SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.76 | 23 | 14.86 | 478 | 163 | 0.16 / 1127.70 | 2 | 2 |
2 | 7 | 2005.12 | 42 | 14.11 | 3029 | 1795 | 1.96 / 1129.50 | 2 | 2 |
3 | 13 | 1613.60 | 20 | 14.22 | 2533 | 720 | 2.68 / 1130.22 | 2 | 2 |
4 | 13 | 1045.72 | 20 | 14.41 | 1788 | 515 | 3.19 / 1130.74 | 2 | 2 |
5 | 13 | 463.76 | 20 | 14.68 | 996 | 292 | 3.49 / 1131.03 | 2 | 2 |
6 | 8 | 0.28 | 175 | 14.90 | 319 | 832 | 4.32 / 1131.86 | 2 | 3 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.28 | 23 | 14.85 | 485 | 166 | 0.17 / 1123.42 | 2 | 2 |
2 | 7 | 2003.64 | 42 | 14.10 | 3010 | 1783 | 1.95 / 1125.20 | 2 | 2 |
3 | 13 | 1596.88 | 20 | 14.23 | 2490 | 709 | 2.66 / 1125.91 | 2 | 2 |
4 | 13 | 1042.48 | 20 | 14.41 | 1779 | 513 | 3.17 / 1126.42 | 2 | 2 |
5 | 13 | 471.16 | 20 | 14.68 | 1002 | 294 | 3.46 / 1126.71 | 2 | 2 |
6 | 8 | 0.08 | 175 | 14.90 | 317 | 827 | 4.29 / 1127.54 | 2 | 2 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.40 | 23 | 14.86 | 480 | 164 | 0.16 / 1118.99 | 2 | 2 |
2 | 7 | 2003.72 | 42 | 14.11 | 3023 | 1791 | 1.96 / 1120.78 | 2 | 2 |
3 | 13 | 1599.32 | 20 | 14.23 | 2529 | 720 | 2.68 / 1121.50 | 2 | 2 |
4 | 13 | 1037.80 | 20 | 14.42 | 1773 | 511 | 3.19 / 1122.01 | 2 | 2 |
5 | 13 | 476.52 | 20 | 14.68 | 1014 | 298 | 3.48 / 1122.31 | 2 | 2 |
6 | 13 | 16.72 | 20 | 14.93 | 352 | 105 | 3.59 / 1122.41 | 2 | 2 |
7 | 8 | 0.36 | 175 | 14.89 | 321 | 836 | 4.43 / 1123.25 | 2 | 2 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.88 | 23 | 14.85 | 485 | 166 | 0.17 / 1114.54 | 2 | 2 |
2 | 7 | 2006.04 | 42 | 14.11 | 3020 | 1790 | 1.96 / 1116.33 | 2 | 2 |
3 | 13 | 1733.40 | 20 | 14.20 | 2682 | 762 | 2.72 / 1117.09 | 2 | 2 |
4 | 13 | 1025.32 | 20 | 14.44 | 1745 | 504 | 3.22 / 1117.59 | 2 | 2 |
5 | 13 | 455.76 | 20 | 14.69 | 982 | 289 | 3.51 / 1117.88 | 2 | 2 |
6 | 13 | 33.56 | 20 | 14.93 | 377 | 113 | 3.62 / 1118.00 | 2 | 2 |
7 | 8 | -0.08 | 175 | 14.90 | 318 | 829 | 4.45 / 1118.82 | 2 | 5 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.44 | 23 | 14.87 | 481 | 165 | 0.16 / 1110.08 | 2 | 2 |
2 | 7 | 2006.24 | 42 | 14.11 | 3007 | 1782 | 1.95 / 1111.87 | 2 | 2 |
3 | 13 | 1601.84 | 20 | 14.24 | 2513 | 716 | 2.66 / 1112.58 | 2 | 2 |
4 | 13 | 1171.68 | 20 | 14.37 | 1945 | 559 | 3.22 / 1113.14 | 2 | 2 |
5 | 13 | 452.56 | 20 | 14.70 | 973 | 286 | 3.51 / 1113.43 | 2 | 2 |
6 | 13 | 31.44 | 20 | 14.93 | 374 | 112 | 3.62 / 1113.54 | 2 | 2 |
7 | 8 | 0.28 | 175 | 14.90 | 320 | 834 | 4.45 / 1114.37 | 2 | 3 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.16 | 23 | 14.86 | 468 | 160 | 0.16 / 1105.73 | 2 | 2 |
2 | 7 | 2005.48 | 42 | 14.12 | 3014 | 1787 | 1.95 / 1107.52 | 2 | 2 |
3 | 13 | 1729.88 | 20 | 14.20 | 2685 | 763 | 2.71 / 1108.28 | 2 | 2 |
4 | 13 | 1028.16 | 20 | 14.43 | 1756 | 507 | 3.22 / 1108.79 | 2 | 2 |
5 | 13 | 463.84 | 20 | 14.69 | 998 | 293 | 3.51 / 1109.08 | 2 | 2 |
6 | 8 | 0.08 | 175 | 14.91 | 322 | 840 | 4.35 / 1109.92 | 2 | 3 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.88 | 23 | 14.86 | 475 | 162 | 0.16 / 1101.18 | 2 | 2 |
2 | 7 | 2009.36 | 42 | 14.11 | 3035 | 1799 | 1.96 / 1102.98 | 2 | 2 |
3 | 13 | 1742.48 | 20 | 14.19 | 2711 | 769 | 2.73 / 1103.75 | 2 | 2 |
4 | 13 | 1147.68 | 20 | 14.38 | 1910 | 549 | 3.28 / 1104.30 | 2 | 2 |
5 | 13 | 558.52 | 20 | 14.64 | 1127 | 330 | 3.61 / 1104.63 | 2 | 2 |
6 | 13 | 25.04 | 20 | 14.93 | 365 | 109 | 3.72 / 1104.74 | 2 | 2 |
7 | 8 | -0.04 | 175 | 14.90 | 320 | 834 | 4.55 / 1105.57 | 2 | 4 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.32 | 23 | 14.86 | 477 | 163 | 0.16 / 1096.71 | 2 | 2 |
2 | 7 | 2004.84 | 42 | 14.11 | 3021 | 1790 | 1.95 / 1098.50 | 2 | 2 |
3 | 13 | 1603.64 | 20 | 14.23 | 2514 | 715 | 2.67 / 1099.21 | 2 | 2 |
4 | 13 | 1175.04 | 20 | 14.37 | 1954 | 562 | 3.23 / 1099.78 | 2 | 2 |
5 | 13 | 463.88 | 20 | 14.69 | 1005 | 295 | 3.53 / 1100.07 | 2 | 2 |
6 | 13 | 16.96 | 20 | 14.94 | 357 | 107 | 3.63 / 1100.18 | 2 | 2 |
7 | 8 | 0.08 | 175 | 14.90 | 322 | 840 | 4.47 / 1101.02 | 2 | 4 |
Average= | 4.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.88 | 23 | 14.86 | 478 | 163 | 0.16 / 1092.39 | 2 | 2 |
2 | 7 | 2002.36 | 42 | 14.11 | 3017 | 1788 | 1.95 / 1094.18 | 2 | 2 |
3 | 13 | 1600.08 | 20 | 14.23 | 2531 | 720 | 2.67 / 1094.90 | 2 | 2 |
4 | 13 | 1032.00 | 20 | 14.43 | 1767 | 510 | 3.18 / 1095.41 | 2 | 2 |
5 | 13 | 461.84 | 20 | 14.69 | 998 | 293 | 3.47 / 1095.70 | 2 | 2 |
6 | 8 | 0.12 | 175 | 14.91 | 324 | 845 | 4.32 / 1096.55 | 2 | 6 |
Average= | 4.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.60 | 23 | 14.86 | 485 | 166 | 0.17 / 1088.07 | 2 | 2 |
2 | 7 | 2006.12 | 42 | 14.11 | 3008 | 1783 | 1.95 / 1089.85 | 2 | 2 |
3 | 13 | 1608.24 | 20 | 14.23 | 2527 | 719 | 2.67 / 1090.57 | 2 | 2 |
4 | 13 | 1053.00 | 20 | 14.42 | 1792 | 517 | 3.18 / 1091.08 | 2 | 2 |
5 | 13 | 482.52 | 20 | 14.68 | 1028 | 302 | 3.49 / 1091.39 | 2 | 2 |
6 | 8 | 0.32 | 175 | 14.90 | 322 | 840 | 4.33 / 1092.23 | 2 | 2 |
Average= | 4.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.68 | 23 | 14.85 | 478 | 163 | 0.16 / 1083.76 | 2 | 2 |
2 | 7 | 2004.32 | 42 | 14.11 | 3016 | 1787 | 1.95 / 1085.54 | 2 | 2 |
3 | 13 | 1596.60 | 20 | 14.23 | 2497 | 711 | 2.66 / 1086.25 | 2 | 2 |
4 | 13 | 1026.96 | 20 | 14.43 | 1757 | 507 | 3.17 / 1086.76 | 2 | 2 |
5 | 13 | 461.84 | 20 | 14.69 | 1006 | 296 | 3.46 / 1087.06 | 2 | 2 |
6 | 8 | 0.04 | 175 | 14.90 | 323 | 842 | 4.31 / 1087.90 | 2 | 3 |
Average= | 4.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.76 | 23 | 14.86 | 482 | 165 | 0.16 / 1079.33 | 2 | 2 |
2 | 7 | 2005.72 | 42 | 14.11 | 3024 | 1792 | 1.96 / 1081.12 | 2 | 2 |
3 | 13 | 1597.44 | 20 | 14.24 | 2510 | 715 | 2.67 / 1081.83 | 2 | 2 |
4 | 13 | 1036.32 | 20 | 14.43 | 1774 | 512 | 3.18 / 1082.34 | 2 | 2 |
5 | 13 | 466.76 | 20 | 14.70 | 1008 | 296 | 3.48 / 1082.64 | 2 | 2 |
6 | 13 | 16.84 | 20 | 14.94 | 359 | 107 | 3.59 / 1082.75 | 2 | 2 |
7 | 8 | -0.04 | 175 | 14.90 | 324 | 845 | 4.43 / 1083.59 | 2 | 3 |
Average= | 4.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.20 | 23 | 14.86 | 489 | 167 | 0.17 / 1074.95 | 2 | 2 |
2 | 7 | 2005.48 | 42 | 14.11 | 3018 | 1789 | 1.96 / 1076.74 | 2 | 2 |
3 | 13 | 1735.04 | 20 | 14.19 | 2703 | 767 | 2.72 / 1077.51 | 2 | 2 |
4 | 13 | 1024.00 | 20 | 14.44 | 1765 | 510 | 3.23 / 1078.02 | 2 | 2 |
5 | 13 | 462.40 | 20 | 14.69 | 1005 | 295 | 3.53 / 1078.31 | 2 | 2 |
6 | 8 | 0.20 | 175 | 14.91 | 325 | 848 | 4.38 / 1079.16 | 2 | 5 |
Average= | 4.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.20 | 23 | 14.87 | 493 | 169 | 0.17 / 1070.62 | 2 | 2 |
2 | 7 | 2004.00 | 42 | 14.11 | 3015 | 1787 | 1.96 / 1072.41 | 2 | 2 |
3 | 13 | 1591.96 | 20 | 14.23 | 2517 | 716 | 2.67 / 1073.12 | 2 | 2 |
4 | 13 | 1029.08 | 20 | 14.43 | 1764 | 509 | 3.18 / 1073.63 | 2 | 2 |
5 | 13 | 463.48 | 20 | 14.69 | 1002 | 294 | 3.48 / 1073.93 | 2 | 2 |
6 | 8 | 0.40 | 175 | 14.90 | 329 | 858 | 4.33 / 1074.79 | 2 | 3 |
Average= | 4.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.84 | 23 | 14.87 | 495 | 169 | 0.17 / 1066.30 | 2 | 2 |
2 | 7 | 2008.76 | 43 | 14.10 | 3020 | 1831 | 2.00 / 1068.13 | 2 | 2 |
3 | 13 | 1617.68 | 20 | 14.22 | 2539 | 722 | 2.72 / 1068.85 | 2 | 2 |
4 | 13 | 1045.32 | 20 | 14.42 | 1785 | 515 | 3.24 / 1069.36 | 2 | 2 |
5 | 13 | 338.68 | 20 | 14.76 | 823 | 243 | 3.48 / 1069.61 | 2 | 2 |
6 | 8 | 0.12 | 175 | 14.91 | 324 | 845 | 4.33 / 1070.45 | 2 | 2 |
Average= | 4.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.12 | 23 | 14.86 | 491 | 168 | 0.17 / 1061.85 | 2 | 2 |
2 | 7 | 2006.36 | 42 | 14.11 | 3015 | 1787 | 1.95 / 1063.64 | 2 | 2 |
3 | 13 | 1603.00 | 20 | 14.22 | 2528 | 719 | 2.67 / 1064.36 | 2 | 2 |
4 | 13 | 1182.64 | 20 | 14.36 | 1965 | 564 | 3.24 / 1064.92 | 2 | 2 |
5 | 13 | 591.44 | 20 | 14.63 | 1183 | 346 | 3.58 / 1065.27 | 2 | 2 |
6 | 8 | 0.32 | 175 | 14.91 | 328 | 856 | 4.44 / 1066.13 | 2 | 2 |
Average= | 4.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.24 | 24 | 14.87 | 476 | 170 | 0.17 / 1057.02 | 2 | 2 |
2 | 3 | 968.76 | -1 | 15.35 | 0 | 0 | 0.00 / 1057.02 | 2 | 2 |
3 | 3 | 1023.04 | 1 | 15.01 | 1857 | 28 | 0.20 / 1057.05 | 2 | 2 |
4 | 7 | 2005.28 | 42 | 14.10 | 3022 | 1790 | 1.99 / 1058.84 | 2 | 2 |
5 | 13 | 1735.20 | 20 | 14.19 | 2681 | 761 | 2.75 / 1059.60 | 2 | 2 |
6 | 13 | 1033.28 | 20 | 14.43 | 1771 | 511 | 3.26 / 1060.11 | 2 | 2 |
7 | 13 | 597.04 | 20 | 14.62 | 1196 | 350 | 3.61 / 1060.46 | 2 | 2 |
8 | 13 | 315.32 | 20 | 14.76 | 799 | 236 | 3.84 / 1060.69 | 2 | 2 |
9 | 13 | 85.12 | 20 | 14.88 | 467 | 139 | 3.98 / 1060.83 | 2 | 2 |
10 | 8 | -0.04 | 175 | 14.88 | 328 | 854 | 4.84 / 1061.69 | 2 | 5 |
Average= | 4.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.92 | 23 | 14.86 | 476 | 163 | 0.16 / 1052.74 | 2 | 2 |
2 | 7 | 2002.96 | 42 | 14.11 | 3021 | 1790 | 1.95 / 1054.53 | 2 | 2 |
3 | 13 | 1605.44 | 20 | 14.23 | 2522 | 718 | 2.67 / 1055.25 | 2 | 2 |
4 | 13 | 1052.60 | 20 | 14.42 | 1788 | 516 | 3.19 / 1055.77 | 2 | 2 |
5 | 13 | 353.52 | 20 | 14.76 | 843 | 249 | 3.44 / 1056.02 | 2 | 2 |
6 | 8 | 0.00 | 175 | 14.91 | 319 | 832 | 4.27 / 1056.85 | 2 | 4 |
Average= | 4.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.20 | 23 | 14.87 | 475 | 162 | 0.16 / 1048.28 | 2 | 2 |
2 | 7 | 2006.36 | 42 | 14.11 | 3012 | 1785 | 1.95 / 1050.06 | 2 | 2 |
3 | 13 | 1733.60 | 20 | 14.19 | 2696 | 765 | 2.71 / 1050.83 | 2 | 2 |
4 | 13 | 1028.40 | 20 | 14.43 | 1761 | 508 | 3.22 / 1051.33 | 2 | 2 |
5 | 13 | 472.20 | 20 | 14.69 | 1013 | 298 | 3.52 / 1051.63 | 2 | 2 |
6 | 13 | 44.80 | 20 | 14.92 | 393 | 117 | 3.64 / 1051.75 | 2 | 2 |
7 | 8 | 0.00 | 175 | 14.90 | 319 | 832 | 4.47 / 1052.58 | 2 | 3 |
Average= | 4.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.76 | 23 | 14.87 | 475 | 162 | 0.16 / 1043.72 | 2 | 2 |
2 | 7 | 2003.56 | 42 | 14.11 | 3016 | 1787 | 1.95 / 1045.51 | 2 | 2 |
3 | 13 | 1721.12 | 20 | 14.20 | 2668 | 758 | 2.71 / 1046.26 | 2 | 2 |
4 | 13 | 1269.44 | 20 | 14.33 | 2081 | 596 | 3.30 / 1046.86 | 2 | 2 |
5 | 13 | 523.16 | 20 | 14.67 | 1079 | 317 | 3.62 / 1047.18 | 2 | 2 |
6 | 13 | 23.36 | 20 | 14.94 | 359 | 107 | 3.73 / 1047.28 | 2 | 2 |
7 | 8 | 0.16 | 175 | 14.90 | 318 | 829 | 4.56 / 1048.11 | 2 | 5 |
Average= | 4.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.88 | 23 | 14.86 | 464 | 159 | 0.16 / 1039.18 | 2 | 2 |
2 | 7 | 2006.24 | 42 | 14.11 | 3006 | 1781 | 1.94 / 1040.96 | 2 | 2 |
3 | 13 | 1737.36 | 20 | 14.19 | 2691 | 764 | 2.70 / 1041.73 | 2 | 2 |
4 | 13 | 1158.24 | 20 | 14.37 | 1924 | 553 | 3.26 / 1042.28 | 2 | 2 |
5 | 13 | 560.76 | 20 | 14.64 | 1128 | 330 | 3.59 / 1042.61 | 2 | 2 |
6 | 13 | 56.84 | 20 | 14.91 | 410 | 122 | 3.71 / 1042.73 | 2 | 2 |
7 | 8 | 0.28 | 175 | 14.90 | 316 | 824 | 4.53 / 1043.56 | 2 | 3 |
Average= | 4.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.28 | 23 | 14.86 | 469 | 160 | 0.16 / 1034.77 | 2 | 2 |
2 | 7 | 2001.92 | 42 | 14.11 | 3019 | 1789 | 1.95 / 1036.56 | 2 | 2 |
3 | 13 | 1601.88 | 20 | 14.23 | 2515 | 716 | 2.67 / 1037.27 | 2 | 2 |
4 | 13 | 1039.52 | 20 | 14.42 | 1772 | 511 | 3.18 / 1037.79 | 2 | 2 |
5 | 13 | 466.68 | 20 | 14.68 | 1007 | 296 | 3.47 / 1038.08 | 2 | 2 |
6 | 13 | 36.00 | 20 | 14.91 | 383 | 114 | 3.59 / 1038.19 | 2 | 2 |
7 | 8 | -0.08 | 175 | 14.89 | 318 | 829 | 4.41 / 1039.02 | 2 | 4 |
Average= | 4.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.00 | 24 | 14.85 | 472 | 168 | 0.17 / 1030.34 | 2 | 2 |
2 | 3 | 968.52 | -1 | 15.34 | 0 | 0 | 0.00 / 1030.34 | 2 | 2 |
3 | 3 | 1025.44 | 1 | 15.01 | 1872 | 28 | 0.20 / 1030.37 | 2 | 2 |
4 | 7 | 2006.20 | 42 | 14.11 | 3014 | 1786 | 1.98 / 1032.15 | 2 | 2 |
5 | 13 | 1599.60 | 20 | 14.21 | 2526 | 718 | 2.70 / 1032.87 | 2 | 2 |
6 | 13 | 1035.32 | 20 | 14.42 | 1769 | 510 | 3.21 / 1033.38 | 2 | 2 |
7 | 13 | 459.72 | 20 | 14.68 | 995 | 292 | 3.50 / 1033.67 | 2 | 2 |
8 | 13 | 33.32 | 20 | 14.91 | 375 | 112 | 3.61 / 1033.79 | 2 | 2 |
9 | 8 | 0.20 | 175 | 14.89 | 316 | 823 | 4.44 / 1034.61 | 2 | 3 |
Average= | 4.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.84 | 24 | 14.87 | 469 | 167 | 0.17 / 1025.92 | 2 | 2 |
2 | 7 | 2007.24 | 42 | 14.11 | 3011 | 1784 | 1.95 / 1027.70 | 2 | 2 |
3 | 13 | 1611.68 | 20 | 14.22 | 2515 | 715 | 2.67 / 1028.42 | 2 | 2 |
4 | 13 | 1048.48 | 20 | 14.42 | 1780 | 513 | 3.18 / 1028.93 | 2 | 2 |
5 | 13 | 486.52 | 20 | 14.67 | 1026 | 301 | 3.48 / 1029.23 | 2 | 2 |
6 | 13 | 41.48 | 20 | 14.91 | 389 | 116 | 3.60 / 1029.35 | 2 | 2 |
7 | 8 | 0.28 | 175 | 14.89 | 316 | 823 | 4.42 / 1030.17 | 2 | 3 |
Average= | 4.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.96 | 24 | 14.86 | 459 | 164 | 0.16 / 1021.33 | 2 | 2 |
2 | 7 | 2007.56 | 42 | 14.11 | 3014 | 1786 | 1.95 / 1023.12 | 2 | 2 |
3 | 13 | 1602.28 | 20 | 14.22 | 2510 | 714 | 2.66 / 1023.83 | 2 | 2 |
4 | 13 | 1178.16 | 20 | 14.36 | 1946 | 559 | 3.22 / 1024.39 | 2 | 2 |
5 | 13 | 451.72 | 20 | 14.69 | 977 | 287 | 3.51 / 1024.68 | 2 | 2 |
6 | 13 | 36.44 | 20 | 14.91 | 379 | 113 | 3.62 / 1024.79 | 2 | 2 |
7 | 8 | 0.12 | 175 | 14.89 | 315 | 821 | 4.44 / 1025.61 | 2 | 4 |
8 | 14 | 0.12 | 30 | 14.87 | 314 | 140 | 4.58 / 1025.75 | 2 | 3 |
Average= | 4.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.00 | 24 | 14.87 | 457 | 163 | 0.16 / 1016.89 | 2 | 2 |
2 | 7 | 2007.12 | 42 | 14.11 | 3008 | 1783 | 1.95 / 1018.67 | 2 | 2 |
3 | 13 | 1739.40 | 20 | 14.18 | 2699 | 765 | 2.71 / 1019.43 | 2 | 2 |
4 | 13 | 1036.40 | 20 | 14.42 | 1757 | 507 | 3.22 / 1019.94 | 2 | 2 |
5 | 13 | 465.32 | 20 | 14.68 | 995 | 292 | 3.51 / 1020.23 | 2 | 2 |
6 | 13 | 37.04 | 20 | 14.90 | 383 | 114 | 3.62 / 1020.35 | 2 | 2 |
7 | 8 | 0.16 | 175 | 14.88 | 315 | 820 | 4.44 / 1021.17 | 2 | 3 |
Average= | 4.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.08 | 23 | 14.86 | 461 | 158 | 0.16 / 1012.54 | 2 | 2 |
2 | 7 | 2002.96 | 42 | 14.12 | 3011 | 1786 | 1.94 / 1014.33 | 2 | 2 |
3 | 13 | 1598.92 | 20 | 14.22 | 2506 | 713 | 2.66 / 1015.04 | 2 | 2 |
4 | 13 | 1036.24 | 20 | 14.42 | 1746 | 504 | 3.16 / 1015.55 | 2 | 2 |
5 | 13 | 341.52 | 20 | 14.74 | 829 | 244 | 3.40 / 1015.79 | 2 | 2 |
6 | 13 | 23.80 | 20 | 14.91 | 366 | 109 | 3.51 / 1015.90 | 2 | 2 |
7 | 8 | 0.12 | 175 | 14.89 | 316 | 823 | 4.34 / 1016.72 | 2 | 6 |
Average= | 4.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.32 | 23 | 14.85 | 462 | 158 | 0.16 / 1008.10 | 2 | 2 |
2 | 7 | 2003.56 | 42 | 14.11 | 3001 | 1778 | 1.94 / 1009.88 | 2 | 2 |
3 | 13 | 1730.48 | 20 | 14.19 | 2678 | 760 | 2.70 / 1010.64 | 2 | 2 |
4 | 13 | 1144.12 | 20 | 14.37 | 1897 | 545 | 3.24 / 1011.19 | 2 | 2 |
5 | 13 | 431.08 | 20 | 14.70 | 938 | 276 | 3.52 / 1011.46 | 2 | 2 |
6 | 13 | 33.80 | 20 | 14.91 | 370 | 110 | 3.63 / 1011.57 | 2 | 2 |
7 | 8 | 0.12 | 175 | 14.89 | 312 | 813 | 4.44 / 1012.39 | 2 | 4 |
Average= | 4.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.64 | 23 | 14.85 | 473 | 162 | 0.16 / 1003.64 | 2 | 2 |
2 | 7 | 2008.48 | 43 | 14.10 | 3008 | 1824 | 1.99 / 1005.46 | 2 | 2 |
3 | 13 | 1613.72 | 20 | 14.21 | 2547 | 724 | 2.71 / 1006.19 | 2 | 2 |
4 | 13 | 1172.60 | 20 | 14.35 | 1950 | 560 | 3.27 / 1006.75 | 2 | 2 |
5 | 13 | 429.32 | 20 | 14.69 | 950 | 279 | 3.55 / 1007.02 | 2 | 2 |
6 | 13 | 28.92 | 20 | 14.90 | 363 | 108 | 3.66 / 1007.13 | 2 | 2 |
7 | 8 | 0.20 | 175 | 14.88 | 312 | 812 | 4.47 / 1007.95 | 2 | 3 |
Average= | 4.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.00 | 24 | 14.85 | 472 | 168 | 0.17 / 999.20 | 2 | 2 |
2 | 3 | 967.68 | -1 | 15.33 | 0 | 0 | 0.00 / 999.20 | 2 | 2 |
3 | 3 | 1018.04 | 1 | 15.01 | 1880 | 28 | 0.20 / 999.23 | 2 | 2 |
4 | 7 | 2007.36 | 42 | 14.10 | 3015 | 1785 | 1.98 / 1001.02 | 2 | 2 |
5 | 13 | 1605.40 | 20 | 14.21 | 2528 | 718 | 2.70 / 1001.73 | 2 | 2 |
6 | 13 | 1044.52 | 20 | 14.41 | 1781 | 513 | 3.21 / 1002.25 | 2 | 2 |
7 | 13 | 465.68 | 20 | 14.67 | 1007 | 295 | 3.51 / 1002.54 | 2 | 2 |
8 | 13 | 18.60 | 20 | 14.91 | 354 | 106 | 3.61 / 1002.65 | 2 | 2 |
9 | 8 | -0.08 | 175 | 14.88 | 318 | 828 | 4.44 / 1003.48 | 2 | 3 |
Average= | 4.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.24 | 24 | 14.85 | 465 | 166 | 0.17 / 994.76 | 2 | 2 |
2 | 7 | 2002.32 | 42 | 14.12 | 3008 | 1784 | 1.95 / 996.54 | 2 | 2 |
3 | 13 | 1736.36 | 20 | 14.19 | 2691 | 764 | 2.71 / 997.31 | 2 | 2 |
4 | 13 | 1036.60 | 20 | 14.41 | 1762 | 508 | 3.22 / 997.81 | 2 | 2 |
5 | 13 | 476.52 | 20 | 14.67 | 1011 | 297 | 3.52 / 998.11 | 2 | 2 |
6 | 13 | 18.52 | 20 | 14.91 | 356 | 106 | 3.62 / 998.22 | 2 | 2 |
7 | 8 | 0.16 | 175 | 14.88 | 314 | 818 | 4.44 / 999.03 | 2 | 5 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.40 | 24 | 14.85 | 480 | 171 | 0.17 / 990.28 | 2 | 2 |
2 | 7 | 2003.08 | 42 | 14.11 | 3017 | 1788 | 1.96 / 992.07 | 2 | 2 |
3 | 13 | 1734.08 | 20 | 14.18 | 2688 | 762 | 2.72 / 992.83 | 2 | 2 |
4 | 13 | 1151.80 | 20 | 14.36 | 1908 | 548 | 3.27 / 993.38 | 2 | 2 |
5 | 13 | 420.92 | 20 | 14.69 | 937 | 275 | 3.54 / 993.66 | 2 | 2 |
6 | 13 | 26.56 | 20 | 14.90 | 368 | 110 | 3.65 / 993.77 | 2 | 2 |
7 | 8 | 0.36 | 175 | 14.87 | 317 | 825 | 4.48 / 994.59 | 2 | 5 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.28 | 24 | 14.84 | 491 | 175 | 0.17 / 985.99 | 2 | 2 |
2 | 7 | 2001.72 | 42 | 14.11 | 3017 | 1788 | 1.96 / 987.78 | 2 | 2 |
3 | 13 | 1585.60 | 20 | 14.22 | 2498 | 710 | 2.67 / 988.49 | 2 | 2 |
4 | 13 | 1029.24 | 20 | 14.41 | 1761 | 508 | 3.18 / 989.00 | 2 | 2 |
5 | 13 | 452.96 | 20 | 14.67 | 984 | 289 | 3.47 / 989.29 | 2 | 2 |
6 | 8 | 0.12 | 175 | 14.88 | 318 | 828 | 4.30 / 990.11 | 2 | 3 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.12 | 24 | 14.84 | 471 | 168 | 0.17 / 981.59 | 2 | 2 |
2 | 7 | 2002.32 | 42 | 14.11 | 3018 | 1789 | 1.96 / 983.38 | 2 | 2 |
3 | 13 | 1739.00 | 20 | 14.18 | 2697 | 765 | 2.72 / 984.14 | 2 | 2 |
4 | 13 | 1150.36 | 20 | 14.36 | 1910 | 549 | 3.27 / 984.69 | 2 | 2 |
5 | 13 | 435.52 | 20 | 14.68 | 963 | 283 | 3.55 / 984.97 | 2 | 2 |
6 | 8 | 0.20 | 175 | 14.88 | 323 | 841 | 4.39 / 985.82 | 2 | 3 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.92 | 24 | 14.84 | 480 | 171 | 0.17 / 977.28 | 2 | 2 |
2 | 7 | 2004.56 | 42 | 14.11 | 3011 | 1784 | 1.96 / 979.07 | 2 | 2 |
3 | 13 | 1606.80 | 20 | 14.21 | 2519 | 716 | 2.67 / 979.78 | 2 | 2 |
4 | 13 | 1045.32 | 20 | 14.40 | 1783 | 514 | 3.18 / 980.30 | 2 | 2 |
5 | 13 | 473.44 | 20 | 14.66 | 1011 | 296 | 3.48 / 980.59 | 2 | 2 |
6 | 8 | 0.08 | 175 | 14.88 | 318 | 828 | 4.31 / 981.42 | 2 | 2 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.72 | 24 | 14.83 | 486 | 173 | 0.17 / 973.04 | 2 | 2 |
2 | 7 | 2002.88 | 42 | 14.11 | 3003 | 1780 | 1.95 / 974.82 | 2 | 2 |
3 | 13 | 1596.76 | 20 | 14.22 | 2501 | 711 | 2.66 / 975.53 | 2 | 2 |
4 | 13 | 1041.80 | 20 | 14.40 | 1775 | 511 | 3.18 / 976.04 | 2 | 2 |
5 | 13 | 340.76 | 20 | 14.73 | 828 | 244 | 3.42 / 976.28 | 2 | 2 |
6 | 8 | 0.20 | 175 | 14.88 | 319 | 831 | 4.25 / 977.11 | 2 | 2 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.04 | 23 | 14.84 | 485 | 166 | 0.17 / 968.69 | 2 | 2 |
2 | 7 | 2002.92 | 43 | 14.11 | 3012 | 1827 | 1.99 / 970.52 | 2 | 2 |
3 | 13 | 1591.24 | 20 | 14.21 | 2526 | 718 | 2.71 / 971.24 | 2 | 2 |
4 | 13 | 1026.96 | 20 | 14.42 | 1740 | 502 | 3.21 / 971.74 | 2 | 2 |
5 | 13 | 452.48 | 20 | 14.67 | 985 | 289 | 3.50 / 972.03 | 2 | 2 |
6 | 8 | 0.08 | 175 | 14.87 | 321 | 835 | 4.34 / 972.86 | 2 | 3 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.80 | 23 | 14.83 | 474 | 162 | 0.16 / 964.45 | 2 | 2 |
2 | 7 | 2008.36 | 42 | 14.12 | 3016 | 1789 | 1.95 / 966.24 | 2 | 2 |
3 | 13 | 1601.64 | 20 | 14.22 | 2518 | 716 | 2.67 / 966.95 | 2 | 2 |
4 | 13 | 1039.60 | 20 | 14.40 | 1773 | 511 | 3.18 / 967.46 | 2 | 2 |
5 | 13 | 346.36 | 20 | 14.73 | 828 | 244 | 3.42 / 967.71 | 2 | 2 |
6 | 8 | 0.08 | 175 | 14.88 | 315 | 820 | 4.24 / 968.53 | 2 | 3 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.04 | 24 | 14.82 | 480 | 171 | 0.17 / 960.09 | 2 | 2 |
2 | 7 | 2001.32 | 42 | 14.12 | 3003 | 1781 | 1.95 / 961.87 | 2 | 2 |
3 | 13 | 1727.16 | 20 | 14.18 | 2679 | 760 | 2.71 / 962.63 | 2 | 2 |
4 | 13 | 1146.44 | 20 | 14.36 | 1921 | 552 | 3.26 / 963.18 | 2 | 2 |
5 | 13 | 419.68 | 20 | 14.69 | 935 | 275 | 3.54 / 963.46 | 2 | 2 |
6 | 8 | 0.04 | 175 | 14.88 | 318 | 828 | 4.37 / 964.28 | 2 | 2 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.04 | 24 | 14.83 | 468 | 167 | 0.17 / 955.76 | 2 | 2 |
2 | 7 | 2004.64 | 43 | 14.11 | 3021 | 1833 | 2.00 / 957.59 | 2 | 2 |
3 | 13 | 1586.48 | 20 | 14.22 | 2498 | 710 | 2.71 / 958.31 | 2 | 2 |
4 | 13 | 1026.64 | 20 | 14.41 | 1748 | 504 | 3.21 / 958.81 | 2 | 2 |
5 | 13 | 449.36 | 20 | 14.67 | 972 | 285 | 3.50 / 959.09 | 2 | 2 |
6 | 8 | 0.04 | 175 | 14.87 | 317 | 825 | 4.32 / 959.92 | 2 | 3 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.44 | 24 | 14.82 | 482 | 171 | 0.17 / 951.48 | 2 | 2 |
2 | 7 | 2007.16 | 43 | 14.11 | 3019 | 1832 | 2.00 / 953.31 | 2 | 2 |
3 | 13 | 1592.80 | 20 | 14.22 | 2492 | 709 | 2.71 / 954.02 | 2 | 2 |
4 | 13 | 1033.12 | 20 | 14.40 | 1757 | 506 | 3.22 / 954.53 | 2 | 2 |
5 | 13 | 329.00 | 20 | 14.73 | 808 | 238 | 3.46 / 954.77 | 2 | 2 |
6 | 8 | 0.36 | 175 | 14.87 | 319 | 830 | 4.29 / 955.60 | 2 | 2 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.16 | 24 | 14.82 | 485 | 173 | 0.17 / 947.19 | 2 | 2 |
2 | 7 | 2002.72 | 43 | 14.11 | 3019 | 1832 | 2.00 / 949.02 | 2 | 2 |
3 | 13 | 1593.60 | 20 | 14.22 | 2514 | 715 | 2.72 / 949.73 | 2 | 2 |
4 | 13 | 1030.64 | 20 | 14.40 | 1756 | 506 | 3.22 / 950.24 | 2 | 2 |
5 | 13 | 326.52 | 20 | 14.74 | 802 | 236 | 3.46 / 950.48 | 2 | 2 |
6 | 8 | 0.08 | 175 | 14.87 | 320 | 833 | 4.29 / 951.31 | 2 | 3 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.36 | 24 | 14.83 | 481 | 171 | 0.17 / 942.87 | 2 | 2 |
2 | 7 | 2006.64 | 42 | 14.11 | 3019 | 1789 | 1.96 / 944.66 | 2 | 2 |
3 | 13 | 1601.12 | 20 | 14.22 | 2512 | 714 | 2.67 / 945.38 | 2 | 2 |
4 | 13 | 1041.52 | 20 | 14.40 | 1776 | 511 | 3.19 / 945.89 | 2 | 2 |
5 | 13 | 462.68 | 20 | 14.66 | 1001 | 293 | 3.48 / 946.18 | 2 | 2 |
6 | 8 | 0.32 | 175 | 14.87 | 320 | 833 | 4.31 / 947.02 | 2 | 2 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.32 | 24 | 14.83 | 483 | 172 | 0.17 / 938.58 | 2 | 2 |
2 | 7 | 2003.28 | 42 | 14.12 | 3020 | 1791 | 1.96 / 940.37 | 2 | 2 |
3 | 13 | 1589.96 | 20 | 14.24 | 2486 | 708 | 2.67 / 941.08 | 2 | 2 |
4 | 13 | 1030.52 | 20 | 14.40 | 1765 | 508 | 3.18 / 941.59 | 2 | 2 |
5 | 13 | 457.76 | 20 | 14.67 | 988 | 290 | 3.47 / 941.88 | 2 | 2 |
6 | 8 | -0.08 | 175 | 14.88 | 316 | 823 | 4.29 / 942.70 | 2 | 2 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.40 | 24 | 14.83 | 469 | 167 | 0.17 / 934.25 | 2 | 2 |
2 | 7 | 2003.60 | 42 | 14.12 | 3024 | 1793 | 1.96 / 936.04 | 2 | 2 |
3 | 13 | 1730.32 | 20 | 14.19 | 2690 | 763 | 2.72 / 936.81 | 2 | 2 |
4 | 13 | 1009.28 | 20 | 14.42 | 1730 | 499 | 3.22 / 937.31 | 2 | 2 |
5 | 13 | 442.12 | 20 | 14.68 | 963 | 283 | 3.51 / 937.59 | 2 | 2 |
6 | 8 | 0.16 | 175 | 14.88 | 316 | 823 | 4.33 / 938.41 | 2 | 2 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.48 | 23 | 14.83 | 474 | 162 | 0.16 / 929.86 | 2 | 2 |
2 | 7 | 2002.96 | 42 | 14.12 | 3014 | 1787 | 1.95 / 931.65 | 2 | 2 |
3 | 13 | 1732.56 | 20 | 14.18 | 2692 | 763 | 2.71 / 932.41 | 2 | 2 |
4 | 13 | 1150.44 | 20 | 14.36 | 1917 | 551 | 3.26 / 932.96 | 2 | 2 |
5 | 13 | 441.24 | 20 | 14.68 | 968 | 284 | 3.55 / 933.24 | 2 | 2 |
6 | 8 | 0.36 | 175 | 14.88 | 322 | 838 | 4.39 / 934.08 | 2 | 3 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.96 | 23 | 14.83 | 490 | 167 | 0.17 / 925.61 | 2 | 2 |
2 | 7 | 2003.20 | 42 | 14.12 | 3026 | 1795 | 1.96 / 927.41 | 2 | 2 |
3 | 13 | 1584.76 | 20 | 14.23 | 2497 | 711 | 2.67 / 928.12 | 2 | 2 |
4 | 13 | 1017.80 | 20 | 14.41 | 1748 | 504 | 3.18 / 928.62 | 2 | 2 |
5 | 13 | 324.84 | 20 | 14.74 | 807 | 238 | 3.41 / 928.86 | 2 | 2 |
6 | 8 | -0.16 | 175 | 14.88 | 321 | 836 | 4.25 / 929.70 | 2 | 3 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.72 | 23 | 14.83 | 486 | 166 | 0.17 / 921.36 | 2 | 2 |
2 | 7 | 2002.92 | 42 | 14.12 | 3015 | 1788 | 1.95 / 923.15 | 2 | 2 |
3 | 13 | 1595.96 | 20 | 14.22 | 2510 | 714 | 2.67 / 923.86 | 2 | 2 |
4 | 13 | 1032.84 | 20 | 14.41 | 1768 | 510 | 3.18 / 924.37 | 2 | 2 |
5 | 13 | 330.60 | 20 | 14.74 | 813 | 240 | 3.42 / 924.61 | 2 | 2 |
6 | 8 | 0.16 | 175 | 14.88 | 320 | 833 | 4.25 / 925.45 | 2 | 2 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.00 | 23 | 14.84 | 470 | 160 | 0.16 / 917.03 | 2 | 2 |
2 | 7 | 2004.48 | 42 | 14.12 | 3019 | 1790 | 1.95 / 918.83 | 2 | 2 |
3 | 13 | 1592.80 | 20 | 14.23 | 2501 | 712 | 2.66 / 919.54 | 2 | 2 |
4 | 13 | 1152.28 | 20 | 14.35 | 1933 | 555 | 3.22 / 920.09 | 2 | 2 |
5 | 13 | 426.44 | 20 | 14.69 | 942 | 277 | 3.49 / 920.37 | 2 | 2 |
6 | 8 | 0.08 | 175 | 14.88 | 318 | 828 | 4.32 / 921.20 | 2 | 2 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.64 | 23 | 14.83 | 481 | 164 | 0.16 / 912.67 | 2 | 2 |
2 | 7 | 2002.76 | 43 | 14.12 | 3016 | 1831 | 2.00 / 914.50 | 2 | 2 |
3 | 13 | 1729.60 | 20 | 14.19 | 2698 | 766 | 2.76 / 915.26 | 2 | 2 |
4 | 13 | 1001.84 | 20 | 14.43 | 1718 | 496 | 3.26 / 915.76 | 2 | 2 |
5 | 13 | 434.20 | 20 | 14.68 | 955 | 280 | 3.54 / 916.04 | 2 | 2 |
6 | 8 | 0.20 | 175 | 14.88 | 321 | 836 | 4.37 / 916.87 | 2 | 2 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.16 | 23 | 14.84 | 473 | 161 | 0.16 / 908.34 | 2 | 2 |
2 | 7 | 2003.24 | 42 | 14.12 | 3022 | 1792 | 1.95 / 910.13 | 2 | 2 |
3 | 13 | 1595.68 | 20 | 14.22 | 2503 | 712 | 2.67 / 910.85 | 2 | 2 |
4 | 13 | 1015.36 | 20 | 14.42 | 1727 | 498 | 3.16 / 911.34 | 2 | 2 |
5 | 13 | 188.88 | 20 | 14.81 | 607 | 180 | 3.34 / 911.52 | 2 | 2 |
6 | 8 | 0.40 | 175 | 14.88 | 320 | 833 | 4.18 / 912.36 | 2 | 3 |
7 | 14 | 0.40 | 30 | 14.86 | 324 | 144 | 4.32 / 912.50 | 2 | 2 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.64 | 24 | 14.83 | 479 | 170 | 0.17 / 904.12 | 2 | 2 |
2 | 7 | 2004.24 | 42 | 14.12 | 3032 | 1798 | 1.97 / 905.92 | 2 | 2 |
3 | 13 | 1471.92 | 20 | 14.26 | 2352 | 671 | 2.64 / 906.59 | 2 | 2 |
4 | 13 | 1059.80 | 20 | 14.39 | 1799 | 518 | 3.16 / 907.10 | 2 | 2 |
5 | 13 | 340.92 | 20 | 14.73 | 827 | 244 | 3.40 / 907.35 | 2 | 2 |
6 | 8 | -0.28 | 175 | 14.88 | 320 | 833 | 4.23 / 908.18 | 2 | 2 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.00 | 23 | 14.84 | 493 | 168 | 0.17 / 899.80 | 2 | 2 |
2 | 7 | 2002.04 | 42 | 14.12 | 3017 | 1789 | 1.96 / 901.59 | 2 | 2 |
3 | 13 | 1591.16 | 20 | 14.23 | 2509 | 714 | 2.67 / 902.31 | 2 | 2 |
4 | 13 | 1031.72 | 20 | 14.41 | 1769 | 510 | 3.18 / 902.82 | 2 | 2 |
5 | 13 | 450.92 | 20 | 14.67 | 983 | 288 | 3.47 / 903.11 | 2 | 2 |
6 | 8 | 0.60 | 175 | 14.87 | 323 | 841 | 4.31 / 903.95 | 2 | 2 |
Average= | 4.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.76 | 24 | 14.84 | 484 | 172 | 0.17 / 895.26 | 2 | 2 |
2 | 7 | 2002.48 | 42 | 14.12 | 3025 | 1794 | 1.97 / 897.05 | 2 | 2 |
3 | 13 | 1589.76 | 20 | 14.23 | 2494 | 710 | 2.68 / 897.76 | 2 | 2 |
4 | 13 | 1021.64 | 20 | 14.42 | 1756 | 506 | 3.18 / 898.27 | 2 | 2 |
5 | 13 | 448.32 | 20 | 14.67 | 977 | 287 | 3.47 / 898.55 | 2 | 2 |
6 | 13 | 16.08 | 20 | 14.91 | 354 | 106 | 3.57 / 898.66 | 2 | 2 |
7 | 8 | -0.12 | 175 | 14.87 | 320 | 833 | 4.41 / 899.49 | 2 | 3 |
8 | 14 | -0.12 | 30 | 14.86 | 323 | 144 | 4.55 / 899.64 | 2 | 8 |
Average= | 4.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.40 | 23 | 14.85 | 481 | 164 | 0.16 / 890.94 | 2 | 2 |
2 | 7 | 2002.00 | 42 | 14.13 | 3019 | 1792 | 1.96 / 892.74 | 2 | 2 |
3 | 13 | 1598.72 | 20 | 14.23 | 2510 | 714 | 2.67 / 893.45 | 2 | 2 |
4 | 13 | 1041.28 | 20 | 14.41 | 1773 | 511 | 3.18 / 893.96 | 2 | 2 |
5 | 13 | 465.48 | 20 | 14.67 | 996 | 292 | 3.47 / 894.25 | 2 | 2 |
6 | 8 | 0.12 | 175 | 14.89 | 319 | 831 | 4.30 / 895.08 | 2 | 4 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.36 | 23 | 14.85 | 465 | 159 | 0.16 / 886.66 | 2 | 2 |
2 | 3 | 1031.32 | 1 | 14.94 | 1869 | 28 | 0.19 / 886.69 | 2 | 2 |
3 | 7 | 2006.72 | 42 | 14.13 | 3010 | 1786 | 1.97 / 888.48 | 2 | 2 |
4 | 13 | 1596.08 | 20 | 14.23 | 2510 | 714 | 2.69 / 889.19 | 2 | 2 |
5 | 13 | 1046.32 | 20 | 14.41 | 1777 | 512 | 3.20 / 889.70 | 2 | 2 |
6 | 13 | 348.60 | 20 | 14.73 | 840 | 247 | 3.45 / 889.95 | 2 | 2 |
7 | 8 | 0.28 | 175 | 14.89 | 318 | 829 | 4.28 / 890.78 | 2 | 3 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.32 | 23 | 14.84 | 479 | 163 | 0.16 / 882.35 | 2 | 2 |
2 | 7 | 2003.12 | 42 | 14.13 | 3020 | 1792 | 1.96 / 884.14 | 2 | 2 |
3 | 13 | 1720.76 | 20 | 14.21 | 2669 | 759 | 2.71 / 884.90 | 2 | 2 |
4 | 13 | 1010.48 | 20 | 14.43 | 1733 | 500 | 3.21 / 885.40 | 2 | 2 |
5 | 13 | 433.80 | 20 | 14.69 | 951 | 279 | 3.49 / 885.68 | 2 | 2 |
6 | 8 | 0.08 | 175 | 14.88 | 317 | 825 | 4.32 / 886.50 | 2 | 5 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.96 | 23 | 14.85 | 488 | 167 | 0.17 / 877.98 | 2 | 2 |
2 | 7 | 2007.04 | 42 | 14.13 | 3007 | 1785 | 1.95 / 879.76 | 2 | 2 |
3 | 13 | 1601.32 | 20 | 14.23 | 2514 | 715 | 2.67 / 880.48 | 2 | 2 |
4 | 13 | 1037.80 | 20 | 14.41 | 1777 | 512 | 3.18 / 880.99 | 2 | 2 |
5 | 13 | 324.72 | 20 | 14.74 | 808 | 238 | 3.42 / 881.23 | 2 | 2 |
6 | 13 | 38.84 | 20 | 14.89 | 391 | 116 | 3.53 / 881.34 | 2 | 2 |
7 | 8 | -0.08 | 175 | 14.87 | 324 | 843 | 4.38 / 882.19 | 2 | 7 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.92 | 23 | 14.85 | 468 | 160 | 0.16 / 873.74 | 2 | 2 |
2 | 7 | 2004.08 | 42 | 14.12 | 3026 | 1795 | 1.95 / 875.53 | 2 | 2 |
3 | 13 | 1585.20 | 20 | 14.23 | 2494 | 710 | 2.66 / 876.24 | 2 | 2 |
4 | 13 | 1013.40 | 20 | 14.42 | 1739 | 502 | 3.17 / 876.74 | 2 | 2 |
5 | 13 | 304.12 | 20 | 14.76 | 775 | 229 | 3.39 / 876.97 | 2 | 2 |
6 | 8 | 0.48 | 175 | 14.89 | 321 | 836 | 4.23 / 877.81 | 2 | 4 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.16 | 23 | 14.85 | 479 | 164 | 0.16 / 869.06 | 2 | 2 |
2 | 5 | 1300.40 | 8 | 14.57 | 2222 | 259 | 0.42 / 869.32 | 2 | 2 |
3 | 7 | 2006.00 | 42 | 14.11 | 3033 | 1797 | 2.22 / 871.11 | 2 | 2 |
4 | 13 | 1599.84 | 20 | 14.22 | 2520 | 717 | 2.94 / 871.83 | 2 | 2 |
5 | 13 | 1030.88 | 20 | 14.41 | 1763 | 508 | 3.44 / 872.34 | 2 | 2 |
6 | 13 | 459.44 | 20 | 14.67 | 997 | 293 | 3.74 / 872.63 | 2 | 2 |
7 | 13 | 32.08 | 20 | 14.90 | 377 | 112 | 3.85 / 872.74 | 2 | 2 |
8 | 8 | 0.16 | 175 | 14.88 | 320 | 833 | 4.68 / 873.58 | 2 | 2 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.28 | 23 | 14.86 | 473 | 162 | 0.16 / 864.64 | 2 | 2 |
2 | 7 | 2003.92 | 42 | 14.13 | 3021 | 1793 | 1.95 / 866.44 | 2 | 2 |
3 | 13 | 1596.68 | 20 | 14.23 | 2511 | 715 | 2.67 / 867.15 | 2 | 2 |
4 | 13 | 1029.48 | 20 | 14.42 | 1770 | 510 | 3.18 / 867.66 | 2 | 2 |
5 | 13 | 444.96 | 20 | 14.68 | 977 | 287 | 3.47 / 867.95 | 2 | 2 |
6 | 13 | 30.84 | 20 | 14.90 | 377 | 112 | 3.58 / 868.06 | 2 | 2 |
7 | 8 | 0.08 | 175 | 14.88 | 320 | 833 | 4.41 / 868.89 | 2 | 5 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.76 | 24 | 14.85 | 483 | 172 | 0.17 / 860.06 | 2 | 2 |
2 | 3 | 951.16 | -1 | 15.34 | 0 | 0 | 0.00 / 860.06 | 2 | 2 |
3 | 5 | 1301.32 | 8 | 14.58 | 2214 | 258 | 0.43 / 860.32 | 2 | 2 |
4 | 7 | 2003.36 | 42 | 14.12 | 3011 | 1786 | 2.22 / 862.10 | 2 | 2 |
5 | 13 | 1728.04 | 20 | 14.19 | 2667 | 757 | 2.97 / 862.86 | 2 | 2 |
6 | 13 | 1016.96 | 20 | 14.43 | 1740 | 502 | 3.48 / 863.36 | 2 | 2 |
7 | 13 | 449.64 | 20 | 14.68 | 983 | 289 | 3.76 / 863.65 | 2 | 2 |
8 | 8 | 0.40 | 175 | 14.89 | 319 | 831 | 4.59 / 864.48 | 2 | 2 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.08 | 23 | 14.85 | 472 | 161 | 0.16 / 855.73 | 2 | 2 |
2 | 7 | 2004.36 | 42 | 14.13 | 3023 | 1794 | 1.96 / 857.53 | 2 | 2 |
3 | 13 | 1484.28 | 20 | 14.27 | 2370 | 676 | 2.63 / 858.20 | 2 | 2 |
4 | 13 | 944.24 | 20 | 14.46 | 1649 | 477 | 3.11 / 858.68 | 2 | 2 |
5 | 13 | 377.20 | 20 | 14.71 | 878 | 258 | 3.37 / 858.94 | 2 | 2 |
6 | 13 | 46.76 | 20 | 14.89 | 402 | 120 | 3.49 / 859.06 | 2 | 2 |
7 | 8 | 0.12 | 175 | 14.88 | 319 | 831 | 4.32 / 859.89 | 2 | 2 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.28 | 23 | 14.84 | 487 | 166 | 0.17 / 851.34 | 2 | 2 |
2 | 7 | 2002.48 | 42 | 14.13 | 3016 | 1790 | 1.96 / 853.13 | 2 | 2 |
3 | 13 | 1595.08 | 20 | 14.24 | 2508 | 714 | 2.67 / 853.84 | 2 | 2 |
4 | 13 | 1019.08 | 20 | 14.43 | 1750 | 505 | 3.18 / 854.34 | 2 | 2 |
5 | 13 | 442.72 | 20 | 14.69 | 970 | 285 | 3.46 / 854.63 | 2 | 2 |
6 | 13 | 30.12 | 20 | 14.91 | 378 | 113 | 3.57 / 854.74 | 2 | 2 |
7 | 8 | 0.16 | 175 | 14.88 | 318 | 828 | 4.40 / 855.57 | 2 | 3 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.44 | 23 | 14.86 | 478 | 163 | 0.16 / 846.89 | 2 | 2 |
2 | 7 | 2009.76 | 42 | 14.13 | 3022 | 1793 | 1.96 / 848.69 | 2 | 2 |
3 | 13 | 1601.04 | 20 | 14.24 | 2515 | 716 | 2.67 / 849.40 | 2 | 2 |
4 | 13 | 1035.12 | 20 | 14.42 | 1772 | 511 | 3.18 / 849.92 | 2 | 2 |
5 | 13 | 459.36 | 20 | 14.67 | 1000 | 293 | 3.48 / 850.21 | 2 | 2 |
6 | 13 | 31.48 | 20 | 14.90 | 382 | 114 | 3.59 / 850.32 | 2 | 2 |
7 | 8 | 0.20 | 175 | 14.88 | 325 | 846 | 4.44 / 851.17 | 2 | 2 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.12 | 23 | 14.86 | 472 | 161 | 0.16 / 842.44 | 2 | 2 |
2 | 7 | 2001.92 | 42 | 14.14 | 3016 | 1791 | 1.95 / 844.23 | 2 | 2 |
3 | 13 | 1725.96 | 20 | 14.21 | 2692 | 765 | 2.72 / 845.00 | 2 | 2 |
4 | 13 | 1008.08 | 20 | 14.43 | 1734 | 500 | 3.22 / 845.50 | 2 | 2 |
5 | 13 | 438.96 | 20 | 14.69 | 967 | 284 | 3.50 / 845.78 | 2 | 2 |
6 | 13 | 15.52 | 20 | 14.92 | 355 | 106 | 3.61 / 845.89 | 2 | 2 |
7 | 8 | 0.16 | 175 | 14.88 | 323 | 841 | 4.45 / 846.73 | 2 | 6 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.72 | 23 | 14.85 | 472 | 161 | 0.16 / 838.07 | 2 | 2 |
2 | 7 | 2005.76 | 42 | 14.13 | 3027 | 1796 | 1.96 / 839.87 | 2 | 2 |
3 | 13 | 1607.92 | 20 | 14.23 | 2528 | 719 | 2.68 / 840.59 | 2 | 2 |
4 | 13 | 1036.32 | 20 | 14.42 | 1779 | 513 | 3.19 / 841.10 | 2 | 2 |
5 | 13 | 328.88 | 20 | 14.75 | 813 | 240 | 3.43 / 841.34 | 2 | 2 |
6 | 13 | 20.76 | 20 | 14.92 | 361 | 108 | 3.54 / 841.45 | 2 | 2 |
7 | 8 | -0.08 | 175 | 14.89 | 320 | 834 | 4.37 / 842.28 | 2 | 9 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.12 | 23 | 14.85 | 479 | 164 | 0.16 / 833.63 | 2 | 2 |
2 | 7 | 2006.40 | 43 | 14.13 | 3013 | 1831 | 1.99 / 835.46 | 2 | 2 |
3 | 13 | 1594.56 | 20 | 14.24 | 2503 | 713 | 2.71 / 836.18 | 2 | 2 |
4 | 13 | 1024.40 | 20 | 14.43 | 1752 | 506 | 3.21 / 836.68 | 2 | 2 |
5 | 13 | 442.72 | 20 | 14.69 | 972 | 286 | 3.50 / 836.97 | 2 | 2 |
6 | 13 | 14.80 | 20 | 14.92 | 354 | 106 | 3.60 / 837.07 | 2 | 2 |
7 | 8 | 0.24 | 175 | 14.88 | 322 | 838 | 4.44 / 837.91 | 2 | 3 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.68 | 23 | 14.84 | 485 | 166 | 0.17 / 829.14 | 2 | 2 |
2 | 7 | 2002.88 | 42 | 14.14 | 3016 | 1791 | 1.96 / 830.94 | 2 | 2 |
3 | 13 | 1729.48 | 20 | 14.21 | 2676 | 761 | 2.72 / 831.70 | 2 | 2 |
4 | 13 | 1133.60 | 20 | 14.38 | 1898 | 546 | 3.26 / 832.24 | 2 | 2 |
5 | 13 | 421.04 | 20 | 14.70 | 946 | 278 | 3.54 / 832.52 | 2 | 2 |
6 | 13 | 28.76 | 20 | 14.91 | 377 | 112 | 3.65 / 832.63 | 2 | 2 |
7 | 8 | -0.20 | 175 | 14.88 | 321 | 836 | 4.49 / 833.47 | 2 | 2 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.32 | 23 | 14.85 | 485 | 166 | 0.17 / 824.77 | 2 | 2 |
2 | 7 | 2004.56 | 42 | 14.14 | 3023 | 1795 | 1.96 / 826.56 | 2 | 2 |
3 | 13 | 1597.08 | 20 | 14.24 | 2519 | 717 | 2.68 / 827.28 | 2 | 2 |
4 | 13 | 1031.88 | 20 | 14.42 | 1757 | 507 | 3.19 / 827.78 | 2 | 2 |
5 | 13 | 343.56 | 20 | 14.74 | 830 | 245 | 3.43 / 828.03 | 2 | 2 |
6 | 13 | 20.32 | 20 | 14.92 | 363 | 108 | 3.54 / 828.14 | 2 | 2 |
7 | 8 | 0.28 | 175 | 14.88 | 323 | 841 | 4.38 / 828.98 | 2 | 5 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.52 | 23 | 14.85 | 485 | 166 | 0.17 / 820.41 | 2 | 2 |
2 | 7 | 2001.88 | 42 | 14.14 | 3015 | 1791 | 1.96 / 822.20 | 2 | 2 |
3 | 13 | 1595.16 | 20 | 14.24 | 2496 | 711 | 2.67 / 822.91 | 2 | 2 |
4 | 13 | 1030.16 | 20 | 14.43 | 1750 | 505 | 3.17 / 823.41 | 2 | 2 |
5 | 13 | 321.48 | 20 | 14.75 | 796 | 235 | 3.41 / 823.65 | 2 | 2 |
6 | 13 | 35.60 | 20 | 14.91 | 384 | 115 | 3.52 / 823.76 | 2 | 2 |
7 | 8 | 0.12 | 175 | 14.88 | 321 | 836 | 4.36 / 824.60 | 2 | 4 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.56 | 23 | 14.85 | 477 | 163 | 0.16 / 815.89 | 2 | 2 |
2 | 5 | 1301.56 | 8 | 14.59 | 2209 | 258 | 0.42 / 816.14 | 2 | 2 |
3 | 7 | 2009.24 | 42 | 14.12 | 3018 | 1790 | 2.21 / 817.93 | 2 | 2 |
4 | 13 | 1609.00 | 20 | 14.23 | 2517 | 716 | 2.93 / 818.65 | 2 | 2 |
5 | 13 | 1043.68 | 20 | 14.42 | 1769 | 510 | 3.44 / 819.16 | 2 | 2 |
6 | 13 | 347.96 | 20 | 14.74 | 840 | 248 | 3.68 / 819.41 | 2 | 2 |
7 | 8 | -0.08 | 175 | 14.90 | 320 | 834 | 4.52 / 820.24 | 2 | 4 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.40 | 23 | 14.84 | 489 | 167 | 0.17 / 811.57 | 2 | 2 |
2 | 7 | 2004.76 | 42 | 14.14 | 3007 | 1786 | 1.95 / 813.36 | 2 | 2 |
3 | 13 | 1597.88 | 20 | 14.24 | 2514 | 716 | 2.67 / 814.08 | 2 | 2 |
4 | 13 | 1035.24 | 20 | 14.43 | 1770 | 511 | 3.18 / 814.59 | 2 | 2 |
5 | 13 | 451.72 | 20 | 14.69 | 985 | 289 | 3.47 / 814.88 | 2 | 2 |
6 | 8 | 0.36 | 175 | 14.89 | 325 | 847 | 4.32 / 815.72 | 2 | 2 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.16 | 23 | 14.84 | 479 | 163 | 0.16 / 806.89 | 2 | 2 |
2 | 5 | 1303.52 | 8 | 14.60 | 2217 | 259 | 0.42 / 807.15 | 2 | 2 |
3 | 7 | 2006.08 | 42 | 14.13 | 3028 | 1797 | 2.22 / 808.95 | 2 | 2 |
4 | 13 | 1596.56 | 20 | 14.23 | 2515 | 716 | 2.94 / 809.66 | 2 | 2 |
5 | 13 | 1037.00 | 20 | 14.43 | 1774 | 512 | 3.45 / 810.17 | 2 | 2 |
6 | 13 | 454.52 | 20 | 14.69 | 981 | 288 | 3.74 / 810.46 | 2 | 2 |
7 | 13 | 30.88 | 20 | 14.92 | 376 | 112 | 3.85 / 810.57 | 2 | 2 |
8 | 8 | 0.12 | 175 | 14.89 | 320 | 834 | 4.68 / 811.41 | 2 | 2 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.52 | 23 | 14.85 | 484 | 165 | 0.17 / 802.49 | 2 | 2 |
2 | 7 | 2005.24 | 42 | 14.14 | 3009 | 1787 | 1.95 / 804.27 | 2 | 2 |
3 | 13 | 1592.80 | 20 | 14.25 | 2503 | 713 | 2.67 / 804.99 | 2 | 2 |
4 | 13 | 1027.20 | 20 | 14.44 | 1753 | 506 | 3.17 / 805.49 | 2 | 2 |
5 | 13 | 452.20 | 20 | 14.69 | 981 | 288 | 3.46 / 805.78 | 2 | 2 |
6 | 13 | 30.04 | 20 | 14.92 | 374 | 112 | 3.57 / 805.89 | 2 | 2 |
7 | 8 | 0.04 | 175 | 14.89 | 320 | 834 | 4.41 / 806.73 | 2 | 4 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.76 | 23 | 14.85 | 488 | 167 | 0.17 / 798.23 | 2 | 2 |
2 | 7 | 2003.20 | 42 | 14.14 | 3009 | 1787 | 1.95 / 800.02 | 2 | 2 |
3 | 13 | 1599.72 | 20 | 14.25 | 2508 | 715 | 2.67 / 800.73 | 2 | 2 |
4 | 13 | 1032.08 | 20 | 14.43 | 1764 | 509 | 3.18 / 801.24 | 2 | 2 |
5 | 13 | 329.52 | 20 | 14.76 | 815 | 241 | 3.42 / 801.48 | 2 | 2 |
6 | 8 | 0.08 | 175 | 14.89 | 322 | 839 | 4.26 / 802.32 | 2 | 2 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.64 | 22 | 14.84 | 491 | 160 | 0.16 / 793.91 | 2 | 2 |
2 | 7 | 2008.56 | 42 | 14.14 | 3025 | 1796 | 1.96 / 795.71 | 2 | 2 |
3 | 13 | 1594.60 | 20 | 14.25 | 2507 | 714 | 2.67 / 796.42 | 2 | 2 |
4 | 13 | 1031.52 | 20 | 14.43 | 1765 | 509 | 3.18 / 796.93 | 2 | 2 |
5 | 13 | 454.36 | 20 | 14.69 | 987 | 290 | 3.47 / 797.22 | 2 | 2 |
6 | 8 | 0.08 | 175 | 14.89 | 324 | 844 | 4.31 / 798.06 | 2 | 3 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.64 | 23 | 14.85 | 475 | 162 | 0.16 / 789.63 | 2 | 2 |
2 | 7 | 2002.08 | 42 | 14.15 | 3011 | 1789 | 1.95 / 791.41 | 2 | 2 |
3 | 13 | 1602.92 | 20 | 14.25 | 2512 | 716 | 2.67 / 792.13 | 2 | 2 |
4 | 13 | 914.40 | 20 | 14.48 | 1604 | 465 | 3.13 / 792.60 | 2 | 2 |
5 | 13 | 489.60 | 20 | 14.67 | 1035 | 304 | 3.44 / 792.90 | 2 | 2 |
6 | 8 | 0.28 | 175 | 14.89 | 326 | 849 | 4.29 / 793.75 | 2 | 2 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.84 | 23 | 14.84 | 487 | 166 | 0.17 / 785.28 | 2 | 2 |
2 | 7 | 2004.52 | 42 | 14.15 | 3003 | 1785 | 1.95 / 787.06 | 2 | 2 |
3 | 13 | 1588.28 | 20 | 14.27 | 2491 | 711 | 2.66 / 787.78 | 2 | 2 |
4 | 13 | 1018.00 | 20 | 14.44 | 1740 | 503 | 3.16 / 788.28 | 2 | 2 |
5 | 13 | 302.72 | 20 | 14.78 | 769 | 227 | 3.39 / 788.51 | 2 | 2 |
6 | 13 | 13.84 | 20 | 14.93 | 353 | 105 | 3.50 / 788.61 | 2 | 2 |
7 | 8 | 0.00 | 175 | 14.89 | 327 | 852 | 4.35 / 789.46 | 2 | 2 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.32 | 23 | 14.84 | 492 | 168 | 0.17 / 780.92 | 2 | 2 |
2 | 7 | 2002.40 | 42 | 14.15 | 3005 | 1786 | 1.95 / 782.71 | 2 | 2 |
3 | 13 | 1590.12 | 20 | 14.26 | 2494 | 711 | 2.67 / 783.42 | 2 | 2 |
4 | 13 | 1026.84 | 20 | 14.44 | 1739 | 502 | 3.17 / 783.92 | 2 | 2 |
5 | 13 | 323.80 | 20 | 14.77 | 804 | 238 | 3.40 / 784.16 | 2 | 2 |
6 | 13 | 17.96 | 20 | 14.93 | 363 | 108 | 3.51 / 784.26 | 2 | 2 |
7 | 8 | 0.08 | 175 | 14.89 | 326 | 849 | 4.36 / 785.11 | 2 | 3 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.08 | 23 | 14.84 | 489 | 167 | 0.17 / 776.35 | 2 | 2 |
2 | 5 | 1304.00 | 8 | 14.59 | 2201 | 257 | 0.42 / 776.61 | 2 | 2 |
3 | 7 | 2007.28 | 42 | 14.13 | 3016 | 1790 | 2.21 / 778.40 | 2 | 2 |
4 | 13 | 1596.60 | 20 | 14.24 | 2498 | 711 | 2.93 / 779.11 | 2 | 2 |
5 | 13 | 1029.20 | 20 | 14.43 | 1754 | 506 | 3.43 / 779.62 | 2 | 2 |
6 | 13 | 445.28 | 20 | 14.70 | 971 | 285 | 3.72 / 779.90 | 2 | 2 |
7 | 8 | 0.28 | 175 | 14.89 | 326 | 849 | 4.57 / 780.75 | 2 | 5 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.08 | 23 | 14.85 | 491 | 168 | 0.17 / 771.90 | 2 | 2 |
2 | 7 | 2005.44 | 43 | 14.15 | 3002 | 1827 | 1.99 / 773.73 | 2 | 2 |
3 | 13 | 1597.44 | 20 | 14.25 | 2519 | 718 | 2.71 / 774.44 | 2 | 2 |
4 | 13 | 1031.76 | 20 | 14.43 | 1759 | 508 | 3.22 / 774.95 | 2 | 2 |
5 | 13 | 320.20 | 20 | 14.77 | 798 | 236 | 3.46 / 775.19 | 2 | 2 |
6 | 8 | -0.04 | 175 | 14.90 | 326 | 850 | 4.31 / 776.04 | 2 | 2 |
7 | 14 | -0.04 | 30 | 14.88 | 329 | 147 | 4.45 / 776.19 | 2 | 3 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.20 | 23 | 14.85 | 487 | 166 | 0.17 / 767.66 | 2 | 2 |
2 | 7 | 2005.76 | 42 | 14.15 | 3000 | 1783 | 1.95 / 769.44 | 2 | 2 |
3 | 13 | 1596.16 | 20 | 14.26 | 2482 | 708 | 2.66 / 770.15 | 2 | 2 |
4 | 13 | 1021.96 | 20 | 14.44 | 1746 | 504 | 3.16 / 770.65 | 2 | 2 |
5 | 13 | 327.12 | 20 | 14.77 | 802 | 237 | 3.40 / 770.89 | 2 | 2 |
6 | 8 | 0.36 | 175 | 14.90 | 324 | 845 | 4.24 / 771.73 | 2 | 6 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.68 | 22 | 14.85 | 487 | 159 | 0.16 / 763.33 | 2 | 2 |
2 | 7 | 2005.20 | 42 | 14.16 | 2971 | 1767 | 1.93 / 765.10 | 2 | 2 |
3 | 13 | 1731.52 | 20 | 14.22 | 2667 | 758 | 2.68 / 765.86 | 2 | 2 |
4 | 13 | 1020.84 | 20 | 14.44 | 1744 | 504 | 3.19 / 766.36 | 2 | 2 |
5 | 13 | 447.52 | 20 | 14.70 | 975 | 287 | 3.47 / 766.65 | 2 | 2 |
6 | 8 | -0.08 | 175 | 14.90 | 323 | 842 | 4.32 / 767.49 | 2 | 2 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.32 | 23 | 14.84 | 495 | 169 | 0.17 / 758.97 | 2 | 2 |
2 | 7 | 2002.36 | 42 | 14.16 | 2995 | 1781 | 1.95 / 760.75 | 2 | 2 |
3 | 13 | 1727.64 | 20 | 14.23 | 2667 | 759 | 2.71 / 761.51 | 2 | 2 |
4 | 13 | 1138.64 | 20 | 14.40 | 1884 | 543 | 3.25 / 762.05 | 2 | 2 |
5 | 13 | 417.48 | 20 | 14.72 | 939 | 276 | 3.53 / 762.33 | 2 | 2 |
6 | 8 | 0.24 | 175 | 14.90 | 324 | 845 | 4.37 / 763.17 | 2 | 2 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.60 | 23 | 14.86 | 484 | 165 | 0.17 / 754.55 | 2 | 2 |
2 | 7 | 2003.24 | 42 | 14.15 | 3003 | 1785 | 1.95 / 756.33 | 2 | 2 |
3 | 13 | 1596.28 | 20 | 14.26 | 2497 | 712 | 2.66 / 757.04 | 2 | 2 |
4 | 13 | 1030.96 | 20 | 14.44 | 1767 | 510 | 3.17 / 757.55 | 2 | 2 |
5 | 13 | 452.60 | 20 | 14.69 | 989 | 291 | 3.46 / 757.84 | 2 | 2 |
6 | 13 | 33.72 | 20 | 14.92 | 378 | 113 | 3.58 / 757.96 | 2 | 2 |
7 | 8 | 0.04 | 175 | 14.89 | 323 | 842 | 4.42 / 758.80 | 2 | 3 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.84 | 22 | 14.87 | 478 | 156 | 0.16 / 750.24 | 2 | 2 |
2 | 7 | 2005.20 | 42 | 14.15 | 3014 | 1791 | 1.95 / 752.03 | 2 | 2 |
3 | 13 | 1591.36 | 20 | 14.26 | 2494 | 711 | 2.66 / 752.74 | 2 | 2 |
4 | 13 | 1029.68 | 20 | 14.45 | 1757 | 508 | 3.17 / 753.25 | 2 | 2 |
5 | 13 | 450.36 | 20 | 14.70 | 981 | 288 | 3.46 / 753.54 | 2 | 2 |
6 | 8 | 0.04 | 175 | 14.90 | 323 | 842 | 4.30 / 754.38 | 2 | 2 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.60 | 23 | 14.86 | 485 | 166 | 0.17 / 745.95 | 2 | 2 |
2 | 3 | 968.04 | -1 | 15.36 | 0 | 0 | 0.00 / 745.95 | 2 | 2 |
3 | 7 | 2001.72 | 42 | 14.15 | 3016 | 1792 | 1.96 / 747.75 | 2 | 2 |
4 | 13 | 1731.80 | 20 | 14.22 | 2690 | 765 | 2.72 / 748.51 | 2 | 2 |
5 | 13 | 1014.96 | 20 | 14.45 | 1741 | 503 | 3.23 / 749.02 | 2 | 2 |
6 | 13 | 311.68 | 20 | 14.78 | 784 | 232 | 3.46 / 749.25 | 2 | 2 |
7 | 8 | 0.12 | 175 | 14.91 | 321 | 838 | 4.30 / 750.08 | 2 | 4 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.24 | 22 | 14.87 | 479 | 157 | 0.16 / 741.63 | 2 | 2 |
2 | 3 | 1053.28 | 1 | 14.87 | 1913 | 28 | 0.19 / 741.66 | 2 | 2 |
3 | 7 | 2004.92 | 42 | 14.14 | 3016 | 1791 | 1.98 / 743.45 | 2 | 2 |
4 | 13 | 1589.20 | 20 | 14.26 | 2499 | 713 | 2.69 / 744.16 | 2 | 2 |
5 | 13 | 1016.68 | 20 | 14.45 | 1741 | 503 | 3.19 / 744.67 | 2 | 2 |
6 | 13 | 427.76 | 20 | 14.71 | 954 | 281 | 3.47 / 744.95 | 2 | 2 |
7 | 8 | 0.20 | 175 | 14.90 | 323 | 842 | 4.32 / 745.79 | 2 | 2 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.88 | 22 | 14.87 | 482 | 158 | 0.16 / 737.33 | 2 | 2 |
2 | 7 | 2005.84 | 42 | 14.15 | 3000 | 1783 | 1.94 / 739.11 | 2 | 2 |
3 | 13 | 1607.20 | 20 | 14.26 | 2517 | 718 | 2.66 / 739.83 | 2 | 2 |
4 | 13 | 1045.16 | 20 | 14.44 | 1779 | 514 | 3.17 / 740.34 | 2 | 2 |
5 | 13 | 461.32 | 20 | 14.70 | 997 | 293 | 3.47 / 740.64 | 2 | 2 |
6 | 8 | -0.04 | 175 | 14.91 | 321 | 838 | 4.30 / 741.47 | 2 | 2 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.44 | 23 | 14.87 | 479 | 164 | 0.16 / 733.08 | 2 | 2 |
2 | 3 | 959.08 | -1 | 15.36 | 0 | 0 | 0.00 / 733.08 | 2 | 2 |
3 | 7 | 2003.88 | 42 | 14.15 | 3012 | 1790 | 1.95 / 734.87 | 2 | 2 |
4 | 13 | 1597.72 | 20 | 14.26 | 2515 | 717 | 2.67 / 735.59 | 2 | 2 |
5 | 13 | 1023.04 | 20 | 14.45 | 1760 | 509 | 3.18 / 736.10 | 2 | 2 |
6 | 13 | 313.08 | 20 | 14.78 | 790 | 234 | 3.41 / 736.33 | 2 | 2 |
7 | 8 | 0.44 | 175 | 14.91 | 322 | 840 | 4.25 / 737.17 | 2 | 4 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.44 | 22 | 14.87 | 484 | 158 | 0.16 / 728.71 | 2 | 2 |
2 | 7 | 2002.80 | 42 | 14.15 | 3017 | 1793 | 1.95 / 730.50 | 2 | 2 |
3 | 13 | 1592.92 | 20 | 14.26 | 2503 | 714 | 2.67 / 731.22 | 2 | 2 |
4 | 13 | 1030.56 | 20 | 14.44 | 1762 | 509 | 3.17 / 731.73 | 2 | 2 |
5 | 13 | 323.68 | 20 | 14.77 | 805 | 238 | 3.41 / 731.96 | 2 | 2 |
6 | 13 | 40.52 | 20 | 14.93 | 392 | 117 | 3.53 / 732.08 | 2 | 2 |
7 | 8 | 0.04 | 175 | 14.90 | 321 | 837 | 4.37 / 732.92 | 2 | 3 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.84 | 22 | 14.88 | 472 | 155 | 0.15 / 724.36 | 2 | 2 |
2 | 7 | 2004.76 | 42 | 14.15 | 3019 | 1794 | 1.95 / 726.16 | 2 | 2 |
3 | 13 | 1596.28 | 20 | 14.27 | 2512 | 717 | 2.67 / 726.87 | 2 | 2 |
4 | 13 | 1163.60 | 20 | 14.39 | 1936 | 557 | 3.22 / 727.43 | 2 | 2 |
5 | 13 | 428.80 | 20 | 14.71 | 956 | 281 | 3.50 / 727.71 | 2 | 2 |
6 | 8 | 0.08 | 175 | 14.91 | 322 | 840 | 4.34 / 728.55 | 2 | 4 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.92 | 22 | 14.88 | 481 | 157 | 0.16 / 720.24 | 2 | 2 |
2 | 7 | 2006.84 | 42 | 14.15 | 3024 | 1797 | 1.95 / 722.03 | 2 | 2 |
3 | 13 | 1469.88 | 20 | 14.30 | 2340 | 669 | 2.62 / 722.70 | 2 | 2 |
4 | 13 | 930.88 | 20 | 14.48 | 1627 | 471 | 3.10 / 723.18 | 2 | 2 |
5 | 13 | 244.76 | 20 | 14.81 | 692 | 205 | 3.30 / 723.38 | 2 | 2 |
6 | 8 | 0.20 | 175 | 14.91 | 317 | 827 | 4.13 / 724.21 | 2 | 3 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.12 | 22 | 14.88 | 479 | 157 | 0.16 / 715.99 | 2 | 2 |
2 | 3 | 1021.64 | 1 | 15.02 | 1880 | 28 | 0.19 / 716.02 | 2 | 2 |
3 | 7 | 2003.84 | 42 | 14.15 | 3011 | 1789 | 1.97 / 717.81 | 2 | 2 |
4 | 13 | 1582.28 | 20 | 14.26 | 2489 | 710 | 2.68 / 718.52 | 2 | 2 |
5 | 13 | 1021.68 | 20 | 14.45 | 1746 | 505 | 3.19 / 719.02 | 2 | 2 |
6 | 13 | 311.92 | 20 | 14.79 | 784 | 232 | 3.42 / 719.26 | 2 | 2 |
7 | 8 | 0.16 | 175 | 14.92 | 316 | 825 | 4.25 / 720.08 | 2 | 4 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.48 | 23 | 14.87 | 471 | 161 | 0.16 / 711.68 | 2 | 2 |
2 | 3 | 953.64 | -1 | 15.36 | 0 | 0 | 0.00 / 711.68 | 2 | 2 |
3 | 7 | 2006.00 | 42 | 14.15 | 3027 | 1799 | 1.96 / 713.48 | 2 | 2 |
4 | 13 | 1599.88 | 20 | 14.26 | 2524 | 720 | 2.68 / 714.20 | 2 | 2 |
5 | 13 | 1036.64 | 20 | 14.45 | 1762 | 509 | 3.19 / 714.71 | 2 | 2 |
6 | 13 | 453.88 | 20 | 14.70 | 986 | 290 | 3.48 / 715.00 | 2 | 2 |
7 | 8 | 0.20 | 175 | 14.92 | 320 | 836 | 4.31 / 715.83 | 2 | 3 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.48 | 22 | 14.88 | 478 | 156 | 0.16 / 707.24 | 2 | 2 |
2 | 3 | 1041.60 | 1 | 14.93 | 1886 | 28 | 0.18 / 707.27 | 2 | 2 |
3 | 7 | 2007.52 | 42 | 14.16 | 3025 | 1799 | 1.98 / 709.07 | 2 | 2 |
4 | 13 | 1604.76 | 20 | 14.26 | 2534 | 723 | 2.71 / 709.79 | 2 | 2 |
5 | 13 | 914.04 | 20 | 14.50 | 1607 | 466 | 3.17 / 710.26 | 2 | 2 |
6 | 13 | 496.40 | 20 | 14.68 | 1042 | 306 | 3.48 / 710.56 | 2 | 2 |
7 | 13 | 35.84 | 20 | 14.93 | 386 | 115 | 3.59 / 710.68 | 2 | 2 |
8 | 8 | 0.04 | 175 | 14.90 | 322 | 840 | 4.43 / 711.52 | 2 | 3 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.24 | 23 | 14.87 | 477 | 163 | 0.16 / 702.90 | 2 | 2 |
2 | 3 | 968.20 | -1 | 15.36 | 0 | 0 | 0.00 / 702.90 | 2 | 2 |
3 | 3 | 1018.40 | 1 | 15.05 | 1878 | 28 | 0.19 / 702.93 | 2 | 2 |
4 | 7 | 2004.16 | 42 | 14.16 | 3019 | 1795 | 1.99 / 704.73 | 2 | 2 |
5 | 13 | 1596.60 | 20 | 14.26 | 2511 | 716 | 2.70 / 705.44 | 2 | 2 |
6 | 13 | 1033.20 | 20 | 14.45 | 1766 | 510 | 3.21 / 705.95 | 2 | 2 |
7 | 13 | 460.32 | 20 | 14.71 | 995 | 293 | 3.51 / 706.25 | 2 | 2 |
8 | 8 | 0.16 | 175 | 14.92 | 322 | 841 | 4.35 / 707.09 | 2 | 4 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.00 | 22 | 14.88 | 480 | 157 | 0.16 / 698.50 | 2 | 2 |
2 | 7 | 2003.80 | 43 | 14.16 | 3012 | 1834 | 1.99 / 700.34 | 2 | 2 |
3 | 13 | 1596.28 | 20 | 14.26 | 2512 | 716 | 2.71 / 701.05 | 2 | 2 |
4 | 13 | 1021.56 | 20 | 14.45 | 1751 | 506 | 3.21 / 701.56 | 2 | 2 |
5 | 13 | 307.52 | 20 | 14.79 | 781 | 231 | 3.44 / 701.79 | 2 | 2 |
6 | 13 | 32.48 | 20 | 14.94 | 379 | 113 | 3.56 / 701.90 | 2 | 2 |
7 | 8 | 0.24 | 175 | 14.91 | 320 | 835 | 4.39 / 702.74 | 2 | 4 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.84 | 23 | 14.88 | 471 | 161 | 0.16 / 694.07 | 2 | 2 |
2 | 3 | 973.32 | -1 | 15.37 | 0 | 0 | 0.00 / 694.07 | 2 | 2 |
3 | 3 | 1029.44 | 1 | 15.02 | 1885 | 28 | 0.19 / 694.10 | 2 | 2 |
4 | 7 | 2005.20 | 42 | 14.15 | 3030 | 1801 | 1.99 / 695.90 | 2 | 2 |
5 | 13 | 1734.20 | 20 | 14.23 | 2691 | 766 | 2.76 / 696.67 | 2 | 2 |
6 | 13 | 1010.52 | 20 | 14.47 | 1728 | 500 | 3.26 / 697.17 | 2 | 2 |
7 | 13 | 308.44 | 20 | 14.79 | 778 | 230 | 3.49 / 697.40 | 2 | 2 |
8 | 13 | 33.48 | 20 | 14.94 | 378 | 113 | 3.60 / 697.51 | 2 | 2 |
9 | 8 | 0.12 | 175 | 14.91 | 320 | 835 | 4.43 / 698.35 | 2 | 3 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.52 | 23 | 14.88 | 466 | 159 | 0.16 / 689.48 | 2 | 2 |
2 | 3 | 971.60 | -1 | 15.37 | 0 | 0 | 0.00 / 689.48 | 2 | 2 |
3 | 3 | 1025.84 | 1 | 15.04 | 1855 | 28 | 0.19 / 689.51 | 2 | 2 |
4 | 5 | 1304.76 | 8 | 14.60 | 2209 | 258 | 0.45 / 689.76 | 2 | 2 |
5 | 7 | 2005.12 | 42 | 14.15 | 2995 | 1780 | 2.23 / 691.54 | 2 | 2 |
6 | 13 | 1594.00 | 20 | 14.26 | 2509 | 716 | 2.94 / 692.26 | 2 | 2 |
7 | 13 | 896.60 | 20 | 14.51 | 1576 | 457 | 3.40 / 692.72 | 2 | 2 |
8 | 13 | 336.60 | 20 | 14.78 | 818 | 242 | 3.64 / 692.96 | 2 | 2 |
9 | 13 | 38.12 | 20 | 14.93 | 390 | 116 | 3.76 / 693.08 | 2 | 2 |
10 | 8 | 0.08 | 175 | 14.91 | 321 | 838 | 4.59 / 693.91 | 2 | 3 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.56 | 23 | 14.88 | 485 | 166 | 0.17 / 685.07 | 2 | 2 |
2 | 7 | 2006.00 | 42 | 14.16 | 3014 | 1792 | 1.96 / 686.87 | 2 | 2 |
3 | 13 | 1595.48 | 20 | 14.27 | 2501 | 714 | 2.67 / 687.58 | 2 | 2 |
4 | 13 | 1025.88 | 20 | 14.46 | 1753 | 507 | 3.18 / 688.09 | 2 | 2 |
5 | 13 | 449.72 | 20 | 14.72 | 976 | 287 | 3.47 / 688.37 | 2 | 2 |
6 | 13 | 31.16 | 20 | 14.94 | 374 | 112 | 3.58 / 688.49 | 2 | 2 |
7 | 8 | 0.04 | 175 | 14.91 | 319 | 832 | 4.41 / 689.32 | 2 | 3 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.00 | 23 | 14.88 | 487 | 167 | 0.17 / 680.81 | 2 | 2 |
2 | 7 | 2004.72 | 42 | 14.16 | 3024 | 1798 | 1.97 / 682.60 | 2 | 2 |
3 | 13 | 1600.36 | 20 | 14.26 | 2513 | 717 | 2.68 / 683.32 | 2 | 2 |
4 | 13 | 1030.72 | 20 | 14.45 | 1755 | 507 | 3.19 / 683.83 | 2 | 2 |
5 | 13 | 325.52 | 20 | 14.78 | 807 | 239 | 3.43 / 684.07 | 2 | 2 |
6 | 8 | 0.20 | 175 | 14.92 | 322 | 841 | 4.27 / 684.91 | 2 | 4 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.44 | 23 | 14.88 | 479 | 164 | 0.16 / 676.49 | 2 | 2 |
2 | 7 | 2001.88 | 42 | 14.16 | 3017 | 1794 | 1.96 / 678.28 | 2 | 2 |
3 | 13 | 1587.52 | 20 | 14.27 | 2501 | 714 | 2.67 / 678.99 | 2 | 2 |
4 | 13 | 1036.12 | 20 | 14.45 | 1775 | 513 | 3.18 / 679.51 | 2 | 2 |
5 | 13 | 451.72 | 20 | 14.72 | 984 | 290 | 3.47 / 679.80 | 2 | 2 |
6 | 8 | 0.20 | 175 | 14.92 | 323 | 843 | 4.32 / 680.64 | 2 | 2 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.44 | 23 | 14.88 | 490 | 168 | 0.17 / 671.96 | 2 | 2 |
2 | 5 | 1300.72 | 8 | 14.62 | 2217 | 259 | 0.43 / 672.22 | 2 | 2 |
3 | 7 | 2004.72 | 42 | 14.15 | 3016 | 1792 | 2.22 / 674.01 | 2 | 2 |
4 | 13 | 1597.40 | 20 | 14.27 | 2514 | 717 | 2.94 / 674.73 | 2 | 2 |
5 | 13 | 1030.80 | 20 | 14.46 | 1758 | 508 | 3.45 / 675.24 | 2 | 2 |
6 | 13 | 320.52 | 20 | 14.79 | 800 | 237 | 3.68 / 675.47 | 2 | 2 |
7 | 8 | 0.16 | 175 | 14.92 | 325 | 849 | 4.53 / 676.32 | 2 | 2 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.96 | 23 | 14.89 | 482 | 165 | 0.17 / 667.62 | 2 | 2 |
2 | 7 | 2003.60 | 42 | 14.16 | 3015 | 1793 | 1.96 / 669.41 | 2 | 2 |
3 | 13 | 1463.48 | 20 | 14.31 | 2334 | 668 | 2.63 / 670.08 | 2 | 2 |
4 | 13 | 1043.28 | 20 | 14.44 | 1782 | 515 | 3.14 / 670.59 | 2 | 2 |
5 | 13 | 328.08 | 20 | 14.78 | 811 | 240 | 3.38 / 670.83 | 2 | 2 |
6 | 13 | 19.08 | 20 | 14.95 | 363 | 109 | 3.49 / 670.94 | 2 | 2 |
7 | 8 | -0.12 | 175 | 14.91 | 325 | 848 | 4.34 / 671.79 | 2 | 3 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.96 | 23 | 14.89 | 483 | 165 | 0.17 / 663.29 | 2 | 2 |
2 | 7 | 2003.44 | 42 | 14.17 | 3016 | 1795 | 1.96 / 665.08 | 2 | 2 |
3 | 13 | 1596.24 | 20 | 14.27 | 2508 | 716 | 2.68 / 665.80 | 2 | 2 |
4 | 13 | 1034.00 | 20 | 14.46 | 1765 | 510 | 3.19 / 666.31 | 2 | 2 |
5 | 13 | 464.00 | 20 | 14.72 | 1000 | 294 | 3.48 / 666.60 | 2 | 2 |
6 | 8 | 0.16 | 175 | 14.93 | 325 | 849 | 4.33 / 667.45 | 2 | 3 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.28 | 23 | 14.88 | 490 | 168 | 0.17 / 659.02 | 2 | 2 |
2 | 7 | 2006.28 | 42 | 14.17 | 3019 | 1797 | 1.96 / 660.82 | 2 | 2 |
3 | 13 | 1597.40 | 20 | 14.28 | 2507 | 716 | 2.68 / 661.53 | 2 | 2 |
4 | 13 | 1033.96 | 20 | 14.46 | 1762 | 510 | 3.19 / 662.04 | 2 | 2 |
5 | 13 | 318.36 | 20 | 14.80 | 797 | 236 | 3.43 / 662.28 | 2 | 2 |
6 | 8 | 0.48 | 175 | 14.93 | 324 | 847 | 4.27 / 663.12 | 2 | 3 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.76 | 23 | 14.88 | 482 | 165 | 0.16 / 654.74 | 2 | 2 |
2 | 7 | 2003.16 | 42 | 14.17 | 3014 | 1794 | 1.96 / 656.53 | 2 | 2 |
3 | 13 | 1603.80 | 20 | 14.27 | 2521 | 719 | 2.68 / 657.25 | 2 | 2 |
4 | 13 | 1038.92 | 20 | 14.46 | 1773 | 513 | 3.19 / 657.76 | 2 | 2 |
5 | 13 | 327.76 | 20 | 14.79 | 810 | 240 | 3.43 / 658.00 | 2 | 2 |
6 | 8 | 0.20 | 175 | 14.92 | 325 | 849 | 4.28 / 658.85 | 2 | 3 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.20 | 23 | 14.87 | 501 | 171 | 0.17 / 650.44 | 2 | 2 |
2 | 7 | 2007.16 | 42 | 14.17 | 3021 | 1798 | 1.97 / 652.24 | 2 | 2 |
3 | 13 | 1609.68 | 20 | 14.27 | 2527 | 721 | 2.69 / 652.96 | 2 | 2 |
4 | 13 | 1043.88 | 20 | 14.46 | 1769 | 512 | 3.20 / 653.47 | 2 | 2 |
5 | 13 | 336.72 | 20 | 14.79 | 822 | 243 | 3.45 / 653.72 | 2 | 2 |
6 | 8 | 0.16 | 175 | 14.93 | 327 | 854 | 4.30 / 654.57 | 2 | 3 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.00 | 23 | 14.87 | 494 | 169 | 0.17 / 646.14 | 2 | 2 |
2 | 7 | 2007.28 | 42 | 14.16 | 3025 | 1799 | 1.97 / 647.94 | 2 | 2 |
3 | 13 | 1603.84 | 20 | 14.28 | 2527 | 722 | 2.69 / 648.67 | 2 | 2 |
4 | 13 | 1034.32 | 20 | 14.46 | 1763 | 510 | 3.20 / 649.18 | 2 | 2 |
5 | 13 | 322.40 | 20 | 14.80 | 805 | 238 | 3.44 / 649.41 | 2 | 2 |
6 | 8 | 0.16 | 175 | 14.92 | 329 | 859 | 4.30 / 650.27 | 2 | 4 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.36 | 23 | 14.87 | 495 | 169 | 0.17 / 641.56 | 2 | 2 |
2 | 5 | 1301.24 | 8 | 14.61 | 2229 | 261 | 0.43 / 641.82 | 2 | 2 |
3 | 7 | 2004.56 | 42 | 14.14 | 3027 | 1798 | 2.23 / 643.61 | 2 | 2 |
4 | 13 | 1730.88 | 20 | 14.23 | 2677 | 762 | 2.99 / 644.38 | 2 | 2 |
5 | 13 | 1021.56 | 20 | 14.47 | 1747 | 506 | 3.49 / 644.88 | 2 | 2 |
6 | 13 | 306.88 | 20 | 14.80 | 786 | 233 | 3.73 / 645.11 | 2 | 2 |
7 | 8 | -0.12 | 175 | 14.93 | 330 | 862 | 4.59 / 645.98 | 2 | 2 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.48 | 23 | 14.87 | 490 | 168 | 0.17 / 637.27 | 2 | 2 |
2 | 7 | 2003.88 | 42 | 14.17 | 3012 | 1793 | 1.96 / 639.06 | 2 | 2 |
3 | 13 | 1587.64 | 20 | 14.29 | 2506 | 716 | 2.68 / 639.78 | 2 | 2 |
4 | 13 | 1030.08 | 20 | 14.47 | 1757 | 508 | 3.18 / 640.29 | 2 | 2 |
5 | 13 | 303.84 | 20 | 14.80 | 779 | 231 | 3.42 / 640.52 | 2 | 2 |
6 | 8 | 0.40 | 175 | 14.92 | 333 | 869 | 4.28 / 641.39 | 2 | 3 |
Average= | 4.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.96 | 23 | 14.87 | 503 | 172 | 0.17 / 632.84 | 2 | 2 |
2 | 7 | 2004.84 | 42 | 14.17 | 3013 | 1793 | 1.97 / 634.63 | 2 | 2 |
3 | 13 | 1586.72 | 20 | 14.28 | 2498 | 713 | 2.68 / 635.34 | 2 | 2 |
4 | 13 | 1016.84 | 20 | 14.47 | 1737 | 503 | 3.18 / 635.85 | 2 | 2 |
5 | 13 | 437.88 | 20 | 14.73 | 968 | 285 | 3.47 / 636.13 | 2 | 2 |
6 | 13 | 15.96 | 20 | 14.96 | 363 | 109 | 3.58 / 636.24 | 2 | 2 |
7 | 8 | -0.40 | 175 | 14.92 | 330 | 862 | 4.44 / 637.10 | 2 | 5 |
Average= | 4.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.32 | 23 | 14.87 | 495 | 169 | 0.17 / 628.45 | 2 | 2 |
2 | 7 | 2004.44 | 42 | 14.17 | 3005 | 1788 | 1.96 / 630.24 | 2 | 2 |
3 | 13 | 1599.28 | 20 | 14.28 | 2507 | 716 | 2.67 / 630.95 | 2 | 2 |
4 | 13 | 1033.00 | 20 | 14.46 | 1757 | 508 | 3.18 / 631.46 | 2 | 2 |
5 | 13 | 594.72 | 20 | 14.65 | 1173 | 344 | 3.53 / 631.80 | 2 | 2 |
6 | 8 | 0.32 | 175 | 14.92 | 330 | 862 | 4.39 / 632.66 | 2 | 2 |
Average= | 4.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.28 | 23 | 14.87 | 505 | 173 | 0.17 / 623.75 | 2 | 2 |
2 | 5 | 1307.24 | 8 | 14.60 | 2224 | 260 | 0.43 / 624.01 | 2 | 2 |
3 | 7 | 2001.88 | 42 | 14.15 | 3013 | 1791 | 2.22 / 625.80 | 2 | 2 |
4 | 13 | 1595.48 | 20 | 14.28 | 2515 | 718 | 2.94 / 626.52 | 2 | 2 |
5 | 13 | 1027.96 | 20 | 14.46 | 1760 | 509 | 3.45 / 627.03 | 2 | 2 |
6 | 13 | 441.84 | 20 | 14.73 | 970 | 286 | 3.74 / 627.31 | 2 | 2 |
7 | 13 | 14.36 | 20 | 14.96 | 359 | 107 | 3.84 / 627.42 | 2 | 2 |
8 | 8 | 0.08 | 175 | 14.92 | 328 | 856 | 4.70 / 628.28 | 2 | 2 |
Average= | 4.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.56 | 23 | 14.88 | 492 | 168 | 0.17 / 619.44 | 2 | 2 |
2 | 7 | 2004.24 | 42 | 14.18 | 3002 | 1788 | 1.96 / 621.23 | 2 | 2 |
3 | 13 | 1723.84 | 20 | 14.25 | 2666 | 760 | 2.72 / 621.99 | 2 | 2 |
4 | 13 | 998.68 | 20 | 14.49 | 1718 | 498 | 3.21 / 622.49 | 2 | 2 |
5 | 13 | 289.92 | 20 | 14.82 | 756 | 224 | 3.44 / 622.71 | 2 | 2 |
6 | 8 | 0.16 | 175 | 14.93 | 331 | 865 | 4.30 / 623.58 | 2 | 2 |
Average= | 4.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.56 | 23 | 14.87 | 499 | 171 | 0.17 / 615.11 | 2 | 2 |
2 | 7 | 2004.76 | 42 | 14.17 | 3013 | 1793 | 1.96 / 616.91 | 2 | 2 |
3 | 13 | 1587.64 | 20 | 14.29 | 2493 | 712 | 2.68 / 617.62 | 2 | 2 |
4 | 13 | 1021.16 | 20 | 14.47 | 1743 | 504 | 3.18 / 618.12 | 2 | 2 |
5 | 13 | 436.96 | 20 | 14.74 | 967 | 285 | 3.47 / 618.41 | 2 | 2 |
6 | 8 | -0.12 | 175 | 14.93 | 332 | 867 | 4.33 / 619.27 | 2 | 3 |
Average= | 4.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.48 | 23 | 14.87 | 498 | 170 | 0.17 / 610.76 | 2 | 2 |
2 | 7 | 2014.84 | 42 | 14.17 | 3028 | 1802 | 1.97 / 612.56 | 2 | 2 |
3 | 13 | 1605.36 | 20 | 14.29 | 2517 | 719 | 2.69 / 613.28 | 2 | 2 |
4 | 13 | 1171.36 | 20 | 14.41 | 1940 | 559 | 3.25 / 613.84 | 2 | 2 |
5 | 13 | 311.20 | 20 | 14.81 | 787 | 233 | 3.48 / 614.07 | 2 | 2 |
6 | 8 | 0.24 | 175 | 14.93 | 332 | 867 | 4.35 / 614.94 | 2 | 3 |
Average= | 4.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.40 | 23 | 14.88 | 488 | 167 | 0.17 / 606.17 | 2 | 2 |
2 | 5 | 1302.28 | 8 | 14.61 | 2209 | 258 | 0.43 / 606.43 | 2 | 2 |
3 | 7 | 2004.68 | 42 | 14.17 | 3008 | 1790 | 2.22 / 608.22 | 2 | 2 |
4 | 13 | 1606.84 | 20 | 14.28 | 2521 | 720 | 2.94 / 608.94 | 2 | 2 |
5 | 13 | 1031.52 | 20 | 14.47 | 1760 | 509 | 3.44 / 609.44 | 2 | 2 |
6 | 13 | 443.24 | 20 | 14.74 | 968 | 285 | 3.73 / 609.73 | 2 | 2 |
7 | 8 | 0.00 | 175 | 14.93 | 329 | 860 | 4.59 / 610.59 | 2 | 3 |
Average= | 4.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.92 | 23 | 14.88 | 497 | 170 | 0.17 / 601.84 | 2 | 2 |
2 | 7 | 2005.52 | 42 | 14.18 | 3011 | 1793 | 1.96 / 603.63 | 2 | 2 |
3 | 13 | 1600.44 | 20 | 14.29 | 2503 | 715 | 2.68 / 604.35 | 2 | 2 |
4 | 13 | 1032.40 | 20 | 14.47 | 1757 | 508 | 3.19 / 604.86 | 2 | 2 |
5 | 13 | 451.20 | 20 | 14.74 | 976 | 288 | 3.47 / 605.15 | 2 | 2 |
6 | 8 | 0.08 | 175 | 14.93 | 327 | 854 | 4.33 / 606.00 | 2 | 2 |
Average= | 4.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.96 | 23 | 14.88 | 493 | 169 | 0.17 / 597.47 | 2 | 2 |
2 | 7 | 2003.52 | 42 | 14.18 | 3005 | 1790 | 1.96 / 599.26 | 2 | 2 |
3 | 13 | 1594.28 | 20 | 14.30 | 2501 | 715 | 2.67 / 599.98 | 2 | 2 |
4 | 13 | 1015.72 | 20 | 14.49 | 1732 | 502 | 3.18 / 600.48 | 2 | 2 |
5 | 13 | 301.36 | 20 | 14.82 | 769 | 228 | 3.40 / 600.71 | 2 | 2 |
6 | 13 | 38.28 | 20 | 14.96 | 386 | 115 | 3.52 / 600.82 | 2 | 2 |
7 | 8 | 0.12 | 175 | 14.93 | 325 | 849 | 4.37 / 601.67 | 2 | 6 |
Average= | 4.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.96 | 22 | 14.89 | 497 | 163 | 0.16 / 592.88 | 2 | 2 |
2 | 5 | 1303.00 | 8 | 14.62 | 2219 | 260 | 0.42 / 593.14 | 2 | 2 |
3 | 7 | 2003.32 | 42 | 14.17 | 3000 | 1785 | 2.21 / 594.92 | 2 | 2 |
4 | 13 | 1601.40 | 20 | 14.29 | 2501 | 715 | 2.92 / 595.64 | 2 | 2 |
5 | 13 | 1034.32 | 20 | 14.47 | 1765 | 511 | 3.43 / 596.15 | 2 | 2 |
6 | 13 | 457.24 | 20 | 14.73 | 987 | 291 | 3.72 / 596.44 | 2 | 2 |
7 | 8 | 0.36 | 175 | 14.93 | 330 | 862 | 4.59 / 597.30 | 2 | 2 |
Average= | 4.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.60 | 22 | 14.88 | 490 | 160 | 0.16 / 588.61 | 2 | 2 |
2 | 7 | 2006.24 | 42 | 14.17 | 3013 | 1793 | 1.95 / 590.41 | 2 | 2 |
3 | 13 | 1591.04 | 20 | 14.30 | 2501 | 715 | 2.67 / 591.12 | 2 | 2 |
4 | 13 | 1018.52 | 20 | 14.48 | 1745 | 505 | 3.17 / 591.63 | 2 | 2 |
5 | 13 | 287.64 | 20 | 14.83 | 754 | 224 | 3.40 / 591.85 | 2 | 2 |
6 | 8 | -0.08 | 175 | 14.94 | 331 | 865 | 4.26 / 592.72 | 2 | 3 |
Average= | 4.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.04 | 23 | 14.88 | 493 | 169 | 0.17 / 584.02 | 2 | 2 |
2 | 3 | 971.28 | -1 | 15.39 | 0 | 0 | 0.00 / 584.02 | 2 | 2 |
3 | 3 | 1021.04 | 1 | 15.07 | 1872 | 28 | 0.20 / 584.05 | 2 | 2 |
4 | 7 | 2004.32 | 43 | 14.17 | 3003 | 1830 | 2.03 / 585.88 | 2 | 2 |
5 | 13 | 1591.40 | 20 | 14.29 | 2497 | 714 | 2.74 / 586.59 | 2 | 2 |
6 | 13 | 1023.84 | 20 | 14.48 | 1753 | 508 | 3.25 / 587.10 | 2 | 2 |
7 | 13 | 312.40 | 20 | 14.81 | 788 | 233 | 3.48 / 587.33 | 2 | 2 |
8 | 13 | 33.96 | 20 | 14.96 | 389 | 116 | 3.60 / 587.45 | 2 | 2 |
9 | 8 | -0.04 | 175 | 14.93 | 328 | 857 | 4.45 / 588.31 | 2 | 3 |
10 | 14 | -0.04 | 30 | 14.91 | 331 | 148 | 4.60 / 588.45 | 2 | 4 |
Average= | 4.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.08 | 22 | 14.90 | 489 | 160 | 0.16 / 579.35 | 2 | 2 |
2 | 5 | 1303.80 | 8 | 14.61 | 2218 | 259 | 0.42 / 579.61 | 2 | 2 |
3 | 7 | 2006.16 | 42 | 14.16 | 3004 | 1787 | 2.21 / 581.40 | 2 | 2 |
4 | 13 | 1605.48 | 20 | 14.28 | 2529 | 722 | 2.93 / 582.12 | 2 | 2 |
5 | 13 | 1041.76 | 20 | 14.47 | 1786 | 517 | 3.45 / 582.64 | 2 | 2 |
6 | 13 | 329.84 | 20 | 14.80 | 815 | 241 | 3.69 / 582.88 | 2 | 2 |
7 | 13 | 19.00 | 20 | 14.97 | 365 | 109 | 3.80 / 582.99 | 2 | 2 |
8 | 8 | 0.24 | 175 | 14.93 | 330 | 862 | 4.66 / 583.85 | 2 | 3 |
Average= | 4.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.84 | 22 | 14.90 | 485 | 159 | 0.16 / 575.18 | 2 | 2 |
2 | 7 | 2002.16 | 42 | 14.18 | 3003 | 1788 | 1.95 / 576.97 | 2 | 2 |
3 | 13 | 1585.64 | 20 | 14.30 | 2490 | 712 | 2.66 / 577.68 | 2 | 2 |
4 | 13 | 897.48 | 20 | 14.54 | 1586 | 461 | 3.12 / 578.14 | 2 | 2 |
5 | 13 | 216.76 | 20 | 14.87 | 653 | 194 | 3.32 / 578.33 | 2 | 2 |
6 | 8 | 0.16 | 175 | 14.94 | 328 | 858 | 4.17 / 579.19 | 2 | 3 |
Average= | 4.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.48 | 23 | 14.89 | 487 | 167 | 0.17 / 570.83 | 2 | 2 |
2 | 3 | 966.84 | -1 | 15.39 | 0 | 0 | 0.00 / 570.83 | 2 | 2 |
3 | 7 | 2007.08 | 43 | 14.18 | 3011 | 1836 | 2.00 / 572.67 | 2 | 2 |
4 | 13 | 1585.16 | 20 | 14.30 | 2488 | 712 | 2.71 / 573.38 | 2 | 2 |
5 | 13 | 1007.72 | 20 | 14.49 | 1725 | 500 | 3.21 / 573.88 | 2 | 2 |
6 | 13 | 423.40 | 20 | 14.75 | 944 | 278 | 3.49 / 574.16 | 2 | 2 |
7 | 8 | 0.28 | 175 | 14.94 | 329 | 860 | 4.35 / 575.02 | 2 | 4 |
Average= | 4.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.76 | 23 | 14.90 | 479 | 164 | 0.16 / 566.44 | 2 | 2 |
2 | 7 | 2005.52 | 42 | 14.18 | 3014 | 1795 | 1.96 / 568.23 | 2 | 2 |
3 | 13 | 1588.76 | 20 | 14.30 | 2489 | 712 | 2.67 / 568.94 | 2 | 2 |
4 | 13 | 1026.16 | 20 | 14.49 | 1747 | 506 | 3.18 / 569.45 | 2 | 2 |
5 | 13 | 331.64 | 20 | 14.80 | 818 | 242 | 3.42 / 569.69 | 2 | 2 |
6 | 13 | 18.68 | 20 | 14.97 | 365 | 109 | 3.53 / 569.80 | 2 | 2 |
7 | 8 | -0.04 | 175 | 14.93 | 332 | 867 | 4.40 / 570.67 | 2 | 4 |
Average= | 4.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.44 | 23 | 14.90 | 479 | 164 | 0.16 / 562.00 | 2 | 2 |
2 | 7 | 2002.36 | 42 | 14.19 | 3005 | 1791 | 1.96 / 563.79 | 2 | 2 |
3 | 13 | 1599.20 | 20 | 14.30 | 2506 | 717 | 2.67 / 564.51 | 2 | 2 |
4 | 13 | 1030.20 | 20 | 14.48 | 1753 | 508 | 3.18 / 565.01 | 2 | 2 |
5 | 13 | 453.04 | 20 | 14.74 | 985 | 290 | 3.47 / 565.30 | 2 | 2 |
6 | 13 | 19.76 | 20 | 14.98 | 365 | 109 | 3.58 / 565.41 | 2 | 2 |
7 | 8 | 0.40 | 175 | 14.94 | 328 | 858 | 4.44 / 566.27 | 2 | 3 |
Average= | 4.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.72 | 22 | 14.91 | 489 | 160 | 0.16 / 557.70 | 2 | 2 |
2 | 3 | 1029.80 | 1 | 15.01 | 1878 | 28 | 0.19 / 557.73 | 2 | 2 |
3 | 7 | 2003.44 | 43 | 14.17 | 3000 | 1828 | 2.02 / 559.56 | 2 | 2 |
4 | 13 | 1472.88 | 20 | 14.34 | 2329 | 668 | 2.68 / 560.23 | 2 | 2 |
5 | 13 | 1052.32 | 20 | 14.46 | 1776 | 514 | 3.20 / 560.74 | 2 | 2 |
6 | 13 | 328.16 | 20 | 14.80 | 814 | 241 | 3.44 / 560.98 | 2 | 2 |
7 | 8 | 0.04 | 175 | 14.94 | 326 | 852 | 4.29 / 561.83 | 2 | 3 |
Average= | 4.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.64 | 22 | 14.91 | 494 | 162 | 0.16 / 553.34 | 2 | 2 |
2 | 7 | 2002.44 | 42 | 14.19 | 2986 | 1780 | 1.94 / 555.12 | 2 | 2 |
3 | 13 | 1592.80 | 20 | 14.30 | 2504 | 716 | 2.66 / 555.83 | 2 | 2 |
4 | 13 | 1025.76 | 20 | 14.48 | 1744 | 505 | 3.16 / 556.34 | 2 | 2 |
5 | 13 | 311.20 | 20 | 14.82 | 785 | 233 | 3.40 / 556.57 | 2 | 2 |
6 | 13 | 35.28 | 20 | 14.97 | 385 | 115 | 3.51 / 556.69 | 2 | 2 |
7 | 8 | 0.24 | 175 | 14.94 | 327 | 855 | 4.37 / 557.54 | 2 | 4 |
Average= | 4.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.88 | 23 | 14.91 | 469 | 161 | 0.16 / 548.92 | 2 | 2 |
2 | 7 | 2006.40 | 42 | 14.18 | 3003 | 1788 | 1.95 / 550.71 | 2 | 2 |
3 | 13 | 1590.20 | 20 | 14.31 | 2477 | 709 | 2.66 / 551.42 | 2 | 2 |
4 | 13 | 1019.88 | 20 | 14.49 | 1737 | 503 | 3.16 / 551.92 | 2 | 2 |
5 | 13 | 441.64 | 20 | 14.75 | 967 | 285 | 3.45 / 552.21 | 2 | 2 |
6 | 13 | 30.36 | 20 | 14.97 | 380 | 114 | 3.56 / 552.32 | 2 | 2 |
7 | 8 | 0.08 | 175 | 14.94 | 327 | 855 | 4.42 / 553.18 | 2 | 6 |
Average= | 4.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.44 | 22 | 14.92 | 477 | 157 | 0.16 / 544.44 | 2 | 2 |
2 | 3 | 1046.44 | 1 | 14.94 | 1892 | 28 | 0.18 / 544.47 | 2 | 2 |
3 | 7 | 2005.40 | 42 | 14.18 | 3000 | 1787 | 1.97 / 546.26 | 2 | 2 |
4 | 13 | 1729.68 | 20 | 14.26 | 2665 | 760 | 2.73 / 547.02 | 2 | 2 |
5 | 13 | 1011.04 | 20 | 14.50 | 1732 | 502 | 3.23 / 547.52 | 2 | 2 |
6 | 13 | 434.56 | 20 | 14.76 | 958 | 283 | 3.52 / 547.80 | 2 | 2 |
7 | 13 | 28.08 | 20 | 14.98 | 375 | 112 | 3.63 / 547.92 | 2 | 2 |
8 | 8 | 0.00 | 175 | 14.94 | 323 | 844 | 4.47 / 548.76 | 2 | 5 |
Average= | 4.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.28 | 23 | 14.91 | 484 | 166 | 0.17 / 540.15 | 2 | 2 |
2 | 3 | 922.16 | -1 | 15.40 | 0 | 0 | 0.00 / 540.15 | 2 | 2 |
3 | 3 | 971.48 | -1 | 15.42 | 0 | 0 | 0.00 / 540.15 | 2 | 2 |
4 | 7 | 2006.36 | 43 | 14.18 | 3012 | 1837 | 2.00 / 541.99 | 2 | 2 |
5 | 13 | 1597.12 | 20 | 14.30 | 2511 | 718 | 2.72 / 542.70 | 2 | 2 |
6 | 13 | 1018.80 | 20 | 14.49 | 1741 | 505 | 3.23 / 543.21 | 2 | 2 |
7 | 13 | 298.32 | 20 | 14.83 | 772 | 229 | 3.45 / 543.44 | 2 | 2 |
8 | 8 | 0.36 | 175 | 14.96 | 325 | 851 | 4.31 / 544.29 | 2 | 4 |
Average= | 4.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.56 | 23 | 14.92 | 474 | 163 | 0.16 / 535.49 | 2 | 2 |
2 | 3 | 1020.20 | 1 | 15.06 | 1876 | 28 | 0.19 / 535.52 | 2 | 2 |
3 | 5 | 1302.56 | 8 | 14.62 | 2226 | 260 | 0.45 / 535.78 | 2 | 2 |
4 | 7 | 2005.80 | 42 | 14.17 | 3006 | 1789 | 2.24 / 537.57 | 2 | 2 |
5 | 13 | 1480.16 | 20 | 14.34 | 2338 | 671 | 2.91 / 538.24 | 2 | 2 |
6 | 13 | 1071.48 | 20 | 14.46 | 1822 | 527 | 3.44 / 538.77 | 2 | 2 |
7 | 13 | 349.96 | 20 | 14.80 | 840 | 249 | 3.69 / 539.02 | 2 | 2 |
8 | 13 | 45.20 | 20 | 14.96 | 403 | 121 | 3.81 / 539.14 | 2 | 2 |
9 | 8 | 0.00 | 175 | 14.94 | 324 | 847 | 4.65 / 539.98 | 2 | 3 |
Average= | 4.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.80 | 22 | 14.91 | 484 | 159 | 0.16 / 531.04 | 2 | 2 |
2 | 3 | 1024.36 | 1 | 15.04 | 1874 | 28 | 0.19 / 531.06 | 2 | 2 |
3 | 7 | 2004.92 | 42 | 14.19 | 3011 | 1794 | 1.98 / 532.86 | 2 | 2 |
4 | 13 | 1595.60 | 20 | 14.31 | 2509 | 718 | 2.70 / 533.58 | 2 | 2 |
5 | 13 | 1024.48 | 20 | 14.49 | 1741 | 505 | 3.20 / 534.08 | 2 | 2 |
6 | 13 | 437.72 | 20 | 14.75 | 965 | 285 | 3.49 / 534.37 | 2 | 2 |
7 | 13 | 28.08 | 20 | 14.98 | 375 | 112 | 3.60 / 534.48 | 2 | 2 |
8 | 8 | 0.16 | 175 | 14.95 | 325 | 850 | 4.45 / 535.33 | 2 | 4 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.44 | 23 | 14.91 | 476 | 163 | 0.16 / 526.65 | 2 | 2 |
2 | 3 | 958.88 | -1 | 15.40 | 0 | 0 | 0.00 / 526.65 | 2 | 2 |
3 | 7 | 2002.40 | 42 | 14.19 | 3005 | 1791 | 1.95 / 528.44 | 2 | 2 |
4 | 13 | 1596.40 | 20 | 14.31 | 2511 | 719 | 2.67 / 529.16 | 2 | 2 |
5 | 13 | 1031.16 | 20 | 14.49 | 1759 | 510 | 3.18 / 529.67 | 2 | 2 |
6 | 13 | 325.48 | 20 | 14.82 | 814 | 241 | 3.42 / 529.91 | 2 | 2 |
7 | 13 | 38.84 | 20 | 14.97 | 395 | 118 | 3.54 / 530.03 | 2 | 2 |
8 | 8 | 0.28 | 175 | 14.94 | 326 | 852 | 4.39 / 530.88 | 2 | 4 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.04 | 23 | 14.91 | 486 | 167 | 0.17 / 522.17 | 2 | 2 |
2 | 7 | 2005.12 | 42 | 14.19 | 3023 | 1802 | 1.97 / 523.97 | 2 | 2 |
3 | 13 | 1595.32 | 20 | 14.31 | 2504 | 717 | 2.68 / 524.69 | 2 | 2 |
4 | 13 | 1157.72 | 20 | 14.43 | 1927 | 556 | 3.24 / 525.24 | 2 | 2 |
5 | 13 | 412.80 | 20 | 14.77 | 935 | 276 | 3.52 / 525.52 | 2 | 2 |
6 | 13 | 24.84 | 20 | 14.98 | 370 | 111 | 3.63 / 525.63 | 2 | 2 |
7 | 8 | 0.04 | 175 | 14.95 | 326 | 853 | 4.48 / 526.48 | 2 | 3 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.92 | 23 | 14.91 | 476 | 163 | 0.16 / 517.82 | 2 | 2 |
2 | 7 | 2002.28 | 42 | 14.19 | 3007 | 1792 | 1.96 / 519.61 | 2 | 2 |
3 | 13 | 1467.00 | 20 | 14.35 | 2334 | 670 | 2.63 / 520.28 | 2 | 2 |
4 | 13 | 1048.20 | 20 | 14.48 | 1769 | 512 | 3.14 / 520.79 | 2 | 2 |
5 | 13 | 338.32 | 20 | 14.81 | 827 | 245 | 3.38 / 521.04 | 2 | 2 |
6 | 13 | 39.00 | 20 | 14.97 | 390 | 117 | 3.50 / 521.16 | 2 | 2 |
7 | 8 | 0.16 | 175 | 14.94 | 324 | 847 | 4.35 / 522.00 | 2 | 3 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.44 | 22 | 14.92 | 489 | 161 | 0.16 / 513.32 | 2 | 2 |
2 | 7 | 2002.72 | 42 | 14.19 | 3007 | 1792 | 1.95 / 515.11 | 2 | 2 |
3 | 13 | 1727.12 | 20 | 14.28 | 2667 | 762 | 2.71 / 515.87 | 2 | 2 |
4 | 13 | 1125.72 | 20 | 14.46 | 1880 | 544 | 3.26 / 516.42 | 2 | 2 |
5 | 13 | 386.32 | 20 | 14.79 | 891 | 264 | 3.52 / 516.68 | 2 | 2 |
6 | 13 | 49.20 | 20 | 14.97 | 408 | 122 | 3.64 / 516.80 | 2 | 2 |
7 | 8 | 0.04 | 175 | 14.95 | 326 | 853 | 4.50 / 517.66 | 2 | 3 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.44 | 22 | 14.91 | 491 | 161 | 0.16 / 509.05 | 2 | 2 |
2 | 7 | 2006.68 | 42 | 14.19 | 3013 | 1796 | 1.96 / 510.85 | 2 | 2 |
3 | 13 | 1599.00 | 20 | 14.31 | 2521 | 722 | 2.68 / 511.57 | 2 | 2 |
4 | 13 | 1031.88 | 20 | 14.50 | 1759 | 510 | 3.19 / 512.08 | 2 | 2 |
5 | 13 | 326.84 | 20 | 14.82 | 808 | 239 | 3.43 / 512.32 | 2 | 2 |
6 | 8 | 0.24 | 175 | 14.96 | 320 | 838 | 4.27 / 513.16 | 2 | 2 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.44 | 23 | 14.91 | 492 | 169 | 0.17 / 504.63 | 2 | 2 |
2 | 7 | 2005.00 | 42 | 14.18 | 3005 | 1790 | 1.96 / 506.42 | 2 | 2 |
3 | 13 | 1592.48 | 20 | 14.32 | 2498 | 715 | 2.67 / 507.14 | 2 | 2 |
4 | 13 | 1017.16 | 20 | 14.50 | 1738 | 504 | 3.18 / 507.64 | 2 | 2 |
5 | 13 | 439.08 | 20 | 14.76 | 962 | 284 | 3.46 / 507.93 | 2 | 2 |
6 | 13 | 29.24 | 20 | 14.98 | 380 | 114 | 3.58 / 508.04 | 2 | 2 |
7 | 8 | 0.08 | 175 | 14.95 | 326 | 853 | 4.43 / 508.89 | 2 | 2 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.64 | 23 | 14.91 | 495 | 170 | 0.17 / 500.04 | 2 | 2 |
2 | 5 | 1306.32 | 8 | 14.62 | 2217 | 259 | 0.43 / 500.30 | 2 | 2 |
3 | 7 | 2002.16 | 42 | 14.18 | 3009 | 1792 | 2.22 / 502.09 | 2 | 2 |
4 | 13 | 1586.16 | 20 | 14.32 | 2497 | 715 | 2.94 / 502.81 | 2 | 2 |
5 | 13 | 1021.80 | 20 | 14.49 | 1753 | 508 | 3.44 / 503.32 | 2 | 2 |
6 | 13 | 445.28 | 20 | 14.76 | 975 | 288 | 3.73 / 503.60 | 2 | 2 |
7 | 8 | 0.20 | 175 | 14.95 | 329 | 861 | 4.59 / 504.47 | 2 | 2 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.60 | 23 | 14.90 | 502 | 172 | 0.17 / 495.72 | 2 | 2 |
2 | 7 | 2003.92 | 42 | 14.19 | 3007 | 1792 | 1.96 / 497.51 | 2 | 2 |
3 | 13 | 1731.24 | 20 | 14.27 | 2681 | 765 | 2.73 / 498.28 | 2 | 2 |
4 | 13 | 1006.56 | 20 | 14.50 | 1734 | 503 | 3.23 / 498.78 | 2 | 2 |
5 | 13 | 300.28 | 20 | 14.84 | 778 | 231 | 3.46 / 499.01 | 2 | 2 |
6 | 8 | -0.04 | 175 | 14.96 | 329 | 861 | 4.32 / 499.87 | 2 | 2 |
Average= | 4.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.60 | 23 | 14.91 | 485 | 166 | 0.17 / 491.43 | 2 | 2 |
2 | 7 | 2002.32 | 42 | 14.19 | 3024 | 1802 | 1.97 / 493.24 | 2 | 2 |
3 | 13 | 1594.52 | 20 | 14.32 | 2505 | 717 | 2.69 / 493.95 | 2 | 2 |
4 | 13 | 1026.84 | 20 | 14.49 | 1756 | 509 | 3.19 / 494.46 | 2 | 2 |
5 | 13 | 312.24 | 20 | 14.83 | 782 | 232 | 3.43 / 494.69 | 2 | 2 |
6 | 8 | -0.04 | 175 | 14.96 | 326 | 853 | 4.28 / 495.55 | 2 | 3 |
Average= | 4.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.04 | 23 | 14.89 | 495 | 170 | 0.17 / 487.01 | 2 | 2 |
2 | 7 | 2005.84 | 42 | 14.20 | 3013 | 1797 | 1.97 / 488.81 | 2 | 2 |
3 | 13 | 1728.64 | 20 | 14.28 | 2680 | 765 | 2.73 / 489.57 | 2 | 2 |
4 | 13 | 1150.00 | 20 | 14.45 | 1915 | 553 | 3.29 / 490.13 | 2 | 2 |
5 | 13 | 423.48 | 20 | 14.78 | 950 | 281 | 3.57 / 490.41 | 2 | 2 |
6 | 8 | 0.28 | 175 | 14.96 | 329 | 861 | 4.43 / 491.27 | 2 | 2 |
Average= | 4.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.48 | 22 | 14.91 | 492 | 161 | 0.16 / 482.73 | 2 | 2 |
2 | 7 | 2003.92 | 43 | 14.19 | 3010 | 1837 | 2.00 / 484.56 | 2 | 2 |
3 | 13 | 1461.64 | 20 | 14.37 | 2330 | 670 | 2.67 / 485.23 | 2 | 2 |
4 | 13 | 1046.00 | 20 | 14.48 | 1771 | 513 | 3.18 / 485.74 | 2 | 2 |
5 | 13 | 323.08 | 20 | 14.83 | 801 | 238 | 3.42 / 485.98 | 2 | 2 |
6 | 8 | 0.16 | 175 | 14.95 | 328 | 858 | 4.28 / 486.84 | 2 | 2 |
Average= | 4.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.72 | 22 | 14.90 | 504 | 165 | 0.17 / 478.31 | 2 | 2 |
2 | 7 | 2003.24 | 42 | 14.20 | 3013 | 1797 | 1.96 / 480.11 | 2 | 2 |
3 | 13 | 1726.52 | 20 | 14.29 | 2672 | 764 | 2.73 / 480.87 | 2 | 2 |
4 | 13 | 996.16 | 20 | 14.52 | 1710 | 497 | 3.22 / 481.37 | 2 | 2 |
5 | 13 | 564.48 | 20 | 14.70 | 1140 | 335 | 3.56 / 481.70 | 2 | 2 |
6 | 8 | 1.20 | 175 | 14.96 | 329 | 861 | 4.42 / 482.56 | 2 | 4 |
Average= | 4.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.04 | 22 | 14.90 | 496 | 163 | 0.16 / 473.93 | 2 | 2 |
2 | 7 | 2006.16 | 42 | 14.20 | 3019 | 1801 | 1.96 / 475.73 | 2 | 2 |
3 | 13 | 1598.44 | 20 | 14.32 | 2523 | 723 | 2.69 / 476.45 | 2 | 2 |
4 | 13 | 1157.88 | 20 | 14.45 | 1921 | 555 | 3.24 / 477.01 | 2 | 2 |
5 | 13 | 420.32 | 20 | 14.78 | 940 | 278 | 3.52 / 477.28 | 2 | 2 |
6 | 8 | -0.08 | 175 | 14.96 | 329 | 861 | 4.38 / 478.14 | 2 | 8 |
Average= | 4.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.96 | 23 | 14.91 | 482 | 165 | 0.17 / 469.57 | 2 | 2 |
2 | 7 | 2002.64 | 42 | 14.19 | 3008 | 1793 | 1.96 / 471.37 | 2 | 2 |
3 | 13 | 1458.40 | 20 | 14.37 | 2332 | 670 | 2.63 / 472.04 | 2 | 2 |
4 | 13 | 1038.76 | 20 | 14.50 | 1759 | 510 | 3.14 / 472.55 | 2 | 2 |
5 | 13 | 328.04 | 20 | 14.83 | 809 | 240 | 3.38 / 472.79 | 2 | 2 |
6 | 13 | 36.96 | 20 | 14.98 | 394 | 118 | 3.50 / 472.90 | 2 | 2 |
7 | 8 | 0.24 | 175 | 14.95 | 329 | 861 | 4.36 / 473.76 | 2 | 3 |
Average= | 4.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.20 | 22 | 14.91 | 494 | 162 | 0.16 / 465.31 | 2 | 2 |
2 | 7 | 2003.72 | 42 | 14.20 | 3016 | 1799 | 1.96 / 467.11 | 2 | 2 |
3 | 13 | 1591.80 | 20 | 14.33 | 2499 | 716 | 2.68 / 467.83 | 2 | 2 |
4 | 13 | 1011.60 | 20 | 14.51 | 1722 | 500 | 3.18 / 468.33 | 2 | 2 |
5 | 13 | 294.80 | 20 | 14.85 | 760 | 226 | 3.40 / 468.55 | 2 | 2 |
6 | 8 | 0.12 | 175 | 14.96 | 327 | 856 | 4.26 / 469.41 | 2 | 3 |
Average= | 4.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.40 | 22 | 14.91 | 484 | 159 | 0.16 / 461.03 | 2 | 2 |
2 | 7 | 2003.44 | 42 | 14.20 | 3012 | 1796 | 1.96 / 462.83 | 2 | 2 |
3 | 13 | 1594.84 | 20 | 14.33 | 2504 | 718 | 2.67 / 463.55 | 2 | 2 |
4 | 13 | 1033.12 | 20 | 14.50 | 1759 | 510 | 3.18 / 464.06 | 2 | 2 |
5 | 13 | 322.92 | 20 | 14.84 | 798 | 237 | 3.42 / 464.29 | 2 | 2 |
6 | 8 | 0.36 | 175 | 14.96 | 327 | 856 | 4.28 / 465.15 | 2 | 2 |
Average= | 4.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.92 | 22 | 14.92 | 485 | 159 | 0.16 / 456.72 | 2 | 2 |
2 | 7 | 2001.36 | 42 | 14.21 | 3005 | 1793 | 1.95 / 458.51 | 2 | 2 |
3 | 13 | 1592.04 | 20 | 14.34 | 2492 | 715 | 2.67 / 459.23 | 2 | 2 |
4 | 13 | 1028.40 | 20 | 14.51 | 1747 | 507 | 3.17 / 459.74 | 2 | 2 |
5 | 13 | 442.16 | 20 | 14.77 | 964 | 285 | 3.46 / 460.02 | 2 | 2 |
6 | 8 | -0.24 | 175 | 14.96 | 326 | 853 | 4.31 / 460.87 | 2 | 3 |
Average= | 4.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.20 | 22 | 14.91 | 492 | 161 | 0.16 / 452.40 | 2 | 2 |
2 | 7 | 2003.32 | 42 | 14.20 | 3016 | 1799 | 1.96 / 454.20 | 2 | 2 |
3 | 13 | 1589.80 | 20 | 14.33 | 2500 | 716 | 2.68 / 454.91 | 2 | 2 |
4 | 13 | 1023.12 | 20 | 14.51 | 1746 | 507 | 3.18 / 455.42 | 2 | 2 |
5 | 13 | 433.00 | 20 | 14.78 | 950 | 281 | 3.46 / 455.70 | 2 | 2 |
6 | 8 | 0.20 | 175 | 14.96 | 329 | 861 | 4.33 / 456.56 | 2 | 2 |
Average= | 4.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.96 | 22 | 14.91 | 490 | 161 | 0.16 / 448.03 | 2 | 2 |
2 | 7 | 2004.08 | 42 | 14.20 | 3008 | 1794 | 1.95 / 449.82 | 2 | 2 |
3 | 13 | 1597.40 | 20 | 14.33 | 2499 | 716 | 2.67 / 450.54 | 2 | 2 |
4 | 13 | 1165.72 | 20 | 14.45 | 1929 | 557 | 3.23 / 451.10 | 2 | 2 |
5 | 13 | 425.20 | 20 | 14.78 | 943 | 279 | 3.51 / 451.37 | 2 | 2 |
6 | 8 | 0.32 | 175 | 14.96 | 329 | 861 | 4.37 / 452.24 | 2 | 3 |
Average= | 4.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.64 | 22 | 14.91 | 492 | 161 | 0.16 / 443.78 | 2 | 2 |
2 | 7 | 2005.00 | 42 | 14.20 | 3027 | 1805 | 1.97 / 445.58 | 2 | 2 |
3 | 13 | 1606.72 | 20 | 14.33 | 2504 | 718 | 2.68 / 446.30 | 2 | 2 |
4 | 13 | 1044.60 | 20 | 14.50 | 1771 | 514 | 3.20 / 446.81 | 2 | 2 |
5 | 13 | 202.44 | 20 | 14.91 | 629 | 188 | 3.39 / 447.00 | 2 | 2 |
6 | 8 | 0.28 | 175 | 14.97 | 331 | 867 | 4.25 / 447.87 | 2 | 3 |
Average= | 4.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.92 | 22 | 14.92 | 489 | 161 | 0.16 / 439.42 | 2 | 2 |
2 | 7 | 2003.56 | 42 | 14.21 | 3010 | 1796 | 1.96 / 441.21 | 2 | 2 |
3 | 13 | 1729.60 | 20 | 14.30 | 2670 | 764 | 2.72 / 441.98 | 2 | 2 |
4 | 13 | 1007.16 | 20 | 14.53 | 1724 | 501 | 3.22 / 442.48 | 2 | 2 |
5 | 13 | 427.28 | 20 | 14.78 | 948 | 280 | 3.50 / 442.76 | 2 | 2 |
6 | 8 | -0.16 | 175 | 14.97 | 327 | 857 | 4.36 / 443.61 | 2 | 2 |
Average= | 4.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.64 | 22 | 14.91 | 492 | 161 | 0.16 / 435.14 | 2 | 2 |
2 | 7 | 2003.80 | 42 | 14.21 | 3003 | 1792 | 1.95 / 436.93 | 2 | 2 |
3 | 13 | 1595.28 | 20 | 14.34 | 2505 | 718 | 2.67 / 437.65 | 2 | 2 |
4 | 13 | 1023.60 | 20 | 14.52 | 1744 | 506 | 3.18 / 438.16 | 2 | 2 |
5 | 13 | 322.48 | 20 | 14.84 | 798 | 237 | 3.42 / 438.39 | 2 | 2 |
6 | 8 | 0.24 | 175 | 14.97 | 329 | 862 | 4.28 / 439.26 | 2 | 5 |
Average= | 4.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.20 | 22 | 14.92 | 486 | 160 | 0.16 / 430.78 | 2 | 2 |
2 | 7 | 2003.84 | 43 | 14.20 | 3003 | 1834 | 1.99 / 432.61 | 2 | 2 |
3 | 13 | 1593.56 | 20 | 14.34 | 2505 | 718 | 2.71 / 433.33 | 2 | 2 |
4 | 13 | 1022.36 | 20 | 14.52 | 1739 | 505 | 3.22 / 433.84 | 2 | 2 |
5 | 13 | 447.32 | 20 | 14.77 | 970 | 287 | 3.50 / 434.12 | 2 | 2 |
6 | 8 | 0.24 | 175 | 14.97 | 327 | 857 | 4.36 / 434.98 | 2 | 3 |
Average= | 4.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.64 | 22 | 14.93 | 484 | 159 | 0.16 / 426.46 | 2 | 2 |
2 | 7 | 2004.84 | 42 | 14.21 | 3016 | 1800 | 1.96 / 428.26 | 2 | 2 |
3 | 13 | 1593.56 | 20 | 14.34 | 2497 | 716 | 2.68 / 428.97 | 2 | 2 |
4 | 13 | 1023.00 | 20 | 14.52 | 1744 | 506 | 3.18 / 429.48 | 2 | 2 |
5 | 13 | 442.04 | 20 | 14.78 | 966 | 286 | 3.47 / 429.76 | 2 | 2 |
6 | 8 | 0.28 | 175 | 14.97 | 326 | 854 | 4.32 / 430.62 | 2 | 4 |
Average= | 4.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.68 | 22 | 14.92 | 496 | 163 | 0.16 / 422.11 | 2 | 2 |
2 | 3 | 1028.92 | 1 | 15.04 | 1870 | 28 | 0.19 / 422.14 | 2 | 2 |
3 | 7 | 2004.68 | 42 | 14.21 | 3001 | 1791 | 1.98 / 423.93 | 2 | 2 |
4 | 13 | 1601.84 | 20 | 14.34 | 2505 | 718 | 2.70 / 424.65 | 2 | 2 |
5 | 13 | 1024.84 | 20 | 14.51 | 1748 | 507 | 3.21 / 425.16 | 2 | 2 |
6 | 13 | 435.92 | 20 | 14.78 | 957 | 283 | 3.49 / 425.44 | 2 | 2 |
7 | 8 | -0.12 | 175 | 14.97 | 327 | 857 | 4.35 / 426.30 | 2 | 3 |
Average= | 4.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.00 | 22 | 14.92 | 489 | 161 | 0.16 / 417.59 | 2 | 2 |
2 | 7 | 2006.36 | 42 | 14.21 | 2997 | 1789 | 1.95 / 419.38 | 2 | 2 |
3 | 13 | 1591.56 | 20 | 14.34 | 2499 | 717 | 2.67 / 420.09 | 2 | 2 |
4 | 13 | 1026.48 | 20 | 14.52 | 1751 | 508 | 3.17 / 420.60 | 2 | 2 |
5 | 13 | 310.44 | 20 | 14.85 | 783 | 233 | 3.41 / 420.83 | 2 | 2 |
6 | 13 | 37.80 | 20 | 15.00 | 389 | 117 | 3.52 / 420.95 | 2 | 2 |
7 | 8 | -0.04 | 175 | 14.97 | 325 | 851 | 4.38 / 421.80 | 2 | 5 |
8 | 14 | -0.04 | 30 | 14.94 | 330 | 148 | 4.52 / 421.95 | 2 | 4 |
Average= | 4.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.60 | 21 | 14.92 | 489 | 153 | 0.15 / 413.21 | 2 | 2 |
2 | 3 | 1022.64 | 1 | 15.06 | 1871 | 28 | 0.18 / 413.24 | 2 | 2 |
3 | 7 | 2001.92 | 42 | 14.21 | 2994 | 1787 | 1.97 / 415.03 | 2 | 2 |
4 | 13 | 1726.88 | 20 | 14.30 | 2669 | 763 | 2.73 / 415.79 | 2 | 2 |
5 | 13 | 1012.04 | 20 | 14.53 | 1722 | 500 | 3.23 / 416.29 | 2 | 2 |
6 | 13 | 439.96 | 20 | 14.79 | 963 | 285 | 3.52 / 416.58 | 2 | 2 |
7 | 8 | 0.32 | 175 | 14.97 | 325 | 851 | 4.37 / 417.43 | 2 | 2 |
Average= | 4.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.00 | 22 | 14.94 | 485 | 159 | 0.16 / 408.84 | 2 | 2 |
2 | 3 | 964.88 | -1 | 15.42 | 0 | 0 | 0.00 / 408.84 | 2 | 2 |
3 | 7 | 2001.56 | 42 | 14.21 | 3000 | 1790 | 1.95 / 410.63 | 2 | 2 |
4 | 13 | 1590.12 | 20 | 14.35 | 2494 | 716 | 2.67 / 411.35 | 2 | 2 |
5 | 13 | 1018.28 | 20 | 14.52 | 1733 | 503 | 3.17 / 411.85 | 2 | 2 |
6 | 13 | 310.12 | 20 | 14.85 | 782 | 232 | 3.40 / 412.08 | 2 | 2 |
7 | 13 | 33.24 | 20 | 15.00 | 384 | 115 | 3.52 / 412.20 | 2 | 2 |
8 | 8 | 0.08 | 175 | 14.97 | 328 | 859 | 4.38 / 413.06 | 2 | 3 |
Average= | 4.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.16 | 21 | 14.95 | 476 | 149 | 0.15 / 404.37 | 2 | 2 |
2 | 3 | 1046.36 | 1 | 14.96 | 1888 | 28 | 0.18 / 404.40 | 2 | 2 |
3 | 7 | 2003.44 | 42 | 14.22 | 2989 | 1785 | 1.96 / 406.18 | 2 | 2 |
4 | 13 | 1730.44 | 20 | 14.30 | 2680 | 766 | 2.73 / 406.95 | 2 | 2 |
5 | 13 | 1013.04 | 20 | 14.53 | 1737 | 505 | 3.23 / 407.45 | 2 | 2 |
6 | 13 | 308.44 | 20 | 14.86 | 782 | 232 | 3.47 / 407.69 | 2 | 2 |
7 | 8 | 0.28 | 175 | 14.98 | 324 | 849 | 4.32 / 408.54 | 2 | 2 |
8 | 14 | 0.28 | 30 | 14.96 | 329 | 148 | 4.46 / 408.68 | 2 | 3 |
Average= | 4.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.64 | 22 | 14.95 | 478 | 157 | 0.16 / 400.10 | 2 | 2 |
2 | 3 | 973.60 | -1 | 15.45 | 0 | 0 | 0.00 / 400.10 | 2 | 2 |
3 | 7 | 2004.76 | 43 | 14.21 | 2986 | 1825 | 1.98 / 401.93 | 2 | 2 |
4 | 13 | 1595.16 | 20 | 14.35 | 2500 | 717 | 2.70 / 402.64 | 2 | 2 |
5 | 13 | 1018.44 | 20 | 14.53 | 1736 | 504 | 3.20 / 403.15 | 2 | 2 |
6 | 13 | 300.08 | 20 | 14.86 | 767 | 228 | 3.43 / 403.38 | 2 | 2 |
7 | 8 | 0.04 | 175 | 14.98 | 322 | 844 | 4.28 / 404.22 | 2 | 2 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.64 | 21 | 14.94 | 482 | 151 | 0.15 / 395.81 | 2 | 2 |
2 | 3 | 1026.72 | 1 | 15.05 | 1865 | 28 | 0.18 / 395.84 | 2 | 2 |
3 | 7 | 2005.80 | 42 | 14.21 | 3004 | 1793 | 1.97 / 397.63 | 2 | 2 |
4 | 13 | 1595.64 | 20 | 14.35 | 2498 | 717 | 2.69 / 398.35 | 2 | 2 |
5 | 13 | 1033.08 | 20 | 14.52 | 1759 | 511 | 3.20 / 398.86 | 2 | 2 |
6 | 13 | 311.20 | 20 | 14.86 | 787 | 234 | 3.43 / 399.09 | 2 | 2 |
7 | 8 | 0.36 | 175 | 14.99 | 325 | 853 | 4.29 / 399.94 | 2 | 2 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.64 | 22 | 14.95 | 478 | 157 | 0.16 / 391.44 | 2 | 2 |
2 | 3 | 963.96 | -1 | 15.42 | 0 | 0 | 0.00 / 391.44 | 2 | 2 |
3 | 7 | 2003.64 | 42 | 14.22 | 2991 | 1786 | 1.94 / 393.23 | 2 | 2 |
4 | 13 | 1594.00 | 20 | 14.35 | 2506 | 719 | 2.66 / 393.95 | 2 | 2 |
5 | 13 | 1021.96 | 20 | 14.53 | 1738 | 505 | 3.17 / 394.45 | 2 | 2 |
6 | 13 | 315.12 | 20 | 14.85 | 791 | 235 | 3.40 / 394.69 | 2 | 2 |
7 | 13 | 40.88 | 20 | 15.00 | 392 | 118 | 3.52 / 394.81 | 2 | 2 |
8 | 8 | 0.12 | 175 | 14.97 | 325 | 851 | 4.37 / 395.66 | 2 | 2 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.32 | 21 | 14.95 | 474 | 149 | 0.15 / 387.06 | 2 | 2 |
2 | 3 | 1065.88 | 2 | 14.91 | 1900 | 57 | 0.21 / 387.12 | 2 | 2 |
3 | 7 | 2006.36 | 43 | 14.21 | 2986 | 1825 | 2.03 / 388.94 | 2 | 2 |
4 | 13 | 1583.20 | 20 | 14.35 | 2481 | 712 | 2.74 / 389.66 | 2 | 2 |
5 | 13 | 1003.80 | 20 | 14.54 | 1716 | 499 | 3.24 / 390.16 | 2 | 2 |
6 | 13 | 418.56 | 20 | 14.80 | 941 | 279 | 3.52 / 390.43 | 2 | 2 |
7 | 8 | 0.48 | 175 | 14.98 | 325 | 852 | 4.37 / 391.29 | 2 | 4 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.08 | 22 | 14.95 | 470 | 155 | 0.15 / 382.71 | 2 | 2 |
2 | 3 | 964.72 | -1 | 15.42 | 0 | 0 | 0.00 / 382.71 | 2 | 2 |
3 | 7 | 2001.92 | 42 | 14.21 | 2983 | 1780 | 1.93 / 384.49 | 2 | 2 |
4 | 13 | 1592.80 | 20 | 14.36 | 2488 | 715 | 2.65 / 385.21 | 2 | 2 |
5 | 13 | 1021.20 | 20 | 14.53 | 1733 | 504 | 3.15 / 385.71 | 2 | 2 |
6 | 13 | 310.56 | 20 | 14.86 | 781 | 232 | 3.39 / 385.94 | 2 | 2 |
7 | 13 | 34.48 | 20 | 15.00 | 384 | 115 | 3.50 / 386.06 | 2 | 2 |
8 | 8 | 0.00 | 175 | 14.98 | 326 | 855 | 4.35 / 386.91 | 2 | 5 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.52 | 22 | 14.96 | 478 | 157 | 0.16 / 378.35 | 2 | 2 |
2 | 7 | 2001.52 | 42 | 14.22 | 2981 | 1780 | 1.94 / 380.13 | 2 | 2 |
3 | 13 | 1602.16 | 20 | 14.35 | 2503 | 718 | 2.66 / 380.85 | 2 | 2 |
4 | 13 | 1037.84 | 20 | 14.53 | 1756 | 510 | 3.17 / 381.36 | 2 | 2 |
5 | 13 | 319.96 | 20 | 14.86 | 791 | 235 | 3.40 / 381.60 | 2 | 2 |
6 | 13 | 35.80 | 20 | 15.01 | 382 | 115 | 3.52 / 381.71 | 2 | 2 |
7 | 8 | 0.08 | 175 | 14.98 | 323 | 847 | 4.36 / 382.56 | 2 | 3 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.64 | 22 | 14.94 | 482 | 158 | 0.16 / 374.16 | 2 | 2 |
2 | 7 | 2002.76 | 42 | 14.22 | 2979 | 1779 | 1.94 / 375.94 | 2 | 2 |
3 | 13 | 1584.88 | 20 | 14.36 | 2491 | 715 | 2.65 / 376.65 | 2 | 2 |
4 | 13 | 900.08 | 20 | 14.59 | 1577 | 460 | 3.11 / 377.11 | 2 | 2 |
5 | 13 | 326.96 | 20 | 14.85 | 801 | 238 | 3.35 / 377.35 | 2 | 2 |
6 | 8 | 0.08 | 175 | 14.99 | 323 | 847 | 4.20 / 378.20 | 2 | 3 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.16 | 22 | 14.94 | 482 | 158 | 0.16 / 369.74 | 2 | 2 |
2 | 7 | 2003.28 | 42 | 14.21 | 2997 | 1789 | 1.95 / 371.52 | 2 | 2 |
3 | 13 | 1597.24 | 20 | 14.36 | 2491 | 715 | 2.66 / 372.24 | 2 | 2 |
4 | 13 | 1024.20 | 20 | 14.53 | 1736 | 504 | 3.17 / 372.74 | 2 | 2 |
5 | 13 | 446.40 | 20 | 14.79 | 968 | 286 | 3.45 / 373.03 | 2 | 2 |
6 | 13 | 29.40 | 20 | 15.01 | 376 | 113 | 3.57 / 373.14 | 2 | 2 |
7 | 8 | 0.20 | 175 | 14.98 | 326 | 855 | 4.42 / 374.00 | 2 | 7 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.92 | 22 | 14.94 | 478 | 157 | 0.16 / 365.36 | 2 | 2 |
2 | 7 | 2004.00 | 42 | 14.22 | 2991 | 1786 | 1.94 / 367.14 | 2 | 2 |
3 | 13 | 1598.28 | 20 | 14.36 | 2494 | 716 | 2.66 / 367.86 | 2 | 2 |
4 | 13 | 1033.68 | 20 | 14.53 | 1751 | 509 | 3.17 / 368.37 | 2 | 2 |
5 | 13 | 312.60 | 20 | 14.86 | 786 | 234 | 3.40 / 368.60 | 2 | 2 |
6 | 13 | 35.92 | 20 | 15.00 | 389 | 117 | 3.52 / 368.72 | 2 | 2 |
7 | 8 | 0.08 | 175 | 14.98 | 327 | 857 | 4.38 / 369.58 | 2 | 4 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.80 | 21 | 14.94 | 477 | 150 | 0.15 / 360.93 | 2 | 2 |
2 | 3 | 1023.24 | 1 | 15.06 | 1873 | 28 | 0.18 / 360.96 | 2 | 2 |
3 | 7 | 2003.04 | 42 | 14.22 | 2999 | 1791 | 1.97 / 362.75 | 2 | 2 |
4 | 13 | 1730.24 | 20 | 14.31 | 2690 | 770 | 2.74 / 363.52 | 2 | 2 |
5 | 13 | 1002.72 | 20 | 14.55 | 1708 | 497 | 3.24 / 364.02 | 2 | 2 |
6 | 13 | 293.40 | 20 | 14.87 | 758 | 225 | 3.46 / 364.25 | 2 | 2 |
7 | 13 | 15.56 | 20 | 15.02 | 354 | 106 | 3.57 / 364.35 | 2 | 2 |
8 | 8 | 0.08 | 175 | 14.98 | 324 | 849 | 4.42 / 365.20 | 2 | 2 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.96 | 22 | 14.94 | 490 | 161 | 0.16 / 356.55 | 2 | 2 |
2 | 7 | 2013.24 | 42 | 14.21 | 3014 | 1799 | 1.96 / 358.35 | 2 | 2 |
3 | 13 | 1606.68 | 20 | 14.35 | 2509 | 720 | 2.68 / 359.07 | 2 | 2 |
4 | 13 | 1033.36 | 20 | 14.53 | 1760 | 511 | 3.19 / 359.58 | 2 | 2 |
5 | 13 | 326.48 | 20 | 14.86 | 806 | 240 | 3.43 / 359.82 | 2 | 2 |
6 | 13 | 37.40 | 20 | 15.00 | 389 | 117 | 3.55 / 359.94 | 2 | 2 |
7 | 8 | 0.08 | 175 | 14.98 | 324 | 849 | 4.40 / 360.78 | 2 | 5 |
Average= | 4.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.00 | 21 | 14.94 | 485 | 152 | 0.15 / 352.22 | 2 | 2 |
2 | 3 | 1039.52 | 1 | 15.00 | 1891 | 28 | 0.18 / 352.25 | 2 | 2 |
3 | 7 | 2004.56 | 42 | 14.22 | 2989 | 1785 | 1.97 / 354.03 | 2 | 2 |
4 | 13 | 1595.28 | 20 | 14.36 | 2498 | 717 | 2.68 / 354.75 | 2 | 2 |
5 | 13 | 1022.00 | 20 | 14.54 | 1745 | 507 | 3.19 / 355.26 | 2 | 2 |
6 | 13 | 438.32 | 20 | 14.80 | 958 | 284 | 3.47 / 355.54 | 2 | 2 |
7 | 8 | 0.24 | 175 | 14.99 | 323 | 847 | 4.32 / 356.39 | 2 | 2 |
Average= | 4.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.56 | 22 | 14.93 | 482 | 158 | 0.16 / 347.89 | 2 | 2 |
2 | 3 | 952.08 | -1 | 15.42 | 0 | 0 | 0.00 / 347.89 | 2 | 2 |
3 | 7 | 2005.96 | 42 | 14.22 | 2985 | 1783 | 1.94 / 349.67 | 2 | 2 |
4 | 13 | 1726.20 | 20 | 14.32 | 2660 | 762 | 2.70 / 350.43 | 2 | 2 |
5 | 13 | 1004.80 | 20 | 14.55 | 1706 | 496 | 3.20 / 350.93 | 2 | 2 |
6 | 13 | 424.20 | 20 | 14.80 | 942 | 279 | 3.48 / 351.21 | 2 | 2 |
7 | 8 | 0.12 | 175 | 14.99 | 328 | 860 | 4.34 / 352.07 | 2 | 3 |
Average= | 4.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.12 | 21 | 14.93 | 491 | 154 | 0.15 / 343.29 | 2 | 2 |
2 | 3 | 1019.56 | 1 | 15.09 | 1875 | 28 | 0.18 / 343.32 | 2 | 2 |
3 | 7 | 2007.08 | 43 | 14.21 | 3005 | 1836 | 2.02 / 345.16 | 2 | 2 |
4 | 13 | 1607.08 | 20 | 14.35 | 2519 | 723 | 2.74 / 345.88 | 2 | 2 |
5 | 13 | 1024.56 | 20 | 14.54 | 1732 | 504 | 3.25 / 346.38 | 2 | 2 |
6 | 13 | 308.96 | 20 | 14.86 | 778 | 231 | 3.48 / 346.61 | 2 | 2 |
7 | 13 | 16.76 | 20 | 15.02 | 362 | 109 | 3.58 / 346.72 | 2 | 2 |
8 | 8 | 0.00 | 175 | 14.98 | 327 | 857 | 4.44 / 347.58 | 2 | 3 |
9 | 14 | 0.00 | 30 | 14.96 | 329 | 148 | 4.59 / 347.73 | 2 | 4 |
Average= | 4.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.12 | 21 | 14.94 | 484 | 152 | 0.15 / 338.89 | 2 | 2 |
2 | 7 | 2006.04 | 42 | 14.21 | 3005 | 1793 | 1.95 / 340.68 | 2 | 2 |
3 | 13 | 1587.12 | 20 | 14.36 | 2487 | 714 | 2.66 / 341.40 | 2 | 2 |
4 | 13 | 900.24 | 20 | 14.59 | 1575 | 460 | 3.12 / 341.86 | 2 | 2 |
5 | 13 | 469.72 | 20 | 14.77 | 1003 | 296 | 3.42 / 342.15 | 2 | 2 |
6 | 13 | 33.00 | 20 | 15.00 | 387 | 116 | 3.53 / 342.27 | 2 | 2 |
7 | 8 | 0.20 | 175 | 14.97 | 332 | 870 | 4.40 / 343.14 | 2 | 3 |
Average= | 4.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.44 | 22 | 14.94 | 487 | 160 | 0.16 / 334.63 | 2 | 2 |
2 | 7 | 2001.52 | 42 | 14.22 | 2999 | 1791 | 1.95 / 336.42 | 2 | 2 |
3 | 13 | 1593.08 | 20 | 14.36 | 2491 | 715 | 2.67 / 337.13 | 2 | 2 |
4 | 13 | 1029.84 | 20 | 14.54 | 1745 | 507 | 3.17 / 337.64 | 2 | 2 |
5 | 13 | 303.80 | 20 | 14.87 | 775 | 230 | 3.40 / 337.87 | 2 | 2 |
6 | 8 | 0.08 | 175 | 14.98 | 330 | 865 | 4.27 / 338.74 | 2 | 2 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.52 | 21 | 14.93 | 495 | 155 | 0.16 / 330.36 | 2 | 2 |
2 | 7 | 2006.00 | 42 | 14.22 | 3010 | 1798 | 1.95 / 332.16 | 2 | 2 |
3 | 13 | 1477.48 | 20 | 14.40 | 2352 | 677 | 2.63 / 332.84 | 2 | 2 |
4 | 13 | 1059.20 | 20 | 14.52 | 1794 | 521 | 3.15 / 333.36 | 2 | 2 |
5 | 13 | 332.04 | 20 | 14.85 | 816 | 242 | 3.39 / 333.60 | 2 | 2 |
6 | 8 | 0.20 | 175 | 14.98 | 331 | 868 | 4.26 / 334.47 | 2 | 13 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.12 | 21 | 14.93 | 492 | 154 | 0.15 / 326.06 | 2 | 2 |
2 | 7 | 2003.08 | 42 | 14.23 | 2983 | 1783 | 1.94 / 327.84 | 2 | 2 |
3 | 13 | 1597.44 | 20 | 14.36 | 2497 | 717 | 2.65 / 328.56 | 2 | 2 |
4 | 13 | 1027.40 | 20 | 14.54 | 1736 | 505 | 3.16 / 329.06 | 2 | 2 |
5 | 13 | 446.84 | 20 | 14.79 | 971 | 287 | 3.45 / 329.35 | 2 | 2 |
6 | 8 | 0.04 | 175 | 14.98 | 326 | 855 | 4.30 / 330.21 | 2 | 3 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.20 | 21 | 14.93 | 494 | 155 | 0.15 / 321.73 | 2 | 2 |
2 | 7 | 2004.60 | 42 | 14.23 | 2984 | 1783 | 1.94 / 323.51 | 2 | 2 |
3 | 13 | 1735.52 | 20 | 14.32 | 2664 | 763 | 2.70 / 324.27 | 2 | 2 |
4 | 13 | 1004.40 | 20 | 14.55 | 1706 | 496 | 3.20 / 324.77 | 2 | 2 |
5 | 13 | 421.76 | 20 | 14.81 | 932 | 276 | 3.47 / 325.05 | 2 | 2 |
6 | 8 | 0.24 | 175 | 14.99 | 327 | 858 | 4.33 / 325.90 | 2 | 5 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.56 | 21 | 14.93 | 500 | 157 | 0.16 / 317.43 | 2 | 2 |
2 | 7 | 2003.00 | 42 | 14.23 | 2981 | 1782 | 1.94 / 319.21 | 2 | 2 |
3 | 13 | 1587.16 | 20 | 14.37 | 2493 | 716 | 2.65 / 319.93 | 2 | 2 |
4 | 13 | 1011.80 | 20 | 14.55 | 1723 | 501 | 3.16 / 320.43 | 2 | 2 |
5 | 13 | 430.04 | 20 | 14.81 | 944 | 280 | 3.44 / 320.71 | 2 | 2 |
6 | 8 | -0.08 | 175 | 14.99 | 330 | 866 | 4.30 / 321.57 | 2 | 2 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.36 | 21 | 14.93 | 495 | 155 | 0.16 / 313.12 | 2 | 2 |
2 | 7 | 2001.88 | 42 | 14.23 | 2985 | 1784 | 1.94 / 314.91 | 2 | 2 |
3 | 13 | 1583.60 | 20 | 14.38 | 2487 | 715 | 2.65 / 315.62 | 2 | 2 |
4 | 13 | 1016.72 | 20 | 14.55 | 1729 | 503 | 3.16 / 316.13 | 2 | 2 |
5 | 13 | 432.52 | 20 | 14.81 | 949 | 281 | 3.44 / 316.41 | 2 | 2 |
6 | 8 | 0.16 | 175 | 14.99 | 329 | 863 | 4.30 / 317.27 | 2 | 3 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.68 | 22 | 14.93 | 503 | 165 | 0.17 / 308.83 | 2 | 2 |
2 | 7 | 2003.24 | 43 | 14.23 | 2994 | 1832 | 2.00 / 310.66 | 2 | 2 |
3 | 13 | 1593.24 | 20 | 14.38 | 2484 | 714 | 2.71 / 311.37 | 2 | 2 |
4 | 13 | 1016.08 | 20 | 14.55 | 1723 | 501 | 3.21 / 311.87 | 2 | 2 |
5 | 13 | 300.08 | 20 | 14.88 | 761 | 226 | 3.44 / 312.10 | 2 | 2 |
6 | 8 | 0.36 | 175 | 14.99 | 331 | 868 | 4.31 / 312.97 | 2 | 2 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.28 | 21 | 14.94 | 499 | 157 | 0.16 / 304.55 | 2 | 2 |
2 | 7 | 2003.92 | 42 | 14.23 | 2996 | 1791 | 1.95 / 306.34 | 2 | 2 |
3 | 13 | 1594.36 | 20 | 14.38 | 2502 | 720 | 2.67 / 307.06 | 2 | 2 |
4 | 13 | 1019.32 | 20 | 14.55 | 1737 | 505 | 3.17 / 307.57 | 2 | 2 |
5 | 13 | 305.68 | 20 | 14.88 | 774 | 230 | 3.40 / 307.80 | 2 | 2 |
6 | 8 | -0.04 | 175 | 14.99 | 330 | 866 | 4.27 / 308.66 | 2 | 3 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.88 | 21 | 14.94 | 492 | 154 | 0.15 / 300.25 | 2 | 2 |
2 | 7 | 2005.28 | 42 | 14.24 | 2988 | 1787 | 1.94 / 302.04 | 2 | 2 |
3 | 13 | 1726.44 | 20 | 14.34 | 2658 | 762 | 2.70 / 302.80 | 2 | 2 |
4 | 13 | 994.92 | 20 | 14.57 | 1705 | 497 | 3.20 / 303.30 | 2 | 2 |
5 | 13 | 285.12 | 20 | 14.89 | 752 | 224 | 3.42 / 303.52 | 2 | 2 |
6 | 8 | -0.12 | 175 | 15.00 | 332 | 871 | 4.30 / 304.39 | 2 | 2 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.44 | 21 | 14.95 | 486 | 153 | 0.15 / 295.92 | 2 | 2 |
2 | 7 | 2005.64 | 42 | 14.24 | 3004 | 1797 | 1.95 / 297.72 | 2 | 2 |
3 | 13 | 1594.12 | 20 | 14.39 | 2478 | 713 | 2.66 / 298.43 | 2 | 2 |
4 | 13 | 1020.00 | 20 | 14.56 | 1735 | 505 | 3.17 / 298.94 | 2 | 2 |
5 | 13 | 435.48 | 20 | 14.82 | 958 | 284 | 3.45 / 299.22 | 2 | 2 |
6 | 8 | 0.60 | 175 | 15.00 | 334 | 877 | 4.33 / 300.10 | 2 | 5 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.76 | 21 | 14.96 | 486 | 153 | 0.15 / 291.40 | 2 | 2 |
2 | 7 | 2004.08 | 42 | 14.24 | 2977 | 1780 | 1.93 / 293.18 | 2 | 2 |
3 | 13 | 1590.12 | 20 | 14.39 | 2490 | 717 | 2.65 / 293.90 | 2 | 2 |
4 | 13 | 1009.56 | 20 | 14.57 | 1720 | 501 | 3.15 / 294.40 | 2 | 2 |
5 | 13 | 289.04 | 20 | 14.90 | 748 | 223 | 3.37 / 294.63 | 2 | 2 |
6 | 13 | 64.28 | 20 | 15.01 | 427 | 128 | 3.50 / 294.75 | 2 | 2 |
7 | 8 | -0.08 | 175 | 14.99 | 330 | 866 | 4.37 / 295.62 | 2 | 5 |
8 | 14 | -0.08 | 30 | 14.97 | 334 | 150 | 4.52 / 295.77 | 2 | 2 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.44 | 21 | 14.96 | 482 | 151 | 0.15 / 287.11 | 2 | 2 |
2 | 7 | 2005.88 | 42 | 14.25 | 2981 | 1784 | 1.94 / 288.90 | 2 | 2 |
3 | 13 | 1732.68 | 20 | 14.35 | 2665 | 765 | 2.70 / 289.66 | 2 | 2 |
4 | 13 | 1018.88 | 20 | 14.57 | 1729 | 504 | 3.20 / 290.17 | 2 | 2 |
5 | 13 | 312.28 | 20 | 14.90 | 772 | 230 | 3.43 / 290.40 | 2 | 2 |
6 | 8 | 0.12 | 175 | 15.01 | 326 | 856 | 4.29 / 291.25 | 2 | 2 |
Average= | 4.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.16 | 21 | 14.96 | 498 | 156 | 0.16 / 282.83 | 2 | 2 |
2 | 3 | 1027.20 | 1 | 15.07 | 1884 | 28 | 0.18 / 282.86 | 2 | 2 |
3 | 7 | 2005.08 | 42 | 14.25 | 2991 | 1790 | 1.97 / 284.65 | 2 | 2 |
4 | 13 | 1593.44 | 20 | 14.40 | 2491 | 717 | 2.69 / 285.36 | 2 | 2 |
5 | 13 | 1027.76 | 20 | 14.57 | 1739 | 507 | 3.20 / 285.87 | 2 | 2 |
6 | 13 | 318.68 | 20 | 14.89 | 788 | 235 | 3.43 / 286.10 | 2 | 2 |
7 | 8 | 0.16 | 175 | 15.01 | 326 | 856 | 4.29 / 286.96 | 2 | 4 |
Average= | 4.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.84 | 21 | 14.97 | 481 | 151 | 0.15 / 278.55 | 2 | 2 |
2 | 7 | 2003.20 | 43 | 14.25 | 2985 | 1829 | 1.98 / 280.37 | 2 | 2 |
3 | 13 | 1585.68 | 20 | 14.40 | 2497 | 719 | 2.70 / 281.09 | 2 | 2 |
4 | 13 | 998.00 | 20 | 14.59 | 1708 | 498 | 3.20 / 281.59 | 2 | 2 |
5 | 13 | 267.68 | 20 | 14.93 | 715 | 213 | 3.41 / 281.81 | 2 | 2 |
6 | 8 | 0.12 | 175 | 15.02 | 329 | 865 | 4.28 / 282.67 | 2 | 2 |
Average= | 4.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.28 | 21 | 14.98 | 487 | 153 | 0.15 / 274.17 | 2 | 2 |
2 | 7 | 2002.12 | 42 | 14.25 | 2989 | 1789 | 1.94 / 275.96 | 2 | 2 |
3 | 13 | 1605.32 | 20 | 14.40 | 2515 | 724 | 2.67 / 276.68 | 2 | 2 |
4 | 13 | 1025.44 | 20 | 14.58 | 1744 | 509 | 3.17 / 277.19 | 2 | 2 |
5 | 13 | 316.24 | 20 | 14.90 | 786 | 234 | 3.41 / 277.43 | 2 | 2 |
6 | 13 | 19.08 | 20 | 15.06 | 356 | 107 | 3.52 / 277.53 | 2 | 2 |
7 | 8 | 0.00 | 175 | 15.01 | 328 | 862 | 4.38 / 278.39 | 2 | 6 |
Average= | 4.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.20 | 21 | 14.99 | 483 | 152 | 0.15 / 269.90 | 2 | 2 |
2 | 7 | 2002.00 | 42 | 14.26 | 2994 | 1793 | 1.95 / 271.69 | 2 | 2 |
3 | 13 | 1590.40 | 20 | 14.41 | 2509 | 723 | 2.67 / 272.41 | 2 | 2 |
4 | 13 | 1018.56 | 20 | 14.59 | 1735 | 506 | 3.17 / 272.92 | 2 | 2 |
5 | 13 | 310.16 | 20 | 14.91 | 782 | 233 | 3.41 / 273.15 | 2 | 2 |
6 | 8 | 0.08 | 175 | 15.03 | 328 | 863 | 4.27 / 274.02 | 2 | 3 |
Average= | 4.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.52 | 22 | 14.99 | 484 | 160 | 0.16 / 265.59 | 2 | 2 |
2 | 3 | 945.08 | -1 | 15.45 | 0 | 0 | 0.00 / 265.59 | 2 | 2 |
3 | 7 | 2002.12 | 42 | 14.26 | 2980 | 1785 | 1.94 / 267.38 | 2 | 2 |
4 | 13 | 1582.72 | 20 | 14.42 | 2488 | 718 | 2.66 / 268.10 | 2 | 2 |
5 | 13 | 1015.44 | 20 | 14.59 | 1726 | 504 | 3.17 / 268.60 | 2 | 2 |
6 | 13 | 432.56 | 20 | 14.85 | 952 | 283 | 3.45 / 268.88 | 2 | 2 |
7 | 8 | 0.04 | 175 | 15.03 | 328 | 863 | 4.31 / 269.75 | 2 | 3 |
Average= | 4.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.20 | 21 | 14.99 | 479 | 151 | 0.15 / 261.20 | 2 | 2 |
2 | 3 | 1061.80 | 2 | 14.96 | 1905 | 57 | 0.21 / 261.25 | 2 | 2 |
3 | 7 | 2002.36 | 42 | 14.25 | 2985 | 1787 | 1.99 / 263.04 | 2 | 2 |
4 | 13 | 1721.60 | 20 | 14.37 | 2670 | 767 | 2.76 / 263.81 | 2 | 2 |
5 | 13 | 989.64 | 20 | 14.60 | 1697 | 496 | 3.26 / 264.30 | 2 | 2 |
6 | 13 | 407.36 | 20 | 14.87 | 914 | 272 | 3.53 / 264.57 | 2 | 2 |
7 | 8 | 0.56 | 175 | 15.03 | 327 | 860 | 4.39 / 265.44 | 2 | 3 |
Average= | 4.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.96 | 21 | 15.00 | 479 | 151 | 0.15 / 256.86 | 2 | 2 |
2 | 7 | 2004.84 | 42 | 14.25 | 3007 | 1800 | 1.95 / 258.66 | 2 | 2 |
3 | 13 | 1456.56 | 20 | 14.46 | 2318 | 670 | 2.62 / 259.33 | 2 | 2 |
4 | 13 | 902.04 | 20 | 14.65 | 1584 | 464 | 3.09 / 259.80 | 2 | 2 |
5 | 13 | 333.36 | 20 | 14.91 | 811 | 242 | 3.33 / 260.04 | 2 | 2 |
6 | 8 | -0.20 | 175 | 15.04 | 326 | 858 | 4.18 / 260.90 | 2 | 3 |
7 | 14 | -0.20 | 30 | 15.02 | 331 | 149 | 4.33 / 261.05 | 2 | 2 |
Average= | 4.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.60 | 21 | 15.00 | 485 | 153 | 0.15 / 252.57 | 2 | 2 |
2 | 7 | 2004.28 | 42 | 14.27 | 2979 | 1785 | 1.94 / 254.35 | 2 | 2 |
3 | 13 | 1592.68 | 20 | 14.43 | 2492 | 719 | 2.66 / 255.07 | 2 | 2 |
4 | 13 | 1022.04 | 20 | 14.61 | 1733 | 506 | 3.16 / 255.58 | 2 | 2 |
5 | 13 | 431.84 | 20 | 14.87 | 938 | 279 | 3.44 / 255.86 | 2 | 2 |
6 | 8 | 0.28 | 175 | 15.04 | 324 | 853 | 4.30 / 256.71 | 2 | 3 |
Average= | 4.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.44 | 21 | 15.01 | 478 | 151 | 0.15 / 248.33 | 2 | 2 |
2 | 7 | 2003.52 | 42 | 14.26 | 2998 | 1796 | 1.95 / 250.12 | 2 | 2 |
3 | 13 | 1584.20 | 20 | 14.43 | 2483 | 717 | 2.66 / 250.84 | 2 | 2 |
4 | 13 | 1005.44 | 20 | 14.62 | 1716 | 502 | 3.16 / 251.34 | 2 | 2 |
5 | 13 | 281.12 | 20 | 14.95 | 735 | 220 | 3.38 / 251.56 | 2 | 2 |
6 | 8 | -0.04 | 175 | 15.05 | 325 | 856 | 4.24 / 252.42 | 2 | 2 |
Average= | 4.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.96 | 21 | 15.01 | 482 | 152 | 0.15 / 244.08 | 2 | 2 |
2 | 7 | 2002.20 | 42 | 14.27 | 2989 | 1791 | 1.94 / 245.88 | 2 | 2 |
3 | 13 | 1574.76 | 20 | 14.44 | 2478 | 716 | 2.66 / 246.59 | 2 | 2 |
4 | 13 | 1007.24 | 20 | 14.62 | 1720 | 503 | 3.16 / 247.09 | 2 | 2 |
5 | 13 | 291.00 | 20 | 14.94 | 754 | 225 | 3.39 / 247.32 | 2 | 2 |
6 | 8 | 0.28 | 175 | 15.05 | 325 | 856 | 4.24 / 248.18 | 2 | 9 |
Average= | 4.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.04 | 20 | 15.01 | 479 | 144 | 0.14 / 239.54 | 2 | 2 |
2 | 3 | 1043.32 | 1 | 15.02 | 1895 | 28 | 0.17 / 239.57 | 2 | 2 |
3 | 7 | 2004.60 | 42 | 14.27 | 2991 | 1793 | 1.96 / 241.36 | 2 | 2 |
4 | 13 | 1585.16 | 20 | 14.43 | 2486 | 717 | 2.68 / 242.08 | 2 | 2 |
5 | 13 | 877.96 | 20 | 14.68 | 1551 | 455 | 3.14 / 242.53 | 2 | 2 |
6 | 13 | 442.20 | 20 | 14.87 | 957 | 285 | 3.42 / 242.82 | 2 | 2 |
7 | 13 | 28.48 | 20 | 15.08 | 375 | 113 | 3.54 / 242.93 | 2 | 2 |
8 | 8 | 0.00 | 175 | 15.05 | 324 | 853 | 4.39 / 243.79 | 2 | 2 |
9 | 14 | 0.00 | 30 | 15.03 | 327 | 147 | 4.54 / 243.93 | 2 | 4 |
Average= | 4.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.16 | 21 | 15.01 | 476 | 150 | 0.15 / 235.22 | 2 | 2 |
2 | 3 | 960.04 | -1 | 15.46 | 0 | 0 | 0.00 / 235.22 | 2 | 2 |
3 | 7 | 2005.76 | 43 | 14.27 | 2997 | 1839 | 1.99 / 237.06 | 2 | 2 |
4 | 13 | 1582.44 | 20 | 14.44 | 2490 | 719 | 2.71 / 237.78 | 2 | 2 |
5 | 13 | 872.72 | 20 | 14.68 | 1547 | 454 | 3.16 / 238.23 | 2 | 2 |
6 | 13 | 176.32 | 20 | 15.01 | 591 | 177 | 3.34 / 238.41 | 2 | 2 |
7 | 13 | 38.40 | 20 | 15.08 | 391 | 118 | 3.46 / 238.53 | 2 | 2 |
8 | 8 | 0.00 | 175 | 15.05 | 329 | 867 | 4.32 / 239.40 | 2 | 10 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.28 | 21 | 15.02 | 481 | 152 | 0.15 / 230.85 | 2 | 2 |
2 | 3 | 1031.56 | 1 | 15.07 | 1872 | 28 | 0.18 / 230.88 | 2 | 2 |
3 | 7 | 2001.64 | 42 | 14.28 | 2991 | 1794 | 1.97 / 232.67 | 2 | 2 |
4 | 13 | 1597.12 | 20 | 14.44 | 2497 | 721 | 2.69 / 233.39 | 2 | 2 |
5 | 13 | 892.00 | 20 | 14.68 | 1567 | 460 | 3.16 / 233.85 | 2 | 2 |
6 | 13 | 334.96 | 20 | 14.93 | 812 | 242 | 3.40 / 234.09 | 2 | 2 |
7 | 13 | 39.20 | 20 | 15.08 | 391 | 118 | 3.52 / 234.21 | 2 | 2 |
8 | 8 | -0.04 | 175 | 15.05 | 327 | 861 | 4.38 / 235.07 | 2 | 5 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.04 | 21 | 15.03 | 485 | 153 | 0.15 / 226.53 | 2 | 2 |
2 | 7 | 2003.96 | 42 | 14.28 | 2988 | 1792 | 1.95 / 228.32 | 2 | 2 |
3 | 13 | 1591.28 | 20 | 14.44 | 2490 | 719 | 2.66 / 229.04 | 2 | 2 |
4 | 13 | 1023.16 | 20 | 14.63 | 1735 | 508 | 3.17 / 229.55 | 2 | 2 |
5 | 13 | 434.88 | 20 | 14.88 | 954 | 284 | 3.46 / 229.83 | 2 | 2 |
6 | 8 | 0.32 | 175 | 15.06 | 328 | 864 | 4.32 / 230.70 | 2 | 4 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.56 | 21 | 15.02 | 483 | 152 | 0.15 / 222.31 | 2 | 2 |
2 | 7 | 2002.08 | 42 | 14.28 | 3012 | 1806 | 1.96 / 224.12 | 2 | 2 |
3 | 13 | 1602.68 | 20 | 14.44 | 2506 | 724 | 2.68 / 224.84 | 2 | 2 |
4 | 13 | 905.28 | 20 | 14.68 | 1597 | 469 | 3.15 / 225.31 | 2 | 2 |
5 | 13 | 216.84 | 20 | 15.00 | 649 | 195 | 3.35 / 225.51 | 2 | 2 |
6 | 8 | 0.16 | 175 | 15.07 | 330 | 870 | 4.22 / 226.38 | 2 | 2 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.00 | 21 | 15.03 | 485 | 153 | 0.15 / 217.93 | 2 | 2 |
2 | 7 | 2003.24 | 42 | 14.29 | 2993 | 1796 | 1.95 / 219.73 | 2 | 2 |
3 | 13 | 1590.28 | 20 | 14.45 | 2486 | 718 | 2.67 / 220.45 | 2 | 2 |
4 | 13 | 1011.80 | 20 | 14.64 | 1725 | 505 | 3.17 / 220.95 | 2 | 2 |
5 | 13 | 301.60 | 20 | 14.96 | 768 | 230 | 3.40 / 221.18 | 2 | 2 |
6 | 13 | 17.44 | 20 | 15.10 | 360 | 109 | 3.51 / 221.29 | 2 | 2 |
7 | 8 | -0.20 | 175 | 15.06 | 329 | 867 | 4.38 / 222.16 | 2 | 3 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.16 | 21 | 15.03 | 475 | 150 | 0.15 / 213.62 | 2 | 2 |
2 | 3 | 1018.36 | 1 | 15.13 | 1865 | 28 | 0.18 / 213.65 | 2 | 2 |
3 | 7 | 2003.64 | 42 | 14.29 | 3015 | 1810 | 1.99 / 215.46 | 2 | 2 |
4 | 13 | 1589.20 | 20 | 14.46 | 2483 | 718 | 2.71 / 216.17 | 2 | 2 |
5 | 13 | 1013.96 | 20 | 14.64 | 1723 | 504 | 3.21 / 216.68 | 2 | 2 |
6 | 13 | 302.76 | 20 | 14.96 | 763 | 228 | 3.44 / 216.91 | 2 | 2 |
7 | 8 | 0.20 | 175 | 15.07 | 331 | 873 | 4.31 / 217.78 | 2 | 3 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.64 | 21 | 15.03 | 480 | 152 | 0.15 / 209.37 | 2 | 2 |
2 | 7 | 2005.52 | 42 | 14.30 | 3001 | 1802 | 1.95 / 211.18 | 2 | 2 |
3 | 13 | 1476.36 | 20 | 14.50 | 2347 | 681 | 2.63 / 211.86 | 2 | 2 |
4 | 13 | 1048.68 | 20 | 14.63 | 1761 | 515 | 3.15 / 212.37 | 2 | 2 |
5 | 13 | 307.04 | 20 | 14.96 | 777 | 232 | 3.38 / 212.60 | 2 | 2 |
6 | 8 | 0.12 | 175 | 15.07 | 328 | 865 | 4.25 / 213.47 | 2 | 2 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.96 | 20 | 15.03 | 497 | 149 | 0.15 / 205.10 | 2 | 2 |
2 | 7 | 2004.48 | 42 | 14.30 | 3005 | 1805 | 1.95 / 206.90 | 2 | 2 |
3 | 13 | 1598.36 | 20 | 14.46 | 2503 | 724 | 2.68 / 207.63 | 2 | 2 |
4 | 13 | 1020.92 | 20 | 14.64 | 1746 | 511 | 3.19 / 208.14 | 2 | 2 |
5 | 13 | 298.92 | 20 | 14.97 | 755 | 226 | 3.42 / 208.36 | 2 | 2 |
6 | 8 | 0.04 | 175 | 15.08 | 325 | 858 | 4.27 / 209.22 | 2 | 3 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.64 | 21 | 15.03 | 492 | 155 | 0.16 / 200.80 | 2 | 2 |
2 | 7 | 2002.68 | 42 | 14.31 | 2986 | 1795 | 1.95 / 202.59 | 2 | 2 |
3 | 13 | 1469.00 | 20 | 14.50 | 2332 | 676 | 2.63 / 203.27 | 2 | 2 |
4 | 13 | 1048.84 | 20 | 14.63 | 1767 | 517 | 3.14 / 203.79 | 2 | 2 |
5 | 13 | 466.48 | 20 | 14.88 | 994 | 296 | 3.44 / 204.08 | 2 | 2 |
6 | 8 | 0.24 | 175 | 15.07 | 329 | 868 | 4.31 / 204.95 | 2 | 2 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.04 | 21 | 15.04 | 482 | 152 | 0.15 / 196.56 | 2 | 2 |
2 | 7 | 2004.08 | 42 | 14.30 | 3000 | 1802 | 1.95 / 198.36 | 2 | 2 |
3 | 13 | 1590.76 | 20 | 14.46 | 2495 | 722 | 2.68 / 199.08 | 2 | 2 |
4 | 13 | 885.40 | 20 | 14.71 | 1559 | 459 | 3.13 / 199.54 | 2 | 2 |
5 | 13 | 318.04 | 20 | 14.96 | 794 | 238 | 3.37 / 199.78 | 2 | 2 |
6 | 8 | 0.08 | 175 | 15.08 | 327 | 863 | 4.23 / 200.64 | 2 | 2 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.04 | 21 | 15.04 | 480 | 152 | 0.15 / 192.29 | 2 | 2 |
2 | 7 | 2003.92 | 43 | 14.30 | 3010 | 1851 | 2.00 / 194.14 | 2 | 2 |
3 | 13 | 1724.80 | 20 | 14.42 | 2665 | 769 | 2.77 / 194.91 | 2 | 2 |
4 | 13 | 862.84 | 20 | 14.72 | 1532 | 451 | 3.22 / 195.36 | 2 | 2 |
5 | 13 | 169.88 | 20 | 15.04 | 583 | 175 | 3.40 / 195.54 | 2 | 2 |
6 | 8 | 0.00 | 175 | 15.08 | 329 | 868 | 4.27 / 196.41 | 2 | 3 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.00 | 20 | 15.03 | 503 | 151 | 0.15 / 188.12 | 2 | 2 |
2 | 7 | 2005.08 | 42 | 14.32 | 2981 | 1793 | 1.94 / 189.91 | 2 | 2 |
3 | 13 | 1591.36 | 20 | 14.48 | 2488 | 721 | 2.66 / 190.63 | 2 | 2 |
4 | 13 | 896.28 | 20 | 14.71 | 1568 | 461 | 3.13 / 191.09 | 2 | 2 |
5 | 13 | 202.68 | 20 | 15.03 | 623 | 187 | 3.31 / 191.28 | 2 | 2 |
6 | 8 | 0.12 | 175 | 15.09 | 326 | 861 | 4.17 / 192.14 | 2 | 3 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.16 | 21 | 15.04 | 488 | 154 | 0.15 / 183.76 | 2 | 2 |
2 | 7 | 2004.96 | 42 | 14.32 | 2982 | 1793 | 1.95 / 185.56 | 2 | 2 |
3 | 13 | 1597.92 | 20 | 14.47 | 2499 | 723 | 2.67 / 186.28 | 2 | 2 |
4 | 13 | 1012.52 | 20 | 14.67 | 1716 | 503 | 3.17 / 186.78 | 2 | 2 |
5 | 13 | 286.28 | 20 | 14.99 | 735 | 220 | 3.39 / 187.00 | 2 | 2 |
6 | 13 | 28.52 | 20 | 15.11 | 374 | 113 | 3.51 / 187.12 | 2 | 2 |
7 | 8 | 0.12 | 175 | 15.08 | 322 | 850 | 4.36 / 187.97 | 2 | 4 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.04 | 21 | 15.04 | 493 | 156 | 0.16 / 179.55 | 2 | 2 |
2 | 7 | 2005.64 | 42 | 14.32 | 2973 | 1788 | 1.94 / 181.34 | 2 | 2 |
3 | 13 | 1601.36 | 20 | 14.47 | 2507 | 726 | 2.67 / 182.07 | 2 | 2 |
4 | 13 | 1028.28 | 20 | 14.66 | 1729 | 507 | 3.18 / 182.57 | 2 | 2 |
5 | 13 | 183.20 | 20 | 15.05 | 591 | 178 | 3.35 / 182.75 | 2 | 2 |
6 | 8 | 0.28 | 175 | 15.09 | 325 | 858 | 4.21 / 183.61 | 2 | 4 |
Average= | 4.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.68 | 21 | 15.04 | 485 | 153 | 0.15 / 175.32 | 2 | 2 |
2 | 7 | 2002.72 | 42 | 14.33 | 2975 | 1791 | 1.94 / 177.11 | 2 | 2 |
3 | 13 | 1574.64 | 20 | 14.49 | 2452 | 711 | 2.65 / 177.82 | 2 | 2 |
4 | 13 | 990.28 | 20 | 14.68 | 1684 | 494 | 3.15 / 178.32 | 2 | 2 |
5 | 13 | 274.32 | 20 | 15.00 | 723 | 217 | 3.37 / 178.53 | 2 | 2 |
6 | 8 | 0.28 | 175 | 15.09 | 327 | 864 | 4.23 / 179.40 | 2 | 3 |
Average= | 4.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.92 | 21 | 15.04 | 481 | 152 | 0.15 / 171.00 | 2 | 2 |
2 | 3 | 1024.44 | 1 | 15.13 | 1879 | 28 | 0.18 / 171.03 | 2 | 2 |
3 | 7 | 2005.12 | 43 | 14.32 | 2976 | 1833 | 2.01 / 172.86 | 2 | 2 |
4 | 13 | 1590.84 | 20 | 14.48 | 2489 | 721 | 2.73 / 173.58 | 2 | 2 |
5 | 13 | 1007.16 | 20 | 14.67 | 1709 | 501 | 3.24 / 174.08 | 2 | 2 |
6 | 13 | 276.52 | 20 | 15.00 | 725 | 217 | 3.45 / 174.30 | 2 | 2 |
7 | 8 | 0.00 | 175 | 15.09 | 329 | 869 | 4.32 / 175.17 | 2 | 5 |
Average= | 4.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.88 | 22 | 15.04 | 491 | 162 | 0.16 / 166.70 | 2 | 2 |
2 | 3 | 958.36 | -1 | 15.49 | 0 | 0 | 0.00 / 166.70 | 2 | 2 |
3 | 7 | 2001.80 | 43 | 14.32 | 2977 | 1833 | 2.00 / 168.54 | 2 | 2 |
4 | 13 | 1587.88 | 20 | 14.49 | 2476 | 718 | 2.71 / 169.25 | 2 | 2 |
5 | 13 | 1010.56 | 20 | 14.68 | 1719 | 505 | 3.22 / 169.76 | 2 | 2 |
6 | 13 | 276.56 | 20 | 15.01 | 724 | 217 | 3.44 / 169.98 | 2 | 2 |
7 | 8 | -0.04 | 175 | 15.09 | 330 | 871 | 4.31 / 170.85 | 2 | 2 |
Average= | 4.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.32 | 21 | 15.04 | 493 | 156 | 0.16 / 162.32 | 2 | 2 |
2 | 3 | 1043.96 | 1 | 15.05 | 1879 | 28 | 0.18 / 162.35 | 2 | 2 |
3 | 7 | 2004.00 | 42 | 14.33 | 3007 | 1810 | 1.99 / 164.16 | 2 | 2 |
4 | 13 | 1595.28 | 20 | 14.49 | 2498 | 724 | 2.72 / 164.89 | 2 | 2 |
5 | 13 | 1016.20 | 20 | 14.67 | 1727 | 507 | 3.22 / 165.39 | 2 | 2 |
6 | 13 | 408.84 | 20 | 14.94 | 916 | 274 | 3.50 / 165.67 | 2 | 2 |
7 | 8 | 0.04 | 175 | 15.09 | 331 | 874 | 4.37 / 166.54 | 2 | 2 |
Average= | 4.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.64 | 21 | 15.04 | 505 | 159 | 0.16 / 158.08 | 2 | 2 |
2 | 7 | 2004.84 | 42 | 14.33 | 3000 | 1806 | 1.97 / 159.88 | 2 | 2 |
3 | 13 | 1461.36 | 20 | 14.53 | 2316 | 673 | 2.64 / 160.55 | 2 | 2 |
4 | 13 | 1027.72 | 20 | 14.67 | 1735 | 509 | 3.15 / 161.06 | 2 | 2 |
5 | 13 | 299.96 | 20 | 15.00 | 758 | 227 | 3.37 / 161.29 | 2 | 2 |
6 | 8 | 0.16 | 175 | 15.10 | 332 | 877 | 4.25 / 162.17 | 2 | 4 |
Average= | 4.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.84 | 21 | 15.04 | 491 | 155 | 0.16 / 153.61 | 2 | 2 |
2 | 7 | 2002.32 | 42 | 14.53 | 3032 | 1850 | 2.01 / 155.46 | 2 | 2 |
3 | 13 | 1566.08 | 20 | 14.51 | 2451 | 711 | 2.72 / 156.17 | 2 | 2 |
4 | 13 | 985.72 | 20 | 14.69 | 1685 | 495 | 3.21 / 156.67 | 2 | 2 |
5 | 13 | 406.20 | 20 | 14.95 | 911 | 272 | 3.48 / 156.94 | 2 | 2 |
6 | 13 | 20.20 | 20 | 15.13 | 364 | 110 | 3.59 / 157.05 | 2 | 2 |
7 | 8 | 0.20 | 175 | 15.09 | 329 | 869 | 4.46 / 157.92 | 2 | 3 |
Average= | 4.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.76 | 21 | 15.05 | 482 | 152 | 0.15 / 149.27 | 2 | 2 |
2 | 7 | 2004.60 | 42 | 14.34 | 2986 | 1798 | 1.95 / 151.07 | 2 | 2 |
3 | 13 | 1595.44 | 20 | 14.49 | 2493 | 722 | 2.67 / 151.79 | 2 | 2 |
4 | 13 | 1017.68 | 20 | 14.68 | 1723 | 506 | 3.18 / 152.29 | 2 | 2 |
5 | 13 | 432.16 | 20 | 14.93 | 947 | 283 | 3.46 / 152.58 | 2 | 2 |
6 | 8 | 0.32 | 175 | 15.10 | 332 | 877 | 4.34 / 153.45 | 2 | 2 |
Average= | 4.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.96 | 21 | 15.05 | 486 | 154 | 0.15 / 145.03 | 2 | 2 |
2 | 7 | 2003.08 | 42 | 14.35 | 2976 | 1794 | 1.95 / 146.83 | 2 | 2 |
3 | 13 | 1587.28 | 20 | 14.51 | 2472 | 717 | 2.66 / 147.55 | 2 | 2 |
4 | 13 | 889.72 | 20 | 14.74 | 1559 | 460 | 3.12 / 148.01 | 2 | 2 |
5 | 13 | 323.80 | 20 | 14.99 | 791 | 237 | 3.36 / 148.24 | 2 | 2 |
6 | 8 | 0.00 | 175 | 15.10 | 330 | 872 | 4.23 / 149.11 | 2 | 2 |
Average= | 4.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.92 | 20 | 15.05 | 490 | 147 | 0.15 / 140.71 | 2 | 2 |
2 | 3 | 1026.80 | 1 | 15.12 | 1880 | 28 | 0.18 / 140.74 | 2 | 2 |
3 | 7 | 2003.44 | 43 | 14.35 | 2977 | 1837 | 2.01 / 142.58 | 2 | 2 |
4 | 13 | 1578.64 | 20 | 14.51 | 2460 | 714 | 2.73 / 143.29 | 2 | 2 |
5 | 13 | 1007.16 | 20 | 14.70 | 1708 | 502 | 3.23 / 143.80 | 2 | 2 |
6 | 13 | 272.48 | 20 | 15.03 | 717 | 216 | 3.44 / 144.01 | 2 | 2 |
7 | 8 | 0.16 | 175 | 15.11 | 329 | 870 | 4.31 / 144.88 | 2 | 2 |
Average= | 4.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.40 | 20 | 15.06 | 489 | 147 | 0.15 / 136.50 | 2 | 2 |
2 | 7 | 2002.72 | 42 | 14.35 | 2973 | 1792 | 1.94 / 138.30 | 2 | 2 |
3 | 13 | 1585.44 | 20 | 14.51 | 2472 | 717 | 2.66 / 139.01 | 2 | 2 |
4 | 13 | 880.48 | 20 | 14.75 | 1547 | 456 | 3.11 / 139.47 | 2 | 2 |
5 | 13 | 307.44 | 20 | 15.00 | 772 | 232 | 3.34 / 139.70 | 2 | 2 |
6 | 8 | -0.20 | 175 | 15.11 | 327 | 865 | 4.21 / 140.57 | 2 | 3 |
Average= | 4.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.08 | 20 | 15.06 | 501 | 151 | 0.15 / 132.30 | 2 | 2 |
2 | 7 | 2003.64 | 42 | 14.36 | 2971 | 1792 | 1.94 / 134.09 | 2 | 2 |
3 | 13 | 1586.92 | 20 | 14.52 | 2467 | 716 | 2.66 / 134.80 | 2 | 2 |
4 | 13 | 1018.84 | 20 | 14.70 | 1715 | 504 | 3.16 / 135.31 | 2 | 2 |
5 | 13 | 180.20 | 20 | 15.07 | 593 | 179 | 3.34 / 135.49 | 2 | 2 |
6 | 8 | 0.64 | 175 | 15.11 | 329 | 870 | 4.21 / 136.36 | 2 | 3 |
Average= | 4.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.52 | 20 | 15.06 | 495 | 149 | 0.15 / 127.89 | 2 | 2 |
2 | 7 | 2001.64 | 42 | 14.37 | 2973 | 1794 | 1.94 / 129.68 | 2 | 2 |
3 | 13 | 1588.00 | 20 | 14.52 | 2470 | 717 | 2.66 / 130.40 | 2 | 2 |
4 | 13 | 1006.96 | 20 | 14.71 | 1703 | 501 | 3.16 / 130.90 | 2 | 2 |
5 | 13 | 429.68 | 20 | 14.95 | 941 | 281 | 3.44 / 131.18 | 2 | 2 |
6 | 13 | 10.32 | 20 | 15.15 | 350 | 106 | 3.55 / 131.29 | 2 | 2 |
7 | 8 | 0.36 | 175 | 15.11 | 325 | 859 | 4.41 / 132.15 | 2 | 5 |
Average= | 4.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.40 | 21 | 15.07 | 487 | 154 | 0.15 / 123.73 | 2 | 2 |
2 | 7 | 2002.36 | 42 | 14.37 | 2977 | 1797 | 1.95 / 125.52 | 2 | 2 |
3 | 13 | 1579.52 | 20 | 14.52 | 2471 | 718 | 2.67 / 126.24 | 2 | 2 |
4 | 13 | 868.80 | 20 | 14.76 | 1528 | 451 | 3.12 / 126.69 | 2 | 2 |
5 | 13 | 169.92 | 20 | 15.08 | 578 | 174 | 3.29 / 126.87 | 2 | 2 |
6 | 8 | 0.04 | 175 | 15.12 | 329 | 871 | 4.16 / 127.74 | 2 | 2 |
Average= | 4.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.12 | 20 | 15.07 | 484 | 146 | 0.15 / 119.48 | 2 | 2 |
2 | 7 | 2003.20 | 42 | 14.37 | 2970 | 1793 | 1.94 / 121.27 | 2 | 2 |
3 | 13 | 1589.88 | 20 | 14.52 | 2470 | 717 | 2.66 / 121.99 | 2 | 2 |
4 | 13 | 1013.16 | 20 | 14.71 | 1708 | 502 | 3.16 / 122.49 | 2 | 2 |
5 | 13 | 287.16 | 20 | 15.03 | 736 | 221 | 3.38 / 122.71 | 2 | 2 |
6 | 8 | 0.20 | 175 | 15.12 | 325 | 860 | 4.24 / 123.57 | 2 | 3 |
Average= | 4.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.24 | 20 | 15.08 | 499 | 150 | 0.15 / 115.25 | 2 | 2 |
2 | 7 | 2003.80 | 42 | 14.36 | 2972 | 1792 | 1.94 / 117.05 | 2 | 2 |
3 | 13 | 1578.24 | 20 | 14.53 | 2442 | 710 | 2.65 / 117.75 | 2 | 2 |
4 | 13 | 995.24 | 20 | 14.71 | 1691 | 497 | 3.15 / 118.25 | 2 | 2 |
5 | 13 | 274.32 | 20 | 15.03 | 726 | 218 | 3.37 / 118.47 | 2 | 2 |
6 | 8 | 0.24 | 175 | 15.12 | 326 | 863 | 4.23 / 119.33 | 2 | 3 |
Average= | 4.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.12 | 20 | 15.07 | 489 | 147 | 0.15 / 111.14 | 2 | 2 |
2 | 7 | 2001.88 | 42 | 14.38 | 2968 | 1793 | 1.94 / 112.93 | 2 | 2 |
3 | 13 | 1455.60 | 20 | 14.58 | 2295 | 669 | 2.61 / 113.60 | 2 | 2 |
4 | 13 | 893.28 | 20 | 14.76 | 1562 | 461 | 3.07 / 114.06 | 2 | 2 |
5 | 13 | 188.00 | 20 | 15.08 | 596 | 180 | 3.25 / 114.24 | 2 | 2 |
6 | 8 | 0.04 | 175 | 15.13 | 326 | 863 | 4.11 / 115.10 | 2 | 2 |
Average= | 4.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.44 | 20 | 15.09 | 491 | 148 | 0.15 / 106.86 | 2 | 2 |
2 | 7 | 2004.20 | 43 | 14.38 | 2989 | 1848 | 2.00 / 108.71 | 2 | 2 |
3 | 13 | 1460.56 | 20 | 14.57 | 2299 | 670 | 2.67 / 109.38 | 2 | 2 |
4 | 13 | 898.32 | 20 | 14.76 | 1568 | 463 | 3.13 / 109.84 | 2 | 2 |
5 | 13 | 186.80 | 20 | 15.08 | 601 | 181 | 3.31 / 110.02 | 2 | 2 |
6 | 13 | 20.04 | 20 | 15.16 | 360 | 109 | 3.42 / 110.13 | 2 | 2 |
7 | 8 | 0.24 | 175 | 15.12 | 325 | 860 | 4.28 / 110.99 | 2 | 2 |
Average= | 4.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.08 | 20 | 15.09 | 490 | 148 | 0.15 / 102.62 | 2 | 2 |
2 | 7 | 2003.40 | 42 | 14.39 | 2973 | 1797 | 1.94 / 104.41 | 2 | 2 |
3 | 13 | 1587.36 | 20 | 14.54 | 2471 | 719 | 2.66 / 105.13 | 2 | 2 |
4 | 13 | 1008.48 | 20 | 14.72 | 1708 | 503 | 3.17 / 105.63 | 2 | 2 |
5 | 13 | 290.32 | 20 | 15.04 | 746 | 224 | 3.39 / 105.86 | 2 | 2 |
6 | 8 | 0.16 | 175 | 15.14 | 321 | 850 | 4.24 / 106.71 | 2 | 2 |
Average= | 4.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.72 | 21 | 15.09 | 492 | 156 | 0.16 / 98.46 | 2 | 2 |
2 | 7 | 2004.48 | 43 | 14.39 | 2970 | 1838 | 1.99 / 100.30 | 2 | 2 |
3 | 13 | 1449.88 | 20 | 14.58 | 2300 | 671 | 2.66 / 100.97 | 2 | 2 |
4 | 13 | 897.36 | 20 | 14.77 | 1564 | 462 | 3.13 / 101.43 | 2 | 2 |
5 | 13 | 175.76 | 20 | 15.10 | 590 | 178 | 3.30 / 101.61 | 2 | 2 |
6 | 8 | 0.24 | 175 | 15.14 | 325 | 861 | 4.17 / 102.47 | 2 | 3 |
Average= | 4.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.04 | 20 | 15.09 | 489 | 148 | 0.15 / 94.27 | 2 | 2 |
2 | 7 | 2002.16 | 42 | 14.39 | 2979 | 1800 | 1.95 / 96.07 | 2 | 2 |
3 | 13 | 1454.76 | 20 | 14.59 | 2301 | 671 | 2.62 / 96.74 | 2 | 2 |
4 | 13 | 897.00 | 20 | 14.77 | 1573 | 465 | 3.08 / 97.21 | 2 | 2 |
5 | 13 | 324.96 | 20 | 15.02 | 798 | 240 | 3.32 / 97.45 | 2 | 2 |
6 | 8 | 0.44 | 175 | 15.14 | 323 | 856 | 4.18 / 98.30 | 2 | 4 |
Average= | 4.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.68 | 21 | 15.10 | 490 | 155 | 0.16 / 90.04 | 2 | 2 |
2 | 7 | 2004.72 | 42 | 14.40 | 2999 | 1814 | 1.97 / 91.85 | 2 | 2 |
3 | 13 | 1595.76 | 20 | 14.55 | 2488 | 724 | 2.69 / 92.57 | 2 | 2 |
4 | 13 | 886.92 | 20 | 14.78 | 1554 | 459 | 3.15 / 93.03 | 2 | 2 |
5 | 13 | 318.64 | 20 | 15.03 | 788 | 237 | 3.39 / 93.27 | 2 | 2 |
6 | 8 | -0.08 | 175 | 15.15 | 322 | 854 | 4.24 / 94.12 | 2 | 2 |
Average= | 4.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.28 | 21 | 15.10 | 486 | 154 | 0.15 / 85.87 | 2 | 2 |
2 | 7 | 2003.84 | 43 | 14.40 | 2986 | 1849 | 2.00 / 87.72 | 2 | 2 |
3 | 13 | 1448.24 | 20 | 14.60 | 2281 | 666 | 2.67 / 88.38 | 2 | 2 |
4 | 13 | 895.28 | 20 | 14.78 | 1563 | 462 | 3.13 / 88.85 | 2 | 2 |
5 | 13 | 167.52 | 20 | 15.11 | 571 | 173 | 3.30 / 89.02 | 2 | 2 |
6 | 8 | 0.40 | 175 | 15.15 | 325 | 862 | 4.17 / 89.88 | 2 | 2 |
Average= | 4.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.84 | 20 | 15.10 | 475 | 143 | 0.14 / 81.63 | 2 | 2 |
2 | 3 | 1031.20 | 1 | 15.15 | 1874 | 28 | 0.17 / 81.66 | 2 | 2 |
3 | 7 | 2001.88 | 42 | 14.42 | 2975 | 1802 | 1.97 / 83.46 | 2 | 2 |
4 | 13 | 1580.12 | 20 | 14.57 | 2461 | 717 | 2.69 / 84.18 | 2 | 2 |
5 | 13 | 871.84 | 20 | 14.80 | 1538 | 455 | 3.15 / 84.63 | 2 | 2 |
6 | 13 | 300.28 | 20 | 15.05 | 760 | 229 | 3.37 / 84.86 | 2 | 2 |
7 | 8 | 0.16 | 175 | 15.16 | 322 | 854 | 4.23 / 85.71 | 2 | 8 |
Average= | 4.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.60 | 21 | 15.12 | 482 | 153 | 0.15 / 77.26 | 2 | 2 |
2 | 3 | 948.92 | -1 | 15.54 | 0 | 0 | 0.00 / 77.26 | 2 | 2 |
3 | 7 | 2001.28 | 42 | 14.42 | 2971 | 1799 | 1.95 / 79.06 | 2 | 2 |
4 | 13 | 1592.60 | 20 | 14.57 | 2473 | 721 | 2.67 / 79.78 | 2 | 2 |
5 | 13 | 1017.68 | 20 | 14.74 | 1718 | 506 | 3.18 / 80.29 | 2 | 2 |
6 | 13 | 294.60 | 20 | 15.06 | 753 | 227 | 3.41 / 80.52 | 2 | 2 |
7 | 13 | 33.48 | 20 | 15.18 | 375 | 114 | 3.52 / 80.63 | 2 | 2 |
8 | 8 | -0.08 | 175 | 15.15 | 323 | 856 | 4.38 / 81.49 | 2 | 8 |
Average= | 4.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.76 | 21 | 15.13 | 472 | 150 | 0.15 / 72.98 | 2 | 2 |
2 | 3 | 1020.80 | 1 | 15.22 | 1865 | 28 | 0.18 / 73.01 | 2 | 2 |
3 | 7 | 2004.16 | 42 | 14.42 | 2990 | 1811 | 1.99 / 74.82 | 2 | 2 |
4 | 13 | 1580.52 | 20 | 14.58 | 2467 | 719 | 2.71 / 75.54 | 2 | 2 |
5 | 13 | 995.44 | 20 | 14.75 | 1687 | 498 | 3.21 / 76.04 | 2 | 2 |
6 | 13 | 275.72 | 20 | 15.07 | 723 | 218 | 3.42 / 76.25 | 2 | 2 |
7 | 8 | 0.32 | 175 | 15.16 | 322 | 854 | 4.28 / 77.11 | 2 | 3 |
Average= | 4.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.96 | 21 | 15.13 | 477 | 152 | 0.15 / 68.78 | 2 | 2 |
2 | 7 | 2003.12 | 42 | 14.43 | 2981 | 1807 | 1.96 / 70.59 | 2 | 2 |
3 | 13 | 1583.60 | 20 | 14.58 | 2458 | 717 | 2.67 / 71.30 | 2 | 2 |
4 | 13 | 872.28 | 20 | 14.80 | 1534 | 454 | 3.13 / 71.76 | 2 | 2 |
5 | 13 | 302.92 | 20 | 15.06 | 760 | 229 | 3.36 / 71.99 | 2 | 2 |
6 | 8 | -0.16 | 175 | 15.17 | 318 | 844 | 4.20 / 72.83 | 2 | 3 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.20 | 21 | 15.14 | 465 | 148 | 0.15 / 64.61 | 2 | 2 |
2 | 7 | 2003.28 | 42 | 14.43 | 2983 | 1808 | 1.96 / 66.42 | 2 | 2 |
3 | 13 | 1569.92 | 19 | 14.59 | 2452 | 680 | 2.64 / 67.10 | 2 | 2 |
4 | 13 | 996.76 | 19 | 14.76 | 1691 | 474 | 3.11 / 67.57 | 2 | 2 |
5 | 13 | 285.20 | 19 | 15.07 | 742 | 212 | 3.32 / 67.78 | 2 | 2 |
6 | 8 | 0.04 | 175 | 15.17 | 318 | 844 | 4.17 / 68.63 | 2 | 5 |
Average= | 4.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.84 | 22 | 15.13 | 476 | 158 | 0.16 / 60.34 | 2 | 2 |
2 | 7 | 2002.52 | 42 | 14.45 | 2971 | 1803 | 1.96 / 62.14 | 2 | 2 |
3 | 13 | 1590.76 | 19 | 14.59 | 2494 | 691 | 2.65 / 62.83 | 2 | 2 |
4 | 13 | 904.92 | 19 | 14.80 | 1575 | 443 | 3.10 / 63.27 | 2 | 2 |
5 | 13 | 341.88 | 19 | 15.05 | 813 | 232 | 3.33 / 63.51 | 2 | 2 |
6 | 13 | 38.72 | 19 | 15.19 | 379 | 109 | 3.44 / 63.62 | 2 | 2 |
7 | 8 | 0.24 | 175 | 15.17 | 319 | 847 | 4.28 / 64.46 | 2 | 7 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.40 | 20 | 15.14 | 472 | 143 | 0.14 / 56.01 | 2 | 2 |
2 | 3 | 1061.64 | 2 | 15.08 | 1886 | 57 | 0.20 / 56.07 | 2 | 2 |
3 | 7 | 2001.68 | 43 | 14.44 | 2982 | 1852 | 2.05 / 57.92 | 2 | 2 |
4 | 13 | 1450.20 | 19 | 14.63 | 2295 | 638 | 2.69 / 58.56 | 2 | 2 |
5 | 13 | 904.96 | 19 | 14.80 | 1579 | 444 | 3.13 / 59.00 | 2 | 2 |
6 | 13 | 328.04 | 19 | 15.06 | 791 | 226 | 3.36 / 59.23 | 2 | 2 |
7 | 13 | 34.08 | 19 | 15.20 | 376 | 109 | 3.47 / 59.34 | 2 | 2 |
8 | 8 | -0.12 | 175 | 15.17 | 317 | 842 | 4.31 / 60.18 | 2 | 7 |
Average= | 4.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.72 | 22 | 15.13 | 470 | 156 | 0.16 / 51.74 | 2 | 2 |
2 | 3 | 932.48 | -1 | 15.56 | 0 | 0 | 0.00 / 51.74 | 2 | 2 |
3 | 7 | 2001.68 | 42 | 14.45 | 2996 | 1818 | 1.97 / 53.56 | 2 | 2 |
4 | 13 | 1720.72 | 19 | 14.56 | 2649 | 733 | 2.71 / 54.29 | 2 | 2 |
5 | 13 | 982.32 | 19 | 14.78 | 1671 | 469 | 3.18 / 54.76 | 2 | 2 |
6 | 13 | 409.64 | 19 | 15.02 | 910 | 260 | 3.44 / 55.02 | 2 | 2 |
7 | 8 | 0.36 | 175 | 15.18 | 319 | 847 | 4.28 / 55.87 | 2 | 3 |
Average= | 3.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.28 | 22 | 15.14 | 466 | 155 | 0.16 / 47.19 | 2 | 2 |
2 | 7 | 2003.40 | 42 | 14.46 | 2975 | 1807 | 1.96 / 49.00 | 2 | 2 |
3 | 13 | 1588.84 | 19 | 14.60 | 2475 | 687 | 2.65 / 49.68 | 2 | 2 |
4 | 13 | 1008.52 | 19 | 14.77 | 1713 | 481 | 3.13 / 50.16 | 2 | 2 |
5 | 13 | 421.96 | 19 | 15.02 | 924 | 264 | 3.39 / 50.43 | 2 | 2 |
6 | 8 | 0.32 | 175 | 15.19 | 317 | 843 | 4.24 / 51.27 | 2 | 3 |
7 | 14 | 0.32 | 65 | 15.15 | 319 | 314 | 4.55 / 51.58 | 2 | 9 |
Average= | 3.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.00 | 22 | 15.14 | 480 | 160 | 0.16 / 42.96 | 2 | 2 |
2 | 3 | 965.72 | -1 | 15.57 | 0 | 0 | 0.00 / 42.96 | 2 | 2 |
3 | 3 | 1030.88 | 1 | 15.22 | 1882 | 29 | 0.19 / 42.99 | 2 | 2 |
4 | 7 | 2006.12 | 44 | 14.45 | 3001 | 1908 | 2.10 / 44.90 | 2 | 2 |
5 | 13 | 1450.24 | 19 | 14.64 | 2295 | 638 | 2.73 / 45.53 | 2 | 2 |
6 | 13 | 887.92 | 19 | 14.82 | 1557 | 438 | 3.17 / 45.97 | 2 | 2 |
7 | 13 | 298.44 | 19 | 15.08 | 750 | 215 | 3.39 / 46.19 | 2 | 2 |
8 | 8 | 0.32 | 175 | 15.18 | 319 | 847 | 4.24 / 47.03 | 2 | 3 |
Average= | 3.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.88 | 22 | 15.14 | 476 | 159 | 0.16 / 38.83 | 2 | 2 |
2 | 7 | 2003.44 | 44 | 14.46 | 2970 | 1890 | 2.05 / 40.72 | 2 | 2 |
3 | 13 | 1440.32 | 19 | 14.65 | 2266 | 631 | 2.68 / 41.35 | 2 | 2 |
4 | 13 | 872.72 | 19 | 14.83 | 1536 | 433 | 3.11 / 41.78 | 2 | 2 |
5 | 13 | 166.92 | 19 | 15.15 | 567 | 163 | 3.27 / 41.95 | 2 | 2 |
6 | 8 | 0.08 | 175 | 15.19 | 320 | 851 | 4.13 / 42.80 | 2 | 3 |
Average= | 3.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.96 | 21 | 15.15 | 469 | 149 | 0.15 / 34.62 | 2 | 2 |
2 | 3 | 1024.36 | 1 | 15.23 | 1887 | 29 | 0.18 / 34.64 | 2 | 2 |
3 | 7 | 2001.48 | 45 | 14.46 | 2996 | 1949 | 2.13 / 36.59 | 2 | 2 |
4 | 13 | 1436.52 | 19 | 14.66 | 2276 | 634 | 2.76 / 37.23 | 2 | 2 |
5 | 13 | 867.32 | 19 | 14.84 | 1530 | 431 | 3.19 / 37.66 | 2 | 2 |
6 | 13 | 157.08 | 19 | 15.16 | 556 | 160 | 3.35 / 37.82 | 2 | 2 |
7 | 8 | 0.24 | 175 | 15.19 | 321 | 853 | 4.21 / 38.67 | 2 | 4 |
Average= | 3.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.16 | 22 | 15.14 | 470 | 157 | 0.16 / 30.39 | 2 | 2 |
2 | 3 | 936.00 | -1 | 15.57 | 0 | 0 | 0.00 / 30.39 | 2 | 2 |
3 | 7 | 2001.84 | 44 | 14.46 | 2985 | 1899 | 2.06 / 32.29 | 2 | 2 |
4 | 13 | 1433.76 | 22 | 14.65 | 2271 | 732 | 2.79 / 33.02 | 2 | 2 |
5 | 13 | 734.36 | 22 | 14.88 | 1357 | 444 | 3.23 / 33.46 | 2 | 2 |
6 | 13 | 74.72 | 22 | 15.19 | 438 | 146 | 3.38 / 33.61 | 2 | 2 |
7 | 8 | 0.20 | 175 | 15.19 | 322 | 856 | 4.23 / 34.47 | 2 | 3 |
Average= | 3.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.24 | 22 | 15.14 | 477 | 159 | 0.16 / 26.07 | 2 | 2 |
2 | 3 | 1032.16 | 1 | 15.21 | 1876 | 29 | 0.19 / 26.10 | 2 | 2 |
3 | 7 | 2003.28 | 45 | 14.46 | 2994 | 1948 | 2.14 / 28.05 | 2 | 2 |
4 | 13 | 1450.80 | 22 | 14.64 | 2299 | 740 | 2.88 / 28.79 | 2 | 2 |
5 | 13 | 741.52 | 22 | 14.88 | 1368 | 448 | 3.32 / 29.23 | 2 | 2 |
6 | 13 | 74.80 | 22 | 15.20 | 435 | 145 | 3.47 / 29.38 | 2 | 2 |
7 | 8 | 0.16 | 175 | 15.19 | 321 | 853 | 4.32 / 30.23 | 2 | 3 |
Average= | 3.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.96 | 23 | 15.14 | 492 | 171 | 0.17 / 21.80 | 2 | 2 |
2 | 3 | 973.32 | -1 | 15.60 | 0 | 0 | 0.00 / 21.80 | 2 | 2 |
3 | 7 | 2001.12 | 44 | 14.48 | 2970 | 1892 | 2.06 / 23.69 | 2 | 2 |
4 | 13 | 1436.28 | 22 | 14.65 | 2267 | 731 | 2.79 / 24.42 | 2 | 2 |
5 | 13 | 860.64 | 22 | 14.84 | 1519 | 496 | 3.29 / 24.92 | 2 | 2 |
6 | 13 | 65.96 | 22 | 15.20 | 423 | 141 | 3.43 / 25.06 | 2 | 2 |
7 | 8 | 0.24 | 175 | 15.19 | 321 | 853 | 4.28 / 25.91 | 2 | 6 |
Average= | 3.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.04 | 23 | 15.15 | 482 | 168 | 0.17 / 17.44 | 2 | 2 |
2 | 3 | 966.92 | -1 | 15.58 | 0 | 0 | 0.00 / 17.44 | 2 | 2 |
3 | 7 | 2003.00 | 44 | 14.49 | 2976 | 1897 | 2.07 / 19.33 | 2 | 2 |
4 | 13 | 1556.40 | 22 | 14.62 | 2432 | 782 | 2.85 / 20.11 | 2 | 2 |
5 | 13 | 825.64 | 22 | 14.85 | 1480 | 484 | 3.33 / 20.60 | 2 | 2 |
6 | 13 | 107.36 | 22 | 15.18 | 487 | 163 | 3.49 / 20.76 | 2 | 2 |
7 | 8 | 0.36 | 175 | 15.19 | 325 | 864 | 4.36 / 21.62 | 2 | 3 |
Average= | 3.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.96 | 20 | 15.15 | 478 | 145 | 0.14 / 13.41 | 2 | 2 |
2 | 3 | 1067.04 | 2 | 15.08 | 1896 | 57 | 0.20 / 13.46 | 2 | 2 |
3 | 7 | 1516.00 | 44 | 14.69 | 2376 | 1536 | 1.74 / 15.00 | 2 | 2 |
4 | 13 | 1253.68 | 22 | 14.77 | 2046 | 665 | 2.40 / 15.66 | 2 | 2 |
5 | 13 | 669.80 | 22 | 14.96 | 1269 | 418 | 2.82 / 16.08 | 2 | 2 |
6 | 8 | 0.12 | 240 | 15.21 | 325 | 1186 | 4.01 / 17.27 | 2 | 2 |
Average= | 3.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.56 | 23 | 15.13 | 499 | 174 | 0.17 / 9.42 | 2 | 2 |
2 | 3 | 874.04 | -2 | 15.57 | 0 | 0 | 0.00 / 9.42 | 2 | 2 |
3 | 3 | 957.16 | -1 | 15.59 | 0 | 0 | 0.00 / 9.42 | 2 | 2 |
4 | 7 | 1511.76 | 44 | 14.69 | 2374 | 1534 | 1.71 / 10.95 | 2 | 2 |
5 | 13 | 1382.04 | 22 | 14.73 | 2217 | 718 | 2.43 / 11.67 | 2 | 2 |
6 | 13 | 650.32 | 22 | 14.96 | 1242 | 409 | 2.84 / 12.08 | 2 | 2 |
7 | 8 | 0.32 | 240 | 15.20 | 324 | 1182 | 4.02 / 13.26 | 2 | 2 |
Average= | 3.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.92 | 24 | 15.15 | 487 | 177 | 0.18 / 5.29 | 2 | 2 |
2 | 3 | 946.52 | -1 | 15.57 | 0 | 0 | 0.00 / 5.29 | 2 | 2 |
3 | 7 | 1506.48 | 74 | 14.61 | 2358 | 2549 | 2.73 / 7.84 | 2 | 2 |
4 | 13 | 167.32 | 25 | 15.16 | 572 | 217 | 2.94 / 8.05 | 2 | 2 |
5 | 8 | 0.12 | 240 | 15.18 | 327 | 1191 | 4.13 / 9.24 | 2 | 8 |
Average= | 3.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.64 | 25 | 15.31 | 472 | 181 | 0.18 / 2.06 | 2 | 2 |
2 | 3 | 955.16 | -1 | 15.56 | 0 | 0 | 0.00 / 2.06 | 2 | 2 |
3 | 7 | 997.40 | 74 | 14.79 | 1691 | 1851 | 2.03 / 3.91 | 2 | 2 |
4 | 8 | 0.12 | 240 | 15.21 | 328 | 1197 | 3.23 / 5.11 | 2 | 2 |
Average= | 2.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 97.40 | 25 | 15.49 | 473 | 183 | 0.18 / 0.18 | 2 | 2 |
2 | 7 | 106.96 | 74 | 15.45 | 475 | 543 | 0.73 / 0.73 | 2 | 2 |
3 | 8 | -0.04 | 240 | 15.41 | 312 | 1154 | 1.88 / 1.88 | 2 | 5 |
Average= | 1.88 (KJ/cycle) |