SIO Argo Site:
Pump Diagnostics Page   



Serial= 7522 WMO= 1902516

Return

←PreviousNext→

Cycle 25 GMT 18/12/2024 5: 9: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.92 23 14.95 421 145 0.14 / 93.06 6 7
2 7 2005.64 40 14.35 3065 1759 1.90 / 94.82 7 20
3 13 1284.04 20 14.54 2104 612 2.52 / 95.43 6 27
4 13 680.20 20 14.73 1278 376 2.89 / 95.81 6 32
5 13 61.16 20 14.98 365 109 3.00 / 95.92 6 32
6 8 0.00 235 14.95 279 980 3.98 / 96.90 6 148
Average= 3.73
(KJ/cycle)

Cycle 24 GMT 7/12/2024 22:31:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.40 22 14.94 453 149 0.15 / 89.19 6 7
2 3 1035.40 1 14.86 1783 26 0.18 / 89.21 6 18
3 7 1953.56 40 14.36 2987 1716 1.89 / 90.93 18 21
4 13 1260.16 20 14.55 2062 600 2.49 / 91.53 6 29
5 13 560.92 20 14.78 1104 326 2.82 / 91.86 6 32
6 13 26.24 20 15.00 311 93 2.91 / 91.95 6 30
7 13 12.52 20 15.00 289 87 3.00 / 92.04 6 34
8 8 0.00 216 14.96 273 882 3.88 / 92.92 6 155
Average= 3.72
(KJ/cycle)

Cycle 23 GMT 27/11/2024 12:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.52 22 14.95 428 141 0.14 / 85.23 6 6
2 3 1026.32 1 14.89 1783 27 0.17 / 85.26 6 11
3 7 2005.80 40 14.36 3053 1754 1.92 / 87.01 11 18
4 13 1286.36 20 14.55 2097 610 2.53 / 87.62 6 28
5 13 580.08 20 14.78 1135 336 2.87 / 87.96 6 32
6 13 19.64 20 15.01 307 92 2.96 / 88.05 6 29
7 8 0.04 235 14.96 281 988 3.95 / 89.04 6 141
Average= 3.71
(KJ/cycle)

Cycle 22 GMT 17/11/2024 6: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.40 22 14.94 435 143 0.14 / 81.25 6 7
2 7 2005.28 40 14.36 3059 1757 1.90 / 83.01 7 19
3 13 1279.56 20 14.55 2100 611 2.51 / 83.62 6 29
4 13 697.52 20 14.73 1307 385 2.90 / 84.00 6 34
5 13 42.44 20 15.00 347 104 3.00 / 84.11 6 32
6 8 0.04 235 14.96 280 984 3.98 / 85.09 6 133
Average= 3.70
(KJ/cycle)

Cycle 21 GMT 6/11/2024 23:34: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.04 22 14.96 429 141 0.14 / 77.37 6 7
2 7 2004.84 40 14.36 3052 1753 1.89 / 79.12 7 18
3 13 1245.24 20 14.57 2044 596 2.49 / 79.71 6 26
4 13 530.16 20 14.81 1065 315 2.81 / 80.03 6 32
5 13 25.36 20 15.01 316 95 2.90 / 80.12 6 32
6 8 -0.04 233 14.97 282 984 3.88 / 81.11 6 143
Average= 3.69
(KJ/cycle)

Cycle 20 GMT 27/10/2024 17:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.80 23 14.95 432 149 0.15 / 73.36 6 8
2 3 952.52 -1 15.45 12 0 0.00 / 73.36 6 8
3 7 2005.56 40 14.36 3056 1755 1.90 / 75.12 8 20
4 13 1375.88 20 14.54 2224 647 2.55 / 75.76 6 27
5 13 647.28 20 14.76 1233 364 2.91 / 76.13 6 33
6 13 57.44 20 15.00 367 110 3.02 / 76.24 6 32
7 8 -0.04 235 14.97 280 985 4.01 / 77.22 6 134
Average= 3.68
(KJ/cycle)

Cycle 19 GMT 17/10/2024 11: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.44 22 14.96 450 148 0.15 / 69.37 6 7
2 10 1046.20 3 14.78 1770 78 0.23 / 69.45 6 15
3 3 952.24 -1 15.45 12 0 0.08 / 69.45 6 15
4 7 2009.80 41 14.35 3067 1804 2.03 / 71.25 15 19
5 13 1193.56 20 14.59 1979 577 2.61 / 71.83 6 28
6 13 501.76 20 14.82 1027 304 2.91 / 72.13 6 34
7 13 53.12 20 15.00 360 108 3.02 / 72.24 6 33
8 8 0.00 233 14.97 279 973 3.99 / 73.21 6 133
Average= 3.66
(KJ/cycle)

Cycle 18 GMT 7/10/2024 4:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.76 23 14.96 435 150 0.15 / 65.45 6 8
2 3 937.00 -1 15.46 12 0 0.00 / 65.45 6 8
3 7 2003.24 40 14.37 3058 1758 1.91 / 67.21 8 20
4 13 1260.44 20 14.58 2065 602 2.51 / 67.81 6 28
5 13 563.04 20 14.80 1114 330 2.84 / 68.14 6 32
6 13 22.48 20 15.03 309 93 2.93 / 68.23 6 29
7 8 0.12 235 14.98 280 986 3.92 / 69.22 6 151
Average= 3.64
(KJ/cycle)

Cycle 17 GMT 26/ 9/2024 22:22:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.40 22 14.96 444 146 0.15 / 61.53 6 8
2 3 1033.36 1 14.89 1772 26 0.17 / 61.56 6 16
3 7 2006.60 40 14.36 3068 1762 1.93 / 63.32 16 20
4 13 1278.68 20 14.57 2101 612 2.55 / 63.93 6 28
5 13 476.92 20 14.84 992 294 2.84 / 64.22 6 32
6 13 29.92 20 15.02 324 97 2.94 / 64.32 6 30
7 8 0.00 233 14.98 281 981 3.92 / 65.30 6 134
Average= 3.63
(KJ/cycle)

Cycle 16 GMT 16/ 9/2024 15:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.84 23 14.97 431 148 0.15 / 57.60 6 7
2 3 962.44 -1 15.47 12 0 0.00 / 57.60 6 7
3 7 2008.04 41 14.37 3064 1805 1.95 / 59.41 7 18
4 13 1173.60 20 14.61 1963 574 2.53 / 59.98 6 29
5 13 579.60 20 14.80 1133 335 2.86 / 60.32 6 34
6 13 40.36 20 15.02 333 100 2.96 / 60.42 6 32
7 8 0.04 234 14.98 276 967 3.93 / 61.38 6 139
Average= 3.61
(KJ/cycle)

Cycle 15 GMT 6/ 9/2024 9:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.32 23 14.96 451 155 0.16 / 53.69 6 8
2 7 2005.12 40 14.38 3066 1764 1.92 / 55.45 8 19
3 13 1261.68 20 14.58 2078 606 2.52 / 56.06 6 27
4 13 561.24 20 14.81 1113 330 2.85 / 56.39 6 32
5 13 37.32 20 15.03 331 99 2.95 / 56.49 6 31
6 8 0.00 233 14.99 277 967 3.92 / 57.45 6 152
Average= 3.59
(KJ/cycle)

Cycle 14 GMT 27/ 8/2024 3:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.08 22 14.97 454 150 0.15 / 49.64 6 7
2 3 1052.32 1 14.85 1792 27 0.18 / 49.66 6 18
3 7 2003.68 40 14.38 3063 1762 1.94 / 51.43 18 19
4 13 1296.12 20 14.57 2123 619 2.56 / 52.05 6 28
5 13 690.48 20 14.76 1293 382 2.94 / 52.43 6 35
6 13 37.16 20 15.03 336 101 3.04 / 52.53 6 30
7 8 0.04 235 14.98 285 1003 4.04 / 53.53 6 147
Average= 3.57
(KJ/cycle)

Cycle 13 GMT 16/ 8/2024 20:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.56 23 14.97 437 150 0.15 / 45.70 6 9
2 3 954.00 -1 15.48 12 0 0.00 / 45.70 6 9
3 7 2004.24 40 14.38 3072 1767 1.92 / 47.46 9 20
4 13 1197.12 20 14.61 1988 581 2.50 / 48.04 6 29
5 13 598.76 20 14.80 1164 345 2.84 / 48.39 6 35
6 13 48.32 20 15.03 356 107 2.95 / 48.50 6 32
7 8 0.00 234 14.99 283 993 3.94 / 49.49 6 135
Average= 3.53
(KJ/cycle)

Cycle 12 GMT 6/ 8/2024 14:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.32 22 14.98 458 151 0.15 / 41.71 6 8
2 3 1040.96 1 14.89 1803 27 0.18 / 41.73 6 19
3 7 2005.20 40 14.39 3068 1766 1.94 / 43.50 19 19
4 13 1204.60 20 14.62 1999 585 2.53 / 44.08 6 28
5 13 619.64 20 14.79 1194 353 2.88 / 44.44 6 33
6 13 52.80 20 15.02 364 109 2.99 / 44.55 6 31
7 8 0.12 235 14.99 284 1000 3.99 / 45.55 6 149
Average= 3.50
(KJ/cycle)

Cycle 11 GMT 27/ 7/2024 8: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.12 24 14.99 429 154 0.15 / 37.77 6 7
2 3 926.96 -1 15.49 12 0 0.00 / 37.77 6 7
3 7 2004.28 40 14.40 3062 1764 1.92 / 39.54 7 18
4 13 1260.44 20 14.60 2073 605 2.52 / 40.14 6 29
5 13 555.28 20 14.82 1103 327 2.85 / 40.47 6 35
6 13 75.12 20 15.02 388 117 2.97 / 40.58 6 32
7 8 0.00 231 15.00 280 970 3.94 / 41.55 6 130
Average= 3.46
(KJ/cycle)

Cycle 10 GMT 17/ 7/2024 1:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.76 22 14.99 448 148 0.15 / 33.72 6 7
2 3 1054.96 1 14.86 1819 27 0.17 / 33.75 6 20
3 7 2005.88 40 14.39 3071 1768 1.94 / 35.52 20 19
4 13 1366.36 20 14.56 2230 649 2.59 / 36.17 6 26
5 13 615.40 20 14.80 1190 352 2.94 / 36.52 6 34
6 13 24.16 20 15.05 319 96 3.04 / 36.61 6 30
7 8 0.00 234 15.00 286 1004 4.04 / 37.62 6 146
Average= 3.42
(KJ/cycle)

Cycle 9 GMT 6/ 7/2024 19:25: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.80 24 14.99 447 161 0.16 / 29.81 6 7
2 3 937.48 -1 15.49 12 0 0.00 / 29.81 6 7
3 7 2005.08 40 14.39 3075 1770 1.93 / 31.58 7 18
4 13 1200.28 20 14.62 2002 585 2.52 / 32.16 6 28
5 13 520.16 20 14.85 1060 315 2.83 / 32.48 6 33
6 13 38.24 20 15.04 340 102 2.93 / 32.58 6 28
7 8 0.00 233 15.00 285 996 3.93 / 33.57 6 143
Average= 3.36
(KJ/cycle)

Cycle 8 GMT 26/ 6/2024 12:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.40 24 15.00 456 164 0.16 / 25.80 6 7
2 7 2004.92 40 14.40 3075 1771 1.94 / 27.58 7 19
3 13 1267.56 20 14.60 2098 613 2.55 / 28.19 6 27
4 13 546.40 20 14.84 1101 327 2.87 / 28.52 6 33
5 13 39.00 20 15.04 349 105 2.98 / 28.62 6 31
6 8 0.04 233 15.00 293 1024 4.00 / 29.64 6 147
Average= 3.29
(KJ/cycle)

Cycle 7 GMT 16/ 6/2024 6:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.68 22 15.00 450 148 0.15 / 21.77 6 7
2 10 1029.24 3 14.84 1748 78 0.23 / 21.85 6 14
3 3 959.08 -1 15.49 12 0 0.08 / 21.85 6 14
4 7 2003.24 40 14.40 3066 1766 1.99 / 23.62 14 19
5 13 1184.60 20 14.63 1975 578 2.57 / 24.19 6 26
6 13 615.20 20 14.81 1187 352 2.92 / 24.55 6 32
7 13 21.88 20 15.05 313 94 3.02 / 24.64 6 29
8 8 0.04 233 15.01 286 1000 4.02 / 25.64 6 150
Average= 3.21
(KJ/cycle)

Cycle 6 GMT 5/ 6/2024 23:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 19 15.00 434 124 0.12 / 17.78 6 7
2 10 1042.88 3 14.82 1775 79 0.20 / 17.85 6 13
3 7 2008.16 41 14.41 3073 1816 2.02 / 19.67 13 18
4 13 1170.04 20 14.65 1965 576 2.59 / 20.25 6 28
5 13 469.60 20 14.87 988 294 2.89 / 20.54 6 33
6 13 23.56 20 15.06 320 96 2.98 / 20.64 6 31
7 8 0.04 231 15.01 285 988 3.97 / 21.62 6 135
Average= 3.09
(KJ/cycle)

Cycle 5 GMT 26/ 5/2024 17:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.44 31 15.01 452 210 0.21 / 13.89 6 7
2 3 674.72 -5 15.52 12 0 0.00 / 13.89 6 7
3 7 2008.80 40 14.43 3077 1776 1.99 / 15.66 7 17
4 13 1193.24 20 14.64 1989 582 2.57 / 16.25 6 27
5 13 591.72 20 14.83 1154 342 2.91 / 16.59 6 32
6 13 26.36 20 15.06 316 95 3.01 / 16.68 6 29
7 8 0.04 233 15.02 277 969 3.98 / 17.65 6 147
Average= 2.94
(KJ/cycle)

Cycle 4 GMT 16/ 5/2024 10:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.20 23 15.01 436 151 0.15 / 10.46 6 6
2 7 1521.16 40 14.63 2410 1410 1.56 / 11.87 6 19
3 13 1082.40 20 14.73 1826 538 2.10 / 12.41 6 26
4 13 370.48 20 14.95 831 248 2.35 / 12.66 6 29
5 13 24.00 20 15.09 306 92 2.44 / 12.75 6 29
6 8 0.04 227 15.04 272 929 3.37 / 13.68 6 143
Average= 2.74
(KJ/cycle)

Cycle 3 GMT 15/ 5/2024 0:56: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.48 18 15.03 423 114 0.11 / 6.97 6 6
2 10 1026.24 5 14.84 1743 129 0.24 / 7.10 6 9
3 7 1506.60 40 14.64 2394 1402 1.65 / 8.50 9 18
4 13 1082.00 20 14.72 1823 537 2.18 / 9.04 6 24
5 13 378.20 20 14.95 839 251 2.43 / 9.29 6 30
6 13 23.80 20 15.08 312 94 2.53 / 9.38 6 27
7 8 0.08 227 15.04 271 925 3.45 / 10.31 6 133
Average= 2.58
(KJ/cycle)

Cycle 2 GMT 13/ 5/2024 15:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.56 31 15.07 429 200 0.20 / 3.67 6 7
2 3 654.32 -5 15.54 12 0 0.00 / 3.67 6 7
3 7 1436.04 40 14.69 2293 1347 1.55 / 5.01 7 17
4 13 1209.44 20 14.71 2005 590 2.14 / 5.60 6 23
5 13 338.48 20 14.97 782 234 2.37 / 5.84 6 30
6 13 19.00 20 15.09 307 93 2.46 / 5.93 6 32
7 8 0.08 225 15.05 273 924 3.39 / 6.86 6 136
Average= 2.29
(KJ/cycle)

Cycle 1 GMT 12/ 5/2024 5:35:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.68 31 15.22 424 200 0.20 / 1.62 6 6
2 3 711.56 -4 15.54 12 0 0.00 / 1.62 6 6
3 7 763.20 40 14.93 1380 824 1.02 / 2.45 6 25
4 13 24.84 20 15.17 305 93 1.12 / 2.54 6 23
5 8 0.12 227 15.12 270 927 2.04 / 3.47 6 153
Average= 1.73
(KJ/cycle)

Cycle 0 GMT 11/ 5/2024 19:52: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.00 30 15.38 428 197 0.20 / 0.20 6 9
2 7 120.96 40 15.36 443 272 0.47 / 0.47 9 10
3 13 20.76 20 15.36 287 88 0.56 / 0.56 6 15
4 8 0.12 220 15.31 257 866 1.42 / 1.42 6 143
Average= 1.42
(KJ/cycle)