SIO Argo Site:
|
![]() |
![]() |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.20 | 34 | 14.85 | 595 | 300 | 0.30 / 715.25 | 5 | 18 |
2 | 3 | 1020.24 | 1 | 14.98 | 2090 | 31 | 0.33 / 715.28 | 5 | 64 |
3 | 7 | 2008.96 | 40 | 14.35 | 3577 | 2053 | 2.38 / 717.33 | 64 | 59 |
4 | 13 | 1934.48 | 20 | 14.33 | 3477 | 997 | 3.38 / 718.33 | 5 | 63 |
5 | 13 | 1307.52 | 20 | 14.43 | 2502 | 722 | 4.10 / 719.05 | 5 | 73 |
6 | 13 | 768.72 | 20 | 14.59 | 1673 | 488 | 4.59 / 719.54 | 5 | 83 |
7 | 13 | 210.08 | 20 | 14.81 | 812 | 241 | 4.83 / 719.78 | 5 | 81 |
8 | 13 | 23.88 | 20 | 14.89 | 498 | 148 | 4.98 / 719.93 | 5 | 71 |
9 | 8 | -0.12 | 214 | 14.82 | 445 | 1411 | 6.39 / 721.34 | 5 | 134 |
Average= | 7.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.72 | 34 | 14.85 | 591 | 298 | 0.30 / 708.93 | 5 | 15 |
2 | 7 | 2015.92 | 40 | 14.35 | 3576 | 2053 | 2.35 / 710.98 | 15 | 59 |
3 | 13 | 1931.56 | 20 | 14.34 | 3448 | 989 | 3.34 / 711.97 | 5 | 63 |
4 | 13 | 1398.32 | 20 | 14.41 | 2643 | 762 | 4.10 / 712.73 | 5 | 73 |
5 | 13 | 657.88 | 20 | 14.65 | 1496 | 438 | 4.54 / 713.17 | 5 | 81 |
6 | 13 | 114.84 | 20 | 14.86 | 661 | 196 | 4.74 / 713.37 | 5 | 79 |
7 | 13 | 30.28 | 20 | 14.90 | 510 | 152 | 4.89 / 713.52 | 5 | 71 |
8 | 8 | -0.12 | 214 | 14.83 | 450 | 1428 | 6.32 / 714.95 | 5 | 139 |
Average= | 7.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.76 | 34 | 14.84 | 588 | 297 | 0.30 / 702.52 | 5 | 19 |
2 | 7 | 2018.56 | 40 | 14.34 | 3596 | 2063 | 2.36 / 704.58 | 19 | 59 |
3 | 13 | 1939.84 | 20 | 14.34 | 3479 | 998 | 3.36 / 705.58 | 5 | 61 |
4 | 13 | 1384.68 | 20 | 14.41 | 2624 | 756 | 4.11 / 706.33 | 5 | 73 |
5 | 13 | 933.68 | 20 | 14.53 | 1925 | 559 | 4.67 / 706.89 | 5 | 80 |
6 | 13 | 107.12 | 20 | 14.86 | 650 | 193 | 4.87 / 707.08 | 5 | 82 |
7 | 8 | -0.16 | 232 | 14.83 | 450 | 1548 | 6.41 / 708.63 | 5 | 131 |
Average= | 7.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.88 | 34 | 14.84 | 593 | 299 | 0.30 / 696.10 | 5 | 19 |
2 | 7 | 2008.08 | 40 | 14.35 | 3568 | 2048 | 2.35 / 698.15 | 19 | 58 |
3 | 13 | 1830.16 | 20 | 14.36 | 3309 | 950 | 3.30 / 699.10 | 5 | 64 |
4 | 13 | 1509.96 | 20 | 14.37 | 2823 | 811 | 4.11 / 699.91 | 5 | 71 |
5 | 13 | 911.84 | 20 | 14.54 | 1890 | 550 | 4.66 / 700.46 | 5 | 79 |
6 | 13 | 51.64 | 20 | 14.90 | 552 | 164 | 4.82 / 700.62 | 5 | 74 |
7 | 13 | 33.96 | 20 | 14.89 | 523 | 156 | 4.98 / 700.78 | 5 | 74 |
8 | 8 | -0.04 | 214 | 14.83 | 454 | 1441 | 6.42 / 702.22 | 5 | 139 |
Average= | 7.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.64 | 35 | 14.83 | 583 | 303 | 0.30 / 689.85 | 5 | 18 |
2 | 7 | 2008.20 | 40 | 14.36 | 3560 | 2045 | 2.35 / 691.90 | 18 | 58 |
3 | 13 | 1916.64 | 20 | 14.35 | 3429 | 984 | 3.33 / 692.88 | 5 | 62 |
4 | 13 | 1300.56 | 20 | 14.45 | 2491 | 720 | 4.05 / 693.60 | 5 | 74 |
5 | 13 | 771.20 | 20 | 14.60 | 1678 | 490 | 4.54 / 694.09 | 5 | 79 |
6 | 13 | 51.48 | 20 | 14.89 | 548 | 163 | 4.70 / 694.26 | 5 | 78 |
7 | 13 | 15.60 | 20 | 14.90 | 488 | 145 | 4.85 / 694.40 | 5 | 76 |
8 | 8 | -0.40 | 210 | 14.82 | 449 | 1397 | 6.25 / 695.80 | 5 | 135 |
Average= | 7.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.96 | 34 | 14.83 | 585 | 295 | 0.29 / 683.49 | 5 | 17 |
2 | 7 | 2008.44 | 40 | 14.36 | 3571 | 2051 | 2.35 / 685.54 | 17 | 59 |
3 | 13 | 1924.68 | 20 | 14.35 | 3439 | 987 | 3.33 / 686.53 | 5 | 61 |
4 | 13 | 1364.32 | 20 | 14.42 | 2595 | 748 | 4.08 / 687.27 | 5 | 74 |
5 | 13 | 747.88 | 20 | 14.61 | 1643 | 480 | 4.56 / 687.75 | 5 | 82 |
6 | 13 | 174.72 | 20 | 14.83 | 758 | 225 | 4.79 / 687.98 | 5 | 81 |
7 | 13 | 35.72 | 20 | 14.89 | 530 | 158 | 4.94 / 688.14 | 5 | 79 |
8 | 8 | -0.32 | 208 | 14.82 | 459 | 1415 | 6.36 / 689.55 | 5 | 129 |
Average= | 7.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.04 | 34 | 14.85 | 575 | 290 | 0.29 / 677.21 | 5 | 14 |
2 | 7 | 2013.16 | 41 | 14.35 | 3578 | 2105 | 2.40 / 679.32 | 14 | 58 |
3 | 13 | 1817.96 | 20 | 14.37 | 3274 | 941 | 3.34 / 680.26 | 5 | 64 |
4 | 13 | 1269.52 | 20 | 14.46 | 2440 | 706 | 4.04 / 680.96 | 5 | 74 |
5 | 13 | 831.88 | 20 | 14.57 | 1772 | 516 | 4.56 / 681.48 | 5 | 80 |
6 | 13 | 43.32 | 20 | 14.90 | 532 | 159 | 4.72 / 681.64 | 5 | 74 |
7 | 13 | 14.88 | 20 | 14.90 | 482 | 144 | 4.86 / 681.78 | 5 | 71 |
8 | 8 | -0.20 | 212 | 14.83 | 449 | 1412 | 6.27 / 683.19 | 5 | 132 |
Average= | 7.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.80 | 34 | 14.85 | 589 | 297 | 0.30 / 670.84 | 5 | 17 |
2 | 7 | 2004.56 | 40 | 14.36 | 3558 | 2044 | 2.34 / 672.88 | 17 | 56 |
3 | 13 | 1915.68 | 20 | 14.35 | 3425 | 983 | 3.32 / 673.86 | 5 | 62 |
4 | 13 | 1499.60 | 20 | 14.39 | 2798 | 805 | 4.13 / 674.67 | 5 | 71 |
5 | 13 | 731.64 | 20 | 14.62 | 1620 | 474 | 4.60 / 675.14 | 5 | 82 |
6 | 13 | 155.04 | 20 | 14.84 | 730 | 217 | 4.82 / 675.36 | 5 | 82 |
7 | 13 | 35.00 | 20 | 14.89 | 527 | 157 | 4.98 / 675.52 | 5 | 75 |
8 | 8 | -0.28 | 210 | 14.82 | 451 | 1404 | 6.38 / 676.92 | 5 | 136 |
Average= | 7.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.96 | 34 | 14.86 | 604 | 305 | 0.31 / 664.75 | 5 | 15 |
2 | 7 | 2004.32 | 40 | 14.36 | 3563 | 2047 | 2.35 / 666.80 | 15 | 58 |
3 | 13 | 1798.16 | 20 | 14.38 | 3236 | 931 | 3.28 / 667.73 | 5 | 64 |
4 | 13 | 1165.72 | 20 | 14.50 | 2266 | 657 | 3.94 / 668.38 | 5 | 75 |
5 | 13 | 637.88 | 20 | 14.66 | 1448 | 425 | 4.36 / 668.81 | 5 | 84 |
6 | 13 | 64.52 | 20 | 14.89 | 568 | 169 | 4.53 / 668.98 | 5 | 75 |
7 | 13 | 37.56 | 20 | 14.89 | 525 | 156 | 4.69 / 669.13 | 5 | 74 |
8 | 8 | -0.08 | 212 | 14.84 | 447 | 1406 | 6.10 / 670.54 | 5 | 129 |
Average= | 7.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.48 | 34 | 14.85 | 570 | 288 | 0.29 / 658.35 | 5 | 15 |
2 | 7 | 2006.20 | 40 | 14.36 | 3561 | 2045 | 2.33 / 660.39 | 15 | 58 |
3 | 13 | 1915.36 | 20 | 14.35 | 3425 | 983 | 3.32 / 661.37 | 5 | 62 |
4 | 13 | 1484.84 | 20 | 14.39 | 2769 | 797 | 4.11 / 662.17 | 5 | 71 |
5 | 13 | 810.64 | 20 | 14.58 | 1744 | 509 | 4.62 / 662.68 | 5 | 80 |
6 | 13 | 69.44 | 20 | 14.89 | 580 | 173 | 4.79 / 662.85 | 5 | 78 |
7 | 13 | 40.08 | 20 | 14.89 | 537 | 160 | 4.95 / 663.01 | 5 | 77 |
8 | 8 | -0.08 | 214 | 14.84 | 451 | 1432 | 6.39 / 664.44 | 5 | 138 |
Average= | 7.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.84 | 34 | 14.86 | 552 | 279 | 0.28 / 652.05 | 5 | 17 |
2 | 7 | 2010.44 | 41 | 14.35 | 3561 | 2095 | 2.37 / 654.15 | 17 | 59 |
3 | 13 | 1914.76 | 20 | 14.34 | 3422 | 981 | 3.36 / 655.13 | 5 | 63 |
4 | 13 | 1375.32 | 20 | 14.43 | 2608 | 753 | 4.11 / 655.88 | 5 | 72 |
5 | 13 | 689.08 | 20 | 14.64 | 1544 | 452 | 4.56 / 656.33 | 5 | 83 |
6 | 13 | 64.56 | 20 | 14.89 | 561 | 167 | 4.73 / 656.50 | 5 | 80 |
7 | 13 | 37.12 | 20 | 14.89 | 520 | 155 | 4.88 / 656.66 | 5 | 79 |
8 | 8 | -0.28 | 212 | 14.83 | 446 | 1402 | 6.28 / 658.06 | 5 | 136 |
Average= | 7.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.44 | 34 | 14.85 | 570 | 288 | 0.29 / 645.44 | 5 | 14 |
2 | 7 | 2014.56 | 40 | 14.35 | 3590 | 2061 | 2.35 / 647.50 | 14 | 58 |
3 | 13 | 1920.56 | 20 | 14.35 | 3450 | 990 | 3.34 / 648.49 | 5 | 62 |
4 | 13 | 1713.28 | 20 | 14.33 | 3129 | 897 | 4.24 / 649.39 | 5 | 65 |
5 | 13 | 902.68 | 20 | 14.56 | 1888 | 550 | 4.79 / 649.94 | 5 | 78 |
6 | 13 | 325.60 | 20 | 14.78 | 998 | 295 | 5.08 / 650.24 | 5 | 84 |
7 | 13 | 24.12 | 20 | 14.91 | 490 | 146 | 5.23 / 650.38 | 5 | 72 |
8 | 8 | -0.04 | 214 | 14.84 | 438 | 1391 | 6.62 / 651.77 | 5 | 129 |
Average= | 7.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.68 | 34 | 14.86 | 563 | 284 | 0.28 / 639.08 | 5 | 17 |
2 | 7 | 2007.24 | 40 | 14.35 | 3579 | 2054 | 2.34 / 641.14 | 17 | 58 |
3 | 13 | 1917.76 | 20 | 14.35 | 3435 | 986 | 3.32 / 642.12 | 5 | 65 |
4 | 13 | 1351.96 | 20 | 14.44 | 2575 | 744 | 4.07 / 642.87 | 5 | 72 |
5 | 13 | 794.52 | 20 | 14.60 | 1708 | 499 | 4.57 / 643.36 | 5 | 79 |
6 | 13 | 103.64 | 20 | 14.88 | 632 | 188 | 4.76 / 643.55 | 5 | 76 |
7 | 13 | 54.48 | 20 | 14.89 | 552 | 164 | 4.92 / 643.72 | 5 | 81 |
8 | 13 | 15.88 | 20 | 14.90 | 476 | 142 | 5.06 / 643.86 | 5 | 72 |
9 | 8 | -0.28 | 193 | 14.83 | 438 | 1254 | 6.31 / 645.11 | 5 | 136 |
10 | 14 | -0.28 | 7 | 14.78 | 424 | 44 | 6.36 / 645.16 | 55 | 218 |
Average= | 7.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.08 | 34 | 14.85 | 580 | 293 | 0.29 / 632.59 | 5 | 14 |
2 | 7 | 2009.20 | 40 | 14.36 | 3557 | 2043 | 2.34 / 634.64 | 14 | 58 |
3 | 13 | 1915.88 | 20 | 14.36 | 3418 | 982 | 3.32 / 635.62 | 5 | 62 |
4 | 13 | 1259.80 | 20 | 14.48 | 2430 | 704 | 4.02 / 636.32 | 5 | 73 |
5 | 13 | 965.04 | 20 | 14.53 | 1966 | 571 | 4.59 / 636.89 | 5 | 78 |
6 | 13 | 353.28 | 20 | 14.76 | 1043 | 308 | 4.90 / 637.20 | 5 | 84 |
7 | 13 | 51.72 | 20 | 14.88 | 540 | 161 | 5.06 / 637.36 | 5 | 77 |
8 | 13 | 17.84 | 20 | 14.89 | 481 | 143 | 5.20 / 637.50 | 5 | 73 |
9 | 8 | -0.08 | 197 | 14.83 | 436 | 1274 | 6.48 / 638.78 | 5 | 142 |
10 | 14 | -0.08 | 3 | 14.79 | 424 | 19 | 6.50 / 638.80 | 63 | 155 |
Average= | 7.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.96 | 34 | 14.87 | 568 | 287 | 0.29 / 626.20 | 5 | 14 |
2 | 7 | 2006.80 | 40 | 14.36 | 3556 | 2043 | 2.33 / 628.24 | 14 | 57 |
3 | 13 | 1805.40 | 20 | 14.38 | 3255 | 936 | 3.27 / 629.17 | 5 | 65 |
4 | 13 | 1600.28 | 20 | 14.36 | 2946 | 846 | 4.11 / 630.02 | 5 | 69 |
5 | 13 | 891.88 | 20 | 14.56 | 1861 | 542 | 4.65 / 630.56 | 5 | 79 |
6 | 13 | 98.92 | 20 | 14.88 | 620 | 185 | 4.84 / 630.75 | 5 | 80 |
7 | 13 | 24.44 | 20 | 14.91 | 501 | 149 | 4.99 / 630.90 | 5 | 75 |
8 | 8 | -0.08 | 214 | 14.84 | 442 | 1404 | 6.39 / 632.30 | 5 | 141 |
Average= | 7.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.92 | 34 | 14.85 | 574 | 290 | 0.29 / 619.81 | 5 | 18 |
2 | 7 | 2013.16 | 40 | 14.36 | 3565 | 2048 | 2.34 / 621.86 | 18 | 58 |
3 | 13 | 1924.12 | 20 | 14.35 | 3434 | 986 | 3.32 / 622.84 | 5 | 63 |
4 | 13 | 1482.20 | 20 | 14.40 | 2769 | 797 | 4.12 / 623.64 | 5 | 72 |
5 | 13 | 922.20 | 20 | 14.55 | 1911 | 556 | 4.68 / 624.20 | 5 | 78 |
6 | 13 | 71.92 | 20 | 14.90 | 581 | 173 | 4.85 / 624.37 | 5 | 77 |
7 | 13 | 40.16 | 20 | 14.90 | 526 | 157 | 5.01 / 624.53 | 5 | 76 |
8 | 8 | -0.04 | 214 | 14.85 | 435 | 1382 | 6.39 / 625.91 | 5 | 138 |
Average= | 7.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.44 | 34 | 14.87 | 556 | 281 | 0.28 / 613.54 | 5 | 16 |
2 | 7 | 2012.20 | 40 | 14.36 | 3571 | 2051 | 2.33 / 615.59 | 16 | 58 |
3 | 13 | 1710.92 | 20 | 14.40 | 3124 | 900 | 3.23 / 616.49 | 5 | 67 |
4 | 13 | 1312.48 | 20 | 14.44 | 2521 | 728 | 3.96 / 617.22 | 5 | 74 |
5 | 13 | 971.36 | 20 | 14.52 | 1992 | 578 | 4.54 / 617.80 | 5 | 77 |
6 | 13 | 71.88 | 20 | 14.89 | 585 | 174 | 4.71 / 617.97 | 5 | 79 |
7 | 13 | 17.36 | 20 | 14.91 | 491 | 146 | 4.86 / 618.12 | 5 | 75 |
8 | 8 | -0.12 | 212 | 14.83 | 446 | 1402 | 6.26 / 619.52 | 5 | 138 |
Average= | 7.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.00 | 34 | 14.87 | 557 | 282 | 0.28 / 607.35 | 5 | 17 |
2 | 7 | 2006.92 | 40 | 14.37 | 3553 | 2042 | 2.32 / 609.39 | 17 | 58 |
3 | 13 | 1908.92 | 20 | 14.37 | 3405 | 979 | 3.30 / 610.37 | 5 | 62 |
4 | 13 | 1229.12 | 20 | 14.49 | 2380 | 690 | 3.99 / 611.06 | 5 | 73 |
5 | 13 | 790.16 | 20 | 14.61 | 1702 | 497 | 4.49 / 611.56 | 5 | 83 |
6 | 13 | 54.20 | 20 | 14.91 | 545 | 163 | 4.65 / 611.72 | 5 | 79 |
7 | 13 | 32.08 | 20 | 14.90 | 515 | 153 | 4.81 / 611.87 | 5 | 78 |
8 | 8 | -0.24 | 210 | 14.84 | 444 | 1384 | 6.19 / 613.26 | 5 | 131 |
Average= | 7.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.04 | 33 | 14.87 | 550 | 270 | 0.27 / 601.06 | 5 | 15 |
2 | 3 | 1024.48 | 1 | 14.98 | 2094 | 31 | 0.30 / 601.09 | 5 | 62 |
3 | 7 | 2004.52 | 41 | 14.36 | 3544 | 2087 | 2.39 / 603.18 | 62 | 57 |
4 | 13 | 1906.80 | 20 | 14.37 | 3406 | 979 | 3.37 / 604.16 | 5 | 62 |
5 | 13 | 1375.08 | 20 | 14.44 | 2595 | 749 | 4.12 / 604.91 | 5 | 72 |
6 | 13 | 723.88 | 20 | 14.64 | 1598 | 468 | 4.58 / 605.37 | 5 | 83 |
7 | 13 | 81.44 | 20 | 14.90 | 585 | 174 | 4.76 / 605.55 | 5 | 80 |
8 | 13 | 46.28 | 20 | 14.90 | 526 | 157 | 4.92 / 605.71 | 5 | 78 |
9 | 8 | -0.12 | 214 | 14.85 | 429 | 1363 | 6.28 / 607.07 | 5 | 148 |
Average= | 7.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.28 | 34 | 14.86 | 552 | 279 | 0.28 / 594.70 | 5 | 16 |
2 | 7 | 2004.76 | 40 | 14.38 | 3533 | 2032 | 2.31 / 596.73 | 16 | 58 |
3 | 13 | 1929.40 | 20 | 14.36 | 3434 | 986 | 3.30 / 597.71 | 5 | 62 |
4 | 13 | 1470.92 | 20 | 14.41 | 2743 | 791 | 4.09 / 598.51 | 5 | 70 |
5 | 13 | 1004.28 | 20 | 14.53 | 2019 | 587 | 4.67 / 599.09 | 5 | 78 |
6 | 13 | 87.60 | 20 | 14.90 | 595 | 177 | 4.85 / 599.27 | 5 | 78 |
7 | 13 | 50.56 | 20 | 14.91 | 530 | 158 | 5.01 / 599.43 | 5 | 75 |
8 | 8 | -0.16 | 214 | 14.85 | 429 | 1363 | 6.37 / 600.79 | 5 | 131 |
Average= | 7.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.16 | 34 | 14.86 | 567 | 286 | 0.29 / 588.34 | 5 | 16 |
2 | 7 | 2014.20 | 40 | 14.37 | 3563 | 2048 | 2.33 / 590.39 | 16 | 59 |
3 | 13 | 1915.44 | 20 | 14.37 | 3420 | 983 | 3.32 / 591.37 | 5 | 63 |
4 | 13 | 1456.32 | 20 | 14.42 | 2714 | 783 | 4.10 / 592.15 | 5 | 71 |
5 | 13 | 779.40 | 20 | 14.61 | 1681 | 491 | 4.59 / 592.64 | 5 | 82 |
6 | 13 | 204.04 | 20 | 14.84 | 798 | 237 | 4.83 / 592.88 | 5 | 82 |
7 | 13 | 39.08 | 20 | 14.90 | 515 | 153 | 4.98 / 593.03 | 5 | 78 |
8 | 8 | -0.40 | 212 | 14.84 | 440 | 1384 | 6.37 / 594.42 | 5 | 133 |
Average= | 7.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.44 | 34 | 14.88 | 558 | 282 | 0.28 / 582.11 | 5 | 15 |
2 | 7 | 2005.32 | 40 | 14.37 | 3544 | 2037 | 2.32 / 584.15 | 15 | 57 |
3 | 13 | 1915.92 | 20 | 14.36 | 3421 | 983 | 3.30 / 585.13 | 5 | 63 |
4 | 13 | 1387.12 | 20 | 14.43 | 2624 | 757 | 4.06 / 585.89 | 5 | 72 |
5 | 13 | 735.24 | 20 | 14.63 | 1611 | 471 | 4.53 / 586.36 | 5 | 82 |
6 | 13 | 88.84 | 20 | 14.89 | 606 | 180 | 4.71 / 586.54 | 5 | 78 |
7 | 13 | 24.88 | 20 | 14.92 | 482 | 144 | 4.85 / 586.68 | 5 | 73 |
8 | 8 | -0.12 | 214 | 14.85 | 431 | 1370 | 6.22 / 588.05 | 5 | 141 |
Average= | 7.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.68 | 34 | 14.86 | 574 | 290 | 0.29 / 576.15 | 5 | 15 |
2 | 7 | 2006.64 | 40 | 14.38 | 3548 | 2041 | 2.33 / 578.19 | 15 | 58 |
3 | 13 | 1690.96 | 20 | 14.42 | 3091 | 891 | 3.22 / 579.08 | 5 | 67 |
4 | 13 | 1283.80 | 20 | 14.47 | 2460 | 712 | 3.93 / 579.79 | 5 | 73 |
5 | 13 | 570.96 | 20 | 14.71 | 1345 | 396 | 4.33 / 580.19 | 5 | 82 |
6 | 13 | 69.96 | 20 | 14.91 | 560 | 167 | 4.50 / 580.35 | 5 | 75 |
7 | 13 | 21.48 | 20 | 14.93 | 476 | 142 | 4.64 / 580.49 | 5 | 70 |
8 | 8 | -0.08 | 212 | 14.86 | 423 | 1333 | 5.97 / 581.83 | 5 | 129 |
Average= | 7.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.16 | 34 | 14.88 | 554 | 280 | 0.28 / 569.78 | 5 | 14 |
2 | 7 | 2006.88 | 40 | 14.37 | 3543 | 2037 | 2.32 / 571.82 | 14 | 57 |
3 | 13 | 1918.88 | 20 | 14.37 | 3426 | 985 | 3.30 / 572.80 | 5 | 62 |
4 | 13 | 1488.84 | 20 | 14.41 | 2759 | 795 | 4.10 / 573.60 | 5 | 71 |
5 | 13 | 820.64 | 20 | 14.60 | 1747 | 510 | 4.61 / 574.11 | 5 | 81 |
6 | 13 | 168.00 | 20 | 14.86 | 730 | 217 | 4.82 / 574.32 | 5 | 80 |
7 | 13 | 33.28 | 20 | 14.91 | 504 | 150 | 4.97 / 574.47 | 5 | 76 |
8 | 8 | -0.20 | 214 | 14.85 | 435 | 1382 | 6.36 / 575.86 | 5 | 137 |
Average= | 7.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.04 | 34 | 14.87 | 561 | 284 | 0.28 / 563.50 | 5 | 17 |
2 | 7 | 2016.08 | 40 | 14.37 | 3567 | 2050 | 2.33 / 565.55 | 17 | 59 |
3 | 13 | 1920.76 | 20 | 14.37 | 3433 | 987 | 3.32 / 566.54 | 5 | 63 |
4 | 13 | 1469.96 | 20 | 14.42 | 2749 | 793 | 4.11 / 567.33 | 5 | 71 |
5 | 13 | 686.84 | 20 | 14.66 | 1528 | 448 | 4.56 / 567.78 | 5 | 84 |
6 | 13 | 133.36 | 20 | 14.88 | 677 | 201 | 4.76 / 567.98 | 5 | 79 |
7 | 13 | 36.60 | 20 | 14.92 | 508 | 152 | 4.91 / 568.13 | 5 | 72 |
8 | 8 | -0.20 | 214 | 14.86 | 429 | 1364 | 6.28 / 569.50 | 5 | 135 |
Average= | 7.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.80 | 34 | 14.87 | 558 | 282 | 0.28 / 557.28 | 5 | 15 |
2 | 7 | 2013.08 | 40 | 14.37 | 3566 | 2050 | 2.33 / 559.33 | 15 | 58 |
3 | 13 | 1916.16 | 20 | 14.37 | 3419 | 983 | 3.31 / 560.31 | 5 | 63 |
4 | 13 | 1269.36 | 20 | 14.49 | 2429 | 704 | 4.02 / 561.01 | 5 | 72 |
5 | 13 | 840.56 | 20 | 14.59 | 1765 | 515 | 4.53 / 561.53 | 5 | 79 |
6 | 13 | 81.08 | 20 | 14.90 | 584 | 174 | 4.71 / 561.70 | 5 | 76 |
7 | 13 | 43.40 | 20 | 14.91 | 525 | 157 | 4.86 / 561.86 | 5 | 73 |
8 | 8 | -0.12 | 214 | 14.86 | 428 | 1361 | 6.23 / 563.22 | 5 | 131 |
Average= | 7.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.84 | 34 | 14.89 | 547 | 277 | 0.28 / 551.26 | 5 | 14 |
2 | 7 | 2004.56 | 40 | 14.38 | 3544 | 2039 | 2.32 / 553.30 | 14 | 57 |
3 | 13 | 1926.16 | 20 | 14.37 | 3436 | 988 | 3.30 / 554.29 | 5 | 61 |
4 | 13 | 1170.92 | 20 | 14.51 | 2291 | 665 | 3.97 / 554.95 | 5 | 76 |
5 | 13 | 655.00 | 20 | 14.66 | 1486 | 436 | 4.40 / 555.39 | 5 | 81 |
6 | 13 | 66.08 | 20 | 14.92 | 549 | 164 | 4.57 / 555.55 | 5 | 73 |
7 | 13 | 21.88 | 20 | 14.93 | 467 | 139 | 4.71 / 555.69 | 5 | 67 |
8 | 8 | 0.00 | 212 | 14.87 | 414 | 1305 | 6.01 / 557.00 | 5 | 131 |
Average= | 7.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.68 | 34 | 14.88 | 579 | 293 | 0.29 / 545.05 | 5 | 15 |
2 | 7 | 2005.44 | 40 | 14.39 | 3538 | 2036 | 2.33 / 547.08 | 15 | 58 |
3 | 13 | 1907.40 | 20 | 14.38 | 3408 | 980 | 3.31 / 548.06 | 5 | 62 |
4 | 13 | 1446.96 | 20 | 14.43 | 2711 | 782 | 4.09 / 548.85 | 5 | 72 |
5 | 13 | 763.28 | 20 | 14.63 | 1666 | 487 | 4.58 / 549.33 | 5 | 83 |
6 | 13 | 70.16 | 20 | 14.92 | 557 | 166 | 4.75 / 549.50 | 5 | 74 |
7 | 13 | 18.88 | 20 | 14.94 | 462 | 138 | 4.88 / 549.64 | 5 | 68 |
8 | 8 | 0.00 | 216 | 14.87 | 419 | 1346 | 6.23 / 550.98 | 5 | 147 |
Average= | 7.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.72 | 34 | 14.88 | 559 | 283 | 0.28 / 538.34 | 5 | 16 |
2 | 7 | 2008.48 | 40 | 14.39 | 3543 | 2039 | 2.32 / 540.38 | 16 | 59 |
3 | 13 | 1930.88 | 20 | 14.38 | 3431 | 987 | 3.31 / 541.37 | 5 | 63 |
4 | 13 | 1842.68 | 20 | 14.32 | 3299 | 945 | 4.25 / 542.31 | 5 | 65 |
5 | 13 | 767.92 | 20 | 14.64 | 1661 | 486 | 4.74 / 542.80 | 5 | 82 |
6 | 13 | 680.40 | 20 | 14.64 | 1513 | 443 | 5.18 / 543.24 | 5 | 83 |
7 | 13 | 66.36 | 20 | 14.90 | 552 | 164 | 5.35 / 543.41 | 5 | 78 |
8 | 8 | -0.12 | 216 | 14.86 | 420 | 1348 | 6.70 / 544.75 | 5 | 135 |
Average= | 7.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.96 | 34 | 14.89 | 562 | 285 | 0.28 / 532.14 | 5 | 14 |
2 | 7 | 2009.12 | 40 | 14.38 | 3543 | 2038 | 2.32 / 534.18 | 14 | 59 |
3 | 13 | 1929.36 | 20 | 14.36 | 3433 | 986 | 3.31 / 535.17 | 5 | 63 |
4 | 13 | 1292.16 | 20 | 14.48 | 2474 | 716 | 4.02 / 535.88 | 5 | 75 |
5 | 13 | 842.08 | 20 | 14.59 | 1779 | 519 | 4.54 / 536.40 | 5 | 81 |
6 | 13 | 134.12 | 20 | 14.88 | 673 | 200 | 4.74 / 536.60 | 5 | 81 |
7 | 8 | -0.04 | 233 | 14.86 | 420 | 1454 | 6.20 / 538.06 | 5 | 137 |
Average= | 7.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.92 | 34 | 14.89 | 567 | 287 | 0.29 / 525.96 | 5 | 15 |
2 | 3 | 1025.64 | 1 | 15.00 | 2071 | 31 | 0.32 / 525.99 | 5 | 59 |
3 | 7 | 2008.68 | 40 | 14.38 | 3534 | 2033 | 2.35 / 528.02 | 59 | 59 |
4 | 13 | 1921.76 | 20 | 14.37 | 3421 | 983 | 3.33 / 529.00 | 5 | 63 |
5 | 13 | 1291.92 | 20 | 14.47 | 2463 | 713 | 4.05 / 529.72 | 5 | 75 |
6 | 13 | 846.92 | 20 | 14.59 | 1771 | 517 | 4.56 / 530.23 | 5 | 82 |
7 | 13 | 97.12 | 20 | 14.90 | 608 | 181 | 4.74 / 530.41 | 5 | 78 |
8 | 8 | -0.04 | 235 | 14.87 | 414 | 1447 | 6.19 / 531.86 | 5 | 145 |
Average= | 7.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.76 | 34 | 14.87 | 565 | 286 | 0.29 / 519.79 | 5 | 16 |
2 | 7 | 2006.88 | 40 | 14.39 | 3537 | 2036 | 2.32 / 521.83 | 16 | 58 |
3 | 13 | 1920.12 | 20 | 14.38 | 3414 | 982 | 3.30 / 522.81 | 5 | 63 |
4 | 13 | 1340.16 | 20 | 14.47 | 2535 | 734 | 4.04 / 523.54 | 5 | 73 |
5 | 13 | 786.68 | 20 | 14.62 | 1683 | 492 | 4.53 / 524.04 | 5 | 82 |
6 | 13 | 107.36 | 20 | 14.90 | 619 | 184 | 4.71 / 524.22 | 5 | 79 |
7 | 8 | 0.00 | 235 | 14.88 | 414 | 1448 | 6.16 / 525.67 | 5 | 141 |
Average= | 7.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.76 | 34 | 14.89 | 553 | 280 | 0.28 / 513.42 | 5 | 14 |
2 | 7 | 2006.88 | 40 | 14.39 | 3535 | 2035 | 2.31 / 515.45 | 14 | 58 |
3 | 13 | 1814.40 | 20 | 14.40 | 3267 | 941 | 3.26 / 516.39 | 5 | 65 |
4 | 13 | 1380.92 | 20 | 14.45 | 2599 | 751 | 4.01 / 517.14 | 5 | 73 |
5 | 13 | 1056.44 | 20 | 14.51 | 2099 | 609 | 4.62 / 517.75 | 5 | 79 |
6 | 13 | 233.92 | 20 | 14.83 | 829 | 246 | 4.86 / 518.00 | 5 | 83 |
7 | 13 | 55.80 | 20 | 14.91 | 533 | 159 | 5.02 / 518.16 | 5 | 76 |
8 | 8 | -0.20 | 216 | 14.86 | 420 | 1348 | 6.37 / 519.51 | 5 | 136 |
Average= | 7.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.72 | 34 | 14.89 | 556 | 281 | 0.28 / 507.38 | 5 | 16 |
2 | 7 | 2005.36 | 40 | 14.39 | 3540 | 2038 | 2.32 / 509.42 | 16 | 58 |
3 | 13 | 1712.76 | 20 | 14.42 | 3101 | 894 | 3.21 / 510.31 | 5 | 66 |
4 | 13 | 1214.84 | 20 | 14.50 | 2341 | 679 | 3.89 / 510.99 | 5 | 73 |
5 | 13 | 795.36 | 20 | 14.62 | 1700 | 497 | 4.39 / 511.49 | 5 | 82 |
6 | 13 | 127.52 | 20 | 14.89 | 653 | 194 | 4.58 / 511.68 | 5 | 79 |
7 | 13 | 29.96 | 20 | 14.93 | 470 | 140 | 4.72 / 511.82 | 5 | 67 |
8 | 8 | 0.00 | 217 | 14.87 | 407 | 1313 | 6.04 / 513.14 | 5 | 151 |
Average= | 8.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.28 | 34 | 14.88 | 568 | 287 | 0.29 / 501.23 | 5 | 15 |
2 | 7 | 2013.28 | 40 | 14.40 | 3541 | 2040 | 2.33 / 503.27 | 15 | 57 |
3 | 13 | 1919.52 | 20 | 14.39 | 3399 | 978 | 3.31 / 504.25 | 5 | 62 |
4 | 13 | 1378.64 | 20 | 14.47 | 2596 | 751 | 4.06 / 505.00 | 5 | 72 |
5 | 13 | 740.96 | 20 | 14.65 | 1617 | 474 | 4.53 / 505.47 | 5 | 82 |
6 | 13 | 97.40 | 20 | 14.91 | 599 | 179 | 4.71 / 505.65 | 5 | 76 |
7 | 13 | 26.20 | 20 | 14.94 | 470 | 140 | 4.85 / 505.79 | 5 | 67 |
8 | 8 | -0.12 | 216 | 14.88 | 408 | 1311 | 6.16 / 507.10 | 5 | 152 |
Average= | 8.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.48 | 34 | 14.90 | 554 | 281 | 0.28 / 494.97 | 5 | 15 |
2 | 7 | 2013.12 | 40 | 14.39 | 3538 | 2036 | 2.32 / 497.01 | 15 | 58 |
3 | 13 | 1925.40 | 20 | 14.39 | 3410 | 981 | 3.30 / 497.99 | 5 | 61 |
4 | 13 | 1406.60 | 20 | 14.45 | 2631 | 760 | 4.06 / 498.75 | 5 | 72 |
5 | 13 | 848.32 | 20 | 14.60 | 1777 | 519 | 4.58 / 499.27 | 5 | 81 |
6 | 13 | 100.20 | 20 | 14.91 | 607 | 181 | 4.76 / 499.45 | 5 | 76 |
7 | 13 | 55.76 | 20 | 14.92 | 531 | 158 | 4.92 / 499.61 | 5 | 71 |
8 | 8 | -0.08 | 214 | 14.87 | 419 | 1333 | 6.25 / 500.94 | 5 | 132 |
Average= | 8.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.36 | 34 | 14.90 | 566 | 287 | 0.29 / 488.82 | 5 | 15 |
2 | 7 | 2004.48 | 40 | 14.39 | 3530 | 2032 | 2.32 / 490.85 | 15 | 58 |
3 | 13 | 1911.60 | 20 | 14.39 | 3401 | 979 | 3.30 / 491.83 | 5 | 61 |
4 | 13 | 1286.84 | 20 | 14.49 | 2456 | 712 | 4.01 / 492.54 | 5 | 74 |
5 | 13 | 847.12 | 20 | 14.60 | 1781 | 520 | 4.53 / 493.06 | 5 | 80 |
6 | 13 | 109.56 | 20 | 14.91 | 621 | 185 | 4.71 / 493.24 | 5 | 75 |
7 | 13 | 38.32 | 20 | 14.94 | 486 | 145 | 4.86 / 493.39 | 5 | 64 |
8 | 8 | 0.08 | 216 | 14.89 | 404 | 1299 | 6.16 / 494.69 | 5 | 139 |
Average= | 8.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.88 | 34 | 14.89 | 561 | 284 | 0.28 / 482.68 | 5 | 16 |
2 | 7 | 2003.40 | 40 | 14.41 | 3523 | 2031 | 2.31 / 484.71 | 16 | 57 |
3 | 13 | 1812.40 | 20 | 14.42 | 3246 | 936 | 3.25 / 485.65 | 5 | 64 |
4 | 13 | 1403.80 | 20 | 14.46 | 2618 | 757 | 4.01 / 486.40 | 5 | 72 |
5 | 13 | 739.88 | 20 | 14.66 | 1614 | 473 | 4.48 / 486.88 | 5 | 80 |
6 | 13 | 161.68 | 20 | 14.88 | 722 | 215 | 4.70 / 487.09 | 5 | 81 |
7 | 8 | 0.00 | 238 | 14.89 | 406 | 1439 | 6.13 / 488.53 | 5 | 154 |
Average= | 8.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.96 | 34 | 14.89 | 550 | 278 | 0.28 / 476.51 | 5 | 16 |
2 | 7 | 2011.44 | 40 | 14.41 | 3533 | 2036 | 2.31 / 478.55 | 44 | 57 |
3 | 13 | 1816.72 | 20 | 14.42 | 3257 | 939 | 3.25 / 479.49 | 5 | 65 |
4 | 13 | 1503.60 | 20 | 14.43 | 2794 | 806 | 4.06 / 480.30 | 5 | 71 |
5 | 13 | 646.00 | 20 | 14.70 | 1460 | 429 | 4.49 / 480.72 | 5 | 81 |
6 | 13 | 99.40 | 20 | 14.93 | 597 | 178 | 4.67 / 480.90 | 5 | 77 |
7 | 13 | 55.92 | 20 | 14.94 | 520 | 155 | 4.82 / 481.06 | 5 | 72 |
8 | 8 | -0.04 | 216 | 14.88 | 416 | 1337 | 6.16 / 482.40 | 5 | 144 |
Average= | 8.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.64 | 34 | 14.89 | 565 | 286 | 0.29 / 470.22 | 5 | 17 |
2 | 7 | 2013.72 | 40 | 14.41 | 3533 | 2036 | 2.32 / 472.26 | 17 | 57 |
3 | 13 | 1931.08 | 20 | 14.39 | 3413 | 982 | 3.30 / 473.24 | 5 | 62 |
4 | 13 | 1389.32 | 20 | 14.48 | 2594 | 751 | 4.06 / 473.99 | 5 | 71 |
5 | 13 | 645.76 | 20 | 14.71 | 1450 | 427 | 4.48 / 474.42 | 5 | 81 |
6 | 13 | 438.08 | 20 | 14.77 | 1128 | 333 | 4.82 / 474.75 | 5 | 83 |
7 | 13 | 37.48 | 20 | 14.94 | 491 | 147 | 4.96 / 474.90 | 5 | 74 |
8 | 8 | -0.08 | 216 | 14.88 | 415 | 1334 | 6.30 / 476.24 | 5 | 135 |
Average= | 8.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.84 | 34 | 14.87 | 574 | 290 | 0.29 / 463.98 | 5 | 18 |
2 | 10 | 1019.48 | 3 | 14.86 | 2035 | 91 | 0.38 / 464.07 | 5 | 60 |
3 | 3 | 943.84 | -1 | 15.35 | 0 | 0 | 0.09 / 464.07 | 5 | 60 |
4 | 7 | 2005.64 | 40 | 14.41 | 3509 | 2023 | 2.40 / 466.09 | 60 | 59 |
5 | 13 | 1809.52 | 20 | 14.43 | 3231 | 932 | 3.34 / 467.02 | 5 | 64 |
6 | 13 | 1387.80 | 20 | 14.48 | 2593 | 751 | 4.09 / 467.77 | 5 | 71 |
7 | 13 | 837.72 | 20 | 14.62 | 1755 | 513 | 4.60 / 468.29 | 5 | 81 |
8 | 13 | 66.36 | 20 | 14.94 | 549 | 164 | 4.76 / 468.45 | 5 | 78 |
9 | 13 | 36.36 | 20 | 14.94 | 500 | 149 | 4.91 / 468.60 | 5 | 77 |
10 | 8 | -0.20 | 214 | 14.88 | 420 | 1337 | 6.25 / 469.94 | 5 | 145 |
Average= | 8.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.68 | 34 | 14.90 | 568 | 288 | 0.29 / 457.76 | 5 | 17 |
2 | 7 | 2006.40 | 40 | 14.41 | 3527 | 2033 | 2.32 / 459.79 | 17 | 57 |
3 | 13 | 1919.28 | 20 | 14.41 | 3399 | 980 | 3.30 / 460.77 | 5 | 62 |
4 | 13 | 1019.92 | 20 | 14.60 | 2032 | 593 | 3.89 / 461.37 | 5 | 76 |
5 | 13 | 935.76 | 20 | 14.58 | 1908 | 556 | 4.45 / 461.92 | 5 | 79 |
6 | 13 | 351.72 | 20 | 14.80 | 1012 | 300 | 4.75 / 462.22 | 5 | 84 |
7 | 8 | 0.12 | 232 | 14.87 | 425 | 1466 | 6.22 / 463.69 | 5 | 132 |
Average= | 8.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.16 | 34 | 14.89 | 549 | 278 | 0.28 / 451.68 | 5 | 17 |
2 | 7 | 2009.00 | 40 | 14.41 | 3534 | 2037 | 2.31 / 453.71 | 17 | 57 |
3 | 13 | 1911.80 | 20 | 14.41 | 3382 | 975 | 3.29 / 454.69 | 5 | 62 |
4 | 13 | 1194.08 | 20 | 14.54 | 2314 | 673 | 3.96 / 455.36 | 5 | 74 |
5 | 13 | 854.72 | 20 | 14.62 | 1780 | 520 | 4.48 / 455.88 | 5 | 81 |
6 | 13 | 44.80 | 20 | 14.95 | 509 | 152 | 4.64 / 456.03 | 5 | 77 |
7 | 8 | -0.20 | 233 | 14.89 | 415 | 1440 | 6.07 / 457.47 | 5 | 137 |
Average= | 8.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.80 | 34 | 14.89 | 550 | 278 | 0.28 / 445.21 | 5 | 18 |
2 | 7 | 2010.12 | 40 | 14.41 | 3539 | 2040 | 2.32 / 447.25 | 18 | 58 |
3 | 13 | 1914.72 | 20 | 14.41 | 3404 | 981 | 3.30 / 448.23 | 5 | 63 |
4 | 13 | 1481.40 | 20 | 14.45 | 2748 | 794 | 4.09 / 449.03 | 5 | 72 |
5 | 13 | 1030.44 | 20 | 14.56 | 2056 | 599 | 4.69 / 449.63 | 5 | 78 |
6 | 13 | 325.20 | 20 | 14.82 | 976 | 289 | 4.98 / 449.92 | 5 | 83 |
7 | 13 | 34.36 | 20 | 14.94 | 488 | 146 | 5.13 / 450.06 | 5 | 79 |
8 | 8 | -0.36 | 214 | 14.88 | 419 | 1334 | 6.46 / 451.40 | 5 | 134 |
Average= | 8.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.84 | 34 | 14.91 | 541 | 274 | 0.27 / 438.83 | 5 | 17 |
2 | 7 | 2010.48 | 40 | 14.41 | 3537 | 2039 | 2.31 / 440.87 | 17 | 57 |
3 | 13 | 1931.60 | 20 | 14.41 | 3428 | 988 | 3.30 / 441.86 | 5 | 62 |
4 | 13 | 1484.64 | 20 | 14.45 | 2748 | 794 | 4.10 / 442.65 | 5 | 72 |
5 | 13 | 808.92 | 20 | 14.65 | 1716 | 503 | 4.60 / 443.16 | 5 | 82 |
6 | 13 | 336.88 | 20 | 14.82 | 985 | 292 | 4.89 / 443.45 | 5 | 85 |
7 | 13 | 15.56 | 20 | 14.95 | 460 | 138 | 5.03 / 443.59 | 5 | 77 |
8 | 8 | 0.56 | 214 | 14.87 | 424 | 1349 | 6.38 / 444.94 | 5 | 140 |
Average= | 8.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.00 | 34 | 14.91 | 538 | 273 | 0.27 / 432.74 | 5 | 16 |
2 | 7 | 2004.32 | 40 | 14.42 | 3521 | 2031 | 2.30 / 434.77 | 16 | 58 |
3 | 13 | 1909.52 | 20 | 14.42 | 3371 | 972 | 3.28 / 435.74 | 5 | 61 |
4 | 13 | 1379.96 | 20 | 14.49 | 2578 | 747 | 4.02 / 436.49 | 5 | 72 |
5 | 13 | 726.60 | 20 | 14.68 | 1582 | 464 | 4.49 / 436.95 | 5 | 82 |
6 | 13 | 49.48 | 20 | 14.96 | 510 | 153 | 4.64 / 437.10 | 5 | 77 |
7 | 13 | 30.12 | 20 | 14.96 | 478 | 143 | 4.78 / 437.25 | 5 | 77 |
8 | 8 | -0.20 | 214 | 14.89 | 412 | 1313 | 6.10 / 438.56 | 5 | 135 |
Average= | 8.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.88 | 34 | 14.91 | 552 | 280 | 0.28 / 426.52 | 5 | 15 |
2 | 10 | 1000.88 | 3 | 14.88 | 2005 | 90 | 0.37 / 426.61 | 5 | 61 |
3 | 3 | 926.60 | -1 | 15.37 | 0 | 0 | 0.09 / 426.61 | 5 | 61 |
4 | 7 | 2011.84 | 40 | 14.42 | 3530 | 2036 | 2.41 / 428.65 | 61 | 58 |
5 | 13 | 1928.28 | 20 | 14.42 | 3401 | 981 | 3.39 / 429.63 | 5 | 62 |
6 | 13 | 1396.52 | 20 | 14.48 | 2607 | 755 | 4.14 / 430.38 | 5 | 72 |
7 | 13 | 715.24 | 20 | 14.68 | 1568 | 460 | 4.60 / 430.84 | 5 | 81 |
8 | 13 | 82.12 | 20 | 14.94 | 571 | 171 | 4.77 / 431.01 | 5 | 80 |
9 | 13 | 22.60 | 20 | 14.96 | 470 | 141 | 4.91 / 431.15 | 5 | 75 |
10 | 8 | -0.12 | 212 | 14.89 | 415 | 1310 | 6.22 / 432.46 | 5 | 133 |
Average= | 8.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.72 | 34 | 14.91 | 534 | 271 | 0.27 / 420.54 | 5 | 14 |
2 | 7 | 2014.24 | 40 | 14.42 | 3529 | 2036 | 2.31 / 422.58 | 14 | 58 |
3 | 13 | 1612.60 | 20 | 14.48 | 2931 | 849 | 3.16 / 423.42 | 5 | 66 |
4 | 13 | 1415.80 | 20 | 14.48 | 2609 | 756 | 3.91 / 424.18 | 5 | 71 |
5 | 13 | 663.24 | 20 | 14.70 | 1476 | 434 | 4.34 / 424.61 | 5 | 79 |
6 | 13 | 56.64 | 20 | 14.95 | 529 | 158 | 4.50 / 424.77 | 5 | 78 |
7 | 13 | 31.28 | 20 | 14.95 | 487 | 146 | 4.65 / 424.92 | 5 | 77 |
8 | 8 | -0.24 | 212 | 14.89 | 419 | 1323 | 5.97 / 426.24 | 5 | 132 |
Average= | 8.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.64 | 34 | 14.92 | 528 | 268 | 0.27 / 414.48 | 5 | 14 |
2 | 7 | 2011.60 | 40 | 14.42 | 3511 | 2025 | 2.29 / 416.50 | 14 | 58 |
3 | 13 | 1915.24 | 20 | 14.42 | 3384 | 976 | 3.27 / 417.48 | 5 | 63 |
4 | 13 | 1287.96 | 20 | 14.52 | 2433 | 707 | 3.98 / 418.18 | 5 | 73 |
5 | 13 | 738.32 | 20 | 14.68 | 1593 | 468 | 4.44 / 418.65 | 5 | 82 |
6 | 13 | 84.48 | 20 | 14.94 | 572 | 171 | 4.61 / 418.82 | 5 | 80 |
7 | 13 | 23.72 | 20 | 14.96 | 468 | 140 | 4.75 / 418.96 | 5 | 75 |
8 | 8 | -0.20 | 214 | 14.90 | 410 | 1307 | 6.06 / 420.27 | 5 | 138 |
Average= | 8.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.80 | 34 | 14.92 | 526 | 267 | 0.27 / 408.29 | 5 | 14 |
2 | 7 | 2005.96 | 40 | 14.43 | 3523 | 2033 | 2.30 / 410.32 | 14 | 59 |
3 | 13 | 1915.00 | 20 | 14.42 | 3393 | 979 | 3.28 / 411.30 | 5 | 62 |
4 | 13 | 1376.40 | 20 | 14.49 | 2589 | 750 | 4.03 / 412.05 | 5 | 72 |
5 | 13 | 936.52 | 20 | 14.59 | 1919 | 560 | 4.59 / 412.61 | 5 | 80 |
6 | 13 | 82.80 | 20 | 14.95 | 570 | 170 | 4.76 / 412.78 | 5 | 79 |
7 | 13 | 24.32 | 20 | 14.96 | 462 | 138 | 4.90 / 412.92 | 5 | 72 |
8 | 8 | -0.16 | 216 | 14.90 | 401 | 1291 | 6.19 / 414.21 | 5 | 148 |
Average= | 8.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.08 | 34 | 14.92 | 542 | 275 | 0.27 / 402.16 | 5 | 13 |
2 | 7 | 2008.60 | 41 | 14.41 | 3530 | 2086 | 2.36 / 404.25 | 13 | 58 |
3 | 13 | 1913.16 | 20 | 14.41 | 3391 | 977 | 3.34 / 405.22 | 5 | 62 |
4 | 13 | 1367.32 | 20 | 14.49 | 2571 | 745 | 4.08 / 405.97 | 5 | 73 |
5 | 13 | 703.04 | 20 | 14.69 | 1554 | 457 | 4.54 / 406.43 | 5 | 85 |
6 | 13 | 76.44 | 20 | 14.95 | 559 | 167 | 4.71 / 406.59 | 5 | 76 |
7 | 13 | 25.48 | 20 | 14.97 | 460 | 138 | 4.84 / 406.73 | 5 | 69 |
8 | 8 | -0.08 | 216 | 14.91 | 400 | 1288 | 6.13 / 408.02 | 5 | 146 |
Average= | 8.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.64 | 34 | 14.93 | 534 | 271 | 0.27 / 396.00 | 5 | 14 |
2 | 7 | 2004.76 | 41 | 14.42 | 3512 | 2076 | 2.35 / 398.07 | 14 | 57 |
3 | 13 | 1910.40 | 20 | 14.42 | 3378 | 974 | 3.32 / 399.05 | 5 | 63 |
4 | 13 | 1253.32 | 20 | 14.53 | 2399 | 697 | 4.02 / 399.74 | 5 | 74 |
5 | 13 | 816.24 | 20 | 14.64 | 1726 | 505 | 4.52 / 400.25 | 5 | 82 |
6 | 13 | 114.92 | 20 | 14.93 | 621 | 185 | 4.71 / 400.43 | 5 | 78 |
7 | 13 | 61.68 | 20 | 14.95 | 532 | 159 | 4.87 / 400.59 | 5 | 75 |
8 | 8 | -0.04 | 216 | 14.90 | 402 | 1294 | 6.16 / 401.89 | 5 | 139 |
Average= | 8.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.44 | 34 | 14.93 | 528 | 268 | 0.27 / 389.85 | 5 | 14 |
2 | 7 | 2005.12 | 40 | 14.44 | 3523 | 2035 | 2.30 / 391.89 | 14 | 58 |
3 | 13 | 1913.88 | 20 | 14.43 | 3382 | 976 | 3.28 / 392.86 | 5 | 62 |
4 | 13 | 1451.88 | 20 | 14.48 | 2682 | 777 | 4.06 / 393.64 | 5 | 70 |
5 | 13 | 766.36 | 20 | 14.68 | 1636 | 480 | 4.54 / 394.12 | 5 | 81 |
6 | 13 | 107.40 | 20 | 14.95 | 609 | 182 | 4.72 / 394.30 | 5 | 78 |
7 | 13 | 31.00 | 20 | 14.97 | 472 | 141 | 4.86 / 394.44 | 5 | 68 |
8 | 8 | -0.04 | 216 | 14.92 | 397 | 1279 | 6.14 / 395.72 | 5 | 132 |
Average= | 8.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.52 | 34 | 14.93 | 542 | 275 | 0.28 / 383.81 | 5 | 14 |
2 | 7 | 2008.36 | 40 | 14.43 | 3521 | 2032 | 2.31 / 385.85 | 14 | 58 |
3 | 13 | 1807.64 | 20 | 14.45 | 3226 | 932 | 3.24 / 386.78 | 5 | 63 |
4 | 13 | 1274.36 | 20 | 14.53 | 2411 | 701 | 3.94 / 387.48 | 5 | 74 |
5 | 13 | 840.04 | 20 | 14.64 | 1751 | 513 | 4.45 / 387.99 | 5 | 80 |
6 | 13 | 86.44 | 20 | 14.95 | 567 | 170 | 4.62 / 388.16 | 5 | 78 |
7 | 13 | 46.44 | 20 | 14.96 | 501 | 150 | 4.77 / 388.31 | 5 | 75 |
8 | 8 | -0.12 | 214 | 14.92 | 399 | 1274 | 6.05 / 389.59 | 5 | 134 |
Average= | 8.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.56 | 34 | 14.93 | 548 | 278 | 0.28 / 377.78 | 5 | 15 |
2 | 7 | 2006.68 | 40 | 14.44 | 3514 | 2030 | 2.31 / 379.81 | 15 | 58 |
3 | 13 | 1914.48 | 20 | 14.43 | 3373 | 973 | 3.28 / 380.78 | 5 | 62 |
4 | 13 | 1173.08 | 20 | 14.57 | 2265 | 660 | 3.94 / 381.44 | 5 | 76 |
5 | 13 | 742.40 | 20 | 14.69 | 1603 | 471 | 4.41 / 381.91 | 5 | 82 |
6 | 13 | 87.56 | 20 | 14.95 | 574 | 172 | 4.58 / 382.08 | 5 | 80 |
7 | 13 | 26.08 | 20 | 14.97 | 470 | 141 | 4.72 / 382.22 | 5 | 73 |
8 | 8 | -0.08 | 216 | 14.92 | 408 | 1315 | 6.04 / 383.54 | 5 | 144 |
Average= | 8.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.36 | 34 | 14.93 | 548 | 278 | 0.28 / 371.58 | 5 | 14 |
2 | 7 | 2005.04 | 41 | 14.44 | 3508 | 2077 | 2.36 / 373.66 | 14 | 57 |
3 | 13 | 1909.80 | 20 | 14.44 | 3362 | 971 | 3.33 / 374.63 | 5 | 62 |
4 | 13 | 1467.60 | 20 | 14.48 | 2714 | 786 | 4.11 / 375.41 | 5 | 71 |
5 | 13 | 784.36 | 20 | 14.68 | 1660 | 487 | 4.60 / 375.90 | 5 | 82 |
6 | 13 | 73.12 | 20 | 14.97 | 544 | 163 | 4.76 / 376.06 | 5 | 76 |
7 | 13 | 39.48 | 20 | 14.98 | 488 | 146 | 4.91 / 376.21 | 5 | 73 |
8 | 8 | -0.16 | 214 | 14.93 | 404 | 1291 | 6.20 / 377.50 | 5 | 129 |
Average= | 8.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.88 | 34 | 14.95 | 531 | 270 | 0.27 / 365.50 | 5 | 14 |
2 | 7 | 2007.04 | 41 | 14.44 | 3504 | 2075 | 2.34 / 367.58 | 14 | 58 |
3 | 13 | 1922.96 | 20 | 14.44 | 3373 | 974 | 3.32 / 368.55 | 5 | 61 |
4 | 13 | 1269.56 | 20 | 14.55 | 2402 | 699 | 4.02 / 369.25 | 5 | 74 |
5 | 13 | 725.12 | 20 | 14.70 | 1568 | 461 | 4.48 / 369.71 | 5 | 82 |
6 | 13 | 84.72 | 20 | 14.97 | 557 | 167 | 4.65 / 369.88 | 5 | 77 |
7 | 13 | 46.20 | 20 | 14.97 | 494 | 148 | 4.79 / 370.03 | 5 | 75 |
8 | 8 | -0.04 | 214 | 14.93 | 399 | 1275 | 6.07 / 371.30 | 5 | 133 |
Average= | 9.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.24 | 34 | 14.94 | 542 | 275 | 0.28 / 359.41 | 5 | 14 |
2 | 7 | 2012.44 | 40 | 14.45 | 3510 | 2029 | 2.30 / 361.44 | 14 | 57 |
3 | 13 | 1915.56 | 20 | 14.45 | 3386 | 979 | 3.28 / 362.42 | 5 | 62 |
4 | 13 | 1374.56 | 20 | 14.52 | 2553 | 741 | 4.02 / 363.16 | 5 | 72 |
5 | 13 | 727.44 | 20 | 14.71 | 1571 | 462 | 4.49 / 363.62 | 5 | 83 |
6 | 13 | 91.64 | 20 | 14.97 | 570 | 171 | 4.66 / 363.79 | 5 | 80 |
7 | 13 | 50.64 | 20 | 14.97 | 502 | 150 | 4.81 / 363.94 | 5 | 76 |
8 | 8 | -0.12 | 216 | 14.93 | 400 | 1290 | 6.10 / 365.23 | 5 | 142 |
Average= | 9.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.04 | 34 | 14.96 | 533 | 271 | 0.27 / 353.37 | 5 | 14 |
2 | 7 | 2009.28 | 40 | 14.45 | 3503 | 2025 | 2.30 / 355.40 | 14 | 57 |
3 | 13 | 1916.36 | 20 | 14.45 | 3388 | 979 | 3.27 / 356.38 | 5 | 62 |
4 | 13 | 1276.24 | 20 | 14.55 | 2420 | 704 | 3.98 / 357.08 | 5 | 73 |
5 | 13 | 647.52 | 20 | 14.74 | 1453 | 428 | 4.41 / 357.51 | 5 | 81 |
6 | 13 | 109.56 | 20 | 14.96 | 603 | 180 | 4.59 / 357.69 | 5 | 78 |
7 | 13 | 59.20 | 20 | 14.98 | 514 | 154 | 4.74 / 357.84 | 5 | 73 |
8 | 8 | -0.12 | 218 | 14.94 | 397 | 1293 | 6.03 / 359.14 | 5 | 145 |
Average= | 9.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.88 | 34 | 14.95 | 537 | 273 | 0.27 / 347.22 | 5 | 16 |
2 | 7 | 2015.40 | 40 | 14.45 | 3523 | 2036 | 2.31 / 349.26 | 16 | 58 |
3 | 13 | 1927.36 | 20 | 14.44 | 3401 | 982 | 3.29 / 350.24 | 5 | 61 |
4 | 13 | 1284.92 | 20 | 14.55 | 2433 | 708 | 4.00 / 350.95 | 5 | 73 |
5 | 13 | 875.24 | 20 | 14.66 | 1803 | 529 | 4.53 / 351.48 | 5 | 80 |
6 | 13 | 104.72 | 20 | 14.98 | 599 | 179 | 4.71 / 351.66 | 5 | 78 |
7 | 13 | 59.04 | 20 | 14.99 | 515 | 154 | 4.86 / 351.81 | 5 | 74 |
8 | 8 | -0.12 | 218 | 14.95 | 395 | 1287 | 6.15 / 353.10 | 5 | 144 |
Average= | 9.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.64 | 33 | 14.95 | 550 | 271 | 0.27 / 341.03 | 5 | 16 |
2 | 3 | 1036.12 | 1 | 14.99 | 2071 | 31 | 0.30 / 341.06 | 5 | 68 |
3 | 7 | 2011.44 | 40 | 14.46 | 3509 | 2030 | 2.33 / 343.09 | 68 | 57 |
4 | 13 | 1914.96 | 20 | 14.45 | 3377 | 976 | 3.31 / 344.07 | 5 | 62 |
5 | 13 | 1492.36 | 20 | 14.50 | 2743 | 795 | 4.10 / 344.86 | 5 | 70 |
6 | 13 | 799.52 | 20 | 14.70 | 1685 | 495 | 4.60 / 345.36 | 5 | 80 |
7 | 13 | 75.00 | 20 | 14.99 | 542 | 162 | 4.76 / 345.52 | 5 | 79 |
8 | 13 | 41.36 | 20 | 15.00 | 490 | 147 | 4.91 / 345.67 | 5 | 78 |
9 | 8 | -0.16 | 216 | 14.95 | 397 | 1282 | 6.19 / 346.95 | 5 | 136 |
Average= | 9.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.52 | 34 | 14.96 | 529 | 269 | 0.27 / 335.05 | 5 | 16 |
2 | 3 | 966.20 | -1 | 15.40 | 0 | 0 | 0.00 / 335.05 | 5 | 16 |
3 | 7 | 2008.80 | 41 | 14.46 | 3506 | 2079 | 2.35 / 337.13 | 16 | 57 |
4 | 13 | 1922.12 | 20 | 14.45 | 3381 | 977 | 3.32 / 338.11 | 5 | 61 |
5 | 13 | 1272.08 | 20 | 14.57 | 2392 | 697 | 4.02 / 338.81 | 5 | 72 |
6 | 13 | 536.24 | 20 | 14.82 | 1266 | 375 | 4.40 / 339.18 | 5 | 83 |
7 | 13 | 65.76 | 20 | 15.00 | 534 | 160 | 4.56 / 339.34 | 5 | 80 |
8 | 13 | 19.84 | 20 | 15.01 | 451 | 135 | 4.69 / 339.48 | 5 | 76 |
9 | 8 | -0.16 | 214 | 14.95 | 401 | 1283 | 5.98 / 340.76 | 5 | 133 |
Average= | 9.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.04 | 34 | 14.96 | 539 | 274 | 0.27 / 328.99 | 5 | 15 |
2 | 7 | 2018.04 | 40 | 14.45 | 3525 | 2037 | 2.31 / 331.02 | 15 | 57 |
3 | 13 | 1934.80 | 20 | 14.45 | 3410 | 985 | 3.30 / 332.01 | 5 | 62 |
4 | 13 | 1221.24 | 20 | 14.59 | 2328 | 679 | 3.98 / 332.69 | 5 | 74 |
5 | 13 | 897.00 | 20 | 14.67 | 1821 | 534 | 4.51 / 333.22 | 5 | 79 |
6 | 13 | 60.28 | 20 | 15.01 | 519 | 156 | 4.67 / 333.38 | 5 | 79 |
7 | 13 | 16.88 | 20 | 15.02 | 448 | 135 | 4.80 / 333.51 | 5 | 76 |
8 | 8 | -0.20 | 214 | 14.96 | 397 | 1271 | 6.07 / 334.79 | 5 | 131 |
Average= | 9.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.68 | 34 | 14.97 | 538 | 274 | 0.27 / 322.94 | 5 | 16 |
2 | 7 | 2010.44 | 40 | 14.47 | 3508 | 2030 | 2.30 / 324.97 | 16 | 57 |
3 | 13 | 1810.48 | 20 | 14.49 | 3214 | 931 | 3.24 / 325.90 | 5 | 64 |
4 | 13 | 1378.12 | 20 | 14.54 | 2562 | 745 | 3.98 / 326.65 | 5 | 72 |
5 | 13 | 712.28 | 20 | 14.75 | 1542 | 455 | 4.44 / 327.10 | 5 | 83 |
6 | 13 | 146.72 | 20 | 14.97 | 670 | 201 | 4.64 / 327.30 | 5 | 82 |
7 | 13 | 32.64 | 20 | 15.01 | 472 | 142 | 4.78 / 327.44 | 5 | 79 |
8 | 8 | -0.04 | 212 | 14.95 | 401 | 1271 | 6.05 / 328.71 | 5 | 129 |
Average= | 9.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.08 | 34 | 14.98 | 549 | 280 | 0.28 / 316.93 | 5 | 16 |
2 | 7 | 2008.84 | 40 | 14.46 | 3506 | 2028 | 2.31 / 318.95 | 16 | 57 |
3 | 13 | 1911.92 | 20 | 14.46 | 3380 | 977 | 3.28 / 319.93 | 5 | 63 |
4 | 13 | 1189.32 | 20 | 14.61 | 2281 | 667 | 3.95 / 320.60 | 5 | 75 |
5 | 13 | 771.52 | 20 | 14.73 | 1637 | 482 | 4.43 / 321.08 | 5 | 82 |
6 | 13 | 59.24 | 20 | 15.02 | 519 | 156 | 4.59 / 321.24 | 5 | 78 |
7 | 13 | 36.12 | 20 | 15.02 | 480 | 144 | 4.73 / 321.38 | 5 | 77 |
8 | 8 | -0.16 | 212 | 14.96 | 405 | 1284 | 6.02 / 322.66 | 5 | 129 |
Average= | 9.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.56 | 34 | 14.99 | 555 | 283 | 0.28 / 310.82 | 5 | 16 |
2 | 7 | 2006.80 | 41 | 14.46 | 3514 | 2083 | 2.37 / 312.91 | 52 | 57 |
3 | 13 | 1813.56 | 20 | 14.48 | 3212 | 930 | 3.30 / 313.84 | 5 | 64 |
4 | 13 | 1392.12 | 20 | 14.54 | 2591 | 753 | 4.05 / 314.59 | 5 | 73 |
5 | 13 | 623.08 | 20 | 14.79 | 1407 | 416 | 4.47 / 315.01 | 5 | 83 |
6 | 13 | 90.80 | 20 | 15.01 | 582 | 175 | 4.64 / 315.18 | 5 | 81 |
7 | 13 | 48.16 | 20 | 15.02 | 510 | 153 | 4.79 / 315.34 | 5 | 78 |
8 | 8 | -0.24 | 214 | 14.97 | 409 | 1310 | 6.10 / 316.65 | 5 | 136 |
Average= | 9.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.72 | 33 | 14.99 | 534 | 264 | 0.26 / 304.37 | 5 | 16 |
2 | 3 | 1021.76 | 1 | 15.08 | 2013 | 30 | 0.29 / 304.40 | 5 | 44 |
3 | 7 | 2006.92 | 41 | 14.47 | 3494 | 2073 | 2.37 / 306.47 | 44 | 58 |
4 | 13 | 1923.44 | 20 | 14.46 | 3369 | 974 | 3.34 / 307.44 | 5 | 62 |
5 | 13 | 1829.28 | 20 | 14.42 | 3244 | 936 | 4.28 / 308.38 | 5 | 65 |
6 | 13 | 883.08 | 20 | 14.70 | 1810 | 532 | 4.81 / 308.91 | 5 | 80 |
7 | 13 | 100.48 | 20 | 15.01 | 592 | 178 | 4.99 / 309.09 | 5 | 79 |
8 | 13 | 27.80 | 20 | 15.04 | 468 | 141 | 5.13 / 309.23 | 5 | 72 |
9 | 8 | -0.08 | 218 | 14.98 | 402 | 1313 | 6.44 / 310.54 | 5 | 150 |
Average= | 10.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.72 | 34 | 15.00 | 531 | 271 | 0.27 / 298.38 | 5 | 16 |
2 | 3 | 967.84 | -1 | 15.41 | 0 | 0 | 0.00 / 298.38 | 5 | 16 |
3 | 7 | 2004.48 | 40 | 14.47 | 3487 | 2018 | 2.29 / 300.40 | 16 | 59 |
4 | 13 | 1920.60 | 20 | 14.48 | 3355 | 972 | 3.26 / 301.37 | 5 | 62 |
5 | 13 | 1096.44 | 20 | 14.66 | 2124 | 623 | 3.88 / 302.00 | 5 | 76 |
6 | 13 | 782.80 | 20 | 14.74 | 1656 | 488 | 4.37 / 302.48 | 5 | 80 |
7 | 13 | 207.88 | 20 | 14.96 | 762 | 228 | 4.60 / 302.71 | 5 | 84 |
8 | 13 | 23.36 | 20 | 15.04 | 442 | 133 | 4.73 / 302.84 | 5 | 71 |
9 | 8 | -0.04 | 216 | 14.99 | 388 | 1256 | 5.99 / 304.10 | 5 | 144 |
Average= | 10.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.64 | 34 | 15.01 | 539 | 275 | 0.28 / 292.28 | 5 | 15 |
2 | 7 | 2006.00 | 40 | 14.48 | 3492 | 2023 | 2.30 / 294.30 | 15 | 59 |
3 | 13 | 1922.52 | 20 | 14.47 | 3379 | 978 | 3.28 / 295.28 | 5 | 62 |
4 | 13 | 1523.56 | 20 | 14.51 | 2781 | 807 | 4.08 / 296.09 | 5 | 70 |
5 | 13 | 596.60 | 20 | 14.82 | 1361 | 403 | 4.49 / 296.49 | 5 | 82 |
6 | 13 | 158.24 | 20 | 14.99 | 687 | 206 | 4.69 / 296.70 | 5 | 84 |
7 | 13 | 35.08 | 20 | 15.04 | 475 | 143 | 4.83 / 296.84 | 5 | 77 |
8 | 8 | -0.16 | 214 | 14.99 | 396 | 1270 | 6.11 / 298.11 | 5 | 132 |
Average= | 10.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.96 | 34 | 15.02 | 527 | 269 | 0.27 / 286.22 | 5 | 16 |
2 | 7 | 2004.80 | 40 | 14.48 | 3496 | 2025 | 2.29 / 288.25 | 16 | 58 |
3 | 13 | 1808.04 | 20 | 14.50 | 3204 | 929 | 3.22 / 289.18 | 5 | 64 |
4 | 13 | 1387.84 | 20 | 14.56 | 2563 | 746 | 3.97 / 289.92 | 5 | 72 |
5 | 13 | 826.24 | 20 | 14.73 | 1713 | 505 | 4.47 / 290.43 | 5 | 80 |
6 | 13 | 75.68 | 20 | 15.04 | 535 | 161 | 4.64 / 290.59 | 5 | 75 |
7 | 13 | 51.44 | 20 | 15.04 | 494 | 149 | 4.78 / 290.74 | 5 | 72 |
8 | 8 | -0.16 | 214 | 15.00 | 396 | 1271 | 6.05 / 292.01 | 5 | 132 |
Average= | 10.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.56 | 34 | 15.01 | 526 | 268 | 0.27 / 280.30 | 5 | 16 |
2 | 7 | 2003.52 | 41 | 14.47 | 3490 | 2071 | 2.34 / 282.37 | 16 | 59 |
3 | 13 | 1805.84 | 20 | 14.51 | 3203 | 930 | 3.27 / 283.30 | 5 | 65 |
4 | 13 | 1180.64 | 20 | 14.64 | 2268 | 664 | 3.93 / 283.96 | 5 | 76 |
5 | 13 | 674.68 | 20 | 14.80 | 1488 | 440 | 4.37 / 284.40 | 5 | 82 |
6 | 13 | 90.72 | 20 | 15.05 | 553 | 166 | 4.54 / 284.57 | 5 | 72 |
7 | 13 | 23.36 | 20 | 15.07 | 438 | 132 | 4.67 / 284.70 | 5 | 65 |
8 | 8 | -0.04 | 216 | 15.02 | 385 | 1249 | 5.92 / 285.95 | 5 | 151 |
Average= | 10.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.92 | 34 | 15.03 | 531 | 271 | 0.27 / 273.75 | 5 | 16 |
2 | 7 | 2014.28 | 40 | 14.47 | 3515 | 2034 | 2.31 / 275.78 | 16 | 58 |
3 | 13 | 1942.32 | 20 | 14.47 | 3412 | 987 | 3.29 / 276.77 | 5 | 61 |
4 | 13 | 1852.40 | 20 | 14.43 | 3272 | 944 | 4.24 / 277.71 | 5 | 64 |
5 | 13 | 973.44 | 20 | 14.69 | 1948 | 572 | 4.81 / 278.29 | 5 | 80 |
6 | 13 | 356.64 | 20 | 14.91 | 1017 | 303 | 5.11 / 278.59 | 5 | 86 |
7 | 13 | 28.52 | 20 | 15.07 | 450 | 136 | 5.25 / 278.72 | 5 | 71 |
8 | 8 | -0.24 | 220 | 15.00 | 396 | 1307 | 6.56 / 280.03 | 5 | 141 |
Average= | 10.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.64 | 34 | 15.04 | 534 | 273 | 0.27 / 267.70 | 5 | 16 |
2 | 7 | 2004.80 | 40 | 14.49 | 3480 | 2017 | 2.29 / 269.72 | 16 | 58 |
3 | 13 | 1919.28 | 20 | 14.49 | 3347 | 970 | 3.26 / 270.69 | 5 | 62 |
4 | 13 | 1274.24 | 20 | 14.62 | 2389 | 699 | 3.96 / 271.39 | 5 | 73 |
5 | 13 | 830.80 | 20 | 14.75 | 1712 | 505 | 4.46 / 271.89 | 5 | 81 |
6 | 13 | 145.48 | 20 | 15.02 | 655 | 197 | 4.66 / 272.09 | 5 | 82 |
7 | 13 | 45.04 | 20 | 15.07 | 470 | 142 | 4.80 / 272.23 | 5 | 72 |
8 | 8 | -0.12 | 218 | 15.02 | 380 | 1244 | 6.05 / 273.48 | 5 | 143 |
Average= | 10.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.40 | 34 | 15.03 | 532 | 272 | 0.27 / 261.63 | 5 | 16 |
2 | 7 | 2007.60 | 40 | 14.48 | 3486 | 2019 | 2.29 / 263.65 | 16 | 58 |
3 | 13 | 1917.20 | 20 | 14.49 | 3357 | 973 | 3.26 / 264.62 | 5 | 63 |
4 | 13 | 1479.32 | 20 | 14.55 | 2706 | 787 | 4.05 / 265.41 | 5 | 71 |
5 | 13 | 801.36 | 20 | 14.77 | 1668 | 493 | 4.54 / 265.90 | 5 | 81 |
6 | 13 | 129.80 | 20 | 15.04 | 622 | 187 | 4.73 / 266.09 | 5 | 79 |
7 | 8 | 0.08 | 238 | 15.04 | 375 | 1342 | 6.07 / 267.43 | 5 | 146 |
Average= | 11.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.64 | 34 | 15.04 | 535 | 274 | 0.27 / 255.63 | 5 | 17 |
2 | 7 | 2008.48 | 40 | 14.49 | 3498 | 2027 | 2.30 / 257.66 | 17 | 59 |
3 | 13 | 1808.84 | 20 | 14.52 | 3204 | 930 | 3.23 / 258.59 | 5 | 65 |
4 | 13 | 1382.04 | 20 | 14.59 | 2553 | 745 | 3.98 / 259.33 | 5 | 72 |
5 | 13 | 705.64 | 20 | 14.81 | 1528 | 453 | 4.43 / 259.78 | 5 | 84 |
6 | 13 | 88.68 | 20 | 15.07 | 550 | 166 | 4.59 / 259.95 | 5 | 75 |
7 | 13 | 47.84 | 20 | 15.07 | 479 | 144 | 4.74 / 260.09 | 5 | 70 |
8 | 8 | 0.04 | 216 | 15.03 | 389 | 1263 | 6.00 / 261.36 | 5 | 149 |
Average= | 11.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.12 | 34 | 15.04 | 532 | 272 | 0.27 / 249.31 | 5 | 19 |
2 | 7 | 2013.92 | 40 | 14.50 | 3505 | 2033 | 2.30 / 251.34 | 19 | 58 |
3 | 13 | 1929.80 | 20 | 14.49 | 3396 | 984 | 3.29 / 252.32 | 5 | 61 |
4 | 13 | 1487.96 | 20 | 14.57 | 2708 | 789 | 4.08 / 253.11 | 5 | 70 |
5 | 13 | 1034.80 | 20 | 14.69 | 2037 | 598 | 4.68 / 253.71 | 5 | 79 |
6 | 13 | 206.56 | 20 | 15.01 | 760 | 228 | 4.90 / 253.94 | 5 | 84 |
7 | 13 | 46.28 | 20 | 15.07 | 488 | 147 | 5.05 / 254.09 | 5 | 75 |
8 | 8 | -0.12 | 214 | 15.03 | 394 | 1267 | 6.32 / 255.35 | 5 | 132 |
Average= | 11.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.00 | 34 | 15.03 | 542 | 277 | 0.28 / 243.29 | 5 | 17 |
2 | 7 | 2011.64 | 40 | 14.50 | 3499 | 2029 | 2.31 / 245.32 | 17 | 58 |
3 | 13 | 1918.16 | 20 | 14.50 | 3386 | 982 | 3.29 / 246.30 | 5 | 62 |
4 | 13 | 1283.16 | 20 | 14.64 | 2414 | 707 | 4.00 / 247.01 | 5 | 73 |
5 | 13 | 736.32 | 20 | 14.81 | 1577 | 467 | 4.46 / 247.48 | 5 | 82 |
6 | 13 | 82.16 | 20 | 15.07 | 552 | 166 | 4.63 / 247.64 | 5 | 82 |
7 | 13 | 26.32 | 20 | 15.09 | 449 | 136 | 4.76 / 247.78 | 5 | 78 |
8 | 8 | -0.28 | 212 | 15.03 | 394 | 1255 | 6.02 / 249.04 | 5 | 136 |
Average= | 11.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.44 | 34 | 15.05 | 519 | 266 | 0.27 / 237.07 | 5 | 16 |
2 | 7 | 2013.60 | 40 | 14.49 | 3511 | 2035 | 2.30 / 239.10 | 16 | 57 |
3 | 13 | 1916.44 | 20 | 14.50 | 3367 | 976 | 3.28 / 240.08 | 5 | 62 |
4 | 13 | 1500.32 | 20 | 14.56 | 2751 | 801 | 4.08 / 240.88 | 5 | 70 |
5 | 13 | 676.12 | 20 | 14.84 | 1490 | 442 | 4.52 / 241.32 | 5 | 82 |
6 | 13 | 330.00 | 20 | 14.96 | 953 | 285 | 4.81 / 241.61 | 5 | 87 |
7 | 13 | 37.08 | 20 | 15.08 | 468 | 141 | 4.95 / 241.75 | 5 | 78 |
8 | 8 | -0.16 | 216 | 15.03 | 390 | 1266 | 6.21 / 243.02 | 5 | 140 |
Average= | 12.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.56 | 33 | 15.06 | 506 | 251 | 0.25 / 231.10 | 5 | 17 |
2 | 7 | 2002.56 | 40 | 14.51 | 3476 | 2017 | 2.27 / 233.12 | 27 | 58 |
3 | 13 | 1802.44 | 20 | 14.54 | 3194 | 929 | 3.20 / 234.05 | 5 | 64 |
4 | 13 | 1394.56 | 20 | 14.60 | 2591 | 757 | 3.95 / 234.80 | 5 | 72 |
5 | 13 | 742.92 | 20 | 14.81 | 1590 | 471 | 4.43 / 235.27 | 5 | 82 |
6 | 13 | 83.20 | 20 | 15.08 | 545 | 164 | 4.59 / 235.44 | 5 | 80 |
7 | 13 | 22.08 | 20 | 15.10 | 431 | 130 | 4.72 / 235.57 | 5 | 73 |
8 | 8 | -0.16 | 214 | 15.05 | 383 | 1234 | 5.95 / 236.80 | 5 | 131 |
Average= | 12.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.76 | 33 | 15.05 | 511 | 254 | 0.25 / 225.05 | 5 | 21 |
2 | 10 | 1007.32 | 3 | 14.95 | 2000 | 90 | 0.34 / 225.14 | 5 | 64 |
3 | 3 | 937.32 | -1 | 15.44 | 0 | 0 | 0.09 / 225.14 | 5 | 64 |
4 | 7 | 2004.92 | 41 | 14.51 | 3480 | 2070 | 2.41 / 227.21 | 64 | 58 |
5 | 13 | 1803.36 | 20 | 14.54 | 3184 | 926 | 3.34 / 228.14 | 5 | 64 |
6 | 13 | 1267.52 | 20 | 14.66 | 2385 | 699 | 4.04 / 228.84 | 5 | 74 |
7 | 13 | 934.80 | 20 | 14.74 | 1877 | 553 | 4.59 / 229.39 | 5 | 81 |
8 | 13 | 57.28 | 20 | 15.09 | 501 | 151 | 4.74 / 229.54 | 5 | 82 |
9 | 8 | -0.08 | 231 | 15.06 | 376 | 1308 | 6.05 / 230.85 | 5 | 139 |
Average= | 12.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.04 | 33 | 15.07 | 537 | 267 | 0.27 / 218.96 | 5 | 18 |
2 | 7 | 2006.12 | 40 | 14.51 | 3478 | 2019 | 2.29 / 220.98 | 18 | 58 |
3 | 13 | 1909.28 | 20 | 14.52 | 3351 | 973 | 3.26 / 221.95 | 5 | 62 |
4 | 13 | 1467.36 | 20 | 14.60 | 2675 | 781 | 4.04 / 222.73 | 5 | 71 |
5 | 13 | 833.36 | 20 | 14.79 | 1715 | 507 | 4.55 / 223.24 | 5 | 82 |
6 | 13 | 124.84 | 20 | 15.07 | 613 | 185 | 4.73 / 223.43 | 5 | 85 |
7 | 13 | 26.56 | 20 | 15.10 | 444 | 134 | 4.87 / 223.56 | 5 | 83 |
8 | 8 | -0.32 | 212 | 15.05 | 388 | 1238 | 6.10 / 224.80 | 5 | 143 |
Average= | 13.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.24 | 33 | 15.08 | 517 | 257 | 0.26 / 213.01 | 5 | 17 |
2 | 7 | 2005.00 | 40 | 14.51 | 3475 | 2017 | 2.27 / 215.03 | 17 | 58 |
3 | 13 | 1909.40 | 20 | 14.51 | 3345 | 971 | 3.24 / 216.00 | 5 | 63 |
4 | 13 | 1043.00 | 20 | 14.75 | 2053 | 606 | 3.85 / 216.60 | 5 | 77 |
5 | 13 | 957.20 | 20 | 14.74 | 1916 | 565 | 4.42 / 217.17 | 5 | 80 |
6 | 13 | 69.52 | 20 | 15.10 | 524 | 158 | 4.57 / 217.33 | 5 | 81 |
7 | 13 | 15.52 | 20 | 15.11 | 430 | 130 | 4.70 / 217.46 | 5 | 78 |
8 | 8 | -0.24 | 210 | 15.05 | 392 | 1239 | 5.94 / 218.69 | 5 | 133 |
Average= | 13.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.80 | 33 | 15.08 | 514 | 256 | 0.26 / 206.97 | 5 | 15 |
2 | 7 | 2004.12 | 40 | 14.51 | 3488 | 2024 | 2.28 / 208.99 | 15 | 58 |
3 | 13 | 1911.76 | 20 | 14.52 | 3339 | 970 | 3.25 / 209.96 | 5 | 62 |
4 | 13 | 1469.96 | 20 | 14.60 | 2668 | 779 | 4.03 / 210.74 | 5 | 71 |
5 | 13 | 781.00 | 20 | 14.82 | 1635 | 485 | 4.51 / 211.23 | 5 | 82 |
6 | 13 | 64.40 | 20 | 15.11 | 510 | 154 | 4.67 / 211.38 | 5 | 79 |
7 | 13 | 18.88 | 20 | 15.12 | 435 | 132 | 4.80 / 211.51 | 5 | 75 |
8 | 8 | -0.24 | 214 | 15.07 | 384 | 1238 | 6.04 / 212.75 | 5 | 138 |
Average= | 14.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.44 | 33 | 15.09 | 513 | 255 | 0.26 / 201.10 | 5 | 14 |
2 | 7 | 2010.16 | 41 | 14.50 | 3475 | 2066 | 2.32 / 203.16 | 14 | 58 |
3 | 13 | 1714.16 | 20 | 14.57 | 3051 | 889 | 3.21 / 204.05 | 5 | 67 |
4 | 13 | 1309.12 | 20 | 14.65 | 2453 | 719 | 3.93 / 204.77 | 5 | 75 |
5 | 13 | 665.28 | 20 | 14.86 | 1467 | 436 | 4.37 / 205.21 | 5 | 84 |
6 | 13 | 99.92 | 20 | 15.09 | 569 | 172 | 4.54 / 205.38 | 5 | 80 |
7 | 13 | 56.88 | 20 | 15.11 | 490 | 148 | 4.68 / 205.53 | 5 | 75 |
8 | 8 | -0.04 | 214 | 15.07 | 368 | 1187 | 5.87 / 206.71 | 5 | 149 |
Average= | 14.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.00 | 33 | 15.10 | 511 | 255 | 0.25 / 195.08 | 5 | 13 |
2 | 7 | 2005.52 | 40 | 14.51 | 3481 | 2020 | 2.28 / 197.10 | 13 | 58 |
3 | 13 | 1922.60 | 20 | 14.52 | 3348 | 972 | 3.25 / 198.07 | 5 | 62 |
4 | 13 | 1391.12 | 20 | 14.63 | 2566 | 751 | 4.00 / 198.82 | 5 | 73 |
5 | 13 | 825.88 | 20 | 14.81 | 1696 | 502 | 4.50 / 199.32 | 5 | 81 |
6 | 13 | 149.24 | 20 | 15.08 | 641 | 193 | 4.69 / 199.51 | 5 | 79 |
7 | 13 | 42.32 | 20 | 15.13 | 444 | 134 | 4.83 / 199.65 | 5 | 66 |
8 | 8 | 0.08 | 218 | 15.08 | 363 | 1193 | 6.02 / 200.84 | 5 | 146 |
Average= | 15.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.36 | 33 | 15.09 | 522 | 260 | 0.26 / 189.25 | 5 | 14 |
2 | 7 | 2010.08 | 40 | 14.51 | 3489 | 2025 | 2.28 / 191.27 | 21 | 58 |
3 | 13 | 1912.20 | 20 | 14.52 | 3332 | 968 | 3.25 / 192.24 | 5 | 62 |
4 | 13 | 1188.16 | 20 | 14.70 | 2279 | 670 | 3.92 / 192.91 | 5 | 75 |
5 | 13 | 645.68 | 20 | 14.88 | 1433 | 426 | 4.35 / 193.34 | 5 | 82 |
6 | 13 | 112.56 | 20 | 15.11 | 582 | 176 | 4.52 / 193.51 | 5 | 75 |
7 | 13 | 34.84 | 20 | 15.14 | 440 | 133 | 4.66 / 193.64 | 5 | 64 |
8 | 8 | 0.04 | 216 | 15.09 | 361 | 1177 | 5.83 / 194.82 | 5 | 133 |
Average= | 16.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.32 | 33 | 15.10 | 519 | 259 | 0.26 / 183.32 | 5 | 14 |
2 | 7 | 2016.20 | 40 | 14.51 | 3494 | 2028 | 2.29 / 185.34 | 14 | 58 |
3 | 13 | 1925.12 | 20 | 14.52 | 3358 | 975 | 3.26 / 186.32 | 5 | 62 |
4 | 13 | 1291.20 | 20 | 14.67 | 2411 | 707 | 3.97 / 187.03 | 5 | 75 |
5 | 13 | 732.52 | 20 | 14.85 | 1563 | 464 | 4.43 / 187.49 | 5 | 82 |
6 | 13 | 92.48 | 20 | 15.12 | 552 | 167 | 4.60 / 187.66 | 5 | 75 |
7 | 13 | 25.96 | 20 | 15.14 | 426 | 129 | 4.73 / 187.79 | 5 | 68 |
8 | 8 | -0.04 | 216 | 15.09 | 368 | 1199 | 5.93 / 188.99 | 5 | 143 |
Average= | 17.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.48 | 33 | 15.11 | 516 | 257 | 0.26 / 177.27 | 5 | 14 |
2 | 7 | 2014.00 | 40 | 14.52 | 3484 | 2024 | 2.28 / 179.29 | 14 | 59 |
3 | 13 | 1919.52 | 20 | 14.53 | 3347 | 973 | 3.25 / 180.27 | 5 | 62 |
4 | 13 | 1594.20 | 20 | 14.57 | 2865 | 835 | 4.09 / 181.10 | 5 | 70 |
5 | 13 | 582.80 | 20 | 14.93 | 1317 | 393 | 4.48 / 181.49 | 5 | 83 |
6 | 13 | 167.24 | 20 | 15.08 | 673 | 203 | 4.68 / 181.70 | 5 | 82 |
7 | 13 | 91.64 | 20 | 15.12 | 537 | 162 | 4.85 / 181.86 | 5 | 74 |
8 | 8 | -0.12 | 218 | 15.09 | 364 | 1197 | 6.04 / 183.06 | 5 | 145 |
Average= | 18.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.32 | 33 | 15.11 | 523 | 261 | 0.26 / 171.26 | 5 | 14 |
2 | 7 | 2006.56 | 40 | 14.52 | 3476 | 2019 | 2.28 / 173.28 | 14 | 58 |
3 | 13 | 1914.92 | 20 | 14.53 | 3352 | 974 | 3.25 / 174.25 | 5 | 62 |
4 | 13 | 1496.80 | 20 | 14.61 | 2721 | 795 | 4.05 / 175.05 | 5 | 72 |
5 | 13 | 686.16 | 20 | 14.88 | 1493 | 444 | 4.49 / 175.49 | 5 | 83 |
6 | 13 | 161.36 | 20 | 15.10 | 657 | 198 | 4.69 / 175.69 | 5 | 78 |
7 | 13 | 40.44 | 20 | 15.15 | 438 | 133 | 4.82 / 175.82 | 5 | 62 |
8 | 8 | 0.00 | 218 | 15.10 | 362 | 1192 | 6.02 / 177.01 | 5 | 159 |
Average= | 19.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.32 | 33 | 15.11 | 515 | 257 | 0.26 / 165.18 | 5 | 15 |
2 | 7 | 2013.08 | 41 | 14.52 | 3486 | 2075 | 2.33 / 167.26 | 15 | 57 |
3 | 13 | 1924.64 | 20 | 14.53 | 3369 | 979 | 3.31 / 168.24 | 5 | 62 |
4 | 13 | 1486.56 | 20 | 14.61 | 2709 | 792 | 4.10 / 169.03 | 5 | 72 |
5 | 13 | 619.48 | 20 | 14.92 | 1386 | 414 | 4.52 / 169.44 | 5 | 84 |
6 | 13 | 161.28 | 20 | 15.09 | 668 | 202 | 4.72 / 169.64 | 5 | 81 |
7 | 13 | 41.96 | 20 | 15.15 | 454 | 138 | 4.86 / 169.78 | 5 | 66 |
8 | 8 | 0.00 | 216 | 15.10 | 373 | 1217 | 6.07 / 171.00 | 5 | 133 |
Average= | 21.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.96 | 33 | 15.11 | 518 | 258 | 0.26 / 159.24 | 5 | 15 |
2 | 7 | 2010.08 | 40 | 14.53 | 3474 | 2019 | 2.28 / 161.26 | 15 | 57 |
3 | 13 | 1914.16 | 20 | 14.55 | 3353 | 976 | 3.25 / 162.24 | 5 | 62 |
4 | 13 | 1261.00 | 20 | 14.70 | 2376 | 699 | 3.95 / 162.94 | 5 | 74 |
5 | 13 | 734.52 | 20 | 14.87 | 1556 | 463 | 4.41 / 163.40 | 5 | 81 |
6 | 13 | 150.24 | 20 | 15.10 | 650 | 196 | 4.61 / 163.59 | 5 | 80 |
7 | 8 | 0.16 | 238 | 15.11 | 370 | 1331 | 5.94 / 164.93 | 5 | 144 |
Average= | 23.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.68 | 33 | 15.12 | 511 | 255 | 0.25 / 153.39 | 5 | 14 |
2 | 7 | 2009.64 | 40 | 14.53 | 3483 | 2024 | 2.28 / 155.41 | 20 | 59 |
3 | 13 | 1920.76 | 20 | 14.54 | 3346 | 973 | 3.25 / 156.39 | 5 | 62 |
4 | 13 | 1258.96 | 20 | 14.71 | 2361 | 695 | 3.95 / 157.08 | 5 | 74 |
5 | 13 | 633.20 | 20 | 14.92 | 1407 | 420 | 4.37 / 157.50 | 5 | 83 |
6 | 13 | 115.20 | 20 | 15.13 | 575 | 174 | 4.54 / 157.67 | 5 | 74 |
7 | 13 | 15.72 | 20 | 15.17 | 400 | 121 | 4.66 / 157.80 | 5 | 62 |
8 | 8 | -0.04 | 216 | 15.11 | 364 | 1188 | 5.85 / 158.98 | 5 | 145 |
Average= | 26.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.96 | 33 | 15.12 | 506 | 252 | 0.25 / 147.33 | 5 | 16 |
2 | 7 | 2013.84 | 40 | 14.54 | 3493 | 2032 | 2.28 / 149.36 | 16 | 57 |
3 | 13 | 1924.16 | 20 | 14.55 | 3361 | 978 | 3.26 / 150.34 | 5 | 62 |
4 | 13 | 1483.32 | 20 | 14.63 | 2702 | 791 | 4.05 / 151.13 | 5 | 71 |
5 | 13 | 691.68 | 20 | 14.89 | 1494 | 445 | 4.50 / 151.57 | 5 | 83 |
6 | 13 | 143.28 | 20 | 15.11 | 640 | 193 | 4.69 / 151.77 | 5 | 83 |
7 | 13 | 76.00 | 20 | 15.13 | 516 | 156 | 4.85 / 151.92 | 5 | 76 |
8 | 8 | -0.04 | 218 | 15.11 | 368 | 1212 | 6.06 / 153.13 | 5 | 149 |
Average= | 30.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.56 | 33 | 15.12 | 507 | 253 | 0.25 / 141.58 | 5 | 15 |
2 | 7 | 2004.88 | 40 | 14.54 | 3479 | 2023 | 2.28 / 143.60 | 15 | 58 |
3 | 13 | 1706.60 | 20 | 14.61 | 3040 | 888 | 3.16 / 144.49 | 5 | 66 |
4 | 13 | 1177.52 | 20 | 14.74 | 2242 | 661 | 3.83 / 145.15 | 5 | 76 |
5 | 13 | 645.08 | 20 | 14.91 | 1427 | 426 | 4.25 / 145.58 | 5 | 83 |
6 | 13 | 63.68 | 20 | 15.15 | 497 | 151 | 4.40 / 145.73 | 5 | 78 |
7 | 13 | 19.72 | 20 | 15.16 | 429 | 130 | 4.53 / 145.86 | 5 | 72 |
8 | 8 | -0.08 | 212 | 15.11 | 379 | 1214 | 5.75 / 147.07 | 5 | 131 |
Average= | 36.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.08 | 33 | 15.12 | 499 | 249 | 0.25 / 135.70 | 5 | 16 |
2 | 7 | 2007.44 | 40 | 14.54 | 3470 | 2018 | 2.27 / 137.72 | 16 | 57 |
3 | 13 | 1816.80 | 20 | 14.58 | 3199 | 933 | 3.20 / 138.65 | 5 | 65 |
4 | 13 | 1280.04 | 20 | 14.71 | 2398 | 705 | 3.91 / 139.36 | 5 | 74 |
5 | 13 | 728.92 | 20 | 14.88 | 1559 | 464 | 4.37 / 139.82 | 5 | 83 |
6 | 13 | 78.84 | 20 | 15.14 | 533 | 161 | 4.53 / 139.99 | 5 | 80 |
7 | 13 | 25.16 | 20 | 15.16 | 437 | 132 | 4.66 / 140.12 | 5 | 75 |
8 | 8 | -0.12 | 212 | 15.11 | 378 | 1211 | 5.87 / 141.33 | 5 | 130 |
Average= | 47.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.04 | 33 | 15.13 | 511 | 255 | 0.26 / 129.77 | 5 | 18 |
2 | 7 | 2004.32 | 40 | 14.55 | 3485 | 2028 | 2.28 / 131.80 | 18 | 57 |
3 | 13 | 1810.24 | 20 | 14.60 | 3185 | 930 | 3.21 / 132.73 | 5 | 64 |
4 | 13 | 1074.32 | 20 | 14.79 | 2075 | 614 | 3.83 / 133.35 | 5 | 77 |
5 | 13 | 984.60 | 20 | 14.79 | 1945 | 575 | 4.40 / 133.92 | 5 | 79 |
6 | 13 | 148.32 | 20 | 15.12 | 638 | 193 | 4.60 / 134.11 | 5 | 83 |
7 | 13 | 37.88 | 20 | 15.16 | 452 | 137 | 4.73 / 134.25 | 5 | 78 |
8 | 8 | -0.12 | 214 | 15.12 | 372 | 1204 | 5.94 / 135.45 | 5 | 137 |
Average= | 67.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.00 | 33 | 15.13 | 503 | 251 | 0.25 / 123.99 | 5 | 15 |
2 | 7 | 2009.64 | 40 | 14.56 | 3485 | 2030 | 2.28 / 126.01 | 15 | 57 |
3 | 13 | 1911.56 | 20 | 14.57 | 3340 | 973 | 3.25 / 126.99 | 5 | 61 |
4 | 13 | 1115.68 | 20 | 14.79 | 2148 | 635 | 3.89 / 127.62 | 5 | 75 |
5 | 13 | 594.72 | 20 | 14.95 | 1349 | 403 | 4.29 / 128.03 | 5 | 84 |
6 | 13 | 64.28 | 20 | 15.16 | 504 | 153 | 4.45 / 128.18 | 5 | 82 |
7 | 13 | 17.80 | 20 | 15.17 | 424 | 129 | 4.57 / 128.31 | 5 | 78 |
8 | 8 | -0.28 | 210 | 15.12 | 381 | 1210 | 5.78 / 129.52 | 5 | 133 |
Average= | 129.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.24 | 33 | 15.14 | 485 | 242 | 0.24 / 117.87 | 5 | 16 |
2 | 7 | 2008.00 | 40 | 14.56 | 3467 | 2019 | 2.26 / 119.89 | 16 | 58 |
3 | 13 | 1911.72 | 20 | 14.57 | 3334 | 972 | 3.23 / 120.86 | 5 | 63 |
4 | 13 | 1607.08 | 20 | 14.62 | 2880 | 842 | 4.08 / 121.71 | 5 | 69 |
5 | 13 | 656.00 | 20 | 14.93 | 1439 | 430 | 4.50 / 122.14 | 5 | 84 |
6 | 13 | 259.28 | 20 | 15.08 | 817 | 246 | 4.75 / 122.38 | 5 | 85 |
7 | 13 | 23.88 | 20 | 15.18 | 423 | 128 | 4.88 / 122.51 | 5 | 77 |
8 | 8 | -0.12 | 218 | 15.12 | 371 | 1223 | 6.10 / 123.73 | 5 | 144 |
Average= | 5.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.60 | 32 | 15.14 | 502 | 243 | 0.24 / 111.85 | 5 | 17 |
2 | 3 | 1022.52 | 1 | 15.17 | 1994 | 30 | 0.27 / 111.88 | 5 | 14 |
3 | 7 | 2004.12 | 40 | 14.57 | 3453 | 2012 | 2.29 / 113.89 | 14 | 59 |
4 | 13 | 1794.24 | 20 | 14.61 | 3165 | 925 | 3.21 / 114.82 | 5 | 65 |
5 | 13 | 1594.48 | 20 | 14.61 | 2865 | 837 | 4.05 / 115.66 | 5 | 70 |
6 | 13 | 802.44 | 20 | 14.88 | 1658 | 493 | 4.54 / 116.15 | 5 | 82 |
7 | 13 | 80.56 | 20 | 15.17 | 517 | 157 | 4.70 / 116.31 | 5 | 80 |
8 | 13 | 23.16 | 20 | 15.19 | 416 | 126 | 4.82 / 116.43 | 5 | 73 |
9 | 8 | -0.04 | 218 | 15.14 | 363 | 1198 | 6.02 / 117.63 | 5 | 144 |
Average= | 5.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.12 | 33 | 15.15 | 490 | 245 | 0.24 / 105.94 | 5 | 16 |
2 | 7 | 2017.72 | 40 | 14.56 | 3498 | 2037 | 2.28 / 107.98 | 16 | 58 |
3 | 13 | 1932.36 | 20 | 14.57 | 3368 | 981 | 3.26 / 108.96 | 5 | 62 |
4 | 13 | 1210.04 | 20 | 14.76 | 2283 | 674 | 3.94 / 109.64 | 5 | 77 |
5 | 13 | 772.00 | 20 | 14.89 | 1603 | 477 | 4.41 / 110.11 | 5 | 83 |
6 | 13 | 197.92 | 20 | 15.11 | 717 | 217 | 4.63 / 110.33 | 5 | 85 |
7 | 13 | 19.12 | 20 | 15.19 | 405 | 123 | 4.75 / 110.45 | 5 | 76 |
8 | 8 | -0.28 | 216 | 15.14 | 353 | 1154 | 5.91 / 111.61 | 5 | 144 |
Average= | 5.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.04 | 33 | 15.15 | 490 | 245 | 0.24 / 100.11 | 5 | 15 |
2 | 7 | 2004.36 | 40 | 14.57 | 3437 | 2003 | 2.25 / 102.12 | 15 | 57 |
3 | 13 | 1807.36 | 20 | 14.61 | 3164 | 925 | 3.17 / 103.04 | 5 | 65 |
4 | 13 | 1502.08 | 20 | 14.66 | 2695 | 790 | 3.96 / 103.83 | 5 | 71 |
5 | 13 | 688.44 | 20 | 14.93 | 1462 | 437 | 4.40 / 104.27 | 5 | 84 |
6 | 13 | 85.68 | 20 | 15.17 | 511 | 155 | 4.55 / 104.42 | 5 | 78 |
7 | 13 | 20.84 | 20 | 15.20 | 404 | 123 | 4.68 / 104.54 | 5 | 70 |
8 | 8 | -0.12 | 216 | 15.15 | 353 | 1155 | 5.83 / 105.70 | 5 | 133 |
Average= | 5.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.48 | 33 | 15.16 | 486 | 243 | 0.24 / 94.44 | 5 | 17 |
2 | 7 | 2009.04 | 40 | 14.58 | 3445 | 2009 | 2.25 / 96.44 | 17 | 58 |
3 | 13 | 1706.44 | 20 | 14.65 | 3005 | 880 | 3.13 / 97.33 | 5 | 66 |
4 | 13 | 1302.36 | 20 | 14.74 | 2396 | 706 | 3.84 / 98.03 | 5 | 74 |
5 | 13 | 646.08 | 20 | 14.96 | 1389 | 416 | 4.25 / 98.45 | 5 | 85 |
6 | 13 | 102.92 | 20 | 15.17 | 534 | 162 | 4.42 / 98.61 | 5 | 81 |
7 | 8 | -0.04 | 238 | 15.15 | 349 | 1258 | 5.68 / 99.87 | 5 | 130 |
Average= | 5.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.12 | 33 | 15.17 | 477 | 239 | 0.24 / 88.61 | 5 | 16 |
2 | 7 | 2004.72 | 41 | 14.58 | 3429 | 2050 | 2.29 / 90.66 | 16 | 58 |
3 | 13 | 1818.76 | 20 | 14.62 | 3169 | 927 | 3.22 / 91.59 | 5 | 65 |
4 | 13 | 1402.24 | 20 | 14.71 | 2532 | 745 | 3.96 / 92.33 | 5 | 73 |
5 | 13 | 841.04 | 20 | 14.88 | 1686 | 502 | 4.46 / 92.84 | 5 | 82 |
6 | 13 | 75.88 | 20 | 15.19 | 479 | 146 | 4.61 / 92.98 | 5 | 76 |
7 | 13 | 19.72 | 20 | 15.21 | 376 | 114 | 4.72 / 93.10 | 5 | 70 |
8 | 8 | -0.12 | 220 | 15.16 | 329 | 1097 | 5.82 / 94.19 | 5 | 140 |
Average= | 5.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.68 | 33 | 15.17 | 478 | 239 | 0.24 / 82.74 | 5 | 16 |
2 | 7 | 2012.16 | 40 | 14.58 | 3451 | 2013 | 2.25 / 84.75 | 16 | 58 |
3 | 13 | 1914.48 | 20 | 14.60 | 3311 | 967 | 3.22 / 85.72 | 5 | 63 |
4 | 13 | 1366.52 | 20 | 14.73 | 2486 | 732 | 3.95 / 86.45 | 5 | 74 |
5 | 13 | 1012.16 | 20 | 14.82 | 1946 | 577 | 4.53 / 87.03 | 5 | 80 |
6 | 13 | 65.12 | 20 | 15.21 | 447 | 136 | 4.66 / 87.16 | 5 | 72 |
7 | 13 | 45.00 | 20 | 15.21 | 414 | 126 | 4.79 / 87.29 | 5 | 69 |
8 | 8 | -0.12 | 223 | 15.17 | 321 | 1086 | 5.88 / 88.37 | 5 | 152 |
Average= | 5.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.84 | 33 | 15.17 | 482 | 241 | 0.24 / 77.01 | 5 | 15 |
2 | 7 | 2012.60 | 40 | 14.60 | 3423 | 1999 | 2.24 / 79.01 | 15 | 58 |
3 | 13 | 1920.32 | 20 | 14.61 | 3302 | 965 | 3.21 / 79.97 | 5 | 62 |
4 | 13 | 1255.68 | 20 | 14.78 | 2294 | 678 | 3.88 / 80.65 | 5 | 74 |
5 | 13 | 718.80 | 20 | 14.95 | 1430 | 428 | 4.31 / 81.08 | 5 | 73 |
6 | 13 | 89.48 | 20 | 15.20 | 489 | 149 | 4.46 / 81.23 | 5 | 77 |
7 | 13 | 49.88 | 20 | 15.21 | 426 | 130 | 4.59 / 81.36 | 5 | 73 |
8 | 13 | 27.96 | 20 | 15.21 | 391 | 119 | 4.71 / 81.48 | 5 | 71 |
9 | 8 | -0.20 | 208 | 15.17 | 324 | 1022 | 5.73 / 82.50 | 5 | 129 |
Average= | 5.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.80 | 33 | 15.16 | 480 | 240 | 0.24 / 71.32 | 5 | 15 |
2 | 7 | 2013.56 | 40 | 14.60 | 3424 | 2000 | 2.24 / 73.32 | 15 | 57 |
3 | 13 | 1709.68 | 20 | 14.68 | 2993 | 879 | 3.12 / 74.20 | 5 | 65 |
4 | 13 | 1293.80 | 20 | 14.76 | 2356 | 695 | 3.81 / 74.89 | 5 | 72 |
5 | 13 | 615.68 | 20 | 14.99 | 1308 | 392 | 4.21 / 75.29 | 5 | 75 |
6 | 13 | 170.76 | 20 | 15.16 | 629 | 191 | 4.40 / 75.48 | 5 | 83 |
7 | 13 | 36.88 | 20 | 15.21 | 406 | 124 | 4.52 / 75.60 | 5 | 72 |
8 | 8 | -0.16 | 238 | 15.17 | 323 | 1166 | 5.69 / 76.77 | 5 | 152 |
Average= | 5.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.72 | 33 | 15.16 | 473 | 237 | 0.24 / 65.39 | 5 | 15 |
2 | 7 | 2019.40 | 40 | 14.60 | 3424 | 2000 | 2.24 / 67.39 | 15 | 57 |
3 | 13 | 1940.60 | 20 | 14.62 | 3306 | 967 | 3.20 / 68.36 | 5 | 61 |
4 | 13 | 1377.88 | 20 | 14.74 | 2492 | 735 | 3.94 / 69.09 | 5 | 72 |
5 | 13 | 985.16 | 20 | 14.84 | 1894 | 562 | 4.50 / 69.65 | 5 | 78 |
6 | 13 | 100.24 | 20 | 15.19 | 513 | 156 | 4.66 / 69.81 | 5 | 81 |
7 | 13 | 54.80 | 20 | 15.20 | 439 | 133 | 4.79 / 69.94 | 5 | 76 |
8 | 8 | -0.24 | 229 | 15.16 | 328 | 1139 | 5.93 / 71.08 | 5 | 143 |
Average= | 5.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.68 | 33 | 15.16 | 470 | 235 | 0.24 / 59.36 | 5 | 14 |
2 | 3 | 967.04 | -1 | 15.53 | 0 | 0 | 0.00 / 59.36 | 5 | 14 |
3 | 7 | 2007.32 | 40 | 14.69 | 3108 | 1826 | 2.06 / 61.19 | 14 | 48 |
4 | 13 | 1920.28 | 20 | 14.70 | 2987 | 878 | 2.94 / 62.07 | 5 | 54 |
5 | 13 | 1718.92 | 20 | 14.71 | 2686 | 790 | 3.73 / 62.86 | 5 | 58 |
6 | 13 | 1022.40 | 20 | 14.91 | 1619 | 483 | 4.21 / 63.34 | 5 | 41 |
7 | 13 | 357.88 | 20 | 15.12 | 790 | 239 | 4.45 / 63.58 | 5 | 52 |
8 | 13 | 89.72 | 20 | 15.20 | 475 | 144 | 4.60 / 63.72 | 5 | 63 |
9 | 8 | -0.08 | 297 | 15.17 | 317 | 1428 | 6.02 / 65.15 | 5 | 138 |
Average= | 5.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.24 | 45 | 15.16 | 473 | 323 | 0.32 / 53.39 | 5 | 16 |
2 | 3 | 641.48 | -6 | 15.54 | 0 | 0 | 0.00 / 53.39 | 5 | 16 |
3 | 7 | 2005.16 | 40 | 14.67 | 3228 | 1894 | 2.22 / 55.28 | 16 | 52 |
4 | 13 | 1937.80 | 20 | 14.70 | 3061 | 900 | 3.12 / 56.18 | 5 | 54 |
5 | 13 | 1067.60 | 20 | 14.93 | 1681 | 502 | 3.62 / 56.69 | 5 | 47 |
6 | 13 | 975.40 | 20 | 14.96 | 1492 | 446 | 4.07 / 57.13 | 5 | 57 |
7 | 13 | 142.72 | 20 | 15.21 | 499 | 152 | 4.22 / 57.28 | 5 | 52 |
8 | 13 | 88.60 | 20 | 15.21 | 458 | 139 | 4.36 / 57.42 | 5 | 54 |
9 | 8 | -0.08 | 376 | 15.17 | 299 | 1705 | 6.06 / 59.13 | 5 | 156 |
Average= | 5.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.72 | 33 | 15.18 | 417 | 209 | 0.21 / 47.11 | 5 | 8 |
2 | 10 | 1040.56 | 4 | 15.10 | 1517 | 92 | 0.30 / 47.20 | 5 | 23 |
3 | 10 | 1082.64 | 4 | 15.14 | 1444 | 87 | 0.39 / 47.29 | 5 | 23 |
4 | 10 | 1120.00 | 3 | 15.00 | 2108 | 95 | 0.48 / 47.39 | 5 | 43 |
5 | 3 | 1083.92 | 2 | 15.06 | 2035 | 61 | 0.54 / 47.45 | 5 | 33 |
6 | 7 | 2011.48 | 40 | 14.65 | 3292 | 1929 | 2.47 / 49.38 | 33 | 55 |
7 | 13 | 1816.36 | 20 | 14.71 | 2986 | 878 | 3.35 / 50.26 | 5 | 59 |
8 | 13 | 1505.28 | 20 | 14.76 | 2445 | 722 | 4.07 / 50.98 | 5 | 59 |
9 | 13 | 736.00 | 20 | 15.00 | 1344 | 403 | 4.48 / 51.38 | 5 | 57 |
10 | 13 | 125.28 | 20 | 15.20 | 530 | 161 | 4.64 / 51.54 | 5 | 67 |
11 | 13 | 76.40 | 20 | 15.21 | 478 | 145 | 4.78 / 51.69 | 5 | 75 |
12 | 8 | -0.04 | 285 | 15.18 | 319 | 1380 | 6.16 / 53.07 | 5 | 163 |
Average= | 5.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.68 | 33 | 15.18 | 454 | 227 | 0.23 / 40.49 | 5 | 17 |
2 | 7 | 2014.76 | 40 | 14.96 | 2265 | 1355 | 1.58 / 41.85 | 17 | 10 |
3 | 13 | 1966.24 | 20 | 15.03 | 1720 | 517 | 2.10 / 42.37 | 5 | 8 |
4 | 13 | 1907.92 | 20 | 15.10 | 1467 | 443 | 2.54 / 42.81 | 5 | 6 |
5 | 13 | 1834.84 | 20 | 15.18 | 899 | 273 | 2.82 / 43.08 | 5 | 5 |
6 | 13 | 1753.92 | 20 | 15.11 | 1155 | 349 | 3.16 / 43.43 | 5 | 5 |
7 | 13 | 1673.64 | 20 | 15.10 | 1014 | 306 | 3.47 / 43.74 | 5 | 5 |
8 | 13 | 1245.64 | 20 | 15.16 | 768 | 233 | 3.70 / 43.97 | 5 | 6 |
9 | 13 | 1168.72 | 20 | 15.09 | 978 | 295 | 4.00 / 44.26 | 5 | 7 |
10 | 13 | 1077.48 | 20 | 15.08 | 937 | 283 | 4.28 / 44.55 | 5 | 11 |
11 | 13 | 776.44 | 20 | 15.08 | 873 | 263 | 4.54 / 44.81 | 5 | 8 |
12 | 13 | 686.92 | 20 | 15.08 | 836 | 252 | 4.80 / 45.06 | 5 | 13 |
13 | 13 | 492.80 | 20 | 15.12 | 671 | 203 | 5.00 / 45.27 | 5 | 29 |
14 | 13 | 189.12 | 20 | 15.19 | 403 | 122 | 5.12 / 45.39 | 5 | 5 |
15 | 13 | 97.64 | 20 | 15.19 | 410 | 125 | 5.25 / 45.51 | 5 | 28 |
16 | 13 | 56.36 | 20 | 15.20 | 369 | 112 | 5.36 / 45.63 | 5 | 12 |
17 | 13 | 31.20 | 20 | 15.19 | 359 | 109 | 5.47 / 45.73 | 5 | 24 |
18 | 8 | -0.12 | 260 | 15.15 | 297 | 1170 | 6.64 / 46.90 | 5 | 39 |
Average= | 5.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.32 | 32 | 15.17 | 454 | 220 | 0.22 / 34.71 | 5 | 21 |
2 | 3 | 1042.72 | 1 | 15.15 | 1973 | 30 | 0.25 / 34.74 | 5 | 14 |
3 | 7 | 2006.12 | 41 | 14.64 | 3361 | 2017 | 2.27 / 36.76 | 14 | 57 |
4 | 13 | 1697.24 | 20 | 14.71 | 2951 | 868 | 3.14 / 37.62 | 5 | 66 |
5 | 13 | 1604.72 | 20 | 14.69 | 2808 | 825 | 3.96 / 38.45 | 5 | 69 |
6 | 13 | 683.92 | 20 | 14.98 | 1426 | 427 | 4.39 / 38.88 | 5 | 82 |
7 | 13 | 68.80 | 20 | 15.22 | 453 | 138 | 4.53 / 39.01 | 5 | 80 |
8 | 8 | -0.28 | 265 | 15.19 | 311 | 1252 | 5.78 / 40.27 | 5 | 171 |
Average= | 5.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.96 | 31 | 15.16 | 506 | 238 | 0.24 / 28.15 | 5 | 18 |
2 | 10 | 1003.40 | 3 | 15.06 | 1904 | 86 | 0.32 / 28.24 | 5 | 43 |
3 | 7 | 2008.28 | 40 | 14.94 | 2309 | 1380 | 1.70 / 29.62 | 43 | 11 |
4 | 13 | 1951.28 | 20 | 15.08 | 1763 | 532 | 2.24 / 30.15 | 5 | 12 |
5 | 13 | 1870.72 | 20 | 15.07 | 1594 | 480 | 2.72 / 30.63 | 5 | 7 |
6 | 13 | 1671.56 | 20 | 15.06 | 1564 | 471 | 3.19 / 31.10 | 5 | 8 |
7 | 13 | 1274.40 | 20 | 15.11 | 1075 | 325 | 3.51 / 31.42 | 5 | 8 |
8 | 13 | 1189.84 | 20 | 15.09 | 1027 | 310 | 3.82 / 31.73 | 5 | 17 |
9 | 13 | 1094.84 | 20 | 15.08 | 1037 | 313 | 4.13 / 32.05 | 5 | 6 |
10 | 13 | 1008.40 | 20 | 15.09 | 848 | 256 | 4.39 / 32.30 | 5 | 7 |
11 | 13 | 912.80 | 20 | 15.06 | 962 | 290 | 4.68 / 32.59 | 5 | 24 |
12 | 13 | 583.08 | 20 | 15.15 | 540 | 164 | 4.84 / 32.76 | 5 | 5 |
13 | 13 | 488.12 | 20 | 15.13 | 580 | 176 | 5.02 / 32.93 | 5 | 7 |
14 | 13 | 45.12 | 20 | 15.22 | 344 | 105 | 5.12 / 33.04 | 5 | 12 |
15 | 13 | 36.04 | 20 | 15.21 | 339 | 103 | 5.23 / 33.14 | 5 | 11 |
16 | 8 | -0.08 | 320 | 15.16 | 278 | 1349 | 6.58 / 34.49 | 5 | 59 |
Average= | 4.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.32 | 31 | 15.15 | 474 | 223 | 0.22 / 21.75 | 5 | 21 |
2 | 7 | 2006.68 | 40 | 14.64 | 3395 | 1988 | 2.21 / 23.73 | 21 | 58 |
3 | 13 | 1925.52 | 20 | 14.66 | 3281 | 962 | 3.17 / 24.70 | 5 | 61 |
4 | 13 | 1831.60 | 20 | 14.62 | 3182 | 930 | 4.10 / 25.63 | 5 | 65 |
5 | 13 | 900.08 | 20 | 14.91 | 1712 | 511 | 4.61 / 26.14 | 5 | 70 |
6 | 13 | 568.24 | 20 | 15.02 | 1217 | 366 | 4.98 / 26.50 | 5 | 76 |
7 | 13 | 23.36 | 20 | 15.22 | 391 | 119 | 5.10 / 26.62 | 5 | 83 |
8 | 8 | -0.40 | 257 | 15.17 | 331 | 1290 | 6.39 / 27.91 | 5 | 130 |
Average= | 4.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.96 | 31 | 15.16 | 492 | 231 | 0.23 / 15.90 | 5 | 17 |
2 | 7 | 1513.56 | 40 | 15.09 | 1858 | 1121 | 1.35 / 17.02 | 17 | 20 |
3 | 13 | 1490.72 | 20 | 15.12 | 1696 | 513 | 1.87 / 17.53 | 5 | 20 |
4 | 13 | 1419.56 | 20 | 15.15 | 1350 | 409 | 2.27 / 17.94 | 5 | 8 |
5 | 13 | 1346.16 | 20 | 15.09 | 1526 | 461 | 2.74 / 18.40 | 5 | 28 |
6 | 13 | 1258.36 | 20 | 15.03 | 1484 | 446 | 3.18 / 18.85 | 5 | 29 |
7 | 13 | 809.24 | 20 | 15.14 | 933 | 283 | 3.46 / 19.13 | 5 | 27 |
8 | 13 | 504.96 | 20 | 15.20 | 596 | 181 | 3.64 / 19.31 | 5 | 5 |
9 | 13 | 420.56 | 20 | 15.16 | 746 | 226 | 3.87 / 19.54 | 5 | 38 |
10 | 13 | 53.76 | 20 | 15.24 | 380 | 116 | 3.99 / 19.65 | 5 | 34 |
11 | 13 | 34.12 | 20 | 15.24 | 375 | 114 | 4.10 / 19.77 | 5 | 44 |
12 | 8 | -0.08 | 380 | 15.17 | 305 | 1758 | 5.86 / 21.52 | 5 | 55 |
Average= | 4.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.64 | 32 | 15.17 | 481 | 233 | 0.23 / 10.52 | 5 | 17 |
2 | 3 | 953.72 | -1 | 15.54 | 0 | 0 | 0.00 / 10.52 | 5 | 17 |
3 | 7 | 1510.64 | 40 | 14.86 | 2694 | 1601 | 1.83 / 12.13 | 17 | 63 |
4 | 13 | 1423.84 | 20 | 14.87 | 2532 | 753 | 2.59 / 12.88 | 5 | 63 |
5 | 13 | 1090.68 | 20 | 14.94 | 1968 | 588 | 3.18 / 13.47 | 5 | 66 |
6 | 13 | 745.24 | 20 | 15.02 | 1423 | 427 | 3.60 / 13.89 | 5 | 63 |
7 | 13 | 42.88 | 20 | 15.24 | 433 | 132 | 3.74 / 14.03 | 5 | 78 |
8 | 8 | -0.12 | 327 | 15.18 | 330 | 1638 | 5.37 / 15.66 | 5 | 158 |
Average= | 3.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.60 | 31 | 15.16 | 486 | 228 | 0.23 / 5.52 | 5 | 16 |
2 | 10 | 1021.56 | 3 | 15.09 | 1954 | 88 | 0.32 / 5.61 | 5 | 45 |
3 | 7 | 1488.16 | 40 | 14.88 | 2610 | 1553 | 1.87 / 7.16 | 45 | 62 |
4 | 13 | 1418.40 | 20 | 14.87 | 2537 | 755 | 2.62 / 7.92 | 5 | 65 |
5 | 13 | 1008.76 | 20 | 14.93 | 1927 | 575 | 3.20 / 8.49 | 5 | 73 |
6 | 13 | 575.60 | 20 | 15.05 | 1233 | 371 | 3.57 / 8.86 | 5 | 67 |
7 | 13 | 54.32 | 20 | 15.23 | 446 | 136 | 3.71 / 9.00 | 5 | 77 |
8 | 8 | -0.16 | 263 | 15.19 | 323 | 1290 | 5.00 / 10.29 | 5 | 130 |
Average= | 3.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.04 | 31 | 15.39 | 442 | 211 | 0.21 / 1.89 | 5 | 12 |
2 | 7 | 964.48 | 40 | 15.18 | 1277 | 775 | 0.99 / 2.66 | 12 | 29 |
3 | 13 | 773.56 | 20 | 15.22 | 1079 | 328 | 1.31 / 2.99 | 5 | 38 |
4 | 13 | 385.72 | 20 | 15.24 | 678 | 207 | 1.52 / 3.20 | 5 | 28 |
5 | 13 | 67.84 | 20 | 15.28 | 416 | 127 | 1.65 / 3.33 | 5 | 42 |
6 | 13 | 52.56 | 20 | 15.28 | 401 | 123 | 1.77 / 3.45 | 5 | 41 |
7 | 8 | 0.00 | 400 | 15.21 | 303 | 1843 | 3.61 / 5.29 | 5 | 90 |
Average= | 2.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 59.32 | 30 | 15.57 | 381 | 178 | 0.18 / 0.18 | 5 | 15 |
2 | 7 | 70.16 | 40 | 15.55 | 393 | 244 | 0.42 / 0.42 | 15 | 20 |
3 | 13 | 58.24 | 20 | 15.53 | 379 | 118 | 0.54 / 0.54 | 5 | 22 |
4 | 13 | 45.84 | 20 | 15.52 | 360 | 112 | 0.65 / 0.65 | 5 | 24 |
5 | 8 | 0.24 | 244 | 15.47 | 272 | 1027 | 1.68 / 1.68 | 5 | 149 |
Average= | 1.68 (KJ/cycle) |