Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.56 | 46 | 10.49 | 429 | 207 | 0.21 / 1415.24 | 7 | 7 |
2 | 3 | 1049.40 | 1 | 7.46 | 1653 | 12 | 0.22 / 1415.25 | 6 | 6 |
3 | 7 | 1038.68 | 40 | 6.98 | 1601 | 447 | 0.67 / 1415.70 | 6 | 11 |
4 | 13 | 965.52 | 20 | 7.26 | 1529 | 222 | 0.89 / 1415.92 | 6 | 14 |
5 | 13 | 889.80 | 20 | 7.67 | 1423 | 218 | 1.11 / 1416.14 | 6 | 19 |
6 | 13 | 793.20 | 20 | 7.91 | 1325 | 210 | 1.32 / 1416.35 | 6 | 21 |
7 | 13 | 493.24 | 20 | 8.96 | 936 | 168 | 1.48 / 1416.52 | 6 | 35 |
8 | 13 | 90.92 | 20 | 10.29 | 423 | 87 | 1.57 / 1416.61 | 6 | 44 |
9 | 13 | 53.80 | 20 | 10.42 | 375 | 78 | 1.65 / 1416.68 | 6 | 44 |
10 | 13 | 33.04 | 20 | 10.51 | 345 | 73 | 1.72 / 1416.76 | 6 | 43 |
11 | 8 | 0.12 | 343 | 10.66 | 291 | 1064 | 2.79 / 1417.82 | 7 | 133 |
Average= | 15.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.44 | 46 | 10.58 | 408 | 199 | 0.20 / 1410.69 | 7 | 7 |
2 | 3 | 1043.68 | 1 | 7.62 | 1618 | 12 | 0.21 / 1410.70 | 6 | 6 |
3 | 7 | 1433.04 | 41 | 5.66 | 2091 | 485 | 0.70 / 1411.18 | 6 | 6 |
4 | 13 | 1433.12 | 20 | 5.93 | 2108 | 250 | 0.95 / 1411.43 | 6 | 6 |
5 | 13 | 1433.16 | 20 | 5.98 | 2110 | 252 | 1.20 / 1411.69 | 6 | 6 |
6 | 13 | 1433.16 | 20 | 5.98 | 2139 | 256 | 1.45 / 1411.94 | 6 | 6 |
7 | 13 | 1410.28 | 20 | 5.99 | 2105 | 252 | 1.71 / 1412.19 | 6 | 7 |
8 | 13 | 1359.28 | 20 | 6.27 | 2052 | 257 | 1.96 / 1412.45 | 6 | 7 |
9 | 13 | 1291.36 | 20 | 6.61 | 1932 | 255 | 2.22 / 1412.71 | 6 | 9 |
10 | 13 | 1217.00 | 20 | 6.77 | 1854 | 251 | 2.47 / 1412.96 | 6 | 11 |
11 | 13 | 1142.68 | 20 | 6.99 | 1772 | 248 | 2.72 / 1413.21 | 6 | 15 |
12 | 13 | 1058.12 | 20 | 7.26 | 1671 | 243 | 2.96 / 1413.45 | 6 | 20 |
13 | 13 | 853.88 | 20 | 7.90 | 1416 | 224 | 3.18 / 1413.67 | 6 | 25 |
14 | 13 | 529.16 | 20 | 8.87 | 1019 | 181 | 3.37 / 1413.85 | 6 | 37 |
15 | 13 | 205.84 | 20 | 9.90 | 602 | 119 | 3.48 / 1413.97 | 6 | 45 |
16 | 13 | 50.88 | 20 | 10.44 | 386 | 81 | 3.56 / 1414.05 | 6 | 47 |
17 | 13 | 28.08 | 20 | 10.53 | 353 | 74 | 3.64 / 1414.13 | 6 | 47 |
18 | 13 | 14.28 | 20 | 10.59 | 332 | 70 | 3.71 / 1414.20 | 6 | 50 |
19 | 8 | 0.12 | 259 | 10.66 | 303 | 837 | 4.55 / 1415.03 | 6 | 69 |
Average= | 15.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.88 | 47 | 10.52 | 419 | 207 | 0.21 / 1408.02 | 7 | 7 |
2 | 7 | 1001.72 | 40 | 7.29 | 1559 | 455 | 0.66 / 1408.48 | 7 | 13 |
3 | 13 | 929.92 | 20 | 7.71 | 1479 | 228 | 0.89 / 1408.70 | 6 | 19 |
4 | 13 | 840.32 | 20 | 7.97 | 1384 | 221 | 1.11 / 1408.92 | 6 | 22 |
5 | 13 | 542.36 | 20 | 8.89 | 1024 | 182 | 1.29 / 1409.11 | 6 | 33 |
6 | 13 | 230.12 | 20 | 9.84 | 630 | 124 | 1.42 / 1409.23 | 6 | 40 |
7 | 13 | 67.84 | 20 | 10.41 | 397 | 83 | 1.50 / 1409.31 | 6 | 44 |
8 | 13 | 42.36 | 20 | 10.51 | 359 | 75 | 1.57 / 1409.39 | 6 | 46 |
9 | 13 | 6.28 | 20 | 10.66 | 304 | 65 | 1.64 / 1409.45 | 6 | 45 |
10 | 8 | 0.04 | 334 | 10.69 | 290 | 1035 | 2.67 / 1410.49 | 7 | 129 |
Average= | 15.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.44 | 47 | 10.58 | 422 | 210 | 0.21 / 1405.35 | 7 | 7 |
2 | 7 | 986.40 | 40 | 7.50 | 1547 | 464 | 0.67 / 1405.82 | 7 | 15 |
3 | 13 | 904.08 | 20 | 7.89 | 1456 | 230 | 0.90 / 1406.05 | 6 | 20 |
4 | 13 | 814.48 | 20 | 8.19 | 1359 | 223 | 1.13 / 1406.27 | 6 | 23 |
5 | 13 | 506.32 | 20 | 9.09 | 967 | 176 | 1.30 / 1406.45 | 6 | 32 |
6 | 13 | 185.12 | 20 | 10.06 | 555 | 112 | 1.41 / 1406.56 | 6 | 43 |
7 | 13 | 46.96 | 20 | 10.52 | 367 | 77 | 1.49 / 1406.63 | 6 | 46 |
8 | 13 | 27.44 | 20 | 10.57 | 343 | 73 | 1.56 / 1406.71 | 6 | 47 |
9 | 13 | 14.08 | 20 | 10.61 | 327 | 69 | 1.63 / 1406.78 | 6 | 49 |
10 | 8 | 0.12 | 329 | 10.69 | 295 | 1038 | 2.67 / 1407.81 | 6 | 141 |
Average= | 16.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.20 | 44 | 10.67 | 429 | 201 | 0.20 / 1402.53 | 7 | 7 |
2 | 3 | 1062.40 | 2 | 8.06 | 1691 | 27 | 0.23 / 1402.56 | 6 | 6 |
3 | 7 | 1049.44 | 41 | 7.54 | 1640 | 507 | 0.74 / 1403.07 | 6 | 16 |
4 | 13 | 978.24 | 20 | 7.87 | 1557 | 245 | 0.98 / 1403.31 | 6 | 20 |
5 | 13 | 888.08 | 20 | 8.16 | 1444 | 236 | 1.22 / 1403.55 | 6 | 23 |
6 | 13 | 685.80 | 20 | 8.73 | 1198 | 209 | 1.43 / 1403.76 | 6 | 32 |
7 | 13 | 274.08 | 20 | 9.89 | 669 | 132 | 1.56 / 1403.89 | 6 | 44 |
8 | 13 | 53.00 | 20 | 10.56 | 380 | 80 | 1.64 / 1403.97 | 6 | 47 |
9 | 13 | 33.76 | 20 | 10.60 | 355 | 75 | 1.71 / 1404.04 | 6 | 47 |
10 | 13 | 4.80 | 20 | 10.71 | 309 | 66 | 1.78 / 1404.11 | 6 | 47 |
11 | 8 | 0.08 | 329 | 10.75 | 292 | 1033 | 2.81 / 1405.14 | 7 | 129 |
Average= | 16.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.16 | 44 | 10.56 | 429 | 199 | 0.20 / 1395.79 | 7 | 7 |
2 | 3 | 1083.16 | 2 | 7.80 | 1711 | 27 | 0.23 / 1395.81 | 6 | 7 |
3 | 7 | 1861.24 | 40 | 4.90 | 2554 | 501 | 0.73 / 1396.31 | 7 | 7 |
4 | 13 | 1861.48 | 20 | 4.95 | 2688 | 266 | 0.99 / 1396.58 | 6 | 6 |
5 | 13 | 1862.08 | 20 | 4.96 | 2738 | 272 | 1.26 / 1396.85 | 6 | 6 |
6 | 13 | 1862.60 | 20 | 5.11 | 2720 | 278 | 1.54 / 1397.13 | 6 | 6 |
7 | 13 | 1863.00 | 20 | 5.17 | 2702 | 279 | 1.82 / 1397.41 | 6 | 6 |
8 | 13 | 1863.28 | 20 | 5.43 | 2630 | 286 | 2.11 / 1397.69 | 6 | 6 |
9 | 13 | 1863.68 | 20 | 5.54 | 2638 | 292 | 2.40 / 1397.99 | 6 | 6 |
10 | 13 | 1863.92 | 20 | 5.48 | 2649 | 290 | 2.69 / 1398.28 | 6 | 6 |
11 | 13 | 1864.20 | 20 | 5.60 | 2632 | 295 | 2.98 / 1398.57 | 6 | 6 |
12 | 13 | 1835.36 | 20 | 5.60 | 2617 | 293 | 3.28 / 1398.86 | 6 | 6 |
13 | 13 | 1791.56 | 20 | 5.85 | 2541 | 297 | 3.58 / 1399.16 | 6 | 6 |
14 | 13 | 1734.72 | 20 | 5.91 | 2496 | 295 | 3.87 / 1399.46 | 6 | 6 |
15 | 13 | 1663.32 | 20 | 6.11 | 2406 | 294 | 4.16 / 1399.75 | 6 | 7 |
16 | 13 | 1588.44 | 20 | 6.42 | 2316 | 297 | 4.46 / 1400.05 | 6 | 9 |
17 | 13 | 1506.48 | 20 | 6.76 | 2182 | 295 | 4.76 / 1400.34 | 6 | 11 |
18 | 13 | 1408.88 | 20 | 6.99 | 2084 | 291 | 5.05 / 1400.63 | 6 | 17 |
19 | 13 | 1215.60 | 20 | 7.39 | 1853 | 274 | 5.32 / 1400.91 | 6 | 25 |
20 | 13 | 1012.64 | 20 | 7.97 | 1623 | 259 | 5.58 / 1401.17 | 6 | 30 |
21 | 13 | 688.52 | 20 | 8.81 | 1222 | 215 | 5.80 / 1401.38 | 6 | 40 |
22 | 13 | 260.52 | 20 | 10.02 | 661 | 132 | 5.93 / 1401.51 | 6 | 50 |
23 | 13 | 78.68 | 20 | 10.51 | 423 | 89 | 6.02 / 1401.60 | 6 | 51 |
24 | 13 | 24.80 | 20 | 10.67 | 343 | 73 | 6.09 / 1401.68 | 6 | 51 |
25 | 8 | 0.12 | 140 | 10.77 | 304 | 458 | 6.55 / 1402.13 | 6 | 61 |
26 | 14 | 0.00 | 60 | 10.75 | 304 | 196 | 6.74 / 1402.33 | 7 | 61 |
Average= | 16.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.60 | 47 | 10.67 | 425 | 213 | 0.21 / 1393.08 | 7 | 7 |
2 | 7 | 977.00 | 40 | 7.78 | 1548 | 482 | 0.69 / 1393.56 | 7 | 19 |
3 | 13 | 901.76 | 20 | 8.23 | 1456 | 240 | 0.93 / 1393.80 | 6 | 25 |
4 | 13 | 804.24 | 20 | 8.52 | 1343 | 229 | 1.16 / 1394.03 | 6 | 28 |
5 | 13 | 603.36 | 20 | 8.98 | 1112 | 200 | 1.36 / 1394.23 | 6 | 34 |
6 | 13 | 169.84 | 20 | 10.19 | 549 | 112 | 1.47 / 1394.34 | 6 | 46 |
7 | 13 | 47.04 | 20 | 10.59 | 370 | 78 | 1.55 / 1394.42 | 6 | 46 |
8 | 13 | 24.56 | 20 | 10.64 | 342 | 73 | 1.63 / 1394.49 | 6 | 47 |
9 | 8 | 0.04 | 343 | 10.73 | 297 | 1093 | 2.72 / 1395.59 | 6 | 134 |
Average= | 16.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.44 | 40 | 10.70 | 440 | 188 | 0.19 / 1390.15 | 7 | 7 |
2 | 10 | 1043.20 | 4 | 8.69 | 1625 | 56 | 0.24 / 1390.21 | 6 | 12 |
3 | 10 | 1071.72 | 3 | 8.49 | 1679 | 43 | 0.29 / 1390.25 | 6 | 10 |
4 | 3 | 1062.00 | 2 | 8.61 | 1664 | 29 | 0.32 / 1390.28 | 6 | 7 |
5 | 7 | 1051.64 | 40 | 8.00 | 1650 | 528 | 0.84 / 1390.81 | 7 | 19 |
6 | 13 | 967.48 | 20 | 8.32 | 1569 | 261 | 1.11 / 1391.07 | 6 | 23 |
7 | 13 | 772.44 | 20 | 8.76 | 1330 | 233 | 1.34 / 1391.30 | 6 | 30 |
8 | 13 | 465.92 | 20 | 9.53 | 943 | 180 | 1.52 / 1391.48 | 6 | 41 |
9 | 13 | 143.32 | 20 | 10.37 | 512 | 106 | 1.62 / 1391.59 | 6 | 48 |
10 | 13 | 73.00 | 20 | 10.56 | 416 | 88 | 1.71 / 1391.68 | 6 | 47 |
11 | 13 | 20.68 | 20 | 10.71 | 340 | 73 | 1.78 / 1391.75 | 6 | 48 |
12 | 8 | 0.08 | 343 | 10.77 | 302 | 1116 | 2.90 / 1392.87 | 6 | 138 |
Average= | 16.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.88 | 36 | 11.18 | 422 | 170 | 0.17 / 1387.05 | 7 | 7 |
2 | 10 | 1023.28 | 5 | 9.67 | 1640 | 79 | 0.25 / 1387.13 | 6 | 16 |
3 | 3 | 1135.68 | 3 | 9.40 | 1809 | 51 | 0.30 / 1387.18 | 6 | 19 |
4 | 7 | 1079.28 | 40 | 8.51 | 1702 | 579 | 0.88 / 1387.76 | 19 | 24 |
5 | 13 | 1003.88 | 20 | 8.64 | 1634 | 282 | 1.16 / 1388.04 | 6 | 27 |
6 | 13 | 910.64 | 20 | 8.85 | 1509 | 267 | 1.43 / 1388.31 | 6 | 30 |
7 | 13 | 593.48 | 20 | 9.49 | 1114 | 211 | 1.64 / 1388.52 | 6 | 42 |
8 | 13 | 274.56 | 20 | 10.22 | 699 | 143 | 1.78 / 1388.66 | 6 | 47 |
9 | 13 | 77.84 | 20 | 10.69 | 430 | 92 | 1.88 / 1388.75 | 6 | 49 |
10 | 13 | 41.84 | 20 | 10.77 | 378 | 81 | 1.96 / 1388.83 | 6 | 51 |
11 | 8 | -0.04 | 339 | 10.82 | 309 | 1133 | 3.09 / 1389.97 | 6 | 136 |
Average= | 16.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.72 | 35 | 11.60 | 428 | 174 | 0.17 / 1379.24 | 7 | 8 |
2 | 10 | 1007.40 | 4 | 9.93 | 1592 | 63 | 0.24 / 1379.30 | 6 | 17 |
3 | 10 | 1044.92 | 3 | 9.70 | 1677 | 49 | 0.29 / 1379.35 | 6 | 17 |
4 | 3 | 1056.92 | 1 | 9.63 | 1689 | 16 | 0.30 / 1379.37 | 6 | 8 |
5 | 7 | 2005.56 | 41 | 4.73 | 1861 | 361 | 0.66 / 1379.73 | 8 | 7 |
6 | 13 | 2065.40 | 20 | 4.92 | 2540 | 250 | 0.91 / 1379.98 | 6 | 7 |
7 | 13 | 2117.88 | 20 | 4.95 | 2730 | 270 | 1.18 / 1380.25 | 6 | 7 |
8 | 13 | 2159.56 | 20 | 5.11 | 2897 | 296 | 1.48 / 1380.55 | 6 | 6 |
9 | 13 | 2196.32 | 20 | 5.26 | 3046 | 320 | 1.80 / 1380.87 | 6 | 6 |
10 | 13 | 2226.56 | 20 | 5.38 | 3168 | 341 | 2.14 / 1381.21 | 6 | 6 |
11 | 13 | 2245.08 | 20 | 5.64 | 3204 | 361 | 2.50 / 1381.57 | 6 | 6 |
12 | 13 | 2237.80 | 20 | 5.91 | 3166 | 374 | 2.88 / 1381.94 | 6 | 6 |
13 | 13 | 2212.72 | 20 | 6.26 | 3114 | 390 | 3.27 / 1382.33 | 6 | 6 |
14 | 13 | 2174.16 | 20 | 6.40 | 3053 | 391 | 3.66 / 1382.72 | 6 | 6 |
15 | 13 | 2120.92 | 20 | 6.59 | 3010 | 397 | 4.05 / 1383.12 | 6 | 6 |
16 | 13 | 2054.00 | 20 | 6.83 | 2911 | 398 | 4.45 / 1383.52 | 6 | 7 |
17 | 13 | 1979.56 | 20 | 7.10 | 2804 | 398 | 4.85 / 1383.92 | 6 | 8 |
18 | 13 | 1902.96 | 20 | 7.34 | 2722 | 400 | 5.25 / 1384.32 | 6 | 11 |
19 | 13 | 1815.56 | 20 | 7.44 | 2621 | 390 | 5.64 / 1384.71 | 6 | 16 |
20 | 13 | 1615.08 | 20 | 7.89 | 2382 | 376 | 6.01 / 1385.08 | 6 | 25 |
21 | 13 | 1317.08 | 20 | 8.46 | 2034 | 344 | 6.36 / 1385.43 | 6 | 36 |
22 | 13 | 910.08 | 20 | 9.33 | 1522 | 284 | 6.64 / 1385.71 | 6 | 46 |
23 | 13 | 500.48 | 20 | 10.16 | 1000 | 203 | 6.85 / 1385.91 | 6 | 53 |
24 | 13 | 191.44 | 20 | 10.80 | 582 | 126 | 6.97 / 1386.04 | 6 | 54 |
25 | 13 | 58.40 | 20 | 11.08 | 395 | 88 | 7.06 / 1386.13 | 6 | 53 |
26 | 13 | 32.00 | 20 | 11.12 | 356 | 79 | 7.14 / 1386.21 | 6 | 53 |
27 | 8 | 0.12 | 139 | 11.14 | 302 | 468 | 7.61 / 1386.67 | 6 | 60 |
28 | 14 | -0.08 | 61 | 11.07 | 301 | 203 | 7.81 / 1386.88 | 7 | 58 |
Average= | 16.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.08 | 39 | 11.98 | 449 | 210 | 0.21 / 1376.40 | 7 | 8 |
2 | 3 | 1035.20 | 1 | 10.19 | 1649 | 17 | 0.23 / 1376.41 | 6 | 6 |
3 | 7 | 1041.16 | 40 | 6.62 | 1600 | 424 | 0.65 / 1376.84 | 6 | 8 |
4 | 13 | 970.24 | 20 | 8.77 | 1554 | 273 | 0.92 / 1377.11 | 6 | 25 |
5 | 13 | 882.64 | 20 | 9.26 | 1462 | 271 | 1.19 / 1377.38 | 6 | 33 |
6 | 13 | 784.60 | 20 | 9.61 | 1335 | 257 | 1.45 / 1377.64 | 6 | 38 |
7 | 13 | 243.28 | 20 | 11.20 | 649 | 145 | 1.60 / 1377.78 | 6 | 54 |
8 | 13 | 69.28 | 20 | 11.66 | 411 | 96 | 1.69 / 1377.88 | 6 | 56 |
9 | 13 | 38.12 | 20 | 11.72 | 365 | 86 | 1.78 / 1377.96 | 6 | 56 |
10 | 13 | 3.48 | 20 | 11.81 | 312 | 74 | 1.85 / 1378.04 | 6 | 59 |
11 | 8 | 0.04 | 298 | 11.56 | 299 | 1030 | 2.88 / 1379.07 | 7 | 138 |
Average= | 17.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.44 | 34 | 12.56 | 437 | 187 | 0.19 / 1373.44 | 7 | 9 |
2 | 10 | 1010.76 | 3 | 11.04 | 1663 | 55 | 0.24 / 1373.49 | 6 | 25 |
3 | 3 | 1066.04 | 2 | 10.71 | 1731 | 37 | 0.28 / 1373.53 | 6 | 12 |
4 | 7 | 1045.92 | 40 | 5.81 | 1597 | 371 | 0.65 / 1373.90 | 12 | 6 |
5 | 13 | 984.20 | 20 | 8.82 | 1587 | 280 | 0.93 / 1374.18 | 6 | 24 |
6 | 13 | 904.32 | 20 | 9.37 | 1509 | 283 | 1.21 / 1374.46 | 6 | 32 |
7 | 13 | 704.88 | 20 | 10.22 | 1258 | 257 | 1.47 / 1374.72 | 6 | 44 |
8 | 13 | 188.88 | 20 | 11.64 | 594 | 138 | 1.61 / 1374.86 | 6 | 58 |
9 | 13 | 62.48 | 20 | 11.99 | 416 | 100 | 1.71 / 1374.96 | 6 | 55 |
10 | 13 | 33.08 | 20 | 12.03 | 369 | 89 | 1.80 / 1375.05 | 6 | 56 |
11 | 8 | 0.04 | 308 | 11.94 | 310 | 1140 | 2.94 / 1376.19 | 7 | 137 |
Average= | 17.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.60 | 34 | 13.21 | 453 | 203 | 0.20 / 1370.57 | 7 | 11 |
2 | 3 | 1081.92 | 2 | 11.87 | 1766 | 42 | 0.25 / 1370.61 | 6 | 24 |
3 | 7 | 1037.00 | 41 | 8.35 | 1627 | 557 | 0.80 / 1371.16 | 24 | 23 |
4 | 13 | 945.44 | 20 | 10.07 | 1573 | 317 | 1.12 / 1371.48 | 6 | 39 |
5 | 13 | 736.88 | 20 | 10.82 | 1313 | 284 | 1.40 / 1371.77 | 6 | 48 |
6 | 13 | 209.04 | 20 | 12.20 | 631 | 154 | 1.56 / 1371.92 | 6 | 62 |
7 | 13 | 66.16 | 20 | 12.56 | 418 | 105 | 1.66 / 1372.02 | 6 | 59 |
8 | 13 | 33.44 | 20 | 12.61 | 371 | 94 | 1.76 / 1372.12 | 6 | 61 |
9 | 8 | 0.16 | 292 | 12.38 | 313 | 1131 | 2.89 / 1373.25 | 7 | 150 |
Average= | 17.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.60 | 34 | 13.55 | 467 | 215 | 0.22 / 1364.57 | 7 | 12 |
2 | 3 | 1039.16 | 1 | 11.65 | 1709 | 20 | 0.24 / 1364.59 | 6 | 7 |
3 | 7 | 1847.52 | 40 | 4.57 | 1177 | 215 | 0.45 / 1364.81 | 7 | 7 |
4 | 13 | 1847.52 | 20 | 5.35 | 2016 | 216 | 0.67 / 1365.02 | 6 | 7 |
5 | 13 | 1847.52 | 20 | 5.73 | 2341 | 268 | 0.93 / 1365.29 | 6 | 7 |
6 | 13 | 1847.76 | 20 | 6.30 | 2594 | 327 | 1.26 / 1365.62 | 6 | 7 |
7 | 13 | 1848.12 | 20 | 7.50 | 2649 | 397 | 1.66 / 1366.02 | 6 | 6 |
8 | 13 | 1845.92 | 20 | 8.09 | 2680 | 434 | 2.09 / 1366.45 | 6 | 10 |
9 | 13 | 1800.48 | 20 | 8.61 | 2638 | 454 | 2.55 / 1366.90 | 6 | 17 |
10 | 13 | 1739.84 | 20 | 9.04 | 2601 | 470 | 3.02 / 1367.37 | 6 | 27 |
11 | 13 | 1660.72 | 20 | 9.51 | 2465 | 469 | 3.49 / 1367.84 | 6 | 35 |
12 | 13 | 1362.88 | 20 | 10.30 | 2134 | 440 | 3.92 / 1368.28 | 6 | 51 |
13 | 13 | 1161.92 | 20 | 10.74 | 1884 | 405 | 4.33 / 1368.69 | 6 | 61 |
14 | 13 | 509.12 | 20 | 12.11 | 1035 | 251 | 4.58 / 1368.94 | 6 | 69 |
15 | 13 | 102.68 | 20 | 12.93 | 487 | 126 | 4.71 / 1369.06 | 6 | 69 |
16 | 13 | 59.00 | 20 | 12.98 | 420 | 109 | 4.82 / 1369.17 | 6 | 70 |
17 | 8 | 0.08 | 291 | 12.69 | 322 | 1189 | 6.00 / 1370.36 | 6 | 140 |
Average= | 17.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.16 | 34 | 13.98 | 458 | 218 | 0.22 / 1361.34 | 7 | 12 |
2 | 7 | 1002.16 | 41 | 4.59 | 1306 | 246 | 0.46 / 1361.59 | 6 | 7 |
3 | 13 | 1008.52 | 20 | 9.39 | 1614 | 303 | 0.77 / 1361.89 | 6 | 18 |
4 | 13 | 961.92 | 20 | 10.14 | 1574 | 319 | 1.09 / 1362.21 | 6 | 34 |
5 | 13 | 878.52 | 20 | 10.80 | 1475 | 319 | 1.40 / 1362.53 | 6 | 43 |
6 | 13 | 780.60 | 20 | 11.30 | 1363 | 308 | 1.71 / 1362.83 | 6 | 50 |
7 | 13 | 199.44 | 20 | 13.18 | 620 | 163 | 1.88 / 1363.00 | 6 | 69 |
8 | 13 | 50.60 | 20 | 13.53 | 422 | 114 | 1.99 / 1363.11 | 6 | 73 |
9 | 13 | 11.12 | 20 | 13.62 | 365 | 99 | 2.09 / 1363.21 | 6 | 68 |
10 | 8 | 0.08 | 256 | 13.21 | 339 | 1146 | 3.24 / 1364.36 | 7 | 135 |
Average= | 17.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.00 | 34 | 14.00 | 459 | 218 | 0.22 / 1358.12 | 7 | 11 |
2 | 7 | 1028.56 | 40 | 4.61 | 1391 | 257 | 0.47 / 1358.37 | 11 | 7 |
3 | 13 | 1022.56 | 20 | 10.10 | 1647 | 333 | 0.81 / 1358.71 | 6 | 29 |
4 | 13 | 950.88 | 20 | 10.77 | 1567 | 338 | 1.15 / 1359.04 | 6 | 42 |
5 | 13 | 856.76 | 20 | 11.31 | 1449 | 328 | 1.47 / 1359.37 | 6 | 50 |
6 | 13 | 646.16 | 20 | 12.27 | 1218 | 299 | 1.77 / 1359.67 | 6 | 61 |
7 | 13 | 101.68 | 20 | 13.81 | 495 | 137 | 1.91 / 1359.81 | 6 | 76 |
8 | 13 | 58.92 | 20 | 13.93 | 436 | 121 | 2.03 / 1359.93 | 6 | 69 |
9 | 8 | 0.12 | 266 | 13.52 | 332 | 1194 | 3.22 / 1361.12 | 7 | 140 |
Average= | 17.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.96 | 34 | 14.09 | 468 | 224 | 0.22 / 1355.15 | 7 | 9 |
2 | 7 | 1004.32 | 40 | 6.76 | 1597 | 432 | 0.66 / 1355.58 | 9 | 13 |
3 | 13 | 942.88 | 20 | 11.38 | 1574 | 358 | 1.01 / 1355.94 | 6 | 47 |
4 | 13 | 751.28 | 20 | 12.27 | 1341 | 329 | 1.34 / 1356.27 | 6 | 55 |
5 | 13 | 333.60 | 20 | 13.31 | 809 | 215 | 1.56 / 1356.49 | 6 | 72 |
6 | 13 | 63.80 | 20 | 13.89 | 447 | 124 | 1.68 / 1356.61 | 6 | 69 |
7 | 13 | 37.84 | 20 | 14.01 | 410 | 115 | 1.80 / 1356.73 | 6 | 71 |
8 | 8 | 0.16 | 256 | 13.58 | 337 | 1172 | 2.97 / 1357.90 | 7 | 142 |
Average= | 18.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.04 | 34 | 14.01 | 465 | 221 | 0.22 / 1348.95 | 7 | 12 |
2 | 7 | 2006.28 | 41 | 4.60 | 1307 | 247 | 0.47 / 1349.20 | 6 | 7 |
3 | 13 | 2054.24 | 20 | 6.35 | 2504 | 318 | 0.79 / 1349.51 | 6 | 7 |
4 | 13 | 2091.92 | 20 | 7.29 | 2908 | 424 | 1.21 / 1349.94 | 6 | 6 |
5 | 13 | 2084.28 | 20 | 8.46 | 2973 | 503 | 1.71 / 1350.44 | 6 | 7 |
6 | 13 | 2036.48 | 20 | 9.09 | 2911 | 529 | 2.24 / 1350.97 | 6 | 16 |
7 | 13 | 1964.64 | 20 | 9.53 | 2860 | 545 | 2.79 / 1351.52 | 6 | 24 |
8 | 13 | 1876.52 | 20 | 9.99 | 2779 | 555 | 3.34 / 1352.07 | 6 | 37 |
9 | 13 | 1677.64 | 20 | 10.87 | 2525 | 549 | 3.89 / 1352.62 | 6 | 54 |
10 | 13 | 1155.20 | 20 | 12.28 | 1891 | 464 | 4.36 / 1353.08 | 6 | 77 |
11 | 13 | 624.20 | 20 | 13.12 | 1206 | 316 | 4.67 / 1353.40 | 6 | 82 |
12 | 13 | 182.32 | 20 | 13.76 | 626 | 172 | 4.84 / 1353.57 | 6 | 81 |
13 | 13 | 46.84 | 20 | 14.07 | 425 | 120 | 4.96 / 1353.69 | 6 | 83 |
14 | 8 | 0.04 | 263 | 13.70 | 343 | 1236 | 6.20 / 1354.93 | 7 | 131 |
Average= | 18.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.16 | 34 | 14.05 | 466 | 223 | 0.22 / 1345.65 | 7 | 11 |
2 | 7 | 1010.52 | 40 | 4.62 | 1428 | 264 | 0.49 / 1345.92 | 6 | 7 |
3 | 13 | 1017.12 | 20 | 11.08 | 1666 | 369 | 0.86 / 1346.29 | 6 | 42 |
4 | 13 | 953.92 | 20 | 11.30 | 1595 | 360 | 1.22 / 1346.65 | 6 | 51 |
5 | 13 | 861.04 | 20 | 11.76 | 1500 | 353 | 1.57 / 1347.00 | 6 | 54 |
6 | 13 | 539.00 | 20 | 12.88 | 1091 | 281 | 1.85 / 1347.28 | 6 | 71 |
7 | 13 | 95.16 | 20 | 13.81 | 491 | 136 | 1.99 / 1347.42 | 6 | 74 |
8 | 13 | 26.68 | 20 | 14.07 | 386 | 109 | 2.09 / 1347.53 | 6 | 73 |
9 | 8 | 0.08 | 259 | 13.70 | 339 | 1203 | 3.30 / 1348.73 | 7 | 140 |
Average= | 18.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.76 | 34 | 14.18 | 466 | 225 | 0.22 / 1342.44 | 7 | 11 |
2 | 7 | 1015.52 | 40 | 4.96 | 1524 | 302 | 0.53 / 1342.74 | 11 | 6 |
3 | 13 | 981.24 | 20 | 11.41 | 1621 | 370 | 0.90 / 1343.11 | 6 | 48 |
4 | 13 | 912.40 | 20 | 11.64 | 1540 | 359 | 1.26 / 1343.47 | 6 | 55 |
5 | 13 | 813.76 | 20 | 12.09 | 1431 | 346 | 1.60 / 1343.81 | 6 | 58 |
6 | 13 | 264.40 | 20 | 13.54 | 726 | 197 | 1.80 / 1344.01 | 6 | 76 |
7 | 13 | 78.92 | 20 | 13.95 | 468 | 131 | 1.93 / 1344.14 | 6 | 78 |
8 | 13 | 41.48 | 20 | 14.08 | 410 | 115 | 2.04 / 1344.25 | 6 | 70 |
9 | 8 | 0.12 | 249 | 13.85 | 341 | 1176 | 3.22 / 1345.43 | 7 | 137 |
Average= | 18.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.92 | 34 | 14.19 | 470 | 227 | 0.23 / 1339.40 | 7 | 10 |
2 | 7 | 1003.84 | 40 | 7.07 | 1557 | 440 | 0.67 / 1339.84 | 6 | 15 |
3 | 13 | 936.24 | 20 | 11.97 | 1567 | 375 | 1.04 / 1340.22 | 6 | 54 |
4 | 13 | 839.48 | 20 | 12.26 | 1446 | 355 | 1.40 / 1340.57 | 6 | 59 |
5 | 13 | 290.32 | 20 | 13.60 | 750 | 204 | 1.60 / 1340.78 | 6 | 74 |
6 | 13 | 95.16 | 20 | 13.94 | 496 | 138 | 1.74 / 1340.92 | 6 | 72 |
7 | 13 | 27.64 | 20 | 14.13 | 389 | 110 | 1.85 / 1341.03 | 6 | 69 |
8 | 8 | 0.12 | 249 | 13.99 | 340 | 1184 | 3.03 / 1342.21 | 7 | 139 |
Average= | 18.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.88 | 34 | 14.15 | 473 | 228 | 0.23 / 1333.15 | 7 | 12 |
2 | 7 | 2002.72 | 41 | 4.57 | 1201 | 225 | 0.45 / 1333.38 | 12 | 7 |
3 | 13 | 2055.84 | 20 | 6.12 | 2418 | 296 | 0.75 / 1333.67 | 6 | 7 |
4 | 13 | 2094.88 | 20 | 7.35 | 2839 | 417 | 1.17 / 1334.09 | 6 | 6 |
5 | 13 | 2091.76 | 20 | 8.61 | 2986 | 514 | 1.68 / 1334.61 | 6 | 7 |
6 | 13 | 2040.64 | 20 | 9.34 | 2940 | 549 | 2.23 / 1335.15 | 6 | 18 |
7 | 13 | 1964.20 | 20 | 9.97 | 2895 | 577 | 2.81 / 1335.73 | 6 | 30 |
8 | 13 | 1884.04 | 20 | 10.56 | 2779 | 587 | 3.39 / 1336.32 | 6 | 41 |
9 | 13 | 1786.28 | 20 | 11.00 | 2684 | 590 | 3.98 / 1336.91 | 6 | 52 |
10 | 13 | 1135.44 | 20 | 12.46 | 1873 | 467 | 4.45 / 1337.38 | 6 | 79 |
11 | 13 | 496.32 | 20 | 13.45 | 1041 | 280 | 4.73 / 1337.66 | 6 | 84 |
12 | 13 | 104.44 | 20 | 14.00 | 518 | 145 | 4.88 / 1337.80 | 6 | 73 |
13 | 13 | 61.48 | 20 | 14.13 | 449 | 127 | 5.00 / 1337.93 | 6 | 76 |
14 | 13 | 15.08 | 20 | 14.25 | 371 | 106 | 5.11 / 1338.03 | 6 | 69 |
15 | 8 | 0.16 | 238 | 14.05 | 342 | 1144 | 6.25 / 1339.18 | 7 | 137 |
Average= | 19.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.00 | 34 | 14.23 | 458 | 222 | 0.22 / 1329.92 | 7 | 10 |
2 | 7 | 1003.76 | 40 | 4.60 | 1336 | 246 | 0.47 / 1330.17 | 10 | 7 |
3 | 13 | 1004.92 | 20 | 11.17 | 1647 | 368 | 0.84 / 1330.54 | 6 | 41 |
4 | 13 | 939.24 | 20 | 11.49 | 1564 | 359 | 1.19 / 1330.90 | 6 | 49 |
5 | 13 | 843.52 | 20 | 11.95 | 1451 | 347 | 1.54 / 1331.24 | 6 | 53 |
6 | 13 | 411.04 | 20 | 13.37 | 911 | 244 | 1.79 / 1331.49 | 6 | 72 |
7 | 13 | 98.28 | 20 | 14.00 | 498 | 139 | 1.92 / 1331.63 | 6 | 78 |
8 | 13 | 26.44 | 20 | 14.17 | 390 | 111 | 2.04 / 1331.74 | 6 | 74 |
9 | 13 | 13.56 | 20 | 14.16 | 372 | 105 | 2.14 / 1331.84 | 7 | 71 |
10 | 8 | 0.12 | 228 | 14.03 | 339 | 1084 | 3.22 / 1332.93 | 7 | 129 |
Average= | 19.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.44 | 34 | 14.23 | 446 | 216 | 0.22 / 1326.66 | 7 | 11 |
2 | 7 | 1005.48 | 41 | 4.63 | 1442 | 274 | 0.49 / 1326.93 | 11 | 7 |
3 | 13 | 1008.48 | 20 | 11.48 | 1652 | 379 | 0.87 / 1327.31 | 6 | 46 |
4 | 13 | 940.88 | 20 | 11.74 | 1568 | 368 | 1.24 / 1327.68 | 6 | 52 |
5 | 13 | 846.48 | 20 | 12.14 | 1479 | 359 | 1.60 / 1328.04 | 6 | 57 |
6 | 13 | 405.68 | 20 | 13.44 | 910 | 245 | 1.84 / 1328.28 | 6 | 76 |
7 | 13 | 84.56 | 20 | 14.05 | 481 | 135 | 1.98 / 1328.42 | 6 | 77 |
8 | 13 | 8.40 | 20 | 14.22 | 364 | 104 | 2.08 / 1328.52 | 6 | 72 |
9 | 8 | 0.12 | 246 | 14.04 | 342 | 1181 | 3.26 / 1329.70 | 7 | 134 |
Average= | 19.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.36 | 34 | 14.22 | 467 | 226 | 0.23 / 1323.72 | 7 | 9 |
2 | 7 | 1008.36 | 41 | 6.39 | 1538 | 403 | 0.63 / 1324.13 | 9 | 10 |
3 | 13 | 946.92 | 20 | 12.03 | 1580 | 380 | 1.01 / 1324.51 | 6 | 52 |
4 | 13 | 653.80 | 20 | 12.94 | 1228 | 318 | 1.33 / 1324.83 | 6 | 65 |
5 | 13 | 237.08 | 20 | 13.79 | 686 | 189 | 1.52 / 1325.02 | 6 | 77 |
6 | 13 | 73.48 | 20 | 14.09 | 462 | 130 | 1.65 / 1325.15 | 6 | 72 |
7 | 13 | 37.52 | 20 | 14.20 | 405 | 115 | 1.76 / 1325.26 | 6 | 71 |
8 | 8 | 0.08 | 245 | 14.08 | 342 | 1180 | 2.94 / 1326.44 | 7 | 135 |
Average= | 19.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.16 | 34 | 14.18 | 463 | 223 | 0.22 / 1317.63 | 7 | 12 |
2 | 7 | 2003.08 | 40 | 4.56 | 1179 | 215 | 0.44 / 1317.84 | 12 | 7 |
3 | 13 | 2056.36 | 20 | 6.28 | 2439 | 306 | 0.74 / 1318.15 | 6 | 7 |
4 | 13 | 2096.04 | 20 | 7.67 | 2929 | 449 | 1.19 / 1318.60 | 6 | 6 |
5 | 13 | 2084.72 | 20 | 9.11 | 2987 | 544 | 1.74 / 1319.14 | 6 | 9 |
6 | 13 | 2042.16 | 20 | 9.75 | 2949 | 575 | 2.31 / 1319.72 | 6 | 22 |
7 | 13 | 1974.12 | 20 | 10.28 | 2895 | 595 | 2.91 / 1320.31 | 6 | 34 |
8 | 13 | 1881.64 | 20 | 10.84 | 2790 | 605 | 3.51 / 1320.92 | 6 | 45 |
9 | 13 | 1354.40 | 20 | 12.22 | 2164 | 529 | 4.04 / 1321.45 | 6 | 75 |
10 | 13 | 849.92 | 20 | 13.07 | 1492 | 390 | 4.43 / 1321.84 | 6 | 74 |
11 | 13 | 327.00 | 20 | 13.76 | 817 | 225 | 4.66 / 1322.06 | 6 | 78 |
12 | 13 | 105.76 | 20 | 14.09 | 519 | 146 | 4.80 / 1322.21 | 6 | 79 |
13 | 13 | 11.00 | 20 | 14.27 | 371 | 106 | 4.91 / 1322.31 | 6 | 74 |
14 | 8 | 0.08 | 242 | 14.11 | 347 | 1185 | 6.09 / 1323.50 | 7 | 129 |
Average= | 20.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.92 | 34 | 14.21 | 459 | 222 | 0.22 / 1314.44 | 7 | 12 |
2 | 7 | 1003.12 | 40 | 4.59 | 1300 | 239 | 0.46 / 1314.68 | 12 | 7 |
3 | 13 | 995.28 | 20 | 11.29 | 1635 | 369 | 0.83 / 1315.05 | 6 | 41 |
4 | 13 | 918.32 | 20 | 11.69 | 1539 | 360 | 1.19 / 1315.41 | 6 | 50 |
5 | 13 | 831.08 | 20 | 12.15 | 1432 | 348 | 1.54 / 1315.76 | 6 | 55 |
6 | 13 | 277.24 | 20 | 13.68 | 740 | 202 | 1.74 / 1315.96 | 6 | 72 |
7 | 13 | 86.48 | 20 | 14.05 | 488 | 137 | 1.88 / 1316.10 | 6 | 69 |
8 | 13 | 21.92 | 20 | 14.19 | 389 | 110 | 1.99 / 1316.21 | 6 | 69 |
9 | 8 | 0.08 | 246 | 14.08 | 346 | 1198 | 3.19 / 1317.41 | 7 | 131 |
Average= | 20.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.72 | 34 | 14.23 | 461 | 223 | 0.22 / 1311.22 | 7 | 9 |
2 | 7 | 998.68 | 41 | 4.61 | 1412 | 267 | 0.49 / 1311.48 | 9 | 7 |
3 | 13 | 1003.24 | 20 | 11.60 | 1641 | 381 | 0.87 / 1311.86 | 6 | 45 |
4 | 13 | 929.32 | 20 | 11.83 | 1551 | 367 | 1.24 / 1312.23 | 6 | 53 |
5 | 13 | 738.64 | 20 | 12.67 | 1323 | 335 | 1.57 / 1312.57 | 6 | 62 |
6 | 13 | 312.68 | 20 | 13.68 | 784 | 215 | 1.79 / 1312.78 | 6 | 71 |
7 | 13 | 102.20 | 20 | 14.05 | 504 | 142 | 1.93 / 1312.92 | 6 | 73 |
8 | 13 | 25.20 | 20 | 14.21 | 382 | 109 | 2.04 / 1313.03 | 6 | 70 |
9 | 8 | 0.08 | 247 | 14.11 | 341 | 1188 | 3.23 / 1314.22 | 7 | 138 |
Average= | 20.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.00 | 34 | 14.21 | 462 | 223 | 0.22 / 1308.23 | 7 | 10 |
2 | 7 | 990.08 | 40 | 5.84 | 1535 | 359 | 0.58 / 1308.58 | 10 | 8 |
3 | 13 | 929.60 | 20 | 12.16 | 1557 | 379 | 0.96 / 1308.96 | 6 | 54 |
4 | 13 | 844.88 | 20 | 12.37 | 1456 | 360 | 1.32 / 1309.32 | 6 | 57 |
5 | 13 | 339.68 | 20 | 13.65 | 823 | 225 | 1.55 / 1309.55 | 6 | 75 |
6 | 13 | 82.20 | 20 | 14.11 | 468 | 132 | 1.68 / 1309.68 | 6 | 68 |
7 | 13 | 46.52 | 20 | 14.19 | 414 | 117 | 1.79 / 1309.80 | 6 | 68 |
8 | 8 | 0.12 | 249 | 14.16 | 339 | 1195 | 2.99 / 1310.99 | 7 | 137 |
Average= | 20.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.00 | 34 | 14.22 | 459 | 222 | 0.22 / 1302.23 | 7 | 12 |
2 | 7 | 2004.68 | 40 | 4.58 | 1217 | 223 | 0.44 / 1302.45 | 12 | 7 |
3 | 13 | 2057.32 | 20 | 6.61 | 2518 | 333 | 0.78 / 1302.78 | 6 | 7 |
4 | 13 | 2096.12 | 20 | 8.33 | 2957 | 493 | 1.27 / 1303.28 | 6 | 6 |
5 | 13 | 2069.60 | 20 | 9.53 | 2977 | 567 | 1.84 / 1303.84 | 6 | 16 |
6 | 13 | 2006.88 | 20 | 10.14 | 2902 | 589 | 2.43 / 1304.43 | 6 | 29 |
7 | 13 | 1923.04 | 20 | 10.68 | 2829 | 604 | 3.03 / 1305.04 | 6 | 40 |
8 | 13 | 1721.00 | 20 | 11.47 | 2609 | 599 | 3.63 / 1305.64 | 6 | 59 |
9 | 13 | 1194.40 | 20 | 12.61 | 1952 | 492 | 4.12 / 1306.13 | 6 | 82 |
10 | 13 | 784.52 | 20 | 13.22 | 1412 | 373 | 4.49 / 1306.50 | 6 | 84 |
11 | 13 | 139.08 | 20 | 14.03 | 554 | 155 | 4.65 / 1306.66 | 6 | 78 |
12 | 13 | 75.36 | 20 | 14.16 | 462 | 131 | 4.78 / 1306.79 | 6 | 73 |
13 | 8 | 0.04 | 256 | 14.18 | 335 | 1216 | 6.00 / 1308.00 | 7 | 134 |
Average= | 21.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.52 | 34 | 14.17 | 476 | 229 | 0.23 / 1299.07 | 7 | 13 |
2 | 7 | 998.76 | 41 | 4.59 | 1297 | 244 | 0.47 / 1299.31 | 13 | 7 |
3 | 13 | 1000.44 | 20 | 11.57 | 1645 | 381 | 0.85 / 1299.69 | 6 | 45 |
4 | 13 | 936.44 | 20 | 11.83 | 1570 | 371 | 1.23 / 1300.06 | 6 | 50 |
5 | 13 | 839.32 | 20 | 12.24 | 1464 | 358 | 1.58 / 1300.42 | 6 | 55 |
6 | 13 | 219.04 | 20 | 13.84 | 667 | 185 | 1.77 / 1300.61 | 6 | 73 |
7 | 13 | 63.40 | 20 | 14.11 | 448 | 126 | 1.89 / 1300.73 | 6 | 72 |
8 | 13 | 16.28 | 20 | 14.20 | 375 | 106 | 2.00 / 1300.84 | 6 | 65 |
9 | 8 | 0.16 | 244 | 14.10 | 339 | 1166 | 3.17 / 1302.01 | 7 | 131 |
Average= | 21.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.52 | 34 | 14.22 | 451 | 218 | 0.22 / 1295.81 | 7 | 13 |
2 | 7 | 999.28 | 40 | 4.61 | 1399 | 258 | 0.48 / 1296.06 | 13 | 7 |
3 | 13 | 998.04 | 20 | 11.79 | 1634 | 385 | 0.86 / 1296.45 | 6 | 47 |
4 | 13 | 934.32 | 20 | 11.96 | 1565 | 374 | 1.24 / 1296.82 | 6 | 52 |
5 | 13 | 839.88 | 20 | 12.38 | 1438 | 356 | 1.59 / 1297.18 | 6 | 59 |
6 | 13 | 395.04 | 20 | 13.58 | 888 | 241 | 1.83 / 1297.42 | 6 | 70 |
7 | 13 | 82.40 | 20 | 14.08 | 471 | 133 | 1.97 / 1297.55 | 6 | 72 |
8 | 13 | 41.72 | 20 | 14.15 | 410 | 116 | 2.08 / 1297.67 | 6 | 76 |
9 | 8 | 0.12 | 242 | 14.11 | 342 | 1168 | 3.25 / 1298.84 | 7 | 133 |
Average= | 21.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.92 | 34 | 14.23 | 467 | 226 | 0.23 / 1292.77 | 7 | 11 |
2 | 7 | 991.52 | 41 | 5.71 | 1520 | 356 | 0.58 / 1293.13 | 11 | 8 |
3 | 13 | 940.92 | 20 | 12.29 | 1581 | 389 | 0.97 / 1293.52 | 6 | 56 |
4 | 13 | 851.16 | 20 | 12.51 | 1471 | 368 | 1.34 / 1293.88 | 6 | 60 |
5 | 13 | 425.64 | 20 | 13.55 | 937 | 254 | 1.59 / 1294.14 | 6 | 72 |
6 | 13 | 100.72 | 20 | 14.07 | 503 | 142 | 1.73 / 1294.28 | 6 | 77 |
7 | 13 | 50.48 | 20 | 14.14 | 425 | 120 | 1.85 / 1294.40 | 6 | 75 |
8 | 8 | 0.12 | 249 | 14.14 | 338 | 1190 | 3.04 / 1295.59 | 7 | 136 |
Average= | 21.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.24 | 34 | 14.14 | 472 | 227 | 0.23 / 1286.71 | 7 | 11 |
2 | 7 | 2009.40 | 40 | 4.56 | 1154 | 210 | 0.44 / 1286.92 | 11 | 7 |
3 | 13 | 2061.72 | 20 | 6.49 | 2499 | 324 | 0.76 / 1287.24 | 6 | 7 |
4 | 13 | 2098.52 | 20 | 8.32 | 2994 | 498 | 1.26 / 1287.74 | 6 | 6 |
5 | 13 | 2067.72 | 20 | 9.85 | 2955 | 582 | 1.84 / 1288.32 | 6 | 17 |
6 | 13 | 2001.04 | 20 | 10.37 | 2902 | 602 | 2.44 / 1288.92 | 6 | 31 |
7 | 13 | 1927.16 | 20 | 10.84 | 2832 | 614 | 3.06 / 1289.54 | 6 | 42 |
8 | 13 | 1839.52 | 20 | 11.20 | 2744 | 615 | 3.67 / 1290.15 | 6 | 52 |
9 | 13 | 1307.72 | 20 | 12.50 | 2093 | 523 | 4.20 / 1290.68 | 6 | 78 |
10 | 13 | 671.56 | 20 | 13.36 | 1273 | 340 | 4.54 / 1291.02 | 6 | 85 |
11 | 13 | 126.84 | 20 | 14.02 | 550 | 154 | 4.69 / 1291.17 | 6 | 78 |
12 | 13 | 63.48 | 20 | 14.13 | 460 | 130 | 4.82 / 1291.30 | 6 | 81 |
13 | 8 | 0.08 | 254 | 14.12 | 347 | 1245 | 6.06 / 1292.54 | 7 | 132 |
Average= | 22.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.16 | 34 | 14.15 | 475 | 229 | 0.23 / 1283.47 | 7 | 11 |
2 | 7 | 1004.04 | 41 | 4.58 | 1286 | 241 | 0.47 / 1283.71 | 11 | 7 |
3 | 13 | 1004.16 | 20 | 11.70 | 1647 | 385 | 0.86 / 1284.10 | 6 | 47 |
4 | 13 | 939.48 | 20 | 11.97 | 1565 | 375 | 1.23 / 1284.47 | 6 | 52 |
5 | 13 | 847.24 | 20 | 12.34 | 1459 | 360 | 1.59 / 1284.83 | 6 | 58 |
6 | 13 | 406.72 | 20 | 13.56 | 906 | 246 | 1.84 / 1285.08 | 6 | 75 |
7 | 13 | 82.52 | 20 | 14.06 | 472 | 133 | 1.97 / 1285.21 | 6 | 76 |
8 | 13 | 20.84 | 20 | 14.15 | 379 | 107 | 2.08 / 1285.32 | 6 | 72 |
9 | 8 | 0.12 | 242 | 14.11 | 341 | 1164 | 3.24 / 1286.48 | 7 | 129 |
Average= | 22.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.00 | 34 | 14.18 | 460 | 222 | 0.22 / 1280.20 | 7 | 12 |
2 | 7 | 1004.28 | 40 | 4.60 | 1346 | 248 | 0.47 / 1280.44 | 12 | 7 |
3 | 13 | 997.84 | 20 | 11.78 | 1642 | 387 | 0.86 / 1280.83 | 6 | 49 |
4 | 13 | 926.16 | 20 | 12.01 | 1551 | 373 | 1.23 / 1281.20 | 6 | 56 |
5 | 13 | 828.24 | 20 | 12.41 | 1427 | 354 | 1.58 / 1281.56 | 6 | 60 |
6 | 13 | 392.80 | 20 | 13.61 | 882 | 240 | 1.82 / 1281.80 | 6 | 75 |
7 | 13 | 77.44 | 20 | 14.08 | 470 | 132 | 1.96 / 1281.93 | 6 | 74 |
8 | 13 | 41.04 | 20 | 14.12 | 410 | 116 | 2.07 / 1282.04 | 6 | 74 |
9 | 8 | 0.16 | 245 | 14.10 | 346 | 1195 | 3.27 / 1283.24 | 7 | 133 |
Average= | 22.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.96 | 34 | 14.20 | 466 | 225 | 0.22 / 1277.18 | 7 | 9 |
2 | 7 | 1000.24 | 41 | 5.30 | 1478 | 321 | 0.55 / 1277.50 | 9 | 6 |
3 | 13 | 947.88 | 20 | 12.32 | 1585 | 391 | 0.94 / 1277.89 | 6 | 56 |
4 | 13 | 861.92 | 20 | 12.54 | 1486 | 373 | 1.31 / 1278.27 | 6 | 60 |
5 | 13 | 438.80 | 20 | 13.58 | 935 | 254 | 1.56 / 1278.52 | 6 | 73 |
6 | 13 | 117.20 | 20 | 14.03 | 523 | 147 | 1.71 / 1278.67 | 6 | 74 |
7 | 13 | 59.60 | 20 | 14.12 | 430 | 121 | 1.83 / 1278.79 | 6 | 73 |
8 | 8 | 0.08 | 249 | 14.15 | 336 | 1184 | 3.02 / 1279.97 | 7 | 137 |
Average= | 23.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.56 | 34 | 14.16 | 454 | 219 | 0.22 / 1271.22 | 7 | 12 |
2 | 7 | 2002.72 | 41 | 4.58 | 1229 | 231 | 0.45 / 1271.45 | 12 | 7 |
3 | 13 | 2060.68 | 20 | 6.93 | 2612 | 362 | 0.81 / 1271.81 | 6 | 7 |
4 | 13 | 2097.72 | 20 | 9.11 | 3000 | 547 | 1.36 / 1272.36 | 6 | 7 |
5 | 13 | 2057.24 | 20 | 10.11 | 2984 | 603 | 1.96 / 1272.96 | 6 | 24 |
6 | 13 | 1981.96 | 20 | 10.59 | 2909 | 616 | 2.58 / 1273.58 | 6 | 35 |
7 | 13 | 1886.40 | 20 | 11.10 | 2807 | 623 | 3.20 / 1274.20 | 6 | 47 |
8 | 13 | 1584.64 | 20 | 12.09 | 2428 | 587 | 3.79 / 1274.79 | 6 | 68 |
9 | 13 | 1153.76 | 20 | 12.80 | 1890 | 484 | 4.27 / 1275.27 | 6 | 84 |
10 | 13 | 385.80 | 20 | 13.72 | 882 | 242 | 4.51 / 1275.51 | 6 | 81 |
11 | 13 | 90.44 | 20 | 14.09 | 484 | 136 | 4.65 / 1275.65 | 6 | 75 |
12 | 13 | 25.32 | 20 | 14.20 | 382 | 108 | 4.76 / 1275.76 | 6 | 72 |
13 | 8 | 0.16 | 249 | 14.14 | 341 | 1201 | 5.96 / 1276.96 | 7 | 135 |
Average= | 23.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.36 | 34 | 14.13 | 469 | 225 | 0.23 / 1268.08 | 7 | 11 |
2 | 7 | 1007.92 | 41 | 4.58 | 1268 | 238 | 0.46 / 1268.31 | 11 | 7 |
3 | 13 | 1006.20 | 20 | 11.81 | 1657 | 391 | 0.85 / 1268.71 | 6 | 48 |
4 | 13 | 941.20 | 20 | 12.05 | 1575 | 380 | 1.23 / 1269.08 | 6 | 54 |
5 | 13 | 845.20 | 20 | 12.45 | 1451 | 361 | 1.60 / 1269.45 | 6 | 59 |
6 | 13 | 198.88 | 20 | 13.87 | 625 | 173 | 1.77 / 1269.62 | 6 | 76 |
7 | 13 | 52.60 | 20 | 14.11 | 420 | 119 | 1.89 / 1269.74 | 6 | 73 |
8 | 8 | 0.12 | 263 | 14.10 | 340 | 1261 | 3.15 / 1271.00 | 7 | 132 |
Average= | 23.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.52 | 34 | 14.16 | 455 | 219 | 0.22 / 1264.95 | 7 | 11 |
2 | 7 | 993.60 | 40 | 4.59 | 1298 | 238 | 0.46 / 1265.19 | 11 | 7 |
3 | 13 | 995.60 | 20 | 11.89 | 1639 | 390 | 0.85 / 1265.58 | 6 | 50 |
4 | 13 | 936.40 | 20 | 12.12 | 1561 | 378 | 1.23 / 1265.96 | 6 | 54 |
5 | 13 | 643.00 | 20 | 13.15 | 1209 | 318 | 1.54 / 1266.28 | 6 | 70 |
6 | 13 | 230.28 | 20 | 13.85 | 676 | 187 | 1.73 / 1266.47 | 6 | 74 |
7 | 13 | 64.48 | 20 | 14.08 | 449 | 126 | 1.86 / 1266.59 | 6 | 72 |
8 | 8 | 0.16 | 261 | 14.10 | 342 | 1259 | 3.12 / 1267.85 | 7 | 140 |
Average= | 24.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.76 | 34 | 14.19 | 466 | 225 | 0.22 / 1261.94 | 7 | 11 |
2 | 7 | 1004.28 | 41 | 5.28 | 1469 | 318 | 0.54 / 1262.26 | 6 | 6 |
3 | 13 | 957.24 | 20 | 12.41 | 1599 | 397 | 0.94 / 1262.66 | 6 | 56 |
4 | 13 | 871.36 | 20 | 12.69 | 1491 | 378 | 1.32 / 1263.04 | 6 | 60 |
5 | 13 | 455.08 | 20 | 13.60 | 952 | 259 | 1.58 / 1263.30 | 6 | 72 |
6 | 13 | 119.04 | 20 | 14.02 | 526 | 147 | 1.72 / 1263.44 | 6 | 77 |
7 | 13 | 30.00 | 20 | 14.15 | 392 | 111 | 1.84 / 1263.55 | 6 | 71 |
8 | 8 | 0.12 | 246 | 14.11 | 340 | 1180 | 3.02 / 1264.73 | 6 | 132 |
Average= | 24.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.12 | 34 | 14.15 | 453 | 218 | 0.22 / 1255.95 | 7 | 11 |
2 | 7 | 2007.44 | 40 | 4.57 | 1197 | 219 | 0.44 / 1256.17 | 11 | 7 |
3 | 13 | 2060.20 | 20 | 7.00 | 2600 | 364 | 0.80 / 1256.54 | 6 | 7 |
4 | 13 | 2091.08 | 20 | 9.45 | 2995 | 566 | 1.37 / 1257.10 | 6 | 9 |
5 | 13 | 2052.08 | 20 | 10.26 | 2980 | 611 | 1.98 / 1257.71 | 6 | 27 |
6 | 13 | 1984.40 | 20 | 10.72 | 2907 | 623 | 2.60 / 1258.34 | 6 | 37 |
7 | 13 | 1894.84 | 20 | 11.23 | 2798 | 628 | 3.23 / 1258.96 | 6 | 48 |
8 | 13 | 1478.88 | 20 | 12.38 | 2291 | 567 | 3.80 / 1259.53 | 6 | 73 |
9 | 13 | 1055.48 | 20 | 12.96 | 1764 | 457 | 4.25 / 1259.99 | 6 | 82 |
10 | 13 | 500.32 | 20 | 13.60 | 1033 | 281 | 4.54 / 1260.27 | 6 | 85 |
11 | 13 | 74.40 | 20 | 14.08 | 472 | 133 | 4.67 / 1260.40 | 6 | 77 |
12 | 13 | 21.52 | 20 | 14.15 | 394 | 112 | 4.78 / 1260.51 | 6 | 74 |
13 | 13 | 8.72 | 20 | 14.12 | 371 | 105 | 4.88 / 1260.62 | 6 | 78 |
14 | 8 | 0.08 | 225 | 14.09 | 347 | 1100 | 5.98 / 1261.72 | 7 | 135 |
Average= | 25.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.24 | 34 | 14.11 | 460 | 221 | 0.22 / 1252.84 | 7 | 12 |
2 | 7 | 1010.76 | 40 | 4.57 | 1228 | 224 | 0.45 / 1253.07 | 12 | 7 |
3 | 13 | 1003.80 | 20 | 11.89 | 1650 | 392 | 0.84 / 1253.46 | 6 | 49 |
4 | 13 | 935.48 | 20 | 12.16 | 1565 | 381 | 1.22 / 1253.84 | 6 | 56 |
5 | 13 | 843.92 | 20 | 12.44 | 1485 | 369 | 1.59 / 1254.21 | 6 | 61 |
6 | 13 | 202.24 | 20 | 13.86 | 640 | 177 | 1.77 / 1254.39 | 6 | 75 |
7 | 13 | 56.48 | 20 | 14.09 | 426 | 120 | 1.89 / 1254.51 | 6 | 74 |
8 | 8 | 0.16 | 263 | 14.10 | 331 | 1227 | 3.11 / 1255.73 | 6 | 135 |
Average= | 25.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.36 | 34 | 14.12 | 472 | 227 | 0.23 / 1249.78 | 7 | 14 |
2 | 7 | 999.48 | 40 | 4.57 | 1227 | 224 | 0.45 / 1250.00 | 14 | 7 |
3 | 13 | 998.04 | 20 | 11.90 | 1648 | 392 | 0.84 / 1250.40 | 6 | 50 |
4 | 13 | 929.24 | 20 | 12.15 | 1562 | 380 | 1.22 / 1250.78 | 6 | 57 |
5 | 13 | 638.88 | 20 | 13.18 | 1223 | 322 | 1.55 / 1251.10 | 6 | 71 |
6 | 13 | 205.80 | 20 | 13.86 | 648 | 180 | 1.72 / 1251.28 | 6 | 76 |
7 | 13 | 54.16 | 20 | 14.09 | 431 | 121 | 1.85 / 1251.40 | 6 | 77 |
8 | 8 | 0.12 | 258 | 14.10 | 336 | 1222 | 3.07 / 1252.62 | 6 | 132 |
Average= | 26.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.40 | 34 | 14.15 | 462 | 222 | 0.22 / 1246.60 | 7 | 11 |
2 | 7 | 1007.84 | 41 | 4.79 | 1419 | 279 | 0.50 / 1246.88 | 11 | 6 |
3 | 13 | 975.72 | 20 | 12.38 | 1622 | 402 | 0.90 / 1247.28 | 6 | 56 |
4 | 13 | 892.56 | 20 | 12.65 | 1521 | 385 | 1.29 / 1247.67 | 6 | 66 |
5 | 13 | 693.88 | 20 | 13.20 | 1292 | 341 | 1.63 / 1248.01 | 6 | 72 |
6 | 13 | 128.08 | 20 | 13.99 | 546 | 153 | 1.78 / 1248.16 | 6 | 80 |
7 | 13 | 39.68 | 20 | 14.12 | 412 | 116 | 1.90 / 1248.28 | 6 | 74 |
8 | 8 | 0.12 | 262 | 14.07 | 346 | 1275 | 3.17 / 1249.55 | 6 | 132 |
Average= | 26.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.36 | 34 | 14.15 | 449 | 216 | 0.22 / 1240.67 | 7 | 12 |
2 | 7 | 2002.76 | 41 | 4.54 | 1093 | 203 | 0.42 / 1240.87 | 12 | 7 |
3 | 13 | 2054.76 | 20 | 6.92 | 2494 | 345 | 0.76 / 1241.22 | 6 | 7 |
4 | 13 | 2093.20 | 20 | 9.45 | 3015 | 570 | 1.33 / 1241.79 | 6 | 9 |
5 | 13 | 2056.56 | 20 | 10.46 | 2961 | 619 | 1.95 / 1242.41 | 6 | 30 |
6 | 13 | 1981.12 | 20 | 10.94 | 2890 | 632 | 2.59 / 1243.04 | 6 | 40 |
7 | 13 | 1884.64 | 20 | 11.32 | 2801 | 634 | 3.22 / 1243.68 | 6 | 52 |
8 | 13 | 1566.68 | 20 | 12.26 | 2411 | 591 | 3.81 / 1244.27 | 6 | 72 |
9 | 13 | 1025.36 | 20 | 13.00 | 1734 | 451 | 4.26 / 1244.72 | 6 | 84 |
10 | 13 | 366.12 | 20 | 13.73 | 862 | 237 | 4.50 / 1244.95 | 6 | 85 |
11 | 13 | 77.08 | 20 | 14.08 | 472 | 133 | 4.63 / 1245.09 | 6 | 83 |
12 | 13 | 38.96 | 20 | 14.13 | 414 | 117 | 4.75 / 1245.20 | 6 | 75 |
13 | 8 | 0.08 | 242 | 14.09 | 345 | 1176 | 5.93 / 1246.38 | 6 | 131 |
Average= | 27.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.12 | 34 | 14.10 | 462 | 221 | 0.22 / 1237.55 | 7 | 11 |
2 | 7 | 1004.08 | 41 | 4.57 | 1238 | 232 | 0.45 / 1237.78 | 11 | 7 |
3 | 13 | 998.12 | 20 | 12.12 | 1652 | 400 | 0.85 / 1238.18 | 6 | 53 |
4 | 13 | 924.76 | 20 | 12.41 | 1557 | 386 | 1.24 / 1238.57 | 6 | 62 |
5 | 13 | 829.32 | 20 | 12.70 | 1459 | 371 | 1.61 / 1238.94 | 6 | 65 |
6 | 13 | 178.20 | 20 | 13.89 | 609 | 169 | 1.78 / 1239.10 | 6 | 76 |
7 | 13 | 47.16 | 20 | 14.10 | 409 | 115 | 1.90 / 1239.22 | 6 | 74 |
8 | 8 | 0.08 | 261 | 14.08 | 336 | 1235 | 3.13 / 1240.45 | 7 | 132 |
Average= | 27.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.52 | 34 | 14.17 | 448 | 216 | 0.22 / 1234.46 | 7 | 13 |
2 | 7 | 994.64 | 40 | 4.55 | 1152 | 210 | 0.43 / 1234.67 | 13 | 7 |
3 | 13 | 992.24 | 20 | 11.93 | 1635 | 390 | 0.82 / 1235.06 | 6 | 50 |
4 | 13 | 924.08 | 20 | 12.20 | 1559 | 380 | 1.20 / 1235.44 | 6 | 57 |
5 | 13 | 825.68 | 20 | 12.56 | 1455 | 365 | 1.56 / 1235.81 | 6 | 62 |
6 | 13 | 174.44 | 20 | 13.91 | 597 | 166 | 1.73 / 1235.98 | 6 | 77 |
7 | 13 | 52.28 | 20 | 14.09 | 418 | 118 | 1.85 / 1236.09 | 6 | 73 |
8 | 8 | 0.08 | 263 | 14.10 | 332 | 1231 | 3.08 / 1237.32 | 7 | 133 |
Average= | 28.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.48 | 34 | 14.17 | 446 | 215 | 0.21 / 1231.25 | 7 | 9 |
2 | 7 | 1007.36 | 41 | 4.61 | 1371 | 259 | 0.47 / 1231.51 | 9 | 7 |
3 | 13 | 1004.24 | 20 | 12.35 | 1661 | 410 | 0.88 / 1231.92 | 6 | 57 |
4 | 13 | 934.20 | 20 | 12.62 | 1575 | 398 | 1.28 / 1232.32 | 6 | 64 |
5 | 13 | 836.24 | 20 | 12.92 | 1447 | 374 | 1.66 / 1232.69 | 6 | 65 |
6 | 13 | 265.72 | 20 | 13.83 | 714 | 197 | 1.85 / 1232.89 | 6 | 79 |
7 | 13 | 45.56 | 20 | 14.12 | 413 | 117 | 1.97 / 1233.01 | 6 | 73 |
8 | 8 | 0.12 | 261 | 14.10 | 337 | 1240 | 3.21 / 1234.25 | 7 | 140 |
Average= | 28.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.00 | 34 | 14.10 | 462 | 221 | 0.22 / 1225.21 | 7 | 11 |
2 | 7 | 2013.36 | 40 | 4.53 | 1045 | 189 | 0.41 / 1225.40 | 11 | 7 |
3 | 13 | 2066.76 | 20 | 6.57 | 2467 | 324 | 0.74 / 1225.73 | 6 | 7 |
4 | 13 | 2102.24 | 20 | 9.34 | 2992 | 559 | 1.29 / 1226.29 | 6 | 7 |
5 | 13 | 2065.12 | 20 | 10.49 | 2975 | 624 | 1.92 / 1226.91 | 6 | 29 |
6 | 13 | 1990.44 | 20 | 10.94 | 2903 | 635 | 2.55 / 1227.55 | 6 | 39 |
7 | 13 | 1898.04 | 20 | 11.37 | 2804 | 638 | 3.19 / 1228.18 | 6 | 51 |
8 | 13 | 1508.44 | 20 | 12.41 | 2334 | 579 | 3.77 / 1228.76 | 6 | 73 |
9 | 13 | 1410.64 | 20 | 12.54 | 2207 | 554 | 4.32 / 1229.32 | 6 | 77 |
10 | 13 | 613.48 | 20 | 13.44 | 1195 | 321 | 4.64 / 1229.64 | 6 | 84 |
11 | 13 | 86.12 | 20 | 14.06 | 472 | 133 | 4.78 / 1229.77 | 6 | 78 |
12 | 13 | 46.16 | 20 | 14.10 | 403 | 114 | 4.89 / 1229.88 | 6 | 73 |
13 | 8 | 0.08 | 249 | 14.10 | 329 | 1155 | 6.05 / 1231.04 | 7 | 133 |
Average= | 29.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.00 | 34 | 14.10 | 463 | 222 | 0.22 / 1222.08 | 7 | 12 |
2 | 7 | 997.60 | 40 | 4.54 | 1130 | 205 | 0.43 / 1222.28 | 12 | 7 |
3 | 13 | 999.16 | 20 | 11.90 | 1643 | 391 | 0.82 / 1222.67 | 6 | 50 |
4 | 13 | 935.76 | 20 | 12.25 | 1572 | 385 | 1.20 / 1223.06 | 6 | 57 |
5 | 13 | 839.56 | 20 | 12.60 | 1452 | 366 | 1.57 / 1223.42 | 6 | 60 |
6 | 13 | 284.96 | 20 | 13.76 | 729 | 201 | 1.77 / 1223.62 | 6 | 78 |
7 | 13 | 83.48 | 20 | 14.01 | 467 | 131 | 1.90 / 1223.76 | 6 | 74 |
8 | 8 | 0.08 | 266 | 14.09 | 330 | 1237 | 3.14 / 1224.99 | 7 | 130 |
Average= | 29.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.88 | 34 | 14.14 | 462 | 222 | 0.22 / 1218.94 | 7 | 12 |
2 | 7 | 995.08 | 40 | 4.54 | 1126 | 204 | 0.43 / 1219.14 | 12 | 7 |
3 | 13 | 990.96 | 20 | 11.86 | 1632 | 387 | 0.81 / 1219.53 | 6 | 49 |
4 | 13 | 923.56 | 20 | 12.24 | 1553 | 380 | 1.19 / 1219.91 | 6 | 56 |
5 | 13 | 826.64 | 20 | 12.62 | 1436 | 362 | 1.56 / 1220.27 | 6 | 64 |
6 | 13 | 288.56 | 20 | 13.74 | 750 | 206 | 1.76 / 1220.48 | 6 | 72 |
7 | 13 | 89.00 | 20 | 14.01 | 486 | 136 | 1.90 / 1220.62 | 6 | 71 |
8 | 8 | 0.04 | 263 | 14.09 | 334 | 1238 | 3.14 / 1221.85 | 7 | 135 |
Average= | 30.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.64 | 34 | 14.14 | 465 | 224 | 0.22 / 1215.79 | 7 | 10 |
2 | 7 | 1003.76 | 40 | 4.58 | 1283 | 235 | 0.46 / 1216.02 | 10 | 7 |
3 | 13 | 1001.92 | 20 | 12.07 | 1653 | 399 | 0.86 / 1216.42 | 6 | 52 |
4 | 13 | 937.24 | 20 | 12.44 | 1570 | 391 | 1.25 / 1216.81 | 6 | 61 |
5 | 13 | 841.04 | 20 | 12.78 | 1450 | 371 | 1.62 / 1217.18 | 6 | 63 |
6 | 13 | 190.48 | 20 | 13.91 | 604 | 168 | 1.79 / 1217.35 | 6 | 72 |
7 | 13 | 95.44 | 20 | 14.01 | 490 | 137 | 1.92 / 1217.49 | 6 | 72 |
8 | 8 | 0.16 | 263 | 14.09 | 332 | 1230 | 3.15 / 1218.72 | 7 | 129 |
Average= | 31.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.16 | 34 | 14.13 | 449 | 216 | 0.22 / 1209.81 | 7 | 11 |
2 | 7 | 2007.64 | 41 | 4.52 | 1024 | 190 | 0.41 / 1210.00 | 11 | 7 |
3 | 13 | 2058.68 | 20 | 6.13 | 2316 | 284 | 0.69 / 1210.28 | 6 | 7 |
4 | 13 | 2100.96 | 20 | 8.22 | 2924 | 481 | 1.17 / 1210.77 | 6 | 6 |
5 | 13 | 2087.52 | 20 | 10.09 | 3012 | 608 | 1.78 / 1211.37 | 6 | 23 |
6 | 13 | 2032.36 | 20 | 10.78 | 2947 | 635 | 2.41 / 1212.01 | 6 | 37 |
7 | 13 | 1950.00 | 20 | 11.25 | 2875 | 647 | 3.06 / 1212.66 | 6 | 46 |
8 | 13 | 1643.24 | 20 | 12.21 | 2500 | 610 | 3.67 / 1213.27 | 6 | 69 |
9 | 13 | 1115.92 | 20 | 12.88 | 1849 | 476 | 4.15 / 1213.74 | 6 | 85 |
10 | 13 | 594.44 | 20 | 13.46 | 1163 | 313 | 4.46 / 1214.06 | 6 | 84 |
11 | 13 | 147.80 | 20 | 13.97 | 567 | 158 | 4.62 / 1214.21 | 6 | 82 |
12 | 13 | 41.48 | 20 | 14.12 | 401 | 113 | 4.73 / 1214.33 | 6 | 67 |
13 | 8 | 0.16 | 259 | 14.08 | 339 | 1236 | 5.97 / 1215.56 | 6 | 140 |
Average= | 31.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.00 | 34 | 14.14 | 445 | 214 | 0.21 / 1206.73 | 7 | 11 |
2 | 7 | 999.32 | 40 | 4.51 | 1024 | 185 | 0.40 / 1206.92 | 11 | 7 |
3 | 13 | 994.08 | 20 | 10.27 | 1608 | 330 | 0.73 / 1207.25 | 6 | 20 |
4 | 13 | 931.08 | 20 | 11.96 | 1560 | 373 | 1.10 / 1207.62 | 6 | 53 |
5 | 13 | 839.36 | 20 | 12.40 | 1463 | 363 | 1.46 / 1207.99 | 6 | 60 |
6 | 13 | 306.92 | 20 | 13.68 | 785 | 215 | 1.68 / 1208.20 | 6 | 72 |
7 | 13 | 97.80 | 20 | 13.99 | 487 | 136 | 1.82 / 1208.34 | 6 | 69 |
8 | 13 | 26.00 | 20 | 14.11 | 366 | 103 | 1.92 / 1208.44 | 6 | 67 |
9 | 8 | 0.08 | 249 | 14.07 | 330 | 1156 | 3.08 / 1209.60 | 7 | 135 |
Average= | 32.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.84 | 34 | 14.14 | 464 | 223 | 0.22 / 1203.66 | 7 | 9 |
2 | 7 | 994.24 | 40 | 4.51 | 1019 | 184 | 0.41 / 1203.85 | 9 | 7 |
3 | 13 | 995.20 | 20 | 10.80 | 1623 | 351 | 0.76 / 1204.20 | 6 | 28 |
4 | 13 | 935.08 | 20 | 12.02 | 1565 | 376 | 1.13 / 1204.58 | 6 | 54 |
5 | 13 | 740.08 | 20 | 12.96 | 1322 | 343 | 1.48 / 1204.92 | 6 | 63 |
6 | 13 | 319.24 | 20 | 13.69 | 785 | 215 | 1.69 / 1205.13 | 6 | 77 |
7 | 13 | 103.64 | 20 | 13.99 | 499 | 140 | 1.83 / 1205.27 | 6 | 72 |
8 | 13 | 26.12 | 20 | 14.12 | 374 | 106 | 1.94 / 1205.38 | 6 | 68 |
9 | 8 | 0.08 | 251 | 14.09 | 323 | 1142 | 3.08 / 1206.52 | 7 | 141 |
Average= | 33.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.08 | 34 | 14.15 | 446 | 215 | 0.21 / 1200.52 | 7 | 9 |
2 | 7 | 1009.76 | 40 | 4.57 | 1243 | 227 | 0.44 / 1200.75 | 9 | 7 |
3 | 13 | 1006.00 | 20 | 11.94 | 1650 | 394 | 0.84 / 1201.14 | 6 | 49 |
4 | 13 | 932.92 | 20 | 12.45 | 1565 | 390 | 1.23 / 1201.53 | 6 | 59 |
5 | 13 | 835.44 | 20 | 12.80 | 1453 | 372 | 1.60 / 1201.90 | 6 | 64 |
6 | 13 | 277.60 | 20 | 13.79 | 737 | 203 | 1.80 / 1202.10 | 6 | 74 |
7 | 13 | 86.20 | 20 | 14.04 | 463 | 130 | 1.93 / 1202.23 | 6 | 69 |
8 | 13 | 24.40 | 20 | 14.16 | 360 | 102 | 2.03 / 1202.34 | 6 | 69 |
9 | 13 | 11.20 | 20 | 14.11 | 347 | 98 | 2.13 / 1202.43 | 7 | 66 |
10 | 8 | 0.08 | 220 | 14.08 | 325 | 1007 | 3.14 / 1203.44 | 7 | 130 |
Average= | 34.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.48 | 34 | 14.08 | 462 | 221 | 0.22 / 1194.57 | 7 | 10 |
2 | 7 | 2008.56 | 40 | 4.49 | 930 | 167 | 0.39 / 1194.74 | 10 | 7 |
3 | 13 | 2063.72 | 20 | 5.68 | 2133 | 242 | 0.63 / 1194.98 | 6 | 7 |
4 | 13 | 2103.00 | 20 | 7.50 | 2807 | 421 | 1.05 / 1195.40 | 6 | 7 |
5 | 13 | 2106.44 | 20 | 9.79 | 3038 | 595 | 1.65 / 1196.00 | 6 | 17 |
6 | 13 | 2053.96 | 20 | 10.67 | 2977 | 635 | 2.28 / 1196.63 | 6 | 36 |
7 | 13 | 1981.20 | 20 | 11.21 | 2902 | 651 | 2.93 / 1197.28 | 6 | 46 |
8 | 13 | 1893.04 | 20 | 11.58 | 2800 | 648 | 3.58 / 1197.93 | 6 | 57 |
9 | 13 | 1265.80 | 20 | 12.72 | 2035 | 518 | 4.10 / 1198.45 | 6 | 80 |
10 | 13 | 740.76 | 20 | 13.32 | 1332 | 355 | 4.45 / 1198.81 | 6 | 80 |
11 | 13 | 203.08 | 20 | 13.88 | 647 | 180 | 4.63 / 1198.99 | 6 | 78 |
12 | 13 | 63.44 | 20 | 14.10 | 424 | 120 | 4.75 / 1199.10 | 6 | 68 |
13 | 13 | 32.60 | 20 | 14.13 | 377 | 107 | 4.86 / 1199.21 | 6 | 70 |
14 | 8 | 0.04 | 242 | 14.11 | 320 | 1093 | 5.95 / 1200.30 | 7 | 130 |
Average= | 35.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.64 | 34 | 14.12 | 448 | 215 | 0.22 / 1191.44 | 7 | 11 |
2 | 7 | 1005.44 | 40 | 4.52 | 1047 | 189 | 0.40 / 1191.63 | 11 | 7 |
3 | 13 | 1001.56 | 20 | 10.54 | 1622 | 342 | 0.75 / 1191.97 | 6 | 21 |
4 | 13 | 939.64 | 20 | 12.10 | 1566 | 379 | 1.13 / 1192.35 | 6 | 53 |
5 | 13 | 852.00 | 20 | 12.53 | 1461 | 366 | 1.49 / 1192.72 | 6 | 56 |
6 | 13 | 314.00 | 20 | 13.66 | 790 | 216 | 1.71 / 1192.93 | 6 | 76 |
7 | 13 | 101.44 | 20 | 13.95 | 497 | 139 | 1.85 / 1193.07 | 6 | 69 |
8 | 13 | 26.84 | 20 | 14.09 | 374 | 105 | 1.95 / 1193.18 | 6 | 68 |
9 | 8 | 0.16 | 251 | 14.04 | 334 | 1177 | 3.13 / 1194.35 | 7 | 136 |
Average= | 36.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.24 | 34 | 14.15 | 449 | 216 | 0.22 / 1188.37 | 7 | 9 |
2 | 7 | 999.88 | 41 | 4.50 | 988 | 182 | 0.40 / 1188.55 | 9 | 7 |
3 | 13 | 1002.72 | 20 | 9.69 | 1603 | 311 | 0.71 / 1188.86 | 6 | 15 |
4 | 13 | 945.08 | 20 | 12.00 | 1566 | 376 | 1.08 / 1189.24 | 6 | 53 |
5 | 13 | 856.80 | 20 | 12.53 | 1460 | 366 | 1.45 / 1189.61 | 6 | 58 |
6 | 13 | 330.44 | 20 | 13.67 | 789 | 216 | 1.67 / 1189.82 | 6 | 73 |
7 | 13 | 70.84 | 20 | 14.02 | 449 | 126 | 1.79 / 1189.95 | 6 | 70 |
8 | 13 | 21.96 | 20 | 14.11 | 372 | 105 | 1.90 / 1190.05 | 6 | 65 |
9 | 8 | 0.16 | 251 | 14.05 | 332 | 1171 | 3.07 / 1191.22 | 7 | 138 |
Average= | 37.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.20 | 34 | 14.14 | 436 | 210 | 0.21 / 1185.17 | 7 | 8 |
2 | 7 | 1007.40 | 40 | 4.55 | 1157 | 211 | 0.42 / 1185.38 | 8 | 7 |
3 | 13 | 1003.80 | 20 | 11.42 | 1633 | 373 | 0.79 / 1185.75 | 6 | 39 |
4 | 13 | 936.68 | 20 | 12.39 | 1559 | 386 | 1.18 / 1186.14 | 6 | 56 |
5 | 13 | 841.72 | 20 | 12.80 | 1440 | 369 | 1.55 / 1186.51 | 6 | 62 |
6 | 13 | 405.40 | 20 | 13.63 | 887 | 242 | 1.79 / 1186.75 | 6 | 75 |
7 | 13 | 82.24 | 20 | 14.02 | 465 | 130 | 1.92 / 1186.88 | 6 | 75 |
8 | 13 | 41.20 | 20 | 14.08 | 394 | 111 | 2.03 / 1186.99 | 6 | 71 |
9 | 8 | 0.08 | 249 | 14.04 | 334 | 1168 | 3.20 / 1188.16 | 6 | 139 |
Average= | 38.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.08 | 34 | 14.11 | 446 | 214 | 0.21 / 1179.13 | 7 | 11 |
2 | 7 | 2009.80 | 62 | 4.49 | 905 | 252 | 0.47 / 1179.38 | 11 | 7 |
3 | 13 | 2065.88 | 20 | 5.98 | 2353 | 281 | 0.75 / 1179.66 | 6 | 7 |
4 | 13 | 2109.72 | 20 | 8.14 | 2978 | 485 | 1.23 / 1180.15 | 6 | 6 |
5 | 13 | 2093.68 | 20 | 10.43 | 3008 | 627 | 1.86 / 1180.77 | 6 | 28 |
6 | 13 | 2029.96 | 20 | 11.11 | 2962 | 658 | 2.52 / 1181.43 | 6 | 43 |
7 | 13 | 1939.04 | 20 | 11.55 | 2858 | 660 | 3.18 / 1182.09 | 6 | 53 |
8 | 13 | 1641.76 | 20 | 12.28 | 2507 | 616 | 3.79 / 1182.71 | 6 | 71 |
9 | 13 | 1111.76 | 20 | 12.95 | 1792 | 464 | 4.26 / 1183.17 | 6 | 74 |
10 | 13 | 574.84 | 20 | 13.52 | 1119 | 303 | 4.56 / 1183.48 | 6 | 82 |
11 | 13 | 144.04 | 20 | 13.96 | 555 | 155 | 4.72 / 1183.63 | 6 | 78 |
12 | 13 | 36.12 | 20 | 14.12 | 392 | 111 | 4.83 / 1183.74 | 6 | 70 |
13 | 13 | 4.28 | 20 | 14.16 | 344 | 97 | 4.92 / 1183.84 | 6 | 73 |
14 | 8 | 0.04 | 238 | 14.07 | 334 | 1118 | 6.04 / 1184.96 | 7 | 140 |
Average= | 39.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.16 | 34 | 14.08 | 465 | 223 | 0.22 / 1176.07 | 7 | 11 |
2 | 7 | 1001.64 | 40 | 4.51 | 1012 | 183 | 0.41 / 1176.25 | 6 | 7 |
3 | 13 | 997.40 | 20 | 10.40 | 1611 | 335 | 0.74 / 1176.59 | 6 | 19 |
4 | 13 | 935.76 | 20 | 12.20 | 1569 | 383 | 1.12 / 1176.97 | 6 | 54 |
5 | 13 | 744.36 | 20 | 12.99 | 1349 | 350 | 1.47 / 1177.32 | 6 | 65 |
6 | 13 | 245.64 | 20 | 13.75 | 697 | 192 | 1.67 / 1177.51 | 6 | 69 |
7 | 13 | 81.56 | 20 | 13.99 | 463 | 130 | 1.79 / 1177.64 | 6 | 73 |
8 | 13 | 42.48 | 20 | 14.05 | 405 | 114 | 1.91 / 1177.76 | 6 | 72 |
9 | 8 | 0.12 | 249 | 14.04 | 331 | 1157 | 3.07 / 1178.92 | 7 | 134 |
Average= | 40.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.60 | 34 | 14.07 | 465 | 222 | 0.22 / 1172.95 | 7 | 10 |
2 | 7 | 1001.84 | 41 | 4.49 | 970 | 179 | 0.40 / 1173.12 | 10 | 7 |
3 | 13 | 1004.60 | 20 | 9.27 | 1597 | 296 | 0.70 / 1173.42 | 6 | 13 |
4 | 13 | 949.88 | 20 | 12.05 | 1585 | 382 | 1.08 / 1173.80 | 6 | 50 |
5 | 13 | 857.32 | 20 | 12.58 | 1466 | 369 | 1.45 / 1174.17 | 6 | 56 |
6 | 13 | 434.44 | 20 | 13.55 | 927 | 251 | 1.70 / 1174.42 | 6 | 72 |
7 | 13 | 107.44 | 20 | 13.96 | 503 | 140 | 1.84 / 1174.56 | 6 | 73 |
8 | 13 | 55.64 | 20 | 14.02 | 423 | 119 | 1.96 / 1174.68 | 6 | 71 |
9 | 8 | 0.16 | 252 | 14.04 | 330 | 1168 | 3.13 / 1175.85 | 7 | 134 |
Average= | 41.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.28 | 34 | 14.13 | 455 | 219 | 0.22 / 1169.82 | 7 | 10 |
2 | 7 | 1014.16 | 41 | 4.53 | 1085 | 202 | 0.42 / 1170.02 | 10 | 7 |
3 | 13 | 1008.28 | 20 | 10.91 | 1633 | 356 | 0.78 / 1170.38 | 6 | 28 |
4 | 13 | 947.16 | 20 | 12.42 | 1575 | 391 | 1.17 / 1170.77 | 6 | 56 |
5 | 13 | 860.56 | 20 | 12.81 | 1470 | 377 | 1.54 / 1171.15 | 6 | 59 |
6 | 13 | 326.32 | 20 | 13.71 | 798 | 219 | 1.76 / 1171.36 | 6 | 74 |
7 | 13 | 63.72 | 20 | 14.04 | 437 | 123 | 1.89 / 1171.49 | 6 | 71 |
8 | 13 | 17.36 | 20 | 14.11 | 366 | 103 | 1.99 / 1171.59 | 6 | 65 |
9 | 8 | 0.08 | 246 | 14.05 | 328 | 1134 | 3.12 / 1172.72 | 7 | 130 |
Average= | 43.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.60 | 34 | 14.06 | 450 | 215 | 0.22 / 1163.85 | 7 | 13 |
2 | 7 | 2005.32 | 40 | 4.49 | 905 | 163 | 0.38 / 1164.01 | 13 | 7 |
3 | 13 | 2076.96 | 20 | 5.63 | 2120 | 239 | 0.62 / 1164.25 | 6 | 7 |
4 | 13 | 2118.88 | 20 | 7.98 | 2867 | 458 | 1.07 / 1164.71 | 6 | 6 |
5 | 13 | 2108.36 | 20 | 10.44 | 3026 | 632 | 1.71 / 1165.34 | 6 | 28 |
6 | 13 | 2048.08 | 20 | 11.10 | 2981 | 662 | 2.37 / 1166.00 | 6 | 42 |
7 | 13 | 1961.04 | 20 | 11.55 | 2889 | 667 | 3.03 / 1166.67 | 6 | 51 |
8 | 13 | 1771.68 | 20 | 12.06 | 2681 | 647 | 3.68 / 1167.32 | 6 | 63 |
9 | 13 | 1129.00 | 20 | 12.88 | 1862 | 480 | 4.16 / 1167.80 | 6 | 82 |
10 | 13 | 696.12 | 20 | 13.36 | 1286 | 344 | 4.50 / 1168.14 | 6 | 82 |
11 | 13 | 140.08 | 20 | 13.95 | 548 | 153 | 4.66 / 1168.29 | 6 | 77 |
12 | 13 | 41.96 | 20 | 14.09 | 406 | 114 | 4.77 / 1168.41 | 6 | 71 |
13 | 13 | 7.48 | 20 | 14.15 | 353 | 100 | 4.87 / 1168.51 | 6 | 72 |
14 | 8 | 0.04 | 232 | 14.05 | 335 | 1092 | 5.96 / 1169.60 | 7 | 129 |
Average= | 44.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.12 | 34 | 14.04 | 465 | 222 | 0.22 / 1160.83 | 7 | 12 |
2 | 7 | 1005.08 | 40 | 4.49 | 956 | 172 | 0.39 / 1161.00 | 6 | 7 |
3 | 13 | 1007.24 | 20 | 8.92 | 1587 | 283 | 0.68 / 1161.28 | 6 | 8 |
4 | 13 | 942.20 | 20 | 12.12 | 1571 | 381 | 1.06 / 1161.66 | 6 | 52 |
5 | 13 | 855.12 | 20 | 12.63 | 1460 | 369 | 1.43 / 1162.03 | 6 | 62 |
6 | 13 | 346.40 | 20 | 13.65 | 799 | 218 | 1.64 / 1162.25 | 6 | 73 |
7 | 13 | 75.88 | 20 | 13.98 | 459 | 128 | 1.77 / 1162.38 | 6 | 70 |
8 | 13 | 46.00 | 20 | 14.01 | 414 | 116 | 1.89 / 1162.49 | 6 | 68 |
9 | 8 | 0.36 | 246 | 13.99 | 332 | 1143 | 3.03 / 1163.64 | 7 | 131 |
Average= | 46.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.44 | 34 | 14.06 | 450 | 215 | 0.22 / 1157.66 | 7 | 11 |
2 | 7 | 997.08 | 41 | 4.48 | 945 | 174 | 0.39 / 1157.84 | 11 | 7 |
3 | 13 | 996.40 | 20 | 8.88 | 1580 | 281 | 0.67 / 1158.12 | 6 | 10 |
4 | 13 | 947.44 | 20 | 12.13 | 1580 | 383 | 1.05 / 1158.50 | 6 | 51 |
5 | 13 | 861.24 | 20 | 12.65 | 1477 | 374 | 1.43 / 1158.87 | 6 | 58 |
6 | 13 | 653.56 | 20 | 13.24 | 1229 | 325 | 1.75 / 1159.20 | 6 | 68 |
7 | 13 | 94.52 | 20 | 13.96 | 488 | 136 | 1.89 / 1159.34 | 6 | 72 |
8 | 13 | 48.96 | 20 | 14.03 | 415 | 116 | 2.00 / 1159.45 | 6 | 71 |
9 | 8 | 0.12 | 251 | 14.04 | 327 | 1152 | 3.16 / 1160.61 | 7 | 132 |
Average= | 48.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.36 | 34 | 14.07 | 455 | 218 | 0.22 / 1154.47 | 7 | 10 |
2 | 7 | 1008.28 | 40 | 4.52 | 1059 | 191 | 0.41 / 1154.66 | 10 | 7 |
3 | 13 | 1014.00 | 20 | 10.71 | 1636 | 350 | 0.76 / 1155.01 | 6 | 26 |
4 | 13 | 955.60 | 20 | 12.48 | 1583 | 395 | 1.15 / 1155.41 | 6 | 58 |
5 | 13 | 862.40 | 20 | 12.86 | 1485 | 382 | 1.54 / 1155.79 | 6 | 58 |
6 | 13 | 415.84 | 20 | 13.61 | 911 | 248 | 1.78 / 1156.04 | 6 | 71 |
7 | 13 | 90.88 | 20 | 13.99 | 479 | 134 | 1.92 / 1156.17 | 6 | 70 |
8 | 13 | 21.64 | 20 | 14.10 | 372 | 105 | 2.02 / 1156.27 | 6 | 66 |
9 | 8 | 0.04 | 250 | 14.02 | 335 | 1174 | 3.20 / 1157.45 | 7 | 139 |
Average= | 50.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.64 | 34 | 14.04 | 455 | 217 | 0.22 / 1148.54 | 7 | 12 |
2 | 7 | 2001.48 | 40 | 4.48 | 857 | 154 | 0.37 / 1148.70 | 6 | 7 |
3 | 13 | 2063.04 | 20 | 5.55 | 2101 | 233 | 0.60 / 1148.93 | 6 | 7 |
4 | 13 | 2100.60 | 20 | 8.52 | 2945 | 502 | 1.11 / 1149.43 | 6 | 6 |
5 | 13 | 2083.56 | 20 | 10.77 | 3015 | 649 | 1.76 / 1150.08 | 6 | 33 |
6 | 13 | 2023.00 | 20 | 11.34 | 2961 | 672 | 2.43 / 1150.75 | 6 | 43 |
7 | 13 | 1935.48 | 20 | 11.71 | 2842 | 666 | 3.09 / 1151.42 | 6 | 56 |
8 | 13 | 1734.24 | 20 | 12.15 | 2603 | 633 | 3.72 / 1152.05 | 6 | 66 |
9 | 13 | 1100.04 | 20 | 12.92 | 1815 | 469 | 4.19 / 1152.52 | 6 | 83 |
10 | 13 | 560.08 | 20 | 13.50 | 1111 | 300 | 4.49 / 1152.82 | 6 | 81 |
11 | 13 | 115.40 | 20 | 13.95 | 512 | 143 | 4.64 / 1152.96 | 6 | 76 |
12 | 13 | 33.52 | 20 | 14.10 | 386 | 109 | 4.75 / 1153.07 | 6 | 73 |
13 | 8 | 0.16 | 251 | 14.04 | 335 | 1181 | 5.93 / 1154.25 | 6 | 132 |
Average= | 52.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.52 | 34 | 14.02 | 453 | 216 | 0.22 / 1145.54 | 7 | 12 |
2 | 7 | 1010.16 | 41 | 4.48 | 938 | 172 | 0.39 / 1145.72 | 12 | 7 |
3 | 13 | 1007.68 | 20 | 8.45 | 1590 | 269 | 0.66 / 1145.98 | 6 | 6 |
4 | 13 | 952.16 | 20 | 12.14 | 1585 | 385 | 1.04 / 1146.37 | 6 | 54 |
5 | 13 | 861.88 | 20 | 12.68 | 1467 | 372 | 1.41 / 1146.74 | 6 | 59 |
6 | 13 | 448.68 | 20 | 13.50 | 942 | 254 | 1.67 / 1147.00 | 6 | 73 |
7 | 13 | 73.32 | 20 | 13.99 | 444 | 124 | 1.79 / 1147.12 | 6 | 70 |
8 | 13 | 19.16 | 20 | 14.10 | 357 | 101 | 1.89 / 1147.22 | 6 | 64 |
9 | 8 | 0.00 | 249 | 14.03 | 316 | 1104 | 3.00 / 1148.32 | 7 | 135 |
Average= | 54.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.72 | 34 | 13.99 | 461 | 219 | 0.22 / 1142.41 | 7 | 12 |
2 | 7 | 1011.28 | 40 | 4.49 | 952 | 171 | 0.39 / 1142.58 | 12 | 7 |
3 | 13 | 1014.48 | 20 | 8.77 | 1592 | 279 | 0.67 / 1142.86 | 6 | 9 |
4 | 13 | 957.40 | 20 | 12.26 | 1574 | 386 | 1.06 / 1143.25 | 6 | 53 |
5 | 13 | 868.12 | 20 | 12.71 | 1480 | 376 | 1.43 / 1143.62 | 6 | 61 |
6 | 13 | 544.20 | 20 | 13.38 | 1083 | 290 | 1.72 / 1143.91 | 6 | 71 |
7 | 13 | 94.20 | 20 | 13.95 | 481 | 134 | 1.86 / 1144.05 | 6 | 74 |
8 | 13 | 47.72 | 20 | 14.01 | 412 | 115 | 1.97 / 1144.16 | 6 | 75 |
9 | 8 | 0.00 | 249 | 13.99 | 334 | 1163 | 3.13 / 1145.33 | 6 | 129 |
Average= | 57.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.60 | 34 | 14.07 | 437 | 209 | 0.21 / 1139.25 | 7 | 12 |
2 | 7 | 997.28 | 40 | 4.53 | 1102 | 200 | 0.41 / 1139.45 | 12 | 7 |
3 | 13 | 999.20 | 20 | 11.27 | 1614 | 364 | 0.77 / 1139.81 | 6 | 34 |
4 | 13 | 930.28 | 20 | 12.61 | 1553 | 392 | 1.16 / 1140.20 | 6 | 59 |
5 | 13 | 835.12 | 20 | 12.95 | 1441 | 373 | 1.54 / 1140.57 | 6 | 61 |
6 | 13 | 401.36 | 20 | 13.60 | 887 | 241 | 1.78 / 1140.82 | 6 | 75 |
7 | 13 | 42.72 | 20 | 14.04 | 411 | 115 | 1.89 / 1140.93 | 6 | 71 |
8 | 8 | 0.16 | 269 | 14.00 | 335 | 1262 | 3.16 / 1142.19 | 6 | 145 |
Average= | 60.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.08 | 34 | 14.00 | 443 | 211 | 0.21 / 1133.26 | 7 | 12 |
2 | 7 | 2003.76 | 40 | 4.49 | 884 | 159 | 0.37 / 1133.41 | 12 | 7 |
3 | 13 | 2061.80 | 20 | 5.49 | 2126 | 233 | 0.60 / 1133.65 | 6 | 7 |
4 | 13 | 2105.08 | 20 | 8.37 | 2931 | 491 | 1.09 / 1134.14 | 6 | 6 |
5 | 13 | 2094.88 | 20 | 10.95 | 3012 | 660 | 1.75 / 1134.80 | 6 | 34 |
6 | 13 | 2037.00 | 20 | 11.52 | 2945 | 679 | 2.43 / 1135.48 | 6 | 44 |
7 | 13 | 1950.20 | 20 | 11.79 | 2865 | 676 | 3.11 / 1136.15 | 6 | 53 |
8 | 13 | 1751.16 | 20 | 12.21 | 2624 | 641 | 3.75 / 1136.79 | 6 | 65 |
9 | 13 | 1207.72 | 20 | 12.84 | 1947 | 500 | 4.25 / 1137.29 | 6 | 80 |
10 | 13 | 540.40 | 20 | 13.51 | 1086 | 293 | 4.54 / 1137.59 | 6 | 82 |
11 | 13 | 101.04 | 20 | 13.96 | 497 | 139 | 4.68 / 1137.73 | 6 | 80 |
12 | 13 | 24.80 | 20 | 14.08 | 380 | 107 | 4.79 / 1137.83 | 6 | 77 |
13 | 8 | 0.04 | 256 | 14.01 | 336 | 1205 | 5.99 / 1139.04 | 6 | 136 |
Average= | 63.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.72 | 34 | 14.02 | 444 | 212 | 0.21 / 1130.20 | 7 | 11 |
2 | 7 | 1001.56 | 40 | 4.50 | 975 | 175 | 0.39 / 1130.38 | 11 | 7 |
3 | 13 | 1012.36 | 20 | 9.29 | 1602 | 298 | 0.68 / 1130.68 | 6 | 12 |
4 | 13 | 956.40 | 20 | 12.30 | 1578 | 388 | 1.07 / 1131.07 | 6 | 56 |
5 | 13 | 862.12 | 20 | 12.72 | 1466 | 373 | 1.45 / 1131.44 | 6 | 60 |
6 | 13 | 445.08 | 20 | 13.50 | 924 | 249 | 1.70 / 1131.69 | 6 | 70 |
7 | 13 | 56.68 | 20 | 13.97 | 420 | 117 | 1.81 / 1131.81 | 6 | 72 |
8 | 13 | 15.68 | 20 | 14.05 | 362 | 102 | 1.91 / 1131.91 | 6 | 71 |
9 | 8 | 0.00 | 249 | 13.93 | 328 | 1138 | 3.05 / 1133.04 | 6 | 135 |
Average= | 66.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.76 | 34 | 14.06 | 443 | 212 | 0.21 / 1127.21 | 7 | 12 |
2 | 7 | 1005.16 | 41 | 4.50 | 981 | 181 | 0.39 / 1127.40 | 12 | 7 |
3 | 13 | 1001.32 | 20 | 9.46 | 1590 | 301 | 0.69 / 1127.70 | 6 | 15 |
4 | 13 | 945.40 | 20 | 12.34 | 1566 | 386 | 1.08 / 1128.08 | 6 | 57 |
5 | 13 | 853.60 | 20 | 12.77 | 1452 | 371 | 1.45 / 1128.45 | 6 | 63 |
6 | 13 | 221.84 | 20 | 13.77 | 642 | 177 | 1.63 / 1128.63 | 6 | 75 |
7 | 13 | 37.08 | 20 | 14.02 | 394 | 110 | 1.74 / 1128.74 | 6 | 68 |
8 | 13 | 5.60 | 20 | 14.06 | 350 | 98 | 1.84 / 1128.84 | 6 | 67 |
9 | 8 | 0.12 | 249 | 13.95 | 332 | 1153 | 2.99 / 1129.99 | 7 | 133 |
Average= | 70.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.36 | 34 | 14.02 | 448 | 214 | 0.21 / 1124.20 | 7 | 11 |
2 | 7 | 1013.12 | 40 | 4.49 | 965 | 173 | 0.39 / 1124.37 | 11 | 7 |
3 | 13 | 1013.08 | 20 | 9.15 | 1600 | 293 | 0.68 / 1124.66 | 6 | 12 |
4 | 13 | 958.16 | 20 | 12.27 | 1603 | 393 | 1.07 / 1125.06 | 6 | 56 |
5 | 13 | 764.52 | 20 | 13.00 | 1369 | 356 | 1.43 / 1125.41 | 6 | 67 |
6 | 13 | 352.04 | 20 | 13.61 | 822 | 224 | 1.65 / 1125.64 | 6 | 76 |
7 | 13 | 64.04 | 20 | 13.98 | 433 | 121 | 1.77 / 1125.76 | 6 | 71 |
8 | 8 | 0.16 | 270 | 13.96 | 330 | 1244 | 3.02 / 1127.00 | 6 | 134 |
Average= | 75.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.52 | 34 | 13.98 | 436 | 207 | 0.21 / 1121.05 | 7 | 12 |
2 | 7 | 1007.48 | 41 | 4.54 | 1117 | 208 | 0.42 / 1121.25 | 12 | 7 |
3 | 13 | 1036.80 | 20 | 10.92 | 1665 | 364 | 0.78 / 1121.62 | 6 | 30 |
4 | 13 | 973.88 | 20 | 12.46 | 1605 | 400 | 1.18 / 1122.02 | 6 | 58 |
5 | 13 | 875.20 | 20 | 12.85 | 1496 | 384 | 1.56 / 1122.40 | 6 | 64 |
6 | 13 | 349.32 | 20 | 13.62 | 817 | 223 | 1.79 / 1122.62 | 6 | 73 |
7 | 13 | 71.68 | 20 | 13.98 | 441 | 123 | 1.91 / 1122.75 | 6 | 71 |
8 | 8 | 0.48 | 270 | 13.97 | 328 | 1237 | 3.15 / 1123.99 | 7 | 133 |
Average= | 80.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.16 | 34 | 14.01 | 442 | 211 | 0.21 / 1118.08 | 7 | 11 |
2 | 7 | 1005.80 | 41 | 4.49 | 964 | 177 | 0.39 / 1118.26 | 11 | 7 |
3 | 13 | 1004.32 | 20 | 9.62 | 1597 | 307 | 0.70 / 1118.56 | 6 | 16 |
4 | 13 | 941.40 | 20 | 12.43 | 1568 | 390 | 1.09 / 1118.95 | 6 | 58 |
5 | 13 | 858.68 | 20 | 12.82 | 1465 | 376 | 1.46 / 1119.33 | 6 | 63 |
6 | 13 | 327.76 | 20 | 13.63 | 784 | 214 | 1.67 / 1119.54 | 6 | 73 |
7 | 13 | 56.28 | 20 | 14.03 | 406 | 114 | 1.79 / 1119.66 | 6 | 69 |
8 | 8 | 0.12 | 268 | 14.00 | 315 | 1182 | 2.97 / 1120.84 | 6 | 130 |
Average= | 86.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.76 | 34 | 14.00 | 447 | 213 | 0.21 / 1115.11 | 7 | 11 |
2 | 7 | 1008.52 | 40 | 4.50 | 987 | 178 | 0.39 / 1115.29 | 11 | 7 |
3 | 13 | 1008.88 | 20 | 9.69 | 1605 | 311 | 0.70 / 1115.60 | 6 | 18 |
4 | 13 | 946.72 | 20 | 12.42 | 1579 | 392 | 1.09 / 1115.99 | 6 | 58 |
5 | 13 | 854.40 | 20 | 12.83 | 1458 | 374 | 1.47 / 1116.36 | 6 | 64 |
6 | 13 | 301.56 | 20 | 13.68 | 738 | 202 | 1.67 / 1116.57 | 6 | 73 |
7 | 13 | 52.88 | 20 | 14.02 | 405 | 114 | 1.78 / 1116.68 | 6 | 70 |
8 | 8 | 0.16 | 265 | 13.99 | 321 | 1190 | 2.97 / 1117.87 | 7 | 130 |
Average= | 93.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.68 | 34 | 14.02 | 449 | 214 | 0.21 / 1112.14 | 7 | 10 |
2 | 7 | 1008.92 | 41 | 4.50 | 987 | 182 | 0.40 / 1112.33 | 10 | 7 |
3 | 13 | 1008.68 | 20 | 9.79 | 1619 | 317 | 0.71 / 1112.64 | 6 | 20 |
4 | 13 | 945.60 | 20 | 12.42 | 1574 | 391 | 1.10 / 1113.03 | 6 | 59 |
5 | 13 | 754.44 | 20 | 13.03 | 1348 | 351 | 1.46 / 1113.39 | 6 | 67 |
6 | 13 | 237.28 | 20 | 13.75 | 677 | 186 | 1.64 / 1113.57 | 6 | 73 |
7 | 13 | 69.36 | 20 | 13.97 | 439 | 123 | 1.76 / 1113.70 | 6 | 70 |
8 | 8 | 0.08 | 265 | 13.98 | 324 | 1200 | 2.96 / 1114.90 | 6 | 136 |
Average= | 101.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.24 | 34 | 14.00 | 446 | 212 | 0.21 / 1109.18 | 7 | 11 |
2 | 7 | 1011.16 | 40 | 4.51 | 1022 | 184 | 0.40 / 1109.36 | 11 | 7 |
3 | 13 | 1005.52 | 20 | 10.19 | 1619 | 330 | 0.73 / 1109.69 | 6 | 23 |
4 | 13 | 948.20 | 20 | 12.53 | 1574 | 394 | 1.12 / 1110.09 | 6 | 62 |
5 | 13 | 851.36 | 20 | 12.89 | 1465 | 378 | 1.50 / 1110.46 | 6 | 63 |
6 | 13 | 213.12 | 20 | 13.79 | 624 | 172 | 1.67 / 1110.64 | 6 | 74 |
7 | 13 | 59.12 | 20 | 14.00 | 414 | 116 | 1.79 / 1110.75 | 6 | 70 |
8 | 8 | 0.08 | 265 | 13.99 | 318 | 1179 | 2.97 / 1111.93 | 6 | 137 |
Average= | 111.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.60 | 34 | 13.96 | 440 | 209 | 0.21 / 1106.18 | 7 | 11 |
2 | 7 | 1017.48 | 41 | 4.50 | 996 | 184 | 0.39 / 1106.36 | 6 | 7 |
3 | 13 | 1012.80 | 20 | 10.37 | 1627 | 337 | 0.73 / 1106.70 | 6 | 23 |
4 | 13 | 962.08 | 20 | 12.50 | 1600 | 400 | 1.13 / 1107.10 | 6 | 61 |
5 | 13 | 870.08 | 20 | 12.83 | 1487 | 382 | 1.51 / 1107.48 | 6 | 63 |
6 | 13 | 307.52 | 20 | 13.67 | 747 | 204 | 1.72 / 1107.68 | 6 | 74 |
7 | 13 | 55.04 | 20 | 14.02 | 408 | 114 | 1.83 / 1107.80 | 6 | 69 |
8 | 8 | 0.20 | 265 | 14.01 | 314 | 1166 | 3.00 / 1108.97 | 7 | 134 |
Average= | 123.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.00 | 34 | 14.00 | 436 | 208 | 0.21 / 1103.23 | 7 | 11 |
2 | 7 | 1011.32 | 41 | 4.49 | 970 | 179 | 0.39 / 1103.41 | 11 | 7 |
3 | 13 | 1006.88 | 20 | 9.61 | 1608 | 309 | 0.70 / 1103.72 | 6 | 18 |
4 | 13 | 942.32 | 20 | 12.46 | 1570 | 391 | 1.09 / 1104.11 | 6 | 60 |
5 | 13 | 849.08 | 20 | 12.84 | 1471 | 378 | 1.46 / 1104.49 | 6 | 63 |
6 | 13 | 214.36 | 20 | 13.77 | 635 | 175 | 1.64 / 1104.67 | 6 | 71 |
7 | 13 | 67.68 | 20 | 13.99 | 430 | 120 | 1.76 / 1104.79 | 6 | 68 |
8 | 8 | 0.12 | 268 | 14.01 | 315 | 1183 | 2.94 / 1105.97 | 7 | 130 |
Average= | 138.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.32 | 34 | 14.01 | 456 | 217 | 0.22 / 1100.22 | 7 | 10 |
2 | 7 | 1004.76 | 40 | 4.50 | 980 | 176 | 0.39 / 1100.40 | 6 | 7 |
3 | 13 | 1002.88 | 20 | 9.62 | 1594 | 307 | 0.70 / 1100.70 | 6 | 17 |
4 | 13 | 941.96 | 20 | 12.47 | 1565 | 390 | 1.09 / 1101.09 | 6 | 57 |
5 | 13 | 846.32 | 20 | 12.87 | 1445 | 372 | 1.46 / 1101.46 | 6 | 62 |
6 | 13 | 317.00 | 20 | 13.66 | 768 | 210 | 1.67 / 1101.67 | 6 | 74 |
7 | 13 | 107.20 | 20 | 13.91 | 493 | 137 | 1.81 / 1101.81 | 6 | 70 |
8 | 8 | 0.08 | 270 | 14.02 | 321 | 1215 | 3.02 / 1103.03 | 6 | 130 |
Average= | 157.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.96 | 34 | 14.05 | 433 | 207 | 0.21 / 1097.13 | 7 | 10 |
2 | 7 | 1026.28 | 41 | 4.51 | 1024 | 189 | 0.40 / 1097.32 | 6 | 7 |
3 | 13 | 1022.24 | 20 | 10.25 | 1634 | 335 | 0.73 / 1097.66 | 6 | 23 |
4 | 13 | 959.04 | 20 | 12.51 | 1595 | 399 | 1.13 / 1098.06 | 6 | 60 |
5 | 13 | 864.16 | 20 | 12.87 | 1478 | 380 | 1.51 / 1098.44 | 6 | 64 |
6 | 13 | 337.76 | 20 | 13.63 | 807 | 220 | 1.73 / 1098.66 | 6 | 74 |
7 | 13 | 69.32 | 20 | 14.00 | 433 | 121 | 1.85 / 1098.78 | 6 | 66 |
8 | 8 | 0.12 | 270 | 14.01 | 324 | 1226 | 3.08 / 1100.00 | 6 | 132 |
Average= | 183.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.32 | 34 | 14.02 | 443 | 211 | 0.21 / 1094.13 | 7 | 12 |
2 | 7 | 1016.48 | 40 | 4.49 | 956 | 172 | 0.38 / 1094.30 | 12 | 7 |
3 | 13 | 1013.64 | 20 | 9.32 | 1608 | 300 | 0.68 / 1094.60 | 6 | 16 |
4 | 13 | 950.80 | 20 | 12.46 | 1576 | 393 | 1.08 / 1094.99 | 6 | 58 |
5 | 13 | 854.68 | 20 | 12.85 | 1451 | 373 | 1.45 / 1095.37 | 6 | 62 |
6 | 13 | 322.36 | 20 | 13.66 | 758 | 207 | 1.66 / 1095.57 | 6 | 72 |
7 | 13 | 108.20 | 20 | 13.93 | 478 | 133 | 1.79 / 1095.71 | 6 | 72 |
8 | 8 | 0.08 | 273 | 14.02 | 318 | 1217 | 3.01 / 1096.92 | 7 | 137 |
Average= | 219.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.36 | 34 | 14.04 | 430 | 205 | 0.21 / 1091.12 | 7 | 11 |
2 | 7 | 1017.72 | 41 | 4.49 | 972 | 179 | 0.38 / 1091.30 | 11 | 7 |
3 | 13 | 1015.52 | 20 | 9.60 | 1616 | 310 | 0.69 / 1091.61 | 6 | 18 |
4 | 13 | 957.80 | 20 | 12.51 | 1589 | 398 | 1.09 / 1092.00 | 6 | 60 |
5 | 13 | 860.92 | 20 | 12.87 | 1466 | 377 | 1.47 / 1092.38 | 6 | 66 |
6 | 13 | 419.56 | 20 | 13.58 | 887 | 241 | 1.71 / 1092.62 | 6 | 72 |
7 | 13 | 98.00 | 20 | 13.95 | 475 | 133 | 1.84 / 1092.76 | 6 | 70 |
8 | 13 | 7.96 | 20 | 14.13 | 326 | 92 | 1.93 / 1092.85 | 6 | 63 |
9 | 8 | 0.24 | 244 | 14.03 | 313 | 1071 | 3.01 / 1093.92 | 7 | 137 |
Average= | 273.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.52 | 34 | 14.01 | 447 | 213 | 0.21 / 1088.13 | 7 | 10 |
2 | 7 | 1032.20 | 40 | 4.50 | 999 | 180 | 0.39 / 1088.31 | 6 | 7 |
3 | 13 | 1028.04 | 20 | 10.52 | 1644 | 346 | 0.74 / 1088.66 | 6 | 26 |
4 | 13 | 967.40 | 20 | 12.64 | 1587 | 401 | 1.14 / 1089.06 | 6 | 62 |
5 | 13 | 774.04 | 20 | 13.12 | 1356 | 356 | 1.50 / 1089.42 | 6 | 67 |
6 | 13 | 348.80 | 20 | 13.64 | 798 | 218 | 1.71 / 1089.63 | 6 | 74 |
7 | 13 | 70.04 | 20 | 14.01 | 414 | 116 | 1.83 / 1089.75 | 6 | 68 |
8 | 13 | 1.80 | 20 | 14.15 | 320 | 91 | 1.92 / 1089.84 | 6 | 67 |
9 | 8 | 0.00 | 246 | 14.05 | 310 | 1071 | 2.99 / 1090.91 | 7 | 138 |
Average= | 363.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.16 | 34 | 13.98 | 436 | 207 | 0.21 / 1085.14 | 7 | 11 |
2 | 7 | 1014.72 | 41 | 4.52 | 1057 | 196 | 0.40 / 1085.34 | 6 | 7 |
3 | 13 | 1014.48 | 20 | 10.81 | 1636 | 354 | 0.76 / 1085.69 | 6 | 29 |
4 | 13 | 945.80 | 20 | 12.67 | 1569 | 398 | 1.15 / 1086.09 | 6 | 61 |
5 | 13 | 850.36 | 20 | 12.97 | 1451 | 376 | 1.53 / 1086.46 | 6 | 64 |
6 | 13 | 223.12 | 20 | 13.78 | 641 | 177 | 1.71 / 1086.64 | 6 | 73 |
7 | 13 | 73.00 | 20 | 14.00 | 426 | 119 | 1.83 / 1086.76 | 6 | 68 |
8 | 13 | 4.32 | 20 | 14.14 | 323 | 91 | 1.92 / 1086.85 | 6 | 66 |
9 | 8 | 0.08 | 244 | 14.06 | 312 | 1070 | 2.99 / 1087.92 | 7 | 134 |
Average= | 543.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.20 | 34 | 14.00 | 444 | 211 | 0.21 / 1082.11 | 7 | 11 |
2 | 7 | 1016.72 | 41 | 4.50 | 999 | 184 | 0.40 / 1082.29 | 6 | 7 |
3 | 13 | 1019.16 | 20 | 10.43 | 1632 | 340 | 0.74 / 1082.63 | 6 | 23 |
4 | 13 | 954.40 | 20 | 12.63 | 1577 | 398 | 1.13 / 1083.03 | 6 | 59 |
5 | 13 | 857.96 | 20 | 12.94 | 1458 | 377 | 1.51 / 1083.41 | 6 | 62 |
6 | 13 | 322.64 | 20 | 13.66 | 771 | 211 | 1.72 / 1083.62 | 6 | 73 |
7 | 13 | 105.16 | 20 | 13.94 | 479 | 134 | 1.86 / 1083.75 | 6 | 71 |
8 | 13 | 8.68 | 20 | 14.13 | 327 | 92 | 1.95 / 1083.84 | 6 | 67 |
9 | 8 | 0.04 | 249 | 14.04 | 312 | 1091 | 3.04 / 1084.93 | 7 | 135 |
Average= | 1084.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.04 | 34 | 14.09 | 424 | 203 | 0.20 / 1079.12 | 7 | 9 |
2 | 7 | 1006.72 | 40 | 4.56 | 1206 | 220 | 0.42 / 1079.34 | 9 | 7 |
3 | 13 | 1007.28 | 20 | 12.11 | 1634 | 396 | 0.82 / 1079.73 | 6 | 48 |
4 | 13 | 939.60 | 20 | 12.85 | 1553 | 399 | 1.22 / 1080.13 | 6 | 60 |
5 | 13 | 646.88 | 20 | 13.35 | 1197 | 320 | 1.54 / 1080.45 | 6 | 69 |
6 | 13 | 228.00 | 20 | 13.79 | 657 | 181 | 1.72 / 1080.63 | 6 | 72 |
7 | 13 | 67.96 | 20 | 14.02 | 427 | 120 | 1.84 / 1080.75 | 6 | 70 |
8 | 8 | 0.04 | 263 | 14.09 | 308 | 1141 | 2.98 / 1081.89 | 7 | 140 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.56 | 34 | 14.02 | 430 | 205 | 0.20 / 1073.30 | 7 | 10 |
2 | 7 | 2004.28 | 40 | 4.50 | 926 | 167 | 0.37 / 1073.47 | 10 | 7 |
3 | 13 | 2075.20 | 20 | 5.84 | 2321 | 271 | 0.64 / 1073.74 | 6 | 7 |
4 | 13 | 2114.48 | 20 | 10.06 | 3015 | 607 | 1.25 / 1074.35 | 6 | 11 |
5 | 13 | 2074.96 | 20 | 11.39 | 2976 | 678 | 1.93 / 1075.03 | 6 | 43 |
6 | 13 | 2001.44 | 20 | 11.74 | 2904 | 682 | 2.61 / 1075.71 | 6 | 51 |
7 | 13 | 1906.40 | 20 | 11.97 | 2803 | 671 | 3.28 / 1076.38 | 6 | 59 |
8 | 13 | 1487.56 | 20 | 12.53 | 2291 | 574 | 3.85 / 1076.95 | 6 | 76 |
9 | 13 | 1050.12 | 20 | 12.99 | 1734 | 450 | 4.30 / 1077.40 | 6 | 82 |
10 | 13 | 377.12 | 20 | 13.67 | 850 | 232 | 4.54 / 1077.64 | 6 | 81 |
11 | 13 | 82.24 | 20 | 14.00 | 450 | 126 | 4.66 / 1077.76 | 6 | 76 |
12 | 13 | 42.28 | 20 | 14.09 | 381 | 107 | 4.77 / 1077.87 | 6 | 75 |
13 | 8 | 0.12 | 239 | 14.11 | 310 | 1045 | 5.82 / 1078.91 | 7 | 134 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.76 | 34 | 14.04 | 432 | 206 | 0.21 / 1070.29 | 7 | 9 |
2 | 7 | 1012.36 | 41 | 4.50 | 1000 | 184 | 0.39 / 1070.48 | 9 | 7 |
3 | 13 | 1010.52 | 20 | 9.96 | 1608 | 320 | 0.71 / 1070.80 | 6 | 19 |
4 | 13 | 948.68 | 20 | 12.56 | 1568 | 394 | 1.10 / 1071.19 | 6 | 57 |
5 | 13 | 861.92 | 20 | 12.89 | 1461 | 377 | 1.48 / 1071.57 | 6 | 59 |
6 | 13 | 329.96 | 20 | 13.66 | 768 | 210 | 1.69 / 1071.78 | 6 | 72 |
7 | 13 | 66.64 | 20 | 14.01 | 414 | 116 | 1.81 / 1071.90 | 6 | 69 |
8 | 13 | 35.64 | 20 | 14.07 | 370 | 104 | 1.91 / 1072.00 | 6 | 67 |
9 | 8 | 0.08 | 251 | 14.03 | 312 | 1099 | 3.01 / 1073.10 | 7 | 146 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.76 | 34 | 14.02 | 438 | 209 | 0.21 / 1067.26 | 7 | 9 |
2 | 7 | 1005.20 | 41 | 4.52 | 1046 | 194 | 0.40 / 1067.46 | 9 | 7 |
3 | 13 | 996.32 | 20 | 10.77 | 1608 | 346 | 0.75 / 1067.81 | 6 | 28 |
4 | 13 | 937.08 | 20 | 12.62 | 1546 | 390 | 1.14 / 1068.20 | 6 | 57 |
5 | 13 | 840.68 | 20 | 12.96 | 1417 | 367 | 1.51 / 1068.56 | 6 | 60 |
6 | 13 | 397.28 | 20 | 13.59 | 860 | 234 | 1.74 / 1068.80 | 6 | 69 |
7 | 13 | 84.88 | 20 | 13.97 | 439 | 123 | 1.86 / 1068.92 | 6 | 72 |
8 | 13 | 26.72 | 20 | 14.10 | 346 | 98 | 1.96 / 1069.02 | 6 | 68 |
9 | 8 | 0.04 | 249 | 14.06 | 306 | 1071 | 3.03 / 1070.09 | 7 | 136 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.44 | 34 | 14.12 | 423 | 203 | 0.20 / 1064.25 | 7 | 9 |
2 | 7 | 1004.16 | 40 | 4.57 | 1230 | 225 | 0.43 / 1064.48 | 9 | 7 |
3 | 13 | 1003.28 | 20 | 12.23 | 1630 | 399 | 0.83 / 1064.88 | 6 | 49 |
4 | 13 | 937.48 | 20 | 12.84 | 1557 | 400 | 1.23 / 1065.28 | 6 | 61 |
5 | 13 | 739.40 | 20 | 13.27 | 1291 | 343 | 1.57 / 1065.62 | 6 | 68 |
6 | 13 | 208.16 | 20 | 13.84 | 610 | 169 | 1.74 / 1065.79 | 6 | 73 |
7 | 13 | 57.48 | 20 | 14.04 | 402 | 113 | 1.85 / 1065.90 | 6 | 66 |
8 | 13 | 31.20 | 20 | 14.11 | 360 | 102 | 1.95 / 1066.00 | 6 | 67 |
9 | 8 | 0.08 | 247 | 14.11 | 302 | 1053 | 3.00 / 1067.06 | 7 | 133 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.56 | 34 | 14.02 | 433 | 206 | 0.21 / 1058.55 | 7 | 9 |
2 | 7 | 2004.04 | 40 | 4.49 | 898 | 161 | 0.37 / 1058.71 | 9 | 7 |
3 | 13 | 2060.76 | 20 | 5.77 | 2291 | 264 | 0.63 / 1058.97 | 6 | 7 |
4 | 13 | 2095.52 | 20 | 10.16 | 2986 | 607 | 1.24 / 1059.58 | 6 | 13 |
5 | 13 | 2055.44 | 20 | 11.45 | 2964 | 679 | 1.92 / 1060.26 | 6 | 44 |
6 | 13 | 1981.64 | 20 | 11.80 | 2881 | 680 | 2.60 / 1060.94 | 6 | 53 |
7 | 13 | 1888.28 | 20 | 12.01 | 2785 | 669 | 3.27 / 1061.61 | 6 | 60 |
8 | 13 | 1465.52 | 20 | 12.58 | 2259 | 568 | 3.83 / 1062.17 | 6 | 77 |
9 | 13 | 831.64 | 20 | 13.22 | 1437 | 380 | 4.21 / 1062.55 | 6 | 81 |
10 | 13 | 300.76 | 20 | 13.75 | 751 | 207 | 4.42 / 1062.76 | 6 | 78 |
11 | 13 | 94.04 | 20 | 14.00 | 459 | 129 | 4.55 / 1062.89 | 6 | 75 |
12 | 13 | 24.20 | 20 | 14.15 | 350 | 99 | 4.65 / 1062.99 | 6 | 69 |
13 | 8 | 0.12 | 244 | 14.14 | 308 | 1063 | 5.71 / 1064.05 | 7 | 132 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.40 | 34 | 14.05 | 430 | 205 | 0.21 / 1055.50 | 7 | 9 |
2 | 7 | 1008.28 | 41 | 4.51 | 1027 | 190 | 0.40 / 1055.69 | 9 | 7 |
3 | 13 | 1005.24 | 20 | 10.40 | 1604 | 334 | 0.73 / 1056.02 | 6 | 23 |
4 | 13 | 939.08 | 20 | 12.63 | 1553 | 392 | 1.12 / 1056.41 | 6 | 57 |
5 | 13 | 845.04 | 20 | 12.93 | 1446 | 374 | 1.50 / 1056.79 | 6 | 60 |
6 | 13 | 407.00 | 20 | 13.55 | 884 | 240 | 1.73 / 1057.03 | 6 | 72 |
7 | 13 | 95.84 | 20 | 13.95 | 463 | 129 | 1.86 / 1057.15 | 6 | 69 |
8 | 13 | 49.08 | 20 | 14.05 | 389 | 109 | 1.97 / 1057.26 | 6 | 67 |
9 | 8 | 0.20 | 252 | 14.09 | 303 | 1076 | 3.05 / 1058.34 | 7 | 135 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.36 | 34 | 14.06 | 446 | 213 | 0.21 / 1052.46 | 7 | 10 |
2 | 7 | 1011.20 | 41 | 4.52 | 1068 | 198 | 0.41 / 1052.65 | 6 | 7 |
3 | 13 | 1007.96 | 20 | 11.14 | 1619 | 361 | 0.77 / 1053.02 | 6 | 34 |
4 | 13 | 946.32 | 20 | 12.66 | 1567 | 397 | 1.17 / 1053.41 | 6 | 57 |
5 | 13 | 854.60 | 20 | 12.97 | 1454 | 377 | 1.55 / 1053.79 | 6 | 61 |
6 | 13 | 316.24 | 20 | 13.66 | 769 | 210 | 1.76 / 1054.00 | 6 | 71 |
7 | 13 | 103.56 | 20 | 13.96 | 471 | 132 | 1.89 / 1054.13 | 6 | 70 |
8 | 13 | 24.24 | 20 | 14.11 | 345 | 97 | 1.98 / 1054.23 | 6 | 65 |
9 | 8 | 0.12 | 246 | 14.07 | 307 | 1063 | 3.05 / 1055.29 | 7 | 129 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.28 | 34 | 14.14 | 428 | 206 | 0.21 / 1049.45 | 7 | 9 |
2 | 7 | 1008.04 | 40 | 4.59 | 1300 | 239 | 0.44 / 1049.69 | 6 | 7 |
3 | 13 | 1003.20 | 20 | 12.53 | 1622 | 406 | 0.85 / 1050.10 | 6 | 53 |
4 | 13 | 926.52 | 20 | 12.95 | 1542 | 399 | 1.25 / 1050.50 | 6 | 62 |
5 | 13 | 622.68 | 20 | 13.41 | 1161 | 311 | 1.56 / 1050.81 | 6 | 67 |
6 | 13 | 195.32 | 20 | 13.84 | 607 | 168 | 1.73 / 1050.98 | 6 | 72 |
7 | 13 | 59.64 | 20 | 14.04 | 403 | 113 | 1.84 / 1051.09 | 6 | 66 |
8 | 13 | 29.92 | 20 | 14.12 | 360 | 102 | 1.94 / 1051.19 | 6 | 67 |
9 | 8 | 0.12 | 242 | 14.11 | 308 | 1052 | 3.00 / 1052.24 | 7 | 133 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.60 | 34 | 14.00 | 443 | 211 | 0.21 / 1043.73 | 7 | 9 |
2 | 7 | 2001.72 | 41 | 4.53 | 1033 | 192 | 0.40 / 1043.92 | 6 | 7 |
3 | 13 | 2059.16 | 20 | 6.37 | 2591 | 330 | 0.73 / 1044.25 | 6 | 7 |
4 | 13 | 2099.04 | 20 | 11.12 | 3013 | 670 | 1.40 / 1044.92 | 6 | 35 |
5 | 13 | 2054.20 | 20 | 11.72 | 2976 | 698 | 2.10 / 1045.62 | 6 | 48 |
6 | 13 | 1974.52 | 20 | 11.95 | 2866 | 685 | 2.79 / 1046.30 | 6 | 55 |
7 | 13 | 1779.20 | 20 | 12.24 | 2671 | 654 | 3.44 / 1046.96 | 6 | 66 |
8 | 13 | 1450.08 | 20 | 12.65 | 2232 | 565 | 4.00 / 1047.52 | 6 | 77 |
9 | 13 | 681.08 | 20 | 13.38 | 1216 | 325 | 4.33 / 1047.85 | 6 | 76 |
10 | 13 | 158.44 | 20 | 13.90 | 550 | 153 | 4.48 / 1048.00 | 6 | 78 |
11 | 13 | 81.52 | 20 | 14.02 | 442 | 124 | 4.61 / 1048.12 | 6 | 76 |
12 | 8 | 0.12 | 256 | 14.13 | 311 | 1125 | 5.73 / 1049.25 | 7 | 129 |
Average= | 4.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.36 | 34 | 13.99 | 435 | 207 | 0.21 / 1040.70 | 7 | 11 |
2 | 7 | 1012.36 | 40 | 4.51 | 1038 | 187 | 0.39 / 1040.89 | 11 | 7 |
3 | 13 | 1012.12 | 20 | 10.70 | 1617 | 346 | 0.74 / 1041.24 | 6 | 28 |
4 | 13 | 946.76 | 20 | 12.65 | 1554 | 393 | 1.13 / 1041.63 | 6 | 57 |
5 | 13 | 855.88 | 20 | 12.97 | 1442 | 374 | 1.51 / 1042.00 | 6 | 61 |
6 | 13 | 318.92 | 20 | 13.67 | 746 | 204 | 1.71 / 1042.21 | 6 | 70 |
7 | 13 | 69.76 | 20 | 14.00 | 417 | 117 | 1.83 / 1042.32 | 6 | 65 |
8 | 13 | 35.92 | 20 | 14.08 | 359 | 101 | 1.93 / 1042.43 | 6 | 63 |
9 | 8 | 0.08 | 251 | 14.06 | 309 | 1090 | 3.02 / 1043.52 | 7 | 136 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.24 | 34 | 13.99 | 443 | 211 | 0.21 / 1037.70 | 7 | 11 |
2 | 7 | 1004.68 | 40 | 4.53 | 1074 | 195 | 0.41 / 1037.89 | 11 | 7 |
3 | 13 | 1003.20 | 20 | 10.99 | 1615 | 355 | 0.76 / 1038.25 | 6 | 31 |
4 | 13 | 937.88 | 20 | 12.68 | 1545 | 392 | 1.15 / 1038.64 | 6 | 55 |
5 | 13 | 839.16 | 20 | 12.97 | 1422 | 369 | 1.52 / 1039.01 | 6 | 60 |
6 | 13 | 287.24 | 20 | 13.69 | 715 | 196 | 1.72 / 1039.21 | 6 | 71 |
7 | 13 | 57.00 | 20 | 14.02 | 398 | 112 | 1.83 / 1039.32 | 6 | 65 |
8 | 13 | 30.44 | 20 | 14.09 | 359 | 101 | 1.93 / 1039.42 | 6 | 65 |
9 | 8 | 0.12 | 249 | 14.05 | 308 | 1078 | 3.01 / 1040.50 | 7 | 131 |
Average= | 4.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.96 | 34 | 14.02 | 436 | 208 | 0.21 / 1034.71 | 7 | 10 |
2 | 7 | 1007.76 | 40 | 4.53 | 1079 | 196 | 0.40 / 1034.90 | 10 | 7 |
3 | 13 | 1009.12 | 20 | 10.94 | 1615 | 353 | 0.76 / 1035.26 | 6 | 31 |
4 | 13 | 945.96 | 20 | 12.69 | 1549 | 393 | 1.15 / 1035.65 | 6 | 55 |
5 | 13 | 853.52 | 20 | 13.00 | 1443 | 375 | 1.53 / 1036.02 | 6 | 60 |
6 | 13 | 208.72 | 20 | 13.81 | 610 | 168 | 1.69 / 1036.19 | 6 | 69 |
7 | 13 | 64.68 | 20 | 14.00 | 410 | 115 | 1.81 / 1036.31 | 6 | 67 |
8 | 13 | 17.60 | 20 | 14.12 | 340 | 96 | 1.90 / 1036.40 | 6 | 65 |
9 | 8 | 0.20 | 249 | 14.06 | 310 | 1085 | 2.99 / 1037.49 | 7 | 137 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.32 | 34 | 14.01 | 435 | 207 | 0.21 / 1031.56 | 7 | 11 |
2 | 7 | 1012.20 | 40 | 4.56 | 1189 | 217 | 0.42 / 1031.78 | 11 | 7 |
3 | 13 | 1036.60 | 20 | 11.87 | 1671 | 397 | 0.82 / 1032.18 | 6 | 41 |
4 | 13 | 968.52 | 20 | 12.78 | 1590 | 406 | 1.23 / 1032.58 | 6 | 57 |
5 | 13 | 876.32 | 20 | 13.02 | 1487 | 387 | 1.61 / 1032.97 | 6 | 60 |
6 | 13 | 336.04 | 20 | 13.67 | 785 | 215 | 1.83 / 1033.19 | 6 | 68 |
7 | 13 | 113.92 | 20 | 13.93 | 484 | 135 | 1.96 / 1033.32 | 6 | 70 |
8 | 13 | 25.80 | 20 | 14.10 | 352 | 99 | 2.06 / 1033.42 | 6 | 67 |
9 | 8 | 0.04 | 249 | 14.07 | 308 | 1079 | 3.14 / 1034.50 | 7 | 131 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.72 | 34 | 14.00 | 438 | 208 | 0.21 / 1028.56 | 7 | 11 |
2 | 7 | 1009.76 | 41 | 4.54 | 1122 | 209 | 0.42 / 1028.77 | 6 | 7 |
3 | 13 | 1015.28 | 20 | 11.65 | 1633 | 380 | 0.80 / 1029.15 | 6 | 39 |
4 | 13 | 942.64 | 20 | 12.76 | 1543 | 394 | 1.19 / 1029.55 | 6 | 57 |
5 | 13 | 749.04 | 20 | 13.17 | 1315 | 346 | 1.54 / 1029.89 | 6 | 62 |
6 | 13 | 314.24 | 20 | 13.68 | 747 | 204 | 1.74 / 1030.10 | 6 | 69 |
7 | 13 | 54.32 | 20 | 14.03 | 390 | 109 | 1.85 / 1030.21 | 6 | 66 |
8 | 13 | 27.92 | 20 | 14.09 | 350 | 99 | 1.95 / 1030.31 | 6 | 67 |
9 | 8 | 0.16 | 244 | 14.07 | 306 | 1051 | 3.00 / 1031.36 | 6 | 134 |
Average= | 4.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.68 | 34 | 13.95 | 450 | 213 | 0.21 / 1025.60 | 7 | 12 |
2 | 7 | 1009.44 | 40 | 4.54 | 1127 | 205 | 0.42 / 1025.81 | 6 | 7 |
3 | 13 | 1011.40 | 20 | 11.83 | 1632 | 386 | 0.80 / 1026.19 | 6 | 43 |
4 | 13 | 952.12 | 20 | 12.78 | 1567 | 401 | 1.20 / 1026.60 | 6 | 57 |
5 | 13 | 756.00 | 20 | 13.17 | 1327 | 350 | 1.55 / 1026.94 | 6 | 65 |
6 | 13 | 213.96 | 20 | 13.78 | 622 | 171 | 1.73 / 1027.12 | 6 | 71 |
7 | 13 | 53.84 | 20 | 14.00 | 402 | 113 | 1.84 / 1027.23 | 6 | 71 |
8 | 8 | 0.00 | 261 | 14.03 | 308 | 1128 | 2.97 / 1028.36 | 6 | 132 |
Average= | 4.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.04 | 33 | 13.98 | 444 | 205 | 0.20 / 1022.58 | 7 | 12 |
2 | 7 | 1010.16 | 41 | 4.55 | 1173 | 219 | 0.42 / 1022.80 | 6 | 7 |
3 | 13 | 1007.36 | 20 | 12.05 | 1628 | 392 | 0.82 / 1023.19 | 6 | 45 |
4 | 13 | 931.76 | 20 | 12.82 | 1537 | 394 | 1.21 / 1023.59 | 6 | 58 |
5 | 13 | 833.96 | 20 | 13.06 | 1412 | 369 | 1.58 / 1023.95 | 6 | 62 |
6 | 13 | 264.08 | 20 | 13.72 | 697 | 191 | 1.77 / 1024.15 | 6 | 71 |
7 | 13 | 36.52 | 20 | 14.04 | 376 | 106 | 1.88 / 1024.25 | 6 | 71 |
8 | 8 | 0.08 | 258 | 14.01 | 315 | 1139 | 3.01 / 1025.39 | 6 | 134 |
Average= | 4.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.68 | 34 | 13.99 | 435 | 207 | 0.21 / 1019.55 | 7 | 12 |
2 | 7 | 1006.40 | 40 | 4.58 | 1257 | 230 | 0.44 / 1019.78 | 6 | 7 |
3 | 13 | 1006.80 | 20 | 12.31 | 1629 | 401 | 0.84 / 1020.18 | 6 | 49 |
4 | 13 | 931.80 | 20 | 12.87 | 1537 | 396 | 1.23 / 1020.58 | 6 | 58 |
5 | 13 | 840.32 | 20 | 13.05 | 1430 | 373 | 1.61 / 1020.95 | 6 | 63 |
6 | 13 | 200.08 | 20 | 13.80 | 597 | 165 | 1.77 / 1021.12 | 6 | 70 |
7 | 13 | 47.56 | 20 | 14.03 | 394 | 111 | 1.88 / 1021.23 | 6 | 71 |
8 | 8 | 0.04 | 261 | 14.04 | 313 | 1147 | 3.03 / 1022.38 | 6 | 133 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.96 | 34 | 13.99 | 436 | 207 | 0.21 / 1016.56 | 7 | 12 |
2 | 7 | 1008.24 | 41 | 4.54 | 1145 | 213 | 0.42 / 1016.77 | 12 | 7 |
3 | 13 | 1009.96 | 20 | 11.67 | 1630 | 380 | 0.80 / 1017.15 | 6 | 39 |
4 | 13 | 946.76 | 20 | 12.73 | 1551 | 395 | 1.20 / 1017.55 | 6 | 56 |
5 | 13 | 852.40 | 20 | 12.98 | 1455 | 378 | 1.57 / 1017.92 | 6 | 60 |
6 | 13 | 196.12 | 20 | 13.79 | 604 | 167 | 1.74 / 1018.09 | 6 | 70 |
7 | 13 | 51.88 | 20 | 13.99 | 405 | 113 | 1.85 / 1018.20 | 6 | 71 |
8 | 8 | 0.04 | 261 | 14.04 | 312 | 1143 | 3.00 / 1019.35 | 6 | 130 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.20 | 34 | 13.97 | 442 | 210 | 0.21 / 1013.58 | 7 | 11 |
2 | 7 | 1002.72 | 40 | 4.54 | 1137 | 206 | 0.42 / 1013.79 | 11 | 7 |
3 | 13 | 1000.64 | 20 | 11.60 | 1613 | 374 | 0.79 / 1014.16 | 6 | 38 |
4 | 13 | 937.84 | 20 | 12.74 | 1549 | 395 | 1.19 / 1014.55 | 6 | 58 |
5 | 13 | 843.12 | 20 | 13.03 | 1430 | 373 | 1.56 / 1014.93 | 6 | 63 |
6 | 13 | 180.92 | 20 | 13.82 | 577 | 159 | 1.72 / 1015.09 | 6 | 71 |
7 | 13 | 44.32 | 20 | 14.03 | 385 | 108 | 1.83 / 1015.19 | 6 | 70 |
8 | 8 | 0.08 | 261 | 14.01 | 316 | 1155 | 2.98 / 1016.35 | 6 | 131 |
Average= | 4.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.96 | 33 | 14.06 | 427 | 198 | 0.20 / 1010.53 | 7 | 11 |
2 | 7 | 1015.08 | 40 | 4.56 | 1174 | 214 | 0.41 / 1010.74 | 6 | 7 |
3 | 13 | 1008.20 | 20 | 12.03 | 1627 | 391 | 0.80 / 1011.14 | 6 | 47 |
4 | 13 | 936.52 | 20 | 12.80 | 1544 | 395 | 1.20 / 1011.53 | 6 | 59 |
5 | 13 | 837.60 | 20 | 13.03 | 1449 | 378 | 1.58 / 1011.91 | 6 | 64 |
6 | 13 | 278.88 | 20 | 13.71 | 708 | 194 | 1.77 / 1012.10 | 6 | 70 |
7 | 13 | 46.44 | 20 | 14.04 | 388 | 109 | 1.88 / 1012.21 | 6 | 70 |
8 | 8 | 0.08 | 263 | 14.05 | 313 | 1157 | 3.04 / 1013.37 | 6 | 135 |
Average= | 4.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.04 | 33 | 14.03 | 437 | 202 | 0.20 / 1007.43 | 7 | 11 |
2 | 7 | 1010.20 | 40 | 4.59 | 1300 | 239 | 0.44 / 1007.67 | 6 | 7 |
3 | 13 | 1004.20 | 20 | 12.43 | 1633 | 406 | 0.85 / 1008.08 | 6 | 53 |
4 | 13 | 941.32 | 20 | 12.87 | 1556 | 401 | 1.25 / 1008.48 | 6 | 60 |
5 | 13 | 842.52 | 20 | 13.05 | 1446 | 377 | 1.62 / 1008.85 | 6 | 63 |
6 | 13 | 288.36 | 20 | 13.70 | 731 | 200 | 1.83 / 1009.05 | 6 | 72 |
7 | 13 | 42.48 | 20 | 14.05 | 387 | 109 | 1.93 / 1009.16 | 6 | 69 |
8 | 8 | 0.12 | 266 | 14.05 | 313 | 1170 | 3.10 / 1010.33 | 7 | 135 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.04 | 34 | 14.01 | 428 | 204 | 0.20 / 1004.53 | 7 | 11 |
2 | 7 | 1000.84 | 41 | 4.55 | 1158 | 216 | 0.42 / 1004.75 | 11 | 7 |
3 | 13 | 1009.04 | 20 | 11.71 | 1634 | 383 | 0.80 / 1005.13 | 6 | 43 |
4 | 13 | 947.40 | 20 | 12.73 | 1558 | 397 | 1.20 / 1005.53 | 6 | 58 |
5 | 13 | 643.36 | 20 | 13.28 | 1171 | 311 | 1.51 / 1005.84 | 6 | 67 |
6 | 13 | 136.64 | 20 | 13.88 | 513 | 142 | 1.65 / 1005.98 | 6 | 71 |
7 | 13 | 34.96 | 20 | 14.06 | 365 | 103 | 1.76 / 1006.09 | 6 | 68 |
8 | 8 | 0.08 | 261 | 14.03 | 312 | 1142 | 2.90 / 1007.23 | 7 | 133 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.52 | 34 | 14.07 | 427 | 204 | 0.20 / 1001.57 | 7 | 10 |
2 | 7 | 998.16 | 40 | 4.55 | 1153 | 210 | 0.41 / 1001.78 | 10 | 7 |
3 | 13 | 996.84 | 20 | 11.69 | 1610 | 376 | 0.79 / 1002.15 | 6 | 42 |
4 | 13 | 939.20 | 20 | 12.74 | 1548 | 394 | 1.18 / 1002.55 | 6 | 59 |
5 | 13 | 733.72 | 20 | 13.19 | 1288 | 340 | 1.52 / 1002.89 | 6 | 65 |
6 | 13 | 188.36 | 20 | 13.81 | 590 | 163 | 1.69 / 1003.05 | 6 | 71 |
7 | 13 | 54.00 | 20 | 14.02 | 396 | 111 | 1.80 / 1003.16 | 6 | 69 |
8 | 8 | 0.04 | 266 | 14.05 | 313 | 1170 | 2.97 / 1004.33 | 6 | 136 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.40 | 33 | 14.06 | 421 | 195 | 0.20 / 998.52 | 7 | 11 |
2 | 7 | 1017.80 | 40 | 4.56 | 1176 | 215 | 0.41 / 998.74 | 6 | 7 |
3 | 13 | 1013.12 | 20 | 11.70 | 1637 | 383 | 0.79 / 999.12 | 6 | 43 |
4 | 13 | 952.04 | 20 | 12.73 | 1562 | 398 | 1.19 / 999.52 | 6 | 59 |
5 | 13 | 754.56 | 20 | 13.15 | 1337 | 352 | 1.54 / 999.87 | 6 | 65 |
6 | 13 | 325.28 | 20 | 13.63 | 773 | 211 | 1.75 / 1000.08 | 6 | 71 |
7 | 13 | 51.84 | 20 | 14.03 | 400 | 112 | 1.87 / 1000.19 | 6 | 69 |
8 | 8 | 0.16 | 265 | 14.06 | 314 | 1170 | 3.04 / 1001.36 | 7 | 139 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.40 | 33 | 14.04 | 432 | 200 | 0.20 / 995.47 | 7 | 10 |
2 | 7 | 997.88 | 40 | 4.60 | 1338 | 246 | 0.45 / 995.71 | 10 | 7 |
3 | 13 | 1019.56 | 20 | 12.22 | 1649 | 403 | 0.85 / 996.12 | 6 | 49 |
4 | 13 | 966.44 | 20 | 12.78 | 1585 | 405 | 1.25 / 996.52 | 6 | 58 |
5 | 13 | 775.96 | 20 | 13.15 | 1357 | 357 | 1.61 / 996.88 | 6 | 64 |
6 | 13 | 242.00 | 20 | 13.76 | 658 | 181 | 1.79 / 997.06 | 6 | 70 |
7 | 13 | 68.68 | 20 | 14.02 | 412 | 116 | 1.91 / 997.18 | 6 | 71 |
8 | 8 | 0.16 | 265 | 14.07 | 309 | 1152 | 3.06 / 998.33 | 6 | 136 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.96 | 34 | 14.03 | 442 | 211 | 0.21 / 992.45 | 7 | 11 |
2 | 7 | 1002.84 | 41 | 4.55 | 1165 | 217 | 0.43 / 992.67 | 11 | 7 |
3 | 13 | 1008.40 | 20 | 11.59 | 1623 | 376 | 0.80 / 993.04 | 6 | 39 |
4 | 13 | 945.92 | 20 | 12.70 | 1551 | 394 | 1.20 / 993.44 | 6 | 57 |
5 | 13 | 742.32 | 20 | 13.14 | 1322 | 347 | 1.55 / 993.79 | 6 | 64 |
6 | 13 | 319.08 | 20 | 13.65 | 766 | 209 | 1.75 / 994.00 | 6 | 72 |
7 | 13 | 58.76 | 20 | 14.03 | 400 | 112 | 1.87 / 994.11 | 6 | 67 |
8 | 8 | 0.16 | 265 | 14.07 | 311 | 1160 | 3.03 / 995.27 | 7 | 138 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.56 | 34 | 14.07 | 442 | 211 | 0.21 / 989.37 | 7 | 11 |
2 | 7 | 1002.84 | 40 | 4.57 | 1219 | 223 | 0.43 / 989.60 | 11 | 7 |
3 | 13 | 1004.88 | 20 | 11.74 | 1617 | 380 | 0.81 / 989.98 | 6 | 43 |
4 | 13 | 947.32 | 20 | 12.69 | 1562 | 396 | 1.21 / 990.37 | 6 | 58 |
5 | 13 | 850.92 | 20 | 12.96 | 1449 | 376 | 1.59 / 990.75 | 6 | 61 |
6 | 13 | 290.76 | 20 | 13.67 | 726 | 198 | 1.78 / 990.95 | 6 | 71 |
7 | 13 | 83.32 | 20 | 13.98 | 444 | 124 | 1.91 / 991.07 | 6 | 71 |
8 | 8 | 0.08 | 263 | 14.06 | 316 | 1168 | 3.08 / 992.24 | 7 | 135 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.32 | 33 | 14.07 | 450 | 209 | 0.21 / 986.33 | 7 | 10 |
2 | 7 | 1007.44 | 41 | 4.75 | 1405 | 274 | 0.48 / 986.60 | 6 | 6 |
3 | 13 | 982.12 | 20 | 12.62 | 1600 | 404 | 0.89 / 987.00 | 6 | 53 |
4 | 13 | 906.24 | 20 | 13.01 | 1509 | 393 | 1.28 / 987.40 | 6 | 60 |
5 | 13 | 812.76 | 20 | 13.18 | 1406 | 371 | 1.65 / 987.77 | 6 | 63 |
6 | 13 | 145.96 | 20 | 13.90 | 525 | 146 | 1.80 / 987.91 | 6 | 69 |
7 | 13 | 73.04 | 20 | 14.05 | 418 | 117 | 1.91 / 988.03 | 6 | 69 |
8 | 8 | 0.12 | 259 | 14.12 | 310 | 1134 | 3.05 / 989.16 | 7 | 133 |
Average= | 4.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.28 | 33 | 14.07 | 443 | 206 | 0.21 / 980.71 | 7 | 11 |
2 | 7 | 2003.80 | 40 | 4.53 | 1039 | 188 | 0.39 / 980.90 | 11 | 7 |
3 | 13 | 2056.32 | 20 | 6.27 | 2604 | 327 | 0.72 / 981.23 | 6 | 7 |
4 | 13 | 2091.92 | 20 | 10.89 | 2999 | 653 | 1.37 / 981.88 | 6 | 28 |
5 | 13 | 2049.28 | 20 | 11.60 | 2968 | 689 | 2.06 / 982.57 | 6 | 45 |
6 | 13 | 1974.36 | 20 | 11.86 | 2895 | 687 | 2.75 / 983.26 | 6 | 53 |
7 | 13 | 1682.44 | 20 | 12.36 | 2532 | 626 | 3.37 / 983.88 | 6 | 67 |
8 | 13 | 1281.28 | 20 | 12.79 | 2024 | 518 | 3.89 / 984.40 | 6 | 79 |
9 | 13 | 647.44 | 20 | 13.39 | 1204 | 322 | 4.22 / 984.72 | 6 | 80 |
10 | 13 | 127.32 | 20 | 13.97 | 498 | 139 | 4.35 / 984.86 | 6 | 74 |
11 | 13 | 70.80 | 20 | 14.07 | 419 | 118 | 4.47 / 984.98 | 6 | 70 |
12 | 8 | 0.16 | 258 | 14.15 | 311 | 1135 | 5.61 / 986.12 | 7 | 129 |
Average= | 4.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.40 | 33 | 14.05 | 444 | 206 | 0.21 / 977.71 | 7 | 10 |
2 | 7 | 1006.64 | 40 | 4.57 | 1241 | 227 | 0.43 / 977.94 | 6 | 7 |
3 | 13 | 1000.68 | 20 | 12.09 | 1625 | 393 | 0.83 / 978.33 | 6 | 46 |
4 | 13 | 930.96 | 20 | 12.80 | 1540 | 394 | 1.22 / 978.73 | 6 | 57 |
5 | 13 | 729.08 | 20 | 13.19 | 1301 | 343 | 1.56 / 979.07 | 6 | 62 |
6 | 13 | 194.20 | 20 | 13.81 | 593 | 164 | 1.73 / 979.24 | 6 | 70 |
7 | 13 | 100.12 | 20 | 13.98 | 461 | 129 | 1.86 / 979.36 | 6 | 68 |
8 | 8 | 0.16 | 263 | 14.09 | 309 | 1145 | 3.00 / 980.51 | 7 | 134 |
Average= | 4.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.04 | 33 | 14.08 | 432 | 201 | 0.20 / 974.61 | 7 | 10 |
2 | 7 | 1005.60 | 40 | 4.58 | 1264 | 232 | 0.43 / 974.84 | 10 | 7 |
3 | 13 | 1007.32 | 20 | 11.93 | 1627 | 388 | 0.82 / 975.23 | 6 | 44 |
4 | 13 | 939.92 | 20 | 12.76 | 1552 | 396 | 1.22 / 975.62 | 6 | 57 |
5 | 13 | 845.76 | 20 | 13.01 | 1460 | 380 | 1.60 / 976.00 | 6 | 60 |
6 | 13 | 297.88 | 20 | 13.66 | 739 | 202 | 1.80 / 976.20 | 6 | 69 |
7 | 13 | 103.00 | 20 | 13.96 | 468 | 131 | 1.93 / 976.34 | 6 | 67 |
8 | 8 | 0.08 | 268 | 14.12 | 310 | 1173 | 3.10 / 977.51 | 7 | 131 |
Average= | 4.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.36 | 33 | 14.10 | 441 | 205 | 0.21 / 971.53 | 7 | 10 |
2 | 7 | 1017.32 | 40 | 4.68 | 1446 | 271 | 0.48 / 971.80 | 6 | 6 |
3 | 13 | 1002.92 | 20 | 12.69 | 1623 | 412 | 0.89 / 972.21 | 6 | 54 |
4 | 13 | 935.40 | 20 | 13.03 | 1542 | 402 | 1.29 / 972.61 | 6 | 60 |
5 | 13 | 837.80 | 20 | 13.18 | 1439 | 379 | 1.67 / 972.99 | 6 | 61 |
6 | 13 | 183.52 | 20 | 13.85 | 583 | 161 | 1.83 / 973.15 | 6 | 68 |
7 | 13 | 94.28 | 20 | 14.01 | 451 | 126 | 1.96 / 973.28 | 6 | 70 |
8 | 8 | 0.04 | 261 | 14.13 | 306 | 1129 | 3.09 / 974.41 | 7 | 133 |
Average= | 4.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.52 | 33 | 14.03 | 434 | 201 | 0.20 / 965.80 | 7 | 10 |
2 | 7 | 2008.44 | 41 | 4.55 | 1123 | 209 | 0.41 / 966.01 | 10 | 7 |
3 | 13 | 2052.52 | 20 | 6.94 | 2790 | 387 | 0.80 / 966.40 | 6 | 6 |
4 | 13 | 2083.52 | 20 | 11.30 | 3000 | 678 | 1.48 / 967.08 | 6 | 38 |
5 | 13 | 2037.48 | 20 | 11.74 | 2949 | 692 | 2.17 / 967.77 | 6 | 49 |
6 | 13 | 1960.56 | 20 | 12.01 | 2876 | 691 | 2.86 / 968.46 | 6 | 55 |
7 | 13 | 1666.16 | 20 | 12.43 | 2510 | 624 | 3.48 / 969.08 | 6 | 70 |
8 | 13 | 1357.12 | 20 | 12.76 | 2123 | 542 | 4.02 / 969.63 | 6 | 79 |
9 | 13 | 595.32 | 20 | 13.46 | 1137 | 306 | 4.33 / 969.93 | 6 | 80 |
10 | 13 | 156.44 | 20 | 13.93 | 541 | 151 | 4.48 / 970.08 | 6 | 77 |
11 | 13 | 41.04 | 20 | 14.16 | 372 | 105 | 4.59 / 970.19 | 6 | 67 |
12 | 8 | 0.04 | 258 | 14.17 | 310 | 1133 | 5.72 / 971.32 | 7 | 138 |
Average= | 4.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.52 | 33 | 14.06 | 431 | 200 | 0.20 / 962.75 | 7 | 10 |
2 | 7 | 1004.60 | 40 | 4.58 | 1284 | 235 | 0.44 / 962.99 | 10 | 7 |
3 | 13 | 1006.92 | 20 | 12.11 | 1635 | 396 | 0.83 / 963.39 | 6 | 47 |
4 | 13 | 939.08 | 20 | 12.80 | 1542 | 395 | 1.23 / 963.78 | 6 | 58 |
5 | 13 | 743.24 | 20 | 13.19 | 1310 | 346 | 1.57 / 964.13 | 6 | 64 |
6 | 13 | 292.12 | 20 | 13.68 | 727 | 199 | 1.77 / 964.32 | 6 | 71 |
7 | 13 | 98.32 | 20 | 13.98 | 453 | 127 | 1.90 / 964.45 | 6 | 68 |
8 | 13 | 24.40 | 20 | 14.15 | 343 | 97 | 1.99 / 964.55 | 6 | 64 |
9 | 8 | 0.20 | 244 | 14.10 | 306 | 1053 | 3.05 / 965.60 | 7 | 135 |
Average= | 4.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.88 | 33 | 14.07 | 432 | 201 | 0.20 / 959.74 | 7 | 10 |
2 | 7 | 1005.68 | 40 | 4.59 | 1310 | 241 | 0.44 / 959.98 | 10 | 7 |
3 | 13 | 998.00 | 20 | 12.16 | 1616 | 393 | 0.83 / 960.37 | 6 | 46 |
4 | 13 | 932.52 | 20 | 12.78 | 1535 | 392 | 1.23 / 960.76 | 6 | 56 |
5 | 13 | 839.60 | 20 | 13.03 | 1436 | 374 | 1.60 / 961.14 | 6 | 59 |
6 | 13 | 187.56 | 20 | 13.83 | 583 | 161 | 1.76 / 961.30 | 6 | 69 |
7 | 13 | 98.36 | 20 | 13.98 | 455 | 127 | 1.89 / 961.43 | 6 | 66 |
8 | 13 | 7.12 | 20 | 14.20 | 317 | 90 | 1.98 / 961.52 | 7 | 61 |
9 | 8 | 0.04 | 242 | 14.11 | 304 | 1038 | 3.02 / 962.55 | 7 | 135 |
Average= | 4.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.76 | 33 | 14.08 | 434 | 202 | 0.20 / 956.66 | 7 | 9 |
2 | 7 | 1015.88 | 40 | 4.60 | 1343 | 247 | 0.45 / 956.91 | 9 | 7 |
3 | 13 | 1007.40 | 20 | 12.20 | 1634 | 399 | 0.85 / 957.30 | 6 | 48 |
4 | 13 | 938.24 | 20 | 12.80 | 1543 | 395 | 1.24 / 957.70 | 6 | 59 |
5 | 13 | 851.12 | 20 | 13.03 | 1449 | 378 | 1.62 / 958.08 | 6 | 61 |
6 | 13 | 200.40 | 20 | 13.78 | 608 | 168 | 1.79 / 958.24 | 6 | 70 |
7 | 13 | 105.28 | 20 | 13.95 | 470 | 131 | 1.92 / 958.38 | 6 | 69 |
8 | 8 | 0.08 | 268 | 14.11 | 307 | 1161 | 3.08 / 959.54 | 7 | 140 |
Average= | 4.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.04 | 33 | 14.06 | 441 | 205 | 0.20 / 953.52 | 7 | 9 |
2 | 7 | 1008.32 | 40 | 5.01 | 1478 | 296 | 0.50 / 953.82 | 9 | 6 |
3 | 13 | 1022.20 | 20 | 12.54 | 1643 | 412 | 0.91 / 954.23 | 6 | 52 |
4 | 13 | 956.52 | 20 | 12.86 | 1588 | 408 | 1.32 / 954.64 | 6 | 59 |
5 | 13 | 865.48 | 20 | 13.07 | 1480 | 387 | 1.71 / 955.03 | 6 | 61 |
6 | 13 | 219.36 | 20 | 13.78 | 631 | 174 | 1.88 / 955.20 | 6 | 71 |
7 | 13 | 71.68 | 20 | 14.06 | 413 | 116 | 2.00 / 955.32 | 6 | 66 |
8 | 8 | 0.00 | 263 | 14.12 | 307 | 1140 | 3.14 / 956.46 | 7 | 130 |
Average= | 4.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.60 | 33 | 14.10 | 438 | 204 | 0.20 / 950.48 | 7 | 9 |
2 | 7 | 1007.56 | 40 | 4.58 | 1267 | 232 | 0.44 / 950.71 | 9 | 7 |
3 | 13 | 1007.84 | 20 | 12.17 | 1632 | 397 | 0.83 / 951.11 | 6 | 48 |
4 | 13 | 928.92 | 20 | 12.81 | 1530 | 392 | 1.23 / 951.50 | 6 | 59 |
5 | 13 | 831.80 | 20 | 13.05 | 1425 | 372 | 1.60 / 951.87 | 6 | 64 |
6 | 13 | 191.12 | 20 | 13.80 | 591 | 163 | 1.76 / 952.03 | 6 | 71 |
7 | 13 | 58.84 | 20 | 14.06 | 397 | 112 | 1.87 / 952.15 | 6 | 63 |
8 | 8 | -0.04 | 268 | 14.11 | 310 | 1172 | 3.04 / 953.32 | 7 | 140 |
Average= | 4.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.08 | 33 | 14.14 | 440 | 205 | 0.21 / 947.42 | 7 | 9 |
2 | 7 | 1002.80 | 40 | 4.60 | 1338 | 246 | 0.45 / 947.66 | 9 | 7 |
3 | 13 | 1002.84 | 20 | 12.25 | 1634 | 400 | 0.85 / 948.06 | 6 | 49 |
4 | 13 | 930.52 | 20 | 12.81 | 1541 | 395 | 1.25 / 948.46 | 6 | 58 |
5 | 13 | 732.40 | 20 | 13.21 | 1292 | 341 | 1.59 / 948.80 | 6 | 64 |
6 | 13 | 280.08 | 20 | 13.72 | 712 | 195 | 1.78 / 948.99 | 6 | 70 |
7 | 13 | 90.52 | 20 | 13.99 | 446 | 125 | 1.91 / 949.12 | 6 | 67 |
8 | 13 | 21.36 | 20 | 14.15 | 343 | 97 | 2.01 / 949.22 | 6 | 65 |
9 | 8 | 0.08 | 242 | 14.12 | 310 | 1059 | 3.06 / 950.27 | 7 | 137 |
Average= | 4.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.32 | 33 | 14.16 | 438 | 205 | 0.20 / 944.47 | 7 | 9 |
2 | 7 | 1006.44 | 40 | 5.01 | 1437 | 288 | 0.49 / 944.76 | 9 | 6 |
3 | 13 | 968.08 | 20 | 12.76 | 1586 | 405 | 0.90 / 945.17 | 6 | 55 |
4 | 13 | 889.24 | 20 | 13.08 | 1486 | 389 | 1.29 / 945.56 | 6 | 61 |
5 | 13 | 571.24 | 20 | 13.47 | 1084 | 292 | 1.58 / 945.85 | 6 | 68 |
6 | 13 | 144.40 | 20 | 13.93 | 524 | 146 | 1.72 / 945.99 | 6 | 69 |
7 | 13 | 42.32 | 20 | 14.14 | 370 | 105 | 1.83 / 946.10 | 6 | 63 |
8 | 8 | 0.20 | 258 | 14.17 | 304 | 1111 | 2.94 / 947.21 | 7 | 139 |
Average= | 4.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.68 | 33 | 14.11 | 432 | 201 | 0.20 / 938.91 | 7 | 8 |
2 | 7 | 2010.32 | 40 | 4.57 | 1207 | 221 | 0.42 / 939.13 | 6 | 7 |
3 | 13 | 2056.64 | 20 | 7.98 | 2893 | 462 | 0.88 / 939.59 | 6 | 6 |
4 | 13 | 2069.36 | 20 | 11.52 | 2963 | 683 | 1.57 / 940.28 | 6 | 41 |
5 | 13 | 2009.16 | 20 | 11.81 | 2916 | 689 | 2.25 / 940.97 | 6 | 48 |
6 | 13 | 1922.44 | 20 | 12.03 | 2825 | 680 | 2.93 / 941.65 | 6 | 56 |
7 | 13 | 1512.96 | 20 | 12.58 | 2315 | 582 | 3.52 / 942.23 | 6 | 72 |
8 | 13 | 1086.24 | 20 | 13.01 | 1741 | 453 | 3.97 / 942.68 | 6 | 71 |
9 | 13 | 439.96 | 20 | 13.61 | 922 | 251 | 4.22 / 942.93 | 6 | 73 |
10 | 13 | 124.68 | 20 | 13.98 | 498 | 139 | 4.36 / 943.07 | 6 | 73 |
11 | 13 | 34.40 | 20 | 14.17 | 356 | 101 | 4.46 / 943.17 | 6 | 67 |
12 | 13 | 17.60 | 20 | 14.19 | 333 | 95 | 4.56 / 943.27 | 6 | 67 |
13 | 8 | 0.16 | 230 | 14.17 | 308 | 1004 | 5.56 / 944.27 | 7 | 133 |
Average= | 4.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.52 | 33 | 14.10 | 441 | 205 | 0.21 / 935.94 | 7 | 9 |
2 | 7 | 1009.04 | 41 | 4.64 | 1374 | 261 | 0.47 / 936.20 | 9 | 6 |
3 | 13 | 993.72 | 20 | 12.36 | 1615 | 399 | 0.87 / 936.60 | 6 | 50 |
4 | 13 | 935.64 | 20 | 12.83 | 1541 | 395 | 1.26 / 936.99 | 6 | 59 |
5 | 13 | 638.48 | 20 | 13.32 | 1169 | 311 | 1.57 / 937.30 | 6 | 66 |
6 | 13 | 143.24 | 20 | 13.91 | 523 | 145 | 1.72 / 937.45 | 6 | 64 |
7 | 13 | 78.28 | 20 | 14.05 | 421 | 118 | 1.84 / 937.57 | 6 | 64 |
8 | 13 | 5.20 | 20 | 14.19 | 316 | 90 | 1.93 / 937.66 | 6 | 59 |
9 | 8 | 0.04 | 245 | 14.15 | 304 | 1054 | 2.98 / 938.71 | 7 | 134 |
Average= | 4.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.56 | 33 | 14.16 | 447 | 209 | 0.21 / 932.88 | 7 | 9 |
2 | 7 | 1008.44 | 41 | 4.75 | 1410 | 275 | 0.48 / 933.16 | 6 | 6 |
3 | 13 | 994.40 | 20 | 12.52 | 1613 | 404 | 0.89 / 933.56 | 6 | 53 |
4 | 13 | 915.16 | 20 | 12.93 | 1517 | 392 | 1.28 / 933.96 | 6 | 60 |
5 | 13 | 818.36 | 20 | 13.11 | 1412 | 370 | 1.65 / 934.33 | 6 | 64 |
6 | 13 | 159.44 | 20 | 13.88 | 542 | 150 | 1.80 / 934.48 | 6 | 70 |
7 | 13 | 86.92 | 20 | 14.04 | 433 | 122 | 1.92 / 934.60 | 6 | 68 |
8 | 13 | 5.80 | 20 | 14.21 | 315 | 90 | 2.01 / 934.69 | 6 | 62 |
9 | 8 | 0.08 | 239 | 14.13 | 309 | 1044 | 3.05 / 935.73 | 7 | 130 |
Average= | 4.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.44 | 33 | 14.14 | 437 | 204 | 0.20 / 929.96 | 7 | 9 |
2 | 7 | 1005.20 | 41 | 5.51 | 1474 | 333 | 0.54 / 930.29 | 6 | 7 |
3 | 13 | 958.08 | 20 | 12.86 | 1573 | 405 | 0.94 / 930.70 | 6 | 57 |
4 | 13 | 877.68 | 20 | 13.12 | 1481 | 389 | 1.33 / 931.08 | 6 | 63 |
5 | 13 | 481.24 | 20 | 13.55 | 972 | 263 | 1.59 / 931.35 | 6 | 70 |
6 | 13 | 87.04 | 20 | 14.03 | 441 | 124 | 1.72 / 931.47 | 6 | 67 |
7 | 13 | 49.20 | 20 | 14.12 | 384 | 108 | 1.83 / 931.58 | 6 | 65 |
8 | 8 | 0.16 | 251 | 14.17 | 308 | 1095 | 2.92 / 932.68 | 7 | 129 |
Average= | 4.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.80 | 33 | 14.11 | 431 | 201 | 0.20 / 924.28 | 7 | 10 |
2 | 7 | 2003.64 | 40 | 4.60 | 1298 | 239 | 0.44 / 924.52 | 10 | 7 |
3 | 13 | 2053.36 | 20 | 8.69 | 2881 | 501 | 0.94 / 925.02 | 6 | 6 |
4 | 13 | 2067.96 | 20 | 11.57 | 2975 | 688 | 1.63 / 925.71 | 6 | 43 |
5 | 13 | 2012.16 | 20 | 11.84 | 2922 | 692 | 2.32 / 926.40 | 6 | 50 |
6 | 13 | 1924.36 | 20 | 12.08 | 2815 | 680 | 3.00 / 927.08 | 6 | 58 |
7 | 13 | 1727.04 | 20 | 12.41 | 2566 | 637 | 3.64 / 927.72 | 6 | 68 |
8 | 13 | 1171.64 | 20 | 12.96 | 1879 | 487 | 4.12 / 928.20 | 6 | 80 |
9 | 13 | 400.96 | 20 | 13.65 | 864 | 236 | 4.36 / 928.44 | 6 | 77 |
10 | 13 | 97.24 | 20 | 14.04 | 455 | 128 | 4.49 / 928.57 | 6 | 71 |
11 | 13 | 27.24 | 20 | 14.19 | 352 | 100 | 4.59 / 928.67 | 6 | 69 |
12 | 8 | 0.20 | 249 | 14.18 | 308 | 1087 | 5.68 / 929.75 | 6 | 132 |
Average= | 4.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.68 | 33 | 14.13 | 428 | 200 | 0.20 / 921.28 | 7 | 10 |
2 | 7 | 1002.24 | 40 | 4.99 | 1399 | 279 | 0.48 / 921.56 | 6 | 6 |
3 | 13 | 966.32 | 20 | 12.61 | 1579 | 398 | 0.88 / 921.96 | 6 | 54 |
4 | 13 | 896.00 | 20 | 12.96 | 1496 | 388 | 1.26 / 922.34 | 6 | 59 |
5 | 13 | 798.40 | 20 | 13.14 | 1368 | 360 | 1.62 / 922.70 | 6 | 64 |
6 | 13 | 217.20 | 20 | 13.80 | 605 | 167 | 1.79 / 922.87 | 6 | 70 |
7 | 13 | 53.20 | 20 | 14.08 | 386 | 109 | 1.90 / 922.98 | 6 | 67 |
8 | 8 | 0.04 | 256 | 14.12 | 304 | 1099 | 3.00 / 924.08 | 6 | 131 |
Average= | 4.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.92 | 33 | 14.13 | 444 | 207 | 0.21 / 918.34 | 7 | 11 |
2 | 7 | 1005.88 | 40 | 4.95 | 1401 | 277 | 0.48 / 918.61 | 11 | 6 |
3 | 13 | 976.08 | 20 | 12.52 | 1602 | 401 | 0.89 / 919.01 | 6 | 51 |
4 | 13 | 898.92 | 20 | 12.94 | 1497 | 387 | 1.27 / 919.40 | 6 | 59 |
5 | 13 | 596.96 | 20 | 13.38 | 1116 | 299 | 1.57 / 919.70 | 6 | 66 |
6 | 13 | 158.64 | 20 | 13.87 | 548 | 152 | 1.72 / 919.85 | 6 | 70 |
7 | 13 | 47.36 | 20 | 14.12 | 382 | 108 | 1.83 / 919.96 | 6 | 66 |
8 | 8 | 0.16 | 258 | 14.13 | 307 | 1119 | 2.95 / 921.08 | 7 | 131 |
Average= | 4.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.84 | 33 | 14.17 | 441 | 206 | 0.21 / 915.45 | 7 | 10 |
2 | 7 | 1016.16 | 40 | 5.47 | 1475 | 323 | 0.53 / 915.77 | 6 | 7 |
3 | 13 | 963.56 | 20 | 12.87 | 1576 | 406 | 0.93 / 916.18 | 6 | 57 |
4 | 13 | 869.16 | 20 | 13.14 | 1462 | 384 | 1.32 / 916.56 | 6 | 62 |
5 | 13 | 450.48 | 20 | 13.59 | 913 | 248 | 1.57 / 916.81 | 6 | 70 |
6 | 13 | 111.00 | 20 | 14.00 | 474 | 133 | 1.70 / 916.95 | 6 | 70 |
7 | 13 | 26.20 | 20 | 14.17 | 350 | 99 | 1.80 / 917.04 | 6 | 67 |
8 | 8 | 0.12 | 246 | 14.13 | 312 | 1085 | 2.88 / 918.13 | 6 | 129 |
Average= | 4.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.32 | 33 | 14.07 | 438 | 203 | 0.20 / 909.79 | 7 | 12 |
2 | 7 | 2008.44 | 40 | 4.59 | 1268 | 233 | 0.44 / 910.02 | 6 | 7 |
3 | 13 | 2055.32 | 20 | 8.53 | 2900 | 495 | 0.93 / 910.52 | 6 | 6 |
4 | 13 | 2061.64 | 20 | 11.56 | 2952 | 683 | 1.61 / 911.20 | 6 | 39 |
5 | 13 | 2004.68 | 20 | 11.87 | 2890 | 686 | 2.30 / 911.89 | 6 | 47 |
6 | 13 | 1922.92 | 20 | 12.03 | 2832 | 681 | 2.98 / 912.57 | 6 | 55 |
7 | 13 | 1515.68 | 20 | 12.58 | 2322 | 584 | 3.57 / 913.15 | 6 | 72 |
8 | 13 | 1195.52 | 20 | 12.90 | 1922 | 496 | 4.06 / 913.65 | 6 | 78 |
9 | 13 | 419.16 | 20 | 13.61 | 912 | 248 | 4.31 / 913.90 | 6 | 79 |
10 | 13 | 100.92 | 20 | 14.01 | 468 | 131 | 4.44 / 914.03 | 6 | 76 |
11 | 13 | 9.68 | 20 | 14.19 | 334 | 95 | 4.54 / 914.12 | 6 | 70 |
12 | 8 | 0.08 | 249 | 14.14 | 319 | 1123 | 5.66 / 915.25 | 6 | 131 |
Average= | 4.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.76 | 33 | 14.12 | 438 | 204 | 0.20 / 906.86 | 7 | 11 |
2 | 7 | 1016.20 | 40 | 5.08 | 1430 | 291 | 0.49 / 907.15 | 11 | 6 |
3 | 13 | 980.72 | 20 | 12.54 | 1598 | 401 | 0.90 / 907.55 | 6 | 52 |
4 | 13 | 898.64 | 20 | 12.92 | 1494 | 386 | 1.28 / 907.94 | 6 | 59 |
5 | 13 | 593.52 | 20 | 13.37 | 1113 | 298 | 1.58 / 908.24 | 6 | 66 |
6 | 13 | 97.76 | 20 | 14.00 | 453 | 127 | 1.71 / 908.36 | 6 | 68 |
7 | 13 | 50.80 | 20 | 14.08 | 387 | 109 | 1.81 / 908.47 | 6 | 68 |
8 | 8 | 0.04 | 254 | 14.11 | 311 | 1115 | 2.93 / 909.59 | 7 | 132 |
Average= | 4.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.96 | 33 | 14.11 | 442 | 206 | 0.21 / 903.96 | 7 | 12 |
2 | 7 | 1011.80 | 41 | 5.14 | 1418 | 299 | 0.50 / 904.26 | 12 | 6 |
3 | 13 | 981.96 | 20 | 12.55 | 1595 | 400 | 0.90 / 904.66 | 6 | 54 |
4 | 13 | 896.68 | 20 | 12.95 | 1488 | 385 | 1.29 / 905.05 | 6 | 62 |
5 | 13 | 497.80 | 20 | 13.49 | 979 | 264 | 1.55 / 905.31 | 6 | 68 |
6 | 13 | 93.20 | 20 | 13.99 | 452 | 126 | 1.68 / 905.44 | 6 | 68 |
7 | 13 | 23.24 | 20 | 14.15 | 348 | 98 | 1.78 / 905.54 | 6 | 67 |
8 | 8 | 0.04 | 254 | 14.10 | 313 | 1121 | 2.90 / 906.66 | 6 | 129 |
Average= | 4.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.12 | 33 | 14.19 | 445 | 208 | 0.21 / 901.08 | 7 | 11 |
2 | 7 | 1011.48 | 40 | 5.41 | 1458 | 316 | 0.52 / 901.39 | 6 | 7 |
3 | 13 | 961.28 | 20 | 12.87 | 1574 | 405 | 0.93 / 901.80 | 6 | 59 |
4 | 13 | 862.44 | 20 | 13.15 | 1445 | 380 | 1.31 / 902.18 | 6 | 64 |
5 | 13 | 447.60 | 20 | 13.57 | 932 | 253 | 1.56 / 902.43 | 6 | 70 |
6 | 13 | 109.44 | 20 | 13.97 | 480 | 134 | 1.70 / 902.57 | 6 | 72 |
7 | 8 | 0.12 | 268 | 14.12 | 315 | 1192 | 2.89 / 903.76 | 6 | 132 |
Average= | 4.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.88 | 33 | 14.10 | 437 | 203 | 0.20 / 895.38 | 7 | 13 |
2 | 7 | 2004.28 | 40 | 4.61 | 1321 | 244 | 0.45 / 895.63 | 6 | 7 |
3 | 13 | 2058.96 | 20 | 9.36 | 2915 | 546 | 0.99 / 896.17 | 6 | 6 |
4 | 13 | 2047.08 | 20 | 11.62 | 2950 | 686 | 1.68 / 896.86 | 6 | 43 |
5 | 13 | 1978.52 | 20 | 11.88 | 2905 | 690 | 2.37 / 897.55 | 6 | 49 |
6 | 13 | 1782.44 | 20 | 12.27 | 2654 | 651 | 3.02 / 898.20 | 6 | 62 |
7 | 13 | 1583.48 | 20 | 12.51 | 2417 | 605 | 3.62 / 898.80 | 6 | 71 |
8 | 13 | 1132.32 | 20 | 12.94 | 1857 | 481 | 4.11 / 899.28 | 6 | 81 |
9 | 13 | 436.28 | 20 | 13.60 | 941 | 256 | 4.36 / 899.54 | 6 | 79 |
10 | 13 | 54.40 | 20 | 14.10 | 412 | 116 | 4.48 / 899.66 | 6 | 74 |
11 | 8 | 0.12 | 264 | 14.14 | 325 | 1213 | 5.69 / 900.87 | 6 | 137 |
Average= | 4.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.12 | 33 | 14.09 | 432 | 201 | 0.20 / 892.48 | 7 | 12 |
2 | 7 | 1011.08 | 41 | 5.08 | 1416 | 295 | 0.50 / 892.78 | 12 | 6 |
3 | 13 | 983.08 | 20 | 12.54 | 1600 | 401 | 0.90 / 893.18 | 6 | 56 |
4 | 13 | 902.64 | 20 | 12.91 | 1502 | 388 | 1.28 / 893.57 | 6 | 61 |
5 | 13 | 498.84 | 20 | 13.47 | 983 | 265 | 1.55 / 893.83 | 6 | 70 |
6 | 13 | 92.56 | 20 | 13.98 | 445 | 124 | 1.67 / 893.96 | 6 | 73 |
7 | 13 | 47.20 | 20 | 14.07 | 386 | 109 | 1.78 / 894.07 | 6 | 71 |
8 | 8 | 0.04 | 251 | 14.07 | 315 | 1112 | 2.90 / 895.18 | 6 | 131 |
Average= | 4.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.48 | 33 | 14.07 | 437 | 203 | 0.20 / 889.54 | 7 | 12 |
2 | 7 | 1002.76 | 41 | 5.42 | 1408 | 313 | 0.52 / 889.85 | 12 | 7 |
3 | 13 | 967.32 | 20 | 12.61 | 1578 | 398 | 0.91 / 890.25 | 6 | 55 |
4 | 13 | 876.20 | 20 | 12.98 | 1466 | 381 | 1.29 / 890.63 | 6 | 62 |
5 | 13 | 660.24 | 20 | 13.31 | 1210 | 322 | 1.62 / 890.95 | 6 | 67 |
6 | 13 | 101.32 | 20 | 13.96 | 474 | 132 | 1.75 / 891.09 | 6 | 71 |
7 | 8 | 0.16 | 271 | 14.11 | 313 | 1197 | 2.95 / 892.28 | 7 | 134 |
Average= | 4.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.68 | 33 | 14.16 | 434 | 203 | 0.20 / 886.63 | 7 | 10 |
2 | 7 | 1009.28 | 41 | 5.70 | 1472 | 344 | 0.55 / 886.98 | 10 | 8 |
3 | 13 | 958.44 | 20 | 12.91 | 1574 | 406 | 0.95 / 887.38 | 6 | 60 |
4 | 13 | 864.72 | 20 | 13.15 | 1480 | 389 | 1.34 / 887.77 | 6 | 62 |
5 | 13 | 439.68 | 20 | 13.59 | 925 | 251 | 1.59 / 888.02 | 6 | 71 |
6 | 13 | 105.28 | 20 | 14.00 | 477 | 134 | 1.73 / 888.16 | 6 | 71 |
7 | 8 | 0.12 | 265 | 14.14 | 315 | 1180 | 2.91 / 889.34 | 6 | 134 |
Average= | 4.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.36 | 33 | 14.07 | 438 | 203 | 0.20 / 881.03 | 7 | 12 |
2 | 7 | 2008.96 | 41 | 4.60 | 1318 | 249 | 0.45 / 881.28 | 12 | 7 |
3 | 13 | 2055.20 | 20 | 9.47 | 2925 | 554 | 1.01 / 881.83 | 6 | 7 |
4 | 13 | 2035.20 | 20 | 11.66 | 2936 | 685 | 1.69 / 882.51 | 6 | 46 |
5 | 13 | 1971.84 | 20 | 11.93 | 2873 | 685 | 2.38 / 883.20 | 6 | 52 |
6 | 13 | 1885.80 | 20 | 12.18 | 2754 | 671 | 3.05 / 883.87 | 6 | 59 |
7 | 13 | 1574.80 | 20 | 12.51 | 2394 | 599 | 3.65 / 884.47 | 6 | 73 |
8 | 13 | 1021.20 | 20 | 13.07 | 1688 | 441 | 4.09 / 884.91 | 6 | 81 |
9 | 13 | 361.80 | 20 | 13.69 | 832 | 228 | 4.32 / 885.14 | 6 | 79 |
10 | 13 | 69.56 | 20 | 14.10 | 421 | 119 | 4.43 / 885.26 | 6 | 76 |
11 | 13 | 15.72 | 20 | 14.19 | 345 | 98 | 4.53 / 885.36 | 6 | 74 |
12 | 8 | -0.04 | 242 | 14.15 | 314 | 1075 | 5.61 / 886.43 | 6 | 130 |
Average= | 4.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.20 | 33 | 14.09 | 456 | 212 | 0.21 / 878.11 | 7 | 12 |
2 | 7 | 1007.28 | 40 | 5.66 | 1439 | 326 | 0.54 / 878.44 | 6 | 8 |
3 | 13 | 971.28 | 20 | 12.70 | 1589 | 404 | 0.94 / 878.84 | 6 | 57 |
4 | 13 | 887.16 | 20 | 12.99 | 1486 | 386 | 1.33 / 879.23 | 6 | 64 |
5 | 13 | 468.08 | 20 | 13.51 | 941 | 254 | 1.58 / 879.48 | 6 | 71 |
6 | 13 | 134.72 | 20 | 13.94 | 493 | 137 | 1.72 / 879.62 | 6 | 73 |
7 | 13 | 28.56 | 20 | 14.12 | 354 | 100 | 1.82 / 879.72 | 6 | 71 |
8 | 8 | 0.00 | 251 | 14.10 | 312 | 1104 | 2.92 / 880.82 | 7 | 129 |
Average= | 4.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.40 | 33 | 14.14 | 440 | 205 | 0.21 / 875.17 | 7 | 11 |
2 | 7 | 1007.80 | 40 | 5.61 | 1438 | 323 | 0.53 / 875.49 | 6 | 9 |
3 | 13 | 970.92 | 20 | 12.63 | 1597 | 403 | 0.93 / 875.90 | 6 | 57 |
4 | 13 | 887.96 | 20 | 12.99 | 1479 | 384 | 1.32 / 876.28 | 6 | 62 |
5 | 13 | 473.88 | 20 | 13.50 | 972 | 262 | 1.58 / 876.54 | 6 | 70 |
6 | 13 | 87.44 | 20 | 14.01 | 450 | 126 | 1.70 / 876.67 | 6 | 69 |
7 | 13 | 24.32 | 20 | 14.16 | 360 | 102 | 1.81 / 876.77 | 6 | 67 |
8 | 8 | 0.08 | 251 | 14.11 | 319 | 1130 | 2.94 / 877.90 | 6 | 136 |
Average= | 4.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.20 | 33 | 14.24 | 433 | 203 | 0.20 / 872.30 | 7 | 9 |
2 | 7 | 1003.96 | 40 | 6.25 | 1507 | 377 | 0.58 / 872.68 | 9 | 11 |
3 | 13 | 945.20 | 20 | 12.94 | 1565 | 405 | 0.99 / 873.08 | 6 | 61 |
4 | 13 | 865.48 | 20 | 13.17 | 1455 | 383 | 1.37 / 873.47 | 6 | 65 |
5 | 13 | 407.76 | 20 | 13.64 | 864 | 236 | 1.60 / 873.70 | 6 | 72 |
6 | 13 | 54.52 | 20 | 14.10 | 391 | 110 | 1.71 / 873.81 | 6 | 67 |
7 | 8 | 0.08 | 265 | 14.17 | 307 | 1153 | 2.87 / 874.96 | 7 | 132 |
Average= | 4.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.60 | 33 | 14.13 | 447 | 208 | 0.21 / 866.90 | 7 | 11 |
2 | 7 | 2006.08 | 40 | 4.64 | 1463 | 272 | 0.48 / 867.17 | 6 | 7 |
3 | 13 | 2054.76 | 20 | 10.69 | 2944 | 629 | 1.11 / 867.80 | 6 | 24 |
4 | 13 | 2025.48 | 20 | 11.74 | 2923 | 686 | 1.80 / 868.48 | 6 | 47 |
5 | 13 | 1953.44 | 20 | 12.03 | 2822 | 679 | 2.47 / 869.16 | 6 | 53 |
6 | 13 | 1760.80 | 20 | 12.37 | 2618 | 648 | 3.12 / 869.81 | 6 | 64 |
7 | 13 | 1562.48 | 20 | 12.57 | 2374 | 597 | 3.72 / 870.41 | 6 | 71 |
8 | 13 | 592.96 | 20 | 13.47 | 1130 | 304 | 4.02 / 870.71 | 6 | 78 |
9 | 13 | 174.08 | 20 | 13.93 | 570 | 159 | 4.18 / 870.87 | 6 | 74 |
10 | 13 | 47.44 | 20 | 14.16 | 382 | 108 | 4.29 / 870.98 | 6 | 69 |
11 | 8 | 0.12 | 258 | 14.21 | 305 | 1118 | 5.41 / 872.10 | 7 | 134 |
Average= | 4.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.32 | 33 | 14.13 | 447 | 208 | 0.21 / 863.92 | 7 | 11 |
2 | 7 | 1011.24 | 40 | 5.44 | 1412 | 307 | 0.52 / 864.22 | 11 | 7 |
3 | 13 | 973.56 | 20 | 12.66 | 1586 | 402 | 0.92 / 864.63 | 6 | 57 |
4 | 13 | 876.52 | 20 | 12.97 | 1474 | 382 | 1.30 / 865.01 | 6 | 63 |
5 | 13 | 677.80 | 20 | 13.30 | 1213 | 323 | 1.62 / 865.33 | 6 | 68 |
6 | 13 | 107.36 | 20 | 13.99 | 476 | 133 | 1.76 / 865.46 | 6 | 72 |
7 | 13 | 55.96 | 20 | 14.09 | 398 | 112 | 1.87 / 865.58 | 6 | 71 |
8 | 8 | 0.12 | 254 | 14.13 | 310 | 1113 | 2.98 / 866.69 | 6 | 135 |
Average= | 4.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.72 | 33 | 14.19 | 435 | 204 | 0.20 / 860.97 | 7 | 10 |
2 | 7 | 1005.64 | 40 | 5.80 | 1433 | 332 | 0.54 / 861.31 | 10 | 9 |
3 | 13 | 960.72 | 20 | 12.70 | 1570 | 399 | 0.93 / 861.71 | 6 | 57 |
4 | 13 | 864.88 | 20 | 13.00 | 1461 | 380 | 1.31 / 862.09 | 6 | 62 |
5 | 13 | 557.32 | 20 | 13.44 | 1079 | 290 | 1.60 / 862.38 | 6 | 69 |
6 | 13 | 119.48 | 20 | 13.96 | 502 | 140 | 1.74 / 862.52 | 6 | 69 |
7 | 13 | 13.84 | 20 | 14.21 | 330 | 94 | 1.84 / 862.61 | 6 | 63 |
8 | 8 | 0.04 | 249 | 14.14 | 312 | 1099 | 2.94 / 863.71 | 7 | 131 |
Average= | 4.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.92 | 33 | 14.20 | 449 | 210 | 0.21 / 858.09 | 7 | 11 |
2 | 7 | 1015.12 | 40 | 6.28 | 1507 | 379 | 0.59 / 858.47 | 6 | 11 |
3 | 13 | 949.48 | 20 | 13.01 | 1569 | 408 | 1.00 / 858.88 | 6 | 62 |
4 | 13 | 861.12 | 20 | 13.19 | 1478 | 390 | 1.39 / 859.27 | 6 | 62 |
5 | 13 | 321.08 | 20 | 13.73 | 773 | 212 | 1.60 / 859.48 | 6 | 72 |
6 | 13 | 67.72 | 20 | 14.14 | 409 | 116 | 1.72 / 859.60 | 6 | 65 |
7 | 8 | 0.12 | 265 | 14.18 | 312 | 1172 | 2.89 / 860.77 | 7 | 132 |
Average= | 4.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.64 | 33 | 14.14 | 440 | 205 | 0.21 / 852.64 | 7 | 11 |
2 | 7 | 2001.08 | 41 | 4.61 | 1331 | 252 | 0.46 / 852.89 | 11 | 7 |
3 | 13 | 2056.20 | 20 | 9.83 | 2939 | 578 | 1.03 / 853.47 | 6 | 10 |
4 | 13 | 2042.16 | 20 | 11.70 | 2953 | 691 | 1.73 / 854.16 | 6 | 46 |
5 | 13 | 1986.16 | 20 | 11.93 | 2887 | 689 | 2.41 / 854.85 | 6 | 51 |
6 | 13 | 1906.20 | 20 | 12.14 | 2783 | 676 | 3.09 / 855.52 | 6 | 60 |
7 | 13 | 1380.84 | 20 | 12.73 | 2150 | 547 | 3.64 / 856.07 | 6 | 78 |
8 | 13 | 732.32 | 20 | 13.32 | 1324 | 353 | 3.99 / 856.42 | 6 | 81 |
9 | 13 | 285.72 | 20 | 13.80 | 719 | 198 | 4.19 / 856.62 | 6 | 79 |
10 | 13 | 91.96 | 20 | 14.12 | 441 | 125 | 4.31 / 856.75 | 6 | 73 |
11 | 8 | 0.08 | 261 | 14.22 | 306 | 1136 | 5.45 / 857.88 | 7 | 137 |
Average= | 4.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.72 | 33 | 14.15 | 439 | 205 | 0.20 / 849.63 | 7 | 12 |
2 | 7 | 1013.40 | 40 | 5.63 | 1463 | 329 | 0.53 / 849.96 | 6 | 9 |
3 | 13 | 984.24 | 20 | 12.74 | 1608 | 410 | 0.94 / 850.37 | 6 | 58 |
4 | 13 | 898.64 | 20 | 13.02 | 1500 | 391 | 1.33 / 850.76 | 6 | 64 |
5 | 13 | 689.92 | 20 | 13.31 | 1243 | 331 | 1.67 / 851.09 | 6 | 68 |
6 | 13 | 141.64 | 20 | 13.96 | 509 | 142 | 1.81 / 851.24 | 6 | 67 |
7 | 13 | 73.64 | 20 | 14.13 | 408 | 115 | 1.92 / 851.35 | 6 | 65 |
8 | 8 | 0.12 | 251 | 14.19 | 304 | 1083 | 3.01 / 852.43 | 7 | 129 |
Average= | 4.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.00 | 33 | 14.19 | 442 | 207 | 0.21 / 846.73 | 7 | 12 |
2 | 7 | 1008.12 | 40 | 5.78 | 1432 | 331 | 0.54 / 847.06 | 12 | 9 |
3 | 13 | 967.04 | 20 | 12.71 | 1584 | 403 | 0.94 / 847.47 | 6 | 57 |
4 | 13 | 890.16 | 20 | 13.00 | 1491 | 388 | 1.33 / 847.85 | 6 | 63 |
5 | 13 | 468.00 | 20 | 13.54 | 939 | 254 | 1.58 / 848.11 | 6 | 71 |
6 | 13 | 145.08 | 20 | 13.98 | 502 | 140 | 1.72 / 848.25 | 6 | 69 |
7 | 13 | 35.52 | 20 | 14.20 | 354 | 101 | 1.82 / 848.35 | 6 | 62 |
8 | 8 | 0.08 | 251 | 14.19 | 303 | 1079 | 2.90 / 849.43 | 7 | 140 |
Average= | 4.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.48 | 33 | 14.28 | 425 | 200 | 0.20 / 843.85 | 7 | 11 |
2 | 7 | 1007.12 | 40 | 5.91 | 1483 | 351 | 0.55 / 844.20 | 11 | 9 |
3 | 13 | 951.20 | 20 | 12.99 | 1574 | 409 | 0.96 / 844.61 | 6 | 61 |
4 | 13 | 861.44 | 20 | 13.19 | 1456 | 384 | 1.34 / 845.00 | 6 | 65 |
5 | 13 | 527.32 | 20 | 13.54 | 1016 | 275 | 1.62 / 845.27 | 6 | 73 |
6 | 13 | 109.52 | 20 | 14.10 | 447 | 126 | 1.75 / 845.40 | 6 | 68 |
7 | 8 | 0.12 | 265 | 14.23 | 299 | 1128 | 2.87 / 846.53 | 7 | 135 |
Average= | 4.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.76 | 33 | 14.11 | 456 | 212 | 0.21 / 838.35 | 7 | 12 |
2 | 7 | 2006.16 | 41 | 4.61 | 1327 | 251 | 0.46 / 838.60 | 12 | 7 |
3 | 13 | 2056.68 | 20 | 9.82 | 2941 | 578 | 1.04 / 839.18 | 6 | 10 |
4 | 13 | 2034.76 | 20 | 11.72 | 2950 | 691 | 1.73 / 839.87 | 6 | 46 |
5 | 13 | 1967.36 | 20 | 12.01 | 2865 | 688 | 2.42 / 840.56 | 6 | 53 |
6 | 13 | 1878.60 | 20 | 12.19 | 2760 | 673 | 3.09 / 841.23 | 6 | 61 |
7 | 13 | 1359.72 | 20 | 12.74 | 2124 | 541 | 3.63 / 841.77 | 6 | 78 |
8 | 13 | 825.68 | 20 | 13.24 | 1451 | 384 | 4.02 / 842.16 | 6 | 80 |
9 | 13 | 398.08 | 20 | 13.69 | 863 | 236 | 4.26 / 842.39 | 6 | 81 |
10 | 13 | 92.84 | 20 | 14.13 | 433 | 122 | 4.38 / 842.52 | 6 | 72 |
11 | 13 | 22.76 | 20 | 14.25 | 340 | 97 | 4.47 / 842.61 | 6 | 67 |
12 | 8 | 0.08 | 242 | 14.24 | 302 | 1041 | 5.51 / 843.65 | 7 | 134 |
Average= | 4.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.76 | 33 | 14.20 | 451 | 211 | 0.21 / 835.33 | 7 | 11 |
2 | 7 | 1008.08 | 40 | 5.84 | 1436 | 335 | 0.55 / 835.67 | 6 | 9 |
3 | 13 | 959.32 | 20 | 12.79 | 1576 | 403 | 0.95 / 836.07 | 6 | 58 |
4 | 13 | 884.32 | 20 | 13.06 | 1482 | 387 | 1.34 / 836.46 | 6 | 61 |
5 | 13 | 572.56 | 20 | 13.45 | 1093 | 294 | 1.63 / 836.75 | 6 | 67 |
6 | 13 | 127.84 | 20 | 14.00 | 494 | 138 | 1.77 / 836.89 | 6 | 71 |
7 | 13 | 65.16 | 20 | 14.13 | 406 | 115 | 1.88 / 837.01 | 6 | 68 |
8 | 13 | 12.12 | 20 | 14.23 | 332 | 94 | 1.98 / 837.10 | 6 | 67 |
9 | 8 | 0.12 | 235 | 14.16 | 312 | 1038 | 3.02 / 838.14 | 7 | 142 |
Average= | 4.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.20 | 33 | 14.20 | 439 | 206 | 0.21 / 832.25 | 7 | 12 |
2 | 7 | 1011.80 | 41 | 5.75 | 1464 | 345 | 0.55 / 832.60 | 12 | 10 |
3 | 13 | 969.28 | 20 | 12.77 | 1579 | 403 | 0.95 / 833.00 | 6 | 58 |
4 | 13 | 880.92 | 20 | 13.06 | 1478 | 386 | 1.34 / 833.39 | 6 | 63 |
5 | 13 | 785.96 | 20 | 13.20 | 1383 | 365 | 1.71 / 833.75 | 6 | 66 |
6 | 13 | 115.52 | 20 | 14.02 | 484 | 136 | 1.84 / 833.89 | 6 | 68 |
7 | 13 | 63.84 | 20 | 14.11 | 413 | 117 | 1.96 / 834.01 | 6 | 64 |
8 | 8 | 0.20 | 251 | 14.20 | 313 | 1116 | 3.07 / 835.12 | 7 | 129 |
Average= | 4.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.12 | 33 | 14.23 | 442 | 208 | 0.21 / 829.33 | 7 | 10 |
2 | 7 | 997.32 | 41 | 6.27 | 1496 | 385 | 0.59 / 829.72 | 10 | 11 |
3 | 13 | 943.08 | 20 | 13.07 | 1556 | 407 | 1.00 / 830.12 | 6 | 61 |
4 | 13 | 857.48 | 20 | 13.24 | 1445 | 383 | 1.38 / 830.51 | 6 | 64 |
5 | 13 | 537.72 | 20 | 13.56 | 1024 | 278 | 1.66 / 830.78 | 6 | 71 |
6 | 13 | 104.00 | 20 | 14.10 | 452 | 127 | 1.79 / 830.91 | 6 | 69 |
7 | 8 | 0.00 | 268 | 14.24 | 298 | 1137 | 2.92 / 832.05 | 7 | 134 |
Average= | 4.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.16 | 33 | 14.14 | 435 | 203 | 0.20 / 823.81 | 7 | 10 |
2 | 7 | 2005.80 | 40 | 4.61 | 1354 | 250 | 0.45 / 824.05 | 10 | 7 |
3 | 13 | 2058.16 | 20 | 10.18 | 2934 | 597 | 1.05 / 824.65 | 6 | 17 |
4 | 13 | 2028.24 | 20 | 11.83 | 2896 | 685 | 1.74 / 825.34 | 6 | 48 |
5 | 13 | 1954.60 | 20 | 12.01 | 2857 | 686 | 2.42 / 826.02 | 6 | 54 |
6 | 13 | 1865.36 | 20 | 12.21 | 2739 | 669 | 3.09 / 826.69 | 6 | 61 |
7 | 13 | 1444.60 | 20 | 12.66 | 2242 | 568 | 3.66 / 827.26 | 6 | 77 |
8 | 13 | 790.68 | 20 | 13.27 | 1406 | 373 | 4.03 / 827.63 | 6 | 82 |
9 | 13 | 337.84 | 20 | 13.74 | 798 | 219 | 4.25 / 827.85 | 6 | 79 |
10 | 13 | 118.40 | 20 | 14.06 | 493 | 139 | 4.39 / 827.99 | 6 | 76 |
11 | 8 | 0.12 | 261 | 14.23 | 305 | 1133 | 5.52 / 829.12 | 7 | 133 |
Average= | 4.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.28 | 33 | 14.21 | 432 | 203 | 0.20 / 820.81 | 7 | 10 |
2 | 7 | 1003.40 | 41 | 5.73 | 1458 | 343 | 0.55 / 821.16 | 10 | 10 |
3 | 13 | 961.24 | 20 | 12.75 | 1569 | 400 | 0.95 / 821.56 | 6 | 57 |
4 | 13 | 875.36 | 20 | 13.03 | 1467 | 382 | 1.33 / 821.94 | 6 | 63 |
5 | 13 | 468.88 | 20 | 13.55 | 950 | 257 | 1.58 / 822.20 | 6 | 69 |
6 | 13 | 140.60 | 20 | 13.97 | 518 | 145 | 1.73 / 822.34 | 6 | 73 |
7 | 13 | 30.88 | 20 | 14.23 | 348 | 99 | 1.83 / 822.44 | 6 | 64 |
8 | 8 | 0.20 | 272 | 14.20 | 301 | 1163 | 2.99 / 823.60 | 7 | 160 |
Average= | 4.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.60 | 33 | 14.27 | 431 | 203 | 0.20 / 817.95 | 7 | 10 |
2 | 7 | 998.12 | 40 | 5.90 | 1442 | 340 | 0.54 / 818.29 | 10 | 11 |
3 | 13 | 954.20 | 20 | 12.77 | 1569 | 401 | 0.94 / 818.69 | 6 | 58 |
4 | 13 | 874.88 | 20 | 13.07 | 1469 | 384 | 1.33 / 819.07 | 6 | 62 |
5 | 13 | 357.52 | 20 | 13.70 | 786 | 215 | 1.54 / 819.29 | 6 | 70 |
6 | 13 | 145.00 | 20 | 13.99 | 514 | 144 | 1.69 / 819.43 | 6 | 72 |
7 | 13 | 34.64 | 20 | 14.21 | 359 | 102 | 1.79 / 819.54 | 6 | 66 |
8 | 8 | 0.00 | 249 | 14.20 | 304 | 1075 | 2.86 / 820.61 | 7 | 132 |
Average= | 4.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.76 | 33 | 14.29 | 428 | 202 | 0.20 / 815.04 | 7 | 9 |
2 | 7 | 998.80 | 41 | 6.37 | 1497 | 391 | 0.59 / 815.44 | 9 | 14 |
3 | 13 | 945.88 | 20 | 13.06 | 1562 | 408 | 1.00 / 815.84 | 6 | 60 |
4 | 13 | 852.16 | 20 | 13.25 | 1433 | 380 | 1.38 / 816.22 | 6 | 63 |
5 | 13 | 420.08 | 20 | 13.67 | 876 | 239 | 1.62 / 816.46 | 6 | 73 |
6 | 13 | 105.52 | 20 | 14.10 | 460 | 130 | 1.75 / 816.59 | 6 | 70 |
7 | 13 | 13.16 | 20 | 14.30 | 325 | 93 | 1.84 / 816.69 | 6 | 63 |
8 | 8 | 0.04 | 247 | 14.23 | 302 | 1061 | 2.90 / 817.75 | 7 | 135 |
Average= | 4.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.44 | 33 | 14.19 | 440 | 206 | 0.21 / 809.61 | 7 | 9 |
2 | 7 | 2006.32 | 40 | 4.60 | 1309 | 241 | 0.45 / 809.85 | 9 | 7 |
3 | 13 | 2059.68 | 20 | 9.99 | 2921 | 584 | 1.03 / 810.43 | 6 | 11 |
4 | 13 | 2037.48 | 20 | 11.74 | 2953 | 693 | 1.72 / 811.13 | 6 | 48 |
5 | 13 | 1966.20 | 20 | 12.02 | 2854 | 686 | 2.41 / 811.81 | 6 | 51 |
6 | 13 | 1772.28 | 20 | 12.31 | 2656 | 654 | 3.06 / 812.47 | 6 | 65 |
7 | 13 | 1350.88 | 20 | 12.77 | 2093 | 535 | 3.60 / 813.00 | 6 | 74 |
8 | 13 | 826.08 | 20 | 13.29 | 1383 | 368 | 3.97 / 813.37 | 6 | 65 |
9 | 13 | 278.12 | 20 | 13.84 | 695 | 192 | 4.16 / 813.56 | 6 | 73 |
10 | 13 | 95.88 | 20 | 14.12 | 455 | 128 | 4.29 / 813.69 | 6 | 73 |
11 | 13 | 25.12 | 20 | 14.27 | 346 | 99 | 4.39 / 813.79 | 6 | 68 |
12 | 8 | 0.08 | 242 | 14.25 | 306 | 1055 | 5.44 / 814.84 | 7 | 133 |
Average= | 4.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.00 | 33 | 14.23 | 439 | 206 | 0.21 / 806.75 | 7 | 9 |
2 | 7 | 1005.04 | 40 | 5.64 | 1416 | 319 | 0.53 / 807.07 | 9 | 9 |
3 | 13 | 951.72 | 20 | 12.78 | 1556 | 398 | 0.92 / 807.46 | 6 | 57 |
4 | 13 | 868.32 | 20 | 13.07 | 1456 | 381 | 1.30 / 807.84 | 6 | 61 |
5 | 13 | 439.64 | 20 | 13.58 | 908 | 247 | 1.55 / 808.09 | 6 | 69 |
6 | 13 | 121.12 | 20 | 14.03 | 495 | 139 | 1.69 / 808.23 | 6 | 68 |
7 | 13 | 37.16 | 20 | 14.22 | 355 | 101 | 1.79 / 808.33 | 6 | 63 |
8 | 8 | 0.16 | 251 | 14.22 | 300 | 1071 | 2.86 / 809.40 | 7 | 133 |
Average= | 4.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.72 | 33 | 14.25 | 435 | 205 | 0.20 / 803.72 | 7 | 10 |
2 | 7 | 1007.56 | 41 | 5.88 | 1489 | 359 | 0.56 / 804.08 | 10 | 13 |
3 | 13 | 959.40 | 20 | 12.85 | 1563 | 402 | 0.97 / 804.48 | 6 | 57 |
4 | 13 | 877.48 | 20 | 13.09 | 1475 | 386 | 1.35 / 804.86 | 6 | 62 |
5 | 13 | 675.20 | 20 | 13.38 | 1221 | 327 | 1.68 / 805.19 | 6 | 68 |
6 | 13 | 121.76 | 20 | 14.06 | 475 | 134 | 1.81 / 805.32 | 6 | 69 |
7 | 13 | 63.64 | 20 | 14.18 | 400 | 113 | 1.93 / 805.44 | 6 | 64 |
8 | 8 | 0.12 | 254 | 14.23 | 305 | 1102 | 3.03 / 806.54 | 7 | 133 |
Average= | 4.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.08 | 33 | 14.24 | 448 | 211 | 0.21 / 800.88 | 7 | 8 |
2 | 7 | 1006.80 | 40 | 6.62 | 1531 | 405 | 0.62 / 801.28 | 6 | 16 |
3 | 13 | 934.56 | 20 | 13.14 | 1546 | 406 | 1.02 / 801.69 | 6 | 61 |
4 | 13 | 843.32 | 20 | 13.29 | 1427 | 379 | 1.40 / 802.07 | 6 | 62 |
5 | 13 | 304.44 | 20 | 13.82 | 723 | 200 | 1.60 / 802.27 | 6 | 74 |
6 | 13 | 96.92 | 20 | 14.14 | 444 | 126 | 1.73 / 802.39 | 6 | 70 |
7 | 13 | 23.04 | 20 | 14.28 | 335 | 96 | 1.82 / 802.49 | 6 | 63 |
8 | 8 | 0.04 | 242 | 14.26 | 297 | 1025 | 2.85 / 803.51 | 7 | 130 |
Average= | 4.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.56 | 33 | 14.25 | 426 | 200 | 0.20 / 795.42 | 7 | 10 |
2 | 7 | 2010.48 | 41 | 4.62 | 1399 | 265 | 0.47 / 795.68 | 10 | 7 |
3 | 13 | 2063.32 | 20 | 10.67 | 2944 | 628 | 1.09 / 796.31 | 6 | 24 |
4 | 13 | 2036.44 | 20 | 11.84 | 2935 | 695 | 1.79 / 797.01 | 6 | 48 |
5 | 13 | 1966.76 | 20 | 12.09 | 2846 | 688 | 2.48 / 797.69 | 6 | 54 |
6 | 13 | 1663.60 | 20 | 12.48 | 2483 | 620 | 3.10 / 798.31 | 6 | 71 |
7 | 13 | 1361.04 | 20 | 12.78 | 2118 | 541 | 3.64 / 798.86 | 6 | 79 |
8 | 13 | 938.48 | 20 | 13.21 | 1553 | 410 | 4.05 / 799.27 | 6 | 77 |
9 | 13 | 171.36 | 20 | 14.00 | 563 | 158 | 4.21 / 799.42 | 6 | 74 |
10 | 13 | 57.12 | 20 | 14.23 | 389 | 111 | 4.32 / 799.53 | 6 | 67 |
11 | 13 | 29.72 | 20 | 14.28 | 350 | 100 | 4.42 / 799.63 | 6 | 66 |
12 | 8 | 0.08 | 237 | 14.27 | 305 | 1032 | 5.45 / 800.67 | 7 | 135 |
Average= | 4.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.16 | 33 | 14.25 | 439 | 206 | 0.21 / 792.46 | 7 | 10 |
2 | 7 | 1007.24 | 40 | 5.99 | 1459 | 350 | 0.56 / 792.81 | 10 | 13 |
3 | 13 | 965.64 | 20 | 12.82 | 1576 | 404 | 0.96 / 793.21 | 6 | 57 |
4 | 13 | 882.80 | 20 | 13.08 | 1471 | 385 | 1.34 / 793.60 | 6 | 63 |
5 | 13 | 567.40 | 20 | 13.47 | 1068 | 288 | 1.63 / 793.89 | 6 | 69 |
6 | 13 | 131.88 | 20 | 14.02 | 497 | 139 | 1.77 / 794.03 | 6 | 70 |
7 | 13 | 39.08 | 20 | 14.24 | 364 | 104 | 1.88 / 794.13 | 6 | 63 |
8 | 8 | 0.16 | 251 | 14.21 | 305 | 1088 | 2.96 / 795.22 | 7 | 137 |
Average= | 4.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.84 | 33 | 14.20 | 438 | 205 | 0.21 / 789.54 | 7 | 11 |
2 | 7 | 1009.40 | 41 | 6.15 | 1454 | 367 | 0.57 / 789.90 | 6 | 15 |
3 | 13 | 961.68 | 20 | 12.86 | 1576 | 405 | 0.98 / 790.31 | 6 | 59 |
4 | 13 | 876.04 | 20 | 13.09 | 1488 | 390 | 1.37 / 790.70 | 6 | 62 |
5 | 13 | 365.20 | 20 | 13.67 | 822 | 225 | 1.59 / 790.92 | 6 | 71 |
6 | 13 | 154.80 | 20 | 13.99 | 541 | 151 | 1.74 / 791.08 | 6 | 70 |
7 | 13 | 40.72 | 20 | 14.22 | 369 | 105 | 1.85 / 791.18 | 6 | 65 |
8 | 8 | 0.12 | 249 | 14.23 | 303 | 1074 | 2.92 / 792.25 | 7 | 131 |
Average= | 4.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.92 | 33 | 14.24 | 433 | 203 | 0.20 / 786.60 | 7 | 11 |
2 | 7 | 1013.44 | 41 | 5.89 | 1442 | 348 | 0.55 / 786.95 | 11 | 13 |
3 | 13 | 973.00 | 20 | 12.82 | 1582 | 406 | 0.96 / 787.35 | 6 | 58 |
4 | 13 | 889.44 | 20 | 13.07 | 1483 | 388 | 1.34 / 787.74 | 6 | 64 |
5 | 13 | 464.40 | 20 | 13.58 | 936 | 254 | 1.60 / 787.99 | 6 | 70 |
6 | 13 | 137.12 | 20 | 14.03 | 501 | 141 | 1.74 / 788.13 | 6 | 70 |
7 | 13 | 69.84 | 20 | 14.17 | 405 | 115 | 1.85 / 788.25 | 6 | 67 |
8 | 8 | 0.00 | 249 | 14.22 | 306 | 1083 | 2.94 / 789.33 | 7 | 130 |
Average= | 4.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.76 | 33 | 14.21 | 439 | 206 | 0.21 / 783.62 | 7 | 11 |
2 | 7 | 1003.68 | 41 | 7.40 | 1549 | 470 | 0.68 / 784.09 | 6 | 23 |
3 | 13 | 947.32 | 20 | 12.93 | 1561 | 404 | 1.08 / 784.49 | 6 | 60 |
4 | 13 | 861.16 | 20 | 13.15 | 1450 | 381 | 1.46 / 784.87 | 6 | 65 |
5 | 13 | 330.28 | 20 | 13.75 | 763 | 210 | 1.67 / 785.08 | 6 | 70 |
6 | 13 | 111.52 | 20 | 14.06 | 477 | 134 | 1.80 / 785.22 | 6 | 72 |
7 | 13 | 27.64 | 20 | 14.24 | 353 | 101 | 1.91 / 785.32 | 6 | 66 |
8 | 8 | 0.16 | 244 | 14.20 | 311 | 1078 | 2.98 / 786.39 | 6 | 133 |
Average= | 4.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.24 | 33 | 14.22 | 437 | 205 | 0.21 / 780.73 | 7 | 11 |
2 | 7 | 1004.80 | 41 | 5.84 | 1437 | 344 | 0.55 / 781.08 | 11 | 12 |
3 | 13 | 957.08 | 20 | 12.85 | 1570 | 403 | 0.95 / 781.48 | 6 | 58 |
4 | 13 | 880.20 | 20 | 13.10 | 1468 | 385 | 1.34 / 781.87 | 6 | 64 |
5 | 13 | 465.04 | 20 | 13.57 | 934 | 253 | 1.59 / 782.12 | 6 | 69 |
6 | 13 | 83.32 | 20 | 14.16 | 415 | 118 | 1.71 / 782.24 | 6 | 68 |
7 | 13 | 46.68 | 20 | 14.22 | 375 | 107 | 1.81 / 782.34 | 6 | 66 |
8 | 8 | 0.04 | 249 | 14.21 | 302 | 1069 | 2.88 / 783.41 | 7 | 131 |
Average= | 4.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.52 | 33 | 14.25 | 433 | 204 | 0.20 / 777.79 | 7 | 12 |
2 | 7 | 1006.72 | 40 | 6.23 | 1439 | 359 | 0.56 / 778.14 | 6 | 16 |
3 | 13 | 947.20 | 20 | 12.92 | 1560 | 403 | 0.97 / 778.55 | 6 | 59 |
4 | 13 | 871.80 | 20 | 13.11 | 1474 | 386 | 1.35 / 778.93 | 6 | 61 |
5 | 13 | 540.56 | 20 | 13.50 | 1054 | 285 | 1.64 / 779.22 | 6 | 70 |
6 | 13 | 108.52 | 20 | 14.09 | 468 | 132 | 1.77 / 779.35 | 6 | 70 |
7 | 13 | 25.12 | 20 | 14.27 | 347 | 99 | 1.87 / 779.45 | 6 | 65 |
8 | 8 | 0.04 | 247 | 14.22 | 307 | 1078 | 2.95 / 780.53 | 7 | 134 |
Average= | 4.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.12 | 33 | 14.23 | 421 | 198 | 0.20 / 774.88 | 7 | 14 |
2 | 7 | 1004.08 | 41 | 6.37 | 1460 | 381 | 0.58 / 775.26 | 14 | 16 |
3 | 13 | 958.96 | 20 | 12.85 | 1573 | 404 | 0.98 / 775.67 | 6 | 59 |
4 | 13 | 860.72 | 20 | 13.10 | 1445 | 379 | 1.36 / 776.04 | 6 | 62 |
5 | 13 | 435.04 | 20 | 13.60 | 910 | 248 | 1.61 / 776.29 | 6 | 69 |
6 | 13 | 103.36 | 20 | 14.08 | 458 | 129 | 1.74 / 776.42 | 6 | 72 |
7 | 13 | 26.00 | 20 | 14.25 | 341 | 97 | 1.84 / 776.52 | 6 | 69 |
8 | 8 | 0.12 | 246 | 14.19 | 305 | 1065 | 2.90 / 777.58 | 7 | 136 |
Average= | 4.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.32 | 33 | 14.21 | 443 | 208 | 0.21 / 772.05 | 7 | 15 |
2 | 7 | 1002.96 | 41 | 6.75 | 1530 | 423 | 0.63 / 772.48 | 6 | 23 |
3 | 13 | 935.96 | 20 | 12.96 | 1546 | 401 | 1.03 / 772.88 | 6 | 61 |
4 | 13 | 847.52 | 20 | 13.18 | 1435 | 378 | 1.41 / 773.25 | 6 | 63 |
5 | 13 | 206.80 | 20 | 13.89 | 606 | 168 | 1.58 / 773.42 | 6 | 72 |
6 | 13 | 57.40 | 20 | 14.18 | 392 | 111 | 1.69 / 773.53 | 6 | 69 |
7 | 8 | 0.04 | 261 | 14.19 | 310 | 1148 | 2.84 / 774.68 | 6 | 135 |
Average= | 4.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.00 | 32 | 14.20 | 438 | 199 | 0.20 / 769.12 | 7 | 15 |
2 | 7 | 1004.84 | 41 | 6.37 | 1476 | 385 | 0.58 / 769.51 | 6 | 18 |
3 | 13 | 949.92 | 20 | 12.90 | 1561 | 403 | 0.99 / 769.91 | 6 | 60 |
4 | 13 | 869.88 | 20 | 13.14 | 1460 | 384 | 1.37 / 770.29 | 6 | 63 |
5 | 13 | 439.28 | 20 | 13.62 | 924 | 252 | 1.62 / 770.55 | 6 | 73 |
6 | 13 | 103.48 | 20 | 14.08 | 462 | 130 | 1.75 / 770.68 | 6 | 73 |
7 | 13 | 53.44 | 20 | 14.18 | 396 | 112 | 1.87 / 770.79 | 6 | 71 |
8 | 8 | 0.12 | 242 | 14.18 | 308 | 1057 | 2.92 / 771.84 | 6 | 129 |
Average= | 4.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.64 | 32 | 14.21 | 442 | 201 | 0.20 / 766.25 | 7 | 14 |
2 | 7 | 1027.88 | 41 | 6.14 | 1471 | 370 | 0.57 / 766.62 | 6 | 16 |
3 | 13 | 976.88 | 20 | 12.88 | 1599 | 412 | 0.98 / 767.03 | 6 | 59 |
4 | 13 | 800.52 | 20 | 13.21 | 1381 | 365 | 1.35 / 767.40 | 6 | 66 |
5 | 13 | 380.76 | 20 | 13.70 | 824 | 226 | 1.57 / 767.62 | 6 | 74 |
6 | 13 | 79.88 | 20 | 14.15 | 411 | 116 | 1.69 / 767.74 | 6 | 71 |
7 | 13 | 44.04 | 20 | 14.20 | 372 | 106 | 1.80 / 767.84 | 6 | 69 |
8 | 8 | 0.04 | 244 | 14.18 | 312 | 1079 | 2.88 / 768.92 | 6 | 132 |
Average= | 4.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.00 | 33 | 14.24 | 429 | 202 | 0.20 / 763.29 | 7 | 12 |
2 | 7 | 1009.52 | 40 | 6.26 | 1464 | 367 | 0.57 / 763.66 | 12 | 15 |
3 | 13 | 952.04 | 20 | 12.86 | 1565 | 403 | 0.97 / 764.06 | 6 | 58 |
4 | 13 | 863.72 | 20 | 13.11 | 1453 | 381 | 1.35 / 764.44 | 6 | 64 |
5 | 13 | 550.20 | 20 | 13.50 | 1064 | 287 | 1.64 / 764.73 | 6 | 70 |
6 | 13 | 98.72 | 20 | 14.07 | 468 | 132 | 1.77 / 764.86 | 6 | 71 |
7 | 8 | 0.12 | 265 | 14.19 | 315 | 1185 | 2.96 / 766.05 | 6 | 135 |
Average= | 4.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.56 | 32 | 14.26 | 436 | 199 | 0.20 / 760.49 | 7 | 11 |
2 | 7 | 1011.76 | 40 | 6.68 | 1529 | 409 | 0.61 / 760.90 | 6 | 21 |
3 | 13 | 953.84 | 20 | 12.95 | 1569 | 406 | 1.01 / 761.30 | 6 | 61 |
4 | 13 | 864.72 | 20 | 13.17 | 1454 | 383 | 1.40 / 761.68 | 6 | 61 |
5 | 13 | 218.44 | 20 | 13.90 | 609 | 169 | 1.57 / 761.85 | 6 | 75 |
6 | 13 | 62.08 | 20 | 14.19 | 387 | 110 | 1.68 / 761.96 | 6 | 72 |
7 | 8 | 0.08 | 258 | 14.20 | 308 | 1128 | 2.80 / 763.09 | 6 | 137 |
Average= | 4.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.40 | 32 | 14.28 | 430 | 196 | 0.20 / 757.54 | 7 | 12 |
2 | 7 | 1006.32 | 41 | 5.89 | 1462 | 353 | 0.55 / 757.90 | 12 | 13 |
3 | 13 | 954.24 | 20 | 12.88 | 1572 | 405 | 0.95 / 758.30 | 6 | 59 |
4 | 13 | 881.96 | 20 | 13.13 | 1476 | 388 | 1.34 / 758.69 | 6 | 65 |
5 | 13 | 556.88 | 20 | 13.53 | 1053 | 285 | 1.63 / 758.97 | 6 | 69 |
6 | 13 | 113.44 | 20 | 14.07 | 471 | 133 | 1.76 / 759.11 | 6 | 70 |
7 | 8 | 0.08 | 265 | 14.21 | 314 | 1182 | 2.94 / 760.29 | 7 | 139 |
Average= | 4.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.92 | 32 | 14.25 | 429 | 196 | 0.20 / 754.60 | 7 | 11 |
2 | 7 | 1014.60 | 40 | 6.49 | 1482 | 385 | 0.58 / 754.98 | 6 | 20 |
3 | 13 | 956.80 | 20 | 12.91 | 1576 | 407 | 0.99 / 755.39 | 6 | 60 |
4 | 13 | 861.00 | 20 | 13.16 | 1474 | 388 | 1.38 / 755.78 | 6 | 63 |
5 | 13 | 432.56 | 20 | 13.67 | 911 | 249 | 1.62 / 756.03 | 6 | 71 |
6 | 13 | 103.40 | 20 | 14.09 | 472 | 133 | 1.76 / 756.16 | 6 | 73 |
7 | 8 | 0.16 | 263 | 14.22 | 317 | 1186 | 2.94 / 757.35 | 7 | 129 |
Average= | 4.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.52 | 33 | 14.35 | 431 | 204 | 0.20 / 751.78 | 7 | 10 |
2 | 7 | 1003.88 | 41 | 6.89 | 1561 | 441 | 0.65 / 752.22 | 10 | 22 |
3 | 13 | 939.76 | 20 | 13.18 | 1549 | 408 | 1.05 / 752.63 | 6 | 65 |
4 | 13 | 843.68 | 20 | 13.32 | 1426 | 380 | 1.43 / 753.01 | 6 | 66 |
5 | 13 | 196.00 | 20 | 13.98 | 583 | 163 | 1.60 / 753.17 | 6 | 77 |
6 | 13 | 52.08 | 20 | 14.23 | 390 | 111 | 1.71 / 753.28 | 6 | 70 |
7 | 8 | 0.12 | 256 | 14.24 | 308 | 1123 | 2.83 / 754.40 | 7 | 137 |
Average= | 4.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.08 | 32 | 14.24 | 440 | 200 | 0.20 / 746.36 | 7 | 12 |
2 | 7 | 2004.60 | 40 | 4.67 | 1550 | 290 | 0.49 / 746.65 | 12 | 7 |
3 | 13 | 2050.24 | 20 | 11.24 | 2928 | 658 | 1.15 / 747.30 | 6 | 35 |
4 | 13 | 2014.88 | 20 | 11.97 | 2909 | 696 | 1.84 / 748.00 | 6 | 51 |
5 | 13 | 1942.04 | 20 | 12.19 | 2854 | 696 | 2.54 / 748.70 | 6 | 57 |
6 | 13 | 1843.32 | 20 | 12.36 | 2718 | 672 | 3.21 / 749.37 | 6 | 65 |
7 | 13 | 1312.12 | 20 | 12.90 | 2060 | 531 | 3.74 / 749.90 | 6 | 80 |
8 | 13 | 564.84 | 20 | 13.57 | 1101 | 299 | 4.04 / 750.20 | 6 | 82 |
9 | 13 | 151.56 | 20 | 14.04 | 538 | 151 | 4.19 / 750.35 | 6 | 79 |
10 | 13 | 38.28 | 20 | 14.27 | 369 | 105 | 4.30 / 750.45 | 6 | 75 |
11 | 8 | 0.08 | 251 | 14.24 | 313 | 1119 | 5.42 / 751.57 | 6 | 136 |
Average= | 4.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.88 | 32 | 14.29 | 426 | 195 | 0.19 / 743.43 | 7 | 12 |
2 | 7 | 1018.20 | 40 | 6.08 | 1477 | 359 | 0.55 / 743.79 | 6 | 14 |
3 | 13 | 976.16 | 20 | 12.88 | 1584 | 408 | 0.96 / 744.20 | 6 | 60 |
4 | 13 | 892.72 | 20 | 13.11 | 1496 | 392 | 1.35 / 744.59 | 6 | 64 |
5 | 13 | 486.68 | 20 | 13.58 | 989 | 269 | 1.62 / 744.86 | 6 | 71 |
6 | 13 | 76.48 | 20 | 14.15 | 428 | 121 | 1.74 / 744.98 | 6 | 74 |
7 | 13 | 2.84 | 20 | 14.30 | 321 | 92 | 1.84 / 745.07 | 6 | 75 |
8 | 8 | 0.12 | 244 | 14.21 | 313 | 1085 | 2.92 / 746.16 | 7 | 132 |
Average= | 4.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.64 | 32 | 14.28 | 446 | 204 | 0.20 / 740.51 | 7 | 11 |
2 | 7 | 1011.72 | 41 | 6.32 | 1472 | 381 | 0.59 / 740.89 | 6 | 18 |
3 | 13 | 959.84 | 20 | 12.94 | 1576 | 408 | 0.99 / 741.30 | 6 | 62 |
4 | 13 | 873.48 | 20 | 13.19 | 1468 | 387 | 1.38 / 741.69 | 6 | 66 |
5 | 13 | 453.00 | 20 | 13.66 | 937 | 256 | 1.64 / 741.94 | 6 | 72 |
6 | 13 | 68.80 | 20 | 14.19 | 415 | 118 | 1.75 / 742.06 | 6 | 71 |
7 | 13 | 15.44 | 20 | 14.29 | 338 | 97 | 1.85 / 742.16 | 6 | 69 |
8 | 8 | 0.16 | 244 | 14.22 | 310 | 1076 | 2.93 / 743.23 | 7 | 134 |
Average= | 4.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.92 | 32 | 14.30 | 433 | 198 | 0.20 / 737.67 | 7 | 10 |
2 | 3 | 1020.76 | 1 | 10.55 | 1655 | 17 | 0.22 / 737.68 | 6 | 6 |
3 | 7 | 1015.28 | 40 | 7.73 | 1564 | 484 | 0.70 / 738.17 | 6 | 31 |
4 | 13 | 942.96 | 20 | 13.20 | 1561 | 412 | 1.11 / 738.58 | 6 | 64 |
5 | 13 | 750.16 | 20 | 13.45 | 1307 | 352 | 1.46 / 738.93 | 6 | 68 |
6 | 13 | 181.52 | 20 | 14.06 | 552 | 155 | 1.62 / 739.09 | 6 | 77 |
7 | 13 | 47.40 | 20 | 14.28 | 372 | 106 | 1.72 / 739.19 | 6 | 70 |
8 | 13 | 23.92 | 20 | 14.27 | 351 | 100 | 1.82 / 739.29 | 6 | 69 |
9 | 8 | 0.04 | 232 | 14.26 | 307 | 1016 | 2.84 / 740.31 | 7 | 133 |
Average= | 5.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.56 | 32 | 14.32 | 442 | 203 | 0.20 / 732.17 | 7 | 11 |
2 | 7 | 2008.64 | 40 | 4.66 | 1535 | 286 | 0.49 / 732.46 | 6 | 7 |
3 | 13 | 2056.64 | 20 | 11.45 | 2939 | 673 | 1.16 / 733.13 | 6 | 41 |
4 | 13 | 2020.36 | 20 | 12.03 | 2937 | 707 | 1.87 / 733.84 | 6 | 53 |
5 | 13 | 1953.20 | 20 | 12.23 | 2870 | 702 | 2.57 / 734.54 | 6 | 59 |
6 | 13 | 1863.64 | 20 | 12.39 | 2765 | 685 | 3.26 / 735.23 | 6 | 64 |
7 | 13 | 1223.52 | 20 | 13.01 | 1922 | 500 | 3.76 / 735.73 | 6 | 77 |
8 | 13 | 787.56 | 20 | 13.42 | 1337 | 359 | 4.11 / 736.08 | 6 | 76 |
9 | 13 | 143.00 | 20 | 14.10 | 526 | 148 | 4.26 / 736.23 | 6 | 76 |
10 | 13 | 76.44 | 20 | 14.21 | 426 | 121 | 4.38 / 736.35 | 6 | 73 |
11 | 8 | 0.12 | 254 | 14.29 | 307 | 1114 | 5.50 / 737.47 | 7 | 131 |
Average= | 5.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.24 | 32 | 14.32 | 438 | 201 | 0.20 / 729.27 | 7 | 12 |
2 | 7 | 1021.28 | 40 | 6.54 | 1494 | 391 | 0.59 / 729.67 | 6 | 19 |
3 | 13 | 965.64 | 20 | 12.95 | 1587 | 411 | 1.00 / 730.08 | 6 | 61 |
4 | 13 | 886.28 | 20 | 13.17 | 1490 | 392 | 1.40 / 730.47 | 6 | 63 |
5 | 13 | 358.44 | 20 | 13.75 | 820 | 225 | 1.62 / 730.69 | 6 | 72 |
6 | 13 | 87.96 | 20 | 14.19 | 438 | 124 | 1.74 / 730.82 | 6 | 65 |
7 | 8 | 0.08 | 265 | 14.28 | 304 | 1150 | 2.90 / 731.97 | 7 | 132 |
Average= | 5.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.28 | 32 | 14.25 | 436 | 199 | 0.20 / 726.34 | 7 | 13 |
2 | 7 | 1017.60 | 40 | 6.43 | 1499 | 386 | 0.58 / 726.73 | 6 | 19 |
3 | 13 | 959.16 | 20 | 12.93 | 1574 | 407 | 0.99 / 727.14 | 6 | 60 |
4 | 13 | 868.68 | 20 | 13.17 | 1478 | 389 | 1.38 / 727.52 | 6 | 65 |
5 | 13 | 438.96 | 20 | 13.69 | 916 | 251 | 1.63 / 727.78 | 6 | 72 |
6 | 13 | 113.24 | 20 | 14.12 | 477 | 135 | 1.77 / 727.91 | 6 | 71 |
7 | 8 | 0.04 | 265 | 14.26 | 308 | 1164 | 2.93 / 729.07 | 7 | 132 |
Average= | 5.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.96 | 32 | 14.33 | 437 | 200 | 0.20 / 723.53 | 7 | 11 |
2 | 7 | 1017.36 | 41 | 7.34 | 1565 | 471 | 0.67 / 724.00 | 6 | 25 |
3 | 13 | 946.56 | 20 | 13.22 | 1566 | 414 | 1.09 / 724.41 | 6 | 64 |
4 | 13 | 655.72 | 20 | 13.55 | 1184 | 321 | 1.41 / 724.73 | 6 | 70 |
5 | 13 | 231.88 | 20 | 13.99 | 639 | 179 | 1.59 / 724.91 | 6 | 75 |
6 | 13 | 70.52 | 20 | 14.26 | 409 | 117 | 1.70 / 725.03 | 6 | 68 |
7 | 8 | 0.16 | 256 | 14.29 | 305 | 1116 | 2.82 / 726.14 | 7 | 132 |
Average= | 5.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.04 | 32 | 14.36 | 434 | 199 | 0.20 / 717.90 | 7 | 11 |
2 | 7 | 2009.80 | 41 | 4.73 | 1845 | 358 | 0.56 / 718.26 | 11 | 7 |
3 | 13 | 2059.96 | 20 | 12.20 | 2944 | 718 | 1.28 / 718.97 | 6 | 49 |
4 | 13 | 2019.96 | 20 | 12.48 | 2929 | 731 | 2.01 / 719.70 | 6 | 57 |
5 | 13 | 1946.64 | 20 | 12.61 | 2835 | 715 | 2.72 / 720.42 | 6 | 63 |
6 | 13 | 1849.36 | 20 | 12.67 | 2733 | 693 | 3.41 / 721.11 | 6 | 69 |
7 | 13 | 1195.36 | 20 | 13.17 | 1919 | 505 | 3.92 / 721.62 | 6 | 87 |
8 | 13 | 639.08 | 20 | 13.61 | 1199 | 326 | 4.25 / 721.94 | 6 | 87 |
9 | 13 | 190.84 | 20 | 14.06 | 593 | 167 | 4.41 / 722.11 | 6 | 81 |
10 | 13 | 46.20 | 20 | 14.31 | 379 | 108 | 4.52 / 722.22 | 6 | 69 |
11 | 8 | 0.04 | 249 | 14.30 | 311 | 1107 | 5.63 / 723.33 | 7 | 130 |
Average= | 5.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.64 | 32 | 14.32 | 439 | 201 | 0.20 / 712.42 | 7 | 12 |
2 | 7 | 2002.08 | 40 | 4.71 | 1757 | 331 | 0.53 / 712.75 | 12 | 7 |
3 | 13 | 2048.84 | 20 | 12.16 | 2950 | 717 | 1.25 / 713.47 | 6 | 47 |
4 | 13 | 2001.76 | 20 | 12.49 | 2896 | 723 | 1.97 / 714.19 | 6 | 58 |
5 | 13 | 1905.88 | 20 | 12.62 | 2779 | 701 | 2.67 / 714.89 | 6 | 66 |
6 | 13 | 1692.12 | 20 | 12.80 | 2533 | 648 | 3.32 / 715.54 | 6 | 74 |
7 | 13 | 1266.08 | 20 | 13.11 | 2014 | 528 | 3.85 / 716.07 | 6 | 84 |
8 | 13 | 487.32 | 20 | 13.78 | 994 | 274 | 4.12 / 716.34 | 6 | 84 |
9 | 13 | 167.80 | 20 | 14.10 | 558 | 157 | 4.28 / 716.50 | 6 | 80 |
10 | 13 | 40.28 | 20 | 14.36 | 363 | 104 | 4.39 / 716.60 | 6 | 67 |
11 | 8 | 0.16 | 249 | 14.33 | 307 | 1095 | 5.48 / 717.70 | 7 | 130 |
Average= | 5.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.92 | 32 | 14.39 | 424 | 195 | 0.20 / 706.82 | 7 | 11 |
2 | 7 | 2004.76 | 41 | 4.73 | 1830 | 355 | 0.55 / 707.18 | 11 | 7 |
3 | 13 | 2050.88 | 20 | 12.21 | 2949 | 720 | 1.27 / 707.90 | 6 | 50 |
4 | 13 | 2013.00 | 20 | 12.50 | 2913 | 728 | 2.00 / 708.63 | 6 | 59 |
5 | 13 | 1946.48 | 20 | 12.63 | 2827 | 714 | 2.71 / 709.34 | 6 | 63 |
6 | 13 | 1856.48 | 20 | 12.72 | 2718 | 691 | 3.40 / 710.03 | 6 | 68 |
7 | 13 | 1215.88 | 20 | 13.16 | 1930 | 508 | 3.91 / 710.54 | 6 | 84 |
8 | 13 | 649.76 | 20 | 13.62 | 1207 | 329 | 4.24 / 710.87 | 6 | 86 |
9 | 13 | 195.76 | 20 | 14.07 | 602 | 169 | 4.41 / 711.04 | 6 | 79 |
10 | 8 | 0.08 | 265 | 14.32 | 310 | 1176 | 5.59 / 712.22 | 7 | 132 |
Average= | 5.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.28 | 32 | 14.37 | 437 | 201 | 0.20 / 701.26 | 7 | 10 |
2 | 7 | 2009.16 | 40 | 4.75 | 1887 | 359 | 0.56 / 701.62 | 10 | 7 |
3 | 13 | 2057.28 | 20 | 12.24 | 2961 | 725 | 1.28 / 702.35 | 6 | 49 |
4 | 13 | 2021.32 | 20 | 12.50 | 2902 | 725 | 2.01 / 703.07 | 6 | 59 |
5 | 13 | 1955.32 | 20 | 12.60 | 2850 | 718 | 2.73 / 703.79 | 6 | 63 |
6 | 13 | 1861.16 | 20 | 12.72 | 2737 | 696 | 3.42 / 704.49 | 6 | 68 |
7 | 13 | 1177.76 | 20 | 13.18 | 1887 | 497 | 3.92 / 704.98 | 6 | 86 |
8 | 13 | 535.16 | 20 | 13.73 | 1054 | 289 | 4.21 / 705.27 | 6 | 80 |
9 | 13 | 207.92 | 20 | 14.05 | 618 | 174 | 4.38 / 705.45 | 6 | 80 |
10 | 13 | 12.32 | 20 | 14.38 | 324 | 93 | 4.48 / 705.54 | 6 | 64 |
11 | 8 | 0.04 | 247 | 14.32 | 308 | 1089 | 5.57 / 706.63 | 7 | 133 |
Average= | 5.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.52 | 32 | 14.38 | 428 | 197 | 0.20 / 695.74 | 7 | 10 |
2 | 7 | 2009.24 | 41 | 4.76 | 1963 | 383 | 0.58 / 696.12 | 10 | 7 |
3 | 13 | 2047.08 | 20 | 12.27 | 2956 | 725 | 1.31 / 696.85 | 6 | 50 |
4 | 13 | 1994.68 | 20 | 12.52 | 2886 | 723 | 2.03 / 697.57 | 6 | 59 |
5 | 13 | 1917.96 | 20 | 12.67 | 2779 | 704 | 2.73 / 698.28 | 6 | 64 |
6 | 13 | 1824.64 | 20 | 12.71 | 2703 | 687 | 3.42 / 698.96 | 6 | 68 |
7 | 13 | 1182.56 | 20 | 13.17 | 1899 | 500 | 3.92 / 699.46 | 6 | 85 |
8 | 13 | 544.96 | 20 | 13.73 | 1063 | 292 | 4.21 / 699.76 | 6 | 81 |
9 | 13 | 119.88 | 20 | 14.20 | 479 | 136 | 4.35 / 699.89 | 6 | 72 |
10 | 8 | 0.12 | 270 | 14.35 | 302 | 1170 | 5.52 / 701.06 | 7 | 134 |
Average= | 5.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.92 | 32 | 14.35 | 438 | 201 | 0.20 / 690.19 | 7 | 10 |
2 | 7 | 2009.80 | 40 | 4.80 | 2087 | 401 | 0.60 / 690.59 | 10 | 6 |
3 | 13 | 2055.32 | 20 | 12.31 | 2942 | 724 | 1.33 / 691.31 | 6 | 49 |
4 | 13 | 2006.56 | 20 | 12.54 | 2889 | 725 | 2.05 / 692.04 | 6 | 59 |
5 | 13 | 1917.44 | 20 | 12.64 | 2799 | 708 | 2.76 / 692.74 | 6 | 65 |
6 | 13 | 1729.28 | 20 | 12.80 | 2590 | 663 | 3.42 / 693.41 | 6 | 73 |
7 | 13 | 1188.04 | 20 | 13.18 | 1901 | 501 | 3.92 / 693.91 | 6 | 86 |
8 | 13 | 531.40 | 20 | 13.73 | 1046 | 287 | 4.21 / 694.20 | 6 | 84 |
9 | 13 | 191.28 | 20 | 14.09 | 594 | 167 | 4.38 / 694.36 | 6 | 81 |
10 | 13 | 19.92 | 20 | 14.37 | 332 | 95 | 4.47 / 694.46 | 6 | 67 |
11 | 8 | 0.28 | 249 | 14.34 | 304 | 1085 | 5.56 / 695.54 | 7 | 131 |
Average= | 5.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.92 | 32 | 14.32 | 443 | 203 | 0.20 / 684.63 | 7 | 10 |
2 | 7 | 2000.88 | 40 | 4.85 | 2332 | 452 | 0.66 / 685.09 | 10 | 6 |
3 | 13 | 2045.52 | 20 | 12.36 | 2944 | 728 | 1.38 / 685.81 | 6 | 52 |
4 | 13 | 2006.44 | 20 | 12.55 | 2909 | 730 | 2.11 / 686.54 | 6 | 59 |
5 | 13 | 1934.64 | 20 | 12.63 | 2822 | 713 | 2.83 / 687.26 | 6 | 63 |
6 | 13 | 1635.08 | 20 | 12.86 | 2467 | 635 | 3.46 / 687.89 | 6 | 74 |
7 | 13 | 1113.60 | 20 | 13.24 | 1811 | 480 | 3.94 / 688.37 | 6 | 86 |
8 | 13 | 560.40 | 20 | 13.70 | 1086 | 298 | 4.24 / 688.67 | 6 | 83 |
9 | 13 | 130.16 | 20 | 14.18 | 492 | 140 | 4.38 / 688.81 | 6 | 75 |
10 | 13 | 34.64 | 20 | 14.36 | 351 | 101 | 4.48 / 688.91 | 6 | 67 |
11 | 8 | 0.08 | 246 | 14.33 | 306 | 1079 | 5.56 / 689.99 | 7 | 130 |
Average= | 5.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.16 | 32 | 14.39 | 435 | 200 | 0.20 / 678.97 | 7 | 9 |
2 | 7 | 2001.68 | 40 | 5.50 | 2431 | 535 | 0.74 / 679.51 | 9 | 7 |
3 | 13 | 2050.00 | 20 | 12.31 | 2954 | 727 | 1.46 / 680.24 | 6 | 52 |
4 | 13 | 1999.28 | 20 | 12.54 | 2892 | 725 | 2.19 / 680.96 | 6 | 59 |
5 | 13 | 1918.40 | 20 | 12.61 | 2814 | 710 | 2.90 / 681.67 | 6 | 65 |
6 | 13 | 1825.88 | 20 | 12.70 | 2708 | 688 | 3.59 / 682.36 | 6 | 70 |
7 | 13 | 1060.28 | 20 | 13.26 | 1734 | 460 | 4.05 / 682.82 | 6 | 84 |
8 | 13 | 513.72 | 20 | 13.74 | 1031 | 283 | 4.33 / 683.10 | 6 | 82 |
9 | 13 | 98.80 | 20 | 14.23 | 456 | 130 | 4.46 / 683.23 | 6 | 76 |
10 | 13 | 50.52 | 20 | 14.31 | 385 | 110 | 4.57 / 683.34 | 6 | 72 |
11 | 8 | 0.28 | 246 | 14.30 | 309 | 1087 | 5.66 / 684.43 | 6 | 137 |
Average= | 5.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.16 | 32 | 14.38 | 417 | 192 | 0.19 / 673.34 | 7 | 9 |
2 | 7 | 2001.12 | 41 | 6.23 | 2506 | 640 | 0.83 / 673.98 | 9 | 11 |
3 | 13 | 2040.96 | 20 | 12.32 | 2932 | 722 | 1.55 / 674.71 | 6 | 53 |
4 | 13 | 1987.44 | 20 | 12.47 | 2909 | 726 | 2.28 / 675.43 | 6 | 58 |
5 | 13 | 1897.96 | 20 | 12.62 | 2793 | 705 | 2.98 / 676.14 | 6 | 66 |
6 | 13 | 1692.12 | 20 | 12.78 | 2537 | 648 | 3.63 / 676.79 | 6 | 75 |
7 | 13 | 1031.36 | 20 | 13.30 | 1652 | 439 | 4.07 / 677.22 | 6 | 81 |
8 | 13 | 361.88 | 20 | 13.88 | 830 | 230 | 4.30 / 677.46 | 6 | 82 |
9 | 13 | 89.80 | 20 | 14.22 | 449 | 128 | 4.43 / 677.58 | 6 | 73 |
10 | 13 | 47.36 | 20 | 14.31 | 388 | 111 | 4.54 / 677.69 | 6 | 69 |
11 | 8 | 0.56 | 242 | 14.31 | 312 | 1080 | 5.62 / 678.77 | 7 | 132 |
Average= | 5.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.40 | 32 | 14.40 | 432 | 199 | 0.20 / 667.97 | 7 | 8 |
2 | 7 | 2001.28 | 41 | 6.96 | 2492 | 711 | 0.91 / 668.68 | 8 | 16 |
3 | 13 | 2007.68 | 20 | 12.30 | 2893 | 712 | 1.62 / 669.39 | 6 | 54 |
4 | 13 | 1942.16 | 20 | 12.51 | 2831 | 708 | 2.33 / 670.10 | 6 | 59 |
5 | 13 | 1853.08 | 20 | 12.61 | 2748 | 693 | 3.02 / 670.79 | 6 | 67 |
6 | 13 | 1429.92 | 20 | 12.97 | 2200 | 571 | 3.59 / 671.36 | 6 | 77 |
7 | 13 | 788.56 | 20 | 13.48 | 1345 | 363 | 3.96 / 671.72 | 6 | 74 |
8 | 13 | 248.96 | 20 | 14.00 | 669 | 187 | 4.14 / 671.91 | 6 | 74 |
9 | 13 | 77.32 | 20 | 14.26 | 419 | 119 | 4.26 / 672.03 | 6 | 74 |
10 | 13 | 21.16 | 20 | 14.36 | 339 | 97 | 4.36 / 672.13 | 6 | 69 |
11 | 8 | 0.12 | 239 | 14.34 | 299 | 1025 | 5.39 / 673.15 | 7 | 130 |
Average= | 5.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.48 | 32 | 14.39 | 429 | 198 | 0.20 / 662.63 | 7 | 8 |
2 | 7 | 2010.76 | 41 | 7.27 | 2559 | 763 | 0.96 / 663.39 | 8 | 19 |
3 | 13 | 1996.64 | 20 | 12.30 | 2906 | 715 | 1.68 / 664.11 | 6 | 56 |
4 | 13 | 1931.20 | 20 | 12.48 | 2815 | 703 | 2.38 / 664.81 | 6 | 60 |
5 | 13 | 1842.08 | 20 | 12.62 | 2710 | 684 | 3.06 / 665.50 | 6 | 67 |
6 | 13 | 1317.20 | 20 | 13.05 | 2031 | 530 | 3.59 / 666.03 | 6 | 76 |
7 | 13 | 668.04 | 20 | 13.59 | 1207 | 328 | 3.92 / 666.35 | 6 | 73 |
8 | 13 | 219.32 | 20 | 14.03 | 630 | 177 | 4.10 / 666.53 | 6 | 78 |
9 | 13 | 65.04 | 20 | 14.29 | 405 | 116 | 4.21 / 666.65 | 6 | 74 |
10 | 13 | 36.20 | 20 | 14.34 | 360 | 103 | 4.32 / 666.75 | 6 | 71 |
11 | 8 | 0.04 | 235 | 14.32 | 302 | 1016 | 5.33 / 667.77 | 7 | 132 |
Average= | 5.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.80 | 32 | 14.41 | 420 | 194 | 0.19 / 657.29 | 7 | 9 |
2 | 7 | 2011.64 | 40 | 7.63 | 2604 | 795 | 0.99 / 658.09 | 9 | 21 |
3 | 13 | 1991.64 | 20 | 12.35 | 2874 | 710 | 1.70 / 658.80 | 6 | 54 |
4 | 13 | 1930.64 | 20 | 12.50 | 2796 | 699 | 2.40 / 659.50 | 6 | 59 |
5 | 13 | 1838.84 | 20 | 12.60 | 2712 | 683 | 3.08 / 660.18 | 6 | 67 |
6 | 13 | 1370.08 | 20 | 13.01 | 2109 | 549 | 3.63 / 660.73 | 6 | 78 |
7 | 13 | 692.68 | 20 | 13.56 | 1230 | 334 | 3.96 / 661.06 | 6 | 72 |
8 | 13 | 162.32 | 20 | 14.13 | 552 | 156 | 4.12 / 661.22 | 6 | 76 |
9 | 13 | 84.24 | 20 | 14.25 | 435 | 124 | 4.24 / 661.34 | 6 | 75 |
10 | 13 | 21.88 | 20 | 14.37 | 337 | 97 | 4.34 / 661.44 | 7 | 69 |
11 | 8 | 0.12 | 232 | 14.33 | 299 | 994 | 5.33 / 662.43 | 7 | 129 |
Average= | 5.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.36 | 32 | 14.39 | 417 | 192 | 0.19 / 652.04 | 7 | 10 |
2 | 7 | 2003.32 | 40 | 7.58 | 2610 | 791 | 0.98 / 652.84 | 10 | 22 |
3 | 13 | 1976.16 | 20 | 12.31 | 2854 | 703 | 1.69 / 653.54 | 6 | 54 |
4 | 13 | 1902.80 | 20 | 12.48 | 2787 | 696 | 2.38 / 654.23 | 6 | 57 |
5 | 13 | 1805.64 | 20 | 12.60 | 2677 | 675 | 3.06 / 654.91 | 6 | 67 |
6 | 13 | 1256.72 | 20 | 13.06 | 1980 | 517 | 3.57 / 655.43 | 6 | 82 |
7 | 13 | 607.84 | 20 | 13.64 | 1134 | 309 | 3.88 / 655.73 | 6 | 79 |
8 | 13 | 168.64 | 20 | 14.11 | 554 | 156 | 4.04 / 655.89 | 6 | 78 |
9 | 13 | 49.72 | 20 | 14.34 | 375 | 108 | 4.15 / 656.00 | 6 | 70 |
10 | 13 | 25.40 | 20 | 14.36 | 343 | 99 | 4.25 / 656.10 | 6 | 70 |
11 | 8 | 0.12 | 232 | 14.32 | 302 | 1003 | 5.25 / 657.10 | 7 | 132 |
Average= | 5.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.92 | 32 | 14.37 | 449 | 206 | 0.21 / 646.84 | 7 | 10 |
2 | 7 | 2004.28 | 40 | 7.88 | 2664 | 840 | 1.05 / 647.68 | 10 | 22 |
3 | 13 | 1971.68 | 20 | 12.31 | 2858 | 704 | 1.75 / 648.38 | 6 | 53 |
4 | 13 | 1889.72 | 20 | 12.50 | 2766 | 691 | 2.44 / 649.08 | 6 | 60 |
5 | 13 | 1694.28 | 20 | 12.73 | 2517 | 641 | 3.08 / 649.72 | 6 | 69 |
6 | 13 | 1135.40 | 20 | 13.18 | 1812 | 478 | 3.56 / 650.19 | 6 | 78 |
7 | 13 | 702.36 | 20 | 13.53 | 1264 | 342 | 3.90 / 650.54 | 6 | 81 |
8 | 13 | 144.08 | 20 | 14.15 | 523 | 148 | 4.05 / 650.68 | 6 | 78 |
9 | 13 | 37.76 | 20 | 14.36 | 358 | 103 | 4.15 / 650.79 | 6 | 70 |
10 | 13 | 18.96 | 20 | 14.34 | 332 | 95 | 4.25 / 650.88 | 6 | 71 |
11 | 8 | 0.08 | 228 | 14.33 | 297 | 970 | 5.22 / 651.85 | 7 | 136 |
Average= | 5.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.84 | 32 | 14.36 | 440 | 202 | 0.20 / 641.64 | 7 | 10 |
2 | 7 | 2001.08 | 40 | 8.18 | 2652 | 868 | 1.07 / 642.51 | 10 | 25 |
3 | 13 | 1956.32 | 20 | 12.30 | 2853 | 702 | 1.77 / 643.21 | 6 | 54 |
4 | 13 | 1879.28 | 20 | 12.51 | 2771 | 693 | 2.47 / 643.90 | 6 | 60 |
5 | 13 | 1781.60 | 20 | 12.62 | 2650 | 669 | 3.13 / 644.57 | 6 | 67 |
6 | 13 | 1050.36 | 20 | 13.22 | 1730 | 457 | 3.59 / 645.03 | 6 | 81 |
7 | 13 | 505.80 | 20 | 13.72 | 1023 | 281 | 3.87 / 645.31 | 6 | 80 |
8 | 13 | 171.36 | 20 | 14.10 | 566 | 160 | 4.03 / 645.47 | 6 | 80 |
9 | 13 | 25.16 | 20 | 14.36 | 345 | 99 | 4.13 / 645.57 | 6 | 69 |
10 | 13 | 12.92 | 20 | 14.34 | 330 | 95 | 4.23 / 645.67 | 7 | 69 |
11 | 8 | 0.08 | 225 | 14.30 | 301 | 968 | 5.19 / 646.63 | 7 | 130 |
Average= | 5.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.72 | 32 | 14.41 | 445 | 205 | 0.21 / 636.40 | 7 | 11 |
2 | 7 | 2002.68 | 40 | 8.31 | 2697 | 896 | 1.10 / 637.30 | 11 | 26 |
3 | 13 | 1958.96 | 20 | 12.34 | 2830 | 698 | 1.80 / 638.00 | 6 | 53 |
4 | 13 | 1881.20 | 20 | 12.53 | 2744 | 688 | 2.49 / 638.69 | 6 | 62 |
5 | 13 | 1782.48 | 20 | 12.63 | 2632 | 665 | 3.15 / 639.35 | 6 | 66 |
6 | 13 | 1023.16 | 20 | 13.26 | 1686 | 447 | 3.60 / 639.80 | 6 | 79 |
7 | 13 | 689.76 | 20 | 13.56 | 1246 | 338 | 3.94 / 640.14 | 6 | 79 |
8 | 13 | 115.84 | 20 | 14.20 | 477 | 135 | 4.07 / 640.27 | 6 | 77 |
9 | 13 | 33.44 | 20 | 14.34 | 356 | 102 | 4.18 / 640.37 | 6 | 71 |
10 | 8 | 0.12 | 246 | 14.29 | 303 | 1065 | 5.24 / 641.44 | 7 | 134 |
Average= | 5.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.08 | 32 | 14.38 | 424 | 195 | 0.20 / 631.37 | 7 | 12 |
2 | 7 | 2009.36 | 40 | 8.53 | 2721 | 928 | 1.12 / 632.30 | 6 | 26 |
3 | 13 | 1966.92 | 20 | 12.32 | 2846 | 701 | 1.82 / 633.00 | 6 | 54 |
4 | 13 | 1890.60 | 20 | 12.51 | 2762 | 691 | 2.52 / 633.69 | 6 | 58 |
5 | 13 | 1500.44 | 20 | 12.86 | 2278 | 586 | 3.10 / 634.28 | 6 | 74 |
6 | 13 | 1067.16 | 20 | 13.22 | 1736 | 459 | 3.56 / 634.74 | 6 | 80 |
7 | 13 | 320.88 | 20 | 13.93 | 758 | 211 | 3.77 / 634.95 | 6 | 79 |
8 | 13 | 61.80 | 20 | 14.30 | 394 | 113 | 3.88 / 635.06 | 6 | 71 |
9 | 13 | 2.00 | 20 | 14.40 | 310 | 89 | 3.97 / 635.15 | 6 | 68 |
10 | 8 | 0.08 | 242 | 14.29 | 303 | 1048 | 5.02 / 636.20 | 7 | 130 |
Average= | 5.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.56 | 32 | 14.39 | 426 | 196 | 0.20 / 626.33 | 7 | 13 |
2 | 7 | 2002.52 | 40 | 8.70 | 2711 | 943 | 1.14 / 627.27 | 13 | 27 |
3 | 13 | 1956.72 | 20 | 12.34 | 2822 | 696 | 1.84 / 627.97 | 6 | 52 |
4 | 13 | 1871.56 | 20 | 12.51 | 2723 | 681 | 2.52 / 628.65 | 6 | 58 |
5 | 13 | 1670.52 | 20 | 12.71 | 2502 | 636 | 3.15 / 629.28 | 6 | 68 |
6 | 13 | 922.32 | 20 | 13.34 | 1556 | 415 | 3.57 / 629.70 | 6 | 80 |
7 | 13 | 388.60 | 20 | 13.85 | 858 | 238 | 3.81 / 629.94 | 6 | 82 |
8 | 13 | 81.96 | 20 | 14.26 | 427 | 122 | 3.93 / 630.06 | 6 | 75 |
9 | 8 | 0.08 | 258 | 14.27 | 304 | 1119 | 5.05 / 631.18 | 6 | 129 |
Average= | 5.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.64 | 32 | 14.37 | 433 | 199 | 0.20 / 621.21 | 7 | 13 |
2 | 7 | 2007.16 | 41 | 8.77 | 2752 | 990 | 1.19 / 622.20 | 13 | 28 |
3 | 13 | 1966.72 | 20 | 12.32 | 2840 | 700 | 1.89 / 622.90 | 6 | 52 |
4 | 13 | 1882.04 | 20 | 12.51 | 2746 | 687 | 2.58 / 623.59 | 6 | 60 |
5 | 13 | 1569.76 | 20 | 12.80 | 2369 | 606 | 3.18 / 624.19 | 6 | 72 |
6 | 13 | 942.96 | 20 | 13.32 | 1586 | 423 | 3.60 / 624.62 | 6 | 82 |
7 | 13 | 418.92 | 20 | 13.83 | 897 | 248 | 3.85 / 624.86 | 6 | 79 |
8 | 13 | 95.56 | 20 | 14.22 | 459 | 131 | 3.98 / 624.99 | 6 | 77 |
9 | 8 | 0.12 | 258 | 14.26 | 309 | 1137 | 5.12 / 626.13 | 6 | 132 |
Average= | 5.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.68 | 32 | 14.36 | 433 | 199 | 0.20 / 616.17 | 7 | 14 |
2 | 7 | 2009.20 | 40 | 9.04 | 2738 | 990 | 1.19 / 617.16 | 14 | 30 |
3 | 13 | 1952.52 | 20 | 12.31 | 2841 | 699 | 1.89 / 617.86 | 6 | 52 |
4 | 13 | 1864.52 | 20 | 12.51 | 2722 | 681 | 2.57 / 618.54 | 6 | 59 |
5 | 13 | 1455.84 | 20 | 12.88 | 2250 | 580 | 3.15 / 619.12 | 6 | 72 |
6 | 13 | 1035.68 | 20 | 13.25 | 1704 | 452 | 3.60 / 619.57 | 6 | 82 |
7 | 13 | 278.44 | 20 | 13.95 | 713 | 199 | 3.80 / 619.77 | 6 | 78 |
8 | 13 | 93.88 | 20 | 14.22 | 449 | 128 | 3.93 / 619.90 | 6 | 77 |
9 | 8 | 0.08 | 258 | 14.27 | 302 | 1112 | 5.04 / 621.01 | 6 | 129 |
Average= | 5.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.56 | 32 | 14.37 | 436 | 200 | 0.20 / 611.09 | 7 | 13 |
2 | 7 | 2005.76 | 40 | 9.16 | 2744 | 1005 | 1.21 / 612.10 | 13 | 30 |
3 | 13 | 1961.60 | 20 | 12.34 | 2831 | 699 | 1.90 / 612.80 | 6 | 53 |
4 | 13 | 1876.28 | 20 | 12.52 | 2750 | 689 | 2.59 / 613.49 | 6 | 61 |
5 | 13 | 1562.32 | 20 | 12.80 | 2377 | 609 | 3.20 / 614.09 | 6 | 71 |
6 | 13 | 925.20 | 20 | 13.33 | 1567 | 418 | 3.62 / 614.51 | 6 | 83 |
7 | 13 | 288.64 | 20 | 13.96 | 726 | 203 | 3.82 / 614.71 | 6 | 78 |
8 | 13 | 45.00 | 20 | 14.30 | 380 | 109 | 3.93 / 614.82 | 6 | 74 |
9 | 8 | 0.40 | 256 | 14.24 | 315 | 1148 | 5.08 / 615.97 | 6 | 130 |
Average= | 5.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.32 | 32 | 14.32 | 435 | 199 | 0.20 / 606.00 | 7 | 12 |
2 | 7 | 2011.24 | 40 | 9.28 | 2773 | 1029 | 1.23 / 607.02 | 12 | 32 |
3 | 13 | 1965.68 | 20 | 12.33 | 2846 | 702 | 1.93 / 607.73 | 6 | 53 |
4 | 13 | 1876.32 | 20 | 12.53 | 2738 | 686 | 2.62 / 608.41 | 6 | 61 |
5 | 13 | 1568.60 | 20 | 12.80 | 2376 | 608 | 3.22 / 609.02 | 6 | 72 |
6 | 13 | 924.80 | 20 | 13.33 | 1559 | 416 | 3.64 / 609.44 | 6 | 80 |
7 | 13 | 282.00 | 20 | 13.96 | 714 | 199 | 3.84 / 609.64 | 6 | 82 |
8 | 13 | 85.32 | 20 | 14.24 | 441 | 126 | 3.97 / 609.76 | 6 | 76 |
9 | 8 | 0.00 | 256 | 14.25 | 310 | 1131 | 5.10 / 610.89 | 6 | 131 |
Average= | 5.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.44 | 32 | 14.32 | 455 | 208 | 0.21 / 600.91 | 7 | 14 |
2 | 7 | 2004.44 | 41 | 9.34 | 2773 | 1062 | 1.27 / 601.97 | 6 | 32 |
3 | 13 | 1952.32 | 20 | 12.34 | 2827 | 698 | 1.97 / 602.67 | 6 | 55 |
4 | 13 | 1864.32 | 20 | 12.51 | 2726 | 682 | 2.65 / 603.35 | 6 | 62 |
5 | 13 | 1353.16 | 20 | 12.98 | 2094 | 544 | 3.19 / 603.90 | 6 | 78 |
6 | 13 | 1040.76 | 20 | 13.23 | 1706 | 451 | 3.65 / 604.35 | 6 | 81 |
7 | 13 | 254.32 | 20 | 14.00 | 676 | 189 | 3.83 / 604.54 | 6 | 78 |
8 | 13 | 68.20 | 20 | 14.27 | 411 | 117 | 3.95 / 604.66 | 6 | 76 |
9 | 13 | 41.68 | 20 | 14.29 | 371 | 106 | 4.06 / 604.76 | 6 | 76 |
10 | 8 | 0.00 | 237 | 14.26 | 306 | 1034 | 5.09 / 605.80 | 6 | 131 |
Average= | 5.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.48 | 32 | 14.39 | 431 | 198 | 0.20 / 595.77 | 7 | 13 |
2 | 7 | 2011.44 | 40 | 9.46 | 2772 | 1049 | 1.25 / 596.82 | 13 | 32 |
3 | 13 | 1955.04 | 20 | 12.34 | 2840 | 701 | 1.95 / 597.52 | 6 | 55 |
4 | 13 | 1861.96 | 20 | 12.52 | 2745 | 687 | 2.64 / 598.21 | 6 | 62 |
5 | 13 | 1356.16 | 20 | 12.99 | 2095 | 544 | 3.18 / 598.76 | 6 | 78 |
6 | 13 | 1043.00 | 20 | 13.23 | 1702 | 450 | 3.63 / 599.21 | 6 | 84 |
7 | 13 | 351.84 | 20 | 13.89 | 803 | 223 | 3.85 / 599.43 | 6 | 81 |
8 | 13 | 65.80 | 20 | 14.26 | 411 | 117 | 3.97 / 599.55 | 6 | 77 |
9 | 8 | 0.04 | 259 | 14.24 | 314 | 1158 | 5.13 / 600.70 | 6 | 130 |
Average= | 5.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.28 | 32 | 14.39 | 428 | 197 | 0.20 / 590.65 | 7 | 12 |
2 | 7 | 2008.28 | 41 | 9.49 | 2796 | 1088 | 1.28 / 591.74 | 12 | 35 |
3 | 13 | 1951.68 | 20 | 12.36 | 2819 | 697 | 1.98 / 592.44 | 6 | 56 |
4 | 13 | 1860.16 | 20 | 12.52 | 2719 | 681 | 2.66 / 593.12 | 6 | 61 |
5 | 13 | 1356.32 | 20 | 12.96 | 2123 | 550 | 3.21 / 593.67 | 6 | 79 |
6 | 13 | 1036.16 | 20 | 13.23 | 1710 | 452 | 3.67 / 594.12 | 6 | 83 |
7 | 13 | 257.76 | 20 | 13.99 | 680 | 190 | 3.86 / 594.31 | 6 | 81 |
8 | 13 | 79.92 | 20 | 14.23 | 430 | 122 | 3.98 / 594.44 | 6 | 76 |
9 | 8 | 0.12 | 258 | 14.25 | 310 | 1140 | 5.12 / 595.58 | 6 | 135 |
Average= | 5.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.60 | 32 | 14.35 | 435 | 200 | 0.20 / 585.56 | 7 | 12 |
2 | 7 | 2010.68 | 40 | 9.55 | 2775 | 1060 | 1.26 / 586.62 | 12 | 33 |
3 | 13 | 1952.72 | 20 | 12.33 | 2825 | 697 | 1.96 / 587.32 | 6 | 55 |
4 | 13 | 1859.00 | 20 | 12.52 | 2742 | 687 | 2.64 / 588.01 | 6 | 63 |
5 | 13 | 1537.64 | 20 | 12.84 | 2325 | 597 | 3.24 / 588.60 | 6 | 74 |
6 | 13 | 977.52 | 20 | 13.27 | 1630 | 433 | 3.67 / 589.04 | 6 | 84 |
7 | 13 | 214.60 | 20 | 14.02 | 624 | 175 | 3.85 / 589.21 | 6 | 79 |
8 | 13 | 58.72 | 20 | 14.29 | 393 | 112 | 3.96 / 589.32 | 6 | 74 |
9 | 8 | 0.08 | 259 | 14.26 | 307 | 1134 | 5.09 / 590.46 | 7 | 129 |
Average= | 5.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.08 | 32 | 14.36 | 441 | 203 | 0.20 / 580.47 | 7 | 11 |
2 | 7 | 2004.68 | 40 | 9.73 | 2784 | 1084 | 1.29 / 581.55 | 6 | 34 |
3 | 13 | 1951.08 | 20 | 12.34 | 2844 | 702 | 1.99 / 582.25 | 6 | 56 |
4 | 13 | 1870.88 | 20 | 12.54 | 2745 | 688 | 2.68 / 582.94 | 6 | 61 |
5 | 13 | 1368.04 | 20 | 12.95 | 2140 | 554 | 3.23 / 583.50 | 6 | 78 |
6 | 13 | 946.24 | 20 | 13.32 | 1593 | 424 | 3.66 / 583.92 | 6 | 80 |
7 | 13 | 274.12 | 20 | 13.97 | 707 | 198 | 3.85 / 584.12 | 6 | 82 |
8 | 13 | 80.80 | 20 | 14.24 | 425 | 121 | 3.97 / 584.24 | 6 | 77 |
9 | 8 | 0.08 | 256 | 14.25 | 308 | 1124 | 5.10 / 585.36 | 6 | 134 |
Average= | 5.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.00 | 32 | 14.37 | 429 | 197 | 0.20 / 575.27 | 7 | 11 |
2 | 7 | 2001.12 | 40 | 9.70 | 2792 | 1083 | 1.28 / 576.36 | 11 | 35 |
3 | 13 | 1933.00 | 20 | 12.38 | 2783 | 689 | 1.97 / 577.05 | 6 | 56 |
4 | 13 | 1847.36 | 20 | 12.52 | 2706 | 678 | 2.65 / 577.72 | 6 | 63 |
5 | 13 | 1432.28 | 20 | 12.92 | 2199 | 568 | 3.22 / 578.29 | 6 | 77 |
6 | 13 | 1113.84 | 20 | 13.17 | 1807 | 476 | 3.69 / 578.77 | 6 | 82 |
7 | 13 | 406.32 | 20 | 13.83 | 876 | 242 | 3.93 / 579.01 | 6 | 83 |
8 | 13 | 86.60 | 20 | 14.24 | 432 | 123 | 4.06 / 579.13 | 6 | 76 |
9 | 8 | 0.08 | 259 | 14.26 | 307 | 1134 | 5.19 / 580.27 | 6 | 135 |
Average= | 5.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.24 | 32 | 14.36 | 441 | 203 | 0.20 / 570.16 | 7 | 11 |
2 | 7 | 2006.92 | 41 | 9.74 | 2787 | 1113 | 1.32 / 571.27 | 6 | 35 |
3 | 13 | 1965.28 | 20 | 12.33 | 2846 | 702 | 2.02 / 571.97 | 6 | 56 |
4 | 13 | 1884.52 | 20 | 12.50 | 2758 | 689 | 2.71 / 572.66 | 6 | 63 |
5 | 13 | 1465.36 | 20 | 12.89 | 2242 | 578 | 3.28 / 573.24 | 6 | 79 |
6 | 13 | 840.60 | 20 | 13.40 | 1447 | 388 | 3.67 / 573.63 | 6 | 83 |
7 | 13 | 296.76 | 20 | 13.96 | 737 | 206 | 3.88 / 573.83 | 6 | 82 |
8 | 13 | 49.44 | 20 | 14.32 | 383 | 110 | 3.99 / 573.94 | 6 | 73 |
9 | 8 | 0.08 | 258 | 14.26 | 308 | 1133 | 5.12 / 575.08 | 7 | 140 |
Average= | 5.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.08 | 32 | 14.37 | 428 | 197 | 0.20 / 565.02 | 7 | 10 |
2 | 7 | 2003.04 | 40 | 9.78 | 2785 | 1089 | 1.29 / 566.11 | 6 | 35 |
3 | 13 | 1948.12 | 20 | 12.35 | 2825 | 698 | 1.98 / 566.81 | 6 | 56 |
4 | 13 | 1865.56 | 20 | 12.53 | 2733 | 685 | 2.67 / 567.50 | 6 | 65 |
5 | 13 | 1444.60 | 20 | 12.89 | 2232 | 575 | 3.24 / 568.07 | 6 | 78 |
6 | 13 | 1018.20 | 20 | 13.25 | 1680 | 445 | 3.69 / 568.52 | 6 | 86 |
7 | 13 | 241.16 | 20 | 14.01 | 657 | 184 | 3.87 / 568.70 | 6 | 82 |
8 | 13 | 66.72 | 20 | 14.29 | 402 | 115 | 3.99 / 568.82 | 6 | 75 |
9 | 8 | 0.04 | 261 | 14.26 | 306 | 1139 | 5.13 / 569.95 | 6 | 140 |
Average= | 5.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.28 | 32 | 14.43 | 426 | 197 | 0.20 / 559.85 | 7 | 11 |
2 | 7 | 2004.60 | 40 | 9.75 | 2774 | 1082 | 1.28 / 560.93 | 11 | 36 |
3 | 13 | 1953.64 | 20 | 12.33 | 2829 | 698 | 1.98 / 561.63 | 6 | 56 |
4 | 13 | 1881.48 | 20 | 12.50 | 2766 | 691 | 2.67 / 562.32 | 6 | 62 |
5 | 13 | 1473.48 | 20 | 12.88 | 2247 | 579 | 3.25 / 562.90 | 6 | 78 |
6 | 13 | 1030.56 | 20 | 13.25 | 1696 | 449 | 3.70 / 563.35 | 6 | 86 |
7 | 13 | 371.72 | 20 | 13.87 | 833 | 231 | 3.93 / 563.58 | 6 | 85 |
8 | 13 | 76.92 | 20 | 14.26 | 418 | 119 | 4.05 / 563.70 | 6 | 77 |
9 | 8 | 0.08 | 258 | 14.26 | 307 | 1129 | 5.18 / 564.83 | 6 | 132 |
Average= | 5.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.16 | 32 | 14.42 | 415 | 191 | 0.19 / 554.71 | 7 | 11 |
2 | 7 | 2005.80 | 40 | 9.85 | 2797 | 1102 | 1.29 / 555.81 | 11 | 37 |
3 | 13 | 1937.60 | 20 | 12.37 | 2797 | 692 | 1.99 / 556.50 | 6 | 56 |
4 | 13 | 1753.24 | 20 | 12.64 | 2610 | 660 | 2.65 / 557.16 | 6 | 67 |
5 | 13 | 1654.88 | 20 | 12.71 | 2490 | 633 | 3.28 / 557.79 | 6 | 71 |
6 | 13 | 889.56 | 20 | 13.38 | 1505 | 403 | 3.68 / 558.20 | 6 | 82 |
7 | 13 | 342.04 | 20 | 13.90 | 790 | 220 | 3.90 / 558.42 | 6 | 83 |
8 | 13 | 59.80 | 20 | 14.29 | 396 | 113 | 4.01 / 558.53 | 6 | 75 |
9 | 8 | 0.08 | 258 | 14.26 | 305 | 1122 | 5.14 / 559.65 | 6 | 132 |
Average= | 5.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.36 | 32 | 14.37 | 435 | 200 | 0.20 / 549.60 | 7 | 12 |
2 | 7 | 2003.68 | 41 | 9.89 | 2781 | 1128 | 1.33 / 550.72 | 12 | 36 |
3 | 13 | 1947.12 | 20 | 12.34 | 2824 | 697 | 2.02 / 551.42 | 6 | 56 |
4 | 13 | 1860.84 | 20 | 12.51 | 2747 | 687 | 2.71 / 552.11 | 6 | 64 |
5 | 13 | 1544.36 | 20 | 12.83 | 2347 | 602 | 3.31 / 552.71 | 6 | 75 |
6 | 13 | 869.56 | 20 | 13.37 | 1491 | 399 | 3.71 / 553.11 | 6 | 84 |
7 | 13 | 229.08 | 20 | 14.03 | 644 | 181 | 3.89 / 553.29 | 6 | 82 |
8 | 13 | 65.40 | 20 | 14.29 | 402 | 115 | 4.01 / 553.41 | 6 | 75 |
9 | 8 | 0.08 | 256 | 14.26 | 304 | 1110 | 5.12 / 554.52 | 6 | 134 |
Average= | 5.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.16 | 32 | 14.41 | 425 | 196 | 0.20 / 544.49 | 7 | 11 |
2 | 7 | 2009.40 | 41 | 9.88 | 2781 | 1127 | 1.32 / 545.62 | 11 | 35 |
3 | 13 | 1943.68 | 20 | 12.33 | 2810 | 693 | 2.02 / 546.31 | 6 | 57 |
4 | 13 | 1846.96 | 20 | 12.52 | 2727 | 683 | 2.70 / 546.99 | 6 | 63 |
5 | 13 | 1431.24 | 20 | 12.90 | 2216 | 572 | 3.27 / 547.56 | 6 | 78 |
6 | 13 | 885.84 | 20 | 13.38 | 1490 | 399 | 3.67 / 547.96 | 6 | 79 |
7 | 13 | 322.60 | 20 | 13.92 | 762 | 212 | 3.88 / 548.17 | 6 | 82 |
8 | 13 | 52.64 | 20 | 14.30 | 386 | 110 | 3.99 / 548.29 | 6 | 74 |
9 | 8 | 0.00 | 258 | 14.27 | 302 | 1112 | 5.10 / 549.40 | 6 | 139 |
Average= | 4.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.72 | 32 | 14.41 | 430 | 198 | 0.20 / 539.44 | 7 | 10 |
2 | 7 | 2003.32 | 40 | 9.92 | 2781 | 1104 | 1.30 / 540.55 | 6 | 37 |
3 | 13 | 1946.08 | 20 | 12.34 | 2818 | 695 | 2.00 / 541.24 | 6 | 56 |
4 | 13 | 1857.60 | 20 | 12.53 | 2713 | 680 | 2.68 / 541.92 | 6 | 64 |
5 | 13 | 1452.16 | 20 | 12.92 | 2202 | 569 | 3.25 / 542.49 | 6 | 76 |
6 | 13 | 909.56 | 20 | 13.36 | 1527 | 408 | 3.65 / 542.90 | 6 | 84 |
7 | 13 | 253.84 | 20 | 14.01 | 659 | 185 | 3.84 / 543.08 | 6 | 79 |
8 | 13 | 77.88 | 20 | 14.28 | 409 | 117 | 3.96 / 543.20 | 6 | 74 |
9 | 8 | 0.12 | 258 | 14.27 | 297 | 1093 | 5.05 / 544.29 | 6 | 133 |
Average= | 4.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.08 | 32 | 14.40 | 432 | 199 | 0.20 / 534.38 | 7 | 11 |
2 | 7 | 2004.20 | 40 | 9.93 | 2775 | 1102 | 1.30 / 535.48 | 11 | 36 |
3 | 13 | 1942.16 | 20 | 12.33 | 2820 | 695 | 2.00 / 536.18 | 6 | 55 |
4 | 13 | 1852.08 | 20 | 12.55 | 2704 | 679 | 2.68 / 536.86 | 6 | 63 |
5 | 13 | 1427.16 | 20 | 12.93 | 2193 | 567 | 3.24 / 537.42 | 6 | 76 |
6 | 13 | 892.56 | 20 | 13.37 | 1518 | 406 | 3.65 / 537.83 | 6 | 82 |
7 | 13 | 251.08 | 20 | 14.01 | 666 | 187 | 3.84 / 538.02 | 6 | 81 |
8 | 13 | 74.16 | 20 | 14.30 | 405 | 116 | 3.95 / 538.13 | 6 | 74 |
9 | 8 | 0.12 | 258 | 14.27 | 302 | 1112 | 5.06 / 539.24 | 6 | 138 |
Average= | 4.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.08 | 32 | 14.44 | 417 | 193 | 0.19 / 529.28 | 7 | 12 |
2 | 7 | 2007.72 | 41 | 10.00 | 2805 | 1150 | 1.34 / 530.43 | 12 | 37 |
3 | 13 | 1949.52 | 20 | 12.37 | 2817 | 697 | 2.04 / 531.13 | 6 | 55 |
4 | 13 | 1857.20 | 20 | 12.56 | 2715 | 682 | 2.72 / 531.81 | 6 | 62 |
5 | 13 | 1432.76 | 20 | 12.93 | 2206 | 570 | 3.29 / 532.38 | 6 | 76 |
6 | 13 | 888.72 | 20 | 13.38 | 1504 | 402 | 3.69 / 532.78 | 6 | 83 |
7 | 13 | 242.80 | 20 | 14.03 | 655 | 184 | 3.88 / 532.97 | 6 | 80 |
8 | 13 | 68.44 | 20 | 14.29 | 404 | 115 | 3.99 / 533.08 | 6 | 72 |
9 | 8 | 0.12 | 256 | 14.28 | 301 | 1100 | 5.09 / 534.18 | 7 | 132 |
Average= | 4.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.20 | 32 | 14.41 | 425 | 196 | 0.20 / 524.27 | 7 | 13 |
2 | 7 | 2006.52 | 40 | 10.05 | 2799 | 1125 | 1.32 / 525.39 | 6 | 36 |
3 | 13 | 1937.52 | 20 | 12.32 | 2827 | 697 | 2.02 / 526.09 | 6 | 55 |
4 | 13 | 1750.36 | 20 | 12.65 | 2591 | 656 | 2.67 / 526.75 | 6 | 66 |
5 | 13 | 1656.64 | 20 | 12.73 | 2471 | 629 | 3.30 / 527.37 | 6 | 69 |
6 | 13 | 853.20 | 20 | 13.39 | 1462 | 392 | 3.69 / 527.77 | 6 | 84 |
7 | 13 | 210.60 | 20 | 14.07 | 615 | 173 | 3.87 / 527.94 | 6 | 80 |
8 | 13 | 55.72 | 20 | 14.35 | 369 | 106 | 3.97 / 528.04 | 6 | 71 |
9 | 8 | 0.08 | 256 | 14.30 | 285 | 1043 | 5.02 / 529.09 | 6 | 133 |
Average= | 4.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.72 | 32 | 14.40 | 438 | 202 | 0.20 / 519.26 | 7 | 12 |
2 | 7 | 2007.60 | 41 | 10.07 | 2791 | 1152 | 1.35 / 520.41 | 6 | 35 |
3 | 13 | 1946.60 | 20 | 12.34 | 2837 | 700 | 2.05 / 521.11 | 6 | 54 |
4 | 13 | 1860.00 | 20 | 12.54 | 2724 | 683 | 2.74 / 521.80 | 6 | 63 |
5 | 13 | 1334.68 | 20 | 13.01 | 2084 | 542 | 3.28 / 522.34 | 6 | 79 |
6 | 13 | 802.64 | 20 | 13.46 | 1398 | 376 | 3.66 / 522.72 | 6 | 81 |
7 | 13 | 169.04 | 20 | 14.14 | 550 | 156 | 3.81 / 522.87 | 6 | 74 |
8 | 13 | 87.40 | 20 | 14.26 | 430 | 123 | 3.93 / 522.99 | 6 | 71 |
9 | 8 | 0.12 | 256 | 14.28 | 295 | 1078 | 5.01 / 524.07 | 6 | 131 |
Average= | 4.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.72 | 32 | 14.39 | 440 | 203 | 0.20 / 514.20 | 7 | 12 |
2 | 7 | 2004.64 | 41 | 10.12 | 2793 | 1159 | 1.36 / 515.36 | 12 | 35 |
3 | 13 | 1936.92 | 20 | 12.34 | 2815 | 695 | 2.06 / 516.05 | 6 | 54 |
4 | 13 | 1735.68 | 20 | 12.68 | 2576 | 653 | 2.71 / 516.71 | 6 | 65 |
5 | 13 | 1539.16 | 20 | 12.87 | 2335 | 601 | 3.31 / 517.31 | 6 | 74 |
6 | 13 | 775.96 | 20 | 13.48 | 1370 | 369 | 3.68 / 517.68 | 6 | 80 |
7 | 13 | 230.04 | 20 | 14.05 | 641 | 180 | 3.86 / 517.86 | 6 | 77 |
8 | 13 | 65.04 | 20 | 14.32 | 390 | 112 | 3.97 / 517.97 | 6 | 68 |
9 | 8 | 0.16 | 256 | 14.29 | 298 | 1090 | 5.06 / 519.06 | 7 | 132 |
Average= | 4.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.80 | 32 | 14.39 | 436 | 201 | 0.20 / 509.08 | 7 | 11 |
2 | 7 | 2009.72 | 41 | 10.12 | 2789 | 1157 | 1.36 / 510.24 | 11 | 36 |
3 | 13 | 1948.36 | 20 | 12.36 | 2818 | 697 | 2.05 / 510.94 | 6 | 56 |
4 | 13 | 1860.48 | 20 | 12.55 | 2715 | 681 | 2.74 / 511.62 | 6 | 62 |
5 | 13 | 1554.64 | 20 | 12.84 | 2348 | 603 | 3.34 / 512.22 | 6 | 73 |
6 | 13 | 877.96 | 20 | 13.41 | 1492 | 400 | 3.74 / 512.62 | 6 | 83 |
7 | 13 | 227.24 | 20 | 14.06 | 627 | 176 | 3.92 / 512.80 | 6 | 77 |
8 | 13 | 63.36 | 20 | 14.33 | 386 | 111 | 4.03 / 512.91 | 6 | 69 |
9 | 8 | 0.00 | 256 | 14.29 | 298 | 1090 | 5.12 / 514.00 | 7 | 131 |
Average= | 4.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.60 | 32 | 14.39 | 423 | 195 | 0.19 / 503.73 | 7 | 10 |
2 | 7 | 2007.60 | 40 | 10.17 | 2769 | 1126 | 1.32 / 504.85 | 10 | 36 |
3 | 13 | 1944.08 | 20 | 12.33 | 2829 | 698 | 2.02 / 505.55 | 6 | 53 |
4 | 13 | 1847.04 | 20 | 12.52 | 2723 | 682 | 2.70 / 506.23 | 6 | 62 |
5 | 13 | 1652.64 | 20 | 12.76 | 2484 | 634 | 3.33 / 506.87 | 6 | 71 |
6 | 13 | 1204.24 | 20 | 13.12 | 1921 | 504 | 3.84 / 507.37 | 6 | 79 |
7 | 13 | 510.00 | 20 | 13.75 | 1006 | 277 | 4.12 / 507.65 | 6 | 84 |
8 | 13 | 84.72 | 20 | 14.26 | 423 | 121 | 4.24 / 507.77 | 6 | 72 |
9 | 8 | 0.24 | 261 | 14.27 | 299 | 1114 | 5.35 / 508.88 | 6 | 141 |
Average= | 4.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.44 | 32 | 14.40 | 423 | 195 | 0.19 / 498.71 | 7 | 10 |
2 | 7 | 2002.76 | 40 | 10.21 | 2805 | 1146 | 1.34 / 499.85 | 10 | 37 |
3 | 13 | 1941.92 | 20 | 12.39 | 2799 | 694 | 2.03 / 500.55 | 6 | 55 |
4 | 13 | 1851.28 | 20 | 12.55 | 2715 | 681 | 2.72 / 501.23 | 6 | 64 |
5 | 13 | 1343.08 | 20 | 13.00 | 2089 | 543 | 3.26 / 501.77 | 6 | 78 |
6 | 13 | 812.04 | 20 | 13.46 | 1415 | 381 | 3.64 / 502.15 | 6 | 80 |
7 | 13 | 254.24 | 20 | 14.03 | 669 | 188 | 3.83 / 502.34 | 6 | 78 |
8 | 13 | 77.40 | 20 | 14.28 | 412 | 118 | 3.94 / 502.46 | 6 | 72 |
9 | 13 | 2.68 | 20 | 14.43 | 297 | 86 | 4.03 / 502.54 | 6 | 64 |
10 | 8 | -0.04 | 237 | 14.29 | 292 | 989 | 5.02 / 503.53 | 7 | 133 |
Average= | 4.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.32 | 32 | 14.43 | 432 | 199 | 0.20 / 493.73 | 7 | 10 |
2 | 7 | 2003.24 | 41 | 10.25 | 2781 | 1169 | 1.37 / 494.90 | 6 | 37 |
3 | 13 | 1935.28 | 20 | 12.37 | 2802 | 693 | 2.06 / 495.59 | 6 | 54 |
4 | 13 | 1836.60 | 20 | 12.56 | 2704 | 679 | 2.74 / 496.27 | 6 | 62 |
5 | 13 | 1318.64 | 20 | 13.04 | 2057 | 536 | 3.28 / 496.81 | 6 | 78 |
6 | 13 | 681.56 | 20 | 13.58 | 1247 | 339 | 3.62 / 497.15 | 6 | 80 |
7 | 13 | 160.68 | 20 | 14.14 | 542 | 153 | 3.77 / 497.30 | 6 | 76 |
8 | 13 | 81.88 | 20 | 14.28 | 422 | 121 | 3.89 / 497.42 | 6 | 73 |
9 | 8 | 0.24 | 256 | 14.27 | 299 | 1092 | 4.98 / 498.51 | 7 | 143 |
Average= | 4.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.36 | 32 | 14.40 | 427 | 197 | 0.20 / 488.80 | 7 | 9 |
2 | 7 | 2000.92 | 40 | 10.29 | 2792 | 1149 | 1.35 / 489.95 | 9 | 38 |
3 | 13 | 1923.40 | 20 | 12.41 | 2783 | 691 | 2.04 / 490.64 | 6 | 56 |
4 | 13 | 1830.60 | 20 | 12.60 | 2687 | 677 | 2.71 / 491.32 | 6 | 63 |
5 | 13 | 1218.76 | 20 | 13.11 | 1945 | 510 | 3.22 / 491.83 | 6 | 81 |
6 | 13 | 684.84 | 20 | 13.59 | 1239 | 337 | 3.56 / 492.16 | 6 | 84 |
7 | 13 | 242.36 | 20 | 14.03 | 660 | 185 | 3.75 / 492.35 | 6 | 82 |
8 | 13 | 69.92 | 20 | 14.30 | 408 | 117 | 3.86 / 492.46 | 6 | 73 |
9 | 8 | 0.12 | 254 | 14.27 | 294 | 1066 | 4.93 / 493.53 | 7 | 136 |
Average= | 4.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.44 | 32 | 14.43 | 425 | 196 | 0.20 / 483.68 | 7 | 9 |
2 | 7 | 2012.00 | 40 | 10.26 | 2796 | 1147 | 1.34 / 484.83 | 9 | 39 |
3 | 13 | 1951.72 | 20 | 12.38 | 2831 | 701 | 2.04 / 485.53 | 6 | 56 |
4 | 13 | 1858.44 | 20 | 12.57 | 2733 | 687 | 2.73 / 486.22 | 6 | 64 |
5 | 13 | 1539.52 | 20 | 12.88 | 2332 | 601 | 3.33 / 486.82 | 6 | 76 |
6 | 13 | 769.56 | 20 | 13.50 | 1360 | 367 | 3.70 / 487.18 | 6 | 82 |
7 | 13 | 219.32 | 20 | 14.06 | 629 | 177 | 3.88 / 487.36 | 6 | 82 |
8 | 13 | 63.16 | 20 | 14.29 | 397 | 113 | 3.99 / 487.47 | 6 | 73 |
9 | 13 | 33.36 | 20 | 14.32 | 353 | 101 | 4.09 / 487.58 | 6 | 72 |
10 | 8 | 0.12 | 237 | 14.25 | 304 | 1027 | 5.12 / 488.60 | 7 | 136 |
Average= | 4.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.24 | 32 | 14.39 | 430 | 198 | 0.20 / 478.49 | 7 | 8 |
2 | 7 | 2008.12 | 40 | 10.23 | 2771 | 1134 | 1.33 / 479.62 | 8 | 40 |
3 | 13 | 1946.44 | 20 | 12.38 | 2826 | 700 | 2.03 / 480.32 | 6 | 56 |
4 | 13 | 1857.76 | 20 | 12.57 | 2726 | 685 | 2.72 / 481.01 | 6 | 64 |
5 | 13 | 1457.64 | 20 | 12.96 | 2237 | 580 | 3.30 / 481.59 | 6 | 78 |
6 | 13 | 1133.72 | 20 | 13.22 | 1781 | 471 | 3.77 / 482.06 | 6 | 76 |
7 | 13 | 211.00 | 20 | 14.06 | 613 | 172 | 3.94 / 482.23 | 6 | 80 |
8 | 13 | 66.52 | 20 | 14.30 | 398 | 114 | 4.05 / 482.35 | 6 | 72 |
9 | 13 | 35.04 | 20 | 14.34 | 356 | 102 | 4.16 / 482.45 | 6 | 70 |
10 | 8 | 0.08 | 240 | 14.25 | 303 | 1036 | 5.19 / 483.48 | 7 | 136 |
Average= | 4.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.92 | 32 | 14.42 | 445 | 205 | 0.21 / 473.26 | 7 | 8 |
2 | 7 | 2002.32 | 40 | 10.25 | 2763 | 1133 | 1.34 / 474.40 | 6 | 39 |
3 | 13 | 1933.88 | 20 | 12.41 | 2812 | 698 | 2.04 / 475.09 | 6 | 55 |
4 | 13 | 1841.72 | 20 | 12.59 | 2702 | 680 | 2.72 / 475.77 | 6 | 62 |
5 | 13 | 1743.96 | 20 | 12.72 | 2581 | 657 | 3.37 / 476.43 | 6 | 69 |
6 | 13 | 814.68 | 20 | 13.47 | 1380 | 372 | 3.74 / 476.80 | 6 | 70 |
7 | 13 | 385.24 | 20 | 13.88 | 839 | 233 | 3.98 / 477.04 | 6 | 77 |
8 | 13 | 85.20 | 20 | 14.25 | 435 | 124 | 4.10 / 477.16 | 6 | 76 |
9 | 13 | 27.48 | 20 | 14.36 | 348 | 100 | 4.20 / 477.26 | 6 | 70 |
10 | 8 | 0.12 | 239 | 14.25 | 303 | 1032 | 5.23 / 478.29 | 7 | 129 |
Average= | 4.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.36 | 32 | 14.41 | 438 | 202 | 0.20 / 468.13 | 7 | 9 |
2 | 7 | 2003.92 | 40 | 10.14 | 2784 | 1129 | 1.33 / 469.26 | 9 | 40 |
3 | 13 | 1948.04 | 20 | 12.41 | 2831 | 703 | 2.03 / 469.96 | 6 | 56 |
4 | 13 | 1861.84 | 20 | 12.60 | 2711 | 683 | 2.72 / 470.65 | 6 | 63 |
5 | 13 | 1433.36 | 20 | 12.99 | 2191 | 569 | 3.29 / 471.21 | 6 | 78 |
6 | 13 | 794.24 | 20 | 13.50 | 1364 | 368 | 3.65 / 471.58 | 6 | 70 |
7 | 13 | 348.12 | 20 | 13.92 | 784 | 218 | 3.87 / 471.80 | 6 | 75 |
8 | 13 | 72.80 | 20 | 14.29 | 409 | 117 | 3.99 / 471.92 | 6 | 73 |
9 | 13 | 41.80 | 20 | 14.32 | 363 | 104 | 4.09 / 472.02 | 6 | 70 |
10 | 8 | 0.08 | 242 | 14.27 | 300 | 1036 | 5.13 / 473.06 | 7 | 135 |
Average= | 4.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.04 | 32 | 14.43 | 431 | 199 | 0.20 / 462.95 | 7 | 9 |
2 | 7 | 2007.96 | 40 | 10.14 | 2806 | 1138 | 1.34 / 464.09 | 6 | 39 |
3 | 13 | 1946.20 | 20 | 12.44 | 2813 | 700 | 2.04 / 464.79 | 6 | 57 |
4 | 13 | 1852.16 | 20 | 12.63 | 2693 | 680 | 2.72 / 465.47 | 6 | 63 |
5 | 13 | 1542.16 | 20 | 12.89 | 2338 | 603 | 3.32 / 466.07 | 6 | 76 |
6 | 13 | 781.92 | 20 | 13.50 | 1362 | 368 | 3.69 / 466.44 | 6 | 77 |
7 | 13 | 354.32 | 20 | 13.92 | 804 | 224 | 3.91 / 466.66 | 6 | 79 |
8 | 13 | 72.96 | 20 | 14.28 | 413 | 118 | 4.03 / 466.78 | 6 | 72 |
9 | 13 | 37.52 | 20 | 14.32 | 362 | 104 | 4.13 / 466.89 | 6 | 69 |
10 | 8 | 0.12 | 242 | 14.27 | 302 | 1043 | 5.18 / 467.93 | 7 | 132 |
Average= | 4.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.04 | 32 | 14.43 | 430 | 199 | 0.20 / 457.78 | 7 | 9 |
2 | 7 | 2003.20 | 40 | 10.25 | 2760 | 1132 | 1.33 / 458.92 | 6 | 39 |
3 | 13 | 1942.76 | 20 | 12.40 | 2814 | 698 | 2.03 / 459.61 | 6 | 58 |
4 | 13 | 1856.76 | 20 | 12.61 | 2699 | 681 | 2.71 / 460.29 | 6 | 64 |
5 | 13 | 1436.68 | 20 | 12.96 | 2204 | 571 | 3.28 / 460.86 | 6 | 77 |
6 | 13 | 896.60 | 20 | 13.42 | 1504 | 404 | 3.68 / 461.27 | 6 | 78 |
7 | 13 | 346.88 | 20 | 13.93 | 794 | 221 | 3.90 / 461.49 | 6 | 81 |
8 | 13 | 78.96 | 20 | 14.26 | 424 | 121 | 4.03 / 461.61 | 6 | 73 |
9 | 13 | 20.44 | 20 | 14.37 | 334 | 96 | 4.12 / 461.71 | 6 | 67 |
10 | 13 | 8.12 | 20 | 14.35 | 317 | 91 | 4.21 / 461.80 | 7 | 68 |
11 | 8 | 0.12 | 220 | 14.23 | 305 | 955 | 5.17 / 462.75 | 7 | 132 |
Average= | 4.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.32 | 32 | 14.43 | 419 | 193 | 0.19 / 452.70 | 7 | 9 |
2 | 7 | 2002.88 | 40 | 10.23 | 2754 | 1127 | 1.32 / 453.82 | 9 | 40 |
3 | 13 | 1930.68 | 20 | 12.41 | 2796 | 694 | 2.01 / 454.52 | 6 | 56 |
4 | 13 | 1835.08 | 20 | 12.61 | 2684 | 677 | 2.69 / 455.20 | 6 | 64 |
5 | 13 | 1629.04 | 20 | 12.82 | 2453 | 629 | 3.32 / 455.82 | 6 | 73 |
6 | 13 | 753.32 | 20 | 13.54 | 1318 | 357 | 3.68 / 456.18 | 6 | 77 |
7 | 13 | 230.96 | 20 | 14.06 | 639 | 180 | 3.86 / 456.36 | 6 | 76 |
8 | 13 | 72.68 | 20 | 14.30 | 408 | 117 | 3.97 / 456.48 | 6 | 74 |
9 | 13 | 21.52 | 20 | 14.38 | 331 | 95 | 4.07 / 456.57 | 6 | 69 |
10 | 8 | 0.12 | 239 | 14.26 | 297 | 1012 | 5.08 / 457.58 | 7 | 135 |
Average= | 4.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.84 | 32 | 14.43 | 421 | 194 | 0.19 / 447.60 | 7 | 10 |
2 | 7 | 2008.24 | 40 | 10.12 | 2787 | 1128 | 1.32 / 448.73 | 10 | 39 |
3 | 13 | 1957.76 | 20 | 12.42 | 2823 | 701 | 2.02 / 449.43 | 6 | 57 |
4 | 13 | 1875.08 | 20 | 12.58 | 2755 | 693 | 2.72 / 450.12 | 6 | 65 |
5 | 13 | 1361.40 | 20 | 13.02 | 2120 | 552 | 3.27 / 450.67 | 6 | 79 |
6 | 13 | 919.04 | 20 | 13.42 | 1503 | 403 | 3.67 / 451.08 | 6 | 76 |
7 | 13 | 260.20 | 20 | 14.01 | 683 | 191 | 3.86 / 451.27 | 6 | 81 |
8 | 13 | 80.92 | 20 | 14.26 | 430 | 123 | 3.99 / 451.39 | 6 | 77 |
9 | 13 | 26.00 | 20 | 14.35 | 341 | 98 | 4.08 / 451.49 | 6 | 71 |
10 | 13 | 13.20 | 20 | 14.34 | 323 | 93 | 4.18 / 451.58 | 7 | 71 |
11 | 8 | 0.08 | 218 | 14.23 | 297 | 921 | 5.10 / 452.50 | 7 | 129 |
Average= | 4.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.20 | 32 | 14.45 | 420 | 194 | 0.19 / 442.55 | 7 | 10 |
2 | 7 | 2003.44 | 40 | 10.13 | 2773 | 1124 | 1.32 / 443.68 | 10 | 39 |
3 | 13 | 1944.24 | 20 | 12.42 | 2805 | 697 | 2.01 / 444.37 | 6 | 56 |
4 | 13 | 1847.40 | 20 | 12.61 | 2730 | 689 | 2.70 / 445.06 | 6 | 64 |
5 | 13 | 1324.40 | 20 | 13.06 | 2073 | 541 | 3.24 / 445.60 | 6 | 81 |
6 | 13 | 892.32 | 20 | 13.42 | 1518 | 407 | 3.65 / 446.01 | 6 | 84 |
7 | 13 | 231.96 | 20 | 14.05 | 637 | 179 | 3.83 / 446.19 | 6 | 81 |
8 | 13 | 72.76 | 20 | 14.30 | 407 | 116 | 3.95 / 446.30 | 6 | 74 |
9 | 13 | 5.36 | 20 | 14.41 | 309 | 89 | 4.04 / 446.39 | 6 | 68 |
10 | 8 | 0.16 | 237 | 14.23 | 300 | 1012 | 5.05 / 447.41 | 7 | 131 |
Average= | 4.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.44 | 32 | 14.41 | 436 | 201 | 0.20 / 437.45 | 7 | 10 |
2 | 7 | 2007.16 | 41 | 10.14 | 2762 | 1148 | 1.35 / 438.60 | 6 | 38 |
3 | 13 | 1937.04 | 20 | 12.44 | 2796 | 696 | 2.04 / 439.30 | 6 | 57 |
4 | 13 | 1842.76 | 20 | 12.63 | 2686 | 678 | 2.72 / 439.97 | 6 | 63 |
5 | 13 | 1324.76 | 20 | 13.06 | 2074 | 542 | 3.27 / 440.52 | 6 | 80 |
6 | 13 | 895.28 | 20 | 13.44 | 1511 | 406 | 3.67 / 440.92 | 6 | 82 |
7 | 13 | 338.92 | 20 | 13.93 | 792 | 221 | 3.89 / 441.14 | 6 | 82 |
8 | 13 | 65.28 | 20 | 14.30 | 398 | 114 | 4.01 / 441.26 | 6 | 73 |
9 | 13 | 3.56 | 20 | 14.43 | 308 | 89 | 4.09 / 441.34 | 6 | 69 |
10 | 8 | 0.04 | 237 | 14.24 | 300 | 1012 | 5.11 / 442.36 | 7 | 131 |
Average= | 4.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.52 | 32 | 14.39 | 434 | 200 | 0.20 / 432.31 | 7 | 10 |
2 | 7 | 2009.24 | 41 | 10.14 | 2780 | 1156 | 1.36 / 433.47 | 10 | 39 |
3 | 13 | 1949.00 | 20 | 12.44 | 2824 | 703 | 2.06 / 434.17 | 6 | 55 |
4 | 13 | 1857.60 | 20 | 12.63 | 2736 | 691 | 2.75 / 434.86 | 6 | 62 |
5 | 13 | 1325.00 | 20 | 13.09 | 2060 | 539 | 3.29 / 435.40 | 6 | 77 |
6 | 13 | 890.12 | 20 | 13.44 | 1497 | 402 | 3.69 / 435.80 | 6 | 76 |
7 | 13 | 325.52 | 20 | 13.96 | 772 | 216 | 3.91 / 436.02 | 6 | 82 |
8 | 13 | 55.24 | 20 | 14.32 | 387 | 111 | 4.02 / 436.13 | 6 | 73 |
9 | 13 | 29.52 | 20 | 14.34 | 350 | 100 | 4.12 / 436.23 | 6 | 71 |
10 | 8 | 0.12 | 237 | 14.23 | 303 | 1022 | 5.14 / 437.25 | 6 | 130 |
Average= | 4.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.52 | 32 | 14.46 | 434 | 201 | 0.20 / 427.28 | 7 | 11 |
2 | 7 | 2002.56 | 41 | 10.15 | 2750 | 1144 | 1.35 / 428.42 | 6 | 39 |
3 | 13 | 1937.60 | 20 | 12.47 | 2799 | 698 | 2.04 / 429.12 | 6 | 58 |
4 | 13 | 1847.88 | 20 | 12.66 | 2695 | 682 | 2.73 / 429.80 | 6 | 65 |
5 | 13 | 1435.40 | 20 | 13.01 | 2215 | 576 | 3.30 / 430.38 | 6 | 77 |
6 | 13 | 763.96 | 20 | 13.55 | 1353 | 367 | 3.67 / 430.75 | 6 | 82 |
7 | 13 | 207.72 | 20 | 14.09 | 610 | 172 | 3.84 / 430.92 | 6 | 81 |
8 | 13 | 62.88 | 20 | 14.34 | 395 | 113 | 3.95 / 431.03 | 6 | 72 |
9 | 8 | -0.04 | 256 | 14.25 | 296 | 1080 | 5.03 / 432.11 | 6 | 136 |
Average= | 4.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.16 | 32 | 14.45 | 421 | 195 | 0.19 / 422.10 | 7 | 11 |
2 | 7 | 2004.00 | 40 | 10.06 | 2747 | 1105 | 1.30 / 423.21 | 11 | 39 |
3 | 13 | 1943.24 | 20 | 12.45 | 2808 | 699 | 2.00 / 423.90 | 6 | 55 |
4 | 13 | 1858.12 | 20 | 12.67 | 2716 | 688 | 2.69 / 424.59 | 6 | 62 |
5 | 13 | 1759.76 | 20 | 12.78 | 2603 | 665 | 3.35 / 425.26 | 6 | 70 |
6 | 13 | 852.04 | 20 | 13.48 | 1461 | 394 | 3.75 / 425.65 | 6 | 82 |
7 | 13 | 320.44 | 20 | 13.98 | 760 | 212 | 3.96 / 425.86 | 6 | 79 |
8 | 13 | 55.36 | 20 | 14.32 | 384 | 110 | 4.07 / 425.97 | 6 | 73 |
9 | 8 | 0.24 | 258 | 14.24 | 300 | 1102 | 5.17 / 427.08 | 6 | 133 |
Average= | 4.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.48 | 32 | 14.47 | 430 | 199 | 0.20 / 417.02 | 7 | 11 |
2 | 7 | 2009.12 | 41 | 10.02 | 2771 | 1138 | 1.34 / 418.16 | 6 | 38 |
3 | 13 | 1948.76 | 20 | 12.47 | 2824 | 704 | 2.04 / 418.87 | 6 | 55 |
4 | 13 | 1856.60 | 20 | 12.64 | 2736 | 692 | 2.73 / 419.56 | 6 | 61 |
5 | 13 | 1424.44 | 20 | 13.03 | 2208 | 575 | 3.31 / 420.13 | 6 | 77 |
6 | 13 | 685.32 | 20 | 13.65 | 1249 | 341 | 3.65 / 420.47 | 6 | 80 |
7 | 13 | 255.28 | 20 | 14.05 | 685 | 192 | 3.84 / 420.67 | 6 | 80 |
8 | 13 | 70.64 | 20 | 14.29 | 421 | 120 | 3.96 / 420.79 | 6 | 78 |
9 | 8 | 0.00 | 254 | 14.21 | 310 | 1119 | 5.08 / 421.91 | 6 | 132 |
Average= | 4.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.64 | 32 | 14.43 | 421 | 194 | 0.19 / 412.01 | 7 | 10 |
2 | 7 | 2009.36 | 41 | 9.96 | 2769 | 1131 | 1.33 / 413.14 | 10 | 37 |
3 | 13 | 1957.80 | 20 | 12.50 | 2819 | 705 | 2.03 / 413.85 | 6 | 55 |
4 | 13 | 1873.24 | 20 | 12.66 | 2730 | 691 | 2.72 / 414.54 | 6 | 62 |
5 | 13 | 1347.44 | 20 | 13.11 | 2103 | 551 | 3.27 / 415.09 | 6 | 78 |
6 | 13 | 713.12 | 20 | 13.63 | 1275 | 348 | 3.62 / 415.44 | 6 | 79 |
7 | 13 | 200.84 | 20 | 14.12 | 598 | 169 | 3.79 / 415.61 | 6 | 77 |
8 | 13 | 49.16 | 20 | 14.34 | 381 | 109 | 3.90 / 415.72 | 6 | 75 |
9 | 8 | 0.00 | 256 | 14.20 | 305 | 1109 | 5.01 / 416.82 | 6 | 135 |
Average= | 4.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.36 | 32 | 14.46 | 423 | 196 | 0.20 / 406.95 | 7 | 12 |
2 | 7 | 2008.12 | 40 | 9.93 | 2763 | 1097 | 1.29 / 408.05 | 12 | 37 |
3 | 13 | 1935.96 | 20 | 12.52 | 2804 | 702 | 2.00 / 408.75 | 6 | 55 |
4 | 13 | 1844.80 | 20 | 12.69 | 2728 | 692 | 2.69 / 409.44 | 6 | 62 |
5 | 13 | 1432.88 | 20 | 13.05 | 2210 | 577 | 3.26 / 410.02 | 6 | 75 |
6 | 13 | 888.08 | 20 | 13.47 | 1513 | 408 | 3.67 / 410.42 | 6 | 79 |
7 | 13 | 239.40 | 20 | 14.07 | 650 | 183 | 3.86 / 410.61 | 6 | 79 |
8 | 13 | 35.68 | 20 | 14.36 | 361 | 104 | 3.96 / 410.71 | 6 | 74 |
9 | 8 | 0.16 | 256 | 14.21 | 304 | 1106 | 5.06 / 411.82 | 6 | 133 |
Average= | 4.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.32 | 32 | 14.47 | 434 | 201 | 0.20 / 401.92 | 7 | 12 |
2 | 7 | 2006.08 | 40 | 10.00 | 2789 | 1116 | 1.32 / 403.03 | 12 | 36 |
3 | 13 | 1949.60 | 20 | 12.56 | 2796 | 702 | 2.02 / 403.74 | 6 | 53 |
4 | 13 | 1851.16 | 20 | 12.72 | 2712 | 690 | 2.71 / 404.43 | 6 | 61 |
5 | 13 | 1428.16 | 20 | 13.06 | 2207 | 576 | 3.29 / 405.00 | 6 | 75 |
6 | 13 | 777.88 | 20 | 13.58 | 1371 | 372 | 3.66 / 405.38 | 6 | 81 |
7 | 13 | 149.56 | 20 | 14.18 | 530 | 150 | 3.81 / 405.53 | 6 | 77 |
8 | 13 | 36.40 | 20 | 14.34 | 370 | 106 | 3.91 / 405.63 | 6 | 76 |
9 | 8 | -0.04 | 254 | 14.18 | 311 | 1120 | 5.03 / 406.75 | 6 | 132 |
Average= | 4.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.20 | 32 | 14.43 | 446 | 206 | 0.21 / 396.86 | 7 | 13 |
2 | 7 | 2004.12 | 40 | 9.98 | 2772 | 1107 | 1.31 / 397.96 | 6 | 36 |
3 | 13 | 1945.28 | 20 | 12.52 | 2792 | 699 | 2.01 / 398.66 | 6 | 54 |
4 | 13 | 1855.64 | 20 | 12.71 | 2698 | 686 | 2.70 / 399.35 | 6 | 61 |
5 | 13 | 1534.12 | 20 | 13.02 | 2321 | 604 | 3.30 / 399.95 | 6 | 72 |
6 | 13 | 769.60 | 20 | 13.57 | 1361 | 369 | 3.67 / 400.32 | 6 | 79 |
7 | 13 | 232.80 | 20 | 14.09 | 645 | 182 | 3.85 / 400.50 | 6 | 78 |
8 | 13 | 36.12 | 20 | 14.34 | 370 | 106 | 3.96 / 400.61 | 6 | 77 |
9 | 8 | -0.08 | 254 | 14.18 | 308 | 1109 | 5.07 / 401.72 | 6 | 133 |
Average= | 4.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.60 | 32 | 14.43 | 446 | 206 | 0.21 / 391.75 | 7 | 15 |
2 | 7 | 2005.16 | 41 | 10.10 | 2801 | 1160 | 1.37 / 392.91 | 15 | 37 |
3 | 13 | 1941.80 | 20 | 12.57 | 2810 | 706 | 2.07 / 393.61 | 6 | 55 |
4 | 13 | 1851.20 | 20 | 12.72 | 2720 | 692 | 2.76 / 394.31 | 6 | 61 |
5 | 13 | 1338.32 | 20 | 13.15 | 2084 | 548 | 3.31 / 394.85 | 6 | 77 |
6 | 13 | 892.24 | 20 | 13.50 | 1507 | 407 | 3.72 / 395.26 | 6 | 81 |
7 | 13 | 212.32 | 20 | 14.09 | 620 | 175 | 3.89 / 395.43 | 6 | 80 |
8 | 13 | 28.00 | 20 | 14.35 | 358 | 103 | 4.00 / 395.54 | 6 | 79 |
9 | 8 | 0.08 | 254 | 14.17 | 309 | 1112 | 5.11 / 396.65 | 6 | 131 |
Average= | 4.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.12 | 32 | 14.47 | 442 | 205 | 0.20 / 386.70 | 7 | 11 |
2 | 7 | 2006.80 | 40 | 10.15 | 2838 | 1152 | 1.36 / 387.85 | 6 | 36 |
3 | 13 | 1941.80 | 20 | 12.59 | 2793 | 703 | 2.06 / 388.55 | 6 | 54 |
4 | 13 | 1845.40 | 20 | 12.75 | 2692 | 686 | 2.75 / 389.24 | 6 | 63 |
5 | 13 | 1417.28 | 20 | 13.10 | 2168 | 568 | 3.31 / 389.81 | 6 | 73 |
6 | 13 | 850.24 | 20 | 13.53 | 1456 | 394 | 3.71 / 390.20 | 6 | 81 |
7 | 13 | 103.80 | 20 | 14.23 | 463 | 132 | 3.84 / 390.33 | 6 | 79 |
8 | 13 | 52.92 | 20 | 14.29 | 397 | 113 | 3.95 / 390.45 | 6 | 81 |
9 | 8 | 0.04 | 251 | 14.20 | 307 | 1094 | 5.05 / 391.54 | 6 | 131 |
Average= | 4.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.20 | 32 | 14.47 | 428 | 198 | 0.20 / 381.70 | 7 | 10 |
2 | 7 | 2007.24 | 41 | 10.17 | 2806 | 1170 | 1.37 / 382.87 | 6 | 36 |
3 | 13 | 1948.64 | 20 | 12.57 | 2802 | 704 | 2.07 / 383.58 | 6 | 56 |
4 | 13 | 1858.16 | 20 | 12.72 | 2723 | 693 | 2.77 / 384.27 | 6 | 62 |
5 | 13 | 1240.20 | 20 | 13.22 | 1960 | 518 | 3.28 / 384.79 | 6 | 79 |
6 | 13 | 697.92 | 20 | 13.67 | 1262 | 345 | 3.63 / 385.13 | 6 | 81 |
7 | 13 | 160.36 | 20 | 14.18 | 544 | 154 | 3.78 / 385.29 | 6 | 80 |
8 | 13 | 32.92 | 20 | 14.35 | 363 | 104 | 3.89 / 385.39 | 6 | 78 |
9 | 8 | 0.04 | 254 | 14.18 | 306 | 1102 | 4.99 / 386.49 | 6 | 132 |
Average= | 4.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.36 | 32 | 14.46 | 418 | 193 | 0.19 / 376.70 | 7 | 10 |
2 | 7 | 2002.84 | 40 | 10.19 | 2791 | 1138 | 1.33 / 377.83 | 6 | 38 |
3 | 13 | 1938.76 | 20 | 12.55 | 2808 | 705 | 2.04 / 378.54 | 6 | 54 |
4 | 13 | 1848.80 | 20 | 12.75 | 2696 | 687 | 2.72 / 379.23 | 6 | 62 |
5 | 13 | 1347.68 | 20 | 13.15 | 2100 | 552 | 3.28 / 379.78 | 6 | 75 |
6 | 13 | 714.44 | 20 | 13.65 | 1280 | 349 | 3.63 / 380.13 | 6 | 81 |
7 | 13 | 179.04 | 20 | 14.15 | 571 | 162 | 3.79 / 380.29 | 6 | 80 |
8 | 13 | 39.16 | 20 | 14.34 | 370 | 106 | 3.89 / 380.40 | 6 | 78 |
9 | 8 | 0.08 | 258 | 14.21 | 302 | 1107 | 5.00 / 381.50 | 6 | 133 |
Average= | 4.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.80 | 32 | 14.49 | 427 | 198 | 0.20 / 371.51 | 7 | 10 |
2 | 7 | 2001.92 | 40 | 10.27 | 2809 | 1154 | 1.35 / 372.67 | 10 | 38 |
3 | 13 | 1931.24 | 20 | 12.59 | 2786 | 702 | 2.05 / 373.37 | 6 | 56 |
4 | 13 | 1833.12 | 20 | 12.77 | 2669 | 682 | 2.74 / 374.05 | 6 | 62 |
5 | 13 | 1519.20 | 20 | 13.06 | 2306 | 602 | 3.34 / 374.65 | 6 | 74 |
6 | 13 | 973.20 | 20 | 13.44 | 1616 | 434 | 3.77 / 375.09 | 6 | 81 |
7 | 13 | 288.52 | 20 | 14.03 | 723 | 203 | 3.97 / 375.29 | 6 | 82 |
8 | 13 | 37.04 | 20 | 14.35 | 364 | 104 | 4.08 / 375.39 | 6 | 79 |
9 | 13 | 5.96 | 20 | 14.37 | 318 | 91 | 4.17 / 375.48 | 6 | 77 |
10 | 8 | 0.04 | 235 | 14.17 | 306 | 1019 | 5.19 / 376.50 | 6 | 133 |
Average= | 4.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.48 | 32 | 14.43 | 429 | 198 | 0.20 / 366.54 | 7 | 10 |
2 | 7 | 2000.96 | 41 | 10.31 | 2812 | 1189 | 1.39 / 367.72 | 10 | 38 |
3 | 13 | 1929.80 | 20 | 12.57 | 2774 | 697 | 2.08 / 368.42 | 6 | 54 |
4 | 13 | 1738.36 | 20 | 12.88 | 2567 | 661 | 2.75 / 369.08 | 6 | 65 |
5 | 13 | 1311.92 | 20 | 13.19 | 2046 | 540 | 3.29 / 369.62 | 6 | 77 |
6 | 13 | 659.16 | 20 | 13.70 | 1210 | 332 | 3.62 / 369.95 | 6 | 82 |
7 | 13 | 219.56 | 20 | 14.12 | 623 | 176 | 3.79 / 370.13 | 6 | 81 |
8 | 13 | 51.76 | 20 | 14.33 | 385 | 110 | 3.90 / 370.24 | 6 | 78 |
9 | 8 | 0.08 | 251 | 14.22 | 301 | 1074 | 4.98 / 371.31 | 6 | 132 |
Average= | 4.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.92 | 31 | 14.49 | 424 | 190 | 0.19 / 361.43 | 7 | 10 |
2 | 7 | 2010.40 | 40 | 10.36 | 2850 | 1181 | 1.37 / 362.61 | 6 | 38 |
3 | 13 | 1944.88 | 20 | 12.59 | 2816 | 709 | 2.08 / 363.32 | 6 | 57 |
4 | 13 | 1847.48 | 20 | 12.75 | 2698 | 688 | 2.77 / 364.01 | 6 | 63 |
5 | 13 | 1526.92 | 20 | 13.04 | 2321 | 605 | 3.37 / 364.61 | 6 | 73 |
6 | 13 | 744.68 | 20 | 13.62 | 1322 | 360 | 3.73 / 364.97 | 6 | 82 |
7 | 13 | 196.92 | 20 | 14.14 | 595 | 168 | 3.90 / 365.14 | 6 | 79 |
8 | 13 | 47.24 | 20 | 14.34 | 377 | 108 | 4.01 / 365.25 | 6 | 77 |
9 | 8 | 0.08 | 254 | 14.22 | 301 | 1087 | 5.10 / 366.34 | 6 | 131 |
Average= | 4.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.00 | 31 | 14.51 | 416 | 187 | 0.19 / 356.34 | 7 | 10 |
2 | 7 | 2002.40 | 40 | 10.46 | 2828 | 1183 | 1.37 / 357.52 | 10 | 40 |
3 | 13 | 1937.44 | 20 | 12.55 | 2831 | 711 | 2.08 / 358.23 | 6 | 58 |
4 | 13 | 1844.96 | 20 | 12.74 | 2712 | 691 | 2.77 / 358.92 | 6 | 63 |
5 | 13 | 1421.48 | 20 | 13.10 | 2195 | 575 | 3.35 / 359.50 | 6 | 79 |
6 | 13 | 861.04 | 20 | 13.54 | 1471 | 398 | 3.75 / 359.90 | 6 | 83 |
7 | 13 | 188.68 | 20 | 14.15 | 581 | 164 | 3.91 / 360.06 | 6 | 79 |
8 | 13 | 46.36 | 20 | 14.37 | 374 | 107 | 4.02 / 360.17 | 6 | 74 |
9 | 8 | 0.44 | 251 | 14.21 | 300 | 1070 | 5.09 / 361.24 | 6 | 130 |
Average= | 4.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.32 | 31 | 14.49 | 424 | 190 | 0.19 / 351.35 | 7 | 10 |
2 | 7 | 2005.84 | 40 | 10.52 | 2826 | 1189 | 1.38 / 352.53 | 10 | 37 |
3 | 13 | 1946.48 | 20 | 12.60 | 2789 | 703 | 2.08 / 353.24 | 6 | 56 |
4 | 13 | 1859.16 | 20 | 12.77 | 2716 | 694 | 2.78 / 353.93 | 6 | 62 |
5 | 13 | 1326.60 | 20 | 13.18 | 2066 | 545 | 3.32 / 354.48 | 6 | 79 |
6 | 13 | 680.60 | 20 | 13.71 | 1230 | 337 | 3.66 / 354.81 | 6 | 83 |
7 | 13 | 148.72 | 20 | 14.21 | 525 | 149 | 3.81 / 354.96 | 6 | 77 |
8 | 13 | 36.80 | 20 | 14.39 | 359 | 103 | 3.91 / 355.07 | 6 | 73 |
9 | 8 | 0.00 | 254 | 14.21 | 301 | 1086 | 5.00 / 356.15 | 6 | 134 |
Average= | 4.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.28 | 31 | 14.45 | 423 | 189 | 0.19 / 346.27 | 7 | 10 |
2 | 7 | 2003.92 | 41 | 10.47 | 2817 | 1209 | 1.40 / 347.48 | 10 | 38 |
3 | 13 | 1941.52 | 20 | 12.59 | 2802 | 706 | 2.10 / 348.18 | 6 | 56 |
4 | 13 | 1844.72 | 20 | 12.78 | 2687 | 687 | 2.79 / 348.87 | 6 | 63 |
5 | 13 | 1320.32 | 20 | 13.18 | 2054 | 541 | 3.33 / 349.41 | 6 | 78 |
6 | 13 | 881.40 | 20 | 13.55 | 1464 | 397 | 3.73 / 349.81 | 6 | 79 |
7 | 13 | 197.36 | 20 | 14.15 | 589 | 167 | 3.90 / 349.97 | 6 | 80 |
8 | 13 | 45.68 | 20 | 14.38 | 366 | 105 | 4.00 / 350.08 | 6 | 74 |
9 | 8 | 0.04 | 254 | 14.22 | 298 | 1076 | 5.08 / 351.16 | 6 | 133 |
Average= | 4.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.00 | 31 | 14.53 | 417 | 188 | 0.19 / 341.24 | 7 | 10 |
2 | 7 | 2002.16 | 40 | 10.61 | 2832 | 1202 | 1.39 / 342.44 | 10 | 38 |
3 | 13 | 1932.52 | 20 | 12.60 | 2808 | 708 | 2.10 / 343.14 | 6 | 57 |
4 | 13 | 1839.60 | 20 | 12.78 | 2701 | 690 | 2.79 / 343.84 | 6 | 63 |
5 | 13 | 1407.36 | 20 | 13.15 | 2171 | 571 | 3.36 / 344.41 | 6 | 77 |
6 | 13 | 744.40 | 20 | 13.66 | 1322 | 361 | 3.72 / 344.77 | 6 | 82 |
7 | 13 | 182.44 | 20 | 14.18 | 572 | 162 | 3.88 / 344.93 | 6 | 78 |
8 | 8 | 0.20 | 272 | 14.26 | 296 | 1148 | 5.03 / 346.08 | 6 | 130 |
Average= | 4.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.08 | 31 | 14.53 | 414 | 186 | 0.19 / 336.20 | 7 | 9 |
2 | 7 | 2009.52 | 40 | 10.59 | 2831 | 1199 | 1.39 / 337.40 | 9 | 38 |
3 | 13 | 1956.28 | 20 | 12.61 | 2822 | 712 | 2.10 / 338.11 | 6 | 56 |
4 | 13 | 1867.52 | 20 | 12.77 | 2722 | 695 | 2.79 / 338.80 | 6 | 62 |
5 | 13 | 1422.72 | 20 | 13.14 | 2172 | 571 | 3.36 / 339.37 | 6 | 76 |
6 | 13 | 672.84 | 20 | 13.73 | 1225 | 336 | 3.70 / 339.71 | 6 | 81 |
7 | 13 | 149.24 | 20 | 14.24 | 521 | 148 | 3.85 / 339.86 | 6 | 75 |
8 | 13 | 78.32 | 20 | 14.36 | 413 | 119 | 3.97 / 339.98 | 6 | 71 |
9 | 8 | 0.04 | 254 | 14.27 | 295 | 1069 | 5.04 / 341.05 | 7 | 131 |
Average= | 4.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.00 | 31 | 14.56 | 411 | 186 | 0.19 / 331.18 | 7 | 9 |
2 | 7 | 2009.20 | 40 | 10.71 | 2831 | 1213 | 1.40 / 332.39 | 9 | 38 |
3 | 13 | 1945.20 | 20 | 12.59 | 2837 | 714 | 2.11 / 333.11 | 6 | 56 |
4 | 13 | 1857.60 | 20 | 12.77 | 2727 | 696 | 2.81 / 333.81 | 6 | 62 |
5 | 13 | 1340.28 | 20 | 13.22 | 2075 | 549 | 3.36 / 334.35 | 6 | 76 |
6 | 13 | 603.60 | 20 | 13.80 | 1143 | 315 | 3.67 / 334.67 | 6 | 80 |
7 | 13 | 176.76 | 20 | 14.21 | 565 | 161 | 3.83 / 334.83 | 6 | 76 |
8 | 13 | 41.36 | 20 | 14.41 | 357 | 103 | 3.94 / 334.93 | 6 | 68 |
9 | 8 | 0.04 | 254 | 14.25 | 298 | 1079 | 5.02 / 336.01 | 7 | 132 |
Average= | 4.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.52 | 31 | 14.54 | 422 | 190 | 0.19 / 326.15 | 7 | 9 |
2 | 7 | 2001.20 | 41 | 10.80 | 2831 | 1254 | 1.44 / 327.40 | 6 | 37 |
3 | 13 | 1934.16 | 20 | 12.64 | 2793 | 706 | 2.15 / 328.11 | 6 | 56 |
4 | 13 | 1842.40 | 20 | 12.83 | 2688 | 690 | 2.84 / 328.80 | 6 | 63 |
5 | 13 | 1303.92 | 20 | 13.24 | 2045 | 542 | 3.38 / 329.34 | 6 | 77 |
6 | 13 | 656.32 | 20 | 13.76 | 1210 | 333 | 3.71 / 329.67 | 6 | 81 |
7 | 13 | 128.00 | 20 | 14.30 | 482 | 138 | 3.85 / 329.81 | 6 | 71 |
8 | 13 | 66.72 | 20 | 14.39 | 393 | 113 | 3.97 / 329.92 | 6 | 67 |
9 | 8 | 0.00 | 256 | 14.29 | 293 | 1072 | 5.04 / 331.00 | 7 | 139 |
Average= | 4.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.68 | 31 | 14.51 | 431 | 194 | 0.19 / 321.14 | 7 | 9 |
2 | 7 | 2007.96 | 40 | 10.80 | 2836 | 1225 | 1.42 / 322.37 | 9 | 37 |
3 | 13 | 1938.84 | 20 | 12.65 | 2798 | 708 | 2.13 / 323.07 | 6 | 55 |
4 | 13 | 1842.48 | 20 | 12.80 | 2712 | 694 | 2.82 / 323.77 | 6 | 63 |
5 | 13 | 1203.28 | 20 | 13.33 | 1906 | 508 | 3.33 / 324.28 | 6 | 79 |
6 | 13 | 669.08 | 20 | 13.78 | 1223 | 337 | 3.67 / 324.61 | 6 | 79 |
7 | 13 | 145.52 | 20 | 14.27 | 517 | 148 | 3.81 / 324.76 | 6 | 72 |
8 | 13 | 74.96 | 20 | 14.38 | 407 | 117 | 3.93 / 324.88 | 6 | 68 |
9 | 8 | 0.08 | 256 | 14.28 | 296 | 1082 | 5.01 / 325.96 | 7 | 134 |
Average= | 4.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.40 | 31 | 14.57 | 416 | 188 | 0.19 / 316.10 | 7 | 9 |
2 | 7 | 2009.04 | 40 | 10.89 | 2843 | 1238 | 1.43 / 317.34 | 9 | 38 |
3 | 13 | 1937.88 | 20 | 12.67 | 2817 | 714 | 2.14 / 318.05 | 6 | 56 |
4 | 13 | 1841.04 | 20 | 12.82 | 2686 | 689 | 2.83 / 318.74 | 6 | 63 |
5 | 13 | 1294.48 | 20 | 13.28 | 2017 | 536 | 3.36 / 319.28 | 6 | 78 |
6 | 13 | 654.84 | 20 | 13.79 | 1206 | 333 | 3.70 / 319.61 | 6 | 79 |
7 | 13 | 210.28 | 20 | 14.20 | 609 | 173 | 3.87 / 319.78 | 6 | 76 |
8 | 13 | 25.76 | 20 | 14.45 | 331 | 96 | 3.97 / 319.88 | 6 | 63 |
9 | 8 | 0.08 | 256 | 14.26 | 293 | 1070 | 5.04 / 320.95 | 6 | 139 |
Average= | 4.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.56 | 31 | 14.51 | 437 | 197 | 0.20 / 311.07 | 7 | 8 |
2 | 7 | 2006.16 | 40 | 10.97 | 2847 | 1249 | 1.45 / 312.32 | 8 | 36 |
3 | 13 | 1937.76 | 20 | 12.66 | 2828 | 716 | 2.16 / 313.04 | 6 | 56 |
4 | 13 | 1843.12 | 20 | 12.85 | 2714 | 697 | 2.86 / 313.73 | 6 | 62 |
5 | 13 | 1203.72 | 20 | 13.37 | 1907 | 510 | 3.37 / 314.24 | 6 | 79 |
6 | 13 | 654.56 | 20 | 13.81 | 1206 | 333 | 3.70 / 314.58 | 6 | 80 |
7 | 13 | 132.20 | 20 | 14.30 | 495 | 142 | 3.84 / 314.72 | 6 | 72 |
8 | 13 | 68.16 | 20 | 14.38 | 401 | 115 | 3.96 / 314.83 | 6 | 69 |
9 | 8 | 0.00 | 254 | 14.28 | 297 | 1077 | 5.04 / 315.91 | 7 | 140 |
Average= | 4.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.00 | 31 | 14.58 | 417 | 188 | 0.19 / 306.03 | 7 | 8 |
2 | 7 | 2002.12 | 41 | 11.07 | 2860 | 1298 | 1.49 / 307.33 | 6 | 36 |
3 | 13 | 1930.76 | 20 | 12.71 | 2812 | 715 | 2.20 / 308.04 | 6 | 56 |
4 | 13 | 1839.92 | 20 | 12.85 | 2708 | 696 | 2.90 / 308.74 | 6 | 62 |
5 | 13 | 1118.40 | 20 | 13.43 | 1812 | 487 | 3.38 / 309.23 | 6 | 79 |
6 | 13 | 592.16 | 20 | 13.88 | 1124 | 312 | 3.70 / 309.54 | 6 | 78 |
7 | 13 | 154.92 | 20 | 14.27 | 532 | 152 | 3.85 / 309.69 | 6 | 73 |
8 | 13 | 38.00 | 20 | 14.44 | 356 | 103 | 3.95 / 309.79 | 6 | 68 |
9 | 8 | -0.04 | 254 | 14.25 | 299 | 1082 | 5.03 / 310.87 | 6 | 139 |
Average= | 4.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.48 | 31 | 14.54 | 422 | 190 | 0.19 / 300.80 | 7 | 8 |
2 | 7 | 2010.28 | 40 | 11.17 | 2854 | 1275 | 1.47 / 302.07 | 8 | 36 |
3 | 13 | 1940.28 | 20 | 12.73 | 2817 | 717 | 2.18 / 302.79 | 6 | 55 |
4 | 13 | 1841.96 | 20 | 12.88 | 2699 | 695 | 2.88 / 303.48 | 6 | 61 |
5 | 13 | 1529.92 | 20 | 13.19 | 2323 | 613 | 3.49 / 304.10 | 6 | 72 |
6 | 13 | 752.08 | 20 | 13.74 | 1334 | 367 | 3.86 / 304.46 | 6 | 80 |
7 | 13 | 186.40 | 20 | 14.25 | 578 | 165 | 4.02 / 304.63 | 6 | 75 |
8 | 13 | 93.80 | 20 | 14.36 | 442 | 127 | 4.15 / 304.75 | 6 | 72 |
9 | 8 | 0.08 | 256 | 14.29 | 297 | 1086 | 5.24 / 305.84 | 7 | 141 |
Average= | 4.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.36 | 31 | 14.58 | 438 | 198 | 0.20 / 295.79 | 7 | 7 |
2 | 7 | 2001.12 | 41 | 11.18 | 2866 | 1314 | 1.51 / 297.11 | 7 | 36 |
3 | 13 | 1922.16 | 20 | 12.77 | 2785 | 711 | 2.22 / 297.82 | 6 | 56 |
4 | 13 | 1621.76 | 20 | 13.11 | 2430 | 637 | 2.86 / 298.46 | 6 | 69 |
5 | 13 | 1208.32 | 20 | 13.41 | 1933 | 518 | 3.38 / 298.97 | 6 | 78 |
6 | 13 | 653.12 | 20 | 13.84 | 1205 | 334 | 3.71 / 299.31 | 6 | 80 |
7 | 13 | 108.52 | 20 | 14.34 | 464 | 133 | 3.85 / 299.44 | 6 | 70 |
8 | 13 | 29.80 | 20 | 14.45 | 342 | 99 | 3.94 / 299.54 | 6 | 64 |
9 | 8 | 0.04 | 251 | 14.26 | 298 | 1067 | 5.01 / 300.61 | 7 | 138 |
Average= | 4.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.36 | 31 | 14.60 | 416 | 188 | 0.19 / 290.65 | 7 | 7 |
2 | 7 | 2006.12 | 41 | 11.30 | 2870 | 1330 | 1.52 / 291.98 | 7 | 37 |
3 | 13 | 1936.32 | 20 | 12.77 | 2814 | 719 | 2.24 / 292.70 | 6 | 56 |
4 | 13 | 1839.48 | 20 | 12.93 | 2701 | 698 | 2.94 / 293.40 | 6 | 63 |
5 | 13 | 1297.20 | 20 | 13.37 | 2038 | 545 | 3.48 / 293.94 | 6 | 77 |
6 | 13 | 633.24 | 20 | 13.87 | 1173 | 325 | 3.81 / 294.27 | 6 | 80 |
7 | 13 | 106.72 | 20 | 14.34 | 460 | 132 | 3.94 / 294.40 | 6 | 71 |
8 | 13 | 30.76 | 20 | 14.44 | 348 | 101 | 4.04 / 294.50 | 6 | 65 |
9 | 13 | 15.52 | 20 | 14.39 | 326 | 94 | 4.13 / 294.60 | 6 | 65 |
10 | 8 | 0.12 | 233 | 14.26 | 301 | 1000 | 5.13 / 295.60 | 7 | 137 |
Average= | 4.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.24 | 31 | 14.58 | 423 | 191 | 0.19 / 285.62 | 7 | 8 |
2 | 7 | 2004.04 | 40 | 11.50 | 2869 | 1320 | 1.51 / 286.94 | 6 | 37 |
3 | 13 | 1932.84 | 20 | 12.84 | 2801 | 719 | 2.23 / 287.66 | 6 | 55 |
4 | 13 | 1736.48 | 20 | 13.07 | 2570 | 672 | 2.90 / 288.33 | 6 | 66 |
5 | 13 | 1295.16 | 20 | 13.39 | 2029 | 543 | 3.45 / 288.88 | 6 | 76 |
6 | 13 | 531.60 | 20 | 13.96 | 1052 | 294 | 3.74 / 289.17 | 6 | 78 |
7 | 13 | 110.32 | 20 | 14.36 | 464 | 133 | 3.87 / 289.30 | 6 | 70 |
8 | 13 | 30.24 | 20 | 14.46 | 341 | 99 | 3.97 / 289.40 | 6 | 64 |
9 | 8 | 0.08 | 251 | 14.27 | 296 | 1060 | 5.03 / 290.46 | 7 | 136 |
Average= | 4.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.08 | 31 | 14.58 | 431 | 195 | 0.19 / 280.41 | 7 | 7 |
2 | 7 | 2008.60 | 40 | 11.61 | 2881 | 1338 | 1.53 / 281.75 | 6 | 37 |
3 | 13 | 1938.96 | 20 | 12.84 | 2839 | 729 | 2.26 / 282.48 | 6 | 55 |
4 | 13 | 1851.00 | 20 | 12.99 | 2723 | 707 | 2.97 / 283.19 | 6 | 61 |
5 | 13 | 1191.64 | 20 | 13.47 | 1897 | 511 | 3.48 / 283.70 | 6 | 77 |
6 | 13 | 757.68 | 20 | 13.79 | 1355 | 374 | 3.85 / 284.07 | 6 | 78 |
7 | 13 | 188.28 | 20 | 14.27 | 585 | 167 | 4.02 / 284.24 | 6 | 74 |
8 | 13 | 41.72 | 20 | 14.45 | 365 | 105 | 4.13 / 284.35 | 6 | 68 |
9 | 8 | 0.16 | 251 | 14.28 | 303 | 1086 | 5.21 / 285.43 | 6 | 131 |
Average= | 4.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.44 | 31 | 14.54 | 436 | 197 | 0.20 / 275.23 | 7 | 8 |
2 | 7 | 2010.72 | 40 | 11.71 | 2881 | 1349 | 1.55 / 276.58 | 8 | 39 |
3 | 13 | 1935.84 | 20 | 12.88 | 2817 | 726 | 2.27 / 277.31 | 6 | 55 |
4 | 13 | 1838.92 | 20 | 13.03 | 2714 | 707 | 2.98 / 278.01 | 6 | 62 |
5 | 13 | 1188.40 | 20 | 13.49 | 1902 | 513 | 3.49 / 278.53 | 6 | 77 |
6 | 13 | 650.40 | 20 | 13.90 | 1202 | 334 | 3.83 / 278.86 | 6 | 78 |
7 | 13 | 190.44 | 20 | 14.27 | 589 | 168 | 3.99 / 279.03 | 6 | 75 |
8 | 13 | 48.76 | 20 | 14.44 | 374 | 108 | 4.10 / 279.14 | 6 | 67 |
9 | 8 | 0.16 | 251 | 14.29 | 302 | 1083 | 5.19 / 280.22 | 7 | 133 |
Average= | 4.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.84 | 31 | 14.60 | 434 | 196 | 0.20 / 270.06 | 7 | 7 |
2 | 7 | 2001.84 | 40 | 11.87 | 2875 | 1365 | 1.56 / 271.42 | 7 | 41 |
3 | 13 | 1931.52 | 20 | 12.93 | 2792 | 722 | 2.28 / 272.15 | 6 | 56 |
4 | 13 | 1833.68 | 20 | 13.07 | 2681 | 701 | 2.98 / 272.85 | 6 | 62 |
5 | 13 | 1178.68 | 20 | 13.51 | 1888 | 510 | 3.49 / 273.36 | 6 | 78 |
6 | 13 | 631.88 | 20 | 13.91 | 1189 | 331 | 3.83 / 273.69 | 6 | 79 |
7 | 13 | 100.72 | 20 | 14.38 | 462 | 133 | 3.96 / 273.82 | 6 | 71 |
8 | 13 | 29.40 | 20 | 14.45 | 355 | 103 | 4.06 / 273.92 | 6 | 65 |
9 | 13 | 14.96 | 20 | 14.41 | 332 | 96 | 4.16 / 274.02 | 6 | 64 |
10 | 8 | 0.08 | 231 | 14.23 | 309 | 1016 | 5.17 / 275.03 | 7 | 135 |
Average= | 4.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.68 | 31 | 14.60 | 437 | 198 | 0.20 / 264.95 | 7 | 7 |
2 | 7 | 2003.20 | 40 | 11.96 | 2884 | 1380 | 1.58 / 266.33 | 6 | 42 |
3 | 13 | 1925.00 | 20 | 12.95 | 2789 | 722 | 2.30 / 267.05 | 6 | 57 |
4 | 13 | 1621.84 | 20 | 13.25 | 2426 | 643 | 2.94 / 267.70 | 6 | 69 |
5 | 13 | 1205.68 | 20 | 13.52 | 1928 | 521 | 3.46 / 268.22 | 6 | 80 |
6 | 13 | 538.72 | 20 | 13.98 | 1068 | 299 | 3.76 / 268.52 | 6 | 80 |
7 | 13 | 104.68 | 20 | 14.37 | 473 | 136 | 3.90 / 268.65 | 6 | 72 |
8 | 13 | 55.96 | 20 | 14.40 | 398 | 115 | 4.01 / 268.77 | 6 | 69 |
9 | 8 | 0.12 | 246 | 14.28 | 312 | 1096 | 5.11 / 269.86 | 7 | 131 |
Average= | 4.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.12 | 31 | 14.58 | 431 | 195 | 0.19 / 259.74 | 7 | 7 |
2 | 7 | 2006.00 | 40 | 12.14 | 2883 | 1400 | 1.59 / 261.14 | 7 | 44 |
3 | 13 | 1937.48 | 20 | 12.97 | 2817 | 731 | 2.33 / 261.87 | 6 | 58 |
4 | 13 | 1841.32 | 20 | 13.10 | 2717 | 712 | 3.04 / 262.58 | 6 | 64 |
5 | 13 | 1274.56 | 20 | 13.48 | 2010 | 542 | 3.58 / 263.12 | 6 | 79 |
6 | 13 | 496.60 | 20 | 14.03 | 1006 | 282 | 3.86 / 263.40 | 6 | 78 |
7 | 13 | 106.92 | 20 | 14.39 | 462 | 133 | 3.99 / 263.54 | 6 | 68 |
8 | 13 | 58.20 | 20 | 14.44 | 391 | 113 | 4.11 / 263.65 | 6 | 63 |
9 | 13 | 29.64 | 20 | 14.44 | 346 | 100 | 4.21 / 263.75 | 6 | 60 |
10 | 8 | 0.08 | 230 | 14.29 | 305 | 1002 | 5.21 / 264.75 | 7 | 132 |
Average= | 4.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.20 | 31 | 14.57 | 446 | 201 | 0.20 / 254.63 | 7 | 7 |
2 | 7 | 2003.24 | 40 | 12.28 | 2881 | 1415 | 1.62 / 256.05 | 7 | 45 |
3 | 13 | 1926.20 | 20 | 13.03 | 2798 | 729 | 2.35 / 256.78 | 6 | 58 |
4 | 13 | 1631.96 | 20 | 13.29 | 2438 | 648 | 2.99 / 257.43 | 6 | 70 |
5 | 13 | 1004.96 | 20 | 13.66 | 1676 | 458 | 3.45 / 257.88 | 6 | 82 |
6 | 13 | 569.60 | 20 | 14.00 | 1103 | 309 | 3.76 / 258.19 | 6 | 80 |
7 | 13 | 134.32 | 20 | 14.36 | 510 | 146 | 3.91 / 258.34 | 6 | 71 |
8 | 13 | 70.92 | 20 | 14.43 | 409 | 118 | 4.03 / 258.46 | 6 | 67 |
9 | 13 | 17.32 | 20 | 14.49 | 328 | 95 | 4.12 / 258.55 | 6 | 60 |
10 | 8 | 0.12 | 228 | 14.28 | 304 | 990 | 5.11 / 259.54 | 7 | 134 |
Average= | 4.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.96 | 31 | 14.60 | 438 | 198 | 0.20 / 249.49 | 7 | 7 |
2 | 7 | 2004.52 | 41 | 12.38 | 2889 | 1466 | 1.66 / 250.95 | 7 | 45 |
3 | 13 | 1922.60 | 20 | 13.04 | 2812 | 733 | 2.40 / 251.68 | 6 | 59 |
4 | 13 | 1723.72 | 20 | 13.26 | 2557 | 678 | 3.08 / 252.36 | 6 | 69 |
5 | 13 | 1064.24 | 20 | 13.65 | 1743 | 476 | 3.55 / 252.84 | 6 | 82 |
6 | 13 | 505.84 | 20 | 14.04 | 1024 | 288 | 3.84 / 253.13 | 6 | 79 |
7 | 13 | 103.60 | 20 | 14.41 | 461 | 133 | 3.97 / 253.26 | 6 | 69 |
8 | 13 | 32.40 | 20 | 14.49 | 351 | 102 | 4.07 / 253.36 | 6 | 62 |
9 | 8 | 0.16 | 246 | 14.29 | 305 | 1072 | 5.15 / 254.43 | 7 | 134 |
Average= | 4.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.12 | 31 | 14.63 | 433 | 196 | 0.20 / 244.38 | 7 | 7 |
2 | 7 | 2010.32 | 40 | 12.46 | 2901 | 1446 | 1.64 / 245.83 | 7 | 46 |
3 | 13 | 1922.88 | 20 | 13.06 | 2802 | 732 | 2.37 / 246.56 | 6 | 59 |
4 | 13 | 1617.76 | 20 | 13.33 | 2432 | 648 | 3.02 / 247.21 | 6 | 71 |
5 | 13 | 977.60 | 20 | 13.71 | 1630 | 447 | 3.47 / 247.65 | 6 | 82 |
6 | 13 | 543.96 | 20 | 14.03 | 1067 | 299 | 3.77 / 247.95 | 6 | 79 |
7 | 13 | 107.00 | 20 | 14.40 | 474 | 137 | 3.91 / 248.09 | 6 | 72 |
8 | 13 | 54.20 | 20 | 14.43 | 388 | 112 | 4.02 / 248.20 | 6 | 68 |
9 | 8 | 0.08 | 245 | 14.30 | 310 | 1086 | 5.10 / 249.29 | 7 | 136 |
Average= | 4.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.92 | 31 | 14.61 | 431 | 195 | 0.20 / 239.28 | 7 | 8 |
2 | 7 | 2002.40 | 40 | 12.57 | 2878 | 1447 | 1.64 / 240.73 | 8 | 45 |
3 | 13 | 1917.56 | 20 | 13.10 | 2793 | 732 | 2.37 / 241.46 | 6 | 57 |
4 | 13 | 1608.96 | 20 | 13.35 | 2437 | 651 | 3.02 / 242.11 | 6 | 68 |
5 | 13 | 1068.16 | 20 | 13.67 | 1753 | 479 | 3.50 / 242.59 | 6 | 79 |
6 | 13 | 414.96 | 20 | 14.14 | 900 | 255 | 3.76 / 242.84 | 6 | 75 |
7 | 13 | 101.84 | 20 | 14.42 | 466 | 134 | 3.89 / 242.98 | 6 | 70 |
8 | 13 | 52.80 | 20 | 14.43 | 391 | 113 | 4.01 / 243.09 | 6 | 68 |
9 | 8 | 0.04 | 244 | 14.29 | 313 | 1091 | 5.10 / 244.18 | 7 | 134 |
Average= | 4.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.32 | 31 | 14.65 | 422 | 192 | 0.19 / 234.17 | 7 | 8 |
2 | 7 | 2012.00 | 40 | 12.68 | 2887 | 1464 | 1.66 / 235.63 | 8 | 46 |
3 | 13 | 1930.36 | 20 | 13.13 | 2804 | 736 | 2.39 / 236.37 | 6 | 57 |
4 | 13 | 1630.08 | 20 | 13.35 | 2453 | 655 | 3.05 / 237.02 | 6 | 68 |
5 | 13 | 1086.48 | 20 | 13.67 | 1781 | 487 | 3.53 / 237.51 | 6 | 78 |
6 | 13 | 436.20 | 20 | 14.14 | 926 | 262 | 3.80 / 237.77 | 6 | 75 |
7 | 13 | 101.68 | 20 | 14.42 | 464 | 134 | 3.93 / 237.90 | 6 | 70 |
8 | 13 | 30.00 | 20 | 14.49 | 353 | 102 | 4.03 / 238.01 | 6 | 65 |
9 | 8 | 0.08 | 244 | 14.28 | 310 | 1080 | 5.11 / 239.09 | 6 | 135 |
Average= | 4.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.52 | 31 | 14.64 | 439 | 199 | 0.20 / 229.16 | 7 | 8 |
2 | 7 | 2010.36 | 40 | 12.72 | 2890 | 1470 | 1.67 / 230.63 | 6 | 45 |
3 | 13 | 1928.28 | 20 | 13.15 | 2807 | 738 | 2.41 / 231.37 | 6 | 56 |
4 | 13 | 1510.48 | 20 | 13.43 | 2307 | 620 | 3.03 / 231.99 | 6 | 70 |
5 | 13 | 874.08 | 20 | 13.81 | 1516 | 419 | 3.45 / 232.40 | 6 | 77 |
6 | 13 | 442.56 | 20 | 14.13 | 944 | 267 | 3.71 / 232.67 | 6 | 75 |
7 | 13 | 99.76 | 20 | 14.41 | 474 | 137 | 3.85 / 232.81 | 6 | 72 |
8 | 13 | 23.76 | 20 | 14.49 | 349 | 101 | 3.95 / 232.91 | 6 | 67 |
9 | 8 | 0.04 | 239 | 14.28 | 312 | 1065 | 5.02 / 233.97 | 6 | 130 |
Average= | 4.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.40 | 31 | 14.64 | 435 | 197 | 0.20 / 223.98 | 7 | 8 |
2 | 7 | 2002.60 | 40 | 12.79 | 2888 | 1478 | 1.67 / 225.46 | 6 | 46 |
3 | 13 | 1916.08 | 20 | 13.16 | 2804 | 738 | 2.41 / 226.20 | 6 | 56 |
4 | 13 | 1615.32 | 20 | 13.37 | 2445 | 654 | 3.07 / 226.85 | 6 | 67 |
5 | 13 | 1175.20 | 20 | 13.63 | 1901 | 518 | 3.58 / 227.37 | 6 | 77 |
6 | 13 | 393.80 | 20 | 14.18 | 876 | 248 | 3.83 / 227.62 | 6 | 75 |
7 | 13 | 81.64 | 20 | 14.44 | 446 | 129 | 3.96 / 227.75 | 6 | 70 |
8 | 13 | 3.68 | 20 | 14.52 | 324 | 94 | 4.06 / 227.84 | 6 | 66 |
9 | 8 | 0.00 | 242 | 14.27 | 323 | 1115 | 5.17 / 228.96 | 7 | 131 |
Average= | 4.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.88 | 31 | 14.65 | 425 | 193 | 0.19 / 218.94 | 7 | 8 |
2 | 7 | 2006.40 | 40 | 12.81 | 2890 | 1481 | 1.67 / 220.42 | 8 | 46 |
3 | 13 | 1935.48 | 20 | 13.17 | 2813 | 741 | 2.41 / 221.17 | 6 | 56 |
4 | 13 | 1529.44 | 20 | 13.44 | 2341 | 629 | 3.04 / 221.79 | 6 | 70 |
5 | 13 | 1098.08 | 20 | 13.70 | 1795 | 492 | 3.54 / 222.29 | 6 | 77 |
6 | 13 | 331.60 | 20 | 14.23 | 794 | 226 | 3.76 / 222.51 | 6 | 74 |
7 | 13 | 65.52 | 20 | 14.48 | 411 | 119 | 3.88 / 222.63 | 6 | 68 |
8 | 8 | 0.08 | 258 | 14.31 | 313 | 1156 | 5.04 / 223.79 | 6 | 131 |
Average= | 4.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.76 | 31 | 14.66 | 445 | 202 | 0.20 / 213.60 | 7 | 8 |
2 | 7 | 2005.20 | 40 | 12.84 | 2883 | 1481 | 1.68 / 215.08 | 6 | 46 |
3 | 13 | 1931.92 | 20 | 13.19 | 2812 | 742 | 2.42 / 215.82 | 6 | 56 |
4 | 13 | 1614.52 | 20 | 13.41 | 2439 | 654 | 3.08 / 216.48 | 6 | 67 |
5 | 13 | 1519.44 | 20 | 13.45 | 2309 | 621 | 3.70 / 217.10 | 6 | 69 |
6 | 13 | 645.72 | 20 | 14.01 | 1208 | 338 | 4.04 / 217.43 | 6 | 79 |
7 | 13 | 80.28 | 20 | 14.45 | 443 | 128 | 4.17 / 217.56 | 6 | 73 |
8 | 8 | 0.12 | 261 | 14.31 | 318 | 1188 | 5.35 / 218.75 | 6 | 130 |
Average= | 4.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.40 | 31 | 14.64 | 442 | 201 | 0.20 / 208.59 | 7 | 8 |
2 | 7 | 2008.80 | 40 | 12.84 | 2887 | 1483 | 1.68 / 210.07 | 8 | 46 |
3 | 13 | 1921.24 | 20 | 13.20 | 2787 | 736 | 2.42 / 210.80 | 6 | 57 |
4 | 13 | 1522.00 | 20 | 13.47 | 2316 | 624 | 3.04 / 211.43 | 6 | 70 |
5 | 13 | 989.12 | 20 | 13.80 | 1640 | 453 | 3.50 / 211.88 | 6 | 78 |
6 | 13 | 333.16 | 20 | 14.26 | 794 | 226 | 3.72 / 212.11 | 6 | 74 |
7 | 13 | 64.60 | 20 | 14.51 | 410 | 119 | 3.84 / 212.23 | 6 | 69 |
8 | 8 | 0.12 | 258 | 14.31 | 317 | 1170 | 5.01 / 213.40 | 6 | 131 |
Average= | 4.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.64 | 31 | 14.68 | 442 | 201 | 0.20 / 203.57 | 7 | 8 |
2 | 7 | 2006.44 | 40 | 12.90 | 2892 | 1492 | 1.69 / 205.06 | 6 | 46 |
3 | 13 | 1915.36 | 20 | 13.23 | 2797 | 740 | 2.43 / 205.80 | 6 | 56 |
4 | 13 | 1512.48 | 20 | 13.50 | 2310 | 624 | 3.06 / 206.42 | 6 | 70 |
5 | 13 | 883.80 | 20 | 13.87 | 1522 | 422 | 3.48 / 206.85 | 6 | 78 |
6 | 13 | 445.20 | 20 | 14.20 | 940 | 267 | 3.75 / 207.11 | 6 | 76 |
7 | 13 | 54.84 | 20 | 14.51 | 397 | 115 | 3.86 / 207.23 | 6 | 69 |
8 | 8 | 0.12 | 256 | 14.33 | 315 | 1156 | 5.02 / 208.38 | 6 | 130 |
Average= | 4.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.84 | 30 | 14.67 | 444 | 195 | 0.20 / 198.42 | 7 | 8 |
2 | 7 | 2003.24 | 40 | 12.93 | 2876 | 1487 | 1.68 / 199.91 | 6 | 47 |
3 | 13 | 1922.20 | 20 | 13.25 | 2783 | 737 | 2.42 / 200.65 | 6 | 57 |
4 | 13 | 1717.64 | 20 | 13.41 | 2564 | 688 | 3.11 / 201.34 | 6 | 65 |
5 | 13 | 1078.12 | 20 | 13.77 | 1762 | 485 | 3.59 / 201.82 | 6 | 78 |
6 | 13 | 417.00 | 20 | 14.22 | 908 | 258 | 3.85 / 202.08 | 6 | 76 |
7 | 13 | 88.60 | 20 | 14.49 | 447 | 130 | 3.98 / 202.21 | 6 | 71 |
8 | 8 | 0.04 | 258 | 14.33 | 313 | 1157 | 5.14 / 203.37 | 6 | 130 |
Average= | 4.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.24 | 30 | 14.70 | 445 | 196 | 0.20 / 193.39 | 7 | 8 |
2 | 7 | 2003.76 | 41 | 12.95 | 2875 | 1526 | 1.72 / 194.92 | 6 | 47 |
3 | 13 | 1919.24 | 20 | 13.25 | 2814 | 746 | 2.47 / 195.66 | 6 | 56 |
4 | 13 | 1605.24 | 20 | 13.48 | 2443 | 659 | 3.13 / 196.32 | 6 | 68 |
5 | 13 | 850.72 | 20 | 13.92 | 1474 | 410 | 3.54 / 196.73 | 6 | 79 |
6 | 13 | 318.32 | 20 | 14.32 | 770 | 221 | 3.76 / 196.95 | 6 | 75 |
7 | 13 | 54.20 | 20 | 14.57 | 394 | 115 | 3.87 / 197.07 | 6 | 67 |
8 | 8 | 0.04 | 256 | 14.35 | 316 | 1161 | 5.03 / 198.23 | 6 | 130 |
Average= | 4.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.52 | 30 | 14.70 | 432 | 191 | 0.19 / 188.22 | 7 | 7 |
2 | 7 | 2002.20 | 40 | 13.01 | 2878 | 1498 | 1.69 / 189.72 | 7 | 47 |
3 | 13 | 1916.28 | 20 | 13.29 | 2817 | 749 | 2.44 / 190.47 | 6 | 56 |
4 | 13 | 1604.68 | 20 | 13.50 | 2438 | 658 | 3.10 / 191.13 | 6 | 68 |
5 | 13 | 1172.52 | 20 | 13.75 | 1899 | 522 | 3.62 / 191.65 | 6 | 78 |
6 | 13 | 390.48 | 20 | 14.28 | 871 | 249 | 3.87 / 191.90 | 6 | 76 |
7 | 13 | 81.72 | 20 | 14.53 | 442 | 128 | 3.99 / 192.03 | 6 | 70 |
8 | 8 | 0.08 | 256 | 14.35 | 318 | 1168 | 5.16 / 193.20 | 6 | 129 |
Average= | 4.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.24 | 30 | 14.69 | 440 | 194 | 0.19 / 183.18 | 7 | 7 |
2 | 7 | 2003.08 | 40 | 13.01 | 2900 | 1509 | 1.70 / 184.69 | 7 | 46 |
3 | 13 | 1920.56 | 20 | 13.28 | 2836 | 753 | 2.46 / 185.45 | 6 | 57 |
4 | 13 | 1483.12 | 20 | 13.57 | 2285 | 620 | 3.08 / 186.07 | 6 | 70 |
5 | 13 | 950.56 | 20 | 13.90 | 1608 | 447 | 3.52 / 186.51 | 6 | 79 |
6 | 13 | 292.84 | 20 | 14.36 | 744 | 214 | 3.74 / 186.73 | 6 | 75 |
7 | 13 | 90.60 | 20 | 14.53 | 455 | 132 | 3.87 / 186.86 | 6 | 71 |
8 | 8 | 0.00 | 256 | 14.38 | 319 | 1174 | 5.04 / 188.03 | 6 | 131 |
Average= | 4.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.32 | 30 | 14.72 | 445 | 197 | 0.20 / 177.99 | 7 | 7 |
2 | 7 | 2002.92 | 41 | 13.03 | 2875 | 1536 | 1.73 / 179.53 | 7 | 47 |
3 | 13 | 1920.00 | 20 | 13.31 | 2810 | 748 | 2.48 / 180.28 | 6 | 57 |
4 | 13 | 1516.84 | 20 | 13.57 | 2332 | 633 | 3.11 / 180.91 | 6 | 71 |
5 | 13 | 1079.92 | 20 | 13.82 | 1785 | 493 | 3.61 / 181.40 | 6 | 78 |
6 | 13 | 486.36 | 20 | 14.24 | 1001 | 285 | 3.89 / 181.69 | 6 | 79 |
7 | 13 | 73.36 | 20 | 14.57 | 427 | 124 | 4.02 / 181.81 | 6 | 70 |
8 | 8 | 0.04 | 256 | 14.36 | 320 | 1176 | 5.19 / 182.99 | 6 | 130 |
Average= | 4.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.76 | 30 | 14.76 | 435 | 193 | 0.19 / 172.81 | 7 | 7 |
2 | 7 | 2009.72 | 40 | 13.09 | 2883 | 1510 | 1.70 / 174.32 | 7 | 47 |
3 | 13 | 1923.12 | 20 | 13.33 | 2807 | 748 | 2.45 / 175.06 | 6 | 57 |
4 | 13 | 1726.12 | 20 | 13.49 | 2592 | 699 | 3.15 / 175.76 | 6 | 65 |
5 | 13 | 1164.40 | 20 | 13.79 | 1884 | 520 | 3.67 / 176.28 | 6 | 77 |
6 | 13 | 274.56 | 20 | 14.40 | 722 | 208 | 3.88 / 176.49 | 6 | 73 |
7 | 13 | 85.00 | 20 | 14.58 | 441 | 129 | 4.01 / 176.62 | 6 | 68 |
8 | 8 | 0.08 | 258 | 14.39 | 317 | 1177 | 5.18 / 177.80 | 7 | 134 |
Average= | 4.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.32 | 30 | 14.73 | 435 | 192 | 0.19 / 167.72 | 7 | 7 |
2 | 7 | 2003.00 | 40 | 13.07 | 2890 | 1511 | 1.70 / 169.23 | 6 | 47 |
3 | 13 | 1923.16 | 20 | 13.33 | 2825 | 753 | 2.46 / 169.99 | 6 | 56 |
4 | 13 | 1512.28 | 20 | 13.60 | 2320 | 631 | 3.09 / 170.62 | 6 | 70 |
5 | 13 | 874.28 | 20 | 13.99 | 1505 | 421 | 3.51 / 171.04 | 6 | 78 |
6 | 13 | 421.72 | 20 | 14.30 | 923 | 264 | 3.77 / 171.30 | 6 | 76 |
7 | 13 | 91.64 | 20 | 14.59 | 449 | 131 | 3.90 / 171.43 | 6 | 68 |
8 | 8 | 0.12 | 258 | 14.37 | 318 | 1179 | 5.08 / 172.61 | 6 | 138 |
Average= | 4.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.96 | 30 | 14.76 | 431 | 191 | 0.19 / 162.66 | 7 | 8 |
2 | 7 | 2002.48 | 40 | 13.12 | 2864 | 1503 | 1.69 / 164.17 | 6 | 47 |
3 | 13 | 1918.60 | 20 | 13.34 | 2790 | 744 | 2.44 / 164.91 | 6 | 56 |
4 | 13 | 1614.76 | 20 | 13.58 | 2404 | 653 | 3.09 / 165.57 | 6 | 68 |
5 | 13 | 862.36 | 20 | 14.00 | 1481 | 415 | 3.51 / 165.98 | 6 | 77 |
6 | 13 | 419.76 | 20 | 14.32 | 908 | 260 | 3.77 / 166.24 | 6 | 76 |
7 | 13 | 96.20 | 20 | 14.58 | 461 | 134 | 3.90 / 166.37 | 6 | 69 |
8 | 8 | 0.08 | 256 | 14.39 | 314 | 1157 | 5.06 / 167.53 | 6 | 130 |
Average= | 4.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.40 | 30 | 14.76 | 444 | 197 | 0.20 / 157.55 | 7 | 7 |
2 | 7 | 2004.24 | 41 | 13.07 | 2864 | 1535 | 1.73 / 159.08 | 7 | 46 |
3 | 13 | 1921.28 | 20 | 13.35 | 2804 | 749 | 2.48 / 159.83 | 6 | 56 |
4 | 13 | 1516.56 | 20 | 13.62 | 2313 | 630 | 3.11 / 160.46 | 6 | 69 |
5 | 13 | 971.56 | 20 | 13.93 | 1633 | 455 | 3.57 / 160.92 | 6 | 78 |
6 | 13 | 409.24 | 20 | 14.32 | 904 | 259 | 3.82 / 161.18 | 6 | 76 |
7 | 13 | 89.40 | 20 | 14.59 | 447 | 130 | 3.95 / 161.31 | 6 | 69 |
8 | 8 | 0.12 | 256 | 14.38 | 317 | 1167 | 5.12 / 162.47 | 6 | 132 |
Average= | 4.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.64 | 30 | 14.74 | 432 | 191 | 0.19 / 152.43 | 7 | 8 |
2 | 7 | 2002.32 | 41 | 13.05 | 2878 | 1540 | 1.73 / 153.97 | 6 | 46 |
3 | 13 | 1914.00 | 20 | 13.32 | 2803 | 747 | 2.48 / 154.72 | 6 | 56 |
4 | 13 | 1599.84 | 20 | 13.55 | 2426 | 657 | 3.14 / 155.37 | 6 | 67 |
5 | 13 | 948.48 | 20 | 13.94 | 1615 | 450 | 3.59 / 155.82 | 6 | 77 |
6 | 13 | 291.88 | 20 | 14.42 | 743 | 214 | 3.80 / 156.04 | 6 | 73 |
7 | 13 | 94.88 | 20 | 14.59 | 456 | 133 | 3.93 / 156.17 | 6 | 66 |
8 | 8 | 0.32 | 259 | 14.39 | 317 | 1181 | 5.11 / 157.35 | 7 | 143 |
Average= | 4.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.04 | 30 | 14.73 | 426 | 188 | 0.19 / 147.44 | 7 | 8 |
2 | 7 | 2007.20 | 41 | 13.05 | 2882 | 1542 | 1.73 / 148.98 | 8 | 47 |
3 | 13 | 1915.04 | 20 | 13.32 | 2806 | 748 | 2.48 / 149.73 | 6 | 56 |
4 | 13 | 1507.20 | 20 | 13.59 | 2317 | 630 | 3.11 / 150.36 | 6 | 70 |
5 | 13 | 868.96 | 20 | 14.00 | 1507 | 422 | 3.53 / 150.78 | 6 | 76 |
6 | 13 | 235.80 | 20 | 14.47 | 665 | 192 | 3.72 / 150.97 | 6 | 72 |
7 | 13 | 72.88 | 20 | 14.63 | 419 | 123 | 3.84 / 151.10 | 6 | 65 |
8 | 8 | 0.12 | 251 | 14.40 | 316 | 1142 | 4.99 / 152.24 | 7 | 131 |
Average= | 4.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.64 | 30 | 14.69 | 449 | 198 | 0.20 / 142.37 | 7 | 9 |
2 | 7 | 2009.96 | 40 | 12.92 | 2895 | 1496 | 1.69 / 143.86 | 9 | 45 |
3 | 13 | 1932.96 | 20 | 13.25 | 2808 | 744 | 2.44 / 144.61 | 6 | 54 |
4 | 13 | 1611.88 | 20 | 13.51 | 2425 | 655 | 3.09 / 145.26 | 6 | 66 |
5 | 13 | 973.00 | 20 | 13.91 | 1639 | 456 | 3.55 / 145.72 | 6 | 77 |
6 | 13 | 339.20 | 20 | 14.37 | 811 | 233 | 3.78 / 145.95 | 6 | 73 |
7 | 13 | 67.96 | 20 | 14.64 | 412 | 121 | 3.90 / 146.07 | 6 | 63 |
8 | 8 | 0.00 | 261 | 14.39 | 314 | 1179 | 5.08 / 147.25 | 6 | 144 |
Average= | 4.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.84 | 30 | 14.72 | 438 | 193 | 0.19 / 137.41 | 7 | 8 |
2 | 7 | 2003.80 | 40 | 12.93 | 2892 | 1496 | 1.69 / 138.91 | 6 | 45 |
3 | 13 | 1923.32 | 20 | 13.25 | 2828 | 749 | 2.44 / 139.66 | 6 | 55 |
4 | 13 | 1522.32 | 20 | 13.55 | 2340 | 634 | 3.07 / 140.29 | 6 | 68 |
5 | 13 | 789.12 | 20 | 14.04 | 1398 | 393 | 3.47 / 140.68 | 6 | 76 |
6 | 13 | 256.36 | 20 | 14.45 | 696 | 201 | 3.67 / 140.88 | 6 | 72 |
7 | 13 | 81.48 | 20 | 14.61 | 438 | 128 | 3.79 / 141.01 | 6 | 66 |
8 | 8 | 0.08 | 254 | 14.39 | 317 | 1159 | 4.95 / 142.17 | 6 | 132 |
Average= | 4.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.16 | 30 | 14.72 | 441 | 195 | 0.19 / 132.40 | 7 | 8 |
2 | 7 | 2000.84 | 41 | 12.93 | 2870 | 1521 | 1.72 / 133.92 | 6 | 45 |
3 | 13 | 1915.40 | 20 | 13.25 | 2794 | 740 | 2.46 / 134.66 | 6 | 55 |
4 | 13 | 1503.04 | 20 | 13.56 | 2303 | 625 | 3.08 / 135.29 | 6 | 69 |
5 | 13 | 866.80 | 20 | 13.98 | 1511 | 422 | 3.50 / 135.71 | 6 | 76 |
6 | 13 | 326.64 | 20 | 14.40 | 793 | 228 | 3.73 / 135.94 | 6 | 73 |
7 | 13 | 62.52 | 20 | 14.66 | 402 | 118 | 3.85 / 136.06 | 6 | 64 |
8 | 8 | 0.32 | 256 | 14.39 | 315 | 1160 | 5.01 / 137.22 | 6 | 134 |
Average= | 4.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.56 | 30 | 14.71 | 452 | 199 | 0.20 / 127.25 | 7 | 8 |
2 | 7 | 2006.96 | 40 | 12.84 | 2895 | 1487 | 1.69 / 128.74 | 6 | 46 |
3 | 13 | 1916.32 | 20 | 13.23 | 2800 | 741 | 2.43 / 129.48 | 6 | 55 |
4 | 13 | 1607.08 | 20 | 13.48 | 2425 | 654 | 3.08 / 130.13 | 6 | 66 |
5 | 13 | 1052.04 | 20 | 13.83 | 1749 | 484 | 3.56 / 130.61 | 6 | 77 |
6 | 13 | 479.80 | 20 | 14.27 | 997 | 285 | 3.85 / 130.90 | 6 | 77 |
7 | 13 | 82.96 | 20 | 14.62 | 443 | 130 | 3.98 / 131.03 | 6 | 65 |
8 | 8 | 0.08 | 258 | 14.41 | 317 | 1179 | 5.16 / 132.21 | 7 | 131 |
Average= | 4.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.44 | 30 | 14.74 | 442 | 195 | 0.20 / 122.09 | 7 | 7 |
2 | 7 | 2011.16 | 40 | 12.87 | 2913 | 1500 | 1.70 / 123.59 | 6 | 46 |
3 | 13 | 1932.88 | 20 | 13.22 | 2823 | 746 | 2.44 / 124.34 | 6 | 54 |
4 | 13 | 1515.20 | 20 | 13.54 | 2322 | 629 | 3.07 / 124.97 | 6 | 67 |
5 | 13 | 1078.24 | 20 | 13.83 | 1778 | 492 | 3.56 / 125.46 | 6 | 76 |
6 | 13 | 407.16 | 20 | 14.34 | 901 | 258 | 3.82 / 125.72 | 6 | 74 |
7 | 13 | 96.16 | 20 | 14.61 | 465 | 136 | 3.96 / 125.86 | 6 | 66 |
8 | 8 | 0.16 | 261 | 14.42 | 317 | 1193 | 5.15 / 127.05 | 7 | 140 |
Average= | 4.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.92 | 30 | 14.75 | 433 | 192 | 0.19 / 116.98 | 7 | 7 |
2 | 7 | 2004.24 | 40 | 12.87 | 2880 | 1483 | 1.67 / 118.47 | 7 | 46 |
3 | 13 | 1921.84 | 20 | 13.22 | 2812 | 743 | 2.42 / 119.21 | 6 | 55 |
4 | 13 | 1596.56 | 20 | 13.49 | 2410 | 650 | 3.07 / 119.86 | 6 | 66 |
5 | 13 | 944.60 | 20 | 13.93 | 1602 | 446 | 3.51 / 120.31 | 6 | 78 |
6 | 13 | 395.32 | 20 | 14.35 | 883 | 253 | 3.77 / 120.56 | 6 | 74 |
7 | 13 | 85.76 | 20 | 14.63 | 446 | 130 | 3.90 / 120.69 | 6 | 67 |
8 | 13 | 45.40 | 20 | 14.62 | 385 | 113 | 4.01 / 120.80 | 6 | 64 |
9 | 13 | 24.92 | 20 | 14.62 | 353 | 103 | 4.11 / 120.91 | 6 | 62 |
10 | 8 | 0.08 | 218 | 14.41 | 316 | 993 | 5.11 / 121.90 | 7 | 141 |
Average= | 4.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.88 | 30 | 14.70 | 440 | 194 | 0.19 / 111.97 | 7 | 8 |
2 | 7 | 2006.40 | 41 | 12.91 | 2882 | 1525 | 1.72 / 113.50 | 6 | 46 |
3 | 13 | 1921.16 | 20 | 13.24 | 2813 | 745 | 2.46 / 114.24 | 6 | 55 |
4 | 13 | 1483.80 | 20 | 13.57 | 2293 | 622 | 3.09 / 114.86 | 6 | 70 |
5 | 13 | 952.44 | 20 | 13.92 | 1609 | 448 | 3.53 / 115.31 | 6 | 79 |
6 | 13 | 200.48 | 20 | 14.50 | 622 | 180 | 3.72 / 115.49 | 6 | 73 |
7 | 13 | 63.28 | 20 | 14.65 | 411 | 120 | 3.84 / 115.61 | 6 | 65 |
8 | 13 | 1.76 | 20 | 14.72 | 319 | 94 | 3.93 / 115.71 | 6 | 53 |
9 | 8 | 0.00 | 237 | 14.40 | 318 | 1085 | 5.01 / 116.79 | 7 | 135 |
Average= | 4.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.84 | 30 | 14.75 | 429 | 190 | 0.19 / 106.88 | 7 | 7 |
2 | 7 | 2007.92 | 41 | 12.96 | 2881 | 1531 | 1.72 / 108.41 | 7 | 47 |
3 | 13 | 1927.00 | 20 | 13.25 | 2813 | 745 | 2.47 / 109.15 | 6 | 55 |
4 | 13 | 1428.36 | 20 | 13.61 | 2221 | 605 | 3.07 / 109.76 | 6 | 71 |
5 | 13 | 1006.72 | 20 | 13.90 | 1683 | 468 | 3.54 / 110.22 | 6 | 77 |
6 | 13 | 357.76 | 20 | 14.41 | 826 | 238 | 3.78 / 110.46 | 6 | 74 |
7 | 13 | 67.72 | 20 | 14.65 | 425 | 125 | 3.90 / 110.59 | 6 | 68 |
8 | 13 | 34.04 | 20 | 14.64 | 372 | 109 | 4.01 / 110.70 | 6 | 66 |
9 | 8 | 0.12 | 235 | 14.40 | 320 | 1083 | 5.09 / 111.78 | 7 | 134 |
Average= | 4.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.32 | 30 | 14.76 | 446 | 197 | 0.20 / 101.81 | 7 | 7 |
2 | 7 | 2002.48 | 41 | 12.95 | 2877 | 1528 | 1.73 / 103.33 | 6 | 45 |
3 | 13 | 1921.72 | 20 | 13.28 | 2786 | 740 | 2.46 / 104.07 | 6 | 54 |
4 | 13 | 1419.20 | 20 | 13.63 | 2190 | 597 | 3.06 / 104.67 | 6 | 70 |
5 | 13 | 1003.00 | 20 | 13.92 | 1682 | 468 | 3.53 / 105.14 | 6 | 76 |
6 | 13 | 341.96 | 20 | 14.41 | 807 | 233 | 3.76 / 105.37 | 6 | 73 |
7 | 13 | 71.60 | 20 | 14.67 | 419 | 123 | 3.89 / 105.49 | 6 | 63 |
8 | 13 | 37.84 | 20 | 14.66 | 370 | 108 | 3.99 / 105.60 | 6 | 61 |
9 | 8 | 0.16 | 237 | 14.42 | 317 | 1083 | 5.08 / 106.69 | 6 | 141 |
Average= | 4.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.44 | 30 | 14.76 | 447 | 198 | 0.20 / 96.73 | 7 | 7 |
2 | 7 | 2007.80 | 41 | 13.02 | 2882 | 1538 | 1.74 / 98.26 | 7 | 45 |
3 | 13 | 1931.12 | 20 | 13.30 | 2822 | 751 | 2.49 / 99.02 | 6 | 54 |
4 | 13 | 1507.08 | 20 | 13.60 | 2301 | 626 | 3.11 / 99.64 | 6 | 67 |
5 | 13 | 966.24 | 20 | 13.95 | 1628 | 454 | 3.57 / 100.10 | 6 | 76 |
6 | 13 | 282.08 | 20 | 14.47 | 727 | 210 | 3.78 / 100.31 | 6 | 72 |
7 | 13 | 92.36 | 20 | 14.65 | 447 | 131 | 3.91 / 100.44 | 6 | 66 |
8 | 13 | 26.20 | 20 | 14.73 | 347 | 102 | 4.01 / 100.54 | 6 | 58 |
9 | 8 | 0.08 | 238 | 14.44 | 311 | 1069 | 5.08 / 101.61 | 7 | 139 |
Average= | 4.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.20 | 30 | 14.74 | 445 | 197 | 0.20 / 91.73 | 7 | 7 |
2 | 7 | 2008.08 | 40 | 13.04 | 2880 | 1502 | 1.70 / 93.24 | 6 | 46 |
3 | 13 | 1914.48 | 20 | 13.32 | 2764 | 736 | 2.44 / 93.97 | 6 | 54 |
4 | 13 | 1406.28 | 20 | 13.68 | 2152 | 589 | 3.02 / 94.56 | 6 | 70 |
5 | 13 | 986.60 | 20 | 13.95 | 1658 | 463 | 3.49 / 95.02 | 6 | 77 |
6 | 13 | 311.40 | 20 | 14.45 | 766 | 221 | 3.71 / 95.25 | 6 | 72 |
7 | 13 | 63.60 | 20 | 14.70 | 404 | 119 | 3.83 / 95.36 | 6 | 62 |
8 | 13 | 16.64 | 20 | 14.74 | 333 | 98 | 3.93 / 95.46 | 6 | 58 |
9 | 8 | 0.12 | 237 | 14.45 | 311 | 1065 | 4.99 / 96.53 | 7 | 134 |
Average= | 4.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.00 | 30 | 14.78 | 443 | 196 | 0.20 / 86.52 | 7 | 7 |
2 | 7 | 2007.52 | 41 | 13.07 | 2886 | 1547 | 1.74 / 88.07 | 7 | 47 |
3 | 13 | 1920.88 | 20 | 13.34 | 2807 | 749 | 2.49 / 88.82 | 6 | 56 |
4 | 13 | 1723.64 | 20 | 13.50 | 2568 | 693 | 3.19 / 89.51 | 6 | 63 |
5 | 13 | 1046.48 | 20 | 13.91 | 1737 | 483 | 3.67 / 89.99 | 6 | 77 |
6 | 13 | 345.48 | 20 | 14.43 | 808 | 233 | 3.90 / 90.23 | 6 | 74 |
7 | 13 | 67.12 | 20 | 14.70 | 414 | 122 | 4.02 / 90.35 | 6 | 65 |
8 | 13 | 15.20 | 20 | 14.73 | 338 | 100 | 4.12 / 90.45 | 6 | 62 |
9 | 8 | 0.04 | 237 | 14.40 | 319 | 1089 | 5.21 / 91.54 | 6 | 134 |
Average= | 4.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.84 | 30 | 14.80 | 441 | 196 | 0.20 / 81.36 | 7 | 7 |
2 | 7 | 2003.12 | 40 | 13.10 | 2884 | 1511 | 1.71 / 82.87 | 7 | 47 |
3 | 13 | 1909.84 | 20 | 13.35 | 2788 | 744 | 2.45 / 83.62 | 6 | 56 |
4 | 13 | 1585.60 | 20 | 13.59 | 2394 | 651 | 3.10 / 84.27 | 6 | 67 |
5 | 13 | 1035.00 | 20 | 13.92 | 1720 | 479 | 3.58 / 84.75 | 6 | 79 |
6 | 13 | 370.48 | 20 | 14.41 | 851 | 245 | 3.83 / 84.99 | 6 | 74 |
7 | 13 | 73.68 | 20 | 14.70 | 429 | 126 | 3.95 / 85.12 | 6 | 66 |
8 | 13 | 37.96 | 20 | 14.69 | 377 | 111 | 4.06 / 85.23 | 6 | 64 |
9 | 8 | 0.12 | 238 | 14.43 | 320 | 1099 | 5.16 / 86.33 | 6 | 133 |
Average= | 4.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.36 | 29 | 14.78 | 446 | 191 | 0.19 / 76.24 | 7 | 7 |
2 | 7 | 2003.04 | 40 | 13.11 | 2871 | 1506 | 1.70 / 77.74 | 6 | 47 |
3 | 13 | 1918.60 | 20 | 13.35 | 2826 | 755 | 2.45 / 78.50 | 6 | 56 |
4 | 13 | 1401.68 | 20 | 13.68 | 2180 | 596 | 3.05 / 79.09 | 6 | 71 |
5 | 13 | 965.56 | 20 | 13.98 | 1627 | 455 | 3.50 / 79.55 | 6 | 79 |
6 | 13 | 511.72 | 20 | 14.30 | 1037 | 297 | 3.80 / 79.84 | 6 | 76 |
7 | 13 | 86.00 | 20 | 14.69 | 445 | 131 | 3.93 / 79.97 | 6 | 65 |
8 | 13 | 45.72 | 20 | 14.71 | 381 | 112 | 4.04 / 80.09 | 6 | 62 |
9 | 8 | 0.08 | 237 | 14.48 | 314 | 1078 | 5.12 / 81.16 | 7 | 130 |
Average= | 4.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.52 | 29 | 14.81 | 443 | 190 | 0.19 / 71.26 | 7 | 7 |
2 | 7 | 2004.72 | 40 | 13.12 | 2876 | 1509 | 1.70 / 72.77 | 7 | 47 |
3 | 13 | 1907.40 | 20 | 13.37 | 2789 | 746 | 2.45 / 73.51 | 6 | 56 |
4 | 13 | 1392.12 | 20 | 13.71 | 2166 | 594 | 3.04 / 74.11 | 6 | 72 |
5 | 13 | 849.56 | 20 | 14.07 | 1479 | 416 | 3.46 / 74.52 | 6 | 77 |
6 | 13 | 285.72 | 20 | 14.50 | 728 | 211 | 3.67 / 74.74 | 6 | 73 |
7 | 13 | 92.32 | 20 | 14.70 | 451 | 133 | 3.80 / 74.87 | 6 | 66 |
8 | 13 | 51.08 | 20 | 14.72 | 388 | 114 | 3.91 / 74.98 | 6 | 61 |
9 | 8 | 0.08 | 237 | 14.50 | 309 | 1062 | 4.98 / 76.04 | 7 | 142 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.08 | 29 | 14.79 | 461 | 198 | 0.20 / 66.20 | 7 | 7 |
2 | 7 | 2002.20 | 40 | 13.15 | 2872 | 1511 | 1.71 / 67.71 | 7 | 47 |
3 | 13 | 1911.80 | 20 | 13.41 | 2787 | 747 | 2.46 / 68.46 | 6 | 56 |
4 | 13 | 1599.40 | 20 | 13.61 | 2408 | 655 | 3.11 / 69.12 | 6 | 67 |
5 | 13 | 950.76 | 20 | 13.99 | 1614 | 452 | 3.56 / 69.57 | 6 | 78 |
6 | 13 | 200.16 | 20 | 14.58 | 613 | 179 | 3.74 / 69.75 | 6 | 69 |
7 | 13 | 107.44 | 20 | 14.67 | 477 | 140 | 3.88 / 69.89 | 6 | 66 |
8 | 13 | 29.08 | 20 | 14.79 | 356 | 105 | 3.99 / 69.99 | 6 | 57 |
9 | 8 | 0.08 | 237 | 14.48 | 314 | 1078 | 5.06 / 71.07 | 7 | 136 |
Average= | 4.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.12 | 29 | 14.82 | 446 | 192 | 0.19 / 61.02 | 7 | 7 |
2 | 7 | 2011.36 | 41 | 13.14 | 2868 | 1545 | 1.74 / 62.57 | 7 | 47 |
3 | 13 | 1925.32 | 20 | 13.38 | 2808 | 751 | 2.49 / 63.32 | 6 | 56 |
4 | 13 | 1397.96 | 20 | 13.70 | 2193 | 601 | 3.09 / 63.92 | 6 | 72 |
5 | 13 | 976.04 | 20 | 13.97 | 1649 | 461 | 3.55 / 64.38 | 6 | 78 |
6 | 13 | 500.56 | 20 | 14.34 | 1017 | 292 | 3.84 / 64.67 | 6 | 76 |
7 | 13 | 79.36 | 20 | 14.74 | 437 | 129 | 3.97 / 64.80 | 6 | 64 |
8 | 13 | 23.24 | 20 | 14.80 | 354 | 105 | 4.08 / 64.91 | 6 | 58 |
9 | 8 | 0.08 | 237 | 14.48 | 320 | 1098 | 5.17 / 66.00 | 7 | 137 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.28 | 29 | 14.84 | 443 | 191 | 0.19 / 55.89 | 7 | 7 |
2 | 7 | 2002.44 | 41 | 13.17 | 2881 | 1556 | 1.75 / 57.44 | 7 | 47 |
3 | 13 | 1918.80 | 20 | 13.41 | 2824 | 757 | 2.50 / 58.20 | 6 | 56 |
4 | 13 | 1611.08 | 20 | 13.61 | 2438 | 664 | 3.17 / 58.86 | 6 | 66 |
5 | 13 | 853.68 | 20 | 14.07 | 1486 | 418 | 3.59 / 59.28 | 6 | 76 |
6 | 13 | 298.44 | 20 | 14.49 | 760 | 220 | 3.81 / 59.50 | 6 | 71 |
7 | 13 | 97.96 | 20 | 14.71 | 469 | 138 | 3.94 / 59.64 | 6 | 66 |
8 | 13 | 24.20 | 20 | 14.80 | 354 | 105 | 4.05 / 59.74 | 6 | 60 |
9 | 8 | 0.04 | 235 | 14.47 | 320 | 1088 | 5.14 / 60.83 | 6 | 133 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.84 | 29 | 14.81 | 452 | 194 | 0.19 / 50.67 | 7 | 8 |
2 | 7 | 2006.04 | 40 | 13.18 | 2877 | 1517 | 1.71 / 52.18 | 6 | 46 |
3 | 13 | 1820.12 | 20 | 13.50 | 2656 | 717 | 2.43 / 52.90 | 6 | 58 |
4 | 13 | 1729.36 | 20 | 13.54 | 2576 | 698 | 3.13 / 53.60 | 6 | 62 |
5 | 13 | 1158.68 | 20 | 13.87 | 1880 | 522 | 3.65 / 54.12 | 6 | 76 |
6 | 13 | 361.84 | 20 | 14.44 | 842 | 243 | 3.89 / 54.36 | 6 | 73 |
7 | 13 | 80.60 | 20 | 14.74 | 443 | 131 | 4.02 / 54.49 | 6 | 65 |
8 | 13 | 19.64 | 20 | 14.80 | 350 | 104 | 4.12 / 54.60 | 6 | 60 |
9 | 8 | 0.04 | 237 | 14.48 | 320 | 1098 | 5.22 / 55.69 | 6 | 139 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.12 | 29 | 14.82 | 454 | 195 | 0.20 / 45.57 | 7 | 7 |
2 | 7 | 2005.52 | 41 | 13.18 | 2877 | 1555 | 1.75 / 47.12 | 6 | 46 |
3 | 13 | 1913.80 | 20 | 13.44 | 2788 | 749 | 2.50 / 47.87 | 6 | 55 |
4 | 13 | 1385.56 | 20 | 13.74 | 2161 | 594 | 3.09 / 48.46 | 6 | 70 |
5 | 13 | 958.96 | 20 | 13.99 | 1630 | 456 | 3.55 / 48.92 | 6 | 76 |
6 | 13 | 289.16 | 20 | 14.51 | 741 | 215 | 3.76 / 49.13 | 6 | 71 |
7 | 13 | 90.96 | 20 | 14.72 | 463 | 136 | 3.90 / 49.27 | 6 | 67 |
8 | 13 | 20.40 | 20 | 14.79 | 351 | 104 | 4.00 / 49.37 | 6 | 62 |
9 | 8 | 0.04 | 235 | 14.46 | 323 | 1098 | 5.10 / 50.47 | 6 | 137 |
Average= | 4.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.08 | 29 | 14.85 | 440 | 189 | 0.19 / 40.51 | 7 | 8 |
2 | 7 | 2000.96 | 40 | 13.21 | 2887 | 1525 | 1.71 / 42.03 | 6 | 45 |
3 | 13 | 1910.24 | 20 | 13.44 | 2816 | 757 | 2.47 / 42.79 | 6 | 54 |
4 | 13 | 1495.04 | 20 | 13.68 | 2290 | 627 | 3.10 / 43.42 | 6 | 67 |
5 | 13 | 747.72 | 20 | 14.13 | 1356 | 383 | 3.48 / 43.80 | 6 | 74 |
6 | 13 | 312.04 | 20 | 14.49 | 782 | 227 | 3.71 / 44.03 | 6 | 72 |
7 | 13 | 97.28 | 20 | 14.71 | 474 | 139 | 3.85 / 44.17 | 6 | 68 |
8 | 13 | 22.44 | 20 | 14.79 | 359 | 106 | 3.95 / 44.27 | 6 | 62 |
9 | 8 | 0.12 | 235 | 14.46 | 323 | 1098 | 5.05 / 45.37 | 7 | 141 |
Average= | 4.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.48 | 29 | 14.86 | 430 | 185 | 0.19 / 35.43 | 7 | 8 |
2 | 7 | 2010.36 | 40 | 13.21 | 2897 | 1531 | 1.72 / 36.96 | 6 | 49 |
3 | 13 | 1923.00 | 20 | 13.41 | 2824 | 757 | 2.47 / 37.72 | 6 | 57 |
4 | 13 | 1505.44 | 20 | 13.66 | 2311 | 631 | 3.10 / 38.35 | 6 | 71 |
5 | 13 | 972.08 | 20 | 13.97 | 1646 | 460 | 3.56 / 38.81 | 6 | 80 |
6 | 13 | 211.84 | 20 | 14.60 | 634 | 185 | 3.75 / 39.00 | 6 | 74 |
7 | 13 | 64.84 | 20 | 14.77 | 420 | 124 | 3.87 / 39.12 | 6 | 67 |
8 | 13 | 34.00 | 20 | 14.74 | 376 | 111 | 3.98 / 39.23 | 6 | 65 |
9 | 8 | 0.16 | 232 | 14.45 | 324 | 1086 | 5.07 / 40.32 | 6 | 132 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.56 | 29 | 14.84 | 445 | 192 | 0.19 / 30.35 | 7 | 8 |
2 | 7 | 2009.28 | 40 | 13.19 | 2885 | 1522 | 1.71 / 31.87 | 6 | 50 |
3 | 13 | 1912.96 | 20 | 13.43 | 2767 | 743 | 2.46 / 32.62 | 6 | 59 |
4 | 13 | 1495.04 | 20 | 13.67 | 2294 | 627 | 3.08 / 33.24 | 6 | 71 |
5 | 13 | 1047.60 | 20 | 13.91 | 1745 | 485 | 3.57 / 33.73 | 6 | 79 |
6 | 13 | 252.88 | 20 | 14.55 | 697 | 203 | 3.77 / 33.93 | 6 | 75 |
7 | 13 | 79.04 | 20 | 14.75 | 447 | 132 | 3.90 / 34.06 | 6 | 70 |
8 | 8 | 0.16 | 254 | 14.48 | 322 | 1184 | 5.09 / 35.25 | 7 | 132 |
Average= | 3.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.20 | 28 | 14.85 | 444 | 185 | 0.18 / 25.24 | 7 | 8 |
2 | 3 | 1025.08 | 1 | 14.63 | 1697 | 25 | 0.21 / 25.26 | 6 | 16 |
3 | 7 | 2005.12 | 40 | 13.20 | 2872 | 1516 | 1.73 / 26.78 | 16 | 49 |
4 | 13 | 1913.04 | 20 | 13.39 | 2803 | 751 | 2.48 / 27.53 | 6 | 57 |
5 | 13 | 1601.32 | 20 | 13.59 | 2432 | 661 | 3.14 / 28.19 | 6 | 67 |
6 | 13 | 945.88 | 20 | 13.97 | 1612 | 450 | 3.59 / 28.64 | 6 | 79 |
7 | 13 | 281.92 | 20 | 14.52 | 736 | 214 | 3.80 / 28.85 | 6 | 74 |
8 | 13 | 50.52 | 20 | 14.78 | 405 | 120 | 3.92 / 28.97 | 6 | 67 |
9 | 8 | 0.12 | 251 | 14.44 | 327 | 1185 | 5.11 / 30.16 | 6 | 131 |
Average= | 3.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.72 | 28 | 14.91 | 377 | 157 | 0.16 / 20.47 | 7 | 8 |
2 | 7 | 2001.76 | 40 | 13.18 | 2875 | 1516 | 1.67 / 21.99 | 6 | 48 |
3 | 13 | 1913.20 | 20 | 13.39 | 2757 | 738 | 2.41 / 22.73 | 6 | 57 |
4 | 13 | 1494.12 | 20 | 13.65 | 2251 | 615 | 3.03 / 23.34 | 6 | 70 |
5 | 13 | 849.52 | 20 | 14.05 | 1440 | 405 | 3.43 / 23.75 | 6 | 79 |
6 | 13 | 202.76 | 20 | 14.61 | 579 | 169 | 3.60 / 23.92 | 6 | 74 |
7 | 13 | 55.72 | 20 | 14.80 | 362 | 107 | 3.71 / 24.02 | 6 | 68 |
8 | 8 | 0.12 | 249 | 14.50 | 285 | 1029 | 4.74 / 25.05 | 6 | 134 |
Average= | 3.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.28 | 31 | 14.86 | 391 | 180 | 0.18 / 15.81 | 7 | 7 |
2 | 3 | 840.28 | -2 | 14.86 | 391 | 0 | 0.00 / 15.81 | 7 | 7 |
3 | 7 | 2008.04 | 40 | 13.14 | 2872 | 1510 | 1.69 / 17.32 | 7 | 48 |
4 | 13 | 1925.12 | 20 | 13.34 | 2776 | 741 | 2.43 / 18.06 | 6 | 57 |
5 | 13 | 1512.04 | 20 | 13.60 | 2286 | 622 | 3.05 / 18.68 | 6 | 69 |
6 | 13 | 857.60 | 20 | 14.02 | 1448 | 406 | 3.46 / 19.08 | 6 | 77 |
7 | 13 | 189.32 | 20 | 14.62 | 553 | 162 | 3.62 / 19.25 | 6 | 73 |
8 | 13 | 52.28 | 20 | 14.80 | 348 | 103 | 3.72 / 19.35 | 6 | 67 |
9 | 8 | 0.04 | 249 | 14.51 | 268 | 968 | 4.69 / 20.32 | 6 | 134 |
Average= | 3.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.24 | 27 | 14.87 | 391 | 157 | 0.16 / 11.79 | 7 | 7 |
2 | 7 | 1511.12 | 41 | 13.56 | 2234 | 1242 | 1.40 / 13.03 | 7 | 43 |
3 | 13 | 1441.12 | 20 | 13.67 | 2189 | 598 | 2.00 / 13.63 | 6 | 52 |
4 | 13 | 1344.36 | 20 | 13.73 | 2065 | 567 | 2.56 / 14.20 | 6 | 57 |
5 | 13 | 472.60 | 20 | 14.36 | 935 | 269 | 2.83 / 14.47 | 6 | 69 |
6 | 13 | 81.12 | 20 | 14.78 | 391 | 116 | 2.95 / 14.58 | 6 | 63 |
7 | 13 | 42.40 | 20 | 14.77 | 333 | 98 | 3.05 / 14.68 | 6 | 61 |
8 | 8 | 0.04 | 244 | 14.49 | 267 | 944 | 3.99 / 15.63 | 6 | 140 |
Average= | 3.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.60 | 26 | 14.85 | 390 | 151 | 0.15 / 7.84 | 7 | 7 |
2 | 3 | 1039.32 | 1 | 14.54 | 1713 | 25 | 0.18 / 7.86 | 6 | 42 |
3 | 7 | 1515.84 | 41 | 13.49 | 2246 | 1242 | 1.42 / 9.10 | 42 | 44 |
4 | 13 | 1438.16 | 20 | 13.63 | 2171 | 592 | 2.01 / 9.70 | 6 | 52 |
5 | 13 | 1129.84 | 20 | 13.81 | 1796 | 496 | 2.51 / 10.19 | 6 | 61 |
6 | 13 | 585.32 | 20 | 14.21 | 1092 | 310 | 2.82 / 10.50 | 6 | 69 |
7 | 13 | 77.64 | 20 | 14.75 | 390 | 115 | 2.93 / 10.62 | 6 | 63 |
8 | 13 | 42.04 | 20 | 14.75 | 332 | 98 | 3.03 / 10.71 | 6 | 61 |
9 | 8 | 0.08 | 239 | 14.48 | 266 | 921 | 3.95 / 11.63 | 6 | 131 |
Average= | 2.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.48 | 31 | 14.73 | 388 | 177 | 0.18 / 3.96 | 7 | 8 |
2 | 3 | 833.04 | -3 | 14.73 | 388 | 0 | 0.00 / 3.96 | 7 | 8 |
3 | 7 | 1475.08 | 40 | 13.40 | 2180 | 1168 | 1.35 / 5.13 | 8 | 42 |
4 | 13 | 1411.16 | 20 | 13.55 | 2150 | 583 | 1.93 / 5.71 | 6 | 51 |
5 | 13 | 1209.60 | 20 | 13.71 | 1890 | 518 | 2.45 / 6.23 | 6 | 58 |
6 | 13 | 557.16 | 20 | 14.19 | 1045 | 297 | 2.74 / 6.53 | 6 | 68 |
7 | 13 | 107.24 | 20 | 14.65 | 437 | 128 | 2.87 / 6.66 | 6 | 67 |
8 | 13 | 30.28 | 20 | 14.76 | 311 | 92 | 2.96 / 6.75 | 6 | 60 |
9 | 8 | 0.08 | 245 | 14.44 | 265 | 938 | 3.90 / 7.69 | 6 | 140 |
Average= | 2.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.88 | 31 | 14.89 | 371 | 171 | 0.17 / 1.53 | 7 | 7 |
2 | 3 | 823.96 | -3 | 14.89 | 371 | 0 | 0.00 / 1.53 | 7 | 7 |
3 | 7 | 900.36 | 41 | 13.69 | 1475 | 828 | 1.00 / 2.35 | 7 | 46 |
4 | 13 | 589.80 | 20 | 14.09 | 1084 | 305 | 1.30 / 2.66 | 6 | 56 |
5 | 13 | 71.88 | 20 | 14.62 | 378 | 111 | 1.42 / 2.77 | 6 | 58 |
6 | 13 | 37.28 | 20 | 14.62 | 323 | 94 | 1.51 / 2.87 | 6 | 56 |
7 | 8 | 0.12 | 242 | 14.40 | 264 | 920 | 2.43 / 3.78 | 6 | 131 |
Average= | 1.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 88.04 | 30 | 14.68 | 342 | 151 | 0.15 / 0.15 | 7 | 7 |
2 | 7 | 95.72 | 41 | 14.63 | 340 | 204 | 0.35 / 0.35 | 7 | 7 |
3 | 13 | 73.36 | 20 | 14.87 | 318 | 95 | 0.45 / 0.45 | 7 | 7 |
4 | 13 | 45.52 | 20 | 14.91 | 280 | 83 | 0.53 / 0.53 | 7 | 8 |
5 | 8 | 0.28 | 261 | 14.80 | 213 | 823 | 1.36 / 1.36 | 7 | 135 |
Average= | 1.36 (KJ/cycle) |