.94 / 7.43 | 5 | 124 |
7 | 13 | 56.08 | 20 | 14.38 | 450 | 129 | 3.07 / 7.56 | 5 | 111 |
8 | 8 | 0.00 | 12 | 14.46 | 373 | 65 | 3.13 / 7.62 | 5 | 129 |
9 | 14 | 0.04 | 188 | 14.04 | 362 | 956 | 4.09 / 8.58 | 5 | 134 |
Average= | 2.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.80 | 31 | 14.47 | 463 | 208 | 0.21 / 2.14 | 5 | 55 |
2 | 3 | 904.92 | -1 | 14.47 | 463 | 0 | 0.00 / 2.14 | 5 | 55 |
3 | 7 | 930.32 | 40 | 13.36 | 1642 | 877 | 1.09 / 3.02 | 55 | 107 |
4 | 13 | 619.96 | 20 | 13.78 | 1231 | 339 | 1.42 / 3.36 | 5 | 120 |
5 | 13 | 41.52 | 20 | 14.33 | 430 | 123 | 1.55 / 3.48 | 5 | 118 |
6 | 8 | 0.04 | 3 | 14.44 | 375 | 16 | 1.56 / 3.50 | 5 | 134 |
7 | 14 | 0.04 | 197 | 14.05 | 358 | 991 | 2.55 / 4.49 | 5 | 130 |
Average= | 2.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.48 | 30 | 14.42 | 463 | 200 | 0.20 / 0.20 | 5 | 50 |
2 | 7 | 116.28 | 40 | 14.26 | 466 | 266 | 0.47 / 0.47 | 50 | 52 |
3 | 13 | 69.40 | 20 | 14.47 | 412 | 119 | 0.59 / 0.59 | 5 | 62 |
4 | 8 | 0.16 | 317 | 14.25 | 299 | 1351 | 1.94 / 1.94 | 5 | 143 |
Average= | 1.94 (KJ/cycle) |