SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.32 | 29 | 15.08 | 444 | 194 | 0.19 / 298.85 | 5 | 5 |
2 | 7 | 2003.08 | 41 | 14.72 | 3448 | 2081 | 2.28 / 300.93 | 5 | 17 |
3 | 13 | 1292.92 | 20 | 14.80 | 2383 | 705 | 2.98 / 301.63 | 4 | 28 |
4 | 13 | 719.20 | 20 | 14.93 | 1467 | 438 | 3.42 / 302.07 | 4 | 27 |
5 | 13 | 108.16 | 20 | 15.09 | 484 | 146 | 3.56 / 302.22 | 5 | 27 |
6 | 13 | 62.52 | 20 | 15.10 | 401 | 121 | 3.69 / 302.34 | 5 | 19 |
7 | 13 | 15.40 | 20 | 15.11 | 320 | 97 | 3.78 / 302.43 | 5 | 20 |
8 | 8 | -0.04 | 240 | 15.07 | 289 | 1045 | 4.83 / 303.48 | 5 | 167 |
Average= | 7.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.64 | 29 | 15.07 | 430 | 188 | 0.19 / 294.13 | 5 | 5 |
2 | 7 | 2009.96 | 40 | 14.72 | 3457 | 2035 | 2.22 / 296.17 | 5 | 22 |
3 | 13 | 1316.60 | 20 | 14.80 | 2417 | 715 | 2.94 / 296.88 | 4 | 29 |
4 | 13 | 622.16 | 20 | 14.96 | 1314 | 393 | 3.33 / 297.28 | 4 | 29 |
5 | 13 | 101.60 | 20 | 15.10 | 472 | 143 | 3.47 / 297.42 | 5 | 24 |
6 | 13 | 65.80 | 20 | 15.11 | 408 | 123 | 3.60 / 297.54 | 5 | 25 |
7 | 8 | 0.04 | 259 | 15.08 | 284 | 1109 | 4.71 / 298.65 | 5 | 143 |
Average= | 7.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.68 | 29 | 15.08 | 435 | 190 | 0.19 / 289.42 | 5 | 6 |
2 | 7 | 2012.96 | 40 | 14.72 | 3464 | 2040 | 2.23 / 291.46 | 6 | 21 |
3 | 13 | 1217.08 | 20 | 14.83 | 2254 | 669 | 2.90 / 292.13 | 4 | 27 |
4 | 13 | 648.56 | 20 | 14.96 | 1353 | 405 | 3.30 / 292.53 | 4 | 27 |
5 | 13 | 168.48 | 20 | 15.08 | 579 | 175 | 3.48 / 292.71 | 5 | 28 |
6 | 13 | 87.24 | 20 | 15.10 | 439 | 133 | 3.61 / 292.84 | 5 | 25 |
7 | 8 | 0.08 | 257 | 15.08 | 285 | 1105 | 4.71 / 293.94 | 5 | 130 |
Average= | 7.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.28 | 29 | 15.08 | 449 | 196 | 0.20 / 284.64 | 5 | 5 |
2 | 7 | 2003.28 | 40 | 14.73 | 3456 | 2036 | 2.23 / 286.67 | 5 | 18 |
3 | 13 | 1309.24 | 20 | 14.82 | 2400 | 711 | 2.94 / 287.38 | 4 | 26 |
4 | 13 | 713.44 | 20 | 14.95 | 1448 | 433 | 3.38 / 287.82 | 4 | 28 |
5 | 13 | 125.52 | 20 | 15.11 | 508 | 154 | 3.53 / 287.97 | 5 | 28 |
6 | 13 | 71.16 | 20 | 15.11 | 417 | 126 | 3.66 / 288.10 | 5 | 25 |
7 | 8 | 0.08 | 259 | 15.09 | 290 | 1133 | 4.79 / 289.23 | 5 | 145 |
Average= | 7.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.68 | 29 | 15.09 | 430 | 188 | 0.19 / 279.89 | 5 | 5 |
2 | 7 | 2014.04 | 40 | 14.73 | 3463 | 2040 | 2.23 / 281.93 | 5 | 20 |
3 | 13 | 1323.68 | 20 | 14.81 | 2418 | 716 | 2.94 / 282.64 | 4 | 26 |
4 | 13 | 628.36 | 20 | 14.98 | 1319 | 395 | 3.34 / 283.04 | 5 | 30 |
5 | 13 | 148.04 | 20 | 15.10 | 553 | 167 | 3.51 / 283.20 | 5 | 25 |
6 | 13 | 44.68 | 20 | 15.13 | 367 | 111 | 3.62 / 283.32 | 5 | 26 |
7 | 8 | -0.04 | 257 | 15.09 | 290 | 1125 | 4.74 / 284.44 | 5 | 131 |
Average= | 7.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.60 | 29 | 15.09 | 454 | 199 | 0.20 / 275.18 | 5 | 5 |
2 | 7 | 2004.88 | 40 | 14.73 | 3437 | 2025 | 2.22 / 277.20 | 5 | 18 |
3 | 13 | 1298.12 | 20 | 14.82 | 2381 | 706 | 2.93 / 277.91 | 4 | 25 |
4 | 13 | 595.36 | 20 | 14.99 | 1263 | 379 | 3.31 / 278.29 | 4 | 30 |
5 | 13 | 126.36 | 20 | 15.11 | 516 | 156 | 3.46 / 278.44 | 5 | 25 |
6 | 13 | 73.52 | 20 | 15.12 | 422 | 128 | 3.59 / 278.57 | 5 | 22 |
7 | 8 | -0.04 | 257 | 15.09 | 290 | 1125 | 4.72 / 279.70 | 5 | 139 |
Average= | 7.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.96 | 29 | 15.10 | 451 | 197 | 0.20 / 270.47 | 5 | 5 |
2 | 7 | 2005.92 | 40 | 14.74 | 3448 | 2033 | 2.23 / 272.51 | 5 | 20 |
3 | 13 | 1284.60 | 20 | 14.84 | 2355 | 699 | 2.93 / 273.20 | 4 | 27 |
4 | 13 | 599.12 | 20 | 15.00 | 1273 | 382 | 3.31 / 273.59 | 4 | 28 |
5 | 13 | 134.68 | 20 | 15.12 | 526 | 159 | 3.47 / 273.75 | 5 | 26 |
6 | 13 | 38.76 | 20 | 15.14 | 362 | 110 | 3.58 / 273.86 | 5 | 21 |
7 | 8 | -0.12 | 257 | 15.10 | 290 | 1125 | 4.71 / 274.98 | 5 | 149 |
Average= | 7.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.60 | 29 | 15.11 | 454 | 199 | 0.20 / 265.73 | 5 | 6 |
2 | 7 | 2006.84 | 40 | 14.75 | 3456 | 2039 | 2.24 / 267.77 | 6 | 19 |
3 | 13 | 1225.92 | 20 | 14.86 | 2275 | 676 | 2.91 / 268.44 | 4 | 26 |
4 | 13 | 657.60 | 20 | 14.98 | 1374 | 412 | 3.33 / 268.85 | 5 | 29 |
5 | 13 | 166.44 | 20 | 15.11 | 582 | 176 | 3.50 / 269.03 | 5 | 24 |
6 | 13 | 42.40 | 20 | 15.14 | 372 | 113 | 3.61 / 269.14 | 5 | 25 |
7 | 8 | 0.00 | 257 | 15.11 | 292 | 1134 | 4.75 / 270.28 | 5 | 132 |
Average= | 7.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.12 | 29 | 15.11 | 448 | 196 | 0.20 / 261.04 | 5 | 6 |
2 | 7 | 2014.36 | 40 | 14.74 | 3476 | 2049 | 2.25 / 263.09 | 6 | 19 |
3 | 13 | 1242.76 | 20 | 14.85 | 2297 | 682 | 2.93 / 263.77 | 4 | 27 |
4 | 13 | 564.96 | 20 | 15.01 | 1227 | 368 | 3.30 / 264.14 | 5 | 24 |
5 | 13 | 121.28 | 20 | 15.13 | 506 | 153 | 3.45 / 264.29 | 5 | 24 |
6 | 13 | 32.48 | 20 | 15.15 | 353 | 107 | 3.56 / 264.40 | 5 | 23 |
7 | 8 | 0.04 | 257 | 15.11 | 291 | 1130 | 4.69 / 265.53 | 5 | 139 |
Average= | 7.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.56 | 29 | 15.12 | 451 | 198 | 0.20 / 256.24 | 5 | 5 |
2 | 7 | 2012.60 | 40 | 14.75 | 3461 | 2042 | 2.24 / 258.28 | 5 | 19 |
3 | 13 | 1316.28 | 20 | 14.84 | 2407 | 714 | 2.95 / 258.99 | 4 | 28 |
4 | 13 | 722.48 | 20 | 14.98 | 1465 | 439 | 3.39 / 259.43 | 5 | 33 |
5 | 13 | 125.40 | 20 | 15.14 | 513 | 155 | 3.55 / 259.59 | 5 | 27 |
6 | 13 | 39.72 | 20 | 15.16 | 362 | 110 | 3.66 / 259.70 | 5 | 20 |
7 | 8 | 0.04 | 259 | 15.12 | 292 | 1143 | 4.80 / 260.84 | 5 | 157 |
Average= | 7.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.60 | 29 | 15.12 | 455 | 200 | 0.20 / 251.43 | 5 | 5 |
2 | 7 | 2004.32 | 41 | 14.75 | 3460 | 2092 | 2.29 / 253.52 | 5 | 20 |
3 | 13 | 1294.20 | 20 | 14.85 | 2387 | 709 | 3.00 / 254.23 | 4 | 23 |
4 | 13 | 706.36 | 20 | 14.99 | 1444 | 433 | 3.43 / 254.66 | 4 | 28 |
5 | 13 | 121.24 | 20 | 15.15 | 504 | 153 | 3.59 / 254.82 | 5 | 30 |
6 | 13 | 44.72 | 20 | 15.16 | 370 | 112 | 3.70 / 254.93 | 5 | 15 |
7 | 8 | -0.08 | 255 | 15.13 | 288 | 1111 | 4.81 / 256.04 | 5 | 130 |
Average= | 8.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.24 | 29 | 15.13 | 425 | 186 | 0.19 / 246.78 | 5 | 6 |
2 | 7 | 2003.08 | 40 | 14.75 | 3458 | 2040 | 2.23 / 248.82 | 6 | 19 |
3 | 13 | 1218.16 | 20 | 14.87 | 2255 | 671 | 2.90 / 249.49 | 4 | 28 |
4 | 13 | 546.84 | 20 | 15.04 | 1190 | 358 | 3.26 / 249.84 | 5 | 30 |
5 | 13 | 110.68 | 20 | 15.15 | 489 | 148 | 3.40 / 249.99 | 5 | 25 |
6 | 13 | 34.88 | 20 | 15.16 | 359 | 109 | 3.51 / 250.10 | 5 | 23 |
7 | 8 | -0.04 | 257 | 15.13 | 290 | 1128 | 4.64 / 251.23 | 5 | 146 |
Average= | 8.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.72 | 29 | 15.13 | 430 | 189 | 0.19 / 242.07 | 5 | 5 |
2 | 7 | 2011.04 | 40 | 14.75 | 3468 | 2046 | 2.23 / 244.12 | 5 | 19 |
3 | 13 | 1290.12 | 20 | 14.85 | 2377 | 706 | 2.94 / 244.82 | 4 | 28 |
4 | 13 | 592.16 | 20 | 15.03 | 1269 | 381 | 3.32 / 245.20 | 4 | 26 |
5 | 13 | 122.72 | 20 | 15.15 | 510 | 155 | 3.48 / 245.36 | 5 | 27 |
6 | 13 | 43.36 | 20 | 15.17 | 369 | 112 | 3.59 / 245.47 | 5 | 25 |
7 | 8 | 0.00 | 257 | 15.13 | 288 | 1120 | 4.71 / 246.59 | 5 | 153 |
Average= | 8.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.68 | 29 | 15.14 | 457 | 201 | 0.20 / 237.35 | 5 | 6 |
2 | 7 | 2011.32 | 40 | 14.75 | 3469 | 2047 | 2.25 / 239.40 | 6 | 20 |
3 | 13 | 1281.12 | 20 | 14.86 | 2358 | 701 | 2.95 / 240.10 | 4 | 28 |
4 | 13 | 596.28 | 20 | 15.03 | 1275 | 383 | 3.33 / 240.48 | 5 | 27 |
5 | 13 | 118.36 | 20 | 15.16 | 503 | 153 | 3.48 / 240.63 | 5 | 27 |
6 | 13 | 65.88 | 20 | 15.17 | 408 | 124 | 3.61 / 240.76 | 5 | 29 |
7 | 8 | 0.00 | 257 | 15.14 | 289 | 1124 | 4.73 / 241.88 | 5 | 159 |
Average= | 8.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.12 | 29 | 15.14 | 428 | 188 | 0.19 / 232.60 | 5 | 5 |
2 | 7 | 2005.96 | 40 | 14.76 | 3458 | 2042 | 2.23 / 234.64 | 5 | 19 |
3 | 13 | 1302.60 | 20 | 14.87 | 2393 | 712 | 2.94 / 235.36 | 4 | 26 |
4 | 13 | 606.60 | 20 | 15.04 | 1293 | 389 | 3.33 / 235.74 | 4 | 27 |
5 | 13 | 135.72 | 20 | 15.16 | 532 | 161 | 3.49 / 235.91 | 5 | 24 |
6 | 13 | 52.56 | 20 | 15.18 | 386 | 117 | 3.61 / 236.02 | 5 | 22 |
7 | 8 | 0.12 | 257 | 15.15 | 289 | 1125 | 4.73 / 237.15 | 5 | 148 |
Average= | 8.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.12 | 29 | 15.14 | 435 | 191 | 0.19 / 227.88 | 5 | 6 |
2 | 7 | 2005.84 | 40 | 14.76 | 3454 | 2039 | 2.23 / 229.92 | 6 | 17 |
3 | 13 | 1296.20 | 20 | 14.87 | 2386 | 710 | 2.94 / 230.63 | 4 | 27 |
4 | 13 | 586.28 | 20 | 15.05 | 1260 | 379 | 3.32 / 231.01 | 4 | 29 |
5 | 13 | 122.44 | 20 | 15.17 | 505 | 153 | 3.47 / 231.16 | 5 | 28 |
6 | 13 | 71.80 | 20 | 15.17 | 422 | 128 | 3.60 / 231.29 | 5 | 25 |
7 | 8 | 0.04 | 255 | 15.15 | 291 | 1124 | 4.72 / 232.41 | 5 | 138 |
Average= | 8.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.56 | 29 | 15.14 | 443 | 195 | 0.19 / 223.15 | 5 | 5 |
2 | 7 | 2011.72 | 41 | 14.76 | 3465 | 2097 | 2.29 / 225.24 | 5 | 18 |
3 | 13 | 1193.96 | 20 | 14.90 | 2208 | 658 | 2.95 / 225.90 | 4 | 28 |
4 | 13 | 620.12 | 20 | 15.04 | 1298 | 390 | 3.34 / 226.29 | 4 | 28 |
5 | 13 | 131.36 | 20 | 15.17 | 522 | 158 | 3.50 / 226.45 | 5 | 26 |
6 | 13 | 78.20 | 20 | 15.17 | 430 | 130 | 3.63 / 226.58 | 5 | 26 |
7 | 8 | 0.12 | 255 | 15.15 | 287 | 1109 | 4.74 / 227.69 | 5 | 132 |
Average= | 8.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.96 | 29 | 15.15 | 436 | 192 | 0.19 / 218.41 | 5 | 6 |
2 | 7 | 2007.52 | 40 | 14.76 | 3458 | 2042 | 2.23 / 220.45 | 6 | 20 |
3 | 13 | 1294.88 | 20 | 14.87 | 2393 | 712 | 2.94 / 221.17 | 4 | 29 |
4 | 13 | 593.60 | 20 | 15.05 | 1272 | 383 | 3.33 / 221.55 | 4 | 29 |
5 | 13 | 124.24 | 20 | 15.17 | 513 | 156 | 3.48 / 221.71 | 5 | 25 |
6 | 13 | 70.92 | 20 | 15.18 | 416 | 126 | 3.61 / 221.83 | 5 | 26 |
7 | 8 | 0.08 | 257 | 15.15 | 288 | 1121 | 4.73 / 222.95 | 5 | 156 |
Average= | 8.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.00 | 29 | 15.16 | 424 | 186 | 0.19 / 213.57 | 5 | 5 |
2 | 7 | 2007.16 | 40 | 14.77 | 3460 | 2044 | 2.23 / 215.62 | 5 | 19 |
3 | 13 | 1311.16 | 20 | 14.87 | 2419 | 719 | 2.95 / 216.34 | 4 | 27 |
4 | 13 | 717.40 | 20 | 15.01 | 1476 | 443 | 3.39 / 216.78 | 4 | 27 |
5 | 13 | 124.48 | 20 | 15.17 | 520 | 158 | 3.55 / 216.94 | 5 | 25 |
6 | 13 | 66.16 | 20 | 15.18 | 417 | 127 | 3.68 / 217.06 | 5 | 29 |
7 | 13 | 17.80 | 20 | 15.19 | 334 | 101 | 3.78 / 217.17 | 5 | 29 |
8 | 8 | 0.00 | 238 | 15.15 | 293 | 1056 | 4.84 / 218.22 | 5 | 151 |
Average= | 9.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.68 | 29 | 15.16 | 425 | 187 | 0.19 / 208.83 | 5 | 5 |
2 | 7 | 2011.52 | 40 | 14.77 | 3479 | 2055 | 2.24 / 210.88 | 5 | 18 |
3 | 13 | 1308.68 | 20 | 14.88 | 2420 | 720 | 2.96 / 211.60 | 4 | 26 |
4 | 13 | 606.24 | 20 | 15.06 | 1293 | 389 | 3.35 / 211.99 | 4 | 29 |
5 | 13 | 131.92 | 20 | 15.18 | 521 | 158 | 3.51 / 212.15 | 5 | 23 |
6 | 13 | 51.16 | 20 | 15.19 | 381 | 116 | 3.63 / 212.27 | 5 | 25 |
7 | 13 | 14.32 | 20 | 15.20 | 318 | 97 | 3.72 / 212.36 | 5 | 28 |
8 | 8 | -0.04 | 235 | 15.16 | 287 | 1022 | 4.74 / 213.39 | 5 | 143 |
Average= | 9.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.08 | 29 | 15.16 | 425 | 187 | 0.19 / 204.10 | 5 | 5 |
2 | 7 | 2010.64 | 40 | 14.78 | 3478 | 2056 | 2.24 / 206.15 | 5 | 18 |
3 | 13 | 1296.76 | 20 | 14.89 | 2392 | 712 | 2.96 / 206.86 | 4 | 26 |
4 | 13 | 607.20 | 20 | 15.06 | 1292 | 389 | 3.34 / 207.25 | 5 | 31 |
5 | 13 | 131.44 | 20 | 15.18 | 524 | 159 | 3.50 / 207.41 | 5 | 26 |
6 | 13 | 60.76 | 20 | 15.20 | 402 | 122 | 3.63 / 207.54 | 5 | 25 |
7 | 8 | 0.12 | 255 | 15.17 | 286 | 1106 | 4.73 / 208.64 | 5 | 137 |
Average= | 9.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.64 | 29 | 15.17 | 431 | 190 | 0.19 / 199.35 | 5 | 5 |
2 | 7 | 2010.48 | 40 | 14.77 | 3470 | 2050 | 2.24 / 201.40 | 5 | 24 |
3 | 13 | 1303.28 | 20 | 14.89 | 2399 | 714 | 2.95 / 202.11 | 4 | 26 |
4 | 13 | 604.88 | 20 | 15.06 | 1289 | 388 | 3.34 / 202.50 | 5 | 29 |
5 | 13 | 128.92 | 20 | 15.19 | 515 | 156 | 3.50 / 202.66 | 5 | 21 |
6 | 13 | 72.60 | 20 | 15.20 | 423 | 129 | 3.63 / 202.78 | 5 | 25 |
7 | 8 | 0.00 | 255 | 15.17 | 291 | 1126 | 4.75 / 203.91 | 5 | 151 |
Average= | 9.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.36 | 28 | 15.17 | 434 | 184 | 0.18 / 194.61 | 5 | 5 |
2 | 7 | 2013.08 | 40 | 14.79 | 3468 | 2052 | 2.24 / 196.66 | 5 | 15 |
3 | 13 | 1311.40 | 20 | 14.90 | 2409 | 718 | 2.95 / 197.38 | 4 | 23 |
4 | 13 | 597.40 | 20 | 15.07 | 1271 | 383 | 3.34 / 197.76 | 4 | 26 |
5 | 13 | 111.04 | 20 | 15.20 | 482 | 147 | 3.48 / 197.91 | 5 | 26 |
6 | 13 | 62.96 | 20 | 15.21 | 404 | 123 | 3.61 / 198.03 | 5 | 29 |
7 | 8 | -0.04 | 255 | 15.17 | 291 | 1126 | 4.73 / 199.16 | 5 | 147 |
Average= | 9.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.44 | 28 | 15.17 | 437 | 186 | 0.19 / 189.85 | 5 | 5 |
2 | 7 | 2007.60 | 40 | 14.79 | 3472 | 2054 | 2.24 / 191.91 | 5 | 23 |
3 | 13 | 1290.24 | 20 | 14.91 | 2366 | 706 | 2.95 / 192.61 | 4 | 26 |
4 | 13 | 606.16 | 20 | 15.08 | 1284 | 387 | 3.33 / 193.00 | 5 | 27 |
5 | 13 | 126.24 | 20 | 15.20 | 517 | 157 | 3.49 / 193.16 | 5 | 23 |
6 | 13 | 66.00 | 20 | 15.20 | 413 | 126 | 3.62 / 193.28 | 5 | 24 |
7 | 13 | 16.44 | 20 | 15.21 | 332 | 101 | 3.72 / 193.38 | 5 | 34 |
8 | 8 | -0.16 | 236 | 15.17 | 291 | 1042 | 4.76 / 194.42 | 5 | 150 |
Average= | 10.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.20 | 28 | 15.18 | 431 | 183 | 0.18 / 185.10 | 5 | 5 |
2 | 7 | 2010.40 | 40 | 14.80 | 3471 | 2055 | 2.24 / 187.15 | 5 | 19 |
3 | 13 | 1295.12 | 20 | 14.91 | 2392 | 713 | 2.95 / 187.86 | 4 | 27 |
4 | 13 | 614.72 | 20 | 15.07 | 1306 | 394 | 3.34 / 188.26 | 4 | 26 |
5 | 13 | 125.40 | 20 | 15.20 | 512 | 156 | 3.50 / 188.41 | 5 | 29 |
6 | 13 | 66.12 | 20 | 15.21 | 412 | 125 | 3.63 / 188.54 | 5 | 30 |
7 | 13 | 17.08 | 20 | 15.22 | 325 | 99 | 3.72 / 188.64 | 5 | 34 |
8 | 8 | -0.08 | 233 | 15.18 | 291 | 1029 | 4.75 / 189.67 | 5 | 149 |
Average= | 10.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.60 | 28 | 15.18 | 432 | 184 | 0.18 / 180.25 | 5 | 5 |
2 | 7 | 2011.76 | 40 | 14.80 | 3477 | 2058 | 2.24 / 182.31 | 5 | 20 |
3 | 13 | 1402.08 | 20 | 14.89 | 2561 | 763 | 3.00 / 183.07 | 4 | 25 |
4 | 13 | 663.72 | 20 | 15.07 | 1386 | 418 | 3.42 / 183.49 | 4 | 30 |
5 | 13 | 100.40 | 20 | 15.21 | 472 | 144 | 3.57 / 183.63 | 5 | 26 |
6 | 13 | 63.92 | 20 | 15.21 | 410 | 125 | 3.69 / 183.76 | 5 | 24 |
7 | 13 | 35.52 | 20 | 15.22 | 360 | 110 | 3.80 / 183.87 | 5 | 18 |
8 | 8 | 0.00 | 235 | 15.18 | 293 | 1045 | 4.85 / 184.91 | 5 | 137 |
Average= | 10.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.68 | 28 | 15.18 | 431 | 183 | 0.18 / 175.54 | 5 | 6 |
2 | 7 | 2002.72 | 40 | 14.81 | 3449 | 2043 | 2.23 / 177.59 | 6 | 22 |
3 | 13 | 1264.92 | 20 | 14.93 | 2336 | 698 | 2.92 / 178.28 | 4 | 27 |
4 | 13 | 580.68 | 20 | 15.09 | 1247 | 376 | 3.30 / 178.66 | 5 | 30 |
5 | 13 | 109.68 | 20 | 15.21 | 488 | 148 | 3.45 / 178.81 | 5 | 25 |
6 | 13 | 61.08 | 20 | 15.22 | 404 | 123 | 3.57 / 178.93 | 5 | 24 |
7 | 13 | 15.88 | 20 | 15.23 | 325 | 99 | 3.67 / 179.03 | 5 | 24 |
8 | 8 | -0.08 | 233 | 15.19 | 293 | 1037 | 4.71 / 180.07 | 5 | 137 |
Average= | 11.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.36 | 29 | 15.19 | 436 | 192 | 0.19 / 170.70 | 5 | 6 |
2 | 7 | 2006.08 | 40 | 14.81 | 3463 | 2051 | 2.24 / 172.75 | 6 | 18 |
3 | 13 | 1400.80 | 20 | 14.90 | 2551 | 760 | 3.00 / 173.51 | 4 | 25 |
4 | 13 | 653.84 | 20 | 15.08 | 1361 | 410 | 3.41 / 173.92 | 5 | 30 |
5 | 13 | 150.68 | 20 | 15.21 | 556 | 169 | 3.58 / 174.09 | 5 | 26 |
6 | 13 | 60.08 | 20 | 15.23 | 400 | 122 | 3.71 / 174.21 | 5 | 24 |
7 | 13 | 16.88 | 20 | 15.23 | 326 | 99 | 3.80 / 174.31 | 5 | 23 |
8 | 8 | 0.00 | 235 | 15.19 | 294 | 1049 | 4.85 / 175.36 | 5 | 135 |
Average= | 11.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.60 | 29 | 15.19 | 459 | 202 | 0.20 / 165.96 | 5 | 6 |
2 | 7 | 2002.56 | 40 | 14.81 | 3462 | 2051 | 2.25 / 168.01 | 6 | 17 |
3 | 13 | 1268.20 | 20 | 14.93 | 2345 | 700 | 2.95 / 168.71 | 4 | 25 |
4 | 13 | 581.92 | 20 | 15.11 | 1249 | 377 | 3.33 / 169.09 | 5 | 26 |
5 | 13 | 114.44 | 20 | 15.22 | 493 | 150 | 3.48 / 169.24 | 5 | 27 |
6 | 13 | 61.08 | 20 | 15.23 | 403 | 123 | 3.60 / 169.36 | 5 | 21 |
7 | 13 | 13.72 | 20 | 15.23 | 321 | 98 | 3.70 / 169.46 | 5 | 34 |
8 | 8 | -0.04 | 235 | 15.19 | 293 | 1046 | 4.75 / 170.50 | 5 | 149 |
Average= | 12.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.16 | 29 | 15.19 | 436 | 192 | 0.19 / 161.17 | 5 | 6 |
2 | 7 | 2003.16 | 41 | 14.81 | 3470 | 2107 | 2.30 / 163.28 | 6 | 23 |
3 | 13 | 1278.60 | 20 | 14.93 | 2361 | 705 | 3.00 / 163.98 | 4 | 28 |
4 | 13 | 570.56 | 20 | 15.11 | 1235 | 373 | 3.38 / 164.36 | 5 | 26 |
5 | 13 | 112.44 | 20 | 15.22 | 494 | 150 | 3.53 / 164.51 | 5 | 25 |
6 | 13 | 67.24 | 20 | 15.23 | 412 | 125 | 3.65 / 164.63 | 5 | 26 |
7 | 8 | 0.08 | 255 | 15.20 | 290 | 1124 | 4.78 / 165.76 | 5 | 147 |
Average= | 12.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.40 | 28 | 15.20 | 436 | 186 | 0.19 / 156.41 | 5 | 6 |
2 | 7 | 2008.72 | 40 | 14.81 | 3473 | 2057 | 2.24 / 158.47 | 6 | 22 |
3 | 13 | 1291.40 | 20 | 14.93 | 2384 | 712 | 2.95 / 159.18 | 4 | 28 |
4 | 13 | 598.52 | 20 | 15.11 | 1276 | 386 | 3.34 / 159.56 | 4 | 30 |
5 | 13 | 109.84 | 20 | 15.22 | 487 | 148 | 3.49 / 159.71 | 5 | 28 |
6 | 13 | 71.48 | 20 | 15.23 | 423 | 129 | 3.62 / 159.84 | 5 | 25 |
7 | 8 | 0.04 | 255 | 15.20 | 294 | 1140 | 4.76 / 160.98 | 5 | 137 |
Average= | 13.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.84 | 28 | 15.20 | 443 | 189 | 0.19 / 151.60 | 5 | 6 |
2 | 7 | 2009.72 | 40 | 14.82 | 3475 | 2060 | 2.25 / 153.66 | 6 | 19 |
3 | 13 | 1301.24 | 20 | 14.94 | 2395 | 716 | 2.96 / 154.38 | 4 | 27 |
4 | 13 | 701.56 | 20 | 15.08 | 1448 | 437 | 3.40 / 154.82 | 4 | 28 |
5 | 13 | 100.72 | 20 | 15.23 | 475 | 145 | 3.55 / 154.96 | 5 | 26 |
6 | 13 | 70.52 | 20 | 15.23 | 423 | 129 | 3.67 / 155.09 | 5 | 30 |
7 | 8 | 0.08 | 255 | 15.21 | 292 | 1133 | 4.81 / 156.22 | 5 | 153 |
Average= | 14.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.80 | 28 | 15.20 | 442 | 188 | 0.19 / 146.82 | 5 | 6 |
2 | 7 | 2012.80 | 40 | 14.81 | 3482 | 2063 | 2.25 / 148.88 | 6 | 19 |
3 | 13 | 1390.20 | 20 | 14.92 | 2545 | 759 | 3.01 / 149.64 | 4 | 24 |
4 | 13 | 548.76 | 20 | 15.13 | 1206 | 365 | 3.38 / 150.00 | 5 | 28 |
5 | 13 | 93.32 | 20 | 15.24 | 465 | 142 | 3.52 / 150.15 | 5 | 21 |
6 | 13 | 65.36 | 20 | 15.24 | 417 | 127 | 3.64 / 150.27 | 5 | 29 |
7 | 8 | 0.00 | 253 | 15.21 | 297 | 1143 | 4.79 / 151.42 | 5 | 129 |
Average= | 15.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.36 | 28 | 15.21 | 433 | 184 | 0.18 / 141.98 | 5 | 5 |
2 | 7 | 2007.52 | 40 | 14.82 | 3463 | 2053 | 2.24 / 144.03 | 5 | 19 |
3 | 13 | 1391.80 | 20 | 14.91 | 2541 | 758 | 2.99 / 144.79 | 4 | 29 |
4 | 13 | 658.32 | 20 | 15.10 | 1375 | 415 | 3.41 / 145.20 | 5 | 28 |
5 | 13 | 90.68 | 20 | 15.24 | 456 | 139 | 3.55 / 145.34 | 5 | 28 |
6 | 13 | 58.16 | 20 | 15.25 | 402 | 123 | 3.67 / 145.46 | 5 | 21 |
7 | 13 | 15.60 | 20 | 15.25 | 328 | 100 | 3.77 / 145.56 | 5 | 30 |
8 | 8 | -0.08 | 236 | 15.21 | 297 | 1066 | 4.84 / 146.63 | 5 | 168 |
Average= | 16.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.84 | 28 | 15.22 | 436 | 186 | 0.19 / 137.26 | 5 | 6 |
2 | 7 | 2005.48 | 40 | 14.83 | 3465 | 2055 | 2.24 / 139.32 | 6 | 19 |
3 | 13 | 1300.28 | 20 | 14.95 | 2397 | 717 | 2.96 / 140.04 | 4 | 28 |
4 | 13 | 586.16 | 20 | 15.12 | 1256 | 380 | 3.34 / 140.42 | 5 | 30 |
5 | 13 | 110.28 | 20 | 15.24 | 481 | 147 | 3.48 / 140.56 | 5 | 24 |
6 | 13 | 43.72 | 20 | 15.25 | 373 | 114 | 3.60 / 140.68 | 5 | 28 |
7 | 8 | 0.04 | 250 | 15.22 | 293 | 1115 | 4.71 / 141.79 | 5 | 136 |
Average= | 17.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.80 | 28 | 15.22 | 432 | 184 | 0.18 / 132.55 | 5 | 5 |
2 | 7 | 2015.08 | 40 | 14.82 | 3484 | 2065 | 2.25 / 134.61 | 5 | 24 |
3 | 13 | 1304.60 | 20 | 14.95 | 2399 | 717 | 2.97 / 135.33 | 4 | 25 |
4 | 13 | 584.08 | 20 | 15.12 | 1252 | 379 | 3.35 / 135.71 | 5 | 29 |
5 | 13 | 112.92 | 20 | 15.24 | 492 | 150 | 3.50 / 135.86 | 5 | 26 |
6 | 13 | 46.44 | 20 | 15.25 | 375 | 114 | 3.61 / 135.97 | 5 | 25 |
7 | 8 | 0.04 | 253 | 15.22 | 287 | 1105 | 4.71 / 137.08 | 5 | 132 |
Average= | 19.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.72 | 28 | 15.22 | 455 | 194 | 0.19 / 127.84 | 5 | 5 |
2 | 7 | 2008.48 | 40 | 14.83 | 3468 | 2057 | 2.25 / 129.90 | 5 | 19 |
3 | 13 | 1278.88 | 20 | 14.96 | 2364 | 707 | 2.96 / 130.61 | 4 | 26 |
4 | 13 | 585.16 | 20 | 15.13 | 1260 | 381 | 3.34 / 130.99 | 5 | 28 |
5 | 13 | 104.96 | 20 | 15.25 | 478 | 146 | 3.49 / 131.13 | 5 | 24 |
6 | 13 | 39.92 | 20 | 15.26 | 365 | 111 | 3.60 / 131.25 | 5 | 24 |
7 | 8 | 0.08 | 253 | 15.23 | 290 | 1117 | 4.71 / 132.36 | 5 | 140 |
Average= | 22.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.92 | 28 | 15.22 | 442 | 188 | 0.19 / 123.07 | 5 | 5 |
2 | 7 | 2006.32 | 41 | 14.83 | 3482 | 2117 | 2.31 / 125.19 | 5 | 21 |
3 | 13 | 1277.88 | 20 | 14.96 | 2363 | 707 | 3.01 / 125.89 | 4 | 28 |
4 | 13 | 569.04 | 20 | 15.14 | 1232 | 373 | 3.39 / 126.27 | 5 | 29 |
5 | 13 | 103.00 | 20 | 15.25 | 473 | 144 | 3.53 / 126.41 | 5 | 25 |
6 | 13 | 40.68 | 20 | 15.26 | 371 | 113 | 3.64 / 126.53 | 5 | 24 |
7 | 13 | 12.48 | 20 | 15.27 | 322 | 98 | 3.74 / 126.62 | 5 | 25 |
8 | 8 | 0.04 | 233 | 15.23 | 289 | 1026 | 4.77 / 127.65 | 5 | 130 |
Average= | 25.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.44 | 28 | 15.22 | 435 | 185 | 0.19 / 118.28 | 5 | 5 |
2 | 7 | 2008.56 | 41 | 14.83 | 3476 | 2114 | 2.30 / 120.39 | 5 | 21 |
3 | 13 | 1278.60 | 20 | 14.97 | 2365 | 708 | 3.01 / 121.10 | 4 | 27 |
4 | 13 | 572.44 | 20 | 15.14 | 1240 | 375 | 3.38 / 121.48 | 5 | 28 |
5 | 13 | 99.20 | 20 | 15.26 | 469 | 143 | 3.53 / 121.62 | 5 | 27 |
6 | 13 | 57.04 | 20 | 15.26 | 396 | 121 | 3.65 / 121.74 | 5 | 25 |
7 | 8 | 0.00 | 255 | 15.23 | 294 | 1142 | 4.79 / 122.88 | 5 | 142 |
Average= | 30.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.12 | 28 | 15.23 | 440 | 188 | 0.19 / 113.53 | 5 | 5 |
2 | 7 | 2004.36 | 40 | 14.84 | 3460 | 2054 | 2.24 / 115.58 | 5 | 24 |
3 | 13 | 1378.60 | 20 | 14.95 | 2515 | 752 | 2.99 / 116.33 | 4 | 26 |
4 | 13 | 556.20 | 20 | 15.15 | 1211 | 367 | 3.36 / 116.70 | 5 | 27 |
5 | 13 | 96.72 | 20 | 15.26 | 465 | 142 | 3.50 / 116.84 | 5 | 26 |
6 | 13 | 55.84 | 20 | 15.26 | 399 | 122 | 3.62 / 116.97 | 5 | 30 |
7 | 8 | 0.04 | 253 | 15.23 | 293 | 1129 | 4.75 / 118.09 | 5 | 131 |
Average= | 39.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.84 | 28 | 15.23 | 434 | 185 | 0.19 / 108.77 | 5 | 5 |
2 | 7 | 2003.12 | 40 | 14.85 | 3474 | 2064 | 2.25 / 110.83 | 5 | 22 |
3 | 13 | 1398.44 | 20 | 14.95 | 2542 | 760 | 3.01 / 111.59 | 4 | 27 |
4 | 13 | 550.40 | 20 | 15.16 | 1205 | 365 | 3.37 / 111.95 | 5 | 28 |
5 | 13 | 111.20 | 20 | 15.26 | 484 | 148 | 3.52 / 112.10 | 5 | 26 |
6 | 13 | 65.00 | 20 | 15.27 | 404 | 123 | 3.65 / 112.23 | 5 | 25 |
7 | 8 | 0.16 | 255 | 15.24 | 287 | 1115 | 4.76 / 113.34 | 5 | 135 |
Average= | 56.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.28 | 28 | 15.23 | 443 | 189 | 0.19 / 104.02 | 5 | 5 |
2 | 7 | 2003.12 | 40 | 14.84 | 3472 | 2061 | 2.25 / 106.08 | 5 | 22 |
3 | 13 | 1391.04 | 20 | 14.95 | 2546 | 761 | 3.01 / 106.84 | 4 | 28 |
4 | 13 | 461.84 | 20 | 15.18 | 1065 | 323 | 3.33 / 107.17 | 5 | 27 |
5 | 13 | 118.48 | 20 | 15.26 | 502 | 153 | 3.49 / 107.32 | 5 | 25 |
6 | 13 | 69.84 | 20 | 15.27 | 417 | 127 | 3.62 / 107.45 | 5 | 24 |
7 | 8 | 0.04 | 255 | 15.24 | 292 | 1135 | 4.75 / 108.58 | 5 | 143 |
Average= | 108.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.12 | 28 | 15.24 | 438 | 187 | 0.19 / 99.24 | 5 | 5 |
2 | 7 | 2006.60 | 41 | 14.85 | 3480 | 2119 | 2.31 / 101.36 | 5 | 19 |
3 | 13 | 1294.64 | 20 | 14.98 | 2398 | 718 | 3.02 / 102.08 | 4 | 28 |
4 | 13 | 473.32 | 20 | 15.18 | 1078 | 327 | 3.35 / 102.41 | 5 | 29 |
5 | 13 | 129.00 | 20 | 15.26 | 519 | 158 | 3.51 / 102.57 | 5 | 28 |
6 | 13 | 74.12 | 20 | 15.27 | 426 | 130 | 3.64 / 102.70 | 5 | 23 |
7 | 8 | 0.04 | 253 | 15.25 | 294 | 1134 | 4.77 / 103.83 | 5 | 131 |
Average= | 5.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.08 | 28 | 15.24 | 437 | 186 | 0.19 / 94.55 | 5 | 6 |
2 | 7 | 2006.36 | 40 | 14.86 | 3482 | 2070 | 2.26 / 96.62 | 17 | 21 |
3 | 13 | 1213.88 | 20 | 15.00 | 2273 | 682 | 2.94 / 97.30 | 4 | 27 |
4 | 13 | 535.92 | 20 | 15.17 | 1183 | 359 | 3.30 / 97.66 | 5 | 28 |
5 | 13 | 116.32 | 20 | 15.27 | 500 | 153 | 3.45 / 97.81 | 5 | 23 |
6 | 13 | 70.68 | 20 | 15.28 | 418 | 128 | 3.58 / 97.94 | 5 | 25 |
7 | 8 | 0.16 | 255 | 15.25 | 288 | 1120 | 4.70 / 99.06 | 5 | 159 |
Average= | 5.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.32 | 28 | 15.25 | 461 | 197 | 0.20 / 89.72 | 5 | 5 |
2 | 7 | 2007.68 | 40 | 14.86 | 3480 | 2069 | 2.27 / 91.79 | 5 | 20 |
3 | 13 | 1410.04 | 20 | 14.96 | 2573 | 770 | 3.04 / 92.56 | 4 | 28 |
4 | 13 | 579.80 | 20 | 15.16 | 1252 | 380 | 3.41 / 92.93 | 5 | 27 |
5 | 13 | 110.40 | 20 | 15.27 | 491 | 150 | 3.56 / 93.08 | 5 | 27 |
6 | 13 | 61.00 | 20 | 15.28 | 408 | 125 | 3.69 / 93.21 | 5 | 21 |
7 | 8 | 0.00 | 253 | 15.25 | 298 | 1150 | 4.84 / 94.36 | 5 | 132 |
Average= | 5.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.16 | 28 | 15.25 | 432 | 184 | 0.18 / 84.93 | 5 | 5 |
2 | 7 | 2005.20 | 40 | 14.86 | 3481 | 2069 | 2.25 / 87.00 | 5 | 20 |
3 | 13 | 1304.16 | 20 | 14.99 | 2412 | 723 | 2.98 / 87.72 | 4 | 26 |
4 | 13 | 575.60 | 20 | 15.16 | 1248 | 378 | 3.36 / 88.10 | 5 | 28 |
5 | 13 | 106.28 | 20 | 15.28 | 483 | 148 | 3.50 / 88.25 | 5 | 26 |
6 | 13 | 60.40 | 20 | 15.29 | 407 | 124 | 3.63 / 88.37 | 5 | 24 |
7 | 8 | 0.08 | 255 | 15.25 | 295 | 1147 | 4.77 / 89.52 | 5 | 150 |
Average= | 5.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.68 | 28 | 15.25 | 439 | 187 | 0.19 / 80.09 | 5 | 5 |
2 | 7 | 2003.68 | 40 | 14.87 | 3466 | 2062 | 2.25 / 82.15 | 5 | 20 |
3 | 13 | 1381.52 | 20 | 14.98 | 2524 | 756 | 3.01 / 82.91 | 4 | 26 |
4 | 13 | 646.44 | 20 | 15.15 | 1361 | 412 | 3.42 / 83.32 | 4 | 29 |
5 | 13 | 96.88 | 20 | 15.28 | 469 | 143 | 3.56 / 83.47 | 5 | 25 |
6 | 13 | 57.36 | 20 | 15.29 | 403 | 123 | 3.68 / 83.59 | 5 | 26 |
7 | 8 | 0.08 | 255 | 15.26 | 297 | 1156 | 4.84 / 84.75 | 5 | 137 |
Average= | 5.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.32 | 28 | 15.25 | 434 | 185 | 0.19 / 75.31 | 5 | 5 |
2 | 7 | 2006.96 | 40 | 14.86 | 3477 | 2067 | 2.25 / 77.38 | 5 | 17 |
3 | 13 | 1221.28 | 20 | 15.01 | 2282 | 685 | 2.94 / 78.07 | 4 | 28 |
4 | 13 | 621.92 | 20 | 15.15 | 1323 | 401 | 3.34 / 78.47 | 4 | 28 |
5 | 13 | 123.72 | 20 | 15.27 | 518 | 158 | 3.50 / 78.62 | 5 | 25 |
6 | 13 | 39.12 | 20 | 15.29 | 372 | 114 | 3.61 / 78.74 | 5 | 28 |
7 | 8 | 0.08 | 255 | 15.26 | 300 | 1167 | 4.78 / 79.91 | 5 | 142 |
Average= | 5.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.20 | 28 | 15.25 | 443 | 189 | 0.19 / 70.55 | 5 | 5 |
2 | 7 | 2009.04 | 40 | 14.87 | 3473 | 2066 | 2.25 / 72.61 | 5 | 21 |
3 | 13 | 1302.56 | 20 | 14.99 | 2404 | 721 | 2.98 / 73.33 | 4 | 28 |
4 | 13 | 573.72 | 20 | 15.17 | 1244 | 377 | 3.35 / 73.71 | 5 | 28 |
5 | 13 | 103.16 | 20 | 15.29 | 480 | 147 | 3.50 / 73.86 | 5 | 26 |
6 | 13 | 32.12 | 20 | 15.30 | 363 | 111 | 3.61 / 73.97 | 5 | 23 |
7 | 8 | 0.00 | 255 | 15.26 | 298 | 1160 | 4.77 / 75.13 | 5 | 153 |
Average= | 5.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.44 | 28 | 15.26 | 438 | 187 | 0.19 / 65.74 | 5 | 5 |
2 | 7 | 2005.76 | 40 | 14.87 | 3471 | 2065 | 2.25 / 67.80 | 5 | 20 |
3 | 13 | 1297.32 | 20 | 15.00 | 2400 | 720 | 2.97 / 68.52 | 4 | 29 |
4 | 13 | 598.08 | 20 | 15.16 | 1286 | 390 | 3.36 / 68.91 | 4 | 28 |
5 | 13 | 109.16 | 20 | 15.28 | 490 | 150 | 3.51 / 69.06 | 5 | 26 |
6 | 13 | 62.76 | 20 | 15.29 | 414 | 127 | 3.64 / 69.19 | 5 | 25 |
7 | 8 | 0.04 | 255 | 15.26 | 300 | 1167 | 4.81 / 70.36 | 5 | 144 |
Average= | 5.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.96 | 27 | 15.26 | 441 | 182 | 0.18 / 61.01 | 5 | 5 |
2 | 7 | 2005.32 | 40 | 14.88 | 3467 | 2064 | 2.25 / 63.07 | 15 | 20 |
3 | 13 | 1201.56 | 20 | 15.02 | 2250 | 676 | 2.92 / 63.75 | 4 | 29 |
4 | 13 | 528.72 | 20 | 15.19 | 1173 | 356 | 3.28 / 64.10 | 5 | 27 |
5 | 13 | 162.76 | 20 | 15.27 | 579 | 177 | 3.45 / 64.28 | 5 | 27 |
6 | 13 | 65.04 | 20 | 15.29 | 411 | 126 | 3.58 / 64.40 | 5 | 23 |
7 | 8 | 0.16 | 255 | 15.26 | 295 | 1148 | 4.73 / 65.55 | 5 | 146 |
Average= | 5.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.20 | 25 | 15.26 | 440 | 168 | 0.17 / 56.14 | 5 | 5 |
2 | 10 | 1036.68 | 3 | 15.23 | 1953 | 89 | 0.26 / 56.23 | 5 | 9 |
3 | 7 | 2009.96 | 40 | 14.88 | 3481 | 2072 | 2.33 / 58.31 | 15 | 19 |
4 | 13 | 1189.64 | 20 | 15.03 | 2232 | 671 | 3.00 / 58.98 | 4 | 30 |
5 | 13 | 608.20 | 20 | 15.17 | 1300 | 394 | 3.39 / 59.37 | 5 | 30 |
6 | 13 | 122.60 | 20 | 15.29 | 513 | 157 | 3.55 / 59.53 | 5 | 30 |
7 | 13 | 69.48 | 20 | 15.29 | 424 | 130 | 3.68 / 59.66 | 5 | 27 |
8 | 8 | 0.04 | 255 | 15.26 | 300 | 1167 | 4.85 / 60.82 | 5 | 150 |
Average= | 6.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.24 | 39 | 15.26 | 439 | 261 | 0.26 / 51.44 | 5 | 7 |
2 | 3 | 614.40 | -6 | 15.56 | 0 | 0 | 0.00 / 51.44 | 5 | 7 |
3 | 7 | 2002.72 | 40 | 14.89 | 3463 | 2063 | 2.32 / 53.50 | 7 | 19 |
4 | 13 | 1375.28 | 20 | 14.99 | 2521 | 756 | 3.08 / 54.25 | 4 | 29 |
5 | 13 | 440.28 | 20 | 15.22 | 1029 | 313 | 3.39 / 54.57 | 5 | 28 |
6 | 13 | 113.44 | 20 | 15.30 | 490 | 150 | 3.54 / 54.72 | 5 | 26 |
7 | 13 | 60.44 | 20 | 15.30 | 400 | 122 | 3.67 / 54.84 | 5 | 28 |
8 | 8 | 0.00 | 253 | 15.27 | 294 | 1136 | 4.80 / 55.98 | 5 | 132 |
Average= | 6.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.96 | 59 | 15.24 | 432 | 388 | 0.39 / 38.22 | 5 | 9 |
2 | 3 | 316.96 | -11 | 15.58 | 0 | 0 | 0.00 / 38.22 | 5 | 9 |
3 | 5 | 1831.16 | 20 | 14.94 | 3247 | 970 | 1.36 / 39.19 | 4 | 16 |
4 | 5 | 1799.64 | 20 | 14.90 | 3182 | 948 | 2.31 / 40.14 | 4 | 19 |
5 | 5 | 1418.44 | 10 | 15.06 | 2594 | 391 | 2.70 / 40.53 | 4 | 25 |
6 | 5 | 1300.84 | 7 | 15.14 | 2412 | 256 | 2.95 / 40.78 | 4 | 22 |
7 | 5 | 1301.96 | 7 | 15.15 | 2424 | 257 | 3.21 / 41.04 | 4 | 21 |
8 | 5 | 1336.76 | 8 | 15.15 | 2451 | 297 | 3.51 / 41.34 | 4 | 21 |
9 | 5 | 1366.04 | 9 | 15.15 | 2488 | 339 | 3.85 / 41.68 | 4 | 22 |
10 | 5 | 1306.72 | 8 | 15.19 | 2392 | 291 | 4.14 / 41.97 | 4 | 19 |
11 | 5 | 1381.00 | 9 | 15.17 | 2555 | 349 | 4.49 / 42.32 | 4 | 21 |
12 | 5 | 1326.08 | 8 | 15.18 | 2447 | 297 | 4.78 / 42.61 | 4 | 21 |
13 | 5 | 1434.64 | 11 | 15.13 | 2637 | 439 | 5.22 / 43.05 | 4 | 20 |
14 | 5 | 1469.56 | 12 | 15.10 | 2667 | 483 | 5.71 / 43.54 | 4 | 19 |
15 | 5 | 1411.88 | 10 | 15.13 | 2572 | 389 | 6.09 / 43.92 | 4 | 21 |
16 | 5 | 1424.84 | 10 | 15.14 | 2580 | 391 | 6.49 / 44.32 | 4 | 21 |
17 | 5 | 1378.80 | 9 | 15.15 | 2525 | 344 | 6.83 / 44.66 | 4 | 18 |
18 | 5 | 1394.48 | 10 | 15.15 | 2551 | 386 | 7.22 / 45.05 | 4 | 21 |
19 | 5 | 1333.40 | 8 | 15.17 | 2454 | 298 | 7.51 / 45.34 | 4 | 19 |
20 | 5 | 1315.72 | 8 | 15.19 | 2399 | 292 | 7.81 / 45.64 | 4 | 20 |
21 | 5 | 1339.24 | 8 | 15.18 | 2492 | 303 | 8.11 / 45.94 | 4 | 20 |
22 | 5 | 1323.32 | 8 | 15.19 | 2451 | 298 | 8.41 / 46.24 | 4 | 17 |
23 | 5 | 1381.24 | 9 | 15.16 | 2551 | 348 | 8.75 / 46.58 | 4 | 21 |
24 | 7 | 2004.32 | 40 | 14.89 | 3471 | 2067 | 10.82 / 48.65 | 21 | 21 |
25 | 13 | 1380.36 | 20 | 15.00 | 2525 | 757 | 11.58 / 49.41 | 4 | 27 |
26 | 13 | 557.88 | 20 | 15.19 | 1213 | 369 | 11.95 / 49.78 | 5 | 29 |
27 | 13 | 111.48 | 20 | 15.30 | 489 | 150 | 12.10 / 49.93 | 5 | 28 |
28 | 13 | 47.36 | 20 | 15.31 | 380 | 116 | 12.21 / 50.04 | 5 | 20 |
29 | 8 | 0.00 | 253 | 15.27 | 293 | 1132 | 13.35 / 51.18 | 5 | 129 |
Average= | 6.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.44 | 49 | 15.25 | 455 | 340 | 0.34 / 30.19 | 5 | 6 |
2 | 5 | 1478.48 | 12 | 15.10 | 2651 | 480 | 0.82 / 30.67 | 4 | 16 |
3 | 5 | 1690.72 | 17 | 14.96 | 2989 | 760 | 1.58 / 31.43 | 4 | 18 |
4 | 5 | 1558.96 | 14 | 15.01 | 2793 | 587 | 2.17 / 32.02 | 4 | 21 |
5 | 5 | 1324.24 | 8 | 15.12 | 2443 | 296 | 2.46 / 32.32 | 4 | 22 |
6 | 5 | 1309.96 | 8 | 15.15 | 2431 | 295 | 2.76 / 32.61 | 4 | 22 |
7 | 5 | 1485.80 | 12 | 15.08 | 2712 | 491 | 3.25 / 33.10 | 4 | 20 |
8 | 7 | 2009.48 | 40 | 14.89 | 3473 | 2069 | 5.32 / 35.17 | 20 | 21 |
9 | 13 | 1406.12 | 20 | 14.99 | 2557 | 767 | 6.08 / 35.94 | 4 | 29 |
10 | 13 | 696.88 | 20 | 15.15 | 1438 | 436 | 6.52 / 36.37 | 5 | 30 |
11 | 13 | 141.16 | 20 | 15.29 | 536 | 164 | 6.68 / 36.54 | 5 | 27 |
12 | 13 | 52.00 | 20 | 15.31 | 385 | 118 | 6.80 / 36.65 | 5 | 29 |
13 | 13 | 30.08 | 20 | 15.30 | 349 | 107 | 6.91 / 36.76 | 5 | 26 |
14 | 8 | 0.00 | 240 | 15.27 | 292 | 1070 | 7.98 / 37.83 | 5 | 134 |
Average= | 5.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.68 | 31 | 15.25 | 466 | 220 | 0.22 / 21.93 | 5 | 5 |
2 | 10 | 1006.84 | 4 | 15.22 | 1909 | 116 | 0.34 / 22.04 | 5 | 10 |
3 | 10 | 1039.20 | 3 | 15.22 | 1973 | 90 | 0.43 / 22.13 | 5 | 12 |
4 | 10 | 1245.32 | 3 | 15.20 | 2299 | 105 | 0.53 / 22.24 | 5 | 16 |
5 | 3 | 1226.40 | 6 | 15.17 | 2277 | 207 | 0.74 / 22.45 | 5 | 17 |
6 | 5 | 1516.32 | 13 | 15.05 | 2736 | 535 | 1.27 / 22.98 | 4 | 20 |
7 | 5 | 1438.12 | 11 | 15.08 | 2634 | 437 | 1.71 / 23.42 | 4 | 21 |
8 | 5 | 1377.04 | 9 | 15.12 | 2536 | 345 | 2.06 / 23.76 | 4 | 20 |
9 | 5 | 1341.92 | 8 | 15.16 | 2475 | 300 | 2.36 / 24.06 | 4 | 21 |
10 | 5 | 1325.40 | 8 | 15.17 | 2442 | 296 | 2.65 / 24.36 | 4 | 20 |
11 | 5 | 1383.52 | 9 | 15.15 | 2520 | 344 | 3.00 / 24.70 | 4 | 19 |
12 | 5 | 1395.24 | 10 | 15.14 | 2545 | 385 | 3.38 / 25.09 | 4 | 21 |
13 | 7 | 2006.96 | 40 | 14.89 | 3472 | 2068 | 5.45 / 27.16 | 21 | 22 |
14 | 13 | 1424.36 | 20 | 14.99 | 2596 | 778 | 6.23 / 27.94 | 4 | 28 |
15 | 13 | 741.76 | 20 | 15.14 | 1510 | 457 | 6.68 / 28.39 | 4 | 30 |
16 | 13 | 175.08 | 20 | 15.28 | 591 | 181 | 6.87 / 28.57 | 5 | 28 |
17 | 13 | 45.68 | 20 | 15.30 | 377 | 115 | 6.98 / 28.69 | 5 | 27 |
18 | 8 | -0.04 | 261 | 15.27 | 292 | 1164 | 8.14 / 29.85 | 5 | 154 |
Average= | 4.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.88 | 38 | 15.24 | 431 | 250 | 0.25 / 15.45 | 5 | 5 |
2 | 10 | 1006.32 | 4 | 15.25 | 1900 | 116 | 0.37 / 15.56 | 5 | 12 |
3 | 10 | 1081.28 | 3 | 15.24 | 2039 | 93 | 0.46 / 15.66 | 5 | 15 |
4 | 3 | 1029.20 | 1 | 15.28 | 1955 | 30 | 0.49 / 15.69 | 5 | 14 |
5 | 5 | 1373.60 | 9 | 15.15 | 2506 | 342 | 0.83 / 16.03 | 4 | 18 |
6 | 5 | 1425.40 | 10 | 15.13 | 2599 | 393 | 1.22 / 16.42 | 4 | 20 |
7 | 5 | 1358.96 | 9 | 15.16 | 2487 | 339 | 1.56 / 16.76 | 4 | 21 |
8 | 5 | 1346.68 | 9 | 15.15 | 2481 | 338 | 1.90 / 17.10 | 4 | 21 |
9 | 5 | 1470.16 | 12 | 15.11 | 2671 | 484 | 2.39 / 17.58 | 4 | 20 |
10 | 7 | 1507.44 | 40 | 15.02 | 2712 | 1629 | 4.01 / 19.21 | 20 | 23 |
11 | 13 | 1308.28 | 20 | 15.03 | 2409 | 724 | 4.74 / 19.94 | 4 | 24 |
12 | 13 | 569.40 | 20 | 15.19 | 1236 | 375 | 5.11 / 20.31 | 5 | 27 |
13 | 13 | 99.80 | 20 | 15.29 | 461 | 141 | 5.26 / 20.45 | 5 | 25 |
14 | 13 | 28.68 | 20 | 15.30 | 349 | 107 | 5.36 / 20.56 | 5 | 25 |
15 | 8 | -0.16 | 255 | 15.26 | 295 | 1148 | 6.51 / 21.71 | 5 | 148 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.68 | 28 | 15.26 | 454 | 194 | 0.19 / 8.67 | 5 | 5 |
2 | 10 | 1035.88 | 4 | 15.23 | 1952 | 119 | 0.31 / 8.79 | 5 | 12 |
3 | 10 | 1075.88 | 3 | 15.23 | 2023 | 92 | 0.41 / 8.88 | 5 | 14 |
4 | 3 | 1143.24 | 4 | 15.22 | 2133 | 130 | 0.54 / 9.01 | 5 | 18 |
5 | 5 | 1373.16 | 9 | 15.14 | 2500 | 341 | 0.88 / 9.35 | 4 | 20 |
6 | 5 | 1300.36 | 7 | 15.18 | 2415 | 257 | 1.13 / 9.61 | 4 | 21 |
7 | 5 | 1338.04 | 8 | 15.17 | 2461 | 299 | 1.43 / 9.91 | 4 | 20 |
8 | 5 | 1397.68 | 10 | 15.13 | 2523 | 382 | 1.81 / 10.29 | 4 | 20 |
9 | 5 | 1385.80 | 9 | 15.13 | 2519 | 343 | 2.16 / 10.63 | 4 | 20 |
10 | 5 | 1382.40 | 9 | 15.13 | 2505 | 341 | 2.50 / 10.97 | 4 | 20 |
11 | 7 | 1508.76 | 40 | 15.03 | 2708 | 1628 | 4.13 / 12.60 | 20 | 22 |
12 | 13 | 1185.52 | 20 | 15.06 | 2219 | 668 | 4.79 / 13.27 | 4 | 26 |
13 | 13 | 728.08 | 20 | 15.14 | 1491 | 451 | 5.24 / 13.72 | 4 | 27 |
14 | 13 | 146.40 | 20 | 15.28 | 553 | 169 | 5.41 / 13.89 | 5 | 26 |
15 | 13 | 44.12 | 20 | 15.30 | 378 | 116 | 5.53 / 14.01 | 5 | 25 |
16 | 13 | 11.56 | 20 | 15.30 | 322 | 99 | 5.63 / 14.10 | 5 | 25 |
17 | 8 | 0.04 | 242 | 15.26 | 296 | 1093 | 6.72 / 15.20 | 5 | 156 |
Average= | 3.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.68 | 31 | 15.29 | 459 | 218 | 0.22 / 4.55 | 5 | 5 |
2 | 3 | 856.80 | -2 | 15.57 | 0 | 0 | 0.00 / 4.55 | 5 | 5 |
3 | 7 | 1523.12 | 40 | 15.09 | 2713 | 1638 | 1.86 / 6.19 | 5 | 19 |
4 | 13 | 1204.88 | 20 | 15.11 | 2232 | 675 | 2.53 / 6.86 | 4 | 24 |
5 | 13 | 372.92 | 20 | 15.26 | 912 | 278 | 2.81 / 7.14 | 5 | 26 |
6 | 13 | 78.56 | 20 | 15.32 | 429 | 131 | 2.94 / 7.27 | 5 | 26 |
7 | 13 | 27.08 | 20 | 15.32 | 343 | 105 | 3.04 / 7.38 | 5 | 27 |
8 | 8 | 0.00 | 250 | 15.28 | 288 | 1100 | 4.14 / 8.48 | 5 | 136 |
Average= | 2.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.36 | 31 | 15.46 | 441 | 211 | 0.21 / 1.92 | 5 | 6 |
2 | 3 | 798.12 | -3 | 15.58 | 0 | 0 | 0.00 / 1.92 | 5 | 6 |
3 | 7 | 877.08 | 40 | 15.26 | 1702 | 1039 | 1.25 / 2.96 | 6 | 22 |
4 | 13 | 104.44 | 20 | 15.38 | 474 | 146 | 1.40 / 3.10 | 5 | 21 |
5 | 13 | 31.88 | 20 | 15.38 | 350 | 108 | 1.50 / 3.21 | 5 | 31 |
6 | 8 | -0.08 | 255 | 15.34 | 287 | 1123 | 2.63 / 4.33 | 5 | 148 |
Average= | 2.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 129.40 | 30 | 15.61 | 467 | 219 | 0.22 / 0.22 | 5 | 7 |
2 | 7 | 143.08 | 40 | 15.59 | 481 | 300 | 0.52 / 0.52 | 7 | 7 |
3 | 13 | 80.40 | 20 | 15.58 | 378 | 118 | 0.64 / 0.64 | 5 | 8 |
4 | 13 | 23.32 | 20 | 15.57 | 291 | 91 | 0.73 / 0.73 | 5 | 9 |
5 | 8 | 0.04 | 250 | 15.53 | 252 | 978 | 1.71 / 1.71 | 5 | -99 |
Average= | 1.71 (KJ/cycle) |