SIO Argo Site:
Pump Diagnostics Page   



Serial= 7416 WMO= 3901813

Return

←PreviousNext→

Cycle 366 GMT 22/ 6/2022 12:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.36 90 10.60 598 570 0.57 / 1994.09 5 8
2 7 1809.60 100 6.82 3128 2133 2.70 / 1996.22 5 5
3 13 1908.44 20 6.68 3263 436 3.14 / 1996.66 5 5
4 13 1974.60 20 6.53 3363 439 3.58 / 1997.10 5 5
5 13 2024.60 20 6.41 3435 440 4.02 / 1997.54 5 5
6 13 2048.80 20 6.31 3457 436 4.46 / 1997.98 5 5
7 13 2017.00 20 6.27 3428 430 4.89 / 1998.41 5 5
8 13 1965.28 20 6.31 3363 424 5.31 / 1998.83 5 5
9 13 1904.92 20 6.48 3261 423 5.73 / 1999.25 5 5
10 13 1835.36 20 6.56 3148 413 6.15 / 1999.67 5 5
11 13 1755.04 20 6.73 3031 408 6.55 / 2000.07 5 6
12 13 1670.52 20 6.83 2927 400 6.95 / 2000.47 5 8
13 13 1576.24 20 6.98 2809 392 7.35 / 2000.87 5 11
14 13 1270.76 20 7.58 2373 360 7.71 / 2001.23 5 26
15 13 874.12 20 8.45 1795 303 8.01 / 2001.53 5 42
16 13 675.40 20 8.86 1515 268 8.28 / 2001.80 5 52
17 13 248.24 20 9.90 878 174 8.45 / 2001.97 5 62
18 8 -0.24 200 10.59 475 1006 9.46 / 2002.98 5 56
Average= 5.53
(KJ/cycle)

Cycle 365 GMT 17/ 6/2022 6:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.68 90 10.63 617 590 0.59 / 1984.78 5 7
2 7 1829.48 100 6.99 3158 2207 2.80 / 1986.99 5 5
3 13 1912.88 20 7.00 3272 458 3.26 / 1987.44 5 5
4 13 1970.64 20 6.78 3354 455 3.71 / 1987.90 5 5
5 13 2011.04 20 6.79 3448 468 4.18 / 1988.37 5 5
6 13 2000.88 20 6.59 3431 452 4.63 / 1988.82 5 5
7 13 1958.08 20 6.71 3355 450 5.08 / 1989.27 5 5
8 13 1896.44 20 6.84 3264 447 5.53 / 1989.72 5 5
9 13 1823.00 20 7.01 3151 442 5.97 / 1990.16 5 6
10 13 1735.68 20 7.06 3034 428 6.40 / 1990.59 5 8
11 13 1638.40 20 7.20 2910 419 6.82 / 1991.01 5 12
12 13 1540.12 20 7.39 2752 407 7.22 / 1991.41 5 17
13 13 1147.72 20 8.13 2196 357 7.58 / 1991.77 5 35
14 13 841.64 20 8.73 1758 307 7.89 / 1992.08 5 47
15 13 434.56 20 9.59 1156 222 8.11 / 1992.30 5 61
16 13 120.48 20 10.33 672 139 8.25 / 1992.44 5 61
17 8 0.00 220 10.67 462 1084 9.33 / 1993.52 5 67
Average= 5.52
(KJ/cycle)

Cycle 364 GMT 12/ 6/2022 1: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.36 90 10.66 613 588 0.59 / 1975.64 5 8
2 7 1807.24 100 7.23 3154 2280 2.87 / 1977.92 5 5
3 13 1897.12 20 7.12 3279 467 3.34 / 1978.38 5 5
4 13 1950.96 20 7.17 3340 479 3.81 / 1978.86 5 5
5 13 1974.04 20 7.00 3373 472 4.29 / 1979.33 5 5
6 13 1935.44 20 7.03 3319 467 4.75 / 1979.80 5 6
7 13 1881.80 20 7.08 3256 461 5.21 / 1980.26 5 7
8 13 1819.80 20 7.20 3171 457 5.67 / 1980.72 5 8
9 13 1744.08 20 7.28 3047 444 6.11 / 1981.16 5 11
10 13 1655.40 20 7.45 2951 440 6.55 / 1981.60 5 14
11 13 1458.64 20 7.71 2654 409 6.96 / 1982.01 5 24
12 13 1063.48 20 8.47 2100 356 7.32 / 1982.37 5 42
13 13 760.32 20 9.03 1650 298 7.62 / 1982.67 5 53
14 13 348.52 20 9.88 1032 204 7.82 / 1982.87 5 64
15 13 69.72 20 10.52 595 125 7.95 / 1982.99 5 60
16 8 -0.24 240 10.70 465 1194 9.14 / 1984.19 5 70
Average= 5.51
(KJ/cycle)

Cycle 363 GMT 6/ 6/2022 19:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.72 89 10.71 605 577 0.58 / 1966.45 5 8
2 7 1812.52 100 7.41 3163 2344 2.92 / 1968.79 5 6
3 13 1902.68 20 7.34 3292 483 3.40 / 1969.28 5 6
4 13 1955.28 20 7.30 3353 490 3.89 / 1969.77 5 6
5 13 1965.88 20 7.28 3364 490 4.38 / 1970.26 5 6
6 13 1916.24 20 7.34 3301 485 4.87 / 1970.74 5 7
7 13 1851.64 20 7.43 3196 475 5.34 / 1971.21 5 8
8 13 1779.64 20 7.52 3103 467 5.81 / 1971.68 5 12
9 13 1694.56 20 7.58 2997 454 6.26 / 1972.14 5 15
10 13 1598.52 20 7.76 2858 444 6.71 / 1972.58 5 20
11 13 1394.80 20 8.10 2560 415 7.12 / 1972.99 5 30
12 13 989.44 20 8.73 1986 347 7.47 / 1973.34 5 45
13 13 574.56 20 9.53 1357 259 7.73 / 1973.60 5 61
14 13 152.52 20 10.37 737 153 7.88 / 1973.75 5 64
15 8 -0.32 260 10.74 464 1296 9.18 / 1975.05 5 64
Average= 5.50
(KJ/cycle)

Cycle 362 GMT 1/ 6/2022 14:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.36 89 10.72 619 591 0.59 / 1957.49 5 8
2 7 1807.24 100 7.57 3146 2382 2.97 / 1959.87 5 7
3 13 1885.52 20 7.59 3231 490 3.46 / 1960.36 5 7
4 13 1922.08 20 7.56 3304 500 3.96 / 1960.86 5 7
5 13 1906.84 20 7.54 3284 495 4.46 / 1961.35 5 8
6 13 1860.40 20 7.62 3204 488 4.95 / 1961.84 5 10
7 13 1798.40 20 7.69 3118 480 5.43 / 1962.32 5 12
8 13 1720.32 20 7.76 3024 469 5.89 / 1962.79 5 15
9 13 1625.60 20 7.91 2899 459 6.35 / 1963.25 5 21
10 13 1224.48 20 8.53 2312 394 6.75 / 1963.64 5 39
11 13 1127.88 20 8.68 2176 378 7.13 / 1964.02 5 43
12 13 603.88 20 9.56 1413 270 7.40 / 1964.29 5 61
13 13 283.12 20 10.18 922 188 7.58 / 1964.48 5 66
14 13 3.44 20 10.76 486 105 7.69 / 1964.58 5 56
15 8 -0.16 260 10.77 460 1288 8.98 / 1965.87 5 57
Average= 5.49
(KJ/cycle)

Cycle 361 GMT 27/ 5/2022 9:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.68 89 10.74 623 596 0.60 / 1948.38 5 8
2 3 1030.76 1 9.21 2002 18 0.61 / 1948.40 5 5
3 7 1810.48 100 7.71 3143 2423 3.04 / 1950.82 5 8
4 13 1890.52 20 7.69 3276 504 3.54 / 1951.32 5 8
5 13 1934.44 20 7.70 3314 510 4.05 / 1951.83 5 8
6 13 1910.84 20 7.71 3306 510 4.56 / 1952.34 5 9
7 13 1856.32 20 7.71 3217 496 5.06 / 1952.84 5 10
8 13 1788.72 20 7.88 3105 489 5.55 / 1953.33 5 15
9 13 1710.28 20 7.91 3012 476 6.02 / 1953.81 5 19
10 13 1620.20 20 8.07 2896 467 6.49 / 1954.27 5 24
11 13 1420.84 20 8.36 2612 437 6.93 / 1954.71 5 33
12 13 990.84 20 9.01 1986 358 7.29 / 1955.07 5 47
13 13 576.88 20 9.71 1362 265 7.55 / 1955.33 5 64
14 13 143.56 20 10.49 710 149 7.70 / 1955.48 5 66
15 13 29.32 20 10.72 531 114 7.81 / 1955.59 5 61
16 8 -0.32 260 10.79 464 1302 9.11 / 1956.90 5 61
Average= 5.48
(KJ/cycle)

Cycle 360 GMT 22/ 5/2022 5: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.32 89 10.78 616 591 0.59 / 1939.40 5 8
2 7 1808.36 100 7.83 3157 2472 3.06 / 1941.88 5 9
3 13 1881.40 20 7.90 3259 515 3.58 / 1942.39 5 9
4 13 1917.28 20 7.80 3300 515 4.09 / 1942.91 5 9
5 13 1885.32 20 7.80 3265 509 4.60 / 1943.41 5 10
6 13 1821.16 20 7.94 3180 505 5.11 / 1943.92 5 14
7 13 1741.48 20 8.07 3066 495 5.60 / 1944.41 5 19
8 13 1658.52 20 8.17 2929 479 6.08 / 1944.89 5 23
9 13 1568.84 20 8.28 2801 464 6.54 / 1945.36 5 27
10 13 1234.40 20 8.79 2308 406 6.95 / 1945.76 5 42
11 13 816.20 20 9.41 1708 321 7.27 / 1946.08 5 58
12 13 278.20 20 10.28 908 187 7.46 / 1946.27 5 69
13 13 38.20 20 10.73 539 116 7.57 / 1946.39 5 61
14 8 -0.20 280 10.81 461 1395 8.97 / 1947.78 5 75
Average= 5.47
(KJ/cycle)

Cycle 359 GMT 17/ 5/2022 0:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.40 88 10.81 609 579 0.58 / 1930.41 5 8
2 7 1829.88 100 7.91 3181 2516 3.10 / 1932.92 5 9
3 13 1908.20 20 7.99 3267 522 3.62 / 1933.45 5 11
4 13 1943.56 20 7.92 3325 527 4.14 / 1933.97 5 10
5 13 1905.84 20 7.99 3278 524 4.67 / 1934.50 5 12
6 13 1840.16 20 8.05 3186 513 5.18 / 1935.01 5 16
7 13 1758.44 20 8.18 3059 500 5.68 / 1935.51 5 21
8 13 1662.48 20 8.30 2940 488 6.17 / 1936.00 5 25
9 13 1473.64 20 8.54 2678 457 6.63 / 1936.45 5 34
10 13 1070.52 20 9.11 2098 382 7.01 / 1936.84 5 48
11 13 739.56 20 9.57 1614 309 7.32 / 1937.15 5 61
12 13 204.28 20 10.45 803 168 7.49 / 1937.31 5 67
13 8 -0.24 300 10.84 461 1499 8.99 / 1938.81 5 80
Average= 5.46
(KJ/cycle)

Cycle 358 GMT 11/ 5/2022 19:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.76 88 10.81 612 582 0.58 / 1921.49 5 8
2 7 1812.68 100 8.07 3147 2540 3.12 / 1924.03 5 11
3 13 1898.00 20 8.12 3261 530 3.65 / 1924.56 5 12
4 13 1929.40 20 8.08 3311 535 4.19 / 1925.10 5 13
5 13 1885.64 20 8.12 3281 533 4.72 / 1925.63 5 15
6 13 1815.40 20 8.24 3158 520 5.24 / 1926.15 5 18
7 13 1724.44 20 8.37 3028 507 5.75 / 1926.66 5 23
8 13 1531.08 20 8.57 2760 473 6.22 / 1927.13 5 32
9 13 1442.24 20 8.72 2636 460 6.68 / 1927.59 5 36
10 13 1015.40 20 9.26 2017 374 7.05 / 1927.96 5 52
11 13 483.08 20 10.05 1214 244 7.30 / 1928.21 5 68
12 13 87.16 20 10.70 614 131 7.43 / 1928.34 5 63
13 8 -0.20 300 10.86 457 1489 8.92 / 1929.83 5 77
Average= 5.45
(KJ/cycle)

Cycle 357 GMT 6/ 5/2022 15: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.64 88 10.84 597 569 0.57 / 1912.54 5 7
2 7 1819.08 100 8.17 3172 2592 3.16 / 1915.13 5 13
3 13 1890.36 20 8.24 3258 537 3.70 / 1915.66 5 13
4 13 1912.28 20 8.16 3332 544 4.24 / 1916.21 5 13
5 13 1866.80 20 8.29 3236 537 4.78 / 1916.75 5 16
6 13 1799.24 20 8.36 3142 525 5.30 / 1917.27 5 20
7 13 1718.00 20 8.45 3024 511 5.81 / 1917.78 5 25
8 13 1623.80 20 8.54 2891 494 6.31 / 1918.28 5 29
9 13 1306.48 20 8.96 2436 437 6.74 / 1918.71 5 41
10 13 887.36 20 9.51 1833 349 7.09 / 1919.06 5 58
11 13 459.64 20 10.13 1183 240 7.33 / 1919.30 5 69
12 13 69.08 20 10.76 588 127 7.46 / 1919.43 5 63
13 8 -0.28 300 10.87 455 1484 8.94 / 1920.91 5 61
Average= 5.44
(KJ/cycle)

Cycle 356 GMT 1/ 5/2022 10:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.32 88 10.85 607 580 0.58 / 1903.53 5 7
2 7 1829.52 100 8.26 3198 2642 3.22 / 1906.17 5 13
3 13 1896.84 20 8.29 3294 546 3.77 / 1906.72 5 14
4 13 1915.24 20 8.35 3310 553 4.32 / 1907.27 5 15
5 13 1866.04 20 8.35 3233 540 4.86 / 1907.81 5 18
6 13 1789.92 20 8.49 3129 531 5.39 / 1908.34 5 22
7 13 1703.24 20 8.59 3004 516 5.91 / 1908.86 5 26
8 13 1609.56 20 8.69 2870 499 6.41 / 1909.36 5 31
9 13 1193.92 20 9.16 2286 419 6.82 / 1909.77 5 46
10 13 870.08 20 9.58 1821 349 7.17 / 1910.12 5 60
11 13 333.44 20 10.35 1003 208 7.38 / 1910.33 5 70
12 13 65.20 20 10.78 587 127 7.51 / 1910.46 5 63
13 13 34.64 20 10.83 533 115 7.62 / 1910.57 5 63
14 8 -0.36 280 10.89 457 1393 9.02 / 1911.97 5 78
Average= 5.43
(KJ/cycle)

Cycle 355 GMT 26/ 4/2022 5:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.92 88 10.88 595 570 0.57 / 1894.64 5 6
2 7 1831.48 100 8.34 3196 2665 3.24 / 1897.30 6 16
3 13 1895.36 20 8.42 3288 554 3.79 / 1897.86 5 15
4 13 1890.92 20 8.42 3281 553 4.34 / 1898.41 5 17
5 13 1836.20 20 8.47 3231 547 4.89 / 1898.96 5 21
6 13 1768.28 20 8.58 3103 532 5.42 / 1899.49 5 25
7 13 1684.40 20 8.64 3009 520 5.94 / 1900.01 5 29
8 13 1386.40 20 9.01 2580 465 6.41 / 1900.47 5 40
9 13 1077.44 20 9.40 2115 398 6.80 / 1900.87 5 51
10 13 757.20 20 9.81 1638 321 7.13 / 1901.19 5 63
11 13 220.24 20 10.55 826 174 7.30 / 1901.37 5 68
12 8 -0.32 320 10.90 454 1584 8.88 / 1902.95 5 84
Average= 5.42
(KJ/cycle)

Cycle 354 GMT 21/ 4/2022 1:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.88 88 10.87 600 574 0.57 / 1885.94 5 7
2 7 1808.84 100 8.45 3153 2664 3.24 / 1888.61 7 17
3 13 1865.24 20 8.56 3211 550 3.79 / 1889.16 5 18
4 13 1851.16 20 8.57 3208 550 4.34 / 1889.71 5 21
5 13 1803.76 20 8.66 3152 546 4.88 / 1890.25 5 22
6 13 1740.04 20 8.70 3047 530 5.41 / 1890.78 5 26
7 13 1650.92 20 8.83 2938 519 5.93 / 1891.30 5 31
8 13 1353.92 20 9.15 2499 457 6.39 / 1891.76 5 42
9 13 944.92 20 9.62 1905 367 6.76 / 1892.13 5 57
10 13 427.20 20 10.28 1138 234 6.99 / 1892.36 5 70
11 13 126.72 20 10.73 675 145 7.14 / 1892.51 5 66
12 8 -0.20 320 10.92 447 1562 8.70 / 1894.07 5 113
Average= 5.41
(KJ/cycle)

Cycle 353 GMT 15/ 4/2022 20:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.40 88 10.89 603 578 0.58 / 1877.04 5 7
2 7 1831.48 100 8.54 3191 2725 3.30 / 1879.76 7 16
3 13 1882.84 20 8.58 3277 562 3.87 / 1880.33 5 19
4 13 1860.68 20 8.63 3249 561 4.43 / 1880.89 5 21
5 13 1804.96 20 8.68 3154 548 4.97 / 1881.43 5 24
6 13 1724.68 20 8.75 3059 535 5.51 / 1881.97 5 28
7 13 1627.92 20 8.94 2897 518 6.03 / 1882.49 5 33
8 13 1424.28 20 9.14 2615 478 6.50 / 1882.96 5 42
9 13 1107.68 20 9.50 2154 409 6.91 / 1883.37 5 53
10 13 560.84 20 10.15 1351 274 7.19 / 1883.65 5 70
11 13 128.40 20 10.73 687 147 7.34 / 1883.80 5 68
12 8 -0.24 320 10.93 450 1574 8.91 / 1885.37 5 89
Average= 5.40
(KJ/cycle)

Cycle 352 GMT 10/ 4/2022 16:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.72 88 10.91 592 568 0.57 / 1868.23 5 6
2 7 1818.04 100 8.60 3173 2729 3.30 / 1870.96 6 18
3 13 1882.04 20 8.67 3264 566 3.86 / 1871.53 5 20
4 13 1860.28 20 8.73 3250 567 4.43 / 1872.09 5 23
5 13 1804.96 20 8.78 3162 555 4.99 / 1872.65 5 25
6 13 1727.84 20 8.93 3051 545 5.53 / 1873.19 5 30
7 13 1633.52 20 8.98 2910 523 6.05 / 1873.72 5 33
8 13 1326.96 20 9.30 2471 460 6.51 / 1874.17 5 46
9 13 901.32 20 9.75 1866 364 6.88 / 1874.54 5 60
10 13 374.84 20 10.42 1062 221 7.10 / 1874.76 5 70
11 13 82.80 20 10.82 607 131 7.23 / 1874.89 5 65
12 8 -0.32 320 10.94 448 1568 8.80 / 1876.46 5 76
Average= 5.39
(KJ/cycle)

Cycle 351 GMT 5/ 4/2022 12: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.40 88 10.91 597 573 0.57 / 1859.43 5 6
2 7 1835.72 101 8.66 3200 2799 3.37 / 1862.23 6 17
3 13 1894.72 20 8.77 3282 576 3.95 / 1862.80 5 20
4 13 1862.80 20 8.81 3226 568 4.52 / 1863.37 5 23
5 13 1793.68 20 8.87 3138 557 5.07 / 1863.93 5 27
6 13 1711.16 20 8.97 3034 544 5.62 / 1864.47 5 32
7 13 1622.32 20 9.04 2905 525 6.14 / 1865.00 5 36
8 13 1221.96 20 9.46 2336 442 6.58 / 1865.44 5 49
9 13 811.32 20 9.93 1724 342 6.93 / 1865.78 5 64
10 13 287.08 20 10.56 921 195 7.12 / 1865.98 5 70
11 13 44.96 20 10.89 550 120 7.24 / 1866.10 5 62
12 8 -0.28 319 10.95 448 1565 8.81 / 1867.66 5 100
Average= 5.38
(KJ/cycle)

Cycle 350 GMT 31/ 3/2022 7:35: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.52 88 10.94 581 559 0.56 / 1850.68 5 6
2 7 1823.84 100 8.72 3191 2783 3.34 / 1853.46 6 20
3 13 1870.72 20 8.86 3254 577 3.92 / 1854.04 5 21
4 13 1839.92 20 8.87 3226 572 4.49 / 1854.61 5 25
5 13 1777.64 20 8.96 3123 560 5.05 / 1855.17 5 28
6 13 1697.56 20 9.03 3012 544 5.59 / 1855.71 5 33
7 13 1607.96 20 9.13 2888 527 6.12 / 1856.24 5 36
8 13 1187.40 20 9.54 2272 433 6.56 / 1856.67 5 51
9 13 764.28 20 10.00 1652 330 6.89 / 1857.01 5 66
10 13 238.84 20 10.63 853 181 7.07 / 1857.19 5 71
11 13 34.68 20 10.92 531 116 7.18 / 1857.30 5 64
12 8 -0.32 315 10.96 450 1554 8.74 / 1858.86 5 138
Average= 5.37
(KJ/cycle)

Cycle 349 GMT 26/ 3/2022 3:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.36 87 10.92 600 570 0.57 / 1841.96 5 6
2 7 1806.76 100 8.79 3158 2776 3.35 / 1844.74 5 21
3 13 1856.80 20 8.92 3234 577 3.92 / 1845.32 5 23
4 13 1817.16 20 8.95 3178 569 4.49 / 1845.88 5 26
5 13 1750.60 20 9.04 3084 558 5.05 / 1846.44 5 30
6 13 1676.16 20 9.09 2990 544 5.59 / 1846.99 5 34
7 13 1583.44 20 9.17 2872 527 6.12 / 1847.51 5 38
8 13 1152.80 20 9.61 2231 429 6.55 / 1847.94 5 52
9 13 736.48 20 10.05 1613 324 6.87 / 1848.27 5 66
10 13 200.60 20 10.69 800 171 7.04 / 1848.44 5 70
11 13 22.68 20 10.94 512 112 7.16 / 1848.55 5 62
12 8 -0.32 320 10.96 448 1571 8.73 / 1850.12 5 127
Average= 5.36
(KJ/cycle)

Cycle 348 GMT 20/ 3/2022 23: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.72 87 10.94 586 558 0.56 / 1833.23 5 6
2 7 1814.56 100 8.84 3175 2807 3.36 / 1836.04 6 21
3 13 1881.12 20 8.95 3252 582 3.95 / 1836.62 5 22
4 13 1849.68 20 9.00 3196 575 4.52 / 1837.19 5 26
5 13 1773.16 20 9.07 3114 565 5.09 / 1837.76 5 30
6 13 1585.76 20 9.24 2846 526 5.61 / 1838.28 5 37
7 13 1498.52 20 9.33 2716 507 6.12 / 1838.79 5 41
8 13 1077.88 20 9.73 2116 412 6.53 / 1839.20 5 55
9 13 753.16 20 10.08 1628 328 6.86 / 1839.53 5 66
10 13 205.48 20 10.70 805 172 7.03 / 1839.70 5 69
11 13 9.36 20 10.96 492 108 7.14 / 1839.81 5 62
12 8 -0.24 320 10.96 451 1582 8.72 / 1841.39 5 99
Average= 5.35
(KJ/cycle)

Cycle 347 GMT 15/ 3/2022 18:50: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.08 87 10.91 604 573 0.57 / 1824.53 5 6
2 7 1811.08 100 8.86 3161 2801 3.37 / 1827.34 6 21
3 13 1868.36 20 9.00 3223 580 3.95 / 1827.92 5 24
4 13 1832.36 20 9.05 3180 576 4.53 / 1828.49 5 27
5 13 1762.56 20 9.08 3096 562 5.09 / 1829.05 5 30
6 13 1674.56 20 9.19 2964 545 5.64 / 1829.60 5 35
7 13 1380.48 20 9.45 2550 482 6.12 / 1830.08 5 45
8 13 1284.56 20 9.53 2416 460 6.58 / 1830.54 5 49
9 13 653.12 20 10.18 1483 302 6.88 / 1830.84 5 68
10 13 233.96 20 10.67 847 181 7.06 / 1831.02 5 70
11 8 -0.28 332 10.96 453 1648 8.71 / 1832.67 5 131
Average= 5.34
(KJ/cycle)

Cycle 346 GMT 10/ 3/2022 14:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.76 87 10.94 581 553 0.55 / 1815.79 5 6
2 7 1810.32 100 8.86 3161 2801 3.35 / 1818.59 5 21
3 13 1867.68 20 8.96 3220 577 3.93 / 1819.17 5 23
4 13 1836.56 20 9.01 3199 576 4.51 / 1819.75 5 26
5 13 1773.12 20 9.10 3106 565 5.07 / 1820.31 5 29
6 13 1691.32 20 9.19 3005 552 5.62 / 1820.86 5 35
7 13 1384.92 20 9.46 2566 485 6.11 / 1821.35 5 46
8 13 982.16 20 9.85 1987 391 6.50 / 1821.74 5 59
9 13 884.84 20 9.94 1841 366 6.87 / 1822.11 5 63
10 13 208.16 20 10.71 807 173 7.04 / 1822.28 5 70
11 13 19.12 20 10.95 501 110 7.15 / 1822.39 5 63
12 8 -0.16 320 10.97 448 1573 8.72 / 1823.96 5 114
Average= 5.33
(KJ/cycle)

Cycle 345 GMT 5/ 3/2022 10:20: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.60 87 10.92 589 560 0.56 / 1807.23 5 6
2 7 1807.32 100 8.86 3162 2802 3.36 / 1810.03 6 20
3 13 1860.52 20 9.00 3213 578 3.94 / 1810.61 5 23
4 13 1827.96 20 9.06 3177 576 4.52 / 1811.18 5 26
5 13 1763.12 20 9.12 3074 561 5.08 / 1811.75 5 30
6 13 1676.96 20 9.16 2977 545 5.62 / 1812.29 5 34
7 13 1385.84 20 9.45 2561 484 6.11 / 1812.77 5 43
8 13 899.68 20 9.94 1853 368 6.47 / 1813.14 5 60
9 13 810.08 20 10.03 1711 343 6.82 / 1813.49 5 64
10 13 151.00 20 10.79 697 150 6.97 / 1813.64 5 67
11 13 16.60 20 10.96 489 107 7.07 / 1813.74 5 62
12 8 -0.40 305 10.96 447 1494 8.57 / 1815.24 5 137
Average= 5.32
(KJ/cycle)

Cycle 344 GMT 28/ 2/2022 6: 5: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.52 87 10.92 581 552 0.55 / 1798.51 5 6
2 3 1024.24 1 10.05 1990 20 0.57 / 1798.53 5 5
3 7 1815.84 100 8.86 3149 2790 3.36 / 1801.32 5 20
4 13 1879.84 20 8.99 3229 581 3.94 / 1801.90 5 23
5 13 1848.52 20 8.96 3203 574 4.52 / 1802.48 5 25
6 13 1783.28 20 9.05 3106 562 5.08 / 1803.04 5 28
7 13 1702.00 20 9.13 2996 547 5.63 / 1803.59 5 31
8 13 1603.36 20 9.25 2860 529 6.15 / 1804.12 5 37
9 13 1174.36 20 9.66 2255 436 6.59 / 1804.55 5 53
10 13 740.24 20 10.12 1587 321 6.91 / 1804.87 5 65
11 13 305.48 20 10.60 938 199 7.11 / 1805.07 5 69
12 13 20.64 20 10.95 497 109 7.22 / 1805.18 5 58
13 13 7.84 20 10.96 475 104 7.32 / 1805.29 5 60
14 8 -0.40 287 10.96 440 1384 8.71 / 1806.67 5 132
Average= 5.31
(KJ/cycle)

Cycle 343 GMT 23/ 2/2022 1:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.76 82 10.98 574 517 0.52 / 1789.87 5 6
2 10 1020.48 3 10.17 2009 61 0.58 / 1789.93 5 21
3 3 1084.04 2 10.08 2078 42 0.62 / 1789.97 5 15
4 7 1808.36 100 8.92 3134 2796 3.42 / 1792.77 15 21
5 13 1860.36 20 9.02 3242 585 4.00 / 1793.35 5 24
6 13 1824.00 20 9.07 3183 577 4.58 / 1793.93 5 27
7 13 1752.44 20 9.10 3069 559 5.14 / 1794.49 5 31
8 13 1654.28 20 9.24 2922 540 5.68 / 1795.03 5 35
9 13 1455.12 20 9.42 2640 497 6.17 / 1795.53 5 42
10 13 1046.76 20 9.79 2063 404 6.58 / 1795.93 5 56
11 13 630.76 20 10.24 1433 293 6.87 / 1796.22 5 67
12 13 296.52 20 10.61 919 195 7.07 / 1796.42 5 69
13 13 5.28 20 10.96 473 104 7.17 / 1796.52 5 60
14 8 -0.28 301 10.96 436 1438 8.61 / 1797.96 5 144
Average= 5.30
(KJ/cycle)

Cycle 342 GMT 17/ 2/2022 21:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.48 75 11.63 580 506 0.51 / 1781.34 5 7
2 10 1008.84 4 11.47 2023 93 0.60 / 1781.43 5 36
3 10 1036.28 3 11.42 2065 71 0.67 / 1781.50 5 28
4 3 1024.80 1 11.24 2063 23 0.69 / 1781.53 5 5
5 7 1807.04 101 8.98 3158 2864 3.56 / 1784.39 5 16
6 13 1854.00 20 8.94 3182 569 4.13 / 1784.96 5 22
7 13 1815.12 20 9.04 3131 566 4.69 / 1785.53 5 26
8 13 1754.68 20 9.08 3054 555 5.25 / 1786.08 5 29
9 13 1673.92 20 9.19 2932 539 5.79 / 1786.62 5 32
10 13 1378.64 20 9.41 2525 475 6.26 / 1787.10 5 45
11 13 969.00 20 9.86 1932 381 6.64 / 1787.48 5 59
12 13 559.80 20 10.31 1326 273 6.92 / 1787.75 5 67
13 13 135.88 20 10.87 668 145 7.06 / 1787.90 5 63
14 13 28.72 20 11.02 498 110 7.17 / 1788.01 5 60
15 8 -0.28 279 11.01 439 1349 8.52 / 1789.35 5 134
Average= 5.29
(KJ/cycle)

Cycle 341 GMT 12/ 2/2022 17:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.12 70 12.60 591 521 0.52 / 1772.77 5 12
2 10 1030.92 4 12.33 2082 103 0.62 / 1772.88 5 46
3 3 1047.12 1 12.06 2078 25 0.65 / 1772.90 5 7
4 7 1807.84 101 8.84 3147 2810 3.46 / 1775.71 7 19
5 13 1860.36 20 9.74 3235 630 4.09 / 1776.34 5 30
6 13 1821.44 20 9.68 3191 618 4.71 / 1776.96 5 33
7 13 1748.40 20 9.77 3082 602 5.31 / 1777.56 5 37
8 13 1655.60 20 9.89 2952 584 5.89 / 1778.14 5 42
9 13 1350.52 20 10.22 2526 516 6.41 / 1778.66 5 53
10 13 829.28 20 10.80 1750 378 6.79 / 1779.04 5 71
11 13 399.28 20 11.36 1096 249 7.04 / 1779.29 5 78
12 13 21.24 20 11.97 505 121 7.16 / 1779.41 5 71
13 8 -0.28 275 11.68 444 1426 8.58 / 1780.84 5 136
Average= 5.28
(KJ/cycle)

Cycle 340 GMT 7/ 2/2022 13:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.16 69 13.20 606 552 0.55 / 1764.33 5 11
2 7 1812.08 100 8.49 3150 2674 3.23 / 1767.01 5 13
3 13 1880.56 20 9.71 3266 634 3.86 / 1767.64 5 27
4 13 1854.16 20 9.77 3256 636 4.50 / 1768.28 5 31
5 13 1787.12 20 9.92 3136 622 5.12 / 1768.90 5 37
6 13 1691.80 20 10.01 3013 603 5.72 / 1769.50 5 43
7 13 1490.08 20 10.33 2716 561 6.28 / 1770.06 5 51
8 13 970.76 20 11.13 1953 435 6.72 / 1770.50 5 69
9 13 253.00 20 12.25 880 216 6.93 / 1770.71 5 81
10 13 20.88 20 12.67 514 130 7.06 / 1770.84 5 75
11 8 -0.20 254 12.25 453 1410 8.47 / 1772.25 5 129
Average= 5.27
(KJ/cycle)

Cycle 339 GMT 2/ 2/2022 9:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.40 68 13.43 598 546 0.55 / 1755.73 5 14
2 3 1049.76 1 12.21 2091 26 0.57 / 1755.76 5 11
3 7 1812.88 100 8.52 3135 2671 3.24 / 1758.43 11 13
4 13 1884.16 20 9.89 3286 650 3.89 / 1759.08 5 30
5 13 1857.64 20 10.09 3258 657 4.55 / 1759.73 5 35
6 13 1789.40 20 10.26 3142 645 5.19 / 1760.38 5 40
7 13 1693.44 20 10.42 3014 628 5.82 / 1761.01 5 47
8 13 1370.88 20 11.06 2552 565 6.39 / 1761.57 5 62
9 13 933.20 20 11.85 1892 448 6.84 / 1762.02 5 77
10 13 276.56 20 13.22 928 245 7.08 / 1762.27 5 93
11 13 18.68 20 13.76 535 147 7.23 / 1762.41 5 87
12 8 -0.32 231 12.94 457 1366 8.59 / 1763.78 5 129
Average= 5.27
(KJ/cycle)

Cycle 338 GMT 28/ 1/2022 5:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.28 68 13.68 606 564 0.56 / 1747.14 5 18
2 7 1825.24 100 8.46 3166 2678 3.24 / 1749.81 5 14
3 13 1879.00 20 10.13 3278 664 3.91 / 1750.48 5 31
4 13 1844.80 20 10.37 3230 670 4.58 / 1751.15 5 37
5 13 1772.00 20 10.53 3133 660 5.24 / 1751.81 5 43
6 13 1678.16 20 10.69 3015 645 5.88 / 1752.45 5 51
7 13 1474.92 20 11.29 2715 613 6.49 / 1753.07 5 61
8 13 806.84 20 12.75 1710 436 6.93 / 1753.50 5 88
9 13 164.36 20 13.68 759 208 7.14 / 1753.71 5 99
10 8 -0.20 242 13.19 462 1475 8.61 / 1755.18 5 134
Average= 5.26
(KJ/cycle)

Cycle 337 GMT 23/ 1/2022 1:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.00 68 13.82 634 596 0.60 / 1738.51 5 19
2 7 1809.08 100 8.19 3131 2564 3.16 / 1741.08 5 10
3 13 1878.32 20 10.25 3258 668 3.83 / 1741.75 5 32
4 13 1853.32 20 10.58 3240 686 4.51 / 1742.43 5 38
5 13 1788.16 20 10.88 3178 692 5.21 / 1743.12 5 45
6 13 1708.80 20 11.11 3068 682 5.89 / 1743.81 5 52
7 13 1312.52 20 12.34 2474 611 6.50 / 1744.42 5 78
8 13 755.28 20 13.15 1610 423 6.92 / 1744.84 5 91
9 13 215.48 20 13.77 834 230 7.15 / 1745.07 5 94
10 8 -0.24 237 13.46 471 1502 8.65 / 1746.57 5 133
Average= 5.24
(KJ/cycle)

Cycle 336 GMT 17/ 1/2022 21:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.92 68 13.91 631 597 0.60 / 1729.83 5 18
2 7 1811.80 100 8.01 3124 2502 3.10 / 1732.33 18 9
3 13 1889.36 20 10.39 3295 685 3.78 / 1733.02 5 33
4 13 1880.64 20 10.81 3294 712 4.50 / 1733.73 5 40
5 13 1816.92 20 11.24 3218 723 5.22 / 1734.45 5 50
6 13 1730.64 20 11.54 3081 711 5.93 / 1735.16 5 57
7 13 1216.40 20 12.72 2300 585 6.52 / 1735.75 5 81
8 13 688.84 20 13.32 1514 403 6.92 / 1736.15 5 93
9 13 163.68 20 13.88 755 210 7.13 / 1736.36 5 93
10 8 -0.20 242 13.58 474 1558 8.69 / 1737.92 5 131
Average= 5.23
(KJ/cycle)

Cycle 335 GMT 12/ 1/2022 16:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.20 68 13.95 629 597 0.60 / 1721.18 5 22
2 7 1807.40 100 7.97 3114 2482 3.08 / 1723.66 22 9
3 13 1892.84 20 10.55 3303 697 3.78 / 1724.35 5 35
4 13 1887.08 20 11.01 3320 731 4.51 / 1725.09 5 42
5 13 1817.00 20 11.40 3205 731 5.24 / 1725.82 5 51
6 13 1724.56 20 11.69 3072 718 5.96 / 1726.53 5 58
7 13 1314.64 20 12.65 2446 619 6.57 / 1727.15 5 80
8 13 671.76 20 13.40 1491 400 6.97 / 1727.55 5 94
9 13 138.24 20 13.99 725 203 7.18 / 1727.76 5 100
10 8 -0.20 223 13.74 482 1477 8.65 / 1729.23 5 131
Average= 5.22
(KJ/cycle)

Cycle 334 GMT 7/ 1/2022 12:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.28 68 13.99 625 595 0.59 / 1712.57 5 23
2 7 1809.72 100 8.16 3125 2550 3.14 / 1715.12 23 11
3 13 1878.96 20 10.76 3270 704 3.85 / 1715.82 5 39
4 13 1852.12 20 11.30 3255 736 4.58 / 1716.56 5 49
5 13 1779.28 20 11.65 3137 731 5.31 / 1717.29 5 57
6 13 1487.60 20 12.47 2687 670 5.98 / 1717.96 5 72
7 13 1389.16 20 12.64 2513 635 6.62 / 1718.60 5 76
8 13 610.76 20 13.52 1401 379 7.00 / 1718.98 5 97
9 13 75.80 20 14.08 632 178 7.18 / 1719.15 5 97
10 8 -0.24 214 13.82 482 1426 8.60 / 1720.58 5 132
Average= 5.21
(KJ/cycle)

Cycle 333 GMT 2/ 1/2022 8:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.16 68 14.01 623 594 0.59 / 1703.70 5 24
2 7 1810.36 101 8.14 3126 2570 3.16 / 1706.27 24 9
3 13 1881.92 20 10.88 3277 713 3.88 / 1706.98 5 39
4 13 1861.52 20 11.39 3288 749 4.63 / 1707.73 5 47
5 13 1794.88 20 11.70 3176 743 5.37 / 1708.48 5 56
6 13 1708.04 20 12.06 3009 726 6.09 / 1709.20 5 63
7 13 1273.24 20 12.87 2399 618 6.71 / 1709.82 5 83
8 13 695.44 20 13.48 1509 407 7.12 / 1710.23 5 92
9 13 133.04 20 14.01 712 200 7.32 / 1710.43 5 100
10 8 -0.16 233 13.83 481 1550 8.87 / 1711.98 5 130
Average= 5.20
(KJ/cycle)

Cycle 332 GMT 28/12/2021 4:38:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.00 68 14.01 637 607 0.61 / 1694.92 5 24
2 7 1826.72 100 7.97 3149 2510 3.12 / 1697.43 5 9
3 13 1900.08 20 11.01 3338 735 3.85 / 1698.17 5 41
4 13 1894.88 20 11.51 3311 762 4.61 / 1698.93 5 48
5 13 1835.64 20 11.81 3222 761 5.37 / 1699.69 5 55
6 13 1744.48 20 12.13 3077 746 6.12 / 1700.44 5 64
7 13 1206.20 20 12.99 2282 593 6.71 / 1701.03 5 86
8 13 670.00 20 13.49 1475 398 7.11 / 1701.43 5 95
9 13 131.48 20 14.01 718 201 7.31 / 1701.63 5 102
10 8 -0.24 218 13.89 488 1478 8.79 / 1703.11 5 136
Average= 5.19
(KJ/cycle)

Cycle 331 GMT 23/12/2021 0:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.76 68 14.00 633 603 0.60 / 1686.17 5 27
2 7 1806.88 100 7.93 3112 2468 3.07 / 1688.64 5 9
3 13 1883.28 20 11.10 3308 734 3.80 / 1689.37 5 41
4 13 1872.20 20 11.57 3294 762 4.57 / 1690.13 5 50
5 13 1801.80 20 11.94 3182 760 5.33 / 1690.89 5 58
6 13 1703.36 20 12.24 3024 740 6.07 / 1691.64 5 65
7 13 1279.84 20 12.92 2388 617 6.68 / 1692.25 5 85
8 13 633.64 20 13.53 1440 390 7.07 / 1692.64 5 99
9 13 91.72 20 14.06 650 183 7.26 / 1692.82 5 99
10 8 -0.12 219 13.91 490 1493 8.75 / 1694.32 5 144
Average= 5.18
(KJ/cycle)

Cycle 330 GMT 17/12/2021 20:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.80 68 14.02 641 611 0.61 / 1677.55 5 28
2 7 1808.68 100 7.96 3106 2472 3.08 / 1680.03 28 9
3 13 1886.88 20 11.25 3314 746 3.83 / 1680.77 5 43
4 13 1872.92 20 11.67 3297 770 4.60 / 1681.54 5 52
5 13 1799.76 20 12.03 3167 762 5.36 / 1682.30 5 58
6 13 1607.08 20 12.57 2846 715 6.08 / 1683.02 5 70
7 13 1190.24 20 13.03 2240 584 6.66 / 1683.60 5 86
8 13 650.80 20 13.55 1454 394 7.05 / 1684.00 5 96
9 13 45.76 20 14.12 573 162 7.22 / 1684.16 5 97
10 8 -0.16 209 13.96 483 1409 8.62 / 1685.57 5 130
Average= 5.17
(KJ/cycle)

Cycle 329 GMT 12/12/2021 16:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.04 68 14.04 641 612 0.61 / 1668.89 5 29
2 7 1809.64 100 7.92 3112 2465 3.08 / 1671.35 29 9
3 13 1893.28 20 11.31 3291 744 3.82 / 1672.10 5 45
4 13 1888.28 20 11.73 3313 777 4.60 / 1672.87 5 52
5 13 1818.28 20 12.13 3170 769 5.37 / 1673.64 5 60
6 13 1621.24 20 12.55 2889 725 6.09 / 1674.37 5 72
7 13 1106.88 20 13.13 2126 558 6.65 / 1674.92 5 90
8 13 579.64 20 13.61 1351 368 7.02 / 1675.29 5 99
9 13 127.72 20 14.03 702 197 7.22 / 1675.49 5 97
10 8 -0.24 216 13.96 482 1453 8.67 / 1676.94 5 135
Average= 5.16
(KJ/cycle)

Cycle 328 GMT 7/12/2021 12: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.12 68 14.07 627 600 0.60 / 1660.23 5 29
2 7 1807.64 101 7.92 3105 2484 3.08 / 1662.72 29 10
3 13 1884.20 20 11.39 3314 755 3.84 / 1663.47 5 47
4 13 1865.60 20 11.91 3250 774 4.61 / 1664.25 5 54
5 13 1788.76 20 12.28 3082 757 5.37 / 1665.00 5 60
6 13 1598.28 20 12.64 2837 717 6.09 / 1665.72 5 71
7 13 1181.04 20 13.08 2241 586 6.67 / 1666.31 5 87
8 13 552.64 20 13.65 1314 359 7.03 / 1666.66 5 98
9 13 10.44 20 14.17 528 150 7.18 / 1666.81 5 92
10 8 -0.12 216 13.99 483 1460 8.64 / 1668.27 5 131
Average= 5.15
(KJ/cycle)

Cycle 327 GMT 2/12/2021 7:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 68 14.05 645 616 0.62 / 1651.35 5 31
2 7 1832.52 100 7.67 3138 2407 3.02 / 1653.76 31 8
3 13 1907.00 20 11.45 3344 766 3.79 / 1654.52 5 46
4 13 1915.92 20 11.90 3346 796 4.59 / 1655.32 5 52
5 13 1848.60 20 12.13 3245 787 5.37 / 1656.11 5 60
6 13 1756.76 20 12.39 3083 764 6.14 / 1656.87 5 67
7 13 1240.52 20 13.05 2317 605 6.74 / 1657.47 5 87
8 13 720.60 20 13.52 1536 415 7.16 / 1657.89 5 95
9 13 155.92 20 14.02 736 206 7.36 / 1658.10 5 98
10 8 -0.20 228 13.99 482 1537 8.90 / 1659.63 5 134
Average= 5.14
(KJ/cycle)

Cycle 326 GMT 27/11/2021 3:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.00 68 14.05 636 608 0.61 / 1642.58 5 27
2 7 1811.92 100 7.78 3106 2416 3.02 / 1645.00 27 8
3 13 1901.36 20 11.51 3337 768 3.79 / 1645.77 5 46
4 13 1900.08 20 11.96 3292 787 4.58 / 1646.55 5 54
5 13 1830.76 20 12.26 3164 776 5.36 / 1647.33 5 59
6 13 1733.60 20 12.46 3012 751 6.11 / 1648.08 5 66
7 13 1189.00 20 13.11 2246 589 6.70 / 1648.67 5 87
8 13 634.72 20 13.59 1420 386 7.08 / 1649.06 5 95
9 13 102.56 20 14.05 672 189 7.27 / 1649.24 5 100
10 8 -0.16 216 14.00 492 1488 8.76 / 1650.73 5 130
Average= 5.13
(KJ/cycle)

Cycle 325 GMT 21/11/2021 23:26: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.28 68 14.07 631 604 0.60 / 1633.67 5 29
2 7 1809.44 100 7.64 3109 2375 2.98 / 1636.04 29 7
3 13 1898.72 20 11.54 3331 769 3.75 / 1636.81 5 47
4 13 1919.28 20 11.95 3357 802 4.55 / 1637.61 5 51
5 13 1859.88 20 12.23 3235 791 5.34 / 1638.40 5 59
6 13 1765.00 20 12.43 3097 770 6.11 / 1639.17 5 66
7 13 1332.36 20 12.99 2463 640 6.75 / 1639.81 5 82
8 13 882.20 20 13.39 1790 479 7.23 / 1640.29 5 93
9 13 100.80 20 14.04 666 187 7.42 / 1640.48 5 102
10 8 -0.20 218 14.00 490 1495 8.91 / 1641.98 5 140
Average= 5.12
(KJ/cycle)

Cycle 324 GMT 16/11/2021 19:18:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.60 68 14.06 634 606 0.61 / 1625.01 5 29
2 7 1815.12 100 7.63 3125 2384 2.99 / 1627.39 29 8
3 13 1901.28 20 11.67 3333 778 3.77 / 1628.17 5 50
4 13 1911.80 20 12.04 3324 800 4.57 / 1628.97 5 55
5 13 1847.20 20 12.28 3199 786 5.35 / 1629.75 5 61
6 13 1755.88 20 12.50 3069 767 6.12 / 1630.52 5 70
7 13 1219.16 20 13.11 2297 602 6.72 / 1631.12 5 87
8 13 566.04 20 13.65 1333 364 7.09 / 1631.49 5 100
9 13 136.24 20 14.02 715 200 7.29 / 1631.69 5 99
10 8 -0.12 199 14.02 490 1367 8.66 / 1633.06 5 133
11 14 -0.20 1 13.85 488 7 8.66 / 1633.06 7 57
Average= 5.10
(KJ/cycle)

Cycle 323 GMT 11/11/2021 15: 6: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.28 68 14.08 637 610 0.61 / 1616.16 5 26
2 7 1811.36 100 7.69 3104 2387 3.00 / 1618.54 26 8
3 13 1896.76 20 11.73 3321 779 3.78 / 1619.32 5 49
4 13 1897.88 20 12.07 3310 799 4.58 / 1620.12 5 57
5 13 1823.20 20 12.32 3182 784 5.36 / 1620.91 5 62
6 13 1727.68 20 12.53 3027 759 6.12 / 1621.67 5 69
7 13 1190.16 20 13.12 2267 595 6.71 / 1622.26 5 88
8 13 650.16 20 13.59 1454 395 7.11 / 1622.66 5 92
9 13 106.32 20 14.04 676 190 7.30 / 1622.84 5 101
10 8 -0.12 223 14.00 498 1555 8.85 / 1624.40 5 129
Average= 5.09
(KJ/cycle)

Cycle 322 GMT 6/11/2021 11: 2: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.80 68 14.09 635 608 0.61 / 1607.19 5 28
2 7 1831.76 100 7.46 3119 2327 2.94 / 1609.52 28 7
3 13 1908.32 20 11.76 3336 785 3.72 / 1610.30 5 50
4 13 1926.64 20 12.06 3343 806 4.53 / 1611.11 5 54
5 13 1864.68 20 12.31 3220 793 5.32 / 1611.90 5 59
6 13 1776.04 20 12.52 3070 769 6.09 / 1612.67 5 66
7 13 1257.84 20 13.11 2307 605 6.69 / 1613.27 5 87
8 13 819.32 20 13.46 1689 455 7.15 / 1613.73 5 97
9 13 144.40 20 13.99 726 203 7.35 / 1613.93 5 100
10 8 -0.08 235 14.01 491 1617 8.97 / 1615.55 5 136
Average= 5.08
(KJ/cycle)

Cycle 321 GMT 1/11/2021 6:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.72 68 14.04 638 609 0.61 / 1598.44 5 33
2 7 1825.36 100 7.50 3115 2336 2.95 / 1600.78 33 7
3 13 1902.20 20 11.80 3338 788 3.73 / 1601.57 5 52
4 13 1926.68 20 12.10 3330 806 4.54 / 1602.37 5 54
5 13 1869.20 20 12.33 3235 798 5.34 / 1603.17 5 61
6 13 1776.40 20 12.54 3113 781 6.12 / 1603.95 5 67
7 13 1152.48 20 13.18 2193 578 6.70 / 1604.53 5 89
8 13 729.08 20 13.53 1555 421 7.12 / 1604.95 5 97
9 13 91.96 20 14.05 647 182 7.30 / 1605.13 5 98
10 8 -0.20 214 14.05 482 1449 8.75 / 1606.58 5 130
Average= 5.07
(KJ/cycle)

Cycle 320 GMT 27/10/2021 2:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.40 68 14.06 641 613 0.61 / 1589.55 5 31
2 7 1831.20 100 7.40 3114 2304 2.92 / 1591.85 31 7
3 13 1910.56 20 11.81 3355 792 3.71 / 1592.64 5 50
4 13 1934.04 20 12.13 3358 815 4.52 / 1593.46 5 55
5 13 1870.84 20 12.38 3252 805 5.33 / 1594.26 5 61
6 13 1777.44 20 12.58 3097 779 6.11 / 1595.04 5 68
7 13 1457.80 20 12.96 2632 682 6.79 / 1595.72 5 81
8 13 680.76 20 13.55 1495 405 7.20 / 1596.13 5 96
9 13 152.92 20 13.98 742 207 7.40 / 1596.34 5 100
10 8 -0.04 218 14.04 489 1497 8.90 / 1597.83 5 129
Average= 5.06
(KJ/cycle)

Cycle 319 GMT 21/10/2021 22: 2:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.84 67 14.03 645 606 0.61 / 1580.63 5 35
2 7 1819.12 101 7.41 3122 2337 2.94 / 1582.97 5 7
3 13 1922.16 20 11.86 3368 799 3.74 / 1583.77 5 49
4 13 1947.92 20 12.15 3395 825 4.57 / 1584.59 5 54
5 13 1874.80 20 12.41 3238 804 5.37 / 1585.40 5 62
6 13 1776.40 20 12.62 3059 772 6.14 / 1586.17 5 68
7 13 1250.88 20 13.12 2325 610 6.75 / 1586.78 5 88
8 13 721.04 20 13.52 1557 421 7.17 / 1587.20 5 98
9 13 175.60 20 13.98 761 213 7.39 / 1587.41 5 101
10 8 -0.16 223 14.04 486 1522 8.91 / 1588.93 5 131
Average= 5.04
(KJ/cycle)

Cycle 318 GMT 16/10/2021 17:47: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.56 67 14.07 652 615 0.61 / 1571.83 5 32
2 7 1807.76 100 7.49 3070 2299 2.91 / 1574.13 5 8
3 13 1890.28 20 11.93 3320 792 3.71 / 1574.92 5 55
4 13 1916.32 20 12.24 3321 813 4.52 / 1575.73 5 58
5 13 1856.64 20 12.44 3229 803 5.32 / 1576.54 5 64
6 13 1761.24 20 12.62 3064 773 6.10 / 1577.31 5 69
7 13 1452.92 20 12.98 2632 683 6.78 / 1577.99 5 82
8 13 549.80 20 13.66 1308 357 7.14 / 1578.35 5 98
9 13 135.24 20 13.99 712 199 7.34 / 1578.55 5 96
10 8 -0.20 216 14.03 487 1476 8.81 / 1580.03 5 134
Average= 5.03
(KJ/cycle)

Cycle 317 GMT 11/10/2021 13:35:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.12 67 14.05 655 617 0.62 / 1562.81 5 31
2 7 1811.76 100 7.29 3112 2269 2.89 / 1565.08 5 7
3 13 1899.12 20 11.90 3314 789 3.67 / 1565.87 5 51
4 13 1926.00 20 12.20 3364 821 4.49 / 1566.69 5 56
5 13 1861.20 20 12.40 3250 806 5.30 / 1567.49 5 64
6 13 1771.92 20 12.63 3066 774 6.08 / 1568.27 5 69
7 13 1578.48 20 12.87 2817 725 6.80 / 1568.99 5 79
8 13 877.56 20 13.42 1762 473 7.27 / 1569.47 5 97
9 13 195.64 20 13.94 782 218 7.49 / 1569.69 5 102
10 8 -0.20 228 14.05 477 1528 9.02 / 1571.21 5 133
Average= 5.02
(KJ/cycle)

Cycle 316 GMT 6/10/2021 9:30:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.76 66 14.07 643 597 0.60 / 1553.97 5 33
2 3 1046.48 1 11.53 2064 24 0.62 / 1554.00 5 8
3 7 1808.40 100 7.37 3065 2259 2.88 / 1556.25 8 7
4 13 1895.64 20 11.96 3309 792 3.67 / 1557.05 5 52
5 13 1920.44 20 12.27 3316 814 4.49 / 1557.86 5 57
6 13 1861.20 20 12.49 3220 804 5.29 / 1558.66 5 64
7 13 1772.60 20 12.64 3094 782 6.07 / 1559.45 5 68
8 13 1135.24 20 13.21 2166 572 6.64 / 1560.02 5 90
9 13 720.80 20 13.54 1546 419 7.06 / 1560.44 5 97
10 13 167.40 20 13.96 750 209 7.27 / 1560.65 5 96
11 8 -0.20 226 14.03 488 1547 8.82 / 1562.19 5 133
Average= 5.01
(KJ/cycle)

Cycle 315 GMT 1/10/2021 5:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.24 68 14.08 625 598 0.60 / 1545.29 5 32
2 3 967.04 -1 14.08 625 0 0.00 / 1545.29 5 32
3 7 1833.08 100 7.24 3125 2262 2.86 / 1547.55 32 7
4 13 1922.32 20 12.03 3330 801 3.66 / 1548.35 5 53
5 13 1954.28 20 12.30 3376 830 4.49 / 1549.18 5 59
6 13 1889.56 20 12.51 3241 811 5.30 / 1549.99 5 61
7 13 1696.00 20 12.81 2952 756 6.06 / 1550.75 5 73
8 13 1298.40 20 13.12 2392 628 6.69 / 1551.38 5 89
9 13 672.12 20 13.58 1472 400 7.09 / 1551.78 5 98
10 13 132.44 20 13.99 706 198 7.28 / 1551.97 5 98
11 8 0.00 204 14.05 489 1402 8.69 / 1553.37 5 133
Average= 4.99
(KJ/cycle)

Cycle 314 GMT 26/ 9/2021 0:51: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.48 68 14.07 637 609 0.61 / 1536.34 5 32
2 7 1811.36 100 7.28 3091 2250 2.86 / 1538.59 32 7
3 13 1899.28 20 12.00 3336 801 3.66 / 1539.39 5 53
4 13 1930.64 20 12.30 3334 820 4.48 / 1540.21 5 56
5 13 1872.84 20 12.51 3242 811 5.29 / 1541.02 5 63
6 13 1784.76 20 12.64 3128 791 6.08 / 1541.81 5 71
7 13 1275.56 20 13.14 2358 620 6.70 / 1542.43 5 88
8 13 845.64 20 13.45 1720 463 7.16 / 1542.89 5 96
9 13 166.72 20 13.96 745 208 7.37 / 1543.10 5 98
10 8 0.04 231 14.04 490 1589 8.96 / 1544.69 5 129
Average= 4.98
(KJ/cycle)

Cycle 313 GMT 20/ 9/2021 20:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.64 68 14.08 639 612 0.61 / 1527.57 5 27
2 7 1807.60 100 7.29 3083 2248 2.86 / 1529.82 27 7
3 13 1895.16 20 12.07 3292 795 3.65 / 1530.61 5 53
4 13 1922.60 20 12.35 3311 818 4.47 / 1531.43 5 58
5 13 1860.44 20 12.54 3219 807 5.28 / 1532.24 5 63
6 13 1772.52 20 12.71 3071 781 6.06 / 1533.02 5 71
7 13 1071.92 20 13.26 2062 547 6.61 / 1533.56 5 91
8 13 978.36 20 13.35 1909 510 7.12 / 1534.07 5 95
9 13 102.64 20 14.02 654 183 7.30 / 1534.26 5 98
10 8 -0.16 214 14.07 488 1469 8.77 / 1535.73 5 129
Average= 4.97
(KJ/cycle)

Cycle 312 GMT 15/ 9/2021 16: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.68 68 14.07 629 602 0.60 / 1518.56 5 30
2 7 1807.44 100 7.25 3087 2238 2.84 / 1520.80 30 7
3 13 1901.40 20 12.06 3329 803 3.64 / 1521.60 5 53
4 13 1927.04 20 12.35 3331 823 4.47 / 1522.43 5 55
5 13 1859.08 20 12.56 3206 805 5.27 / 1523.23 5 62
6 13 1768.72 20 12.70 3099 787 6.06 / 1524.02 5 69
7 13 1569.04 20 12.96 2778 720 6.78 / 1524.74 5 78
8 13 696.04 20 13.55 1506 408 7.19 / 1525.15 5 95
9 13 143.84 20 13.97 722 202 7.39 / 1525.35 5 94
10 8 -0.04 235 14.05 487 1608 9.00 / 1526.96 5 139
Average= 4.96
(KJ/cycle)

Cycle 311 GMT 10/ 9/2021 11:50: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.92 68 14.07 640 612 0.61 / 1509.73 5 27
2 7 1809.28 100 7.29 3081 2246 2.86 / 1511.98 27 7
3 13 1896.12 20 12.05 3308 797 3.66 / 1512.78 5 53
4 13 1929.40 20 12.35 3336 824 4.48 / 1513.60 5 57
5 13 1871.20 20 12.56 3218 808 5.29 / 1514.41 5 64
6 13 1776.60 20 12.72 3089 786 6.07 / 1515.19 5 70
7 13 1463.72 20 13.01 2638 686 6.76 / 1515.88 5 81
8 13 794.00 20 13.48 1642 443 7.20 / 1516.32 5 93
9 13 144.96 20 13.98 707 198 7.40 / 1516.52 5 99
10 8 -0.08 213 14.09 480 1441 8.84 / 1517.96 5 133
Average= 4.94
(KJ/cycle)

Cycle 310 GMT 5/ 9/2021 7:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.80 68 14.06 634 606 0.61 / 1500.73 5 31
2 7 1807.72 100 7.37 3089 2277 2.88 / 1503.01 31 7
3 13 1899.96 20 12.08 3327 804 3.69 / 1503.81 5 54
4 13 1928.68 20 12.41 3316 823 4.51 / 1504.63 5 55
5 13 1865.04 20 12.59 3204 807 5.32 / 1505.44 5 62
6 13 1773.20 20 12.76 3052 779 6.10 / 1506.22 5 67
7 13 1362.28 20 13.09 2490 652 6.75 / 1506.87 5 84
8 13 915.36 20 13.40 1836 492 7.24 / 1507.36 5 95
9 13 126.84 20 13.98 691 193 7.43 / 1507.56 5 98
10 8 -0.08 228 14.05 488 1563 9.00 / 1509.12 5 130
Average= 4.93
(KJ/cycle)

Cycle 309 GMT 31/ 8/2021 3:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.92 68 14.05 649 620 0.62 / 1491.71 5 26
2 7 1834.72 100 7.37 3117 2297 2.92 / 1494.01 5 7
3 13 1930.40 20 12.13 3349 812 3.73 / 1494.82 5 54
4 13 1967.72 20 12.39 3363 833 4.56 / 1495.66 5 58
5 13 1910.36 20 12.60 3291 829 5.39 / 1496.49 5 62
6 13 1816.36 20 12.74 3111 793 6.19 / 1497.28 5 69
7 13 1394.44 20 13.08 2531 662 6.85 / 1497.94 5 83
8 13 935.04 20 13.40 1857 498 7.34 / 1498.44 5 95
9 13 142.04 20 13.97 714 199 7.54 / 1498.64 5 95
10 8 -0.20 216 14.07 489 1486 9.03 / 1500.12 5 134
Average= 4.92
(KJ/cycle)

Cycle 308 GMT 25/ 8/2021 23: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.76 68 14.04 638 609 0.61 / 1482.84 5 26
2 7 1816.76 100 7.41 3113 2307 2.92 / 1485.15 26 8
3 13 1899.56 20 12.12 3338 809 3.72 / 1485.96 5 54
4 13 1921.24 20 12.43 3324 826 4.55 / 1486.78 5 58
5 13 1857.96 20 12.64 3155 798 5.35 / 1487.58 5 63
6 13 1769.84 20 12.79 3020 773 6.12 / 1488.35 5 69
7 13 1249.60 20 13.17 2314 610 6.73 / 1488.96 5 86
8 13 609.96 20 13.62 1393 379 7.11 / 1489.34 5 96
9 13 175.40 20 13.94 767 214 7.32 / 1489.56 5 96
10 8 -0.04 221 14.05 495 1537 8.86 / 1491.09 5 136
Average= 4.90
(KJ/cycle)

Cycle 307 GMT 20/ 8/2021 18:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.48 68 14.05 630 602 0.60 / 1473.97 5 28
2 7 1823.08 100 7.51 3116 2340 2.94 / 1476.31 28 8
3 13 1920.60 20 12.15 3381 822 3.76 / 1477.13 5 54
4 13 1945.36 20 12.45 3324 828 4.59 / 1477.96 5 58
5 13 1876.08 20 12.62 3181 803 5.39 / 1478.76 5 63
6 13 1676.88 20 12.86 2944 757 6.15 / 1479.52 5 74
7 13 1256.12 20 13.17 2337 616 6.77 / 1480.14 5 87
8 13 612.12 20 13.61 1408 383 7.15 / 1480.52 5 98
9 13 86.80 20 14.01 637 178 7.33 / 1480.70 5 98
10 8 -0.24 226 14.07 483 1536 8.86 / 1482.23 5 135
Average= 4.89
(KJ/cycle)

Cycle 306 GMT 15/ 8/2021 14:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.20 68 14.04 630 601 0.60 / 1465.12 5 27
2 7 1808.16 100 7.63 3101 2366 2.97 / 1467.48 27 10
3 13 1895.28 20 12.20 3305 806 3.77 / 1468.29 5 54
4 13 1911.40 20 12.50 3277 819 4.59 / 1469.11 5 57
5 13 1844.04 20 12.65 3167 801 5.39 / 1469.91 5 63
6 13 1646.44 20 12.89 2887 744 6.14 / 1470.65 5 74
7 13 1226.88 20 13.18 2288 603 6.74 / 1471.26 5 89
8 13 570.08 20 13.64 1345 367 7.11 / 1471.62 5 99
9 13 117.40 20 13.97 681 190 7.30 / 1471.81 5 102
10 8 -0.20 228 14.06 485 1555 8.85 / 1473.37 5 139
Average= 4.88
(KJ/cycle)

Cycle 305 GMT 10/ 8/2021 10:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.72 68 14.05 624 596 0.60 / 1456.34 5 27
2 7 1814.92 100 7.68 3112 2390 2.99 / 1458.73 27 10
3 13 1895.24 20 12.24 3286 804 3.79 / 1459.53 5 54
4 13 1900.64 20 12.48 3266 815 4.61 / 1460.35 5 60
5 13 1828.64 20 12.70 3135 796 5.40 / 1461.14 5 65
6 13 1736.64 20 12.82 2995 768 6.17 / 1461.91 5 69
7 13 1205.84 20 13.20 2246 593 6.76 / 1462.51 5 88
8 13 568.84 20 13.64 1336 364 7.13 / 1462.87 5 99
9 13 124.20 20 13.96 703 196 7.32 / 1463.07 5 103
10 8 -0.12 211 14.07 488 1449 8.77 / 1464.51 5 131
Average= 4.87
(KJ/cycle)

Cycle 304 GMT 5/ 8/2021 6: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.00 68 14.04 622 594 0.59 / 1447.65 5 23
2 7 1811.96 100 7.86 3104 2440 3.03 / 1450.09 23 12
3 13 1901.40 20 12.25 3300 808 3.84 / 1450.90 5 54
4 13 1894.28 20 12.51 3277 820 4.66 / 1451.72 5 60
5 13 1818.92 20 12.72 3100 789 5.45 / 1452.51 5 65
6 13 1621.16 20 12.92 2863 740 6.19 / 1453.25 5 76
7 13 1096.80 20 13.28 2080 552 6.74 / 1453.80 5 89
8 13 454.32 20 13.71 1179 323 7.07 / 1454.12 5 99
9 13 29.08 20 14.06 554 156 7.22 / 1454.28 5 97
10 8 -0.24 211 14.06 493 1463 8.68 / 1455.74 5 133
Average= 4.85
(KJ/cycle)

Cycle 303 GMT 31/ 7/2021 1:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.28 67 14.04 645 607 0.61 / 1438.80 5 23
2 3 1028.64 1 11.35 2045 23 0.63 / 1438.82 5 5
3 7 1809.64 100 7.93 3101 2459 3.09 / 1441.28 5 12
4 13 1888.40 20 12.32 3278 808 3.90 / 1442.09 5 58
5 13 1865.20 20 12.60 3226 813 4.71 / 1442.90 5 61
6 13 1791.72 20 12.75 3101 791 5.50 / 1443.69 5 68
7 13 1697.12 20 12.86 2990 769 6.27 / 1444.46 5 74
8 13 1140.28 20 13.25 2171 575 6.84 / 1445.03 5 90
9 13 485.52 20 13.69 1218 333 7.18 / 1445.37 5 100
10 13 40.76 20 14.06 574 161 7.34 / 1445.53 5 94
11 13 23.44 20 14.11 550 155 7.49 / 1445.68 5 97
12 8 -0.16 194 14.10 487 1332 8.83 / 1447.02 5 139
13 14 -0.12 6 14.13 482 41 8.87 / 1447.06 17 145
Average= 4.84
(KJ/cycle)

Cycle 302 GMT 25/ 7/2021 21:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.76 69 14.05 618 599 0.60 / 1430.05 5 22
2 3 961.04 -1 14.05 618 0 0.00 / 1430.05 5 22
3 7 1830.48 100 7.94 3129 2484 3.08 / 1432.53 22 13
4 13 1902.56 20 12.33 3288 811 3.89 / 1433.34 5 57
5 13 1884.96 20 12.57 3245 816 4.71 / 1434.16 5 62
6 13 1810.80 20 12.72 3114 792 5.50 / 1434.95 5 67
7 13 1615.40 20 12.94 2840 735 6.24 / 1435.69 5 75
8 13 1083.72 20 13.30 2068 550 6.79 / 1436.24 5 90
9 13 439.28 20 13.73 1151 316 7.10 / 1436.55 5 99
10 13 26.92 20 14.06 549 154 7.26 / 1436.71 5 91
11 8 -0.08 212 14.07 497 1482 8.74 / 1438.19 5 139
Average= 4.83
(KJ/cycle)

Cycle 301 GMT 20/ 7/2021 17:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.44 69 14.04 625 605 0.61 / 1421.36 5 24
2 7 1807.08 100 8.09 3107 2514 3.12 / 1423.87 24 13
3 13 1885.32 20 12.36 3277 810 3.93 / 1424.68 5 56
4 13 1871.40 20 12.58 3254 819 4.75 / 1425.50 5 62
5 13 1801.80 20 12.71 3141 798 5.55 / 1426.30 5 68
6 13 1602.64 20 12.93 2819 729 6.28 / 1427.03 5 74
7 13 1054.76 20 13.31 2026 539 6.81 / 1427.57 5 91
8 13 403.84 20 13.75 1098 302 7.12 / 1427.87 5 99
9 13 37.88 20 14.07 560 158 7.27 / 1428.03 5 96
10 8 -0.32 209 14.08 484 1424 8.70 / 1429.45 5 136
Average= 4.81
(KJ/cycle)

Cycle 300 GMT 15/ 7/2021 13:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.52 66 14.01 625 578 0.58 / 1412.49 5 25
2 10 1031.88 3 12.50 2058 77 0.66 / 1412.57 5 41
3 7 1810.12 100 8.28 3106 2572 3.23 / 1415.14 41 16
4 13 1884.52 20 12.41 3260 809 4.04 / 1415.95 5 58
5 13 1847.88 20 12.65 3139 794 4.83 / 1416.74 5 60
6 13 1765.32 20 12.77 3059 781 5.61 / 1417.52 5 68
7 13 1572.52 20 12.94 2783 720 6.33 / 1418.24 5 76
8 13 1126.96 20 13.27 2133 566 6.90 / 1418.81 5 91
9 13 449.48 20 13.71 1154 316 7.21 / 1419.13 5 102
10 13 28.32 20 14.06 549 154 7.37 / 1419.28 5 94
11 8 -0.16 216 14.09 483 1470 8.84 / 1420.75 5 141
Average= 4.80
(KJ/cycle)

Cycle 299 GMT 10/ 7/2021 9:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 68 14.03 625 596 0.60 / 1403.74 5 22
2 3 964.64 -1 14.03 625 0 0.00 / 1403.74 5 22
3 7 1807.12 100 8.24 3094 2549 3.15 / 1406.29 22 16
4 13 1880.64 20 12.45 3215 801 3.95 / 1407.09 5 56
5 13 1854.12 20 12.66 3132 793 4.74 / 1407.89 5 60
6 13 1781.20 20 12.75 3069 783 5.52 / 1408.67 5 69
7 13 1683.20 20 12.87 2914 750 6.27 / 1409.42 5 72
8 13 1135.52 20 13.26 2121 562 6.83 / 1409.98 5 89
9 13 564.00 20 13.63 1313 358 7.19 / 1410.34 5 96
10 13 49.68 20 14.04 573 161 7.35 / 1410.50 5 95
11 8 -0.32 209 14.09 480 1414 8.77 / 1411.91 5 133
Average= 4.79
(KJ/cycle)

Cycle 298 GMT 5/ 7/2021 5:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.96 68 14.02 637 607 0.61 / 1395.18 5 18
2 7 1833.84 100 8.35 3139 2621 3.23 / 1397.80 18 17
3 13 1898.56 20 12.42 3297 819 4.05 / 1398.62 5 60
4 13 1856.20 20 12.62 3185 804 4.85 / 1399.42 5 64
5 13 1771.84 20 12.77 3029 774 5.62 / 1400.20 5 68
6 13 1467.52 20 13.01 2630 684 6.31 / 1400.88 5 81
7 13 834.48 20 13.44 1688 454 6.76 / 1401.34 5 88
8 13 390.20 20 13.75 1071 295 7.06 / 1401.63 5 102
9 8 -0.24 224 14.07 481 1516 8.57 / 1403.15 5 135
Average= 4.77
(KJ/cycle)

Cycle 297 GMT 30/ 6/2021 1:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.08 68 14.03 620 592 0.59 / 1386.61 5 24
2 7 1813.20 100 8.51 3120 2655 3.25 / 1389.27 24 19
3 13 1883.56 20 12.45 3255 810 4.06 / 1390.08 5 57
4 13 1841.40 20 12.64 3169 801 4.86 / 1390.88 5 60
5 13 1754.00 20 12.77 3050 779 5.64 / 1391.66 5 68
6 13 1548.88 20 12.95 2740 710 6.35 / 1392.37 5 79
7 13 800.72 20 13.47 1640 442 6.79 / 1392.81 5 92
8 13 158.56 20 13.94 734 205 6.99 / 1393.01 5 92
9 8 -0.24 230 14.07 482 1560 8.55 / 1394.57 5 133
Average= 4.76
(KJ/cycle)

Cycle 296 GMT 24/ 6/2021 21:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.76 68 14.03 619 591 0.59 / 1378.08 5 24
2 7 1808.76 100 8.61 3112 2679 3.27 / 1380.76 24 19
3 13 1867.36 20 12.47 3247 810 4.08 / 1381.57 5 58
4 13 1816.12 20 12.67 3128 793 4.87 / 1382.36 5 63
5 13 1729.36 20 12.79 2975 761 5.63 / 1383.12 5 68
6 13 1528.68 20 12.94 2724 705 6.34 / 1383.83 5 76
7 13 970.12 20 13.36 1904 509 6.85 / 1384.34 5 93
8 13 206.08 20 13.90 811 225 7.07 / 1384.56 5 91
9 8 -0.32 216 14.07 480 1459 8.53 / 1386.02 5 129
Average= 4.75
(KJ/cycle)

Cycle 295 GMT 19/ 6/2021 18: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.92 68 14.00 617 587 0.59 / 1369.52 5 24
2 7 1815.76 100 8.65 3130 2707 3.29 / 1372.23 24 21
3 13 1897.92 20 12.50 3269 817 4.11 / 1373.05 5 57
4 13 1858.28 20 12.65 3186 806 4.92 / 1373.85 5 63
5 13 1759.52 20 12.76 3024 772 5.69 / 1374.62 5 67
6 13 1542.00 20 12.94 2727 706 6.40 / 1375.33 5 76
7 13 869.64 20 13.43 1725 463 6.86 / 1375.79 5 90
8 13 204.96 20 13.89 807 224 7.08 / 1376.02 5 95
9 8 -0.24 219 14.08 477 1471 8.55 / 1377.49 5 131
Average= 4.73
(KJ/cycle)

Cycle 294 GMT 14/ 6/2021 14: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.44 68 13.99 625 595 0.59 / 1361.16 5 18
2 7 1832.04 100 8.81 3157 2781 3.38 / 1363.94 18 22
3 13 1889.88 20 12.49 3278 819 4.19 / 1364.76 5 59
4 13 1842.24 20 12.62 3187 804 5.00 / 1365.56 5 63
5 13 1752.92 20 12.75 3043 776 5.78 / 1366.34 5 69
6 13 1247.92 20 13.14 2322 610 6.39 / 1366.95 5 86
7 13 627.60 20 13.54 1430 387 6.77 / 1367.33 5 98
8 13 100.60 20 13.98 655 183 6.96 / 1367.52 5 94
9 8 -0.36 211 14.05 478 1417 8.37 / 1368.93 5 130
Average= 4.72
(KJ/cycle)

Cycle 293 GMT 9/ 6/2021 10: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.24 68 13.85 626 590 0.59 / 1352.58 5 21
2 7 1832.32 100 8.93 3158 2820 3.41 / 1355.40 21 24
3 13 1883.72 20 12.38 3278 812 4.22 / 1356.22 5 58
4 13 1831.36 20 12.57 3165 796 5.02 / 1357.01 5 64
5 13 1743.68 20 12.64 3061 774 5.79 / 1357.79 5 68
6 13 1230.72 20 13.09 2291 600 6.39 / 1358.39 5 85
7 13 901.76 20 13.33 1799 480 6.87 / 1358.86 5 90
8 13 125.76 20 13.94 693 193 7.06 / 1359.06 5 100
9 8 -0.16 222 14.02 483 1503 8.57 / 1360.56 5 132
Average= 4.71
(KJ/cycle)

Cycle 292 GMT 4/ 6/2021 6:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.88 68 13.84 631 594 0.59 / 1348.51 5 21
2 7 989.92 100 10.30 1955 2014 2.61 / 1350.52 21 60
3 8 -0.28 222 13.87 478 1472 4.08 / 1351.99 5 140
Average= 4.69
(KJ/cycle)

Cycle 291 GMT 30/ 5/2021 7:11: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.68 68 13.84 629 592 0.59 / 1344.41 5 30
2 7 999.44 100 10.24 1965 2012 2.60 / 1346.42 30 60
3 8 -0.32 225 13.87 478 1492 4.10 / 1347.92 5 129
Average= 4.70
(KJ/cycle)

Cycle 290 GMT 25/ 5/2021 8: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.36 68 13.83 629 592 0.59 / 1340.30 5 19
2 7 1000.52 100 10.23 1974 2019 2.61 / 1342.32 19 56
3 13 30.08 20 13.96 544 152 2.76 / 1342.47 5 97
4 8 -0.16 202 13.87 480 1345 4.11 / 1343.82 5 131
Average= 4.70
(KJ/cycle)

Cycle 289 GMT 20/ 5/2021 8:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.36 68 13.86 622 586 0.59 / 1336.14 5 23
2 7 998.48 100 10.29 1960 2017 2.60 / 1338.16 23 55
3 13 9.36 20 13.98 508 142 2.75 / 1338.30 5 89
4 8 -0.24 212 13.85 481 1412 4.16 / 1339.71 5 131
Average= 4.70
(KJ/cycle)

Cycle 288 GMT 15/ 5/2021 9:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.92 68 13.87 625 589 0.59 / 1332.01 5 23
2 7 998.00 100 10.27 1957 2010 2.60 / 1334.02 23 59
3 8 -0.36 230 13.85 483 1539 4.14 / 1335.55 5 136
Average= 4.70
(KJ/cycle)

Cycle 287 GMT 10/ 5/2021 10:39: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.28 68 13.87 628 592 0.59 / 1328.00 5 22
2 7 984.64 100 10.41 1905 1983 2.58 / 1329.98 22 59
3 8 -0.32 216 13.86 479 1434 4.01 / 1331.42 5 129
Average= 4.70
(KJ/cycle)

Cycle 286 GMT 5/ 5/2021 11:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.96 68 13.88 627 592 0.59 / 1323.96 5 19
2 7 1000.92 100 10.25 1949 1998 2.59 / 1325.96 19 55
3 8 -0.20 216 13.86 483 1446 4.04 / 1327.41 5 129
Average= 4.71
(KJ/cycle)

Cycle 285 GMT 30/ 4/2021 12:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.88 67 14.03 624 587 0.59 / 1319.86 5 17
2 7 1002.40 100 10.24 1950 1997 2.58 / 1321.86 17 60
3 8 -0.36 225 13.88 485 1515 4.10 / 1323.37 5 133
Average= 4.71
(KJ/cycle)

Cycle 284 GMT 25/ 4/2021 12:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.64 68 13.83 625 588 0.59 / 1310.71 5 23
2 7 2018.28 100 8.64 3392 2931 3.52 / 1313.64 23 20
3 13 2056.52 20 12.29 3549 872 4.39 / 1314.51 5 57
4 13 1999.40 20 12.47 3426 854 5.25 / 1315.37 5 60
5 13 1915.32 20 12.61 3285 828 6.07 / 1316.20 5 64
6 13 1501.56 20 12.95 2659 689 6.76 / 1316.89 5 81
7 13 981.08 20 13.29 1922 511 7.27 / 1317.40 5 92
8 13 436.32 20 13.68 1146 314 7.59 / 1317.71 5 102
9 13 39.52 20 14.02 575 161 7.75 / 1317.87 5 101
10 8 -0.28 204 14.03 490 1402 9.15 / 1319.27 5 143
Average= 4.71
(KJ/cycle)

Cycle 283 GMT 20/ 4/2021 8:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 68 13.87 614 579 0.58 / 1306.67 5 22
2 7 975.08 100 10.32 1915 1976 2.56 / 1308.64 22 61
3 13 10.12 20 13.98 510 143 2.70 / 1308.79 5 95
4 8 -0.28 197 13.86 482 1316 4.01 / 1310.10 5 138
5 14 -0.28 3 13.82 482 20 4.03 / 1310.12 9 84
Average= 4.70
(KJ/cycle)

Cycle 282 GMT 15/ 4/2021 9:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.68 68 13.85 614 578 0.58 / 1302.59 5 17
2 7 983.84 100 10.29 1933 1989 2.57 / 1304.58 17 57
3 13 26.36 20 13.95 538 150 2.72 / 1304.73 5 92
4 8 -0.36 207 13.87 475 1364 4.08 / 1306.09 5 140
Average= 4.70
(KJ/cycle)

Cycle 281 GMT 10/ 4/2021 10: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.12 68 13.86 634 598 0.60 / 1298.46 5 17
2 7 992.28 100 10.22 1960 2003 2.60 / 1300.47 17 56
3 13 29.48 20 13.96 539 150 2.75 / 1300.62 5 91
4 8 -0.20 209 13.87 480 1391 4.14 / 1302.01 5 130
Average= 4.70
(KJ/cycle)

Cycle 280 GMT 5/ 4/2021 11: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.16 68 13.85 619 583 0.58 / 1294.37 5 14
2 7 989.36 100 10.26 1947 1998 2.58 / 1296.37 14 57
3 13 26.36 20 13.95 537 150 2.73 / 1296.52 5 95
4 8 -0.36 197 13.88 484 1323 4.05 / 1297.85 5 134
5 14 -0.44 3 13.84 482 20 4.07 / 1297.87 18 76
Average= 4.70
(KJ/cycle)

Cycle 279 GMT 31/ 3/2021 11:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.92 68 13.89 620 586 0.59 / 1290.28 5 12
2 7 981.36 100 10.31 1931 1991 2.58 / 1292.27 12 56
3 13 26.12 20 13.96 535 149 2.73 / 1292.42 5 93
4 8 -0.52 205 13.87 483 1373 4.10 / 1293.79 5 133
Average= 4.70
(KJ/cycle)

Cycle 278 GMT 26/ 3/2021 12:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.04 68 13.92 615 582 0.58 / 1286.14 5 15
2 7 979.56 100 10.38 1929 2002 2.58 / 1288.14 15 62
3 13 10.40 20 13.99 501 140 2.72 / 1288.28 5 95
4 8 -0.44 214 13.88 476 1414 4.14 / 1289.69 5 147
Average= 4.71
(KJ/cycle)

Cycle 277 GMT 21/ 3/2021 13:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.88 68 13.93 615 583 0.58 / 1282.09 5 15
2 7 1006.44 100 10.24 1956 2003 2.59 / 1284.10 5 57
3 8 -0.32 220 13.88 477 1457 4.04 / 1285.55 5 130
Average= 4.71
(KJ/cycle)

Cycle 276 GMT 16/ 3/2021 14:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.40 67 14.07 602 567 0.57 / 1278.06 5 12
2 7 985.72 100 10.31 1923 1983 2.55 / 1280.04 12 57
3 13 22.00 20 13.98 522 146 2.70 / 1280.18 5 93
4 8 -0.60 200 13.92 477 1328 4.02 / 1281.51 5 140
Average= 4.71
(KJ/cycle)

Cycle 275 GMT 11/ 3/2021 15: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.24 68 13.86 620 584 0.58 / 1268.94 5 20
2 7 2007.80 100 8.71 3388 2951 3.54 / 1271.89 20 23
3 13 2063.48 20 12.31 3531 869 4.40 / 1272.76 5 57
4 13 2019.72 20 12.43 3456 859 5.26 / 1273.62 5 60
5 13 1938.80 20 12.58 3293 829 6.09 / 1274.45 5 66
6 13 1427.56 20 12.97 2571 667 6.76 / 1275.11 5 82
7 13 903.08 20 13.34 1800 480 7.24 / 1275.59 5 94
8 13 361.04 20 13.74 1031 283 7.52 / 1275.88 5 102
9 13 15.24 20 14.06 524 147 7.67 / 1276.02 5 99
10 8 -0.44 217 14.03 481 1464 9.13 / 1277.49 5 143
Average= 4.71
(KJ/cycle)

Cycle 274 GMT 6/ 3/2021 10:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.44 68 13.89 615 581 0.58 / 1264.84 5 20
2 7 978.68 100 10.39 1924 1999 2.58 / 1266.84 20 62
3 13 25.52 20 13.96 530 148 2.73 / 1266.99 5 97
4 8 -0.40 206 13.88 477 1364 4.09 / 1268.35 5 136
Average= 4.70
(KJ/cycle)

Cycle 273 GMT 1/ 3/2021 11:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.92 68 13.85 619 583 0.58 / 1260.84 5 18
2 7 982.80 100 10.34 1931 1997 2.58 / 1262.83 18 58
3 8 -0.28 218 13.86 473 1429 4.01 / 1264.26 5 133
Average= 4.70
(KJ/cycle)

Cycle 272 GMT 24/ 2/2021 12:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.76 68 13.86 617 582 0.58 / 1256.78 5 22
2 7 984.00 100 10.34 1938 2004 2.59 / 1258.79 22 61
3 13 8.60 20 13.98 500 140 2.73 / 1258.93 5 92
4 8 -0.28 192 13.88 477 1271 4.00 / 1260.20 5 129
5 14 -0.28 8 13.84 475 53 4.05 / 1260.25 9 128
Average= 4.70
(KJ/cycle)

Cycle 271 GMT 19/ 2/2021 13:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.04 68 13.87 617 582 0.58 / 1252.76 5 21
2 7 991.56 100 10.35 1933 2001 2.58 / 1254.76 21 60
3 8 -0.24 218 13.85 479 1446 4.03 / 1256.20 5 136
Average= 4.70
(KJ/cycle)

Cycle 270 GMT 14/ 2/2021 14: 5: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.32 68 13.90 618 584 0.58 / 1248.70 5 20
2 7 994.60 100 10.34 1934 2000 2.58 / 1250.70 20 58
3 13 12.48 20 13.97 514 144 2.73 / 1250.84 5 96
4 8 -0.28 197 13.87 481 1314 4.04 / 1252.15 5 129
5 14 -0.32 3 13.84 485 20 4.06 / 1252.17 12 78
Average= 4.71
(KJ/cycle)

Cycle 269 GMT 9/ 2/2021 14:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.84 68 13.86 630 594 0.59 / 1244.61 5 22
2 7 993.00 100 10.39 1934 2009 2.60 / 1246.62 22 61
3 8 -0.20 226 13.86 477 1494 4.10 / 1248.11 5 142
Average= 4.71
(KJ/cycle)

Cycle 268 GMT 4/ 2/2021 15:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.20 68 13.85 631 594 0.59 / 1240.60 5 27
2 7 986.80 100 10.40 1891 1967 2.56 / 1242.56 27 60
3 8 -0.24 220 13.88 475 1450 4.01 / 1244.02 5 133
Average= 4.71
(KJ/cycle)

Cycle 267 GMT 30/ 1/2021 16:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.40 67 13.97 637 596 0.60 / 1236.48 5 23
2 7 1018.52 100 10.35 1978 2047 2.64 / 1238.52 5 59
3 8 -0.20 224 13.89 476 1481 4.12 / 1240.00 5 129
Average= 4.71
(KJ/cycle)

Cycle 266 GMT 25/ 1/2021 17:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.60 68 13.85 627 591 0.59 / 1227.46 5 23
2 7 2024.32 100 8.83 3410 3011 3.60 / 1230.47 23 24
3 13 2069.48 20 12.32 3540 872 4.47 / 1231.34 5 58
4 13 2015.76 20 12.44 3449 858 5.33 / 1232.20 5 64
5 13 1930.64 20 12.58 3326 837 6.17 / 1233.04 5 68
6 13 1325.92 20 13.01 2443 636 6.80 / 1233.67 5 87
7 13 900.32 20 13.33 1798 479 7.28 / 1234.15 5 93
8 13 243.52 20 13.82 859 237 7.52 / 1234.39 5 99
9 8 -0.24 223 14.02 477 1491 9.01 / 1235.88 5 136
Average= 4.72
(KJ/cycle)

Cycle 265 GMT 20/ 1/2021 12:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.00 68 13.79 637 597 0.60 / 1223.31 5 29
2 7 1009.24 100 10.40 1943 2021 2.62 / 1225.34 5 56
3 8 -0.16 235 13.87 470 1532 4.15 / 1226.87 5 135
Average= 4.70
(KJ/cycle)

Cycle 264 GMT 15/ 1/2021 13:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.64 68 13.84 610 574 0.57 / 1219.18 5 28
2 7 990.44 100 10.34 1937 2003 2.58 / 1221.18 28 60
3 8 -0.12 237 13.86 468 1537 4.11 / 1222.72 5 130
Average= 4.70
(KJ/cycle)

Cycle 263 GMT 10/ 1/2021 14:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.68 68 13.81 627 589 0.59 / 1215.12 5 31
2 7 1006.08 100 10.37 1918 1989 2.58 / 1217.10 31 58
3 8 -0.04 232 13.86 466 1498 4.08 / 1218.60 5 129
Average= 4.71
(KJ/cycle)

Cycle 262 GMT 5/ 1/2021 15:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.84 68 13.81 623 585 0.59 / 1211.12 5 29
2 7 991.08 100 10.34 1924 1989 2.57 / 1213.11 29 57
3 8 -0.08 216 13.86 474 1419 3.99 / 1214.53 5 140
Average= 4.71
(KJ/cycle)

Cycle 261 GMT 31/12/2020 16: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.20 68 13.81 623 585 0.59 / 1207.02 5 33
2 7 1000.40 100 10.32 1942 2004 2.59 / 1209.02 5 61
3 8 -0.08 233 13.87 467 1509 4.10 / 1210.53 5 145
Average= 4.71
(KJ/cycle)

Cycle 260 GMT 26/12/2020 16:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.48 68 13.85 621 585 0.58 / 1203.04 5 31
2 7 992.80 100 10.37 1930 2001 2.59 / 1205.04 31 61
3 8 -0.16 218 13.88 462 1398 3.98 / 1206.43 5 131
Average= 4.71
(KJ/cycle)

Cycle 259 GMT 21/12/2020 17:47: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.24 68 13.85 625 589 0.59 / 1199.05 5 32
2 7 989.88 100 10.34 1927 1993 2.58 / 1201.04 32 58
3 8 -0.08 218 13.90 464 1406 3.99 / 1202.45 5 132
Average= 4.72
(KJ/cycle)

Cycle 258 GMT 16/12/2020 18:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.36 67 14.01 614 576 0.58 / 1194.97 5 28
2 7 989.04 100 10.37 1921 1992 2.57 / 1196.96 28 60
3 8 -0.12 231 13.90 469 1506 4.07 / 1198.46 5 139
Average= 4.72
(KJ/cycle)

Cycle 257 GMT 11/12/2020 19: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.52 68 13.84 618 582 0.58 / 1185.81 5 31
2 7 2025.64 100 8.87 3387 3004 3.59 / 1188.82 5 21
3 13 2065.36 20 12.30 3535 870 4.46 / 1189.69 5 56
4 13 2005.76 20 12.45 3404 848 5.30 / 1190.53 5 61
5 13 1914.56 20 12.57 3258 819 6.12 / 1191.35 5 66
6 13 1399.64 20 12.97 2541 659 6.78 / 1192.01 5 85
7 13 973.00 20 13.28 1897 504 7.29 / 1192.52 5 96
8 13 421.52 20 13.66 1112 304 7.59 / 1192.82 5 97
9 8 -0.08 236 14.02 474 1568 9.16 / 1194.39 5 134
Average= 4.72
(KJ/cycle)

Cycle 256 GMT 6/12/2020 14:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.88 68 13.83 616 579 0.58 / 1181.83 5 32
2 7 983.12 100 10.34 1933 1999 2.58 / 1183.83 32 64
3 8 -0.12 216 13.88 468 1403 3.98 / 1185.23 5 132
Average= 4.70
(KJ/cycle)

Cycle 255 GMT 1/12/2020 15:38:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.24 68 13.83 627 590 0.59 / 1177.77 5 34
2 7 995.60 100 10.36 1933 2003 2.59 / 1179.77 34 59
3 8 -0.12 228 13.87 468 1480 4.07 / 1181.25 5 134
Average= 4.71
(KJ/cycle)

Cycle 254 GMT 26/11/2020 16:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.32 68 13.82 621 584 0.58 / 1173.68 5 25
2 7 996.64 100 10.34 1954 2020 2.60 / 1175.70 25 59
3 8 -0.12 228 13.87 468 1480 4.08 / 1177.18 5 132
Average= 4.71
(KJ/cycle)

Cycle 253 GMT 21/11/2020 17:18: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.32 68 13.83 615 578 0.58 / 1169.60 5 33
2 7 1010.88 100 10.33 1956 2021 2.60 / 1171.62 5 61
3 8 -0.04 228 13.89 464 1469 4.07 / 1173.09 5 135
Average= 4.71
(KJ/cycle)

Cycle 252 GMT 16/11/2020 18:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.48 68 13.84 621 584 0.58 / 1165.54 5 25
2 7 996.72 100 10.33 1940 2004 2.59 / 1167.55 25 57
3 8 0.04 230 13.88 463 1478 4.07 / 1169.03 5 140
Average= 4.71
(KJ/cycle)

Cycle 251 GMT 11/11/2020 19: 2:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.20 68 13.86 615 580 0.58 / 1161.41 5 28
2 7 1009.96 100 10.33 1967 2032 2.61 / 1163.45 5 60
3 8 -0.04 236 13.89 462 1514 4.13 / 1164.96 5 139
Average= 4.72
(KJ/cycle)

Cycle 250 GMT 6/11/2020 19:52:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.68 68 13.89 609 575 0.58 / 1157.39 5 30
2 7 1005.68 100 10.42 1935 2016 2.59 / 1159.41 30 60
3 8 -0.08 223 13.90 460 1426 4.02 / 1160.83 5 134
Average= 4.72
(KJ/cycle)

Cycle 249 GMT 1/11/2020 20:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.36 67 13.97 620 580 0.58 / 1153.46 5 30
2 7 1009.20 100 10.38 1925 1998 2.58 / 1155.46 5 60
3 8 -0.16 211 13.92 462 1357 3.94 / 1156.82 5 132
Average= 4.72
(KJ/cycle)

Cycle 248 GMT 27/10/2020 21:14: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.68 68 13.81 612 575 0.57 / 1144.41 5 32
2 7 2023.80 100 8.97 3397 3047 3.62 / 1147.46 5 20
3 13 2062.16 20 12.30 3535 870 4.49 / 1148.33 5 56
4 13 2005.32 20 12.47 3405 849 5.34 / 1149.18 5 63
5 13 1914.76 20 12.58 3276 824 6.16 / 1150.00 5 65
6 13 1462.24 20 12.93 2599 672 6.84 / 1150.67 5 82
7 13 1010.56 20 13.26 1941 515 7.35 / 1151.19 5 94
8 13 242.40 20 13.84 844 234 7.59 / 1151.42 5 95
9 8 -0.08 223 14.03 466 1458 9.04 / 1152.88 5 137
Average= 4.72
(KJ/cycle)

Cycle 247 GMT 22/10/2020 17: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.96 68 13.82 621 584 0.58 / 1140.46 5 33
2 7 998.76 100 10.39 1930 2005 2.59 / 1142.47 5 60
3 8 -0.08 216 13.88 457 1370 3.96 / 1143.84 5 135
Average= 4.71
(KJ/cycle)

Cycle 246 GMT 17/10/2020 17:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.20 68 13.84 615 579 0.58 / 1136.44 5 27
2 7 1005.44 100 10.38 1929 2002 2.58 / 1138.44 27 57
3 8 -0.04 223 13.88 464 1436 4.02 / 1139.88 5 135
Average= 4.71
(KJ/cycle)

Cycle 245 GMT 12/10/2020 18:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.40 68 13.83 619 582 0.58 / 1132.41 5 27
2 7 995.92 100 10.37 1914 1985 2.57 / 1134.39 27 57
3 8 -0.16 231 13.89 457 1466 4.03 / 1135.86 5 130
Average= 4.71
(KJ/cycle)

Cycle 244 GMT 7/10/2020 19:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.64 68 13.85 610 574 0.57 / 1128.28 5 30
2 7 1008.64 100 10.35 1958 2027 2.60 / 1130.31 30 60
3 8 0.00 239 13.89 457 1517 4.12 / 1131.83 5 135
Average= 4.72
(KJ/cycle)

Cycle 243 GMT 2/10/2020 20:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.24 68 13.85 617 581 0.58 / 1124.35 5 27
2 7 989.68 100 10.52 1862 1959 2.54 / 1126.31 27 60
3 8 -0.04 219 13.89 460 1399 3.94 / 1127.71 5 131
Average= 4.72
(KJ/cycle)

Cycle 242 GMT 27/ 9/2020 21:14: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.16 68 13.86 619 583 0.58 / 1120.43 5 29
2 7 995.16 100 10.51 1863 1958 2.54 / 1122.39 29 58
3 8 0.00 218 13.90 457 1385 3.93 / 1123.77 5 130
Average= 4.72
(KJ/cycle)

Cycle 241 GMT 22/ 9/2020 22: 7:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.76 68 13.88 604 570 0.57 / 1116.50 5 32
2 7 991.48 100 10.51 1859 1954 2.52 / 1118.45 32 59
3 8 -0.08 220 13.90 456 1394 3.92 / 1119.84 5 132
Average= 4.73
(KJ/cycle)

Cycle 240 GMT 17/ 9/2020 23: 2: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.56 67 13.98 609 570 0.57 / 1112.55 5 31
2 7 986.88 100 10.46 1882 1969 2.54 / 1114.52 31 60
3 8 -0.08 223 13.93 452 1404 3.94 / 1115.93 5 129
Average= 4.73
(KJ/cycle)

Cycle 239 GMT 12/ 9/2020 23:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.04 68 13.82 604 568 0.57 / 1103.59 5 31
2 7 2018.80 100 9.06 3370 3053 3.62 / 1106.64 31 24
3 13 2059.68 20 12.32 3501 863 4.48 / 1107.51 5 58
4 13 1990.48 20 12.49 3371 842 5.33 / 1108.35 5 62
5 13 1803.76 20 12.66 3096 784 6.11 / 1109.13 5 70
6 13 1706.40 20 12.79 2923 748 6.86 / 1109.88 5 74
7 13 822.76 20 13.38 1645 440 7.30 / 1110.32 5 95
8 13 292.96 20 13.79 897 247 7.54 / 1110.57 5 102
9 13 0.80 20 14.15 469 133 7.68 / 1110.70 5 92
10 8 -0.20 197 14.01 458 1264 8.94 / 1111.96 5 132
11 14 -0.20 3 14.01 451 19 8.96 / 1111.98 15 69
Average= 4.73
(KJ/cycle)

Cycle 238 GMT 7/ 9/2020 19: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.92 68 13.87 608 573 0.57 / 1099.71 5 30
2 7 987.24 100 10.50 1868 1961 2.53 / 1101.67 30 59
3 8 0.04 214 13.91 453 1348 3.88 / 1103.02 5 133
Average= 4.71
(KJ/cycle)

Cycle 237 GMT 2/ 9/2020 19:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.32 68 13.88 610 576 0.58 / 1095.75 5 32
2 7 989.56 100 10.45 1914 2000 2.58 / 1097.75 32 59
3 8 -0.04 220 13.89 455 1390 3.97 / 1099.14 5 131
Average= 4.72
(KJ/cycle)

Cycle 236 GMT 28/ 8/2020 20:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.84 68 13.87 605 571 0.57 / 1091.80 5 32
2 7 999.52 100 10.50 1879 1973 2.54 / 1093.77 32 56
3 8 0.00 223 13.90 451 1398 3.94 / 1095.17 5 138
Average= 4.72
(KJ/cycle)

Cycle 235 GMT 23/ 8/2020 21:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.96 68 13.86 621 585 0.59 / 1087.85 5 25
2 7 995.56 100 10.50 1885 1979 2.56 / 1089.83 25 55
3 8 -0.16 222 13.90 454 1401 3.97 / 1091.23 5 133
Average= 4.72
(KJ/cycle)

Cycle 234 GMT 18/ 8/2020 22:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.64 67 13.87 619 575 0.58 / 1083.81 5 30
2 3 1024.40 1 11.90 2042 24 0.60 / 1083.83 5 5
3 7 1029.08 100 10.53 1908 2009 2.61 / 1085.84 5 59
4 8 -0.08 228 13.91 449 1424 4.03 / 1087.27 5 129
Average= 4.73
(KJ/cycle)

Cycle 233 GMT 13/ 8/2020 23:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.04 66 13.86 614 562 0.56 / 1079.76 5 25
2 3 1042.40 1 12.30 2049 25 0.59 / 1079.78 5 6
3 7 1024.56 100 10.55 1897 2001 2.59 / 1081.79 6 56
4 13 11.40 20 14.02 478 134 2.72 / 1081.92 5 96
5 8 -0.04 209 13.91 452 1314 4.04 / 1083.23 5 134
Average= 4.73
(KJ/cycle)

Cycle 232 GMT 9/ 8/2020 0:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.88 68 13.89 595 562 0.56 / 1075.79 5 31
2 3 962.20 -1 13.89 595 0 0.00 / 1075.79 5 31
3 7 1013.00 100 10.61 1871 1985 2.55 / 1077.77 31 58
4 8 -0.20 226 13.91 453 1424 3.97 / 1079.20 5 131
Average= 4.73
(KJ/cycle)

Cycle 231 GMT 4/ 8/2020 0:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.88 67 14.00 603 566 0.57 / 1071.89 5 21
2 7 993.32 100 10.46 1912 2000 2.57 / 1073.89 21 58
3 8 -0.16 216 13.94 445 1340 3.91 / 1075.23 5 130
Average= 4.74
(KJ/cycle)

Cycle 230 GMT 30/ 7/2020 1:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.96 67 13.84 601 557 0.56 / 1062.68 5 31
2 3 1020.24 1 11.72 2030 24 0.58 / 1062.70 5 5
3 7 2027.28 100 9.21 3389 3121 3.70 / 1065.82 5 26
4 13 2044.92 20 12.35 3486 861 4.56 / 1066.68 5 59
5 13 1969.80 20 12.51 3356 840 5.40 / 1067.52 5 62
6 13 1875.48 20 12.62 3196 807 6.21 / 1068.33 5 69
7 13 1672.68 20 12.80 2878 737 6.95 / 1069.07 5 74
8 13 975.40 20 13.26 1880 499 7.45 / 1069.56 5 93
9 13 299.48 20 13.77 908 250 7.70 / 1069.81 5 98
10 13 3.16 20 14.13 472 133 7.83 / 1069.95 5 94
11 8 -0.04 215 14.03 455 1372 9.20 / 1071.32 5 142
Average= 4.74
(KJ/cycle)

Cycle 229 GMT 24/ 7/2020 21:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.00 68 13.85 612 576 0.58 / 1058.73 5 26
2 7 984.48 100 10.56 1854 1958 2.53 / 1060.69 26 57
3 8 0.04 228 13.89 451 1428 3.96 / 1062.12 5 129
Average= 4.72
(KJ/cycle)

Cycle 228 GMT 19/ 7/2020 22:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.04 68 13.87 603 569 0.57 / 1054.70 5 27
2 7 998.72 100 10.45 1933 2020 2.59 / 1056.72 27 61
3 8 -0.12 233 13.89 445 1440 4.03 / 1058.16 5 146
Average= 4.72
(KJ/cycle)

Cycle 227 GMT 14/ 7/2020 23: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.72 68 13.88 622 587 0.59 / 1050.76 5 24
2 7 1001.88 100 10.58 1897 2007 2.59 / 1052.76 24 59
3 8 -0.12 218 13.91 450 1365 3.96 / 1054.13 5 134
Average= 4.73
(KJ/cycle)

Cycle 226 GMT 9/ 7/2020 23:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.24 68 13.86 615 580 0.58 / 1046.77 5 30
2 7 1003.88 100 10.55 1876 1979 2.56 / 1048.75 5 60
3 8 -0.12 226 13.90 453 1423 3.98 / 1050.17 5 142
Average= 4.73
(KJ/cycle)

Cycle 225 GMT 5/ 7/2020 0:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 67 13.91 599 558 0.56 / 1042.71 5 23
2 7 1008.72 100 10.58 1906 2017 2.57 / 1044.73 5 56
3 13 11.48 20 14.00 491 137 2.71 / 1044.87 5 91
4 8 -0.16 207 13.89 459 1320 4.03 / 1046.19 5 134
Average= 4.73
(KJ/cycle)

Cycle 224 GMT 30/ 6/2020 1:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.64 67 13.92 602 561 0.56 / 1038.78 5 29
2 7 1011.00 100 10.58 1897 2007 2.57 / 1040.79 5 59
3 8 -0.16 220 13.92 447 1369 3.94 / 1042.16 5 131
Average= 4.74
(KJ/cycle)

Cycle 223 GMT 25/ 6/2020 2:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.24 67 13.96 590 552 0.55 / 1034.75 5 20
2 7 1010.64 100 10.65 1920 2045 2.60 / 1036.80 5 57
3 8 -0.24 226 13.92 451 1419 4.02 / 1038.22 5 130
Average= 4.74
(KJ/cycle)

Cycle 222 GMT 20/ 6/2020 3:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.24 67 14.02 601 565 0.56 / 1030.75 5 21
2 7 1012.84 100 10.55 1926 2032 2.60 / 1032.78 5 57
3 8 -0.24 228 13.94 447 1421 4.02 / 1034.20 5 132
Average= 4.74
(KJ/cycle)

Cycle 221 GMT 15/ 6/2020 3:56: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.64 67 13.90 606 564 0.56 / 1021.97 5 17
2 7 2009.16 100 9.25 3369 3116 3.68 / 1025.09 17 24
3 13 2035.56 20 12.33 3470 856 4.54 / 1025.94 5 57
4 13 1964.80 20 12.53 3279 822 5.36 / 1026.76 5 61
5 13 1874.32 20 12.62 3189 805 6.16 / 1027.57 5 67
6 13 1448.40 20 12.93 2578 667 6.83 / 1028.24 5 81
7 13 791.28 20 13.41 1579 423 7.25 / 1028.66 5 91
8 13 90.20 20 14.02 599 168 7.42 / 1028.83 5 95
9 8 -0.24 216 14.04 448 1359 8.78 / 1030.19 5 131
Average= 4.75
(KJ/cycle)

Cycle 220 GMT 9/ 6/2020 23:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.52 67 13.91 605 564 0.56 / 1017.97 5 19
2 7 1003.76 100 10.48 1947 2040 2.60 / 1020.01 19 58
3 8 -0.32 220 13.90 457 1398 4.00 / 1021.41 5 129
Average= 4.73
(KJ/cycle)

Cycle 219 GMT 5/ 6/2020 0:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.64 67 13.93 601 561 0.56 / 1013.89 5 21
2 7 1002.20 100 10.59 1885 1996 2.56 / 1015.89 5 55
3 13 32.36 20 13.99 511 143 2.70 / 1016.03 5 94
4 8 -0.32 216 13.91 456 1370 4.07 / 1017.40 5 144
Average= 4.73
(KJ/cycle)

Cycle 218 GMT 31/ 5/2020 1:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.44 67 13.92 597 557 0.56 / 1009.87 5 17
2 7 1008.68 100 10.58 1948 2061 2.62 / 1011.93 17 57
3 8 -0.24 220 13.90 459 1404 4.02 / 1013.33 5 132
Average= 4.74
(KJ/cycle)

Cycle 217 GMT 26/ 5/2020 2:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.24 67 13.92 597 557 0.56 / 1005.85 5 16
2 7 1001.92 100 10.54 1927 2031 2.59 / 1007.88 5 57
3 8 -0.32 226 13.90 456 1432 4.02 / 1009.31 5 145
Average= 4.74
(KJ/cycle)

Cycle 216 GMT 21/ 5/2020 3: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.88 67 13.96 591 553 0.55 / 1001.82 5 16
2 7 1012.52 100 10.60 1902 2016 2.57 / 1003.84 5 60
3 13 33.28 20 14.00 516 144 2.71 / 1003.98 5 93
4 8 -0.40 205 13.91 459 1309 4.02 / 1005.29 5 131
Average= 4.74
(KJ/cycle)

Cycle 215 GMT 16/ 5/2020 3:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.88 67 13.94 598 559 0.56 / 997.90 5 18
2 7 1009.24 100 10.75 1874 2015 2.57 / 999.92 5 55
3 8 -0.28 213 13.92 456 1352 3.93 / 1001.27 5 138
Average= 4.75
(KJ/cycle)

Cycle 214 GMT 11/ 5/2020 4:41: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.92 67 13.98 596 558 0.56 / 993.86 5 16
2 7 1005.44 100 10.73 1888 2026 2.58 / 995.88 16 55
3 8 -0.24 232 13.93 452 1461 4.04 / 997.34 5 135
Average= 4.75
(KJ/cycle)

Cycle 213 GMT 6/ 5/2020 5:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.84 67 14.09 582 549 0.55 / 989.74 5 10
2 7 1014.00 101 10.60 1960 2098 2.65 / 991.84 5 57
3 8 -0.36 228 13.94 459 1459 4.11 / 993.30 5 130
Average= 4.75
(KJ/cycle)

Cycle 212 GMT 1/ 5/2020 6: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.92 67 13.91 598 557 0.56 / 980.76 5 13
2 7 2011.08 100 9.32 3394 3163 3.72 / 983.92 13 25
3 13 2041.72 20 12.29 3464 851 4.57 / 984.77 5 58
4 13 1972.72 20 12.48 3345 835 5.41 / 985.61 5 61
5 13 1874.68 20 12.61 3194 806 6.21 / 986.41 5 66
6 13 1357.52 20 12.96 2458 637 6.85 / 987.05 5 83
7 13 1029.28 20 13.21 1969 520 7.37 / 987.57 5 92
8 13 140.72 20 13.96 675 188 7.56 / 987.76 5 98
9 13 28.80 20 14.12 514 145 7.70 / 987.90 5 93
10 8 -0.32 192 14.04 460 1240 8.94 / 989.14 5 130
11 14 -0.36 8 14.00 450 50 8.99 / 989.19 12 127
Average= 4.76
(KJ/cycle)

Cycle 211 GMT 26/ 4/2020 1:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.72 67 13.94 605 565 0.57 / 976.78 5 11
2 7 985.08 100 10.68 1852 1978 2.54 / 978.76 11 55
3 13 27.56 20 13.98 508 142 2.69 / 978.90 5 92
4 8 -0.44 203 13.89 460 1297 3.98 / 980.20 5 132
Average= 4.74
(KJ/cycle)

Cycle 210 GMT 21/ 4/2020 2:41: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.96 66 13.93 607 558 0.56 / 972.68 5 14
2 3 1045.20 1 12.19 2065 25 0.58 / 972.70 5 6
3 7 1025.28 100 10.61 1938 2056 2.64 / 974.76 6 56
4 13 38.40 20 13.97 531 148 2.79 / 974.91 5 92
5 8 -0.40 206 13.90 457 1309 4.10 / 976.22 5 137
Average= 4.74
(KJ/cycle)

Cycle 209 GMT 16/ 4/2020 3:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.92 68 13.96 582 552 0.55 / 968.67 5 12
2 3 967.92 -1 13.96 582 0 0.00 / 968.67 5 12
3 7 1009.92 100 10.65 1898 2021 2.57 / 970.69 12 55
4 13 13.68 20 14.01 481 135 2.71 / 970.82 5 94
5 8 -0.36 209 13.89 447 1298 4.01 / 972.12 5 130
Average= 4.74
(KJ/cycle)

Cycle 208 GMT 11/ 4/2020 4:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.12 68 13.97 588 559 0.56 / 964.75 5 13
2 7 978.24 100 10.69 1857 1985 2.54 / 966.73 13 57
3 13 23.28 20 14.02 482 135 2.68 / 966.87 5 90
4 8 -0.44 200 13.92 447 1244 3.92 / 968.11 5 136
Average= 4.75
(KJ/cycle)

Cycle 207 GMT 6/ 4/2020 5:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.36 67 13.92 592 552 0.55 / 960.67 5 13
2 7 1018.92 100 10.59 1954 2069 2.62 / 962.74 5 59
3 13 33.04 20 14.02 497 139 2.76 / 962.88 5 95
4 8 -0.36 211 13.92 447 1313 4.07 / 964.19 5 133
Average= 4.75
(KJ/cycle)

Cycle 206 GMT 1/ 4/2020 6: 5: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.92 67 14.00 582 546 0.55 / 956.74 5 16
2 7 1008.48 100 10.74 1840 1976 2.52 / 958.72 5 56
3 13 15.84 20 14.04 470 132 2.65 / 958.85 5 88
4 8 -0.44 203 13.91 448 1265 3.92 / 960.12 5 140
Average= 4.75
(KJ/cycle)

Cycle 205 GMT 27/ 3/2020 6:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.68 67 13.97 589 551 0.55 / 952.75 5 15
2 7 992.12 100 10.82 1861 2014 2.56 / 954.77 15 58
3 13 24.20 20 14.02 501 140 2.71 / 954.91 5 88
4 8 -0.40 204 13.93 454 1290 4.00 / 956.20 5 133
Average= 4.76
(KJ/cycle)

Cycle 204 GMT 22/ 3/2020 7:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.48 67 14.06 584 550 0.55 / 948.77 5 14
2 7 999.48 100 10.79 1887 2036 2.59 / 950.81 14 57
3 8 -0.52 225 13.93 445 1395 3.98 / 952.20 5 138
Average= 4.76
(KJ/cycle)

Cycle 203 GMT 17/ 3/2020 8:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.04 67 13.91 596 555 0.56 / 939.88 5 15
2 7 2009.28 100 9.49 3384 3211 3.77 / 943.09 15 25
3 13 2020.40 20 12.25 3463 848 4.62 / 943.94 5 58
4 13 1952.28 20 12.44 3321 826 5.44 / 944.76 5 62
5 13 1855.96 20 12.56 3151 792 6.23 / 945.55 5 67
6 13 1329.00 20 12.96 2410 625 6.86 / 946.18 5 85
7 13 788.28 20 13.37 1592 426 7.28 / 946.61 5 94
8 13 247.04 20 13.84 826 229 7.51 / 946.83 5 98
9 8 -0.16 220 14.02 450 1388 8.90 / 948.22 5 142
Average= 4.76
(KJ/cycle)

Cycle 202 GMT 12/ 3/2020 3:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.80 67 13.92 601 561 0.56 / 935.95 5 15
2 7 987.24 100 10.70 1900 2033 2.59 / 937.98 15 60
3 8 -0.48 218 13.89 442 1338 3.93 / 939.32 5 134
Average= 4.74
(KJ/cycle)

Cycle 201 GMT 7/ 3/2020 4:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.20 67 13.92 586 547 0.55 / 931.97 5 12
2 7 984.88 100 10.75 1895 2037 2.58 / 934.01 12 61
3 13 5.96 20 14.02 466 131 2.71 / 934.14 5 89
4 8 -0.24 190 13.88 450 1187 3.90 / 935.33 5 130
5 14 -0.28 10 13.83 443 61 3.96 / 935.39 8 127
Average= 4.75
(KJ/cycle)

Cycle 200 GMT 2/ 3/2020 5:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.52 67 13.90 593 552 0.55 / 928.05 5 13
2 7 992.60 100 10.80 1870 2020 2.57 / 930.07 13 57
3 8 -0.24 223 13.88 438 1356 3.93 / 931.43 5 132
Average= 4.75
(KJ/cycle)

Cycle 199 GMT 26/ 2/2020 6:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.08 67 13.91 590 550 0.55 / 924.11 5 17
2 7 985.40 100 10.86 1846 2005 2.55 / 926.12 17 57
3 8 -0.32 225 13.88 442 1380 3.93 / 927.50 5 135
Average= 4.76
(KJ/cycle)

Cycle 198 GMT 21/ 2/2020 7:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.12 67 13.91 588 548 0.55 / 920.20 5 16
2 7 993.84 100 10.84 1846 2001 2.55 / 922.20 16 58
3 8 -0.24 224 13.89 439 1366 3.91 / 923.57 5 133
Average= 4.76
(KJ/cycle)

Cycle 197 GMT 16/ 2/2020 8:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.76 67 13.93 599 559 0.56 / 916.30 5 19
2 7 994.04 100 10.93 1830 2000 2.56 / 918.30 19 61
3 8 -0.32 221 13.89 440 1351 3.91 / 919.65 5 138
Average= 4.77
(KJ/cycle)

Cycle 196 GMT 11/ 2/2020 9:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.04 67 13.93 588 549 0.55 / 912.40 5 15
2 7 999.52 100 10.96 1853 2031 2.58 / 914.43 15 58
3 8 -0.32 213 13.90 441 1306 3.89 / 915.74 5 133
Average= 4.77
(KJ/cycle)

Cycle 195 GMT 6/ 2/2020 10:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.44 67 14.03 591 556 0.56 / 908.43 5 17
2 7 995.08 100 11.07 1858 2057 2.61 / 910.49 17 60
3 13 9.44 20 14.05 461 130 2.74 / 910.62 5 97
4 8 -0.40 197 13.91 444 1217 3.96 / 911.84 5 134
5 14 -0.36 3 13.83 452 19 3.98 / 911.85 16 78
Average= 4.77
(KJ/cycle)

Cycle 194 GMT 1/ 2/2020 10:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.28 67 13.84 604 560 0.56 / 899.56 5 23
2 7 2026.12 101 9.67 3421 3341 3.90 / 902.90 23 27
3 13 2010.44 20 12.22 3428 838 4.74 / 903.74 5 58
4 13 1944.72 20 12.41 3292 817 5.56 / 904.56 5 61
5 13 1854.28 20 12.52 3179 796 6.35 / 905.36 5 66
6 13 1307.32 20 12.96 2360 612 6.96 / 905.97 5 86
7 13 539.64 20 13.55 1241 336 7.30 / 906.30 5 92
8 13 65.20 20 14.05 569 160 7.46 / 906.46 5 99
9 8 -0.16 225 14.00 449 1414 8.87 / 907.88 5 144
Average= 4.78
(KJ/cycle)

Cycle 193 GMT 27/ 1/2020 6:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.52 67 13.84 597 554 0.55 / 895.65 5 24
2 7 971.08 100 10.98 1836 2016 2.57 / 897.66 24 64
3 8 -0.24 218 13.83 445 1342 3.91 / 899.00 5 131
Average= 4.76
(KJ/cycle)

Cycle 192 GMT 22/ 1/2020 7:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.68 67 13.85 594 551 0.55 / 891.76 5 18
2 7 992.08 100 11.05 1827 2019 2.57 / 893.77 18 58
3 8 -0.24 216 13.86 440 1317 3.89 / 895.09 5 130
Average= 4.76
(KJ/cycle)

Cycle 191 GMT 17/ 1/2020 8:20: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.52 67 13.85 592 549 0.55 / 887.72 5 25
2 7 993.48 100 11.03 1838 2027 2.58 / 889.75 25 62
3 8 -0.40 240 13.83 438 1454 4.03 / 891.20 5 136
Average= 4.77
(KJ/cycle)

Cycle 190 GMT 12/ 1/2020 9:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.88 67 13.87 597 555 0.55 / 883.82 5 20
2 7 980.40 100 11.09 1789 1984 2.54 / 885.81 20 60
3 8 -0.28 223 13.83 443 1366 3.91 / 887.17 5 134
Average= 4.77
(KJ/cycle)

Cycle 189 GMT 7/ 1/2020 10:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.96 67 13.86 596 553 0.55 / 879.83 5 18
2 7 988.04 100 11.04 1827 2017 2.57 / 881.84 18 59
3 8 -0.24 235 13.84 438 1425 4.00 / 883.27 5 130
Average= 4.77
(KJ/cycle)

Cycle 188 GMT 2/ 1/2020 11: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.44 67 13.88 593 551 0.55 / 875.95 5 25
2 7 984.40 100 11.12 1795 1996 2.55 / 877.95 25 59
3 8 -0.16 221 13.88 432 1325 3.87 / 879.27 5 136
Average= 4.78
(KJ/cycle)

Cycle 187 GMT 28/12/2019 12: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.32 67 13.87 607 564 0.56 / 871.98 5 19
2 7 998.12 100 11.17 1833 2047 2.61 / 874.03 19 61
3 8 -0.24 223 13.87 444 1373 3.98 / 875.40 5 129
Average= 4.78
(KJ/cycle)

Cycle 186 GMT 23/12/2019 13: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.60 67 13.99 587 550 0.55 / 867.90 5 22
2 7 991.88 100 11.46 1801 2064 2.61 / 869.96 22 63
3 8 -0.24 237 13.86 443 1455 4.07 / 871.42 5 133
Average= 4.79
(KJ/cycle)

Cycle 185 GMT 18/12/2019 13:38:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.96 67 13.82 604 559 0.56 / 859.09 5 22
2 7 2023.64 100 9.84 3401 3347 3.91 / 862.44 5 27
3 13 2001.68 20 12.15 3402 827 4.73 / 863.26 5 56
4 13 1931.76 20 12.36 3271 809 5.54 / 864.07 5 62
5 13 1834.44 20 12.49 3142 785 6.33 / 864.86 5 64
6 13 1393.88 20 12.86 2472 636 6.96 / 865.49 5 79
7 13 611.56 20 13.47 1317 355 7.32 / 865.85 5 91
8 13 91.88 20 14.00 596 167 7.48 / 866.02 5 100
9 8 -0.16 213 13.96 448 1332 8.82 / 867.35 5 129
Average= 4.79
(KJ/cycle)

Cycle 184 GMT 13/12/2019 9:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.52 67 13.79 607 561 0.56 / 855.05 5 23
2 7 1006.16 100 11.17 1862 2080 2.64 / 857.13 23 62
3 8 -0.16 230 13.82 442 1405 4.05 / 858.53 5 135
Average= 4.77
(KJ/cycle)

Cycle 183 GMT 8/12/2019 10:23:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 67 13.81 598 553 0.55 / 851.01 5 25
2 7 1001.80 100 11.20 1856 2079 2.63 / 853.09 25 59
3 8 -0.12 228 13.80 444 1397 4.03 / 854.49 5 139
Average= 4.77
(KJ/cycle)

Cycle 182 GMT 3/12/2019 11:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.36 67 13.81 599 554 0.55 / 846.96 5 22
2 7 999.96 100 11.30 1824 2061 2.62 / 849.03 5 61
3 8 -0.12 232 13.80 447 1431 4.05 / 850.46 5 129
Average= 4.78
(KJ/cycle)

Cycle 181 GMT 28/11/2019 12:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.68 67 13.83 610 565 0.57 / 842.92 5 27
2 7 985.76 100 11.26 1827 2057 2.62 / 844.98 27 64
3 8 -0.12 230 13.80 451 1431 4.05 / 846.41 5 131
Average= 4.78
(KJ/cycle)

Cycle 180 GMT 23/11/2019 13:18:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.00 67 13.82 604 559 0.56 / 838.96 5 28
2 7 1007.60 100 11.33 1839 2084 2.64 / 841.04 5 61
3 8 -0.08 218 13.86 436 1317 3.96 / 842.36 5 132
Average= 4.79
(KJ/cycle)

Cycle 179 GMT 18/11/2019 14:14: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.76 67 13.82 625 579 0.58 / 834.94 5 24
2 7 1008.56 100 11.30 1840 2079 2.66 / 837.02 24 58
3 8 -0.04 225 13.83 443 1379 4.04 / 838.40 5 130
Average= 4.79
(KJ/cycle)

Cycle 178 GMT 13/11/2019 15:10: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.28 67 13.87 605 562 0.56 / 830.86 5 23
2 7 1008.44 100 11.36 1858 2111 2.67 / 832.97 5 60
3 8 -0.28 225 13.85 445 1387 4.06 / 834.36 5 135
Average= 4.80
(KJ/cycle)

Cycle 177 GMT 8/11/2019 16: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.48 67 13.95 602 563 0.56 / 826.78 5 20
2 7 1004.08 100 11.56 1872 2164 2.73 / 828.94 20 62
3 8 -0.24 223 13.87 440 1361 4.09 / 830.30 5 137
Average= 4.80
(KJ/cycle)

Cycle 176 GMT 3/11/2019 16:48:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.68 67 13.81 604 559 0.56 / 817.77 5 24
2 7 2010.20 100 9.96 3411 3397 3.96 / 821.17 24 25
3 13 1985.92 20 12.21 3363 821 4.78 / 821.99 5 55
4 13 1907.36 20 12.41 3220 799 5.58 / 822.79 5 60
5 13 1714.32 20 12.64 2935 742 6.32 / 823.53 5 67
6 13 1306.44 20 12.95 2362 612 6.93 / 824.15 5 82
7 13 646.44 20 13.47 1365 368 7.30 / 824.51 5 92
8 13 305.84 20 13.77 903 249 7.55 / 824.76 5 96
9 8 -0.16 233 13.93 447 1451 9.00 / 826.21 5 133
Average= 4.80
(KJ/cycle)

Cycle 175 GMT 29/10/2019 12:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.56 66 13.84 595 543 0.54 / 813.63 5 24
2 7 1011.40 100 11.40 1861 2122 2.67 / 815.75 5 60
3 8 -0.08 242 13.81 438 1464 4.13 / 817.22 5 134
Average= 4.78
(KJ/cycle)

Cycle 174 GMT 24/10/2019 13:35:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.60 66 13.86 595 544 0.54 / 809.52 5 25
2 7 1016.32 100 11.38 1876 2135 2.68 / 811.65 5 60
3 8 -0.24 233 13.82 445 1433 4.11 / 813.09 5 134
Average= 4.78
(KJ/cycle)

Cycle 173 GMT 19/10/2019 14:29: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.08 68 13.85 601 566 0.57 / 805.40 5 24
2 3 964.12 -1 13.85 601 0 0.00 / 805.40 5 24
3 7 1018.20 100 11.37 1884 2142 2.71 / 807.54 24 60
4 8 -0.04 235 13.87 439 1431 4.14 / 808.97 5 136
Average= 4.79
(KJ/cycle)

Cycle 172 GMT 14/10/2019 15:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.24 69 13.92 595 571 0.57 / 801.39 5 23
2 3 908.56 -1 13.92 595 0 0.00 / 801.39 5 23
3 7 957.76 101 11.64 1791 2106 2.68 / 803.49 23 61
4 8 -0.20 221 13.89 438 1345 4.02 / 804.84 5 137
Average= 4.79
(KJ/cycle)

Cycle 171 GMT 9/10/2019 16:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.32 93 13.80 604 775 0.78 / 795.09 5 31
2 3 57.56 -15 13.80 604 0 0.00 / 795.09 5 31
3 7 1316.16 100 11.81 2399 2833 3.61 / 797.93 31 27
4 13 1256.28 20 13.06 2330 609 4.22 / 798.53 5 45
5 13 1066.20 20 13.23 2026 536 4.75 / 799.07 5 58
6 13 414.48 20 13.70 1066 292 5.05 / 799.36 5 80
7 8 0.00 237 13.98 438 1451 6.50 / 800.81 5 138
Average= 4.80
(KJ/cycle)

Cycle 170 GMT 9/10/2019 3:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.00 67 13.91 552 514 0.51 / 790.08 5 5
2 10 1031.92 8 13.26 1990 211 0.73 / 790.29 5 44
3 10 1099.08 6 13.31 2112 169 0.89 / 790.46 5 48
4 10 1140.12 4 13.33 2165 115 1.01 / 790.58 5 46
5 10 1177.16 3 13.35 2220 89 1.10 / 790.67 5 47
6 3 1172.36 4 12.90 2190 113 1.21 / 790.78 5 61
7 7 1060.08 100 11.34 1933 2192 3.40 / 792.97 61 60
8 8 -0.16 221 13.89 438 1345 4.75 / 794.32 5 133
Average= 4.79
(KJ/cycle)

Cycle 169 GMT 4/10/2019 4:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.76 67 13.86 595 553 0.55 / 785.72 5 24
2 7 991.20 100 11.55 1835 2119 2.67 / 787.84 24 60
3 8 -0.20 291 13.85 429 1729 4.40 / 789.57 5 130
Average= 4.79
(KJ/cycle)

Cycle 168 GMT 29/ 9/2019 5:50: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.68 66 13.97 594 548 0.55 / 781.61 5 23
2 7 1004.76 100 11.82 1876 2217 2.77 / 783.83 5 61
3 8 -0.12 223 13.90 431 1336 4.10 / 785.17 5 131
Average= 4.79
(KJ/cycle)

Cycle 167 GMT 24/ 9/2019 6:30:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.56 67 13.81 598 553 0.55 / 772.87 5 33
2 7 2024.52 100 10.18 3406 3467 4.02 / 776.34 5 27
3 13 1987.48 20 12.21 3361 821 4.84 / 777.16 5 53
4 13 1909.80 20 12.42 3226 801 5.64 / 777.96 5 58
5 13 1813.76 20 12.55 3038 763 6.41 / 778.72 5 62
6 13 1167.36 20 13.06 2132 557 6.96 / 779.28 5 83
7 13 518.00 20 13.58 1207 328 7.29 / 779.61 5 93
8 13 21.48 20 14.15 483 137 7.43 / 779.74 5 87
9 8 0.00 216 13.99 438 1324 8.75 / 781.07 5 140
Average= 4.79
(KJ/cycle)

Cycle 166 GMT 19/ 9/2019 2:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.60 67 13.81 599 554 0.55 / 768.87 5 32
2 7 1002.40 100 11.64 1847 2150 2.70 / 771.02 32 60
3 8 -0.08 216 13.84 435 1300 4.00 / 772.32 5 135
Average= 4.77
(KJ/cycle)

Cycle 165 GMT 14/ 9/2019 3:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.68 67 13.80 608 562 0.56 / 764.84 5 30
2 7 1016.24 100 11.63 1872 2177 2.74 / 767.02 30 59
3 8 -0.20 216 13.85 433 1295 4.03 / 768.31 5 130
Average= 4.77
(KJ/cycle)

Cycle 164 GMT 9/ 9/2019 4:18:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.12 67 13.81 600 555 0.56 / 760.75 5 33
2 7 1002.84 100 11.65 1851 2156 2.71 / 762.91 5 59
3 8 0.08 226 13.83 439 1372 4.08 / 764.28 5 143
Average= 4.78
(KJ/cycle)

Cycle 163 GMT 4/ 9/2019 5:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.88 67 13.82 606 561 0.56 / 756.74 5 28
2 7 995.04 100 11.66 1843 2149 2.71 / 758.89 28 59
3 8 -0.16 216 13.85 436 1304 4.01 / 760.19 5 132
Average= 4.78
(KJ/cycle)

Cycle 162 GMT 30/ 8/2019 6:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.24 67 13.83 601 557 0.56 / 752.67 5 28
2 7 992.40 100 11.66 1841 2147 2.70 / 754.82 28 60
3 8 -0.08 228 13.85 432 1364 4.07 / 756.18 5 131
Average= 4.79
(KJ/cycle)

Cycle 161 GMT 25/ 8/2019 7:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.40 67 13.86 599 556 0.56 / 748.57 5 29
2 7 992.08 100 11.69 1831 2140 2.70 / 750.71 29 60
3 8 -0.12 228 13.84 445 1404 4.10 / 752.11 5 132
Average= 4.79
(KJ/cycle)

Cycle 160 GMT 20/ 8/2019 8:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.48 67 13.83 613 568 0.57 / 744.48 5 29
2 7 980.16 100 11.76 1820 2140 2.71 / 746.62 29 61
3 8 -0.12 228 13.87 441 1395 4.10 / 748.01 5 140
Average= 4.79
(KJ/cycle)

Cycle 159 GMT 15/ 8/2019 9:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.36 66 13.94 604 556 0.56 / 740.29 5 24
2 3 1031.12 1 11.80 2006 24 0.58 / 740.31 5 5
3 7 1015.60 100 11.93 1878 2240 2.82 / 742.55 5 63
4 8 -0.20 218 13.86 448 1354 4.17 / 743.91 5 132
Average= 4.80
(KJ/cycle)

Cycle 158 GMT 10/ 8/2019 10:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.64 67 13.79 604 558 0.56 / 731.41 5 28
2 7 2008.24 100 10.39 3404 3537 4.09 / 734.94 5 29
3 13 1968.24 20 12.35 3332 823 4.92 / 735.77 5 55
4 13 1890.24 20 12.54 3155 791 5.71 / 736.56 5 59
5 13 1691.16 20 12.68 2916 739 6.45 / 737.30 5 67
6 13 1249.52 20 13.00 2279 593 7.04 / 737.89 5 82
7 13 459.56 20 13.64 1124 307 7.35 / 738.20 5 93
8 13 52.56 20 14.09 531 150 7.50 / 738.35 5 92
9 8 -0.04 226 13.94 441 1389 8.89 / 739.73 5 131
Average= 4.80
(KJ/cycle)

Cycle 157 GMT 5/ 8/2019 6:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.88 67 13.83 603 559 0.56 / 727.34 5 28
2 7 988.96 100 11.79 1833 2161 2.72 / 729.50 28 61
3 8 -0.24 223 13.83 437 1348 4.07 / 730.85 5 146
Average= 4.78
(KJ/cycle)

Cycle 156 GMT 31/ 7/2019 7:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.96 67 13.82 618 572 0.57 / 723.19 5 30
2 3 1026.76 1 12.23 2022 25 0.60 / 723.21 5 5
3 7 1016.92 100 11.79 1863 2196 2.79 / 725.41 5 64
4 8 -0.20 226 13.83 439 1372 4.17 / 726.78 5 148
Average= 4.78
(KJ/cycle)

Cycle 155 GMT 26/ 7/2019 8:19:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.60 66 13.81 626 571 0.57 / 719.02 5 24
2 7 1013.36 100 11.78 1887 2223 2.79 / 721.24 5 61
3 8 -0.12 220 13.82 451 1371 4.16 / 722.61 5 131
Average= 4.79
(KJ/cycle)

Cycle 154 GMT 21/ 7/2019 9:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.68 66 13.82 621 566 0.57 / 714.76 5 25
2 7 1010.44 100 11.76 1892 2225 2.79 / 716.99 25 61
3 8 -0.12 235 13.83 450 1463 4.25 / 718.45 5 132
Average= 4.79
(KJ/cycle)

Cycle 153 GMT 16/ 7/2019 10:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.20 66 13.89 597 547 0.55 / 710.56 5 23
2 7 1005.52 100 11.82 1877 2219 2.77 / 712.78 5 61
3 8 -0.24 226 13.82 453 1415 4.18 / 714.20 5 134
Average= 4.79
(KJ/cycle)

Cycle 152 GMT 11/ 7/2019 11:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.60 66 13.86 619 566 0.57 / 706.41 5 25
2 7 998.68 100 11.84 1859 2201 2.77 / 708.61 25 63
3 8 -0.12 233 13.87 436 1409 4.18 / 710.02 5 138
Average= 4.80
(KJ/cycle)

Cycle 151 GMT 6/ 7/2019 12:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.48 66 13.89 615 564 0.56 / 702.30 5 21
2 7 1002.04 100 11.86 1870 2218 2.78 / 704.52 21 63
3 8 -0.16 213 13.89 445 1317 4.10 / 705.84 5 132
Average= 4.80
(KJ/cycle)

Cycle 150 GMT 1/ 7/2019 13:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.56 65 13.99 606 551 0.55 / 698.05 5 17
2 7 1016.84 100 11.97 1903 2278 2.83 / 700.33 5 63
3 8 -0.24 223 13.85 458 1415 4.24 / 701.74 5 144
Average= 4.81
(KJ/cycle)

Cycle 149 GMT 26/ 6/2019 13:56: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 66 13.85 623 569 0.57 / 689.33 5 26
2 3 1023.60 1 12.44 2025 25 0.59 / 689.36 5 5
3 7 2029.76 100 10.65 3445 3669 4.26 / 693.03 5 34
4 13 1978.20 20 12.40 3372 836 5.10 / 693.86 5 54
5 13 1889.88 20 12.54 3190 800 5.90 / 694.66 5 61
6 13 1476.16 20 12.87 2594 668 6.57 / 695.33 5 74
7 13 832.88 20 13.35 1654 442 7.01 / 695.77 5 88
8 13 207.80 20 13.90 758 211 7.22 / 695.98 5 91
9 13 24.64 20 14.15 490 139 7.36 / 696.12 5 91
10 8 -0.12 218 13.93 453 1376 8.73 / 697.50 5 131
Average= 4.81
(KJ/cycle)

Cycle 148 GMT 21/ 6/2019 9:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.16 66 13.85 623 569 0.57 / 685.12 5 20
2 7 1022.56 100 11.85 1910 2263 2.83 / 687.38 20 63
3 8 -0.20 218 13.83 458 1381 4.21 / 688.76 5 132
Average= 4.78
(KJ/cycle)

Cycle 147 GMT 16/ 6/2019 10:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.32 66 13.85 624 570 0.57 / 680.91 5 20
2 7 1012.08 100 11.92 1867 2225 2.80 / 683.14 5 64
3 8 -0.12 223 13.84 457 1410 4.21 / 684.55 5 137
Average= 4.79
(KJ/cycle)

Cycle 146 GMT 11/ 6/2019 11:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.48 66 13.88 623 571 0.57 / 676.75 5 18
2 7 1014.00 100 11.91 1897 2259 2.83 / 679.01 5 63
3 8 -0.24 213 13.85 453 1336 4.17 / 680.34 5 131
Average= 4.79
(KJ/cycle)

Cycle 145 GMT 6/ 6/2019 12:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.56 66 13.87 625 572 0.57 / 672.49 5 24
2 7 1012.68 100 11.92 1888 2250 2.82 / 674.74 5 64
3 8 -0.28 228 13.83 457 1441 4.26 / 676.18 5 145
Average= 4.80
(KJ/cycle)

Cycle 144 GMT 1/ 6/2019 13:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.24 66 13.88 615 563 0.56 / 668.28 5 18
2 7 1005.76 100 11.94 1877 2241 2.80 / 670.52 5 64
3 8 -0.24 216 13.83 466 1392 4.20 / 671.91 5 132
Average= 4.80
(KJ/cycle)

Cycle 143 GMT 27/ 5/2019 14:37:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.40 66 13.93 615 565 0.57 / 664.07 5 19
2 7 1000.24 100 11.97 1857 2223 2.79 / 666.30 19 67
3 8 -0.24 229 13.85 448 1421 4.21 / 667.72 5 138
Average= 4.80
(KJ/cycle)

Cycle 142 GMT 22/ 5/2019 15:34: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.96 66 13.94 603 555 0.55 / 659.85 5 19
2 7 1006.28 101 11.98 1877 2271 2.83 / 662.12 19 66
3 8 -0.36 216 13.84 463 1384 4.21 / 663.51 5 134
Average= 4.81
(KJ/cycle)

Cycle 141 GMT 17/ 5/2019 16:39: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.00 65 14.00 595 541 0.54 / 655.77 5 12
2 7 1014.52 100 12.04 1879 2262 2.80 / 658.03 5 66
3 8 -0.44 209 13.91 435 1265 4.07 / 659.30 5 129
Average= 4.81
(KJ/cycle)

Cycle 140 GMT 12/ 5/2019 17:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.64 66 13.93 612 563 0.56 / 646.96 5 15
2 7 2023.64 100 10.89 3424 3729 4.29 / 650.69 15 37
3 13 1980.48 20 12.47 3376 842 5.13 / 651.53 5 58
4 13 1890.00 20 12.62 3195 806 5.94 / 652.34 5 62
5 13 1452.88 20 12.92 2583 667 6.61 / 653.01 5 76
6 13 899.28 20 13.30 1760 468 7.08 / 653.48 5 90
7 13 344.84 20 13.75 964 265 7.34 / 653.74 5 95
8 13 24.36 20 14.13 492 139 7.48 / 653.88 5 93
9 8 -0.20 212 13.92 457 1349 8.83 / 655.23 5 135
Average= 4.82
(KJ/cycle)

Cycle 139 GMT 7/ 5/2019 13:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.08 66 13.92 602 553 0.55 / 642.72 5 16
2 7 1006.04 100 12.02 1859 2235 2.79 / 644.95 5 64
3 8 -0.28 228 13.84 459 1448 4.24 / 646.40 5 139
Average= 4.79
(KJ/cycle)

Cycle 138 GMT 2/ 5/2019 14:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.08 66 13.94 608 559 0.56 / 638.48 5 15
2 7 1001.16 100 12.04 1852 2230 2.79 / 640.71 15 64
3 8 -0.40 232 13.84 452 1451 4.24 / 642.16 5 135
Average= 4.79
(KJ/cycle)

Cycle 137 GMT 27/ 4/2019 15:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.04 66 13.95 598 551 0.55 / 634.33 5 15
2 7 1002.36 100 12.06 1853 2235 2.79 / 636.56 5 65
3 8 -0.40 218 13.86 450 1360 4.14 / 637.92 5 133
Average= 4.80
(KJ/cycle)

Cycle 136 GMT 22/ 4/2019 16:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.68 66 13.93 612 563 0.56 / 630.16 5 15
2 7 1013.80 100 12.05 1868 2251 2.81 / 632.41 15 64
3 8 -0.24 218 13.86 454 1372 4.19 / 633.78 5 131
Average= 4.80
(KJ/cycle)

Cycle 135 GMT 17/ 4/2019 17:25: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.12 66 13.96 608 560 0.56 / 626.01 5 12
2 7 1003.80 100 12.06 1866 2250 2.81 / 628.26 12 65
3 8 -0.44 213 13.88 450 1330 4.14 / 629.59 5 132
Average= 4.81
(KJ/cycle)

Cycle 134 GMT 12/ 4/2019 18:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.12 66 13.98 592 546 0.55 / 621.80 5 13
2 7 997.24 100 12.07 1861 2246 2.79 / 624.05 13 65
3 8 -0.36 226 13.87 448 1404 4.20 / 625.45 5 141
Average= 4.81
(KJ/cycle)

Cycle 133 GMT 7/ 4/2019 19:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.44 66 13.95 615 566 0.57 / 617.68 5 15
2 7 1005.28 100 12.07 1867 2253 2.82 / 619.94 15 66
3 8 -0.48 217 13.90 437 1318 4.14 / 621.26 5 137
Average= 4.82
(KJ/cycle)

Cycle 132 GMT 2/ 4/2019 20:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.88 65 14.02 597 544 0.54 / 613.51 5 10
2 7 1009.96 100 12.09 1892 2287 2.83 / 615.79 10 67
3 8 -0.48 214 13.90 445 1324 4.16 / 617.12 5 135
Average= 4.82
(KJ/cycle)

Cycle 131 GMT 28/ 3/2019 21:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.88 66 13.98 610 563 0.56 / 604.68 5 12
2 7 2033.48 100 11.05 3450 3812 4.38 / 608.49 12 37
3 13 1983.04 20 12.51 3377 845 5.22 / 609.34 5 55
4 13 1896.80 20 12.63 3213 812 6.03 / 610.15 5 58
5 13 1388.44 20 12.99 2454 638 6.67 / 610.79 5 77
6 13 849.64 20 13.38 1645 440 7.11 / 611.23 5 86
7 13 506.00 20 13.66 1170 320 7.43 / 611.55 5 88
8 13 15.60 20 14.15 470 133 7.56 / 611.68 5 91
9 8 -0.44 206 13.89 449 1285 8.85 / 612.96 5 137
Average= 4.83
(KJ/cycle)

Cycle 130 GMT 23/ 3/2019 17:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.52 66 13.94 614 565 0.56 / 600.42 5 12
2 7 1013.08 100 12.11 1891 2290 2.85 / 602.71 5 64
3 13 15.08 20 14.13 476 135 2.99 / 602.84 5 93
4 8 -0.32 195 13.86 460 1243 4.23 / 604.08 5 135
5 14 -0.44 5 13.68 467 32 4.26 / 604.12 21 143
Average= 4.79
(KJ/cycle)

Cycle 129 GMT 18/ 3/2019 18:17: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.12 65 13.96 610 554 0.55 / 596.08 5 16
2 3 1038.44 1 12.82 2012 26 0.58 / 596.10 5 5
3 7 1026.44 100 12.10 1909 2310 2.89 / 598.41 5 65
4 8 -0.36 228 13.86 455 1438 4.33 / 599.85 5 139
Average= 4.80
(KJ/cycle)

Cycle 128 GMT 13/ 3/2019 19:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.48 66 13.96 605 557 0.56 / 591.89 5 13
2 3 963.68 -1 13.96 605 0 0.00 / 591.89 5 13
3 7 1011.60 100 12.12 1884 2283 2.84 / 594.17 13 65
4 8 -0.44 216 13.87 452 1354 4.19 / 595.52 5 135
Average= 4.80
(KJ/cycle)

Cycle 127 GMT 8/ 3/2019 20:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.24 66 13.97 609 562 0.56 / 587.74 5 10
2 7 981.80 100 12.13 1839 2231 2.79 / 589.97 10 65
3 8 -0.48 216 13.87 453 1357 4.15 / 591.33 5 131
Average= 4.81
(KJ/cycle)

Cycle 126 GMT 3/ 3/2019 21:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.08 66 13.96 607 559 0.56 / 583.56 5 12
2 7 987.28 101 12.16 1839 2259 2.82 / 585.82 12 66
3 13 28.24 20 14.13 476 135 2.95 / 585.95 5 96
4 8 -0.48 190 13.93 440 1165 4.12 / 587.12 5 139
5 14 -0.52 10 13.75 451 62 4.18 / 587.18 13 157
Average= 4.81
(KJ/cycle)

Cycle 125 GMT 26/ 2/2019 22:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.28 66 13.99 601 555 0.55 / 579.44 5 11
2 7 997.68 100 12.16 1837 2234 2.79 / 581.67 11 65
3 8 -0.36 216 13.91 443 1331 4.12 / 583.00 5 129
Average= 4.82
(KJ/cycle)

Cycle 124 GMT 21/ 2/2019 23:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.32 66 13.98 623 575 0.57 / 575.24 5 12
2 7 1008.92 100 12.11 1878 2274 2.85 / 577.51 5 65
3 8 -0.48 220 13.90 447 1367 4.22 / 578.88 5 129
Average= 4.82
(KJ/cycle)

Cycle 123 GMT 17/ 2/2019 0:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.72 65 14.08 587 537 0.54 / 570.95 5 9
2 7 1010.24 100 12.14 1871 2271 2.81 / 573.22 5 66
3 13 13.76 20 14.15 465 132 2.94 / 573.35 5 96
4 8 -0.60 209 13.87 454 1316 4.26 / 574.67 5 137
Average= 4.83
(KJ/cycle)

Cycle 122 GMT 12/ 2/2019 1:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.40 66 14.00 594 549 0.55 / 562.32 5 17
2 7 2019.12 100 11.17 3369 3763 4.31 / 566.09 17 39
3 13 1954.28 20 12.56 3287 826 5.14 / 566.91 5 56
4 13 1862.80 20 12.68 3137 796 5.93 / 567.71 5 62
5 13 1443.92 20 13.00 2532 658 6.59 / 568.37 5 77
6 13 886.96 20 13.36 1708 456 7.05 / 568.82 5 89
7 13 136.00 20 14.03 644 181 7.23 / 569.00 5 90
8 13 27.40 20 14.17 491 139 7.37 / 569.14 5 94
9 8 -0.36 202 13.94 450 1267 8.63 / 570.41 5 131
Average= 4.83
(KJ/cycle)

Cycle 121 GMT 6/ 2/2019 21:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.12 66 13.95 613 564 0.56 / 558.25 5 17
2 7 1004.24 100 12.21 1841 2248 2.81 / 560.50 17 66
3 8 -0.44 209 13.92 439 1277 4.09 / 561.77 5 136
Average= 4.80
(KJ/cycle)

Cycle 120 GMT 1/ 2/2019 22:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.48 66 13.96 599 552 0.55 / 554.18 5 18
2 7 1002.12 100 12.22 1831 2237 2.79 / 556.42 18 66
3 8 -0.36 209 13.93 435 1266 4.06 / 557.69 5 130
Average= 4.81
(KJ/cycle)

Cycle 119 GMT 27/ 1/2019 23:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.68 66 14.00 593 548 0.55 / 550.14 5 19
2 7 988.48 100 12.21 1840 2247 2.79 / 552.38 19 67
3 8 -0.44 204 13.93 439 1248 4.04 / 553.63 5 129
Average= 4.81
(KJ/cycle)

Cycle 118 GMT 23/ 1/2019 0:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.92 66 13.96 600 553 0.55 / 546.12 5 15
2 7 990.12 100 12.21 1850 2259 2.81 / 548.38 15 69
3 8 -0.40 204 13.95 424 1207 4.02 / 549.59 5 130
Average= 4.82
(KJ/cycle)

Cycle 117 GMT 18/ 1/2019 1:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.20 66 13.96 601 554 0.55 / 541.94 5 20
2 7 1001.04 100 12.21 1845 2253 2.81 / 544.19 20 70
3 8 -0.36 221 13.90 449 1379 4.19 / 545.57 5 139
Average= 4.83
(KJ/cycle)

Cycle 116 GMT 13/ 1/2019 2:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.12 66 13.98 604 557 0.56 / 537.94 5 17
2 7 993.92 100 12.22 1827 2233 2.79 / 540.17 17 67
3 8 -0.32 204 13.95 425 1209 4.00 / 541.38 5 132
Average= 4.83
(KJ/cycle)

Cycle 115 GMT 8/ 1/2019 3:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.16 66 14.01 585 541 0.54 / 533.86 5 20
2 7 990.76 100 12.21 1818 2220 2.76 / 536.08 20 67
3 8 -0.24 218 13.93 430 1306 4.07 / 537.38 5 130
Average= 4.84
(KJ/cycle)

Cycle 114 GMT 3/ 1/2019 4:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.04 65 14.08 562 514 0.51 / 529.78 5 17
2 7 1024.88 100 12.15 1884 2289 2.80 / 532.07 5 70
3 8 -0.48 216 13.96 413 1245 4.05 / 533.32 5 130
Average= 4.85
(KJ/cycle)

Cycle 113 GMT 29/12/2018 5:41: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.00 66 13.97 588 542 0.54 / 521.46 5 25
2 7 2008.80 100 11.30 3368 3806 4.35 / 525.26 5 42
3 13 1953.08 20 12.61 3272 825 5.17 / 526.09 5 59
4 13 1855.24 20 12.74 3127 797 5.97 / 526.88 5 64
5 13 1297.60 20 13.12 2303 604 6.57 / 527.49 5 83
6 13 670.68 20 13.57 1374 373 6.95 / 527.86 5 91
7 13 134.00 20 14.07 607 171 7.12 / 528.03 5 92
8 8 -0.28 213 14.00 415 1238 8.36 / 529.27 5 130
Average= 4.86
(KJ/cycle)

Cycle 112 GMT 24/12/2018 1:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.76 66 13.98 593 547 0.55 / 517.43 5 22
2 7 991.00 100 12.25 1830 2242 2.79 / 519.67 22 68
3 8 -0.28 209 13.94 425 1238 4.03 / 520.91 5 134
Average= 4.82
(KJ/cycle)

Cycle 111 GMT 19/12/2018 2:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.00 66 13.97 610 562 0.56 / 513.39 5 22
2 7 997.88 100 12.23 1851 2264 2.83 / 515.65 22 70
3 8 -0.24 209 13.95 423 1233 4.06 / 516.89 5 132
Average= 4.83
(KJ/cycle)

Cycle 110 GMT 14/12/2018 3:59: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.00 66 13.97 602 555 0.56 / 509.19 5 20
2 7 989.16 100 12.24 1845 2258 2.81 / 511.45 20 71
3 8 -0.40 228 13.91 435 1380 4.19 / 512.83 5 130
Average= 4.84
(KJ/cycle)

Cycle 109 GMT 9/12/2018 5: 6: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.68 66 14.00 581 537 0.54 / 505.11 5 26
2 7 981.56 100 12.27 1796 2204 2.74 / 507.31 26 71
3 8 -0.24 219 13.92 434 1323 4.06 / 508.63 5 149
Average= 4.84
(KJ/cycle)

Cycle 108 GMT 4/12/2018 6:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.56 66 13.99 586 541 0.54 / 501.17 5 31
2 7 985.72 100 12.24 1834 2245 2.79 / 503.41 31 71
3 8 -0.20 204 13.98 406 1158 3.94 / 504.57 5 130
Average= 4.85
(KJ/cycle)

Cycle 107 GMT 29/11/2018 7:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.56 66 13.96 599 552 0.55 / 497.13 5 28
2 7 1000.92 100 12.23 1845 2256 2.81 / 499.38 28 70
3 8 -0.20 213 13.95 418 1242 4.05 / 500.63 5 134
Average= 4.86
(KJ/cycle)

Cycle 106 GMT 24/11/2018 8:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.92 66 13.96 589 543 0.54 / 492.99 5 30
2 7 1002.88 100 12.22 1841 2250 2.79 / 495.24 30 71
3 8 -0.28 228 13.94 420 1335 4.13 / 496.58 5 147
Average= 4.87
(KJ/cycle)

Cycle 105 GMT 19/11/2018 9:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.04 65 14.04 583 532 0.53 / 488.95 5 26
2 7 1009.00 100 12.17 1849 2250 2.78 / 491.20 5 69
3 8 -0.32 218 13.96 409 1245 4.03 / 492.45 5 135
Average= 4.88
(KJ/cycle)

Cycle 104 GMT 14/11/2018 10:14:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.08 65 13.95 598 542 0.54 / 480.39 5 31
2 3 1026.84 1 12.85 2001 26 0.57 / 480.42 5 5
3 7 2024.68 100 11.43 3301 3773 4.34 / 484.19 5 42
4 13 1957.00 20 12.68 3230 819 5.16 / 485.01 5 59
5 13 1859.72 20 12.77 3084 788 5.95 / 485.80 5 67
6 13 1424.68 20 13.07 2480 648 6.60 / 486.44 5 81
7 13 855.40 20 13.47 1626 438 7.03 / 486.88 5 89
8 13 96.76 20 14.13 556 157 7.19 / 487.04 5 93
9 8 -0.08 235 13.97 421 1382 8.57 / 488.42 5 130
Average= 4.88
(KJ/cycle)

Cycle 103 GMT 9/11/2018 6:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.12 66 13.95 590 543 0.54 / 476.31 5 34
2 7 1004.88 100 12.28 1831 2248 2.79 / 478.56 34 68
3 8 -0.12 219 13.95 421 1286 4.08 / 479.85 5 133
Average= 4.85
(KJ/cycle)

Cycle 102 GMT 4/11/2018 7:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.08 66 13.94 594 547 0.55 / 472.25 5 33
2 7 999.20 100 12.29 1823 2240 2.79 / 474.49 5 71
3 8 -0.12 219 13.95 418 1277 4.06 / 475.77 5 138
Average= 4.85
(KJ/cycle)

Cycle 101 GMT 30/10/2018 8:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.04 66 13.96 594 547 0.55 / 468.11 5 32
2 7 991.36 100 12.28 1835 2253 2.80 / 470.36 32 70
3 8 -0.12 228 13.94 423 1344 4.15 / 471.71 5 137
Average= 4.86
(KJ/cycle)

Cycle 100 GMT 25/10/2018 9:34:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.72 66 13.93 612 563 0.56 / 463.91 5 34
2 7 1011.72 100 12.27 1876 2302 2.86 / 466.21 5 70
3 8 -0.20 230 13.93 422 1352 4.22 / 467.56 5 133
Average= 4.87
(KJ/cycle)

Cycle 99 GMT 20/10/2018 10:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.72 66 13.97 591 545 0.54 / 459.72 5 38
2 7 1004.32 100 12.26 1857 2277 2.82 / 461.99 5 73
3 8 -0.16 231 13.94 420 1352 4.17 / 463.34 5 129
Average= 4.88
(KJ/cycle)

Cycle 98 GMT 15/10/2018 11:42: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.64 66 13.96 597 550 0.55 / 455.63 5 34
2 7 1013.28 100 12.26 1844 2261 2.81 / 457.89 5 68
3 8 -0.16 218 13.96 420 1278 4.09 / 459.17 5 142
Average= 4.88
(KJ/cycle)

Cycle 97 GMT 10/10/2018 12:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.52 66 13.97 594 548 0.55 / 451.55 5 35
2 7 1006.20 100 12.24 1857 2273 2.82 / 453.82 35 71
3 8 -0.20 220 13.97 411 1263 4.08 / 455.08 5 140
Average= 4.89
(KJ/cycle)

Cycle 96 GMT 5/10/2018 13:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.48 65 13.99 595 541 0.54 / 447.46 5 32
2 7 1016.28 100 12.20 1872 2284 2.82 / 449.74 5 69
3 8 -0.20 216 13.96 417 1257 4.08 / 451.00 5 137
Average= 4.90
(KJ/cycle)

Cycle 95 GMT 30/ 9/2018 14:41: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.92 65 13.94 610 553 0.55 / 438.82 5 38
2 7 2032.12 100 11.46 3397 3893 4.45 / 442.71 5 43
3 13 1968.96 20 12.67 3251 824 5.27 / 443.54 5 58
4 13 1669.08 20 12.96 2809 728 6.00 / 444.26 5 70
5 13 1468.88 20 13.10 2522 661 6.66 / 444.92 5 79
6 13 786.40 20 13.54 1537 416 7.07 / 445.34 5 90
7 13 216.00 20 14.01 737 207 7.28 / 445.55 5 94
8 8 0.00 235 13.96 417 1368 8.65 / 446.92 5 129
Average= 4.91
(KJ/cycle)

Cycle 94 GMT 25/ 9/2018 10:47:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.96 65 13.98 583 530 0.53 / 434.73 5 39
2 7 1005.88 100 12.33 1847 2277 2.81 / 437.01 5 71
3 8 -0.20 216 13.96 416 1254 4.06 / 438.27 5 129
Average= 4.87
(KJ/cycle)

Cycle 93 GMT 20/ 9/2018 11:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.68 65 13.98 580 527 0.53 / 430.78 5 37
2 7 1004.04 100 12.35 1811 2237 2.76 / 433.02 37 70
3 8 -0.12 211 13.99 401 1184 3.95 / 434.20 5 137
Average= 4.88
(KJ/cycle)

Cycle 92 GMT 15/ 9/2018 12:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.04 65 13.97 590 536 0.54 / 426.81 5 37
2 7 994.20 100 12.35 1805 2229 2.76 / 429.04 37 71
3 8 -0.04 218 13.98 401 1222 3.99 / 430.26 5 143
Average= 4.89
(KJ/cycle)

Cycle 91 GMT 10/ 9/2018 14: 2: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.56 65 13.98 570 518 0.52 / 422.76 5 41
2 7 989.04 100 12.37 1796 2222 2.74 / 424.98 41 74
3 8 -0.08 235 13.97 392 1287 4.03 / 426.27 5 131
Average= 4.90
(KJ/cycle)

Cycle 90 GMT 5/ 9/2018 15: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.48 65 13.95 597 541 0.54 / 418.79 5 41
2 7 997.24 100 12.35 1817 2244 2.79 / 421.04 5 74
3 8 -0.08 220 13.98 393 1209 3.99 / 422.24 5 130
Average= 4.91
(KJ/cycle)

Cycle 89 GMT 31/ 8/2018 16:11: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.20 65 13.99 560 509 0.51 / 414.75 5 42
2 7 987.92 100 12.38 1805 2235 2.74 / 416.98 42 73
3 8 -0.08 225 13.96 403 1266 4.01 / 418.25 5 137
Average= 4.92
(KJ/cycle)

Cycle 88 GMT 26/ 8/2018 17:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.60 65 13.99 578 526 0.53 / 410.83 5 39
2 7 994.32 100 12.36 1813 2241 2.77 / 413.07 39 73
3 8 -0.16 220 14.00 380 1170 3.94 / 414.24 5 132
Average= 4.93
(KJ/cycle)

Cycle 87 GMT 21/ 8/2018 18:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.88 65 14.07 556 508 0.51 / 406.78 5 33
2 7 993.48 100 12.35 1806 2230 2.74 / 409.01 33 74
3 8 -0.28 234 13.96 397 1297 4.04 / 410.30 5 132
Average= 4.94
(KJ/cycle)

Cycle 86 GMT 16/ 8/2018 19:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.48 65 13.98 572 520 0.52 / 398.48 5 38
2 7 2008.64 100 11.62 3323 3861 4.38 / 402.34 38 47
3 13 1946.72 20 12.78 3161 808 5.19 / 403.15 5 60
4 13 1751.20 20 12.98 2922 759 5.95 / 403.91 5 71
5 13 1209.76 20 13.32 2132 568 6.52 / 404.47 5 88
6 13 566.92 20 13.74 1199 329 6.85 / 404.80 5 93
7 13 58.36 20 14.19 482 137 6.98 / 404.94 5 94
8 8 -0.08 239 13.99 397 1327 8.31 / 406.27 5 140
Average= 4.95
(KJ/cycle)

Cycle 85 GMT 11/ 8/2018 15:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.00 65 14.02 557 508 0.51 / 394.50 5 39
2 7 986.96 100 12.43 1795 2231 2.74 / 396.73 39 73
3 8 -0.16 228 13.98 385 1227 3.97 / 397.96 5 134
Average= 4.91
(KJ/cycle)

Cycle 84 GMT 6/ 8/2018 16:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.80 65 14.00 564 513 0.51 / 390.51 5 39
2 7 989.12 100 12.45 1801 2242 2.76 / 392.76 39 75
3 8 -0.16 229 13.98 386 1236 3.99 / 393.99 5 130
Average= 4.92
(KJ/cycle)

Cycle 83 GMT 1/ 8/2018 17:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.16 65 13.99 575 523 0.52 / 386.50 5 38
2 7 991.52 100 12.45 1807 2250 2.77 / 388.75 38 74
3 8 -0.32 226 13.98 397 1254 4.03 / 390.00 5 140
Average= 4.94
(KJ/cycle)

Cycle 82 GMT 27/ 7/2018 18:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.96 65 14.02 559 509 0.51 / 382.48 5 35
2 7 979.04 100 12.48 1788 2231 2.74 / 384.71 35 74
3 8 -0.16 223 13.97 407 1268 4.01 / 385.97 5 133
Average= 4.95
(KJ/cycle)

Cycle 81 GMT 22/ 7/2018 19:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.32 65 14.01 571 520 0.52 / 378.43 5 34
2 7 1007.28 100 12.49 1837 2294 2.81 / 380.72 5 74
3 8 -0.32 235 14.01 377 1241 4.06 / 381.97 5 135
Average= 4.96
(KJ/cycle)

Cycle 80 GMT 17/ 7/2018 20:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.40 65 14.03 564 514 0.51 / 374.39 5 32
2 7 1007.40 100 12.49 1823 2277 2.79 / 376.67 5 74
3 8 -0.16 225 14.01 394 1242 4.03 / 377.91 5 129
Average= 4.97
(KJ/cycle)

Cycle 79 GMT 12/ 7/2018 21:56: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.88 65 14.03 579 528 0.53 / 370.30 5 36
2 7 1002.96 100 12.50 1824 2280 2.81 / 372.58 36 75
3 8 -0.12 235 14.01 393 1294 4.10 / 373.88 5 146
Average= 4.99
(KJ/cycle)

Cycle 78 GMT 7/ 7/2018 23: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.40 65 14.12 537 493 0.49 / 366.30 5 31
2 7 1001.64 100 12.54 1830 2295 2.79 / 368.59 5 74
3 8 -0.40 213 14.02 396 1183 3.97 / 369.77 5 133
Average= 5.00
(KJ/cycle)

Cycle 77 GMT 2/ 7/2018 23:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.04 65 14.05 554 506 0.51 / 358.07 5 32
2 7 2027.52 101 11.83 3318 3964 4.47 / 362.03 5 48
3 13 1962.48 20 12.85 3202 823 5.29 / 362.85 5 61
4 13 1867.52 20 12.94 3089 799 6.09 / 363.65 5 69
5 13 1210.84 20 13.40 2129 571 6.66 / 364.22 5 89
6 13 461.24 20 13.89 1053 293 6.96 / 364.52 5 97
7 13 75.24 20 14.23 505 144 7.10 / 364.66 5 95
8 8 -0.04 211 14.08 385 1144 8.24 / 365.80 5 132
Average= 5.01
(KJ/cycle)

Cycle 76 GMT 27/ 6/2018 19:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.96 65 14.07 546 499 0.50 / 354.10 5 34
2 7 992.88 100 12.59 1808 2276 2.78 / 356.37 34 76
3 8 -0.16 220 14.04 385 1189 3.96 / 357.56 5 131
Average= 4.97
(KJ/cycle)

Cycle 75 GMT 22/ 6/2018 20:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.00 65 14.05 564 515 0.52 / 350.22 5 30
2 7 1005.72 100 12.61 1804 2275 2.79 / 352.50 30 74
3 8 -0.16 211 14.07 370 1098 3.89 / 353.60 5 135
Average= 4.98
(KJ/cycle)

Cycle 74 GMT 17/ 6/2018 22: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.40 65 14.07 556 508 0.51 / 346.32 5 31
2 7 983.44 100 12.67 1767 2239 2.75 / 348.56 31 74
3 8 -0.24 219 14.08 372 1147 3.89 / 349.71 5 132
Average= 5.00
(KJ/cycle)

Cycle 73 GMT 12/ 6/2018 23:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.20 65 14.08 545 499 0.50 / 342.40 5 31
2 7 980.80 100 12.69 1774 2251 2.75 / 344.65 31 77
3 8 -0.28 221 14.07 374 1163 3.91 / 345.81 5 137
Average= 5.01
(KJ/cycle)

Cycle 72 GMT 8/ 6/2018 0:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.72 65 14.08 552 505 0.51 / 338.43 5 28
2 7 1009.44 100 12.70 1823 2315 2.82 / 340.75 5 77
3 8 -0.40 225 14.07 364 1152 3.97 / 341.90 5 137
Average= 5.03
(KJ/cycle)

Cycle 71 GMT 3/ 6/2018 1:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.88 65 14.07 551 504 0.50 / 334.45 5 29
2 7 1004.08 100 12.72 1793 2281 2.78 / 336.73 29 76
3 8 -0.20 226 14.08 377 1200 3.98 / 337.93 5 132
Average= 5.04
(KJ/cycle)

Cycle 70 GMT 29/ 5/2018 2:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.20 65 14.12 547 502 0.50 / 330.51 5 27
2 7 999.20 100 12.77 1778 2271 2.77 / 332.78 27 75
3 8 -0.28 219 14.07 377 1162 3.93 / 333.94 5 131
Average= 5.06
(KJ/cycle)

Cycle 69 GMT 24/ 5/2018 3:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.68 64 14.19 529 480 0.48 / 326.57 5 21
2 7 1012.16 100 12.75 1842 2349 2.83 / 328.91 5 77
3 8 -0.36 207 14.11 375 1095 3.92 / 330.01 5 134
Average= 5.08
(KJ/cycle)

Cycle 68 GMT 19/ 5/2018 4:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.08 65 14.15 534 491 0.49 / 318.51 5 23
2 7 2007.52 100 12.09 3231 3906 4.40 / 322.41 5 49
3 13 1938.32 20 12.99 3100 805 5.20 / 323.22 5 60
4 13 1642.84 20 13.24 2717 719 5.92 / 323.94 5 74
5 13 1112.52 20 13.54 1958 530 6.45 / 324.47 5 90
6 13 553.96 20 13.88 1169 325 6.78 / 324.79 5 93
7 13 51.24 20 14.31 454 130 6.91 / 324.92 5 96
8 8 -0.16 218 14.12 378 1164 8.07 / 326.09 5 132
Average= 5.10
(KJ/cycle)

Cycle 67 GMT 14/ 5/2018 0:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.44 65 14.14 517 475 0.48 / 314.63 5 21
2 7 1009.48 100 12.75 1823 2324 2.80 / 316.95 5 76
3 8 -0.24 199 14.12 376 1057 3.86 / 318.01 5 130
4 14 -0.32 1 14.00 387 5 3.86 / 318.01 9 72
Average= 5.05
(KJ/cycle)

Cycle 66 GMT 9/ 5/2018 1:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.92 65 14.14 540 496 0.50 / 310.78 5 20
2 7 999.44 100 12.78 1773 2266 2.76 / 313.04 20 75
3 8 -0.36 219 14.11 360 1112 3.87 / 314.15 5 148
Average= 5.07
(KJ/cycle)

Cycle 65 GMT 4/ 5/2018 2:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.76 65 14.16 528 486 0.49 / 306.84 5 22
2 7 1002.32 100 12.77 1803 2302 2.79 / 309.14 22 76
3 8 -0.32 219 14.12 368 1138 3.93 / 310.28 5 137
Average= 5.09
(KJ/cycle)

Cycle 64 GMT 29/ 4/2018 3:50: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.64 65 14.17 518 477 0.48 / 303.02 5 22
2 7 1000.96 100 12.79 1780 2277 2.75 / 305.30 22 76
3 8 -0.32 204 14.14 365 1053 3.81 / 306.35 5 133
Average= 5.11
(KJ/cycle)

Cycle 63 GMT 24/ 4/2018 4:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.80 65 14.18 515 475 0.47 / 299.20 5 21
2 7 999.64 100 12.81 1793 2297 2.77 / 301.49 21 77
3 8 -0.28 205 14.12 364 1054 3.83 / 302.55 5 132
Average= 5.13
(KJ/cycle)

Cycle 62 GMT 19/ 4/2018 6: 5: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.80 65 14.18 518 477 0.48 / 295.39 5 19
2 7 1002.92 100 12.83 1783 2288 2.77 / 297.68 19 74
3 8 -0.52 213 14.15 346 1043 3.81 / 298.72 5 132
Average= 5.15
(KJ/cycle)

Cycle 61 GMT 14/ 4/2018 7:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.40 65 14.18 521 480 0.48 / 291.60 5 22
2 7 1006.92 100 12.84 1773 2277 2.76 / 293.88 5 75
3 8 -0.28 211 14.17 347 1037 3.79 / 294.91 5 129
Average= 5.17
(KJ/cycle)

Cycle 60 GMT 9/ 4/2018 8:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.00 64 14.27 499 456 0.46 / 287.80 5 15
2 7 1009.60 100 12.81 1796 2301 2.76 / 290.10 5 74
3 8 -0.32 202 14.16 355 1015 3.77 / 291.12 5 131
Average= 5.20
(KJ/cycle)

Cycle 59 GMT 4/ 4/2018 9: 5: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.56 65 14.20 489 451 0.45 / 279.85 5 21
2 7 2007.32 100 12.06 3264 3936 4.39 / 283.79 21 50
3 13 1940.68 20 12.96 3153 817 5.20 / 284.60 5 64
4 13 1743.76 20 13.21 2871 759 5.96 / 285.36 5 72
5 13 1078.64 20 13.58 1909 518 6.48 / 285.88 5 89
6 13 532.52 20 13.94 1149 320 6.80 / 286.20 5 97
7 13 22.24 20 14.39 403 116 6.92 / 286.32 5 94
8 8 -0.12 204 14.18 356 1030 7.95 / 287.35 5 131
Average= 5.22
(KJ/cycle)

Cycle 58 GMT 30/ 3/2018 5:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.80 65 14.23 488 451 0.45 / 276.13 5 18
2 7 990.72 100 12.84 1781 2287 2.74 / 278.42 18 75
3 8 -0.32 202 14.18 342 980 3.72 / 279.40 5 133
Average= 5.17
(KJ/cycle)

Cycle 57 GMT 25/ 3/2018 6:26: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.40 65 14.25 491 455 0.45 / 272.43 5 18
2 7 989.92 100 12.85 1769 2273 2.73 / 274.70 18 78
3 8 -0.40 205 14.20 336 978 3.71 / 275.68 5 132
Average= 5.20
(KJ/cycle)

Cycle 56 GMT 20/ 3/2018 7:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.20 65 14.23 507 469 0.47 / 268.77 5 15
2 7 1011.32 100 12.86 1768 2274 2.74 / 271.05 5 77
3 8 -0.36 199 14.23 326 923 3.67 / 271.97 5 130
4 14 -0.24 1 14.12 345 5 3.67 / 271.97 8 75
Average= 5.23
(KJ/cycle)

Cycle 55 GMT 15/ 3/2018 8:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.40 65 14.26 492 456 0.46 / 264.99 5 15
2 7 1001.32 100 12.91 1784 2303 2.76 / 267.29 15 77
3 8 -0.40 206 14.20 347 1015 3.77 / 268.30 5 135
Average= 5.26
(KJ/cycle)

Cycle 54 GMT 10/ 3/2018 9:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.72 65 14.27 483 448 0.45 / 261.23 5 16
2 7 998.84 100 12.95 1769 2291 2.74 / 263.52 16 78
3 8 -0.36 214 14.22 332 1010 3.75 / 264.53 5 138
Average= 5.29
(KJ/cycle)

Cycle 53 GMT 5/ 3/2018 10:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.68 65 14.28 486 451 0.45 / 257.54 5 20
2 7 996.56 100 12.98 1766 2292 2.74 / 259.83 20 79
3 8 -0.36 209 14.24 320 952 3.70 / 260.78 5 134
Average= 5.32
(KJ/cycle)

Cycle 52 GMT 28/ 2/2018 11:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.24 65 14.24 498 461 0.46 / 253.91 5 18
2 7 1000.68 100 13.03 1747 2276 2.74 / 256.19 18 79
3 8 -0.40 200 14.24 314 894 3.63 / 257.09 5 130
Average= 5.36
(KJ/cycle)

Cycle 51 GMT 23/ 2/2018 13: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.00 64 14.36 480 441 0.44 / 250.14 5 16
2 7 992.24 100 13.06 1742 2275 2.72 / 252.42 16 78
3 8 -0.68 220 14.21 331 1035 3.75 / 253.45 5 137
Average= 5.39
(KJ/cycle)

Cycle 50 GMT 18/ 2/2018 13:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.84 65 14.25 490 454 0.45 / 242.35 5 21
2 7 2029.60 100 12.28 3269 4014 4.47 / 246.37 21 53
3 13 1948.88 20 13.12 3150 827 5.29 / 247.19 5 66
4 13 1636.08 20 13.42 2693 723 6.02 / 247.92 5 80
5 13 1075.68 20 13.73 1861 511 6.53 / 248.43 5 93
6 13 325.28 20 14.20 819 233 6.76 / 248.66 5 98
7 13 16.08 20 14.49 366 106 6.87 / 248.77 5 97
8 8 -0.08 199 14.26 328 931 7.80 / 249.70 5 135
9 14 -0.20 1 14.17 349 5 7.80 / 249.70 7 74
Average= 5.43
(KJ/cycle)

Cycle 49 GMT 13/ 2/2018 9:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.92 65 14.26 506 469 0.47 / 238.65 5 20
2 7 993.84 100 13.08 1745 2282 2.75 / 240.93 20 77
3 8 -0.32 204 14.23 334 970 3.72 / 241.90 5 133
Average= 5.38
(KJ/cycle)

Cycle 48 GMT 8/ 2/2018 11: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.16 65 14.25 509 471 0.47 / 234.90 5 20
2 7 994.96 100 13.11 1748 2292 2.76 / 237.19 20 77
3 8 -0.36 213 14.24 327 992 3.75 / 238.18 5 129
Average= 5.41
(KJ/cycle)

Cycle 47 GMT 3/ 2/2018 12:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.28 65 14.27 502 466 0.47 / 231.10 5 17
2 7 1008.52 100 13.11 1787 2343 2.81 / 233.44 17 79
3 8 -0.36 211 14.25 326 980 3.79 / 234.42 5 134
Average= 5.45
(KJ/cycle)

Cycle 46 GMT 29/ 1/2018 13:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.04 65 14.28 503 467 0.47 / 227.32 5 21
2 7 997.08 100 13.14 1766 2321 2.79 / 229.64 21 81
3 8 -0.36 214 14.25 326 994 3.78 / 230.64 5 141
Average= 5.49
(KJ/cycle)

Cycle 45 GMT 24/ 1/2018 14:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.88 65 14.32 472 439 0.44 / 223.61 5 18
2 7 1002.76 101 13.12 1764 2338 2.78 / 225.95 5 78
3 8 -0.40 187 14.29 316 844 3.62 / 226.79 5 133
4 14 -0.40 13 14.16 330 61 3.68 / 226.85 6 127
Average= 5.53
(KJ/cycle)

Cycle 44 GMT 19/ 1/2018 15:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 65 14.30 480 446 0.45 / 219.87 5 23
2 7 1005.88 100 13.19 1767 2331 2.78 / 222.20 23 77
3 8 -0.32 219 14.27 312 975 3.75 / 223.17 5 137
Average= 5.58
(KJ/cycle)

Cycle 43 GMT 14/ 1/2018 16:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.88 65 14.28 497 461 0.46 / 216.14 5 23
2 7 997.16 100 13.21 1750 2312 2.77 / 218.45 23 78
3 8 -0.32 216 14.27 314 968 3.74 / 219.42 5 136
Average= 5.63
(KJ/cycle)

Cycle 42 GMT 9/ 1/2018 18: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.00 64 14.34 508 466 0.47 / 212.40 5 19
2 7 1009.72 100 13.20 1778 2347 2.81 / 214.75 5 80
3 8 -0.48 209 14.29 312 932 3.75 / 215.68 5 129
Average= 5.68
(KJ/cycle)

Cycle 41 GMT 4/ 1/2018 18:56: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.32 65 14.30 475 442 0.44 / 204.54 5 23
2 7 2011.08 100 12.46 3205 3993 4.43 / 208.53 23 53
3 13 1945.04 20 13.24 3150 834 5.27 / 209.37 5 69
4 13 1530.84 20 13.57 2561 695 5.96 / 210.06 5 83
5 13 982.88 20 13.88 1733 481 6.45 / 210.54 5 93
6 13 533.52 20 14.14 1106 313 6.76 / 210.85 5 94
7 13 17.48 20 14.54 362 105 6.86 / 210.96 5 97
8 8 -0.36 214 14.27 319 974 7.84 / 211.93 5 129
Average= 5.73
(KJ/cycle)

Cycle 40 GMT 30/12/2017 15: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.32 65 14.29 483 449 0.45 / 200.83 5 27
2 7 990.40 100 13.27 1740 2309 2.76 / 203.14 27 79
3 8 -0.24 214 14.29 313 957 3.71 / 204.10 5 136
Average= 5.67
(KJ/cycle)

Cycle 39 GMT 25/12/2017 16:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.20 65 14.29 470 437 0.44 / 197.16 5 30
2 7 980.48 100 13.29 1717 2282 2.72 / 199.44 30 81
3 8 -0.24 209 14.29 314 938 3.66 / 200.38 5 137
Average= 5.73
(KJ/cycle)

Cycle 38 GMT 20/12/2017 17:25: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.72 65 14.27 475 441 0.44 / 193.50 5 33
2 7 992.08 100 13.27 1752 2325 2.77 / 195.82 33 80
3 8 -0.24 207 14.30 305 903 3.67 / 196.73 5 132
Average= 5.79
(KJ/cycle)

Cycle 37 GMT 15/12/2017 18:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.92 65 14.29 472 438 0.44 / 189.85 5 30
2 7 991.32 100 13.28 1747 2320 2.76 / 192.17 30 80
3 8 -0.20 199 14.31 309 880 3.64 / 193.05 5 130
4 14 -0.24 1 14.22 329 5 3.64 / 193.06 8 76
Average= 5.85
(KJ/cycle)

Cycle 36 GMT 10/12/2017 19:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.64 65 14.29 475 441 0.44 / 186.22 5 29
2 7 999.32 100 13.29 1740 2312 2.75 / 188.53 29 78
3 8 -0.16 200 14.31 309 884 3.64 / 189.41 5 131
Average= 5.92
(KJ/cycle)

Cycle 35 GMT 5/12/2017 21: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.20 65 14.29 479 445 0.44 / 182.58 5 30
2 7 986.72 100 13.31 1716 2284 2.73 / 184.86 30 79
3 8 -0.24 190 14.31 319 867 3.60 / 185.73 5 133
4 14 -0.24 10 14.21 319 45 3.64 / 185.78 5 136
Average= 5.99
(KJ/cycle)

Cycle 34 GMT 30/11/2017 22:15:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.28 65 14.27 488 453 0.45 / 178.92 5 31
2 7 999.24 100 13.31 1728 2300 2.75 / 181.22 31 77
3 8 -0.28 194 14.31 319 886 3.64 / 182.11 5 132
4 14 -0.24 6 14.22 320 27 3.67 / 182.13 8 126
Average= 6.07
(KJ/cycle)

Cycle 33 GMT 25/11/2017 23:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.72 64 14.33 480 440 0.44 / 175.19 5 26
2 7 1003.56 100 13.32 1775 2364 2.80 / 177.55 26 79
3 8 -0.20 194 14.31 320 888 3.69 / 178.44 5 131
4 14 -0.24 6 14.22 322 27 3.72 / 178.47 9 131
Average= 6.15
(KJ/cycle)

Cycle 32 GMT 21/11/2017 0:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 65 14.29 482 448 0.45 / 167.51 5 28
2 7 2008.56 100 12.43 3199 3976 4.42 / 171.48 28 47
3 13 1937.84 20 13.26 3130 830 5.25 / 172.31 5 65
4 13 1531.64 20 13.59 2551 693 5.95 / 173.01 5 81
5 13 910.08 20 13.94 1634 456 6.40 / 173.46 5 91
6 13 478.48 20 14.21 1032 293 6.70 / 173.76 5 96
7 8 0.00 218 14.32 318 993 7.69 / 174.75 5 131
Average= 6.24
(KJ/cycle)

Cycle 31 GMT 15/11/2017 20: 2: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.56 65 14.29 478 444 0.44 / 163.83 5 28
2 7 982.64 100 13.34 1736 2316 2.76 / 166.14 28 79
3 8 -0.12 194 14.32 320 889 3.65 / 167.03 5 138
4 14 -0.24 6 14.22 319 27 3.68 / 167.06 9 144
Average= 6.19
(KJ/cycle)

Cycle 30 GMT 10/11/2017 21: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.52 65 14.28 477 443 0.44 / 160.11 5 31
2 7 989.52 100 13.34 1753 2339 2.78 / 162.45 31 78
3 8 -0.20 192 14.31 326 896 3.68 / 163.35 5 133
4 14 -0.24 8 14.23 322 37 3.71 / 163.38 8 136
Average= 6.28
(KJ/cycle)

Cycle 29 GMT 5/11/2017 22:18:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.44 65 14.27 481 446 0.45 / 156.40 5 32
2 7 991.08 100 13.35 1753 2340 2.79 / 158.74 32 78
3 8 -0.20 195 14.32 323 902 3.69 / 159.65 5 137
4 14 -0.24 5 14.22 327 23 3.71 / 159.67 10 144
Average= 6.39
(KJ/cycle)

Cycle 28 GMT 31/10/2017 23:34: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.48 65 14.29 473 439 0.44 / 152.68 5 30
2 7 989.68 100 13.35 1756 2344 2.78 / 155.02 30 80
3 8 -0.12 193 14.31 327 903 3.69 / 155.93 5 133
4 14 -0.04 7 14.21 321 32 3.72 / 155.96 7 143
Average= 6.50
(KJ/cycle)

Cycle 27 GMT 27/10/2017 0:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.04 65 14.30 476 442 0.44 / 149.00 5 30
2 7 983.00 100 13.36 1741 2326 2.77 / 151.33 30 79
3 8 -0.12 190 14.33 319 869 3.64 / 152.19 5 142
4 14 -0.16 10 14.22 318 45 3.68 / 152.24 5 147
Average= 6.62
(KJ/cycle)

Cycle 26 GMT 22/10/2017 1:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.20 65 14.30 468 435 0.44 / 145.31 5 30
2 7 988.08 100 13.37 1750 2340 2.77 / 147.65 30 80
3 8 -0.08 193 14.33 318 879 3.65 / 148.53 5 129
4 14 -0.20 7 14.23 319 32 3.69 / 148.56 7 141
Average= 6.75
(KJ/cycle)

Cycle 25 GMT 17/10/2017 3: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.28 64 14.30 489 448 0.45 / 141.59 5 30
2 3 1026.16 1 14.42 1939 28 0.48 / 141.62 5 5
3 7 1006.92 100 13.37 1769 2365 2.84 / 143.98 5 79
4 8 -0.20 190 14.35 310 845 3.69 / 144.83 5 132
5 14 -0.20 10 14.23 315 45 3.73 / 144.87 16 146
Average= 6.90
(KJ/cycle)

Cycle 24 GMT 12/10/2017 4:14:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.20 64 14.35 470 432 0.43 / 137.85 5 26
2 7 1004.44 100 13.41 1764 2366 2.80 / 140.22 5 80
3 8 0.00 190 14.32 323 879 3.68 / 141.10 5 130
4 14 -0.24 10 14.22 318 45 3.72 / 141.14 7 142
Average= 7.06
(KJ/cycle)

Cycle 23 GMT 7/10/2017 5: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.56 65 14.33 478 445 0.45 / 130.06 5 29
2 7 2016.56 100 12.40 3277 4063 4.51 / 134.12 29 48
3 13 1949.44 20 13.24 3168 839 5.35 / 134.96 5 64
4 13 1531.48 20 13.62 2542 692 6.04 / 135.65 5 78
5 13 1002.16 20 13.90 1773 493 6.53 / 136.15 5 91
6 13 460.24 20 14.24 1012 288 6.82 / 136.43 5 97
7 8 -0.04 218 14.34 315 985 7.81 / 137.42 5 149
Average= 7.23
(KJ/cycle)

Cycle 22 GMT 2/10/2017 1: 3:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.40 64 14.35 469 431 0.43 / 126.34 5 29
2 7 992.80 100 13.39 1754 2349 2.78 / 128.69 29 79
3 8 -0.24 183 14.33 322 844 3.62 / 129.54 5 141
4 14 -0.24 17 14.22 319 77 3.70 / 129.61 6 140
Average= 7.20
(KJ/cycle)

Cycle 21 GMT 27/ 9/2017 2:10: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.80 64 14.31 474 434 0.43 / 122.62 5 31
2 7 1001.88 100 13.39 1769 2369 2.80 / 124.99 31 80
3 8 -0.16 190 14.33 322 877 3.68 / 125.87 5 129
4 14 -0.24 10 14.23 315 45 3.72 / 125.91 11 150
Average= 7.41
(KJ/cycle)

Cycle 20 GMT 22/ 9/2017 3:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.24 64 14.33 465 426 0.43 / 118.92 5 33
2 7 1001.32 100 13.40 1763 2362 2.79 / 121.29 33 81
3 8 -0.12 166 14.36 315 751 3.54 / 122.04 5 132
4 14 -0.16 34 14.22 313 151 3.69 / 122.19 5 151
Average= 7.64
(KJ/cycle)

Cycle 19 GMT 17/ 9/2017 4:31:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.20 64 14.35 468 430 0.43 / 115.26 5 31
2 7 990.68 100 13.41 1744 2339 2.77 / 117.60 31 79
3 8 -0.24 190 14.34 314 856 3.62 / 118.45 5 135
4 14 -0.28 10 14.23 313 45 3.67 / 118.50 6 138
Average= 7.90
(KJ/cycle)

Cycle 18 GMT 12/ 9/2017 5:46: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 64 14.35 460 422 0.42 / 111.59 5 30
2 7 991.80 100 13.42 1737 2331 2.75 / 113.93 30 79
3 8 -0.12 190 14.34 315 858 3.61 / 114.78 5 136
4 14 -0.16 10 14.23 312 44 3.66 / 114.83 6 135
Average= 8.20
(KJ/cycle)

Cycle 17 GMT 7/ 9/2017 6:56: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.48 64 14.33 494 453 0.45 / 107.94 5 30
2 7 994.72 100 13.43 1747 2346 2.80 / 110.29 30 79
3 8 -0.08 193 14.36 309 856 3.66 / 111.14 5 130
4 14 -0.16 7 14.24 309 31 3.69 / 111.17 7 145
Average= 8.55
(KJ/cycle)

Cycle 16 GMT 2/ 9/2017 8: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.24 64 14.35 474 435 0.44 / 104.20 5 29
2 7 995.72 100 13.45 1757 2363 2.80 / 106.56 29 80
3 8 -0.20 192 14.34 322 887 3.69 / 107.45 5 132
4 14 -0.16 8 14.24 322 37 3.72 / 107.49 10 139
Average= 8.96
(KJ/cycle)

Cycle 15 GMT 28/ 8/2017 9:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.48 64 14.44 462 427 0.43 / 100.47 5 25
2 7 999.84 100 13.49 1757 2370 2.80 / 102.84 25 79
3 8 -0.28 190 14.36 322 879 3.68 / 103.72 5 139
4 14 -0.36 10 14.24 325 46 3.72 / 103.76 10 146
Average= 9.43
(KJ/cycle)

Cycle 14 GMT 23/ 8/2017 10: 9: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.40 64 14.46 467 432 0.43 / 92.70 5 24
2 3 1021.60 1 14.49 1918 28 0.46 / 92.73 5 5
3 7 2011.76 100 12.60 3210 4045 4.50 / 96.78 5 44
4 13 1936.64 20 13.35 3121 833 5.34 / 97.61 5 63
5 13 1526.00 20 13.66 2538 693 6.03 / 98.30 5 78
6 13 985.76 20 13.95 1750 488 6.52 / 98.79 5 92
7 13 330.36 20 14.37 835 240 6.76 / 99.03 5 96
8 13 26.08 20 14.69 372 109 6.87 / 99.14 5 95
9 8 -0.24 192 14.40 313 865 7.73 / 100.01 5 129
10 14 -0.12 8 14.30 311 36 7.77 / 100.04 6 136
Average= 10.00
(KJ/cycle)

Cycle 13 GMT 18/ 8/2017 5:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.52 64 14.50 445 413 0.41 / 85.06 5 24
2 7 2025.08 100 12.61 3194 4028 4.44 / 89.09 24 45
3 13 1949.96 20 13.34 3125 834 5.27 / 89.92 5 64
4 13 1651.56 20 13.59 2694 732 6.01 / 90.65 5 74
5 13 914.48 20 13.99 1635 457 6.46 / 91.11 5 92
6 13 378.40 20 14.34 880 252 6.72 / 91.36 5 97
7 8 -0.20 214 14.44 294 909 7.62 / 92.27 5 138
Average= 10.25
(KJ/cycle)

Cycle 12 GMT 8/ 8/2017 8:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.08 64 14.52 442 411 0.41 / 77.46 5 23
2 7 2008.36 100 12.66 3143 3979 4.39 / 81.44 23 46
3 13 1929.72 20 13.38 3031 811 5.20 / 82.25 5 63
4 13 1608.52 20 13.60 2651 721 5.92 / 82.97 5 76
5 13 1069.76 20 13.90 1855 516 6.44 / 83.49 5 91
6 13 309.00 20 14.41 777 224 6.66 / 83.71 5 96
7 13 21.96 20 14.74 334 98 6.76 / 83.81 5 91
8 8 -0.16 194 14.44 290 812 7.57 / 84.62 5 142
9 14 -0.20 6 14.34 287 25 7.60 / 84.65 13 135
Average= 10.58
(KJ/cycle)

Cycle 11 GMT 29/ 7/2017 11:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.76 64 14.53 437 406 0.41 / 69.78 5 22
2 7 2032.56 100 12.66 3183 4030 4.44 / 73.81 5 44
3 13 1958.16 20 13.34 3121 833 5.27 / 74.64 5 64
4 13 1644.96 20 13.59 2685 730 6.00 / 75.37 5 75
5 13 910.12 20 14.00 1619 453 6.45 / 75.82 5 92
6 13 488.20 20 14.27 1033 295 6.75 / 76.12 5 97
7 13 1.68 20 14.78 298 88 6.83 / 76.21 5 98
8 8 -0.20 194 14.44 292 818 7.65 / 77.03 5 130
9 14 -0.24 6 14.34 290 25 7.68 / 77.05 8 132
Average= 11.01
(KJ/cycle)

Cycle 10 GMT 19/ 7/2017 13:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.00 65 14.53 437 413 0.41 / 62.15 5 20
2 3 956.64 -1 14.53 437 0 0.00 / 62.15 5 20
3 7 2006.84 100 12.73 3123 3976 4.39 / 66.12 20 45
4 13 1935.56 20 13.37 3086 825 5.21 / 66.95 5 64
5 13 1631.56 20 13.59 2678 728 5.94 / 67.68 5 75
6 13 993.56 20 13.95 1729 482 6.42 / 68.16 5 93
7 13 455.32 20 14.30 988 283 6.71 / 68.44 5 97
8 8 -0.08 221 14.45 292 932 7.64 / 69.37 5 133
Average= 11.56
(KJ/cycle)

Cycle 9 GMT 9/ 7/2017 16:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.24 65 14.55 435 411 0.41 / 54.46 5 17
2 3 1029.56 1 14.56 1913 28 0.44 / 54.49 5 12
3 7 2033.20 101 12.72 3132 4024 4.46 / 58.51 12 45
4 13 1952.84 20 13.35 3098 827 5.29 / 59.34 5 63
5 13 1643.72 20 13.59 2647 719 6.01 / 60.06 5 74
6 13 990.24 20 13.95 1729 482 6.49 / 60.54 5 94
7 13 358.16 20 14.39 841 242 6.73 / 60.78 5 96
8 13 68.16 20 14.70 409 120 6.85 / 60.90 5 100
9 8 -0.32 194 14.47 288 808 7.66 / 61.71 5 133
10 14 -0.32 6 14.34 288 25 7.69 / 61.73 9 128
Average= 12.35
(KJ/cycle)

Cycle 8 GMT 29/ 6/2017 19: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.44 66 14.54 426 409 0.41 / 46.64 5 17
2 3 937.48 -1 14.54 426 0 0.00 / 46.64 5 17
3 7 2032.00 100 12.73 3183 4052 4.46 / 50.69 17 47
4 13 1964.32 20 13.33 3122 832 5.29 / 51.52 5 63
5 13 1866.60 20 13.45 2987 804 6.10 / 52.33 5 69
6 13 998.92 20 13.95 1745 487 6.58 / 52.81 5 92
7 13 473.44 20 14.31 1003 287 6.87 / 53.10 5 97
8 13 68.92 20 14.69 408 120 6.99 / 53.22 5 100
9 8 -0.28 199 14.46 286 823 7.81 / 54.04 5 134
10 14 -0.08 1 14.34 288 4 7.82 / 54.05 11 112
Average= 13.51
(KJ/cycle)

Cycle 7 GMT 19/ 6/2017 21:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.40 66 14.56 421 405 0.40 / 38.78 5 15
2 7 2011.56 100 12.75 3146 4011 4.42 / 42.80 15 48
3 13 1943.84 20 13.35 3049 814 5.23 / 43.61 5 62
4 13 1744.72 20 13.57 2779 754 5.98 / 44.36 5 71
5 13 1304.64 20 13.78 2183 602 6.59 / 44.97 5 88
6 13 529.24 20 14.26 1077 307 6.89 / 45.27 5 95
7 13 93.40 20 14.66 454 133 7.03 / 45.41 5 101
8 8 -0.28 194 14.45 285 799 7.82 / 46.20 5 130
9 14 -0.44 6 14.33 286 25 7.85 / 46.23 9 124
Average= 15.41
(KJ/cycle)

Cycle 6 GMT 10/ 6/2017 0:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.64 73 14.53 425 451 0.45 / 30.60 5 14
2 3 769.84 -4 14.53 425 0 0.00 / 30.60 5 14
3 7 2034.24 40 13.14 3231 1698 2.15 / 32.30 14 48
4 13 2118.52 20 13.28 3382 898 3.05 / 33.20 5 53
5 13 2157.36 20 13.27 3416 907 3.95 / 34.11 5 55
6 13 2103.80 20 13.32 3339 890 4.84 / 34.99 5 59
7 13 2020.52 20 13.34 3246 866 5.71 / 35.86 5 65
8 13 1714.56 20 13.52 2802 758 6.47 / 36.62 5 75
9 13 1061.16 20 13.87 1837 510 6.98 / 37.13 5 93
10 13 512.44 20 14.26 1041 297 7.27 / 37.42 5 93
11 13 80.40 20 14.67 430 126 7.40 / 37.55 5 102
12 8 -0.36 194 14.44 287 804 8.20 / 38.35 5 132
13 14 -0.16 6 14.31 287 25 8.23 / 38.38 7 123
Average= 19.19
(KJ/cycle)

Cycle 5 GMT 31/ 5/2017 2: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.68 31 14.82 426 196 0.20 / 21.54 5 13
2 10 1064.16 9 14.44 1884 245 0.44 / 21.79 5 45
3 10 1155.48 8 14.21 2028 231 0.67 / 22.02 5 48
4 10 1243.44 8 14.11 2141 242 0.91 / 22.26 5 50
5 10 1296.56 5 14.19 2223 158 1.07 / 22.42 5 56
6 10 1350.44 3 14.36 2259 97 1.17 / 22.52 5 60
7 3 1368.92 9 14.17 2283 291 1.46 / 22.81 5 80
8 7 2009.08 40 13.11 3174 1664 3.12 / 24.47 80 49
9 13 2095.08 20 13.26 3304 876 4.00 / 25.35 5 54
10 13 2133.96 20 13.23 3418 904 4.90 / 26.25 5 57
11 13 2081.12 20 13.28 3313 880 5.78 / 27.13 5 60
12 13 1996.40 20 13.33 3175 846 6.63 / 27.98 5 66
13 13 1465.80 20 13.63 2416 659 7.29 / 28.64 5 81
14 13 838.80 20 14.00 1519 425 7.71 / 29.06 5 94
15 13 305.08 20 14.42 758 219 7.93 / 29.28 5 97
16 8 -0.52 213 14.42 283 869 8.80 / 30.15 5 137
Average= 30.15
(KJ/cycle)

Cycle 3 GMT 20/ 5/2017 4:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.12 74 14.50 418 449 0.45 / 15.31 5 13
2 3 722.96 -4 14.50 418 0 0.00 / 15.31 5 13
3 7 1509.08 41 13.47 2414 1333 1.78 / 16.65 13 52
4 13 1610.76 20 13.50 2583 697 2.48 / 17.35 5 58
5 13 1667.80 20 13.45 2694 725 3.20 / 18.07 5 60
6 13 1626.68 20 13.46 2625 707 3.91 / 18.78 5 64
7 13 1549.88 20 13.53 2492 674 4.58 / 19.45 5 70
8 13 1245.20 20 13.71 2109 578 5.16 / 20.03 5 83
9 13 601.60 20 14.16 1153 327 5.49 / 20.36 5 88
10 13 146.36 20 14.57 527 154 5.64 / 20.51 5 96
11 8 -0.32 208 14.42 280 840 6.48 / 21.35 5 136
Average= 5.34
(KJ/cycle)

Cycle 2 GMT 19/ 5/2017 4: 7: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.88 31 14.64 433 197 0.20 / 7.89 5 17
2 10 1101.28 11 14.14 1934 301 0.50 / 8.19 5 46
3 10 1196.40 9 13.96 2072 260 0.76 / 8.46 5 48
4 10 1268.60 7 13.97 2164 212 0.97 / 8.67 5 52
5 10 1319.40 5 14.05 2241 157 1.13 / 8.82 5 56
6 10 1356.00 3 14.09 2312 98 1.22 / 8.92 5 61
7 3 1387.80 9 13.96 2310 290 1.51 / 9.21 5 81
8 7 1509.20 40 13.35 2406 1285 2.80 / 10.50 81 54
9 13 1603.48 20 13.39 2591 694 3.49 / 11.19 5 60
10 13 1653.16 20 13.38 2667 714 4.21 / 11.90 5 61
11 13 1607.08 20 13.43 2567 689 4.90 / 12.59 5 65
12 13 1524.24 20 13.48 2444 659 5.56 / 13.25 5 69
13 13 918.92 20 13.87 1600 444 6.00 / 13.70 5 87
14 13 399.36 20 14.26 893 255 6.25 / 13.95 5 95
15 13 45.56 20 14.67 363 107 6.36 / 14.06 5 97
16 8 0.08 202 14.39 278 808 7.17 / 14.87 5 147
Average= 4.96
(KJ/cycle)

Cycle 1 GMT 18/ 5/2017 4:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.52 31 14.62 416 189 0.19 / 1.97 5 7
2 10 1087.08 10 13.85 1914 265 0.45 / 2.24 5 35
3 10 1184.04 9 13.66 2041 251 0.70 / 2.49 5 38
4 3 1185.72 5 13.53 2052 139 0.84 / 2.63 5 38
5 7 1621.48 40 13.00 2558 1330 2.17 / 3.96 38 46
6 13 1525.44 20 13.27 2452 651 2.82 / 4.61 5 55
7 13 1093.92 20 13.57 1870 508 3.33 / 5.12 5 75
8 13 311.80 20 14.21 769 219 3.55 / 5.34 5 89
9 8 308.44 246 13.64 704 2362 5.91 / 7.70 5 131
Average= 3.85
(KJ/cycle)

Cycle 0 GMT 17/ 5/2017 20:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 140.88 30 14.30 461 198 0.20 / 0.20 5 8
2 7 156.44 40 14.23 475 270 0.47 / 0.47 8 11
3 13 231.20 20 14.40 597 172 0.64 / 0.64 5 16
4 13 231.64 20 14.40 609 175 0.82 / 0.82 5 26
5 13 153.72 20 14.50 499 145 0.96 / 0.96 5 34
6 8 -0.32 232 14.45 246 825 1.78 / 1.78 5 147
Average= 1.78
(KJ/cycle)