Cycle 48 GMT 17/12/2024 11: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.16 35 14.78 414 214 0.21 / 225.22 9 13
2 7 2006.28 40 14.36 3243 1863 2.08 / 227.08 13 15
3 13 1447.72 20 14.40 2472 712 2.79 / 227.80 10 15
4 13 899.84 20 14.52 1689 490 3.28 / 228.29 11 16
5 13 241.88 20 14.76 651 192 3.47 / 228.48 11 15
6 8 0.12 325 14.80 267 1284 4.76 / 229.76 11 155
Average= 4.69
(KJ/cycle)

Cycle 47 GMT 7/12/2024 4:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 35 14.78 425 220 0.22 / 220.39 9 13
2 7 2005.40 40 14.36 3241 1862 2.08 / 222.25 13 15
3 13 1552.08 20 14.38 2590 745 2.83 / 222.99 10 15
4 13 987.96 20 14.49 1794 520 3.35 / 223.51 10 16
5 13 302.72 20 14.73 754 222 3.57 / 223.73 11 15
6 8 0.28 327 14.80 263 1273 4.84 / 225.01 11 147
Average= 4.69
(KJ/cycle)

Cycle 46 GMT 26/11/2024 21:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.00 35 14.79 423 219 0.22 / 215.51 9 13
2 7 2003.04 40 14.38 3227 1856 2.08 / 217.37 13 14
3 13 1541.76 20 14.38 2611 751 2.83 / 218.12 10 15
4 13 972.04 20 14.51 1763 512 3.34 / 218.63 10 16
5 13 375.44 20 14.71 865 254 3.59 / 218.89 11 15
6 8 0.04 327 14.80 264 1278 4.87 / 220.17 11 161
Average= 4.68
(KJ/cycle)

Cycle 45 GMT 16/11/2024 15:34:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 35 14.79 410 212 0.21 / 210.64 9 13
2 7 2003.80 40 14.38 3252 1871 2.08 / 212.51 13 15
3 13 1450.72 20 14.41 2474 713 2.80 / 213.22 10 15
4 13 1001.96 20 14.50 1831 531 3.33 / 213.75 10 16
5 13 396.72 20 14.71 906 267 3.59 / 214.02 11 15
6 8 0.16 325 14.81 265 1276 4.87 / 215.30 11 161
Average= 4.68
(KJ/cycle)

Cycle 44 GMT 6/11/2024 9:14: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.60 35 14.79 422 218 0.22 / 205.70 9 13
2 7 2005.28 41 14.37 3258 1920 2.14 / 207.61 13 15
3 13 1539.32 20 14.39 2610 751 2.89 / 208.37 10 15
4 13 1062.28 20 14.49 1884 546 3.44 / 208.91 10 16
5 13 343.60 20 14.74 815 240 3.68 / 209.15 11 15
6 8 0.24 327 14.82 263 1275 4.95 / 210.43 11 161
Average= 4.68
(KJ/cycle)

Cycle 43 GMT 27/10/2024 2:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.08 35 14.81 441 229 0.23 / 200.88 9 13
2 7 2009.36 40 14.37 3241 1863 2.09 / 202.75 14 14
3 13 1454.92 20 14.41 2458 708 2.80 / 203.45 10 15
4 13 1009.60 20 14.49 1845 535 3.33 / 203.99 10 16
5 13 305.24 20 14.75 751 222 3.56 / 204.21 11 15
6 8 -0.04 325 14.82 263 1267 4.82 / 205.48 11 138
Average= 4.67
(KJ/cycle)

Cycle 42 GMT 16/10/2024 20:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.12 34 14.79 439 221 0.22 / 196.07 9 13
2 7 2011.44 40 14.38 3237 1862 2.08 / 197.93 14 15
3 13 1454.12 20 14.43 2465 711 2.79 / 198.64 10 15
4 13 906.44 20 14.56 1687 491 3.29 / 199.13 10 15
5 13 326.96 20 14.76 798 236 3.52 / 199.37 11 15
6 8 0.20 323 14.83 268 1284 4.80 / 200.65 11 148
Average= 4.67
(KJ/cycle)

Cycle 41 GMT 6/10/2024 13:42:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.68 34 14.81 436 220 0.22 / 191.24 9 13
2 7 2008.80 40 14.38 3242 1865 2.08 / 193.10 14 15
3 13 1447.32 20 14.43 2463 711 2.80 / 193.81 10 15
4 13 989.88 20 14.53 1784 518 3.31 / 194.33 10 16
5 13 295.64 20 14.76 744 220 3.53 / 194.55 11 15
6 8 0.04 327 14.83 268 1300 4.83 / 195.85 11 157
Average= 4.66
(KJ/cycle)

Cycle 40 GMT 26/ 9/2024 7:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.68 34 14.83 437 220 0.22 / 186.36 9 13
2 7 2009.64 41 14.39 3288 1940 2.16 / 188.30 13 15
3 13 1437.72 20 14.45 2447 707 2.87 / 189.01 10 15
4 13 897.52 20 14.58 1661 484 3.35 / 189.49 10 16
5 13 313.76 20 14.78 774 229 3.58 / 189.72 11 15
6 8 0.12 323 14.84 270 1294 4.87 / 191.02 11 141
Average= 4.66
(KJ/cycle)

Cycle 39 GMT 16/ 9/2024 0:38:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.68 32 14.83 450 214 0.21 / 181.44 9 13
2 10 1062.00 3 14.79 1905 85 0.30 / 181.52 10 14
3 3 1031.24 1 14.82 1848 27 0.33 / 181.55 10 14
4 7 2002.52 41 14.37 3250 1915 2.24 / 183.46 14 15
5 13 1432.68 20 14.43 2479 715 2.96 / 184.18 10 15
6 13 880.60 20 14.56 1656 482 3.44 / 184.66 10 16
7 13 206.36 20 14.80 615 182 3.62 / 184.84 11 15
8 8 0.16 323 14.84 271 1299 4.92 / 186.14 11 141
Average= 4.65
(KJ/cycle)

Cycle 38 GMT 5/ 9/2024 17:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.40 31 14.81 430 197 0.20 / 176.55 9 13
2 10 1011.04 3 14.69 1802 79 0.28 / 176.63 10 15
3 3 956.68 -1 15.22 0 0 0.08 / 176.63 10 15
4 7 2011.08 40 14.41 3268 1884 2.16 / 178.52 15 14
5 13 1439.32 20 14.47 2425 702 2.86 / 179.22 10 15
6 13 908.92 20 14.60 1695 495 3.36 / 179.71 10 15
7 13 325.16 20 14.79 788 233 3.59 / 179.95 11 15
8 8 0.32 325 14.86 264 1275 4.87 / 181.22 11 156
Average= 4.65
(KJ/cycle)

Cycle 37 GMT 26/ 8/2024 11:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.00 31 14.78 446 204 0.20 / 171.70 9 13
2 7 2009.08 40 14.38 3258 1874 2.08 / 173.58 14 15
3 13 1369.84 20 14.46 2357 682 2.76 / 174.26 10 16
4 13 910.24 20 14.56 1701 495 3.26 / 174.76 10 16
5 13 218.68 20 14.79 646 191 3.45 / 174.95 11 16
6 8 0.00 334 14.82 285 1411 4.86 / 176.36 11 146
Average= 4.64
(KJ/cycle)

Cycle 36 GMT 16/ 8/2024 4:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.40 33 14.79 450 220 0.22 / 166.85 9 14
2 3 955.56 -1 15.22 0 0 0.00 / 166.85 9 14
3 7 2003.12 40 14.37 3278 1884 2.10 / 168.74 14 15
4 13 1333.88 20 14.47 2312 669 2.77 / 169.41 10 16
5 13 787.08 20 14.59 1521 444 3.22 / 169.85 10 16
6 13 222.92 20 14.78 665 197 3.41 / 170.05 11 17
7 8 -0.04 336 14.81 292 1453 4.87 / 171.50 11 142
Average= 4.64
(KJ/cycle)

Cycle 35 GMT 5/ 8/2024 21:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.16 33 14.80 457 223 0.22 / 161.92 9 14
2 7 2007.88 40 14.39 3229 1859 2.08 / 163.77 14 15
3 13 1337.76 20 14.49 2303 667 2.75 / 164.44 10 16
4 13 896.56 20 14.56 1685 491 3.24 / 164.93 10 16
5 13 304.64 20 14.74 798 235 3.48 / 165.17 11 17
6 8 0.88 338 14.81 293 1467 4.94 / 166.63 11 150
Average= 4.63
(KJ/cycle)

Cycle 34 GMT 26/ 7/2024 14:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.48 33 14.81 463 226 0.23 / 157.04 9 13
2 7 2002.12 40 14.40 3221 1855 2.08 / 158.89 13 15
3 13 1414.68 20 14.47 2418 700 2.78 / 159.59 10 16
4 13 951.52 20 14.56 1745 508 3.29 / 160.10 10 16
5 13 230.92 20 14.79 667 197 3.49 / 160.30 11 16
6 8 0.12 332 14.83 283 1393 4.88 / 161.69 11 142
Average= 4.62
(KJ/cycle)

Cycle 33 GMT 16/ 7/2024 7:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.80 33 14.82 439 215 0.21 / 152.08 9 13
2 3 1025.80 1 14.78 1874 28 0.24 / 152.10 10 15
3 7 2006.60 41 14.38 3243 1912 2.15 / 154.01 15 15
4 13 1317.40 20 14.49 2284 662 2.82 / 154.68 10 16
5 13 882.28 20 14.58 1647 480 3.30 / 155.16 10 16
6 13 300.48 20 14.77 785 232 3.53 / 155.39 11 16
7 13 47.76 20 14.86 366 109 3.64 / 155.50 11 16
8 8 0.00 312 14.83 284 1314 4.95 / 156.81 11 152
Average= 4.61
(KJ/cycle)

Cycle 32 GMT 6/ 7/2024 1: 7: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.96 32 14.82 437 207 0.21 / 147.21 9 13
2 3 1020.48 1 14.79 1854 27 0.23 / 147.24 10 15
3 7 2008.00 40 14.41 3243 1869 2.10 / 149.11 15 15
4 13 1435.52 20 14.48 2429 703 2.81 / 149.81 10 15
5 13 878.68 20 14.59 1650 481 3.29 / 150.29 10 16
6 13 302.48 20 14.79 773 229 3.52 / 150.52 11 16
7 8 0.08 327 14.85 276 1340 4.86 / 151.86 11 153
Average= 4.60
(KJ/cycle)

Cycle 31 GMT 25/ 6/2024 18:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.76 32 14.82 433 205 0.21 / 142.26 9 13
2 7 2005.48 40 14.41 3237 1866 2.07 / 144.13 13 15
3 13 1436.80 20 14.48 2451 710 2.78 / 144.84 10 15
4 13 966.60 20 14.57 1755 511 3.29 / 145.35 10 16
5 13 370.92 20 14.75 870 257 3.55 / 145.61 11 16
6 8 0.12 332 14.84 283 1394 4.94 / 147.00 12 136
Average= 4.59
(KJ/cycle)

Cycle 30 GMT 15/ 6/2024 12:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.52 32 14.82 433 205 0.21 / 137.38 9 13
2 7 2007.16 41 14.41 3217 1901 2.11 / 139.28 13 15
3 13 1400.08 20 14.49 2422 702 2.81 / 139.99 10 16
4 13 835.52 20 14.61 1573 460 3.27 / 140.45 10 16
5 13 252.96 20 14.79 709 210 3.48 / 140.66 11 16
6 8 0.00 332 14.84 285 1404 4.88 / 142.06 11 152
Average= 4.58
(KJ/cycle)

Cycle 29 GMT 5/ 6/2024 5:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.24 32 14.81 440 209 0.21 / 132.51 9 13
2 7 2003.52 40 14.40 3270 1884 2.09 / 134.39 13 15
3 13 1424.88 20 14.50 2398 695 2.79 / 135.08 10 15
4 13 859.16 20 14.62 1594 466 3.25 / 135.55 10 16
5 13 283.48 20 14.78 756 223 3.48 / 135.77 11 16
6 8 -0.08 332 14.84 285 1404 4.88 / 137.18 11 137
Average= 4.57
(KJ/cycle)

Cycle 28 GMT 25/ 5/2024 23:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.00 32 14.81 440 209 0.21 / 127.66 9 13
2 7 2006.84 40 14.42 3226 1861 2.07 / 129.52 13 15
3 13 1427.92 20 14.50 2416 701 2.77 / 130.22 10 15
4 13 767.96 20 14.63 1485 435 3.20 / 130.66 10 16
5 13 223.40 20 14.80 659 195 3.40 / 130.85 11 16
6 8 -0.04 336 14.83 290 1445 4.84 / 132.30 11 137
Average= 4.56
(KJ/cycle)

Cycle 27 GMT 15/ 5/2024 16:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.20 32 14.83 444 211 0.21 / 122.77 9 13
2 7 2003.64 40 14.42 3247 1873 2.08 / 124.64 13 15
3 13 1315.08 20 14.52 2290 665 2.75 / 125.31 10 16
4 13 873.32 20 14.60 1653 483 3.23 / 125.79 10 16
5 13 278.64 20 14.78 752 222 3.45 / 126.01 11 16
6 8 0.00 336 14.84 289 1441 4.89 / 127.45 11 148
Average= 4.55
(KJ/cycle)

Cycle 26 GMT 5/ 5/2024 9:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.88 32 14.81 448 212 0.21 / 118.34 9 13
2 7 1632.96 40 14.55 2723 1585 1.80 / 119.93 13 15
3 13 1313.28 20 14.57 2264 660 2.46 / 120.59 10 16
4 13 754.44 20 14.67 1466 430 2.89 / 121.02 10 16
5 13 92.72 20 14.89 446 133 3.02 / 121.15 11 16
6 8 -0.04 329 14.86 288 1408 4.43 / 122.56 11 134
Average= 4.54
(KJ/cycle)

Cycle 25 GMT 25/ 4/2024 0:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.16 32 14.83 438 208 0.21 / 113.54 9 13
2 7 2008.04 40 14.41 3280 1891 2.10 / 115.43 13 15
3 13 1327.28 20 14.53 2266 658 2.76 / 116.09 10 16
4 13 880.20 20 14.61 1642 480 3.24 / 116.57 10 16
5 13 102.96 20 14.86 462 137 3.37 / 116.71 11 16
6 8 0.04 332 14.85 289 1425 4.80 / 118.13 11 137
Average= 4.54
(KJ/cycle)

Cycle 24 GMT 14/ 4/2024 17:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.28 32 14.84 444 211 0.21 / 108.75 9 13
2 7 1992.20 40 14.42 3222 1858 2.07 / 110.61 13 15
3 13 1409.96 20 14.51 2396 695 2.76 / 111.31 10 16
4 13 838.68 20 14.62 1603 469 3.23 / 111.77 10 16
5 13 168.48 20 14.84 558 166 3.40 / 111.94 11 16
6 8 -0.12 332 14.86 282 1391 4.79 / 113.33 11 143
Average= 4.53
(KJ/cycle)

Cycle 23 GMT 4/ 4/2024 6:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.32 32 14.84 429 204 0.20 / 103.97 9 13
2 3 1021.48 1 14.78 1866 28 0.23 / 104.00 10 15
3 7 2004.60 40 14.42 3246 1872 2.10 / 105.87 15 15
4 13 1415.52 20 14.52 2401 697 2.80 / 106.57 10 16
5 13 844.04 20 14.63 1571 460 3.26 / 107.03 10 16
6 13 155.88 20 14.86 523 155 3.42 / 107.18 11 16
7 8 -0.08 329 14.87 278 1360 4.78 / 108.54 11 151
Average= 4.52
(KJ/cycle)

Cycle 22 GMT 25/ 3/2024 0:19: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.44 34 14.85 433 219 0.22 / 99.19 9 13
2 3 950.32 -1 15.26 0 0 0.00 / 99.19 9 13
3 7 2008.44 41 14.43 3243 1919 2.14 / 101.11 13 15
4 13 1323.52 20 14.53 2315 673 2.81 / 101.78 10 16
5 13 875.16 20 14.61 1638 479 3.29 / 102.26 10 16
6 13 102.48 20 14.88 455 135 3.42 / 102.40 11 16
7 8 0.12 325 14.87 283 1368 4.79 / 103.76 11 151
Average= 4.51
(KJ/cycle)

Cycle 21 GMT 14/ 3/2024 17:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.40 34 14.86 435 220 0.22 / 94.44 9 13
2 7 2005.52 40 14.43 3241 1871 2.09 / 96.31 13 15
3 13 1318.40 20 14.54 2269 660 2.75 / 96.97 10 16
4 13 854.16 20 14.61 1622 474 3.22 / 97.44 11 16
5 13 162.92 20 14.85 555 165 3.39 / 97.60 11 16
6 8 0.00 329 14.86 280 1369 4.76 / 98.97 11 152
Average= 4.50
(KJ/cycle)

Cycle 20 GMT 4/ 3/2024 10:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.88 34 14.86 425 215 0.21 / 89.63 9 13
2 7 2002.40 40 14.44 3230 1866 2.08 / 91.50 13 15
3 13 1437.88 20 14.51 2458 713 2.79 / 92.21 10 15
4 13 975.36 20 14.60 1775 518 3.31 / 92.73 10 16
5 13 174.40 20 14.87 557 166 3.48 / 92.89 11 16
6 8 -0.04 325 14.89 273 1321 4.80 / 94.22 11 159
Average= 4.49
(KJ/cycle)

Cycle 19 GMT 23/ 2/2024 3:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.84 34 14.87 438 221 0.22 / 84.89 9 13
2 7 2002.28 40 14.43 3260 1882 2.10 / 86.77 13 15
3 13 1417.92 20 14.52 2409 700 2.80 / 87.47 10 16
4 13 864.28 20 14.63 1643 481 3.28 / 87.95 11 16
5 13 183.88 20 14.87 572 170 3.45 / 88.12 11 16
6 8 0.08 321 14.89 271 1295 4.75 / 89.42 11 152
Average= 4.47
(KJ/cycle)

Cycle 18 GMT 12/ 2/2024 21: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.20 34 14.89 417 211 0.21 / 80.14 9 13
2 7 2006.64 40 14.44 3248 1876 2.09 / 82.02 13 15
3 13 1432.52 20 14.52 2446 710 2.80 / 82.73 10 15
4 13 873.44 20 14.64 1625 476 3.27 / 83.21 11 16
5 13 188.72 20 14.88 562 167 3.44 / 83.37 11 15
6 8 0.04 323 14.90 269 1295 4.74 / 84.67 11 139
Average= 4.46
(KJ/cycle)

Cycle 17 GMT 2/ 2/2024 14:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.00 34 14.87 437 221 0.22 / 75.31 9 13
2 3 1027.92 1 14.85 1849 27 0.25 / 75.34 10 15
3 7 2006.00 40 14.45 3252 1880 2.13 / 77.22 15 15
4 13 1432.84 20 14.52 2476 719 2.85 / 77.94 10 16
5 13 880.00 20 14.64 1645 482 3.33 / 78.42 11 16
6 13 285.00 20 14.84 736 218 3.55 / 78.64 11 16
7 8 -0.08 323 14.90 269 1295 4.84 / 79.93 12 140
Average= 4.44
(KJ/cycle)

Cycle 16 GMT 23/ 1/2024 7:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.80 33 14.88 430 211 0.21 / 70.45 9 13
2 3 1024.60 1 14.85 1773 26 0.24 / 70.48 10 15
3 7 2003.28 40 14.46 3246 1877 2.11 / 72.36 15 15
4 13 1432.44 20 14.53 2438 708 2.82 / 73.06 10 16
5 13 973.28 20 14.61 1803 527 3.35 / 73.59 10 16
6 13 268.32 20 14.86 701 208 3.56 / 73.80 11 15
7 8 0.24 323 14.91 268 1291 4.85 / 75.09 11 146
Average= 4.42
(KJ/cycle)

Cycle 15 GMT 13/ 1/2024 1:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.80 32 14.86 442 210 0.21 / 65.64 9 13
2 3 1028.40 1 14.83 1884 28 0.24 / 65.67 10 15
3 7 2005.80 41 14.46 3243 1923 2.16 / 67.59 15 15
4 13 1421.16 20 14.55 2395 697 2.86 / 68.28 10 16
5 13 865.32 20 14.65 1617 474 3.33 / 68.76 10 16
6 13 181.00 20 14.89 549 163 3.49 / 68.92 11 16
7 8 0.04 323 14.91 274 1320 4.81 / 70.24 11 144
Average= 4.39
(KJ/cycle)

Cycle 14 GMT 2/ 1/2024 18:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.12 32 14.87 432 206 0.21 / 60.80 9 13
2 7 2002.72 40 14.47 3218 1863 2.07 / 62.66 13 15
3 13 1420.36 20 14.54 2405 699 2.77 / 63.36 10 16
4 13 948.44 20 14.62 1752 512 3.28 / 63.87 10 16
5 13 240.68 20 14.86 675 201 3.48 / 64.07 11 16
6 8 0.04 329 14.89 277 1357 4.84 / 65.43 11 148
Average= 4.36
(KJ/cycle)

Cycle 13 GMT 23/12/2023 12:18:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 32 14.88 431 205 0.21 / 55.98 9 13
2 7 2002.60 40 14.47 3228 1868 2.07 / 57.85 13 15
3 13 1419.20 20 14.55 2393 696 2.77 / 58.55 10 15
4 13 868.04 20 14.64 1623 475 3.25 / 59.02 10 16
5 13 192.68 20 14.87 591 176 3.42 / 59.20 11 16
6 8 -0.04 329 14.89 284 1391 4.81 / 60.59 11 140
Average= 4.33
(KJ/cycle)

Cycle 12 GMT 13/12/2023 5:37: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.76 32 14.87 427 203 0.20 / 51.16 9 13
2 7 2002.60 40 14.46 3251 1880 2.08 / 53.04 13 15
3 13 1428.96 20 14.55 2406 700 2.78 / 53.74 10 16
4 13 958.92 20 14.62 1761 515 3.30 / 54.25 10 16
5 13 152.84 20 14.89 534 159 3.46 / 54.41 11 16
6 8 0.04 327 14.90 280 1364 4.82 / 55.78 11 136
Average= 4.29
(KJ/cycle)

Cycle 11 GMT 2/12/2023 22:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.92 32 14.86 432 205 0.21 / 46.41 9 13
2 7 2003.08 40 14.47 3213 1860 2.07 / 48.27 13 15
3 13 1310.00 20 14.56 2268 660 2.73 / 48.93 10 16
4 13 863.68 20 14.65 1605 470 3.20 / 49.40 10 16
5 13 180.32 20 14.88 577 172 3.37 / 49.58 11 16
6 8 0.00 332 14.89 279 1379 4.75 / 50.96 11 145
Average= 4.25
(KJ/cycle)

Cycle 10 GMT 22/11/2023 16:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.28 32 14.86 454 216 0.22 / 41.50 9 13
2 7 2003.16 41 14.46 3264 1935 2.15 / 43.43 13 15
3 13 1430.36 20 14.55 2437 709 2.86 / 44.14 10 16
4 13 960.36 20 14.62 1777 520 3.38 / 44.66 10 16
5 13 153.80 20 14.89 537 160 3.54 / 44.82 11 16
6 8 -0.20 334 14.90 279 1388 4.93 / 46.21 12 147
Average= 4.20
(KJ/cycle)

Cycle 9 GMT 12/11/2023 9:34:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.36 32 14.86 435 207 0.21 / 36.60 9 13
2 7 2007.68 40 14.47 3256 1885 2.09 / 38.48 13 15
3 13 1329.16 20 14.57 2297 669 2.76 / 39.15 10 16
4 13 882.12 20 14.64 1650 483 3.24 / 39.64 10 16
5 13 286.56 20 14.83 757 225 3.47 / 39.86 11 16
6 8 0.12 336 14.89 284 1421 4.89 / 41.28 11 133
Average= 4.13
(KJ/cycle)

Cycle 8 GMT 2/11/2023 2:47: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.56 32 14.88 425 202 0.20 / 31.84 9 13
2 7 2002.16 40 14.48 3200 1853 2.06 / 33.69 12 15
3 13 1311.08 20 14.58 2253 657 2.71 / 34.35 10 16
4 13 865.88 20 14.65 1630 478 3.19 / 34.83 10 16
5 13 168.32 20 14.89 559 166 3.36 / 35.00 11 16
6 8 0.08 336 14.89 279 1396 4.75 / 36.39 11 139
Average= 4.04
(KJ/cycle)

Cycle 7 GMT 22/10/2023 20: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.68 32 14.86 427 203 0.20 / 27.08 9 14
2 7 2007.24 40 14.48 3238 1875 2.08 / 28.96 14 15
3 13 1335.20 20 14.57 2289 667 2.75 / 29.62 10 16
4 13 888.24 20 14.65 1654 485 3.23 / 30.11 10 16
5 13 107.40 20 14.92 447 133 3.36 / 30.24 11 16
6 8 0.00 336 14.90 279 1397 4.76 / 31.64 11 142
Average= 3.95
(KJ/cycle)

Cycle 6 GMT 12/10/2023 13:10:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.60 32 14.87 431 205 0.21 / 22.22 9 14
2 3 1018.76 1 14.85 1860 28 0.23 / 22.24 10 13
3 7 2002.92 40 14.48 3224 1867 2.10 / 24.11 13 15
4 13 1404.96 20 14.56 2395 697 2.80 / 24.81 10 16
5 13 827.80 20 14.67 1582 464 3.26 / 25.27 11 16
6 13 247.88 20 14.85 693 206 3.47 / 25.48 11 16
7 8 0.08 338 14.89 278 1399 4.87 / 26.88 11 131
Average= 3.84
(KJ/cycle)

Cycle 5 GMT 2/10/2023 6:22:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.60 31 14.88 445 205 0.21 / 17.33 9 14
2 3 1028.08 1 14.87 1850 28 0.23 / 17.36 10 14
3 7 2008.12 41 14.48 3244 1926 2.16 / 19.29 14 15
4 13 1416.04 20 14.56 2422 705 2.86 / 19.99 10 15
5 13 836.96 20 14.67 1575 462 3.33 / 20.45 10 16
6 13 151.84 20 14.90 513 153 3.48 / 20.61 11 16
7 8 -0.04 338 14.90 279 1405 4.88 / 22.01 11 131
Average= 3.67
(KJ/cycle)

Cycle 4 GMT 21/ 9/2023 23:46: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.88 32 14.87 436 207 0.21 / 13.06 9 14
2 7 1506.00 41 14.65 2555 1535 1.74 / 14.60 14 15
3 13 1212.48 20 14.66 2141 628 2.37 / 15.23 10 16
4 13 753.88 20 14.73 1473 434 2.80 / 15.66 11 16
5 13 33.56 20 14.97 337 101 2.90 / 15.76 11 16
6 8 0.16 334 14.92 274 1365 4.27 / 17.13 11 141
Average= 3.43
(KJ/cycle)

Cycle 3 GMT 20/ 9/2023 14: 2: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.40 31 14.86 467 215 0.22 / 8.82 9 14
2 7 1524.20 40 14.65 2565 1503 1.72 / 10.33 12 15
3 13 1230.76 20 14.65 2161 633 2.35 / 10.96 10 16
4 13 693.12 20 14.74 1398 412 2.76 / 11.37 11 16
5 13 56.48 20 14.95 373 112 2.88 / 11.48 11 16
6 8 0.04 334 14.92 276 1375 4.25 / 12.86 11 133
Average= 3.21
(KJ/cycle)

Cycle 2 GMT 19/ 9/2023 4: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.24 31 14.89 463 214 0.21 / 4.63 9 14
2 7 1523.80 40 14.64 2569 1504 1.72 / 6.13 13 15
3 13 1221.48 20 14.65 2167 635 2.35 / 6.77 10 16
4 13 668.16 20 14.74 1347 397 2.75 / 7.17 11 16
5 8 0.04 355 14.92 272 1441 4.19 / 8.61 11 139
Average= 2.87
(KJ/cycle)

Cycle 1 GMT 17/ 9/2023 18: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.20 31 15.07 411 192 0.19 / 1.90 9 13
2 7 1000.72 40 14.76 1809 1068 1.26 / 2.97 13 16
3 13 59.04 20 15.00 368 110 1.37 / 3.08 11 16
4 8 0.08 334 14.96 268 1339 2.71 / 4.42 11 134
Average= 2.21
(KJ/cycle)

Cycle 0 GMT 17/ 9/2023 7:43:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 125.20 30 15.24 431 197 0.20 / 0.20 10 13
2 7 136.64 40 15.22 456 278 0.47 / 0.47 13 14
3 8 0.20 334 15.18 243 1232 1.71 / 1.71 11 146
Average= 1.71