SIO Argo Site:
Pump Diagnostics Page   



Serial= 7677 WMO= 1902410

Return

←PreviousNext→

Cycle 108 GMT 25/11/2024 14:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.56 39 14.95 448 261 0.26 / 602.46 6 21
2 7 2008.04 40 14.64 3129 1832 2.09 / 604.30 21 49
3 13 1933.16 20 14.62 3033 887 2.98 / 605.18 5 54
4 13 1433.64 20 14.65 2372 695 3.68 / 605.88 5 64
5 13 932.60 20 14.73 1700 501 4.18 / 606.38 5 73
6 13 381.12 20 14.89 904 269 4.45 / 606.65 5 72
7 8 0.16 267 14.96 305 1218 5.66 / 607.87 6 139
Average= 6.83
(KJ/cycle)

Cycle 107 GMT 15/11/2024 17:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.28 39 14.96 453 264 0.26 / 596.75 6 20
2 7 2006.76 41 14.64 3130 1879 2.14 / 598.63 20 51
3 13 1921.96 20 14.62 3007 879 3.02 / 599.51 5 55
4 13 1494.76 20 14.63 2436 713 3.74 / 600.22 5 63
5 13 950.88 20 14.73 1704 502 4.24 / 600.73 5 67
6 13 400.32 20 14.89 928 276 4.51 / 601.00 5 75
7 8 -0.08 267 14.96 300 1198 5.71 / 602.20 6 134
Average= 6.84
(KJ/cycle)

Cycle 106 GMT 5/11/2024 20:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.80 39 14.95 445 259 0.26 / 591.00 6 20
2 7 2015.40 41 14.64 3127 1877 2.14 / 592.87 20 52
3 13 1928.32 20 14.62 3011 880 3.02 / 593.76 5 54
4 13 1513.76 20 14.62 2459 719 3.74 / 594.47 5 63
5 13 1060.88 20 14.70 1835 539 4.28 / 595.01 5 65
6 13 390.24 20 14.89 906 270 4.55 / 595.28 5 75
7 8 0.00 267 14.96 302 1206 5.75 / 596.49 6 139
Average= 6.86
(KJ/cycle)

Cycle 105 GMT 26/10/2024 23:50: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.24 39 14.95 454 265 0.26 / 585.35 6 18
2 7 2006.60 41 14.64 3129 1878 2.14 / 587.23 18 51
3 13 1916.40 20 14.63 2998 877 3.02 / 588.11 5 53
4 13 1408.28 20 14.65 2308 676 3.70 / 588.79 5 60
5 13 896.08 20 14.74 1629 480 4.18 / 589.27 5 72
6 13 342.36 20 14.91 850 253 4.43 / 589.52 5 73
7 8 -0.08 263 14.96 310 1220 5.65 / 590.74 6 132
Average= 6.87
(KJ/cycle)

Cycle 104 GMT 17/10/2024 2:50: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.56 39 14.96 442 258 0.26 / 579.70 6 22
2 7 2008.16 40 14.64 3126 1831 2.09 / 581.53 22 51
3 13 1923.48 20 14.62 3004 878 2.97 / 582.41 5 58
4 13 1416.28 20 14.65 2321 680 3.65 / 583.09 5 64
5 13 980.00 20 14.72 1738 512 4.16 / 583.60 5 71
6 13 404.44 20 14.89 922 275 4.43 / 583.88 5 74
7 8 -0.12 265 14.96 305 1209 5.64 / 585.09 6 131
Average= 6.88
(KJ/cycle)

Cycle 103 GMT 7/10/2024 5:46: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.28 39 14.96 458 267 0.27 / 574.24 6 23
2 7 2011.80 40 14.65 3130 1834 2.10 / 576.07 42 51
3 13 1823.44 20 14.64 2875 842 2.94 / 576.92 5 56
4 13 1329.32 20 14.67 2214 650 3.59 / 577.57 5 63
5 13 923.64 20 14.74 1657 488 4.08 / 578.05 5 73
6 13 193.76 20 14.97 605 181 4.26 / 578.24 5 68
7 8 0.00 266 14.97 304 1211 5.47 / 579.45 6 137
Average= 6.90
(KJ/cycle)

Cycle 102 GMT 27/ 9/2024 8:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.08 39 14.96 469 274 0.27 / 568.63 6 23
2 7 2006.72 40 14.64 3125 1830 2.10 / 570.46 23 50
3 13 1924.88 20 14.62 3019 883 2.99 / 571.34 5 56
4 13 1515.32 20 14.63 2470 723 3.71 / 572.07 5 59
5 13 975.96 20 14.73 1723 508 4.22 / 572.57 5 66
6 13 212.96 20 14.96 633 189 4.41 / 572.76 5 67
7 8 -0.20 265 14.97 305 1210 5.62 / 573.97 6 134
Average= 6.92
(KJ/cycle)

Cycle 101 GMT 17/ 9/2024 11: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.28 39 14.96 448 261 0.26 / 562.97 6 27
2 7 2012.72 40 14.64 3127 1831 2.09 / 564.80 27 50
3 13 1931.72 20 14.62 3026 885 2.98 / 565.69 5 54
4 13 1408.64 20 14.65 2328 682 3.66 / 566.37 5 63
5 13 985.00 20 14.72 1753 516 4.18 / 566.89 5 67
6 13 327.00 20 14.92 827 247 4.42 / 567.13 5 72
7 8 0.00 267 14.97 306 1223 5.65 / 568.36 6 142
Average= 6.93
(KJ/cycle)

Cycle 100 GMT 7/ 9/2024 14: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.60 39 14.96 448 261 0.26 / 557.45 6 22
2 7 2012.20 40 14.65 3138 1839 2.10 / 559.29 22 51
3 13 1920.24 20 14.63 3016 882 2.98 / 560.17 5 53
4 13 1389.28 20 14.66 2296 673 3.66 / 560.85 5 63
5 13 868.20 20 14.77 1565 462 4.12 / 561.31 5 67
6 13 221.52 20 14.96 659 197 4.32 / 561.51 5 69
7 8 -0.12 266 14.97 303 1207 5.52 / 562.71 6 130
Average= 6.95
(KJ/cycle)

Cycle 99 GMT 28/ 8/2024 17: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.32 39 14.95 466 272 0.27 / 551.77 6 24
2 7 2005.16 40 14.65 3121 1829 2.10 / 553.60 24 51
3 13 1917.40 20 14.63 3012 881 2.98 / 554.48 5 55
4 13 1498.04 20 14.64 2452 718 3.70 / 555.20 5 62
5 13 857.92 20 14.77 1577 466 4.17 / 555.66 5 70
6 13 420.56 20 14.88 964 287 4.45 / 555.95 5 74
7 8 0.00 268 14.97 309 1240 5.69 / 557.19 6 132
Average= 6.96
(KJ/cycle)

Cycle 98 GMT 18/ 8/2024 19:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.56 39 14.95 462 269 0.27 / 545.99 6 18
2 7 2010.64 40 14.64 3138 1838 2.11 / 547.83 18 51
3 13 1925.04 20 14.62 3016 882 2.99 / 548.71 5 54
4 13 1499.76 20 14.64 2458 720 3.71 / 549.43 5 62
5 13 958.08 20 14.74 1712 505 4.21 / 549.93 5 68
6 13 518.44 20 14.85 1106 328 4.54 / 550.26 5 77
7 13 13.44 20 15.02 336 101 4.64 / 550.36 5 64
8 8 -0.04 246 14.96 308 1133 5.78 / 551.50 6 131
Average= 6.98
(KJ/cycle)

Cycle 97 GMT 8/ 8/2024 23: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.72 39 14.95 457 266 0.27 / 540.36 6 20
2 7 2009.20 40 14.64 3131 1834 2.10 / 542.19 20 51
3 13 1933.04 20 14.63 3023 885 2.98 / 543.07 5 55
4 13 1398.68 20 14.66 2318 680 3.66 / 543.75 5 64
5 13 972.56 20 14.73 1729 509 4.17 / 544.26 5 72
6 13 321.04 20 14.92 816 243 4.42 / 544.51 5 73
7 8 0.04 267 14.97 304 1215 5.63 / 545.72 6 140
Average= 7.00
(KJ/cycle)

Cycle 96 GMT 30/ 7/2024 2: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.04 39 14.96 461 269 0.27 / 534.50 6 19
2 7 2015.36 40 14.65 3138 1839 2.11 / 536.34 19 50
3 13 1935.60 20 14.63 3029 886 2.99 / 537.23 5 53
4 13 1527.08 20 14.64 2482 727 3.72 / 537.95 5 60
5 13 1091.28 20 14.70 1893 557 4.28 / 538.51 5 66
6 13 507.00 20 14.85 1086 323 4.60 / 538.83 5 77
7 8 -0.12 270 14.96 311 1256 5.86 / 540.09 6 133
Average= 7.01
(KJ/cycle)

Cycle 95 GMT 20/ 7/2024 5:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.92 39 14.96 449 262 0.26 / 528.85 6 20
2 7 2015.40 40 14.65 3137 1838 2.10 / 530.69 20 52
3 13 1929.20 20 14.63 3021 884 2.98 / 531.57 5 56
4 13 1409.40 20 14.66 2340 686 3.67 / 532.26 5 62
5 13 880.16 20 14.76 1608 475 4.14 / 532.73 5 70
6 13 329.32 20 14.92 832 248 4.39 / 532.98 5 74
7 8 -0.08 267 14.96 314 1254 5.65 / 534.23 6 136
Average= 7.03
(KJ/cycle)

Cycle 94 GMT 10/ 7/2024 8:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.84 39 14.97 438 256 0.26 / 523.10 6 22
2 7 2006.12 40 14.66 3119 1829 2.08 / 524.93 22 53
3 13 1918.56 20 14.64 3003 879 2.96 / 525.81 5 57
4 13 1723.76 20 14.60 2735 799 3.76 / 526.61 5 60
5 13 967.24 20 14.74 1724 508 4.27 / 527.11 5 72
6 13 319.80 20 14.93 820 245 4.52 / 527.36 5 74
7 8 -0.08 268 14.97 306 1228 5.74 / 528.59 6 134
Average= 7.05
(KJ/cycle)

Cycle 93 GMT 30/ 6/2024 11:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 39 14.96 442 258 0.26 / 517.50 6 15
2 7 2010.28 40 14.65 3127 1832 2.09 / 519.33 15 52
3 13 1933.08 20 14.63 3023 885 2.97 / 520.22 5 54
4 13 1418.60 20 14.66 2335 685 3.66 / 520.90 5 64
5 13 995.44 20 14.73 1773 522 4.18 / 521.43 5 74
6 13 227.68 20 14.96 671 201 4.38 / 521.63 5 66
7 8 -0.12 268 14.98 303 1216 5.60 / 522.84 6 140
Average= 7.07
(KJ/cycle)

Cycle 92 GMT 20/ 6/2024 14:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.76 39 14.96 461 269 0.27 / 511.68 6 11
2 7 2011.12 40 14.65 3126 1832 2.10 / 513.52 11 52
3 13 1923.80 20 14.64 3010 881 2.98 / 514.40 5 56
4 13 1721.80 20 14.60 2754 804 3.79 / 515.20 5 56
5 13 934.52 20 14.75 1701 502 4.29 / 515.70 5 69
6 13 479.88 20 14.87 1049 312 4.60 / 516.01 5 72
7 8 0.04 270 14.97 304 1229 5.83 / 517.24 6 141
Average= 7.09
(KJ/cycle)

Cycle 91 GMT 10/ 6/2024 17:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.40 39 14.97 459 268 0.27 / 506.00 6 16
2 7 2013.72 40 14.66 3126 1833 2.10 / 507.83 16 50
3 13 1931.32 20 14.64 3011 882 2.98 / 508.71 5 55
4 13 1496.52 20 14.65 2456 720 3.70 / 509.43 5 60
5 13 948.00 20 14.74 1710 504 4.21 / 509.94 5 69
6 13 308.36 20 14.93 809 242 4.45 / 510.18 5 71
7 8 -0.08 270 14.97 306 1237 5.68 / 511.41 6 139
Average= 7.10
(KJ/cycle)

Cycle 90 GMT 31/ 5/2024 20:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.16 39 14.96 453 264 0.26 / 500.28 6 17
2 7 2018.68 40 14.65 3139 1839 2.10 / 502.12 17 49
3 13 1939.24 20 14.63 3026 885 2.99 / 503.00 5 55
4 13 1505.68 20 14.64 2454 719 3.71 / 503.72 5 62
5 13 963.44 20 14.73 1732 510 4.22 / 504.23 5 68
6 13 325.72 20 14.92 830 248 4.47 / 504.48 5 72
7 8 -0.04 270 14.97 310 1253 5.72 / 505.73 6 132
Average= 7.12
(KJ/cycle)

Cycle 89 GMT 21/ 5/2024 23:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.32 39 14.96 436 254 0.25 / 494.64 6 16
2 7 2012.00 40 14.66 3126 1833 2.09 / 496.48 16 52
3 13 1924.60 20 14.63 3014 882 2.97 / 497.36 5 57
4 13 1414.36 20 14.66 2330 683 3.65 / 498.04 5 66
5 13 903.84 20 14.75 1658 489 4.14 / 498.53 5 70
6 13 262.92 20 14.95 740 221 4.36 / 498.75 5 70
7 13 31.28 20 15.02 370 111 4.47 / 498.86 6 63
8 8 -0.04 250 14.97 307 1149 5.62 / 500.01 6 140
Average= 7.14
(KJ/cycle)

Cycle 88 GMT 12/ 5/2024 2:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.08 39 14.96 449 262 0.26 / 488.90 6 16
2 7 2012.64 41 14.65 3144 1888 2.15 / 490.78 16 51
3 13 1923.08 20 14.63 3018 883 3.03 / 491.67 5 54
4 13 1605.20 20 14.62 2598 760 3.79 / 492.43 5 60
5 13 862.64 20 14.77 1593 471 4.26 / 492.90 5 70
6 13 326.88 20 14.92 836 249 4.51 / 493.15 5 75
7 8 0.04 270 14.97 307 1241 5.75 / 494.39 6 141
Average= 7.17
(KJ/cycle)

Cycle 87 GMT 2/ 5/2024 5:10: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.16 39 14.96 444 259 0.26 / 483.11 6 13
2 7 2009.44 40 14.66 3125 1832 2.09 / 484.94 13 50
3 13 1919.40 20 14.64 2999 878 2.97 / 485.82 5 55
4 13 1501.04 20 14.65 2436 714 3.68 / 486.53 5 60
5 13 1048.44 20 14.72 1833 540 4.22 / 487.07 5 66
6 13 491.76 20 14.86 1070 318 4.54 / 487.39 5 75
7 13 14.16 20 15.02 344 103 4.64 / 487.49 6 60
8 8 -0.16 248 14.96 308 1143 5.79 / 488.63 6 130
Average= 7.19
(KJ/cycle)

Cycle 86 GMT 22/ 4/2024 8:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.24 39 14.96 441 257 0.26 / 477.17 6 14
2 7 2012.28 40 14.66 3137 1840 2.10 / 479.01 14 51
3 13 1943.12 20 14.64 3037 889 2.99 / 479.90 5 53
4 13 1848.60 20 14.58 2909 848 3.83 / 480.75 5 58
5 13 1043.56 20 14.72 1828 538 4.37 / 481.29 5 69
6 13 476.56 20 14.87 1050 312 4.68 / 481.60 5 75
7 13 27.28 20 15.02 359 108 4.79 / 481.71 6 64
8 8 -0.12 248 14.96 307 1139 5.93 / 482.85 6 133
Average= 7.21
(KJ/cycle)

Cycle 85 GMT 12/ 4/2024 11:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.00 39 14.96 453 264 0.26 / 471.40 6 13
2 7 2004.88 40 14.66 3126 1833 2.10 / 473.24 13 52
3 13 1922.00 20 14.63 3035 888 2.99 / 474.12 5 54
4 13 1502.84 20 14.64 2469 723 3.71 / 474.85 5 64
5 13 1050.24 20 14.71 1857 546 4.25 / 475.39 5 71
6 13 381.56 20 14.90 918 274 4.53 / 475.67 5 71
7 13 31.60 20 15.02 370 111 4.64 / 475.78 6 60
8 8 0.00 246 14.96 309 1137 5.78 / 476.92 6 135
Average= 7.23
(KJ/cycle)

Cycle 84 GMT 2/ 4/2024 14:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.20 39 14.97 444 259 0.26 / 465.53 6 15
2 7 2011.84 40 14.66 3126 1833 2.09 / 467.36 15 50
3 13 1919.84 20 14.64 3005 880 2.97 / 468.24 5 56
4 13 1588.20 20 14.63 2564 750 3.72 / 468.99 5 60
5 13 1039.68 20 14.72 1823 537 4.26 / 469.53 5 68
6 13 582.36 20 14.83 1205 357 4.62 / 469.88 5 78
7 13 42.76 20 15.01 388 116 4.73 / 470.00 5 66
8 8 -0.12 248 14.96 307 1139 5.87 / 471.14 6 133
Average= 7.25
(KJ/cycle)

Cycle 83 GMT 23/ 3/2024 17:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.12 39 14.96 458 267 0.27 / 459.92 6 12
2 7 2008.64 40 14.66 3120 1830 2.10 / 461.75 12 51
3 13 1923.80 20 14.64 3013 882 2.98 / 462.64 5 55
4 13 1510.24 20 14.65 2459 720 3.70 / 463.36 5 62
5 13 863.20 20 14.77 1579 466 4.17 / 463.82 5 71
6 13 242.44 20 14.96 695 208 4.37 / 464.03 5 69
7 13 29.52 20 15.02 362 109 4.48 / 464.14 6 65
8 8 -0.16 246 14.97 306 1127 5.61 / 465.27 6 134
Average= 7.27
(KJ/cycle)

Cycle 82 GMT 13/ 3/2024 20:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.16 39 14.96 447 261 0.26 / 454.18 6 13
2 7 2013.60 41 14.65 3132 1881 2.14 / 456.06 13 50
3 13 1929.96 20 14.64 3026 886 3.03 / 456.94 5 55
4 13 1628.56 20 14.61 2628 768 3.80 / 457.71 5 60
5 13 851.28 20 14.77 1575 465 4.26 / 458.18 5 70
6 13 206.32 20 14.97 643 193 4.45 / 458.37 5 69
7 13 47.48 20 15.01 403 121 4.57 / 458.49 5 67
8 8 -0.08 246 14.96 317 1167 5.74 / 459.66 6 130
Average= 7.30
(KJ/cycle)

Cycle 81 GMT 3/ 3/2024 23:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.28 39 14.95 440 257 0.26 / 448.50 6 19
2 7 2005.32 40 14.66 3126 1833 2.09 / 450.33 19 50
3 13 1918.12 20 14.65 3008 881 2.97 / 451.21 5 53
4 13 1513.48 20 14.64 2473 724 3.70 / 451.94 5 60
5 13 783.52 20 14.79 1483 439 4.13 / 452.38 5 72
6 13 457.80 20 14.87 1022 304 4.44 / 452.68 5 74
7 8 -0.04 265 14.96 312 1237 5.67 / 453.92 6 133
Average= 7.32
(KJ/cycle)

Cycle 80 GMT 23/ 2/2024 2:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.44 39 14.96 446 260 0.26 / 442.68 6 12
2 7 2006.88 40 14.66 3139 1841 2.10 / 444.52 12 51
3 13 1928.24 20 14.64 3037 889 2.99 / 445.41 5 55
4 13 1603.04 20 14.62 2617 765 3.76 / 446.18 5 61
5 13 954.68 20 14.73 1729 509 4.26 / 446.69 5 71
6 13 405.36 20 14.89 949 283 4.55 / 446.97 5 77
7 13 41.04 20 15.01 389 117 4.66 / 447.09 5 64
8 8 -0.20 249 14.95 310 1154 5.82 / 448.24 6 139
Average= 7.35
(KJ/cycle)

Cycle 79 GMT 13/ 2/2024 5:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.56 39 14.96 449 262 0.26 / 436.97 6 15
2 7 2004.44 41 14.66 3137 1886 2.15 / 438.86 15 51
3 13 1908.60 20 14.64 3005 880 3.03 / 439.74 5 54
4 13 1401.36 20 14.67 2322 681 3.71 / 440.42 5 64
5 13 969.52 20 14.73 1733 511 4.22 / 440.93 5 71
6 13 297.68 20 14.93 780 233 4.45 / 441.16 5 74
7 13 17.44 20 15.02 349 105 4.56 / 441.27 6 60
8 8 -0.08 249 14.96 310 1155 5.71 / 442.42 6 148
Average= 7.37
(KJ/cycle)

Cycle 78 GMT 3/ 2/2024 8:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.64 39 14.96 455 265 0.27 / 431.34 6 12
2 7 2004.72 40 14.67 3127 1835 2.10 / 433.17 12 52
3 13 1913.96 20 14.65 3017 884 2.98 / 434.05 5 55
4 13 1491.20 20 14.65 2450 718 3.70 / 434.77 5 63
5 13 1037.72 20 14.71 1826 537 4.24 / 435.31 5 69
6 13 187.68 20 14.98 610 183 4.42 / 435.49 5 69
7 13 16.60 20 15.02 340 102 4.52 / 435.59 6 65
8 8 -0.16 248 14.97 301 1117 5.64 / 436.71 6 144
Average= 7.40
(KJ/cycle)

Cycle 77 GMT 24/ 1/2024 11:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.04 39 14.96 450 263 0.26 / 425.46 6 12
2 7 2005.32 40 14.67 3121 1831 2.09 / 427.29 12 53
3 13 1926.16 20 14.64 3020 884 2.98 / 428.18 5 54
4 13 1611.80 20 14.63 2578 754 3.73 / 428.93 5 61
5 13 1158.88 20 14.68 2002 588 4.32 / 429.52 5 71
6 13 359.56 20 14.91 882 263 4.58 / 429.78 5 79
7 13 59.84 20 15.00 418 125 4.71 / 429.91 5 62
8 8 -0.04 248 14.96 313 1161 5.87 / 431.07 6 143
Average= 7.43
(KJ/cycle)

Cycle 76 GMT 14/ 1/2024 14:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.08 39 14.97 447 261 0.26 / 419.87 6 12
2 7 2007.96 40 14.67 3126 1834 2.10 / 421.71 12 50
3 13 1925.96 20 14.65 2996 878 2.97 / 422.58 5 54
4 13 1502.96 20 14.65 2454 719 3.69 / 423.30 5 62
5 13 867.64 20 14.76 1601 473 4.16 / 423.78 5 73
6 13 222.44 20 14.96 667 200 4.36 / 423.98 5 71
7 8 -0.04 270 14.97 303 1225 5.59 / 425.20 6 142
Average= 7.46
(KJ/cycle)

Cycle 75 GMT 4/ 1/2024 17:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.20 39 14.95 443 258 0.26 / 414.27 6 18
2 7 2007.76 40 14.67 3121 1831 2.09 / 416.10 42 53
3 13 1920.36 20 14.65 2998 878 2.97 / 416.98 5 56
4 13 1612.76 20 14.64 2585 757 3.72 / 417.73 5 59
5 13 852.92 20 14.77 1556 460 4.18 / 418.19 5 69
6 13 214.52 20 14.97 642 192 4.38 / 418.38 5 72
7 8 -0.08 267 14.97 307 1227 5.60 / 419.61 6 135
Average= 7.49
(KJ/cycle)

Cycle 74 GMT 25/12/2023 20:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.60 39 14.95 462 269 0.27 / 408.60 6 15
2 7 2008.20 40 14.67 3135 1840 2.11 / 410.44 15 53
3 13 1921.20 20 14.65 3030 888 3.00 / 411.33 5 55
4 13 1492.80 20 14.65 2450 718 3.71 / 412.05 5 63
5 13 953.84 20 14.74 1716 506 4.22 / 412.56 5 71
6 13 283.20 20 14.93 767 229 4.45 / 412.79 5 73
7 8 -0.24 267 14.96 306 1222 5.67 / 414.01 6 135
Average= 7.53
(KJ/cycle)

Cycle 73 GMT 15/12/2023 23:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.28 39 14.95 444 259 0.26 / 402.84 6 14
2 7 2006.32 40 14.67 3126 1834 2.09 / 404.67 14 52
3 13 1924.72 20 14.65 3014 883 2.98 / 405.55 5 55
4 13 1499.92 20 14.65 2469 723 3.70 / 406.28 5 61
5 13 1066.32 20 14.71 1862 548 4.25 / 406.82 5 65
6 13 386.40 20 14.89 912 272 4.52 / 407.10 5 73
7 8 -0.08 270 14.96 307 1240 5.76 / 408.34 6 147
Average= 7.56
(KJ/cycle)

Cycle 72 GMT 6/12/2023 2:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.36 39 14.95 442 258 0.26 / 397.14 6 18
2 7 2004.08 40 14.68 3122 1833 2.09 / 398.98 18 53
3 13 1923.08 20 14.66 3015 884 2.97 / 399.86 5 53
4 13 1488.44 20 14.66 2461 722 3.70 / 400.58 5 61
5 13 955.32 20 14.74 1714 505 4.20 / 401.09 5 72
6 13 288.64 20 14.93 777 232 4.43 / 401.32 5 77
7 8 0.00 265 14.96 317 1257 5.69 / 402.58 6 131
Average= 7.60
(KJ/cycle)

Cycle 71 GMT 26/11/2023 5:41: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.24 39 14.95 456 266 0.27 / 391.42 6 20
2 7 2004.56 40 14.68 3123 1834 2.10 / 393.25 20 53
3 13 1915.20 20 14.66 3005 881 2.98 / 394.13 5 58
4 13 1510.84 20 14.65 2466 723 3.70 / 394.85 5 61
5 13 971.48 20 14.73 1738 512 4.22 / 395.37 5 73
6 13 414.80 20 14.88 963 287 4.50 / 395.65 5 80
7 8 -0.04 267 14.96 309 1234 5.74 / 396.89 6 138
Average= 7.63
(KJ/cycle)

Cycle 70 GMT 16/11/2023 8:47: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.92 38 14.95 469 266 0.27 / 385.81 6 19
2 7 2007.24 40 14.67 3130 1837 2.10 / 387.64 19 52
3 13 1923.04 20 14.65 3019 885 2.99 / 388.53 5 57
4 13 1382.00 20 14.67 2309 677 3.67 / 389.21 5 66
5 13 866.60 20 14.76 1601 473 4.14 / 389.68 5 72
6 13 313.44 20 14.92 811 242 4.38 / 389.92 5 72
7 8 -0.04 265 14.96 310 1229 5.61 / 391.15 6 137
Average= 7.67
(KJ/cycle)

Cycle 69 GMT 6/11/2023 11:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.68 38 14.95 460 261 0.26 / 379.86 6 21
2 7 2007.28 40 14.68 3138 1843 2.10 / 381.70 21 52
3 13 1924.04 20 14.66 3029 888 2.99 / 382.59 5 55
4 13 1610.20 20 14.64 2613 765 3.76 / 383.35 5 61
5 13 1264.92 20 14.66 2140 627 4.38 / 383.98 5 69
6 13 465.80 20 14.87 1037 308 4.69 / 384.29 5 77
7 8 0.04 267 14.97 313 1251 5.94 / 385.54 6 129
Average= 7.71
(KJ/cycle)

Cycle 68 GMT 27/10/2023 15: 6: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.00 38 14.95 463 263 0.26 / 374.18 6 19
2 7 2004.80 41 14.68 3132 1885 2.15 / 376.06 19 51
3 13 1916.88 20 14.66 3018 885 3.03 / 376.95 5 55
4 13 1399.20 20 14.68 2321 681 3.71 / 377.63 5 64
5 13 966.20 20 14.73 1736 511 4.23 / 378.14 5 71
6 13 298.48 20 14.92 795 237 4.46 / 378.38 5 78
7 8 -0.08 263 14.96 310 1220 5.68 / 379.60 6 129
Average= 7.75
(KJ/cycle)

Cycle 67 GMT 17/10/2023 18: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.56 38 14.96 459 261 0.26 / 368.47 6 20
2 7 2010.36 40 14.69 3137 1843 2.10 / 370.31 20 52
3 13 1924.64 20 14.67 3025 888 2.99 / 371.20 5 56
4 13 1498.44 20 14.67 2459 721 3.71 / 371.92 5 63
5 13 953.04 20 14.74 1707 503 4.22 / 372.43 5 73
6 13 318.52 20 14.92 821 245 4.46 / 372.67 5 72
7 8 -0.08 267 14.97 311 1243 5.70 / 373.91 6 129
Average= 7.79
(KJ/cycle)

Cycle 66 GMT 7/10/2023 20:58: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.36 38 14.96 452 257 0.26 / 362.83 6 18
2 7 2010.92 40 14.68 3142 1845 2.10 / 364.67 18 51
3 13 1915.88 20 14.67 3019 886 2.99 / 365.56 5 55
4 13 1495.64 20 14.66 2453 719 3.71 / 366.28 5 64
5 13 1071.16 20 14.70 1891 556 4.26 / 366.84 5 69
6 13 168.68 20 14.98 590 177 4.44 / 367.01 5 73
7 8 -0.04 263 14.98 304 1198 5.64 / 368.21 6 129
Average= 7.83
(KJ/cycle)

Cycle 65 GMT 27/ 9/2023 23:58: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.16 38 14.96 463 263 0.26 / 357.22 6 21
2 7 2006.32 40 14.70 3124 1837 2.10 / 359.06 21 52
3 13 1920.20 20 14.68 3022 887 2.99 / 359.95 5 55
4 13 1387.88 20 14.69 2310 679 3.67 / 360.63 5 65
5 13 855.28 20 14.77 1597 472 4.14 / 361.10 5 73
6 13 306.44 20 14.93 802 239 4.38 / 361.34 5 73
7 8 -0.04 267 14.97 309 1235 5.61 / 362.57 6 144
Average= 7.88
(KJ/cycle)

Cycle 64 GMT 18/ 9/2023 2:55: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.36 38 14.96 463 263 0.26 / 351.57 6 17
2 7 2005.72 40 14.69 3129 1839 2.10 / 353.41 45 52
3 13 1921.04 20 14.67 3014 884 2.99 / 354.29 5 56
4 13 1314.24 20 14.71 2205 649 3.63 / 354.94 5 63
5 13 984.16 20 14.74 1768 521 4.16 / 355.46 5 73
6 13 308.36 20 14.93 809 242 4.40 / 355.71 5 76
7 13 37.28 20 15.02 381 114 4.51 / 355.82 6 64
8 8 -0.08 244 14.97 312 1140 5.65 / 356.96 6 134
Average= 7.93
(KJ/cycle)

Cycle 63 GMT 8/ 9/2023 5:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.84 38 14.97 462 263 0.26 / 345.92 6 16
2 7 2008.20 41 14.69 3135 1888 2.15 / 347.80 16 54
3 13 1928.60 20 14.67 3035 890 3.04 / 348.69 5 57
4 13 1391.88 20 14.70 2299 676 3.72 / 349.37 5 61
5 13 872.96 20 14.78 1601 473 4.19 / 349.84 5 74
6 13 326.24 20 14.93 834 249 4.44 / 350.09 5 78
7 8 -0.08 261 14.98 311 1216 5.66 / 351.31 6 132
Average= 7.98
(KJ/cycle)

Cycle 62 GMT 29/ 8/2023 8:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.96 38 14.98 452 257 0.26 / 340.20 6 20
2 7 2016.92 40 14.70 3149 1852 2.11 / 342.05 20 51
3 13 1930.84 20 14.68 3038 892 3.00 / 342.94 5 55
4 13 1494.04 20 14.68 2452 720 3.72 / 343.66 5 65
5 13 852.64 20 14.79 1590 470 4.19 / 344.13 5 72
6 13 422.20 20 14.90 982 293 4.48 / 344.42 5 80
7 8 -0.04 265 14.98 310 1231 5.71 / 345.65 6 136
Average= 8.04
(KJ/cycle)

Cycle 61 GMT 19/ 8/2023 11:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.40 38 14.98 463 264 0.26 / 334.57 6 23
2 7 2004.48 41 14.70 3125 1883 2.15 / 336.46 23 53
3 13 1913.04 20 14.68 3012 884 3.03 / 337.34 5 56
4 13 1405.64 20 14.70 2341 688 3.72 / 338.03 5 62
5 13 884.60 20 14.78 1623 480 4.20 / 338.51 5 70
6 13 235.16 20 14.97 696 208 4.41 / 338.72 5 74
7 8 -0.04 266 14.99 306 1220 5.63 / 339.94 6 140
Average= 8.09
(KJ/cycle)

Cycle 60 GMT 9/ 8/2023 14:37:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.32 38 14.97 466 265 0.27 / 328.87 6 24
2 7 2003.88 40 14.71 3117 1834 2.10 / 330.70 24 52
3 13 1815.08 20 14.70 2865 842 2.94 / 331.55 5 57
4 13 1607.36 20 14.66 2617 767 3.71 / 332.31 5 62
5 13 1057.84 20 14.74 1859 548 4.26 / 332.86 5 65
6 13 280.72 20 14.96 770 230 4.49 / 333.09 5 76
7 8 -0.12 263 14.99 309 1218 5.71 / 334.31 6 135
Average= 8.15
(KJ/cycle)

Cycle 59 GMT 30/ 7/2023 17:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.36 38 14.99 452 257 0.26 / 323.25 6 15
2 7 2007.72 40 14.70 3136 1844 2.10 / 325.10 15 54
3 13 1921.44 20 14.69 3021 888 2.99 / 325.99 5 55
4 13 1368.92 20 14.72 2275 670 3.66 / 326.65 5 65
5 13 939.64 20 14.78 1676 495 4.15 / 327.15 5 73
6 13 274.20 20 14.97 751 225 4.38 / 327.38 5 76
7 8 0.08 263 14.99 312 1230 5.61 / 328.61 6 148
Average= 8.22
(KJ/cycle)

Cycle 58 GMT 20/ 7/2023 20:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.08 38 14.99 461 263 0.26 / 317.63 6 19
2 7 2005.08 40 14.71 3139 1847 2.11 / 319.48 19 51
3 13 1909.76 20 14.70 3008 884 2.99 / 320.37 5 55
4 13 1390.28 20 14.72 2298 677 3.67 / 321.04 5 62
5 13 980.40 20 14.76 1755 518 4.19 / 321.56 5 69
6 13 232.68 20 14.99 694 208 4.40 / 321.77 5 74
7 8 0.00 265 15.00 309 1228 5.62 / 323.00 6 137
Average= 8.28
(KJ/cycle)

Cycle 57 GMT 10/ 7/2023 23:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.72 38 15.00 437 249 0.25 / 311.79 6 18
2 7 2016.48 41 14.70 3151 1899 2.15 / 313.69 18 53
3 13 1924.28 20 14.69 3031 891 3.04 / 314.58 5 56
4 13 1494.96 20 14.70 2440 717 3.76 / 315.30 5 63
5 13 951.88 20 14.79 1698 502 4.26 / 315.80 5 70
6 13 506.08 20 14.89 1098 327 4.59 / 316.13 5 78
7 8 0.00 265 15.00 312 1240 5.83 / 317.37 6 144
Average= 8.35
(KJ/cycle)

Cycle 56 GMT 1/ 7/2023 2:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.16 38 15.00 455 259 0.26 / 306.16 6 16
2 7 2007.40 41 14.71 3132 1889 2.15 / 308.05 16 51
3 13 1925.44 20 14.69 3019 887 3.04 / 308.93 5 56
4 13 1501.52 20 14.70 2457 722 3.76 / 309.66 5 62
5 13 840.92 20 14.82 1558 462 4.22 / 310.12 5 73
6 13 200.12 20 15.01 640 192 4.41 / 310.31 5 73
7 8 -0.04 263 15.01 313 1236 5.65 / 311.55 6 132
Average= 8.42
(KJ/cycle)

Cycle 55 GMT 21/ 6/2023 5:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.52 38 15.01 456 260 0.26 / 300.58 6 14
2 7 2007.12 40 14.71 3142 1849 2.11 / 302.43 59 54
3 13 1924.04 20 14.69 3038 893 3.00 / 303.32 5 57
4 13 1505.20 20 14.70 2466 725 3.73 / 304.04 5 62
5 13 751.16 20 14.85 1442 428 4.15 / 304.47 5 73
6 13 129.44 20 15.04 535 161 4.32 / 304.63 5 67
7 8 -0.12 266 15.02 317 1267 5.58 / 305.90 6 140
Average= 8.50
(KJ/cycle)

Cycle 54 GMT 11/ 6/2023 8:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.32 38 15.01 449 256 0.26 / 295.02 6 16
2 7 2008.40 40 14.72 3133 1845 2.10 / 296.86 16 52
3 13 1925.92 20 14.69 3023 888 2.99 / 297.75 5 54
4 13 1304.84 20 14.74 2188 645 3.63 / 298.40 5 66
5 13 878.40 20 14.82 1607 476 4.11 / 298.87 5 70
6 13 125.44 20 15.04 526 158 4.27 / 299.03 5 67
7 13 38.04 20 15.06 382 115 4.38 / 299.15 6 59
8 8 -0.12 249 15.01 313 1170 5.55 / 300.32 6 138
Average= 8.58
(KJ/cycle)

Cycle 53 GMT 1/ 6/2023 11: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.60 38 15.01 442 252 0.25 / 289.45 6 16
2 7 2009.76 40 14.71 3134 1844 2.10 / 291.30 16 52
3 13 1917.32 20 14.70 3010 885 2.98 / 292.18 5 56
4 13 1402.32 20 14.73 2319 683 3.66 / 292.86 5 67
5 13 863.80 20 14.82 1593 472 4.14 / 293.34 5 72
6 13 216.00 20 15.01 657 197 4.33 / 293.53 5 70
7 8 0.08 265 15.02 309 1230 5.56 / 294.76 6 132
Average= 8.67
(KJ/cycle)

Cycle 52 GMT 22/ 5/2023 13:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.96 38 15.03 445 254 0.25 / 283.78 6 13
2 7 2010.84 40 14.72 3135 1846 2.10 / 285.62 13 52
3 13 1912.88 20 14.71 3003 883 2.98 / 286.51 5 56
4 13 1391.20 20 14.74 2297 677 3.66 / 287.19 5 63
5 13 859.04 20 14.83 1588 471 4.13 / 287.66 5 71
6 13 414.60 20 14.94 963 288 4.42 / 287.94 5 77
7 8 -0.08 267 15.02 313 1255 5.67 / 289.20 6 138
Average= 8.76
(KJ/cycle)

Cycle 51 GMT 12/ 5/2023 16:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.36 38 15.02 443 253 0.25 / 278.21 6 15
2 7 2006.00 41 14.72 3124 1885 2.14 / 280.09 15 51
3 13 1919.72 20 14.70 3003 883 3.02 / 280.97 5 55
4 13 1385.40 20 14.75 2286 674 3.70 / 281.65 5 62
5 13 851.24 20 14.83 1588 471 4.17 / 282.12 5 74
6 13 204.60 20 15.03 648 195 4.36 / 282.31 5 71
7 8 -0.04 265 15.03 304 1211 5.57 / 283.52 6 131
Average= 8.86
(KJ/cycle)

Cycle 50 GMT 2/ 5/2023 19:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.48 38 15.03 436 249 0.25 / 272.42 6 13
2 7 2004.16 40 14.73 3127 1842 2.09 / 274.26 13 51
3 13 1918.36 20 14.71 3025 890 2.98 / 275.15 5 55
4 13 1490.48 20 14.72 2465 726 3.71 / 275.88 5 61
5 13 1137.20 20 14.76 1977 584 4.29 / 276.46 5 68
6 13 249.36 20 15.02 721 217 4.51 / 276.68 5 75
7 13 16.04 20 15.09 349 105 4.61 / 276.79 6 60
8 8 -0.16 248 15.03 313 1167 5.78 / 277.95 6 135
Average= 8.97
(KJ/cycle)

Cycle 49 GMT 22/ 4/2023 22:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.48 38 15.03 454 259 0.26 / 266.79 6 14
2 7 2004.96 40 14.72 3129 1842 2.10 / 268.64 14 53
3 13 1913.80 20 14.71 3015 887 2.99 / 269.52 5 56
4 13 1395.84 20 14.74 2318 683 3.67 / 270.21 5 66
5 13 972.32 20 14.81 1747 517 4.19 / 270.72 5 70
6 13 191.08 20 15.04 630 190 4.38 / 270.91 5 72
7 8 0.04 267 15.03 314 1260 5.64 / 272.17 6 143
Average= 9.07
(KJ/cycle)

Cycle 48 GMT 13/ 4/2023 1:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.96 38 15.02 455 260 0.26 / 261.00 6 15
2 7 2007.88 40 14.72 3142 1850 2.11 / 262.85 15 53
3 13 1924.52 20 14.71 3028 891 3.00 / 263.74 5 56
4 13 1524.24 20 14.72 2487 732 3.73 / 264.47 5 62
5 13 1069.24 20 14.78 1869 552 4.29 / 265.02 5 70
6 13 279.60 20 15.01 774 232 4.52 / 265.26 5 75
7 8 -0.04 268 15.04 317 1278 5.80 / 266.53 6 138
Average= 9.19
(KJ/cycle)

Cycle 47 GMT 3/ 4/2023 4:41: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.96 38 15.03 441 252 0.25 / 255.04 6 13
2 7 2006.36 40 14.73 3126 1842 2.09 / 256.88 13 52
3 13 1921.20 20 14.70 3045 895 2.99 / 257.77 5 56
4 13 1611.40 20 14.70 2631 774 3.76 / 258.55 5 62
5 13 1144.00 20 14.76 2002 591 4.35 / 259.14 5 70
6 13 441.76 20 14.95 1015 303 4.66 / 259.44 5 77
7 8 -0.12 267 15.04 323 1297 5.95 / 260.74 6 134
Average= 9.31
(KJ/cycle)

Cycle 46 GMT 24/ 3/2023 7:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.04 38 15.04 453 259 0.26 / 249.14 6 13
2 7 2007.48 40 14.74 3132 1847 2.11 / 250.99 13 51
3 13 1923.84 20 14.72 3013 887 2.99 / 251.87 5 56
4 13 1726.12 20 14.69 2755 809 3.80 / 252.68 5 60
5 13 837.68 20 14.86 1573 467 4.27 / 253.15 5 72
6 13 519.72 20 14.93 1128 337 4.61 / 253.49 5 79
7 13 29.76 20 15.09 378 114 4.72 / 253.60 6 66
8 8 -0.08 248 15.04 317 1182 5.90 / 254.78 6 131
Average= 9.44
(KJ/cycle)

Cycle 45 GMT 14/ 3/2023 10:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.04 38 15.05 452 258 0.26 / 243.24 6 12
2 7 2004.72 40 14.74 3128 1844 2.10 / 245.09 12 51
3 13 1912.24 20 14.72 3018 888 2.99 / 245.97 5 57
4 13 1601.76 20 14.71 2614 769 3.76 / 246.74 5 61
5 13 943.16 20 14.83 1719 510 4.27 / 247.25 5 72
6 13 495.96 20 14.95 1089 326 4.60 / 247.58 5 76
7 8 -0.16 270 15.04 321 1304 5.90 / 248.88 6 141
Average= 9.57
(KJ/cycle)

Cycle 44 GMT 4/ 3/2023 13:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.24 38 15.05 436 249 0.25 / 237.51 6 13
2 7 2017.16 40 14.73 3148 1855 2.10 / 239.36 39 51
3 13 1936.84 20 14.72 3031 892 3.00 / 240.25 5 55
4 13 1505.20 20 14.74 2448 722 3.72 / 240.98 5 63
5 13 968.52 20 14.83 1730 513 4.23 / 241.49 5 72
6 13 301.12 20 15.02 783 235 4.47 / 241.72 5 77
7 8 -0.12 268 15.06 312 1259 5.73 / 242.98 6 145
Average= 9.72
(KJ/cycle)

Cycle 43 GMT 22/ 2/2023 16:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.96 38 15.05 468 268 0.27 / 231.82 6 13
2 7 2011.72 40 14.74 3131 1846 2.11 / 233.66 13 51
3 13 1929.12 20 14.72 3025 891 3.00 / 234.55 5 55
4 13 1396.92 20 14.77 2312 683 3.69 / 235.24 5 65
5 13 978.08 20 14.83 1748 518 4.21 / 235.76 5 70
6 13 300.40 20 15.02 809 243 4.45 / 236.00 5 76
7 8 -0.08 267 15.06 313 1259 5.71 / 237.26 6 136
Average= 9.89
(KJ/cycle)

Cycle 42 GMT 12/ 2/2023 19:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.92 38 15.06 455 260 0.26 / 226.01 6 13
2 7 2007.60 40 14.75 3132 1848 2.11 / 227.86 13 52
3 13 1910.68 20 14.73 3008 886 2.99 / 228.75 5 55
4 13 1489.96 20 14.75 2449 722 3.72 / 229.47 5 64
5 13 937.28 20 14.85 1698 504 4.22 / 229.98 5 71
6 13 389.48 20 15.00 933 280 4.50 / 230.26 5 76
7 13 30.16 20 15.11 374 113 4.61 / 230.37 6 65
8 8 -0.12 246 15.06 319 1182 5.80 / 231.55 6 133
Average= 10.07
(KJ/cycle)

Cycle 41 GMT 2/ 2/2023 22:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.60 38 15.06 441 252 0.25 / 220.32 6 14
2 7 2006.20 40 14.75 3124 1843 2.10 / 222.17 14 53
3 13 1919.68 20 14.73 3006 886 2.98 / 223.05 5 54
4 13 1494.24 20 14.75 2440 720 3.70 / 223.77 5 64
5 13 966.76 20 14.84 1737 516 4.22 / 224.29 5 70
6 13 205.00 20 15.07 655 197 4.41 / 224.48 5 74
7 8 -0.08 265 15.06 318 1269 5.68 / 225.75 6 129
Average= 10.26
(KJ/cycle)

Cycle 40 GMT 24/ 1/2023 1:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.76 38 15.06 469 268 0.27 / 214.47 6 15
2 7 2011.56 40 14.74 3138 1850 2.12 / 216.32 15 50
3 13 1924.20 20 14.72 3028 891 3.01 / 217.21 5 56
4 13 1728.04 20 14.70 2758 811 3.82 / 218.02 5 60
5 13 1127.56 20 14.80 1963 581 4.40 / 218.61 5 68
6 13 121.04 20 15.10 517 156 4.56 / 218.76 5 68
7 13 25.44 20 15.12 370 112 4.67 / 218.87 6 63
8 8 0.08 246 15.07 323 1197 5.87 / 220.07 6 132
Average= 10.48
(KJ/cycle)

Cycle 39 GMT 14/ 1/2023 4:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.08 37 15.07 450 251 0.25 / 208.80 6 16
2 7 2007.80 40 14.75 3121 1841 2.09 / 210.64 16 51
3 13 1922.44 20 14.73 3014 888 2.98 / 211.53 5 55
4 13 1319.84 20 14.80 2211 654 3.63 / 212.18 5 68
5 13 912.68 20 14.87 1655 492 4.13 / 212.68 5 72
6 13 261.64 20 15.05 736 222 4.35 / 212.90 5 75
7 13 28.44 20 15.12 376 114 4.46 / 213.01 6 64
8 8 -0.08 246 15.06 322 1193 5.66 / 214.20 6 136
Average= 10.71
(KJ/cycle)

Cycle 38 GMT 4/ 1/2023 7:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.20 37 15.07 438 244 0.24 / 203.17 6 16
2 7 2005.04 41 14.75 3127 1891 2.14 / 205.07 16 53
3 13 1911.12 20 14.73 3013 888 3.02 / 205.95 5 56
4 13 1372.72 20 14.79 2301 681 3.70 / 206.63 5 64
5 13 839.48 20 14.89 1559 464 4.17 / 207.10 5 71
6 13 189.56 20 15.08 629 190 4.36 / 207.29 5 73
7 8 -0.12 263 15.08 318 1261 5.62 / 208.55 6 131
Average= 10.98
(KJ/cycle)

Cycle 37 GMT 25/12/2022 10:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.68 38 15.07 439 251 0.25 / 197.50 6 18
2 7 2005.56 40 14.75 3126 1844 2.10 / 199.35 18 52
3 13 1915.36 20 14.74 3012 888 2.98 / 200.23 5 56
4 13 1480.64 20 14.77 2435 719 3.70 / 200.95 5 64
5 13 828.16 20 14.90 1567 467 4.17 / 201.42 5 74
6 13 376.20 20 15.02 920 276 4.45 / 201.70 5 79
7 8 0.00 263 15.08 311 1233 5.68 / 202.93 6 131
Average= 11.27
(KJ/cycle)

Cycle 36 GMT 15/12/2022 13:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.92 38 15.08 450 258 0.26 / 191.67 6 18
2 7 2005.20 40 14.75 3142 1854 2.11 / 193.52 18 53
3 13 1915.68 20 14.74 3016 889 3.00 / 194.41 5 56
4 13 1705.60 20 14.72 2733 805 3.81 / 195.22 5 61
5 13 904.12 20 14.88 1658 493 4.30 / 195.71 5 71
6 13 346.88 20 15.03 874 263 4.56 / 195.97 5 78
7 8 0.00 265 15.09 319 1276 5.84 / 197.25 6 135
Average= 11.60
(KJ/cycle)

Cycle 35 GMT 5/12/2022 16:34:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.56 38 15.08 442 253 0.25 / 186.08 6 19
2 7 2012.08 40 14.75 3149 1858 2.11 / 187.94 19 52
3 13 1934.12 20 14.74 3048 899 3.01 / 188.84 5 55
4 13 1509.96 20 14.76 2498 737 3.75 / 189.57 5 63
5 13 761.76 20 14.92 1477 441 4.19 / 190.01 5 75
6 13 123.04 20 15.12 525 159 4.35 / 190.17 5 67
7 8 0.04 265 15.10 310 1240 5.59 / 191.41 6 135
Average= 11.96
(KJ/cycle)

Cycle 34 GMT 25/11/2022 19:30:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.84 38 15.08 464 266 0.27 / 180.39 6 19
2 7 2007.08 41 14.76 3130 1894 2.16 / 182.29 19 53
3 13 1915.60 20 14.75 3012 889 3.05 / 183.18 5 55
4 13 1467.56 20 14.78 2408 712 3.76 / 183.89 5 64
5 13 922.36 20 14.88 1681 500 4.26 / 184.39 5 73
6 13 177.92 20 15.10 609 184 4.44 / 184.57 5 72
7 8 -0.12 263 15.09 316 1254 5.70 / 185.83 6 130
Average= 12.39
(KJ/cycle)

Cycle 33 GMT 15/11/2022 22:30:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.80 38 15.08 464 266 0.27 / 174.77 6 21
2 7 2012.00 40 14.76 3145 1857 2.12 / 176.63 42 52
3 13 1920.28 20 14.74 3026 892 3.01 / 177.52 5 55
4 13 1515.60 20 14.77 2469 729 3.74 / 178.25 5 65
5 13 753.40 20 14.93 1450 433 4.18 / 178.68 5 74
6 13 111.36 20 15.13 509 154 4.33 / 178.84 5 67
7 8 -0.16 266 15.10 321 1289 5.62 / 180.13 6 137
Average= 12.87
(KJ/cycle)

Cycle 32 GMT 6/11/2022 1:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.16 38 15.08 467 268 0.27 / 169.03 6 21
2 7 2004.72 40 14.76 3134 1850 2.12 / 170.88 21 53
3 13 1910.40 20 14.76 3005 887 3.00 / 171.77 5 56
4 13 1484.76 20 14.78 2455 726 3.73 / 172.49 5 64
5 13 918.48 20 14.89 1688 503 4.23 / 173.00 5 73
6 13 240.32 20 15.09 710 214 4.45 / 173.21 5 75
7 8 0.04 265 15.09 324 1296 5.74 / 174.51 6 134
Average= 13.42
(KJ/cycle)

Cycle 31 GMT 27/10/2022 4:34:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.32 38 15.09 457 262 0.26 / 163.47 6 20
2 7 2007.04 40 14.76 3133 1850 2.11 / 165.32 20 51
3 13 1924.72 20 14.75 3043 898 3.01 / 166.22 5 56
4 13 1315.72 20 14.82 2222 659 3.67 / 166.88 5 66
5 13 789.12 20 14.92 1509 450 4.12 / 167.33 5 77
6 13 149.56 20 15.11 572 173 4.29 / 167.50 5 71
7 8 -0.16 261 15.10 321 1265 5.56 / 168.76 6 131
Average= 14.06
(KJ/cycle)

Cycle 30 GMT 17/10/2022 7:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.36 38 15.09 468 268 0.27 / 157.92 6 20
2 7 2012.56 40 14.77 3137 1853 2.12 / 159.77 20 52
3 13 1818.08 20 14.77 2892 854 2.98 / 160.62 5 58
4 13 1405.44 20 14.81 2344 694 3.67 / 161.32 5 67
5 13 765.36 20 14.94 1476 441 4.11 / 161.76 5 74
6 13 129.16 20 15.13 537 162 4.27 / 161.92 5 70
7 8 0.00 263 15.10 324 1287 5.56 / 163.21 6 132
Average= 14.84
(KJ/cycle)

Cycle 29 GMT 7/10/2022 10: 6:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.68 38 15.10 459 263 0.26 / 152.15 6 19
2 7 2006.24 40 14.77 3137 1853 2.12 / 154.01 19 51
3 13 1916.16 20 14.77 3005 888 3.00 / 154.89 5 56
4 13 1490.40 20 14.80 2438 722 3.73 / 155.62 5 64
5 13 1035.96 20 14.87 1832 545 4.27 / 156.16 5 71
6 13 158.48 20 15.13 580 176 4.45 / 156.34 5 73
7 8 0.00 267 15.11 325 1311 5.76 / 157.65 6 136
Average= 15.76
(KJ/cycle)

Cycle 28 GMT 27/ 9/2022 13: 7:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.12 38 15.10 468 269 0.27 / 146.52 6 19
2 7 2005.32 40 14.78 3129 1850 2.12 / 148.37 19 50
3 13 1915.76 20 14.77 3012 890 3.01 / 149.26 5 57
4 13 1394.80 20 14.82 2303 683 3.69 / 149.94 5 66
5 13 775.80 20 14.95 1476 441 4.13 / 150.39 5 74
6 13 240.32 20 15.10 709 214 4.35 / 150.60 5 75
7 8 -0.20 265 15.11 322 1289 5.64 / 151.89 6 134
Average= 16.88
(KJ/cycle)

Cycle 27 GMT 17/ 9/2022 15:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.00 38 15.10 468 269 0.27 / 140.68 6 20
2 7 2006.16 40 14.78 3141 1857 2.13 / 142.54 20 52
3 13 1921.24 20 14.77 3024 893 3.02 / 143.43 5 58
4 13 1718.44 20 14.75 2755 813 3.83 / 144.25 5 60
5 13 931.52 20 14.90 1701 507 4.34 / 144.75 5 71
6 13 163.36 20 15.13 592 179 4.52 / 144.93 5 71
7 8 -0.04 267 15.12 327 1320 5.84 / 146.25 6 135
Average= 18.28
(KJ/cycle)

Cycle 26 GMT 7/ 9/2022 18:56: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.32 38 15.09 477 274 0.27 / 134.79 6 19
2 7 2005.12 40 14.78 3138 1855 2.13 / 136.65 19 53
3 13 1907.64 20 14.77 2989 883 3.01 / 137.53 5 56
4 13 1577.56 20 14.78 2573 761 3.77 / 138.29 5 62
5 13 1000.36 20 14.89 1787 532 4.30 / 138.82 5 70
6 13 322.84 20 15.08 844 255 4.56 / 139.08 5 76
7 8 -0.08 267 15.11 332 1339 5.90 / 140.42 6 133
Average= 20.06
(KJ/cycle)

Cycle 25 GMT 28/ 8/2022 22:11: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.92 38 15.11 463 266 0.27 / 129.05 6 19
2 7 2012.08 40 14.77 3150 1861 2.13 / 130.91 19 54
3 13 1923.76 20 14.76 3059 903 3.03 / 131.81 5 56
4 13 1487.84 20 14.80 2461 728 3.76 / 132.54 5 65
5 13 831.04 20 14.94 1569 469 4.23 / 133.01 5 74
6 13 170.80 20 15.13 612 185 4.41 / 133.20 5 71
7 8 -0.16 265 15.12 330 1322 5.73 / 134.52 6 136
Average= 22.42
(KJ/cycle)

Cycle 24 GMT 19/ 8/2022 1:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.20 38 15.11 486 279 0.28 / 123.32 6 17
2 7 2005.92 40 14.79 3129 1851 2.13 / 125.17 17 51
3 13 1911.36 20 14.78 3006 889 3.02 / 126.06 5 56
4 13 1480.92 20 14.81 2452 726 3.75 / 126.79 5 65
5 13 925.24 20 14.91 1709 510 4.25 / 127.30 5 72
6 13 146.16 20 15.15 569 172 4.43 / 127.47 5 71
7 8 0.04 267 15.13 325 1313 5.74 / 128.78 6 136
Average= 25.76
(KJ/cycle)

Cycle 23 GMT 9/ 8/2022 4:25: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.56 37 15.12 452 253 0.25 / 117.46 6 17
2 7 2007.68 40 14.79 3146 1861 2.11 / 119.32 36 51
3 13 1924.16 20 14.78 3029 895 3.01 / 120.22 5 58
4 13 1413.40 20 14.83 2337 693 3.70 / 120.91 5 64
5 13 1003.00 20 14.90 1793 534 4.24 / 121.44 5 73
6 13 222.72 20 15.12 689 208 4.45 / 121.65 5 74
7 8 -0.08 270 15.12 341 1392 5.84 / 123.04 6 144
Average= 30.76
(KJ/cycle)

Cycle 22 GMT 30/ 7/2022 7:11: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.08 37 15.13 452 253 0.25 / 111.76 6 17
2 7 2013.44 40 14.79 3139 1857 2.11 / 113.62 17 51
3 13 1935.92 20 14.78 3042 899 3.01 / 114.52 5 57
4 13 1434.32 20 14.83 2367 702 3.71 / 115.22 5 66
5 13 797.28 20 14.96 1521 455 4.17 / 115.68 5 76
6 13 258.64 20 15.11 747 226 4.39 / 115.90 5 75
7 8 -0.08 265 15.13 325 1303 5.70 / 117.21 6 131
Average= 39.07
(KJ/cycle)

Cycle 21 GMT 20/ 7/2022 10: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.56 37 15.13 454 254 0.25 / 106.19 6 17
2 7 2005.12 40 14.80 3130 1853 2.11 / 108.04 17 53
3 13 1806.48 20 14.81 2867 849 2.96 / 108.89 5 59
4 13 1210.92 20 14.89 2063 614 3.57 / 109.51 5 69
5 13 922.16 20 14.93 1663 497 4.07 / 110.00 5 73
6 13 252.96 20 15.12 736 223 4.29 / 110.22 5 74
7 8 -0.04 263 15.14 323 1286 5.58 / 111.51 6 135
Average= 55.76
(KJ/cycle)

Cycle 20 GMT 10/ 7/2022 12:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.12 37 15.13 460 258 0.26 / 100.53 6 15
2 7 2007.88 41 14.79 3135 1901 2.16 / 102.43 15 53
3 13 1925.84 20 14.79 3032 897 3.06 / 103.33 5 57
4 13 1397.64 20 14.85 2306 685 3.74 / 104.02 5 66
5 13 855.60 20 14.95 1586 474 4.21 / 104.49 5 74
6 13 97.96 20 15.18 493 150 4.36 / 104.64 5 69
7 8 -0.04 263 15.14 325 1294 5.66 / 105.93 6 134
Average= 105.93
(KJ/cycle)

Cycle 18 GMT 20/ 6/2022 18:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.72 37 15.13 476 266 0.27 / 94.77 6 15
2 7 2008.84 40 14.81 3127 1852 2.12 / 96.63 15 52
3 13 1931.92 20 14.80 3034 898 3.02 / 97.52 5 56
4 13 1397.20 20 14.86 2313 687 3.70 / 98.21 5 65
5 13 869.44 20 14.95 1620 484 4.19 / 98.70 5 73
6 13 305.68 20 15.11 819 248 4.44 / 98.94 5 77
7 8 0.08 265 15.14 332 1332 5.77 / 100.28 6 131
Average= 5.28
(KJ/cycle)

Cycle 17 GMT 10/ 6/2022 21:34: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 37 15.15 448 251 0.25 / 88.84 6 16
2 7 2003.36 40 14.82 3138 1860 2.11 / 90.70 16 52
3 13 1912.40 20 14.81 3015 893 3.00 / 91.59 5 57
4 13 1593.00 20 14.82 2579 764 3.77 / 92.36 5 64
5 13 836.04 20 14.97 1570 470 4.24 / 92.83 5 74
6 13 498.28 20 15.05 1095 330 4.57 / 93.16 5 77
7 8 -0.04 265 15.14 337 1352 5.92 / 94.51 6 133
Average= 5.25
(KJ/cycle)

Cycle 16 GMT 1/ 6/2022 0:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.68 37 15.14 464 260 0.26 / 82.97 6 14
2 7 2009.04 41 14.81 3136 1904 2.16 / 84.87 14 52
3 13 1819.96 20 14.83 2890 857 3.02 / 85.73 5 58
4 13 1616.32 20 14.81 2610 773 3.79 / 86.50 5 62
5 13 1142.40 20 14.89 1960 584 4.38 / 87.08 5 70
6 13 122.64 20 15.18 537 163 4.54 / 87.25 5 72
7 8 -0.08 265 15.15 334 1341 5.88 / 88.59 6 141
Average= 5.21
(KJ/cycle)

Cycle 15 GMT 22/ 5/2022 3:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 37 15.15 449 252 0.25 / 77.18 6 15
2 7 2005.44 40 14.81 3147 1864 2.12 / 79.04 15 53
3 13 1916.28 20 14.82 3015 894 3.01 / 79.93 5 57
4 13 1592.88 20 14.83 2569 762 3.77 / 80.70 5 65
5 13 908.72 20 14.95 1673 500 4.27 / 81.20 5 74
6 13 220.40 20 15.15 683 207 4.48 / 81.40 5 74
7 8 -0.04 265 15.16 324 1302 5.78 / 82.71 6 132
Average= 5.17
(KJ/cycle)

Cycle 14 GMT 12/ 5/2022 6:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.04 37 15.16 451 253 0.25 / 71.48 6 13
2 7 2014.44 40 14.81 3146 1864 2.12 / 73.34 13 53
3 13 1922.92 20 14.81 3029 897 3.01 / 74.24 5 57
4 13 1379.28 20 14.87 2301 684 3.70 / 74.93 5 67
5 13 934.48 20 14.95 1672 500 4.20 / 75.43 5 73
6 13 245.16 20 15.15 722 219 4.42 / 75.65 5 76
7 8 -0.12 263 15.16 321 1280 5.70 / 76.92 6 130
Average= 5.13
(KJ/cycle)

Cycle 13 GMT 2/ 5/2022 9:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.16 37 15.15 432 242 0.24 / 65.79 6 12
2 7 2004.44 40 14.83 3142 1864 2.11 / 67.65 12 52
3 13 1913.52 20 14.82 3003 890 3.00 / 68.54 5 56
4 13 1285.48 20 14.90 2179 649 3.65 / 69.19 5 68
5 13 964.08 20 14.94 1756 525 4.17 / 69.71 5 73
6 13 201.76 20 15.16 659 200 4.37 / 69.91 5 74
7 8 -0.08 265 15.16 327 1314 5.68 / 71.23 6 137
Average= 5.09
(KJ/cycle)

Cycle 12 GMT 22/ 4/2022 12:50: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.60 37 15.16 438 246 0.25 / 60.13 6 13
2 7 2006.64 40 14.83 3138 1861 2.11 / 61.99 13 52
3 13 1805.12 20 14.85 2852 847 2.95 / 62.84 5 58
4 13 1488.24 20 14.86 2423 720 3.67 / 63.56 5 64
5 13 859.68 20 14.97 1619 485 4.16 / 64.04 5 75
6 13 189.04 20 15.17 635 193 4.35 / 64.23 5 74
7 8 -0.04 265 15.16 326 1310 5.66 / 65.54 6 132
Average= 5.04
(KJ/cycle)

Cycle 11 GMT 12/ 4/2022 15:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.60 37 15.17 442 248 0.25 / 54.33 6 12
2 7 2007.80 40 14.84 3123 1854 2.10 / 56.19 28 52
3 13 1918.68 20 14.83 3027 898 3.00 / 57.08 5 56
4 13 1614.76 20 14.83 2613 775 3.77 / 57.86 5 63
5 13 933.32 20 14.96 1692 506 4.28 / 58.37 5 73
6 13 291.44 20 15.14 762 231 4.51 / 58.60 5 76
7 8 -0.24 265 15.17 320 1286 5.80 / 59.88 6 131
Average= 4.99
(KJ/cycle)

Cycle 10 GMT 2/ 4/2022 18:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.80 37 15.16 425 238 0.24 / 48.67 6 12
2 7 2014.04 40 14.83 3157 1873 2.11 / 50.55 12 52
3 13 1925.96 20 14.83 3039 901 3.01 / 51.45 5 56
4 13 1391.40 20 14.89 2309 688 3.70 / 52.14 5 66
5 13 950.96 20 14.97 1682 504 4.20 / 52.64 5 72
6 13 169.32 20 15.18 600 182 4.39 / 52.82 5 73
7 8 -0.12 267 15.17 312 1264 5.65 / 54.09 6 140
Average= 4.92
(KJ/cycle)

Cycle 9 GMT 23/ 3/2022 21:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.12 37 15.17 426 239 0.24 / 43.00 6 12
2 7 2003.40 40 14.85 3129 1859 2.10 / 44.86 12 53
3 13 1911.36 20 14.84 3011 894 2.99 / 45.75 5 56
4 13 1384.08 20 14.89 2308 687 3.68 / 46.44 5 67
5 13 846.12 20 14.99 1567 470 4.15 / 46.91 5 74
6 13 304.88 20 15.14 781 236 4.38 / 47.15 5 76
7 13 35.08 20 15.22 375 114 4.50 / 47.26 6 67
8 8 -0.16 246 15.17 315 1176 5.67 / 48.44 6 131
Average= 4.84
(KJ/cycle)

Cycle 8 GMT 14/ 3/2022 0:34: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.96 37 15.16 460 258 0.26 / 37.45 6 12
2 7 2004.04 40 14.85 3131 1860 2.12 / 39.31 12 53
3 13 1909.28 20 14.85 2983 886 3.00 / 40.20 5 56
4 13 1401.16 20 14.89 2309 688 3.69 / 40.89 5 65
5 13 754.48 20 15.02 1463 439 4.13 / 41.33 5 74
6 13 110.04 20 15.21 507 154 4.29 / 41.48 5 70
7 8 -0.04 267 15.18 316 1281 5.57 / 42.76 6 131
Average= 4.75
(KJ/cycle)

Cycle 7 GMT 4/ 3/2022 3:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.92 36 15.17 460 251 0.25 / 31.63 6 12
2 3 1019.00 1 15.23 1833 28 0.28 / 31.66 5 36
3 7 2004.64 40 14.85 3132 1860 2.14 / 33.52 36 52
4 13 1912.32 20 14.85 3010 894 3.03 / 34.41 5 56
5 13 1590.24 20 14.86 2576 766 3.80 / 35.18 5 63
6 13 913.40 20 14.98 1666 499 4.30 / 35.68 5 72
7 13 128.88 20 15.20 545 166 4.46 / 35.84 5 71
8 13 24.04 20 15.23 383 117 4.58 / 35.96 6 65
9 8 -0.20 249 15.17 327 1235 5.82 / 37.20 6 138
Average= 4.65
(KJ/cycle)

Cycle 6 GMT 22/ 2/2022 6:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.24 36 15.16 438 239 0.24 / 25.97 6 12
2 3 1029.56 1 15.20 1855 28 0.27 / 25.99 5 43
3 7 2006.36 41 14.85 3130 1906 2.17 / 27.90 43 52
4 13 1915.48 20 14.84 3018 896 3.07 / 28.80 5 57
5 13 1386.92 20 14.90 2306 687 3.76 / 29.48 5 67
6 13 734.40 20 15.03 1415 425 4.18 / 29.91 5 76
7 13 100.88 20 15.22 472 144 4.32 / 30.05 5 70
8 8 -0.04 270 15.18 324 1328 5.65 / 31.38 6 143
Average= 4.48
(KJ/cycle)

Cycle 5 GMT 12/ 2/2022 9:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.56 31 15.17 478 225 0.22 / 20.08 6 12
2 10 1035.84 3 15.14 1846 84 0.31 / 20.16 5 49
3 3 1082.16 2 15.17 1925 58 0.37 / 20.22 5 59
4 7 2004.12 40 14.87 3136 1865 2.23 / 22.09 59 52
5 13 1905.92 20 14.86 3016 896 3.13 / 22.98 5 56
6 13 1375.36 20 14.91 2288 682 3.81 / 23.67 5 66
7 13 851.52 20 15.00 1575 472 4.28 / 24.14 5 74
8 13 186.32 20 15.19 615 187 4.47 / 24.33 5 74
9 8 -0.24 270 15.17 342 1401 5.87 / 25.73 6 133
Average= 4.29
(KJ/cycle)

Cycle 4 GMT 2/ 2/2022 12:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.44 36 15.16 474 259 0.26 / 15.14 6 13
2 7 1514.64 41 15.01 2456 1511 1.77 / 16.65 13 57
3 13 1450.20 20 15.00 2379 714 2.48 / 17.36 5 61
4 13 1152.80 20 15.00 1978 593 3.08 / 17.96 5 67
5 13 614.32 20 15.09 1266 382 3.46 / 18.34 5 75
6 13 37.80 20 15.25 407 124 3.58 / 18.46 6 64
7 8 0.00 267 15.19 343 1391 4.97 / 19.86 6 143
Average= 3.97
(KJ/cycle)

Cycle 3 GMT 1/ 2/2022 2: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.08 35 15.16 476 253 0.25 / 10.12 6 15
2 7 1509.40 40 15.01 2488 1494 1.75 / 11.61 18 58
3 13 1439.04 20 15.00 2388 716 2.46 / 12.33 5 62
4 13 1241.64 20 14.98 2129 638 3.10 / 12.97 5 67
5 13 698.48 20 15.07 1381 416 3.52 / 13.38 5 75
6 13 34.88 20 15.25 396 121 3.64 / 13.50 6 64
7 8 0.08 267 15.18 340 1378 5.02 / 14.88 6 136
Average= 3.72
(KJ/cycle)

Cycle 2 GMT 30/ 1/2022 15:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.80 31 15.20 447 211 0.21 / 5.13 6 12
2 10 1034.08 3 15.16 1849 84 0.29 / 5.22 5 48
3 3 1055.00 1 15.20 1871 28 0.32 / 5.25 5 53
4 7 1517.84 40 15.01 2454 1473 1.80 / 6.72 53 56
5 13 1450.64 20 15.00 2377 713 2.51 / 7.43 5 61
6 13 1141.92 20 15.01 1966 590 3.10 / 8.02 5 67
7 13 631.24 20 15.09 1255 379 3.48 / 8.40 5 74
8 13 38.40 20 15.24 378 115 3.59 / 8.52 6 65
9 8 -0.08 265 15.18 335 1348 4.94 / 9.87 6 135
Average= 3.29
(KJ/cycle)

Cycle 1 GMT 29/ 1/2022 5:39: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.20 31 15.44 399 191 0.19 / 1.90 6 9
2 10 1044.84 3 15.22 1843 84 0.28 / 1.99 5 48
3 3 1058.56 1 15.23 1882 29 0.30 / 2.02 5 58
4 7 1021.56 40 15.12 1798 1087 1.39 / 3.10 58 63
5 13 615.04 20 15.18 1248 379 1.77 / 3.48 5 72
6 13 16.96 20 15.31 361 111 1.88 / 3.59 6 59
7 8 -0.12 264 15.24 331 1332 3.21 / 4.92 6 129
Average= 2.46
(KJ/cycle)

Cycle 0 GMT 28/ 1/2022 18:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 124.40 30 15.62 419 196 0.20 / 0.20 6 13
2 7 134.20 40 15.60 423 264 0.46 / 0.46 13 15
3 13 92.80 20 15.59 373 116 0.58 / 0.58 6 18
4 13 25.44 20 15.58 277 86 0.66 / 0.66 6 20
5 8 0.16 267 15.52 253 1048 1.71 / 1.71 6 133
Average= 1.71
(KJ/cycle)