SIO Argo Site:
|
![]() |
![]() |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.60 | 31 | 14.77 | 502 | 230 | 0.23 / 147.15 | 5 | 5 |
2 | 7 | 2003.68 | 40 | 14.33 | 3240 | 1857 | 2.09 / 149.01 | 5 | 5 |
3 | 13 | 1523.36 | 20 | 14.38 | 2563 | 737 | 2.82 / 149.74 | 5 | 7 |
4 | 13 | 724.84 | 20 | 14.58 | 1404 | 409 | 3.23 / 150.15 | 5 | 9 |
5 | 13 | 70.92 | 20 | 14.83 | 427 | 127 | 3.36 / 150.28 | 5 | 6 |
6 | 8 | 0.00 | 295 | 14.78 | 325 | 1417 | 4.78 / 151.70 | 5 | 151 |
Average= | 4.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.24 | 31 | 14.78 | 495 | 227 | 0.23 / 142.32 | 5 | 5 |
2 | 3 | 1032.36 | 1 | 14.77 | 1842 | 27 | 0.25 / 142.35 | 5 | 6 |
3 | 7 | 2005.36 | 40 | 14.35 | 3245 | 1863 | 2.12 / 144.21 | 6 | 7 |
4 | 13 | 1468.36 | 20 | 14.40 | 2493 | 718 | 2.83 / 144.93 | 5 | 6 |
5 | 13 | 873.76 | 20 | 14.53 | 1626 | 473 | 3.31 / 145.40 | 5 | 9 |
6 | 13 | 35.12 | 20 | 14.85 | 374 | 111 | 3.42 / 145.51 | 5 | 6 |
7 | 8 | 0.20 | 295 | 14.80 | 322 | 1406 | 4.82 / 146.92 | 5 | 151 |
Average= | 4.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.68 | 31 | 14.76 | 511 | 234 | 0.23 / 137.46 | 5 | 5 |
2 | 7 | 2008.00 | 40 | 14.35 | 3261 | 1872 | 2.11 / 139.33 | 5 | 6 |
3 | 13 | 1453.52 | 20 | 14.41 | 2463 | 710 | 2.82 / 140.04 | 5 | 8 |
4 | 13 | 974.60 | 20 | 14.51 | 1786 | 518 | 3.33 / 140.56 | 5 | 9 |
5 | 13 | 64.32 | 20 | 14.85 | 418 | 124 | 3.46 / 140.69 | 5 | 7 |
6 | 8 | -0.12 | 293 | 14.80 | 325 | 1409 | 4.87 / 142.09 | 5 | 134 |
Average= | 4.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.12 | 31 | 14.77 | 492 | 225 | 0.23 / 132.54 | 5 | 5 |
2 | 7 | 2002.72 | 40 | 14.34 | 3243 | 1860 | 2.09 / 134.40 | 5 | 6 |
3 | 13 | 1553.68 | 20 | 14.39 | 2614 | 752 | 2.84 / 135.15 | 5 | 7 |
4 | 13 | 818.68 | 20 | 14.56 | 1551 | 452 | 3.29 / 135.60 | 5 | 10 |
5 | 13 | 109.36 | 20 | 14.82 | 498 | 148 | 3.44 / 135.75 | 5 | 8 |
6 | 8 | 0.04 | 300 | 14.79 | 333 | 1478 | 4.91 / 137.23 | 5 | 139 |
Average= | 4.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.32 | 28 | 14.76 | 506 | 209 | 0.21 / 127.55 | 5 | 5 |
2 | 10 | 1001.52 | 4 | 14.66 | 1819 | 107 | 0.32 / 127.66 | 5 | 5 |
3 | 7 | 2014.76 | 40 | 14.33 | 3262 | 1870 | 2.19 / 129.53 | 5 | 6 |
4 | 13 | 1565.52 | 20 | 14.38 | 2636 | 758 | 2.94 / 130.29 | 5 | 8 |
5 | 13 | 848.12 | 20 | 14.55 | 1602 | 466 | 3.41 / 130.75 | 5 | 10 |
6 | 8 | 0.12 | 319 | 14.80 | 330 | 1558 | 4.97 / 132.31 | 5 | 134 |
Average= | 4.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.64 | 30 | 14.77 | 507 | 225 | 0.22 / 122.76 | 5 | 5 |
2 | 3 | 941.68 | -1 | 15.21 | 0 | 0 | 0.00 / 122.76 | 5 | 5 |
3 | 7 | 2019.84 | 40 | 14.34 | 3280 | 1881 | 2.11 / 124.64 | 5 | 6 |
4 | 13 | 1362.40 | 20 | 14.44 | 2347 | 678 | 2.78 / 125.32 | 5 | 9 |
5 | 13 | 810.72 | 20 | 14.56 | 1545 | 450 | 3.23 / 125.77 | 5 | 10 |
6 | 8 | 0.12 | 321 | 14.80 | 331 | 1573 | 4.81 / 127.34 | 5 | 133 |
Average= | 4.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.20 | 30 | 14.78 | 488 | 216 | 0.22 / 117.88 | 5 | 5 |
2 | 7 | 2006.76 | 40 | 14.33 | 3261 | 1869 | 2.09 / 119.75 | 5 | 6 |
3 | 13 | 1374.64 | 20 | 14.43 | 2365 | 683 | 2.77 / 120.43 | 5 | 8 |
4 | 13 | 795.04 | 20 | 14.56 | 1524 | 444 | 3.21 / 120.88 | 5 | 10 |
5 | 13 | 214.16 | 20 | 14.77 | 659 | 195 | 3.41 / 121.07 | 5 | 9 |
6 | 13 | 22.84 | 20 | 14.84 | 366 | 109 | 3.52 / 121.18 | 5 | 7 |
7 | 8 | 0.16 | 278 | 14.79 | 330 | 1357 | 4.87 / 122.54 | 5 | 136 |
Average= | 4.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.48 | 29 | 14.80 | 489 | 210 | 0.21 / 112.95 | 5 | 5 |
2 | 3 | 1018.64 | 1 | 14.78 | 1816 | 27 | 0.24 / 112.98 | 5 | 6 |
3 | 7 | 2014.12 | 40 | 14.34 | 3272 | 1877 | 2.11 / 114.85 | 6 | 6 |
4 | 13 | 1573.00 | 20 | 14.39 | 2649 | 762 | 2.88 / 115.62 | 5 | 7 |
5 | 13 | 851.48 | 20 | 14.56 | 1612 | 469 | 3.35 / 116.09 | 5 | 10 |
6 | 13 | 86.92 | 20 | 14.84 | 466 | 138 | 3.48 / 116.22 | 5 | 7 |
7 | 8 | -0.04 | 295 | 14.81 | 330 | 1442 | 4.93 / 117.67 | 5 | 153 |
Average= | 4.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.92 | 30 | 14.78 | 481 | 213 | 0.21 / 108.18 | 5 | 5 |
2 | 3 | 963.92 | -1 | 15.22 | 0 | 0 | 0.00 / 108.18 | 5 | 5 |
3 | 7 | 2007.52 | 40 | 14.36 | 3274 | 1881 | 2.09 / 110.06 | 5 | 7 |
4 | 13 | 1365.12 | 20 | 14.46 | 2342 | 677 | 2.77 / 110.74 | 5 | 8 |
5 | 13 | 791.48 | 20 | 14.59 | 1517 | 443 | 3.21 / 111.18 | 5 | 10 |
6 | 13 | 57.60 | 20 | 14.86 | 414 | 123 | 3.34 / 111.30 | 5 | 7 |
7 | 8 | 0.76 | 293 | 14.82 | 331 | 1437 | 4.77 / 112.74 | 5 | 139 |
Average= | 4.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.56 | 30 | 14.79 | 508 | 225 | 0.23 / 103.38 | 5 | 5 |
2 | 3 | 1029.72 | 1 | 14.75 | 1858 | 27 | 0.25 / 103.41 | 5 | 6 |
3 | 7 | 2006.16 | 40 | 14.35 | 3258 | 1870 | 2.12 / 105.28 | 6 | 6 |
4 | 13 | 1333.84 | 20 | 14.46 | 2307 | 667 | 2.79 / 105.95 | 5 | 10 |
5 | 13 | 691.20 | 20 | 14.62 | 1366 | 399 | 3.19 / 106.35 | 5 | 10 |
6 | 13 | 125.32 | 20 | 14.83 | 521 | 155 | 3.34 / 106.50 | 5 | 8 |
7 | 8 | 0.56 | 295 | 14.81 | 335 | 1464 | 4.81 / 107.97 | 5 | 153 |
Average= | 4.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.68 | 30 | 14.79 | 489 | 217 | 0.22 / 98.55 | 5 | 5 |
2 | 7 | 2007.76 | 40 | 14.36 | 3262 | 1874 | 2.09 / 100.42 | 5 | 6 |
3 | 13 | 1449.00 | 20 | 14.43 | 2470 | 713 | 2.80 / 101.14 | 5 | 11 |
4 | 13 | 757.88 | 20 | 14.60 | 1469 | 429 | 3.23 / 101.56 | 5 | 10 |
5 | 13 | 94.08 | 20 | 14.84 | 475 | 141 | 3.37 / 101.71 | 5 | 8 |
6 | 8 | -0.36 | 293 | 14.81 | 335 | 1454 | 4.83 / 103.16 | 5 | 150 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.36 | 30 | 14.78 | 486 | 215 | 0.22 / 93.68 | 5 | 5 |
2 | 7 | 2014.52 | 40 | 14.36 | 3268 | 1877 | 2.09 / 95.56 | 5 | 6 |
3 | 13 | 1559.04 | 20 | 14.41 | 2640 | 761 | 2.85 / 96.32 | 5 | 8 |
4 | 13 | 756.28 | 20 | 14.61 | 1459 | 426 | 3.28 / 96.74 | 5 | 10 |
5 | 13 | 89.00 | 20 | 14.85 | 465 | 138 | 3.42 / 96.88 | 5 | 7 |
6 | 8 | -0.08 | 295 | 14.82 | 332 | 1451 | 4.87 / 98.33 | 5 | 159 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.64 | 30 | 14.81 | 484 | 215 | 0.22 / 88.81 | 5 | 5 |
2 | 3 | 1022.36 | 1 | 14.78 | 1848 | 27 | 0.24 / 88.84 | 5 | 5 |
3 | 7 | 2003.16 | 41 | 14.36 | 3241 | 1908 | 2.15 / 90.74 | 5 | 7 |
4 | 13 | 1436.00 | 20 | 14.45 | 2441 | 705 | 2.86 / 91.45 | 5 | 8 |
5 | 13 | 743.56 | 20 | 14.61 | 1446 | 423 | 3.28 / 91.87 | 5 | 9 |
6 | 13 | 143.12 | 20 | 14.83 | 549 | 163 | 3.44 / 92.03 | 5 | 8 |
7 | 8 | 0.08 | 293 | 14.82 | 329 | 1429 | 4.87 / 93.46 | 5 | 152 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.72 | 30 | 14.78 | 486 | 215 | 0.22 / 84.02 | 5 | 5 |
2 | 7 | 2004.00 | 40 | 14.37 | 3251 | 1869 | 2.08 / 85.88 | 5 | 6 |
3 | 13 | 1412.64 | 20 | 14.46 | 2418 | 699 | 2.78 / 86.58 | 5 | 9 |
4 | 13 | 820.04 | 20 | 14.60 | 1551 | 453 | 3.24 / 87.04 | 5 | 10 |
5 | 13 | 104.76 | 20 | 14.86 | 485 | 144 | 3.38 / 87.18 | 5 | 7 |
6 | 8 | 0.40 | 291 | 14.84 | 327 | 1412 | 4.79 / 88.59 | 5 | 146 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.12 | 30 | 14.79 | 488 | 217 | 0.22 / 79.21 | 5 | 5 |
2 | 7 | 2005.04 | 40 | 14.37 | 3246 | 1866 | 2.08 / 81.07 | 5 | 6 |
3 | 13 | 1437.60 | 20 | 14.46 | 2448 | 708 | 2.79 / 81.78 | 5 | 8 |
4 | 13 | 766.28 | 20 | 14.61 | 1468 | 429 | 3.22 / 82.21 | 5 | 10 |
5 | 13 | 91.68 | 20 | 14.85 | 473 | 140 | 3.36 / 82.35 | 5 | 8 |
6 | 8 | 0.16 | 293 | 14.82 | 334 | 1450 | 4.81 / 83.80 | 5 | 153 |
Average= | 4.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.56 | 31 | 14.81 | 497 | 228 | 0.23 / 74.33 | 5 | 5 |
2 | 7 | 2003.72 | 40 | 14.38 | 3244 | 1866 | 2.09 / 76.19 | 5 | 6 |
3 | 13 | 1539.96 | 20 | 14.44 | 2591 | 748 | 2.84 / 76.94 | 5 | 7 |
4 | 13 | 836.12 | 20 | 14.59 | 1583 | 462 | 3.30 / 77.40 | 5 | 10 |
5 | 13 | 113.68 | 20 | 14.85 | 506 | 150 | 3.45 / 77.55 | 5 | 8 |
6 | 8 | 0.16 | 293 | 14.83 | 331 | 1438 | 4.89 / 78.99 | 5 | 171 |
Average= | 4.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.80 | 31 | 14.83 | 486 | 223 | 0.22 / 69.52 | 5 | 5 |
2 | 7 | 2012.88 | 40 | 14.38 | 3261 | 1876 | 2.10 / 71.39 | 5 | 6 |
3 | 13 | 1434.12 | 20 | 14.46 | 2446 | 707 | 2.81 / 72.10 | 5 | 8 |
4 | 13 | 841.96 | 20 | 14.59 | 1585 | 463 | 3.27 / 72.56 | 5 | 9 |
5 | 13 | 67.60 | 20 | 14.87 | 429 | 128 | 3.40 / 72.69 | 5 | 7 |
6 | 8 | 0.04 | 289 | 14.84 | 328 | 1407 | 4.80 / 74.10 | 5 | 139 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.56 | 31 | 14.83 | 480 | 221 | 0.22 / 64.80 | 5 | 5 |
2 | 7 | 2006.52 | 40 | 14.38 | 3251 | 1870 | 2.09 / 66.67 | 5 | 5 |
3 | 13 | 1365.04 | 20 | 14.48 | 2332 | 675 | 2.77 / 67.35 | 5 | 7 |
4 | 13 | 790.36 | 20 | 14.62 | 1503 | 439 | 3.21 / 67.79 | 5 | 8 |
5 | 13 | 90.32 | 20 | 14.88 | 459 | 137 | 3.34 / 67.92 | 5 | 6 |
6 | 8 | -0.04 | 287 | 14.85 | 322 | 1372 | 4.71 / 69.29 | 5 | 154 |
Average= | 4.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.64 | 30 | 14.84 | 485 | 216 | 0.22 / 60.03 | 5 | 5 |
2 | 3 | 1030.20 | 1 | 14.82 | 1834 | 27 | 0.24 / 60.06 | 5 | 6 |
3 | 7 | 2007.52 | 40 | 14.39 | 3242 | 1866 | 2.11 / 61.93 | 6 | 6 |
4 | 13 | 1375.24 | 20 | 14.49 | 2354 | 682 | 2.79 / 62.61 | 5 | 7 |
5 | 13 | 807.56 | 20 | 14.62 | 1533 | 448 | 3.24 / 63.06 | 5 | 9 |
6 | 13 | 98.88 | 20 | 14.88 | 472 | 140 | 3.38 / 63.20 | 5 | 6 |
7 | 8 | 0.16 | 287 | 14.86 | 324 | 1382 | 4.76 / 64.58 | 5 | 165 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.20 | 30 | 14.84 | 507 | 226 | 0.23 / 55.20 | 5 | 5 |
2 | 7 | 2008.28 | 40 | 14.40 | 3253 | 1874 | 2.10 / 57.07 | 5 | 6 |
3 | 13 | 1448.76 | 20 | 14.48 | 2458 | 712 | 2.81 / 57.79 | 5 | 7 |
4 | 13 | 861.92 | 20 | 14.62 | 1603 | 469 | 3.28 / 58.25 | 5 | 9 |
5 | 13 | 152.16 | 20 | 14.87 | 552 | 164 | 3.44 / 58.42 | 5 | 6 |
6 | 8 | 0.20 | 287 | 14.86 | 328 | 1399 | 4.84 / 59.82 | 5 | 167 |
Average= | 4.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.08 | 30 | 14.85 | 482 | 215 | 0.21 / 50.38 | 5 | 5 |
2 | 7 | 2017.76 | 40 | 14.40 | 3269 | 1883 | 2.10 / 52.26 | 5 | 7 |
3 | 13 | 1449.04 | 20 | 14.48 | 2456 | 711 | 2.81 / 52.98 | 5 | 7 |
4 | 13 | 849.00 | 20 | 14.62 | 1594 | 466 | 3.28 / 53.44 | 5 | 9 |
5 | 13 | 132.00 | 20 | 14.88 | 521 | 155 | 3.43 / 53.60 | 5 | 6 |
6 | 8 | 0.00 | 285 | 14.87 | 325 | 1377 | 4.81 / 54.97 | 5 | 159 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.80 | 30 | 14.86 | 483 | 215 | 0.22 / 45.58 | 5 | 5 |
2 | 7 | 2004.96 | 41 | 14.39 | 3254 | 1920 | 2.14 / 47.49 | 5 | 6 |
3 | 13 | 1429.92 | 20 | 14.49 | 2422 | 702 | 2.84 / 48.20 | 5 | 11 |
4 | 13 | 713.44 | 20 | 14.66 | 1400 | 410 | 3.25 / 48.61 | 5 | 10 |
5 | 13 | 64.92 | 20 | 14.90 | 431 | 128 | 3.38 / 48.74 | 5 | 6 |
6 | 13 | 38.28 | 20 | 14.91 | 394 | 117 | 3.49 / 48.85 | 5 | 7 |
7 | 8 | -0.04 | 263 | 14.87 | 336 | 1314 | 4.81 / 50.17 | 5 | 133 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.52 | 30 | 14.85 | 488 | 217 | 0.22 / 40.79 | 5 | 5 |
2 | 7 | 2009.64 | 40 | 14.40 | 3265 | 1881 | 2.10 / 42.67 | 5 | 6 |
3 | 13 | 1431.32 | 20 | 14.51 | 2431 | 705 | 2.80 / 43.38 | 5 | 8 |
4 | 13 | 835.92 | 20 | 14.63 | 1568 | 459 | 3.26 / 43.84 | 5 | 9 |
5 | 13 | 121.92 | 20 | 14.89 | 505 | 150 | 3.41 / 43.99 | 5 | 6 |
6 | 13 | 22.48 | 20 | 14.92 | 358 | 107 | 3.52 / 44.09 | 5 | 7 |
7 | 8 | 0.16 | 265 | 14.88 | 321 | 1266 | 4.79 / 45.36 | 5 | 151 |
Average= | 4.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.96 | 30 | 14.85 | 482 | 215 | 0.21 / 35.99 | 5 | 5 |
2 | 7 | 2004.76 | 41 | 14.39 | 3241 | 1912 | 2.13 / 37.90 | 5 | 7 |
3 | 13 | 1437.20 | 20 | 14.49 | 2437 | 706 | 2.83 / 38.60 | 5 | 8 |
4 | 13 | 650.56 | 20 | 14.68 | 1309 | 384 | 3.22 / 38.99 | 5 | 10 |
5 | 13 | 88.84 | 20 | 14.88 | 479 | 143 | 3.36 / 39.13 | 5 | 8 |
6 | 13 | 20.36 | 20 | 14.91 | 377 | 112 | 3.47 / 39.24 | 5 | 9 |
7 | 8 | 0.04 | 265 | 14.86 | 338 | 1331 | 4.80 / 40.57 | 5 | 154 |
Average= | 4.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.60 | 30 | 14.85 | 483 | 215 | 0.22 / 31.28 | 5 | 5 |
2 | 7 | 2005.08 | 40 | 14.40 | 3257 | 1876 | 2.09 / 33.16 | 5 | 6 |
3 | 13 | 1327.24 | 20 | 14.52 | 2285 | 664 | 2.75 / 33.82 | 5 | 8 |
4 | 13 | 752.04 | 20 | 14.65 | 1458 | 427 | 3.18 / 34.25 | 5 | 10 |
5 | 13 | 78.24 | 20 | 14.90 | 449 | 134 | 3.32 / 34.38 | 5 | 7 |
6 | 13 | 21.56 | 20 | 14.91 | 365 | 109 | 3.42 / 34.49 | 5 | 8 |
7 | 8 | 0.12 | 263 | 14.87 | 327 | 1279 | 4.70 / 35.77 | 5 | 141 |
Average= | 3.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.44 | 30 | 14.84 | 485 | 216 | 0.22 / 26.53 | 5 | 5 |
2 | 7 | 2008.56 | 40 | 14.40 | 3258 | 1877 | 2.09 / 28.40 | 5 | 6 |
3 | 13 | 1431.36 | 20 | 14.50 | 2434 | 706 | 2.80 / 29.11 | 5 | 7 |
4 | 13 | 736.80 | 20 | 14.66 | 1433 | 420 | 3.22 / 29.53 | 5 | 10 |
5 | 13 | 77.04 | 20 | 14.90 | 450 | 134 | 3.35 / 29.66 | 5 | 8 |
6 | 13 | 20.52 | 20 | 14.91 | 367 | 109 | 3.46 / 29.77 | 5 | 8 |
7 | 8 | 0.00 | 265 | 14.87 | 329 | 1296 | 4.76 / 31.07 | 5 | 164 |
Average= | 3.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.44 | 30 | 14.85 | 479 | 213 | 0.21 / 21.75 | 5 | 5 |
2 | 7 | 2003.44 | 40 | 14.41 | 3238 | 1866 | 2.08 / 23.61 | 5 | 6 |
3 | 13 | 1336.92 | 20 | 14.52 | 2303 | 669 | 2.75 / 24.28 | 5 | 8 |
4 | 13 | 784.32 | 20 | 14.63 | 1505 | 440 | 3.19 / 24.72 | 5 | 10 |
5 | 13 | 93.80 | 20 | 14.87 | 481 | 143 | 3.33 / 24.87 | 5 | 10 |
6 | 13 | 23.12 | 20 | 14.90 | 375 | 112 | 3.44 / 24.98 | 5 | 10 |
7 | 8 | 0.00 | 267 | 14.85 | 336 | 1332 | 4.78 / 26.31 | 5 | 152 |
Average= | 3.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.88 | 31 | 14.88 | 465 | 214 | 0.21 / 17.03 | 5 | 5 |
2 | 3 | 965.24 | -1 | 15.29 | 0 | 0 | 0.00 / 17.03 | 5 | 5 |
3 | 7 | 2010.72 | 40 | 14.41 | 3251 | 1874 | 2.09 / 18.91 | 5 | 6 |
4 | 13 | 1440.28 | 20 | 14.50 | 2435 | 706 | 2.79 / 19.61 | 5 | 8 |
5 | 13 | 730.48 | 20 | 14.66 | 1428 | 419 | 3.21 / 20.03 | 5 | 9 |
6 | 13 | 69.56 | 20 | 14.91 | 430 | 128 | 3.34 / 20.16 | 5 | 7 |
7 | 13 | 14.68 | 20 | 14.92 | 351 | 105 | 3.45 / 20.26 | 5 | 7 |
8 | 8 | 0.12 | 265 | 14.87 | 322 | 1269 | 4.72 / 21.53 | 5 | 155 |
Average= | 3.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.72 | 30 | 14.89 | 455 | 203 | 0.20 / 12.85 | 5 | 5 |
2 | 7 | 1524.12 | 40 | 14.62 | 2552 | 1492 | 1.70 / 14.34 | 5 | 6 |
3 | 13 | 1325.88 | 20 | 14.62 | 2271 | 664 | 2.36 / 15.01 | 5 | 6 |
4 | 13 | 636.64 | 20 | 14.78 | 1261 | 373 | 2.73 / 15.38 | 5 | 7 |
5 | 13 | 34.76 | 20 | 14.97 | 362 | 108 | 2.84 / 15.49 | 5 | 5 |
6 | 8 | 0.12 | 285 | 14.92 | 313 | 1331 | 4.17 / 16.82 | 5 | 155 |
Average= | 3.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.76 | 29 | 14.88 | 455 | 196 | 0.20 / 8.75 | 5 | 5 |
2 | 7 | 1522.92 | 41 | 14.62 | 2536 | 1520 | 1.72 / 10.27 | 5 | 8 |
3 | 13 | 1218.88 | 20 | 14.64 | 2110 | 618 | 2.33 / 10.89 | 5 | 6 |
4 | 13 | 549.96 | 20 | 14.81 | 1133 | 336 | 2.67 / 11.22 | 5 | 6 |
5 | 13 | 36.92 | 20 | 14.96 | 366 | 110 | 2.78 / 11.33 | 5 | 5 |
6 | 8 | 0.08 | 285 | 14.92 | 309 | 1314 | 4.09 / 12.65 | 5 | 174 |
Average= | 3.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.00 | 31 | 14.91 | 457 | 211 | 0.21 / 4.66 | 5 | 5 |
2 | 3 | 949.20 | -1 | 15.30 | 0 | 0 | 0.00 / 4.66 | 5 | 5 |
3 | 7 | 1525.60 | 40 | 14.62 | 2539 | 1485 | 1.70 / 6.15 | 5 | 6 |
4 | 13 | 1220.48 | 20 | 14.64 | 2110 | 618 | 2.31 / 6.76 | 5 | 6 |
5 | 13 | 645.04 | 20 | 14.77 | 1274 | 376 | 2.69 / 7.14 | 5 | 7 |
6 | 13 | 35.16 | 20 | 14.96 | 360 | 108 | 2.80 / 7.25 | 5 | 5 |
7 | 8 | 0.08 | 287 | 14.92 | 305 | 1306 | 4.10 / 8.55 | 5 | 151 |
Average= | 2.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.48 | 31 | 15.07 | 445 | 208 | 0.21 / 1.95 | 5 | 6 |
2 | 3 | 943.60 | -1 | 15.30 | 0 | 0 | 0.00 / 1.95 | 5 | 6 |
3 | 7 | 988.60 | 40 | 14.76 | 1761 | 1040 | 1.25 / 2.99 | 6 | 6 |
4 | 13 | 91.44 | 20 | 15.00 | 440 | 132 | 1.38 / 3.13 | 5 | 5 |
5 | 8 | 0.16 | 291 | 14.96 | 304 | 1323 | 2.70 / 4.45 | 5 | 152 |
Average= | 2.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 74.32 | 30 | 15.25 | 402 | 184 | 0.18 / 0.18 | 5 | 6 |
2 | 7 | 87.48 | 40 | 15.23 | 416 | 253 | 0.44 / 0.44 | 6 | 6 |
3 | 13 | 47.24 | 20 | 15.22 | 351 | 107 | 0.54 / 0.54 | 5 | 6 |
4 | 8 | 0.32 | 285 | 15.17 | 278 | 1202 | 1.75 / 1.75 | 5 | 157 |
Average= | 1.75 (KJ/cycle) |