Cycle 107 GMT 21/11/2024 17:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.44 37 14.98 446 247 0.25 / 561.72 6 25
2 7 2009.72 40 14.63 3099 1814 2.06 / 563.54 25 57
3 13 1921.12 20 14.62 3001 877 2.94 / 564.41 5 61
4 13 1391.52 20 14.66 2282 669 3.61 / 565.08 5 69
5 13 771.28 20 14.79 1440 426 4.03 / 565.51 5 80
6 13 123.76 20 15.01 496 149 4.18 / 565.66 6 66
7 8 0.00 248 14.99 297 1104 5.29 / 566.76 6 133
Average= 6.37
(KJ/cycle)

Cycle 106 GMT 11/11/2024 20:30: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.32 37 14.99 439 243 0.24 / 556.25 6 23
2 7 2010.76 40 14.64 3106 1819 2.06 / 558.07 23 55
3 13 1928.52 20 14.62 3006 879 2.94 / 558.95 5 59
4 13 1494.84 20 14.64 2435 713 3.65 / 559.66 5 71
5 13 944.92 20 14.74 1689 498 4.15 / 560.16 5 78
6 13 251.72 20 14.96 699 209 4.36 / 560.37 5 73
7 8 -0.04 248 14.99 298 1108 5.47 / 561.48 6 136
Average= 6.38
(KJ/cycle)

Cycle 105 GMT 1/11/2024 23:34: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.52 37 14.99 444 246 0.25 / 550.94 6 25
2 7 2005.24 40 14.65 3072 1800 2.05 / 552.74 25 56
3 13 1917.12 20 14.62 2964 867 2.91 / 553.60 5 61
4 13 1287.72 20 14.69 2153 633 3.55 / 554.24 5 71
5 13 961.68 20 14.74 1708 504 4.05 / 554.74 5 77
6 13 175.88 20 14.99 577 173 4.22 / 554.91 6 69
7 8 0.08 248 15.00 294 1094 5.32 / 556.01 6 134
Average= 6.39
(KJ/cycle)

Cycle 104 GMT 23/10/2024 2:38: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.64 37 14.99 429 238 0.24 / 545.55 6 28
2 7 2014.20 40 14.64 3114 1824 2.06 / 547.37 28 57
3 13 1932.12 20 14.62 3006 879 2.94 / 548.25 5 60
4 13 1425.04 20 14.66 2333 684 3.62 / 548.93 5 69
5 13 985.28 20 14.73 1732 510 4.13 / 549.44 5 75
6 13 95.28 20 15.03 448 135 4.27 / 549.58 6 64
7 8 0.00 248 15.00 299 1112 5.38 / 550.69 6 129
Average= 6.40
(KJ/cycle)

Cycle 103 GMT 13/10/2024 5:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.20 37 14.99 427 237 0.24 / 540.11 6 27
2 7 2006.52 40 14.64 3102 1817 2.05 / 541.93 27 55
3 13 1916.88 20 14.62 2994 875 2.93 / 542.80 5 59
4 13 1482.12 20 14.64 2405 704 3.63 / 543.51 5 66
5 13 1025.32 20 14.72 1797 529 4.16 / 544.04 5 76
6 13 129.60 20 15.02 505 152 4.31 / 544.19 6 68
7 8 0.16 249 14.99 300 1120 5.43 / 545.31 6 144
Average= 6.42
(KJ/cycle)

Cycle 102 GMT 3/10/2024 8:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.12 37 14.99 449 249 0.25 / 534.79 6 25
2 7 2005.48 40 14.64 3111 1822 2.07 / 536.61 62 56
3 13 1917.12 20 14.63 2991 875 2.95 / 537.49 5 63
4 13 1184.48 20 14.71 2018 594 3.54 / 538.08 5 73
5 13 978.80 20 14.73 1733 511 4.05 / 538.59 5 76
6 13 190.56 20 14.99 607 182 4.23 / 538.78 6 72
7 8 0.16 246 15.00 298 1100 5.33 / 539.88 6 134
Average= 6.43
(KJ/cycle)

Cycle 101 GMT 23/ 9/2024 11:58: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.16 37 14.99 447 248 0.25 / 529.41 6 23
2 7 2004.68 40 14.65 3087 1809 2.06 / 531.22 23 57
3 13 1918.68 20 14.63 2997 877 2.93 / 532.10 5 63
4 13 1366.68 20 14.67 2248 660 3.59 / 532.75 5 71
5 13 1023.84 20 14.72 1795 528 4.12 / 533.28 5 76
6 13 127.12 20 15.02 502 151 4.27 / 533.43 6 68
7 8 0.04 250 15.00 296 1110 5.38 / 534.54 6 138
Average= 6.44
(KJ/cycle)

Cycle 100 GMT 13/ 9/2024 15:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.72 37 14.99 447 248 0.25 / 524.00 6 26
2 7 2003.88 41 14.64 3121 1873 2.12 / 525.87 26 57
3 13 1914.00 20 14.63 2999 878 3.00 / 526.75 5 61
4 13 1380.32 20 14.67 2278 668 3.67 / 527.42 5 71
5 13 828.80 20 14.78 1540 455 4.12 / 527.88 5 81
6 13 170.92 20 15.00 579 174 4.30 / 528.05 6 74
7 8 0.04 244 14.99 304 1112 5.41 / 529.16 6 133
Average= 6.45
(KJ/cycle)

Cycle 99 GMT 3/ 9/2024 18:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.28 37 14.99 441 245 0.24 / 518.72 6 27
2 7 2006.80 40 14.64 3097 1814 2.06 / 520.53 27 59
3 13 1923.08 20 14.63 2988 874 2.93 / 521.41 5 60
4 13 1485.84 20 14.65 2418 708 3.64 / 522.12 5 68
5 13 717.52 20 14.82 1364 404 4.05 / 522.52 5 81
6 13 88.52 20 15.03 444 133 4.18 / 522.65 6 65
7 8 0.00 246 15.00 298 1100 5.28 / 523.75 6 131
Average= 6.47
(KJ/cycle)

Cycle 98 GMT 24/ 8/2024 21: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.56 37 14.99 438 243 0.24 / 513.36 6 25
2 7 2015.56 40 14.64 3117 1825 2.07 / 515.19 36 58
3 13 1928.96 20 14.62 3009 880 2.95 / 516.07 5 60
4 13 1388.96 20 14.67 2284 670 3.62 / 516.74 5 69
5 13 847.20 20 14.77 1551 458 4.08 / 517.19 5 78
6 13 172.28 20 15.00 575 172 4.25 / 517.37 5 72
7 8 0.08 248 15.00 298 1109 5.36 / 518.48 6 139
Average= 6.48
(KJ/cycle)

Cycle 97 GMT 15/ 8/2024 0: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.88 37 14.99 424 235 0.24 / 508.01 6 25
2 7 2004.20 40 14.65 3081 1805 2.04 / 509.82 25 58
3 13 1911.32 20 14.64 2978 872 2.91 / 510.69 5 60
4 13 1480.92 20 14.65 2414 707 3.62 / 511.39 5 69
5 13 830.68 20 14.79 1531 453 4.07 / 511.85 5 78
6 13 166.40 20 15.00 564 169 4.24 / 512.02 6 70
7 8 0.00 248 15.00 296 1101 5.34 / 513.12 6 132
Average= 6.50
(KJ/cycle)

Cycle 96 GMT 5/ 8/2024 3: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.12 37 14.99 447 248 0.25 / 502.62 6 26
2 7 2005.88 40 14.65 3097 1815 2.06 / 504.44 26 56
3 13 1917.52 20 14.63 2976 871 2.93 / 505.31 5 62
4 13 1480.56 20 14.65 2403 704 3.64 / 506.01 5 69
5 13 797.32 20 14.79 1485 439 4.08 / 506.45 5 80
6 13 242.68 20 14.97 689 206 4.28 / 506.66 5 74
7 8 0.16 248 14.99 301 1119 5.40 / 507.77 6 136
Average= 6.51
(KJ/cycle)

Cycle 95 GMT 26/ 7/2024 6:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.16 37 14.99 438 243 0.24 / 497.18 6 26
2 7 2017.08 40 14.65 3110 1822 2.07 / 499.01 26 58
3 13 1937.24 20 14.63 2992 875 2.94 / 499.88 5 62
4 13 1495.28 20 14.65 2420 709 3.65 / 500.59 5 69
5 13 828.60 20 14.79 1523 451 4.10 / 501.04 5 79
6 13 269.32 20 14.96 730 218 4.32 / 501.26 6 76
7 8 0.04 248 15.00 299 1112 5.43 / 502.37 6 135
Average= 6.52
(KJ/cycle)

Cycle 94 GMT 16/ 7/2024 9:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.12 37 14.99 435 241 0.24 / 491.91 6 24
2 7 2009.64 40 14.66 3069 1800 2.04 / 493.71 24 57
3 13 1816.12 20 14.65 2843 833 2.87 / 494.55 5 62
4 13 1385.92 20 14.68 2265 665 3.54 / 495.21 5 69
5 13 831.80 20 14.78 1527 451 3.99 / 495.66 5 78
6 13 171.20 20 15.00 575 172 4.16 / 495.83 6 71
7 8 0.04 246 15.00 300 1107 5.27 / 496.94 6 132
Average= 6.54
(KJ/cycle)

Cycle 93 GMT 6/ 7/2024 12:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.96 37 14.99 425 236 0.24 / 486.58 6 25
2 7 2013.04 40 14.65 3119 1828 2.06 / 488.41 25 59
3 13 1917.64 20 14.63 2986 874 2.94 / 489.29 5 62
4 13 1370.72 20 14.68 2247 660 3.60 / 489.95 5 71
5 13 835.24 20 14.78 1530 452 4.05 / 490.40 5 80
6 13 164.80 20 15.00 561 168 4.22 / 490.57 6 70
7 8 -0.04 248 15.00 297 1105 5.32 / 491.67 6 132
Average= 6.56
(KJ/cycle)

Cycle 92 GMT 26/ 6/2024 15:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.04 37 14.99 443 246 0.25 / 481.20 6 25
2 7 2015.20 40 14.65 3111 1823 2.07 / 483.03 25 57
3 13 1922.84 20 14.64 2988 875 2.94 / 483.90 5 61
4 13 1383.60 20 14.67 2271 666 3.61 / 484.57 5 70
5 13 834.68 20 14.78 1537 454 4.06 / 485.02 5 79
6 13 272.24 20 14.96 727 218 4.28 / 485.24 6 73
7 8 0.08 248 15.00 298 1109 5.39 / 486.35 6 136
Average= 6.57
(KJ/cycle)

Cycle 91 GMT 16/ 6/2024 18:34: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.28 37 15.00 430 239 0.24 / 475.81 6 24
2 7 2015.00 41 14.64 3115 1870 2.11 / 477.68 24 56
3 13 1922.12 20 14.63 3006 880 2.99 / 478.56 5 64
4 13 1360.44 20 14.68 2248 660 3.65 / 479.22 5 70
5 13 920.64 20 14.76 1651 487 4.14 / 479.70 5 79
6 13 134.40 20 15.02 511 154 4.29 / 479.86 6 66
7 8 0.00 248 15.00 296 1101 5.39 / 480.96 6 138
Average= 6.59
(KJ/cycle)

Cycle 90 GMT 6/ 6/2024 21:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.36 37 14.99 429 238 0.24 / 470.50 6 23
2 7 2008.12 40 14.65 3112 1824 2.06 / 472.32 23 58
3 13 1922.24 20 14.63 2999 878 2.94 / 473.20 5 62
4 13 1479.04 20 14.65 2410 706 3.65 / 473.90 5 69
5 13 818.08 20 14.79 1513 448 4.09 / 474.35 5 80
6 13 81.84 20 15.04 429 129 4.22 / 474.48 6 62
7 8 0.12 246 15.01 295 1089 5.31 / 475.57 6 131
Average= 6.61
(KJ/cycle)

Cycle 89 GMT 28/ 5/2024 0:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.16 37 15.00 443 246 0.25 / 465.21 6 23
2 7 2008.24 40 14.66 3102 1819 2.06 / 467.03 23 59
3 13 1927.52 20 14.64 2995 877 2.94 / 467.90 5 62
4 13 1286.00 20 14.71 2136 628 3.57 / 468.53 5 71
5 13 765.64 20 14.81 1433 424 3.99 / 468.95 5 79
6 13 213.96 20 14.99 641 192 4.19 / 469.15 6 73
7 8 0.00 246 15.00 301 1111 5.30 / 470.26 6 130
Average= 6.62
(KJ/cycle)

Cycle 88 GMT 18/ 5/2024 3:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.72 37 15.00 437 243 0.24 / 459.92 6 22
2 7 2006.00 41 14.65 3079 1849 2.09 / 461.77 22 55
3 13 1916.52 20 14.63 2991 875 2.97 / 462.65 5 60
4 13 1389.68 20 14.67 2275 667 3.63 / 463.32 5 70
5 13 743.20 20 14.81 1404 416 4.05 / 463.73 5 80
6 13 87.28 20 15.03 443 133 4.18 / 463.87 6 67
7 8 0.04 244 15.00 299 1094 5.28 / 464.96 6 129
Average= 6.64
(KJ/cycle)

Cycle 87 GMT 8/ 5/2024 6:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.92 37 15.00 426 236 0.24 / 454.61 6 22
2 7 2006.72 40 14.65 3104 1819 2.06 / 456.43 51 56
3 13 1923.12 20 14.64 2970 870 2.92 / 457.30 5 59
4 13 1379.28 20 14.67 2263 664 3.59 / 457.96 5 70
5 13 826.80 20 14.78 1532 453 4.04 / 458.41 5 79
6 13 81.88 20 15.03 444 133 4.18 / 458.55 6 64
7 8 0.24 249 15.00 304 1135 5.31 / 459.68 6 140
Average= 6.66
(KJ/cycle)

Cycle 86 GMT 28/ 4/2024 9:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.36 37 14.99 428 237 0.24 / 449.29 6 24
2 7 2015.28 41 14.65 3096 1860 2.10 / 451.15 61 58
3 13 1925.60 20 14.63 3018 883 2.98 / 452.03 5 63
4 13 1402.20 20 14.67 2307 677 3.66 / 452.71 5 68
5 13 774.08 20 14.81 1445 428 4.08 / 453.14 5 79
6 13 72.28 20 15.04 425 128 4.21 / 453.27 6 64
7 8 0.00 248 15.00 297 1105 5.32 / 454.37 6 132
Average= 6.68
(KJ/cycle)

Cycle 85 GMT 18/ 4/2024 12:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.08 37 14.99 430 238 0.24 / 443.85 6 22
2 7 2006.24 40 14.65 3121 1829 2.07 / 445.68 22 57
3 13 1914.84 20 14.64 2991 876 2.94 / 446.56 5 63
4 13 1379.76 20 14.68 2275 668 3.61 / 447.23 5 71
5 13 844.28 20 14.78 1558 461 4.07 / 447.69 5 80
6 13 288.48 20 14.96 759 227 4.30 / 447.91 5 76
7 8 -0.08 248 14.99 307 1141 5.44 / 449.05 6 138
Average= 6.70
(KJ/cycle)

Cycle 84 GMT 8/ 4/2024 15: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 37 14.98 429 238 0.24 / 438.59 6 19
2 7 2015.52 40 14.66 3096 1815 2.05 / 440.41 19 57
3 13 1929.72 20 14.64 2972 870 2.92 / 441.28 5 60
4 13 1375.04 20 14.69 2243 659 3.58 / 441.94 5 68
5 13 738.28 20 14.82 1396 414 4.00 / 442.35 5 79
6 13 98.44 20 15.03 469 141 4.14 / 442.49 6 68
7 8 0.04 248 15.00 301 1120 5.26 / 443.61 6 136
Average= 6.72
(KJ/cycle)

Cycle 83 GMT 29/ 3/2024 18: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.24 37 14.99 432 240 0.24 / 433.22 6 20
2 7 2005.88 40 14.66 3079 1806 2.05 / 435.02 20 58
3 13 1922.92 20 14.63 3000 878 2.92 / 435.90 5 61
4 13 1203.92 20 14.72 2030 598 3.52 / 436.50 5 73
5 13 999.40 20 14.73 1760 518 4.04 / 437.02 5 76
6 13 203.60 20 14.99 627 188 4.23 / 437.21 6 75
7 8 0.12 250 14.99 307 1150 5.38 / 438.36 6 144
Average= 6.74
(KJ/cycle)

Cycle 82 GMT 19/ 3/2024 21: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.28 37 14.99 436 242 0.24 / 427.91 6 20
2 7 2004.56 41 14.65 3118 1873 2.11 / 429.78 20 59
3 13 1806.92 20 14.66 2844 834 2.95 / 430.61 5 64
4 13 1403.12 20 14.67 2304 676 3.62 / 431.29 5 70
5 13 851.84 20 14.77 1563 462 4.09 / 431.75 5 79
6 13 51.16 20 15.04 394 119 4.20 / 431.87 6 63
7 8 0.04 246 15.00 301 1111 5.32 / 432.98 6 132
Average= 6.77
(KJ/cycle)

Cycle 81 GMT 9/ 3/2024 23:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.20 37 14.98 429 238 0.24 / 422.55 6 20
2 7 2007.32 41 14.66 3084 1854 2.09 / 424.40 20 57
3 13 1922.92 20 14.64 2987 875 2.97 / 425.28 5 59
4 13 1346.56 20 14.69 2211 650 3.62 / 425.93 5 67
5 13 803.40 20 14.79 1493 442 4.06 / 426.37 5 80
6 13 149.28 20 15.01 544 163 4.22 / 426.53 6 70
7 8 0.04 248 14.99 305 1134 5.35 / 427.66 6 137
Average= 6.79
(KJ/cycle)

Cycle 80 GMT 29/ 2/2024 2:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.24 37 14.98 442 245 0.24 / 417.09 6 20
2 7 2004.52 41 14.66 3090 1857 2.10 / 418.95 45 56
3 13 1911.92 20 14.65 2965 869 2.97 / 419.82 5 61
4 13 1360.52 20 14.68 2242 658 3.63 / 420.48 5 71
5 13 910.04 20 14.76 1644 485 4.11 / 420.96 5 79
6 13 209.80 20 14.98 639 191 4.31 / 421.15 6 71
7 8 0.04 248 14.99 311 1156 5.46 / 422.31 6 133
Average= 6.81
(KJ/cycle)

Cycle 79 GMT 19/ 2/2024 6: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.40 37 14.98 437 242 0.24 / 411.63 6 19
2 7 2012.00 40 14.66 3081 1807 2.05 / 413.44 19 57
3 13 1921.64 20 14.65 2987 875 2.92 / 414.31 5 61
4 13 1456.08 20 14.66 2359 692 3.62 / 415.00 5 70
5 13 906.80 20 14.76 1637 483 4.10 / 415.49 5 76
6 13 238.96 20 14.97 677 203 4.30 / 415.69 6 72
7 13 22.40 20 15.03 351 106 4.41 / 415.79 6 65
8 8 -0.04 229 14.98 307 1053 5.46 / 416.85 6 133
Average= 6.83
(KJ/cycle)

Cycle 78 GMT 9/ 2/2024 9: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.36 37 14.98 439 243 0.24 / 406.24 6 17
2 7 2005.68 40 14.66 3091 1813 2.06 / 408.05 17 58
3 13 1915.48 20 14.64 2983 873 2.93 / 408.92 5 63
4 13 1472.16 20 14.65 2400 703 3.63 / 409.62 5 71
5 13 1010.28 20 14.72 1780 524 4.16 / 410.15 5 78
6 13 62.60 20 15.04 407 122 4.28 / 410.27 6 62
7 8 0.16 248 15.00 300 1116 5.39 / 411.39 6 137
Average= 6.86
(KJ/cycle)

Cycle 77 GMT 30/ 1/2024 12:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.84 37 14.98 451 250 0.25 / 400.77 6 21
2 7 2004.64 40 14.68 3071 1803 2.05 / 402.57 21 57
3 13 1910.04 20 14.66 2990 877 2.93 / 403.45 5 61
4 13 1470.12 20 14.66 2406 705 3.64 / 404.15 5 70
5 13 1014.20 20 14.73 1786 526 4.16 / 404.68 5 77
6 13 117.52 20 15.02 494 148 4.31 / 404.83 6 69
7 13 22.24 20 15.04 348 105 4.41 / 404.93 6 65
8 8 -0.04 231 14.99 306 1060 5.47 / 405.99 6 139
Average= 6.88
(KJ/cycle)

Cycle 76 GMT 20/ 1/2024 15:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.84 37 14.97 435 241 0.24 / 395.38 6 24
2 7 2006.64 40 14.67 3089 1813 2.05 / 397.19 24 58
3 13 1920.12 20 14.66 2974 872 2.93 / 398.07 5 60
4 13 1388.20 20 14.68 2282 670 3.60 / 398.74 5 70
5 13 843.40 20 14.78 1558 461 4.06 / 399.20 5 79
6 13 170.88 20 14.99 577 173 4.23 / 399.37 6 73
7 8 -0.04 248 14.98 309 1148 5.38 / 400.52 6 132
Average= 6.91
(KJ/cycle)

Cycle 75 GMT 10/ 1/2024 18:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 37 14.98 450 249 0.25 / 389.89 6 24
2 7 2005.76 40 14.67 3109 1824 2.07 / 391.71 24 57
3 13 1909.60 20 14.65 2978 873 2.95 / 392.58 5 62
4 13 1388.28 20 14.68 2309 678 3.62 / 393.26 5 68
5 13 938.84 20 14.75 1677 495 4.12 / 393.76 5 79
6 13 239.36 20 14.97 688 206 4.32 / 393.96 5 71
7 13 18.36 20 15.03 349 105 4.43 / 394.07 6 69
8 8 -0.20 227 14.97 316 1074 5.50 / 395.14 6 131
Average= 6.93
(KJ/cycle)

Cycle 74 GMT 31/12/2023 21:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.36 36 14.98 456 246 0.25 / 384.45 6 23
2 7 2003.24 41 14.67 3086 1856 2.10 / 386.30 64 57
3 13 1910.08 20 14.66 2960 868 2.97 / 387.17 5 62
4 13 1475.24 20 14.66 2385 699 3.67 / 387.87 5 70
5 13 801.76 20 14.79 1501 444 4.11 / 388.32 5 80
6 13 145.20 20 15.00 547 164 4.28 / 388.48 6 70
7 8 -0.08 246 14.98 314 1157 5.43 / 389.64 6 132
Average= 6.96
(KJ/cycle)

Cycle 73 GMT 22/12/2023 0:51: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.32 36 14.96 459 247 0.25 / 379.06 6 25
2 7 2013.96 40 14.67 3135 1840 2.09 / 380.90 25 58
3 13 1925.12 20 14.65 3006 881 2.97 / 381.78 5 62
4 13 1388.92 20 14.68 2296 674 3.64 / 382.45 5 71
5 13 836.76 20 14.78 1555 460 4.10 / 382.91 5 79
6 13 51.32 20 15.04 403 121 4.22 / 383.03 6 65
7 8 0.04 248 14.99 315 1171 5.39 / 384.20 6 138
Average= 6.99
(KJ/cycle)

Cycle 72 GMT 12/12/2023 3:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.20 36 14.98 465 251 0.25 / 373.83 6 24
2 7 1996.68 40 14.67 3102 1820 2.07 / 375.65 24 60
3 13 1899.68 20 14.65 2987 875 2.95 / 376.52 5 65
4 13 1156.88 20 14.73 1983 584 3.53 / 377.11 5 74
5 13 729.68 20 14.80 1399 414 3.94 / 377.52 5 83
6 13 44.24 20 15.03 394 118 4.06 / 377.64 6 68
7 8 0.04 244 14.98 320 1170 5.23 / 378.81 6 137
Average= 7.01
(KJ/cycle)

Cycle 71 GMT 2/12/2023 3: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.24 36 14.98 449 242 0.24 / 368.51 6 23
2 7 1949.64 40 14.69 3030 1780 2.02 / 370.29 23 60
3 13 1853.56 20 14.68 2908 854 2.88 / 371.14 5 63
4 13 1536.80 20 14.67 2482 728 3.60 / 371.87 5 68
5 13 776.84 20 14.81 1460 432 4.04 / 372.30 5 81
6 13 33.36 20 15.04 375 113 4.15 / 372.42 6 66
7 8 0.04 244 14.99 317 1159 5.31 / 373.58 6 134
Average= 7.05
(KJ/cycle)

Cycle 70 GMT 22/11/2023 2:10: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.32 36 14.97 452 244 0.24 / 363.14 6 28
2 7 2003.52 40 14.69 3096 1819 2.06 / 364.96 28 57
3 13 1905.52 20 14.67 2988 877 2.94 / 365.84 5 62
4 13 1368.08 20 14.70 2256 663 3.60 / 366.50 5 72
5 13 826.36 20 14.79 1526 451 4.05 / 366.95 5 82
6 13 155.52 20 15.00 564 169 4.22 / 367.12 6 75
7 8 -0.08 248 14.99 308 1145 5.37 / 368.27 6 140
Average= 7.08
(KJ/cycle)

Cycle 69 GMT 12/11/2023 5:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.32 36 14.96 467 252 0.25 / 357.80 6 29
2 7 2011.76 41 14.69 3092 1862 2.11 / 359.66 29 58
3 13 1823.16 20 14.68 2861 840 2.95 / 360.50 5 63
4 13 1306.28 20 14.71 2177 640 3.59 / 361.14 5 72
5 13 863.76 20 14.77 1584 468 4.06 / 361.61 5 80
6 13 86.32 20 15.03 461 139 4.20 / 361.74 6 71
7 8 0.20 246 14.99 313 1154 5.35 / 362.90 6 130
Average= 7.12
(KJ/cycle)

Cycle 68 GMT 2/11/2023 7:51:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.24 36 14.97 486 262 0.26 / 352.45 6 31
2 7 2005.68 40 14.68 3094 1817 2.08 / 354.27 31 59
3 13 1913.40 20 14.67 2994 878 2.96 / 355.14 5 61
4 13 1270.76 20 14.72 2134 628 3.59 / 355.77 5 72
5 13 836.04 20 14.79 1537 455 4.04 / 356.23 5 79
6 13 78.92 20 15.03 453 136 4.18 / 356.36 6 74
7 8 -0.04 244 14.98 323 1181 5.36 / 357.54 6 132
Average= 7.15
(KJ/cycle)

Cycle 67 GMT 23/10/2023 10:43:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.96 36 14.97 465 251 0.25 / 347.03 6 32
2 7 2005.84 40 14.69 3085 1813 2.06 / 348.85 32 57
3 13 1915.72 20 14.68 2983 876 2.94 / 349.72 5 63
4 13 1388.32 20 14.69 2284 671 3.61 / 350.39 5 70
5 13 833.32 20 14.79 1547 458 4.07 / 350.85 5 80
6 13 77.60 20 15.03 453 136 4.20 / 350.99 6 73
7 8 0.04 244 14.99 328 1200 5.40 / 352.19 6 133
Average= 7.19
(KJ/cycle)

Cycle 66 GMT 13/10/2023 13:38:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.60 36 14.98 470 253 0.25 / 341.59 6 33
2 7 2005.96 40 14.69 3127 1837 2.09 / 343.42 48 58
3 13 1917.68 20 14.67 3008 883 2.97 / 344.31 5 62
4 13 1375.12 20 14.70 2269 667 3.64 / 344.97 5 70
5 13 825.04 20 14.80 1533 454 4.09 / 345.43 5 80
6 13 82.64 20 15.03 463 139 4.23 / 345.57 6 73
7 8 0.12 246 14.99 330 1217 5.45 / 346.78 6 134
Average= 7.22
(KJ/cycle)

Cycle 65 GMT 3/10/2023 16:35:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.60 36 14.98 482 260 0.26 / 336.33 6 35
2 7 2004.44 40 14.69 3088 1815 2.07 / 338.15 42 58
3 13 1813.44 20 14.69 2875 845 2.92 / 338.99 5 65
4 13 1293.12 20 14.72 2164 637 3.56 / 339.63 5 73
5 13 659.76 20 14.85 1300 386 3.94 / 340.01 5 81
6 13 52.36 20 15.05 419 126 4.07 / 340.14 6 75
7 8 -0.04 242 15.00 329 1194 5.26 / 341.33 6 132
Average= 7.26
(KJ/cycle)

Cycle 64 GMT 23/ 9/2023 19:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.16 35 14.98 470 246 0.25 / 331.00 6 37
2 7 2005.04 40 14.69 3112 1829 2.08 / 332.83 37 55
3 13 1910.92 20 14.68 3008 883 2.96 / 333.71 5 62
4 13 1274.68 20 14.73 2141 631 3.59 / 334.34 5 72
5 13 730.24 20 14.83 1411 419 4.01 / 334.76 5 82
6 13 39.08 20 15.05 398 120 4.13 / 334.88 6 75
7 8 0.16 240 15.00 330 1188 5.32 / 336.07 6 132
Average= 7.31
(KJ/cycle)

Cycle 63 GMT 13/ 9/2023 22:26:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.64 35 14.98 483 253 0.25 / 325.60 6 35
2 7 2006.00 40 14.70 3098 1822 2.07 / 327.42 35 58
3 13 1921.88 20 14.69 2970 873 2.95 / 328.29 5 63
4 13 1283.08 20 14.73 2147 633 3.58 / 328.93 5 72
5 13 855.76 20 14.80 1582 468 4.05 / 329.39 5 79
6 13 171.68 20 15.01 592 178 4.23 / 329.57 5 78
7 13 14.12 20 15.05 351 106 4.33 / 329.68 5 75
8 8 -0.08 223 15.00 322 1077 5.41 / 330.76 6 137
Average= 7.35
(KJ/cycle)

Cycle 62 GMT 4/ 9/2023 1:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.68 35 14.99 485 254 0.25 / 320.17 6 34
2 7 2005.40 41 14.69 3128 1884 2.14 / 322.05 34 60
3 13 1910.00 20 14.68 3004 882 3.02 / 322.93 5 62
4 13 1353.92 20 14.72 2240 659 3.68 / 323.59 5 72
5 13 792.76 20 14.82 1490 442 4.12 / 324.03 5 83
6 13 64.08 20 15.06 428 129 4.25 / 324.16 6 73
7 8 0.12 242 15.01 326 1184 5.43 / 325.35 6 146
Average= 7.39
(KJ/cycle)

Cycle 61 GMT 25/ 8/2023 4:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.96 35 15.00 465 244 0.24 / 314.68 6 34
2 7 2005.40 40 14.71 3107 1828 2.07 / 316.51 34 59
3 13 1913.28 20 14.69 2982 876 2.95 / 317.39 5 62
4 13 1476.28 20 14.70 2423 712 3.66 / 318.10 5 71
5 13 815.44 20 14.82 1522 451 4.11 / 318.55 5 81
6 13 156.08 20 15.03 568 171 4.28 / 318.72 5 79
7 8 0.00 244 15.01 325 1190 5.47 / 319.91 6 138
Average= 7.44
(KJ/cycle)

Cycle 60 GMT 15/ 8/2023 7:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.44 35 15.00 464 244 0.24 / 309.33 6 33
2 7 2006.72 40 14.71 3110 1830 2.07 / 311.16 33 58
3 13 1918.84 20 14.68 3022 887 2.96 / 312.05 5 64
4 13 1374.44 20 14.72 2276 670 3.63 / 312.72 5 72
5 13 722.68 20 14.86 1379 410 4.04 / 313.13 5 81
6 13 85.88 20 15.06 466 140 4.18 / 313.27 6 75
7 8 0.04 242 15.02 322 1170 5.35 / 314.44 6 135
Average= 7.49
(KJ/cycle)

Cycle 59 GMT 5/ 8/2023 10:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.76 35 15.00 479 251 0.25 / 303.89 6 37
2 7 2004.52 40 14.71 3106 1828 2.08 / 305.72 37 58
3 13 1906.04 20 14.70 2972 874 2.95 / 306.59 5 64
4 13 1472.96 20 14.70 2420 711 3.66 / 307.31 5 70
5 13 799.92 20 14.83 1499 445 4.11 / 307.75 5 78
6 13 145.52 20 15.04 553 166 4.28 / 307.92 6 76
7 8 0.12 240 15.02 325 1172 5.45 / 309.09 6 134
Average= 7.54
(KJ/cycle)

Cycle 58 GMT 26/ 7/2023 13:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.80 35 15.00 476 250 0.25 / 298.37 6 36
2 7 2003.68 40 14.71 3106 1828 2.08 / 300.20 36 58
3 13 1910.60 20 14.69 3017 886 2.96 / 301.09 5 62
4 13 1475.76 20 14.71 2419 712 3.68 / 301.80 5 71
5 13 806.88 20 14.84 1518 451 4.13 / 302.25 5 81
6 13 236.40 20 15.01 701 210 4.34 / 302.46 5 77
7 8 0.04 242 15.02 325 1181 5.52 / 303.64 6 134
Average= 7.59
(KJ/cycle)

Cycle 57 GMT 16/ 7/2023 16:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.08 35 15.01 473 248 0.25 / 292.92 6 33
2 7 2014.36 40 14.71 3121 1836 2.08 / 294.76 33 57
3 13 1919.64 20 14.70 3002 883 2.97 / 295.64 5 63
4 13 1371.96 20 14.73 2265 667 3.63 / 296.31 5 72
5 13 830.08 20 14.83 1551 460 4.09 / 296.77 5 81
6 13 147.60 20 15.04 567 171 4.27 / 296.94 5 76
7 8 0.08 240 15.02 328 1182 5.45 / 298.12 6 132
Average= 7.64
(KJ/cycle)

Cycle 56 GMT 6/ 7/2023 19:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.04 35 15.02 459 241 0.24 / 287.52 6 30
2 7 2007.56 40 14.71 3104 1826 2.07 / 289.34 30 59
3 13 1923.32 20 14.69 3019 887 2.95 / 290.23 5 64
4 13 1377.44 20 14.73 2287 674 3.63 / 290.91 5 72
5 13 711.00 20 14.88 1382 411 4.04 / 291.32 5 85
6 13 134.68 20 15.05 548 165 4.20 / 291.48 5 77
7 8 -0.04 240 15.03 331 1194 5.40 / 292.68 6 131
Average= 7.70
(KJ/cycle)

Cycle 55 GMT 26/ 6/2023 22:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.36 35 15.02 479 252 0.25 / 282.20 6 33
2 7 2004.56 40 14.72 3089 1819 2.07 / 284.02 33 58
3 13 1716.64 20 14.72 2747 809 2.88 / 284.83 5 66
4 13 1515.32 20 14.70 2464 724 3.60 / 285.56 5 69
5 13 726.20 20 14.87 1398 416 4.02 / 285.97 5 81
6 13 85.32 20 15.08 464 140 4.16 / 286.11 6 75
7 8 0.12 242 15.04 320 1165 5.32 / 287.28 6 144
Average= 7.76
(KJ/cycle)

Cycle 54 GMT 17/ 6/2023 1:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.36 35 15.02 471 248 0.25 / 276.81 6 32
2 7 2008.40 40 14.71 3109 1829 2.08 / 278.64 32 58
3 13 1920.16 20 14.69 2982 876 2.95 / 279.52 5 63
4 13 1381.68 20 14.74 2270 669 3.62 / 280.19 5 71
5 13 819.84 20 14.85 1530 454 4.08 / 280.64 5 78
6 13 64.00 20 15.08 440 133 4.21 / 280.77 5 76
7 8 0.04 240 15.04 327 1180 5.39 / 281.95 6 134
Average= 7.83
(KJ/cycle)

Cycle 53 GMT 7/ 6/2023 4:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.36 35 15.03 468 246 0.25 / 271.46 6 29
2 7 2015.08 40 14.72 3106 1829 2.08 / 273.28 29 58
3 13 1924.36 20 14.70 2996 881 2.96 / 274.16 5 60
4 13 1372.20 20 14.75 2262 667 3.62 / 274.83 5 71
5 13 738.36 20 14.88 1413 421 4.04 / 275.25 5 79
6 13 46.28 20 15.09 410 124 4.17 / 275.38 6 76
7 8 -0.04 242 15.04 326 1187 5.35 / 276.56 6 135
Average= 7.90
(KJ/cycle)

Cycle 52 GMT 28/ 5/2023 7:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.52 35 15.04 445 234 0.23 / 266.11 6 29
2 7 2004.88 40 14.72 3107 1829 2.06 / 267.94 29 59
3 13 1910.44 20 14.70 3007 884 2.95 / 268.83 5 63
4 13 1275.36 20 14.77 2150 635 3.58 / 269.46 5 73
5 13 843.80 20 14.85 1554 462 4.04 / 269.92 5 82
6 13 47.48 20 15.10 399 120 4.16 / 270.04 6 77
7 8 -0.12 242 15.05 320 1165 5.33 / 271.21 6 131
Average= 7.98
(KJ/cycle)

Cycle 51 GMT 18/ 5/2023 10:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.32 35 15.03 451 237 0.24 / 260.70 6 28
2 7 2005.72 40 14.72 3135 1846 2.08 / 262.55 28 59
3 13 1919.24 20 14.70 3010 885 2.97 / 263.43 5 61
4 13 1488.72 20 14.73 2423 714 3.68 / 264.15 5 71
5 13 722.00 20 14.89 1374 409 4.09 / 264.55 5 80
6 13 157.92 20 15.06 564 170 4.26 / 264.72 5 76
7 8 0.00 242 15.05 317 1155 5.42 / 265.88 6 139
Average= 8.06
(KJ/cycle)

Cycle 50 GMT 8/ 5/2023 13:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.48 35 15.04 453 238 0.24 / 255.28 6 24
2 7 2011.96 40 14.72 3111 1832 2.07 / 257.12 24 56
3 13 1921.32 20 14.70 3042 894 2.96 / 258.01 5 64
4 13 1460.88 20 14.73 2400 707 3.67 / 258.72 5 69
5 13 769.72 20 14.88 1466 436 4.11 / 259.15 5 79
6 13 97.60 20 15.08 488 147 4.26 / 259.30 5 78
7 8 -0.12 242 15.05 319 1162 5.42 / 260.46 6 133
Average= 8.14
(KJ/cycle)

Cycle 49 GMT 28/ 4/2023 16:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.96 35 15.04 453 238 0.24 / 249.91 6 24
2 7 2005.76 40 14.72 3120 1837 2.08 / 251.74 24 59
3 13 1917.52 20 14.70 3020 888 2.96 / 252.63 5 64
4 13 1353.24 20 14.76 2247 663 3.63 / 253.29 5 70
5 13 793.76 20 14.88 1475 439 4.07 / 253.73 5 78
6 13 68.72 20 15.10 440 133 4.20 / 253.87 6 74
7 8 0.20 242 15.06 324 1181 5.38 / 255.05 6 132
Average= 8.23
(KJ/cycle)

Cycle 48 GMT 18/ 4/2023 19:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.04 35 15.05 445 234 0.23 / 244.53 6 22
2 7 2016.20 40 14.72 3127 1841 2.08 / 246.37 22 59
3 13 1923.72 20 14.71 2999 882 2.96 / 247.26 5 62
4 13 1274.20 20 14.78 2145 634 3.59 / 247.89 5 74
5 13 831.72 20 14.86 1545 459 4.05 / 248.35 5 80
6 13 73.96 20 15.10 450 136 4.19 / 248.49 6 75
7 8 -0.08 242 15.06 324 1181 5.37 / 249.67 6 132
Average= 8.32
(KJ/cycle)

Cycle 47 GMT 8/ 4/2023 22:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.40 35 15.07 443 234 0.23 / 239.23 6 23
2 7 2004.96 40 14.73 3113 1834 2.07 / 241.06 23 58
3 13 1915.36 20 14.72 2992 881 2.95 / 241.95 5 63
4 13 1272.08 20 14.79 2137 632 3.58 / 242.58 5 74
5 13 724.08 20 14.90 1399 417 4.00 / 242.99 5 83
6 13 52.20 20 15.11 414 125 4.12 / 243.12 5 75
7 13 13.44 20 15.11 347 105 4.23 / 243.22 6 71
8 8 0.00 223 15.06 320 1075 5.30 / 244.30 6 134
Average= 8.42
(KJ/cycle)

Cycle 46 GMT 30/ 3/2023 1:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.36 35 15.06 450 237 0.24 / 233.87 6 19
2 7 2007.76 40 14.73 3113 1834 2.07 / 235.70 19 58
3 13 1923.36 20 14.71 3037 893 2.96 / 236.60 5 63
4 13 1342.68 20 14.78 2237 661 3.63 / 237.26 5 72
5 13 878.88 20 14.86 1607 478 4.10 / 237.74 5 81
6 13 54.16 20 15.12 410 124 4.23 / 237.86 6 75
7 8 0.00 238 15.07 317 1137 5.36 / 239.00 6 132
Average= 8.54
(KJ/cycle)

Cycle 45 GMT 20/ 3/2023 4:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.36 35 15.07 460 243 0.24 / 228.43 6 19
2 7 2006.60 41 14.72 3119 1882 2.13 / 230.31 19 58
3 13 1917.12 20 14.72 3016 888 3.01 / 231.20 5 63
4 13 1368.76 20 14.77 2289 676 3.69 / 231.87 5 74
5 13 709.24 20 14.91 1383 412 4.10 / 232.29 5 81
6 13 143.60 20 15.08 558 168 4.27 / 232.45 5 81
7 8 0.00 242 15.07 323 1178 5.45 / 233.63 6 138
Average= 8.65
(KJ/cycle)

Cycle 44 GMT 10/ 3/2023 7:35: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.36 35 15.06 468 247 0.25 / 222.95 6 22
2 7 2003.48 40 14.73 3120 1838 2.08 / 224.79 59 59
3 13 1910.64 20 14.72 3009 886 2.97 / 225.68 5 64
4 13 1465.04 20 14.75 2401 708 3.68 / 226.38 5 70
5 13 804.16 20 14.89 1515 451 4.13 / 226.84 5 84
6 13 133.32 20 15.09 545 164 4.29 / 227.00 6 73
7 8 -0.04 244 15.08 322 1185 5.48 / 228.18 6 138
Average= 8.78
(KJ/cycle)

Cycle 43 GMT 28/ 2/2023 10:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.76 35 15.08 454 240 0.24 / 217.42 6 20
2 7 2005.36 40 14.74 3110 1834 2.07 / 219.26 20 58
3 13 1908.92 20 14.72 2982 878 2.95 / 220.14 5 63
4 13 1464.84 20 14.75 2410 711 3.66 / 220.85 5 71
5 13 794.84 20 14.89 1507 449 4.11 / 221.30 5 82
6 13 238.84 20 15.06 712 214 4.33 / 221.51 5 77
7 8 0.04 244 15.07 325 1195 5.52 / 222.70 6 134
Average= 8.91
(KJ/cycle)

Cycle 42 GMT 18/ 2/2023 13:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.36 35 15.08 439 232 0.23 / 212.15 6 20
2 7 2004.08 40 14.73 3097 1825 2.06 / 213.97 20 59
3 13 1907.80 20 14.72 2993 881 2.94 / 214.85 5 63
4 13 1358.24 20 14.79 2256 667 3.60 / 215.52 5 70
5 13 625.08 20 14.95 1255 375 3.98 / 215.90 5 85
6 13 49.56 20 15.13 409 124 4.10 / 216.02 6 72
7 8 -0.04 244 15.09 316 1163 5.27 / 217.18 6 140
Average= 9.05
(KJ/cycle)

Cycle 41 GMT 8/ 2/2023 16:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.84 35 15.07 445 235 0.23 / 206.81 6 21
2 7 2006.44 40 14.74 3112 1835 2.07 / 208.64 21 57
3 13 1920.56 20 14.72 3027 891 2.96 / 209.53 5 63
4 13 1391.96 20 14.78 2297 679 3.64 / 210.21 5 72
5 13 737.04 20 14.91 1421 424 4.06 / 210.64 5 84
6 13 90.56 20 15.12 469 142 4.21 / 210.78 6 76
7 8 -0.04 242 15.09 312 1139 5.34 / 211.92 6 136
Average= 9.21
(KJ/cycle)

Cycle 40 GMT 29/ 1/2023 19:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.64 35 15.07 471 248 0.25 / 201.32 6 21
2 7 2015.08 40 14.73 3124 1841 2.09 / 203.16 21 60
3 13 1921.76 20 14.72 3025 891 2.98 / 204.05 5 64
4 13 1348.76 20 14.79 2254 667 3.65 / 204.72 5 73
5 13 894.84 20 14.88 1628 484 4.13 / 205.21 5 79
6 13 199.84 20 15.08 633 191 4.32 / 205.40 5 76
7 13 15.32 20 15.13 354 107 4.43 / 205.50 6 72
8 8 -0.08 220 15.08 322 1068 5.50 / 206.57 6 134
Average= 9.39
(KJ/cycle)

Cycle 39 GMT 19/ 1/2023 22:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.92 35 15.08 474 250 0.25 / 195.86 6 22
2 7 2005.44 40 14.74 3105 1831 2.08 / 197.69 22 61
3 13 1909.80 20 14.73 3010 887 2.97 / 198.57 5 64
4 13 1346.80 20 14.79 2246 664 3.63 / 199.24 5 73
5 13 990.96 20 14.85 1761 523 4.16 / 199.76 5 79
6 13 47.68 20 15.14 406 123 4.28 / 199.88 6 71
7 8 -0.08 242 15.09 326 1190 5.47 / 201.08 6 131
Average= 9.58
(KJ/cycle)

Cycle 38 GMT 10/ 1/2023 1:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.96 35 15.08 460 243 0.24 / 190.41 6 22
2 7 2010.36 40 14.75 3122 1842 2.08 / 192.25 22 58
3 13 1919.36 20 14.73 3040 896 2.98 / 193.14 5 63
4 13 1284.72 20 14.81 2162 640 3.62 / 193.78 5 73
5 13 960.48 20 14.86 1726 513 4.13 / 194.30 5 81
6 13 46.24 20 15.15 403 122 4.26 / 194.42 6 67
7 8 -0.16 242 15.10 325 1188 5.44 / 195.61 6 130
Average= 9.78
(KJ/cycle)

Cycle 37 GMT 31/12/2022 4:35:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.52 35 15.09 466 246 0.25 / 184.99 6 24
2 7 2004.80 40 14.74 3145 1854 2.10 / 186.84 35 59
3 13 1909.00 20 14.73 3020 890 2.99 / 187.73 5 65
4 13 1361.12 20 14.79 2271 672 3.66 / 188.41 5 74
5 13 700.20 20 14.94 1374 411 4.07 / 188.82 5 83
6 13 36.92 20 15.15 394 119 4.19 / 188.94 6 67
7 8 0.00 244 15.10 333 1227 5.42 / 190.16 6 142
Average= 10.01
(KJ/cycle)

Cycle 36 GMT 21/12/2022 7:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.20 35 15.09 469 248 0.25 / 179.60 6 25
2 7 2005.00 40 14.75 3109 1834 2.08 / 181.44 25 59
3 13 1911.28 20 14.73 3023 891 2.97 / 182.33 5 64
4 13 1357.48 20 14.80 2264 670 3.64 / 183.00 5 74
5 13 704.60 20 14.95 1383 414 4.06 / 183.41 5 83
6 13 147.00 20 15.12 561 170 4.23 / 183.58 5 74
7 8 -0.08 242 15.10 319 1166 5.39 / 184.74 6 133
Average= 10.26
(KJ/cycle)

Cycle 35 GMT 11/12/2022 10:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.76 35 15.09 467 247 0.25 / 174.25 6 26
2 7 2003.80 40 14.75 3113 1837 2.08 / 176.08 26 59
3 13 1909.68 20 14.74 3004 886 2.97 / 176.97 5 63
4 13 1264.48 20 14.83 2145 636 3.61 / 177.61 5 74
5 13 826.96 20 14.91 1555 464 4.07 / 178.07 5 81
6 13 66.36 20 15.15 429 130 4.20 / 178.20 6 72
7 8 -0.04 240 15.11 318 1153 5.35 / 179.35 6 134
Average= 10.55
(KJ/cycle)

Cycle 34 GMT 1/12/2022 13:42:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.28 35 15.10 465 246 0.25 / 168.94 6 26
2 7 2010.44 40 14.75 3121 1841 2.09 / 170.78 26 59
3 13 1920.48 20 14.74 2995 883 2.97 / 171.66 5 64
4 13 1186.64 20 14.85 2034 604 3.57 / 172.26 5 75
5 13 762.76 20 14.93 1449 433 4.01 / 172.70 5 82
6 13 90.80 20 15.14 473 143 4.15 / 172.84 6 74
7 8 -0.04 240 15.11 320 1160 5.31 / 174.00 6 135
Average= 10.88
(KJ/cycle)

Cycle 33 GMT 21/11/2022 16:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.92 35 15.10 469 248 0.25 / 163.59 6 27
2 7 2006.16 40 14.76 3124 1844 2.09 / 165.44 27 60
3 13 1914.24 20 14.74 3013 888 2.98 / 166.32 5 62
4 13 1270.36 20 14.83 2145 636 3.62 / 166.96 5 73
5 13 634.20 20 14.98 1272 381 4.00 / 167.34 5 86
6 13 186.12 20 15.11 616 186 4.18 / 167.53 6 77
7 8 0.00 242 15.11 318 1163 5.35 / 168.69 6 134
Average= 11.25
(KJ/cycle)

Cycle 32 GMT 11/11/2022 19:30:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.44 35 15.10 456 241 0.24 / 158.13 6 29
2 7 2006.12 40 14.76 3108 1835 2.08 / 159.97 29 60
3 13 1913.24 20 14.74 3011 888 2.96 / 160.86 5 64
4 13 1469.04 20 14.78 2411 713 3.68 / 161.57 5 70
5 13 799.72 20 14.93 1513 452 4.13 / 162.02 5 83
6 13 55.76 20 15.16 420 127 4.26 / 162.15 6 70
7 8 0.00 242 15.12 327 1197 5.45 / 163.34 6 130
Average= 11.67
(KJ/cycle)

Cycle 31 GMT 1/11/2022 22:30:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.72 35 15.11 450 238 0.24 / 152.81 6 30
2 7 2007.08 40 14.76 3096 1828 2.07 / 154.64 30 59
3 13 1912.72 20 14.75 3006 887 2.95 / 155.52 5 64
4 13 1294.12 20 14.83 2173 645 3.60 / 156.17 5 73
5 13 749.08 20 14.95 1431 428 4.03 / 156.60 5 81
6 13 86.20 20 15.15 471 143 4.17 / 156.74 6 72
7 8 0.04 242 15.12 315 1153 5.32 / 157.89 6 137
Average= 12.15
(KJ/cycle)

Cycle 30 GMT 23/10/2022 1:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.00 35 15.11 453 240 0.24 / 147.54 6 29
2 7 2006.12 40 14.76 3119 1841 2.08 / 149.38 29 59
3 13 1914.44 20 14.75 2985 881 2.96 / 150.26 5 63
4 13 1267.80 20 14.84 2137 634 3.60 / 150.90 5 74
5 13 631.40 20 15.00 1245 373 3.97 / 151.27 5 79
6 13 92.48 20 15.16 471 143 4.11 / 151.41 6 71
7 8 0.12 242 15.13 316 1157 5.27 / 152.57 6 137
Average= 12.71
(KJ/cycle)

Cycle 29 GMT 13/10/2022 4: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.44 35 15.11 472 250 0.25 / 142.13 6 30
2 7 2013.16 40 14.77 3131 1850 2.10 / 143.98 33 59
3 13 1919.04 20 14.75 3034 895 2.99 / 144.88 5 66
4 13 1369.44 20 14.82 2269 673 3.67 / 145.55 5 72
5 13 828.40 20 14.93 1545 461 4.13 / 146.01 5 79
6 13 35.32 20 15.18 379 115 4.24 / 146.13 6 66
7 8 0.00 244 15.13 318 1174 5.42 / 147.30 6 132
Average= 13.39
(KJ/cycle)

Cycle 28 GMT 3/10/2022 7: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.24 35 15.12 467 247 0.25 / 136.77 6 30
2 3 1018.48 1 15.17 1812 27 0.27 / 136.79 5 56
3 7 2005.84 40 14.77 3134 1852 2.13 / 138.65 56 61
4 13 1913.92 20 14.76 3000 886 3.01 / 139.53 5 63
5 13 1267.60 20 14.85 2138 635 3.65 / 140.17 5 74
6 13 724.40 20 14.97 1389 416 4.06 / 140.58 5 81
7 13 76.20 20 15.17 441 134 4.20 / 140.72 6 69
8 8 0.04 242 15.14 319 1169 5.37 / 141.88 6 132
Average= 14.19
(KJ/cycle)

Cycle 27 GMT 23/ 9/2022 9:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.92 34 15.13 475 244 0.24 / 131.33 6 30
2 3 1018.56 1 15.16 1810 27 0.27 / 131.36 5 62
3 7 2008.76 40 14.77 3115 1840 2.11 / 133.20 62 59
4 13 1924.40 20 14.77 3020 892 3.00 / 134.09 5 62
5 13 1372.44 20 14.83 2274 674 3.68 / 134.77 5 72
6 13 808.84 20 14.95 1508 451 4.13 / 135.22 5 80
7 13 31.92 20 15.19 375 114 4.24 / 135.33 6 66
8 8 0.08 244 15.14 322 1190 5.43 / 136.52 6 131
Average= 15.17
(KJ/cycle)

Cycle 26 GMT 13/ 9/2022 12:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.08 34 15.12 467 240 0.24 / 126.12 6 32
2 7 2008.04 40 14.78 3111 1839 2.08 / 127.96 32 59
3 13 1812.84 20 14.79 2882 852 2.93 / 128.82 5 63
4 13 1251.48 20 14.86 2116 629 3.56 / 129.44 5 74
5 13 595.80 20 15.02 1214 365 3.93 / 129.81 5 82
6 8 0.16 261 15.15 323 1277 5.20 / 131.09 6 134
Average= 16.39
(KJ/cycle)

Cycle 25 GMT 3/ 9/2022 16: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.80 34 15.12 479 246 0.25 / 120.66 6 34
2 7 2003.80 40 14.78 3103 1834 2.08 / 122.50 34 60
3 13 1913.20 20 14.77 3016 891 2.97 / 123.39 5 62
4 13 1364.92 20 14.84 2271 674 3.65 / 124.06 5 71
5 13 906.40 20 14.92 1654 494 4.14 / 124.56 5 80
6 13 46.96 20 15.19 409 124 4.26 / 124.68 6 74
7 8 0.08 240 15.14 331 1203 5.47 / 125.88 6 133
Average= 17.98
(KJ/cycle)

Cycle 24 GMT 24/ 8/2022 19:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.04 34 15.12 486 250 0.25 / 115.26 6 32
2 7 2006.36 40 14.79 3100 1834 2.08 / 117.09 32 58
3 13 1910.80 20 14.78 2988 883 2.97 / 117.97 5 63
4 13 1357.52 20 14.85 2254 669 3.64 / 118.64 5 73
5 13 779.48 20 14.97 1476 442 4.08 / 119.08 5 82
6 13 48.08 20 15.19 418 127 4.21 / 119.21 6 76
7 8 0.00 238 15.14 335 1207 5.41 / 120.42 6 129
Average= 20.07
(KJ/cycle)

Cycle 23 GMT 14/ 8/2022 22:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.00 34 15.13 490 252 0.25 / 109.87 6 34
2 7 2006.20 40 14.79 3121 1846 2.10 / 111.71 34 58
3 13 1920.64 20 14.79 3005 889 2.99 / 112.60 5 63
4 13 1379.64 20 14.85 2294 681 3.67 / 113.28 5 71
5 13 632.12 20 15.02 1278 384 4.05 / 113.67 5 84
6 13 42.28 20 15.19 407 124 4.18 / 113.79 6 75
7 8 -0.04 240 15.14 334 1214 5.39 / 115.01 6 136
Average= 23.00
(KJ/cycle)

Cycle 22 GMT 5/ 8/2022 1:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.60 34 15.13 483 248 0.25 / 104.41 6 33
2 7 2013.04 40 14.79 3107 1838 2.09 / 106.25 33 58
3 13 1916.32 20 14.79 2985 883 2.97 / 107.13 5 63
4 13 1369.80 20 14.86 2281 678 3.65 / 107.81 5 71
5 13 801.36 20 14.97 1500 449 4.10 / 108.26 5 81
6 13 53.36 20 15.19 430 131 4.23 / 108.39 6 77
7 8 0.00 240 15.15 337 1225 5.45 / 109.62 6 131
Average= 27.40
(KJ/cycle)

Cycle 21 GMT 26/ 7/2022 4:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.56 34 15.13 483 248 0.25 / 98.99 6 34
2 7 2013.20 40 14.79 3116 1843 2.09 / 100.83 34 58
3 13 1919.48 20 14.79 2996 886 2.98 / 101.72 5 61
4 13 1267.72 20 14.88 2149 640 3.62 / 102.36 5 74
5 13 719.36 20 14.99 1392 417 4.03 / 102.78 5 80
6 13 74.40 20 15.19 460 140 4.17 / 102.92 5 76
7 8 -0.04 242 15.15 340 1247 5.42 / 104.16 6 135
Average= 34.72
(KJ/cycle)

Cycle 20 GMT 16/ 7/2022 7: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.24 34 15.15 476 245 0.25 / 93.59 6 28
2 7 2006.68 41 14.79 3122 1893 2.14 / 95.48 28 60
3 13 1915.56 20 14.79 3020 893 3.03 / 96.38 5 63
4 13 1264.28 20 14.89 2135 636 3.67 / 97.01 5 73
5 13 606.36 20 15.03 1244 374 4.04 / 97.39 5 83
6 13 79.04 20 15.19 463 141 4.18 / 97.53 6 76
7 8 -0.08 240 15.15 334 1214 5.40 / 98.74 6 140
Average= 49.37
(KJ/cycle)

Cycle 19 GMT 6/ 7/2022 10: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.20 34 15.14 479 247 0.25 / 88.34 6 30
2 7 2010.72 40 14.80 3133 1855 2.10 / 90.19 30 58
3 13 1816.00 20 14.82 2871 851 2.95 / 91.04 5 65
4 13 1191.36 20 14.91 2035 607 3.56 / 91.65 5 74
5 13 661.20 20 15.02 1313 394 3.95 / 92.04 5 81
6 13 50.24 20 15.21 415 126 4.08 / 92.17 6 75
7 8 0.08 238 15.16 326 1176 5.26 / 93.35 6 131
Average= 93.35
(KJ/cycle)

Cycle 17 GMT 16/ 6/2022 15:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.68 34 15.16 474 244 0.24 / 82.90 6 26
2 7 2007.48 40 14.81 3098 1835 2.08 / 84.74 26 58
3 13 1923.80 20 14.81 3000 889 2.97 / 85.63 5 62
4 13 1368.36 20 14.87 2278 677 3.65 / 86.30 5 74
5 13 816.32 20 14.98 1533 459 4.10 / 86.76 5 80
6 13 39.16 20 15.22 399 121 4.23 / 86.88 6 72
7 8 0.00 240 15.17 331 1205 5.43 / 88.09 6 130
Average= 4.89
(KJ/cycle)

Cycle 16 GMT 6/ 6/2022 18:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.96 34 15.15 473 244 0.24 / 77.58 6 26
2 7 2004.08 40 14.81 3122 1849 2.09 / 79.43 26 58
3 13 1808.04 20 14.84 2860 849 2.94 / 80.28 5 64
4 13 1264.04 20 14.90 2141 638 3.58 / 80.91 5 75
5 13 729.72 20 15.01 1402 421 4.00 / 81.33 5 81
6 13 44.24 20 15.22 412 125 4.13 / 81.46 6 73
7 8 -0.04 240 15.17 329 1198 5.32 / 82.66 6 132
Average= 4.86
(KJ/cycle)

Cycle 15 GMT 27/ 5/2022 21:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.72 34 15.16 470 242 0.24 / 72.16 6 25
2 7 2009.64 40 14.82 3120 1850 2.09 / 74.01 25 59
3 13 1920.12 20 14.82 3007 891 2.98 / 74.90 5 64
4 13 1282.80 20 14.90 2163 645 3.63 / 75.55 5 73
5 13 751.12 20 15.01 1432 430 4.06 / 75.98 5 80
6 13 93.28 20 15.21 483 147 4.20 / 76.13 6 74
7 8 0.04 242 15.17 329 1208 5.41 / 77.33 6 132
Average= 4.83
(KJ/cycle)

Cycle 14 GMT 18/ 5/2022 0:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.36 34 15.16 476 245 0.25 / 66.79 6 26
2 7 2004.44 40 14.82 3122 1851 2.10 / 68.64 26 61
3 13 1910.20 20 14.82 2989 886 2.98 / 69.53 5 64
4 13 1256.60 20 14.91 2125 634 3.62 / 70.16 5 75
5 13 623.52 20 15.05 1275 384 4.00 / 70.55 5 85
6 13 38.08 20 15.23 403 123 4.12 / 70.67 6 73
7 8 -0.20 242 15.17 341 1252 5.37 / 71.92 6 138
Average= 4.79
(KJ/cycle)

Cycle 13 GMT 8/ 5/2022 3:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.20 34 15.17 462 238 0.24 / 61.29 6 24
2 7 2007.64 41 14.82 3106 1887 2.13 / 63.17 24 59
3 13 1914.28 20 14.83 2989 887 3.01 / 64.06 5 62
4 13 1358.36 20 14.89 2262 674 3.69 / 64.73 5 72
5 13 787.16 20 15.01 1484 445 4.13 / 65.18 5 81
6 13 102.28 20 15.21 498 151 4.28 / 65.33 5 77
7 8 0.04 242 15.18 331 1216 5.50 / 66.55 6 137
Average= 4.75
(KJ/cycle)

Cycle 12 GMT 28/ 4/2022 6:17: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.80 34 15.17 471 243 0.24 / 55.89 6 23
2 7 2010.04 40 14.83 3114 1847 2.09 / 57.74 23 60
3 13 1924.76 20 14.83 3004 891 2.98 / 58.63 5 64
4 13 1270.92 20 14.91 2151 641 3.62 / 59.27 5 75
5 13 832.60 20 14.99 1565 469 4.09 / 59.74 5 83
6 13 19.00 20 15.24 370 113 4.20 / 59.85 6 71
7 8 -0.04 240 15.18 329 1199 5.40 / 61.05 6 133
Average= 4.70
(KJ/cycle)

Cycle 11 GMT 18/ 4/2022 9:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.32 34 15.18 454 234 0.23 / 50.37 6 24
2 3 1021.20 1 15.20 1836 28 0.26 / 50.40 5 47
3 7 2003.28 40 14.84 3105 1843 2.11 / 52.24 47 63
4 13 1905.36 20 14.84 3006 892 3.00 / 53.14 5 65
5 13 1355.40 20 14.90 2254 672 3.67 / 53.81 5 73
6 13 802.64 20 15.01 1512 454 4.12 / 54.26 5 82
7 13 55.96 20 15.23 433 132 4.26 / 54.39 6 74
8 8 0.04 244 15.18 338 1252 5.51 / 55.65 6 138
Average= 4.64
(KJ/cycle)

Cycle 10 GMT 8/ 4/2022 12:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.60 34 15.17 459 237 0.24 / 44.99 6 20
2 7 2005.88 40 14.83 3128 1856 2.09 / 46.84 20 60
3 13 1910.92 20 14.83 2997 889 2.98 / 47.73 5 64
4 13 1349.28 20 14.90 2260 673 3.65 / 48.40 5 74
5 13 655.64 20 15.05 1320 397 4.05 / 48.80 5 86
6 13 44.80 20 15.23 409 125 4.18 / 48.93 6 75
7 8 0.00 242 15.19 330 1213 5.39 / 50.14 6 143
Average= 4.56
(KJ/cycle)

Cycle 9 GMT 29/ 3/2022 15:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.60 34 15.18 462 238 0.24 / 39.71 6 20
2 7 2014.80 40 14.84 3132 1859 2.10 / 41.57 20 60
3 13 1707.04 20 14.87 2748 817 2.91 / 42.39 5 67
4 13 1183.20 20 14.94 2041 610 3.52 / 43.00 5 76
5 13 650.68 20 15.05 1310 394 3.92 / 43.40 5 84
6 13 45.56 20 15.23 417 127 4.05 / 43.52 5 76
7 8 -0.08 242 15.18 334 1227 5.27 / 44.75 6 132
Average= 4.47
(KJ/cycle)

Cycle 8 GMT 19/ 3/2022 18:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.92 34 15.17 465 240 0.24 / 34.42 6 23
2 7 2016.16 40 14.84 3134 1860 2.10 / 36.28 23 62
3 13 1722.08 20 14.88 2741 816 2.92 / 37.10 5 68
4 13 1200.28 20 14.94 2055 614 3.53 / 37.71 5 75
5 13 664.68 20 15.05 1324 399 3.93 / 38.11 5 83
6 13 57.56 20 15.23 433 132 4.06 / 38.24 6 76
7 8 -0.04 242 15.19 336 1235 5.30 / 39.48 6 131
Average= 4.39
(KJ/cycle)

Cycle 7 GMT 9/ 3/2022 21: 5: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.96 33 15.18 461 231 0.23 / 29.03 6 22
2 7 2013.72 41 14.84 3140 1911 2.14 / 30.94 22 62
3 13 1815.80 20 14.86 2898 861 3.00 / 31.81 5 67
4 13 1267.68 20 14.93 2153 643 3.65 / 32.45 5 74
5 13 594.80 20 15.07 1230 371 4.02 / 32.82 5 83
6 13 38.76 20 15.24 411 125 4.14 / 32.94 6 74
7 8 0.00 240 15.19 339 1236 5.38 / 34.18 6 134
Average= 4.27
(KJ/cycle)

Cycle 6 GMT 28/ 2/2022 0: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.80 33 15.19 451 226 0.23 / 23.72 6 21
2 7 2004.68 40 14.85 3131 1860 2.09 / 25.58 6 63
3 13 1908.80 20 14.85 3027 899 2.98 / 26.48 5 66
4 13 1149.56 20 14.96 1987 595 3.58 / 27.08 5 76
5 13 616.80 20 15.07 1249 376 3.96 / 27.45 5 82
6 13 34.60 20 15.24 402 123 4.08 / 27.58 6 74
7 8 -0.08 244 15.19 331 1227 5.31 / 28.80 6 136
Average= 4.11
(KJ/cycle)

Cycle 5 GMT 18/ 2/2022 2:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.96 31 15.19 464 218 0.22 / 18.33 6 22
2 10 1026.72 3 15.14 1834 83 0.30 / 18.41 5 58
3 7 2010.24 40 14.86 3113 1850 2.15 / 20.26 58 61
4 13 1918.40 20 14.85 3003 892 3.04 / 21.16 5 64
5 13 1251.84 20 14.95 2102 628 3.67 / 21.78 5 74
6 13 704.96 20 15.05 1343 404 4.08 / 22.19 5 80
7 13 39.60 20 15.25 394 120 4.20 / 22.31 6 72
8 8 -0.04 246 15.20 318 1189 5.39 / 23.50 6 133
Average= 3.92
(KJ/cycle)

Cycle 4 GMT 8/ 2/2022 5:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.92 33 15.19 458 230 0.23 / 13.79 6 22
2 7 1509.20 40 15.02 2416 1452 1.68 / 15.24 22 67
3 13 1443.72 20 15.00 2364 709 2.39 / 15.95 5 70
4 13 1037.88 20 15.03 1824 548 2.94 / 16.50 5 76
5 13 415.04 20 15.16 948 287 3.23 / 16.79 5 81
6 13 38.40 20 15.26 401 122 3.35 / 16.91 5 73
7 8 0.04 240 15.21 329 1201 4.55 / 18.11 6 130
Average= 3.62
(KJ/cycle)

Cycle 3 GMT 6/ 2/2022 19:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.56 32 15.18 464 225 0.23 / 9.18 6 21
2 3 1021.36 1 15.23 1828 28 0.25 / 9.21 5 8
3 7 1515.00 40 15.01 2429 1458 1.71 / 10.67 8 67
4 13 1445.04 20 15.00 2370 711 2.42 / 11.38 5 70
5 13 1137.12 20 15.01 1930 579 3.00 / 11.96 5 75
6 13 487.52 20 15.14 1053 319 3.32 / 12.28 5 83
7 13 28.52 20 15.26 378 115 3.44 / 12.40 6 73
8 8 -0.04 242 15.21 317 1167 4.60 / 13.56 6 137
Average= 3.39
(KJ/cycle)

Cycle 2 GMT 5/ 2/2022 9:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.36 31 15.23 445 210 0.21 / 4.70 6 22
2 3 1050.56 1 15.20 1894 29 0.24 / 4.73 5 32
3 7 1515.80 40 15.02 2438 1465 1.70 / 6.20 32 67
4 13 1437.64 20 15.00 2328 698 2.40 / 6.90 5 70
5 13 941.40 20 15.05 1692 509 2.91 / 7.41 5 78
6 13 421.72 20 15.16 960 291 3.20 / 7.70 5 82
7 13 21.56 20 15.26 362 110 3.31 / 7.81 6 72
8 8 -0.08 242 15.21 313 1152 4.46 / 8.96 6 131
Average= 2.99
(KJ/cycle)

Cycle 1 GMT 3/ 2/2022 23: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.80 31 15.46 408 196 0.20 / 1.79 6 15
2 10 1014.44 3 15.24 1782 81 0.28 / 1.88 5 48
3 3 964.16 -1 15.58 7 0 0.08 / 1.88 5 48
4 7 999.40 40 15.14 1704 1032 1.31 / 2.91 48 70
5 13 567.32 20 15.21 1156 352 1.66 / 3.26 5 80
6 13 29.84 20 15.33 367 113 1.77 / 3.37 6 71
7 8 0.08 244 15.28 301 1122 2.90 / 4.49 6 140
Average= 2.25
(KJ/cycle)

Cycle 0 GMT 3/ 2/2022 12:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 139.96 30 15.62 443 208 0.21 / 0.21 6 15
2 7 151.28 40 15.59 454 283 0.49 / 0.49 15 20
3 13 84.92 20 15.59 363 113 0.60 / 0.60 6 25
4 8 0.16 267 15.53 240 995 1.60 / 1.60 6 -99
Average= 1.60