SIO Argo Site:
Pump Diagnostics Page   



Serial= 7713 WMO= 1902508

Return

←PreviousNext→

Cycle 39 GMT 3/ 4/2025 22:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.52 29 15.06 450 197 0.20 / 166.84 6 6
2 7 2010.56 41 14.74 2826 1708 1.90 / 168.54 6 7
3 13 1322.12 20 14.83 2002 594 2.50 / 169.14 5 10
4 13 622.16 20 15.01 1110 333 2.83 / 169.47 5 10
5 13 15.72 20 15.17 331 100 2.93 / 169.57 6 10
6 8 -0.12 329 15.10 298 1480 4.41 / 171.05 6 134
Average= 4.28
(KJ/cycle)

Cycle 38 GMT 24/ 3/2025 15:50: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.56 29 15.07 441 193 0.19 / 162.49 6 6
2 7 2009.96 40 14.75 2816 1661 1.85 / 164.15 6 7
3 13 1306.96 20 14.84 1979 587 2.44 / 164.74 5 10
4 13 621.12 20 15.01 1109 333 2.77 / 165.07 5 10
5 8 0.24 351 15.11 296 1570 4.34 / 166.64 6 150
Average= 4.27
(KJ/cycle)

Cycle 37 GMT 14/ 3/2025 9:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.84 29 15.07 446 195 0.19 / 158.06 6 6
2 7 2005.92 40 14.74 2828 1667 1.86 / 159.72 6 7
3 13 1432.76 20 14.81 2144 635 2.50 / 160.36 5 10
4 13 615.28 20 15.01 1113 334 2.83 / 160.69 5 10
5 13 15.32 20 15.18 325 99 2.93 / 160.79 6 9
6 8 0.04 329 15.10 303 1505 4.44 / 162.30 6 142
Average= 4.27
(KJ/cycle)

Cycle 36 GMT 4/ 3/2025 2:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.88 28 15.08 453 191 0.19 / 153.66 6 6
2 7 2005.40 40 14.75 2824 1666 1.86 / 155.32 6 7
3 13 1414.36 20 14.82 2125 630 2.49 / 155.95 5 10
4 13 687.52 20 15.00 1203 361 2.85 / 156.31 5 11
5 8 0.28 349 15.12 293 1546 4.39 / 157.86 6 142
Average= 4.27
(KJ/cycle)

Cycle 35 GMT 21/ 2/2025 20: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.88 28 15.08 447 189 0.19 / 149.23 6 6
2 7 2003.24 40 14.76 2827 1669 1.86 / 150.90 6 8
3 13 1309.68 20 14.85 1995 593 2.45 / 151.49 5 10
4 13 642.32 20 15.02 1151 346 2.80 / 151.84 5 10
5 13 145.20 20 15.15 495 150 2.95 / 151.99 6 9
6 8 0.12 327 15.12 299 1478 4.42 / 153.47 6 132
Average= 4.26
(KJ/cycle)

Cycle 34 GMT 11/ 2/2025 13:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.40 28 15.08 452 191 0.19 / 144.82 6 6
2 7 2008.36 40 14.76 2826 1668 1.86 / 146.49 6 8
3 13 1252.32 20 14.86 1924 572 2.43 / 147.06 5 11
4 13 686.80 20 15.00 1205 361 2.79 / 147.42 5 11
5 13 42.08 20 15.18 364 111 2.90 / 147.53 6 8
6 8 0.04 329 15.12 303 1507 4.41 / 149.04 6 130
Average= 4.26
(KJ/cycle)

Cycle 33 GMT 1/ 2/2025 7: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.64 28 15.09 445 188 0.19 / 140.37 6 6
2 7 2011.04 40 14.75 2833 1671 1.86 / 142.04 6 7
3 13 1298.00 20 14.86 1984 590 2.45 / 142.63 5 11
4 13 695.28 20 15.00 1214 364 2.81 / 142.99 5 12
5 13 28.00 20 15.19 338 103 2.92 / 143.09 6 10
6 8 -0.04 327 15.12 311 1538 4.45 / 144.63 6 135
Average= 4.25
(KJ/cycle)

Cycle 32 GMT 22/ 1/2025 0:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.04 28 15.10 458 194 0.19 / 135.99 6 6
2 7 2005.04 40 14.77 2830 1672 1.87 / 137.66 6 8
3 13 1207.36 20 14.88 1872 557 2.42 / 138.21 5 11
4 13 638.96 20 15.03 1145 344 2.77 / 138.56 5 11
5 13 72.72 20 15.18 398 121 2.89 / 138.68 6 10
6 8 0.16 325 15.12 305 1499 4.39 / 140.18 6 133
Average= 4.25
(KJ/cycle)

Cycle 31 GMT 11/ 1/2025 17:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.84 27 15.11 443 181 0.18 / 131.54 6 6
2 7 2010.20 40 14.78 2811 1662 1.84 / 133.20 6 8
3 13 1335.64 20 14.86 2021 601 2.44 / 133.81 5 10
4 13 733.56 20 15.00 1256 377 2.82 / 134.18 5 11
5 13 55.36 20 15.19 376 114 2.93 / 134.30 6 8
6 8 1.88 325 15.13 304 1495 4.43 / 135.79 6 132
Average= 4.24
(KJ/cycle)

Cycle 30 GMT 1/ 1/2025 11:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.40 27 15.09 464 189 0.19 / 127.14 6 6
2 7 2010.60 40 14.76 2823 1667 1.86 / 128.81 6 7
3 13 1408.08 20 14.84 2099 623 2.48 / 129.43 5 10
4 13 647.20 20 15.04 1137 342 2.82 / 129.77 5 13
5 13 72.72 20 15.19 388 118 2.94 / 129.89 6 11
6 8 0.00 325 15.14 299 1471 4.41 / 131.36 6 148
Average= 4.24
(KJ/cycle)

Cycle 29 GMT 22/12/2024 5: 6: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.96 27 15.10 440 179 0.18 / 122.76 6 6
2 7 2004.28 40 14.77 2829 1671 1.85 / 124.43 6 7
3 13 1219.60 20 14.89 1883 561 2.41 / 124.99 5 10
4 13 653.28 20 15.02 1167 351 2.76 / 125.34 5 12
5 13 33.64 20 15.20 358 109 2.87 / 125.45 6 7
6 8 0.28 323 15.13 307 1500 4.37 / 126.95 6 132
Average= 4.23
(KJ/cycle)

Cycle 28 GMT 11/12/2024 22:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.12 27 15.11 450 184 0.18 / 118.37 6 6
2 7 2003.76 40 14.78 2807 1659 1.84 / 120.03 6 8
3 13 1290.56 20 14.88 1954 582 2.42 / 120.61 5 11
4 13 702.36 20 15.02 1221 367 2.79 / 120.98 5 12
5 13 48.00 20 15.20 362 110 2.90 / 121.09 6 8
6 8 0.20 323 15.14 305 1492 4.39 / 122.58 6 137
Average= 4.23
(KJ/cycle)

Cycle 27 GMT 1/12/2024 16:15:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.48 28 15.11 434 184 0.18 / 113.90 6 6
2 7 2014.16 40 14.78 2833 1675 1.86 / 115.58 6 7
3 13 1308.92 20 14.87 1996 594 2.45 / 116.17 5 10
4 13 711.68 20 15.01 1250 375 2.83 / 116.54 5 11
5 13 52.12 20 15.20 375 114 2.94 / 116.66 6 8
6 8 0.20 325 15.14 311 1530 4.47 / 118.19 6 146
Average= 4.22
(KJ/cycle)

Cycle 26 GMT 21/11/2024 9:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.60 28 15.12 437 185 0.19 / 109.39 6 6
2 7 2010.76 41 14.79 2824 1712 1.90 / 111.10 6 7
3 13 1398.24 20 14.87 2108 627 2.52 / 111.73 5 10
4 13 663.24 20 15.04 1179 355 2.88 / 112.08 5 11
5 13 70.44 20 15.20 402 122 3.00 / 112.21 6 10
6 8 0.00 323 15.14 309 1511 4.51 / 113.72 6 149
Average= 4.21
(KJ/cycle)

Cycle 25 GMT 11/11/2024 3:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.52 27 15.13 434 177 0.18 / 104.91 6 6
2 7 2011.88 41 14.79 2814 1706 1.88 / 106.61 6 7
3 13 1313.36 20 14.89 1986 591 2.48 / 107.20 5 9
4 13 696.20 20 15.04 1214 365 2.84 / 107.57 5 10
5 13 58.80 20 15.21 386 117 2.96 / 107.69 6 11
6 8 0.24 321 15.15 312 1517 4.48 / 109.20 6 149
Average= 4.20
(KJ/cycle)

Cycle 24 GMT 31/10/2024 20:59: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.88 27 15.14 438 179 0.18 / 100.52 6 6
2 7 2011.48 40 14.80 2816 1667 1.85 / 102.19 6 6
3 13 1296.04 20 14.91 1965 586 2.43 / 102.77 5 9
4 13 614.96 20 15.07 1113 335 2.77 / 103.11 5 9
5 13 53.96 20 15.21 383 117 2.88 / 103.23 6 15
6 8 -0.08 321 15.16 309 1504 4.39 / 104.73 6 146
Average= 4.19
(KJ/cycle)

Cycle 23 GMT 21/10/2024 14:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.68 26 15.14 449 177 0.18 / 96.08 6 6
2 10 1017.72 3 15.15 1587 72 0.25 / 96.15 6 6
3 3 946.92 -1 15.49 7 0 0.07 / 96.15 6 6
4 7 2013.64 40 14.80 2823 1671 1.92 / 97.82 6 7
5 13 1219.08 20 14.92 1879 561 2.48 / 98.38 5 10
6 13 635.60 20 15.06 1145 345 2.83 / 98.73 5 10
7 13 40.68 20 15.22 365 111 2.94 / 98.84 6 13
8 8 0.32 321 15.16 309 1504 4.44 / 100.34 6 144
Average= 4.18
(KJ/cycle)

Cycle 22 GMT 11/10/2024 7:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.16 27 15.14 420 172 0.17 / 91.70 6 6
2 7 2005.36 41 14.80 2815 1708 1.88 / 93.40 6 7
3 13 1288.84 20 14.91 1966 586 2.47 / 93.99 5 11
4 13 568.72 20 15.09 1047 316 2.78 / 94.31 5 11
5 13 50.08 20 15.22 378 115 2.90 / 94.42 6 12
6 8 0.08 319 15.16 306 1480 4.38 / 95.90 6 144
Average= 4.17
(KJ/cycle)

Cycle 21 GMT 1/10/2024 1:31:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.92 27 15.15 425 174 0.17 / 87.34 6 6
2 7 2006.88 40 14.81 2834 1679 1.85 / 89.02 6 7
3 13 1194.92 20 14.94 1854 554 2.41 / 89.57 5 10
4 13 621.36 20 15.08 1125 339 2.75 / 89.91 5 11
5 13 35.88 20 15.23 364 111 2.86 / 90.02 6 7
6 8 0.04 319 15.16 310 1499 4.36 / 91.52 6 138
Average= 4.16
(KJ/cycle)

Cycle 20 GMT 20/ 9/2024 19: 2:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.00 27 15.16 437 179 0.18 / 82.92 6 6
2 7 2010.48 40 14.81 2841 1683 1.86 / 84.61 6 7
3 13 1198.36 20 14.93 1866 557 2.42 / 85.16 5 10
4 13 719.00 20 15.05 1257 378 2.80 / 85.54 5 12
5 13 47.32 20 15.23 382 116 2.91 / 85.66 6 6
6 8 -0.12 319 15.17 312 1510 4.42 / 87.17 6 141
Average= 4.15
(KJ/cycle)

Cycle 19 GMT 10/ 9/2024 12:34:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.16 27 15.15 446 182 0.18 / 78.47 6 6
2 7 2010.84 40 14.80 2848 1686 1.87 / 80.16 6 7
3 13 1311.08 20 14.91 2011 600 2.47 / 80.76 5 11
4 13 604.28 20 15.09 1116 337 2.80 / 81.09 5 11
5 13 43.88 20 15.24 378 115 2.92 / 81.21 6 14
6 8 0.16 319 15.18 317 1535 4.46 / 82.74 6 142
Average= 4.14
(KJ/cycle)

Cycle 18 GMT 31/ 8/2024 6: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.92 27 15.16 457 187 0.19 / 74.01 6 6
2 7 2009.16 40 14.81 2824 1673 1.86 / 75.68 6 7
3 13 1315.56 20 14.91 1991 594 2.45 / 76.27 5 10
4 13 711.48 20 15.05 1248 376 2.83 / 76.65 5 11
5 13 31.44 20 15.24 362 110 2.94 / 76.76 6 7
6 8 0.08 317 15.17 318 1529 4.47 / 78.29 6 141
Average= 4.12
(KJ/cycle)

Cycle 17 GMT 20/ 8/2024 23:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.40 27 15.16 454 186 0.19 / 69.49 6 6
2 7 2010.00 40 14.81 2849 1688 1.87 / 71.17 6 7
3 13 1403.04 20 14.89 2122 632 2.51 / 71.81 5 10
4 13 656.28 20 15.08 1182 356 2.86 / 72.16 5 11
5 13 41.60 20 15.24 377 115 2.98 / 72.28 5 14
6 8 0.16 317 15.17 321 1544 4.52 / 73.82 6 131
Average= 4.10
(KJ/cycle)

Cycle 16 GMT 10/ 8/2024 17:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.28 27 15.16 444 182 0.18 / 65.04 6 6
2 7 2006.64 40 14.80 2834 1678 1.86 / 66.72 6 7
3 13 1398.28 20 14.89 2130 634 2.49 / 67.35 5 11
4 13 562.68 20 15.11 1060 320 2.81 / 67.67 5 11
5 13 46.56 20 15.24 383 117 2.93 / 67.79 6 11
6 8 0.12 317 15.18 314 1511 4.44 / 69.30 6 131
Average= 4.08
(KJ/cycle)

Cycle 15 GMT 31/ 7/2024 10:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.20 30 15.16 451 205 0.21 / 60.56 6 6
2 3 896.84 -2 15.53 7 0 0.00 / 60.56 6 6
3 7 2007.44 40 14.82 2843 1685 1.89 / 62.24 6 7
4 13 1213.24 20 14.94 1896 567 2.46 / 62.81 5 11
5 13 730.16 20 15.05 1283 386 2.84 / 63.19 5 11
6 13 40.16 20 15.24 378 115 2.96 / 63.31 6 14
7 8 0.12 319 15.18 320 1550 4.51 / 64.86 6 129
Average= 4.05
(KJ/cycle)

Cycle 14 GMT 21/ 7/2024 4:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.36 27 15.17 450 184 0.18 / 56.10 6 6
2 3 1031.80 1 15.23 1650 25 0.21 / 56.12 5 6
3 7 2006.52 40 14.82 2818 1671 1.88 / 57.79 6 8
4 13 1187.72 20 14.97 1844 552 2.43 / 58.35 5 11
5 13 603.92 20 15.11 1106 334 2.77 / 58.68 5 11
6 13 27.92 20 15.26 358 109 2.88 / 58.79 6 15
7 8 0.00 319 15.19 322 1560 4.44 / 60.35 6 130
Average= 4.02
(KJ/cycle)

Cycle 13 GMT 10/ 7/2024 22: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.36 26 15.17 469 185 0.18 / 51.71 6 6
2 7 2005.32 40 14.82 2838 1682 1.87 / 53.39 6 7
3 13 1186.16 20 14.97 1850 554 2.42 / 53.94 5 11
4 13 583.72 20 15.12 1085 328 2.75 / 54.27 5 11
5 13 24.52 20 15.26 350 107 2.86 / 54.38 6 20
6 8 0.16 321 15.19 315 1536 4.39 / 55.91 6 149
Average= 3.99
(KJ/cycle)

Cycle 12 GMT 30/ 6/2024 15:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.32 26 15.17 468 185 0.18 / 47.31 6 6
2 7 2004.52 40 14.84 2833 1682 1.87 / 48.99 6 8
3 13 1173.56 20 14.98 1836 550 2.42 / 49.54 5 11
4 13 603.48 20 15.12 1110 336 2.75 / 49.88 5 11
5 13 22.32 20 15.27 347 106 2.86 / 49.99 6 12
6 8 0.08 319 15.20 317 1537 4.40 / 51.52 6 133
Average= 3.96
(KJ/cycle)

Cycle 11 GMT 20/ 6/2024 9: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.24 26 15.17 475 187 0.19 / 42.79 6 6
2 3 1022.16 1 15.26 1604 24 0.21 / 42.82 5 6
3 7 2008.12 40 14.84 2828 1679 1.89 / 44.50 6 7
4 13 1310.88 20 14.95 2001 598 2.49 / 45.10 5 11
5 13 598.56 20 15.12 1101 333 2.82 / 45.43 5 11
6 13 21.68 20 15.27 354 108 2.93 / 45.54 6 12
7 8 0.12 321 15.20 326 1591 4.52 / 47.13 6 135
Average= 3.93
(KJ/cycle)

Cycle 10 GMT 10/ 6/2024 2:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.84 26 15.17 486 192 0.19 / 38.36 6 6
2 7 2012.16 41 14.83 2840 1727 1.92 / 40.09 6 8
3 13 1087.24 20 15.01 1730 519 2.44 / 40.61 5 11
4 13 534.40 20 15.14 1026 311 2.75 / 40.92 5 11
5 13 30.80 20 15.27 370 113 2.86 / 41.03 6 12
6 8 0.12 319 15.20 325 1576 4.44 / 42.61 6 129
Average= 3.87
(KJ/cycle)

Cycle 9 GMT 30/ 5/2024 19:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.84 25 15.18 479 182 0.18 / 33.80 6 6
2 7 2002.48 40 14.84 2828 1679 1.86 / 35.48 6 8
3 13 1285.04 20 14.96 1980 592 2.45 / 36.07 5 11
4 13 666.76 20 15.11 1192 360 2.81 / 36.43 5 11
5 13 30.92 20 15.27 374 114 2.93 / 36.54 6 16
6 8 0.16 322 15.20 332 1625 4.55 / 38.17 6 143
Average= 3.82
(KJ/cycle)

Cycle 8 GMT 20/ 5/2024 13:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.44 25 15.19 472 179 0.18 / 29.23 6 6
2 3 1018.56 1 15.27 1620 25 0.20 / 29.26 5 7
3 7 2003.80 40 14.85 2826 1679 1.88 / 30.94 7 7
4 13 1405.80 20 14.93 2119 633 2.52 / 31.57 5 12
5 13 647.88 20 15.12 1164 352 2.87 / 31.92 5 12
6 13 13.76 20 15.28 343 105 2.97 / 32.03 6 19
7 8 0.04 323 15.21 324 1592 4.56 / 33.62 6 143
Average= 3.74
(KJ/cycle)

Cycle 7 GMT 10/ 5/2024 7:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.00 25 15.20 455 173 0.17 / 24.73 6 6
2 3 1021.12 1 15.27 1620 25 0.20 / 24.76 5 7
3 7 2006.20 40 14.84 2840 1686 1.88 / 26.45 7 8
4 13 1283.48 20 14.96 1981 593 2.48 / 27.04 5 12
5 13 561.68 20 15.14 1066 323 2.80 / 27.36 5 12
6 8 0.08 340 15.22 327 1692 4.49 / 29.05 6 132
Average= 3.63
(KJ/cycle)

Cycle 6 GMT 30/ 4/2024 0:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.28 25 15.19 471 179 0.18 / 20.39 6 6
2 7 2005.24 40 14.85 2832 1682 1.86 / 22.07 6 7
3 13 1179.92 20 15.00 1839 552 2.41 / 22.62 5 11
4 13 486.24 20 15.17 964 292 2.71 / 22.92 5 12
5 8 0.28 343 15.22 315 1644 4.35 / 24.56 6 131
Average= 3.51
(KJ/cycle)

Cycle 5 GMT 19/ 4/2024 17:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.16 31 15.21 450 212 0.21 / 15.96 6 6
2 3 770.28 -4 15.55 7 0 0.00 / 15.96 6 6
3 7 2003.04 40 14.85 2827 1679 1.89 / 17.64 6 8
4 13 1233.00 20 15.00 1899 570 2.46 / 18.21 5 11
5 13 511.36 20 15.17 997 302 2.76 / 18.51 5 12
6 8 0.00 342 15.23 327 1703 4.47 / 20.21 6 141
Average= 3.37
(KJ/cycle)

Cycle 4 GMT 9/ 4/2024 11:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.96 23 15.23 437 153 0.15 / 11.53 6 6
2 10 1018.48 5 15.17 1594 121 0.27 / 11.65 6 6
3 10 1069.88 3 15.18 1669 76 0.35 / 11.73 6 6
4 10 1124.04 3 15.16 1727 79 0.43 / 11.81 6 6
5 10 1157.24 3 15.16 1780 81 0.51 / 11.89 5 6
6 10 1202.36 3 15.14 1838 83 0.59 / 11.97 5 6
7 3 1129.04 3 15.19 1757 80 0.67 / 12.05 5 6
8 7 1507.60 40 15.05 2216 1334 2.01 / 13.38 6 7
9 13 1065.80 20 15.10 1688 510 2.52 / 13.89 5 9
10 13 351.64 20 15.25 779 238 2.75 / 14.13 5 10
11 8 0.24 338 15.26 313 1614 4.37 / 15.75 6 164
Average= 3.15
(KJ/cycle)

Cycle 3 GMT 8/ 4/2024 1:41: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.08 23 15.22 404 141 0.14 / 7.94 6 6
2 7 1511.04 41 15.06 2187 1350 1.49 / 9.29 6 8
3 13 969.36 20 15.13 1529 463 1.95 / 9.76 5 10
4 13 290.56 20 15.27 660 202 2.16 / 9.96 6 10
5 8 0.24 332 15.27 280 1419 3.58 / 11.38 6 168
Average= 2.84
(KJ/cycle)

Cycle 2 GMT 6/ 4/2024 15:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.64 31 15.19 407 192 0.19 / 4.37 6 6
2 3 751.32 -4 15.51 7 0 0.00 / 4.37 6 6
3 7 1506.16 40 15.05 2185 1315 1.51 / 5.68 6 7
4 13 1069.64 20 15.09 1659 501 2.01 / 6.19 5 9
5 13 369.72 20 15.23 761 232 2.24 / 6.42 5 10
6 8 0.48 336 15.25 270 1383 3.62 / 7.80 6 133
Average= 2.60
(KJ/cycle)

Cycle 1 GMT 5/ 4/2024 5:55: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.44 31 15.36 407 194 0.19 / 1.92 6 6
2 3 757.28 -4 15.51 7 0 0.00 / 1.92 6 6
3 7 881.64 40 15.18 1402 851 1.05 / 2.78 6 9
4 8 0.00 343 15.26 268 1403 2.45 / 4.18 6 141
Average= 2.09
(KJ/cycle)

Cycle 0 GMT 4/ 4/2024 19:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 126.64 30 15.53 439 205 0.20 / 0.20 6 6
2 7 139.08 40 15.51 430 267 0.47 / 0.47 6 6
3 8 0.20 327 15.46 249 1259 1.73 / 1.73 6 147
Average= 1.73
(KJ/cycle)