SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.28 | 43 | 14.73 | 416 | 263 | 0.26 / 160.36 | 2 | 3 |
2 | 3 | 1023.36 | 1 | 14.80 | 1664 | 25 | 0.29 / 160.39 | 2 | 5 |
3 | 8 | 2005.80 | 58 | 14.47 | 2866 | 2405 | 2.69 / 162.79 | 2 | 4 |
4 | 14 | 1550.36 | 16 | 14.53 | 2318 | 539 | 3.23 / 163.33 | 2 | 7 |
5 | 14 | 1096.84 | 16 | 14.60 | 1744 | 407 | 3.64 / 163.74 | 2 | 7 |
6 | 14 | 831.72 | 16 | 14.64 | 1399 | 328 | 3.97 / 164.07 | 2 | 9 |
7 | 14 | 589.72 | 16 | 14.70 | 1088 | 256 | 4.22 / 164.32 | 2 | 9 |
8 | 14 | 466.48 | 16 | 14.71 | 924 | 217 | 4.44 / 164.54 | 2 | 9 |
9 | 14 | 216.84 | 16 | 14.75 | 579 | 137 | 4.58 / 164.68 | 2 | 9 |
10 | 14 | 150.80 | 16 | 14.77 | 483 | 114 | 4.69 / 164.79 | 2 | 9 |
11 | 14 | 79.96 | 16 | 14.76 | 380 | 90 | 4.78 / 164.88 | 2 | 8 |
12 | 14 | 48.08 | 16 | 14.75 | 335 | 79 | 4.86 / 164.96 | 2 | 8 |
13 | 9 | 0.20 | 165 | 14.77 | 260 | 634 | 5.49 / 165.59 | 2 | 58 |
14 | 15 | 0.04 | 55 | 14.76 | 192 | 156 | 5.65 / 165.75 | 12 | 247 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.32 | 43 | 14.70 | 399 | 252 | 0.25 / 154.73 | 3 | 3 |
2 | 3 | 1016.28 | 1 | 14.83 | 1678 | 25 | 0.28 / 154.76 | 2 | 4 |
3 | 8 | 2006.44 | 59 | 14.46 | 2847 | 2429 | 2.71 / 157.19 | 2 | 5 |
4 | 14 | 1391.12 | 16 | 14.56 | 2110 | 492 | 3.20 / 157.68 | 2 | 6 |
5 | 14 | 1187.24 | 16 | 14.57 | 1868 | 435 | 3.63 / 158.11 | 2 | 8 |
6 | 14 | 872.52 | 16 | 14.63 | 1450 | 339 | 3.97 / 158.45 | 2 | 9 |
7 | 14 | 587.28 | 16 | 14.69 | 1083 | 255 | 4.23 / 158.71 | 2 | 9 |
8 | 14 | 387.16 | 16 | 14.73 | 817 | 193 | 4.42 / 158.90 | 2 | 10 |
9 | 14 | 197.08 | 16 | 14.76 | 552 | 130 | 4.55 / 159.03 | 2 | 9 |
10 | 14 | 127.64 | 16 | 14.77 | 453 | 107 | 4.66 / 159.14 | 2 | 9 |
11 | 14 | 69.96 | 16 | 14.78 | 365 | 86 | 4.74 / 159.22 | 2 | 8 |
12 | 14 | 40.56 | 16 | 14.76 | 326 | 77 | 4.82 / 159.30 | 2 | 8 |
13 | 9 | -0.04 | 165 | 14.77 | 265 | 646 | 5.47 / 159.95 | 2 | 92 |
14 | 15 | 0.00 | 55 | 14.77 | 189 | 154 | 5.62 / 160.10 | 14 | 247 |
Average= | 4.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.12 | 43 | 14.73 | 402 | 255 | 0.25 / 149.10 | 2 | 3 |
2 | 3 | 1018.24 | 1 | 14.81 | 1679 | 25 | 0.28 / 149.12 | 2 | 4 |
3 | 3 | 1017.84 | 1 | 14.82 | 1662 | 25 | 0.30 / 149.15 | 2 | 4 |
4 | 8 | 2005.44 | 59 | 14.50 | 2856 | 2443 | 2.75 / 151.59 | 2 | 4 |
5 | 14 | 1343.28 | 16 | 14.61 | 2046 | 478 | 3.23 / 152.07 | 2 | 7 |
6 | 14 | 1185.48 | 16 | 14.60 | 1863 | 435 | 3.66 / 152.50 | 2 | 7 |
7 | 14 | 809.40 | 16 | 14.68 | 1373 | 322 | 3.98 / 152.83 | 2 | 8 |
8 | 14 | 547.92 | 16 | 14.73 | 1031 | 243 | 4.23 / 153.07 | 2 | 10 |
9 | 14 | 424.80 | 16 | 14.75 | 868 | 205 | 4.43 / 153.27 | 2 | 10 |
10 | 14 | 217.52 | 16 | 14.78 | 586 | 139 | 4.57 / 153.41 | 2 | 10 |
11 | 14 | 144.96 | 16 | 14.78 | 476 | 113 | 4.68 / 153.52 | 2 | 9 |
12 | 14 | 77.20 | 16 | 14.80 | 379 | 90 | 4.77 / 153.61 | 2 | 8 |
13 | 14 | 21.56 | 16 | 14.79 | 297 | 70 | 4.84 / 153.68 | 2 | 8 |
14 | 9 | 0.08 | 163 | 14.78 | 263 | 634 | 5.48 / 154.32 | 2 | 58 |
15 | 15 | 0.08 | 57 | 14.78 | 191 | 161 | 5.64 / 154.48 | 14 | 247 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.88 | 43 | 14.73 | 411 | 260 | 0.26 / 143.58 | 3 | 3 |
2 | 3 | 1021.00 | 1 | 14.81 | 1676 | 25 | 0.29 / 143.61 | 2 | 4 |
3 | 8 | 2008.68 | 58 | 14.49 | 2860 | 2404 | 2.69 / 146.01 | 2 | 5 |
4 | 14 | 1484.76 | 16 | 14.56 | 2231 | 520 | 3.21 / 146.53 | 2 | 6 |
5 | 14 | 1073.40 | 16 | 14.64 | 1720 | 403 | 3.61 / 146.93 | 2 | 8 |
6 | 14 | 834.80 | 16 | 14.67 | 1407 | 330 | 3.94 / 147.26 | 2 | 9 |
7 | 14 | 593.16 | 16 | 14.72 | 1089 | 256 | 4.20 / 147.52 | 2 | 9 |
8 | 14 | 386.16 | 16 | 14.75 | 815 | 192 | 4.39 / 147.71 | 2 | 10 |
9 | 14 | 190.24 | 16 | 14.77 | 544 | 129 | 4.52 / 147.84 | 2 | 9 |
10 | 14 | 124.04 | 16 | 14.78 | 443 | 105 | 4.62 / 147.95 | 2 | 9 |
11 | 14 | 56.52 | 16 | 14.78 | 347 | 82 | 4.71 / 148.03 | 2 | 8 |
12 | 9 | 0.08 | 178 | 14.78 | 262 | 689 | 5.40 / 148.72 | 2 | 53 |
13 | 15 | -0.12 | 42 | 14.78 | 201 | 125 | 5.52 / 148.84 | 13 | 247 |
Average= | 4.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.16 | 43 | 14.72 | 403 | 255 | 0.26 / 138.05 | 2 | 3 |
2 | 11 | 1006.56 | 2 | 14.81 | 1652 | 49 | 0.30 / 138.10 | 2 | 3 |
3 | 8 | 2005.04 | 58 | 14.49 | 2857 | 2401 | 2.71 / 140.50 | 2 | 5 |
4 | 14 | 1401.52 | 16 | 14.58 | 2122 | 495 | 3.20 / 141.00 | 2 | 6 |
5 | 14 | 1242.60 | 16 | 14.59 | 1935 | 452 | 3.65 / 141.45 | 2 | 7 |
6 | 14 | 783.76 | 16 | 14.67 | 1342 | 315 | 3.97 / 141.76 | 2 | 9 |
7 | 14 | 547.92 | 16 | 14.72 | 1032 | 243 | 4.21 / 142.01 | 2 | 10 |
8 | 14 | 314.40 | 16 | 14.76 | 719 | 170 | 4.38 / 142.18 | 2 | 10 |
9 | 14 | 206.76 | 16 | 14.78 | 567 | 134 | 4.51 / 142.31 | 2 | 9 |
10 | 14 | 135.28 | 16 | 14.79 | 462 | 109 | 4.62 / 142.42 | 2 | 9 |
11 | 14 | 61.72 | 16 | 14.80 | 356 | 84 | 4.71 / 142.50 | 2 | 8 |
12 | 9 | 0.52 | 178 | 14.78 | 264 | 695 | 5.40 / 143.20 | 2 | 57 |
13 | 15 | 0.04 | 42 | 14.78 | 201 | 125 | 5.53 / 143.32 | 12 | 247 |
Average= | 4.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.24 | 43 | 14.76 | 400 | 254 | 0.25 / 132.39 | 2 | 3 |
2 | 11 | 1004.96 | 2 | 14.83 | 1672 | 50 | 0.30 / 132.44 | 2 | 3 |
3 | 3 | 970.40 | -1 | 15.21 | 4 | 0 | 0.05 / 132.44 | 2 | 3 |
4 | 8 | 2005.64 | 58 | 14.50 | 2864 | 2409 | 2.71 / 134.85 | 2 | 5 |
5 | 14 | 1389.32 | 16 | 14.58 | 2113 | 493 | 3.21 / 135.34 | 2 | 7 |
6 | 14 | 1106.16 | 16 | 14.62 | 1761 | 412 | 3.62 / 135.76 | 2 | 8 |
7 | 14 | 908.56 | 16 | 14.65 | 1508 | 353 | 3.97 / 136.11 | 2 | 8 |
8 | 14 | 619.92 | 16 | 14.71 | 1125 | 265 | 4.24 / 136.37 | 2 | 10 |
9 | 14 | 410.88 | 16 | 14.73 | 849 | 200 | 4.44 / 136.57 | 2 | 10 |
10 | 14 | 241.64 | 16 | 14.77 | 621 | 147 | 4.58 / 136.72 | 2 | 10 |
11 | 14 | 128.12 | 16 | 14.78 | 452 | 107 | 4.69 / 136.83 | 2 | 9 |
12 | 14 | 66.24 | 16 | 14.80 | 365 | 86 | 4.78 / 136.91 | 2 | 8 |
13 | 14 | 38.20 | 16 | 14.79 | 325 | 77 | 4.85 / 136.99 | 2 | 9 |
14 | 9 | 0.12 | 165 | 14.78 | 266 | 649 | 5.50 / 137.64 | 2 | 89 |
15 | 15 | -0.12 | 55 | 14.78 | 192 | 156 | 5.66 / 137.80 | 14 | 247 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.68 | 43 | 14.77 | 419 | 266 | 0.27 / 126.83 | 2 | 3 |
2 | 3 | 1018.80 | 1 | 14.84 | 1671 | 25 | 0.29 / 126.85 | 2 | 3 |
3 | 8 | 2007.52 | 58 | 14.53 | 2874 | 2422 | 2.71 / 129.28 | 2 | 5 |
4 | 14 | 1308.00 | 16 | 14.64 | 2016 | 472 | 3.19 / 129.75 | 2 | 6 |
5 | 14 | 1110.12 | 16 | 14.65 | 1771 | 415 | 3.60 / 130.16 | 2 | 8 |
6 | 14 | 787.40 | 16 | 14.71 | 1343 | 316 | 3.92 / 130.48 | 2 | 9 |
7 | 14 | 518.48 | 16 | 14.77 | 996 | 235 | 4.15 / 130.72 | 2 | 9 |
8 | 14 | 402.36 | 16 | 14.78 | 842 | 199 | 4.35 / 130.91 | 2 | 10 |
9 | 14 | 200.60 | 16 | 14.83 | 561 | 133 | 4.48 / 131.05 | 2 | 9 |
10 | 14 | 133.92 | 16 | 14.82 | 464 | 110 | 4.59 / 131.16 | 2 | 9 |
11 | 14 | 100.48 | 16 | 14.82 | 419 | 99 | 4.69 / 131.26 | 2 | 9 |
12 | 14 | 31.20 | 16 | 14.80 | 315 | 75 | 4.77 / 131.33 | 2 | 8 |
13 | 9 | 0.08 | 163 | 14.81 | 267 | 645 | 5.41 / 131.98 | 2 | 63 |
14 | 15 | 0.08 | 57 | 14.82 | 193 | 163 | 5.58 / 132.14 | 15 | 247 |
Average= | 4.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.28 | 43 | 14.77 | 410 | 260 | 0.26 / 121.16 | 2 | 3 |
2 | 3 | 1020.40 | 1 | 14.86 | 1672 | 25 | 0.29 / 121.18 | 2 | 5 |
3 | 8 | 2009.12 | 58 | 14.52 | 2870 | 2417 | 2.70 / 123.60 | 2 | 4 |
4 | 14 | 1394.12 | 16 | 14.62 | 2125 | 497 | 3.20 / 124.10 | 2 | 7 |
5 | 14 | 1151.72 | 16 | 14.64 | 1825 | 427 | 3.63 / 124.52 | 2 | 8 |
6 | 14 | 866.88 | 16 | 14.68 | 1454 | 342 | 3.97 / 124.87 | 2 | 8 |
7 | 14 | 556.20 | 16 | 14.75 | 1045 | 247 | 4.21 / 125.11 | 2 | 9 |
8 | 14 | 404.68 | 16 | 14.77 | 845 | 200 | 4.41 / 125.31 | 2 | 10 |
9 | 14 | 279.20 | 16 | 14.79 | 674 | 159 | 4.57 / 125.47 | 2 | 10 |
10 | 14 | 126.64 | 16 | 14.81 | 453 | 107 | 4.68 / 125.58 | 2 | 9 |
11 | 14 | 94.04 | 16 | 14.81 | 416 | 99 | 4.78 / 125.68 | 2 | 9 |
12 | 14 | 29.52 | 16 | 14.81 | 317 | 75 | 4.86 / 125.75 | 2 | 8 |
13 | 9 | 0.08 | 163 | 14.80 | 268 | 647 | 5.50 / 126.40 | 2 | 56 |
14 | 15 | -0.04 | 57 | 14.80 | 194 | 164 | 5.67 / 126.56 | 13 | 247 |
Average= | 3.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.76 | 43 | 14.75 | 411 | 261 | 0.26 / 115.52 | 2 | 3 |
2 | 11 | 1006.48 | 2 | 14.80 | 1649 | 49 | 0.31 / 115.57 | 2 | 4 |
3 | 8 | 2006.52 | 59 | 14.52 | 2861 | 2451 | 2.76 / 118.02 | 2 | 5 |
4 | 14 | 1467.00 | 16 | 14.60 | 2229 | 521 | 3.28 / 118.54 | 2 | 6 |
5 | 14 | 1149.16 | 16 | 14.64 | 1817 | 426 | 3.71 / 118.97 | 2 | 7 |
6 | 14 | 906.72 | 16 | 14.67 | 1505 | 353 | 4.06 / 119.32 | 2 | 9 |
7 | 14 | 553.08 | 16 | 14.74 | 1044 | 246 | 4.31 / 119.57 | 2 | 9 |
8 | 14 | 362.24 | 16 | 14.78 | 784 | 185 | 4.49 / 119.75 | 2 | 10 |
9 | 14 | 215.48 | 16 | 14.80 | 578 | 137 | 4.63 / 119.89 | 2 | 9 |
10 | 14 | 146.08 | 16 | 14.80 | 472 | 112 | 4.74 / 120.00 | 2 | 8 |
11 | 14 | 74.36 | 16 | 14.81 | 367 | 87 | 4.83 / 120.09 | 2 | 8 |
12 | 9 | 0.04 | 178 | 14.82 | 260 | 686 | 5.51 / 120.78 | 2 | 54 |
13 | 15 | -0.08 | 42 | 14.81 | 196 | 122 | 5.64 / 120.90 | 13 | 247 |
Average= | 3.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.52 | 43 | 14.73 | 416 | 263 | 0.26 / 109.91 | 3 | 3 |
2 | 8 | 2004.64 | 58 | 14.53 | 2864 | 2414 | 2.68 / 112.32 | 2 | 6 |
3 | 14 | 1431.04 | 16 | 14.62 | 2178 | 509 | 3.19 / 112.83 | 2 | 7 |
4 | 14 | 1114.96 | 16 | 14.66 | 1774 | 416 | 3.60 / 113.25 | 2 | 7 |
5 | 14 | 914.12 | 16 | 14.69 | 1515 | 356 | 3.96 / 113.60 | 2 | 9 |
6 | 14 | 586.44 | 16 | 14.75 | 1086 | 256 | 4.22 / 113.86 | 2 | 10 |
7 | 14 | 376.40 | 16 | 14.78 | 808 | 191 | 4.41 / 114.05 | 2 | 10 |
8 | 14 | 219.96 | 16 | 14.79 | 582 | 138 | 4.54 / 114.19 | 2 | 10 |
9 | 14 | 148.20 | 16 | 14.81 | 481 | 114 | 4.66 / 114.30 | 2 | 9 |
10 | 14 | 78.52 | 16 | 14.81 | 378 | 90 | 4.75 / 114.39 | 2 | 8 |
11 | 14 | 22.20 | 16 | 14.82 | 301 | 71 | 4.82 / 114.46 | 2 | 8 |
12 | 9 | 0.04 | 163 | 14.81 | 265 | 640 | 5.46 / 115.10 | 2 | 63 |
13 | 15 | -0.12 | 57 | 14.81 | 188 | 159 | 5.62 / 115.26 | 13 | 247 |
Average= | 3.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.92 | 43 | 14.79 | 407 | 259 | 0.26 / 104.10 | 2 | 3 |
2 | 3 | 1022.68 | 1 | 14.85 | 1677 | 25 | 0.28 / 104.12 | 2 | 4 |
3 | 3 | 1019.44 | 1 | 14.86 | 1682 | 25 | 0.31 / 104.15 | 2 | 4 |
4 | 8 | 2006.04 | 58 | 14.54 | 2856 | 2409 | 2.72 / 106.56 | 2 | 6 |
5 | 14 | 1498.84 | 16 | 14.61 | 2255 | 527 | 3.24 / 107.08 | 2 | 7 |
6 | 14 | 1347.60 | 16 | 14.61 | 2068 | 483 | 3.73 / 107.57 | 2 | 9 |
7 | 14 | 918.64 | 16 | 14.68 | 1523 | 358 | 4.09 / 107.92 | 2 | 9 |
8 | 14 | 661.48 | 16 | 14.72 | 1185 | 279 | 4.36 / 108.20 | 2 | 10 |
9 | 14 | 439.68 | 16 | 14.76 | 890 | 210 | 4.57 / 108.41 | 2 | 10 |
10 | 14 | 226.08 | 16 | 14.80 | 594 | 141 | 4.72 / 108.55 | 2 | 10 |
11 | 14 | 151.84 | 16 | 14.81 | 491 | 116 | 4.83 / 108.67 | 2 | 9 |
12 | 14 | 85.40 | 16 | 14.81 | 392 | 93 | 4.92 / 108.76 | 2 | 9 |
13 | 14 | 30.92 | 16 | 14.82 | 316 | 75 | 5.00 / 108.84 | 2 | 8 |
14 | 9 | 0.60 | 165 | 14.81 | 267 | 652 | 5.65 / 109.49 | 2 | 82 |
15 | 15 | -0.04 | 55 | 14.82 | 191 | 156 | 5.81 / 109.65 | 14 | 247 |
Average= | 3.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.28 | 43 | 14.81 | 400 | 255 | 0.25 / 98.44 | 2 | 3 |
2 | 8 | 2004.80 | 58 | 14.53 | 2855 | 2406 | 2.66 / 100.84 | 2 | 4 |
3 | 14 | 1458.36 | 16 | 14.60 | 2212 | 517 | 3.18 / 101.36 | 2 | 7 |
4 | 14 | 1084.48 | 16 | 14.66 | 1747 | 410 | 3.59 / 101.77 | 2 | 7 |
5 | 14 | 886.28 | 16 | 14.68 | 1485 | 349 | 3.94 / 102.12 | 2 | 8 |
6 | 14 | 635.76 | 16 | 14.73 | 1158 | 273 | 4.21 / 102.39 | 2 | 9 |
7 | 14 | 385.40 | 16 | 14.77 | 817 | 193 | 4.40 / 102.58 | 2 | 10 |
8 | 14 | 262.60 | 16 | 14.79 | 653 | 155 | 4.56 / 102.74 | 2 | 10 |
9 | 14 | 185.76 | 16 | 14.80 | 542 | 128 | 4.68 / 102.87 | 2 | 10 |
10 | 14 | 81.44 | 16 | 14.81 | 385 | 91 | 4.78 / 102.96 | 2 | 8 |
11 | 14 | 24.64 | 16 | 14.81 | 307 | 73 | 4.85 / 103.03 | 2 | 7 |
12 | 9 | 0.20 | 165 | 14.81 | 267 | 652 | 5.50 / 103.68 | 2 | 100 |
13 | 15 | -0.12 | 55 | 14.82 | 190 | 155 | 5.66 / 103.84 | 16 | 247 |
Average= | 3.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.52 | 43 | 14.80 | 405 | 258 | 0.26 / 92.84 | 2 | 3 |
2 | 8 | 2007.72 | 59 | 14.55 | 2864 | 2459 | 2.72 / 95.30 | 2 | 6 |
3 | 14 | 1435.56 | 16 | 14.63 | 2177 | 510 | 3.23 / 95.81 | 2 | 7 |
4 | 14 | 1123.16 | 16 | 14.67 | 1790 | 420 | 3.65 / 96.23 | 2 | 7 |
5 | 14 | 845.84 | 16 | 14.72 | 1422 | 335 | 3.98 / 96.57 | 2 | 9 |
6 | 14 | 555.92 | 16 | 14.78 | 1046 | 247 | 4.23 / 96.81 | 2 | 9 |
7 | 14 | 395.88 | 16 | 14.80 | 827 | 196 | 4.42 / 97.01 | 2 | 10 |
8 | 14 | 234.16 | 16 | 14.83 | 605 | 144 | 4.57 / 97.15 | 2 | 10 |
9 | 14 | 156.80 | 16 | 14.84 | 495 | 118 | 4.69 / 97.27 | 2 | 9 |
10 | 14 | 86.68 | 16 | 14.84 | 390 | 93 | 4.78 / 97.36 | 2 | 9 |
11 | 9 | 0.08 | 178 | 14.83 | 264 | 697 | 5.47 / 98.06 | 2 | 58 |
12 | 15 | 0.00 | 42 | 14.82 | 197 | 123 | 5.60 / 98.18 | 11 | 247 |
Average= | 3.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.52 | 43 | 14.72 | 404 | 256 | 0.26 / 87.31 | 2 | 3 |
2 | 8 | 2008.00 | 58 | 14.56 | 2857 | 2413 | 2.67 / 89.72 | 2 | 5 |
3 | 14 | 1410.68 | 16 | 14.64 | 2143 | 502 | 3.17 / 90.22 | 2 | 6 |
4 | 14 | 1137.16 | 16 | 14.67 | 1803 | 423 | 3.59 / 90.65 | 2 | 7 |
5 | 14 | 893.32 | 16 | 14.70 | 1488 | 350 | 3.94 / 91.00 | 2 | 8 |
6 | 14 | 523.12 | 16 | 14.76 | 1001 | 236 | 4.18 / 91.23 | 2 | 9 |
7 | 14 | 366.12 | 16 | 14.80 | 787 | 186 | 4.37 / 91.42 | 2 | 10 |
8 | 14 | 211.44 | 16 | 14.83 | 576 | 137 | 4.50 / 91.56 | 2 | 9 |
9 | 14 | 140.80 | 16 | 14.83 | 472 | 112 | 4.61 / 91.67 | 2 | 9 |
10 | 14 | 68.96 | 16 | 14.83 | 370 | 88 | 4.70 / 91.76 | 2 | 8 |
11 | 9 | 0.64 | 180 | 14.82 | 267 | 712 | 5.42 / 92.47 | 2 | 86 |
12 | 15 | -0.08 | 40 | 14.81 | 194 | 115 | 5.53 / 92.58 | 16 | 247 |
Average= | 3.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.84 | 43 | 14.74 | 400 | 254 | 0.25 / 79.82 | 2 | 3 |
2 | 8 | 1908.64 | 150 | 14.33 | 2753 | 5918 | 6.17 / 85.74 | 2 | 5 |
3 | 14 | 312.84 | 16 | 14.71 | 711 | 167 | 6.34 / 85.91 | 2 | 9 |
4 | 14 | 227.00 | 16 | 14.72 | 603 | 142 | 6.48 / 86.05 | 2 | 9 |
5 | 14 | 146.44 | 16 | 14.71 | 483 | 114 | 6.59 / 86.16 | 2 | 8 |
6 | 14 | 59.96 | 16 | 14.73 | 359 | 85 | 6.68 / 86.25 | 2 | 7 |
7 | 9 | 0.12 | 172 | 14.72 | 266 | 673 | 7.35 / 86.92 | 2 | 67 |
8 | 15 | -0.04 | 48 | 14.72 | 191 | 135 | 7.49 / 87.05 | 11 | 247 |
Average= | 3.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.24 | 44 | 14.76 | 391 | 254 | 0.25 / 72.90 | 2 | 3 |
2 | 3 | 972.20 | -1 | 15.18 | 4 | 0 | 0.00 / 72.90 | 2 | 3 |
3 | 8 | 1724.12 | 150 | 14.42 | 2509 | 5427 | 5.68 / 78.32 | 2 | 4 |
4 | 14 | 266.48 | 16 | 14.76 | 647 | 153 | 5.83 / 78.48 | 2 | 9 |
5 | 14 | 186.84 | 16 | 14.75 | 535 | 126 | 5.96 / 78.60 | 2 | 8 |
6 | 14 | 108.44 | 16 | 14.76 | 421 | 99 | 6.06 / 78.70 | 2 | 7 |
7 | 14 | 33.56 | 16 | 14.77 | 314 | 74 | 6.13 / 78.77 | 2 | 7 |
8 | 9 | 0.56 | 168 | 14.76 | 261 | 647 | 6.78 / 79.42 | 2 | 68 |
9 | 15 | -0.08 | 52 | 14.76 | 189 | 145 | 6.93 / 79.57 | 14 | 247 |
Average= | 3.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.76 | 44 | 14.75 | 404 | 262 | 0.26 / 66.83 | 2 | 3 |
2 | 3 | 967.68 | -1 | 15.18 | 4 | 0 | 0.00 / 66.83 | 2 | 3 |
3 | 8 | 1436.12 | 150 | 14.52 | 2150 | 4683 | 4.94 / 71.52 | 2 | 5 |
4 | 14 | 209.12 | 16 | 14.76 | 558 | 132 | 5.08 / 71.65 | 2 | 8 |
5 | 14 | 134.24 | 16 | 14.77 | 457 | 108 | 5.18 / 71.76 | 2 | 7 |
6 | 14 | 52.84 | 16 | 14.78 | 340 | 80 | 5.27 / 71.84 | 2 | 6 |
7 | 9 | 0.04 | 176 | 14.78 | 261 | 679 | 5.94 / 72.52 | 2 | 63 |
8 | 15 | -0.08 | 44 | 14.77 | 193 | 125 | 6.07 / 72.64 | 14 | 247 |
Average= | 3.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.28 | 45 | 14.80 | 392 | 261 | 0.26 / 60.75 | 3 | 3 |
2 | 3 | 949.08 | -1 | 15.20 | 4 | 0 | 0.00 / 60.75 | 3 | 3 |
3 | 3 | 967.60 | -1 | 15.21 | 4 | 0 | 0.00 / 60.75 | 3 | 3 |
4 | 8 | 1414.44 | 151 | 14.54 | 2127 | 4670 | 4.93 / 65.42 | 2 | 5 |
5 | 14 | 219.40 | 16 | 14.75 | 585 | 138 | 5.07 / 65.56 | 2 | 8 |
6 | 14 | 134.44 | 16 | 14.78 | 466 | 110 | 5.18 / 65.67 | 2 | 8 |
7 | 14 | 56.76 | 16 | 14.78 | 352 | 83 | 5.26 / 65.76 | 2 | 7 |
8 | 9 | 0.12 | 176 | 14.79 | 265 | 690 | 5.95 / 66.45 | 2 | 69 |
9 | 15 | 0.16 | 44 | 14.78 | 195 | 127 | 6.08 / 66.57 | 13 | 247 |
Average= | 3.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.76 | 38 | 14.81 | 393 | 221 | 0.22 / 55.84 | 2 | 3 |
2 | 3 | 731.20 | -5 | 15.14 | 4 | 0 | 0.00 / 55.84 | 2 | 3 |
3 | 3 | 875.80 | -2 | 15.16 | 4 | 0 | 0.00 / 55.84 | 2 | 3 |
4 | 8 | 1127.76 | 150 | 14.64 | 1736 | 3812 | 4.03 / 59.65 | 2 | 6 |
5 | 14 | 34.60 | 16 | 14.83 | 299 | 71 | 4.10 / 59.73 | 2 | 5 |
6 | 9 | 0.08 | 172 | 14.83 | 249 | 635 | 4.74 / 60.36 | 2 | 64 |
7 | 15 | -0.12 | 48 | 14.82 | 186 | 132 | 4.87 / 60.49 | 13 | 247 |
Average= | 2.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.00 | 41 | 14.84 | 403 | 245 | 0.25 / 50.90 | 2 | 3 |
2 | 3 | 713.68 | -5 | 15.16 | 4 | 0 | 0.00 / 50.90 | 2 | 3 |
3 | 3 | 846.56 | -3 | 15.20 | 5 | 0 | 0.00 / 50.90 | 2 | 3 |
4 | 8 | 1135.12 | 150 | 14.67 | 1749 | 3849 | 4.09 / 54.75 | 2 | 5 |
5 | 14 | 25.48 | 16 | 14.86 | 295 | 70 | 4.16 / 54.82 | 2 | 6 |
6 | 9 | 0.04 | 170 | 14.85 | 260 | 656 | 4.82 / 55.48 | 2 | 68 |
7 | 15 | -0.04 | 50 | 14.84 | 193 | 143 | 4.96 / 55.62 | 15 | 247 |
Average= | 2.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.24 | 45 | 14.82 | 392 | 261 | 0.26 / 45.96 | 3 | 3 |
2 | 3 | 690.24 | -6 | 15.15 | 4 | 0 | 0.00 / 45.96 | 3 | 3 |
3 | 3 | 817.04 | -3 | 15.18 | 4 | 0 | 0.00 / 45.96 | 3 | 3 |
4 | 8 | 1129.08 | 150 | 14.69 | 1739 | 3832 | 4.09 / 49.79 | 2 | 5 |
5 | 14 | 47.96 | 16 | 14.86 | 328 | 78 | 4.17 / 49.87 | 2 | 6 |
6 | 9 | 0.12 | 168 | 14.86 | 258 | 644 | 4.82 / 50.51 | 2 | 56 |
7 | 15 | 0.00 | 52 | 14.85 | 189 | 146 | 4.96 / 50.66 | 13 | 247 |
Average= | 2.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.72 | 69 | 14.86 | 402 | 412 | 0.41 / 42.12 | 3 | 3 |
2 | 3 | 382.64 | -2 | 15.12 | 4 | 0 | 0.00 / 42.12 | 3 | 3 |
3 | 3 | 462.24 | -1 | 15.16 | 4 | 0 | 0.00 / 42.12 | 3 | 3 |
4 | 8 | 691.68 | 150 | 14.84 | 1186 | 2640 | 3.05 / 44.76 | 2 | 5 |
5 | 14 | 133.00 | 16 | 14.88 | 429 | 102 | 3.15 / 44.86 | 2 | 4 |
6 | 14 | 44.80 | 16 | 14.89 | 311 | 74 | 3.23 / 44.94 | 2 | 4 |
7 | 9 | 0.12 | 176 | 14.89 | 244 | 639 | 3.87 / 45.57 | 2 | 68 |
8 | 15 | 0.12 | 44 | 14.88 | 185 | 121 | 3.99 / 45.70 | 13 | 246 |
Average= | 2.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.12 | 70 | 14.90 | 387 | 404 | 0.40 / 38.21 | 3 | 3 |
2 | 3 | 375.52 | -2 | 15.14 | 5 | 0 | 0.00 / 38.21 | 3 | 3 |
3 | 3 | 456.24 | -1 | 15.19 | 4 | 0 | 0.00 / 38.21 | 3 | 3 |
4 | 8 | 664.84 | 150 | 14.87 | 1146 | 2556 | 2.96 / 40.77 | 2 | 3 |
5 | 14 | 118.76 | 16 | 14.91 | 412 | 98 | 3.06 / 40.86 | 2 | 4 |
6 | 14 | 36.48 | 16 | 14.91 | 302 | 72 | 3.13 / 40.94 | 2 | 4 |
7 | 9 | 0.16 | 176 | 14.91 | 247 | 648 | 3.78 / 41.58 | 2 | 58 |
8 | 15 | 0.24 | 44 | 14.91 | 187 | 123 | 3.90 / 41.71 | 14 | 246 |
Average= | 2.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.40 | 103 | 14.90 | 398 | 611 | 0.61 / 36.13 | 3 | 3 |
2 | 8 | 197.24 | 150 | 14.95 | 473 | 1061 | 1.67 / 37.19 | 3 | 5 |
3 | 9 | -0.04 | 99 | 14.95 | 225 | 333 | 2.00 / 37.53 | 3 | 94 |
4 | 15 | 0.00 | 121 | 14.95 | 155 | 280 | 2.28 / 37.81 | 18 | 246 |
Average= | 2.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.96 | 103 | 14.89 | 394 | 604 | 0.60 / 33.83 | 3 | 3 |
2 | 8 | 203.44 | 150 | 14.94 | 482 | 1080 | 1.68 / 34.91 | 3 | 4 |
3 | 9 | -0.08 | 101 | 14.94 | 224 | 338 | 2.02 / 35.24 | 3 | 85 |
4 | 15 | -0.08 | 119 | 14.94 | 156 | 277 | 2.30 / 35.52 | 18 | 246 |
Average= | 2.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.12 | 103 | 14.89 | 395 | 606 | 0.61 / 31.52 | 3 | 3 |
2 | 8 | 207.64 | 150 | 14.94 | 488 | 1094 | 1.70 / 32.61 | 3 | 4 |
3 | 9 | 0.08 | 101 | 14.94 | 223 | 336 | 2.04 / 32.95 | 3 | 146 |
4 | 15 | -0.04 | 119 | 14.95 | 155 | 276 | 2.31 / 33.22 | 19 | 246 |
Average= | 2.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.48 | 103 | 14.89 | 391 | 600 | 0.60 / 29.19 | 3 | 3 |
2 | 8 | 214.24 | 150 | 14.93 | 496 | 1111 | 1.71 / 30.30 | 3 | 4 |
3 | 9 | 0.00 | 99 | 14.94 | 224 | 331 | 2.04 / 30.63 | 3 | 54 |
4 | 15 | -0.04 | 121 | 14.94 | 155 | 280 | 2.32 / 30.91 | 12 | 246 |
Average= | 2.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.12 | 103 | 14.88 | 398 | 610 | 0.61 / 26.85 | 3 | 3 |
2 | 8 | 214.72 | 150 | 14.93 | 501 | 1122 | 1.73 / 27.98 | 3 | 4 |
3 | 9 | 0.08 | 101 | 14.92 | 226 | 341 | 2.07 / 28.32 | 3 | 111 |
4 | 15 | 0.04 | 119 | 14.92 | 153 | 272 | 2.34 / 28.59 | 18 | 246 |
Average= | 2.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.64 | 103 | 14.86 | 397 | 608 | 0.61 / 24.51 | 3 | 3 |
2 | 8 | 214.20 | 150 | 14.93 | 499 | 1118 | 1.73 / 25.63 | 3 | 4 |
3 | 9 | -0.08 | 101 | 14.92 | 227 | 342 | 2.07 / 25.97 | 3 | 87 |
4 | 15 | 0.08 | 119 | 14.93 | 154 | 274 | 2.34 / 26.24 | 17 | 246 |
Average= | 2.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.88 | 103 | 14.87 | 402 | 616 | 0.62 / 22.17 | 3 | 3 |
2 | 8 | 212.84 | 150 | 14.93 | 500 | 1120 | 1.74 / 23.29 | 3 | 4 |
3 | 9 | 0.00 | 101 | 14.92 | 226 | 341 | 2.08 / 23.63 | 3 | 62 |
4 | 15 | -0.04 | 119 | 14.93 | 156 | 277 | 2.35 / 23.90 | 18 | 246 |
Average= | 2.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.20 | 103 | 14.86 | 390 | 597 | 0.60 / 19.84 | 3 | 3 |
2 | 8 | 207.60 | 150 | 14.92 | 489 | 1094 | 1.69 / 20.93 | 3 | 5 |
3 | 9 | 0.00 | 103 | 14.92 | 226 | 347 | 2.04 / 21.28 | 3 | 169 |
4 | 15 | -0.04 | 117 | 14.93 | 155 | 271 | 2.31 / 21.55 | 22 | 246 |
Average= | 2.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.40 | 103 | 14.84 | 401 | 613 | 0.61 / 17.52 | 3 | 3 |
2 | 8 | 205.72 | 150 | 14.91 | 494 | 1105 | 1.72 / 18.62 | 3 | 4 |
3 | 9 | 0.04 | 101 | 14.91 | 228 | 343 | 2.06 / 18.96 | 3 | 53 |
4 | 15 | -0.04 | 119 | 14.91 | 156 | 277 | 2.34 / 19.24 | 15 | 246 |
Average= | 2.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.40 | 103 | 14.83 | 393 | 600 | 0.60 / 14.98 | 3 | 3 |
2 | 11 | 255.64 | 2 | 14.91 | 569 | 17 | 0.62 / 14.99 | 3 | 3 |
3 | 8 | 255.88 | 150 | 14.88 | 565 | 1261 | 1.88 / 16.26 | 3 | 4 |
4 | 9 | 0.08 | 118 | 14.89 | 230 | 404 | 2.28 / 16.66 | 3 | 57 |
5 | 15 | 0.08 | 102 | 14.89 | 160 | 243 | 2.53 / 16.90 | 16 | 246 |
Average= | 2.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.00 | 103 | 14.81 | 401 | 612 | 0.61 / 12.36 | 3 | 3 |
2 | 11 | 272.44 | 3 | 14.92 | 620 | 28 | 0.64 / 12.39 | 3 | 3 |
3 | 8 | 277.20 | 150 | 14.87 | 594 | 1325 | 1.96 / 13.71 | 3 | 4 |
4 | 9 | 0.04 | 125 | 14.88 | 232 | 432 | 2.40 / 14.14 | 3 | 56 |
5 | 15 | -0.08 | 95 | 14.87 | 166 | 234 | 2.63 / 14.38 | 19 | 246 |
Average= | 2.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.20 | 103 | 14.82 | 402 | 614 | 0.61 / 9.75 | 3 | 3 |
2 | 11 | 270.16 | 3 | 14.92 | 614 | 27 | 0.64 / 9.78 | 3 | 3 |
3 | 8 | 274.00 | 150 | 14.87 | 589 | 1314 | 1.95 / 11.09 | 3 | 4 |
4 | 9 | -0.04 | 123 | 14.87 | 232 | 424 | 2.38 / 11.51 | 3 | 59 |
5 | 15 | -0.04 | 97 | 14.88 | 161 | 232 | 2.61 / 11.75 | 20 | 246 |
Average= | 2.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.56 | 103 | 14.82 | 385 | 588 | 0.59 / 7.29 | 3 | 3 |
2 | 8 | 248.60 | 150 | 14.89 | 542 | 1211 | 1.80 / 8.50 | 3 | 4 |
3 | 9 | 0.20 | 118 | 14.88 | 223 | 392 | 2.19 / 8.89 | 3 | 59 |
4 | 15 | -0.12 | 102 | 14.87 | 159 | 241 | 2.43 / 9.13 | 17 | 246 |
Average= | 2.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.36 | 103 | 14.89 | 389 | 597 | 0.60 / 4.91 | 3 | 3 |
2 | 8 | 235.24 | 150 | 14.91 | 525 | 1174 | 1.77 / 6.09 | 3 | 4 |
3 | 9 | 0.04 | 114 | 14.90 | 219 | 372 | 2.14 / 6.46 | 3 | 73 |
4 | 15 | -0.16 | 106 | 14.91 | 156 | 247 | 2.39 / 6.70 | 23 | 247 |
Average= | 2.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.52 | 103 | 15.05 | 388 | 601 | 0.60 / 2.60 | 3 | 3 |
2 | 8 | 208.04 | 151 | 15.01 | 485 | 1099 | 1.70 / 3.70 | 3 | 5 |
3 | 9 | -0.04 | 103 | 14.97 | 220 | 339 | 2.04 / 4.04 | 3 | 53 |
4 | 15 | -0.08 | 117 | 14.97 | 156 | 273 | 2.31 / 4.31 | 17 | 247 |
Average= | 2.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 58.76 | 103 | 15.24 | 352 | 553 | 0.55 / 0.55 | 3 | 3 |
2 | 8 | 95.08 | 150 | 15.18 | 360 | 820 | 1.37 / 1.37 | 3 | 6 |
3 | 9 | 0.16 | 97 | 15.14 | 233 | 342 | 1.71 / 1.71 | 3 | 60 |
4 | 15 | 0.08 | 123 | 15.15 | 154 | 287 | 2.00 / 2.00 | 23 | 246 |
Average= | 2.00 (KJ/cycle) |