Cycle 261 GMT 5/11/2024 10:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.92 22 14.93 464 152 0.15 / 1172.71 3 3
2 7 2002.48 44 14.01 2979 1836 1.99 / 1174.54 3 3
3 13 1872.04 22 14.05 2812 869 2.86 / 1175.41 2 3
4 13 1009.20 22 14.38 1666 527 3.39 / 1175.94 2 3
5 13 440.52 22 14.66 955 308 3.69 / 1176.25 2 3
6 8 0.16 165 14.94 306 754 4.45 / 1177.00 3 3
Average= 4.75
(KJ/cycle)

Cycle 260 GMT 26/10/2024 12:14: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.20 22 14.94 469 154 0.15 / 1168.28 3 3
2 7 2002.16 44 14.01 2984 1839 1.99 / 1170.12 3 3
3 13 1755.60 22 14.10 2645 820 2.81 / 1170.94 2 3
4 13 882.36 22 14.44 1500 477 3.29 / 1171.42 2 3
5 13 340.32 22 14.73 814 264 3.55 / 1171.68 2 3
6 13 41.68 22 14.94 366 120 3.67 / 1171.80 3 3
7 8 -0.12 165 14.92 307 756 4.43 / 1172.56 3 3
Average= 4.75
(KJ/cycle)

Cycle 259 GMT 16/10/2024 13:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.44 22 14.94 460 151 0.15 / 1164.04 3 3
2 7 2001.92 44 14.02 2962 1827 1.98 / 1165.87 3 3
3 13 1592.00 22 14.16 2433 758 2.74 / 1166.62 2 3
4 13 892.24 22 14.44 1513 481 3.22 / 1167.11 2 3
5 13 342.20 22 14.73 819 265 3.48 / 1167.37 2 3
6 8 0.04 165 14.94 306 754 4.24 / 1168.12 3 3
Average= 4.75
(KJ/cycle)

Cycle 258 GMT 6/10/2024 15:26: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.68 21 14.94 465 146 0.15 / 1159.66 3 3
2 7 2004.44 44 14.03 2988 1845 1.99 / 1161.50 3 3
3 13 1612.08 22 14.14 2465 767 2.76 / 1162.27 2 3
4 13 1050.08 22 14.37 1713 542 3.30 / 1162.81 2 3
5 13 459.72 22 14.64 980 316 3.61 / 1163.13 2 3
6 8 0.04 165 14.94 308 759 4.37 / 1163.89 3 3
Average= 4.75
(KJ/cycle)

Cycle 257 GMT 26/ 9/2024 17: 2: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.44 21 14.93 461 145 0.14 / 1155.42 3 3
2 7 2007.16 44 14.02 2979 1838 1.98 / 1157.26 3 3
3 13 1475.64 22 14.18 2300 718 2.70 / 1157.98 2 3
4 13 927.64 22 14.42 1560 495 3.19 / 1158.47 2 3
5 13 371.96 22 14.71 869 281 3.48 / 1158.75 2 3
6 8 0.04 165 14.94 309 762 4.24 / 1159.51 3 3
Average= 4.75
(KJ/cycle)

Cycle 256 GMT 16/ 9/2024 18:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.80 22 14.93 467 153 0.15 / 1151.16 3 3
2 7 2005.16 44 14.01 2984 1839 1.99 / 1153.00 3 3
3 13 1607.68 22 14.14 2454 763 2.76 / 1153.76 2 3
4 13 898.24 22 14.44 1522 484 3.24 / 1154.25 2 3
5 13 342.84 22 14.73 833 270 3.51 / 1154.52 3 3
6 8 0.08 165 14.94 309 762 4.27 / 1155.28 3 3
Average= 4.75
(KJ/cycle)

Cycle 255 GMT 6/ 9/2024 19:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.60 21 14.94 465 146 0.15 / 1146.75 3 3
2 7 2009.44 44 14.02 2990 1844 1.99 / 1148.59 3 3
3 13 1595.48 22 14.15 2427 756 2.75 / 1149.35 2 3
4 13 1016.44 22 14.37 1678 530 3.28 / 1149.88 2 3
5 13 313.68 22 14.76 778 253 3.53 / 1150.13 2 3
6 13 37.80 22 14.95 360 118 3.65 / 1150.25 3 3
7 8 0.08 165 14.93 307 756 4.40 / 1151.01 3 3
Average= 4.76
(KJ/cycle)

Cycle 254 GMT 27/ 8/2024 21:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.76 22 14.95 470 155 0.15 / 1142.36 3 3
2 7 2003.60 45 14.02 2973 1876 2.03 / 1144.24 3 3
3 13 1732.16 22 14.11 2607 809 2.84 / 1145.05 2 3
4 13 972.12 22 14.40 1608 509 3.35 / 1145.56 2 3
5 13 405.32 22 14.69 902 292 3.64 / 1145.85 2 3
6 8 0.16 165 14.94 305 752 4.39 / 1146.60 3 3
Average= 4.76
(KJ/cycle)

Cycle 253 GMT 17/ 8/2024 23:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.48 21 14.95 469 147 0.15 / 1138.14 3 3
2 7 2002.32 44 14.02 2961 1827 1.97 / 1139.96 3 3
3 13 1586.48 22 14.16 2427 756 2.73 / 1140.72 2 3
4 13 877.72 22 14.45 1501 477 3.21 / 1141.20 2 3
5 13 333.00 22 14.74 808 262 3.47 / 1141.46 2 3
6 8 0.08 165 14.94 305 752 4.22 / 1142.21 3 3
Average= 4.76
(KJ/cycle)

Cycle 252 GMT 8/ 8/2024 1: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.56 22 14.94 461 152 0.15 / 1133.85 3 3
2 7 2002.20 44 14.02 2974 1835 1.99 / 1135.69 3 3
3 13 1605.16 22 14.14 2456 764 2.75 / 1136.45 2 3
4 13 1025.96 22 14.37 1683 532 3.28 / 1136.98 2 3
5 13 326.16 22 14.75 799 259 3.54 / 1137.24 2 3
6 8 0.16 165 14.95 303 747 4.29 / 1137.99 3 3
Average= 4.76
(KJ/cycle)

Cycle 251 GMT 29/ 7/2024 2:35:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.00 22 14.94 461 152 0.15 / 1129.46 3 3
2 7 2005.52 44 14.02 2986 1842 1.99 / 1131.30 3 3
3 13 1597.48 22 14.15 2443 761 2.75 / 1132.06 2 3
4 13 1163.52 22 14.30 1865 587 3.34 / 1132.65 2 3
5 13 424.08 22 14.68 928 300 3.64 / 1132.95 2 3
6 8 0.12 165 14.94 305 752 4.39 / 1133.70 3 3
Average= 4.76
(KJ/cycle)

Cycle 250 GMT 19/ 7/2024 4:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.96 22 14.94 448 147 0.15 / 1125.21 3 3
2 7 2002.80 44 14.03 2959 1827 1.97 / 1127.04 3 3
3 13 1479.40 22 14.20 2285 714 2.69 / 1127.75 2 3
4 13 1048.16 22 14.36 1718 543 3.23 / 1128.29 2 3
5 13 331.72 22 14.74 806 261 3.49 / 1128.56 2 3
6 8 0.08 165 14.95 305 752 4.24 / 1129.31 3 3
Average= 4.77
(KJ/cycle)

Cycle 249 GMT 9/ 7/2024 5:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.40 21 14.94 465 146 0.15 / 1120.79 3 3
2 7 2007.80 44 14.01 2987 1841 1.99 / 1122.63 3 3
3 13 1605.12 22 14.15 2444 761 2.75 / 1123.39 2 3
4 13 1046.88 22 14.37 1707 540 3.29 / 1123.93 2 3
5 13 337.16 22 14.74 817 265 3.55 / 1124.19 2 3
6 13 44.28 22 14.94 369 121 3.67 / 1124.32 3 3
7 8 0.00 165 14.94 303 747 4.42 / 1125.06 3 3
Average= 4.77
(KJ/cycle)

Cycle 248 GMT 29/ 6/2024 7:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.64 21 14.94 454 142 0.14 / 1116.37 3 3
2 7 2003.44 45 14.03 2966 1873 2.02 / 1118.24 3 3
3 13 1735.76 22 14.10 2621 813 2.83 / 1119.06 2 3
4 13 1014.36 22 14.38 1677 531 3.36 / 1119.59 2 3
5 13 425.00 22 14.67 928 300 3.66 / 1119.89 2 3
6 8 0.16 165 14.94 306 754 4.41 / 1120.64 3 3
Average= 4.77
(KJ/cycle)

Cycle 247 GMT 19/ 6/2024 9:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.96 22 14.95 465 153 0.15 / 1111.83 3 3
2 7 2005.80 44 14.02 2971 1833 1.99 / 1113.67 3 3
3 13 1874.20 22 14.07 2791 864 2.85 / 1114.53 2 3
4 13 985.40 22 14.39 1646 521 3.37 / 1115.05 2 3
5 13 410.28 22 14.69 909 294 3.66 / 1115.35 2 3
6 13 57.00 22 14.94 389 128 3.79 / 1115.47 3 3
7 8 -0.04 165 14.93 307 756 4.55 / 1116.23 3 3
Average= 4.77
(KJ/cycle)

Cycle 246 GMT 9/ 6/2024 11: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.60 21 14.93 474 149 0.15 / 1107.47 3 3
2 7 2002.72 44 14.03 2970 1833 1.98 / 1109.31 3 3
3 13 1600.00 22 14.15 2449 762 2.74 / 1110.07 2 3
4 13 900.64 22 14.45 1517 482 3.23 / 1110.55 2 3
5 13 348.28 22 14.73 827 268 3.49 / 1110.82 2 3
6 13 22.40 22 14.96 336 111 3.61 / 1110.93 3 3
7 8 0.04 165 14.94 305 752 4.36 / 1111.68 3 3
Average= 4.77
(KJ/cycle)

Cycle 245 GMT 30/ 5/2024 12:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.44 21 14.94 466 146 0.15 / 1102.90 3 3
2 3 1017.28 1 14.98 1848 28 0.17 / 1102.93 2 3
3 7 2001.28 44 14.02 2982 1840 2.01 / 1104.77 3 3
4 13 1723.12 22 14.12 2610 811 2.82 / 1105.58 2 3
5 13 980.24 22 14.40 1631 517 3.34 / 1106.10 2 3
6 13 545.20 22 14.61 1085 349 3.69 / 1106.45 2 3
7 13 49.68 22 14.94 381 125 3.81 / 1106.57 3 3
8 8 0.08 165 14.93 306 754 4.57 / 1107.32 3 3
Average= 4.77
(KJ/cycle)

Cycle 244 GMT 20/ 5/2024 14:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.12 21 14.93 456 143 0.14 / 1098.34 3 3
2 7 2007.28 44 14.03 2969 1833 1.98 / 1100.17 3 3
3 13 1738.64 22 14.11 2648 822 2.80 / 1101.00 2 3
4 13 1134.72 22 14.32 1832 577 3.37 / 1101.57 2 3
5 13 405.76 22 14.69 912 295 3.67 / 1101.87 2 3
6 13 58.84 22 14.93 394 129 3.80 / 1102.00 3 3
7 8 0.00 165 14.93 308 759 4.56 / 1102.76 3 4
Average= 4.77
(KJ/cycle)

Cycle 243 GMT 10/ 5/2024 16:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.48 21 14.94 456 143 0.14 / 1093.85 3 3
2 7 2001.84 44 14.02 2988 1843 1.99 / 1095.70 3 3
3 13 1733.44 22 14.10 2622 813 2.80 / 1096.51 2 3
4 13 990.28 22 14.40 1647 522 3.32 / 1097.03 2 3
5 13 407.52 22 14.69 906 293 3.61 / 1097.33 2 3
6 13 30.76 22 14.95 353 116 3.73 / 1097.44 3 3
7 8 0.12 165 14.93 307 756 4.49 / 1098.20 3 4
Average= 4.77
(KJ/cycle)

Cycle 242 GMT 30/ 4/2024 18:34: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.64 22 14.95 462 152 0.15 / 1089.47 3 3
2 7 2007.60 44 14.02 2978 1837 1.99 / 1091.31 3 3
3 13 1608.40 22 14.15 2445 761 2.75 / 1092.07 2 3
4 13 909.00 22 14.43 1541 489 3.24 / 1092.56 2 3
5 13 351.64 22 14.72 838 271 3.51 / 1092.83 2 3
6 13 44.08 22 14.94 373 123 3.63 / 1092.95 3 3
7 8 0.04 165 14.93 307 756 4.39 / 1093.71 3 4
Average= 4.78
(KJ/cycle)

Cycle 241 GMT 20/ 4/2024 20: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.00 22 14.95 454 149 0.15 / 1085.09 3 3
2 7 2012.32 44 14.02 2987 1843 1.99 / 1086.93 3 3
3 13 1490.48 22 14.19 2295 716 2.71 / 1087.65 2 3
4 13 1062.20 22 14.35 1733 547 3.26 / 1088.19 2 3
5 13 338.64 22 14.74 819 266 3.52 / 1088.46 3 3
6 13 21.20 22 14.96 335 110 3.63 / 1088.57 3 3
7 8 0.16 165 14.94 305 752 4.38 / 1089.32 3 3
Average= 4.78
(KJ/cycle)

Cycle 240 GMT 10/ 4/2024 21:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.52 22 14.96 457 150 0.15 / 1080.49 3 3
2 7 2007.92 44 14.01 2988 1842 1.99 / 1082.33 3 3
3 13 1877.52 22 14.06 2822 873 2.87 / 1083.20 2 3
4 13 997.28 22 14.40 1658 525 3.39 / 1083.73 2 3
5 13 557.28 22 14.60 1113 357 3.75 / 1084.08 2 3
6 13 35.20 22 14.96 352 116 3.86 / 1084.20 3 3
7 8 0.12 165 14.94 300 740 4.60 / 1084.94 3 4
Average= 4.78
(KJ/cycle)

Cycle 239 GMT 31/ 3/2024 22:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.20 21 14.96 455 143 0.14 / 1075.99 3 3
2 3 1024.96 1 14.96 1819 27 0.17 / 1076.01 2 3
3 7 2007.64 44 14.02 2973 1834 2.00 / 1077.85 3 3
4 13 1607.00 22 14.15 2452 763 2.77 / 1078.61 2 3
5 13 1030.52 22 14.37 1708 540 3.31 / 1079.15 2 3
6 13 465.12 22 14.65 995 321 3.63 / 1079.47 2 3
7 13 40.96 22 14.95 364 120 3.75 / 1079.59 3 3
8 8 0.08 165 14.95 301 742 4.49 / 1080.33 3 3
Average= 4.78
(KJ/cycle)

Cycle 238 GMT 22/ 3/2024 0:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.68 22 14.94 446 147 0.15 / 1071.45 3 3
2 3 965.96 -1 15.32 0 0 0.00 / 1071.45 3 3
3 3 1019.92 1 14.98 1799 27 0.17 / 1071.48 2 3
4 7 2007.04 44 14.02 2980 1838 2.01 / 1073.32 3 3
5 13 1744.04 22 14.11 2632 817 2.83 / 1074.14 2 3
6 13 1164.24 22 14.31 1867 588 3.42 / 1074.72 2 3
7 13 309.60 22 14.76 787 256 3.67 / 1074.98 2 3
8 13 46.00 22 14.95 367 121 3.79 / 1075.10 3 3
9 8 0.12 165 14.95 302 745 4.54 / 1075.84 3 3
Average= 4.78
(KJ/cycle)

Cycle 237 GMT 12/ 3/2024 2: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.16 21 14.95 455 143 0.14 / 1067.00 3 3
2 7 2002.72 44 14.01 2998 1848 1.99 / 1068.85 3 3
3 13 1588.00 22 14.16 2423 755 2.75 / 1069.61 2 3
4 13 1030.52 22 14.37 1695 536 3.28 / 1070.14 2 3
5 13 445.08 22 14.67 953 308 3.59 / 1070.45 2 3
6 13 39.40 22 14.95 357 117 3.71 / 1070.57 3 3
7 8 0.00 165 14.94 300 740 4.45 / 1071.31 3 3
Average= 4.78
(KJ/cycle)

Cycle 236 GMT 2/ 3/2024 3:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.76 21 14.95 456 143 0.14 / 1062.65 3 3
2 7 2005.28 44 14.02 2970 1832 1.98 / 1064.48 3 3
3 13 1609.48 22 14.15 2461 766 2.74 / 1065.24 2 3
4 13 902.04 22 14.44 1521 483 3.22 / 1065.73 2 3
5 13 357.12 22 14.72 844 273 3.50 / 1066.00 2 3
6 13 48.20 22 14.95 373 123 3.62 / 1066.12 3 3
7 8 0.04 165 14.94 299 737 4.36 / 1066.86 3 3
Average= 4.78
(KJ/cycle)

Cycle 235 GMT 21/ 2/2024 4:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.80 21 14.94 453 142 0.14 / 1058.28 3 3
2 7 2003.92 44 14.02 2974 1835 1.98 / 1060.11 3 3
3 13 1612.28 22 14.14 2473 769 2.75 / 1060.88 2 3
4 13 916.36 22 14.43 1546 491 3.24 / 1061.37 2 3
5 13 340.68 22 14.74 811 263 3.50 / 1061.64 3 3
6 13 41.64 22 14.94 365 120 3.62 / 1061.76 3 3
7 8 0.08 165 14.94 303 747 4.37 / 1062.50 3 3
Average= 4.79
(KJ/cycle)

Cycle 234 GMT 11/ 2/2024 6:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.48 22 14.94 463 152 0.15 / 1053.76 3 3
2 7 2006.76 44 14.01 2976 1835 1.99 / 1055.59 3 3
3 13 1739.08 22 14.11 2611 811 2.80 / 1056.40 2 3
4 13 1033.16 22 14.37 1694 536 3.33 / 1056.94 2 3
5 13 453.56 22 14.66 972 313 3.65 / 1057.25 2 3
6 13 74.12 22 14.92 419 138 3.78 / 1057.39 3 3
7 8 0.08 165 14.93 303 746 4.53 / 1058.14 3 5
Average= 4.79
(KJ/cycle)

Cycle 233 GMT 1/ 2/2024 7:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.72 21 14.94 453 142 0.14 / 1049.37 3 3
2 7 2006.60 44 14.02 2978 1837 1.98 / 1051.21 3 3
3 13 1493.68 22 14.19 2302 719 2.70 / 1051.92 2 3
4 13 1063.56 22 14.34 1745 551 3.25 / 1052.48 2 3
5 13 349.40 22 14.72 839 272 3.52 / 1052.75 2 3
6 13 25.88 22 14.95 342 112 3.63 / 1052.86 3 3
7 8 -0.04 165 14.93 303 746 4.38 / 1053.61 3 3
Average= 4.79
(KJ/cycle)

Cycle 232 GMT 22/ 1/2024 9:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.72 22 14.94 447 147 0.15 / 1045.07 3 3
2 7 2004.96 44 14.02 2969 1832 1.98 / 1046.90 3 3
3 13 1487.28 22 14.19 2292 716 2.69 / 1047.61 2 3
4 13 820.84 22 14.48 1416 451 3.15 / 1048.06 2 3
5 13 411.60 22 14.68 908 293 3.44 / 1048.36 2 3
6 13 57.84 22 14.93 391 128 3.57 / 1048.49 3 3
7 8 0.04 165 14.93 301 741 4.31 / 1049.23 3 3
Average= 4.79
(KJ/cycle)

Cycle 231 GMT 12/ 1/2024 10:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.08 21 14.94 462 145 0.14 / 1040.57 3 3
2 7 2002.80 44 14.02 2967 1830 1.98 / 1042.40 3 3
3 13 1600.80 22 14.16 2451 764 2.74 / 1043.16 2 3
4 13 1173.88 22 14.31 1880 592 3.33 / 1043.75 2 3
5 13 419.08 22 14.67 929 300 3.63 / 1044.05 2 3
6 13 30.32 22 14.95 347 114 3.74 / 1044.17 3 3
7 8 0.16 165 14.93 305 751 4.50 / 1044.92 3 3
Average= 4.79
(KJ/cycle)

Cycle 230 GMT 2/ 1/2024 12:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.24 21 14.94 458 144 0.14 / 1036.05 3 3
2 7 2005.36 45 14.01 2992 1886 2.03 / 1037.94 3 3
3 13 1609.68 22 14.15 2468 768 2.80 / 1038.70 2 3
4 13 1042.16 22 14.37 1693 535 3.33 / 1039.24 2 3
5 13 454.00 22 14.65 970 313 3.65 / 1039.55 2 3
6 13 34.88 22 14.94 359 118 3.76 / 1039.67 3 3
7 8 0.08 165 14.92 306 753 4.52 / 1040.42 3 3
Average= 4.79
(KJ/cycle)

Cycle 229 GMT 23/12/2023 14:13: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.76 22 14.93 468 154 0.15 / 1031.56 3 3
2 7 2002.52 44 14.02 2973 1834 1.99 / 1033.39 3 3
3 13 1733.04 22 14.11 2618 813 2.80 / 1034.20 2 3
4 13 1015.40 22 14.38 1678 531 3.33 / 1034.73 2 3
5 13 439.48 22 14.66 945 305 3.64 / 1035.04 2 3
6 13 34.16 22 14.94 355 117 3.75 / 1035.15 3 3
7 8 -0.08 165 14.92 305 751 4.50 / 1035.91 3 4
Average= 4.80
(KJ/cycle)

Cycle 228 GMT 13/12/2023 15:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.68 22 14.94 452 149 0.15 / 1027.24 3 3
2 7 2003.92 44 14.02 2964 1828 1.98 / 1029.07 3 3
3 13 1469.44 22 14.19 2280 712 2.69 / 1029.78 2 3
4 13 929.40 22 14.42 1560 495 3.18 / 1030.27 2 3
5 13 352.68 22 14.71 834 270 3.45 / 1030.54 2 3
6 13 23.00 22 14.95 337 111 3.56 / 1030.66 3 3
7 8 -0.04 165 14.93 303 746 4.31 / 1031.40 3 3
Average= 4.80
(KJ/cycle)

Cycle 227 GMT 3/12/2023 17: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.64 21 14.94 463 145 0.15 / 1022.68 3 3
2 7 2012.28 44 14.01 2972 1832 1.98 / 1024.52 3 3
3 13 1881.40 22 14.05 2814 870 2.85 / 1025.39 2 3
4 13 1105.12 22 14.35 1771 559 3.41 / 1025.95 2 3
5 13 386.48 22 14.70 883 286 3.69 / 1026.23 2 3
6 13 30.60 22 14.95 346 114 3.81 / 1026.34 3 3
7 8 0.16 165 14.93 303 746 4.55 / 1027.09 3 3
Average= 4.80
(KJ/cycle)

Cycle 226 GMT 23/11/2023 18:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.32 21 14.93 454 142 0.14 / 1018.45 3 3
2 7 2002.48 44 14.02 2974 1835 1.98 / 1020.29 3 3
3 13 1596.96 22 14.15 2455 764 2.74 / 1021.05 2 3
4 13 898.96 22 14.44 1509 479 3.22 / 1021.53 2 3
5 13 341.08 22 14.73 820 266 3.49 / 1021.79 2 3
6 8 0.08 165 14.94 302 744 4.23 / 1022.54 3 3
Average= 4.80
(KJ/cycle)

Cycle 225 GMT 13/11/2023 20:21: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.88 21 14.93 451 141 0.14 / 1014.04 3 3
2 7 2004.60 44 14.02 2979 1838 1.98 / 1015.88 3 3
3 13 1598.04 22 14.15 2443 761 2.74 / 1016.64 2 3
4 13 896.68 22 14.43 1506 478 3.22 / 1017.12 2 3
5 13 480.40 22 14.63 995 320 3.54 / 1017.44 2 3
6 13 41.04 22 14.93 363 119 3.66 / 1017.56 3 3
7 8 0.00 165 14.92 304 748 4.41 / 1018.31 3 3
Average= 4.80
(KJ/cycle)

Cycle 224 GMT 3/11/2023 21:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.92 22 14.93 462 152 0.15 / 1009.40 3 3
2 7 2008.28 45 14.03 2971 1876 2.03 / 1011.28 3 3
3 13 1884.56 22 14.05 2816 870 2.90 / 1012.15 2 3
4 13 995.52 22 14.39 1636 518 3.42 / 1012.67 2 3
5 13 553.24 22 14.59 1107 355 3.77 / 1013.02 2 3
6 13 28.24 22 14.94 351 115 3.89 / 1013.14 3 3
7 8 0.00 165 14.92 310 763 4.65 / 1013.90 3 3
Average= 4.81
(KJ/cycle)

Cycle 223 GMT 24/10/2023 23:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.76 21 14.94 460 144 0.14 / 1005.00 3 3
2 3 1016.16 1 14.98 1790 27 0.17 / 1005.03 2 3
3 7 2003.92 44 14.03 2968 1832 2.00 / 1006.86 3 3
4 13 1740.96 22 14.11 2616 812 2.82 / 1007.68 2 3
5 13 993.60 22 14.39 1637 518 3.33 / 1008.19 2 3
6 13 421.68 22 14.67 916 296 3.63 / 1008.49 3 3
7 8 0.16 165 14.93 310 764 4.39 / 1009.25 3 4
Average= 4.81
(KJ/cycle)

Cycle 222 GMT 15/10/2023 1:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.84 21 14.93 452 142 0.14 / 1000.81 3 3
2 7 2008.92 44 14.02 2986 1842 1.98 / 1002.65 3 3
3 13 1478.24 22 14.20 2264 707 2.69 / 1003.36 2 3
4 13 916.36 22 14.43 1535 487 3.18 / 1003.84 2 3
5 13 356.44 22 14.71 838 271 3.45 / 1004.11 2 3
6 8 0.04 165 14.93 303 746 4.20 / 1004.86 3 3
Average= 4.81
(KJ/cycle)

Cycle 221 GMT 5/10/2023 2:42: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.48 21 14.94 443 139 0.14 / 996.36 3 3
2 7 2003.76 44 14.03 2956 1825 1.96 / 998.18 3 3
3 13 1735.44 22 14.11 2603 808 2.77 / 998.99 2 3
4 13 1000.24 22 14.39 1636 518 3.29 / 999.51 2 3
5 13 424.04 22 14.66 928 299 3.59 / 999.81 2 3
6 13 14.48 22 14.95 318 105 3.69 / 999.91 3 3
7 8 0.04 165 14.92 306 753 4.45 / 1000.66 3 3
Average= 4.81
(KJ/cycle)

Cycle 220 GMT 25/ 9/2023 4:15:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.88 21 14.92 482 151 0.15 / 991.95 3 3
2 7 2002.36 44 14.03 2977 1838 1.99 / 993.79 3 3
3 13 1603.60 22 14.15 2441 760 2.75 / 994.55 2 3
4 13 1024.28 22 14.37 1695 536 3.28 / 995.08 2 3
5 13 314.56 22 14.74 782 254 3.54 / 995.34 2 3
6 13 42.24 22 14.93 370 122 3.66 / 995.46 3 3
7 8 0.08 165 14.92 309 761 4.42 / 996.22 3 3
Average= 4.81
(KJ/cycle)

Cycle 219 GMT 15/ 9/2023 5:55: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.56 21 14.92 467 146 0.15 / 987.42 3 3
2 7 2004.08 44 14.02 2968 1831 1.98 / 989.25 3 3
3 13 1612.64 22 14.15 2452 763 2.74 / 990.01 2 3
4 13 1042.44 22 14.36 1717 542 3.28 / 990.56 2 3
5 13 590.16 22 14.57 1143 366 3.65 / 990.92 2 3
6 13 23.44 22 14.94 343 113 3.76 / 991.04 3 3
7 8 0.04 165 14.92 309 761 4.52 / 991.80 3 3
Average= 4.81
(KJ/cycle)

Cycle 218 GMT 5/ 9/2023 7:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.36 22 14.92 494 162 0.16 / 983.09 3 3
2 7 2006.88 44 14.02 2993 1846 2.01 / 984.93 3 3
3 13 1588.68 22 14.15 2423 754 2.76 / 985.69 2 3
4 13 989.40 22 14.39 1648 522 3.28 / 986.21 2 3
5 13 420.80 22 14.66 926 299 3.58 / 986.51 2 3
6 8 -0.04 165 14.92 311 766 4.35 / 987.27 3 3
Average= 4.82
(KJ/cycle)

Cycle 217 GMT 26/ 8/2023 7:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.84 21 14.93 478 150 0.15 / 978.70 3 3
2 7 2005.80 44 14.02 2986 1842 1.99 / 980.54 3 3
3 13 1601.72 22 14.14 2463 766 2.76 / 981.31 2 3
4 13 1030.44 22 14.37 1699 537 3.30 / 981.84 2 3
5 13 455.12 22 14.64 975 314 3.61 / 982.16 2 3
6 8 0.16 165 14.92 312 768 4.38 / 982.93 3 3
Average= 4.82
(KJ/cycle)

Cycle 216 GMT 16/ 8/2023 7:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.08 22 14.94 473 155 0.16 / 974.24 3 3
2 7 2010.40 44 14.02 3011 1857 2.01 / 976.10 3 3
3 13 1883.44 22 14.06 2833 876 2.89 / 976.98 2 3
4 13 970.52 22 14.40 1608 509 3.40 / 977.48 2 3
5 13 405.72 22 14.68 920 297 3.70 / 977.78 2 3
6 8 0.12 165 14.93 311 766 4.46 / 978.55 3 3
Average= 4.82
(KJ/cycle)

Cycle 215 GMT 6/ 8/2023 7:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.68 21 14.94 471 148 0.15 / 969.90 3 3
2 3 1021.24 1 14.97 1829 27 0.18 / 969.92 2 3
3 7 2003.44 44 14.03 2957 1825 2.00 / 971.75 3 3
4 13 1605.88 22 14.16 2440 760 2.76 / 972.51 2 3
5 13 925.16 22 14.42 1556 494 3.25 / 973.00 2 3
6 13 490.56 22 14.62 1016 327 3.58 / 973.33 2 3
7 8 0.08 165 14.93 307 756 4.34 / 974.09 3 3
Average= 4.82
(KJ/cycle)

Cycle 214 GMT 27/ 7/2023 7:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.48 22 14.96 461 152 0.15 / 965.55 3 3
2 7 2003.24 44 14.03 2961 1828 1.98 / 967.38 3 3
3 13 1725.32 22 14.11 2610 810 2.79 / 968.19 2 3
4 13 989.68 22 14.38 1643 520 3.31 / 968.71 2 3
5 13 410.32 22 14.67 918 296 3.61 / 969.00 2 3
6 8 0.12 165 14.93 302 744 4.35 / 969.75 3 3
Average= 4.82
(KJ/cycle)

Cycle 213 GMT 17/ 7/2023 7:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.96 21 14.94 466 146 0.15 / 961.23 3 3
2 7 2002.28 44 14.03 2960 1827 1.97 / 963.06 3 3
3 13 1740.96 22 14.12 2620 814 2.79 / 963.87 2 3
4 13 1013.20 22 14.37 1671 528 3.32 / 964.40 2 3
5 13 322.68 22 14.74 792 257 3.57 / 964.66 2 3
6 8 0.00 165 14.94 301 742 4.31 / 965.40 3 3
Average= 4.83
(KJ/cycle)

Cycle 212 GMT 7/ 7/2023 7:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.08 22 14.95 464 153 0.15 / 956.72 3 3
2 7 2001.80 44 14.04 2961 1829 1.98 / 958.55 3 3
3 13 1731.00 22 14.11 2615 812 2.79 / 959.37 2 3
4 13 1130.88 22 14.31 1845 581 3.37 / 959.95 2 3
5 13 395.04 22 14.69 892 288 3.66 / 960.23 2 3
6 13 26.80 22 14.95 337 111 3.77 / 960.35 3 3
7 8 0.16 165 14.93 300 739 4.51 / 961.08 3 3
Average= 4.83
(KJ/cycle)

Cycle 211 GMT 27/ 6/2023 6:56: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.36 21 14.93 460 144 0.14 / 952.44 3 3
2 7 2003.04 44 14.04 2966 1832 1.98 / 954.28 3 3
3 13 1600.60 22 14.16 2434 758 2.73 / 955.03 2 3
4 13 893.24 22 14.44 1513 481 3.22 / 955.51 2 3
5 13 472.64 22 14.64 987 318 3.53 / 955.83 2 3
6 8 0.16 165 14.94 300 740 4.27 / 956.57 3 3
Average= 4.83
(KJ/cycle)

Cycle 210 GMT 17/ 6/2023 7: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.28 21 14.93 454 142 0.14 / 947.96 3 3
2 7 2001.84 44 14.04 2958 1827 1.97 / 949.79 3 3
3 13 1735.56 22 14.12 2620 814 2.78 / 950.60 2 3
4 13 1012.08 22 14.38 1688 534 3.32 / 951.14 2 3
5 13 438.92 22 14.66 945 305 3.62 / 951.44 2 3
6 13 15.76 22 14.95 323 106 3.73 / 951.55 3 3
7 8 0.00 165 14.92 305 751 4.48 / 952.30 3 3
Average= 4.83
(KJ/cycle)

Cycle 209 GMT 7/ 6/2023 7:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.20 21 14.94 461 145 0.14 / 943.50 3 3
2 3 1026.48 1 14.94 1853 28 0.17 / 943.53 2 3
3 7 2003.36 44 14.03 2976 1837 2.01 / 945.36 3 3
4 13 1566.72 22 14.17 2402 749 2.76 / 946.11 2 3
5 13 1004.48 22 14.38 1657 524 3.28 / 946.64 2 3
6 13 427.80 22 14.66 943 304 3.59 / 946.94 2 3
7 13 62.56 22 14.92 393 129 3.72 / 947.07 3 3
8 8 0.04 165 14.93 304 749 4.46 / 947.82 3 3
Average= 4.84
(KJ/cycle)

Cycle 208 GMT 28/ 5/2023 7:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.08 21 14.95 447 140 0.14 / 939.18 3 3
2 7 2007.08 44 14.03 2992 1847 1.99 / 941.03 3 3
3 13 1478.20 22 14.19 2287 714 2.70 / 941.74 2 3
4 13 919.12 22 14.42 1550 492 3.19 / 942.23 2 3
5 13 365.64 22 14.70 857 277 3.47 / 942.51 2 3
6 13 26.72 22 14.95 336 111 3.58 / 942.62 3 3
7 8 0.08 165 14.93 299 737 4.32 / 943.36 3 4
Average= 4.84
(KJ/cycle)

Cycle 207 GMT 18/ 5/2023 6:56: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.28 22 14.93 449 147 0.15 / 934.75 3 3
2 7 2003.24 44 14.04 2977 1839 1.99 / 936.58 3 3
3 13 1584.48 22 14.17 2419 754 2.74 / 937.34 2 3
4 13 1006.92 22 14.38 1663 526 3.27 / 937.86 2 3
5 13 427.64 22 14.66 942 304 3.57 / 938.17 2 3
6 13 63.16 22 14.92 398 131 3.70 / 938.30 3 3
7 8 0.04 165 14.93 300 739 4.44 / 939.04 3 3
Average= 4.84
(KJ/cycle)

Cycle 206 GMT 8/ 5/2023 7: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.40 21 14.94 459 144 0.14 / 930.34 3 3
2 7 2004.52 44 14.04 2983 1843 1.99 / 932.18 3 3
3 13 1595.44 22 14.16 2451 764 2.75 / 932.94 2 3
4 13 875.72 22 14.46 1469 467 3.22 / 933.41 2 3
5 13 450.36 22 14.65 968 312 3.53 / 933.72 2 3
6 13 66.92 22 14.92 403 132 3.66 / 933.85 3 3
7 8 -0.04 165 14.93 302 744 4.41 / 934.60 3 3
Average= 4.84
(KJ/cycle)

Cycle 205 GMT 28/ 4/2023 7: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.32 21 14.95 452 142 0.14 / 925.82 3 3
2 7 2003.64 44 14.04 2968 1834 1.98 / 927.66 3 3
3 13 1746.08 22 14.11 2631 817 2.79 / 928.47 2 3
4 13 1017.64 22 14.38 1670 528 3.32 / 929.00 2 3
5 13 443.40 22 14.66 952 307 3.63 / 929.31 2 3
6 13 66.96 22 14.92 406 133 3.76 / 929.44 3 3
7 8 -0.08 165 14.93 305 751 4.51 / 930.19 3 3
Average= 4.84
(KJ/cycle)

Cycle 204 GMT 18/ 4/2023 7: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.56 21 14.95 452 142 0.14 / 921.45 3 3
2 7 2004.00 44 14.05 2967 1834 1.98 / 923.28 3 3
3 13 1599.04 22 14.17 2438 760 2.74 / 924.04 2 3
4 13 914.12 22 14.43 1540 489 3.23 / 924.53 2 3
5 13 357.80 22 14.72 843 273 3.50 / 924.81 2 3
6 13 47.76 22 14.94 378 124 3.62 / 924.93 3 3
7 8 0.04 165 14.93 304 749 4.37 / 925.68 3 4
Average= 4.85
(KJ/cycle)

Cycle 203 GMT 8/ 4/2023 6:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.84 21 14.94 443 139 0.14 / 917.08 3 3
2 7 2002.24 44 14.03 2986 1843 1.98 / 918.93 3 3
3 13 1607.36 22 14.16 2445 762 2.74 / 919.69 2 3
4 13 906.40 22 14.45 1523 484 3.23 / 920.17 2 3
5 13 346.40 22 14.73 821 266 3.49 / 920.44 2 3
6 13 48.56 22 14.94 378 124 3.62 / 920.56 3 3
7 8 0.08 165 14.94 302 744 4.36 / 921.31 3 3
Average= 4.85
(KJ/cycle)

Cycle 202 GMT 29/ 3/2023 6:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.16 22 14.95 448 147 0.15 / 912.58 3 3
2 3 966.60 -1 15.37 0 0 0.00 / 912.58 3 3
3 7 2003.20 45 14.04 2974 1879 2.03 / 914.46 3 3
4 13 1599.44 22 14.17 2429 757 2.78 / 915.21 2 3
5 13 1041.76 22 14.36 1717 542 3.33 / 915.76 2 3
6 13 439.92 22 14.66 958 309 3.63 / 916.07 2 3
7 13 66.80 22 14.92 406 133 3.77 / 916.20 3 3
8 8 0.08 165 14.93 303 746 4.51 / 916.95 3 3
Average= 4.85
(KJ/cycle)

Cycle 201 GMT 19/ 3/2023 6:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.32 20 14.95 463 138 0.14 / 907.98 3 3
2 10 1026.40 3 14.75 1755 78 0.22 / 908.05 3 3
3 3 964.40 -1 15.34 0 0 0.08 / 908.05 3 3
4 3 1026.16 1 14.96 1839 28 0.24 / 908.08 2 3
5 7 2004.20 44 14.04 2966 1832 2.08 / 909.91 3 3
6 13 1733.52 22 14.11 2631 817 2.89 / 910.73 2 3
7 13 1009.64 22 14.40 1661 526 3.42 / 911.26 2 3
8 13 423.68 22 14.68 932 301 3.72 / 911.56 3 3
9 13 64.88 22 14.93 399 131 3.85 / 911.69 3 3
10 8 0.00 165 14.94 301 742 4.59 / 912.43 3 3
Average= 4.85
(KJ/cycle)

Cycle 200 GMT 9/ 3/2023 6:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.36 22 14.95 446 147 0.15 / 903.59 3 3
2 3 949.76 -1 15.36 0 0 0.00 / 903.59 3 3
3 7 2004.16 44 14.04 2971 1835 1.98 / 905.43 3 3
4 13 1590.60 22 14.18 2418 754 2.74 / 906.18 2 3
5 13 1019.80 22 14.39 1680 532 3.27 / 906.72 2 3
6 13 330.84 22 14.74 803 260 3.53 / 906.98 2 3
7 13 44.44 22 14.95 368 121 3.65 / 907.10 3 3
8 8 0.04 165 14.93 301 741 4.39 / 907.84 3 3
Average= 4.85
(KJ/cycle)

Cycle 199 GMT 27/ 2/2023 6:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.72 22 14.94 468 154 0.15 / 898.86 3 3
2 7 2001.40 44 14.05 2964 1832 1.99 / 900.69 3 3
3 13 1592.56 22 14.18 2418 754 2.74 / 901.44 2 3
4 13 1018.32 22 14.39 1668 528 3.27 / 901.97 2 3
5 13 319.08 22 14.75 788 256 3.52 / 902.23 2 3
6 13 78.64 22 14.92 422 139 3.66 / 902.37 3 3
7 8 0.12 165 14.93 303 746 4.41 / 903.11 3 4
8 14 0.12 75 14.90 300 335 4.74 / 903.45 3 6
Average= 4.86
(KJ/cycle)

Cycle 198 GMT 17/ 2/2023 6:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.28 22 14.94 458 151 0.15 / 894.38 3 3
2 7 2008.08 44 14.05 2968 1835 1.99 / 896.21 3 3
3 13 1601.92 22 14.17 2437 760 2.75 / 896.97 2 3
4 13 1035.68 22 14.37 1709 540 3.29 / 897.51 2 3
5 13 433.36 22 14.67 944 305 3.59 / 897.82 2 3
6 13 58.40 22 14.93 389 128 3.72 / 897.95 3 3
7 8 0.08 165 14.93 307 756 4.47 / 898.70 3 3
Average= 4.86
(KJ/cycle)

Cycle 197 GMT 7/ 2/2023 6:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.84 22 14.96 460 151 0.15 / 889.94 3 3
2 7 2002.68 44 14.05 2958 1829 1.98 / 891.77 3 3
3 13 1735.48 22 14.12 2637 819 2.80 / 892.58 2 3
4 13 868.28 22 14.47 1482 472 3.27 / 893.06 2 3
5 13 444.52 22 14.67 960 310 3.58 / 893.37 2 3
6 13 38.08 22 14.96 359 118 3.70 / 893.48 3 3
7 8 -0.04 165 14.94 302 744 4.44 / 894.23 3 3
Average= 4.86
(KJ/cycle)

Cycle 196 GMT 28/ 1/2023 6:50: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.24 22 14.95 461 152 0.15 / 885.53 3 3
2 7 2005.96 44 14.05 2965 1833 1.98 / 887.36 3 3
3 13 1594.80 22 14.18 2453 765 2.75 / 888.13 2 3
4 13 1031.64 22 14.39 1688 534 3.28 / 888.66 2 3
5 13 328.24 22 14.75 798 259 3.54 / 888.92 3 3
6 13 41.68 22 14.96 361 119 3.66 / 889.04 3 3
7 8 0.00 165 14.94 303 747 4.41 / 889.79 3 3
Average= 4.86
(KJ/cycle)

Cycle 195 GMT 18/ 1/2023 6:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.88 21 14.96 463 145 0.15 / 880.93 3 3
2 3 1025.40 1 14.99 1804 27 0.17 / 880.95 2 3
3 3 1015.64 1 15.06 1813 27 0.20 / 880.98 2 3
4 7 2002.16 44 14.05 2969 1835 2.04 / 882.82 3 3
5 13 1736.00 22 14.13 2621 815 2.85 / 883.63 2 3
6 13 997.88 22 14.40 1657 525 3.37 / 884.16 2 3
7 13 560.92 22 14.61 1096 352 3.73 / 884.51 2 3
8 13 56.68 22 14.95 384 126 3.85 / 884.63 3 3
9 8 0.04 165 14.95 301 742 4.60 / 885.38 3 3
Average= 4.86
(KJ/cycle)

Cycle 194 GMT 8/ 1/2023 6:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.00 22 14.95 467 154 0.15 / 876.50 3 3
2 7 2005.08 44 14.05 2972 1837 1.99 / 878.34 3 3
3 13 1591.28 22 14.19 2434 760 2.75 / 879.10 2 3
4 13 1021.00 22 14.40 1672 530 3.28 / 879.63 2 3
5 13 436.84 22 14.68 943 305 3.58 / 879.93 2 3
6 13 15.04 22 14.97 322 106 3.69 / 880.04 3 3
7 8 0.12 165 14.94 302 744 4.44 / 880.78 3 3
Average= 4.87
(KJ/cycle)

Cycle 193 GMT 29/12/2022 6:38:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.04 22 14.95 468 154 0.15 / 872.00 3 3
2 7 2004.08 44 14.05 2972 1837 1.99 / 873.84 3 3
3 13 1733.64 22 14.13 2619 814 2.81 / 874.65 2 3
4 13 1004.60 22 14.41 1652 524 3.33 / 875.18 2 3
5 13 439.12 22 14.68 956 309 3.64 / 875.49 2 3
6 13 30.68 22 14.96 345 114 3.75 / 875.60 3 3
7 8 -0.04 165 14.94 302 744 4.50 / 876.34 3 5
Average= 4.87
(KJ/cycle)

Cycle 192 GMT 19/12/2022 6:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.24 21 14.96 448 141 0.14 / 867.46 3 3
2 3 1023.88 1 14.98 1844 28 0.17 / 867.49 2 3
3 7 2005.12 44 14.05 2979 1842 2.01 / 869.33 3 3
4 13 1736.16 22 14.14 2618 814 2.82 / 870.15 2 3
5 13 1000.72 22 14.40 1661 526 3.35 / 870.67 2 3
6 13 417.24 22 14.69 922 298 3.65 / 870.97 2 3
7 13 28.56 22 14.96 353 116 3.76 / 871.09 3 3
8 8 0.16 165 14.94 309 762 4.53 / 871.85 3 7
Average= 4.87
(KJ/cycle)

Cycle 191 GMT 9/12/2022 6:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.32 21 14.95 463 145 0.15 / 863.14 3 3
2 7 2003.72 44 14.04 2978 1840 1.99 / 864.98 3 3
3 13 1595.08 22 14.18 2442 762 2.75 / 865.74 2 3
4 13 1015.40 22 14.40 1672 530 3.28 / 866.27 2 3
5 13 433.60 22 14.68 949 306 3.58 / 866.58 2 3
6 8 0.12 165 14.95 302 745 4.33 / 867.32 3 3
Average= 4.87
(KJ/cycle)

Cycle 190 GMT 29/11/2022 6: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.32 21 14.95 463 145 0.15 / 858.67 3 3
2 7 2006.68 44 14.05 2967 1834 1.98 / 860.50 3 3
3 13 1739.12 22 14.13 2606 810 2.79 / 861.31 2 3
4 13 1013.24 22 14.40 1666 528 3.32 / 861.84 2 3
5 13 421.08 22 14.69 924 299 3.62 / 862.14 2 3
6 13 30.56 22 14.97 346 114 3.73 / 862.25 3 3
7 8 0.08 165 14.95 302 745 4.47 / 862.99 3 3
Average= 4.88
(KJ/cycle)

Cycle 189 GMT 19/11/2022 6: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.32 21 14.96 453 142 0.14 / 854.26 3 3
2 3 1015.92 1 15.02 1814 27 0.17 / 854.29 2 3
3 7 2003.84 44 14.05 2982 1843 2.01 / 856.13 3 3
4 13 1741.52 22 14.14 2637 820 2.83 / 856.95 2 3
5 13 1006.92 22 14.41 1652 524 3.36 / 857.47 2 3
6 13 429.28 22 14.69 930 301 3.66 / 857.77 2 3
7 8 0.12 165 14.95 302 745 4.40 / 858.52 3 4
Average= 4.88
(KJ/cycle)

Cycle 188 GMT 9/11/2022 6: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.84 21 14.96 472 148 0.15 / 849.97 3 3
2 7 2004.64 44 14.05 2960 1830 1.98 / 851.80 3 3
3 13 1604.80 22 14.17 2467 769 2.75 / 852.56 2 3
4 13 1040.96 22 14.39 1700 538 3.29 / 853.10 2 3
5 13 344.48 22 14.75 822 267 3.55 / 853.37 2 3
6 8 0.12 165 14.96 303 748 4.30 / 854.12 3 3
Average= 4.88
(KJ/cycle)

Cycle 187 GMT 30/10/2022 5:37: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.36 21 14.96 454 143 0.14 / 845.64 3 3
2 7 2005.40 44 14.05 2988 1847 1.99 / 847.49 3 3
3 13 1609.76 22 14.18 2458 767 2.76 / 848.26 2 3
4 13 908.36 22 14.46 1545 491 3.25 / 848.75 2 3
5 13 475.84 22 14.66 988 319 3.57 / 849.07 2 3
6 8 0.04 165 14.96 303 748 4.31 / 849.82 3 3
Average= 4.88
(KJ/cycle)

Cycle 186 GMT 20/10/2022 5:30: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.08 22 14.96 457 150 0.15 / 841.32 3 3
2 7 2005.40 44 14.05 2965 1833 1.98 / 843.16 3 3
3 13 1611.08 22 14.18 2452 765 2.75 / 843.92 2 3
4 13 1022.84 22 14.40 1681 533 3.28 / 844.46 2 3
5 13 429.96 22 14.69 934 302 3.58 / 844.76 2 3
6 8 0.24 165 14.96 302 745 4.33 / 845.50 3 4
Average= 4.89
(KJ/cycle)

Cycle 185 GMT 10/10/2022 5:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.48 22 14.95 457 150 0.15 / 836.95 3 3
2 7 2001.36 44 14.06 2969 1837 1.99 / 838.79 3 3
3 13 1592.96 22 14.19 2431 759 2.75 / 839.55 2 3
4 13 1012.12 22 14.41 1655 525 3.27 / 840.07 2 3
5 13 309.28 22 14.78 766 249 3.52 / 840.32 2 3
6 13 13.96 22 14.98 321 106 3.63 / 840.43 3 3
7 8 0.04 165 14.95 303 747 4.37 / 841.17 3 3
Average= 4.89
(KJ/cycle)

Cycle 184 GMT 30/ 9/2022 5:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.76 22 14.97 467 154 0.15 / 832.60 3 3
2 7 2002.52 44 14.04 3002 1855 2.01 / 834.46 3 3
3 13 1594.96 22 14.19 2446 764 2.77 / 835.22 2 3
4 13 1011.44 22 14.40 1679 532 3.30 / 835.75 2 3
5 13 424.12 22 14.69 928 300 3.60 / 836.05 2 3
6 8 0.08 165 14.96 303 748 4.35 / 836.80 3 3
Average= 4.89
(KJ/cycle)

Cycle 183 GMT 20/ 9/2022 5:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.96 22 14.96 466 153 0.15 / 828.32 3 3
2 7 2002.96 45 14.05 2976 1882 2.03 / 830.20 3 3
3 13 1599.68 22 14.20 2428 759 2.79 / 830.96 2 3
4 13 888.16 22 14.48 1501 478 3.27 / 831.44 2 3
5 13 336.08 22 14.76 808 262 3.53 / 831.70 3 3
6 8 0.16 165 14.96 303 748 4.28 / 832.45 3 3
Average= 4.90
(KJ/cycle)

Cycle 182 GMT 10/ 9/2022 5:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.52 21 14.96 453 142 0.14 / 823.85 3 3
2 7 2004.08 44 14.05 2990 1848 1.99 / 825.70 3 3
3 13 1616.60 22 14.19 2463 769 2.76 / 826.47 2 3
4 13 1034.32 22 14.40 1691 536 3.30 / 827.00 2 3
5 13 451.84 22 14.68 963 311 3.61 / 827.31 3 3
6 13 16.72 22 14.98 322 106 3.71 / 827.42 3 3
7 8 0.24 165 14.95 303 747 4.46 / 828.17 3 3
Average= 4.90
(KJ/cycle)

Cycle 181 GMT 31/ 8/2022 5:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.52 21 14.97 456 143 0.14 / 819.56 3 3
2 7 2004.88 44 14.05 2987 1847 1.99 / 821.41 3 3
3 13 1736.84 22 14.14 2622 816 2.81 / 822.22 2 3
4 13 883.68 22 14.48 1497 477 3.28 / 822.70 2 3
5 13 344.00 22 14.76 819 266 3.55 / 822.97 2 3
6 8 0.24 165 14.96 300 741 4.29 / 823.71 3 3
Average= 4.90
(KJ/cycle)

Cycle 180 GMT 21/ 8/2022 5:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.76 22 14.97 469 154 0.15 / 815.30 3 3
2 7 2007.56 44 14.05 2993 1850 2.00 / 817.15 3 3
3 13 1615.76 22 14.19 2462 769 2.77 / 817.92 2 3
4 13 901.68 22 14.47 1525 485 3.26 / 818.41 2 3
5 13 354.16 22 14.75 824 267 3.53 / 818.68 2 3
6 8 -0.04 165 14.97 301 743 4.27 / 819.42 3 3
Average= 4.91
(KJ/cycle)

Cycle 179 GMT 11/ 8/2022 4:56: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.96 21 14.97 455 143 0.14 / 810.91 3 3
2 7 2001.68 44 14.05 2974 1839 1.98 / 812.75 3 3
3 13 1602.24 22 14.20 2436 761 2.74 / 813.51 2 3
4 13 1166.68 22 14.34 1871 590 3.33 / 814.10 2 3
5 13 418.64 22 14.71 918 297 3.63 / 814.40 2 3
6 8 0.08 165 14.96 304 750 4.38 / 815.15 3 3
Average= 4.91
(KJ/cycle)

Cycle 178 GMT 1/ 8/2022 5: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.60 22 14.96 461 152 0.15 / 806.54 3 3
2 7 2003.68 44 14.05 2999 1854 2.01 / 808.40 3 3
3 13 1725.48 22 14.15 2603 810 2.82 / 809.21 2 3
4 13 1000.60 22 14.42 1650 523 3.34 / 809.73 2 3
5 13 413.04 22 14.71 912 295 3.63 / 810.03 2 3
6 8 0.08 165 14.97 301 743 4.38 / 810.77 3 3
Average= 4.91
(KJ/cycle)

Cycle 177 GMT 22/ 7/2022 4:56: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.48 21 14.96 478 150 0.15 / 802.01 3 3
2 7 2004.20 44 14.05 2997 1853 2.00 / 803.86 3 3
3 13 1598.72 22 14.20 2431 759 2.76 / 804.62 2 3
4 13 1027.52 22 14.41 1690 536 3.30 / 805.16 2 3
5 13 589.52 22 14.61 1138 366 3.66 / 805.52 2 3
6 13 26.24 22 14.97 340 112 3.78 / 805.64 3 3
7 8 0.08 165 14.95 306 755 4.53 / 806.39 3 4
Average= 4.92
(KJ/cycle)

Cycle 176 GMT 12/ 7/2022 5: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.16 22 14.97 462 152 0.15 / 797.70 3 3
2 7 2005.00 44 14.05 2981 1843 2.00 / 799.54 3 3
3 13 1472.56 22 14.26 2268 712 2.71 / 800.26 2 3
4 13 1053.88 22 14.39 1727 547 3.25 / 800.80 2 3
5 13 458.12 22 14.68 965 312 3.56 / 801.11 2 3
6 8 0.12 165 14.96 302 745 4.31 / 801.86 3 3
Average= 4.92
(KJ/cycle)

Cycle 175 GMT 2/ 7/2022 4:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.48 21 14.97 453 142 0.14 / 793.19 3 3
2 3 1017.84 1 15.04 1821 27 0.17 / 793.22 2 3
3 7 2003.88 44 14.06 2984 1846 2.02 / 795.06 3 3
4 13 1874.40 22 14.11 2823 876 2.89 / 795.94 2 3
5 13 1119.12 22 14.37 1804 570 3.46 / 796.51 2 3
6 13 390.48 22 14.73 883 286 3.75 / 796.79 2 3
7 8 0.16 165 14.97 306 756 4.50 / 797.55 3 3
Average= 4.92
(KJ/cycle)

Cycle 174 GMT 22/ 6/2022 4:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.16 21 14.96 448 141 0.14 / 788.75 3 3
2 7 2004.64 44 14.05 2987 1847 1.99 / 790.60 3 3
3 13 1735.00 22 14.16 2624 817 2.80 / 791.41 2 3
4 13 1146.92 22 14.35 1853 585 3.39 / 792.00 2 3
5 13 415.52 22 14.71 911 295 3.68 / 792.29 2 3
6 8 0.08 165 14.96 305 753 4.44 / 793.05 3 3
Average= 4.93
(KJ/cycle)

Cycle 173 GMT 12/ 6/2022 4:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.60 21 14.96 464 146 0.15 / 784.41 3 3
2 7 2006.08 44 14.06 2974 1840 1.99 / 786.25 3 3
3 13 1602.76 22 14.19 2466 770 2.76 / 787.02 2 3
4 13 1016.00 22 14.41 1684 534 3.29 / 787.56 2 3
5 13 426.40 22 14.70 935 302 3.59 / 787.86 2 3
6 8 0.04 165 14.96 304 750 4.34 / 788.61 3 3
Average= 4.93
(KJ/cycle)

Cycle 172 GMT 2/ 6/2022 4:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.68 21 14.97 461 145 0.14 / 779.90 3 3
2 7 2002.24 44 14.05 2987 1847 1.99 / 781.75 3 3
3 13 1736.36 22 14.17 2608 813 2.80 / 782.56 2 3
4 13 999.68 22 14.43 1646 523 3.33 / 783.08 2 3
5 13 431.28 22 14.70 935 302 3.63 / 783.38 2 3
6 13 61.16 22 14.95 392 129 3.76 / 783.51 3 3
7 8 0.12 165 14.95 305 752 4.51 / 784.27 3 3
Average= 4.93
(KJ/cycle)

Cycle 171 GMT 23/ 5/2022 4:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.32 18 14.97 450 121 0.12 / 775.58 3 3
2 10 1057.64 3 14.75 1796 79 0.20 / 775.66 3 3
3 7 2004.48 44 14.06 3007 1860 2.06 / 777.52 3 3
4 13 1478.40 22 14.25 2281 715 2.78 / 778.24 2 3
5 13 934.60 22 14.45 1571 499 3.28 / 778.74 2 3
6 13 363.28 22 14.74 848 275 3.55 / 779.01 2 3
7 8 0.08 165 14.97 300 741 4.29 / 779.76 3 3
Average= 4.94
(KJ/cycle)

Cycle 170 GMT 13/ 5/2022 4:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.84 31 14.96 453 210 0.21 / 771.10 3 3
2 3 635.68 -6 15.39 0 0 0.00 / 771.10 3 3
3 3 875.40 -2 15.41 0 0 0.00 / 771.10 3 3
4 7 2006.12 44 14.06 2984 1846 2.06 / 772.94 3 3
5 13 1879.68 22 14.11 2811 873 2.93 / 773.82 2 3
6 13 866.12 22 14.51 1468 469 3.40 / 774.28 2 3
7 13 445.08 22 14.69 950 307 3.70 / 774.59 2 3
8 13 66.16 22 14.96 401 132 3.84 / 774.72 3 3
9 8 0.12 165 14.96 300 741 4.58 / 775.46 3 3
Average= 4.94
(KJ/cycle)

Cycle 169 GMT 3/ 5/2022 3:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.16 30 14.98 400 180 0.18 / 766.59 3 3
2 3 1043.92 1 14.95 1758 26 0.21 / 766.61 2 3
3 7 2004.48 44 14.11 2854 1772 1.98 / 768.38 3 3
4 13 1739.84 22 14.20 2507 783 2.76 / 769.17 2 3
5 13 1038.76 22 14.42 1675 531 3.29 / 769.70 2 3
6 13 478.44 22 14.68 988 319 3.61 / 770.02 2 3
7 13 45.64 22 14.98 370 122 3.73 / 770.14 3 3
8 8 0.08 165 14.96 303 748 4.48 / 770.89 3 3
Average= 4.94
(KJ/cycle)

Cycle 168 GMT 23/ 4/2022 3:50: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.28 22 14.98 405 133 0.13 / 761.99 3 3
2 10 1019.00 6 14.71 1720 152 0.29 / 762.14 3 3
3 10 1050.92 3 14.75 1738 77 0.36 / 762.22 3 3
4 7 2003.28 45 14.12 2842 1806 2.17 / 764.03 3 3
5 13 1596.04 22 14.25 2350 737 2.90 / 764.76 2 3
6 13 1032.76 22 14.43 1639 520 3.43 / 765.28 2 3
7 13 348.60 22 14.77 809 263 3.69 / 765.55 2 3
8 13 48.52 22 14.98 369 122 3.81 / 765.67 3 3
9 8 0.08 165 14.97 299 739 4.55 / 766.41 3 3
Average= 4.94
(KJ/cycle)

Cycle 167 GMT 13/ 4/2022 3:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.20 22 14.97 458 151 0.15 / 757.66 3 3
2 7 2003.32 44 14.09 2923 1812 1.96 / 759.47 3 3
3 13 1589.80 22 14.23 2362 739 2.70 / 760.21 2 3
4 13 1008.96 22 14.44 1620 515 3.22 / 760.72 2 3
5 13 435.52 22 14.72 911 295 3.51 / 761.02 2 3
6 13 16.64 22 15.00 310 102 3.61 / 761.12 3 3
7 8 0.12 165 14.97 298 736 4.35 / 761.86 3 3
Average= 4.95
(KJ/cycle)

Cycle 166 GMT 3/ 4/2022 3:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.72 22 14.98 451 149 0.15 / 753.24 3 3
2 7 2003.20 44 14.04 3051 1885 2.03 / 755.13 3 3
3 13 1604.32 22 14.19 2503 781 2.81 / 755.91 2 3
4 13 1022.12 22 14.41 1729 548 3.36 / 756.46 2 3
5 13 419.56 22 14.71 932 302 3.66 / 756.76 2 3
6 8 0.20 165 14.97 302 746 4.41 / 757.51 3 3
Average= 4.95
(KJ/cycle)

Cycle 165 GMT 24/ 3/2022 3:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.52 21 14.97 460 145 0.14 / 748.85 3 3
2 3 1019.20 1 15.03 1884 28 0.17 / 748.87 2 3
3 7 2004.28 44 14.04 3046 1882 2.05 / 750.76 3 3
4 13 1604.04 22 14.21 2508 784 2.84 / 751.54 2 3
5 13 901.20 22 14.47 1570 500 3.34 / 752.04 2 3
6 13 450.84 22 14.69 976 315 3.65 / 752.36 2 3
7 8 0.04 165 14.97 300 741 4.39 / 753.10 3 3
Average= 4.95
(KJ/cycle)

Cycle 164 GMT 14/ 3/2022 4: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.64 22 14.98 452 149 0.15 / 744.39 3 3
2 7 2001.60 44 14.11 2869 1781 1.93 / 746.17 3 3
3 13 1727.84 22 14.20 2527 789 2.72 / 746.96 2 3
4 13 1137.52 22 14.39 1795 568 3.29 / 747.53 2 3
5 13 421.36 22 14.72 933 302 3.59 / 747.83 2 3
6 13 57.36 22 14.97 385 127 3.72 / 747.96 3 3
7 8 0.00 165 14.96 302 745 4.46 / 748.70 3 3
Average= 4.96
(KJ/cycle)

Cycle 163 GMT 4/ 3/2022 4:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.52 21 14.98 454 143 0.14 / 739.98 3 3
2 7 2005.04 44 14.04 3052 1885 2.03 / 741.87 3 3
3 13 1592.72 22 14.21 2484 777 2.80 / 742.64 2 3
4 13 882.40 22 14.49 1516 483 3.29 / 743.13 2 3
5 13 330.00 22 14.78 810 263 3.55 / 743.39 2 3
6 13 20.72 22 14.99 330 109 3.66 / 743.50 3 3
7 8 0.04 165 14.97 300 741 4.40 / 744.24 3 11
Average= 4.96
(KJ/cycle)

Cycle 162 GMT 22/ 2/2022 4: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.04 21 14.98 474 149 0.15 / 735.65 3 3
2 7 2002.92 44 14.04 3066 1894 2.04 / 737.54 3 3
3 13 1590.00 22 14.20 2499 781 2.82 / 738.32 2 3
4 13 881.44 22 14.48 1556 496 3.32 / 738.82 2 3
5 13 327.52 22 14.78 816 265 3.58 / 739.08 2 3
6 8 0.12 165 14.98 306 756 4.34 / 739.84 3 3
Average= 4.97
(KJ/cycle)

Cycle 161 GMT 12/ 2/2022 3:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.40 21 14.96 471 148 0.15 / 731.18 3 3
2 7 2004.12 44 14.03 3076 1899 2.05 / 733.08 3 3
3 13 1752.68 22 14.14 2703 841 2.89 / 733.92 2 3
4 13 1012.28 22 14.41 1733 549 3.44 / 734.47 2 3
5 13 307.96 22 14.79 791 257 3.69 / 734.73 2 3
6 8 0.08 165 14.97 310 766 4.46 / 735.50 3 3
Average= 4.97
(KJ/cycle)

Cycle 160 GMT 2/ 2/2022 3:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.28 21 14.98 461 145 0.15 / 726.67 3 3
2 7 2011.12 44 14.05 3050 1886 2.03 / 728.56 3 3
3 13 1474.68 22 14.25 2344 735 2.77 / 729.29 2 3
4 13 1032.52 22 14.40 1752 555 3.32 / 729.85 2 3
5 13 429.80 22 14.70 952 308 3.63 / 730.15 2 3
6 13 25.60 22 14.98 349 115 3.74 / 730.27 3 3
7 8 -0.04 165 14.96 311 768 4.51 / 731.04 3 3
Average= 4.97
(KJ/cycle)

Cycle 159 GMT 23/ 1/2022 3:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.76 21 14.98 457 144 0.14 / 722.23 3 3
2 3 1021.04 1 15.02 1872 28 0.17 / 722.25 2 3
3 7 2001.60 44 14.06 3026 1872 2.04 / 724.13 3 3
4 13 1586.16 22 14.21 2452 767 2.81 / 724.89 2 3
5 13 1144.96 22 14.37 1856 587 3.40 / 725.48 2 3
6 13 409.04 22 14.73 896 290 3.69 / 725.77 2 3
7 8 0.16 165 14.98 306 756 4.44 / 726.53 3 3
Average= 4.98
(KJ/cycle)

Cycle 158 GMT 13/ 1/2022 3: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.08 22 14.98 446 147 0.15 / 717.80 3 3
2 7 2003.60 44 14.06 3020 1868 2.02 / 719.67 3 3
3 13 1593.64 22 14.21 2510 785 2.80 / 720.46 2 3
4 13 1141.08 22 14.36 1872 591 3.39 / 721.05 2 3
5 13 372.56 22 14.75 877 285 3.68 / 721.33 2 3
6 8 0.16 165 14.98 303 749 4.42 / 722.08 3 3
Average= 4.98
(KJ/cycle)

Cycle 157 GMT 3/ 1/2022 3:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.68 21 14.98 461 145 0.15 / 713.36 3 3
2 7 2002.08 44 14.05 3035 1876 2.02 / 715.23 3 3
3 13 1583.00 22 14.22 2475 774 2.80 / 716.01 2 3
4 13 1005.64 22 14.43 1703 541 3.34 / 716.55 2 3
5 13 289.40 22 14.82 753 246 3.58 / 716.79 3 3
6 13 27.36 22 15.00 340 112 3.69 / 716.91 3 3
7 8 -0.04 165 14.97 304 751 4.44 / 717.66 3 3
Average= 4.98
(KJ/cycle)

Cycle 156 GMT 24/12/2021 3: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.48 21 14.99 450 142 0.14 / 708.97 3 3
2 7 2002.92 44 14.06 3027 1873 2.01 / 710.85 3 3
3 13 1589.88 22 14.21 2477 774 2.79 / 711.62 2 3
4 13 1014.64 22 14.43 1711 543 3.33 / 712.16 2 3
5 13 414.40 22 14.73 924 299 3.63 / 712.46 2 3
6 8 0.04 165 14.98 303 749 4.38 / 713.21 3 3
Average= 4.99
(KJ/cycle)

Cycle 155 GMT 14/12/2021 3:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.40 21 14.99 457 144 0.14 / 704.60 3 3
2 7 2003.88 44 14.06 3033 1876 2.02 / 706.47 3 3
3 13 1731.76 22 14.17 2674 834 2.85 / 707.31 2 3
4 13 858.00 22 14.52 1502 480 3.33 / 707.79 2 3
5 13 417.56 22 14.73 925 300 3.63 / 708.09 2 3
6 8 0.00 165 14.99 301 744 4.38 / 708.83 3 3
Average= 4.99
(KJ/cycle)

Cycle 154 GMT 4/12/2021 3: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.24 21 14.99 460 145 0.14 / 700.24 3 3
2 7 2002.72 44 14.06 3050 1887 2.03 / 702.13 3 3
3 13 1736.80 22 14.16 2685 836 2.87 / 702.96 2 3
4 13 876.40 22 14.50 1517 484 3.35 / 703.45 2 3
5 13 323.28 22 14.80 802 261 3.61 / 703.71 3 3
6 8 0.08 165 14.99 302 747 4.36 / 704.45 3 3
Average= 5.00
(KJ/cycle)

Cycle 153 GMT 24/11/2021 3: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.44 21 14.98 467 147 0.15 / 695.79 3 3
2 7 2009.32 44 14.06 3033 1876 2.02 / 697.67 3 3
3 13 1750.24 22 14.15 2720 847 2.87 / 698.51 2 3
4 13 1007.32 22 14.44 1698 539 3.41 / 699.05 2 3
5 13 407.64 22 14.74 911 295 3.70 / 699.35 2 3
6 8 0.20 165 14.99 301 744 4.45 / 700.09 3 3
Average= 5.00
(KJ/cycle)

Cycle 152 GMT 14/11/2021 3: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.72 21 14.98 450 142 0.14 / 691.48 3 3
2 7 2004.80 44 14.06 3046 1884 2.03 / 693.36 3 3
3 13 1586.04 22 14.22 2491 779 2.81 / 694.14 2 3
4 13 895.00 22 14.49 1547 493 3.30 / 694.63 2 3
5 13 326.08 22 14.79 803 261 3.56 / 694.90 3 3
6 8 0.20 165 14.99 303 749 4.31 / 695.64 3 3
Average= 5.00
(KJ/cycle)

Cycle 151 GMT 4/11/2021 2:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.72 21 14.98 466 147 0.15 / 687.12 3 3
2 7 2003.04 44 14.06 3051 1887 2.03 / 689.01 3 3
3 13 1464.36 22 14.27 2314 726 2.76 / 689.74 2 3
4 13 912.12 22 14.48 1583 504 3.26 / 690.24 2 3
5 13 465.00 22 14.69 996 322 3.59 / 690.56 2 3
6 8 -0.04 165 14.98 312 771 4.36 / 691.34 3 4
Average= 5.01
(KJ/cycle)

Cycle 150 GMT 25/10/2021 2:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.00 21 14.98 452 142 0.14 / 682.82 3 3
2 7 2001.72 44 14.07 3032 1877 2.02 / 684.70 3 3
3 13 1581.16 22 14.23 2468 773 2.79 / 685.47 2 3
4 13 881.28 22 14.50 1541 492 3.28 / 685.97 2 3
5 13 310.76 22 14.80 786 256 3.54 / 686.22 2 3
6 8 0.08 165 14.98 306 756 4.30 / 686.98 3 5
Average= 5.01
(KJ/cycle)

Cycle 149 GMT 15/10/2021 2:51: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.96 21 14.99 460 145 0.14 / 678.45 3 3
2 3 1015.96 1 15.07 1879 28 0.17 / 678.48 2 3
3 7 2003.16 44 14.06 3053 1889 2.06 / 680.37 3 3
4 13 1600.56 22 14.22 2501 782 2.84 / 681.15 2 3
5 13 906.68 22 14.49 1553 495 3.34 / 681.64 2 3
6 13 340.72 22 14.78 845 275 3.61 / 681.92 2 3
7 8 0.08 165 14.98 309 764 4.38 / 682.68 3 3
Average= 5.02
(KJ/cycle)

Cycle 148 GMT 5/10/2021 2:41: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.36 21 14.99 452 142 0.14 / 674.11 3 3
2 7 2002.16 44 14.06 3028 1873 2.02 / 675.98 3 3
3 13 1609.36 22 14.22 2508 785 2.80 / 676.77 2 3
4 13 926.60 22 14.48 1589 506 3.31 / 677.28 2 3
5 13 350.84 22 14.78 845 275 3.58 / 677.55 2 3
6 8 0.04 165 14.99 305 754 4.34 / 678.30 3 3
Average= 5.02
(KJ/cycle)

Cycle 147 GMT 25/ 9/2021 2:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.40 21 14.99 459 144 0.14 / 669.76 3 3
2 7 2004.60 44 14.07 3045 1885 2.03 / 671.64 3 3
3 13 1589.92 22 14.23 2486 778 2.81 / 672.42 2 3
4 13 1013.96 22 14.44 1706 542 3.35 / 672.96 2 3
5 13 303.16 22 14.82 773 252 3.60 / 673.21 3 3
6 8 0.12 165 14.99 305 754 4.36 / 673.97 3 3
Average= 5.03
(KJ/cycle)

Cycle 146 GMT 15/ 9/2021 2:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.64 21 15.00 448 141 0.14 / 665.45 3 3
2 7 2003.44 44 14.06 3041 1881 2.02 / 667.33 3 3
3 13 1597.36 22 14.23 2488 779 2.80 / 668.11 2 3
4 13 900.68 22 14.51 1540 492 3.29 / 668.60 2 3
5 13 317.04 22 14.80 795 259 3.55 / 668.86 2 3
6 8 0.20 165 14.99 304 752 4.30 / 669.61 3 6
Average= 5.03
(KJ/cycle)

Cycle 145 GMT 5/ 9/2021 2:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.16 21 14.99 464 146 0.15 / 661.07 3 3
2 7 2005.32 44 14.06 3051 1887 2.03 / 662.96 3 3
3 13 1606.72 22 14.22 2514 786 2.82 / 663.75 2 3
4 13 1021.28 22 14.44 1716 545 3.37 / 664.29 2 3
5 13 306.52 22 14.82 780 254 3.62 / 664.55 2 3
6 8 0.08 165 14.99 308 762 4.38 / 665.31 3 3
Average= 5.04
(KJ/cycle)

Cycle 144 GMT 26/ 8/2021 2:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.36 21 14.98 466 147 0.15 / 656.59 3 3
2 7 2004.08 44 14.06 3066 1897 2.04 / 658.49 3 3
3 13 1725.56 22 14.19 2677 836 2.88 / 659.33 2 3
4 13 990.44 22 14.45 1675 532 3.41 / 659.86 2 3
5 13 414.48 22 14.74 924 300 3.71 / 660.16 2 3
6 8 0.12 165 14.99 311 769 4.48 / 660.93 3 3
Average= 5.05
(KJ/cycle)

Cycle 143 GMT 16/ 8/2021 2:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.24 21 15.00 446 140 0.14 / 652.27 3 3
2 7 2006.64 44 14.07 3033 1878 2.02 / 654.15 3 3
3 13 1462.68 22 14.27 2311 726 2.74 / 654.88 2 3
4 13 1055.36 22 14.42 1758 558 3.30 / 655.43 2 3
5 13 318.12 22 14.81 795 259 3.56 / 655.69 2 3
6 8 0.04 165 14.99 305 754 4.31 / 656.45 3 3
Average= 5.05
(KJ/cycle)

Cycle 142 GMT 6/ 8/2021 2:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.92 21 15.00 451 142 0.14 / 647.83 3 3
2 7 2003.84 44 14.07 3056 1892 2.03 / 649.73 3 3
3 13 1732.00 22 14.18 2677 835 2.87 / 650.56 2 3
4 13 987.84 22 14.46 1666 530 3.40 / 651.09 2 3
5 13 403.40 22 14.75 908 295 3.69 / 651.39 2 3
6 8 0.08 165 15.00 302 747 4.44 / 652.13 3 3
Average= 5.06
(KJ/cycle)

Cycle 141 GMT 27/ 7/2021 2:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.28 21 14.99 463 146 0.15 / 643.54 3 3
2 7 2002.12 44 14.07 3026 1873 2.02 / 645.41 3 3
3 13 1591.60 22 14.23 2481 777 2.80 / 646.19 2 3
4 13 882.84 22 14.51 1521 486 3.28 / 646.68 2 3
5 13 324.88 22 14.80 806 262 3.54 / 646.94 2 3
6 8 0.08 165 15.00 304 752 4.30 / 647.69 3 3
Average= 5.06
(KJ/cycle)

Cycle 140 GMT 17/ 7/2021 2: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.32 21 14.99 467 147 0.15 / 639.14 3 3
2 7 2005.08 44 14.07 3047 1886 2.03 / 641.03 3 3
3 13 1602.48 22 14.23 2519 789 2.82 / 641.82 2 3
4 13 873.32 22 14.51 1532 489 3.31 / 642.30 2 3
5 13 442.12 22 14.72 976 316 3.63 / 642.62 2 3
6 8 0.08 165 14.99 313 774 4.40 / 643.40 3 3
Average= 5.07
(KJ/cycle)

Cycle 139 GMT 7/ 7/2021 1:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.80 20 14.99 449 135 0.13 / 634.75 3 3
2 3 1030.28 1 14.99 1875 28 0.16 / 634.78 2 3
3 7 2002.60 44 14.07 3039 1881 2.04 / 636.66 3 3
4 13 1592.84 22 14.23 2480 776 2.82 / 637.43 2 3
5 13 1014.08 22 14.44 1713 544 3.36 / 637.98 2 3
6 13 290.72 22 14.83 752 245 3.61 / 638.22 2 3
7 8 0.16 165 15.00 311 770 4.38 / 638.99 3 3
Average= 5.07
(KJ/cycle)

Cycle 138 GMT 27/ 6/2021 1:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.44 21 14.99 461 145 0.15 / 630.45 3 3
2 7 2003.28 44 14.07 3038 1881 2.03 / 632.33 3 3
3 13 1461.04 22 14.28 2326 731 2.76 / 633.06 2 3
4 13 1039.24 22 14.43 1733 550 3.31 / 633.61 2 3
5 13 295.40 22 14.82 764 249 3.56 / 633.86 2 3
6 8 0.04 165 15.00 305 755 4.31 / 634.61 3 3
Average= 5.08
(KJ/cycle)

Cycle 137 GMT 17/ 6/2021 1:11: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.60 21 15.00 452 142 0.14 / 626.07 3 3
2 7 2003.12 44 14.09 2973 1843 1.99 / 627.91 3 3
3 13 1589.96 22 14.25 2430 762 2.75 / 628.67 2 3
4 13 882.84 22 14.53 1511 483 3.23 / 629.16 2 3
5 13 319.44 22 14.81 803 262 3.49 / 629.42 2 3
6 13 79.40 22 14.98 423 139 3.63 / 629.56 3 3
7 8 0.08 165 14.99 301 744 4.38 / 630.30 3 3
Average= 5.08
(KJ/cycle)

Cycle 136 GMT 7/ 6/2021 0:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.84 21 15.01 452 142 0.14 / 621.69 3 3
2 7 2004.44 44 14.09 2971 1842 1.98 / 623.54 3 3
3 13 1733.76 22 14.20 2618 818 2.80 / 624.35 2 3
4 13 999.08 22 14.47 1644 523 3.33 / 624.88 2 3
5 13 417.04 22 14.74 929 301 3.63 / 625.18 2 3
6 8 0.12 165 15.00 303 750 4.38 / 625.93 3 3
Average= 5.09
(KJ/cycle)

Cycle 135 GMT 28/ 5/2021 0:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.76 22 15.01 444 147 0.15 / 617.45 3 3
2 7 2003.64 44 14.10 2959 1836 1.98 / 619.29 3 3
3 13 1468.56 22 14.30 2279 717 2.70 / 620.00 2 3
4 13 1034.48 22 14.46 1694 539 3.24 / 620.54 2 3
5 13 322.68 22 14.82 811 264 3.50 / 620.81 2 3
6 8 0.08 165 15.01 300 743 4.25 / 621.55 3 3
Average= 5.09
(KJ/cycle)

Cycle 134 GMT 18/ 5/2021 0:34: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.60 21 15.00 468 147 0.15 / 612.95 3 3
2 7 2005.00 44 14.11 2930 1819 1.97 / 614.77 3 3
3 13 1735.48 22 14.23 2551 799 2.77 / 615.57 2 3
4 13 1019.12 22 14.47 1658 528 3.29 / 616.10 2 3
5 13 434.60 22 14.74 948 307 3.60 / 616.41 2 3
6 13 67.04 22 15.00 412 136 3.74 / 616.54 3 3
7 8 0.04 165 15.00 308 762 4.50 / 617.31 3 3
Average= 5.10
(KJ/cycle)

Cycle 133 GMT 8/ 5/2021 0:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.16 21 15.02 462 146 0.15 / 608.63 3 3
2 7 2002.92 44 14.07 3061 1895 2.04 / 610.53 3 3
3 13 1471.24 22 14.29 2327 732 2.77 / 611.26 2 3
4 13 915.68 22 14.50 1585 506 3.28 / 611.77 2 3
5 13 339.64 22 14.80 840 274 3.55 / 612.04 2 3
6 8 0.24 165 15.00 310 767 4.32 / 612.81 3 3
Average= 5.11
(KJ/cycle)

Cycle 132 GMT 28/ 4/2021 0: 5: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.44 21 15.02 452 143 0.14 / 604.31 3 3
2 7 2008.12 44 14.07 3047 1886 2.03 / 606.19 3 3
3 13 1600.84 22 14.23 2523 790 2.82 / 606.98 2 3
4 13 891.48 22 14.53 1544 494 3.31 / 607.47 2 3
5 13 329.64 22 14.82 819 267 3.58 / 607.74 2 3
6 8 0.16 165 15.02 301 746 4.33 / 608.49 3 3
Average= 5.11
(KJ/cycle)

Cycle 131 GMT 18/ 4/2021 0: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.12 21 15.01 452 142 0.14 / 599.90 3 3
2 7 2004.24 44 14.08 3038 1882 2.02 / 601.79 3 3
3 13 1592.92 22 14.24 2494 781 2.81 / 602.57 2 3
4 13 1000.80 22 14.46 1712 545 3.35 / 603.11 2 3
5 13 418.52 22 14.76 930 302 3.65 / 603.41 2 3
6 8 0.08 165 15.01 302 748 4.40 / 604.16 3 3
Average= 5.12
(KJ/cycle)

Cycle 130 GMT 7/ 4/2021 23:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.40 21 15.01 448 141 0.14 / 595.45 3 3
2 7 2002.44 44 14.08 3053 1891 2.03 / 597.34 3 3
3 13 1728.36 22 14.20 2665 833 2.87 / 598.17 2 3
4 13 1001.16 22 14.47 1701 541 3.41 / 598.71 2 3
5 13 400.36 22 14.77 909 295 3.70 / 599.01 2 3
6 8 0.08 165 15.01 304 753 4.45 / 599.76 3 3
Average= 5.13
(KJ/cycle)

Cycle 129 GMT 28/ 3/2021 23:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.36 21 15.01 466 147 0.15 / 591.03 3 3
2 7 2005.76 44 14.08 3058 1894 2.04 / 592.93 3 3
3 13 1727.92 22 14.20 2685 839 2.88 / 593.77 2 3
4 13 864.72 22 14.54 1520 486 3.37 / 594.25 2 3
5 13 424.56 22 14.75 940 305 3.67 / 594.56 2 3
6 8 0.12 165 15.01 302 748 4.42 / 595.31 3 3
Average= 5.13
(KJ/cycle)

Cycle 128 GMT 18/ 3/2021 23:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.72 21 15.02 443 140 0.14 / 586.52 3 3
2 7 2006.72 44 14.08 3041 1884 2.02 / 588.41 3 3
3 13 1599.08 22 14.25 2486 779 2.80 / 589.19 2 3
4 13 1012.80 22 14.47 1715 546 3.35 / 589.73 2 3
5 13 400.52 22 14.76 904 294 3.64 / 590.03 2 3
6 13 23.92 22 15.03 339 112 3.75 / 590.14 3 3
7 8 0.04 165 15.01 303 750 4.51 / 590.89 3 3
Average= 5.14
(KJ/cycle)

Cycle 127 GMT 8/ 3/2021 23:41: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.32 22 15.02 458 151 0.15 / 582.06 3 3
2 7 2003.76 44 14.08 3040 1883 2.03 / 583.94 3 3
3 13 1732.52 22 14.20 2671 834 2.87 / 584.77 2 3
4 13 1103.48 22 14.42 1831 581 3.45 / 585.35 2 3
5 13 351.08 22 14.80 851 277 3.73 / 585.63 2 3
6 8 0.16 165 15.02 303 751 4.48 / 586.38 3 3
Average= 5.14
(KJ/cycle)

Cycle 126 GMT 26/ 2/2021 23:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.12 21 15.02 448 141 0.14 / 577.74 3 3
2 7 2003.12 44 14.08 3038 1882 2.02 / 579.63 3 3
3 13 1586.64 22 14.26 2471 775 2.80 / 580.40 2 3
4 13 884.44 22 14.53 1543 493 3.29 / 580.90 2 3
5 13 311.68 22 14.84 792 259 3.55 / 581.15 2 3
6 8 0.08 165 15.02 303 751 4.30 / 581.90 3 3
Average= 5.15
(KJ/cycle)

Cycle 125 GMT 16/ 2/2021 23:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.32 22 15.02 460 152 0.15 / 573.40 3 3
2 7 2003.08 44 14.08 3040 1883 2.04 / 575.28 3 3
3 13 1594.76 22 14.26 2490 781 2.82 / 576.07 2 3
4 13 1016.24 22 14.47 1720 548 3.36 / 576.61 2 3
5 13 288.08 22 14.86 748 245 3.61 / 576.86 2 3
6 8 0.08 165 15.02 301 746 4.35 / 577.60 3 3
Average= 5.16
(KJ/cycle)

Cycle 124 GMT 6/ 2/2021 23:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.92 22 15.01 456 151 0.15 / 568.95 3 3
2 7 2003.20 44 14.08 3049 1889 2.04 / 570.84 3 3
3 13 1871.36 22 14.15 2881 897 2.94 / 571.74 2 3
4 13 968.88 22 14.50 1647 525 3.46 / 572.26 2 3
5 13 271.64 22 14.88 722 236 3.70 / 572.50 2 3
6 8 0.04 165 15.02 302 748 4.45 / 573.25 3 3
Average= 5.16
(KJ/cycle)

Cycle 123 GMT 27/ 1/2021 23:10: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.20 22 15.01 458 151 0.15 / 564.53 3 3
2 7 2001.52 44 14.09 3031 1879 2.03 / 566.41 3 3
3 13 1590.80 22 14.26 2487 780 2.81 / 567.19 2 3
4 13 1018.24 22 14.47 1725 549 3.36 / 567.74 2 3
5 13 429.24 22 14.76 941 306 3.67 / 568.05 2 3
6 8 0.04 165 15.02 305 756 4.42 / 568.80 3 3
Average= 5.17
(KJ/cycle)

Cycle 122 GMT 17/ 1/2021 23: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.00 22 15.01 455 150 0.15 / 560.10 3 3
2 7 2003.72 44 14.09 3037 1883 2.03 / 561.99 3 3
3 13 1600.20 22 14.26 2493 782 2.82 / 562.77 2 3
4 13 1026.72 22 14.46 1743 554 3.37 / 563.32 2 3
5 13 416.64 22 14.76 923 300 3.67 / 563.62 2 3
6 8 0.12 165 15.02 306 758 4.43 / 564.38 3 3
Average= 5.18
(KJ/cycle)

Cycle 121 GMT 7/ 1/2021 22:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.96 21 15.02 454 143 0.14 / 555.71 3 3
2 3 1039.44 1 14.97 1880 28 0.17 / 555.74 2 3
3 7 2002.68 44 14.09 3036 1882 2.05 / 557.62 3 3
4 13 1596.28 22 14.26 2492 782 2.84 / 558.40 2 3
5 13 1011.84 22 14.46 1717 546 3.38 / 558.95 2 3
6 13 283.56 22 14.86 747 244 3.63 / 559.19 3 3
7 8 0.08 165 15.02 307 761 4.39 / 559.95 3 3
Average= 5.18
(KJ/cycle)

Cycle 120 GMT 28/12/2020 22:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.12 21 15.01 457 144 0.14 / 551.42 3 3
2 7 2001.68 44 14.13 2915 1812 1.96 / 553.23 3 3
3 13 1735.04 22 14.25 2541 797 2.75 / 554.03 2 3
4 13 1013.28 22 14.50 1637 522 3.28 / 554.55 2 3
5 13 327.20 22 14.84 805 263 3.54 / 554.82 2 3
6 8 0.04 165 15.03 303 751 4.29 / 555.57 3 3
Average= 5.19
(KJ/cycle)

Cycle 119 GMT 18/12/2020 22:15:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.44 21 15.01 471 148 0.15 / 547.13 3 3
2 7 2003.32 44 14.10 3023 1875 2.02 / 549.01 3 3
3 13 1468.96 22 14.31 2314 728 2.75 / 549.74 2 3
4 13 905.56 22 14.52 1578 504 3.26 / 550.24 2 3
5 13 332.88 22 14.82 822 268 3.52 / 550.51 2 3
6 8 0.08 165 15.01 310 768 4.29 / 551.28 3 3
Average= 5.20
(KJ/cycle)

Cycle 118 GMT 8/12/2020 21:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.80 21 15.01 446 141 0.14 / 542.76 3 3
2 7 2002.40 44 14.10 3037 1884 2.02 / 544.65 3 3
3 13 1601.52 22 14.26 2508 787 2.81 / 545.43 2 3
4 13 1010.88 22 14.48 1719 548 3.36 / 545.98 2 3
5 13 274.80 22 14.87 734 240 3.60 / 546.22 2 3
6 8 0.08 165 15.02 308 763 4.36 / 546.99 3 3
Average= 5.21
(KJ/cycle)

Cycle 117 GMT 28/11/2020 21:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.08 21 15.02 460 145 0.15 / 538.43 3 3
2 7 2002.36 44 14.09 3042 1886 2.03 / 540.31 3 3
3 13 1574.80 22 14.28 2464 774 2.81 / 541.09 2 3
4 13 989.48 22 14.49 1693 540 3.34 / 541.63 2 3
5 13 263.00 22 14.89 710 233 3.58 / 541.86 2 3
6 8 0.20 165 15.02 308 763 4.34 / 542.62 3 3
Average= 5.22
(KJ/cycle)

Cycle 116 GMT 18/11/2020 21:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.92 21 15.01 456 144 0.14 / 534.02 3 3
2 7 2001.68 44 14.10 3038 1885 2.03 / 535.91 3 3
3 13 1729.88 22 14.22 2682 839 2.87 / 536.75 2 3
4 13 982.16 22 14.50 1669 532 3.40 / 537.28 2 3
5 13 281.44 22 14.88 734 240 3.64 / 537.52 2 3
6 8 0.08 165 15.03 308 764 4.40 / 538.28 3 3
Average= 5.23
(KJ/cycle)

Cycle 115 GMT 8/11/2020 21:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.64 21 15.01 469 148 0.15 / 529.62 3 3
2 3 1015.72 1 15.09 1886 28 0.18 / 529.65 2 3
3 7 2006.76 44 14.10 3042 1887 2.06 / 531.53 3 3
4 13 1598.80 22 14.27 2499 785 2.85 / 532.32 2 3
5 13 872.12 22 14.55 1528 489 3.34 / 532.81 2 3
6 13 430.28 22 14.76 947 308 3.64 / 533.11 2 3
7 8 0.08 165 15.02 308 763 4.41 / 533.88 3 4
Average= 5.23
(KJ/cycle)

Cycle 114 GMT 29/10/2020 21:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.16 21 15.01 477 150 0.15 / 525.15 3 3
2 7 2001.92 44 14.09 3040 1885 2.04 / 527.03 3 3
3 13 1726.64 22 14.22 2672 836 2.87 / 527.87 2 3
4 13 998.68 22 14.49 1695 540 3.41 / 528.41 2 3
5 13 409.16 22 14.78 911 296 3.71 / 528.70 2 3
6 8 0.08 165 15.02 309 766 4.47 / 529.47 3 3
Average= 5.24
(KJ/cycle)

Cycle 113 GMT 19/10/2020 21:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.32 21 15.03 446 141 0.14 / 520.78 3 3
2 7 2008.28 44 14.09 3041 1885 2.03 / 522.66 3 3
3 13 1599.60 22 14.26 2521 791 2.82 / 523.45 2 3
4 13 899.12 22 14.53 1569 502 3.32 / 523.95 2 3
5 13 327.36 22 14.83 820 268 3.59 / 524.22 2 3
6 8 0.00 165 15.02 313 776 4.36 / 525.00 3 3
Average= 5.25
(KJ/cycle)

Cycle 112 GMT 9/10/2020 21:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.64 21 15.01 480 151 0.15 / 516.55 3 3
2 7 2002.76 44 14.14 2913 1812 1.96 / 518.36 3 3
3 13 1600.60 22 14.31 2371 746 2.71 / 519.11 2 3
4 13 909.60 22 14.58 1499 481 3.19 / 519.59 2 3
5 13 365.96 22 14.82 846 276 3.47 / 519.86 2 3
6 8 0.20 165 15.03 311 771 4.24 / 520.63 3 3
Average= 5.26
(KJ/cycle)

Cycle 111 GMT 29/ 9/2020 21: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.56 21 15.03 450 142 0.14 / 512.24 3 3
2 7 2002.12 44 14.14 2928 1822 1.96 / 514.06 3 3
3 13 1583.64 22 14.31 2373 747 2.71 / 514.80 2 3
4 13 1015.00 22 14.51 1630 520 3.23 / 515.32 2 3
5 13 440.60 22 14.78 918 298 3.53 / 515.62 2 3
6 8 0.12 165 15.03 312 774 4.30 / 516.40 3 4
Average= 5.27
(KJ/cycle)

Cycle 110 GMT 19/ 9/2020 21: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.48 21 15.02 470 148 0.15 / 507.87 3 3
2 7 2002.48 45 14.10 3046 1933 2.08 / 509.80 3 3
3 13 1574.36 22 14.28 2455 771 2.85 / 510.57 2 3
4 13 878.20 22 14.55 1543 494 3.35 / 511.06 2 3
5 13 296.88 22 14.86 773 253 3.60 / 511.32 3 3
6 8 0.12 165 15.03 313 776 4.38 / 512.09 3 3
Average= 5.28
(KJ/cycle)

Cycle 109 GMT 9/ 9/2020 20:51: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.32 21 15.02 458 144 0.14 / 503.57 3 3
2 7 2005.64 44 14.11 3034 1884 2.03 / 505.45 3 3
3 13 1576.48 22 14.28 2458 772 2.80 / 506.22 2 3
4 13 861.24 22 14.56 1500 480 3.28 / 506.70 2 3
5 13 291.36 22 14.87 764 250 3.53 / 506.95 2 3
6 8 0.12 165 15.03 308 764 4.29 / 507.72 3 4
Average= 5.29
(KJ/cycle)

Cycle 108 GMT 30/ 8/2020 20:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.80 21 15.01 465 147 0.15 / 499.28 3 3
2 7 2007.68 44 14.12 2992 1859 2.01 / 501.14 3 3
3 13 1485.48 22 14.34 2239 706 2.71 / 501.84 2 3
4 13 1067.48 22 14.48 1704 543 3.25 / 502.39 2 3
5 13 349.12 22 14.83 836 273 3.53 / 502.66 2 3
6 8 0.04 165 15.03 308 764 4.29 / 503.42 3 3
Average= 5.30
(KJ/cycle)

Cycle 107 GMT 20/ 8/2020 20:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.40 21 15.02 466 147 0.15 / 494.97 3 3
2 7 2002.92 44 14.10 3049 1892 2.04 / 496.86 3 3
3 13 1590.80 22 14.27 2483 780 2.82 / 497.64 2 3
4 13 865.76 22 14.56 1506 482 3.30 / 498.12 2 3
5 13 298.40 22 14.86 768 251 3.55 / 498.37 3 3
6 8 0.16 165 15.03 307 761 4.31 / 499.13 3 3
Average= 5.31
(KJ/cycle)

Cycle 106 GMT 10/ 8/2020 20:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.68 21 15.02 462 146 0.15 / 490.71 3 3
2 7 2005.96 44 14.12 3007 1868 2.01 / 492.58 3 3
3 13 1587.12 22 14.32 2372 747 2.76 / 493.33 2 3
4 13 881.48 22 14.58 1469 471 3.23 / 493.80 2 3
5 13 316.40 22 14.85 779 254 3.49 / 494.05 2 3
6 8 0.24 165 15.03 309 766 4.25 / 494.82 3 5
Average= 5.32
(KJ/cycle)

Cycle 105 GMT 31/ 7/2020 20: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.56 21 15.02 458 144 0.14 / 486.35 3 3
2 7 2005.96 44 14.11 3024 1877 2.02 / 488.23 3 3
3 13 1589.72 22 14.27 2475 777 2.80 / 489.01 2 3
4 13 1006.36 22 14.49 1697 541 3.34 / 489.55 2 3
5 13 284.80 22 14.88 750 246 3.59 / 489.79 2 3
6 8 0.12 165 15.03 312 774 4.36 / 490.57 3 3
Average= 5.33
(KJ/cycle)

Cycle 104 GMT 21/ 7/2020 20: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.00 21 15.02 449 142 0.14 / 482.00 3 3
2 7 2005.32 44 14.11 3026 1879 2.02 / 483.88 3 3
3 13 1605.56 22 14.27 2512 789 2.81 / 484.66 2 3
4 13 898.56 22 14.55 1556 498 3.31 / 485.16 2 3
5 13 324.92 22 14.84 816 266 3.57 / 485.43 2 3
6 8 0.12 165 15.02 314 778 4.35 / 486.21 3 4
Average= 5.34
(KJ/cycle)

Cycle 103 GMT 11/ 7/2020 19:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.40 21 15.02 470 148 0.15 / 477.67 3 3
2 7 2003.80 44 14.11 3035 1884 2.03 / 479.56 3 3
3 13 1590.72 22 14.28 2492 783 2.82 / 480.34 2 3
4 13 884.08 22 14.56 1517 486 3.30 / 480.83 2 3
5 13 312.88 22 14.85 794 259 3.56 / 481.09 3 3
6 8 0.04 165 15.03 310 769 4.33 / 481.86 3 4
Average= 5.35
(KJ/cycle)

Cycle 102 GMT 1/ 7/2020 19:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.76 21 15.03 462 146 0.15 / 473.34 3 3
2 7 2001.80 44 14.11 3036 1885 2.03 / 475.23 3 3
3 13 1590.84 22 14.28 2488 782 2.81 / 476.01 2 3
4 13 871.68 22 14.56 1521 487 3.30 / 476.50 2 3
5 13 295.68 22 14.86 772 252 3.55 / 476.75 2 3
6 8 0.12 165 15.03 313 776 4.33 / 477.53 3 3
Average= 5.37
(KJ/cycle)

Cycle 101 GMT 21/ 6/2020 19:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.16 21 15.03 451 142 0.14 / 469.00 3 3
2 7 2005.04 44 14.11 3047 1892 2.03 / 470.89 3 3
3 13 1595.28 22 14.28 2494 784 2.82 / 471.67 2 3
4 13 885.80 22 14.56 1553 497 3.32 / 472.17 2 3
5 13 304.04 22 14.86 784 256 3.57 / 472.43 3 3
6 8 -0.04 165 15.03 311 771 4.34 / 473.20 3 3
Average= 5.38
(KJ/cycle)

Cycle 100 GMT 11/ 6/2020 19: 9: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.40 21 15.03 446 141 0.14 / 464.71 3 3
2 7 2002.88 44 14.11 3033 1883 2.02 / 466.59 3 3
3 13 1565.80 22 14.29 2461 774 2.80 / 467.37 2 3
4 13 855.36 22 14.57 1495 479 3.28 / 467.85 2 3
5 13 283.84 22 14.88 744 244 3.52 / 468.09 3 3
6 8 0.12 165 15.04 309 767 4.29 / 468.86 3 3
Average= 5.39
(KJ/cycle)

Cycle 99 GMT 1/ 6/2020 19: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.28 21 15.03 451 142 0.14 / 460.45 3 3
2 7 2004.16 44 14.11 3026 1879 2.02 / 462.32 3 3
3 13 1457.68 22 14.34 2314 730 2.75 / 463.05 2 3
4 13 892.56 22 14.56 1530 490 3.24 / 463.54 2 3
5 13 307.84 22 14.86 790 258 3.50 / 463.80 2 3
6 8 0.12 165 15.03 309 766 4.27 / 464.57 3 4
Average= 5.40
(KJ/cycle)

Cycle 98 GMT 22/ 5/2020 18:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.08 21 15.04 456 144 0.14 / 456.00 3 3
2 7 2001.60 44 14.12 3023 1878 2.02 / 457.88 3 3
3 13 1578.00 22 14.30 2466 776 2.80 / 458.66 2 3
4 13 873.16 22 14.57 1513 485 3.28 / 459.14 2 3
5 13 431.80 22 14.77 945 307 3.59 / 459.45 2 3
6 13 25.04 22 15.06 336 111 3.70 / 459.56 3 3
7 8 0.04 165 15.03 299 742 4.44 / 460.30 3 7
Average= 5.42
(KJ/cycle)

Cycle 97 GMT 12/ 5/2020 18:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.28 20 15.04 466 140 0.14 / 451.62 3 3
2 3 1019.56 1 15.10 1864 28 0.17 / 451.65 2 3
3 7 2005.80 44 14.11 3041 1888 2.06 / 453.53 3 3
4 13 1596.32 22 14.29 2486 782 2.84 / 454.32 2 3
5 13 1018.56 22 14.49 1719 548 3.39 / 454.86 2 3
6 13 292.60 22 14.88 760 249 3.63 / 455.11 2 3
7 8 0.08 165 15.04 301 747 4.38 / 455.86 3 3
Average= 5.43
(KJ/cycle)

Cycle 96 GMT 2/ 5/2020 18:26: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.04 21 15.03 454 143 0.14 / 447.19 3 3
2 7 2006.04 44 14.13 2989 1858 2.00 / 449.04 3 3
3 13 1584.72 22 14.34 2346 740 2.74 / 449.78 2 3
4 13 1008.64 22 14.53 1627 520 3.26 / 450.31 2 3
5 13 433.92 22 14.79 924 301 3.56 / 450.61 2 3
6 13 30.04 22 15.06 350 116 3.68 / 450.72 3 3
7 8 0.00 165 15.04 305 757 4.44 / 451.48 3 4
Average= 5.44
(KJ/cycle)

Cycle 95 GMT 22/ 4/2020 18: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.72 21 15.03 462 146 0.15 / 442.83 3 3
2 7 2004.36 44 14.13 2993 1861 2.01 / 444.69 3 3
3 13 1592.32 22 14.33 2346 740 2.75 / 445.43 2 3
4 13 887.92 22 14.58 1480 475 3.22 / 445.91 2 3
5 13 323.84 22 14.86 785 257 3.48 / 446.16 2 3
6 13 40.44 22 15.05 367 122 3.60 / 446.28 3 3
7 8 0.12 165 15.03 306 759 4.36 / 447.04 3 3
Average= 5.45
(KJ/cycle)

Cycle 94 GMT 12/ 4/2020 17:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.72 21 15.04 470 148 0.15 / 438.35 3 3
2 7 2005.04 44 14.11 3045 1890 2.04 / 440.24 3 3
3 13 1595.16 22 14.29 2476 778 2.82 / 441.02 2 3
4 13 1003.40 22 14.50 1687 538 3.36 / 441.56 2 3
5 13 278.96 22 14.89 745 244 3.60 / 441.81 3 3
6 13 27.20 22 15.06 348 115 3.71 / 441.92 3 3
7 8 -0.08 165 15.04 308 764 4.48 / 442.69 3 4
Average= 5.47
(KJ/cycle)

Cycle 93 GMT 2/ 4/2020 17:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.12 20 15.05 445 134 0.13 / 434.04 3 3
2 7 1892.00 44 14.17 2872 1791 1.92 / 435.83 3 3
3 13 1761.76 22 14.23 2711 849 2.77 / 436.68 2 3
4 13 882.64 22 14.58 1528 490 3.26 / 437.17 2 3
5 13 315.04 22 14.86 805 263 3.53 / 437.43 2 3
6 8 0.08 165 15.04 311 772 4.30 / 438.21 3 3
Average= 5.48
(KJ/cycle)

Cycle 92 GMT 23/ 3/2020 16:20: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.68 21 15.03 453 143 0.14 / 429.64 3 3
2 7 2003.44 44 14.13 2991 1860 2.00 / 431.50 3 3
3 13 1598.44 22 14.33 2362 745 2.75 / 432.25 2 3
4 13 1028.64 22 14.51 1685 538 3.29 / 432.79 2 3
5 13 314.16 22 14.87 787 257 3.54 / 433.04 3 3
6 13 18.44 22 15.07 331 110 3.65 / 433.15 3 3
7 8 0.04 165 15.05 304 755 4.41 / 433.91 3 3
Average= 5.49
(KJ/cycle)

Cycle 91 GMT 13/ 3/2020 15:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.72 21 15.04 451 142 0.14 / 425.10 3 3
2 7 2003.96 44 14.11 3040 1887 2.03 / 426.99 3 3
3 13 1578.48 22 14.29 2465 775 2.80 / 427.77 2 3
4 13 990.48 22 14.51 1692 540 3.34 / 428.31 2 3
5 13 392.04 22 14.81 901 294 3.64 / 428.60 2 3
6 13 22.04 22 15.06 343 114 3.75 / 428.71 3 3
7 8 0.12 165 15.03 317 786 4.54 / 429.50 3 4
Average= 5.51
(KJ/cycle)

Cycle 90 GMT 3/ 3/2020 15:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.20 20 15.05 461 139 0.14 / 420.66 3 3
2 3 1017.00 1 15.11 1882 28 0.17 / 420.68 2 3
3 7 2002.80 44 14.12 3028 1881 2.05 / 422.57 3 3
4 13 1584.24 22 14.30 2472 778 2.83 / 423.34 2 3
5 13 861.52 22 14.58 1514 486 3.31 / 423.83 2 3
6 13 283.08 22 14.89 757 248 3.56 / 424.08 2 3
7 13 25.12 22 15.06 349 116 3.68 / 424.19 3 3
8 8 -0.04 165 15.04 310 769 4.44 / 424.96 3 4
Average= 5.52
(KJ/cycle)

Cycle 89 GMT 22/ 2/2020 15:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.16 21 15.05 451 143 0.14 / 416.32 3 3
2 7 2004.88 44 14.11 3049 1893 2.04 / 418.21 3 3
3 13 1598.56 22 14.29 2485 781 2.82 / 418.99 2 3
4 13 902.76 22 14.57 1559 500 3.32 / 419.49 2 3
5 13 325.36 22 14.86 821 268 3.58 / 419.76 2 3
6 8 0.12 165 15.05 306 760 4.34 / 420.52 3 3
Average= 5.53
(KJ/cycle)

Cycle 88 GMT 12/ 2/2020 15:11: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.96 21 15.05 454 143 0.14 / 412.05 3 3
2 7 2002.48 44 14.12 3027 1881 2.02 / 413.93 3 3
3 13 1460.68 22 14.35 2300 726 2.75 / 414.65 2 3
4 13 892.60 22 14.57 1554 498 3.25 / 415.15 2 3
5 13 313.76 22 14.87 796 260 3.51 / 415.41 2 3
6 8 0.00 165 15.05 307 762 4.27 / 416.17 3 3
Average= 5.55
(KJ/cycle)

Cycle 87 GMT 2/ 2/2020 14:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.08 21 15.04 452 143 0.14 / 407.74 3 3
2 7 2004.64 44 14.11 3026 1879 2.02 / 409.61 3 3
3 13 1595.64 22 14.30 2478 780 2.80 / 410.39 2 3
4 13 876.60 22 14.58 1529 490 3.29 / 410.88 2 3
5 13 302.76 22 14.88 787 258 3.55 / 411.14 2 3
6 8 0.16 165 15.05 306 760 4.31 / 411.90 3 3
Average= 5.57
(KJ/cycle)

Cycle 86 GMT 23/ 1/2020 14:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.08 21 15.04 458 145 0.14 / 403.31 3 3
2 7 2003.68 44 14.13 2985 1856 2.00 / 405.16 3 3
3 13 1466.04 22 14.35 2281 720 2.72 / 405.88 2 3
4 13 1043.56 22 14.51 1718 548 3.27 / 406.43 2 3
5 13 307.32 22 14.89 777 255 3.52 / 406.69 2 3
6 13 39.72 22 15.06 374 124 3.65 / 406.81 3 3
7 8 0.08 165 15.05 315 782 4.43 / 407.59 3 3
Average= 5.58
(KJ/cycle)

Cycle 85 GMT 13/ 1/2020 14:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.36 21 15.05 458 145 0.14 / 399.02 3 3
2 7 2002.88 44 14.12 3034 1885 2.03 / 400.91 3 3
3 13 1472.48 22 14.34 2329 735 2.76 / 401.64 2 3
4 13 906.64 22 14.57 1555 498 3.26 / 402.14 2 3
5 13 318.44 22 14.87 802 262 3.53 / 402.40 2 3
6 8 0.04 165 15.05 307 762 4.29 / 403.16 3 3
Average= 5.60
(KJ/cycle)

Cycle 84 GMT 3/ 1/2020 14:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.88 21 15.05 456 144 0.14 / 394.61 3 3
2 7 2004.04 44 14.11 3042 1889 2.03 / 396.50 3 3
3 13 1465.44 22 14.34 2330 735 2.77 / 397.24 2 3
4 13 1032.72 22 14.50 1751 559 3.33 / 397.80 2 3
5 13 427.80 22 14.80 953 310 3.64 / 398.11 2 3
6 8 0.04 165 15.05 310 770 4.41 / 398.88 3 3
Average= 5.62
(KJ/cycle)

Cycle 83 GMT 24/12/2019 14:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.76 21 15.05 447 141 0.14 / 390.31 3 3
2 7 2001.00 44 14.12 3028 1881 2.02 / 392.19 3 3
3 13 1585.72 22 14.31 2476 779 2.80 / 392.97 2 3
4 13 859.60 22 14.59 1503 482 3.28 / 393.46 2 3
5 13 293.52 22 14.89 766 251 3.54 / 393.71 2 3
6 8 0.00 165 15.06 307 763 4.30 / 394.47 3 5
Average= 5.64
(KJ/cycle)

Cycle 82 GMT 14/12/2019 14: 2: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.96 21 15.05 464 147 0.15 / 385.99 3 3
2 7 2004.64 44 14.11 3027 1879 2.03 / 387.87 3 3
3 13 1594.92 22 14.29 2513 790 2.82 / 388.66 2 3
4 13 871.32 22 14.59 1528 490 3.31 / 389.15 2 3
5 13 302.28 22 14.89 778 255 3.56 / 389.40 2 3
6 8 0.08 165 15.06 310 770 4.33 / 390.17 3 3
Average= 5.65
(KJ/cycle)

Cycle 81 GMT 4/12/2019 13:47:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.80 21 15.05 443 140 0.14 / 381.80 3 3
2 7 2004.84 44 14.12 3028 1881 2.02 / 383.68 3 3
3 13 1462.60 22 14.35 2314 731 2.75 / 384.41 2 3
4 13 780.56 22 14.63 1398 450 3.20 / 384.86 2 3
5 13 232.36 22 14.95 661 217 3.42 / 385.08 2 3
6 8 0.12 165 15.06 306 760 4.18 / 385.84 3 3
Average= 5.67
(KJ/cycle)

Cycle 80 GMT 24/11/2019 13: 6:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.04 21 15.06 452 143 0.14 / 377.44 3 3
2 7 2003.04 44 14.11 3048 1892 2.04 / 379.33 3 3
3 13 1598.40 22 14.30 2511 790 2.83 / 380.12 2 3
4 13 882.60 22 14.58 1545 496 3.32 / 380.62 2 3
5 13 319.60 22 14.87 812 266 3.59 / 380.88 2 3
6 8 0.04 165 15.05 313 777 4.36 / 381.66 3 3
Average= 5.70
(KJ/cycle)

Cycle 79 GMT 14/11/2019 12:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.52 20 15.06 462 139 0.14 / 373.09 3 3
2 3 1019.20 1 15.11 1880 28 0.17 / 373.12 2 3
3 7 2003.56 44 14.13 3025 1881 2.05 / 375.00 3 3
4 13 1459.16 22 14.36 2302 727 2.78 / 375.73 2 3
5 13 1027.52 22 14.51 1739 555 3.33 / 376.28 2 3
6 13 288.32 22 14.91 755 248 3.58 / 376.53 3 3
7 8 0.04 165 15.06 308 765 4.34 / 377.30 3 3
Average= 5.72
(KJ/cycle)

Cycle 78 GMT 4/11/2019 12:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 21 15.05 459 145 0.15 / 368.60 3 3
2 3 961.76 -1 15.47 0 0 0.00 / 368.60 3 3
3 3 1031.24 1 15.08 1881 28 0.17 / 368.63 2 3
4 7 2002.20 44 14.13 3038 1889 2.06 / 370.51 3 3
5 13 1594.68 22 14.30 2513 791 2.85 / 371.31 2 3
6 13 1133.60 22 14.46 1881 598 3.45 / 371.90 2 3
7 13 364.88 22 14.85 867 283 3.73 / 372.19 2 3
8 8 0.08 165 15.06 308 765 4.50 / 372.95 3 3
Average= 5.74
(KJ/cycle)

Cycle 77 GMT 25/10/2019 12:30:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.92 21 15.05 450 142 0.14 / 364.18 3 3
2 7 2004.36 44 14.13 3042 1891 2.03 / 366.07 3 3
3 13 1733.76 22 14.26 2697 846 2.88 / 366.91 2 3
4 13 982.08 22 14.54 1643 526 3.41 / 367.44 2 3
5 13 283.60 22 14.92 750 246 3.65 / 367.68 3 3
6 8 0.04 165 15.07 309 768 4.42 / 368.45 3 3
Average= 5.76
(KJ/cycle)

Cycle 76 GMT 15/10/2019 12:14: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.88 22 15.06 458 152 0.15 / 359.78 3 3
2 3 955.60 -1 15.47 0 0 0.00 / 359.78 3 3
3 3 1029.60 1 15.09 1838 28 0.18 / 359.81 2 3
4 7 2003.76 44 14.13 3032 1885 2.06 / 361.69 3 3
5 13 1731.76 22 14.25 2684 841 2.91 / 362.53 2 3
6 13 856.72 22 14.61 1484 477 3.38 / 363.01 2 3
7 13 291.88 22 14.91 757 248 3.63 / 363.26 2 3
8 8 0.08 165 15.06 311 773 4.40 / 364.03 3 3
Average= 5.78
(KJ/cycle)

Cycle 75 GMT 5/10/2019 12: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.88 21 15.07 459 145 0.15 / 355.48 3 3
2 3 1042.04 1 15.01 1848 28 0.17 / 355.51 2 3
3 7 2002.16 44 14.14 3028 1884 2.06 / 357.39 3 3
4 13 1342.80 22 14.42 2143 680 2.74 / 358.07 2 3
5 13 930.08 22 14.57 1587 509 3.25 / 358.58 2 3
6 13 331.68 22 14.88 821 269 3.51 / 358.85 2 3
7 8 0.04 165 15.06 314 780 4.29 / 359.63 3 3
Average= 5.80
(KJ/cycle)

Cycle 74 GMT 25/ 9/2019 11:38: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.20 21 15.05 467 148 0.15 / 351.12 3 3
2 7 2009.60 44 14.14 2998 1865 2.01 / 352.98 3 3
3 13 1596.80 22 14.36 2380 752 2.76 / 353.74 2 3
4 13 1007.96 22 14.56 1638 525 3.29 / 354.26 2 3
5 13 415.60 22 14.83 907 296 3.59 / 354.56 2 3
6 8 0.00 165 15.06 313 778 4.36 / 355.33 3 3
Average= 5.83
(KJ/cycle)

Cycle 73 GMT 15/ 9/2019 11:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.88 21 15.07 473 150 0.15 / 346.72 3 3
2 7 2004.80 44 14.14 3039 1891 2.04 / 348.61 3 3
3 13 1604.28 22 14.33 2494 786 2.83 / 349.40 2 3
4 13 1005.92 22 14.53 1715 548 3.37 / 349.95 2 3
5 13 281.12 22 14.93 747 245 3.62 / 350.19 3 3
6 8 0.08 165 15.07 314 781 4.40 / 350.97 3 3
Average= 5.85
(KJ/cycle)

Cycle 72 GMT 5/ 9/2019 11:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.16 21 15.07 449 142 0.14 / 342.33 3 3
2 7 2005.12 44 14.14 3037 1889 2.03 / 344.22 3 3
3 13 1730.68 22 14.27 2681 842 2.87 / 345.06 2 3
4 13 852.16 22 14.62 1495 481 3.35 / 345.54 2 3
5 13 287.60 22 14.92 754 247 3.60 / 345.79 3 3
6 8 0.20 165 15.07 314 781 4.38 / 346.57 3 3
Average= 5.87
(KJ/cycle)

Cycle 71 GMT 26/ 8/2019 10:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.88 21 15.06 461 146 0.15 / 337.97 3 3
2 7 2003.76 44 14.15 3024 1883 2.03 / 339.86 3 3
3 13 1475.04 22 14.37 2328 736 2.76 / 340.59 2 3
4 13 1036.36 22 14.52 1747 558 3.32 / 341.15 2 3
5 13 286.76 22 14.92 757 248 3.57 / 341.40 2 3
6 8 0.04 165 15.07 317 788 4.36 / 342.19 3 4
Average= 5.90
(KJ/cycle)

Cycle 70 GMT 16/ 8/2019 10:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.64 21 15.06 459 145 0.15 / 333.68 3 3
2 7 2005.04 44 14.15 3020 1880 2.03 / 335.56 3 3
3 13 1462.92 22 14.38 2312 731 2.76 / 336.29 2 3
4 13 905.88 22 14.60 1551 498 3.26 / 336.79 2 3
5 13 327.16 22 14.89 817 268 3.52 / 337.06 2 3
6 8 0.04 165 15.08 309 769 4.29 / 337.83 3 3
Average= 5.93
(KJ/cycle)

Cycle 69 GMT 6/ 8/2019 10:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.64 20 15.07 453 137 0.14 / 329.30 3 3
2 3 1024.20 1 15.14 1793 27 0.16 / 329.32 2 3
3 7 2005.04 44 14.19 2911 1818 1.98 / 331.14 3 3
4 13 1592.36 22 14.37 2364 747 2.73 / 331.89 2 3
5 13 1159.88 22 14.50 1823 582 3.31 / 332.47 2 3
6 13 408.24 22 14.85 905 296 3.61 / 332.77 2 3
7 8 0.08 165 15.08 310 771 4.38 / 333.54 3 3
Average= 5.96
(KJ/cycle)

Cycle 68 GMT 27/ 7/2019 10: 7: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.72 21 15.07 450 142 0.14 / 325.02 3 3
2 3 961.84 -1 15.47 0 0 0.00 / 325.02 3 3
3 3 1026.72 1 15.11 1877 28 0.17 / 325.05 2 3
4 7 2004.80 44 14.17 2993 1866 2.04 / 326.92 3 3
5 13 1584.96 22 14.37 2402 759 2.80 / 327.68 2 3
6 13 865.24 22 14.64 1478 476 3.27 / 328.15 2 3
7 13 307.52 22 14.92 771 253 3.53 / 328.41 2 3
8 8 0.16 165 15.09 303 754 4.28 / 329.16 3 3
Average= 5.98
(KJ/cycle)

Cycle 67 GMT 17/ 7/2019 9:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.84 21 15.07 462 146 0.15 / 320.66 3 3
2 3 1018.16 1 15.13 1884 29 0.17 / 320.69 2 3
3 7 2005.16 44 14.15 3050 1899 2.07 / 322.59 3 3
4 13 1592.60 22 14.34 2480 782 2.86 / 323.37 2 3
5 13 870.64 22 14.62 1523 490 3.35 / 323.86 2 3
6 13 293.64 22 14.92 765 251 3.60 / 324.11 2 3
7 8 0.08 165 15.08 309 769 4.37 / 324.88 3 4
Average= 6.02
(KJ/cycle)

Cycle 66 GMT 7/ 7/2019 9:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.76 21 15.08 463 147 0.15 / 316.25 3 3
2 7 2006.40 44 14.16 3028 1887 2.03 / 318.14 3 3
3 13 1592.16 22 14.34 2495 787 2.82 / 318.93 2 3
4 13 987.04 22 14.57 1662 533 3.35 / 319.46 2 3
5 13 380.00 22 14.87 876 287 3.64 / 319.75 2 3
6 8 0.00 165 15.09 308 767 4.41 / 320.51 3 3
Average= 6.05
(KJ/cycle)

Cycle 65 GMT 27/ 6/2019 9:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.24 22 15.08 461 153 0.15 / 311.87 3 3
2 7 2003.28 44 14.16 3033 1890 2.04 / 313.76 3 3
3 13 1729.52 22 14.29 2686 844 2.89 / 314.61 2 3
4 13 859.32 22 14.64 1497 482 3.37 / 315.09 2 3
5 13 295.36 22 14.93 768 252 3.62 / 315.34 2 3
6 8 0.12 165 15.09 308 767 4.39 / 316.11 3 3
Average= 6.08
(KJ/cycle)

Cycle 64 GMT 17/ 6/2019 9: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.16 21 15.08 444 141 0.14 / 307.51 3 3
2 3 1022.08 1 15.13 1869 28 0.17 / 307.54 2 3
3 7 2002.40 44 14.17 3021 1884 2.05 / 309.42 3 3
4 13 1585.36 22 14.35 2477 782 2.83 / 310.20 2 3
5 13 883.28 22 14.63 1538 495 3.33 / 310.70 2 3
6 13 300.32 22 14.93 775 255 3.58 / 310.95 2 3
7 8 0.08 165 15.09 309 769 4.35 / 311.72 3 3
Average= 6.11
(KJ/cycle)

Cycle 63 GMT 7/ 6/2019 8:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.52 21 15.08 468 148 0.15 / 303.15 3 3
2 7 2002.36 44 14.17 3033 1891 2.04 / 305.04 3 3
3 13 1575.48 22 14.37 2454 776 2.82 / 305.82 2 3
4 13 995.00 22 14.57 1703 546 3.36 / 306.36 2 3
5 13 266.48 22 14.96 721 237 3.60 / 306.60 3 3
6 8 0.04 165 15.09 308 767 4.37 / 307.37 3 4
Average= 6.15
(KJ/cycle)

Cycle 62 GMT 28/ 5/2019 8:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.04 21 15.10 457 145 0.14 / 298.67 3 3
2 7 2003.56 44 14.17 3027 1887 2.03 / 300.56 3 3
3 13 1739.76 22 14.30 2690 846 2.88 / 301.41 2 3
4 13 969.48 22 14.60 1644 528 3.41 / 301.93 2 3
5 13 382.48 22 14.88 886 290 3.70 / 302.22 2 3
6 8 0.12 165 15.09 312 777 4.47 / 303.00 3 3
Average= 6.18
(KJ/cycle)

Cycle 61 GMT 18/ 5/2019 8: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.28 21 15.10 466 148 0.15 / 294.31 3 3
2 7 2003.04 44 14.18 3036 1894 2.04 / 296.21 3 3
3 13 1579.56 22 14.37 2464 779 2.82 / 296.99 2 3
4 13 1002.64 22 14.59 1682 540 3.36 / 297.53 2 3
5 13 273.16 22 14.96 734 242 3.60 / 297.77 3 3
6 8 -0.04 165 15.11 305 760 4.36 / 298.53 3 3
Average= 6.22
(KJ/cycle)

Cycle 60 GMT 8/ 5/2019 7:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.56 21 15.10 459 146 0.15 / 289.99 3 3
2 7 2004.52 44 14.19 3016 1883 2.03 / 291.88 3 3
3 13 1592.76 22 14.37 2475 782 2.81 / 292.66 2 3
4 13 868.16 22 14.65 1501 484 3.29 / 293.14 2 3
5 13 294.24 22 14.94 771 253 3.55 / 293.40 2 3
6 8 0.08 165 15.10 309 770 4.32 / 294.16 3 3
Average= 6.26
(KJ/cycle)

Cycle 59 GMT 28/ 4/2019 7:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.88 21 15.10 467 148 0.15 / 285.67 3 3
2 7 2005.76 44 14.18 3031 1891 2.04 / 287.56 3 3
3 13 1585.40 22 14.37 2476 783 2.82 / 288.34 2 3
4 13 884.04 22 14.64 1540 496 3.32 / 288.84 2 3
5 13 293.60 22 14.94 762 250 3.57 / 289.09 2 3
6 8 0.12 165 15.11 305 760 4.33 / 289.85 3 3
Average= 6.30
(KJ/cycle)

Cycle 58 GMT 18/ 4/2019 6:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.64 21 15.10 457 145 0.14 / 281.26 3 3
2 7 2003.44 44 14.19 3014 1882 2.03 / 283.14 3 3
3 13 1587.72 22 14.38 2465 780 2.81 / 283.92 2 3
4 13 999.88 22 14.59 1688 542 3.35 / 284.47 2 3
5 13 390.84 22 14.88 889 291 3.64 / 284.76 2 3
6 8 -0.04 165 15.11 305 760 4.40 / 285.52 3 3
Average= 6.34
(KJ/cycle)

Cycle 57 GMT 8/ 4/2019 6:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.80 21 15.10 454 144 0.14 / 277.02 3 3
2 7 2002.80 44 14.19 3025 1889 2.03 / 278.91 3 3
3 13 1457.72 22 14.43 2283 725 2.76 / 279.63 2 3
4 13 788.68 22 14.70 1408 455 3.21 / 280.09 2 3
5 13 347.64 22 14.91 835 274 3.49 / 280.36 2 3
6 8 0.16 165 15.11 304 758 4.24 / 281.12 3 4
Average= 6.39
(KJ/cycle)

Cycle 56 GMT 29/ 3/2019 6: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.88 21 15.11 447 142 0.14 / 272.72 3 3
2 7 2016.72 44 14.19 3040 1898 2.04 / 274.61 3 3
3 13 1600.96 22 14.38 2482 785 2.83 / 275.40 2 3
4 13 769.80 22 14.71 1383 448 3.27 / 275.85 2 3
5 13 335.68 22 14.92 825 271 3.54 / 276.12 2 3
6 8 0.08 165 15.11 303 755 4.30 / 276.87 3 3
Average= 6.44
(KJ/cycle)

Cycle 55 GMT 19/ 3/2019 5:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.44 21 15.11 465 148 0.15 / 268.39 3 3
2 7 2004.56 44 14.20 3032 1894 2.04 / 270.28 3 3
3 13 1466.48 22 14.43 2296 729 2.77 / 271.01 2 3
4 13 1027.76 22 14.58 1727 554 3.32 / 271.57 2 3
5 13 281.00 22 14.97 750 247 3.57 / 271.81 2 3
6 8 0.12 165 15.12 305 761 4.33 / 272.57 3 4
Average= 6.49
(KJ/cycle)

Cycle 54 GMT 9/ 3/2019 5: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.28 21 15.11 455 144 0.14 / 264.07 3 3
2 7 2001.80 44 14.20 3012 1882 2.03 / 265.95 3 3
3 13 1595.88 22 14.39 2484 786 2.81 / 266.73 2 3
4 13 874.56 22 14.66 1528 493 3.31 / 267.23 2 3
5 13 295.12 22 14.96 770 253 3.56 / 267.48 3 3
6 8 0.12 165 15.12 305 761 4.32 / 268.24 3 3
Average= 6.54
(KJ/cycle)

Cycle 53 GMT 27/ 2/2019 4:25: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.44 21 15.12 467 148 0.15 / 259.76 3 3
2 7 2003.28 44 14.20 3027 1891 2.04 / 261.65 3 3
3 13 1465.48 22 14.44 2306 733 2.77 / 262.38 2 3
4 13 906.28 22 14.65 1560 503 3.27 / 262.88 2 3
5 13 325.88 22 14.93 821 270 3.54 / 263.15 2 3
6 8 0.00 165 15.12 308 768 4.31 / 263.92 3 4
Average= 6.60
(KJ/cycle)

Cycle 52 GMT 17/ 2/2019 3:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.84 21 15.11 444 141 0.14 / 255.34 3 3
2 7 2006.16 44 14.20 3034 1896 2.04 / 257.24 3 3
3 13 1735.16 22 14.33 2680 845 2.88 / 258.08 2 3
4 13 977.00 22 14.63 1648 530 3.41 / 258.61 2 3
5 13 257.76 22 15.00 707 233 3.65 / 258.85 2 3
6 8 0.20 165 15.13 305 761 4.41 / 259.61 3 3
Average= 6.66
(KJ/cycle)

Cycle 51 GMT 7/ 2/2019 3:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.92 21 15.12 454 144 0.14 / 251.09 3 3
2 7 2004.04 44 14.21 3015 1885 2.03 / 252.98 3 3
3 13 1462.24 22 14.45 2304 732 2.76 / 253.71 2 3
4 13 779.00 22 14.72 1400 453 3.22 / 254.16 2 3
5 13 342.04 22 14.93 831 273 3.49 / 254.43 2 3
6 8 0.04 165 15.12 308 768 4.26 / 255.20 3 3
Average= 6.72
(KJ/cycle)

Cycle 50 GMT 28/ 1/2019 2:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.88 21 15.11 451 143 0.14 / 246.82 3 3
2 7 2002.72 44 14.22 3026 1893 2.04 / 248.71 3 3
3 13 1447.68 22 14.45 2283 726 2.76 / 249.43 2 3
4 13 877.40 22 14.67 1532 494 3.26 / 249.93 2 3
5 13 295.12 22 14.97 770 254 3.51 / 250.18 3 3
6 8 0.16 165 15.13 306 764 4.27 / 250.95 3 3
Average= 6.78
(KJ/cycle)

Cycle 49 GMT 18/ 1/2019 2:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.76 21 15.12 455 144 0.14 / 242.52 3 3
2 7 2004.48 44 14.22 3023 1891 2.04 / 244.41 3 3
3 13 1462.60 22 14.45 2305 733 2.77 / 245.14 2 3
4 13 892.92 22 14.67 1552 501 3.27 / 245.64 2 3
5 13 309.00 22 14.96 789 260 3.53 / 245.90 2 3
6 8 0.04 165 15.13 308 769 4.30 / 246.67 3 3
Average= 6.85
(KJ/cycle)

Cycle 48 GMT 8/ 1/2019 2: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.00 21 15.12 450 143 0.14 / 238.37 3 3
2 7 2002.08 44 14.22 3017 1888 2.03 / 240.26 3 3
3 13 1325.60 22 14.51 2112 674 2.70 / 240.93 2 3
4 13 781.88 22 14.72 1402 454 3.16 / 241.39 2 3
5 13 216.08 22 15.04 647 214 3.37 / 241.60 2 3
6 8 0.12 165 15.13 309 771 4.14 / 242.37 3 4
Average= 6.92
(KJ/cycle)

Cycle 47 GMT 29/12/2018 1:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.36 21 15.12 457 145 0.15 / 234.09 3 3
2 7 2003.72 44 14.22 3027 1894 2.04 / 235.98 3 3
3 13 1456.04 22 14.46 2299 731 2.77 / 236.71 2 3
4 13 882.64 22 14.69 1522 492 3.26 / 237.21 2 2
5 13 293.76 22 14.98 761 251 3.51 / 237.46 2 3
6 8 0.04 165 15.13 310 774 4.29 / 238.23 3 3
Average= 7.01
(KJ/cycle)

Cycle 46 GMT 19/12/2018 1: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.96 21 15.13 446 142 0.14 / 229.72 3 3
2 7 2002.44 44 14.22 3034 1898 2.04 / 231.62 3 3
3 13 1463.48 22 14.46 2312 735 2.78 / 232.35 2 3
4 13 1029.08 22 14.61 1726 555 3.33 / 232.91 2 3
5 13 288.76 22 14.99 765 252 3.58 / 233.16 2 3
6 8 0.08 165 15.14 313 782 4.36 / 233.94 3 3
Average= 7.09
(KJ/cycle)

Cycle 45 GMT 9/12/2018 0:51: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.12 21 15.13 453 144 0.14 / 225.39 3 3
2 7 2003.44 44 14.24 3028 1897 2.04 / 227.28 3 3
3 13 1575.56 22 14.41 2472 784 2.82 / 228.07 2 3
4 13 863.52 22 14.70 1508 488 3.31 / 228.56 2 3
5 13 279.36 22 14.99 745 246 3.56 / 228.80 2 3
6 8 0.04 165 15.14 311 777 4.34 / 229.58 3 3
Average= 7.17
(KJ/cycle)

Cycle 44 GMT 29/11/2018 0:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.20 20 15.13 467 141 0.14 / 221.03 3 3
2 3 1036.52 1 15.01 1853 28 0.17 / 221.06 2 3
3 7 2002.88 44 14.23 3023 1893 2.06 / 222.95 3 3
4 13 1588.24 22 14.41 2476 785 2.85 / 223.74 2 3
5 13 852.84 22 14.70 1509 488 3.33 / 224.23 2 3
6 13 277.08 22 15.00 748 247 3.58 / 224.47 2 3
7 8 0.04 165 15.14 308 769 4.35 / 225.24 3 3
Average= 7.27
(KJ/cycle)

Cycle 43 GMT 18/11/2018 23:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.32 21 15.13 448 142 0.14 / 216.66 3 3
2 3 965.60 -1 15.50 0 0 0.00 / 216.66 3 3
3 3 1027.80 1 15.09 1850 28 0.17 / 216.69 2 3
4 7 2002.16 44 14.26 2959 1857 2.03 / 218.55 3 3
5 13 1581.32 22 14.45 2400 763 2.79 / 219.31 2 3
6 13 983.08 22 14.66 1621 523 3.31 / 219.83 2 3
7 13 388.12 22 14.94 877 288 3.60 / 220.12 2 3
8 8 0.04 165 15.15 308 770 4.37 / 220.89 3 3
Average= 7.36
(KJ/cycle)

Cycle 42 GMT 8/11/2018 23:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.48 21 15.13 460 146 0.15 / 212.37 3 3
2 7 2003.16 44 14.27 2957 1857 2.00 / 214.23 3 3
3 13 1605.36 22 14.43 2436 773 2.78 / 215.00 2 3
4 13 885.80 22 14.70 1516 490 3.27 / 215.49 2 3
5 13 314.84 22 14.99 775 256 3.52 / 215.75 2 3
6 8 0.12 165 15.15 309 772 4.29 / 216.52 3 4
Average= 7.47
(KJ/cycle)

Cycle 41 GMT 29/10/2018 22:42:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.08 21 15.14 452 144 0.14 / 208.11 3 3
2 7 2005.12 44 14.27 2948 1851 1.99 / 209.96 3 3
3 13 1471.12 22 14.48 2269 723 2.72 / 210.68 2 3
4 13 925.28 22 14.69 1556 503 3.22 / 211.18 2 3
5 13 342.00 22 14.97 813 268 3.49 / 211.45 2 3
6 8 0.08 165 15.15 310 775 4.26 / 212.23 3 3
Average= 7.58
(KJ/cycle)

Cycle 40 GMT 19/10/2018 21:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.24 20 15.14 457 138 0.14 / 203.80 3 3
2 3 1013.08 1 15.18 1868 28 0.17 / 203.82 2 3
3 7 2003.00 44 14.27 2974 1867 2.03 / 205.69 3 3
4 13 1460.24 22 14.49 2245 716 2.75 / 206.41 2 3
5 13 1028.96 22 14.65 1674 540 3.29 / 206.95 2 3
6 13 294.32 22 15.01 753 249 3.54 / 207.20 2 3
7 8 0.08 165 15.16 307 768 4.31 / 207.96 3 3
Average= 7.70
(KJ/cycle)

Cycle 39 GMT 9/10/2018 21: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.44 20 15.14 468 142 0.14 / 199.42 3 3
2 3 1013.64 1 15.17 1852 28 0.17 / 199.45 2 3
3 7 2003.84 44 14.26 3028 1900 2.07 / 201.35 3 3
4 13 1591.48 22 14.43 2456 780 2.85 / 202.13 2 3
5 13 873.60 22 14.71 1532 496 3.35 / 202.63 2 3
6 13 292.32 22 15.00 772 255 3.60 / 202.88 3 3
7 8 0.12 165 15.16 310 775 4.38 / 203.66 3 3
Average= 7.83
(KJ/cycle)

Cycle 38 GMT 29/ 9/2018 20:42: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.64 21 15.14 456 145 0.14 / 195.11 3 3
2 7 2004.00 44 14.28 2961 1860 2.01 / 196.97 3 3
3 13 1594.48 22 14.45 2448 778 2.78 / 197.75 2 3
4 13 996.48 22 14.66 1648 532 3.32 / 198.28 2 3
5 13 276.00 22 15.04 720 238 3.55 / 198.52 3 3
6 8 0.08 165 15.16 306 765 4.32 / 199.28 3 3
Average= 7.97
(KJ/cycle)

Cycle 37 GMT 19/ 9/2018 20: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.96 20 15.15 465 141 0.14 / 190.79 3 3
2 7 2002.92 44 14.28 2979 1872 2.01 / 192.66 3 3
3 13 1465.84 22 14.50 2276 726 2.74 / 193.38 2 3
4 13 1044.32 22 14.65 1707 550 3.29 / 193.93 2 3
5 13 311.56 22 15.00 791 261 3.55 / 194.20 2 3
6 8 0.00 165 15.16 307 768 4.32 / 194.96 3 3
Average= 8.12
(KJ/cycle)

Cycle 36 GMT 9/ 9/2018 19:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.40 19 15.15 459 132 0.13 / 186.16 3 3
2 3 1026.92 1 15.09 1831 28 0.16 / 186.19 2 3
3 7 2002.80 66 14.23 2939 2760 2.92 / 188.95 3 3
4 13 893.72 33 14.69 1508 731 3.65 / 189.68 2 3
5 13 62.84 33 15.17 397 199 3.85 / 189.88 3 3
6 8 -0.04 165 15.16 308 770 4.62 / 190.65 3 4
Average= 8.29
(KJ/cycle)

Cycle 35 GMT 30/ 8/2018 19:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.52 16 15.15 455 110 0.11 / 181.34 3 3
2 10 1016.04 6 14.86 1751 156 0.27 / 181.49 3 3
3 3 965.08 -1 15.51 0 0 0.16 / 181.49 3 3
4 3 1013.04 1 15.20 1816 28 0.29 / 181.52 2 3
5 7 2001.84 66 14.24 2929 2753 3.05 / 184.27 3 3
6 13 934.04 33 14.68 1569 760 3.81 / 185.03 2 3
7 13 91.12 33 15.15 443 221 4.03 / 185.26 3 3
8 8 0.12 165 15.16 308 770 4.80 / 186.03 3 3
Average= 8.46
(KJ/cycle)

Cycle 34 GMT 20/ 8/2018 19: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.56 31 15.14 466 219 0.22 / 176.68 3 3
2 3 603.24 -8 15.52 0 0 0.00 / 176.68 3 3
3 3 904.96 -2 15.54 0 0 0.00 / 176.68 3 3
4 7 2004.52 66 14.22 2983 2800 3.02 / 179.48 3 3
5 13 929.64 33 14.67 1554 752 3.77 / 180.23 2 3
6 13 78.44 33 15.16 423 212 3.98 / 180.45 3 3
7 8 0.00 165 15.16 312 780 4.76 / 181.23 3 3
Average= 8.63
(KJ/cycle)

Cycle 33 GMT 10/ 8/2018 18:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.52 31 15.15 426 200 0.20 / 171.88 3 3
2 7 2006.40 66 14.45 2316 2209 2.41 / 174.08 3 3
3 13 1438.40 33 14.49 2129 1018 3.43 / 175.10 2 3
4 13 645.64 33 14.81 1185 579 4.01 / 175.68 2 3
5 8 0.08 165 15.16 313 783 4.79 / 176.46 3 3
Average= 8.82
(KJ/cycle)

Cycle 32 GMT 31/ 7/2018 18:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.40 32 15.14 423 205 0.20 / 167.28 3 3
2 7 2002.24 66 14.54 2148 2061 2.27 / 169.34 3 3
3 13 1437.36 33 14.66 1692 819 3.08 / 170.16 2 3
4 13 726.04 33 14.90 1007 495 3.58 / 170.66 2 3
5 13 157.08 33 15.13 483 241 3.82 / 170.90 3 3
6 8 0.08 165 15.16 311 778 4.60 / 171.68 3 3
Average= 9.04
(KJ/cycle)

Cycle 31 GMT 21/ 7/2018 17:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.00 32 15.15 418 203 0.20 / 162.47 3 3
2 3 970.40 -1 15.52 0 0 0.00 / 162.47 3 3
3 3 1032.48 1 15.19 1444 22 0.22 / 162.49 2 3
4 7 2000.80 66 14.51 2210 2116 2.34 / 164.61 3 3
5 13 1435.72 33 14.65 1731 837 3.18 / 165.45 2 3
6 13 841.56 33 14.84 1126 551 3.73 / 166.00 2 3
7 13 244.24 33 15.07 593 295 4.02 / 166.29 2 3
8 8 0.00 165 15.16 313 783 4.81 / 167.08 3 3
Average= 9.28
(KJ/cycle)

Cycle 30 GMT 11/ 7/2018 16:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.00 32 15.16 417 202 0.20 / 157.93 3 3
2 7 2000.96 66 14.53 2185 2095 2.30 / 160.03 3 3
3 13 1304.16 33 14.69 1577 764 3.06 / 160.79 2 3
4 13 620.28 33 14.90 966 475 3.54 / 161.27 2 3
5 13 98.64 33 15.16 426 213 3.75 / 161.48 3 3
6 8 0.00 165 15.16 315 788 4.54 / 162.27 3 3
Average= 9.55
(KJ/cycle)

Cycle 29 GMT 1/ 7/2018 16: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.44 33 15.16 421 211 0.21 / 153.17 3 3
2 3 950.20 -1 15.53 0 0 0.00 / 153.17 3 3
3 3 1013.36 1 15.26 1422 22 0.23 / 153.19 2 3
4 7 2002.72 67 14.52 2195 2135 2.37 / 155.33 3 3
5 13 1552.60 33 14.62 1828 882 3.25 / 156.21 2 3
6 13 698.24 33 14.88 1035 508 3.76 / 156.72 2 3
7 13 133.96 33 15.15 460 230 3.99 / 156.95 3 3
8 8 0.00 165 15.17 312 781 4.77 / 157.73 3 3
Average= 9.86
(KJ/cycle)

Cycle 28 GMT 21/ 6/2018 15:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.44 37 15.17 401 225 0.23 / 148.55 3 3
2 3 904.76 -2 15.53 0 0 0.00 / 148.55 3 3
3 7 2002.56 66 14.52 2198 2106 2.33 / 150.66 3 3
4 13 1429.60 33 14.66 1691 818 3.15 / 151.48 2 3
5 13 714.68 33 14.89 1029 506 3.66 / 151.98 2 3
6 13 79.20 33 15.18 398 199 3.85 / 152.18 3 3
7 8 0.16 165 15.18 311 779 4.63 / 152.96 3 3
Average= 10.20
(KJ/cycle)

Cycle 27 GMT 11/ 6/2018 14:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.48 63 15.16 402 384 0.38 / 143.83 3 3
2 3 292.12 -13 15.57 0 0 0.00 / 143.83 3 3
3 3 768.80 -4 15.58 0 0 0.00 / 143.83 3 3
4 7 2002.08 66 14.50 2219 2124 2.51 / 145.95 3 3
5 13 1443.24 33 14.64 1757 849 3.36 / 146.80 2 3
6 13 714.76 33 14.87 1062 521 3.88 / 147.32 2 3
7 13 136.72 33 15.15 461 230 4.11 / 147.55 3 3
8 8 0.00 165 15.17 311 778 4.89 / 148.33 3 3
Average= 10.59
(KJ/cycle)

Cycle 26 GMT 1/ 6/2018 14:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.52 52 15.19 357 282 0.28 / 138.78 3 3
2 10 1012.92 5 15.12 1169 88 0.37 / 138.87 3 3
3 10 1048.64 3 15.01 1447 65 0.44 / 138.93 3 3
4 3 1080.20 2 15.07 1506 45 0.48 / 138.98 2 3
5 3 1041.36 1 15.22 1371 21 0.50 / 139.00 2 3
6 7 2000.60 66 14.53 2204 2114 2.62 / 141.11 3 3
7 13 1439.64 33 14.65 1730 836 3.45 / 141.95 2 3
8 13 730.24 33 14.93 979 482 3.93 / 142.43 2 3
9 13 154.60 33 15.15 476 238 4.17 / 142.67 3 3
10 8 0.08 165 15.18 309 774 4.95 / 143.44 3 3
Average= 11.03
(KJ/cycle)

Cycle 25 GMT 22/ 5/2018 14:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.72 70 15.16 426 452 0.45 / 134.22 3 3
2 7 1914.92 67 14.54 2154 2098 2.55 / 136.32 3 3
3 13 1345.60 33 14.71 1613 783 3.33 / 137.10 2 3
4 13 630.00 33 14.96 929 459 3.79 / 137.56 2 3
5 13 107.24 33 15.20 374 188 3.98 / 137.75 3 3
6 8 0.08 165 15.21 298 748 4.73 / 138.50 3 3
Average= 11.54
(KJ/cycle)

Cycle 24 GMT 12/ 5/2018 12:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.96 67 15.18 364 370 0.37 / 129.45 3 3
2 10 1054.92 3 15.17 1244 57 0.43 / 129.50 2 3
3 3 1044.28 1 15.19 1401 21 0.45 / 129.53 2 3
4 7 2006.48 44 14.60 2203 1415 1.86 / 130.94 2 3
5 13 1893.12 22 14.61 2174 699 2.56 / 131.64 2 2
6 13 1339.16 22 14.74 1622 526 3.09 / 132.17 2 3
7 13 931.12 22 14.85 1243 406 3.49 / 132.57 2 3
8 13 518.88 22 15.00 844 279 3.77 / 132.85 2 3
9 13 118.88 22 15.18 445 149 3.92 / 133.00 3 3
10 8 0.04 165 15.19 307 769 4.69 / 133.77 3 3
Average= 12.16
(KJ/cycle)

Cycle 23 GMT 2/ 5/2018 11:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.68 61 15.20 338 313 0.31 / 124.58 3 3
2 10 1077.68 3 15.09 1275 58 0.37 / 124.64 3 3
3 3 1080.40 2 15.10 1419 43 0.41 / 124.69 2 3
4 3 1043.80 1 15.18 1447 22 0.44 / 124.71 2 3
5 7 2006.76 44 14.60 2199 1413 1.85 / 126.12 3 3
6 13 1892.64 22 14.60 2189 703 2.55 / 126.82 2 3
7 13 1472.40 22 14.73 1715 556 3.11 / 127.38 2 3
8 13 1045.56 22 14.81 1346 439 3.55 / 127.82 2 3
9 13 504.04 22 14.98 871 287 3.83 / 128.10 2 3
10 13 221.12 22 15.11 591 196 4.03 / 128.30 3 3
11 8 0.08 165 15.19 310 777 4.81 / 129.08 3 3
Average= 12.91
(KJ/cycle)

Cycle 22 GMT 22/ 4/2018 10:41: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.88 22 15.21 358 120 0.12 / 119.15 3 3
2 10 1026.96 7 15.22 790 84 0.20 / 119.23 3 3
3 10 1086.84 6 15.06 1055 95 0.30 / 119.33 3 3
4 10 1145.40 6 15.19 853 78 0.38 / 119.41 3 3
5 10 1207.44 6 15.06 1133 102 0.48 / 119.51 3 3
6 10 1247.72 4 15.19 892 54 0.53 / 119.56 2 3
7 3 1349.72 9 15.01 1562 211 0.74 / 119.77 2 3
8 3 1233.80 6 15.06 1329 120 0.86 / 119.89 2 3
9 7 2002.48 44 14.63 2188 1408 2.27 / 121.30 3 3
10 13 1883.12 22 14.65 2121 684 2.96 / 121.99 2 3
11 13 1471.52 22 14.79 1587 516 3.47 / 122.50 2 3
12 13 1050.84 22 14.83 1315 429 3.90 / 122.93 2 3
13 13 616.36 22 14.96 932 307 4.21 / 123.24 2 3
14 13 208.92 22 15.16 468 156 4.37 / 123.39 3 3
15 13 58.00 22 15.22 346 116 4.48 / 123.51 3 3
16 8 0.04 165 15.20 304 762 5.24 / 124.27 3 3
Average= 13.81
(KJ/cycle)

Cycle 21 GMT 12/ 4/2018 10:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.44 22 15.20 461 154 0.15 / 114.77 3 3
2 7 2002.08 44 14.58 2233 1433 1.59 / 116.20 3 3
3 13 1743.16 22 14.70 1944 629 2.22 / 116.83 2 3
4 13 1346.56 22 14.78 1594 518 2.73 / 117.35 2 3
5 13 940.72 22 14.86 1220 399 3.13 / 117.75 2 3
6 13 520.80 22 15.00 841 278 3.41 / 118.03 2 3
7 13 137.48 22 15.20 409 137 3.55 / 118.16 3 3
8 13 37.32 22 15.22 333 112 3.66 / 118.27 3 3
9 8 0.08 165 15.20 301 755 4.41 / 119.03 3 3
Average= 14.88
(KJ/cycle)

Cycle 20 GMT 2/ 4/2018 9:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.52 22 15.19 481 161 0.16 / 110.39 3 3
2 7 2001.52 44 14.35 2994 1890 2.05 / 112.28 3 3
3 13 1717.04 22 14.47 2615 832 2.88 / 113.11 2 3
4 13 843.32 22 14.80 1454 473 3.36 / 113.59 2 3
5 13 261.08 22 15.09 716 238 3.59 / 113.82 3 3
6 8 0.00 165 15.21 315 791 4.39 / 114.62 3 4
Average= 16.37
(KJ/cycle)

Cycle 19 GMT 23/ 3/2018 8:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.40 23 15.19 472 165 0.16 / 106.04 3 3
2 7 2001.52 44 14.36 2992 1890 2.06 / 107.93 3 3
3 13 1571.40 22 14.53 2439 780 2.84 / 108.71 2 3
4 13 847.20 22 14.80 1462 476 3.31 / 109.19 2 3
5 13 278.80 22 15.08 736 244 3.56 / 109.43 2 3
6 8 0.20 165 15.21 318 798 4.35 / 110.23 3 3
Average= 18.37
(KJ/cycle)

Cycle 18 GMT 13/ 3/2018 7:20: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.60 23 15.21 465 163 0.16 / 101.74 3 3
2 7 2000.88 44 14.37 2966 1875 2.04 / 103.62 3 3
3 13 1443.12 22 14.59 2222 713 2.75 / 104.33 2 3
4 13 884.52 22 14.78 1506 490 3.24 / 104.82 2 3
5 13 297.60 22 15.07 755 250 3.49 / 105.07 2 3
6 8 0.12 165 15.21 320 803 4.29 / 105.88 3 4
Average= 21.18
(KJ/cycle)

Cycle 17 GMT 3/ 3/2018 6:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.92 4 15.23 478 29 0.03 / 97.86 3 3
2 7 1759.28 44 14.49 2654 1692 1.72 / 99.55 3 3
3 13 1319.92 22 14.66 2082 671 2.39 / 100.22 2 3
4 13 712.16 22 14.88 1286 421 2.81 / 100.65 2 3
5 13 63.48 22 15.24 417 140 2.95 / 100.79 3 3
6 8 0.12 165 15.23 317 797 3.75 / 101.58 3 3
Average= 25.40
(KJ/cycle)

Cycle 16 GMT 21/ 2/2018 11:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.40 4 15.24 472 29 0.03 / 94.13 3 3
2 7 1764.68 44 14.50 2653 1693 1.72 / 95.82 3 3
3 13 1347.48 22 14.66 2101 678 2.40 / 96.50 2 3
4 13 612.60 22 14.93 1164 382 2.78 / 96.88 2 3
5 13 89.56 22 15.22 448 150 2.93 / 97.03 3 3
6 8 0.00 165 15.23 318 799 3.73 / 97.83 3 3
Average= 32.61
(KJ/cycle)

Cycle 15 GMT 11/ 2/2018 15:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.04 5 15.24 465 35 0.04 / 90.51 3 3
2 7 1735.88 44 14.51 2612 1668 1.70 / 92.18 3 3
3 13 1158.28 22 14.74 1852 601 2.30 / 92.78 2 3
4 13 588.16 22 14.95 1138 374 2.68 / 93.15 2 3
5 13 70.52 22 15.24 430 144 2.82 / 93.30 3 3
6 8 0.20 165 15.23 320 804 3.63 / 94.10 3 3
Average= 47.05
(KJ/cycle)

Cycle 14 GMT 1/ 2/2018 20:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.20 7 15.58 462 50 0.05 / 86.96 3 3
2 7 1641.68 44 14.55 2508 1606 1.66 / 88.56 3 3
3 13 1085.04 22 14.77 1753 570 2.23 / 89.13 2 3
4 13 643.56 22 14.93 1218 400 2.63 / 89.53 2 3
5 13 35.60 22 15.26 378 127 2.75 / 89.66 3 3
6 8 0.00 165 15.24 324 815 3.57 / 90.48 3 3
Average= 90.48
(KJ/cycle)

Cycle 9 GMT 22/ 1/2018 17:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.48 105 15.20 465 742 0.74 / 82.52 3 3
2 2 160.16 27 15.28 539 222 0.96 / 82.74 3 3
3 3 877.84 -2 15.62 0 0 0.22 / 82.74 3 3
4 7 1987.44 44 14.43 2953 1875 2.84 / 84.62 3 3
5 13 1566.92 22 14.58 2409 773 3.61 / 85.39 2 3
6 13 837.96 22 14.84 1436 469 4.08 / 85.86 2 3
7 13 275.20 22 15.11 739 246 4.33 / 86.11 2 3
8 8 0.08 165 15.24 319 802 5.13 / 86.91 3 3
Average= 8.69
(KJ/cycle)

Cycle 8 GMT 12/ 1/2018 16:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.52 37 15.20 472 265 0.27 / 33.21 3 3
2 10 1035.04 5 15.02 1473 111 0.38 / 33.33 3 3
3 10 1072.56 4 15.10 1424 86 0.46 / 33.41 2 3
4 10 1133.56 3 15.01 1564 70 0.53 / 33.48 2 3
5 10 1174.88 4 15.04 1498 90 0.62 / 33.57 2 3
6 10 1213.12 4 14.99 1640 98 0.72 / 33.67 2 3
7 10 1248.24 3 15.10 1420 64 0.79 / 33.73 2 3
8 10 1279.92 3 15.00 1680 76 0.86 / 33.81 2 3
9 10 1322.08 4 15.04 1627 98 0.96 / 33.91 2 3
10 10 1365.08 4 15.06 1509 91 1.05 / 34.00 2 3
11 3 1365.64 9 14.84 1713 229 1.28 / 34.23 2 3
12 3 1615.80 15 14.70 2074 457 1.74 / 34.68 2 3
13 5 1887.72 22 14.75 1934 628 2.36 / 35.31 2 3
14 5 1980.72 25 14.53 2422 880 3.24 / 36.19 2 3
15 5 1981.00 25 14.73 2213 815 4.06 / 37.01 2 3
16 5 1981.64 25 14.81 1920 711 4.77 / 37.72 2 3
17 5 1972.00 24 14.57 2292 801 5.57 / 38.52 2 3
18 5 1986.24 25 14.61 2277 832 6.40 / 39.35 2 3
19 5 1970.12 24 14.55 2456 858 7.26 / 40.21 2 3
20 5 1978.60 25 14.66 2287 838 8.10 / 41.05 2 3
21 5 1978.00 25 14.78 2177 804 8.90 / 41.85 2 3
22 5 1985.64 25 14.67 2260 829 9.73 / 42.68 2 3
23 5 1982.80 25 14.81 2117 784 10.52 / 43.46 2 3
24 5 1971.60 24 14.73 2018 713 11.23 / 44.18 2 3
25 5 1986.12 25 14.74 2208 814 12.04 / 44.99 2 3
26 5 1983.72 25 14.79 1964 726 12.77 / 45.72 2 3
27 5 1966.12 24 14.74 2012 712 13.48 / 46.43 2 3
28 5 1987.64 25 14.79 2144 793 14.27 / 47.22 2 3
29 5 1986.92 25 14.40 3074 1107 15.38 / 48.33 2 3
30 5 1655.00 16 14.59 2629 614 15.99 / 48.94 2 3
31 5 1904.56 23 14.58 2388 801 16.79 / 49.74 2 3
32 5 1978.12 25 14.74 2207 813 17.61 / 50.56 2 3
33 5 1977.00 24 14.55 2451 856 18.46 / 51.41 2 3
34 5 1982.84 25 14.59 2265 826 19.29 / 52.24 2 3
35 5 1985.56 25 14.57 2379 867 20.16 / 53.10 2 3
36 5 1984.96 25 14.82 2046 758 20.91 / 53.86 2 3
37 5 1979.92 25 14.56 2413 878 21.79 / 54.74 2 3
38 5 1988.24 25 14.57 2316 844 22.64 / 55.58 2 3
39 5 1976.00 24 14.72 2070 731 23.37 / 56.32 2 3
40 5 1986.72 25 14.79 1961 725 24.09 / 57.04 2 3
41 5 1969.44 24 14.41 3092 1069 25.16 / 58.11 2 3
42 5 1611.88 15 14.59 2597 568 25.73 / 58.68 2 3
43 5 1448.72 11 14.74 2341 380 26.11 / 59.06 2 3
44 5 1811.20 20 14.50 2842 824 26.93 / 59.88 2 3
45 5 1643.00 16 14.59 2635 615 27.55 / 60.50 2 3
46 5 1477.88 12 14.73 2374 420 27.97 / 60.92 2 3
47 5 1862.16 22 14.50 2928 934 28.90 / 61.85 2 3
48 5 1969.64 24 14.37 3051 1052 29.95 / 62.90 2 3
49 5 1574.32 14 14.62 2538 519 30.47 / 63.42 2 3
50 5 1477.20 12 14.70 2414 426 30.90 / 63.85 2 3
51 5 1498.32 13 14.70 2418 462 31.36 / 64.31 2 3
52 5 1521.24 13 14.70 2411 461 31.82 / 64.77 2 3
53 5 1895.76 22 14.49 2952 941 32.76 / 65.71 2 3
54 5 1976.28 24 14.42 3076 1065 33.83 / 66.78 2 3
55 5 1978.44 25 14.34 3123 1120 34.95 / 67.90 2 3
56 5 1596.84 15 14.61 2592 568 35.52 / 68.47 2 3
57 5 1888.20 22 14.43 3008 955 36.47 / 69.42 2 3
58 5 1982.04 25 14.37 3092 1111 37.58 / 70.53 2 3
59 5 1643.84 16 14.57 2685 626 38.21 / 71.16 2 3
60 5 1922.76 23 14.39 3020 1000 39.21 / 72.16 2 3
61 5 1670.24 17 14.56 2674 662 39.87 / 72.82 2 3
62 5 1532.32 13 14.65 2461 469 40.34 / 73.29 2 3
63 5 1899.48 23 14.46 2977 990 41.33 / 74.28 2 3
64 5 1973.72 24 14.38 3095 1068 42.40 / 75.35 2 3
65 5 1990.32 25 14.37 3115 1119 43.51 / 76.46 2 3
66 5 1987.28 25 14.35 3115 1118 44.63 / 77.58 2 3
67 7 1991.88 44 14.44 2973 1889 46.52 / 79.47 3 3
68 13 1574.52 22 14.59 2419 776 47.30 / 80.25 2 3
69 13 839.44 22 14.84 1476 482 47.78 / 80.73 2 3
70 13 273.36 22 15.14 712 237 48.02 / 80.97 2 3
71 8 0.04 165 15.26 323 813 48.83 / 81.78 3 3
Average= 9.09
(KJ/cycle)

Cycle 7 GMT 2/ 1/2018 14:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.48 26 15.23 417 165 0.17 / 27.99 3 3
2 10 1010.96 5 15.03 1484 112 0.28 / 28.10 3 3
3 10 1045.08 3 15.18 1230 56 0.33 / 28.16 3 3
4 3 1093.24 2 15.11 1444 44 0.38 / 28.20 2 3
5 3 1049.96 1 15.36 1342 21 0.40 / 28.22 2 3
6 7 1982.00 44 14.78 1930 1255 1.65 / 29.48 3 3
7 13 1853.32 22 14.73 2099 680 2.33 / 30.16 2 3
8 13 1575.96 22 14.79 1788 582 2.91 / 30.74 2 3
9 13 1163.92 22 14.82 1457 475 3.39 / 31.21 2 3
10 13 745.40 22 14.95 1087 358 3.75 / 31.57 2 3
11 13 490.20 22 15.03 833 275 4.02 / 31.85 2 3
12 13 234.36 22 15.16 556 185 4.21 / 32.03 3 3
13 13 63.56 22 15.23 379 127 4.33 / 32.16 3 3
14 8 0.28 165 15.22 315 791 5.13 / 32.95 3 3
Average= 4.12
(KJ/cycle)

Cycle 6 GMT 23/12/2017 13:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.88 22 15.24 351 118 0.12 / 23.61 3 3
2 10 1056.32 4 14.96 1811 108 0.23 / 23.72 3 3
3 3 1033.16 1 15.21 1766 27 0.25 / 23.75 2 3
4 7 1979.20 44 14.46 2870 1826 2.08 / 25.58 3 3
5 13 1562.68 22 14.62 2316 745 2.82 / 26.32 2 3
6 13 864.60 22 14.85 1427 466 3.29 / 26.79 2 3
7 13 299.68 22 15.10 746 248 3.54 / 27.03 2 3
8 8 0.04 165 15.24 314 790 4.33 / 27.82 3 3
Average= 3.97
(KJ/cycle)

Cycle 5 GMT 13/12/2017 11:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.12 23 15.23 469 164 0.16 / 18.93 3 3
2 3 927.96 -1 15.60 0 0 0.00 / 18.93 3 3
3 7 1961.52 45 14.49 2833 1847 2.01 / 20.77 3 3
4 13 1521.84 22 14.62 2274 731 2.74 / 21.50 2 3
5 13 1079.96 22 14.74 1804 585 3.33 / 22.09 2 3
6 13 327.60 22 15.09 779 259 3.59 / 22.35 2 3
7 8 0.04 240 15.23 314 1148 4.73 / 23.50 3 6
Average= 3.92
(KJ/cycle)

Cycle 4 GMT 3/12/2017 11:13: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.24 22 15.24 461 155 0.15 / 14.80 3 3
2 7 1513.92 74 14.63 2273 2461 2.62 / 17.26 3 3
3 13 436.96 25 15.05 959 361 2.98 / 17.62 2 3
4 8 -0.08 240 15.25 312 1142 4.12 / 18.76 3 4
Average= 3.75
(KJ/cycle)

Cycle 3 GMT 2/12/2017 11:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.48 22 15.24 447 150 0.15 / 10.73 3 3
2 7 1507.36 74 14.63 2280 2468 2.62 / 13.19 3 3
3 13 347.28 25 15.10 826 312 2.93 / 13.51 2 3
4 8 0.08 240 15.25 311 1138 4.07 / 14.64 3 3
Average= 3.66
(KJ/cycle)

Cycle 2 GMT 1/12/2017 12:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.24 24 15.24 461 169 0.17 / 6.67 3 3
2 3 905.52 -2 15.61 0 0 0.00 / 6.67 3 3
3 7 1506.36 74 14.64 2280 2470 2.64 / 9.14 3 3
4 13 319.60 25 15.13 787 298 2.94 / 9.44 2 3
5 8 0.04 240 15.25 311 1138 4.07 / 10.58 3 3
Average= 3.53
(KJ/cycle)

Cycle 1 GMT 30/11/2017 13:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.92 25 15.46 369 143 0.14 / 1.81 3 3
2 10 1013.96 8 15.01 1841 221 0.36 / 2.03 3 3
3 10 1087.88 7 14.94 1958 205 0.57 / 2.24 3 3
4 10 1145.24 5 14.92 1949 145 0.71 / 2.38 3 3
5 3 1146.04 4 14.94 1935 116 0.83 / 2.50 3 3
6 3 1390.20 10 14.75 2312 341 1.17 / 2.84 2 3
7 7 1422.88 74 14.61 2156 2331 3.50 / 5.17 3 3
8 13 126.84 25 15.25 501 191 3.69 / 5.36 3 3
9 8 0.00 240 15.26 311 1139 4.83 / 6.50 3 5
Average= 3.25
(KJ/cycle)

Cycle 0 GMT 30/11/2017 3: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 75.84 25 15.62 351 137 0.14 / 0.14 3 3
2 7 86.08 74 15.59 365 421 0.56 / 0.56 3 3
3 13 46.24 25 15.57 319 124 0.68 / 0.68 3 3
4 8 0.40 240 15.52 265 987 1.67 / 1.67 3 3
Average= 1.67