SIO Argo Site:
Pump Diagnostics Page   



Serial= 8610 WMO= 3901792

Return

←PreviousNext→

Cycle 159 GMT 10/ 2/2022 10:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.36 27 14.95 505 204 0.20 / 732.24 1 1
2 12 1246.20 2 14.89 2177 65 0.27 / 732.31 1 1
3 7 2004.44 48 14.18 3022 2057 2.33 / 734.36 1 1
4 13 1453.96 22 14.36 2344 741 3.07 / 735.11 1 1
5 13 892.32 22 14.55 1587 508 3.57 / 735.61 1 1
6 13 299.72 22 14.83 792 258 3.83 / 735.87 1 1
7 8 0.04 165 14.97 337 832 4.66 / 736.70 1 2
Average= 4.60
(KJ/cycle)

Cycle 158 GMT 31/ 1/2022 10:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.72 27 14.96 506 204 0.20 / 727.53 1 1
2 12 1252.04 2 14.89 2156 64 0.27 / 727.60 1 1
3 7 2000.72 47 14.19 3032 2022 2.29 / 729.62 1 1
4 13 1578.76 22 14.32 2511 791 3.08 / 730.41 1 1
5 13 996.72 22 14.51 1731 553 3.63 / 730.96 1 1
6 13 272.76 22 14.85 750 245 3.88 / 731.21 1 1
7 8 0.00 165 14.97 336 830 4.71 / 732.04 1 2
Average= 4.60
(KJ/cycle)

Cycle 157 GMT 21/ 1/2022 10: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.12 27 14.95 508 205 0.21 / 722.77 1 1
2 12 1228.76 2 14.89 2114 63 0.27 / 722.83 1 1
3 7 2003.72 48 14.19 3019 2056 2.32 / 724.88 1 1
4 13 1729.88 22 14.27 2710 851 3.18 / 725.74 1 1
5 13 871.44 22 14.56 1556 498 3.67 / 726.23 1 1
6 13 301.84 22 14.83 794 259 3.93 / 726.49 1 1
7 8 0.16 165 14.97 339 837 4.77 / 727.33 1 2
Average= 4.60
(KJ/cycle)

Cycle 156 GMT 11/ 1/2022 9:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 28 14.95 505 211 0.21 / 718.06 1 1
2 12 1229.96 2 14.90 2140 64 0.28 / 718.13 1 1
3 7 2003.28 47 14.19 3027 2019 2.29 / 720.15 1 1
4 13 1584.88 22 14.32 2506 789 3.08 / 720.93 1 1
5 13 988.44 22 14.51 1713 547 3.63 / 721.48 1 1
6 13 260.08 22 14.85 731 239 3.87 / 721.72 1 1
7 8 0.00 165 14.97 340 840 4.71 / 722.56 1 2
Average= 4.60
(KJ/cycle)

Cycle 155 GMT 1/ 1/2022 9: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.92 28 14.95 500 209 0.21 / 713.55 1 1
2 12 1245.36 2 14.90 2153 64 0.27 / 713.62 1 1
3 7 2001.60 47 14.19 3007 2005 2.28 / 715.62 1 1
4 13 1458.52 22 14.36 2310 730 3.01 / 716.35 1 1
5 13 757.28 22 14.61 1404 451 3.46 / 716.81 1 1
6 13 202.32 22 14.89 644 211 3.67 / 717.02 1 1
7 8 0.04 165 14.97 338 835 4.51 / 717.85 1 2
Average= 4.60
(KJ/cycle)

Cycle 154 GMT 22/12/2021 8: 5: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.04 28 14.95 506 212 0.21 / 708.98 1 1
2 12 1239.76 2 14.91 2133 64 0.28 / 709.04 1 1
3 7 2004.52 48 14.19 3023 2059 2.33 / 711.10 1 1
4 13 1346.88 22 14.40 2188 693 3.03 / 711.80 1 1
5 13 926.72 22 14.54 1615 517 3.54 / 712.31 1 1
6 13 197.88 22 14.90 635 208 3.75 / 712.52 1 1
7 8 0.04 165 14.97 334 825 4.58 / 713.35 1 3
Average= 4.60
(KJ/cycle)

Cycle 153 GMT 12/12/2021 7:48:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.40 27 14.96 507 205 0.20 / 704.36 1 1
2 12 1241.52 2 14.90 2154 64 0.27 / 704.43 1 1
3 7 2002.72 47 14.19 3026 2018 2.29 / 706.45 1 1
4 13 1442.00 22 14.37 2320 733 3.02 / 707.18 1 1
5 13 879.76 22 14.57 1563 501 3.52 / 707.68 1 1
6 13 297.64 22 14.84 778 254 3.78 / 707.94 1 1
7 8 0.08 165 14.97 337 832 4.61 / 708.77 1 1
Average= 4.60
(KJ/cycle)

Cycle 152 GMT 2/12/2021 7:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.40 27 14.96 492 199 0.20 / 699.75 1 1
2 12 1243.32 2 14.90 2098 63 0.26 / 699.81 1 1
3 7 2004.48 48 14.19 3029 2063 2.32 / 701.88 1 1
4 13 1579.48 22 14.33 2495 787 3.11 / 702.66 1 1
5 13 740.48 22 14.63 1382 445 3.56 / 703.11 1 1
6 13 202.00 22 14.90 647 212 3.77 / 703.32 1 1
7 8 0.00 165 14.98 340 840 4.61 / 704.16 1 2
Average= 4.60
(KJ/cycle)

Cycle 151 GMT 22/11/2021 7: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.12 27 14.95 502 203 0.20 / 695.09 1 1
2 12 1255.08 2 14.89 2182 65 0.27 / 695.15 1 1
3 7 2000.84 47 14.20 3015 2012 2.28 / 697.16 1 1
4 13 1586.08 22 14.33 2500 788 3.07 / 697.95 1 1
5 13 875.84 22 14.57 1566 502 3.57 / 698.46 1 1
6 13 293.72 22 14.84 779 254 3.82 / 698.71 1 1
7 8 0.08 165 14.97 341 842 4.67 / 699.55 1 2
Average= 4.60
(KJ/cycle)

Cycle 150 GMT 12/11/2021 6:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.44 27 14.95 516 208 0.21 / 690.46 1 1
2 12 1239.36 2 14.89 2136 64 0.27 / 690.53 1 1
3 7 2002.00 47 14.21 3019 2016 2.29 / 692.54 1 1
4 13 1462.48 22 14.37 2327 736 3.02 / 693.28 1 1
5 13 887.64 22 14.56 1570 503 3.53 / 693.78 1 1
6 13 309.04 22 14.83 803 262 3.79 / 694.04 1 1
7 8 0.16 165 14.97 341 842 4.63 / 694.89 1 3
Average= 4.60
(KJ/cycle)

Cycle 149 GMT 2/11/2021 6:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.96 27 14.96 521 210 0.21 / 685.66 1 1
2 12 1242.16 2 14.89 2137 64 0.27 / 685.73 1 1
3 7 2001.88 48 14.20 3016 2056 2.33 / 687.78 1 1
4 13 1578.52 22 14.33 2487 784 3.11 / 688.57 1 1
5 13 978.76 22 14.52 1694 541 3.65 / 689.11 1 1
6 13 378.12 22 14.79 907 295 3.95 / 689.40 1 1
7 8 0.08 165 14.97 345 852 4.80 / 690.25 1 4
Average= 4.60
(KJ/cycle)

Cycle 148 GMT 23/10/2021 6:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.32 27 14.95 510 206 0.21 / 680.94 1 1
2 12 1242.72 2 14.93 2132 64 0.27 / 681.01 1 1
3 7 2004.16 47 14.20 3019 2015 2.28 / 683.02 1 1
4 13 1585.60 22 14.33 2495 787 3.07 / 683.81 1 1
5 13 1007.40 22 14.51 1751 559 3.63 / 684.37 1 1
6 13 263.40 22 14.86 742 243 3.87 / 684.61 1 1
7 8 0.12 165 14.98 340 840 4.71 / 685.45 1 5
Average= 4.60
(KJ/cycle)

Cycle 147 GMT 13/10/2021 5:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.84 27 14.96 496 200 0.20 / 676.32 1 1
2 12 1235.08 2 14.91 2145 64 0.26 / 676.38 1 1
3 7 2004.76 48 14.19 3029 2063 2.33 / 678.45 1 1
4 13 1439.08 22 14.38 2309 730 3.06 / 679.18 1 1
5 13 754.12 22 14.63 1399 450 3.51 / 679.63 1 1
6 13 315.40 22 14.83 810 264 3.77 / 679.89 1 1
7 8 0.08 165 14.97 343 847 4.62 / 680.74 1 2
Average= 4.60
(KJ/cycle)

Cycle 146 GMT 3/10/2021 5:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.72 27 14.96 510 206 0.21 / 671.76 1 1
2 12 1233.88 2 14.90 2150 64 0.27 / 671.82 1 1
3 7 2002.56 47 14.19 3036 2025 2.29 / 673.85 1 1
4 13 1439.68 22 14.38 2313 732 3.03 / 674.58 1 1
5 13 880.92 22 14.57 1573 504 3.53 / 675.08 1 1
6 13 181.36 22 14.92 613 201 3.73 / 675.28 1 1
7 8 0.00 165 14.98 338 835 4.57 / 676.12 1 3
Average= 4.60
(KJ/cycle)

Cycle 145 GMT 23/ 9/2021 4:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.76 27 14.94 521 210 0.21 / 667.21 1 1
2 12 1252.44 2 14.91 2153 64 0.27 / 667.28 1 1
3 7 2002.00 47 14.19 3030 2021 2.30 / 669.30 1 1
4 13 1447.00 22 14.37 2330 737 3.03 / 670.04 1 1
5 13 770.80 22 14.62 1427 459 3.49 / 670.49 1 1
6 13 203.80 22 14.91 646 212 3.70 / 670.71 1 1
7 8 -0.04 165 14.98 342 845 4.55 / 671.55 1 2
Average= 4.60
(KJ/cycle)

Cycle 144 GMT 13/ 9/2021 4:34:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.92 27 14.97 500 202 0.20 / 662.45 1 1
2 12 1232.56 2 14.92 2114 63 0.27 / 662.51 1 1
3 7 2003.52 47 14.20 3018 2014 2.28 / 664.52 1 1
4 13 1592.52 22 14.33 2514 793 3.07 / 665.32 1 1
5 13 753.64 22 14.64 1393 449 3.52 / 665.77 1 1
6 13 322.60 22 14.83 816 266 3.79 / 666.03 1 1
7 13 36.60 22 15.00 395 130 3.92 / 666.16 1 1
8 8 0.08 165 14.97 341 842 4.76 / 667.00 1 3
Average= 4.60
(KJ/cycle)

Cycle 143 GMT 3/ 9/2021 4:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.68 27 14.95 498 201 0.20 / 657.86 1 1
2 12 1240.88 2 14.90 2085 62 0.26 / 657.92 1 1
3 7 2003.20 47 14.20 3012 2010 2.27 / 659.93 1 1
4 13 1452.44 22 14.38 2317 733 3.01 / 660.66 1 1
5 13 884.72 22 14.57 1567 502 3.51 / 661.16 1 1
6 13 297.32 22 14.85 773 253 3.76 / 661.42 1 1
7 8 -0.04 165 14.98 335 828 4.59 / 662.24 1 2
Average= 4.60
(KJ/cycle)

Cycle 142 GMT 24/ 8/2021 3:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.24 27 14.97 502 203 0.20 / 652.79 1 1
2 12 1254.08 2 14.91 2142 64 0.27 / 652.85 1 1
3 7 2003.48 47 14.21 3017 2015 2.28 / 654.87 1 1
4 13 1329.00 22 14.42 2149 682 2.96 / 655.55 1 1
5 13 920.72 22 14.55 1622 519 3.48 / 656.07 1 1
6 13 320.64 22 14.83 806 263 3.75 / 656.33 1 1
7 13 17.52 22 15.01 357 118 3.86 / 656.45 1 1
8 8 0.08 165 14.97 338 835 4.70 / 657.28 1 3
9 14 0.08 75 14.94 331 371 5.07 / 657.66 1 3
Average= 4.60
(KJ/cycle)

Cycle 141 GMT 14/ 8/2021 3:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.32 27 14.97 509 206 0.21 / 648.25 1 1
2 12 1235.72 2 14.91 2150 64 0.27 / 648.31 1 1
3 7 2003.84 47 14.20 3028 2021 2.29 / 650.33 1 1
4 13 1462.88 22 14.38 2331 737 3.03 / 651.07 1 1
5 13 768.52 22 14.63 1400 451 3.48 / 651.52 1 1
6 13 222.32 22 14.90 673 221 3.70 / 651.74 1 1
7 8 0.12 165 14.98 341 843 4.54 / 652.59 1 3
Average= 4.60
(KJ/cycle)

Cycle 140 GMT 4/ 8/2021 2:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.84 27 14.97 501 202 0.20 / 643.58 1 1
2 12 1252.68 2 14.90 2182 65 0.27 / 643.64 1 1
3 7 2002.88 47 14.21 3007 2008 2.28 / 645.65 1 1
4 13 1595.72 22 14.34 2495 787 3.06 / 646.44 1 1
5 13 879.72 22 14.58 1572 504 3.57 / 646.94 1 1
6 13 300.44 22 14.85 791 258 3.83 / 647.20 1 1
7 8 -0.04 165 14.98 341 843 4.67 / 648.04 1 2
Average= 4.60
(KJ/cycle)

Cycle 139 GMT 25/ 7/2021 2:37:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.56 27 14.98 512 207 0.21 / 638.88 1 1
2 12 1240.44 2 14.91 2150 64 0.27 / 638.95 1 1
3 7 2002.52 47 14.21 3016 2014 2.29 / 640.96 1 1
4 13 1579.08 22 14.34 2507 791 3.08 / 641.75 1 1
5 13 991.08 22 14.54 1706 546 3.62 / 642.30 1 1
6 13 256.12 22 14.88 720 236 3.86 / 642.53 1 1
7 8 -0.04 165 14.98 340 840 4.70 / 643.38 1 1
Average= 4.60
(KJ/cycle)

Cycle 138 GMT 15/ 7/2021 2:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.40 27 14.97 501 202 0.20 / 634.21 1 1
2 12 1244.20 2 14.90 2170 65 0.27 / 634.28 1 1
3 7 2004.36 47 14.21 3031 2024 2.29 / 636.30 1 1
4 13 1587.44 22 14.33 2502 789 3.08 / 637.09 1 1
5 13 870.04 22 14.58 1546 496 3.58 / 637.58 1 1
6 13 284.36 22 14.86 771 252 3.83 / 637.84 1 1
7 8 0.16 165 14.99 340 841 4.67 / 638.68 1 2
Average= 4.59
(KJ/cycle)

Cycle 137 GMT 5/ 7/2021 2: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.40 27 14.98 491 199 0.20 / 629.62 1 1
2 12 1242.12 2 14.91 2157 64 0.26 / 629.69 1 1
3 7 2001.60 47 14.20 3028 2021 2.28 / 631.71 1 1
4 13 1449.44 22 14.38 2326 736 3.02 / 632.45 1 1
5 13 763.32 22 14.63 1412 454 3.47 / 632.90 1 1
6 13 333.12 22 14.83 832 271 3.75 / 633.17 1 1
7 8 0.04 165 14.99 338 836 4.58 / 634.01 1 2
Average= 4.59
(KJ/cycle)

Cycle 136 GMT 25/ 6/2021 1:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.64 27 14.99 498 202 0.20 / 625.06 1 1
2 12 1256.56 2 14.90 2187 65 0.27 / 625.12 1 1
3 7 2004.92 48 14.20 3021 2059 2.33 / 627.18 1 1
4 13 1587.28 22 14.34 2491 786 3.11 / 627.97 1 1
5 13 759.28 22 14.64 1400 451 3.56 / 628.42 1 1
6 13 204.64 22 14.92 643 211 3.77 / 628.63 1 1
7 8 0.24 165 15.00 321 794 4.57 / 629.43 1 2
Average= 4.59
(KJ/cycle)

Cycle 135 GMT 15/ 6/2021 0:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.32 27 14.98 509 206 0.21 / 620.43 1 1
2 12 1238.60 2 14.92 2137 64 0.27 / 620.49 1 1
3 7 2005.08 47 14.22 3015 2015 2.28 / 622.51 1 1
4 13 1463.56 22 14.38 2332 738 3.02 / 623.25 1 1
5 13 897.32 22 14.58 1584 508 3.53 / 623.75 1 1
6 13 319.56 22 14.84 815 266 3.80 / 624.02 1 1
7 8 -0.04 165 14.99 339 838 4.64 / 624.86 1 2
Average= 4.59
(KJ/cycle)

Cycle 134 GMT 5/ 6/2021 0:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.92 27 14.99 494 200 0.20 / 615.59 1 1
2 12 1240.56 2 14.92 2118 63 0.26 / 615.65 1 1
3 7 2002.88 48 14.21 3010 2053 2.32 / 617.71 1 1
4 13 1586.44 22 14.34 2499 788 3.10 / 618.50 1 1
5 13 993.32 22 14.54 1697 543 3.65 / 619.04 1 1
6 13 264.00 22 14.88 729 239 3.89 / 619.28 1 1
7 13 26.32 22 15.02 371 123 4.01 / 619.40 1 1
8 8 0.04 165 14.99 333 824 4.83 / 620.22 1 2
Average= 4.59
(KJ/cycle)

Cycle 133 GMT 26/ 5/2021 0: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.08 27 14.98 497 201 0.20 / 611.00 1 1
2 12 1234.52 2 14.91 2106 63 0.26 / 611.06 1 1
3 7 2003.28 47 14.21 3020 2017 2.28 / 613.08 1 1
4 13 1584.92 22 14.36 2453 775 3.06 / 613.85 1 1
5 13 856.72 22 14.60 1507 484 3.54 / 614.33 1 1
6 13 282.04 22 14.87 746 244 3.78 / 614.58 1 1
7 8 0.08 165 15.00 328 812 4.60 / 615.39 1 2
Average= 4.59
(KJ/cycle)

Cycle 132 GMT 15/ 5/2021 23:37:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.76 27 14.99 502 203 0.20 / 606.24 1 1
2 12 1241.04 2 14.91 2149 64 0.27 / 606.30 1 1
3 7 2011.68 47 14.21 3021 2018 2.28 / 608.32 1 1
4 13 1588.20 22 14.35 2496 788 3.07 / 609.11 1 1
5 13 871.24 22 14.60 1543 496 3.57 / 609.60 1 1
6 13 288.56 22 14.87 766 251 3.82 / 609.85 1 1
7 13 12.80 22 15.03 348 115 3.93 / 609.97 1 1
8 8 0.08 165 14.99 334 826 4.76 / 610.80 1 2
Average= 4.59
(KJ/cycle)

Cycle 131 GMT 5/ 5/2021 22:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.44 27 14.99 484 196 0.20 / 601.64 1 1
2 12 1235.44 2 14.90 2112 63 0.26 / 601.71 1 1
3 7 2004.68 47 14.20 3019 2015 2.27 / 603.72 1 1
4 13 1452.08 22 14.39 2319 734 3.01 / 604.45 1 1
5 13 878.16 22 14.58 1563 501 3.51 / 604.96 1 1
6 13 298.44 22 14.86 788 258 3.77 / 605.21 1 1
7 8 0.04 165 15.00 332 822 4.59 / 606.03 1 2
Average= 4.59
(KJ/cycle)

Cycle 130 GMT 25/ 4/2021 22:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.04 27 15.00 491 199 0.20 / 597.14 1 1
2 12 1231.44 3 14.84 2136 95 0.29 / 597.23 1 1
3 7 1992.12 48 14.21 2996 2044 2.34 / 599.27 1 1
4 13 1311.88 21 14.44 2138 648 2.99 / 599.92 1 1
5 13 781.00 21 14.63 1428 439 3.42 / 600.36 1 1
6 13 342.72 21 14.83 846 263 3.69 / 600.62 1 1
7 8 0.12 165 15.00 332 822 4.51 / 601.45 1 1
Average= 4.59
(KJ/cycle)

Cycle 129 GMT 15/ 4/2021 20:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.24 27 15.00 485 196 0.20 / 592.52 1 1
2 12 1232.68 3 14.84 2121 94 0.29 / 592.61 1 1
3 7 1997.84 49 14.20 3001 2088 2.38 / 594.70 1 1
4 13 1548.68 21 14.36 2438 735 3.11 / 595.44 1 1
5 13 832.84 21 14.61 1505 462 3.58 / 595.90 1 1
6 13 269.96 21 14.88 734 229 3.81 / 596.13 1 1
7 8 0.12 165 15.01 326 807 4.61 / 596.94 1 3
Average= 4.59
(KJ/cycle)

Cycle 128 GMT 5/ 4/2021 19:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.32 27 14.99 490 198 0.20 / 587.95 1 1
2 12 1242.52 3 14.84 2127 95 0.29 / 588.05 1 1
3 7 1994.84 48 14.20 3033 2067 2.36 / 590.11 1 1
4 13 1438.72 21 14.39 2324 702 3.06 / 590.81 1 1
5 13 862.80 21 14.59 1537 471 3.53 / 591.29 1 1
6 13 281.68 21 14.87 755 236 3.77 / 591.52 1 1
7 8 0.00 165 15.01 324 802 4.57 / 592.32 1 2
Average= 4.59
(KJ/cycle)

Cycle 127 GMT 26/ 3/2021 17:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.48 27 15.00 498 202 0.20 / 583.20 1 1
2 12 1234.44 2 14.91 2164 65 0.27 / 583.27 1 1
3 7 2004.44 48 14.21 3012 2054 2.32 / 585.32 1 1
4 13 1568.96 21 14.36 2462 742 3.06 / 586.07 1 1
5 13 990.68 21 14.54 1693 517 3.58 / 586.58 1 1
6 13 276.08 21 14.88 746 233 3.81 / 586.82 1 1
7 13 27.96 21 15.03 373 118 3.93 / 586.93 1 1
8 8 -0.04 165 15.00 331 819 4.75 / 587.75 1 2
Average= 4.59
(KJ/cycle)

Cycle 126 GMT 16/ 3/2021 17:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.88 27 15.00 488 198 0.20 / 578.74 1 1
2 12 1232.40 2 14.90 2099 63 0.26 / 578.80 1 1
3 7 2004.24 48 14.21 3014 2056 2.32 / 580.86 1 1
4 13 1456.96 21 14.39 2320 701 3.02 / 581.56 1 1
5 13 768.24 21 14.65 1391 428 3.45 / 581.98 1 1
6 13 225.52 21 14.92 656 206 3.65 / 582.19 1 1
7 8 0.16 165 15.01 328 812 4.46 / 583.00 1 2
Average= 4.59
(KJ/cycle)

Cycle 125 GMT 6/ 3/2021 16:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.24 27 14.99 492 199 0.20 / 574.11 1 1
2 12 1236.96 2 14.93 2140 64 0.26 / 574.17 1 1
3 7 2001.84 48 14.21 3022 2061 2.32 / 576.23 1 1
4 13 1596.32 21 14.36 2488 750 3.07 / 576.98 1 1
5 13 878.92 21 14.60 1565 480 3.55 / 577.46 1 1
6 13 323.72 21 14.85 819 255 3.81 / 577.72 1 1
7 8 0.12 165 15.01 331 820 4.63 / 578.54 1 2
Average= 4.59
(KJ/cycle)

Cycle 124 GMT 24/ 2/2021 15:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.40 27 14.99 487 197 0.20 / 569.46 1 1
2 12 1247.44 2 14.91 2126 63 0.26 / 569.52 1 1
3 7 2001.72 48 14.21 3029 2066 2.33 / 571.59 1 1
4 13 1460.44 21 14.40 2319 701 3.03 / 572.29 1 1
5 13 765.40 21 14.65 1403 432 3.46 / 572.72 1 1
6 13 329.64 21 14.85 827 258 3.72 / 572.98 1 1
7 13 36.72 21 15.02 381 120 3.84 / 573.10 1 1
8 8 0.04 165 15.00 327 809 4.65 / 573.91 1 2
Average= 4.59
(KJ/cycle)

Cycle 123 GMT 14/ 2/2021 15:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.20 27 15.00 488 198 0.20 / 564.80 1 1
2 12 1238.56 2 14.91 2119 63 0.26 / 564.86 1 1
3 7 2003.80 48 14.23 2996 2046 2.31 / 566.91 1 1
4 13 1454.52 20 14.42 2294 662 2.97 / 567.57 1 1
5 13 892.84 20 14.61 1562 456 3.43 / 568.03 1 1
6 13 473.44 20 14.78 1017 301 3.73 / 568.33 1 1
7 13 37.08 20 15.03 383 115 3.84 / 568.44 1 1
8 8 0.04 165 15.00 332 822 4.66 / 569.26 1 2
Average= 4.59
(KJ/cycle)

Cycle 122 GMT 4/ 2/2021 14:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.80 27 14.99 488 198 0.20 / 560.02 1 1
2 12 1227.76 2 14.92 2144 64 0.26 / 560.09 1 1
3 7 2003.20 48 14.23 2990 2042 2.30 / 562.13 1 1
4 13 1734.28 20 14.32 2693 771 3.08 / 562.90 1 1
5 13 989.88 20 14.57 1703 496 3.57 / 563.40 1 1
6 13 408.08 20 14.81 933 276 3.85 / 563.67 1 1
7 13 26.32 20 15.04 371 112 3.96 / 563.78 1 1
8 8 0.04 165 15.01 330 817 4.78 / 564.60 1 2
Average= 4.59
(KJ/cycle)

Cycle 121 GMT 25/ 1/2021 14: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.52 27 15.00 498 202 0.20 / 555.33 1 1
2 12 1247.32 2 14.90 2150 64 0.27 / 555.40 1 1
3 7 2001.68 48 14.22 3008 2053 2.32 / 557.45 1 1
4 13 1443.24 20 14.43 2280 658 2.98 / 558.11 1 1
5 13 1010.92 20 14.56 1712 499 3.48 / 558.61 1 1
6 13 419.60 20 14.81 947 281 3.76 / 558.89 1 1
7 13 61.08 20 15.02 415 125 3.88 / 559.01 1 1
8 8 0.08 165 15.01 328 812 4.69 / 559.82 1 1
Average= 4.59
(KJ/cycle)

Cycle 120 GMT 15/ 1/2021 13:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.00 27 15.00 495 200 0.20 / 550.76 1 1
2 12 1239.88 2 14.93 2135 64 0.26 / 550.83 1 1
3 7 2000.96 50 14.20 3007 2135 2.40 / 552.96 1 1
4 13 1432.48 20 14.42 2276 656 3.06 / 553.62 1 1
5 13 859.80 20 14.61 1540 450 3.51 / 554.07 1 1
6 13 293.76 20 14.88 783 233 3.74 / 554.30 1 1
7 8 0.04 165 15.01 335 830 4.57 / 555.13 1 2
Average= 4.59
(KJ/cycle)

Cycle 119 GMT 5/ 1/2021 12:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.72 27 14.99 505 204 0.20 / 546.28 1 1
2 12 1243.68 2 14.92 2156 64 0.27 / 546.34 1 1
3 7 2005.92 50 14.21 2985 2121 2.39 / 548.46 1 1
4 13 1329.72 20 14.46 2134 617 3.01 / 549.08 1 1
5 13 764.56 20 14.66 1403 411 3.42 / 549.49 1 1
6 13 343.32 20 14.85 852 253 3.67 / 549.74 1 1
7 8 0.08 165 15.02 331 820 4.49 / 550.56 1 1
Average= 4.59
(KJ/cycle)

Cycle 118 GMT 26/12/2020 11:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.08 27 14.99 498 202 0.20 / 541.63 1 1
2 12 1225.84 2 14.91 2144 64 0.27 / 541.69 1 1
3 7 2002.52 50 14.21 3013 2141 2.41 / 543.83 1 1
4 13 1446.60 20 14.42 2298 663 3.07 / 544.49 1 1
5 13 1017.48 20 14.55 1744 508 3.58 / 545.00 1 1
6 13 301.36 20 14.87 792 236 3.81 / 545.24 1 1
7 8 0.04 165 15.01 337 835 4.65 / 546.07 1 2
Average= 4.59
(KJ/cycle)

Cycle 117 GMT 16/12/2020 11: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.40 27 15.00 498 202 0.20 / 536.97 1 1
2 12 1244.04 1 15.05 2182 33 0.23 / 537.00 1 1
3 7 2004.92 50 14.21 3008 2137 2.37 / 539.14 1 1
4 13 1448.96 20 14.42 2299 663 3.03 / 539.80 1 1
5 13 871.48 20 14.62 1539 450 3.48 / 540.25 1 1
6 13 297.64 20 14.88 781 232 3.72 / 540.48 1 1
7 13 16.00 20 15.05 357 107 3.82 / 540.59 1 1
8 8 -0.04 165 15.01 336 832 4.66 / 541.42 1 1
Average= 4.59
(KJ/cycle)

Cycle 116 GMT 6/12/2020 10:47:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.84 27 14.99 507 205 0.21 / 532.27 1 1
2 12 1250.32 1 15.05 2181 33 0.24 / 532.30 1 1
3 7 2004.84 50 14.21 3018 2144 2.38 / 534.45 1 1
4 13 1573.44 20 14.38 2483 714 3.10 / 535.16 1 1
5 13 991.00 20 14.56 1724 502 3.60 / 535.66 1 1
6 13 395.60 20 14.82 920 273 3.87 / 535.93 1 1
7 8 0.00 165 15.02 336 833 4.70 / 536.77 1 2
Average= 4.59
(KJ/cycle)

Cycle 115 GMT 26/11/2020 10:52:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.80 27 14.99 505 204 0.20 / 527.56 1 1
2 7 2004.20 51 14.21 3018 2187 2.39 / 529.75 1 1
3 13 1342.60 22 14.44 2181 693 3.08 / 530.44 1 1
4 13 930.00 22 14.58 1628 522 3.61 / 530.96 1 1
5 13 321.76 22 14.85 825 270 3.88 / 531.23 1 1
6 8 0.04 165 15.01 335 830 4.71 / 532.06 1 1
Average= 4.59
(KJ/cycle)

Cycle 114 GMT 16/11/2020 10:51:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.16 27 15.00 483 196 0.20 / 522.87 1 1
2 7 2002.96 50 14.22 3019 2147 2.34 / 525.02 1 1
3 13 1561.08 22 14.38 2462 779 3.12 / 525.79 1 1
4 13 837.92 22 14.62 1503 483 3.60 / 526.28 1 1
5 13 274.60 22 14.90 756 248 3.85 / 526.53 1 1
6 8 0.16 165 15.02 336 833 4.68 / 527.36 1 2
Average= 4.59
(KJ/cycle)

Cycle 113 GMT 6/11/2020 10:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.64 27 15.00 491 199 0.20 / 518.18 1 1
2 7 2002.84 50 14.23 3010 2142 2.34 / 520.32 1 1
3 13 1578.52 22 14.37 2488 787 3.13 / 521.10 1 1
4 13 868.52 22 14.62 1537 494 3.62 / 521.60 1 1
5 13 293.40 22 14.88 770 252 3.87 / 521.85 1 1
6 8 0.04 165 15.02 332 823 4.70 / 522.67 1 2
Average= 4.58
(KJ/cycle)

Cycle 112 GMT 27/10/2020 11: 1: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.24 27 15.00 487 197 0.20 / 513.64 1 1
2 7 2003.16 43 14.26 3007 1844 2.04 / 515.49 1 1
3 13 1738.04 22 14.33 2688 847 2.89 / 516.34 1 1
4 13 1027.80 22 14.55 1740 557 3.45 / 516.89 1 1
5 13 329.32 22 14.88 813 266 3.71 / 517.16 1 1
6 8 0.20 165 15.02 330 818 4.53 / 517.98 1 2
Average= 4.58
(KJ/cycle)

Cycle 111 GMT 17/10/2020 11: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.16 27 15.00 490 198 0.20 / 508.91 1 1
2 7 2004.76 44 14.25 3029 1899 2.10 / 510.81 1 1
3 13 1878.36 22 14.28 2897 910 3.01 / 511.72 1 1
4 13 1137.00 22 14.51 1901 607 3.61 / 512.32 1 1
5 13 410.48 22 14.83 938 306 3.92 / 512.63 1 1
6 8 0.00 165 15.03 330 818 4.74 / 513.45 1 2
Average= 4.58
(KJ/cycle)

Cycle 110 GMT 7/10/2020 11: 9: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.04 27 15.00 499 202 0.20 / 504.28 1 1
2 7 2001.76 43 14.25 3022 1852 2.05 / 506.14 1 1
3 13 1729.64 22 14.34 2693 850 2.90 / 506.99 1 1
4 13 1038.52 22 14.55 1771 567 3.47 / 507.55 1 1
5 13 469.64 22 14.79 1023 333 3.80 / 507.89 1 1
6 8 0.08 165 15.02 332 823 4.63 / 508.71 1 1
Average= 4.58
(KJ/cycle)

Cycle 109 GMT 27/ 9/2020 11:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.08 27 15.00 501 203 0.20 / 499.73 1 1
2 7 2003.32 43 14.26 3019 1851 2.05 / 501.59 1 1
3 13 1594.44 22 14.39 2492 789 2.84 / 502.37 1 1
4 13 1038.96 22 14.55 1764 565 3.41 / 502.94 1 1
5 13 454.00 22 14.80 999 325 3.73 / 503.26 1 1
6 8 0.12 165 15.03 330 818 4.55 / 504.08 1 2
Average= 4.58
(KJ/cycle)

Cycle 108 GMT 17/ 9/2020 11:21: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.72 27 15.00 500 202 0.20 / 494.92 1 1
2 7 2005.60 43 14.25 3030 1857 2.06 / 496.78 1 1
3 13 1874.72 22 14.29 2870 902 2.96 / 497.68 1 1
4 13 1140.44 22 14.51 1891 604 3.57 / 498.28 1 1
5 13 420.76 22 14.82 946 308 3.87 / 498.59 1 1
6 13 31.04 22 15.05 368 122 4.00 / 498.71 1 1
7 8 0.04 165 15.02 330 818 4.81 / 499.53 1 2
Average= 4.58
(KJ/cycle)

Cycle 107 GMT 7/ 9/2020 11:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 27 15.02 494 200 0.20 / 490.26 1 1
2 7 2003.80 43 14.26 3019 1851 2.05 / 492.11 1 1
3 13 1606.00 22 14.38 2502 792 2.84 / 492.90 1 1
4 13 1174.72 22 14.49 1924 613 3.46 / 493.51 1 2
5 13 589.36 22 14.73 1169 379 3.84 / 493.89 1 1
6 8 0.16 165 15.02 333 825 4.66 / 494.72 1 2
Average= 4.58
(KJ/cycle)

Cycle 106 GMT 28/ 8/2020 11:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.80 27 15.00 491 199 0.20 / 485.59 1 1
2 7 2004.76 43 14.25 3037 1861 2.06 / 487.45 1 1
3 13 1874.52 22 14.30 2865 901 2.96 / 488.35 1 1
4 13 1122.72 22 14.53 1859 594 3.56 / 488.94 1 1
5 13 403.80 22 14.84 910 297 3.85 / 489.24 1 1
6 8 0.08 165 15.03 329 816 4.67 / 490.06 1 2
Average= 4.58
(KJ/cycle)

Cycle 105 GMT 18/ 8/2020 11:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.12 27 15.01 486 197 0.20 / 480.92 1 1
2 7 2003.04 43 14.26 3025 1855 2.05 / 482.77 1 1
3 13 1590.84 22 14.39 2483 786 2.84 / 483.56 1 1
4 13 1039.60 22 14.55 1752 561 3.40 / 484.12 1 1
5 13 448.36 22 14.80 995 324 3.72 / 484.44 1 1
6 13 17.92 22 15.05 362 120 3.84 / 484.56 1 1
7 8 0.12 165 15.02 333 825 4.67 / 485.39 1 2
Average= 4.58
(KJ/cycle)

Cycle 104 GMT 8/ 8/2020 11:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.72 27 15.00 494 200 0.20 / 476.26 1 1
2 7 2009.00 43 14.26 3010 1846 2.05 / 478.10 1 1
3 13 1882.08 22 14.30 2866 902 2.95 / 479.00 1 1
4 13 1123.12 22 14.53 1854 593 3.54 / 479.60 1 1
5 13 408.12 22 14.83 925 302 3.84 / 479.90 1 1
6 8 0.12 165 15.03 332 823 4.67 / 480.72 1 2
Average= 4.58
(KJ/cycle)

Cycle 103 GMT 29/ 7/2020 11:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.92 27 15.01 490 199 0.20 / 471.64 1 1
2 7 2006.96 43 14.25 3010 1844 2.04 / 473.49 1 1
3 13 1745.12 22 14.34 2705 853 2.90 / 474.34 1 1
4 13 1029.92 22 14.56 1754 562 3.46 / 474.90 1 1
5 13 457.44 22 14.80 1003 327 3.78 / 475.23 1 1
6 8 0.16 165 15.02 333 825 4.61 / 476.06 1 1
Average= 4.58
(KJ/cycle)

Cycle 102 GMT 19/ 7/2020 11:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.00 27 15.00 507 205 0.21 / 467.06 1 1
2 7 2004.64 43 14.26 3016 1849 2.05 / 468.91 1 1
3 13 1729.08 22 14.34 2687 848 2.90 / 469.76 1 1
4 13 1007.00 22 14.57 1720 551 3.45 / 470.31 1 1
5 13 435.76 22 14.81 971 316 3.77 / 470.63 1 1
6 8 0.00 165 15.03 331 821 4.59 / 471.45 1 3
Average= 4.58
(KJ/cycle)

Cycle 101 GMT 9/ 7/2020 11:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.16 27 15.01 499 202 0.20 / 462.33 1 1
2 7 2004.44 43 14.26 3016 1849 2.05 / 464.18 1 1
3 13 1746.08 22 14.34 2690 849 2.90 / 465.02 1 1
4 13 1037.16 22 14.56 1735 556 3.46 / 465.58 1 1
5 13 461.92 22 14.80 1002 326 3.78 / 465.91 1 1
6 13 18.52 22 15.06 358 119 3.90 / 466.02 1 1
7 8 0.16 165 15.02 335 830 4.73 / 466.86 1 3
Average= 4.58
(KJ/cycle)

Cycle 100 GMT 29/ 6/2020 11:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.04 27 15.00 496 201 0.20 / 457.66 1 1
2 7 2003.64 43 14.26 3032 1859 2.06 / 459.52 1 1
3 13 1741.68 22 14.35 2684 847 2.91 / 460.37 1 1
4 13 1163.36 22 14.51 1936 618 3.53 / 460.99 1 1
5 13 433.64 22 14.82 959 313 3.84 / 461.30 1 1
6 8 0.04 165 15.03 333 826 4.66 / 462.12 1 2
Average= 4.58
(KJ/cycle)

Cycle 99 GMT 19/ 6/2020 11:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.16 27 15.00 498 202 0.20 / 452.90 1 1
2 7 2003.32 43 14.25 3048 1868 2.07 / 454.77 1 1
3 13 1606.24 22 14.39 2507 794 2.86 / 455.56 1 1
4 13 1170.72 22 14.50 1936 618 3.48 / 456.18 1 1
5 13 432.60 22 14.81 979 319 3.80 / 456.50 1 1
6 13 34.76 22 15.04 386 128 3.93 / 456.62 1 1
7 8 0.08 165 15.01 338 837 4.76 / 457.46 1 3
Average= 4.57
(KJ/cycle)

Cycle 98 GMT 9/ 6/2020 11:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.32 27 15.01 496 201 0.20 / 448.18 1 1
2 7 2003.16 43 14.26 3021 1852 2.05 / 450.04 1 1
3 13 1741.04 22 14.35 2702 853 2.91 / 450.89 1 1
4 13 1035.84 22 14.56 1761 564 3.47 / 451.45 1 1
5 13 343.24 22 14.86 861 281 3.75 / 451.73 1 1
6 13 19.96 22 15.05 367 122 3.87 / 451.86 1 1
7 8 -0.04 165 15.02 339 840 4.71 / 452.70 1 4
Average= 4.57
(KJ/cycle)

Cycle 97 GMT 30/ 5/2020 11:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.24 27 15.00 494 200 0.20 / 443.54 1 1
2 7 2004.56 43 14.26 3026 1855 2.06 / 445.40 1 1
3 13 1600.36 22 14.38 2503 792 2.85 / 446.19 1 1
4 13 923.72 22 14.61 1623 522 3.37 / 446.71 1 1
5 13 373.00 22 14.85 895 292 3.66 / 447.00 1 1
6 13 49.32 22 15.03 416 138 3.80 / 447.14 1 1
7 8 0.00 165 15.01 340 842 4.64 / 447.98 1 13
Average= 4.57
(KJ/cycle)

Cycle 96 GMT 20/ 5/2020 11:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.32 27 15.02 504 204 0.20 / 438.80 1 1
2 7 2002.76 43 14.27 3014 1849 2.05 / 440.65 1 1
3 13 1600.00 22 14.39 2515 796 2.85 / 441.44 1 1
4 13 1046.92 22 14.55 1777 569 3.42 / 442.01 1 1
5 13 469.40 22 14.79 1027 334 3.75 / 442.35 1 1
6 13 79.76 22 15.01 469 155 3.91 / 442.50 1 1
7 8 0.16 165 15.01 339 840 4.75 / 443.34 1 4
Average= 4.57
(KJ/cycle)

Cycle 95 GMT 10/ 5/2020 11:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.76 27 15.01 500 203 0.20 / 434.37 1 1
2 7 2004.72 43 14.27 2996 1838 2.04 / 436.20 1 1
3 13 1487.20 22 14.43 2353 747 2.79 / 436.95 1 1
4 13 1081.24 22 14.54 1820 582 3.37 / 437.53 1 1
5 13 251.52 22 14.93 713 234 3.60 / 437.77 1 1
6 8 0.12 165 15.03 333 826 4.43 / 438.59 1 2
Average= 4.57
(KJ/cycle)

Cycle 94 GMT 30/ 4/2020 11:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.76 27 15.01 494 200 0.20 / 429.61 1 1
2 7 2007.16 43 14.26 3028 1857 2.06 / 431.46 1 1
3 13 1885.12 22 14.30 2896 911 2.97 / 432.37 1 1
4 13 883.32 22 14.63 1565 504 3.47 / 432.88 1 1
5 13 470.88 22 14.80 1027 334 3.81 / 433.21 1 1
6 13 18.52 22 15.06 363 120 3.93 / 433.33 1 1
7 8 0.20 165 15.03 335 831 4.76 / 434.16 1 1
Average= 4.57
(KJ/cycle)

Cycle 93 GMT 20/ 4/2020 11:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.00 27 15.01 498 202 0.20 / 424.87 1 1
2 7 2009.92 43 14.25 3001 1839 2.04 / 426.71 1 1
3 13 1889.04 22 14.30 2869 903 2.94 / 427.62 1 1
4 13 1028.04 22 14.57 1756 563 3.51 / 428.18 1 1
5 13 343.96 22 14.87 851 278 3.78 / 428.46 1 1
6 13 46.04 22 15.05 394 130 3.91 / 428.59 1 1
7 8 0.04 165 15.03 330 818 4.73 / 429.41 1 1
Average= 4.57
(KJ/cycle)

Cycle 92 GMT 10/ 4/2020 10:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.16 27 15.01 499 202 0.20 / 420.25 1 1
2 7 2007.16 43 14.26 3021 1852 2.05 / 422.10 1 1
3 13 1609.48 22 14.39 2500 791 2.85 / 422.89 1 1
4 13 1039.72 22 14.57 1743 559 3.40 / 423.45 1 1
5 13 321.16 22 14.89 811 266 3.67 / 423.72 1 1
6 13 37.68 22 15.05 395 131 3.80 / 423.85 1 1
7 8 0.00 165 15.03 332 823 4.62 / 424.67 1 2
Average= 4.57
(KJ/cycle)

Cycle 91 GMT 31/ 3/2020 10:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.08 27 15.01 500 203 0.20 / 415.46 1 1
2 7 2008.68 43 14.26 3014 1848 2.05 / 417.30 1 1
3 13 1882.60 22 14.30 2897 911 2.96 / 418.21 1 1
4 13 1006.76 22 14.58 1734 556 3.52 / 418.77 1 1
5 13 428.16 22 14.82 971 317 3.83 / 419.09 1 1
6 13 63.84 22 15.04 438 145 3.98 / 419.23 1 1
7 8 0.08 165 15.03 329 816 4.80 / 420.05 1 2
Average= 4.57
(KJ/cycle)

Cycle 90 GMT 21/ 3/2020 10:57: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.68 27 15.02 488 198 0.20 / 410.74 1 1
2 7 2005.08 43 14.26 3027 1856 2.05 / 412.59 1 1
3 13 1740.24 22 14.34 2699 851 2.91 / 413.45 1 1
4 13 1007.72 22 14.58 1705 547 3.45 / 413.99 1 1
5 13 425.92 22 14.83 943 308 3.76 / 414.30 1 1
6 13 31.52 22 15.06 382 127 3.89 / 414.43 1 1
7 8 0.08 165 15.03 333 826 4.71 / 415.25 1 2
Average= 4.56
(KJ/cycle)

Cycle 89 GMT 11/ 3/2020 10:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.08 27 15.02 488 198 0.20 / 405.99 1 1
2 7 2003.72 43 14.27 2998 1840 2.04 / 407.83 1 1
3 13 1732.16 22 14.35 2676 845 2.88 / 408.68 1 1
4 13 1154.96 22 14.52 1910 610 3.49 / 409.29 1 1
5 13 421.52 22 14.82 965 315 3.81 / 409.60 1 1
6 13 32.20 22 15.06 379 126 3.93 / 409.73 1 1
7 8 0.08 165 15.03 328 813 4.75 / 410.54 1 2
Average= 4.56
(KJ/cycle)

Cycle 88 GMT 1/ 3/2020 11: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.60 27 15.02 487 197 0.20 / 401.42 1 1
2 7 2004.32 43 14.25 3037 1861 2.06 / 403.29 1 1
3 13 1499.32 22 14.42 2379 755 2.81 / 404.04 1 1
4 13 946.72 22 14.60 1652 531 3.34 / 404.57 1 1
5 13 368.60 22 14.86 891 291 3.64 / 404.86 1 1
6 13 24.60 22 15.06 364 121 3.76 / 404.98 1 1
7 8 0.04 165 15.03 327 811 4.57 / 405.79 1 2
Average= 4.56
(KJ/cycle)

Cycle 87 GMT 20/ 2/2020 10:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.16 27 15.02 479 194 0.19 / 396.64 1 1
2 7 2007.16 43 14.26 3020 1852 2.05 / 398.49 1 1
3 13 1877.08 22 14.31 2877 906 2.95 / 399.40 1 1
4 13 1001.40 22 14.59 1693 543 3.50 / 399.94 1 1
5 13 566.40 22 14.77 1117 363 3.86 / 400.30 1 1
6 13 55.12 22 15.05 405 134 3.99 / 400.44 1 1
7 8 0.00 165 15.03 319 791 4.78 / 401.23 1 1
Average= 4.56
(KJ/cycle)

Cycle 86 GMT 10/ 2/2020 10:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.44 27 15.02 500 203 0.20 / 391.92 1 1
2 7 2002.84 43 14.26 3029 1857 2.06 / 393.78 1 1
3 13 1726.00 22 14.36 2667 843 2.90 / 394.62 1 1
4 13 1015.88 22 14.57 1737 557 3.46 / 395.18 1 1
5 13 452.04 22 14.82 1005 328 3.79 / 395.51 1 1
6 13 36.20 22 15.06 389 129 3.92 / 395.64 1 1
7 8 0.08 165 15.03 325 806 4.72 / 396.44 1 3
Average= 4.56
(KJ/cycle)

Cycle 85 GMT 31/ 1/2020 11:10: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.88 27 15.02 499 202 0.20 / 387.42 1 1
2 7 2003.32 43 14.25 3013 1846 2.05 / 389.27 1 1
3 13 1610.00 22 14.39 2510 795 2.84 / 390.06 1 1
4 13 1038.84 22 14.56 1774 568 3.41 / 390.63 1 1
5 13 337.12 22 14.88 849 278 3.69 / 390.91 1 1
6 8 0.08 165 15.04 328 814 4.50 / 391.72 1 2
Average= 4.55
(KJ/cycle)

Cycle 84 GMT 21/ 1/2020 10:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.88 27 15.03 491 199 0.20 / 382.83 1 1
2 7 2003.04 43 14.28 3004 1845 2.04 / 384.67 1 1
3 13 1745.44 22 14.35 2706 854 2.90 / 385.53 1 1
4 13 1023.12 22 14.57 1735 556 3.45 / 386.08 1 1
5 13 456.64 22 14.81 1009 329 3.78 / 386.41 1 1
6 8 0.08 165 15.04 325 807 4.59 / 387.22 1 2
Average= 4.56
(KJ/cycle)

Cycle 83 GMT 11/ 1/2020 10:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.80 27 15.02 487 197 0.20 / 378.24 1 1
2 7 2006.80 44 14.26 2999 1882 2.08 / 380.12 1 1
3 13 1876.16 22 14.30 2858 899 2.98 / 381.02 1 1
4 13 1008.20 22 14.59 1713 550 3.53 / 381.57 1 1
5 13 315.00 22 14.90 802 263 3.79 / 381.83 1 1
6 8 0.04 165 15.05 322 800 4.59 / 382.63 1 2
Average= 4.56
(KJ/cycle)

Cycle 82 GMT 1/ 1/2020 10:41: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.48 27 15.02 483 196 0.20 / 373.79 1 1
2 7 2001.92 43 14.27 2998 1840 2.04 / 375.63 1 1
3 13 1605.72 22 14.40 2499 792 2.83 / 376.42 1 1
4 13 918.16 22 14.62 1603 516 3.34 / 376.94 1 1
5 13 359.80 22 14.87 870 285 3.63 / 377.22 1 1
6 8 0.04 165 15.04 329 816 4.44 / 378.04 1 2
Average= 4.55
(KJ/cycle)

Cycle 81 GMT 22/12/2019 10:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.00 27 15.02 495 201 0.20 / 369.25 1 1
2 7 2007.44 43 14.27 3008 1846 2.05 / 371.10 1 1
3 13 1592.04 22 14.41 2481 787 2.83 / 371.88 1 1
4 13 1033.00 22 14.58 1743 559 3.39 / 372.44 1 1
5 13 331.16 22 14.89 801 262 3.65 / 372.70 1 1
6 13 41.60 22 15.06 362 120 3.77 / 372.82 1 1
7 8 0.00 165 15.04 311 772 4.55 / 373.59 1 2
Average= 4.56
(KJ/cycle)

Cycle 80 GMT 12/12/2019 10:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.24 27 15.02 497 202 0.20 / 364.65 1 1
2 7 2002.96 43 14.27 3007 1845 2.05 / 366.50 1 1
3 13 1604.08 22 14.40 2507 794 2.84 / 367.29 1 1
4 13 1163.40 22 14.52 1916 612 3.45 / 367.90 1 2
5 13 426.80 22 14.83 959 313 3.77 / 368.21 1 1
6 8 0.08 165 15.04 336 834 4.60 / 369.05 1 2
Average= 4.56
(KJ/cycle)

Cycle 79 GMT 2/12/2019 10:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.16 27 15.02 491 199 0.20 / 359.99 1 1
2 7 2002.20 43 14.28 3003 1844 2.04 / 361.83 1 1
3 13 1728.28 22 14.36 2684 848 2.89 / 362.68 1 1
4 13 1011.12 22 14.59 1719 552 3.44 / 363.23 1 1
5 13 331.92 22 14.89 833 273 3.72 / 363.50 1 1
6 13 18.68 22 15.07 364 121 3.84 / 363.62 1 1
7 8 0.08 165 15.04 332 824 4.66 / 364.45 1 2
Average= 4.56
(KJ/cycle)

Cycle 78 GMT 22/11/2019 10:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.20 26 15.02 477 186 0.19 / 355.42 1 1
2 7 2002.88 43 14.27 3015 1850 2.04 / 357.27 1 1
3 13 1593.88 22 14.40 2506 794 2.83 / 358.07 1 1
4 13 1026.08 22 14.58 1759 564 3.39 / 358.63 1 1
5 13 456.56 22 14.82 1010 329 3.72 / 358.96 1 1
6 8 0.04 165 15.04 334 829 4.55 / 359.79 1 5
Average= 4.55
(KJ/cycle)

Cycle 77 GMT 12/11/2019 10:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.08 27 15.03 497 202 0.20 / 350.85 1 1
2 7 2002.12 43 14.28 3009 1848 2.05 / 352.69 1 1
3 13 1600.20 22 14.42 2498 792 2.84 / 353.49 1 1
4 13 1180.00 22 14.52 1935 618 3.46 / 354.10 1 1
5 13 445.04 22 14.84 967 316 3.78 / 354.42 1 1
6 8 0.08 165 15.05 329 817 4.59 / 355.24 1 1
Average= 4.55
(KJ/cycle)

Cycle 76 GMT 2/11/2019 10:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.92 27 15.02 506 205 0.21 / 346.30 1 1
2 7 2003.64 43 14.27 3018 1852 2.06 / 348.15 1 1
3 13 1735.44 22 14.38 2677 847 2.90 / 349.00 1 1
4 13 1020.76 22 14.59 1739 558 3.46 / 349.56 1 1
5 13 335.04 22 14.89 832 273 3.73 / 349.83 1 1
6 8 0.12 165 15.05 328 815 4.55 / 350.64 1 2
Average= 4.55
(KJ/cycle)

Cycle 75 GMT 23/10/2019 10:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.80 27 15.03 500 203 0.20 / 341.70 1 1
2 7 2004.12 43 14.28 3019 1854 2.06 / 343.55 1 1
3 13 1737.12 22 14.37 2707 856 2.91 / 344.41 1 1
4 13 996.48 22 14.60 1730 556 3.47 / 344.96 1 1
5 13 414.52 22 14.85 959 313 3.78 / 345.28 1 1
6 8 0.08 165 15.05 329 817 4.60 / 346.09 1 3
Average= 4.55
(KJ/cycle)

Cycle 74 GMT 13/10/2019 10:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.52 27 15.02 513 208 0.21 / 337.18 1 1
2 7 2003.76 43 14.28 3010 1848 2.06 / 339.03 1 1
3 13 1603.28 22 14.42 2496 792 2.85 / 339.82 1 1
4 13 1037.96 22 14.59 1766 567 3.41 / 340.39 1 1
5 13 332.84 22 14.90 839 275 3.69 / 340.66 1 1
6 8 0.04 165 15.06 335 832 4.52 / 341.50 1 2
Average= 4.55
(KJ/cycle)

Cycle 73 GMT 3/10/2019 10:31:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.20 26 15.03 500 195 0.20 / 332.51 1 1
2 7 2001.96 43 14.29 3009 1849 2.04 / 334.36 1 1
3 13 1602.24 22 14.42 2524 801 2.85 / 335.16 1 1
4 13 1055.84 22 14.58 1794 575 3.42 / 335.74 1 1
5 13 335.44 22 14.90 844 277 3.70 / 336.01 1 1
6 13 21.24 22 15.08 371 123 3.82 / 336.14 1 1
7 8 0.08 165 15.05 337 837 4.66 / 336.97 1 2
Average= 4.55
(KJ/cycle)

Cycle 72 GMT 23/ 9/2019 10:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.28 27 15.03 501 203 0.20 / 327.98 1 1
2 7 2006.28 44 14.29 3019 1898 2.10 / 329.88 1 1
3 13 1626.16 22 14.42 2524 801 2.90 / 330.68 1 1
4 13 933.96 22 14.64 1621 522 3.42 / 331.21 1 1
5 13 359.44 22 14.89 871 285 3.71 / 331.49 1 1
6 8 0.16 165 15.06 332 825 4.53 / 332.32 1 1
Average= 4.55
(KJ/cycle)

Cycle 71 GMT 13/ 9/2019 10:19:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.72 26 15.05 495 194 0.19 / 323.46 1 1
2 7 2003.40 43 14.29 3015 1853 2.05 / 325.31 1 1
3 13 1604.28 22 14.43 2494 792 2.84 / 326.10 1 1
4 13 1046.40 22 14.60 1762 566 3.40 / 326.67 1 1
5 13 334.36 22 14.91 841 276 3.68 / 326.94 1 1
6 8 0.20 165 15.06 338 840 4.52 / 327.78 1 2
Average= 4.55
(KJ/cycle)

Cycle 70 GMT 3/ 9/2019 10:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.44 26 15.04 502 196 0.20 / 318.95 1 1
2 7 2005.00 43 14.30 3023 1859 2.06 / 320.81 1 1
3 13 1603.40 22 14.43 2499 793 2.85 / 321.60 1 1
4 13 1029.60 22 14.61 1760 566 3.41 / 322.17 1 1
5 13 318.84 22 14.92 821 269 3.68 / 322.44 1 1
6 8 0.12 165 15.07 331 823 4.51 / 323.26 1 2
Average= 4.55
(KJ/cycle)

Cycle 69 GMT 24/ 8/2019 10:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.96 26 15.04 506 198 0.20 / 314.38 1 1
2 7 2004.08 43 14.30 3018 1856 2.05 / 316.23 1 1
3 13 1609.52 22 14.44 2523 802 2.86 / 317.03 1 1
4 13 1050.72 22 14.60 1766 567 3.42 / 317.60 1 1
5 13 472.24 22 14.85 1007 329 3.75 / 317.93 1 1
6 8 0.16 165 15.07 332 826 4.58 / 318.76 1 2
Average= 4.55
(KJ/cycle)

Cycle 68 GMT 14/ 8/2019 10:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.72 26 15.05 507 198 0.20 / 309.77 1 1
2 7 2004.48 43 14.30 2993 1840 2.04 / 311.61 1 1
3 13 1731.84 22 14.40 2679 849 2.89 / 312.46 1 1
4 13 1022.44 22 14.62 1734 558 3.45 / 313.02 1 1
5 13 439.56 22 14.86 985 322 3.77 / 313.34 1 1
6 8 0.00 165 15.07 338 840 4.61 / 314.18 1 2
Average= 4.55
(KJ/cycle)

Cycle 67 GMT 4/ 8/2019 10:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.72 26 15.06 499 195 0.20 / 305.30 1 1
2 7 2003.44 43 14.30 3029 1863 2.06 / 307.16 1 1
3 13 1606.44 22 14.45 2497 794 2.85 / 307.95 1 1
4 13 921.76 22 14.67 1593 514 3.37 / 308.47 1 1
5 13 359.84 22 14.91 869 285 3.65 / 308.75 1 1
6 8 0.12 165 15.08 329 819 4.47 / 309.57 1 2
Average= 4.55
(KJ/cycle)

Cycle 66 GMT 25/ 7/2019 10:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.44 26 15.05 507 198 0.20 / 300.75 1 1
2 7 2003.00 43 14.31 3022 1860 2.06 / 302.61 1 1
3 13 1730.20 22 14.40 2688 852 2.91 / 303.46 1 1
4 13 1028.60 22 14.63 1723 555 3.46 / 304.02 1 1
5 13 321.16 22 14.94 813 267 3.73 / 304.28 1 1
6 8 0.04 165 15.08 329 819 4.55 / 305.10 1 2
Average= 4.55
(KJ/cycle)

Cycle 65 GMT 15/ 7/2019 10: 7: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.24 26 15.06 512 200 0.20 / 296.13 1 1
2 7 2005.24 43 14.31 3018 1857 2.06 / 297.99 1 1
3 13 1605.12 22 14.46 2500 795 2.85 / 298.78 1 1
4 13 928.92 22 14.67 1619 523 3.38 / 299.30 1 1
5 13 372.44 22 14.91 896 294 3.67 / 299.60 1 1
6 13 49.76 22 15.10 404 134 3.80 / 299.73 1 1
7 8 0.04 165 15.07 329 818 4.62 / 300.55 1 2
Average= 4.55
(KJ/cycle)

Cycle 64 GMT 5/ 7/2019 9:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.64 26 15.05 505 198 0.20 / 291.63 1 1
2 7 2005.48 43 14.31 3027 1863 2.06 / 293.49 1 1
3 13 1601.52 22 14.45 2543 808 2.87 / 294.30 1 1
4 13 900.64 22 14.68 1584 512 3.38 / 294.81 1 1
5 13 339.32 22 14.93 857 281 3.66 / 295.09 1 1
6 8 0.04 165 15.08 337 839 4.50 / 295.93 1 2
Average= 4.55
(KJ/cycle)

Cycle 63 GMT 25/ 6/2019 9:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.92 26 15.06 510 200 0.20 / 286.88 1 1
2 7 2003.16 43 14.32 3006 1851 2.05 / 288.73 1 1
3 13 1726.64 22 14.42 2660 844 2.89 / 289.58 1 1
4 13 1016.40 22 14.63 1752 564 3.46 / 290.14 1 1
5 13 419.04 22 14.89 965 316 3.77 / 290.46 1 1
6 13 34.76 22 15.11 390 130 3.90 / 290.59 1 1
7 8 0.28 165 15.08 339 843 4.75 / 291.43 1 2
Average= 4.55
(KJ/cycle)

Cycle 62 GMT 15/ 6/2019 9:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.60 26 15.07 502 197 0.20 / 282.19 1 1
2 7 2003.48 43 14.31 3018 1857 2.05 / 284.05 1 1
3 13 1740.28 22 14.41 2688 852 2.91 / 284.90 1 1
4 13 1015.96 22 14.65 1719 554 3.46 / 285.45 1 1
5 13 312.88 22 14.95 806 265 3.73 / 285.72 1 1
6 13 41.36 22 15.11 397 132 3.86 / 285.85 1 1
7 8 0.12 165 15.08 334 831 4.69 / 286.68 1 2
Average= 4.55
(KJ/cycle)

Cycle 61 GMT 5/ 6/2019 9:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.48 26 15.09 469 184 0.18 / 277.66 1 1
2 7 2003.96 43 14.32 3017 1858 2.04 / 279.52 1 1
3 13 1593.12 22 14.47 2497 795 2.84 / 280.32 1 1
4 13 1033.64 22 14.65 1734 559 3.40 / 280.88 1 1
5 13 439.56 22 14.90 949 311 3.71 / 281.19 1 1
6 8 0.12 165 15.10 324 807 4.51 / 281.99 1 1
Average= 4.55
(KJ/cycle)

Cycle 60 GMT 26/ 5/2019 9:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.36 26 15.09 496 195 0.19 / 273.17 1 1
2 7 2002.28 43 14.33 3022 1862 2.06 / 275.03 1 1
3 13 1597.00 22 14.48 2506 798 2.86 / 275.83 1 1
4 13 1036.12 22 14.64 1764 568 3.42 / 276.40 1 1
5 13 338.92 22 14.95 840 276 3.70 / 276.67 1 1
6 8 0.12 165 15.11 324 808 4.51 / 277.48 1 2
Average= 4.55
(KJ/cycle)

Cycle 59 GMT 16/ 5/2019 9:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.28 26 15.09 492 193 0.19 / 268.69 1 1
2 7 2010.64 43 14.33 3038 1872 2.07 / 270.56 1 1
3 13 1603.52 22 14.48 2502 797 2.86 / 271.36 1 1
4 13 1013.44 22 14.66 1724 556 3.42 / 271.92 1 1
5 13 303.88 22 14.98 769 253 3.67 / 272.17 1 1
6 8 0.08 165 15.11 322 803 4.47 / 272.97 1 1
Average= 4.55
(KJ/cycle)

Cycle 58 GMT 6/ 5/2019 8:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.12 26 15.09 498 195 0.20 / 263.92 1 1
2 7 2004.80 43 14.34 3011 1857 2.05 / 265.77 1 1
3 13 1873.12 22 14.40 2865 908 2.96 / 266.68 1 1
4 13 1002.72 22 14.67 1714 553 3.51 / 267.23 1 1
5 13 424.16 22 14.91 957 314 3.83 / 267.55 1 1
6 13 63.56 22 15.11 428 142 3.97 / 267.69 1 1
7 8 0.08 165 15.10 324 807 4.78 / 268.50 1 3
Average= 4.55
(KJ/cycle)

Cycle 57 GMT 26/ 4/2019 8:57: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.28 26 15.09 507 199 0.20 / 259.18 1 1
2 7 2003.56 44 14.34 3009 1899 2.10 / 261.08 1 1
3 13 1742.60 22 14.43 2710 860 2.96 / 261.94 1 1
4 13 1281.68 22 14.54 2106 674 3.63 / 262.61 1 1
5 13 380.68 22 14.93 912 300 3.93 / 262.91 1 1
6 8 0.20 165 15.11 325 810 4.74 / 263.72 1 1
Average= 4.55
(KJ/cycle)

Cycle 56 GMT 16/ 4/2019 8:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.48 26 15.11 496 195 0.19 / 254.56 1 1
2 7 2003.36 43 14.33 3034 1870 2.06 / 256.43 1 1
3 13 1733.48 22 14.44 2698 857 2.92 / 257.29 1 1
4 13 1024.44 22 14.66 1753 565 3.49 / 257.85 1 1
5 13 426.24 22 14.91 973 319 3.81 / 258.17 1 1
6 8 0.08 165 15.11 325 810 4.62 / 258.98 1 2
Average= 4.54
(KJ/cycle)

Cycle 55 GMT 6/ 4/2019 9: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.52 26 15.10 502 197 0.20 / 250.03 1 1
2 7 2006.32 43 14.34 3014 1858 2.06 / 251.89 1 1
3 13 1604.48 22 14.47 2558 814 2.87 / 252.70 1 1
4 13 1036.96 22 14.66 1782 575 3.44 / 253.28 1 1
5 13 343.92 22 14.96 855 281 3.73 / 253.56 1 1
6 8 0.08 165 15.12 322 803 4.53 / 254.36 1 1
Average= 4.54
(KJ/cycle)

Cycle 54 GMT 27/ 3/2019 8:55: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.44 26 15.09 497 195 0.19 / 245.37 1 1
2 7 2008.44 43 14.34 3030 1868 2.06 / 247.24 1 1
3 13 1746.68 22 14.43 2724 865 2.93 / 248.11 1 1
4 13 1028.28 22 14.66 1778 573 3.50 / 248.68 1 1
5 13 447.64 22 14.90 1000 328 3.83 / 249.01 1 1
6 8 0.08 165 15.12 332 828 4.66 / 249.84 1 2
Average= 4.54
(KJ/cycle)

Cycle 53 GMT 17/ 3/2019 8:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.24 26 15.10 501 197 0.20 / 240.56 1 1
2 7 2002.72 43 14.35 3016 1861 2.06 / 242.42 1 1
3 13 1737.12 22 14.44 2686 853 2.91 / 243.27 1 1
4 13 1276.72 22 14.57 2069 663 3.57 / 243.93 1 1
5 13 370.28 22 14.95 892 293 3.87 / 244.23 1 1
6 13 25.00 22 15.15 362 121 3.99 / 244.35 1 1
7 8 0.08 165 15.11 333 830 4.82 / 245.18 1 1
Average= 4.54
(KJ/cycle)

Cycle 52 GMT 7/ 3/2019 8:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.44 26 15.11 499 196 0.20 / 235.94 1 1
2 7 2003.76 43 14.35 3009 1857 2.05 / 237.79 1 1
3 13 1594.88 22 14.50 2484 792 2.85 / 238.59 1 1
4 13 1036.92 22 14.67 1755 566 3.41 / 239.15 1 1
5 13 330.04 22 14.98 830 274 3.69 / 239.43 1 1
6 13 39.60 22 15.14 391 130 3.82 / 239.56 1 1
7 8 0.04 165 15.12 322 803 4.62 / 240.36 1 2
Average= 4.54
(KJ/cycle)

Cycle 51 GMT 25/ 2/2019 8:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.36 26 15.09 502 197 0.20 / 231.30 1 1
2 7 2005.60 43 14.35 3017 1862 2.06 / 233.16 1 1
3 13 1740.68 22 14.45 2698 858 2.92 / 234.02 1 1
4 13 1136.00 22 14.64 1878 605 3.52 / 234.62 1 1
5 13 402.72 22 14.95 910 299 3.82 / 234.92 1 1
6 8 0.16 165 15.13 327 816 4.64 / 235.74 1 2
Average= 4.53
(KJ/cycle)

Cycle 50 GMT 15/ 2/2019 8:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.16 26 15.12 485 191 0.19 / 226.55 1 1
2 7 2002.80 44 14.35 3025 1910 2.10 / 228.46 1 1
3 13 1723.16 22 14.45 2681 852 2.95 / 229.31 1 1
4 13 999.32 22 14.69 1706 551 3.50 / 229.86 1 1
5 13 413.08 22 14.94 919 302 3.81 / 230.16 1 1
6 13 53.36 22 15.14 387 129 3.94 / 230.29 1 1
7 8 0.00 165 15.12 326 813 4.75 / 231.10 1 2
Average= 4.53
(KJ/cycle)

Cycle 49 GMT 5/ 2/2019 8:39: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.72 26 15.11 494 194 0.19 / 222.08 1 1
2 7 2002.00 43 14.36 3021 1865 2.06 / 223.95 1 1
3 13 1475.40 22 14.54 2348 751 2.81 / 224.70 1 1
4 13 950.52 22 14.71 1653 535 3.35 / 225.24 1 1
5 13 374.16 22 14.95 897 295 3.64 / 225.53 1 1
6 8 0.04 165 15.13 330 824 4.46 / 226.35 1 1
Average= 4.53
(KJ/cycle)

Cycle 48 GMT 26/ 1/2019 8:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.44 26 15.11 514 202 0.20 / 217.51 1 1
2 7 2006.28 43 14.36 3025 1868 2.07 / 219.37 1 1
3 13 1611.24 22 14.50 2510 801 2.87 / 220.17 1 1
4 13 1176.12 22 14.62 1970 634 3.50 / 220.81 1 1
5 13 305.52 22 15.00 800 264 3.77 / 221.07 1 1
6 8 0.12 165 15.14 328 819 4.59 / 221.89 1 1
Average= 4.53
(KJ/cycle)

Cycle 47 GMT 16/ 1/2019 8:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.68 26 15.11 507 199 0.20 / 212.98 1 1
2 7 2002.72 44 14.36 3017 1906 2.11 / 214.88 1 1
3 13 1591.08 22 14.49 2509 800 2.91 / 215.68 1 1
4 13 878.60 22 14.75 1538 499 3.40 / 216.18 1 1
5 13 308.72 22 15.00 788 260 3.66 / 216.44 1 1
6 8 -0.04 165 15.13 345 861 4.53 / 217.30 1 2
Average= 4.53
(KJ/cycle)

Cycle 46 GMT 6/ 1/2019 8:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.68 26 15.11 503 198 0.20 / 208.46 1 1
2 7 2003.92 44 14.36 3029 1914 2.11 / 210.37 1 1
3 13 1464.60 22 14.55 2316 741 2.85 / 211.11 1 1
4 13 1031.24 22 14.68 1752 566 3.42 / 211.68 1 1
5 13 299.32 22 15.01 767 253 3.67 / 211.93 1 1
6 8 0.16 165 15.13 338 844 4.52 / 212.78 1 5
Average= 4.53
(KJ/cycle)

Cycle 45 GMT 27/12/2018 8: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.76 26 15.12 493 194 0.19 / 203.94 1 1
2 7 2002.28 43 14.36 3050 1883 2.08 / 205.83 1 1
3 13 1576.36 22 14.51 2509 801 2.88 / 206.63 1 1
4 13 876.96 22 14.75 1570 509 3.39 / 207.14 1 1
5 13 326.64 22 14.99 838 276 3.66 / 207.41 1 1
6 8 0.00 165 15.14 340 849 4.51 / 208.26 1 1
Average= 4.53
(KJ/cycle)

Cycle 44 GMT 17/12/2018 7:42:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.36 26 15.12 494 194 0.19 / 199.45 1 1
2 7 2004.84 43 14.37 3027 1870 2.06 / 201.32 1 1
3 13 1615.76 22 14.51 2525 806 2.87 / 202.12 1 1
4 13 907.48 22 14.75 1576 511 3.38 / 202.63 1 2
5 13 334.64 22 15.00 818 270 3.65 / 202.90 1 1
6 8 0.12 165 15.14 338 844 4.50 / 203.75 1 1
Average= 4.53
(KJ/cycle)

Cycle 43 GMT 7/12/2018 7:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.00 26 15.12 503 198 0.20 / 194.81 1 1
2 7 2002.76 43 14.37 3021 1867 2.06 / 196.67 1 1
3 13 1729.52 22 14.47 2682 854 2.92 / 197.53 1 1
4 13 1019.40 22 14.71 1732 561 3.48 / 198.09 1 1
5 13 426.96 22 14.94 973 320 3.80 / 198.41 1 1
6 8 0.16 165 15.14 338 844 4.64 / 199.25 1 2
Average= 4.53
(KJ/cycle)

Cycle 42 GMT 27/11/2018 7:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.68 26 15.12 494 194 0.19 / 190.33 1 1
2 7 2006.16 43 14.37 3025 1869 2.06 / 192.20 1 1
3 13 1482.04 22 14.55 2352 753 2.82 / 192.95 1 1
4 13 926.96 22 14.74 1618 525 3.34 / 193.48 1 1
5 13 360.24 22 14.98 863 284 3.63 / 193.76 1 1
6 8 0.12 165 15.14 339 847 4.47 / 194.61 1 1
Average= 4.53
(KJ/cycle)

Cycle 41 GMT 17/11/2018 6:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.56 26 15.12 501 197 0.20 / 185.60 1 1
2 7 2003.84 43 14.38 3031 1874 2.07 / 187.47 1 1
3 13 1596.20 22 14.52 2483 793 2.86 / 188.27 1 1
4 13 1024.20 22 14.70 1752 567 3.43 / 188.83 1 1
5 13 435.84 22 14.94 982 323 3.75 / 189.15 1 1
6 13 28.28 22 15.17 377 126 3.88 / 189.28 1 1
7 8 0.12 165 15.14 343 857 4.74 / 190.14 1 3
Average= 4.53
(KJ/cycle)

Cycle 40 GMT 7/11/2018 6:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.52 26 15.13 497 196 0.20 / 181.00 1 1
2 7 2003.20 43 14.38 3023 1869 2.06 / 182.87 1 1
3 13 1730.12 22 14.48 2670 851 2.92 / 183.72 1 1
4 13 1015.80 22 14.72 1718 556 3.47 / 184.28 1 1
5 13 304.00 22 15.02 794 262 3.73 / 184.54 1 1
6 8 0.08 165 15.15 343 857 4.59 / 185.40 1 2
Average= 4.52
(KJ/cycle)

Cycle 39 GMT 28/10/2018 6:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.60 26 15.13 513 202 0.20 / 176.50 1 1
2 7 2003.76 43 14.39 3016 1866 2.07 / 178.37 1 1
3 13 1597.28 22 14.53 2506 801 2.87 / 179.17 1 1
4 13 909.08 22 14.76 1606 522 3.39 / 179.69 1 1
5 13 343.72 22 15.01 859 284 3.67 / 179.97 1 1
6 8 0.04 165 15.16 335 838 4.51 / 180.81 1 2
Average= 4.52
(KJ/cycle)

Cycle 38 GMT 18/10/2018 6: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.44 26 15.13 504 198 0.20 / 171.89 1 1
2 7 2003.84 43 14.39 3015 1866 2.06 / 173.76 1 1
3 13 1732.76 22 14.49 2662 849 2.91 / 174.61 1 1
4 13 989.48 22 14.73 1708 553 3.47 / 175.16 1 1
5 13 399.36 22 14.98 917 302 3.77 / 175.46 1 1
6 8 0.04 165 15.16 334 835 4.60 / 176.30 1 2
Average= 4.52
(KJ/cycle)

Cycle 37 GMT 8/10/2018 5:57: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.56 26 15.13 507 199 0.20 / 167.20 1 1
2 7 2001.96 43 14.39 3019 1868 2.07 / 169.07 1 1
3 13 1723.36 22 14.49 2682 855 2.92 / 169.93 1 1
4 13 1123.88 22 14.67 1890 610 3.53 / 170.54 1 1
5 13 384.32 22 14.98 922 304 3.84 / 170.84 1 1
6 8 0.24 165 15.16 341 853 4.69 / 171.69 1 2
Average= 4.52
(KJ/cycle)

Cycle 36 GMT 28/ 9/2018 5:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.20 26 15.14 510 201 0.20 / 162.56 1 1
2 7 2003.12 44 14.39 3036 1922 2.12 / 164.49 1 1
3 13 1738.52 22 14.48 2698 859 2.98 / 165.35 1 1
4 13 1006.88 22 14.72 1724 558 3.54 / 165.90 1 1
5 13 285.00 22 15.05 753 249 3.79 / 166.15 1 1
6 8 0.00 165 15.16 340 850 4.64 / 167.00 1 2
Average= 4.51
(KJ/cycle)

Cycle 35 GMT 18/ 9/2018 5:50: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.92 26 15.13 511 201 0.20 / 158.05 1 1
2 7 2003.60 43 14.39 3036 1879 2.08 / 159.93 1 1
3 13 1475.32 22 14.57 2361 757 2.84 / 160.68 1 1
4 13 926.40 22 14.75 1637 531 3.37 / 161.21 1 1
5 13 351.08 22 15.00 879 290 3.66 / 161.50 1 1
6 8 0.04 165 15.16 344 860 4.52 / 162.36 1 1
Average= 4.51
(KJ/cycle)

Cycle 34 GMT 8/ 9/2018 5:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.08 26 15.14 497 196 0.20 / 153.45 1 1
2 7 2001.08 43 14.41 3028 1876 2.07 / 155.33 1 1
3 13 1594.72 22 14.53 2534 810 2.88 / 156.14 1 1
4 13 1030.52 22 14.72 1773 574 3.46 / 156.71 1 1
5 13 316.68 22 15.03 813 269 3.72 / 156.98 1 1
6 8 0.08 165 15.16 346 865 4.59 / 157.85 1 2
Average= 4.51
(KJ/cycle)

Cycle 33 GMT 29/ 8/2018 5:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.20 26 15.13 513 202 0.20 / 148.85 1 1
2 7 2004.12 43 14.41 3019 1871 2.07 / 150.72 1 1
3 13 1616.24 22 14.54 2538 812 2.88 / 151.53 1 1
4 13 1154.72 22 14.66 1940 626 3.51 / 152.15 1 1
5 13 295.20 22 15.05 793 263 3.77 / 152.42 1 1
6 8 0.12 165 15.17 335 839 4.61 / 153.26 1 1
Average= 4.51
(KJ/cycle)

Cycle 32 GMT 19/ 8/2018 5: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.76 25 15.14 502 190 0.19 / 144.17 1 1
2 7 2006.28 43 14.41 3037 1882 2.07 / 146.06 1 1
3 13 1597.24 22 14.54 2527 808 2.88 / 146.86 1 1
4 13 1034.08 22 14.72 1776 575 3.46 / 147.44 1 1
5 13 441.88 22 14.96 1009 332 3.79 / 147.77 1 1
6 8 0.16 165 15.16 349 873 4.66 / 148.64 1 1
Average= 4.50
(KJ/cycle)

Cycle 31 GMT 9/ 8/2018 4:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.92 25 15.15 506 192 0.19 / 139.56 1 1
2 7 2001.92 44 14.41 3035 1924 2.12 / 141.48 1 1
3 13 1581.24 22 14.55 2506 802 2.92 / 142.28 1 1
4 13 1016.12 22 14.73 1756 569 3.49 / 142.85 1 1
5 13 302.56 22 15.04 808 267 3.75 / 143.12 1 1
6 8 0.04 165 15.17 345 864 4.62 / 143.98 1 2
Average= 4.50
(KJ/cycle)

Cycle 30 GMT 30/ 7/2018 4:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 25 15.15 502 190 0.19 / 134.98 1 1
2 7 2001.08 43 14.42 3024 1875 2.07 / 136.85 1 1
3 13 1587.44 22 14.56 2502 801 2.87 / 137.65 1 1
4 13 1036.64 22 14.73 1769 573 3.44 / 138.23 1 1
5 13 306.00 22 15.04 808 267 3.71 / 138.49 1 1
6 8 -0.04 165 15.17 348 871 4.58 / 139.37 1 2
Average= 4.50
(KJ/cycle)

Cycle 29 GMT 20/ 7/2018 4:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.76 25 15.15 498 189 0.19 / 130.33 1 1
2 7 2002.96 43 14.42 3045 1888 2.08 / 132.21 1 1
3 13 1593.56 22 14.55 2539 813 2.89 / 133.03 1 1
4 13 1019.24 22 14.74 1755 569 3.46 / 133.60 1 1
5 13 421.68 22 14.98 974 321 3.78 / 133.92 1 1
6 8 0.16 165 15.17 348 871 4.65 / 134.79 1 2
Average= 4.49
(KJ/cycle)

Cycle 28 GMT 10/ 7/2018 4: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.32 25 15.17 509 193 0.19 / 125.59 1 1
2 7 2002.76 43 14.42 3030 1879 2.07 / 127.47 1 1
3 13 1730.84 22 14.51 2712 866 2.94 / 128.34 1 1
4 13 1135.24 22 14.69 1909 617 3.55 / 128.96 1 1
5 13 391.96 22 15.00 931 307 3.86 / 129.26 1 1
6 8 0.08 165 15.17 349 874 4.74 / 130.14 1 2
Average= 4.49
(KJ/cycle)

Cycle 27 GMT 30/ 6/2018 3:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.40 25 15.16 497 188 0.19 / 121.09 1 1
2 7 2005.84 43 14.43 3010 1868 2.06 / 122.96 1 1
3 13 1582.72 22 14.57 2511 805 2.86 / 123.76 1 1
4 13 864.52 22 14.80 1558 507 3.37 / 124.27 1 1
5 13 304.72 22 15.05 811 269 3.64 / 124.54 1 1
6 8 0.16 165 15.18 344 862 4.50 / 125.40 1 2
Average= 4.48
(KJ/cycle)

Cycle 26 GMT 20/ 6/2018 3:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.92 25 15.17 510 193 0.19 / 116.44 1 1
2 7 2002.68 43 14.44 3033 1883 2.08 / 118.32 1 1
3 13 1458.84 22 14.62 2322 747 2.82 / 119.07 1 1
4 13 1044.72 22 14.73 1799 583 3.41 / 119.65 1 1
5 13 314.28 22 15.05 819 271 3.68 / 119.92 1 1
6 13 51.04 22 15.20 419 140 3.82 / 120.06 1 1
7 8 -0.04 165 15.18 336 842 4.66 / 120.90 1 3
Average= 4.48
(KJ/cycle)

Cycle 25 GMT 10/ 6/2018 3:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.44 25 15.17 504 191 0.19 / 111.87 1 1
2 7 2004.60 43 14.44 3026 1879 2.07 / 113.75 1 1
3 13 1732.64 22 14.53 2679 856 2.93 / 114.60 1 1
4 13 877.68 22 14.81 1566 510 3.44 / 115.11 1 1
5 13 320.92 22 15.05 827 274 3.71 / 115.39 1 1
6 8 0.12 165 15.19 342 857 4.57 / 116.24 1 3
Average= 4.47
(KJ/cycle)

Cycle 24 GMT 31/ 5/2018 2:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.76 25 15.17 521 198 0.20 / 107.32 1 1
2 7 2003.00 43 14.44 3022 1876 2.07 / 109.20 1 1
3 13 1605.88 22 14.58 2524 810 2.88 / 110.01 1 1
4 13 893.44 22 14.81 1573 513 3.40 / 110.52 1 1
5 13 446.92 22 14.99 984 325 3.72 / 110.85 1 1
6 8 0.00 165 15.19 331 830 4.55 / 111.68 1 3
Average= 4.47
(KJ/cycle)

Cycle 23 GMT 21/ 5/2018 2:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.36 25 15.18 505 192 0.19 / 102.80 1 1
2 7 2004.96 43 14.45 3030 1883 2.07 / 104.68 1 1
3 13 1596.80 22 14.58 2511 805 2.88 / 105.49 1 1
4 13 885.56 22 14.82 1563 510 3.39 / 106.00 1 1
5 13 307.88 22 15.06 808 268 3.66 / 106.26 1 1
6 8 0.08 165 15.19 344 862 4.52 / 107.13 1 2
Average= 4.46
(KJ/cycle)

Cycle 22 GMT 11/ 5/2018 2:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.76 25 15.18 501 190 0.19 / 98.13 1 1
2 7 2004.52 43 14.45 3046 1893 2.08 / 100.02 1 1
3 13 1732.76 22 14.54 2699 863 2.95 / 100.89 1 1
4 13 1138.40 22 14.71 1898 614 3.56 / 101.50 1 1
5 13 269.24 22 15.10 735 244 3.80 / 101.75 1 1
6 8 0.12 165 15.20 343 860 4.66 / 102.61 1 1
Average= 4.46
(KJ/cycle)

Cycle 21 GMT 1/ 5/2018 1:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.92 25 15.18 512 194 0.19 / 93.49 1 1
2 7 2002.44 43 14.46 3039 1890 2.08 / 95.38 1 1
3 13 1614.52 22 14.57 2582 828 2.91 / 96.21 1 1
4 13 1167.88 22 14.70 1956 633 3.54 / 96.84 1 1
5 13 285.64 22 15.08 781 259 3.80 / 97.10 1 1
6 8 0.08 165 15.20 336 843 4.65 / 97.94 1 2
Average= 4.45
(KJ/cycle)

Cycle 20 GMT 21/ 4/2018 1:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.00 25 15.18 505 192 0.19 / 88.86 1 1
2 7 2004.72 43 14.46 3061 1903 2.09 / 90.76 1 1
3 13 1596.76 22 14.59 2552 819 2.91 / 91.58 1 1
4 13 1026.76 22 14.76 1777 577 3.49 / 92.16 1 1
5 13 298.20 22 15.08 808 268 3.76 / 92.43 1 1
6 8 0.12 165 15.20 347 870 4.63 / 93.30 1 2
Average= 4.44
(KJ/cycle)

Cycle 19 GMT 11/ 4/2018 1: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.84 25 15.19 520 197 0.20 / 84.14 1 1
2 7 2003.48 43 14.47 3039 1891 2.09 / 86.03 1 1
3 13 1582.72 22 14.61 2510 807 2.90 / 86.84 1 1
4 13 1001.68 22 14.78 1738 565 3.46 / 87.40 1 1
5 13 303.32 22 15.08 820 272 3.73 / 87.67 1 1
6 13 17.88 22 15.23 378 127 3.86 / 87.80 1 1
7 8 0.08 165 15.20 345 865 4.72 / 88.67 1 2
Average= 4.43
(KJ/cycle)

Cycle 18 GMT 1/ 4/2018 0:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.00 25 15.19 516 196 0.20 / 79.49 1 1
2 7 2002.76 43 14.48 3045 1896 2.09 / 81.39 1 1
3 13 1588.36 22 14.60 2532 813 2.91 / 82.20 1 1
4 13 996.64 22 14.78 1736 564 3.47 / 82.76 1 1
5 13 409.08 22 15.02 956 316 3.79 / 83.08 1 1
6 8 0.08 165 15.21 344 863 4.65 / 83.94 1 2
Average= 4.42
(KJ/cycle)

Cycle 17 GMT 22/ 3/2018 0:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.92 25 15.19 505 192 0.19 / 74.94 1 1
2 7 2003.68 42 14.48 3055 1858 2.05 / 76.80 1 1
3 13 1592.36 22 14.62 2509 807 2.86 / 77.60 1 1
4 13 1026.20 22 14.78 1756 571 3.43 / 78.17 1 1
5 13 305.64 22 15.09 792 263 3.69 / 78.44 1 1
6 8 0.08 165 15.21 341 856 4.55 / 79.29 1 1
Average= 4.41
(KJ/cycle)

Cycle 16 GMT 12/ 3/2018 0: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.56 25 15.20 503 191 0.19 / 70.24 1 1
2 7 2002.20 42 14.50 3026 1843 2.03 / 72.08 1 1
3 13 1744.48 22 14.58 2704 867 2.90 / 72.95 1 1
4 13 1148.40 22 14.74 1917 622 3.52 / 73.57 1 1
5 13 408.96 22 15.03 952 315 3.84 / 73.89 1 1
6 8 0.12 165 15.22 342 859 4.70 / 74.75 1 2
Average= 4.40
(KJ/cycle)

Cycle 15 GMT 1/ 3/2018 23:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.88 25 15.21 494 188 0.19 / 65.67 1 1
2 7 2004.12 43 14.50 3027 1887 2.08 / 67.56 1 1
3 13 1604.44 22 14.62 2512 808 2.88 / 68.37 1 1
4 13 1019.96 22 14.80 1744 568 3.45 / 68.94 1 1
5 13 294.12 22 15.10 787 261 3.71 / 69.20 1 1
6 8 0.08 165 15.22 340 854 4.57 / 70.05 1 2
Average= 4.38
(KJ/cycle)

Cycle 14 GMT 19/ 2/2018 23:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.04 25 15.20 514 195 0.20 / 61.18 1 1
2 7 2002.48 43 14.50 3015 1880 2.08 / 63.06 1 1
3 13 1588.64 22 14.64 2488 801 2.88 / 63.86 1 1
4 13 1007.48 22 14.80 1725 562 3.44 / 64.42 1 1
5 13 289.72 22 15.11 757 252 3.69 / 64.67 1 1
6 8 0.08 165 15.23 324 814 4.50 / 65.48 1 1
Average= 4.37
(KJ/cycle)

Cycle 13 GMT 9/ 2/2018 22:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.92 25 15.20 495 188 0.19 / 56.57 1 1
2 7 2001.84 42 14.51 3032 1848 2.04 / 58.42 1 1
3 13 1728.60 22 14.60 2708 870 2.91 / 59.29 1 1
4 13 1000.48 22 14.80 1728 563 3.47 / 59.85 1 1
5 13 297.56 22 15.10 802 266 3.73 / 60.12 1 1
6 8 0.12 165 15.23 342 859 4.59 / 60.98 1 1
Average= 4.36
(KJ/cycle)

Cycle 12 GMT 30/ 1/2018 22:17: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.16 25 15.21 501 191 0.19 / 51.91 1 1
2 7 2002.12 42 14.52 3024 1844 2.03 / 53.76 1 1
3 13 1588.28 22 14.65 2497 805 2.84 / 54.56 1 1
4 13 1024.32 22 14.81 1735 565 3.40 / 55.13 1 1
5 13 292.84 22 15.11 768 255 3.66 / 55.38 1 1
6 13 30.44 22 15.25 384 129 3.79 / 55.51 1 1
7 8 0.08 165 15.22 348 874 4.66 / 56.39 1 2
Average= 4.34
(KJ/cycle)

Cycle 11 GMT 20/ 1/2018 21:50: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 25 15.21 500 190 0.19 / 47.39 1 1
2 7 2003.12 43 14.52 3041 1899 2.09 / 49.29 1 1
3 13 1592.32 22 14.65 2511 809 2.90 / 50.10 1 1
4 13 873.04 22 14.86 1539 503 3.40 / 50.61 1 1
5 13 297.92 22 15.11 777 258 3.66 / 50.86 1 1
6 8 0.16 165 15.23 342 859 4.52 / 51.72 1 1
Average= 4.31
(KJ/cycle)

Cycle 10 GMT 10/ 1/2018 21:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 25 15.21 506 192 0.19 / 42.84 1 1
2 7 2004.08 43 14.51 3055 1906 2.10 / 44.75 1 1
3 13 1485.36 22 14.68 2375 767 2.87 / 45.52 1 1
4 13 915.08 22 14.85 1630 533 3.40 / 46.05 1 1
5 13 331.48 22 15.09 855 284 3.68 / 46.33 1 1
6 8 0.00 165 15.23 347 872 4.55 / 47.20 1 2
Average= 4.29
(KJ/cycle)

Cycle 9 GMT 31/12/2017 20:42: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.28 25 15.20 501 190 0.19 / 38.26 1 1
2 3 969.16 -1 15.59 0 0 0.00 / 38.26 1 1
3 7 2000.80 43 14.53 3029 1892 2.08 / 40.15 1 1
4 13 1579.12 22 14.65 2487 802 2.88 / 40.95 1 1
5 13 870.60 22 14.87 1552 508 3.39 / 41.46 1 1
6 13 433.28 22 15.04 982 325 3.72 / 41.79 1 1
7 8 0.08 165 15.23 344 864 4.58 / 42.65 1 2
Average= 4.27
(KJ/cycle)

Cycle 8 GMT 21/12/2017 20:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.32 24 15.21 480 175 0.18 / 33.45 1 1
2 3 1062.28 2 15.14 1894 57 0.23 / 33.51 1 1
3 3 1020.24 1 15.30 1844 28 0.26 / 33.54 1 1
4 7 2003.48 50 14.59 2718 1983 2.24 / 35.52 1 1
5 13 1451.68 22 14.85 1758 574 2.82 / 36.10 1 1
6 13 1036.56 22 14.87 1552 508 3.33 / 36.60 1 1
7 13 615.20 22 14.97 1209 398 3.72 / 37.00 1 1
8 13 173.68 22 15.18 613 205 3.93 / 37.21 1 1
9 8 0.16 165 15.23 343 862 4.79 / 38.07 1 3
Average= 4.23
(KJ/cycle)

Cycle 7 GMT 11/12/2017 19:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.84 23 15.23 504 177 0.18 / 28.36 1 1
2 7 2003.20 50 14.52 3026 2197 2.37 / 30.56 1 1
3 13 1415.08 22 14.71 2281 738 3.11 / 31.30 1 1
4 13 822.60 22 14.89 1506 493 3.60 / 31.79 1 1
5 13 215.04 22 15.16 680 227 3.83 / 32.02 1 1
6 8 0.08 240 15.22 345 1260 5.09 / 33.28 1 3
Average= 4.16
(KJ/cycle)

Cycle 6 GMT 1/12/2017 19:43:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.00 24 15.23 517 189 0.19 / 24.03 1 1
2 7 1504.44 50 14.75 2406 1774 1.96 / 25.80 1 1
3 13 1104.00 22 14.87 1866 610 2.57 / 26.41 1 1
4 13 544.60 22 15.05 1142 378 2.95 / 26.79 1 1
5 13 29.72 22 15.30 393 132 3.08 / 26.92 1 1
6 8 0.04 240 15.25 345 1263 4.35 / 28.19 1 7
Average= 4.03
(KJ/cycle)

Cycle 5 GMT 30/11/2017 20:10: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.60 24 15.22 507 185 0.19 / 19.63 1 1
2 7 1507.08 50 14.74 2418 1782 1.97 / 21.41 1 1
3 13 1241.16 22 14.83 2062 673 2.64 / 22.08 1 1
4 13 508.64 22 15.06 1086 360 3.00 / 22.44 1 1
5 13 49.60 22 15.29 423 142 3.14 / 22.58 1 1
6 8 0.08 240 15.25 343 1255 4.40 / 23.84 1 5
Average= 3.97
(KJ/cycle)

Cycle 4 GMT 29/11/2017 20:46: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.84 27 15.21 496 204 0.20 / 15.13 1 1
2 3 873.32 -2 15.59 0 0 0.00 / 15.13 1 1
3 3 948.36 -1 15.61 0 0 0.00 / 15.13 1 1
4 7 1507.20 50 14.74 2413 1778 1.98 / 16.91 1 1
5 13 1377.72 22 14.79 2232 726 2.71 / 17.64 1 1
6 13 628.68 22 15.01 1231 407 3.11 / 18.04 1 1
7 13 44.20 22 15.29 411 138 3.25 / 18.18 1 1
8 8 0.08 240 15.24 345 1262 4.51 / 19.44 1 4
Average= 3.89
(KJ/cycle)

Cycle 3 GMT 28/11/2017 21:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.24 36 15.20 513 281 0.28 / 10.64 1 1
2 3 687.24 -6 15.59 0 0 0.00 / 10.64 1 1
3 3 911.52 -2 15.60 0 0 0.00 / 10.64 1 1
4 7 1505.32 50 14.75 2390 1763 2.04 / 12.40 1 1
5 13 1245.04 22 14.82 2064 673 2.72 / 13.08 1 1
6 13 555.76 22 15.04 1153 382 3.10 / 13.46 1 1
7 13 130.72 22 15.23 559 187 3.29 / 13.64 1 1
8 8 0.04 240 15.23 351 1283 4.57 / 14.93 1 2
Average= 3.73
(KJ/cycle)

Cycle 2 GMT 27/11/2017 21:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.64 24 15.26 456 167 0.17 / 5.29 1 1
2 10 1008.76 5 15.02 1809 136 0.30 / 5.42 1 1
3 3 1222.84 6 14.94 2082 187 0.49 / 5.61 1 1
4 3 1176.08 4 14.98 2037 122 0.61 / 5.73 1 1
5 5 1330.32 8 14.88 2224 265 0.88 / 6.00 1 1
6 7 1506.80 74 14.70 2282 2482 3.36 / 8.48 1 1
7 13 501.24 25 15.03 1108 416 3.77 / 8.89 1 1
8 13 62.88 25 15.26 456 174 3.95 / 9.07 1 1
9 8 0.00 240 15.23 353 1290 5.24 / 10.36 1 4
Average= 3.45
(KJ/cycle)

Cycle 1 GMT 26/11/2017 23: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.08 25 15.43 427 165 0.16 / 1.88 1 2
2 10 1032.92 3 15.09 1862 84 0.25 / 1.96 1 1
3 3 1026.12 1 15.26 1889 29 0.28 / 1.99 1 1
4 3 1081.76 2 15.13 1915 58 0.34 / 2.05 1 1
5 7 1091.64 74 14.85 1789 1966 2.30 / 4.02 1 1
6 8 0.20 240 15.28 301 1104 3.41 / 5.12 1 4
Average= 2.56
(KJ/cycle)

Cycle 0 GMT 26/11/2017 11:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 126.80 25 15.59 480 187 0.19 / 0.19 1 2
2 7 136.20 74 15.55 473 544 0.73 / 0.73 2 1
3 8 0.52 240 15.51 264 983 1.71 / 1.71 1 8
Average= 1.71
(KJ/cycle)