SIO Argo Site:
Pump Diagnostics Page   



Serial= 3302 WMO= 1902622

Return

←PreviousNext→

Cycle 4 GMT 2/ 4/2025 20:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.60 30 15.12 389 176 0.18 / 11.01 2 2
2 7 1525.00 74 14.79 2102 2301 2.48 / 13.31 2 4
3 13 524.84 18 15.08 943 256 2.73 / 13.56 2 4
4 13 103.24 18 15.19 397 109 2.84 / 13.67 2 4
5 8 0.08 165 15.17 249 623 3.46 / 14.30 2 13
Average= 2.86
(KJ/cycle)

Cycle 3 GMT 1/ 4/2025 21: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.40 29 15.10 386 169 0.17 / 7.55 2 2
2 10 1008.08 2 15.18 1579 48 0.22 / 7.60 2 2
3 7 1528.80 74 14.80 2101 2301 2.52 / 9.90 2 3
4 13 401.12 18 15.10 799 217 2.74 / 10.12 2 4
5 13 81.12 18 15.19 363 99 2.83 / 10.22 2 4
6 8 0.16 165 15.17 245 613 3.45 / 10.83 2 8
Average= 2.71
(KJ/cycle)

Cycle 2 GMT 31/ 3/2025 21: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.52 31 15.15 385 181 0.18 / 4.11 2 2
2 3 967.96 -1 15.65 0 0 0.00 / 4.11 2 2
3 7 1528.48 75 14.80 2105 2337 2.52 / 6.45 2 4
4 13 377.56 18 15.11 766 208 2.73 / 6.66 2 4
5 13 105.12 18 15.19 396 108 2.83 / 6.77 2 4
6 8 0.04 165 15.17 246 616 3.45 / 7.38 2 11
Average= 2.46
(KJ/cycle)

Cycle 1 GMT 30/ 3/2025 21:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.88 26 15.36 348 139 0.14 / 1.46 3 3
2 10 1023.96 3 15.24 1596 73 0.21 / 1.54 2 2
3 3 1050.68 1 15.22 1582 24 0.24 / 1.56 2 2
4 7 1003.20 75 15.04 1479 1668 1.90 / 3.23 2 5
5 13 21.12 18 15.27 280 77 1.98 / 3.31 2 5
6 8 -0.16 165 15.22 250 628 2.61 / 3.93 2 9
Average= 1.97
(KJ/cycle)

Cycle 0 GMT 30/ 3/2025 10:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 127.64 25 15.56 355 138 0.14 / 0.14 3 3
2 7 144.28 74 15.51 391 449 0.59 / 0.59 3 3
3 8 0.20 240 15.44 199 737 1.32 / 1.32 3 13
Average= 1.32
(KJ/cycle)