SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.28 | 30 | 14.92 | 380 | 170 | 0.17 / 36.07 | 6 | 6 |
2 | 7 | 2007.28 | 40 | 14.50 | 2954 | 1713 | 1.88 / 37.78 | 6 | 6 |
3 | 13 | 1338.56 | 20 | 14.59 | 2093 | 611 | 2.49 / 38.40 | 5 | 8 |
4 | 13 | 772.36 | 20 | 14.70 | 1344 | 395 | 2.89 / 38.79 | 5 | 11 |
5 | 13 | 95.32 | 20 | 14.92 | 397 | 118 | 3.01 / 38.91 | 5 | 8 |
6 | 13 | 24.52 | 20 | 14.95 | 292 | 87 | 3.10 / 39.00 | 5 | 8 |
7 | 8 | 0.08 | 278 | 14.92 | 251 | 1041 | 4.14 / 40.04 | 5 | 139 |
Average= | 3.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.24 | 30 | 14.92 | 386 | 173 | 0.17 / 31.90 | 6 | 6 |
2 | 7 | 2005.04 | 40 | 14.51 | 2963 | 1720 | 1.89 / 33.62 | 6 | 6 |
3 | 13 | 1332.36 | 20 | 14.59 | 2090 | 610 | 2.50 / 34.23 | 5 | 8 |
4 | 13 | 768.88 | 20 | 14.70 | 1343 | 395 | 2.90 / 34.63 | 5 | 12 |
5 | 13 | 93.88 | 20 | 14.93 | 391 | 117 | 3.01 / 34.75 | 5 | 9 |
6 | 13 | 27.12 | 20 | 14.95 | 302 | 90 | 3.10 / 34.84 | 5 | 9 |
7 | 8 | 0.16 | 280 | 14.92 | 255 | 1065 | 4.17 / 35.90 | 5 | 214 |
Average= | 3.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.04 | 30 | 14.93 | 377 | 169 | 0.17 / 27.78 | 6 | 6 |
2 | 7 | 2009.88 | 40 | 14.52 | 2970 | 1725 | 1.89 / 29.50 | 6 | 6 |
3 | 13 | 1319.00 | 20 | 14.60 | 2081 | 608 | 2.50 / 30.11 | 5 | 8 |
4 | 13 | 742.44 | 20 | 14.71 | 1306 | 384 | 2.89 / 30.50 | 5 | 12 |
5 | 13 | 82.16 | 20 | 14.94 | 373 | 111 | 3.00 / 30.61 | 5 | 8 |
6 | 13 | 24.84 | 20 | 14.95 | 293 | 88 | 3.08 / 30.69 | 5 | 11 |
7 | 8 | 0.12 | 278 | 14.92 | 250 | 1037 | 4.12 / 31.73 | 5 | 207 |
Average= | 3.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.08 | 30 | 14.93 | 376 | 168 | 0.17 / 23.64 | 6 | 6 |
2 | 7 | 2010.60 | 40 | 14.52 | 2972 | 1726 | 1.89 / 25.37 | 6 | 6 |
3 | 13 | 1332.32 | 20 | 14.60 | 2087 | 609 | 2.50 / 25.98 | 5 | 8 |
4 | 13 | 763.60 | 20 | 14.71 | 1338 | 394 | 2.90 / 26.37 | 5 | 11 |
5 | 13 | 95.04 | 20 | 14.93 | 393 | 117 | 3.01 / 26.49 | 5 | 10 |
6 | 13 | 26.56 | 20 | 14.96 | 299 | 89 | 3.10 / 26.58 | 5 | 18 |
7 | 8 | -0.04 | 276 | 14.93 | 251 | 1034 | 4.14 / 27.61 | 5 | 167 |
Average= | 3.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.96 | 29 | 14.92 | 389 | 168 | 0.17 / 19.45 | 6 | 6 |
2 | 3 | 1031.48 | 1 | 14.89 | 1700 | 25 | 0.19 / 19.47 | 5 | 6 |
3 | 7 | 2006.64 | 40 | 14.52 | 2965 | 1722 | 1.92 / 21.20 | 6 | 6 |
4 | 13 | 1432.72 | 20 | 14.58 | 2234 | 651 | 2.57 / 21.85 | 5 | 8 |
5 | 13 | 739.44 | 20 | 14.72 | 1308 | 385 | 2.95 / 22.23 | 5 | 11 |
6 | 13 | 93.04 | 20 | 14.94 | 389 | 116 | 3.07 / 22.35 | 5 | 11 |
7 | 13 | 49.48 | 20 | 14.95 | 324 | 97 | 3.17 / 22.45 | 5 | 7 |
8 | 8 | 0.12 | 276 | 14.93 | 249 | 1026 | 4.19 / 23.47 | 5 | 155 |
Average= | 3.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.48 | 31 | 14.93 | 384 | 178 | 0.18 / 15.33 | 5 | 6 |
2 | 3 | 934.68 | -1 | 15.32 | 0 | 0 | 0.00 / 15.33 | 5 | 6 |
3 | 7 | 2011.28 | 40 | 14.53 | 2968 | 1725 | 1.90 / 17.05 | 6 | 6 |
4 | 13 | 1337.72 | 20 | 14.60 | 2082 | 608 | 2.51 / 17.66 | 5 | 8 |
5 | 13 | 764.12 | 20 | 14.72 | 1328 | 391 | 2.90 / 18.05 | 5 | 11 |
6 | 13 | 95.88 | 20 | 14.94 | 390 | 117 | 3.02 / 18.17 | 5 | 7 |
7 | 13 | 34.72 | 20 | 14.95 | 304 | 91 | 3.11 / 18.26 | 5 | 14 |
8 | 8 | 0.08 | 276 | 14.93 | 248 | 1022 | 4.13 / 19.28 | 5 | 131 |
Average= | 3.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.36 | 34 | 14.93 | 376 | 191 | 0.19 / 11.48 | 5 | 6 |
2 | 10 | 1023.64 | 6 | 14.82 | 1682 | 150 | 0.34 / 11.63 | 5 | 5 |
3 | 3 | 1033.20 | 1 | 14.87 | 1718 | 26 | 0.37 / 11.65 | 5 | 7 |
4 | 7 | 1520.60 | 40 | 14.69 | 2325 | 1366 | 1.73 / 13.02 | 7 | 7 |
5 | 13 | 1215.96 | 20 | 14.69 | 1926 | 566 | 2.30 / 13.59 | 5 | 9 |
6 | 13 | 650.72 | 20 | 14.78 | 1182 | 349 | 2.65 / 13.94 | 5 | 10 |
7 | 13 | 78.56 | 20 | 14.96 | 367 | 110 | 2.76 / 14.05 | 5 | 9 |
8 | 13 | 25.76 | 20 | 14.98 | 290 | 87 | 2.84 / 14.13 | 5 | 10 |
9 | 8 | 0.12 | 274 | 14.95 | 248 | 1016 | 3.86 / 15.15 | 5 | 164 |
Average= | 3.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.20 | 29 | 14.92 | 382 | 165 | 0.17 / 7.67 | 5 | 6 |
2 | 10 | 1001.56 | 5 | 14.82 | 1673 | 124 | 0.29 / 7.79 | 5 | 5 |
3 | 7 | 1517.12 | 40 | 14.69 | 2322 | 1364 | 1.65 / 9.16 | 5 | 6 |
4 | 13 | 1211.08 | 20 | 14.69 | 1925 | 566 | 2.22 / 9.72 | 5 | 8 |
5 | 13 | 636.32 | 20 | 14.79 | 1162 | 344 | 2.56 / 10.06 | 5 | 11 |
6 | 13 | 86.64 | 20 | 14.96 | 377 | 113 | 2.68 / 10.18 | 5 | 9 |
7 | 13 | 47.60 | 20 | 14.97 | 323 | 97 | 2.77 / 10.27 | 5 | 5 |
8 | 8 | 0.00 | 276 | 14.94 | 246 | 1014 | 3.79 / 11.29 | 5 | 172 |
Average= | 2.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.68 | 31 | 14.96 | 378 | 175 | 0.18 / 4.01 | 5 | 6 |
2 | 3 | 967.28 | -1 | 15.33 | 0 | 0 | 0.00 / 4.01 | 5 | 6 |
3 | 7 | 1520.04 | 40 | 14.69 | 2322 | 1364 | 1.54 / 5.37 | 6 | 6 |
4 | 13 | 1212.92 | 20 | 14.69 | 1935 | 569 | 2.11 / 5.94 | 5 | 8 |
5 | 13 | 644.16 | 20 | 14.78 | 1177 | 348 | 2.46 / 6.29 | 5 | 11 |
6 | 13 | 78.52 | 20 | 14.96 | 368 | 110 | 2.57 / 6.40 | 5 | 9 |
7 | 13 | 23.20 | 20 | 14.97 | 285 | 85 | 2.65 / 6.49 | 5 | 11 |
8 | 8 | 0.12 | 274 | 14.94 | 248 | 1015 | 3.67 / 7.50 | 5 | 143 |
Average= | 2.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.32 | 31 | 15.11 | 368 | 172 | 0.17 / 1.68 | 6 | 6 |
2 | 3 | 925.56 | -1 | 15.34 | 0 | 0 | 0.00 / 1.68 | 6 | 6 |
3 | 7 | 947.68 | 40 | 14.84 | 1568 | 931 | 1.10 / 2.61 | 6 | 9 |
4 | 13 | 97.76 | 20 | 15.03 | 391 | 118 | 1.22 / 2.72 | 5 | 8 |
5 | 13 | 29.64 | 20 | 15.04 | 295 | 89 | 1.31 / 2.81 | 5 | 14 |
6 | 8 | 0.16 | 278 | 15.00 | 245 | 1022 | 2.33 / 3.84 | 5 | 198 |
Average= | 1.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 153.88 | 30 | 15.29 | 423 | 194 | 0.19 / 0.19 | 6 | 6 |
2 | 7 | 166.20 | 41 | 15.26 | 434 | 272 | 0.47 / 0.47 | 6 | 6 |
3 | 13 | 83.20 | 20 | 15.25 | 318 | 97 | 0.56 / 0.56 | 6 | 6 |
4 | 8 | 0.08 | 302 | 15.21 | 205 | 942 | 1.50 / 1.50 | 6 | -99 |
Average= | 1.50 (KJ/cycle) |