SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.28 | 34 | 15.05 | 455 | 233 | 0.23 / 271.24 | 6 | 6 |
2 | 3 | 1030.16 | 1 | 15.09 | 1765 | 27 | 0.26 / 271.27 | 5 | 14 |
3 | 7 | 2019.12 | 40 | 14.63 | 3108 | 1819 | 2.08 / 273.09 | 14 | 14 |
4 | 13 | 1580.32 | 20 | 14.67 | 2506 | 735 | 2.81 / 273.82 | 5 | 19 |
5 | 13 | 908.80 | 20 | 14.80 | 1592 | 471 | 3.28 / 274.29 | 5 | 26 |
6 | 13 | 236.08 | 20 | 15.03 | 653 | 196 | 3.48 / 274.49 | 5 | 23 |
7 | 13 | 53.84 | 20 | 15.08 | 383 | 116 | 3.60 / 274.60 | 6 | 21 |
8 | 8 | 0.16 | 244 | 15.04 | 295 | 1083 | 4.68 / 275.69 | 6 | 133 |
Average= | 4.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.72 | 35 | 15.03 | 449 | 236 | 0.24 / 266.49 | 6 | 6 |
2 | 7 | 2006.16 | 40 | 14.65 | 3062 | 1794 | 2.03 / 268.28 | 6 | 13 |
3 | 13 | 1672.32 | 20 | 14.67 | 2618 | 768 | 2.80 / 269.05 | 5 | 17 |
4 | 13 | 962.80 | 20 | 14.81 | 1664 | 493 | 3.29 / 269.54 | 5 | 28 |
5 | 13 | 369.56 | 20 | 15.00 | 849 | 255 | 3.55 / 269.80 | 5 | 25 |
6 | 13 | 51.96 | 20 | 15.10 | 377 | 114 | 3.66 / 269.91 | 5 | 20 |
7 | 8 | 0.00 | 246 | 15.06 | 296 | 1097 | 4.76 / 271.01 | 6 | 148 |
Average= | 4.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.24 | 35 | 15.03 | 467 | 246 | 0.25 / 261.79 | 6 | 6 |
2 | 7 | 2010.08 | 40 | 14.62 | 3110 | 1819 | 2.06 / 263.61 | 6 | 15 |
3 | 13 | 1451.00 | 20 | 14.70 | 2323 | 683 | 2.75 / 264.29 | 5 | 24 |
4 | 13 | 1082.92 | 20 | 14.75 | 1839 | 543 | 3.29 / 264.83 | 5 | 26 |
5 | 13 | 222.16 | 20 | 15.03 | 646 | 194 | 3.48 / 265.03 | 5 | 28 |
6 | 13 | 47.80 | 20 | 15.09 | 383 | 116 | 3.60 / 265.14 | 5 | 25 |
7 | 8 | -0.08 | 244 | 15.05 | 302 | 1109 | 4.71 / 266.25 | 6 | 156 |
Average= | 4.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.20 | 35 | 15.04 | 448 | 236 | 0.24 / 257.06 | 6 | 6 |
2 | 7 | 2004.36 | 40 | 14.64 | 3064 | 1794 | 2.03 / 258.86 | 6 | 15 |
3 | 13 | 1451.96 | 20 | 14.71 | 2340 | 688 | 2.72 / 259.55 | 5 | 21 |
4 | 13 | 1112.48 | 20 | 14.75 | 1890 | 558 | 3.28 / 260.10 | 5 | 25 |
5 | 13 | 276.88 | 20 | 15.03 | 713 | 214 | 3.49 / 260.32 | 5 | 25 |
6 | 13 | 41.28 | 20 | 15.10 | 370 | 112 | 3.60 / 260.43 | 6 | 21 |
7 | 8 | -0.12 | 244 | 15.05 | 303 | 1113 | 4.71 / 261.54 | 6 | 131 |
Average= | 4.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.08 | 34 | 15.07 | 455 | 233 | 0.23 / 252.28 | 6 | 6 |
2 | 3 | 1045.68 | 1 | 15.11 | 1783 | 27 | 0.26 / 252.31 | 5 | 14 |
3 | 7 | 2009.24 | 40 | 14.64 | 3078 | 1802 | 2.06 / 254.11 | 14 | 14 |
4 | 13 | 1562.92 | 20 | 14.68 | 2467 | 724 | 2.79 / 254.83 | 5 | 21 |
5 | 13 | 1072.88 | 20 | 14.76 | 1829 | 540 | 3.33 / 255.37 | 5 | 24 |
6 | 13 | 337.20 | 20 | 15.00 | 795 | 238 | 3.57 / 255.61 | 5 | 24 |
7 | 13 | 41.96 | 20 | 15.09 | 367 | 111 | 3.68 / 255.72 | 6 | 20 |
8 | 8 | 0.12 | 246 | 15.05 | 299 | 1107 | 4.78 / 256.83 | 6 | 152 |
Average= | 4.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.96 | 35 | 15.06 | 437 | 230 | 0.23 / 247.66 | 6 | 6 |
2 | 3 | 953.56 | -1 | 15.43 | 5 | 0 | 0.00 / 247.66 | 6 | 6 |
3 | 7 | 2005.52 | 40 | 14.65 | 3063 | 1795 | 2.03 / 249.45 | 6 | 12 |
4 | 13 | 1561.04 | 20 | 14.69 | 2497 | 734 | 2.76 / 250.19 | 5 | 18 |
5 | 13 | 955.92 | 20 | 14.83 | 1655 | 491 | 3.25 / 250.68 | 5 | 24 |
6 | 13 | 241.92 | 20 | 15.07 | 655 | 197 | 3.45 / 250.88 | 5 | 20 |
7 | 13 | 36.08 | 20 | 15.12 | 348 | 105 | 3.55 / 250.98 | 6 | 17 |
8 | 8 | 0.04 | 244 | 15.08 | 289 | 1063 | 4.62 / 252.05 | 6 | 157 |
Average= | 4.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.40 | 35 | 15.05 | 465 | 245 | 0.24 / 243.39 | 6 | 6 |
2 | 7 | 1543.36 | 40 | 14.81 | 2461 | 1458 | 1.70 / 244.84 | 6 | 18 |
3 | 13 | 1355.32 | 20 | 14.82 | 2205 | 654 | 2.36 / 245.50 | 5 | 23 |
4 | 13 | 911.32 | 20 | 14.88 | 1601 | 476 | 2.83 / 245.97 | 5 | 27 |
5 | 13 | 343.64 | 20 | 15.04 | 811 | 244 | 3.08 / 246.22 | 5 | 25 |
6 | 13 | 50.28 | 20 | 15.12 | 383 | 116 | 3.19 / 246.33 | 6 | 20 |
7 | 8 | -0.04 | 242 | 15.09 | 300 | 1096 | 4.29 / 247.43 | 6 | 154 |
Average= | 4.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.68 | 35 | 15.08 | 428 | 226 | 0.23 / 238.72 | 6 | 6 |
2 | 7 | 2014.56 | 40 | 14.64 | 3078 | 1802 | 2.03 / 240.52 | 6 | 12 |
3 | 13 | 1459.40 | 20 | 14.71 | 2355 | 693 | 2.72 / 241.22 | 5 | 20 |
4 | 13 | 990.44 | 20 | 14.80 | 1692 | 501 | 3.22 / 241.72 | 5 | 25 |
5 | 13 | 263.32 | 20 | 15.05 | 689 | 207 | 3.43 / 241.92 | 5 | 22 |
6 | 13 | 30.96 | 20 | 15.11 | 352 | 106 | 3.54 / 242.03 | 6 | 19 |
7 | 8 | -0.08 | 244 | 15.07 | 302 | 1110 | 4.65 / 243.14 | 6 | 166 |
Average= | 4.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.40 | 35 | 15.08 | 433 | 229 | 0.23 / 234.08 | 6 | 6 |
2 | 7 | 2005.04 | 40 | 14.66 | 3074 | 1803 | 2.03 / 235.88 | 6 | 12 |
3 | 13 | 1555.92 | 20 | 14.70 | 2463 | 724 | 2.76 / 236.61 | 5 | 18 |
4 | 13 | 892.52 | 20 | 14.86 | 1578 | 469 | 3.22 / 237.08 | 5 | 25 |
5 | 13 | 306.52 | 20 | 15.05 | 756 | 228 | 3.45 / 237.30 | 5 | 21 |
6 | 13 | 48.00 | 20 | 15.13 | 370 | 112 | 3.56 / 237.42 | 6 | 17 |
7 | 8 | 0.04 | 244 | 15.09 | 293 | 1079 | 4.64 / 238.49 | 6 | 152 |
Average= | 4.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.00 | 35 | 15.08 | 439 | 232 | 0.23 / 229.38 | 6 | 6 |
2 | 7 | 2005.40 | 40 | 14.66 | 3077 | 1804 | 2.04 / 231.18 | 6 | 12 |
3 | 13 | 1564.92 | 20 | 14.70 | 2510 | 738 | 2.77 / 231.92 | 5 | 19 |
4 | 13 | 990.20 | 20 | 14.82 | 1708 | 506 | 3.28 / 232.43 | 5 | 25 |
5 | 13 | 292.64 | 20 | 15.06 | 725 | 218 | 3.50 / 232.64 | 5 | 21 |
6 | 13 | 86.96 | 20 | 15.12 | 427 | 129 | 3.63 / 232.77 | 6 | 18 |
7 | 8 | 0.00 | 244 | 15.10 | 293 | 1080 | 4.71 / 233.85 | 6 | 135 |
Average= | 4.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.88 | 35 | 15.08 | 459 | 242 | 0.24 / 224.71 | 6 | 6 |
2 | 7 | 2004.72 | 40 | 14.66 | 3081 | 1807 | 2.05 / 226.51 | 6 | 13 |
3 | 13 | 1531.96 | 20 | 14.72 | 2429 | 715 | 2.76 / 227.23 | 5 | 20 |
4 | 13 | 974.56 | 20 | 14.83 | 1685 | 500 | 3.26 / 227.73 | 5 | 25 |
5 | 13 | 257.12 | 20 | 15.07 | 680 | 205 | 3.47 / 227.93 | 5 | 21 |
6 | 13 | 75.04 | 20 | 15.13 | 411 | 124 | 3.59 / 228.06 | 6 | 17 |
7 | 8 | 0.04 | 244 | 15.10 | 295 | 1087 | 4.68 / 229.15 | 6 | 143 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.76 | 35 | 15.08 | 465 | 245 | 0.25 / 220.13 | 6 | 6 |
2 | 7 | 1852.92 | 40 | 14.70 | 2850 | 1676 | 1.92 / 221.80 | 6 | 17 |
3 | 13 | 1543.16 | 20 | 14.73 | 2449 | 721 | 2.64 / 222.52 | 5 | 23 |
4 | 13 | 1064.60 | 20 | 14.81 | 1812 | 537 | 3.18 / 223.06 | 5 | 26 |
5 | 13 | 212.68 | 20 | 15.10 | 616 | 186 | 3.37 / 223.25 | 5 | 21 |
6 | 13 | 48.68 | 20 | 15.14 | 375 | 114 | 3.48 / 223.36 | 6 | 18 |
7 | 8 | 0.04 | 244 | 15.10 | 300 | 1105 | 4.58 / 224.47 | 6 | 160 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.20 | 35 | 15.10 | 447 | 236 | 0.24 / 215.49 | 6 | 6 |
2 | 7 | 2017.76 | 40 | 14.67 | 3071 | 1802 | 2.04 / 217.29 | 6 | 12 |
3 | 13 | 1574.20 | 20 | 14.71 | 2511 | 739 | 2.78 / 218.03 | 5 | 19 |
4 | 13 | 977.96 | 20 | 14.84 | 1685 | 500 | 3.28 / 218.53 | 5 | 26 |
5 | 13 | 182.80 | 20 | 15.11 | 574 | 173 | 3.45 / 218.70 | 5 | 20 |
6 | 8 | 0.12 | 263 | 15.11 | 297 | 1180 | 4.63 / 219.88 | 6 | 154 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.48 | 35 | 15.09 | 453 | 239 | 0.24 / 210.85 | 6 | 6 |
2 | 7 | 2013.12 | 40 | 14.67 | 3100 | 1819 | 2.06 / 212.67 | 6 | 12 |
3 | 13 | 1494.84 | 20 | 14.75 | 2370 | 699 | 2.76 / 213.37 | 5 | 21 |
4 | 13 | 937.52 | 20 | 14.86 | 1639 | 487 | 3.24 / 213.86 | 5 | 26 |
5 | 13 | 242.68 | 20 | 15.10 | 669 | 202 | 3.45 / 214.06 | 5 | 21 |
6 | 8 | 0.00 | 263 | 15.12 | 299 | 1189 | 4.64 / 215.25 | 6 | 156 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.92 | 35 | 15.10 | 451 | 238 | 0.24 / 206.28 | 6 | 6 |
2 | 7 | 2011.16 | 40 | 14.68 | 3049 | 1790 | 2.03 / 208.08 | 8 | 12 |
3 | 13 | 1471.76 | 20 | 14.74 | 2341 | 690 | 2.72 / 208.77 | 5 | 21 |
4 | 13 | 922.56 | 20 | 14.87 | 1630 | 485 | 3.20 / 209.25 | 5 | 26 |
5 | 13 | 215.60 | 20 | 15.11 | 623 | 188 | 3.39 / 209.44 | 5 | 21 |
6 | 8 | 0.12 | 261 | 15.12 | 298 | 1176 | 4.57 / 210.61 | 6 | 149 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.16 | 35 | 15.11 | 449 | 237 | 0.24 / 201.59 | 6 | 6 |
2 | 7 | 2004.92 | 40 | 14.68 | 3069 | 1802 | 2.04 / 203.39 | 6 | 12 |
3 | 13 | 1658.60 | 20 | 14.70 | 2632 | 774 | 2.81 / 204.16 | 5 | 19 |
4 | 13 | 943.72 | 20 | 14.87 | 1639 | 487 | 3.30 / 204.65 | 5 | 26 |
5 | 13 | 250.04 | 20 | 15.10 | 682 | 206 | 3.51 / 204.86 | 5 | 20 |
6 | 8 | 0.08 | 263 | 15.13 | 299 | 1190 | 4.70 / 206.05 | 6 | 150 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.68 | 35 | 15.12 | 451 | 239 | 0.24 / 197.00 | 6 | 6 |
2 | 7 | 2019.04 | 40 | 14.67 | 3090 | 1813 | 2.05 / 198.81 | 6 | 13 |
3 | 13 | 1469.84 | 20 | 14.75 | 2363 | 697 | 2.75 / 199.51 | 5 | 21 |
4 | 13 | 996.60 | 20 | 14.85 | 1709 | 508 | 3.26 / 200.02 | 5 | 26 |
5 | 13 | 110.76 | 20 | 15.16 | 474 | 144 | 3.40 / 200.16 | 5 | 19 |
6 | 8 | 0.12 | 263 | 15.13 | 299 | 1190 | 4.59 / 201.35 | 6 | 174 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.16 | 35 | 15.12 | 451 | 239 | 0.24 / 192.37 | 6 | 6 |
2 | 7 | 2005.68 | 40 | 14.68 | 3062 | 1798 | 2.04 / 194.17 | 6 | 13 |
3 | 13 | 1530.84 | 20 | 14.74 | 2457 | 724 | 2.76 / 194.90 | 5 | 21 |
4 | 13 | 937.84 | 20 | 14.88 | 1654 | 492 | 3.25 / 195.39 | 5 | 26 |
5 | 13 | 141.04 | 20 | 15.15 | 526 | 159 | 3.41 / 195.55 | 5 | 20 |
6 | 13 | 28.24 | 20 | 15.18 | 353 | 107 | 3.52 / 195.65 | 6 | 20 |
7 | 8 | 0.00 | 242 | 15.13 | 302 | 1106 | 4.63 / 196.76 | 6 | 154 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.28 | 35 | 15.13 | 438 | 232 | 0.23 / 187.72 | 6 | 6 |
2 | 7 | 2015.76 | 40 | 14.68 | 3079 | 1808 | 2.04 / 189.53 | 8 | 13 |
3 | 13 | 1571.64 | 20 | 14.74 | 2493 | 735 | 2.77 / 190.27 | 5 | 20 |
4 | 13 | 897.76 | 20 | 14.90 | 1590 | 474 | 3.25 / 190.74 | 5 | 26 |
5 | 13 | 203.40 | 20 | 15.13 | 608 | 184 | 3.43 / 190.92 | 5 | 21 |
6 | 13 | 35.12 | 20 | 15.18 | 360 | 109 | 3.54 / 191.03 | 6 | 20 |
7 | 8 | -0.16 | 242 | 15.13 | 301 | 1102 | 4.64 / 192.13 | 6 | 146 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.12 | 35 | 15.13 | 455 | 241 | 0.24 / 183.03 | 6 | 6 |
2 | 7 | 2010.00 | 40 | 14.69 | 3082 | 1811 | 2.05 / 184.84 | 6 | 14 |
3 | 13 | 1558.28 | 20 | 14.75 | 2491 | 735 | 2.79 / 185.58 | 5 | 20 |
4 | 13 | 984.40 | 20 | 14.88 | 1696 | 505 | 3.29 / 186.08 | 5 | 25 |
5 | 13 | 266.68 | 20 | 15.12 | 699 | 211 | 3.50 / 186.29 | 5 | 22 |
6 | 13 | 38.40 | 20 | 15.18 | 360 | 109 | 3.61 / 186.40 | 6 | 18 |
7 | 8 | 0.00 | 244 | 15.14 | 294 | 1086 | 4.70 / 187.49 | 6 | 179 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.60 | 35 | 15.15 | 459 | 243 | 0.24 / 178.39 | 6 | 6 |
2 | 7 | 2004.08 | 40 | 14.69 | 3078 | 1809 | 2.05 / 180.20 | 6 | 12 |
3 | 13 | 1558.92 | 20 | 14.75 | 2488 | 734 | 2.79 / 180.93 | 5 | 19 |
4 | 13 | 889.08 | 20 | 14.92 | 1579 | 471 | 3.26 / 181.40 | 5 | 26 |
5 | 13 | 207.76 | 20 | 15.14 | 608 | 184 | 3.44 / 181.59 | 5 | 20 |
6 | 13 | 42.20 | 20 | 15.19 | 365 | 111 | 3.55 / 181.70 | 6 | 18 |
7 | 8 | -0.04 | 242 | 15.14 | 299 | 1096 | 4.65 / 182.79 | 6 | 136 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.32 | 35 | 15.14 | 430 | 228 | 0.23 / 173.68 | 6 | 6 |
2 | 7 | 2015.08 | 40 | 14.69 | 3088 | 1815 | 2.04 / 175.49 | 6 | 13 |
3 | 13 | 1473.60 | 20 | 14.77 | 2385 | 705 | 2.75 / 176.20 | 5 | 20 |
4 | 13 | 1028.28 | 20 | 14.87 | 1745 | 519 | 3.27 / 176.72 | 5 | 26 |
5 | 13 | 315.24 | 20 | 15.11 | 764 | 231 | 3.50 / 176.95 | 5 | 22 |
6 | 13 | 51.24 | 20 | 15.19 | 376 | 114 | 3.61 / 177.06 | 6 | 17 |
7 | 8 | 0.12 | 244 | 15.15 | 293 | 1083 | 4.69 / 178.14 | 6 | 155 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.76 | 35 | 15.14 | 447 | 237 | 0.24 / 169.08 | 6 | 6 |
2 | 7 | 2004.28 | 41 | 14.69 | 3094 | 1863 | 2.10 / 170.94 | 6 | 14 |
3 | 13 | 1451.92 | 20 | 14.78 | 2324 | 687 | 2.79 / 171.63 | 5 | 21 |
4 | 13 | 887.00 | 20 | 14.93 | 1544 | 461 | 3.25 / 172.09 | 5 | 26 |
5 | 13 | 183.84 | 20 | 15.16 | 563 | 171 | 3.42 / 172.26 | 5 | 20 |
6 | 13 | 39.16 | 20 | 15.20 | 358 | 109 | 3.53 / 172.37 | 6 | 19 |
7 | 8 | 0.04 | 242 | 15.16 | 294 | 1079 | 4.61 / 173.45 | 6 | 173 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.60 | 35 | 15.15 | 459 | 243 | 0.24 / 164.35 | 6 | 6 |
2 | 7 | 2005.20 | 40 | 14.70 | 3095 | 1820 | 2.06 / 166.17 | 6 | 14 |
3 | 13 | 1458.56 | 20 | 14.79 | 2351 | 695 | 2.76 / 166.86 | 5 | 22 |
4 | 13 | 1011.16 | 20 | 14.88 | 1743 | 519 | 3.28 / 167.38 | 5 | 26 |
5 | 13 | 276.48 | 20 | 15.13 | 713 | 216 | 3.49 / 167.60 | 5 | 23 |
6 | 13 | 69.84 | 20 | 15.19 | 413 | 125 | 3.62 / 167.72 | 5 | 20 |
7 | 8 | 0.08 | 244 | 15.16 | 303 | 1121 | 4.74 / 168.84 | 6 | 166 |
Average= | 4.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.40 | 35 | 15.15 | 450 | 239 | 0.24 / 159.72 | 6 | 6 |
2 | 7 | 2013.48 | 40 | 14.69 | 3090 | 1816 | 2.05 / 161.54 | 6 | 19 |
3 | 13 | 1449.72 | 20 | 14.79 | 2331 | 690 | 2.74 / 162.23 | 5 | 26 |
4 | 13 | 887.92 | 20 | 14.93 | 1568 | 468 | 3.21 / 162.70 | 5 | 32 |
5 | 13 | 197.72 | 20 | 15.16 | 601 | 182 | 3.39 / 162.88 | 5 | 26 |
6 | 13 | 41.76 | 20 | 15.20 | 372 | 113 | 3.51 / 162.99 | 6 | 25 |
7 | 8 | -0.20 | 240 | 15.16 | 306 | 1113 | 4.62 / 164.10 | 6 | 137 |
Average= | 4.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.72 | 35 | 15.15 | 455 | 241 | 0.24 / 155.06 | 6 | 6 |
2 | 7 | 2015.20 | 40 | 14.70 | 3085 | 1814 | 2.06 / 156.88 | 6 | 19 |
3 | 13 | 1454.24 | 20 | 14.79 | 2359 | 698 | 2.75 / 157.58 | 5 | 28 |
4 | 13 | 995.60 | 20 | 14.89 | 1733 | 516 | 3.27 / 158.09 | 5 | 32 |
5 | 13 | 176.40 | 20 | 15.17 | 575 | 174 | 3.44 / 158.27 | 5 | 26 |
6 | 13 | 37.48 | 20 | 15.20 | 368 | 112 | 3.56 / 158.38 | 6 | 25 |
7 | 8 | -0.08 | 240 | 15.16 | 304 | 1106 | 4.66 / 159.48 | 6 | 135 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.48 | 35 | 15.16 | 455 | 241 | 0.24 / 150.33 | 6 | 6 |
2 | 7 | 2003.80 | 40 | 14.71 | 3065 | 1803 | 2.04 / 152.14 | 6 | 20 |
3 | 13 | 1534.72 | 20 | 14.78 | 2432 | 719 | 2.76 / 152.86 | 5 | 27 |
4 | 13 | 1054.56 | 20 | 14.88 | 1819 | 541 | 3.31 / 153.40 | 5 | 32 |
5 | 13 | 211.24 | 20 | 15.17 | 619 | 188 | 3.49 / 153.59 | 5 | 28 |
6 | 13 | 39.84 | 20 | 15.21 | 370 | 113 | 3.61 / 153.70 | 6 | 27 |
7 | 8 | -0.12 | 242 | 15.17 | 306 | 1123 | 4.73 / 154.82 | 6 | 158 |
Average= | 4.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.92 | 35 | 15.15 | 470 | 249 | 0.25 / 145.71 | 6 | 6 |
2 | 7 | 2005.72 | 40 | 14.71 | 3066 | 1804 | 2.05 / 147.51 | 6 | 19 |
3 | 13 | 1446.20 | 20 | 14.81 | 2316 | 686 | 2.74 / 148.20 | 5 | 27 |
4 | 13 | 1001.24 | 20 | 14.90 | 1725 | 514 | 3.25 / 148.71 | 5 | 32 |
5 | 13 | 184.36 | 20 | 15.18 | 579 | 176 | 3.43 / 148.89 | 5 | 26 |
6 | 13 | 34.00 | 20 | 15.22 | 357 | 109 | 3.54 / 149.00 | 6 | 26 |
7 | 8 | -0.04 | 242 | 15.17 | 299 | 1098 | 4.64 / 150.09 | 6 | 158 |
Average= | 4.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.56 | 35 | 15.16 | 463 | 246 | 0.25 / 140.95 | 6 | 6 |
2 | 7 | 2017.92 | 40 | 14.70 | 3087 | 1815 | 2.06 / 142.76 | 6 | 19 |
3 | 13 | 1461.04 | 20 | 14.80 | 2383 | 705 | 2.77 / 143.47 | 5 | 27 |
4 | 13 | 1007.32 | 20 | 14.89 | 1753 | 522 | 3.29 / 143.99 | 5 | 32 |
5 | 13 | 274.76 | 20 | 15.15 | 717 | 217 | 3.51 / 144.21 | 5 | 29 |
6 | 13 | 30.40 | 20 | 15.21 | 358 | 109 | 3.61 / 144.32 | 6 | 27 |
7 | 8 | -0.08 | 242 | 15.17 | 311 | 1142 | 4.76 / 145.46 | 6 | 144 |
Average= | 4.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.64 | 35 | 15.17 | 459 | 244 | 0.24 / 136.33 | 6 | 6 |
2 | 7 | 2017.00 | 40 | 14.71 | 3080 | 1812 | 2.06 / 138.14 | 6 | 19 |
3 | 13 | 1450.36 | 20 | 14.81 | 2342 | 694 | 2.75 / 138.83 | 5 | 27 |
4 | 13 | 867.16 | 20 | 14.96 | 1543 | 462 | 3.21 / 139.29 | 5 | 32 |
5 | 13 | 170.76 | 20 | 15.19 | 569 | 173 | 3.38 / 139.47 | 5 | 27 |
6 | 13 | 35.60 | 20 | 15.22 | 370 | 113 | 3.50 / 139.58 | 6 | 26 |
7 | 8 | 0.04 | 240 | 15.18 | 308 | 1122 | 4.62 / 140.70 | 6 | 144 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.84 | 35 | 15.17 | 472 | 251 | 0.25 / 131.64 | 6 | 6 |
2 | 7 | 2004.32 | 40 | 14.72 | 3087 | 1818 | 2.07 / 133.46 | 6 | 16 |
3 | 13 | 1464.20 | 20 | 14.81 | 2355 | 698 | 2.77 / 134.16 | 5 | 25 |
4 | 13 | 914.04 | 20 | 14.95 | 1604 | 480 | 3.25 / 134.64 | 5 | 30 |
5 | 13 | 207.04 | 20 | 15.18 | 618 | 188 | 3.43 / 134.83 | 5 | 25 |
6 | 13 | 38.76 | 20 | 15.22 | 376 | 114 | 3.55 / 134.94 | 6 | 25 |
7 | 8 | -0.20 | 242 | 15.18 | 311 | 1142 | 4.69 / 136.08 | 6 | 161 |
Average= | 4.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.76 | 35 | 15.17 | 463 | 246 | 0.25 / 126.93 | 6 | 6 |
2 | 7 | 2004.16 | 40 | 14.72 | 3084 | 1816 | 2.06 / 128.75 | 6 | 15 |
3 | 13 | 1534.52 | 20 | 14.80 | 2456 | 727 | 2.79 / 129.47 | 5 | 22 |
4 | 13 | 945.00 | 20 | 14.94 | 1668 | 498 | 3.29 / 129.97 | 5 | 28 |
5 | 13 | 220.32 | 20 | 15.18 | 641 | 195 | 3.48 / 130.17 | 5 | 23 |
6 | 13 | 21.36 | 20 | 15.23 | 349 | 106 | 3.59 / 130.27 | 6 | 23 |
7 | 8 | 0.12 | 240 | 15.19 | 307 | 1119 | 4.71 / 131.39 | 6 | 142 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.08 | 35 | 15.18 | 463 | 246 | 0.25 / 122.12 | 6 | 6 |
2 | 7 | 2007.04 | 41 | 14.72 | 3089 | 1864 | 2.11 / 123.98 | 6 | 18 |
3 | 13 | 1544.36 | 20 | 14.80 | 2463 | 729 | 2.84 / 124.71 | 5 | 26 |
4 | 13 | 959.32 | 20 | 14.94 | 1695 | 506 | 3.35 / 125.22 | 5 | 31 |
5 | 13 | 234.32 | 20 | 15.18 | 664 | 202 | 3.55 / 125.42 | 5 | 26 |
6 | 13 | 21.80 | 20 | 15.24 | 357 | 109 | 3.66 / 125.53 | 6 | 24 |
7 | 8 | 0.12 | 240 | 15.19 | 317 | 1156 | 4.81 / 126.69 | 6 | 141 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.48 | 35 | 15.18 | 460 | 244 | 0.24 / 117.45 | 6 | 6 |
2 | 7 | 2004.76 | 40 | 14.74 | 3070 | 1810 | 2.05 / 119.26 | 6 | 19 |
3 | 13 | 1469.12 | 20 | 14.82 | 2380 | 705 | 2.76 / 119.97 | 5 | 26 |
4 | 13 | 909.64 | 20 | 14.96 | 1620 | 485 | 3.24 / 120.45 | 5 | 31 |
5 | 13 | 192.36 | 20 | 15.20 | 606 | 184 | 3.43 / 120.63 | 5 | 26 |
6 | 13 | 30.88 | 20 | 15.24 | 360 | 110 | 3.54 / 120.74 | 6 | 26 |
7 | 8 | -0.16 | 240 | 15.19 | 310 | 1130 | 4.67 / 121.87 | 6 | 139 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.16 | 35 | 15.18 | 461 | 245 | 0.24 / 112.65 | 6 | 6 |
2 | 7 | 2006.68 | 40 | 14.73 | 3089 | 1820 | 2.06 / 114.47 | 6 | 18 |
3 | 13 | 1568.92 | 20 | 14.81 | 2499 | 740 | 2.81 / 115.21 | 5 | 25 |
4 | 13 | 1088.60 | 20 | 14.90 | 1841 | 549 | 3.35 / 115.76 | 5 | 31 |
5 | 13 | 222.12 | 20 | 15.19 | 648 | 197 | 3.55 / 115.96 | 5 | 27 |
6 | 13 | 20.24 | 20 | 15.24 | 345 | 105 | 3.66 / 116.06 | 6 | 26 |
7 | 8 | 0.04 | 242 | 15.20 | 311 | 1144 | 4.80 / 117.21 | 6 | 163 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.32 | 35 | 15.18 | 468 | 249 | 0.25 / 107.97 | 6 | 7 |
2 | 7 | 2005.56 | 40 | 14.74 | 3078 | 1815 | 2.06 / 109.79 | 7 | 18 |
3 | 13 | 1480.32 | 20 | 14.84 | 2343 | 695 | 2.76 / 110.48 | 5 | 27 |
4 | 13 | 1016.72 | 20 | 14.92 | 1754 | 523 | 3.28 / 111.00 | 5 | 31 |
5 | 13 | 190.36 | 20 | 15.20 | 590 | 179 | 3.46 / 111.18 | 5 | 26 |
6 | 8 | -0.12 | 261 | 15.20 | 308 | 1222 | 4.68 / 112.41 | 6 | 154 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.28 | 35 | 15.19 | 460 | 245 | 0.24 / 103.27 | 6 | 7 |
2 | 7 | 2004.64 | 41 | 14.74 | 3064 | 1852 | 2.10 / 105.12 | 7 | 19 |
3 | 13 | 1445.04 | 20 | 14.85 | 2329 | 692 | 2.79 / 105.81 | 5 | 27 |
4 | 13 | 986.76 | 20 | 14.94 | 1709 | 511 | 3.30 / 106.32 | 5 | 32 |
5 | 13 | 129.08 | 20 | 15.22 | 525 | 160 | 3.46 / 106.48 | 5 | 27 |
6 | 8 | 0.00 | 259 | 15.20 | 315 | 1240 | 4.70 / 107.72 | 6 | 145 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.68 | 35 | 15.19 | 459 | 244 | 0.24 / 98.61 | 6 | 7 |
2 | 7 | 2014.40 | 40 | 14.75 | 3090 | 1823 | 2.07 / 100.44 | 7 | 19 |
3 | 13 | 1542.80 | 20 | 14.83 | 2446 | 725 | 2.79 / 101.16 | 5 | 27 |
4 | 13 | 866.08 | 20 | 14.99 | 1546 | 463 | 3.26 / 101.63 | 5 | 32 |
5 | 13 | 174.52 | 20 | 15.22 | 572 | 174 | 3.43 / 101.80 | 5 | 27 |
6 | 8 | 0.20 | 261 | 15.21 | 308 | 1223 | 4.65 / 103.02 | 6 | 163 |
Average= | 4.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.12 | 35 | 15.18 | 460 | 244 | 0.24 / 94.03 | 6 | 7 |
2 | 7 | 2004.00 | 41 | 14.75 | 3078 | 1861 | 2.11 / 95.89 | 7 | 19 |
3 | 13 | 1355.60 | 20 | 14.88 | 2192 | 652 | 2.76 / 96.54 | 5 | 29 |
4 | 13 | 831.16 | 20 | 15.01 | 1486 | 446 | 3.20 / 96.99 | 5 | 33 |
5 | 13 | 125.52 | 20 | 15.23 | 501 | 153 | 3.36 / 97.14 | 6 | 27 |
6 | 8 | 0.04 | 259 | 15.21 | 312 | 1229 | 4.59 / 98.37 | 6 | 145 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.12 | 35 | 15.20 | 458 | 244 | 0.24 / 89.33 | 6 | 7 |
2 | 7 | 2016.76 | 40 | 14.76 | 3073 | 1814 | 2.06 / 91.14 | 7 | 20 |
3 | 13 | 1463.84 | 20 | 14.85 | 2370 | 704 | 2.76 / 91.85 | 5 | 28 |
4 | 13 | 908.84 | 20 | 14.98 | 1607 | 481 | 3.24 / 92.33 | 5 | 33 |
5 | 13 | 300.28 | 20 | 15.18 | 749 | 227 | 3.47 / 92.55 | 5 | 29 |
6 | 8 | -0.04 | 261 | 15.21 | 310 | 1231 | 4.70 / 93.78 | 6 | 157 |
Average= | 4.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.40 | 35 | 15.20 | 466 | 248 | 0.25 / 84.61 | 6 | 7 |
2 | 7 | 2013.56 | 40 | 14.75 | 3104 | 1831 | 2.08 / 86.44 | 7 | 19 |
3 | 13 | 1465.72 | 20 | 14.85 | 2371 | 704 | 2.78 / 87.14 | 5 | 28 |
4 | 13 | 1014.64 | 20 | 14.95 | 1743 | 521 | 3.30 / 87.67 | 5 | 33 |
5 | 13 | 187.60 | 20 | 15.22 | 598 | 182 | 3.49 / 87.85 | 5 | 27 |
6 | 8 | 0.12 | 261 | 15.22 | 311 | 1235 | 4.72 / 89.08 | 6 | 166 |
Average= | 4.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.84 | 35 | 15.20 | 473 | 252 | 0.25 / 79.80 | 6 | 8 |
2 | 7 | 2016.52 | 40 | 14.76 | 3095 | 1827 | 2.08 / 81.63 | 8 | 19 |
3 | 13 | 1555.56 | 20 | 14.84 | 2481 | 736 | 2.82 / 82.37 | 5 | 27 |
4 | 13 | 976.12 | 20 | 14.97 | 1696 | 508 | 3.32 / 82.88 | 5 | 33 |
5 | 13 | 259.36 | 20 | 15.20 | 701 | 213 | 3.54 / 83.09 | 5 | 28 |
6 | 13 | 23.20 | 20 | 15.26 | 358 | 109 | 3.65 / 83.20 | 6 | 27 |
7 | 8 | 0.00 | 242 | 15.21 | 316 | 1163 | 4.81 / 84.36 | 6 | 167 |
Average= | 4.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.24 | 35 | 15.20 | 472 | 251 | 0.25 / 75.12 | 6 | 8 |
2 | 7 | 2008.68 | 40 | 14.77 | 3064 | 1810 | 2.06 / 76.93 | 8 | 20 |
3 | 13 | 1528.08 | 20 | 14.85 | 2426 | 721 | 2.78 / 77.65 | 5 | 28 |
4 | 13 | 928.80 | 20 | 14.99 | 1635 | 490 | 3.27 / 78.14 | 5 | 33 |
5 | 13 | 105.20 | 20 | 15.25 | 480 | 146 | 3.42 / 78.29 | 5 | 27 |
6 | 8 | 0.20 | 259 | 15.22 | 320 | 1261 | 4.68 / 79.55 | 6 | 147 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.76 | 34 | 15.22 | 438 | 227 | 0.23 / 70.42 | 6 | 8 |
2 | 7 | 2004.52 | 41 | 14.76 | 3084 | 1866 | 2.09 / 72.29 | 8 | 20 |
3 | 13 | 1555.12 | 20 | 14.85 | 2475 | 735 | 2.83 / 73.03 | 5 | 27 |
4 | 13 | 860.08 | 20 | 15.02 | 1524 | 458 | 3.29 / 73.48 | 5 | 33 |
5 | 13 | 139.00 | 20 | 15.25 | 508 | 155 | 3.44 / 73.64 | 5 | 28 |
6 | 8 | -0.08 | 259 | 15.23 | 313 | 1235 | 4.68 / 74.87 | 6 | 152 |
Average= | 4.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.68 | 34 | 15.22 | 440 | 228 | 0.23 / 65.95 | 6 | 8 |
2 | 7 | 2006.60 | 41 | 14.77 | 3078 | 1864 | 2.09 / 67.82 | 8 | 20 |
3 | 13 | 1351.04 | 20 | 14.91 | 2186 | 652 | 2.74 / 68.47 | 5 | 30 |
4 | 13 | 909.76 | 20 | 15.00 | 1593 | 478 | 3.22 / 68.94 | 5 | 34 |
5 | 13 | 93.36 | 20 | 15.27 | 433 | 132 | 3.35 / 69.08 | 6 | 26 |
6 | 8 | 0.12 | 257 | 15.24 | 286 | 1120 | 4.47 / 70.20 | 6 | 149 |
Average= | 4.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.68 | 34 | 15.22 | 433 | 224 | 0.22 / 61.34 | 6 | 7 |
2 | 7 | 2006.20 | 40 | 14.78 | 3086 | 1824 | 2.05 / 63.16 | 7 | 19 |
3 | 13 | 1541.80 | 20 | 14.86 | 2447 | 727 | 2.78 / 63.89 | 5 | 28 |
4 | 13 | 971.24 | 20 | 14.99 | 1672 | 501 | 3.28 / 64.39 | 5 | 33 |
5 | 13 | 232.20 | 20 | 15.22 | 643 | 196 | 3.47 / 64.59 | 5 | 29 |
6 | 8 | -0.08 | 259 | 15.24 | 288 | 1137 | 4.61 / 65.72 | 6 | 142 |
Average= | 4.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.08 | 34 | 15.23 | 431 | 223 | 0.22 / 56.82 | 6 | 7 |
2 | 7 | 2018.48 | 40 | 14.79 | 3072 | 1817 | 2.04 / 58.64 | 7 | 20 |
3 | 13 | 1473.00 | 20 | 14.88 | 2345 | 698 | 2.74 / 59.34 | 5 | 28 |
4 | 13 | 909.28 | 20 | 15.02 | 1587 | 477 | 3.22 / 59.82 | 5 | 33 |
5 | 13 | 189.28 | 20 | 15.24 | 575 | 175 | 3.39 / 59.99 | 5 | 27 |
6 | 8 | 0.04 | 259 | 15.25 | 284 | 1122 | 4.51 / 61.11 | 6 | 152 |
Average= | 4.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.32 | 34 | 15.22 | 452 | 234 | 0.23 / 52.31 | 6 | 8 |
2 | 7 | 2012.48 | 40 | 14.78 | 3088 | 1826 | 2.06 / 54.14 | 8 | 19 |
3 | 13 | 1448.12 | 20 | 14.89 | 2348 | 699 | 2.76 / 54.84 | 5 | 28 |
4 | 13 | 884.84 | 20 | 15.02 | 1556 | 467 | 3.23 / 55.30 | 5 | 32 |
5 | 13 | 162.52 | 20 | 15.26 | 537 | 164 | 3.39 / 55.47 | 6 | 27 |
6 | 8 | 0.08 | 259 | 15.25 | 287 | 1134 | 4.52 / 56.60 | 6 | 161 |
Average= | 4.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.20 | 34 | 15.24 | 432 | 224 | 0.22 / 47.79 | 6 | 7 |
2 | 7 | 2016.80 | 41 | 14.80 | 3063 | 1859 | 2.08 / 49.65 | 7 | 20 |
3 | 13 | 1450.96 | 20 | 14.89 | 2322 | 691 | 2.77 / 50.34 | 5 | 28 |
4 | 13 | 876.72 | 20 | 15.04 | 1525 | 459 | 3.23 / 50.80 | 5 | 32 |
5 | 13 | 156.88 | 20 | 15.26 | 528 | 161 | 3.39 / 50.96 | 5 | 27 |
6 | 8 | 0.00 | 257 | 15.25 | 285 | 1117 | 4.51 / 52.08 | 6 | 135 |
Average= | 4.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.08 | 34 | 15.23 | 445 | 230 | 0.23 / 43.28 | 6 | 8 |
2 | 7 | 2014.40 | 41 | 14.79 | 3092 | 1875 | 2.11 / 45.15 | 8 | 19 |
3 | 13 | 1459.60 | 20 | 14.90 | 2328 | 694 | 2.80 / 45.85 | 5 | 27 |
4 | 13 | 887.16 | 20 | 15.03 | 1550 | 466 | 3.27 / 46.31 | 5 | 33 |
5 | 13 | 96.32 | 20 | 15.28 | 436 | 133 | 3.40 / 46.45 | 6 | 25 |
6 | 8 | 0.24 | 259 | 15.25 | 284 | 1122 | 4.52 / 47.57 | 6 | 170 |
Average= | 3.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.88 | 34 | 15.24 | 439 | 227 | 0.23 / 38.77 | 6 | 7 |
2 | 7 | 2004.40 | 40 | 14.81 | 3051 | 1807 | 2.03 / 40.58 | 7 | 20 |
3 | 13 | 1523.80 | 20 | 14.88 | 2448 | 729 | 2.76 / 41.31 | 5 | 27 |
4 | 13 | 937.04 | 20 | 15.02 | 1611 | 484 | 3.25 / 41.79 | 5 | 33 |
5 | 13 | 100.52 | 20 | 15.28 | 443 | 135 | 3.38 / 41.93 | 5 | 26 |
6 | 8 | 0.00 | 257 | 15.26 | 286 | 1122 | 4.50 / 43.05 | 6 | 131 |
Average= | 3.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.48 | 34 | 15.25 | 435 | 226 | 0.23 / 34.26 | 6 | 6 |
2 | 7 | 2010.00 | 40 | 14.80 | 3079 | 1823 | 2.05 / 36.09 | 6 | 19 |
3 | 13 | 1462.04 | 20 | 14.90 | 2353 | 701 | 2.75 / 36.79 | 5 | 28 |
4 | 13 | 882.88 | 20 | 15.03 | 1561 | 469 | 3.22 / 37.26 | 5 | 32 |
5 | 13 | 168.80 | 20 | 15.26 | 545 | 166 | 3.39 / 37.42 | 5 | 27 |
6 | 8 | -0.08 | 259 | 15.26 | 283 | 1119 | 4.50 / 38.54 | 6 | 158 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.52 | 34 | 15.25 | 440 | 228 | 0.23 / 29.78 | 6 | 6 |
2 | 7 | 2007.04 | 41 | 14.81 | 3065 | 1861 | 2.09 / 31.64 | 6 | 19 |
3 | 13 | 1452.64 | 20 | 14.91 | 2322 | 692 | 2.78 / 32.34 | 5 | 28 |
4 | 13 | 873.16 | 20 | 15.04 | 1548 | 466 | 3.25 / 32.80 | 5 | 33 |
5 | 13 | 92.96 | 20 | 15.29 | 430 | 131 | 3.38 / 32.93 | 6 | 25 |
6 | 8 | 0.00 | 257 | 15.26 | 282 | 1106 | 4.48 / 34.04 | 6 | 141 |
Average= | 3.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.32 | 34 | 15.25 | 438 | 227 | 0.23 / 25.28 | 6 | 6 |
2 | 7 | 2005.84 | 40 | 14.81 | 3088 | 1829 | 2.06 / 27.11 | 8 | 19 |
3 | 13 | 1438.28 | 20 | 14.91 | 2320 | 692 | 2.75 / 27.80 | 5 | 28 |
4 | 13 | 964.36 | 20 | 15.01 | 1674 | 503 | 3.25 / 28.30 | 5 | 32 |
5 | 13 | 120.60 | 20 | 15.28 | 472 | 144 | 3.40 / 28.44 | 6 | 25 |
6 | 8 | 0.20 | 257 | 15.27 | 283 | 1111 | 4.51 / 29.55 | 6 | 133 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.92 | 33 | 15.25 | 429 | 216 | 0.22 / 20.75 | 6 | 6 |
2 | 3 | 1036.96 | 1 | 15.25 | 1741 | 27 | 0.24 / 20.78 | 5 | 16 |
3 | 7 | 2015.60 | 40 | 14.81 | 3072 | 1820 | 2.06 / 22.60 | 16 | 20 |
4 | 13 | 1545.68 | 20 | 14.89 | 2456 | 731 | 2.79 / 23.33 | 5 | 27 |
5 | 13 | 870.88 | 20 | 15.05 | 1547 | 466 | 3.26 / 23.80 | 5 | 32 |
6 | 13 | 104.12 | 20 | 15.29 | 448 | 137 | 3.40 / 23.93 | 6 | 24 |
7 | 13 | 22.60 | 20 | 15.31 | 323 | 99 | 3.50 / 24.03 | 6 | 24 |
8 | 8 | 0.04 | 238 | 15.27 | 280 | 1018 | 4.51 / 25.05 | 6 | 129 |
Average= | 3.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.72 | 31 | 15.26 | 441 | 209 | 0.21 / 16.17 | 6 | 6 |
2 | 3 | 1076.76 | 2 | 15.22 | 1810 | 55 | 0.26 / 16.22 | 5 | 20 |
3 | 7 | 2017.20 | 40 | 14.82 | 3091 | 1832 | 2.10 / 18.05 | 20 | 19 |
4 | 13 | 1461.60 | 20 | 14.92 | 2332 | 696 | 2.79 / 18.75 | 5 | 27 |
5 | 13 | 989.92 | 20 | 15.01 | 1703 | 511 | 3.30 / 19.26 | 5 | 32 |
6 | 13 | 146.36 | 20 | 15.27 | 511 | 156 | 3.46 / 19.42 | 5 | 26 |
7 | 8 | 0.16 | 259 | 15.27 | 283 | 1119 | 4.58 / 20.54 | 6 | 145 |
Average= | 3.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.12 | 33 | 15.26 | 435 | 219 | 0.22 / 12.28 | 6 | 6 |
2 | 7 | 1516.36 | 40 | 15.02 | 2405 | 1445 | 1.66 / 13.72 | 6 | 20 |
3 | 13 | 1320.92 | 20 | 15.02 | 2141 | 643 | 2.31 / 14.36 | 5 | 25 |
4 | 13 | 728.00 | 20 | 15.14 | 1328 | 402 | 2.71 / 14.77 | 5 | 29 |
5 | 13 | 60.96 | 20 | 15.32 | 376 | 115 | 2.82 / 14.88 | 6 | 24 |
6 | 8 | 0.00 | 253 | 15.29 | 278 | 1075 | 3.90 / 15.96 | 6 | 147 |
Average= | 3.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.40 | 32 | 15.25 | 429 | 209 | 0.21 / 8.23 | 6 | 6 |
2 | 3 | 1037.24 | 1 | 15.25 | 1750 | 27 | 0.24 / 8.26 | 5 | 17 |
3 | 7 | 1506.40 | 41 | 15.02 | 2386 | 1469 | 1.71 / 9.73 | 17 | 20 |
4 | 13 | 1411.00 | 20 | 15.01 | 2265 | 680 | 2.39 / 10.41 | 5 | 24 |
5 | 13 | 796.76 | 20 | 15.12 | 1432 | 433 | 2.82 / 10.84 | 5 | 29 |
6 | 13 | 76.00 | 20 | 15.31 | 401 | 123 | 2.94 / 10.96 | 6 | 24 |
7 | 8 | -0.08 | 255 | 15.28 | 281 | 1095 | 4.04 / 12.06 | 6 | 158 |
Average= | 3.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.28 | 31 | 15.27 | 432 | 204 | 0.20 / 4.24 | 6 | 6 |
2 | 10 | 1002.92 | 3 | 15.22 | 1716 | 78 | 0.28 / 4.31 | 6 | 11 |
3 | 3 | 955.08 | -1 | 15.56 | 5 | 0 | 0.08 / 4.31 | 6 | 11 |
4 | 7 | 1528.20 | 40 | 15.01 | 2420 | 1453 | 1.74 / 5.77 | 11 | 20 |
5 | 13 | 1335.52 | 20 | 15.01 | 2157 | 648 | 2.38 / 6.42 | 5 | 25 |
6 | 13 | 741.12 | 20 | 15.13 | 1348 | 408 | 2.79 / 6.82 | 5 | 29 |
7 | 13 | 68.80 | 20 | 15.31 | 390 | 119 | 2.91 / 6.94 | 6 | 24 |
8 | 8 | 0.12 | 255 | 15.28 | 277 | 1079 | 3.99 / 8.02 | 6 | 149 |
Average= | 2.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.48 | 31 | 15.42 | 417 | 199 | 0.20 / 1.76 | 6 | 6 |
2 | 3 | 1037.12 | 1 | 15.25 | 1773 | 27 | 0.23 / 1.79 | 5 | 17 |
3 | 7 | 1009.20 | 40 | 15.15 | 1727 | 1047 | 1.27 / 2.83 | 17 | 24 |
4 | 13 | 67.20 | 20 | 15.35 | 389 | 119 | 1.39 / 2.95 | 6 | 22 |
5 | 8 | 0.16 | 255 | 15.32 | 276 | 1078 | 2.47 / 4.03 | 6 | 144 |
Average= | 2.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 145.88 | 30 | 15.58 | 466 | 218 | 0.22 / 0.22 | 6 | 6 |
2 | 7 | 160.16 | 40 | 15.55 | 479 | 298 | 0.52 / 0.52 | 6 | 8 |
3 | 13 | 47.96 | 20 | 15.55 | 321 | 100 | 0.62 / 0.62 | 6 | 9 |
4 | 8 | 0.20 | 250 | 15.50 | 244 | 945 | 1.56 / 1.56 | 6 | 198 |
Average= | 1.56 (KJ/cycle) |