SIO Argo Site:
Pump Diagnostics Page   



Serial= 8570 WMO= 3901469

Return

←PreviousNext→

Bug in float firmware: Transmitted values shaded red are not valid


Cycle 269 GMT 21/12/2024 23:38: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.84 25 15.08 2 1 0.00 / 1139.47 3 3
2 5 1306.08 8 15.45 3 0 0.00 / 1139.47 3 3
3 7 2012.40 44 14.07 3050 1888 1.89 / 1141.36 3 3
4 13 1880.44 22 14.10 2901 900 2.79 / 1142.26 3 3
5 13 1021.24 22 14.45 1735 552 3.34 / 1142.81 3 3
6 13 318.04 22 14.81 791 258 3.60 / 1143.07 3 3
7 8 0.16 165 14.98 315 779 4.38 / 1143.85 3 3
Average= 4.24
(KJ/cycle)

Cycle 268 GMT 12/12/2024 0:26: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.48 25 15.08 2 1 0.00 / 1135.07 3 3
2 7 2010.36 44 14.09 3048 1890 1.89 / 1136.96 3 3
3 13 1751.32 22 14.15 2739 853 2.74 / 1137.81 3 3
4 13 1041.56 22 14.43 1766 561 3.30 / 1138.37 3 3
5 13 463.64 22 14.72 982 318 3.62 / 1138.69 3 3
6 8 0.08 165 14.97 314 776 4.40 / 1139.47 3 3
Average= 4.24
(KJ/cycle)

Cycle 267 GMT 2/12/2024 1:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.40 25 15.08 2 1 0.00 / 1130.74 3 3
2 7 2005.20 44 14.09 3049 1890 1.89 / 1132.63 3 3
3 13 1748.52 22 14.15 2731 850 2.74 / 1133.48 3 3
4 13 1035.84 22 14.43 1760 559 3.30 / 1134.04 3 3
5 13 327.44 22 14.80 797 260 3.56 / 1134.30 3 3
6 8 0.24 165 14.97 313 773 4.33 / 1135.07 3 3
Average= 4.24
(KJ/cycle)

Cycle 266 GMT 22/11/2024 2:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.84 25 15.08 2 1 0.00 / 1126.41 3 3
2 7 2010.52 44 14.09 3044 1887 1.89 / 1128.29 3 3
3 13 1744.16 22 14.15 2718 846 2.73 / 1129.14 3 3
4 13 1024.48 22 14.44 1750 556 3.29 / 1129.70 3 3
5 13 324.16 22 14.80 797 260 3.55 / 1129.96 3 3
6 8 0.00 165 14.97 317 783 4.33 / 1130.74 3 3
Average= 4.23
(KJ/cycle)

Cycle 265 GMT 12/11/2024 3:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.72 25 15.09 3 1 0.00 / 1121.98 3 3
2 7 2008.44 44 14.07 3055 1891 1.89 / 1123.87 3 3
3 13 1740.52 22 14.15 2717 846 2.74 / 1124.72 3 3
4 13 1168.20 22 14.37 1934 611 3.35 / 1125.33 3 3
5 13 428.60 22 14.75 922 299 3.65 / 1125.63 3 3
6 8 0.12 165 14.98 314 776 4.42 / 1126.41 3 3
Average= 4.23
(KJ/cycle)

Cycle 264 GMT 2/11/2024 4:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.44 24 15.08 2 1 0.00 / 1117.58 3 3
2 10 1001.52 3 15.33 4 0 0.00 / 1117.58 3 3
3 3 946.36 -1 15.36 0 0 0.00 / 1117.58 3 3
4 7 2008.00 44 14.07 3059 1894 1.89 / 1119.47 3 3
5 13 1742.32 22 14.15 2714 845 2.74 / 1120.32 3 3
6 13 1147.40 22 14.39 1909 604 3.34 / 1120.92 3 3
7 13 406.88 22 14.76 890 289 3.63 / 1121.21 3 3
8 8 0.04 165 14.98 311 769 4.40 / 1121.98 3 3
Average= 4.23
(KJ/cycle)

Cycle 263 GMT 23/10/2024 6: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.04 24 15.08 2 1 0.00 / 1113.23 3 3
2 7 2012.60 44 14.08 3059 1895 1.90 / 1115.12 3 3
3 13 1748.40 22 14.15 2729 850 2.75 / 1115.97 3 3
4 13 1041.84 22 14.43 1776 564 3.31 / 1116.54 3 3
5 13 331.24 22 14.80 808 263 3.57 / 1116.80 3 3
6 8 0.08 165 14.97 316 781 4.35 / 1117.58 3 3
Average= 4.23
(KJ/cycle)

Cycle 262 GMT 13/10/2024 6:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.32 25 15.08 2 1 0.00 / 1108.91 3 3
2 3 966.92 -1 15.37 0 0 0.00 / 1108.91 3 3
3 7 2011.84 44 14.08 3044 1886 1.89 / 1110.79 3 3
4 13 1749.80 22 14.15 2729 850 2.74 / 1111.64 3 3
5 13 1028.84 22 14.44 1746 555 3.29 / 1112.20 3 3
6 13 318.76 22 14.81 782 255 3.55 / 1112.45 3 3
7 8 0.12 165 14.97 313 773 4.32 / 1113.23 3 3
Average= 4.23
(KJ/cycle)

Cycle 261 GMT 3/10/2024 7:35:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.72 24 15.08 3 1 0.00 / 1104.54 3 3
2 3 1032.20 1 15.36 4 0 0.00 / 1104.54 3 3
3 7 2008.92 44 14.08 3043 1885 1.89 / 1106.43 3 3
4 13 1740.12 22 14.15 2719 846 2.73 / 1107.27 3 3
5 13 1036.36 22 14.44 1764 560 3.29 / 1107.83 3 3
6 13 451.36 22 14.73 964 312 3.61 / 1108.14 3 3
7 8 -0.08 165 14.97 309 763 4.37 / 1108.91 3 3
Average= 4.23
(KJ/cycle)

Cycle 260 GMT 23/ 9/2024 8:50: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.32 24 15.08 2 1 0.00 / 1100.11 3 3
2 7 2012.24 44 14.07 3052 1889 1.89 / 1102.00 3 3
3 13 1748.28 22 14.14 2731 850 2.74 / 1102.85 3 3
4 13 1165.80 22 14.37 1935 612 3.35 / 1103.46 3 3
5 13 425.68 22 14.74 940 305 3.66 / 1103.77 3 3
6 8 0.00 165 14.97 313 773 4.43 / 1104.54 3 3
Average= 4.23
(KJ/cycle)

Cycle 259 GMT 13/ 9/2024 9:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.48 24 15.07 2 1 0.00 / 1095.60 3 3
2 3 1026.60 1 15.36 3 0 0.00 / 1095.60 3 3
3 7 2011.96 44 14.07 3048 1887 1.89 / 1097.49 3 3
4 13 1881.20 22 14.11 2901 901 2.79 / 1098.39 3 3
5 13 1141.04 22 14.39 1896 600 3.39 / 1098.99 3 3
6 13 545.68 22 14.67 1087 351 3.74 / 1099.34 3 3
7 8 0.04 165 14.97 313 773 4.51 / 1100.11 3 3
Average= 4.23
(KJ/cycle)

Cycle 258 GMT 3/ 9/2024 10:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.84 25 15.07 2 1 0.00 / 1091.24 3 3
2 3 958.36 -1 15.36 0 0 0.00 / 1091.24 3 3
3 7 2009.12 44 14.06 3045 1884 1.88 / 1093.13 3 3
4 13 1744.00 22 14.15 2720 847 2.73 / 1093.97 3 3
5 13 1012.40 22 14.45 1718 546 3.28 / 1094.52 3 3
6 13 434.52 22 14.73 953 309 3.59 / 1094.83 3 3
7 8 0.08 165 14.97 312 771 4.36 / 1095.60 3 3
Average= 4.23
(KJ/cycle)

Cycle 257 GMT 24/ 8/2024 11:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.04 25 15.07 2 1 0.00 / 1086.82 3 3
2 7 2005.16 44 14.07 3051 1889 1.89 / 1088.71 3 3
3 13 1747.76 22 14.15 2725 848 2.74 / 1089.56 3 3
4 13 1167.32 22 14.37 1941 614 3.35 / 1090.17 3 3
5 13 429.24 22 14.74 937 304 3.66 / 1090.47 3 3
6 8 0.04 165 14.97 310 766 4.42 / 1091.24 3 3
Average= 4.23
(KJ/cycle)

Cycle 256 GMT 14/ 8/2024 12:56: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.88 24 15.06 2 1 0.00 / 1082.42 3 3
2 7 2005.16 44 14.07 3039 1881 1.88 / 1084.31 3 3
3 13 1748.80 22 14.14 2723 847 2.73 / 1085.15 3 3
4 13 1167.40 22 14.37 1929 610 3.34 / 1085.76 3 3
5 13 423.20 22 14.74 930 302 3.64 / 1086.06 3 3
6 8 0.04 165 14.96 306 755 4.40 / 1086.82 3 3
Average= 4.23
(KJ/cycle)

Cycle 255 GMT 4/ 8/2024 13:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.16 24 15.06 2 1 0.00 / 1078.03 3 3
2 7 2004.52 44 14.09 3041 1885 1.89 / 1079.91 3 3
3 13 1736.20 22 14.15 2703 841 2.73 / 1080.75 3 3
4 13 1161.20 22 14.37 1925 609 3.34 / 1081.36 3 3
5 13 412.20 22 14.74 904 293 3.63 / 1081.65 3 3
6 8 -0.08 165 14.95 312 770 4.40 / 1082.42 3 3
Average= 4.23
(KJ/cycle)

Cycle 254 GMT 25/ 7/2024 14:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 24 15.05 2 1 0.00 / 1073.70 3 3
2 7 2005.00 44 14.09 3047 1889 1.89 / 1075.59 3 3
3 13 1745.52 22 14.14 2726 848 2.74 / 1076.44 3 3
4 13 1026.04 22 14.43 1744 554 3.29 / 1076.99 3 3
5 13 321.16 22 14.79 787 256 3.55 / 1077.25 3 3
6 8 0.00 165 14.95 314 775 4.32 / 1078.02 3 3
Average= 4.23
(KJ/cycle)

Cycle 253 GMT 15/ 7/2024 15:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.88 24 15.05 2 1 0.00 / 1069.32 3 3
2 7 2011.92 44 14.08 3049 1889 1.89 / 1071.21 3 3
3 13 1747.36 22 14.14 2724 847 2.74 / 1072.05 3 3
4 13 1037.92 22 14.43 1763 560 3.30 / 1072.61 3 3
5 13 455.60 22 14.71 970 314 3.61 / 1072.93 3 3
6 8 -0.04 165 14.95 314 775 4.39 / 1073.70 3 3
Average= 4.23
(KJ/cycle)

Cycle 252 GMT 5/ 7/2024 16:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.72 24 15.05 1 0 0.00 / 1064.97 3 3
2 7 2004.20 44 14.09 3025 1875 1.88 / 1066.84 3 3
3 13 1734.60 22 14.15 2710 844 2.72 / 1067.69 3 3
4 13 1019.20 22 14.43 1732 550 3.27 / 1068.24 3 3
5 13 426.32 22 14.72 932 302 3.57 / 1068.54 3 3
6 8 -0.12 165 14.94 316 779 4.35 / 1069.32 3 3
Average= 4.23
(KJ/cycle)

Cycle 251 GMT 25/ 6/2024 17:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.32 24 15.05 2 1 0.00 / 1060.66 3 3
2 7 2003.60 44 14.09 3039 1884 1.88 / 1062.54 3 3
3 13 1733.84 22 14.15 2710 844 2.73 / 1063.39 3 3
4 13 1022.04 22 14.42 1740 552 3.28 / 1063.94 3 3
5 13 308.52 22 14.79 776 252 3.53 / 1064.19 3 3
6 8 0.20 165 14.94 315 777 4.31 / 1064.97 3 3
Average= 4.23
(KJ/cycle)

Cycle 250 GMT 15/ 6/2024 18:11: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.60 25 15.05 2 1 0.00 / 1056.19 3 3
2 7 2010.68 44 14.08 3048 1888 1.89 / 1058.08 3 3
3 13 1881.44 22 14.11 2897 899 2.79 / 1058.98 3 3
4 13 1137.28 22 14.37 1894 599 3.39 / 1059.58 3 3
5 13 404.00 22 14.73 899 291 3.68 / 1059.87 3 3
6 8 0.12 165 14.94 319 786 4.46 / 1060.66 3 3
Average= 4.23
(KJ/cycle)

Cycle 249 GMT 5/ 6/2024 19: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.92 25 15.05 2 1 0.00 / 1051.89 3 3
2 7 2010.96 44 14.10 3039 1885 1.89 / 1053.77 3 3
3 13 1627.92 22 14.18 2563 800 2.69 / 1054.57 3 3
4 13 1066.04 22 14.41 1800 571 3.26 / 1055.14 3 3
5 13 342.32 22 14.76 816 265 3.52 / 1055.41 3 3
6 8 -0.20 165 14.94 318 784 4.31 / 1056.19 3 3
Average= 4.22
(KJ/cycle)

Cycle 248 GMT 26/ 5/2024 20: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.24 25 15.04 2 1 0.00 / 1047.47 3 3
2 7 2006.36 44 14.07 3048 1887 1.89 / 1049.36 3 3
3 13 1877.40 22 14.10 2878 893 2.78 / 1050.25 3 3
4 13 1015.40 22 14.43 1732 550 3.33 / 1050.80 3 3
5 13 422.96 22 14.72 928 301 3.63 / 1051.10 3 3
6 8 0.00 165 14.94 318 784 4.41 / 1051.89 3 3
Average= 4.22
(KJ/cycle)

Cycle 247 GMT 16/ 5/2024 21: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.64 24 15.05 1 0 0.00 / 1043.16 3 3
2 7 2010.68 44 14.08 3048 1888 1.89 / 1045.04 3 3
3 13 1745.16 22 14.13 2721 846 2.73 / 1045.89 3 3
4 13 1024.32 22 14.42 1748 555 3.29 / 1046.45 3 3
5 13 303.32 22 14.78 761 247 3.54 / 1046.69 3 3
6 8 0.00 165 14.93 317 781 4.32 / 1047.47 3 3
Average= 4.22
(KJ/cycle)

Cycle 246 GMT 6/ 5/2024 21:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.08 24 15.05 2 1 0.00 / 1038.85 3 3
2 7 2009.20 44 14.07 3048 1887 1.89 / 1040.73 3 3
3 13 1741.88 22 14.14 2710 843 2.73 / 1041.58 3 3
4 13 1024.44 22 14.42 1745 554 3.28 / 1042.13 3 3
5 13 308.92 22 14.78 769 250 3.53 / 1042.38 3 3
6 8 -0.08 165 14.94 315 777 4.31 / 1043.16 3 3
Average= 4.22
(KJ/cycle)

Cycle 245 GMT 26/ 4/2024 22:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.76 25 15.05 2 1 0.00 / 1034.55 3 3
2 3 973.52 -1 15.33 0 0 0.00 / 1034.55 3 3
3 7 2005.16 44 14.07 3035 1879 1.88 / 1036.43 3 3
4 13 1736.92 22 14.14 2707 842 2.72 / 1037.27 3 3
5 13 1018.08 22 14.43 1734 550 3.27 / 1037.82 3 3
6 13 297.60 22 14.78 758 246 3.52 / 1038.07 3 3
7 8 -0.08 165 14.94 314 774 4.29 / 1038.85 3 3
Average= 4.22
(KJ/cycle)

Cycle 244 GMT 16/ 4/2024 23:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.96 25 15.05 1 0 0.00 / 1030.25 3 3
2 3 1032.12 1 15.34 3 0 0.00 / 1030.25 3 3
3 7 2003.00 44 14.08 3035 1880 1.88 / 1032.13 3 3
4 13 1745.68 22 14.14 2724 847 2.73 / 1032.98 3 3
5 13 1015.84 22 14.42 1734 550 3.28 / 1033.53 3 3
6 13 302.28 22 14.78 765 249 3.53 / 1033.78 3 3
7 8 -0.04 165 14.94 313 772 4.30 / 1034.55 3 3
Average= 4.22
(KJ/cycle)

Cycle 243 GMT 6/ 4/2024 23:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.04 24 15.04 2 1 0.00 / 1025.98 3 3
2 7 2013.60 44 14.07 3044 1884 1.89 / 1027.87 3 3
3 13 1626.48 22 14.17 2568 801 2.69 / 1028.67 3 3
4 13 1054.28 22 14.40 1785 565 3.25 / 1029.23 3 3
5 13 324.44 22 14.76 793 258 3.51 / 1029.49 3 3
6 8 0.00 165 14.94 310 764 4.27 / 1030.25 3 3
Average= 4.22
(KJ/cycle)

Cycle 242 GMT 28/ 3/2024 0:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.24 24 15.03 1 0 0.00 / 1021.49 3 3
2 7 2007.92 44 14.07 3040 1882 1.88 / 1023.37 3 3
3 13 1745.28 22 14.13 2722 846 2.73 / 1024.22 3 3
4 13 1034.20 22 14.41 1758 557 3.29 / 1024.78 3 3
5 13 448.76 22 14.69 959 310 3.60 / 1025.09 3 3
6 13 30.36 22 14.94 350 115 3.71 / 1025.20 3 3
7 8 -0.04 165 14.92 316 778 4.49 / 1025.98 3 3
Average= 4.22
(KJ/cycle)

Cycle 241 GMT 18/ 3/2024 1:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.40 24 15.04 2 1 0.00 / 1017.05 3 3
2 7 2005.52 44 14.06 3046 1884 1.89 / 1018.94 3 3
3 13 1748.32 22 14.13 2728 848 2.73 / 1019.78 3 3
4 13 1025.20 22 14.41 1748 554 3.29 / 1020.34 3 3
5 13 309.72 22 14.77 775 252 3.54 / 1020.59 3 3
6 13 34.48 22 14.94 363 119 3.66 / 1020.71 3 3
7 8 -0.20 165 14.92 318 783 4.44 / 1021.49 3 3
Average= 4.22
(KJ/cycle)

Cycle 240 GMT 8/ 3/2024 2: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.92 24 15.04 1 0 0.00 / 1012.65 3 3
2 7 2004.88 44 14.07 3040 1882 1.88 / 1014.54 3 3
3 13 1874.16 22 14.09 2892 896 2.78 / 1015.43 3 3
4 13 1133.84 22 14.36 1889 597 3.38 / 1016.03 3 3
5 13 278.08 22 14.78 736 239 3.61 / 1016.27 3 3
6 8 -0.08 165 14.93 318 783 4.40 / 1017.05 3 3
Average= 4.22
(KJ/cycle)

Cycle 239 GMT 27/ 2/2024 2:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.16 24 15.04 2 1 0.00 / 1008.43 3 3
2 7 2002.92 44 14.09 3037 1883 1.88 / 1010.31 3 3
3 13 1613.20 22 14.18 2529 789 2.67 / 1011.10 3 3
4 13 1056.00 22 14.39 1784 565 3.24 / 1011.66 3 3
5 13 218.96 22 14.82 643 210 3.45 / 1011.87 3 3
6 8 -0.16 165 14.92 317 780 4.23 / 1012.65 3 3
Average= 4.22
(KJ/cycle)

Cycle 238 GMT 17/ 2/2024 3:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.56 24 15.04 2 1 0.00 / 1003.96 3 3
2 7 2004.12 44 14.08 3034 1880 1.88 / 1005.84 3 3
3 13 1737.12 22 14.14 2697 839 2.72 / 1006.68 3 3
4 13 1020.36 22 14.41 1739 551 3.27 / 1007.23 3 3
5 13 434.24 22 14.69 943 305 3.58 / 1007.54 3 3
6 13 13.32 22 14.94 333 109 3.68 / 1007.65 3 3
7 8 -0.16 165 14.91 316 777 4.46 / 1008.43 3 3
Average= 4.22
(KJ/cycle)

Cycle 237 GMT 7/ 2/2024 4: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.84 24 15.05 2 1 0.00 / 999.72 3 3
2 7 2004.48 44 14.07 3049 1888 1.89 / 1001.61 3 3
3 13 1610.72 22 14.18 2540 792 2.68 / 1002.40 3 3
4 13 912.60 22 14.46 1598 508 3.19 / 1002.91 3 3
5 13 348.64 22 14.73 835 271 3.46 / 1003.18 3 3
6 8 -0.08 165 14.92 319 785 4.24 / 1003.96 3 3
Average= 4.22
(KJ/cycle)

Cycle 236 GMT 28/ 1/2024 4:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.44 24 15.04 2 1 0.00 / 995.35 3 3
2 7 2003.40 44 14.08 3037 1881 1.88 / 997.23 3 3
3 13 1736.68 22 14.13 2719 845 2.73 / 998.08 3 3
4 13 1172.92 22 14.34 1943 613 3.34 / 998.69 3 3
5 13 300.88 22 14.77 766 249 3.59 / 998.94 3 3
6 8 -0.16 165 14.93 316 778 4.37 / 999.72 3 3
Average= 4.22
(KJ/cycle)

Cycle 235 GMT 18/ 1/2024 5:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.68 24 15.04 1 0 0.00 / 991.03 3 3
2 7 2010.00 44 14.10 3043 1888 1.89 / 992.92 3 3
3 13 1749.48 22 14.14 2722 847 2.73 / 993.76 3 3
4 13 1027.44 22 14.40 1755 556 3.29 / 994.32 3 3
5 13 315.12 22 14.75 789 256 3.55 / 994.58 3 3
6 8 0.00 165 14.92 315 775 4.32 / 995.35 3 3
Average= 4.22
(KJ/cycle)

Cycle 234 GMT 8/ 1/2024 6:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.04 24 15.04 2 1 0.00 / 986.60 3 3
2 7 2006.48 44 14.06 3041 1881 1.88 / 988.48 3 3
3 13 1875.56 22 14.09 2887 895 2.78 / 989.38 3 3
4 13 1117.40 22 14.36 1875 592 3.37 / 989.97 3 3
5 13 388.04 22 14.72 885 287 3.66 / 990.26 3 3
6 8 -0.08 165 14.93 313 771 4.43 / 991.03 3 3
Average= 4.22
(KJ/cycle)

Cycle 233 GMT 29/12/2023 7: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.76 24 15.04 2 1 0.00 / 982.17 3 3
2 7 2009.20 44 14.06 3051 1887 1.89 / 984.06 3 3
3 13 1746.96 22 14.13 2721 846 2.73 / 984.91 3 3
4 13 1031.32 22 14.40 1760 558 3.29 / 985.47 3 3
5 13 309.24 22 14.76 774 251 3.54 / 985.72 3 3
6 13 16.52 22 14.95 332 109 3.65 / 985.83 3 3
7 8 -0.20 165 14.92 315 775 4.43 / 986.60 3 3
Average= 4.22
(KJ/cycle)

Cycle 232 GMT 19/12/2023 7:48:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.52 24 15.04 2 1 0.00 / 977.88 3 3
2 7 2007.40 44 14.07 3033 1878 1.88 / 979.76 3 3
3 13 1742.00 22 14.14 2714 844 2.72 / 980.60 3 3
4 13 1026.12 22 14.40 1746 553 3.28 / 981.15 3 3
5 13 311.36 22 14.76 781 254 3.53 / 981.41 3 3
6 8 -0.16 165 14.93 311 766 4.30 / 982.17 3 3
Average= 4.22
(KJ/cycle)

Cycle 231 GMT 9/12/2023 8:29: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.40 24 15.04 2 1 0.00 / 973.54 3 3
2 7 2006.88 44 14.06 3048 1886 1.89 / 975.43 3 3
3 13 1621.40 22 14.17 2552 796 2.68 / 976.22 3 3
4 13 1053.36 22 14.39 1787 566 3.25 / 976.79 3 3
5 13 462.40 22 14.67 986 318 3.57 / 977.11 3 3
6 8 -0.16 165 14.92 313 771 4.34 / 977.88 3 3
Average= 4.21
(KJ/cycle)

Cycle 230 GMT 29/11/2023 9: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.16 24 15.03 2 1 0.00 / 969.18 3 3
2 7 2005.72 44 14.07 3036 1880 1.88 / 971.06 3 3
3 13 1739.64 22 14.14 2706 842 2.72 / 971.90 3 3
4 13 1032.72 22 14.41 1755 556 3.28 / 972.46 3 3
5 13 442.76 22 14.68 956 309 3.59 / 972.77 3 3
6 8 -0.04 165 14.92 314 773 4.36 / 973.54 3 3
Average= 4.21
(KJ/cycle)

Cycle 229 GMT 19/11/2023 9:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.36 24 15.03 2 1 0.00 / 964.92 3 3
2 7 2003.84 44 14.08 3036 1881 1.88 / 966.80 3 3
3 13 1599.96 22 14.18 2535 791 2.67 / 967.59 3 3
4 13 1032.24 22 14.40 1760 558 3.23 / 968.15 3 3
5 13 315.76 22 14.75 787 255 3.49 / 968.40 3 3
6 8 -0.12 165 14.92 316 778 4.26 / 969.18 3 3
Average= 4.21
(KJ/cycle)

Cycle 228 GMT 9/11/2023 10:51:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.88 24 15.03 1 0 0.00 / 960.48 3 3
2 7 2008.52 44 14.10 3040 1886 1.89 / 962.37 3 3
3 13 1879.28 22 14.11 2896 899 2.79 / 963.27 3 3
4 13 1132.56 22 14.36 1895 599 3.38 / 963.87 3 3
5 13 394.00 22 14.71 890 288 3.67 / 964.16 3 3
6 8 -0.04 165 14.92 310 763 4.44 / 964.92 3 3
Average= 4.21
(KJ/cycle)

Cycle 227 GMT 30/10/2023 11:29: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.36 24 15.04 2 1 0.00 / 956.12 3 3
2 7 2003.60 44 14.11 3038 1886 1.89 / 958.01 3 3
3 13 1741.12 22 14.15 2713 845 2.73 / 958.85 3 3
4 13 1028.48 22 14.40 1751 555 3.29 / 959.40 3 3
5 13 442.80 22 14.68 953 308 3.59 / 959.71 3 3
6 8 0.00 165 14.92 313 771 4.36 / 960.48 3 3
Average= 4.21
(KJ/cycle)

Cycle 226 GMT 20/10/2023 12:14: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.92 23 15.04 2 1 0.00 / 951.81 3 3
2 3 1019.24 1 15.34 3 0 0.00 / 951.81 3 3
3 7 2004.88 44 14.06 3044 1883 1.88 / 953.70 3 3
4 13 1614.60 22 14.18 2530 789 2.67 / 954.49 3 3
5 13 1187.16 22 14.32 1968 620 3.29 / 955.11 3 3
6 13 304.44 22 14.76 766 249 3.54 / 955.36 3 3
7 8 -0.12 165 14.92 310 763 4.31 / 956.12 3 3
Average= 4.21
(KJ/cycle)

Cycle 225 GMT 10/10/2023 12: 6: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.28 23 15.03 2 1 0.00 / 947.36 3 3
2 7 2008.32 44 14.08 3041 1884 1.88 / 949.24 3 3
3 13 1723.32 22 14.15 2694 839 2.72 / 950.08 3 3
4 13 1151.28 22 14.35 1921 606 3.33 / 950.68 3 3
5 13 534.84 22 14.63 1081 348 3.68 / 951.03 3 3
6 8 -0.04 165 14.93 317 781 4.46 / 951.81 3 3
Average= 4.21
(KJ/cycle)

Cycle 224 GMT 30/ 9/2023 12:59: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.48 24 15.03 2 1 0.00 / 942.97 3 3
2 7 2003.64 44 14.07 3037 1880 1.88 / 944.85 3 3
3 13 1741.80 22 14.14 2719 846 2.73 / 945.70 3 3
4 13 903.04 22 14.47 1581 503 3.23 / 946.20 3 3
5 13 350.92 22 14.74 847 275 3.50 / 946.47 3 3
6 13 22.32 22 14.95 346 114 3.62 / 946.59 3 3
7 8 -0.16 165 14.92 312 768 4.39 / 947.36 3 3
Average= 4.21
(KJ/cycle)

Cycle 223 GMT 20/ 9/2023 13:34:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.72 24 15.04 2 1 0.00 / 938.61 3 3
2 7 2010.56 44 14.07 3037 1880 1.88 / 940.49 3 3
3 13 1617.12 22 14.19 2546 795 2.68 / 941.29 3 3
4 13 920.48 22 14.45 1612 512 3.19 / 941.80 3 3
5 13 347.64 22 14.73 840 272 3.46 / 942.07 3 3
6 13 49.96 22 14.93 387 127 3.59 / 942.20 3 3
7 8 -0.20 165 14.91 312 768 4.36 / 942.97 3 3
Average= 4.21
(KJ/cycle)

Cycle 222 GMT 10/ 9/2023 14: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.16 23 15.05 2 1 0.00 / 934.23 3 3
2 3 1028.24 1 15.34 3 0 0.00 / 934.23 3 3
3 7 2002.96 44 14.11 3031 1882 1.88 / 936.12 3 3
4 13 1733.40 22 14.16 2698 840 2.72 / 936.96 3 3
5 13 1149.56 22 14.35 1915 605 3.33 / 937.56 3 3
6 13 399.20 22 14.70 903 292 3.62 / 937.85 3 3
7 8 -0.12 165 14.93 309 761 4.38 / 938.61 3 3
Average= 4.21
(KJ/cycle)

Cycle 221 GMT 31/ 8/2023 14:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.76 23 15.04 2 1 0.00 / 929.90 3 3
2 7 2009.68 45 14.08 3040 1926 1.93 / 931.82 3 3
3 13 1744.08 22 14.14 2720 846 2.77 / 932.67 3 3
4 13 1010.80 22 14.41 1728 548 3.32 / 933.22 3 3
5 13 293.20 22 14.77 763 248 3.57 / 933.46 3 3
6 8 0.00 165 14.93 312 769 4.34 / 934.23 3 3
Average= 4.21
(KJ/cycle)

Cycle 220 GMT 21/ 8/2023 15:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 24 15.04 2 1 0.00 / 925.44 3 3
2 7 2007.80 44 14.10 3043 1888 1.89 / 927.32 3 3
3 13 1737.76 22 14.16 2709 844 2.73 / 928.17 3 3
4 13 1017.16 22 14.41 1744 553 3.29 / 928.72 3 3
5 13 432.04 22 14.69 942 304 3.59 / 929.03 3 3
6 13 14.56 22 14.95 330 109 3.70 / 929.13 3 3
7 8 -0.36 165 14.92 309 761 4.46 / 929.90 3 3
Average= 4.21
(KJ/cycle)

Cycle 219 GMT 11/ 8/2023 15:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.92 24 15.04 1 0 0.00 / 921.10 3 3
2 7 2012.00 44 14.07 3048 1887 1.89 / 922.99 3 3
3 13 1743.96 22 14.14 2717 845 2.73 / 923.83 3 3
4 13 1031.08 22 14.41 1759 558 3.29 / 924.39 3 3
5 13 425.24 22 14.69 931 301 3.59 / 924.69 3 3
6 8 -0.12 165 14.93 303 746 4.34 / 925.44 3 3
Average= 4.21
(KJ/cycle)

Cycle 218 GMT 1/ 8/2023 16:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.68 24 15.03 2 1 0.00 / 916.80 3 3
2 7 2004.64 44 14.10 3043 1888 1.89 / 918.69 3 3
3 13 1742.52 22 14.16 2714 845 2.73 / 919.54 3 3
4 13 1026.60 22 14.41 1752 555 3.29 / 920.09 3 3
5 13 305.60 22 14.76 772 251 3.54 / 920.34 3 3
6 8 -0.08 165 14.92 307 756 4.30 / 921.10 3 3
Average= 4.21
(KJ/cycle)

Cycle 217 GMT 22/ 7/2023 17:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.56 24 15.03 1 0 0.00 / 912.47 3 3
2 7 2005.76 44 14.11 3046 1891 1.89 / 914.36 3 3
3 13 1735.00 22 14.16 2715 846 2.74 / 915.21 3 3
4 13 1003.32 22 14.42 1721 546 3.28 / 915.75 3 3
5 13 417.96 22 14.69 927 300 3.58 / 916.05 3 3
6 8 -0.04 165 14.92 305 751 4.33 / 916.80 3 3
Average= 4.21
(KJ/cycle)

Cycle 216 GMT 12/ 7/2023 18: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.68 24 15.03 2 1 0.00 / 908.16 3 3
2 7 2008.88 44 14.11 3046 1891 1.89 / 910.05 3 3
3 13 1749.56 22 14.15 2741 853 2.75 / 910.90 3 3
4 13 1031.20 22 14.40 1764 559 3.30 / 911.46 3 3
5 13 311.92 22 14.75 782 254 3.56 / 911.72 3 3
6 8 -0.16 165 14.92 306 753 4.31 / 912.47 3 3
Average= 4.20
(KJ/cycle)

Cycle 215 GMT 2/ 7/2023 18:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.72 24 15.04 2 1 0.00 / 903.85 3 3
2 7 2003.60 44 14.11 3051 1894 1.89 / 905.74 3 3
3 13 1612.68 22 14.19 2560 799 2.69 / 906.54 3 3
4 13 1182.60 22 14.33 1962 619 3.31 / 907.16 3 3
5 13 296.92 22 14.77 758 246 3.56 / 907.40 3 3
6 8 -0.20 165 14.92 306 753 4.31 / 908.16 3 3
Average= 4.20
(KJ/cycle)

Cycle 214 GMT 22/ 6/2023 19:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.52 24 15.04 1 0 0.00 / 899.55 3 3
2 7 2008.76 44 14.11 3039 1887 1.89 / 901.43 3 3
3 13 1740.32 22 14.16 2727 850 2.74 / 902.28 3 3
4 13 1021.00 22 14.41 1747 554 3.29 / 902.84 3 3
5 13 301.88 22 14.76 771 250 3.54 / 903.09 3 3
6 8 -0.20 165 14.93 308 759 4.30 / 903.85 3 3
Average= 4.20
(KJ/cycle)

Cycle 213 GMT 12/ 6/2023 19:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.56 24 15.03 1 0 0.00 / 895.16 3 3
2 7 2005.56 44 14.11 3036 1885 1.89 / 897.04 3 3
3 13 1742.20 22 14.16 2709 844 2.73 / 897.89 3 3
4 13 1140.68 22 14.35 1919 606 3.33 / 898.49 3 3
5 13 387.40 22 14.71 887 287 3.62 / 898.78 3 3
6 8 -0.12 165 14.93 312 769 4.39 / 899.55 3 3
Average= 4.20
(KJ/cycle)

Cycle 212 GMT 2/ 6/2023 20:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.28 24 15.04 1 0 0.00 / 890.88 3 3
2 7 2011.04 44 14.11 3052 1895 1.90 / 892.78 3 3
3 13 1610.92 22 14.20 2550 797 2.69 / 893.57 3 3
4 13 906.48 22 14.46 1597 508 3.20 / 894.08 3 3
5 13 217.28 22 14.82 644 210 3.41 / 894.29 3 3
6 13 45.16 22 14.93 376 124 3.53 / 894.41 3 3
7 8 -0.24 165 14.92 301 741 4.27 / 895.16 3 3
Average= 4.20
(KJ/cycle)

Cycle 211 GMT 23/ 5/2023 21: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.84 24 15.04 1 0 0.00 / 886.57 3 3
2 7 2009.68 44 14.11 3054 1896 1.90 / 888.47 3 3
3 13 1736.68 22 14.17 2710 845 2.74 / 889.32 3 3
4 13 1034.72 22 14.41 1767 560 3.30 / 889.88 3 3
5 13 310.92 22 14.76 784 255 3.56 / 890.13 3 3
6 8 0.00 165 14.93 305 751 4.31 / 890.88 3 3
Average= 4.20
(KJ/cycle)

Cycle 210 GMT 13/ 5/2023 21:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.72 24 15.04 2 1 0.00 / 882.34 3 3
2 7 2004.76 44 14.11 3038 1886 1.89 / 884.23 3 3
3 13 1610.92 22 14.20 2531 791 2.68 / 885.02 3 3
4 13 1035.84 22 14.40 1767 560 3.24 / 885.58 3 3
5 13 307.28 22 14.76 776 252 3.49 / 885.83 3 3
6 8 -0.16 165 14.93 301 741 4.23 / 886.57 3 3
Average= 4.20
(KJ/cycle)

Cycle 209 GMT 3/ 5/2023 22:19: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.44 24 15.04 1 0 0.00 / 878.09 3 3
2 7 2004.88 44 14.12 3041 1889 1.89 / 879.98 3 3
3 13 1610.16 22 14.20 2551 797 2.69 / 880.78 3 3
4 13 1048.80 22 14.40 1790 567 3.25 / 881.34 3 3
5 13 326.40 22 14.75 802 260 3.51 / 881.60 3 3
6 8 0.00 165 14.93 300 739 4.25 / 882.34 3 3
Average= 4.20
(KJ/cycle)

Cycle 208 GMT 23/ 4/2023 22:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.92 24 15.04 2 1 0.00 / 873.75 3 3
2 7 2003.20 44 14.12 3054 1897 1.90 / 875.65 3 3
3 13 1742.16 22 14.16 2732 851 2.75 / 876.50 3 3
4 13 1150.04 22 14.35 1927 608 3.36 / 877.11 3 3
5 13 273.24 22 14.79 728 237 3.59 / 877.34 3 3
6 8 -0.08 165 14.93 303 746 4.34 / 878.09 3 3
Average= 4.20
(KJ/cycle)

Cycle 207 GMT 13/ 4/2023 23:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.44 24 15.04 1 0 0.00 / 869.34 3 3
2 7 2007.64 44 14.11 3043 1889 1.89 / 871.23 3 3
3 13 1740.64 22 14.16 2725 849 2.74 / 872.08 3 3
4 13 1026.28 22 14.41 1762 559 3.30 / 872.63 3 3
5 13 303.96 22 14.77 778 253 3.55 / 872.89 3 3
6 13 36.88 22 14.94 368 121 3.67 / 873.01 3 3
7 8 -0.12 165 14.92 301 741 4.41 / 873.75 3 3
Average= 4.20
(KJ/cycle)

Cycle 206 GMT 4/ 4/2023 0: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.00 24 15.03 1 0 0.00 / 864.94 3 3
2 7 2005.08 44 14.11 3036 1885 1.89 / 866.82 3 3
3 13 1744.28 22 14.17 2711 845 2.73 / 867.67 3 3
4 13 1019.20 22 14.42 1751 555 3.29 / 868.22 3 3
5 13 301.76 22 14.77 767 249 3.54 / 868.47 3 3
6 13 32.12 22 14.94 361 119 3.65 / 868.59 3 3
7 8 -0.16 165 14.92 303 746 4.40 / 869.34 3 3
Average= 4.20
(KJ/cycle)

Cycle 205 GMT 25/ 3/2023 0:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.92 24 15.04 1 0 0.00 / 860.53 3 3
2 7 2003.80 44 14.12 3035 1886 1.89 / 862.41 3 3
3 13 1748.52 22 14.16 2728 850 2.74 / 863.26 3 3
4 13 1018.16 22 14.42 1745 554 3.29 / 863.82 3 3
5 13 301.76 22 14.77 766 249 3.54 / 864.06 3 3
6 13 32.28 22 14.94 358 118 3.66 / 864.18 3 3
7 8 -0.12 165 14.92 307 756 4.41 / 864.94 3 3
Average= 4.20
(KJ/cycle)

Cycle 204 GMT 15/ 3/2023 1:25: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.96 24 15.04 1 0 0.00 / 856.12 3 3
2 7 2010.16 44 14.11 3052 1895 1.90 / 858.01 3 3
3 13 1749.80 22 14.16 2732 851 2.75 / 858.86 3 3
4 13 1026.56 22 14.41 1761 558 3.30 / 859.42 3 3
5 13 301.56 22 14.77 767 249 3.55 / 859.67 3 3
6 13 34.40 22 14.94 365 120 3.67 / 859.79 3 3
7 8 -0.24 165 14.92 299 736 4.41 / 860.53 3 3
Average= 4.20
(KJ/cycle)

Cycle 203 GMT 5/ 3/2023 1:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.68 24 15.05 1 0 0.00 / 851.72 3 3
2 7 2006.16 44 14.12 3037 1887 1.89 / 853.61 3 3
3 13 1735.64 22 14.18 2706 844 2.73 / 854.45 3 3
4 13 1007.40 22 14.42 1727 548 3.28 / 855.00 3 3
5 13 282.88 22 14.78 749 244 3.52 / 855.24 3 3
6 13 28.12 22 14.94 352 116 3.64 / 855.36 3 3
7 8 -0.08 165 14.92 308 758 4.40 / 856.12 3 3
Average= 4.20
(KJ/cycle)

Cycle 202 GMT 23/ 2/2023 2:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 24 15.05 2 1 0.00 / 847.43 3 3
2 7 2002.68 44 14.12 3042 1890 1.89 / 849.32 3 3
3 13 1621.28 22 14.20 2554 798 2.69 / 850.12 3 3
4 13 1055.20 22 14.40 1801 571 3.26 / 850.69 3 3
5 13 325.44 22 14.75 803 261 3.52 / 850.95 3 3
6 8 -0.04 165 14.93 313 771 4.29 / 851.72 3 3
Average= 4.20
(KJ/cycle)

Cycle 201 GMT 13/ 2/2023 3: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.80 23 15.05 1 0 0.00 / 843.15 3 3
2 3 1030.84 1 15.35 3 0 0.00 / 843.15 3 3
3 7 2006.24 44 14.12 3041 1889 1.89 / 845.04 3 3
4 13 1745.68 22 14.17 2730 851 2.74 / 845.89 3 3
5 13 1018.68 22 14.42 1753 556 3.30 / 846.45 3 3
6 13 297.00 22 14.78 762 248 3.54 / 846.69 3 3
7 8 -0.16 165 14.94 298 735 4.28 / 847.43 3 3
Average= 4.20
(KJ/cycle)

Cycle 200 GMT 3/ 2/2023 3:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 23 15.04 1 0 0.00 / 838.70 3 3
2 7 2003.00 44 14.12 3040 1889 1.89 / 840.58 3 3
3 13 1728.04 22 14.18 2687 838 2.73 / 841.42 3 3
4 13 999.60 22 14.43 1725 548 3.27 / 841.97 3 3
5 13 406.44 22 14.71 919 297 3.57 / 842.27 3 3
6 13 24.28 22 14.95 348 114 3.69 / 842.38 3 3
7 8 -0.12 165 14.92 312 768 4.45 / 843.15 3 3
Average= 4.19
(KJ/cycle)

Cycle 199 GMT 24/ 1/2023 4: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.44 23 15.04 1 0 0.00 / 834.28 3 3
2 7 2011.20 44 14.12 3050 1895 1.90 / 836.17 3 3
3 13 1743.40 22 14.17 2731 851 2.75 / 837.02 3 3
4 13 1023.40 22 14.42 1756 557 3.30 / 837.58 3 3
5 13 307.16 22 14.77 781 254 3.56 / 837.83 3 3
6 13 32.52 22 14.94 364 120 3.68 / 837.95 3 3
7 8 -0.12 165 14.93 301 741 4.42 / 838.70 3 3
Average= 4.19
(KJ/cycle)

Cycle 198 GMT 14/ 1/2023 4:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.84 23 15.05 2 1 0.00 / 829.97 3 3
2 7 2007.72 44 14.12 3043 1891 1.89 / 831.86 3 3
3 13 1604.32 22 14.22 2533 792 2.68 / 832.66 3 3
4 13 1041.68 22 14.40 1786 566 3.25 / 833.22 3 3
5 13 440.68 22 14.69 960 310 3.56 / 833.53 3 3
6 8 -0.12 165 14.93 302 744 4.30 / 834.28 3 3
Average= 4.19
(KJ/cycle)

Cycle 197 GMT 4/ 1/2023 5:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.72 24 15.04 1 0 0.00 / 825.73 3 3
2 7 2010.64 44 14.12 3037 1887 1.89 / 827.62 3 3
3 13 1732.48 22 14.17 2701 842 2.73 / 828.46 3 3
4 13 876.08 22 14.49 1549 494 3.22 / 828.96 3 3
5 13 312.08 22 14.77 782 254 3.48 / 829.21 3 3
6 8 -0.04 165 14.94 309 762 4.24 / 829.97 3 3
Average= 4.19
(KJ/cycle)

Cycle 196 GMT 25/12/2022 5:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.48 23 15.05 2 1 0.00 / 821.38 3 3
2 3 1023.72 1 15.36 3 0 0.00 / 821.38 3 3
3 7 2010.52 44 14.12 3046 1892 1.89 / 823.27 3 3
4 13 1606.36 22 14.21 2542 795 2.69 / 824.07 3 3
5 13 1034.12 22 14.42 1779 564 3.25 / 824.63 3 3
6 13 306.56 22 14.77 777 252 3.50 / 824.88 3 3
7 13 15.08 22 14.95 331 109 3.61 / 824.99 3 3
8 8 -0.04 165 14.93 301 741 4.36 / 825.73 3 3
Average= 4.19
(KJ/cycle)

Cycle 195 GMT 15/12/2022 6:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.72 23 15.05 1 0 0.00 / 817.05 3 3
2 7 2010.72 44 14.12 3042 1890 1.89 / 818.94 3 3
3 13 1609.32 22 14.22 2530 791 2.68 / 819.74 3 3
4 13 928.64 22 14.47 1625 517 3.20 / 820.25 3 3
5 13 345.08 22 14.76 823 267 3.47 / 820.52 3 3
6 13 17.68 22 14.96 333 110 3.58 / 820.63 3 3
7 8 -0.04 165 14.94 304 749 4.33 / 821.38 3 3
Average= 4.19
(KJ/cycle)

Cycle 194 GMT 5/12/2022 6:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.52 23 15.05 1 0 0.00 / 812.79 3 3
2 7 2006.32 44 14.12 3039 1888 1.89 / 814.68 3 3
3 13 1608.44 22 14.21 2541 794 2.68 / 815.47 3 3
4 13 1042.96 22 14.41 1795 569 3.25 / 816.04 3 3
5 13 327.32 22 14.76 810 263 3.51 / 816.30 3 3
6 8 0.00 165 14.94 305 752 4.27 / 817.05 3 3
Average= 4.19
(KJ/cycle)

Cycle 193 GMT 25/11/2022 7:14:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.12 23 15.05 2 1 0.00 / 808.49 3 3
2 7 2009.28 44 14.12 3037 1887 1.89 / 810.38 3 3
3 13 1737.20 22 14.18 2702 843 2.73 / 811.22 3 3
4 13 1015.32 22 14.43 1740 552 3.28 / 811.77 3 3
5 13 302.16 22 14.78 763 248 3.53 / 812.02 3 3
6 8 0.04 165 14.94 311 767 4.30 / 812.79 3 3
Average= 4.19
(KJ/cycle)

Cycle 192 GMT 15/11/2022 7:43:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.72 23 15.05 1 0 0.00 / 804.26 3 3
2 7 2003.00 44 14.13 3028 1883 1.88 / 806.14 3 3
3 13 1607.88 22 14.22 2545 796 2.68 / 806.94 3 3
4 13 1028.88 22 14.42 1764 560 3.24 / 807.50 3 3
5 13 292.60 22 14.79 756 246 3.48 / 807.75 3 3
6 8 0.00 165 14.94 302 744 4.23 / 808.49 3 3
Average= 4.19
(KJ/cycle)

Cycle 191 GMT 5/11/2022 8:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.68 23 15.05 2 1 0.00 / 799.96 3 3
2 7 2010.84 44 14.13 3044 1893 1.89 / 801.85 3 3
3 13 1751.16 22 14.17 2744 855 2.75 / 802.70 3 3
4 13 1029.36 22 14.43 1770 562 3.31 / 803.26 3 3
5 13 314.52 22 14.78 787 256 3.57 / 803.52 3 3
6 8 0.04 165 14.94 300 740 4.31 / 804.26 3 3
Average= 4.19
(KJ/cycle)

Cycle 190 GMT 26/10/2022 8:50: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.04 23 15.04 2 1 0.00 / 795.64 3 3
2 7 2008.04 44 14.13 3037 1888 1.89 / 797.53 3 3
3 13 1737.44 22 14.19 2688 839 2.73 / 798.37 3 3
4 13 1145.24 22 14.38 1918 607 3.33 / 798.98 3 3
5 13 270.84 22 14.80 725 236 3.57 / 799.21 3 3
6 8 -0.04 165 14.94 300 740 4.31 / 799.95 3 3
Average= 4.19
(KJ/cycle)

Cycle 189 GMT 16/10/2022 9:22:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.12 22 15.05 2 1 0.00 / 791.29 3 3
2 7 2006.04 44 14.12 3046 1892 1.89 / 793.18 3 3
3 13 1729.04 22 14.19 2716 848 2.74 / 794.03 3 3
4 13 882.88 22 14.50 1560 498 3.24 / 794.52 3 3
5 13 329.44 22 14.77 806 262 3.50 / 794.79 3 3
6 13 17.28 22 14.96 337 111 3.61 / 794.90 3 3
7 8 0.04 165 14.93 303 746 4.36 / 795.64 3 3
Average= 4.19
(KJ/cycle)

Cycle 188 GMT 6/10/2022 9:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.36 22 15.05 1 0 0.00 / 786.96 3 3
2 7 2004.04 44 14.13 3035 1887 1.89 / 788.85 3 3
3 13 1877.88 22 14.15 2882 897 2.78 / 789.75 3 3
4 13 1003.20 22 14.45 1720 547 3.33 / 790.29 3 3
5 13 290.44 22 14.80 749 244 3.58 / 790.54 3 3
6 8 0.04 165 14.94 304 749 4.32 / 791.29 3 3
Average= 4.19
(KJ/cycle)

Cycle 187 GMT 26/ 9/2022 10:26:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.80 24 15.04 1 0 0.00 / 782.65 3 3
2 3 938.76 -1 15.36 0 0 0.00 / 782.65 3 3
3 7 2004.76 44 14.13 3027 1882 1.88 / 784.54 3 3
4 13 1738.44 22 14.18 2714 847 2.73 / 785.38 3 3
5 13 1132.16 22 14.38 1899 601 3.33 / 785.98 3 3
6 13 268.60 22 14.81 719 234 3.56 / 786.22 3 3
7 8 -0.04 165 14.94 302 744 4.31 / 786.96 3 3
Average= 4.19
(KJ/cycle)

Cycle 186 GMT 16/ 9/2022 10:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.52 23 15.05 2 1 0.00 / 778.35 3 3
2 7 2010.68 44 14.13 3039 1889 1.89 / 780.24 3 3
3 13 1741.04 22 14.19 2712 847 2.74 / 781.09 3 3
4 13 1023.44 22 14.44 1754 557 3.29 / 781.64 3 3
5 13 298.84 22 14.79 766 249 3.54 / 781.89 3 3
6 8 0.04 165 14.94 308 759 4.30 / 782.65 3 3
Average= 4.19
(KJ/cycle)

Cycle 185 GMT 6/ 9/2022 11:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.80 22 15.05 1 0 0.00 / 774.06 3 3
2 3 1044.12 1 15.36 2 0 0.00 / 774.06 3 3
3 7 2011.12 44 14.12 3055 1898 1.90 / 775.96 3 3
4 13 1619.04 22 14.23 2551 799 2.70 / 776.76 3 3
5 13 1049.84 22 14.42 1804 572 3.27 / 777.33 3 3
6 13 313.08 22 14.78 789 257 3.53 / 777.59 3 3
7 8 -0.04 165 14.94 309 762 4.29 / 778.35 3 3
Average= 4.18
(KJ/cycle)

Cycle 184 GMT 27/ 8/2022 11:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.32 22 15.04 2 1 0.00 / 769.81 3 3
2 3 1024.00 1 15.36 3 0 0.00 / 769.81 3 3
3 7 2006.52 44 14.13 3039 1889 1.89 / 771.70 3 3
4 13 1605.84 22 14.23 2535 794 2.68 / 772.49 3 3
5 13 1026.96 22 14.43 1756 557 3.24 / 773.05 3 3
6 13 302.84 22 14.79 776 252 3.49 / 773.30 3 3
7 8 -0.04 165 14.94 308 759 4.25 / 774.06 3 3
Average= 4.18
(KJ/cycle)

Cycle 183 GMT 17/ 8/2022 12:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 23 15.05 2 1 0.00 / 765.48 3 3
2 3 962.32 -1 15.36 0 0 0.00 / 765.48 3 3
3 7 2010.20 44 14.13 3039 1889 1.89 / 767.37 3 3
4 13 1614.72 22 14.23 2553 799 2.69 / 768.17 3 3
5 13 909.48 22 14.49 1606 512 3.20 / 768.68 3 3
6 13 326.96 22 14.77 802 261 3.46 / 768.94 3 3
7 13 35.12 22 14.96 362 119 3.58 / 769.06 3 3
8 8 0.00 165 14.94 305 752 4.33 / 769.81 3 3
Average= 4.18
(KJ/cycle)

Cycle 182 GMT 7/ 8/2022 13: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.56 22 15.06 1 0 0.00 / 761.19 3 3
2 3 1047.84 1 15.36 2 0 0.00 / 761.19 3 3
3 7 2006.00 44 14.13 3041 1891 1.89 / 763.09 3 3
4 13 1731.40 22 14.19 2702 844 2.73 / 763.93 3 3
5 13 1008.84 22 14.44 1744 554 3.29 / 764.48 3 3
6 13 289.52 22 14.81 750 244 3.53 / 764.73 3 3
7 8 0.04 165 14.95 304 750 4.28 / 765.48 3 3
Average= 4.18
(KJ/cycle)

Cycle 181 GMT 28/ 7/2022 13:39: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.80 23 15.05 1 0 0.00 / 756.92 3 3
2 3 969.00 -1 15.36 0 0 0.00 / 756.92 3 3
3 7 2006.88 44 14.13 3046 1894 1.89 / 758.81 3 3
4 13 1611.84 22 14.23 2547 797 2.69 / 759.61 3 3
5 13 1050.76 22 14.42 1801 571 3.26 / 760.18 3 3
6 13 329.28 22 14.77 808 263 3.53 / 760.44 3 3
7 8 0.16 165 14.95 304 750 4.28 / 761.19 3 3
Average= 4.18
(KJ/cycle)

Cycle 180 GMT 18/ 7/2022 14:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.88 23 15.06 1 0 0.00 / 752.44 3 3
2 7 2003.92 44 14.13 3035 1887 1.89 / 754.33 3 3
3 13 1742.12 22 14.19 2711 846 2.73 / 755.18 3 3
4 13 1010.28 22 14.44 1741 553 3.29 / 755.73 3 3
5 13 426.72 22 14.72 947 307 3.59 / 756.04 3 3
6 13 63.60 22 14.95 404 133 3.73 / 756.17 3 3
7 8 0.04 165 14.95 304 750 4.48 / 756.92 3 3
Average= 4.18
(KJ/cycle)

Cycle 179 GMT 8/ 7/2022 14:37:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.48 23 15.06 1 0 0.00 / 748.19 3 3
2 7 2008.88 44 14.13 3039 1889 1.89 / 750.08 3 3
3 13 1604.44 22 14.23 2549 798 2.69 / 750.88 3 3
4 13 1029.76 22 14.44 1760 559 3.25 / 751.44 3 3
5 13 301.64 22 14.79 769 250 3.50 / 751.69 3 3
6 8 -0.20 165 14.95 305 752 4.25 / 752.44 3 3
Average= 4.18
(KJ/cycle)

Cycle 178 GMT 28/ 6/2022 15: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.24 23 15.06 1 0 0.00 / 743.91 3 3
2 7 2007.84 44 14.13 3035 1887 1.89 / 745.79 3 3
3 13 1742.92 22 14.20 2713 848 2.73 / 746.64 3 3
4 13 1011.84 22 14.45 1738 553 3.29 / 747.19 3 3
5 13 290.20 22 14.80 756 246 3.53 / 747.44 3 3
6 8 0.16 165 14.96 306 755 4.29 / 748.19 3 3
Average= 4.18
(KJ/cycle)

Cycle 177 GMT 18/ 6/2022 15:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.24 23 15.06 1 0 0.00 / 739.61 3 3
2 7 2004.72 44 14.14 3038 1890 1.89 / 741.50 3 3
3 13 1739.32 22 14.20 2720 850 2.74 / 742.35 3 3
4 13 1016.36 22 14.44 1750 556 3.30 / 742.91 3 3
5 13 304.64 22 14.80 770 251 3.55 / 743.16 3 3
6 8 0.00 165 14.95 302 745 4.29 / 743.91 3 3
Average= 4.18
(KJ/cycle)

Cycle 176 GMT 8/ 6/2022 16: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.08 24 15.07 2 1 0.00 / 735.38 3 3
2 7 2005.28 44 14.13 3038 1889 1.89 / 737.27 3 3
3 13 1598.00 22 14.25 2524 791 2.68 / 738.06 3 3
4 13 1033.68 22 14.43 1775 563 3.24 / 738.63 3 3
5 13 301.36 22 14.80 767 250 3.49 / 738.88 3 3
6 8 0.08 165 14.96 298 736 4.23 / 739.61 3 3
Average= 4.18
(KJ/cycle)

Cycle 175 GMT 29/ 5/2022 16:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.52 24 15.07 1 0 0.00 / 731.12 3 3
2 7 2009.12 44 14.14 3042 1893 1.89 / 733.01 3 3
3 13 1613.84 22 14.24 2549 799 2.69 / 733.81 3 3
4 13 1045.32 22 14.44 1782 566 3.26 / 734.38 3 3
5 13 318.20 22 14.79 802 261 3.52 / 734.64 3 3
6 8 0.00 165 14.97 301 743 4.26 / 735.38 3 3
Average= 4.18
(KJ/cycle)

Cycle 174 GMT 19/ 5/2022 16:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.44 24 15.07 2 1 0.00 / 726.87 3 3
2 7 2004.04 44 14.14 3036 1889 1.89 / 728.76 3 3
3 13 1727.80 22 14.21 2686 840 2.73 / 729.60 3 3
4 13 1004.12 22 14.46 1722 548 3.28 / 730.15 3 3
5 13 291.56 22 14.81 749 244 3.52 / 730.39 3 3
6 8 0.04 165 14.97 296 731 4.25 / 731.12 3 3
Average= 4.18
(KJ/cycle)

Cycle 173 GMT 9/ 5/2022 17:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.24 24 15.08 1 0 0.00 / 722.65 3 3
2 7 2006.00 44 14.14 3035 1888 1.89 / 724.54 3 3
3 13 1600.96 22 14.25 2521 790 2.68 / 725.33 3 3
4 13 1028.04 22 14.44 1772 563 3.24 / 725.89 3 3
5 13 296.64 22 14.81 758 247 3.49 / 726.14 3 3
6 8 0.04 165 14.97 297 734 4.22 / 726.87 3 3
Average= 4.18
(KJ/cycle)

Cycle 172 GMT 29/ 4/2022 17:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 24 15.07 1 0 0.00 / 718.34 3 3
2 7 2007.36 44 14.14 3037 1889 1.89 / 720.23 3 3
3 13 1728.64 22 14.21 2698 843 2.73 / 721.07 3 3
4 13 1004.88 22 14.46 1729 550 3.28 / 721.62 3 3
5 13 408.64 22 14.74 924 300 3.58 / 721.92 3 3
6 8 0.08 165 14.97 293 724 4.31 / 722.65 3 3
Average= 4.18
(KJ/cycle)

Cycle 171 GMT 19/ 4/2022 18:40: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.40 23 15.07 1 0 0.00 / 714.14 3 3
2 7 2002.88 44 14.13 3040 1890 1.89 / 716.03 3 3
3 13 1606.12 22 14.24 2547 798 2.69 / 716.83 3 3
4 13 898.20 22 14.51 1586 506 3.19 / 717.34 3 3
5 13 320.60 22 14.80 795 259 3.45 / 717.60 3 3
6 8 0.00 165 14.97 301 743 4.20 / 718.34 3 3
Average= 4.18
(KJ/cycle)

Cycle 170 GMT 9/ 4/2022 19:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.28 24 15.08 1 0 0.00 / 709.88 3 3
2 3 968.72 -1 15.38 0 0 0.00 / 709.88 3 3
3 7 2007.24 44 14.14 3042 1893 1.89 / 711.77 3 3
4 13 1617.40 22 14.24 2552 799 2.69 / 712.57 3 3
5 13 1044.28 22 14.44 1800 572 3.26 / 713.14 3 3
6 13 310.56 22 14.80 783 255 3.52 / 713.40 3 3
7 8 0.04 165 14.97 301 743 4.26 / 714.14 3 3
Average= 4.18
(KJ/cycle)

Cycle 169 GMT 30/ 3/2022 19:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.92 24 15.07 1 0 0.00 / 705.53 3 3
2 3 1030.48 1 15.38 3 0 0.00 / 705.53 3 3
3 7 2008.12 44 14.14 3044 1894 1.89 / 707.43 3 3
4 13 1736.40 22 14.21 2723 851 2.75 / 708.28 3 3
5 13 1015.44 22 14.45 1755 558 3.30 / 708.83 3 3
6 13 424.56 22 14.73 940 305 3.61 / 709.14 3 3
7 8 0.08 165 14.97 300 741 4.35 / 709.88 3 3
Average= 4.18
(KJ/cycle)

Cycle 168 GMT 20/ 3/2022 20:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.72 23 15.08 1 0 0.00 / 701.32 3 3
2 7 2005.44 44 14.14 3050 1898 1.90 / 703.22 3 3
3 13 1605.76 22 14.25 2531 793 2.69 / 704.01 3 3
4 13 900.56 22 14.51 1594 509 3.20 / 704.52 3 3
5 13 328.72 22 14.79 811 264 3.46 / 704.79 3 3
6 8 0.04 165 14.96 302 745 4.21 / 705.53 3 3
Average= 4.17
(KJ/cycle)

Cycle 167 GMT 10/ 3/2022 20:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.92 23 15.07 1 0 0.00 / 697.04 3 3
2 7 2004.28 45 14.14 3045 1938 1.94 / 698.98 3 3
3 13 1726.68 22 14.21 2712 848 2.79 / 699.82 3 3
4 13 873.48 22 14.52 1560 498 3.28 / 700.32 3 3
5 13 309.20 22 14.81 784 255 3.54 / 700.58 3 3
6 8 0.04 165 14.97 301 743 4.28 / 701.32 3 3
Average= 4.17
(KJ/cycle)

Cycle 166 GMT 28/ 2/2022 21:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.28 24 15.08 1 0 0.00 / 692.81 3 3
2 3 970.56 -1 15.38 0 0 0.00 / 692.81 3 3
3 7 2004.48 44 14.14 3044 1894 1.89 / 694.70 3 3
4 13 1595.52 22 14.25 2523 791 2.69 / 695.49 3 3
5 13 1026.00 22 14.44 1763 560 3.25 / 696.05 3 3
6 13 288.76 22 14.82 752 245 3.49 / 696.30 3 3
7 8 0.08 165 14.97 301 743 4.23 / 697.04 3 3
Average= 4.17
(KJ/cycle)

Cycle 165 GMT 18/ 2/2022 22: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.56 23 15.08 1 0 0.00 / 688.52 3 3
2 3 1035.28 1 15.38 3 0 0.00 / 688.52 3 3
3 7 2008.32 44 14.14 3042 1893 1.89 / 690.41 3 3
4 13 1732.32 22 14.22 2696 843 2.74 / 691.26 3 3
5 13 1005.00 22 14.47 1722 548 3.28 / 691.81 3 3
6 13 293.44 22 14.82 763 249 3.53 / 692.05 3 3
7 8 0.04 165 14.97 304 751 4.28 / 692.80 3 3
Average= 4.17
(KJ/cycle)

Cycle 164 GMT 8/ 2/2022 22:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.84 23 15.07 1 0 0.00 / 684.32 3 3
2 7 2004.56 44 14.12 3037 1887 1.89 / 686.21 3 3
3 13 1605.52 22 14.26 2537 796 2.68 / 687.00 3 3
4 13 911.96 22 14.50 1600 510 3.19 / 687.51 3 3
5 13 336.04 22 14.79 816 266 3.46 / 687.78 3 3
6 8 0.04 165 14.97 300 741 4.20 / 688.52 3 3
Average= 4.17
(KJ/cycle)

Cycle 163 GMT 29/ 1/2022 22:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.36 23 15.07 2 1 0.00 / 680.07 3 3
2 7 2003.76 44 14.14 3036 1889 1.89 / 681.96 3 3
3 13 1601.20 22 14.25 2536 795 2.68 / 682.75 3 3
4 13 1021.64 22 14.45 1757 559 3.24 / 683.31 3 3
5 13 299.12 22 14.81 767 250 3.49 / 683.56 3 3
6 8 0.00 165 14.97 308 761 4.25 / 684.32 3 3
Average= 4.17
(KJ/cycle)

Cycle 162 GMT 19/ 1/2022 23:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.04 23 15.07 1 0 0.00 / 675.85 3 3
2 7 2004.76 44 14.15 3031 1887 1.89 / 677.74 3 3
3 13 1605.84 22 14.26 2522 791 2.68 / 678.53 3 3
4 13 911.36 22 14.51 1603 512 3.19 / 679.04 3 3
5 13 329.20 22 14.79 811 264 3.45 / 679.30 3 3
6 8 0.08 165 14.97 309 763 4.22 / 680.07 3 3
Average= 4.17
(KJ/cycle)

Cycle 161 GMT 9/ 1/2022 23:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.92 23 15.08 1 0 0.00 / 671.46 3 3
2 7 2005.00 44 14.15 3041 1893 1.89 / 673.36 3 3
3 13 1602.88 22 14.27 2524 792 2.69 / 674.15 3 3
4 13 1029.00 22 14.45 1768 562 3.25 / 674.71 3 3
5 13 295.36 22 14.81 762 248 3.50 / 674.96 3 3
6 13 14.28 22 14.99 330 109 3.61 / 675.07 3 3
7 8 -0.04 165 14.96 316 780 4.39 / 675.85 3 3
Average= 4.17
(KJ/cycle)

Cycle 160 GMT 31/12/2021 0:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.92 23 15.08 2 1 0.00 / 667.20 3 3
2 7 2004.84 44 14.15 3025 1883 1.88 / 669.09 3 3
3 13 1735.76 22 14.22 2702 845 2.73 / 669.93 3 3
4 13 997.20 22 14.47 1719 547 3.28 / 670.48 3 3
5 13 281.64 22 14.83 738 241 3.52 / 670.72 3 3
6 8 0.08 165 14.98 301 744 4.26 / 671.46 3 3
Average= 4.17
(KJ/cycle)

Cycle 159 GMT 21/12/2021 0:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.20 23 15.08 2 1 0.00 / 662.91 3 3
2 7 2003.92 44 14.15 3035 1890 1.89 / 664.80 3 3
3 13 1727.88 22 14.23 2688 842 2.73 / 665.64 3 3
4 13 1006.24 22 14.47 1733 552 3.28 / 666.19 3 3
5 13 290.00 22 14.83 747 244 3.53 / 666.44 3 3
6 8 0.00 165 14.98 310 766 4.29 / 667.20 3 3
Average= 4.17
(KJ/cycle)

Cycle 158 GMT 11/12/2021 1:14:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.32 23 15.08 2 1 0.00 / 658.60 3 3
2 7 2008.40 44 14.15 3031 1887 1.89 / 660.48 3 3
3 13 1728.60 22 14.22 2706 847 2.73 / 661.33 3 3
4 13 1001.24 22 14.48 1727 550 3.28 / 661.88 3 3
5 13 299.24 22 14.82 767 250 3.53 / 662.13 3 3
6 8 0.20 165 14.97 315 778 4.31 / 662.91 3 3
Average= 4.17
(KJ/cycle)

Cycle 157 GMT 1/12/2021 1:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.28 23 15.09 2 1 0.00 / 654.39 3 3
2 7 2007.28 44 14.16 3024 1884 1.88 / 656.28 3 3
3 13 1599.56 22 14.27 2532 795 2.68 / 657.07 3 3
4 13 883.48 22 14.53 1555 497 3.18 / 657.57 3 3
5 13 310.52 22 14.82 767 250 3.43 / 657.82 3 3
6 8 0.04 165 14.98 315 779 4.21 / 658.60 3 3
Average= 4.17
(KJ/cycle)

Cycle 156 GMT 21/11/2021 2: 6: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.72 22 15.09 2 1 0.00 / 650.14 3 3
2 7 2009.76 44 14.15 3038 1891 1.89 / 652.03 3 3
3 13 1746.56 22 14.23 2708 848 2.74 / 652.88 3 3
4 13 1003.68 22 14.48 1721 548 3.29 / 653.43 3 3
5 13 284.32 22 14.84 731 239 3.53 / 653.67 3 3
6 8 0.08 165 14.99 292 722 4.25 / 654.39 3 3
Average= 4.17
(KJ/cycle)

Cycle 155 GMT 11/11/2021 2:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.52 22 15.08 1 0 0.00 / 645.91 3 3
2 7 2003.80 44 14.15 3022 1881 1.88 / 647.79 3 3
3 13 1736.52 22 14.23 2684 840 2.72 / 648.63 3 3
4 13 1000.16 22 14.48 1719 548 3.27 / 649.18 3 3
5 13 278.40 22 14.84 730 238 3.51 / 649.42 3 3
6 8 0.04 165 14.99 294 727 4.24 / 650.14 3 3
Average= 4.17
(KJ/cycle)

Cycle 154 GMT 1/11/2021 3: 6: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.68 22 15.09 2 1 0.00 / 641.73 3 3
2 7 2008.96 44 14.16 3036 1892 1.89 / 643.62 3 3
3 13 1602.00 22 14.28 2529 795 2.69 / 644.42 3 3
4 13 901.72 22 14.53 1579 505 3.19 / 644.92 3 3
5 13 320.72 22 14.82 786 256 3.45 / 645.18 3 3
6 8 0.00 165 14.98 294 727 4.17 / 645.91 3 3
Average= 4.17
(KJ/cycle)

Cycle 153 GMT 22/10/2021 3:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.92 22 15.09 2 1 0.00 / 637.53 3 3
2 7 2012.56 44 14.15 3043 1895 1.90 / 639.43 3 3
3 13 1618.64 22 14.27 2539 797 2.69 / 640.22 3 3
4 13 917.72 22 14.52 1609 514 3.21 / 640.74 3 3
5 13 336.00 22 14.81 812 265 3.47 / 641.00 3 3
6 8 0.12 165 14.98 296 732 4.20 / 641.73 3 3
Average= 4.17
(KJ/cycle)

Cycle 152 GMT 12/10/2021 3:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.64 22 15.09 2 1 0.00 / 633.27 3 3
2 7 2005.08 44 14.15 3029 1886 1.89 / 635.16 3 3
3 13 1738.16 22 14.22 2705 846 2.73 / 636.00 3 3
4 13 998.92 22 14.49 1720 548 3.28 / 636.55 3 3
5 13 292.76 22 14.84 747 244 3.52 / 636.80 3 3
6 8 0.04 165 14.99 297 735 4.26 / 637.53 3 3
Average= 4.17
(KJ/cycle)

Cycle 151 GMT 2/10/2021 4:17: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.96 23 15.09 2 1 0.00 / 628.96 3 3
2 3 970.40 -1 15.39 0 0 0.00 / 628.96 3 3
3 7 2003.84 44 14.16 3029 1887 1.89 / 630.85 3 3
4 13 1728.80 22 14.24 2706 848 2.74 / 631.69 3 3
5 13 1138.84 22 14.42 1911 606 3.34 / 632.30 3 3
6 13 261.28 22 14.86 702 229 3.57 / 632.53 3 3
7 8 0.08 165 14.98 300 742 4.31 / 633.27 3 3
Average= 4.17
(KJ/cycle)

Cycle 150 GMT 22/ 9/2021 4:48:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.20 23 15.10 2 1 0.00 / 624.70 3 3
2 7 2003.68 44 14.16 3026 1885 1.89 / 626.59 3 3
3 13 1733.68 22 14.24 2695 844 2.73 / 627.43 3 3
4 13 999.20 22 14.49 1720 548 3.28 / 627.98 3 3
5 13 283.12 22 14.84 742 242 3.52 / 628.22 3 3
6 8 0.08 165 14.99 298 737 4.26 / 628.96 3 3
Average= 4.17
(KJ/cycle)

Cycle 149 GMT 12/ 9/2021 5:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.16 23 15.10 2 1 0.00 / 620.45 3 3
2 3 1022.40 1 15.39 3 0 0.00 / 620.45 3 3
3 7 2007.20 44 14.16 3026 1885 1.89 / 622.34 3 3
4 13 1731.72 22 14.24 2677 839 2.72 / 623.18 3 3
5 13 1015.68 22 14.48 1731 551 3.28 / 623.73 3 3
6 13 285.68 22 14.84 735 240 3.52 / 623.97 3 3
7 8 0.24 165 14.99 296 732 4.25 / 624.70 3 3
Average= 4.16
(KJ/cycle)

Cycle 148 GMT 2/ 9/2021 5:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.88 22 15.09 1 0 0.00 / 616.16 3 3
2 3 1025.60 1 15.39 3 0 0.00 / 616.16 3 3
3 7 2004.96 44 14.16 3033 1890 1.89 / 618.05 3 3
4 13 1730.76 22 14.24 2703 847 2.74 / 618.89 3 3
5 13 1124.28 22 14.43 1893 601 3.34 / 619.49 3 3
6 13 243.96 22 14.88 679 222 3.56 / 619.72 3 3
7 8 -0.12 165 14.99 297 735 4.29 / 620.45 3 3
Average= 4.16
(KJ/cycle)

Cycle 147 GMT 23/ 8/2021 6:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 23 15.08 2 1 0.00 / 611.70 3 3
2 3 969.84 -1 15.39 0 0 0.00 / 611.70 3 3
3 7 2006.68 44 14.16 3035 1891 1.89 / 613.59 3 3
4 13 1738.68 22 14.24 2711 849 2.74 / 614.44 3 3
5 13 1006.24 22 14.49 1723 549 3.29 / 614.99 3 3
6 13 413.00 22 14.76 923 300 3.59 / 615.29 3 3
7 13 56.12 22 14.98 383 126 3.72 / 615.42 3 3
8 8 0.08 165 14.98 300 742 4.46 / 616.16 3 3
Average= 4.16
(KJ/cycle)

Cycle 146 GMT 13/ 8/2021 6:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.32 23 15.10 1 0 0.00 / 607.24 3 3
2 3 1038.32 1 15.39 2 0 0.00 / 607.24 3 3
3 7 2004.32 44 14.17 3035 1892 1.89 / 609.13 3 3
4 13 1725.64 22 14.25 2691 844 2.74 / 609.98 3 3
5 13 1125.60 22 14.43 1880 597 3.33 / 610.57 3 3
6 13 360.88 22 14.79 851 277 3.61 / 610.85 3 3
7 13 18.92 22 15.01 327 108 3.72 / 610.96 3 3
8 8 -0.04 165 14.98 300 742 4.46 / 611.70 3 3
Average= 4.16
(KJ/cycle)

Cycle 145 GMT 3/ 8/2021 7: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.68 22 15.09 1 0 0.00 / 603.01 3 3
2 7 2003.28 44 14.16 3033 1890 1.89 / 604.90 3 3
3 13 1600.24 22 14.28 2525 793 2.68 / 605.69 3 3
4 13 1028.04 22 14.48 1756 559 3.24 / 606.25 3 3
5 13 297.44 22 14.84 760 248 3.49 / 606.50 3 3
6 8 0.08 165 14.99 299 740 4.23 / 607.24 3 3
Average= 4.16
(KJ/cycle)

Cycle 144 GMT 24/ 7/2021 7:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.76 23 15.09 2 1 0.00 / 598.76 3 3
2 7 2009.12 44 14.16 3040 1894 1.89 / 600.66 3 3
3 13 1611.48 22 14.28 2538 797 2.69 / 601.45 3 3
4 13 1029.16 22 14.47 1766 562 3.25 / 602.02 3 3
5 13 289.80 22 14.84 754 246 3.50 / 602.26 3 3
6 8 0.04 165 14.99 302 747 4.25 / 603.01 3 3
Average= 4.16
(KJ/cycle)

Cycle 143 GMT 14/ 7/2021 8: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.04 23 15.09 1 0 0.00 / 594.55 3 3
2 7 2003.16 44 14.17 3032 1890 1.89 / 596.44 3 3
3 13 1596.88 22 14.30 2508 789 2.68 / 597.23 3 3
4 13 1016.80 22 14.49 1739 554 3.23 / 597.79 3 3
5 13 275.68 22 14.85 727 238 3.47 / 598.03 3 3
6 8 0.20 165 14.99 298 737 4.21 / 598.76 3 3
Average= 4.16
(KJ/cycle)

Cycle 142 GMT 4/ 7/2021 8:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.32 23 15.09 2 1 0.00 / 590.16 3 3
2 7 2004.16 44 14.17 3031 1890 1.89 / 592.05 3 3
3 13 1604.72 22 14.29 2540 799 2.69 / 592.84 3 3
4 13 1169.40 22 14.41 1952 619 3.31 / 593.46 3 3
5 13 273.00 22 14.85 723 236 3.54 / 593.70 3 3
6 13 27.28 22 15.01 348 115 3.66 / 593.81 3 3
7 8 -0.16 165 14.98 299 739 4.40 / 594.55 3 3
Average= 4.16
(KJ/cycle)

Cycle 141 GMT 24/ 6/2021 8:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.40 23 15.10 2 1 0.00 / 585.78 3 3
2 7 2003.20 44 14.17 3035 1892 1.89 / 587.67 3 3
3 13 1735.96 22 14.25 2697 846 2.74 / 588.51 3 3
4 13 1004.56 22 14.49 1737 554 3.29 / 589.07 3 3
5 13 279.16 22 14.85 732 239 3.53 / 589.31 3 3
6 13 29.60 22 15.01 349 115 3.65 / 589.42 3 3
7 8 0.04 165 14.99 297 735 4.38 / 590.16 3 3
Average= 4.16
(KJ/cycle)

Cycle 140 GMT 14/ 6/2021 9:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.68 23 15.10 2 1 0.00 / 581.43 3 3
2 7 2004.72 44 14.17 3034 1892 1.89 / 583.32 3 3
3 13 1610.48 22 14.30 2523 794 2.69 / 584.11 3 3
4 13 1028.28 22 14.48 1757 560 3.25 / 584.67 3 3
5 13 299.56 22 14.84 759 248 3.49 / 584.92 3 3
6 13 33.32 22 15.01 351 116 3.61 / 585.04 3 3
7 8 0.16 165 14.99 298 737 4.35 / 585.77 3 3
Average= 4.15
(KJ/cycle)

Cycle 139 GMT 4/ 6/2021 9:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.20 23 15.10 1 0 0.00 / 577.22 3 3
2 7 2002.84 44 14.18 3025 1887 1.89 / 579.11 3 3
3 13 1595.04 22 14.30 2506 788 2.68 / 579.90 3 3
4 13 1023.92 22 14.49 1749 558 3.23 / 580.45 3 3
5 13 283.64 22 14.85 737 241 3.47 / 580.70 3 3
6 8 0.04 165 15.00 296 733 4.21 / 581.43 3 3
Average= 4.15
(KJ/cycle)

Cycle 138 GMT 25/ 5/2021 10:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.72 23 15.10 1 0 0.00 / 572.96 3 3
2 7 2006.68 44 14.17 3035 1892 1.89 / 574.85 3 3
3 13 1740.56 22 14.25 2722 853 2.75 / 575.70 3 3
4 13 1018.16 22 14.49 1739 554 3.30 / 576.26 3 3
5 13 284.76 22 14.86 734 240 3.54 / 576.50 3 3
6 8 0.20 165 15.00 292 723 4.26 / 577.22 3 3
Average= 4.15
(KJ/cycle)

Cycle 137 GMT 15/ 5/2021 10:41: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.32 23 15.10 1 0 0.00 / 568.79 3 3
2 7 2004.00 44 14.17 3026 1887 1.89 / 570.67 3 3
3 13 1592.24 22 14.31 2507 789 2.68 / 571.46 3 3
4 13 905.88 22 14.55 1581 506 3.18 / 571.97 3 3
5 13 322.52 22 14.83 798 260 3.44 / 572.23 3 3
6 8 0.12 165 15.00 295 730 4.17 / 572.96 3 3
Average= 4.15
(KJ/cycle)

Cycle 136 GMT 5/ 5/2021 11:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.12 23 15.11 1 0 0.00 / 564.54 3 3
2 7 2004.76 45 14.17 3031 1933 1.93 / 566.47 3 3
3 13 1729.84 22 14.26 2701 847 2.78 / 567.32 3 3
4 13 869.92 22 14.57 1535 492 3.27 / 567.81 3 3
5 13 304.56 22 14.84 765 250 3.52 / 568.06 3 3
6 8 0.16 165 15.00 293 725 4.25 / 568.79 3 3
Average= 4.15
(KJ/cycle)

Cycle 135 GMT 25/ 4/2021 11:41: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.08 23 15.10 1 0 0.00 / 560.29 3 3
2 7 2002.72 44 14.17 3034 1892 1.89 / 562.19 3 3
3 13 1730.68 22 14.26 2684 842 2.73 / 563.03 3 3
4 13 998.88 22 14.50 1715 547 3.28 / 563.58 3 3
5 13 274.28 22 14.87 716 234 3.52 / 563.81 3 3
6 8 0.12 165 15.01 294 728 4.24 / 564.54 3 3
Average= 4.15
(KJ/cycle)

Cycle 134 GMT 15/ 4/2021 12: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.60 24 15.11 1 0 0.00 / 555.94 3 3
2 7 2003.64 44 14.18 3030 1890 1.89 / 557.83 3 3
3 13 1733.36 22 14.26 2685 842 2.73 / 558.67 3 3
4 13 996.44 22 14.51 1701 543 3.28 / 559.22 3 3
5 13 282.00 22 14.86 736 241 3.52 / 559.46 3 3
6 13 27.84 22 15.02 336 111 3.63 / 559.57 3 3
7 8 0.16 165 15.00 293 725 4.35 / 560.29 3 3
Average= 4.15
(KJ/cycle)

Cycle 133 GMT 5/ 4/2021 12:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.60 23 15.11 1 0 0.00 / 551.73 3 3
2 7 2005.36 44 14.17 3029 1889 1.89 / 553.62 3 3
3 13 1731.76 22 14.26 2697 846 2.73 / 554.47 3 3
4 13 988.20 22 14.52 1691 540 3.28 / 555.01 3 3
5 13 268.72 22 14.88 704 230 3.51 / 555.24 3 3
6 8 -0.12 165 15.01 284 703 4.21 / 555.94 3 3
Average= 4.15
(KJ/cycle)

Cycle 132 GMT 26/ 3/2021 13: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.84 23 15.11 2 1 0.00 / 547.59 3 3
2 7 2008.32 44 14.18 3032 1892 1.89 / 549.49 3 3
3 13 1600.52 22 14.30 2517 792 2.68 / 550.28 3 3
4 13 883.92 22 14.57 1549 497 3.18 / 550.77 3 3
5 13 292.64 22 14.86 741 242 3.42 / 551.02 3 3
6 8 0.00 165 15.01 289 716 4.14 / 551.73 3 3
Average= 4.15
(KJ/cycle)

Cycle 131 GMT 16/ 3/2021 13:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.96 23 15.10 1 0 0.00 / 543.25 3 3
2 7 2003.04 44 14.18 3023 1886 1.89 / 545.14 3 3
3 13 1734.04 22 14.27 2692 845 2.73 / 545.98 3 3
4 13 1002.76 22 14.51 1713 547 3.28 / 546.53 3 3
5 13 280.60 22 14.87 723 237 3.51 / 546.76 3 3
6 13 25.08 22 15.03 332 110 3.62 / 546.87 3 3
7 8 0.00 165 15.00 291 720 4.34 / 547.59 3 3
Average= 4.15
(KJ/cycle)

Cycle 130 GMT 6/ 3/2021 13:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.24 23 15.11 2 1 0.00 / 538.99 3 3
2 7 2003.68 44 14.18 3030 1890 1.89 / 540.88 3 3
3 13 1595.00 22 14.31 2511 791 2.68 / 541.68 3 3
4 13 882.12 22 14.57 1548 496 3.18 / 542.17 3 3
5 13 302.28 22 14.86 756 247 3.43 / 542.42 3 3
6 13 26.48 22 15.02 332 110 3.53 / 542.53 3 3
7 8 -0.04 165 15.00 291 720 4.25 / 543.25 3 3
Average= 4.15
(KJ/cycle)

Cycle 129 GMT 24/ 2/2021 14:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.24 24 15.11 1 0 0.00 / 534.81 3 3
2 7 2007.64 44 14.17 3031 1890 1.89 / 536.70 3 3
3 13 1730.76 22 14.27 2684 843 2.73 / 537.54 3 3
4 13 874.20 22 14.58 1536 493 3.23 / 538.03 3 3
5 13 294.56 22 14.86 747 244 3.47 / 538.28 3 3
6 8 0.04 165 15.01 289 716 4.19 / 538.99 3 3
Average= 4.15
(KJ/cycle)

Cycle 128 GMT 14/ 2/2021 14:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.08 23 15.12 1 0 0.00 / 530.59 3 3
2 3 1026.12 1 15.41 2 0 0.00 / 530.59 3 3
3 7 2010.36 45 14.18 3037 1938 1.94 / 532.53 3 3
4 13 1608.76 22 14.31 2531 797 2.74 / 533.32 3 3
5 13 905.24 22 14.56 1582 507 3.24 / 533.83 3 3
6 13 314.00 22 14.85 776 254 3.50 / 534.09 3 3
7 8 -0.04 165 15.01 292 723 4.22 / 534.81 3 3
Average= 4.15
(KJ/cycle)

Cycle 127 GMT 4/ 2/2021 15:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.92 23 15.11 1 0 0.00 / 526.37 3 3
2 7 2002.04 44 14.18 3028 1889 1.89 / 528.25 3 3
3 13 1725.64 22 14.27 2688 844 2.73 / 529.10 3 3
4 13 993.88 22 14.52 1703 544 3.28 / 529.64 3 3
5 13 267.76 22 14.88 706 231 3.51 / 529.87 3 3
6 8 0.08 165 15.02 289 716 4.22 / 530.59 3 3
Average= 4.15
(KJ/cycle)

Cycle 126 GMT 25/ 1/2021 15:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.08 23 15.11 1 0 0.00 / 522.18 3 3
2 7 2004.04 44 14.18 3032 1892 1.89 / 524.07 3 3
3 13 1593.24 22 14.32 2501 788 2.68 / 524.86 3 3
4 13 1001.04 22 14.51 1714 547 3.23 / 525.40 3 3
5 13 275.52 22 14.87 721 236 3.46 / 525.64 3 3
6 8 0.04 165 15.01 293 726 4.19 / 526.36 3 3
Average= 4.14
(KJ/cycle)

Cycle 125 GMT 15/ 1/2021 16:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 22 15.11 1 0 0.00 / 518.00 3 3
2 7 2002.52 44 14.18 3024 1887 1.89 / 519.89 3 3
3 13 1725.88 22 14.27 2679 841 2.73 / 520.73 3 3
4 13 855.52 22 14.58 1518 487 3.22 / 521.22 3 3
5 13 276.72 22 14.87 723 237 3.45 / 521.45 3 3
6 8 0.08 165 15.02 292 724 4.18 / 522.18 3 3
Average= 4.14
(KJ/cycle)

Cycle 124 GMT 5/ 1/2021 16:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.56 22 15.12 1 0 0.00 / 513.84 3 3
2 7 2004.60 44 14.18 3029 1890 1.89 / 515.73 3 3
3 13 1606.28 22 14.31 2525 795 2.69 / 516.53 3 3
4 13 894.16 22 14.57 1563 501 3.19 / 517.03 3 3
5 13 304.72 22 14.85 764 250 3.44 / 517.28 3 3
6 8 0.08 165 15.01 291 721 4.16 / 518.00 3 3
Average= 4.14
(KJ/cycle)

Cycle 123 GMT 26/12/2020 17: 6: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.12 23 15.12 1 0 0.00 / 509.75 3 3
2 3 969.92 -1 15.41 0 0 0.00 / 509.75 3 3
3 7 2005.12 44 14.18 3035 1894 1.89 / 511.64 3 3
4 13 1587.96 22 14.32 2506 789 2.68 / 512.43 3 3
5 13 890.00 22 14.57 1556 499 3.18 / 512.93 3 3
6 13 187.04 22 14.94 582 191 3.37 / 513.12 3 3
7 8 0.04 165 15.02 291 721 4.09 / 513.84 3 3
Average= 4.14
(KJ/cycle)

Cycle 122 GMT 16/12/2020 17:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.08 22 15.12 2 1 0.00 / 505.54 3 3
2 3 1039.88 1 15.41 2 0 0.00 / 505.54 3 3
3 7 2002.88 44 14.19 3029 1891 1.89 / 507.43 3 3
4 13 1723.88 22 14.28 2679 842 2.73 / 508.27 3 3
5 13 981.76 22 14.53 1686 539 3.27 / 508.81 3 3
6 13 246.88 22 14.90 677 222 3.49 / 509.03 3 3
7 8 0.16 165 15.02 290 719 4.21 / 509.75 3 3
Average= 4.14
(KJ/cycle)

Cycle 121 GMT 6/12/2020 17:59: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 22 15.11 2 1 0.00 / 501.33 3 3
2 7 2003.36 44 14.19 3025 1889 1.89 / 503.22 3 3
3 13 1603.40 22 14.32 2518 793 2.68 / 504.02 3 3
4 13 1020.12 22 14.51 1744 557 3.24 / 504.57 3 3
5 13 276.48 22 14.88 720 236 3.48 / 504.81 3 3
6 8 -0.08 165 15.02 294 729 4.20 / 505.54 3 3
Average= 4.14
(KJ/cycle)

Cycle 120 GMT 26/11/2020 18:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.84 22 15.12 1 0 0.00 / 497.12 3 3
2 7 2003.80 44 14.19 3025 1889 1.89 / 499.00 3 3
3 13 1604.04 22 14.32 2527 796 2.69 / 499.80 3 3
4 13 1027.04 22 14.50 1756 560 3.25 / 500.36 3 3
5 13 288.32 22 14.87 745 244 3.49 / 500.60 3 3
6 8 0.00 165 15.02 294 729 4.22 / 501.33 3 3
Average= 4.14
(KJ/cycle)

Cycle 119 GMT 16/11/2020 18:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.64 22 15.11 1 0 0.00 / 492.92 3 3
2 7 2004.40 44 14.19 3025 1889 1.89 / 494.80 3 3
3 13 1595.40 22 14.32 2524 795 2.68 / 495.60 3 3
4 13 1007.52 22 14.52 1727 552 3.24 / 496.15 3 3
5 13 276.32 22 14.88 719 235 3.47 / 496.39 3 3
6 8 0.12 165 15.02 294 729 4.20 / 497.12 3 3
Average= 4.14
(KJ/cycle)

Cycle 118 GMT 6/11/2020 19:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.36 22 15.12 2 1 0.00 / 488.75 3 3
2 7 2004.56 44 14.20 3032 1894 1.90 / 490.65 3 3
3 13 1597.56 22 14.32 2502 788 2.68 / 491.44 3 3
4 13 880.76 22 14.58 1542 495 3.18 / 491.93 3 3
5 13 309.88 22 14.86 767 251 3.43 / 492.18 3 3
6 8 0.00 165 15.02 296 734 4.16 / 492.92 3 3
Average= 4.14
(KJ/cycle)

Cycle 117 GMT 27/10/2020 19:43:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.16 22 15.12 1 0 0.00 / 484.51 3 3
2 7 2002.32 44 14.19 3020 1886 1.89 / 486.39 3 3
3 13 1730.36 22 14.28 2685 844 2.73 / 487.23 3 3
4 13 1003.20 22 14.53 1715 548 3.28 / 487.78 3 3
5 13 275.20 22 14.89 725 237 3.52 / 488.02 3 3
6 8 0.20 165 15.02 296 734 4.25 / 488.75 3 3
Average= 4.14
(KJ/cycle)

Cycle 116 GMT 17/10/2020 20:13: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.28 22 15.12 2 1 0.00 / 480.33 3 3
2 7 2003.08 44 14.19 3019 1885 1.89 / 482.21 3 3
3 13 1607.36 22 14.32 2523 795 2.68 / 483.01 3 3
4 13 900.68 22 14.57 1578 506 3.19 / 483.51 3 3
5 13 317.12 22 14.86 787 257 3.44 / 483.77 3 3
6 8 0.00 165 15.02 296 734 4.18 / 484.50 3 3
Average= 4.14
(KJ/cycle)

Cycle 115 GMT 7/10/2020 20:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.80 22 15.11 2 1 0.00 / 476.10 3 3
2 7 2006.04 44 14.20 3028 1892 1.89 / 477.99 3 3
3 13 1726.72 22 14.28 2697 847 2.74 / 478.84 3 3
4 13 880.40 22 14.58 1552 498 3.24 / 479.34 3 3
5 13 299.92 22 14.87 757 248 3.49 / 479.58 3 3
6 8 0.16 165 15.02 300 743 4.23 / 480.33 3 3
Average= 4.14
(KJ/cycle)

Cycle 114 GMT 27/ 9/2020 20:58: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.24 22 15.12 2 1 0.00 / 471.88 3 3
2 7 2003.68 44 14.19 3031 1892 1.89 / 473.77 3 3
3 13 1730.96 22 14.28 2700 848 2.74 / 474.62 3 3
4 13 877.88 22 14.58 1551 497 3.24 / 475.12 3 3
5 13 299.80 22 14.87 753 246 3.49 / 475.36 3 3
6 8 0.04 165 15.02 297 736 4.22 / 476.10 3 3
Average= 4.14
(KJ/cycle)

Cycle 113 GMT 17/ 9/2020 21:22:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.32 23 15.12 1 0 0.00 / 467.66 3 3
2 3 936.92 -1 15.42 0 0 0.00 / 467.66 3 3
3 7 2004.44 44 14.19 3024 1888 1.89 / 469.55 3 3
4 13 1597.76 22 14.33 2520 794 2.68 / 470.34 3 3
5 13 1016.20 22 14.52 1736 555 3.24 / 470.90 3 3
6 13 277.88 22 14.88 723 237 3.47 / 471.13 3 3
7 8 0.08 165 15.02 300 743 4.22 / 471.88 3 3
Average= 4.14
(KJ/cycle)

Cycle 112 GMT 7/ 9/2020 21:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.84 22 15.10 2 1 0.00 / 463.42 3 3
2 3 1020.36 1 15.41 2 0 0.00 / 463.42 3 3
3 7 2008.72 44 14.19 3032 1893 1.89 / 465.31 3 3
4 13 1737.08 22 14.28 2696 847 2.74 / 466.16 3 3
5 13 985.28 22 14.54 1695 542 3.28 / 466.70 3 3
6 13 250.32 22 14.90 677 222 3.50 / 466.92 3 3
7 8 -0.12 165 15.02 297 736 4.24 / 467.66 3 3
Average= 4.14
(KJ/cycle)

Cycle 111 GMT 28/ 8/2020 22: 7: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.00 22 15.13 2 1 0.00 / 458.88 3 3
2 3 1022.48 1 15.42 3 0 0.00 / 458.88 3 3
3 7 2002.40 44 14.19 3016 1883 1.88 / 460.76 3 3
4 13 1599.72 22 14.34 2506 791 2.67 / 461.55 3 3
5 13 1019.64 22 14.52 1739 556 3.23 / 462.11 3 3
6 13 272.76 22 14.88 719 235 3.47 / 462.34 3 3
7 8 0.04 165 15.02 299 741 4.21 / 463.09 3 3
8 14 0.04 75 14.98 297 334 4.54 / 463.42 3 4
Average= 4.14
(KJ/cycle)

Cycle 110 GMT 18/ 8/2020 22:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.36 21 15.12 2 1 0.00 / 454.77 3 3
2 3 1019.88 1 15.42 2 0 0.00 / 454.77 3 3
3 7 2003.20 44 14.20 3020 1887 1.89 / 456.65 3 3
4 13 1606.60 22 14.33 2521 795 2.68 / 457.45 3 3
5 13 902.04 22 14.58 1576 506 3.19 / 457.95 3 3
6 13 191.24 22 14.95 588 193 3.38 / 458.15 3 3
7 8 0.28 165 15.02 295 731 4.11 / 458.88 3 3
Average= 4.13
(KJ/cycle)

Cycle 109 GMT 8/ 8/2020 22:52: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.24 22 15.12 1 0 0.00 / 450.52 3 3
2 3 971.40 -1 15.42 0 0 0.00 / 450.52 3 3
3 7 2001.80 44 14.19 3025 1889 1.89 / 452.41 3 3
4 13 1728.12 22 14.29 2690 846 2.73 / 453.26 3 3
5 13 983.40 22 14.54 1692 541 3.28 / 453.80 3 3
6 13 251.60 22 14.91 689 226 3.50 / 454.03 3 3
7 8 0.04 165 15.02 299 741 4.24 / 454.77 3 3
Average= 4.13
(KJ/cycle)

Cycle 108 GMT 29/ 7/2020 23:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.96 22 15.12 2 1 0.00 / 446.37 3 3
2 3 1027.52 1 15.42 3 0 0.00 / 446.37 3 3
3 7 2003.08 44 14.19 3028 1891 1.89 / 448.26 3 3
4 13 1600.32 22 14.34 2500 789 2.68 / 449.05 3 3
5 13 876.60 22 14.59 1546 496 3.18 / 449.54 3 3
6 13 281.16 22 14.88 735 241 3.42 / 449.79 3 3
7 8 0.16 165 15.02 298 739 4.16 / 450.52 3 3
Average= 4.13
(KJ/cycle)

Cycle 107 GMT 19/ 7/2020 23:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.76 22 15.12 2 1 0.00 / 442.27 3 3
2 7 2004.48 44 14.20 3026 1891 1.89 / 444.16 3 3
3 13 1477.32 22 14.38 2353 744 2.64 / 444.90 3 3
4 13 922.64 22 14.56 1614 517 3.15 / 445.42 3 3
5 13 206.88 22 14.93 621 204 3.36 / 445.62 3 3
6 8 0.24 165 15.02 301 746 4.10 / 446.37 3 3
Average= 4.13
(KJ/cycle)

Cycle 106 GMT 10/ 7/2020 0: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.92 22 15.13 2 1 0.00 / 438.12 3 3
2 7 2003.56 44 14.20 3026 1891 1.89 / 440.01 3 3
3 13 1585.20 22 14.34 2502 789 2.68 / 440.80 3 3
4 13 863.72 22 14.59 1536 493 3.17 / 441.29 3 3
5 13 279.96 22 14.89 731 239 3.41 / 441.53 3 3
6 8 0.16 165 15.03 297 737 4.15 / 442.27 3 3
Average= 4.13
(KJ/cycle)

Cycle 105 GMT 30/ 6/2020 0:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.60 22 15.12 2 1 0.00 / 433.81 3 3
2 7 2008.00 44 14.20 3032 1894 1.90 / 435.71 3 3
3 13 1734.12 22 14.29 2693 847 2.74 / 436.55 3 3
4 13 1121.92 22 14.48 1882 600 3.34 / 437.15 3 3
5 13 225.20 22 14.92 656 215 3.56 / 437.37 3 3
6 8 0.04 165 15.03 301 746 4.30 / 438.12 3 3
Average= 4.13
(KJ/cycle)

Cycle 104 GMT 20/ 6/2020 0:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.60 22 15.12 1 0 0.00 / 429.63 3 3
2 7 2008.72 44 14.19 3024 1888 1.89 / 431.52 3 3
3 13 1602.04 22 14.33 2523 795 2.68 / 432.31 3 3
4 13 898.04 22 14.58 1583 508 3.19 / 432.82 3 3
5 13 314.44 22 14.87 781 255 3.45 / 433.07 3 3
6 8 0.16 165 15.02 298 739 4.19 / 433.81 3 3
Average= 4.13
(KJ/cycle)

Cycle 103 GMT 10/ 6/2020 1: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.16 22 15.13 1 0 0.00 / 425.36 3 3
2 7 2008.16 45 14.19 3036 1939 1.94 / 427.30 3 3
3 13 1598.32 22 14.33 2527 797 2.74 / 428.10 3 3
4 13 1008.20 22 14.53 1730 553 3.29 / 428.65 3 3
5 13 271.68 22 14.89 719 236 3.52 / 428.89 3 3
6 8 0.00 165 15.02 299 741 4.27 / 429.63 3 3
Average= 4.13
(KJ/cycle)

Cycle 102 GMT 31/ 5/2020 1:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.84 22 15.13 1 0 0.00 / 421.26 3 3
2 7 2004.84 44 14.20 3026 1891 1.89 / 423.15 3 3
3 13 1609.08 22 14.34 2521 795 2.69 / 423.94 3 3
4 13 887.24 22 14.59 1565 502 3.19 / 424.44 3 3
5 13 179.68 22 14.96 577 190 3.38 / 424.63 3 3
6 8 0.20 165 15.03 294 729 4.11 / 425.36 3 3
Average= 4.13
(KJ/cycle)

Cycle 101 GMT 21/ 5/2020 1:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.12 22 15.13 2 1 0.00 / 416.99 3 3
2 7 2008.96 44 14.20 3035 1896 1.90 / 418.89 3 3
3 13 1741.92 22 14.29 2709 852 2.75 / 419.74 3 3
4 13 990.92 22 14.55 1700 544 3.29 / 420.28 3 3
5 13 265.12 22 14.90 710 233 3.53 / 420.52 3 3
6 8 0.04 165 15.03 298 739 4.26 / 421.25 3 3
Average= 4.13
(KJ/cycle)

Cycle 100 GMT 11/ 5/2020 2: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.08 23 15.13 1 0 0.00 / 412.74 3 3
2 3 970.16 -1 15.43 0 0 0.00 / 412.74 3 3
3 7 2007.68 44 14.20 3028 1892 1.89 / 414.63 3 3
4 13 1727.24 22 14.30 2697 848 2.74 / 415.48 3 3
5 13 986.04 22 14.55 1702 545 3.29 / 416.03 3 3
6 13 256.48 22 14.90 703 230 3.52 / 416.26 3 3
7 8 0.16 165 15.03 296 734 4.25 / 416.99 3 3
Average= 4.13
(KJ/cycle)

Cycle 99 GMT 1/ 5/2020 2:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.84 21 15.13 1 0 0.00 / 408.52 3 3
2 3 1064.96 2 15.42 2 0 0.00 / 408.52 3 3
3 7 2002.72 44 14.20 3011 1881 1.88 / 410.40 3 3
4 13 1727.04 22 14.30 2682 844 2.73 / 411.25 3 3
5 13 973.24 22 14.55 1683 539 3.26 / 411.79 3 3
6 13 244.96 22 14.91 678 222 3.49 / 412.01 3 3
7 8 0.16 165 15.03 295 732 4.22 / 412.74 3 3
Average= 4.13
(KJ/cycle)

Cycle 98 GMT 21/ 4/2020 2:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.72 22 15.13 1 0 0.00 / 404.26 3 3
2 3 968.76 -1 15.43 0 0 0.00 / 404.26 3 3
3 7 2009.16 44 14.20 3024 1889 1.89 / 406.15 3 3
4 13 1741.68 22 14.30 2709 852 2.74 / 407.00 3 3
5 13 1004.08 22 14.54 1715 549 3.29 / 407.55 3 3
6 13 269.64 22 14.90 718 235 3.53 / 407.78 3 3
7 8 -0.04 165 15.03 298 739 4.26 / 408.52 3 3
Average= 4.13
(KJ/cycle)

Cycle 97 GMT 11/ 4/2020 3:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.36 23 15.14 1 0 0.00 / 400.06 3 3
2 3 963.08 -1 15.43 0 0 0.00 / 400.06 3 3
3 7 2002.92 44 14.20 3026 1891 1.89 / 401.95 3 3
4 13 1592.76 22 14.35 2497 788 2.68 / 402.74 3 3
5 13 1004.60 22 14.54 1730 553 3.23 / 403.29 3 3
6 13 263.64 22 14.90 708 232 3.46 / 403.52 3 3
7 8 0.08 165 15.03 297 737 4.20 / 404.26 3 3
Average= 4.13
(KJ/cycle)

Cycle 96 GMT 1/ 4/2020 3:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.24 23 15.14 1 0 0.00 / 395.95 3 3
2 3 1022.92 1 15.43 3 0 0.00 / 395.95 3 3
3 7 2003.76 44 14.21 3027 1893 1.89 / 397.84 3 3
4 13 1596.12 22 14.34 2512 792 2.69 / 398.64 3 3
5 13 889.12 22 14.60 1557 500 3.19 / 399.14 3 3
6 13 181.20 22 14.96 579 191 3.38 / 399.33 3 3
7 8 0.28 165 15.04 294 730 4.11 / 400.06 3 3
Average= 4.12
(KJ/cycle)

Cycle 95 GMT 22/ 3/2020 4: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.76 23 15.13 1 0 0.00 / 391.80 3 3
2 7 2002.80 44 14.20 3025 1890 1.89 / 393.69 3 3
3 13 1593.08 22 14.35 2492 787 2.68 / 394.48 3 3
4 13 884.36 22 14.60 1558 500 3.18 / 394.98 3 3
5 13 294.56 22 14.88 751 246 3.42 / 395.23 3 3
6 8 -0.08 165 15.04 292 725 4.15 / 395.95 3 3
Average= 4.12
(KJ/cycle)

Cycle 94 GMT 12/ 3/2020 4: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 23 15.14 1 0 0.00 / 387.53 3 3
2 3 1021.32 1 15.44 3 0 0.00 / 387.53 3 3
3 7 2009.00 44 14.20 3028 1892 1.89 / 389.43 3 3
4 13 1589.80 22 14.35 2504 791 2.68 / 390.22 3 3
5 13 874.12 22 14.60 1545 496 3.18 / 390.71 3 3
6 13 284.52 22 14.89 734 240 3.42 / 390.95 3 3
7 13 25.16 22 15.05 341 113 3.53 / 391.07 3 3
8 8 0.00 165 15.03 297 737 4.27 / 391.80 3 3
Average= 4.12
(KJ/cycle)

Cycle 93 GMT 2/ 3/2020 4:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.76 23 15.13 1 0 0.00 / 383.35 3 3
2 7 2003.28 44 14.20 3023 1889 1.89 / 385.24 3 3
3 13 1593.00 22 14.35 2506 791 2.68 / 386.03 3 3
4 13 1001.52 22 14.54 1713 548 3.23 / 386.58 3 3
5 13 252.16 22 14.92 695 228 3.46 / 386.81 3 3
6 8 0.04 165 15.04 293 727 4.18 / 387.53 3 3
Average= 4.12
(KJ/cycle)

Cycle 92 GMT 21/ 2/2020 4:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.40 23 15.13 1 0 0.00 / 379.10 3 3
2 7 2003.48 44 14.21 3016 1886 1.89 / 380.98 3 3
3 13 1606.24 22 14.34 2522 796 2.68 / 381.78 3 3
4 13 880.48 22 14.61 1550 498 3.18 / 382.28 3 3
5 13 286.60 22 14.90 737 242 3.42 / 382.52 3 3
6 13 26.04 22 15.05 334 111 3.53 / 382.63 3 3
7 8 0.16 165 15.03 291 722 4.25 / 383.35 3 3
Average= 4.12
(KJ/cycle)

Cycle 91 GMT 11/ 2/2020 5:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.80 23 15.14 1 0 0.00 / 374.79 3 3
2 7 2004.92 44 14.20 3019 1886 1.89 / 376.68 3 3
3 13 1600.04 22 14.34 2523 796 2.68 / 377.48 3 3
4 13 1008.96 22 14.54 1724 551 3.23 / 378.03 3 3
5 13 271.64 22 14.91 718 236 3.47 / 378.26 3 3
6 13 23.88 22 15.06 336 111 3.58 / 378.37 3 3
7 8 0.00 165 15.03 291 722 4.30 / 379.10 3 3
Average= 4.12
(KJ/cycle)

Cycle 90 GMT 1/ 2/2020 5:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.44 22 15.14 1 0 0.00 / 370.46 3 3
2 3 1030.52 1 15.44 3 0 0.00 / 370.46 3 3
3 7 2003.08 44 14.19 3029 1891 1.89 / 372.36 3 3
4 13 1729.72 22 14.30 2687 845 2.74 / 373.20 3 3
5 13 977.00 22 14.56 1686 540 3.28 / 373.74 3 3
6 13 242.08 22 14.93 672 221 3.50 / 373.96 3 3
7 13 22.24 22 15.06 330 109 3.61 / 374.07 3 3
8 8 0.08 165 15.04 291 722 4.33 / 374.79 3 3
Average= 4.12
(KJ/cycle)

Cycle 89 GMT 22/ 1/2020 5:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.60 22 15.14 1 0 0.00 / 366.38 3 3
2 7 2009.76 44 14.20 3023 1889 1.89 / 368.27 3 3
3 13 1481.48 22 14.39 2359 747 2.64 / 369.01 3 3
4 13 927.36 22 14.58 1615 518 3.15 / 369.53 3 3
5 13 211.64 22 14.95 634 209 3.36 / 369.74 3 3
6 8 0.08 165 15.05 292 725 4.09 / 370.46 3 3
Average= 4.12
(KJ/cycle)

Cycle 88 GMT 12/ 1/2020 5:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.12 22 15.14 1 0 0.00 / 362.19 3 3
2 7 2003.76 44 14.20 3019 1886 1.89 / 364.07 3 3
3 13 1729.56 22 14.31 2680 844 2.73 / 364.92 3 3
4 13 863.52 22 14.62 1534 493 3.22 / 365.41 3 3
5 13 278.40 22 14.91 723 237 3.46 / 365.65 3 3
6 8 0.16 165 15.04 294 730 4.19 / 366.38 3 3
Average= 4.12
(KJ/cycle)

Cycle 87 GMT 2/ 1/2020 6:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.76 22 15.14 2 1 0.00 / 357.97 3 3
2 7 2005.36 44 14.20 3021 1888 1.89 / 359.86 3 3
3 13 1729.08 22 14.31 2681 844 2.73 / 360.70 3 3
4 13 971.44 22 14.56 1678 537 3.27 / 361.24 3 3
5 13 247.64 22 14.93 676 222 3.49 / 361.46 3 3
6 8 0.04 165 15.05 293 728 4.22 / 362.19 3 3
Average= 4.12
(KJ/cycle)

Cycle 86 GMT 23/12/2019 6:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.60 22 15.14 2 1 0.00 / 353.81 3 3
2 7 2002.04 44 14.21 3026 1892 1.89 / 355.70 3 3
3 13 1594.76 22 14.35 2505 791 2.68 / 356.49 3 3
4 13 881.84 22 14.61 1553 499 3.18 / 356.99 3 3
5 13 296.16 22 14.90 744 244 3.43 / 357.23 3 3
6 8 0.12 165 15.04 296 735 4.16 / 357.97 3 3
Average= 4.11
(KJ/cycle)

Cycle 85 GMT 13/12/2019 6:59: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.28 22 15.14 2 1 0.00 / 349.62 3 3
2 7 2007.48 44 14.20 3027 1891 1.89 / 351.52 3 3
3 13 1481.52 22 14.39 2351 744 2.64 / 352.26 3 3
4 13 1046.32 22 14.53 1782 570 3.21 / 352.83 3 3
5 13 286.44 22 14.90 738 242 3.45 / 353.07 3 3
6 8 0.04 165 15.04 296 735 4.18 / 353.81 3 3
Average= 4.11
(KJ/cycle)

Cycle 84 GMT 3/12/2019 7:10:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.44 21 15.14 2 1 0.00 / 345.41 3 3
2 7 2006.68 44 14.20 3029 1893 1.89 / 347.30 3 3
3 13 1590.40 22 14.35 2504 791 2.68 / 348.09 3 3
4 13 1006.56 22 14.55 1719 550 3.23 / 348.65 3 3
5 13 269.00 22 14.91 713 234 3.47 / 348.88 3 3
6 8 0.20 165 15.04 300 744 4.21 / 349.62 3 3
Average= 4.11
(KJ/cycle)

Cycle 83 GMT 23/11/2019 7:31:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.12 21 15.13 2 1 0.00 / 341.30 3 3
2 7 2007.24 44 14.21 3018 1887 1.89 / 343.19 3 3
3 13 1604.16 22 14.35 2507 791 2.68 / 343.98 3 3
4 13 899.00 22 14.60 1569 504 3.18 / 344.48 3 3
5 13 189.40 22 14.97 590 194 3.38 / 344.68 3 3
6 8 -0.04 165 15.04 296 735 4.11 / 345.41 3 3
Average= 4.11
(KJ/cycle)

Cycle 82 GMT 13/11/2019 7:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.32 21 15.14 2 1 0.00 / 337.10 3 3
2 7 2006.76 44 14.21 3026 1892 1.89 / 338.99 3 3
3 13 1601.72 22 14.36 2507 792 2.68 / 339.78 3 3
4 13 1005.16 22 14.55 1717 550 3.23 / 340.33 3 3
5 13 251.92 22 14.92 685 225 3.46 / 340.56 3 3
6 8 0.08 165 15.04 299 742 4.20 / 341.30 3 3
Average= 4.11
(KJ/cycle)

Cycle 81 GMT 3/11/2019 7:55:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.76 22 15.14 2 1 0.00 / 332.98 3 3
2 3 969.08 -1 15.47 0 0 0.00 / 332.98 3 3
3 7 2005.16 44 14.21 3017 1886 1.89 / 334.87 3 3
4 13 1599.00 22 14.36 2518 795 2.68 / 335.66 3 3
5 13 889.44 22 14.61 1561 502 3.18 / 336.17 3 3
6 13 184.16 22 14.97 584 192 3.38 / 336.36 3 3
7 8 0.12 165 15.04 298 740 4.12 / 337.10 3 3
Average= 4.11
(KJ/cycle)

Cycle 80 GMT 24/10/2019 8: 2: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.64 21 15.13 1 0 0.00 / 328.82 3 3
2 3 1047.36 1 15.44 3 0 0.00 / 328.82 3 3
3 7 2003.44 44 14.21 3018 1887 1.89 / 330.71 3 3
4 13 1740.92 22 14.31 2707 852 2.74 / 331.56 3 3
5 13 876.60 22 14.62 1546 497 3.24 / 332.06 3 3
6 13 176.20 22 14.98 569 188 3.42 / 332.25 3 3
7 8 0.08 165 15.04 297 737 4.16 / 332.98 3 3
Average= 4.11
(KJ/cycle)

Cycle 79 GMT 14/10/2019 8:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.48 21 15.13 1 0 0.00 / 324.67 3 3
2 7 2003.00 44 14.22 3018 1888 1.89 / 326.56 3 3
3 13 1590.56 22 14.36 2502 790 2.68 / 327.35 3 3
4 13 859.40 22 14.62 1520 489 3.17 / 327.84 3 3
5 13 281.92 22 14.91 727 238 3.41 / 328.08 3 3
6 8 0.04 165 15.04 300 744 4.15 / 328.82 3 3
Average= 4.11
(KJ/cycle)

Cycle 78 GMT 4/10/2019 8:46: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.88 21 15.13 2 1 0.00 / 320.43 3 3
2 7 2005.60 44 14.22 3029 1895 1.90 / 322.33 3 3
3 13 1738.32 22 14.31 2711 853 2.75 / 323.18 3 3
4 13 863.96 22 14.62 1528 491 3.24 / 323.67 3 3
5 13 296.16 22 14.90 755 247 3.49 / 323.92 3 3
6 8 0.16 165 15.04 302 749 4.24 / 324.67 3 3
Average= 4.11
(KJ/cycle)

Cycle 77 GMT 24/ 9/2019 8:58: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.88 21 15.13 2 1 0.00 / 316.26 3 3
2 3 973.32 -1 15.46 0 0 0.00 / 316.26 3 3
3 7 2006.76 44 14.21 3024 1891 1.89 / 318.15 3 3
4 13 1593.88 22 14.37 2497 789 2.68 / 318.94 3 3
5 13 886.84 22 14.62 1554 500 3.18 / 319.44 3 3
6 13 300.32 22 14.90 753 247 3.43 / 319.69 3 3
7 8 0.12 165 15.04 301 747 4.17 / 320.43 3 3
Average= 4.11
(KJ/cycle)

Cycle 76 GMT 14/ 9/2019 9:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.80 21 15.14 2 1 0.00 / 312.04 3 3
2 7 2003.96 44 14.21 3017 1886 1.89 / 313.92 3 3
3 13 1602.20 22 14.36 2516 795 2.68 / 314.72 3 3
4 13 1006.76 22 14.56 1720 551 3.23 / 315.27 3 3
5 13 266.48 22 14.92 706 232 3.46 / 315.50 3 3
6 8 0.12 165 15.03 305 756 4.22 / 316.26 3 3
Average= 4.11
(KJ/cycle)

Cycle 75 GMT 4/ 9/2019 9:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.20 22 15.14 2 1 0.00 / 307.94 3 3
2 3 969.16 -1 15.44 0 0 0.00 / 307.94 3 3
3 7 2008.28 44 14.22 3025 1893 1.89 / 309.83 3 3
4 13 1478.60 22 14.41 2348 744 2.64 / 310.58 3 3
5 13 911.28 22 14.60 1586 509 3.15 / 311.08 3 3
6 13 198.00 22 14.96 609 200 3.35 / 311.28 3 3
7 8 0.00 165 15.04 303 752 4.10 / 312.04 3 3
Average= 4.11
(KJ/cycle)

Cycle 74 GMT 25/ 8/2019 9:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.36 23 15.14 2 1 0.00 / 303.71 3 3
2 3 973.60 -1 15.47 0 0 0.00 / 303.71 3 3
3 7 2007.64 44 14.22 3019 1889 1.89 / 305.60 3 3
4 13 1735.48 22 14.32 2700 851 2.74 / 306.45 3 3
5 13 862.32 22 14.63 1519 489 3.23 / 306.94 3 3
6 13 280.44 22 14.92 730 240 3.47 / 307.18 3 3
7 8 0.04 165 15.04 306 759 4.23 / 307.94 3 3
Average= 4.11
(KJ/cycle)

Cycle 73 GMT 15/ 8/2019 10: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.04 23 15.14 2 1 0.00 / 299.57 3 3
2 7 2007.68 44 14.22 3039 1901 1.90 / 301.47 3 3
3 13 1596.48 22 14.37 2505 792 2.69 / 302.26 3 3
4 13 891.20 22 14.62 1559 501 3.20 / 302.77 3 3
5 13 188.72 22 14.98 588 194 3.39 / 302.96 3 3
6 8 -0.08 165 15.05 302 750 4.14 / 303.71 3 3
Average= 4.10
(KJ/cycle)

Cycle 72 GMT 5/ 8/2019 10:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.44 22 15.15 2 1 0.00 / 295.26 3 3
2 7 2008.16 44 14.22 3035 1899 1.90 / 297.16 3 3
3 13 1607.76 22 14.37 2524 798 2.70 / 297.96 3 3
4 13 888.20 22 14.62 1562 502 3.20 / 298.46 3 3
5 13 289.48 22 14.92 738 242 3.44 / 298.71 3 3
6 13 28.04 22 15.06 347 115 3.56 / 298.82 3 3
7 8 0.00 165 15.04 302 749 4.31 / 299.57 3 3
Average= 4.10
(KJ/cycle)

Cycle 71 GMT 26/ 7/2019 10:25: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.88 22 15.15 2 1 0.00 / 291.04 3 3
2 3 1022.16 1 15.44 3 0 0.00 / 291.04 3 3
3 7 2003.44 44 14.24 3025 1895 1.90 / 292.94 3 3
4 13 1592.12 22 14.38 2497 790 2.69 / 293.73 3 3
5 13 1012.52 22 14.57 1737 557 3.24 / 294.28 3 3
6 13 264.84 22 14.93 705 232 3.47 / 294.51 3 3
7 8 0.24 165 15.05 302 750 4.22 / 295.26 3 3
Average= 4.10
(KJ/cycle)

Cycle 70 GMT 16/ 7/2019 10:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.96 22 15.15 2 1 0.00 / 286.83 3 3
2 7 2002.88 44 14.23 3026 1895 1.90 / 288.73 3 3
3 13 1595.88 22 14.38 2507 793 2.69 / 289.52 3 3
4 13 1000.64 22 14.58 1710 548 3.24 / 290.07 3 3
5 13 255.16 22 14.94 692 227 3.46 / 290.29 3 3
6 8 0.40 165 15.05 300 745 4.21 / 291.04 3 3
Average= 4.10
(KJ/cycle)

Cycle 69 GMT 6/ 7/2019 11:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.92 22 15.16 2 1 0.00 / 282.67 3 3
2 7 2003.72 45 14.24 3031 1942 1.94 / 284.61 3 3
3 13 1586.88 22 14.39 2501 792 2.73 / 285.40 3 3
4 13 880.64 22 14.63 1552 500 3.23 / 285.90 3 3
5 13 172.92 22 15.00 571 188 3.42 / 286.09 3 3
6 8 0.08 165 15.06 297 738 4.16 / 286.83 3 3
Average= 4.10
(KJ/cycle)

Cycle 68 GMT 26/ 6/2019 11:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.16 22 15.15 2 1 0.00 / 278.47 3 3
2 7 2004.32 44 14.24 3036 1902 1.90 / 280.37 3 3
3 13 1582.48 22 14.39 2476 784 2.69 / 281.16 3 3
4 13 992.76 22 14.58 1705 547 3.23 / 281.71 3 3
5 13 244.40 22 14.95 679 223 3.46 / 281.93 3 3
6 8 0.08 165 15.06 298 741 4.20 / 282.67 3 3
Average= 4.10
(KJ/cycle)

Cycle 67 GMT 16/ 6/2019 11:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.08 21 15.17 2 1 0.00 / 274.31 3 3
2 3 1039.00 1 15.45 2 0 0.00 / 274.31 3 3
3 7 2001.76 44 14.25 3016 1891 1.89 / 276.20 3 3
4 13 1583.12 22 14.40 2482 786 2.68 / 276.99 3 3
5 13 866.36 22 14.65 1530 493 3.17 / 277.48 3 3
6 13 275.20 22 14.93 723 237 3.41 / 277.72 3 3
7 8 0.08 165 15.06 303 753 4.16 / 278.47 3 3
Average= 4.10
(KJ/cycle)

Cycle 66 GMT 6/ 6/2019 11:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.16 23 15.16 1 0 0.00 / 270.17 3 3
2 3 950.48 -1 15.45 0 0 0.00 / 270.17 3 3
3 7 2007.88 44 14.24 3031 1899 1.90 / 272.07 3 3
4 13 1462.60 22 14.44 2338 743 2.64 / 272.81 3 3
5 13 891.16 22 14.64 1566 504 3.15 / 273.31 3 3
6 13 296.80 22 14.92 755 248 3.39 / 273.56 3 3
7 8 0.20 165 15.06 301 748 4.14 / 274.31 3 3
Average= 4.09
(KJ/cycle)

Cycle 65 GMT 27/ 5/2019 12: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.48 23 15.16 2 1 0.00 / 266.00 3 3
2 7 2004.12 44 14.25 3028 1899 1.90 / 267.90 3 3
3 13 1599.88 22 14.39 2523 799 2.70 / 268.70 3 3
4 13 877.44 22 14.65 1536 495 3.19 / 269.19 3 3
5 13 284.12 22 14.93 735 241 3.43 / 269.43 3 3
6 8 -0.04 165 15.07 295 734 4.17 / 270.17 3 3
Average= 4.09
(KJ/cycle)

Cycle 64 GMT 17/ 5/2019 12:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.00 22 15.17 2 1 0.00 / 261.77 3 3
2 7 2007.60 44 14.25 3040 1906 1.91 / 263.67 3 3
3 13 1587.64 22 14.41 2500 793 2.70 / 264.47 3 3
4 13 877.92 22 14.66 1543 498 3.20 / 264.96 3 3
5 13 171.36 22 15.01 570 188 3.39 / 265.15 3 3
6 13 15.08 22 15.10 322 107 3.49 / 265.26 3 3
7 8 0.08 165 15.07 298 741 4.23 / 266.00 3 3
Average= 4.09
(KJ/cycle)

Cycle 63 GMT 7/ 5/2019 12:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.08 22 15.17 2 1 0.00 / 257.56 3 3
2 7 2003.40 44 14.25 3021 1894 1.89 / 259.45 3 3
3 13 1727.36 22 14.36 2693 851 2.75 / 260.30 3 3
4 13 856.92 22 14.67 1521 491 3.24 / 260.79 3 3
5 13 273.44 22 14.95 719 236 3.47 / 261.03 3 3
6 8 0.16 165 15.08 297 739 4.21 / 261.77 3 3
Average= 4.09
(KJ/cycle)

Cycle 62 GMT 27/ 4/2019 12:34: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.44 23 15.18 2 1 0.00 / 253.35 3 3
2 7 2004.64 44 14.26 3028 1900 1.90 / 255.25 3 3
3 13 1582.92 22 14.41 2498 792 2.69 / 256.04 3 3
4 13 996.28 22 14.61 1704 548 3.24 / 256.59 3 3
5 13 247.12 22 14.97 682 225 3.46 / 256.81 3 3
6 8 0.20 165 15.08 298 741 4.21 / 257.55 3 3
Average= 4.09
(KJ/cycle)

Cycle 61 GMT 17/ 4/2019 12:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.16 23 15.17 2 1 0.00 / 249.28 3 3
2 7 2001.76 44 14.25 3026 1897 1.90 / 251.18 3 3
3 13 1595.12 22 14.41 2515 797 2.70 / 251.97 3 3
4 13 749.52 22 14.73 1370 444 3.14 / 252.42 3 3
5 13 191.52 22 15.00 601 198 3.34 / 252.62 3 3
6 8 0.04 165 15.09 294 732 4.07 / 253.35 3 3
Average= 4.09
(KJ/cycle)

Cycle 60 GMT 7/ 4/2019 12:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.72 23 15.17 2 1 0.00 / 245.06 3 3
2 7 2007.80 44 14.26 3028 1900 1.90 / 246.96 3 3
3 13 1478.00 22 14.46 2342 745 2.65 / 247.71 3 3
4 13 919.56 22 14.65 1600 516 3.16 / 248.22 3 3
5 13 194.60 22 15.01 602 199 3.36 / 248.42 3 3
6 13 38.48 22 15.09 362 120 3.48 / 248.54 3 3
7 8 -0.16 165 15.08 296 737 4.22 / 249.28 3 3
Average= 4.09
(KJ/cycle)

Cycle 59 GMT 28/ 3/2019 12:50: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.32 23 15.19 2 1 0.00 / 240.79 3 3
2 7 2006.00 44 14.26 3025 1898 1.90 / 242.69 3 3
3 13 1579.80 22 14.42 2497 792 2.69 / 243.48 3 3
4 13 870.92 22 14.68 1531 494 3.19 / 243.98 3 3
5 13 269.48 22 14.96 714 235 3.42 / 244.21 3 3
6 13 24.00 22 15.10 340 113 3.53 / 244.33 3 3
7 8 -0.08 165 15.08 296 737 4.27 / 245.06 3 3
Average= 4.08
(KJ/cycle)

Cycle 58 GMT 18/ 3/2019 13: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.88 23 15.19 2 1 0.00 / 236.70 3 3
2 7 2005.56 44 14.27 3025 1899 1.90 / 238.60 3 3
3 13 1599.72 22 14.42 2533 804 2.70 / 239.40 3 3
4 13 765.24 22 14.73 1398 453 3.16 / 239.86 3 3
5 13 197.32 22 15.01 610 201 3.36 / 240.06 3 3
6 8 0.16 165 15.09 295 735 4.09 / 240.79 3 3
Average= 4.08
(KJ/cycle)

Cycle 57 GMT 8/ 3/2019 13: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.08 23 15.19 2 1 0.00 / 232.53 3 3
2 7 2003.60 44 14.27 3035 1906 1.91 / 234.44 3 3
3 13 1588.64 22 14.43 2501 794 2.70 / 235.23 3 3
4 13 863.92 22 14.69 1528 494 3.19 / 235.73 3 3
5 13 273.32 22 14.97 715 235 3.43 / 235.96 3 3
6 8 0.04 165 15.09 296 737 4.17 / 236.70 3 3
Average= 4.08
(KJ/cycle)

Cycle 56 GMT 26/ 2/2019 13: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.72 22 15.18 2 1 0.00 / 228.31 3 3
2 7 2004.16 44 14.28 3031 1904 1.91 / 230.22 3 3
3 13 1598.84 22 14.43 2501 794 2.70 / 231.01 3 3
4 13 1013.84 22 14.62 1728 556 3.25 / 231.57 3 3
5 13 262.48 22 14.98 703 232 3.49 / 231.80 3 3
6 8 0.12 165 15.10 294 733 4.22 / 232.53 3 3
Average= 4.08
(KJ/cycle)

Cycle 55 GMT 16/ 2/2019 13:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.68 23 15.19 2 1 0.00 / 223.96 3 3
2 7 2003.56 44 14.28 3035 1907 1.91 / 225.87 3 3
3 13 1606.16 22 14.42 2537 805 2.71 / 226.67 3 3
4 13 1012.56 22 14.63 1729 556 3.27 / 227.23 3 3
5 13 255.24 22 14.98 693 228 3.50 / 227.46 3 3
6 13 21.16 22 15.11 339 113 3.61 / 227.57 3 3
7 8 0.04 165 15.09 298 742 4.35 / 228.31 3 3
Average= 4.08
(KJ/cycle)

Cycle 54 GMT 6/ 2/2019 13:41: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.80 22 15.20 2 1 0.00 / 219.82 3 3
2 3 1020.04 1 15.46 3 0 0.00 / 219.82 3 3
3 7 2004.72 44 14.28 3025 1901 1.90 / 221.72 3 3
4 13 1471.80 22 14.48 2333 743 2.64 / 222.46 3 3
5 13 903.20 22 14.68 1568 506 3.15 / 222.97 3 3
6 13 312.36 22 14.95 774 255 3.41 / 223.22 3 3
7 8 0.00 165 15.10 297 740 4.15 / 223.96 3 3
Average= 4.07
(KJ/cycle)

Cycle 53 GMT 27/ 1/2019 13:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.48 22 15.20 1 0 0.00 / 215.61 3 3
2 7 2009.08 44 14.28 3032 1905 1.91 / 217.52 3 3
3 13 1474.88 22 14.48 2342 746 2.65 / 218.26 3 3
4 13 1039.24 22 14.62 1768 569 3.22 / 218.83 3 3
5 13 278.76 22 14.97 732 241 3.46 / 219.07 3 3
6 8 -0.04 165 15.10 298 742 4.20 / 219.82 3 3
Average= 4.07
(KJ/cycle)

Cycle 52 GMT 17/ 1/2019 13:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.68 22 15.20 2 1 0.00 / 211.43 3 3
2 7 2004.48 44 14.28 3033 1906 1.91 / 213.34 3 3
3 13 1586.88 22 14.44 2509 797 2.70 / 214.14 3 3
4 13 862.80 22 14.70 1528 494 3.20 / 214.63 3 3
5 13 259.28 22 14.99 703 232 3.43 / 214.86 3 3
6 8 0.20 165 15.11 301 750 4.18 / 215.61 3 3
Average= 4.07
(KJ/cycle)

Cycle 51 GMT 7/ 1/2019 14: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.24 22 15.20 2 1 0.00 / 207.29 3 3
2 7 2003.12 44 14.29 3037 1910 1.91 / 209.20 3 3
3 13 1594.20 22 14.44 2518 800 2.71 / 210.00 3 3
4 13 880.52 22 14.70 1542 499 3.21 / 210.50 3 3
5 13 172.24 22 15.05 569 188 3.40 / 210.69 3 3
6 8 0.16 165 15.11 299 745 4.14 / 211.43 3 3
Average= 4.07
(KJ/cycle)

Cycle 50 GMT 28/12/2018 14:13: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.28 22 15.21 2 1 0.00 / 203.16 3 3
2 7 2003.84 44 14.30 3026 1904 1.90 / 205.06 3 3
3 13 1594.48 22 14.45 2520 801 2.71 / 205.86 3 3
4 13 875.36 22 14.71 1538 498 3.20 / 206.36 3 3
5 13 170.00 22 15.06 561 186 3.39 / 206.54 3 3
6 8 0.00 165 15.11 299 745 4.13 / 207.29 3 3
Average= 4.06
(KJ/cycle)

Cycle 49 GMT 18/12/2018 14:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.00 22 15.20 2 1 0.00 / 199.10 3 3
2 7 2003.84 44 14.30 3022 1901 1.90 / 201.01 3 3
3 13 1469.44 22 14.50 2329 743 2.65 / 201.75 3 3
4 13 779.96 22 14.76 1407 457 3.10 / 202.20 3 3
5 13 206.16 22 15.03 613 203 3.30 / 202.41 3 3
6 8 0.12 165 15.11 300 748 4.05 / 203.16 3 3
Average= 4.06
(KJ/cycle)

Cycle 48 GMT 8/12/2018 14:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.32 22 15.21 2 1 0.00 / 194.91 3 3
2 7 2006.60 44 14.30 3033 1908 1.91 / 196.81 3 3
3 13 1596.80 22 14.45 2509 798 2.71 / 197.61 3 3
4 13 876.64 22 14.71 1540 498 3.21 / 198.11 3 3
5 13 280.68 22 14.99 725 239 3.44 / 198.35 3 3
6 8 0.00 165 15.11 302 753 4.20 / 199.10 3 3
Average= 4.06
(KJ/cycle)

Cycle 47 GMT 28/11/2018 14:30: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.00 22 15.21 1 0 0.00 / 190.72 3 3
2 7 2007.12 44 14.31 3024 1904 1.90 / 192.62 3 3
3 13 1593.20 22 14.45 2503 796 2.70 / 193.42 3 3
4 13 873.36 22 14.72 1534 497 3.20 / 193.91 3 3
5 13 282.64 22 14.99 735 242 3.44 / 194.15 3 3
6 8 0.08 165 15.12 301 751 4.19 / 194.91 3 3
Average= 4.06
(KJ/cycle)

Cycle 46 GMT 18/11/2018 14:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.60 22 15.21 2 1 0.00 / 186.61 3 3
2 7 2004.20 44 14.31 3018 1900 1.90 / 188.51 3 3
3 13 1456.04 22 14.50 2319 740 2.64 / 189.25 3 3
4 13 902.88 22 14.70 1585 513 3.15 / 189.76 3 3
5 13 174.56 22 15.06 576 191 3.34 / 189.95 3 3
6 8 0.20 165 15.12 305 761 4.11 / 190.72 3 3
Average= 4.06
(KJ/cycle)

Cycle 45 GMT 8/11/2018 14:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.76 22 15.22 2 1 0.00 / 182.41 3 3
2 7 2002.68 44 14.31 3019 1901 1.90 / 184.31 3 3
3 13 1599.12 22 14.46 2501 796 2.70 / 185.11 3 3
4 13 874.96 22 14.72 1548 501 3.20 / 185.61 3 3
5 13 288.68 22 15.00 736 243 3.44 / 185.85 3 3
6 8 -0.04 165 15.12 305 761 4.20 / 186.61 3 3
Average= 4.06
(KJ/cycle)

Cycle 44 GMT 29/10/2018 14:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.88 22 15.22 3 1 0.00 / 178.24 3 3
2 7 2004.68 45 14.32 3020 1946 1.95 / 180.19 3 3
3 13 1595.00 22 14.46 2504 797 2.74 / 180.98 3 3
4 13 862.36 22 14.73 1521 493 3.24 / 181.47 3 3
5 13 151.84 22 15.08 535 177 3.41 / 181.65 3 3
6 8 0.08 165 15.13 303 756 4.17 / 182.41 3 3
Average= 4.05
(KJ/cycle)

Cycle 43 GMT 19/10/2018 14:59: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.80 22 15.22 3 1 0.00 / 174.06 3 3
2 7 2004.60 44 14.32 3008 1895 1.90 / 175.96 3 3
3 13 1589.24 22 14.47 2489 792 2.69 / 176.75 3 3
4 13 1002.12 22 14.67 1720 555 3.24 / 177.31 3 3
5 13 149.28 22 15.09 528 175 3.42 / 177.48 3 3
6 8 0.00 165 15.13 303 756 4.18 / 178.24 3 3
Average= 4.05
(KJ/cycle)

Cycle 42 GMT 9/10/2018 15: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.68 22 15.22 3 1 0.00 / 169.87 3 3
2 7 2002.48 44 14.33 3007 1896 1.90 / 171.77 3 3
3 13 1589.52 22 14.47 2490 793 2.69 / 172.56 3 3
4 13 867.40 22 14.73 1541 499 3.19 / 173.06 3 3
5 13 270.28 22 15.01 716 236 3.43 / 173.30 3 3
6 8 0.32 165 15.13 307 766 4.19 / 174.06 3 3
Average= 4.05
(KJ/cycle)

Cycle 41 GMT 29/ 9/2018 15:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.64 21 15.23 3 1 0.00 / 165.69 3 3
2 7 2002.40 44 14.33 3021 1905 1.91 / 167.60 3 3
3 13 1578.04 22 14.47 2481 790 2.70 / 168.38 3 3
4 13 856.56 22 14.74 1511 490 3.19 / 168.87 3 3
5 13 258.60 22 15.02 694 229 3.41 / 169.10 3 3
6 8 0.16 165 15.13 307 766 4.18 / 169.87 3 3
Average= 4.04
(KJ/cycle)

Cycle 40 GMT 19/ 9/2018 15:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.24 21 15.23 2 1 0.00 / 161.57 3 3
2 7 2002.80 44 14.33 3014 1900 1.90 / 163.47 3 3
3 13 1578.96 22 14.48 2489 793 2.69 / 164.26 3 3
4 13 854.48 22 14.75 1512 491 3.18 / 164.75 3 3
5 13 150.76 22 15.10 534 177 3.36 / 164.93 3 3
6 8 0.08 165 15.14 304 759 4.12 / 165.69 3 3
Average= 4.04
(KJ/cycle)

Cycle 39 GMT 9/ 9/2018 15:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.84 22 15.23 3 1 0.00 / 157.41 3 3
2 7 2003.16 44 14.33 3030 1910 1.91 / 159.32 3 3
3 13 1583.48 22 14.49 2483 792 2.70 / 160.11 3 3
4 13 877.84 22 14.73 1553 503 3.21 / 160.62 3 3
5 13 165.84 22 15.09 558 185 3.39 / 160.80 3 3
6 8 0.12 165 15.14 307 767 4.16 / 161.57 3 3
Average= 4.04
(KJ/cycle)

Cycle 38 GMT 30/ 8/2018 15:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.48 21 15.23 3 1 0.00 / 153.27 3 3
2 7 2003.12 44 14.34 3009 1899 1.90 / 155.17 3 3
3 13 1576.04 22 14.49 2474 789 2.69 / 155.96 3 3
4 13 873.80 22 14.73 1550 502 3.19 / 156.46 3 3
5 13 161.56 22 15.09 557 185 3.38 / 156.65 3 3
6 8 0.04 165 15.14 306 764 4.14 / 157.41 3 3
Average= 4.04
(KJ/cycle)

Cycle 37 GMT 20/ 8/2018 15:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.12 22 15.23 2 1 0.00 / 149.14 3 3
2 7 2002.40 44 14.34 3015 1902 1.90 / 151.04 3 3
3 13 1590.56 22 14.48 2484 791 2.69 / 151.83 3 3
4 13 878.24 22 14.74 1548 502 3.20 / 152.33 3 3
5 13 154.84 22 15.10 540 179 3.38 / 152.51 3 3
6 8 0.16 165 15.15 303 757 4.13 / 153.27 3 3
Average= 4.03
(KJ/cycle)

Cycle 36 GMT 10/ 8/2018 15:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.36 22 15.23 3 1 0.00 / 144.93 3 3
2 7 2001.96 44 14.34 3030 1912 1.91 / 146.84 3 3
3 13 1591.68 22 14.48 2510 800 2.71 / 147.64 3 3
4 13 857.56 22 14.75 1518 493 3.20 / 148.13 3 3
5 13 262.16 22 15.03 703 232 3.44 / 148.36 3 3
6 8 0.00 165 15.14 309 772 4.21 / 149.14 3 3
Average= 4.03
(KJ/cycle)

Cycle 35 GMT 31/ 7/2018 16: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.92 22 15.24 2 1 0.00 / 140.68 3 3
2 7 2002.84 44 14.35 3028 1912 1.91 / 142.59 3 3
3 13 1587.72 22 14.50 2482 792 2.70 / 143.38 3 3
4 13 985.00 22 14.69 1700 549 3.25 / 143.93 3 3
5 13 240.60 22 15.05 675 223 3.48 / 144.16 3 3
6 8 0.00 165 15.14 308 769 4.25 / 144.93 3 3
Average= 4.03
(KJ/cycle)

Cycle 34 GMT 21/ 7/2018 16:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.92 22 15.24 2 1 0.00 / 136.47 3 3
2 7 2006.32 44 14.35 3034 1916 1.92 / 138.38 3 3
3 13 1591.68 22 14.50 2497 797 2.71 / 139.18 3 3
4 13 860.84 22 14.76 1532 497 3.21 / 139.67 3 3
5 13 267.68 22 15.03 713 236 3.45 / 139.91 3 3
6 8 0.24 165 15.15 308 770 4.22 / 140.68 3 3
Average= 4.02
(KJ/cycle)

Cycle 33 GMT 11/ 7/2018 16:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.16 22 15.25 2 1 0.00 / 132.40 3 3
2 7 2003.80 44 14.35 3016 1904 1.90 / 134.31 3 3
3 13 1454.84 22 14.55 2320 743 2.65 / 135.05 3 3
4 13 749.16 22 14.81 1369 446 3.09 / 135.49 3 3
5 13 192.36 22 15.08 602 200 3.29 / 135.69 3 3
6 8 0.20 165 15.15 308 770 4.06 / 136.46 3 3
Average= 4.01
(KJ/cycle)

Cycle 32 GMT 1/ 7/2018 16:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.20 23 15.25 2 1 0.00 / 128.26 3 3
2 7 2004.44 44 14.36 3015 1905 1.91 / 130.16 3 3
3 13 1592.64 22 14.50 2508 800 2.71 / 130.96 3 3
4 13 862.00 22 14.76 1528 496 3.20 / 131.46 3 3
5 13 150.92 22 15.11 539 179 3.38 / 131.64 3 3
6 8 -0.12 165 15.16 306 765 4.15 / 132.40 3 3
Average= 4.01
(KJ/cycle)

Cycle 31 GMT 21/ 6/2018 16:25: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 22 15.25 2 1 0.00 / 124.11 3 3
2 7 2004.48 44 14.37 3026 1913 1.91 / 126.02 3 3
3 13 1586.52 22 14.51 2495 796 2.71 / 126.82 3 3
4 13 870.56 22 14.76 1539 500 3.21 / 127.32 3 3
5 13 155.80 22 15.12 543 181 3.39 / 127.50 3 3
6 8 0.08 165 15.17 303 758 4.15 / 128.25 3 3
Average= 4.01
(KJ/cycle)

Cycle 30 GMT 11/ 6/2018 16:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.52 22 15.25 2 1 0.00 / 119.99 3 3
2 7 2004.40 44 14.37 3017 1908 1.91 / 121.90 3 3
3 13 1467.72 22 14.56 2331 747 2.65 / 122.65 3 3
4 13 893.48 22 14.76 1564 508 3.16 / 123.15 3 3
5 13 176.04 22 15.10 580 193 3.36 / 123.35 3 3
6 8 0.12 165 15.16 303 758 4.11 / 124.11 3 3
Average= 4.00
(KJ/cycle)

Cycle 29 GMT 1/ 6/2018 16:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.32 23 15.25 2 1 0.00 / 115.76 3 3
2 7 2004.28 44 14.37 3032 1917 1.92 / 117.67 3 3
3 13 1720.72 22 14.47 2680 853 2.77 / 118.53 3 3
4 13 839.56 22 14.78 1501 488 3.26 / 119.01 3 3
5 13 250.04 22 15.06 688 228 3.49 / 119.24 3 3
6 8 0.16 165 15.16 300 750 4.24 / 119.99 3 3
Average= 4.00
(KJ/cycle)

Cycle 28 GMT 22/ 5/2018 16: 9: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.88 23 15.26 2 1 0.00 / 111.68 3 3
2 7 2005.64 44 14.37 3037 1920 1.92 / 113.60 3 3
3 13 1467.44 22 14.57 2336 749 2.67 / 114.35 3 3
4 13 777.48 22 14.81 1412 460 3.13 / 114.81 3 3
5 13 200.60 22 15.09 613 204 3.33 / 115.01 3 3
6 8 0.08 165 15.17 298 746 4.08 / 115.75 3 3
Average= 3.99
(KJ/cycle)

Cycle 27 GMT 12/ 5/2018 16: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.04 25 15.27 2 1 0.00 / 107.56 3 3
2 3 945.88 -1 15.52 0 0 0.00 / 107.56 3 3
3 3 970.20 -1 15.54 0 0 0.00 / 107.56 3 3
4 7 2002.36 44 14.38 3034 1920 1.92 / 109.48 3 3
5 13 1466.00 22 14.56 2336 748 2.67 / 110.23 3 3
6 13 883.76 22 14.76 1562 507 3.18 / 110.73 3 3
7 13 160.00 22 15.12 548 182 3.36 / 110.91 3 3
8 8 0.04 165 15.17 304 761 4.12 / 111.68 3 3
Average= 3.99
(KJ/cycle)

Cycle 26 GMT 2/ 5/2018 16: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.40 25 15.26 3 1 0.00 / 103.40 3 3
2 7 2003.00 44 14.38 3031 1918 1.92 / 105.32 3 3
3 13 1594.44 22 14.53 2509 802 2.72 / 106.12 3 3
4 13 860.44 22 14.78 1523 495 3.22 / 106.62 3 3
5 13 148.00 22 15.13 535 178 3.39 / 106.80 3 3
6 8 0.00 165 15.18 303 759 4.15 / 107.56 3 3
Average= 3.98
(KJ/cycle)

Cycle 25 GMT 22/ 4/2018 16: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.24 25 15.28 2 1 0.00 / 99.15 3 3
2 7 2004.84 44 14.38 3031 1918 1.92 / 101.06 3 3
3 13 1592.68 22 14.53 2510 802 2.72 / 101.87 3 3
4 13 865.88 22 14.78 1519 494 3.21 / 102.36 3 3
5 13 150.64 22 15.13 537 179 3.39 / 102.54 3 3
6 13 15.44 22 15.20 330 110 3.50 / 102.65 3 3
7 8 -0.04 165 15.17 301 753 4.26 / 103.40 3 3
Average= 3.98
(KJ/cycle)

Cycle 24 GMT 12/ 4/2018 16: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.44 24 15.28 2 1 0.00 / 94.93 3 3
2 3 1020.76 1 15.53 4 0 0.00 / 94.93 3 3
3 7 2004.04 44 14.39 3027 1917 1.92 / 96.84 3 3
4 13 1585.40 22 14.54 2490 797 2.71 / 97.64 3 3
5 13 987.68 22 14.73 1697 550 3.26 / 98.19 3 3
6 13 231.08 22 15.09 654 217 3.48 / 98.41 3 3
7 8 0.04 165 15.19 295 739 4.22 / 99.15 3 3
Average= 3.97
(KJ/cycle)

Cycle 23 GMT 2/ 4/2018 16: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.00 25 15.28 3 1 0.00 / 90.77 3 3
2 3 972.88 -1 15.55 0 0 0.00 / 90.77 3 3
3 7 2004.28 44 14.39 3034 1921 1.92 / 92.70 3 3
4 13 1579.48 22 14.54 2484 795 2.72 / 93.49 3 3
5 13 870.52 22 14.79 1533 499 3.22 / 93.99 3 3
6 13 154.12 22 15.14 540 180 3.40 / 94.17 3 3
7 8 0.04 165 15.19 302 757 4.15 / 94.93 3 3
Average= 3.96
(KJ/cycle)

Cycle 22 GMT 23/ 3/2018 16: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.48 25 15.28 2 1 0.00 / 86.66 3 3
2 7 2003.60 44 14.40 3030 1920 1.92 / 88.58 3 3
3 13 1461.56 22 14.59 2335 749 2.67 / 89.33 3 3
4 13 882.16 22 14.78 1558 507 3.18 / 89.84 3 3
5 13 150.84 22 15.14 543 181 3.36 / 90.02 3 3
6 8 0.12 165 15.19 302 757 4.11 / 90.77 3 3
Average= 3.95
(KJ/cycle)

Cycle 21 GMT 13/ 3/2018 15:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.00 23 15.28 2 1 0.00 / 82.42 3 3
2 10 1008.12 3 15.49 5 0 0.00 / 82.42 3 3
3 7 2004.92 44 14.40 3031 1920 1.92 / 84.34 3 3
4 13 1463.76 22 14.59 2328 747 2.67 / 85.09 3 3
5 13 886.76 22 14.79 1562 508 3.18 / 85.60 3 3
6 13 152.08 22 15.15 545 182 3.36 / 85.78 3 3
7 13 31.00 22 15.20 361 121 3.48 / 85.90 3 3
8 8 0.08 165 15.18 302 756 4.24 / 86.66 3 3
Average= 3.94
(KJ/cycle)

Cycle 20 GMT 3/ 3/2018 15:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.60 25 15.29 2 1 0.00 / 78.11 3 3
2 3 941.68 -1 15.54 0 0 0.00 / 78.11 3 3
3 3 963.88 -1 15.56 0 0 0.00 / 78.11 3 3
4 7 2002.00 44 14.41 3030 1921 1.92 / 80.03 3 3
5 13 1585.92 22 14.55 2499 800 2.72 / 80.83 3 3
6 13 855.88 22 14.80 1518 494 3.22 / 81.32 3 3
7 13 249.72 22 15.08 691 229 3.45 / 81.55 3 3
8 13 20.92 22 15.21 343 115 3.56 / 81.67 3 3
9 8 0.08 165 15.19 301 754 4.31 / 82.42 3 3
Average= 3.92
(KJ/cycle)

Cycle 19 GMT 21/ 2/2018 15:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.88 25 15.29 2 1 0.00 / 73.92 3 3
2 7 2002.96 45 14.42 3029 1966 1.97 / 75.88 3 3
3 13 1577.32 22 14.56 2497 800 2.77 / 76.68 3 3
4 13 847.44 22 14.81 1506 491 3.26 / 77.17 3 3
5 13 131.84 22 15.16 512 171 3.43 / 77.34 3 3
6 8 -0.12 165 15.20 305 765 4.19 / 78.11 3 3
Average= 3.91
(KJ/cycle)

Cycle 18 GMT 11/ 2/2018 15:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.44 24 15.29 2 1 0.00 / 69.66 3 3
2 3 1044.84 1 15.55 3 0 0.00 / 69.66 3 3
3 7 2003.20 44 14.43 3036 1928 1.93 / 71.59 3 3
4 13 1578.68 22 14.57 2500 801 2.73 / 72.39 3 3
5 13 979.12 22 14.76 1696 551 3.28 / 72.94 3 3
6 13 213.28 22 15.12 638 212 3.49 / 73.15 3 3
7 8 0.08 165 15.20 305 765 4.26 / 73.92 3 3
Average= 3.89
(KJ/cycle)

Cycle 17 GMT 1/ 2/2018 15:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.28 24 15.30 3 1 0.00 / 65.49 3 3
2 7 2001.96 44 14.43 3037 1928 1.93 / 67.42 3 3
3 13 1580.12 22 14.56 2492 798 2.73 / 68.22 3 3
4 13 852.64 22 14.82 1520 496 3.22 / 68.71 3 3
5 13 137.60 22 15.17 520 174 3.40 / 68.89 3 3
6 8 0.20 165 15.20 308 772 4.17 / 69.66 3 3
Average= 3.87
(KJ/cycle)

Cycle 16 GMT 22/ 1/2018 15:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.60 25 15.30 2 1 0.00 / 61.18 3 3
2 3 969.44 -1 15.56 0 0 0.00 / 61.18 3 3
3 7 2003.88 44 14.43 3027 1922 1.92 / 63.10 3 3
4 13 1726.68 22 14.53 2680 857 2.78 / 63.96 3 3
5 13 962.28 22 14.77 1672 543 3.32 / 64.50 3 3
6 13 208.56 22 15.12 630 210 3.53 / 64.71 3 3
7 8 0.00 165 15.21 309 775 4.31 / 65.49 3 3
Average= 3.85
(KJ/cycle)

Cycle 15 GMT 12/ 1/2018 15: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.20 25 15.30 3 1 0.00 / 56.96 3 3
2 7 2004.16 44 14.44 3035 1928 1.93 / 58.89 3 3
3 13 1580.08 22 14.58 2487 798 2.73 / 59.69 3 3
4 13 847.88 22 14.83 1511 493 3.22 / 60.18 3 3
5 13 238.96 22 15.11 675 224 3.44 / 60.41 3 3
6 8 0.00 165 15.21 309 775 4.22 / 61.18 3 3
Average= 3.82
(KJ/cycle)

Cycle 14 GMT 2/ 1/2018 15: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.64 25 15.30 3 1 0.00 / 52.74 3 3
2 7 2004.00 44 14.44 3041 1932 1.93 / 54.67 3 3
3 13 1578.80 22 14.58 2490 799 2.73 / 55.47 3 3
4 13 845.76 22 14.83 1510 493 3.22 / 55.96 3 3
5 13 239.12 22 15.11 676 225 3.45 / 56.18 3 3
6 8 0.04 165 15.21 310 778 4.23 / 56.96 3 3
Average= 3.80
(KJ/cycle)

Cycle 13 GMT 23/12/2017 15: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.88 23 15.30 2 1 0.00 / 48.63 3 3
2 3 1079.56 2 15.57 4 0 0.00 / 48.63 3 3
3 7 2003.32 44 14.46 3017 1920 1.92 / 50.55 3 3
4 13 1467.48 22 14.63 2340 753 2.67 / 51.30 3 3
5 13 763.12 22 14.87 1393 456 3.13 / 51.76 3 3
6 13 184.28 22 15.15 596 199 3.33 / 51.95 3 3
7 8 0.12 165 15.21 311 781 4.11 / 52.73 3 3
Average= 3.77
(KJ/cycle)

Cycle 12 GMT 13/12/2017 14:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.00 24 15.31 3 1 0.00 / 44.43 3 3
2 3 963.40 -1 15.57 0 0 0.00 / 44.43 3 3
3 7 2005.56 44 14.45 3039 1932 1.93 / 46.36 3 3
4 13 1449.24 22 14.64 2309 744 2.68 / 47.11 3 3
5 13 865.24 22 14.83 1538 502 3.18 / 47.61 3 3
6 13 258.04 22 15.11 703 234 3.41 / 47.84 3 3
7 8 0.00 165 15.21 312 783 4.20 / 48.63 3 3
Average= 3.74
(KJ/cycle)

Cycle 11 GMT 3/12/2017 14:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.96 25 15.31 3 1 0.00 / 40.31 3 3
2 7 2003.04 44 14.47 3018 1922 1.92 / 42.23 3 3
3 13 1445.76 22 14.64 2317 746 2.67 / 42.98 3 3
4 13 869.40 22 14.83 1536 501 3.17 / 43.48 3 3
5 13 144.68 22 15.19 529 177 3.35 / 43.65 3 3
6 8 0.00 165 15.22 309 776 4.12 / 44.43 3 3
Average= 3.70
(KJ/cycle)

Cycle 10 GMT 23/11/2017 14: 5: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.56 25 15.31 2 1 0.00 / 36.10 3 3
2 7 2004.40 45 14.47 3029 1972 1.97 / 38.07 3 3
3 13 1576.64 22 14.61 2473 795 2.77 / 38.87 3 3
4 13 843.96 22 14.85 1505 492 3.26 / 39.36 3 3
5 13 135.56 22 15.19 513 171 3.43 / 39.53 3 3
6 8 0.20 165 15.22 310 779 4.21 / 40.31 3 3
Average= 3.66
(KJ/cycle)

Cycle 9 GMT 13/11/2017 13:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.40 25 15.31 3 1 0.00 / 32.02 3 3
2 7 2002.60 44 14.48 3019 1923 1.92 / 33.94 3 3
3 13 1450.24 22 14.65 2303 742 2.67 / 34.68 3 3
4 13 743.40 22 14.90 1366 448 3.11 / 35.13 3 3
5 13 165.72 22 15.17 563 188 3.30 / 35.32 3 3
6 8 0.16 165 15.22 310 779 4.08 / 36.10 3 3
Average= 3.61
(KJ/cycle)

Cycle 8 GMT 3/11/2017 13:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.28 25 15.31 2 1 0.00 / 27.81 3 3
2 7 2002.36 44 14.48 3017 1922 1.92 / 29.73 3 3
3 13 1574.68 22 14.62 2482 798 2.72 / 30.53 3 3
4 13 840.64 22 14.86 1497 489 3.21 / 31.02 3 3
5 13 232.04 22 15.13 657 219 3.43 / 31.24 3 3
6 8 0.04 165 15.22 310 779 4.21 / 32.02 3 3
Average= 3.56
(KJ/cycle)

Cycle 7 GMT 24/10/2017 13:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.24 24 15.31 3 1 0.00 / 23.64 3 3
2 3 1026.40 1 15.57 4 0 0.00 / 23.64 3 3
3 7 2001.48 44 14.48 3030 1930 1.93 / 25.57 3 3
4 13 1571.20 22 14.63 2465 793 2.73 / 26.36 3 3
5 13 842.92 22 14.86 1505 492 3.22 / 26.86 3 3
6 13 131.76 22 15.20 509 170 3.39 / 27.03 3 3
7 8 0.08 165 15.22 312 784 4.17 / 27.81 3 3
Average= 3.48
(KJ/cycle)

Cycle 6 GMT 14/10/2017 13: 7:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.52 12 15.31 3 1 0.00 / 19.51 3 3
2 10 1038.20 6 15.49 4 0 0.00 / 19.51 3 3
3 10 1085.80 4 15.49 5 0 0.00 / 19.51 3 3
4 3 1116.00 3 15.57 5 0 0.00 / 19.51 3 3
5 3 1024.68 1 15.59 5 0 0.00 / 19.51 3 3
6 7 2004.00 44 14.48 3033 1932 1.93 / 21.44 3 3
7 13 1572.60 22 14.63 2470 795 2.73 / 22.24 3 3
8 13 727.96 22 14.91 1338 439 3.17 / 22.68 3 3
9 13 150.20 22 15.18 539 180 3.35 / 22.86 3 3
10 8 0.20 165 15.22 311 781 4.13 / 23.64 3 3
Average= 3.38
(KJ/cycle)

Cycle 5 GMT 4/10/2017 12:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.36 24 15.34 4 1 0.00 / 15.37 3 3
2 3 772.52 -4 15.59 0 0 0.00 / 15.37 3 3
3 3 807.92 -4 15.61 0 0 0.00 / 15.37 3 3
4 7 2002.24 44 14.50 2995 1911 1.91 / 17.28 3 3
5 13 1570.24 22 14.63 2469 795 2.71 / 18.08 3 3
6 13 838.36 22 14.87 1489 487 3.19 / 18.56 3 3
7 13 126.08 22 15.21 490 164 3.36 / 18.73 3 3
8 8 -0.12 165 15.23 311 782 4.14 / 19.51 3 3
Average= 3.25
(KJ/cycle)

Cycle 4 GMT 24/ 9/2017 11:58: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.44 24 15.32 3 1 0.00 / 11.99 3 3
2 7 1506.92 44 14.73 2346 1520 1.52 / 13.51 3 3
3 13 1255.92 22 14.81 2009 655 2.18 / 14.16 3 3
4 13 675.52 22 14.98 1274 420 2.60 / 14.58 3 3
5 8 0.16 165 15.26 312 786 3.38 / 15.37 3 3
Average= 3.07
(KJ/cycle)

Cycle 3 GMT 23/ 9/2017 12:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.88 24 15.31 3 1 0.00 / 8.49 3 3
2 7 1512.76 44 14.73 2339 1516 1.52 / 10.00 3 3
3 13 1259.80 22 14.79 2046 666 2.18 / 10.67 3 3
4 13 561.92 22 15.02 1104 365 2.55 / 11.04 3 3
5 13 123.28 22 15.22 488 163 2.71 / 11.20 3 3
6 8 0.00 165 15.24 314 790 3.50 / 11.99 3 3
Average= 3.00
(KJ/cycle)

Cycle 2 GMT 22/ 9/2017 13:14:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.72 24 15.34 3 1 0.00 / 4.51 3 3
2 7 1506.00 75 14.65 2331 2561 2.56 / 7.07 3 3
3 13 291.84 25 15.12 748 283 2.85 / 7.35 3 3
4 8 0.04 240 15.22 311 1136 3.98 / 8.49 3 3
Average= 2.83
(KJ/cycle)

Cycle 1 GMT 21/ 9/2017 14: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.00 24 15.51 4 1 0.00 / 1.54 3 3
2 3 946.40 -1 15.60 0 0 0.00 / 1.54 3 3
3 3 966.00 -1 15.61 0 0 0.00 / 1.54 3 3
4 7 979.84 74 14.88 1627 1792 1.79 / 3.33 3 3
5 8 0.12 240 15.26 321 1176 2.97 / 4.51 3 3
Average= 2.25
(KJ/cycle)

Cycle 0 GMT 21/ 9/2017 2:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 88.08 24 15.68 4 2 0.00 / 0.00 3 3
2 7 98.04 74 15.55 427 491 0.49 / 0.49 3 3
3 8 0.32 240 15.50 281 1045 1.54 / 1.54 3 10
Average= 1.54
(KJ/cycle)