SIO Argo Site:
Pump Diagnostics Page   



Serial= 7750 WMO= 1902425

Return

←PreviousNext→

Cycle 5 GMT 11/ 1/2022 2:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.64 31 15.17 488 229 0.23 / 23.56 5 8
2 3 1073.32 2 15.15 2064 63 0.29 / 23.62 5 27
3 7 2010.80 40 14.79 3423 2025 2.32 / 25.65 27 25
4 13 1915.32 20 14.79 3268 967 3.28 / 26.61 5 29
5 13 1724.92 20 14.77 3004 887 4.17 / 27.50 5 33
6 13 894.64 20 14.97 1791 536 4.71 / 28.04 5 41
7 13 101.20 20 15.23 536 163 4.87 / 28.20 5 36
8 13 28.92 20 15.26 389 119 4.99 / 28.32 5 15
9 8 0.00 400 15.17 348 2112 7.10 / 30.43 5 42
Average= 5.07
(KJ/cycle)

Cycle 4 GMT 1/ 1/2022 5: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.76 32 15.17 481 233 0.23 / 17.58 5 8
2 3 1023.56 1 15.20 1946 30 0.26 / 17.61 5 14
3 7 1519.64 40 14.98 2682 1607 1.87 / 19.21 14 28
4 13 1447.76 20 14.96 2584 773 2.64 / 19.99 5 31
5 13 1246.08 20 14.96 2277 681 3.32 / 20.67 5 34
6 13 562.76 20 15.11 1264 382 3.71 / 21.05 5 40
7 13 56.72 20 15.27 441 135 3.84 / 21.19 5 27
8 13 33.48 20 15.26 395 121 3.96 / 21.31 5 20
9 8 0.04 400 15.19 333 2023 5.99 / 23.33 5 61
Average= 4.67
(KJ/cycle)

Cycle 3 GMT 30/12/2021 18:51: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.32 32 15.16 468 227 0.23 / 11.73 5 8
2 7 1518.92 40 14.98 2677 1604 1.83 / 13.34 7 28
3 13 1443.80 20 14.96 2564 767 2.60 / 14.10 5 31
4 13 1149.00 20 14.97 2143 642 3.24 / 14.74 5 35
5 13 503.96 20 15.12 1172 354 3.59 / 15.10 5 41
6 13 50.80 20 15.26 423 129 3.72 / 15.23 5 23
7 13 30.60 20 15.26 382 117 3.84 / 15.34 5 16
8 8 -0.08 400 15.19 329 1999 5.84 / 17.34 6 36
Average= 4.34
(KJ/cycle)

Cycle 2 GMT 29/12/2021 8:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.80 31 15.18 458 216 0.22 / 5.95 5 8
2 3 1035.40 1 15.19 1981 30 0.25 / 5.98 5 22
3 7 1510.12 40 14.98 2669 1599 1.84 / 7.58 22 26
4 13 1444.12 20 14.96 2570 769 2.61 / 8.35 5 29
5 13 1142.44 20 14.97 2127 637 3.25 / 8.99 5 34
6 13 588.92 20 15.09 1297 391 3.64 / 9.38 5 39
7 13 67.96 20 15.25 451 138 3.78 / 9.52 5 27
8 8 0.36 400 15.19 327 1987 5.77 / 11.50 5 38
Average= 3.83
(KJ/cycle)

Cycle 1 GMT 27/12/2021 22:10:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.76 31 15.43 425 203 0.20 / 1.91 5 7
2 3 1033.08 1 15.23 1983 30 0.23 / 1.94 5 19
3 7 1017.08 40 15.10 1927 1164 1.40 / 3.11 19 32
4 13 697.84 20 15.16 1448 439 1.84 / 3.55 5 36
5 13 61.64 20 15.31 431 132 1.97 / 3.68 5 24
6 13 33.60 20 15.31 379 116 2.08 / 3.80 5 15
7 8 0.08 400 15.23 319 1943 4.03 / 5.74 5 33
Average= 2.87
(KJ/cycle)

Cycle 0 GMT 27/12/2021 11:25: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 84.08 30 15.59 390 182 0.18 / 0.18 5 9
2 7 92.48 40 15.58 399 249 0.43 / 0.43 9 9
3 13 70.12 20 15.56 377 117 0.55 / 0.55 5 10
4 13 46.72 20 15.55 342 106 0.65 / 0.65 5 10
5 8 0.12 259 15.50 263 1056 1.71 / 1.71 5 135
Average= 1.71
(KJ/cycle)