SIO Argo Site:
Pump Diagnostics Page   



Serial= 7695 WMO= 1902441

Return

←PreviousNext→

Cycle 108 GMT 21/11/2024 6:38:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.76 38 14.96 506 288 0.29 / 623.95 5 7
2 7 2005.00 40 14.65 3374 1977 2.26 / 625.93 7 21
3 13 1561.80 20 14.68 2769 813 3.08 / 626.74 4 25
4 13 970.52 20 14.76 1921 567 3.64 / 627.31 4 31
5 13 298.56 20 14.96 853 255 3.90 / 627.56 4 34
6 8 0.00 347 14.97 378 1964 5.86 / 629.53 5 168
Average= 7.07
(KJ/cycle)

Cycle 107 GMT 11/11/2024 10:39:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.40 38 14.95 528 300 0.30 / 618.06 5 7
2 7 2012.24 40 14.65 3400 1992 2.29 / 620.05 7 21
3 13 1555.16 20 14.68 2775 815 3.11 / 620.87 4 25
4 13 989.72 20 14.76 1933 571 3.68 / 621.44 4 32
5 13 330.80 20 14.95 907 271 3.95 / 621.71 4 31
6 8 0.00 349 14.97 374 1954 5.90 / 623.66 5 138
Average= 7.09
(KJ/cycle)

Cycle 106 GMT 1/11/2024 14:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.96 38 14.96 504 287 0.29 / 612.16 5 7
2 7 2014.36 40 14.65 3378 1980 2.27 / 614.14 7 18
3 13 1471.40 20 14.69 2635 774 3.04 / 614.91 4 26
4 13 1013.96 20 14.75 1963 579 3.62 / 615.49 4 30
5 13 412.36 20 14.92 1050 313 3.93 / 615.81 4 38
6 8 -0.04 347 14.97 376 1953 5.89 / 617.76 5 151
Average= 7.10
(KJ/cycle)

Cycle 105 GMT 22/10/2024 18:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.68 38 14.97 478 272 0.27 / 606.09 5 12
2 7 2018.56 40 14.66 3374 1979 2.25 / 608.07 12 20
3 13 1707.08 20 14.65 2973 871 3.12 / 608.94 4 23
4 13 1110.60 20 14.73 2108 621 3.74 / 609.56 4 31
5 13 507.44 20 14.88 1221 363 4.11 / 609.93 4 38
6 8 0.00 351 14.98 370 1945 6.05 / 611.87 5 153
Average= 7.11
(KJ/cycle)

Cycle 104 GMT 12/10/2024 22:48:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.72 38 14.96 522 297 0.30 / 600.32 5 9
2 7 2016.16 40 14.64 3393 1987 2.28 / 602.31 9 19
3 13 1483.20 20 14.69 2657 781 3.06 / 603.09 4 25
4 13 1059.12 20 14.74 2043 602 3.67 / 603.69 4 31
5 13 474.48 20 14.89 1143 340 4.01 / 604.03 4 38
6 8 0.08 351 14.98 341 1793 5.80 / 605.82 5 143
Average= 7.13
(KJ/cycle)

Cycle 103 GMT 3/10/2024 2:38: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.44 38 14.96 518 294 0.29 / 594.38 5 6
2 7 2008.00 40 14.66 3391 1988 2.28 / 596.37 6 21
3 13 1502.24 20 14.69 2688 790 3.07 / 597.16 4 25
4 13 1062.36 20 14.73 2054 605 3.68 / 597.76 4 31
5 13 368.08 20 14.93 984 294 3.97 / 598.06 4 36
6 8 0.00 349 14.98 376 1966 5.94 / 600.02 5 143
Average= 7.14
(KJ/cycle)

Cycle 102 GMT 23/ 9/2024 6:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.32 38 14.95 531 302 0.30 / 588.38 5 5
2 7 2007.16 41 14.65 3392 2037 2.34 / 590.42 5 19
3 13 1578.16 20 14.68 2798 821 3.16 / 591.24 4 25
4 13 1011.48 20 14.76 1959 578 3.74 / 591.82 4 32
5 13 359.72 20 14.95 958 286 4.03 / 592.11 4 35
6 8 -0.04 349 14.98 378 1976 6.00 / 594.08 5 137
Average= 7.16
(KJ/cycle)

Cycle 101 GMT 13/ 9/2024 10:34:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.20 38 14.96 525 298 0.30 / 582.23 5 5
2 7 2008.00 41 14.65 3400 2042 2.34 / 584.27 5 19
3 13 1673.28 20 14.66 2934 860 3.20 / 585.13 4 26
4 13 1070.60 20 14.74 2080 613 3.81 / 585.74 4 33
5 13 477.76 20 14.90 1173 350 4.16 / 586.09 4 37
6 8 0.08 349 14.97 381 1991 6.15 / 588.08 5 133
Average= 7.17
(KJ/cycle)

Cycle 100 GMT 3/ 9/2024 14:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.96 38 14.96 540 307 0.31 / 576.18 5 6
2 7 2004.32 40 14.67 3365 1975 2.28 / 578.16 6 20
3 13 1487.32 20 14.70 2654 780 3.06 / 578.94 4 27
4 13 1156.84 20 14.72 2163 637 3.70 / 579.57 4 30
5 13 544.00 20 14.88 1249 372 4.07 / 579.95 4 38
6 8 0.00 353 14.98 375 1983 6.05 / 581.93 5 154
Average= 7.18
(KJ/cycle)

Cycle 99 GMT 24/ 8/2024 18:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.80 38 14.96 545 310 0.31 / 570.23 5 8
2 7 2005.68 40 14.65 3388 1985 2.30 / 572.21 8 19
3 13 1675.92 20 14.67 2938 862 3.16 / 573.07 4 25
4 13 984.92 20 14.76 1944 574 3.73 / 573.65 4 32
5 13 326.84 20 14.96 918 275 4.01 / 573.92 4 26
6 8 0.12 342 14.98 381 1952 5.96 / 575.88 5 156
Average= 7.20
(KJ/cycle)

Cycle 98 GMT 14/ 8/2024 22:52: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.52 38 14.96 512 291 0.29 / 564.23 5 27
2 7 2005.44 40 14.67 3383 1985 2.28 / 566.21 27 23
3 13 1585.36 20 14.68 2802 823 3.10 / 567.03 4 24
4 13 1008.08 20 14.76 1972 582 3.68 / 567.62 4 33
5 13 434.40 20 14.92 1085 324 4.00 / 567.94 4 32
6 8 -0.08 352 14.98 375 1977 5.98 / 569.92 5 164
Average= 7.21
(KJ/cycle)

Cycle 97 GMT 5/ 8/2024 2:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 38 14.96 525 298 0.30 / 558.21 5 5
2 7 2014.92 41 14.65 3387 2034 2.33 / 560.25 5 19
3 13 1479.36 20 14.70 2659 782 3.11 / 561.03 4 27
4 13 1029.40 20 14.75 2009 593 3.71 / 561.62 4 31
5 13 446.72 20 14.91 1130 337 4.04 / 561.96 4 38
6 8 0.00 349 14.98 378 1976 6.02 / 563.94 5 156
Average= 7.23
(KJ/cycle)

Cycle 96 GMT 26/ 7/2024 6:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.52 38 14.97 524 298 0.30 / 552.30 5 5
2 7 2010.56 40 14.65 3389 1986 2.28 / 554.28 5 19
3 13 1492.36 20 14.70 2670 785 3.07 / 555.07 4 27
4 13 955.32 20 14.77 1900 561 3.63 / 555.63 4 33
5 13 378.24 20 14.94 1000 299 3.93 / 555.93 4 36
6 8 -0.08 347 14.98 382 1986 5.91 / 557.92 5 156
Average= 7.25
(KJ/cycle)

Cycle 95 GMT 16/ 7/2024 10:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.44 38 14.98 520 296 0.30 / 546.21 5 6
2 7 2005.72 41 14.65 3408 2047 2.34 / 548.26 6 19
3 13 1670.92 20 14.67 2942 863 3.21 / 549.12 4 24
4 13 1077.16 20 14.75 2082 614 3.82 / 549.73 4 31
5 13 392.96 20 14.94 1032 308 4.13 / 550.04 4 36
6 8 0.00 346 14.98 378 1959 6.09 / 552.00 5 158
Average= 7.26
(KJ/cycle)

Cycle 94 GMT 6/ 7/2024 14:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.92 38 14.97 520 296 0.30 / 540.29 5 7
2 7 2005.32 41 14.66 3369 2025 2.32 / 542.32 7 20
3 13 1667.28 20 14.68 2909 854 3.17 / 543.17 4 26
4 13 1068.60 20 14.75 2042 602 3.78 / 543.77 4 31
5 13 484.08 20 14.91 1154 344 4.12 / 544.12 4 35
6 8 -0.04 342 15.00 350 1795 5.92 / 545.91 5 132
Average= 7.28
(KJ/cycle)

Cycle 93 GMT 26/ 6/2024 19: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.28 38 14.98 525 299 0.30 / 534.45 5 6
2 7 2020.92 40 14.66 3397 1992 2.29 / 536.44 6 21
3 13 1488.24 20 14.70 2662 783 3.07 / 537.23 4 26
4 13 1046.44 20 14.75 2021 596 3.67 / 537.82 4 31
5 13 363.00 20 14.95 962 288 3.96 / 538.11 4 34
6 8 -0.04 338 14.99 372 1885 5.84 / 540.00 5 141
Average= 7.30
(KJ/cycle)

Cycle 92 GMT 16/ 6/2024 22:52: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.56 38 14.98 503 286 0.29 / 528.51 5 5
2 7 2011.16 40 14.66 3394 1990 2.28 / 530.50 5 20
3 13 1578.84 20 14.68 2807 824 3.10 / 531.33 4 25
4 13 1007.08 20 14.77 1969 582 3.68 / 531.91 4 32
5 13 431.16 20 14.93 1088 325 4.01 / 532.24 4 36
6 13 31.80 20 15.06 414 125 4.13 / 532.36 5 33
7 8 -0.04 319 14.99 375 1793 5.93 / 534.15 5 157
Average= 7.32
(KJ/cycle)

Cycle 91 GMT 7/ 6/2024 2:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.32 38 14.98 514 293 0.29 / 522.67 5 9
2 7 2014.40 40 14.66 3388 1987 2.28 / 524.65 9 20
3 13 1488.52 20 14.70 2676 787 3.07 / 525.44 4 26
4 13 1032.56 20 14.76 2004 592 3.66 / 526.03 4 32
5 13 358.92 20 14.95 963 288 3.95 / 526.32 4 32
6 13 48.64 20 15.05 464 140 4.09 / 526.46 5 37
7 8 -0.08 317 14.99 372 1768 5.85 / 528.23 5 152
Average= 7.34
(KJ/cycle)

Cycle 90 GMT 28/ 5/2024 6:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.96 38 15.00 477 272 0.27 / 516.79 5 5
2 7 2004.60 41 14.66 3369 2025 2.30 / 518.82 5 20
3 13 1561.36 20 14.70 2759 811 3.11 / 519.63 4 27
4 13 891.48 20 14.79 1824 540 3.65 / 520.17 4 32
5 13 333.76 20 14.96 938 281 3.93 / 520.45 4 37
6 13 35.32 20 15.05 449 135 4.06 / 520.59 5 26
7 8 -0.12 317 14.98 377 1790 5.85 / 522.38 5 140
Average= 7.36
(KJ/cycle)

Cycle 89 GMT 18/ 5/2024 10:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.52 38 15.00 480 274 0.27 / 511.07 5 5
2 7 2006.12 40 14.66 3378 1981 2.25 / 513.05 5 20
3 13 1569.56 20 14.69 2780 817 3.07 / 513.86 4 25
4 13 997.88 20 14.77 1950 576 3.65 / 514.44 4 32
5 13 444.92 20 14.92 1105 330 3.98 / 514.77 4 36
6 13 36.44 20 15.06 425 128 4.10 / 514.90 5 23
7 8 0.04 314 15.00 345 1625 5.73 / 516.52 5 142
Average= 7.38
(KJ/cycle)

Cycle 88 GMT 8/ 5/2024 14:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.04 37 14.99 504 280 0.28 / 505.41 5 7
2 7 2010.20 40 14.67 3360 1972 2.25 / 507.38 7 20
3 13 1573.96 20 14.69 2781 817 3.07 / 508.20 4 27
4 13 1095.16 20 14.75 2094 618 3.69 / 508.81 4 31
5 13 304.64 20 14.98 859 257 3.94 / 509.07 4 41
6 13 36.40 20 15.06 420 127 4.07 / 509.20 5 27
7 8 -0.08 310 15.00 343 1595 5.66 / 510.79 5 132
Average= 7.40
(KJ/cycle)

Cycle 87 GMT 28/ 4/2024 18:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.92 38 14.99 521 297 0.30 / 499.60 5 5
2 7 2006.36 40 14.67 3372 1979 2.28 / 501.58 5 19
3 13 1570.64 20 14.69 2785 818 3.09 / 502.40 4 25
4 13 1010.40 20 14.77 1968 581 3.68 / 502.98 4 32
5 13 335.56 20 14.97 916 274 3.95 / 503.26 4 34
6 13 22.08 20 15.07 398 120 4.07 / 503.38 5 35
7 8 -0.08 312 15.00 374 1750 5.82 / 505.13 5 149
Average= 7.43
(KJ/cycle)

Cycle 86 GMT 18/ 4/2024 22:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.64 38 14.99 500 285 0.28 / 493.67 5 7
2 7 2005.36 40 14.66 3388 1987 2.27 / 495.66 7 18
3 13 1663.00 20 14.68 2939 863 3.13 / 496.52 4 23
4 13 1077.12 20 14.76 2056 607 3.74 / 497.13 4 30
5 13 390.64 20 14.95 1024 306 4.05 / 497.43 4 35
6 13 34.28 20 15.06 443 133 4.18 / 497.56 5 11
7 8 -0.04 310 14.99 375 1743 5.92 / 499.31 5 148
Average= 7.45
(KJ/cycle)

Cycle 85 GMT 9/ 4/2024 2:41: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.60 37 14.99 517 287 0.29 / 487.70 5 6
2 7 2011.68 40 14.66 3393 1990 2.28 / 489.69 6 20
3 13 1586.60 20 14.68 2819 828 3.10 / 490.51 4 26
4 13 1123.80 20 14.74 2130 628 3.73 / 491.14 4 30
5 13 514.76 20 14.90 1209 360 4.09 / 491.50 4 34
6 13 52.68 20 15.05 456 137 4.23 / 491.64 5 42
7 8 -0.16 317 14.99 367 1744 5.97 / 493.38 5 156
Average= 7.48
(KJ/cycle)

Cycle 84 GMT 30/ 3/2024 6:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.12 37 14.98 518 287 0.29 / 481.82 5 17
2 7 2004.92 40 14.66 3374 1979 2.27 / 483.80 17 20
3 13 1560.92 20 14.70 2759 811 3.08 / 484.61 4 23
4 13 993.00 20 14.78 1959 579 3.66 / 485.19 4 31
5 13 424.88 20 14.94 1090 326 3.98 / 485.51 4 35
6 13 33.44 20 15.06 441 133 4.11 / 485.64 5 49
7 8 -0.04 310 14.99 380 1766 5.88 / 487.41 5 149
Average= 7.50
(KJ/cycle)

Cycle 83 GMT 20/ 3/2024 10:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.28 37 14.99 509 282 0.28 / 475.89 5 6
2 7 2007.08 40 14.67 3411 2002 2.28 / 477.89 6 21
3 13 1673.00 20 14.68 2919 857 3.14 / 478.75 4 25
4 13 972.20 20 14.78 1945 575 3.72 / 479.33 4 31
5 13 288.12 20 14.99 859 258 3.97 / 479.58 4 32
6 13 30.68 20 15.06 440 133 4.11 / 479.72 5 32
7 8 -0.12 317 14.99 382 1815 5.92 / 481.53 5 138
Average= 7.52
(KJ/cycle)

Cycle 82 GMT 10/ 3/2024 14:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.24 37 14.98 509 282 0.28 / 470.16 5 6
2 7 2009.84 40 14.67 3388 1988 2.27 / 472.15 6 20
3 13 1467.32 20 14.72 2636 776 3.05 / 472.93 4 26
4 13 919.60 20 14.80 1848 547 3.59 / 473.47 4 33
5 13 347.76 20 14.97 936 280 3.87 / 473.76 4 30
6 13 36.60 20 15.06 430 130 4.00 / 473.88 5 37
7 8 -0.12 315 15.00 365 1725 5.73 / 475.61 5 158
Average= 7.55
(KJ/cycle)

Cycle 81 GMT 29/ 2/2024 18:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.52 37 14.98 511 283 0.28 / 464.26 5 5
2 7 2010.64 40 14.66 3401 1994 2.28 / 466.25 5 20
3 13 1485.00 20 14.71 2668 785 3.06 / 467.04 4 28
4 13 928.32 20 14.79 1874 554 3.62 / 467.59 4 33
5 13 452.84 20 14.92 1145 342 3.96 / 467.93 4 38
6 13 34.28 20 15.06 449 135 4.09 / 468.07 5 41
7 8 -0.08 319 14.99 379 1812 5.91 / 469.88 5 145
Average= 7.58
(KJ/cycle)

Cycle 80 GMT 19/ 2/2024 22:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.68 37 15.00 494 274 0.27 / 458.28 5 5
2 7 2013.60 40 14.67 3382 1985 2.26 / 460.26 5 21
3 13 1676.84 20 14.69 2914 856 3.11 / 461.12 4 24
4 13 992.96 20 14.78 1943 574 3.69 / 461.69 4 32
5 13 411.40 20 14.94 1067 319 4.01 / 462.01 4 36
6 13 27.24 20 15.06 442 133 4.14 / 462.15 5 24
7 8 -0.12 317 14.99 385 1829 5.97 / 463.98 5 135
Average= 7.61
(KJ/cycle)

Cycle 79 GMT 10/ 2/2024 3: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.04 37 14.98 508 282 0.28 / 452.47 5 9
2 7 2017.12 40 14.67 3405 1998 2.28 / 454.47 9 22
3 13 1569.04 20 14.70 2780 817 3.10 / 455.29 4 24
4 13 994.04 20 14.78 1968 582 3.68 / 455.87 4 33
5 13 329.92 20 14.97 932 279 3.96 / 456.15 4 33
6 13 21.28 20 15.07 420 127 4.08 / 456.27 5 33
7 8 -0.04 312 15.00 370 1732 5.82 / 458.00 5 145
Average= 7.63
(KJ/cycle)

Cycle 78 GMT 31/ 1/2024 6:50: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.08 37 14.98 523 290 0.29 / 446.58 5 6
2 7 2004.92 41 14.66 3374 2028 2.32 / 448.60 6 19
3 13 1465.68 20 14.72 2646 779 3.10 / 449.38 4 26
4 13 1024.64 20 14.77 2002 591 3.69 / 449.97 4 31
5 13 322.64 20 14.97 920 275 3.96 / 450.25 4 43
6 13 13.60 20 15.07 408 123 4.09 / 450.37 5 17
7 8 -0.16 319 14.99 380 1817 5.90 / 452.19 5 132
Average= 7.66
(KJ/cycle)

Cycle 77 GMT 21/ 1/2024 10:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.56 38 15.00 504 287 0.29 / 440.62 5 7
2 7 2011.56 40 14.67 3389 1989 2.28 / 442.61 7 19
3 13 1572.16 20 14.71 2767 814 3.09 / 443.43 4 25
4 13 1104.20 20 14.76 2099 620 3.71 / 444.05 4 30
5 13 498.28 20 14.91 1192 355 4.07 / 444.40 4 36
6 13 23.60 20 15.07 424 128 4.19 / 444.53 5 20
7 8 -0.04 312 15.00 375 1755 5.95 / 446.29 5 143
Average= 7.69
(KJ/cycle)

Cycle 76 GMT 11/ 1/2024 14:57: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.00 37 14.97 515 285 0.29 / 434.87 5 5
2 7 2014.88 40 14.67 3394 1992 2.28 / 436.86 5 21
3 13 1579.52 20 14.70 2764 813 3.09 / 437.67 4 26
4 13 998.88 20 14.78 1947 576 3.67 / 438.25 4 33
5 13 318.72 20 14.98 889 266 3.93 / 438.52 4 37
6 13 54.16 20 15.07 453 137 4.07 / 438.65 5 29
7 13 33.96 20 15.06 414 125 4.19 / 438.78 5 29
8 8 -0.04 285 15.00 365 1560 5.75 / 440.34 5 138
Average= 7.73
(KJ/cycle)

Cycle 75 GMT 1/ 1/2024 18:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.04 37 14.98 526 292 0.29 / 428.94 5 9
2 7 2005.84 40 14.67 3383 1985 2.28 / 430.93 9 19
3 13 1476.24 20 14.72 2641 778 3.05 / 431.71 4 26
4 13 1034.60 20 14.77 2010 594 3.65 / 432.30 4 30
5 13 441.88 20 14.93 1114 333 3.98 / 432.63 4 37
6 8 0.00 340 14.99 383 1952 5.93 / 434.58 5 142
Average= 7.76
(KJ/cycle)

Cycle 74 GMT 22/12/2023 22:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.24 37 14.99 519 288 0.29 / 423.14 5 7
2 7 2012.40 40 14.67 3384 1986 2.27 / 425.13 7 19
3 13 1479.96 20 14.72 2640 777 3.05 / 425.91 4 25
4 13 1027.40 20 14.78 1983 586 3.64 / 426.49 4 32
5 13 235.44 20 15.02 758 228 3.86 / 426.72 4 33
6 13 19.76 20 15.07 427 129 3.99 / 426.85 5 43
7 8 -0.16 314 15.00 383 1804 5.80 / 428.65 5 133
Average= 7.79
(KJ/cycle)

Cycle 73 GMT 13/12/2023 2:37: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.36 37 14.97 534 296 0.30 / 417.22 5 5
2 7 2005.48 40 14.67 3388 1988 2.28 / 419.20 5 19
3 13 1552.52 20 14.71 2763 813 3.10 / 420.02 4 24
4 13 1075.56 20 14.77 2086 616 3.71 / 420.63 4 30
5 13 337.40 20 14.98 931 279 3.99 / 420.91 4 47
6 8 -0.12 338 15.00 383 1942 5.93 / 422.85 5 149
Average= 7.83
(KJ/cycle)

Cycle 72 GMT 3/12/2023 6:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.44 37 14.97 516 286 0.29 / 411.31 5 7
2 7 2005.88 40 14.68 3358 1972 2.26 / 413.28 7 19
3 13 1578.00 20 14.71 2771 815 3.07 / 414.10 4 25
4 13 1003.88 20 14.78 1974 584 3.66 / 414.68 4 32
5 13 422.72 20 14.95 1060 317 3.97 / 415.00 4 38
6 8 0.00 343 15.01 373 1920 5.89 / 416.92 5 157
Average= 7.87
(KJ/cycle)

Cycle 71 GMT 23/11/2023 10:47:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.88 37 14.98 537 298 0.30 / 405.35 5 7
2 7 2019.24 40 14.68 3387 1989 2.29 / 407.34 7 20
3 13 1568.04 20 14.71 2760 812 3.10 / 408.15 4 27
4 13 994.16 20 14.79 1949 577 3.67 / 408.73 4 32
5 13 422.12 20 14.95 1074 321 4.00 / 409.05 4 36
6 8 -0.04 344 15.00 383 1976 5.97 / 411.03 5 141
Average= 7.90
(KJ/cycle)

Cycle 70 GMT 13/11/2023 14:47: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.64 37 14.99 523 290 0.29 / 399.26 5 8
2 7 2007.40 40 14.67 3410 2001 2.29 / 401.26 8 20
3 13 1668.64 20 14.69 2943 865 3.16 / 402.12 4 24
4 13 1080.00 20 14.78 2061 609 3.76 / 402.73 4 31
5 13 512.88 20 14.92 1217 363 4.13 / 403.09 4 36
6 8 0.00 343 15.01 381 1962 6.09 / 405.05 5 153
Average= 7.94
(KJ/cycle)

Cycle 69 GMT 3/11/2023 18:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.88 37 14.98 520 288 0.29 / 393.38 5 7
2 7 2006.84 40 14.67 3397 1993 2.28 / 395.38 7 20
3 13 1573.28 20 14.71 2781 818 3.10 / 396.19 4 26
4 13 927.52 20 14.81 1858 550 3.65 / 396.74 4 32
5 13 353.88 20 14.97 964 289 3.94 / 397.03 4 35
6 8 -0.08 340 15.00 379 1933 5.87 / 398.97 5 149
Average= 7.98
(KJ/cycle)

Cycle 68 GMT 24/10/2023 22:38:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.20 37 14.98 518 287 0.29 / 387.46 5 6
2 7 2010.56 40 14.69 3393 1994 2.28 / 389.46 6 21
3 13 1463.56 20 14.73 2648 780 3.06 / 390.24 4 28
4 13 933.64 20 14.81 1881 557 3.62 / 390.79 4 33
5 13 465.40 20 14.93 1139 340 3.96 / 391.13 4 37
6 8 -0.12 344 15.00 380 1961 5.92 / 393.09 5 168
Average= 8.02
(KJ/cycle)

Cycle 67 GMT 15/10/2023 2:38: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.16 37 14.99 536 297 0.30 / 381.53 5 7
2 7 2020.96 40 14.69 3391 1993 2.29 / 383.52 7 20
3 13 1591.00 20 14.72 2798 824 3.11 / 384.35 4 26
4 13 1021.68 20 14.79 2001 592 3.71 / 384.94 4 32
5 13 342.40 20 14.98 946 283 3.99 / 385.22 4 40
6 8 -0.20 342 15.01 380 1951 5.94 / 387.17 5 133
Average= 8.07
(KJ/cycle)

Cycle 66 GMT 5/10/2023 6:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.12 37 14.99 519 288 0.29 / 375.76 5 7
2 7 2004.96 40 14.70 3364 1978 2.27 / 377.74 24 19
3 13 1575.16 20 14.72 2754 811 3.08 / 378.55 4 24
4 13 907.08 20 14.82 1821 540 3.62 / 379.09 4 33
5 13 251.44 20 15.02 772 232 3.85 / 379.32 4 30
6 8 0.00 334 15.02 381 1911 5.76 / 381.24 5 144
Average= 8.11
(KJ/cycle)

Cycle 65 GMT 25/ 9/2023 10:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.84 37 15.00 510 283 0.28 / 369.81 5 6
2 7 2006.92 40 14.69 3377 1984 2.27 / 371.79 6 21
3 13 1573.16 20 14.72 2801 825 3.09 / 372.62 4 26
4 13 997.08 20 14.79 1974 584 3.68 / 373.20 4 33
5 13 403.92 20 14.97 1057 316 3.99 / 373.52 4 36
6 8 0.04 344 15.01 379 1957 5.95 / 375.48 5 171
Average= 8.16
(KJ/cycle)

Cycle 64 GMT 15/ 9/2023 14:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.20 37 15.00 525 291 0.29 / 363.96 5 6
2 7 2008.68 40 14.69 3360 1974 2.27 / 365.94 14 19
3 13 1465.32 20 14.74 2610 769 3.04 / 366.71 4 26
4 13 910.92 20 14.82 1850 548 3.58 / 367.26 4 34
5 13 440.56 20 14.95 1106 331 3.91 / 367.59 4 37
6 8 0.12 340 15.01 380 1939 5.85 / 369.53 5 146
Average= 8.21
(KJ/cycle)

Cycle 63 GMT 5/ 9/2023 18:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.52 37 15.01 524 291 0.29 / 358.22 5 6
2 7 2014.84 41 14.70 3377 2035 2.33 / 360.25 6 21
3 13 1490.88 20 14.74 2640 778 3.10 / 361.03 4 27
4 13 940.88 20 14.82 1876 556 3.66 / 361.59 4 33
5 13 247.40 20 15.03 770 231 3.89 / 361.82 4 35
6 8 0.08 334 15.03 369 1852 5.74 / 363.67 5 136
Average= 8.27
(KJ/cycle)

Cycle 62 GMT 26/ 8/2023 22:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.36 37 15.00 538 299 0.30 / 352.37 5 6
2 7 2015.48 40 14.69 3369 1980 2.28 / 354.35 6 21
3 13 1549.80 20 14.74 2736 807 3.08 / 355.16 4 27
4 13 967.16 20 14.82 1905 565 3.65 / 355.73 4 32
5 13 285.60 20 15.02 859 258 3.91 / 355.98 4 32
6 8 -0.08 338 15.02 383 1944 5.85 / 357.93 5 153
Average= 8.32
(KJ/cycle)

Cycle 61 GMT 17/ 8/2023 2:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.52 37 15.01 525 292 0.29 / 346.30 5 7
2 7 2019.72 40 14.69 3397 1996 2.29 / 348.30 7 20
3 13 1586.12 20 14.72 2800 824 3.11 / 349.12 4 25
4 13 1040.68 20 14.80 2028 600 3.71 / 349.72 4 32
5 13 477.84 20 14.95 1165 348 4.06 / 350.07 4 35
6 8 -0.12 342 15.02 390 2003 6.06 / 352.08 5 149
Average= 8.38
(KJ/cycle)

Cycle 60 GMT 7/ 8/2023 6: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.04 37 15.02 534 297 0.30 / 340.33 5 7
2 7 2013.24 40 14.70 3394 1996 2.29 / 342.32 7 21
3 13 1569.96 20 14.74 2773 817 3.11 / 343.14 4 24
4 13 1094.48 20 14.79 2101 621 3.73 / 343.76 4 34
5 13 386.20 20 14.99 1022 306 4.04 / 344.07 4 36
6 8 0.04 338 15.03 383 1946 5.98 / 346.01 5 157
Average= 8.44
(KJ/cycle)

Cycle 59 GMT 28/ 7/2023 10: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.20 37 15.03 526 293 0.29 / 334.43 5 6
2 7 2014.48 40 14.70 3382 1989 2.28 / 336.42 6 22
3 13 1548.28 20 14.74 2750 811 3.09 / 337.23 4 26
4 13 985.76 20 14.83 1941 576 3.67 / 337.81 4 33
5 13 267.96 20 15.04 831 250 3.92 / 338.06 4 30
6 8 -0.04 336 15.03 390 1970 5.89 / 340.03 5 147
Average= 8.50
(KJ/cycle)

Cycle 58 GMT 18/ 7/2023 14: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.32 37 15.03 515 286 0.29 / 328.54 5 5
2 7 2009.48 40 14.71 3368 1982 2.27 / 330.53 5 20
3 13 1568.76 20 14.75 2768 817 3.08 / 331.34 4 26
4 13 1003.16 20 14.83 1954 580 3.66 / 331.92 4 32
5 13 406.28 20 14.99 1037 311 3.98 / 332.23 4 37
6 8 0.00 332 15.05 382 1909 5.88 / 334.14 5 131
Average= 8.57
(KJ/cycle)

Cycle 57 GMT 8/ 7/2023 18:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.76 37 15.03 524 291 0.29 / 322.57 5 6
2 7 2012.36 40 14.72 3376 1988 2.28 / 324.56 6 21
3 13 1581.72 20 14.75 2771 817 3.10 / 325.38 4 26
4 13 1018.20 20 14.82 1993 591 3.69 / 325.97 4 33
5 13 426.88 20 14.99 1084 325 4.01 / 326.30 4 37
6 8 -0.08 338 15.04 386 1962 5.97 / 328.26 5 136
Average= 8.64
(KJ/cycle)

Cycle 56 GMT 28/ 6/2023 22:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.16 37 15.03 537 299 0.30 / 316.63 5 6
2 7 2013.80 40 14.71 3373 1985 2.28 / 318.62 6 20
3 13 1581.24 20 14.74 2804 827 3.11 / 319.44 4 26
4 13 987.76 20 14.84 1926 572 3.68 / 320.01 4 32
5 13 392.32 20 15.01 1021 307 3.99 / 320.32 4 36
6 8 -0.04 338 15.05 386 1964 5.95 / 322.28 5 135
Average= 8.71
(KJ/cycle)

Cycle 55 GMT 19/ 6/2023 2:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.68 37 15.04 533 297 0.30 / 310.69 5 6
2 7 2010.24 40 14.71 3383 1991 2.29 / 312.68 6 21
3 13 1566.72 20 14.75 2779 820 3.11 / 313.50 4 26
4 13 991.72 20 14.84 1964 583 3.69 / 314.08 4 31
5 13 295.00 20 15.05 875 263 3.95 / 314.34 4 35
6 8 -0.24 338 15.05 391 1989 5.94 / 316.33 5 141
Average= 8.79
(KJ/cycle)

Cycle 54 GMT 9/ 6/2023 6:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.04 37 15.05 522 291 0.29 / 304.85 5 6
2 7 2014.44 40 14.72 3361 1979 2.27 / 306.83 6 20
3 13 1540.76 20 14.77 2721 804 3.07 / 307.63 4 28
4 13 962.84 20 14.86 1901 565 3.64 / 308.20 4 33
5 13 281.04 20 15.06 831 250 3.89 / 308.45 4 34
6 8 -0.16 336 15.06 384 1943 5.83 / 310.39 5 134
Average= 8.87
(KJ/cycle)

Cycle 53 GMT 30/ 5/2023 10:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.04 37 15.06 509 284 0.28 / 299.05 5 6
2 7 2009.04 40 14.72 3378 1989 2.27 / 301.04 6 20
3 13 1463.64 20 14.78 2650 783 3.06 / 301.83 4 25
4 13 994.88 20 14.85 1954 580 3.64 / 302.41 4 32
5 13 292.56 20 15.06 872 263 3.90 / 302.67 4 34
6 8 0.00 329 15.07 381 1889 5.79 / 304.56 5 140
Average= 8.96
(KJ/cycle)

Cycle 52 GMT 20/ 5/2023 14:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.04 37 15.07 511 285 0.28 / 293.26 5 6
2 7 2007.24 40 14.72 3382 1991 2.28 / 295.25 6 19
3 13 1559.00 20 14.77 2750 812 3.09 / 296.06 4 25
4 13 972.76 20 14.86 1928 573 3.66 / 296.63 4 33
5 13 278.52 20 15.06 854 257 3.92 / 296.89 4 34
6 8 0.04 327 15.08 381 1879 5.80 / 298.77 5 141
Average= 9.05
(KJ/cycle)

Cycle 51 GMT 10/ 5/2023 18:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.04 37 15.07 511 285 0.28 / 287.46 5 6
2 7 2007.80 41 14.73 3360 2029 2.31 / 289.49 6 21
3 13 1572.16 20 14.77 2781 822 3.14 / 290.31 4 26
4 13 989.76 20 14.86 1974 587 3.72 / 290.90 4 33
5 13 282.52 20 15.07 851 256 3.98 / 291.15 4 35
6 8 -0.04 314 15.08 384 1818 5.80 / 292.97 5 146
Average= 9.16
(KJ/cycle)

Cycle 50 GMT 30/ 4/2023 22:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.44 37 15.07 527 294 0.29 / 281.63 5 5
2 7 2005.84 40 14.72 3383 1992 2.29 / 283.62 5 19
3 13 1567.04 20 14.77 2768 818 3.10 / 284.44 4 26
4 13 1078.28 20 14.84 2089 620 3.72 / 285.06 4 32
5 13 242.32 20 15.09 796 240 3.96 / 285.30 4 35
6 8 0.12 323 15.09 385 1877 5.84 / 287.18 5 133
Average= 9.26
(KJ/cycle)

Cycle 49 GMT 21/ 4/2023 2:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.52 37 15.08 510 285 0.28 / 275.76 5 6
2 7 2004.60 40 14.73 3393 1999 2.28 / 277.76 6 21
3 13 1483.72 20 14.79 2679 792 3.08 / 278.55 4 27
4 13 1032.32 20 14.86 2026 602 3.68 / 279.15 4 31
5 13 338.36 20 15.06 951 286 3.96 / 279.44 4 35
6 13 18.60 20 15.15 427 129 4.09 / 279.57 5 30
7 8 -0.12 308 15.08 380 1765 5.86 / 281.33 5 150
Average= 9.38
(KJ/cycle)

Cycle 48 GMT 11/ 4/2023 6:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.36 37 15.08 522 291 0.29 / 269.93 5 5
2 7 2006.60 40 14.74 3345 1972 2.26 / 271.91 5 21
3 13 1567.32 20 14.79 2774 821 3.08 / 272.73 4 26
4 13 982.52 20 14.88 1951 581 3.66 / 273.31 4 32
5 13 288.04 20 15.08 873 263 3.93 / 273.57 4 35
6 13 34.80 20 15.15 448 136 4.06 / 273.71 5 32
7 8 -0.08 306 15.09 383 1769 5.83 / 275.48 5 144
Average= 9.50
(KJ/cycle)

Cycle 47 GMT 1/ 4/2023 10:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.68 37 15.08 534 298 0.30 / 264.09 5 6
2 7 2013.96 41 14.74 3385 2046 2.34 / 266.13 6 21
3 13 1466.76 20 14.80 2640 781 3.13 / 266.92 4 26
4 13 1003.32 20 14.88 1966 585 3.71 / 267.50 4 31
5 13 313.48 20 15.07 902 272 3.98 / 267.77 4 35
6 8 0.00 327 15.10 379 1871 5.85 / 269.64 5 134
Average= 9.63
(KJ/cycle)

Cycle 46 GMT 22/ 3/2023 14:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.68 37 15.09 532 297 0.30 / 258.20 5 5
2 7 2005.20 40 14.75 3358 1981 2.28 / 260.18 5 22
3 13 1554.04 20 14.80 2752 815 3.09 / 260.99 4 26
4 13 1085.24 20 14.86 2102 625 3.72 / 261.62 4 32
5 13 365.20 20 15.06 989 298 4.02 / 261.92 4 37
6 13 21.72 20 15.16 426 129 4.14 / 262.05 5 29
7 8 -0.04 308 15.10 375 1744 5.89 / 263.79 5 144
Average= 9.77
(KJ/cycle)

Cycle 45 GMT 12/ 3/2023 18:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.04 37 15.08 534 298 0.30 / 252.32 5 5
2 7 2015.52 40 14.74 3395 2002 2.30 / 254.32 5 21
3 13 1578.52 20 14.79 2802 829 3.13 / 255.15 4 26
4 13 921.64 20 14.91 1853 553 3.68 / 255.70 4 33
5 13 349.48 20 15.07 963 290 3.97 / 255.99 4 37
6 8 0.04 329 15.10 384 1908 5.88 / 257.90 5 138
Average= 9.92
(KJ/cycle)

Cycle 44 GMT 2/ 3/2023 22:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.80 37 15.10 510 285 0.28 / 246.35 5 6
2 7 2015.24 40 14.74 3399 2004 2.29 / 248.36 6 20
3 13 1590.48 20 14.80 2795 827 3.12 / 249.18 4 26
4 13 1000.72 20 14.89 1970 587 3.70 / 249.77 4 32
5 13 306.20 20 15.09 898 271 3.97 / 250.04 4 36
6 13 17.36 20 15.18 416 126 4.10 / 250.17 5 28
7 8 -0.08 319 15.10 385 1855 5.95 / 252.02 5 135
Average= 10.08
(KJ/cycle)

Cycle 43 GMT 21/ 2/2023 2:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.52 37 15.09 515 288 0.29 / 240.63 5 6
2 7 2020.84 40 14.73 3412 2010 2.30 / 242.64 6 20
3 13 1475.60 20 14.81 2686 796 3.09 / 243.44 4 27
4 13 926.92 20 14.92 1857 554 3.65 / 243.99 4 32
5 13 246.12 20 15.12 791 239 3.89 / 244.23 4 34
6 8 0.04 329 15.12 369 1836 5.72 / 246.07 5 137
Average= 10.25
(KJ/cycle)

Cycle 42 GMT 11/ 2/2023 6:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.68 37 15.11 513 287 0.29 / 234.79 5 5
2 7 2014.28 41 14.74 3372 2038 2.32 / 236.83 5 20
3 13 1469.52 20 14.84 2570 763 3.09 / 237.59 4 28
4 13 1005.48 20 14.90 1956 583 3.67 / 238.17 4 32
5 13 304.28 20 15.10 863 261 3.93 / 238.44 4 36
6 8 -0.08 336 15.12 376 1910 5.84 / 240.35 5 155
Average= 10.45
(KJ/cycle)

Cycle 41 GMT 1/ 2/2023 10:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.24 37 15.10 519 290 0.29 / 228.94 5 5
2 7 2016.96 41 14.75 3399 2056 2.35 / 231.00 5 21
3 13 1574.00 20 14.80 2813 833 3.18 / 231.83 4 25
4 13 868.76 20 14.94 1788 534 3.71 / 232.36 4 33
5 13 296.48 20 15.10 882 266 3.98 / 232.63 4 36
6 8 0.04 334 15.12 371 1874 5.85 / 234.50 5 139
Average= 10.66
(KJ/cycle)

Cycle 40 GMT 22/ 1/2023 14:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.28 37 15.11 523 292 0.29 / 223.14 5 5
2 7 2007.08 40 14.76 3353 1980 2.27 / 225.12 5 21
3 13 1547.80 20 14.81 2757 817 3.09 / 225.93 4 27
4 13 966.44 20 14.92 1922 574 3.66 / 226.51 4 33
5 13 275.80 20 15.12 840 254 3.92 / 226.76 4 35
6 8 -0.08 338 15.13 370 1892 5.81 / 228.65 5 139
Average= 10.89
(KJ/cycle)

Cycle 39 GMT 12/ 1/2023 18:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.56 37 15.11 507 283 0.28 / 217.26 5 6
2 7 2008.16 41 14.76 3353 2029 2.31 / 219.29 6 20
3 13 1551.20 20 14.82 2748 815 3.13 / 220.11 4 25
4 13 981.64 20 14.92 1933 577 3.70 / 220.68 4 33
5 13 282.60 20 15.12 852 258 3.96 / 220.94 4 37
6 8 0.00 336 15.13 374 1901 5.86 / 222.84 5 146
Average= 11.14
(KJ/cycle)

Cycle 38 GMT 2/ 1/2023 22:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.44 37 15.10 535 299 0.30 / 211.49 5 6
2 7 2016.72 40 14.76 3368 1988 2.29 / 213.48 6 22
3 13 1561.12 20 14.83 2761 819 3.11 / 214.30 4 26
4 13 878.52 20 14.96 1781 533 3.64 / 214.83 4 33
5 13 315.76 20 15.11 911 275 3.91 / 215.10 4 37
6 8 -0.04 338 15.13 367 1877 5.79 / 216.98 5 139
Average= 11.42
(KJ/cycle)

Cycle 37 GMT 24/12/2022 2:25: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.24 37 15.11 529 296 0.30 / 205.53 5 6
2 7 2004.56 40 14.77 3355 1982 2.28 / 207.52 6 21
3 13 1565.20 20 14.83 2748 815 3.09 / 208.33 4 25
4 13 971.28 20 14.94 1884 563 3.66 / 208.89 4 33
5 13 384.64 20 15.09 1022 308 3.96 / 209.20 4 38
6 8 -0.08 342 15.13 384 1987 5.95 / 211.19 5 139
Average= 11.73
(KJ/cycle)

Cycle 36 GMT 14/12/2022 6:30:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.56 37 15.10 533 298 0.30 / 199.64 5 6
2 7 2004.28 40 14.77 3334 1970 2.27 / 201.61 6 20
3 13 1549.08 20 14.83 2749 815 3.08 / 202.42 4 25
4 13 966.52 20 14.94 1922 574 3.66 / 203.00 4 33
5 13 280.56 20 15.13 846 256 3.91 / 203.25 4 36
6 8 0.04 338 15.14 388 1986 5.90 / 205.24 5 138
Average= 12.07
(KJ/cycle)

Cycle 35 GMT 4/12/2022 10:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.80 37 15.11 527 295 0.29 / 193.58 5 6
2 7 2004.56 40 14.78 3364 1989 2.28 / 195.57 6 20
3 13 1565.16 20 14.83 2791 828 3.11 / 196.40 4 27
4 13 1081.44 20 14.91 2079 620 3.73 / 197.02 4 31
5 13 365.24 20 15.10 990 299 4.03 / 197.32 4 38
6 8 0.04 344 15.13 388 2019 6.05 / 199.34 5 136
Average= 12.46
(KJ/cycle)

Cycle 34 GMT 24/11/2022 14:41: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.52 37 15.12 534 299 0.30 / 187.74 5 6
2 7 2012.56 40 14.77 3355 1982 2.28 / 189.72 6 20
3 13 1463.72 20 14.86 2599 772 3.05 / 190.49 4 27
4 13 1000.28 20 14.93 1973 589 3.64 / 191.08 4 33
5 13 212.24 20 15.16 742 225 3.87 / 191.30 4 35
6 8 0.00 338 15.14 388 1986 5.85 / 193.29 5 130
Average= 12.89
(KJ/cycle)

Cycle 33 GMT 14/11/2022 18:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.72 37 15.11 533 298 0.30 / 181.84 5 7
2 7 2003.60 40 14.77 3371 1992 2.29 / 183.83 7 21
3 13 1551.36 20 14.84 2755 818 3.11 / 184.65 4 27
4 13 984.80 20 14.94 1950 583 3.69 / 185.23 4 34
5 13 198.76 20 15.17 715 217 3.91 / 185.44 4 35
6 8 0.04 340 15.14 387 1992 5.90 / 187.44 5 144
Average= 13.39
(KJ/cycle)

Cycle 32 GMT 4/11/2022 22:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.04 37 15.11 545 305 0.30 / 175.71 5 7
2 7 2007.88 41 14.77 3387 2051 2.36 / 177.76 7 22
3 13 1546.00 20 14.85 2755 818 3.17 / 178.58 4 26
4 13 971.12 20 14.95 1939 580 3.75 / 179.16 4 33
5 13 462.00 20 15.07 1159 349 4.10 / 179.51 4 38
6 8 0.04 349 15.14 384 2029 6.13 / 181.54 5 147
Average= 13.96
(KJ/cycle)

Cycle 31 GMT 26/10/2022 2:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.32 37 15.12 537 300 0.30 / 169.76 5 7
2 7 2005.68 40 14.79 3387 2004 2.30 / 171.76 7 21
3 13 1462.12 20 14.86 2644 786 3.09 / 172.55 4 27
4 13 917.08 20 14.96 1853 554 3.64 / 173.10 4 34
5 13 334.44 20 15.12 950 287 3.93 / 173.39 4 36
6 8 0.28 349 15.14 382 2018 5.95 / 175.41 5 140
Average= 14.62
(KJ/cycle)

Cycle 30 GMT 16/10/2022 6:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.56 37 15.12 547 306 0.31 / 163.81 5 7
2 7 2018.48 41 14.78 3387 2052 2.36 / 165.86 7 20
3 13 1465.40 20 14.88 2608 776 3.13 / 166.63 4 27
4 13 994.44 20 14.94 1971 589 3.72 / 167.22 4 33
5 13 225.48 20 15.16 780 236 3.96 / 167.46 4 35
6 8 -0.04 336 15.15 392 1995 5.96 / 169.46 5 137
Average= 15.41
(KJ/cycle)

Cycle 29 GMT 6/10/2022 10:35:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.24 36 15.12 547 298 0.30 / 157.69 5 7
2 7 2017.44 40 14.78 3385 2001 2.30 / 159.69 7 20
3 13 1574.80 20 14.85 2789 828 3.13 / 160.52 4 26
4 13 970.00 20 14.95 1927 576 3.70 / 161.10 4 34
5 13 385.88 20 15.11 1045 316 4.02 / 161.41 4 38
6 8 -0.04 344 15.14 401 2088 6.11 / 163.50 5 160
Average= 16.35
(KJ/cycle)

Cycle 28 GMT 26/ 9/2022 14:46: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.96 36 15.12 546 297 0.30 / 151.68 5 7
2 7 2005.44 41 14.79 3388 2054 2.35 / 153.74 7 20
3 13 1549.84 20 14.86 2766 822 3.17 / 154.56 4 27
4 13 963.92 20 14.96 1928 577 3.75 / 155.13 4 33
5 13 281.92 20 15.15 860 261 4.01 / 155.40 4 36
6 8 -0.04 338 15.15 390 1997 6.01 / 157.39 5 131
Average= 17.49
(KJ/cycle)

Cycle 27 GMT 16/ 9/2022 18:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.92 36 15.14 553 301 0.30 / 145.63 5 7
2 7 2011.12 40 14.80 3352 1984 2.29 / 147.61 7 20
3 13 1479.16 20 14.88 2642 786 3.07 / 148.40 4 28
4 13 931.76 20 14.97 1883 564 3.64 / 148.96 4 34
5 13 465.96 20 15.08 1168 352 3.99 / 149.31 4 38
6 8 -0.04 346 15.15 395 2071 6.06 / 151.38 5 141
Average= 18.92
(KJ/cycle)

Cycle 26 GMT 6/ 9/2022 22:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.68 36 15.15 547 298 0.30 / 139.64 5 7
2 7 2005.40 40 14.80 3364 1991 2.29 / 141.63 7 22
3 13 1560.64 20 14.87 2767 823 3.11 / 142.45 4 26
4 13 987.44 20 14.96 1977 592 3.70 / 143.05 4 34
5 13 296.12 20 15.15 892 270 3.97 / 143.32 4 36
6 8 0.00 334 15.16 397 2010 5.98 / 145.33 5 152
Average= 20.76
(KJ/cycle)

Cycle 25 GMT 28/ 8/2022 2:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.40 36 15.15 525 286 0.29 / 133.72 5 6
2 7 2005.44 40 14.80 3392 2008 2.29 / 135.72 6 20
3 13 1456.96 20 14.90 2605 776 3.07 / 136.50 4 27
4 13 1010.00 20 14.96 1990 595 3.67 / 137.10 4 32
5 13 314.88 20 15.15 908 275 3.94 / 137.37 4 37
6 8 -0.16 340 15.17 382 1970 5.91 / 139.34 5 157
Average= 23.22
(KJ/cycle)

Cycle 24 GMT 18/ 8/2022 6:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.92 36 15.15 549 299 0.30 / 127.80 5 7
2 7 2006.72 40 14.80 3403 2015 2.31 / 129.82 7 20
3 13 1552.84 20 14.88 2746 817 3.13 / 130.64 4 27
4 13 884.28 20 14.99 1822 546 3.68 / 131.18 4 35
5 13 300.80 20 15.15 900 273 3.95 / 131.46 4 38
6 8 0.00 338 15.17 385 1974 5.92 / 133.43 5 138
Average= 26.69
(KJ/cycle)

Cycle 23 GMT 8/ 8/2022 10:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.36 36 15.14 549 299 0.30 / 121.82 5 7
2 7 2016.04 40 14.81 3416 2024 2.32 / 123.85 7 20
3 13 1463.12 20 14.89 2660 792 3.12 / 124.64 4 28
4 13 1006.52 20 14.96 1998 598 3.71 / 125.24 4 33
5 13 317.32 20 15.15 931 282 3.99 / 125.52 4 36
6 8 0.00 334 15.17 392 1986 5.98 / 127.51 5 132
Average= 31.88
(KJ/cycle)

Cycle 22 GMT 29/ 7/2022 14:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.56 36 15.15 541 295 0.30 / 115.86 5 7
2 7 2004.80 40 14.81 3373 1998 2.29 / 117.85 7 21
3 13 1439.48 20 14.90 2622 781 3.07 / 118.64 4 28
4 13 985.52 20 14.97 1976 592 3.67 / 119.23 4 32
5 13 268.24 20 15.17 856 260 3.93 / 119.49 4 37
6 8 -0.04 334 15.17 402 2037 5.96 / 121.52 5 140
Average= 40.51
(KJ/cycle)

Cycle 21 GMT 19/ 7/2022 18:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.40 36 15.16 535 292 0.29 / 109.91 5 6
2 7 2014.96 40 14.81 3409 2019 2.31 / 111.93 6 21
3 13 1569.80 20 14.88 2805 835 3.15 / 112.76 4 26
4 13 867.52 20 15.01 1808 543 3.69 / 113.31 4 35
5 13 194.72 20 15.20 737 224 3.91 / 113.53 4 33
6 8 -0.20 334 15.17 401 2032 5.94 / 115.56 5 138
Average= 57.78
(KJ/cycle)

Cycle 20 GMT 9/ 7/2022 22:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 36 15.17 518 283 0.28 / 104.02 5 6
2 7 2006.92 40 14.82 3372 1999 2.28 / 106.02 6 22
3 13 1557.48 20 14.90 2775 827 3.11 / 106.85 4 27
4 13 882.08 20 15.01 1825 548 3.66 / 107.40 4 34
5 13 233.08 20 15.19 792 241 3.90 / 107.64 4 35
6 8 0.16 332 15.18 393 1981 5.88 / 109.62 5 136
Average= 109.62
(KJ/cycle)

Cycle 18 GMT 20/ 6/2022 6:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.28 36 15.17 526 287 0.29 / 98.23 5 6
2 7 2016.32 40 14.83 3385 2008 2.30 / 100.24 6 23
3 13 1478.36 20 14.90 2697 804 3.10 / 101.04 4 26
4 13 913.36 20 15.00 1849 555 3.65 / 101.60 4 34
5 13 241.92 20 15.19 803 244 3.90 / 101.84 4 37
6 8 -0.04 329 15.19 380 1899 5.80 / 103.74 5 143
Average= 5.46
(KJ/cycle)

Cycle 17 GMT 10/ 6/2022 10:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.84 36 15.17 540 295 0.29 / 92.34 5 6
2 7 2007.28 40 14.84 3365 1997 2.29 / 94.33 6 21
3 13 1480.44 20 14.92 2650 791 3.08 / 95.12 4 28
4 13 941.04 20 15.00 1916 575 3.66 / 95.70 4 34
5 13 363.32 20 15.15 1013 307 3.96 / 96.01 4 38
6 8 -0.04 332 15.19 384 1937 5.90 / 97.94 5 136
Average= 5.44
(KJ/cycle)

Cycle 16 GMT 31/ 5/2022 14:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.00 36 15.18 522 285 0.29 / 86.36 5 6
2 7 2008.76 40 14.84 3378 2005 2.29 / 88.37 6 21
3 13 1460.64 20 14.93 2626 784 3.07 / 89.15 4 28
4 13 913.64 20 15.01 1869 561 3.64 / 89.71 4 33
5 13 441.20 20 15.13 1137 344 3.98 / 90.06 4 38
6 8 0.00 334 15.19 391 1984 5.96 / 92.04 5 146
Average= 5.41
(KJ/cycle)

Cycle 15 GMT 21/ 5/2022 18:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.00 36 15.18 515 281 0.28 / 80.43 5 6
2 7 2004.48 40 14.84 3376 2004 2.29 / 82.44 6 20
3 13 1561.00 20 14.92 2746 819 3.10 / 83.25 4 27
4 13 886.92 20 15.02 1829 549 3.65 / 83.80 4 34
5 13 409.68 20 15.14 1090 330 3.98 / 84.13 4 39
6 8 0.00 332 15.20 385 1943 5.93 / 86.08 5 142
Average= 5.38
(KJ/cycle)

Cycle 14 GMT 11/ 5/2022 22:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.12 36 15.19 528 289 0.29 / 74.39 5 6
2 7 2015.16 40 14.84 3409 2024 2.31 / 76.42 6 20
3 13 1558.44 20 14.91 2804 836 3.15 / 77.25 4 27
4 13 983.16 20 15.00 1972 592 3.74 / 77.84 4 33
5 13 400.64 20 15.15 1080 327 4.07 / 78.17 4 38
6 8 0.04 332 15.20 392 1978 6.05 / 80.15 5 132
Average= 5.34
(KJ/cycle)

Cycle 13 GMT 2/ 5/2022 2:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.40 36 15.18 539 295 0.29 / 68.55 5 5
2 7 2005.68 41 14.84 3396 2066 2.36 / 70.61 5 20
3 13 1459.12 20 14.94 2637 788 3.15 / 71.40 4 27
4 13 889.12 20 15.03 1827 549 3.70 / 71.95 4 34
5 13 207.28 20 15.22 761 232 3.93 / 72.18 4 36
6 8 0.00 321 15.20 394 1922 5.85 / 74.10 5 142
Average= 5.29
(KJ/cycle)

Cycle 12 GMT 22/ 4/2022 6:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.56 36 15.19 529 289 0.29 / 62.58 5 5
2 7 2004.60 40 14.86 3389 2014 2.30 / 64.59 20 21
3 13 1463.28 20 14.94 2637 788 3.09 / 65.38 4 28
4 13 918.84 20 15.02 1874 563 3.65 / 65.94 4 34
5 13 429.08 20 15.14 1123 340 3.99 / 66.28 4 39
6 8 -0.04 323 15.20 401 1969 5.96 / 68.25 5 139
Average= 5.25
(KJ/cycle)

Cycle 11 GMT 12/ 4/2022 10:20: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.68 36 15.19 524 287 0.29 / 56.75 5 5
2 7 2018.96 40 14.86 3399 2020 2.31 / 58.77 5 22
3 13 1461.68 20 14.93 2665 796 3.10 / 59.57 4 27
4 13 890.16 20 15.03 1816 546 3.65 / 60.11 4 33
5 13 284.24 20 15.20 882 268 3.92 / 60.38 4 37
6 8 -0.08 323 15.21 388 1906 5.82 / 62.29 5 137
Average= 5.19
(KJ/cycle)

Cycle 10 GMT 2/ 4/2022 14:20: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.04 36 15.20 532 291 0.29 / 50.76 5 5
2 7 2016.76 40 14.86 3391 2016 2.31 / 52.78 5 21
3 13 1562.04 20 14.93 2775 829 3.14 / 53.61 4 25
4 13 980.60 20 15.02 1949 585 3.72 / 54.19 4 33
5 13 381.36 20 15.17 1041 316 4.04 / 54.51 4 38
6 13 19.80 20 15.28 431 132 4.17 / 54.64 5 28
7 8 -0.12 308 15.20 390 1826 5.99 / 56.47 5 135
Average= 5.13
(KJ/cycle)

Cycle 9 GMT 23/ 3/2022 18:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.52 36 15.21 517 283 0.28 / 45.03 5 5
2 7 2004.48 40 14.86 3373 2005 2.29 / 47.03 5 21
3 13 1550.36 20 14.94 2757 824 3.11 / 47.86 4 26
4 13 853.52 20 15.05 1794 540 3.65 / 48.40 4 33
5 13 178.72 20 15.24 698 213 3.86 / 48.61 4 34
6 8 -0.04 323 15.22 379 1863 5.73 / 50.47 5 153
Average= 5.05
(KJ/cycle)

Cycle 8 GMT 13/ 3/2022 22:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.20 35 15.21 511 272 0.27 / 39.20 5 5
2 7 2018.20 40 14.87 3411 2029 2.30 / 41.23 5 21
3 13 1451.36 20 14.96 2615 782 3.08 / 42.01 4 26
4 13 1001.00 20 15.01 1997 599 3.68 / 42.61 4 33
5 13 290.56 20 15.20 886 269 3.95 / 42.88 4 37
6 8 -0.08 323 15.22 380 1868 5.82 / 44.74 5 137
Average= 4.97
(KJ/cycle)

Cycle 7 GMT 4/ 3/2022 2:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.72 35 15.21 522 278 0.28 / 33.33 5 5
2 3 1028.44 1 15.22 2047 31 0.31 / 33.36 4 25
3 7 2006.56 40 14.87 3370 2004 2.31 / 35.37 25 21
4 13 1570.20 20 14.94 2796 835 3.15 / 36.20 4 26
5 13 972.40 20 15.02 1966 591 3.74 / 36.79 4 33
6 13 259.68 20 15.21 836 254 3.99 / 37.05 4 35
7 13 23.60 20 15.28 434 133 4.13 / 37.18 5 31
8 8 0.00 300 15.22 382 1744 5.87 / 38.92 5 139
Average= 4.87
(KJ/cycle)

Cycle 6 GMT 22/ 2/2022 6:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.00 34 15.20 537 278 0.28 / 27.46 5 5
2 3 1033.16 1 15.22 2050 31 0.31 / 27.49 4 24
3 7 2017.00 41 14.87 3424 2088 2.40 / 29.58 24 19
4 13 1432.00 20 14.97 2609 781 3.18 / 30.36 4 28
5 13 867.56 20 15.05 1797 541 3.72 / 30.90 4 34
6 13 276.28 20 15.21 859 261 3.98 / 31.17 4 37
7 13 22.32 20 15.28 433 132 4.11 / 31.30 5 28
8 8 -0.04 302 15.22 382 1756 5.87 / 33.05 5 136
Average= 4.72
(KJ/cycle)

Cycle 5 GMT 12/ 2/2022 10:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.56 31 15.21 532 251 0.25 / 21.50 5 5
2 10 1051.00 4 15.16 2048 124 0.38 / 21.62 4 16
3 7 2004.56 40 14.89 3402 2026 2.40 / 23.65 16 19
4 13 1539.68 20 14.95 2760 825 3.23 / 24.48 4 26
5 13 945.56 20 15.04 1920 578 3.80 / 25.05 4 34
6 13 248.36 20 15.22 830 253 4.06 / 25.31 4 36
7 8 0.08 319 15.23 387 1880 5.94 / 27.19 5 136
Average= 4.53
(KJ/cycle)

Cycle 4 GMT 2/ 2/2022 14:26: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.80 34 15.21 514 266 0.27 / 16.22 5 5
2 7 1510.32 41 15.02 2715 1672 1.94 / 17.89 5 24
3 13 1411.52 20 15.03 2564 771 2.71 / 18.66 4 28
4 13 800.12 20 15.11 1700 514 3.22 / 19.17 4 34
5 13 206.32 20 15.26 751 229 3.45 / 19.40 4 36
6 8 0.04 314 15.24 386 1847 5.30 / 21.25 5 143
Average= 4.25
(KJ/cycle)

Cycle 3 GMT 1/ 2/2022 4:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.88 34 15.22 519 269 0.27 / 10.93 5 6
2 7 1524.60 41 15.02 2727 1679 1.95 / 12.60 17 25
3 13 1427.68 20 15.02 2589 778 2.73 / 13.38 4 27
4 13 921.92 20 15.09 1863 562 3.29 / 13.94 4 34
5 13 86.04 20 15.30 549 168 3.46 / 14.11 5 32
6 8 0.04 314 15.24 384 1838 5.29 / 15.95 5 154
Average= 3.99
(KJ/cycle)

Cycle 2 GMT 30/ 1/2022 19:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.00 31 15.27 528 250 0.25 / 5.70 5 5
2 10 1041.48 4 15.19 1996 121 0.37 / 5.83 5 14
3 7 1507.72 41 15.04 2697 1663 2.03 / 7.49 14 24
4 13 1223.56 20 15.06 2308 695 2.73 / 8.18 4 28
5 13 758.08 20 15.12 1640 496 3.23 / 8.68 4 34
6 13 66.68 20 15.30 517 158 3.38 / 8.84 5 32
7 8 -0.04 310 15.24 385 1819 5.20 / 10.66 5 138
Average= 3.55
(KJ/cycle)

Cycle 1 GMT 29/ 1/2022 10:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.24 31 15.44 463 222 0.22 / 2.18 5 5
2 10 1016.80 4 15.25 1979 121 0.34 / 2.30 5 13
3 7 974.56 41 15.16 1925 1197 1.54 / 3.50 13 31
4 13 81.92 20 15.37 530 163 1.70 / 3.66 5 32
5 8 0.04 310 15.32 378 1795 3.50 / 5.45 5 134
Average= 2.73
(KJ/cycle)

Cycle 0 GMT 28/ 1/2022 23:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 135.88 30 15.61 508 238 0.24 / 0.24 5 5
2 7 150.60 40 15.59 517 322 0.56 / 0.56 5 6
3 13 77.72 20 15.58 407 127 0.69 / 0.69 5 8
4 8 0.04 287 15.53 285 1270 1.96 / 1.96 5 149
Average= 1.96
(KJ/cycle)