SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.12 | 34 | 14.84 | 468 | 236 | 0.24 / 607.43 | 5 | 27 |
2 | 7 | 2005.44 | 40 | 14.56 | 3499 | 2038 | 2.27 / 609.46 | 21 | 73 |
3 | 13 | 1922.12 | 20 | 14.54 | 3368 | 979 | 3.25 / 610.44 | 5 | 78 |
4 | 13 | 1386.60 | 20 | 14.56 | 2548 | 742 | 4.00 / 611.19 | 5 | 85 |
5 | 13 | 848.44 | 20 | 14.62 | 1747 | 511 | 4.51 / 611.70 | 5 | 98 |
6 | 13 | 82.56 | 20 | 14.86 | 496 | 147 | 4.65 / 611.84 | 5 | 93 |
7 | 8 | 0.20 | 197 | 14.85 | 326 | 954 | 5.61 / 612.80 | 5 | 130 |
8 | 14 | -0.04 | 3 | 14.82 | 325 | 14 | 5.62 / 612.81 | 41 | 109 |
Average= | 5.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.04 | 34 | 14.85 | 498 | 251 | 0.25 / 601.65 | 5 | 27 |
2 | 7 | 2007.84 | 40 | 14.55 | 3513 | 2045 | 2.30 / 603.70 | 27 | 72 |
3 | 13 | 1921.40 | 20 | 14.54 | 3407 | 991 | 3.29 / 604.69 | 5 | 77 |
4 | 13 | 1292.96 | 20 | 14.58 | 2419 | 705 | 3.99 / 605.39 | 5 | 88 |
5 | 13 | 983.80 | 20 | 14.58 | 1965 | 573 | 4.57 / 605.97 | 5 | 95 |
6 | 13 | 285.12 | 20 | 14.77 | 856 | 253 | 4.82 / 606.22 | 5 | 99 |
7 | 8 | 0.12 | 199 | 14.83 | 327 | 965 | 5.78 / 607.19 | 5 | 134 |
8 | 14 | 0.00 | 1 | 14.80 | 322 | 5 | 5.79 / 607.19 | 47 | 115 |
Average= | 5.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.16 | 34 | 14.84 | 477 | 241 | 0.24 / 595.84 | 5 | 27 |
2 | 7 | 2007.76 | 41 | 14.57 | 3492 | 2086 | 2.33 / 597.93 | 27 | 73 |
3 | 13 | 1931.36 | 20 | 14.53 | 3424 | 995 | 3.32 / 598.93 | 5 | 77 |
4 | 13 | 1492.44 | 20 | 14.54 | 2730 | 794 | 4.12 / 599.72 | 5 | 85 |
5 | 13 | 730.80 | 20 | 14.66 | 1559 | 457 | 4.57 / 600.18 | 5 | 97 |
6 | 13 | 51.48 | 20 | 14.88 | 433 | 129 | 4.70 / 600.31 | 5 | 88 |
7 | 13 | 29.00 | 20 | 14.88 | 395 | 118 | 4.82 / 600.42 | 5 | 89 |
8 | 8 | 0.04 | 176 | 14.84 | 332 | 867 | 5.69 / 601.29 | 5 | 131 |
9 | 14 | 0.08 | 24 | 14.80 | 317 | 113 | 5.80 / 601.40 | 37 | -99 |
Average= | 5.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.56 | 34 | 14.85 | 494 | 249 | 0.25 / 590.03 | 5 | 29 |
2 | 7 | 2014.20 | 40 | 14.56 | 3511 | 2045 | 2.29 / 592.08 | 29 | 72 |
3 | 13 | 1920.24 | 20 | 14.54 | 3382 | 983 | 3.28 / 593.06 | 5 | 75 |
4 | 13 | 1291.96 | 20 | 14.57 | 2411 | 703 | 3.98 / 593.76 | 5 | 88 |
5 | 13 | 982.32 | 20 | 14.59 | 1951 | 569 | 4.55 / 594.33 | 5 | 94 |
6 | 13 | 102.20 | 20 | 14.85 | 532 | 158 | 4.71 / 594.49 | 5 | 92 |
7 | 13 | 54.28 | 20 | 14.86 | 442 | 131 | 4.84 / 594.62 | 5 | 90 |
8 | 8 | 0.04 | 178 | 14.83 | 332 | 876 | 5.72 / 595.50 | 5 | 139 |
9 | 14 | -0.04 | 22 | 14.80 | 323 | 105 | 5.82 / 595.60 | 33 | -99 |
Average= | 5.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.76 | 33 | 14.85 | 479 | 235 | 0.23 / 584.40 | 5 | 27 |
2 | 7 | 2004.72 | 40 | 14.57 | 3496 | 2037 | 2.27 / 586.44 | 27 | 73 |
3 | 13 | 1914.04 | 20 | 14.54 | 3384 | 984 | 3.26 / 587.42 | 5 | 76 |
4 | 13 | 1380.52 | 20 | 14.57 | 2549 | 743 | 4.00 / 588.16 | 5 | 86 |
5 | 13 | 756.72 | 20 | 14.65 | 1593 | 467 | 4.47 / 588.63 | 5 | 97 |
6 | 13 | 95.92 | 20 | 14.85 | 530 | 157 | 4.62 / 588.79 | 5 | 93 |
7 | 8 | 0.04 | 188 | 14.84 | 335 | 935 | 5.56 / 589.72 | 5 | 134 |
8 | 14 | -0.04 | 12 | 14.81 | 335 | 60 | 5.62 / 589.78 | 22 | 133 |
Average= | 5.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.44 | 33 | 14.85 | 470 | 230 | 0.23 / 578.53 | 5 | 31 |
2 | 7 | 2006.64 | 40 | 14.57 | 3505 | 2043 | 2.27 / 580.57 | 31 | 72 |
3 | 13 | 1917.44 | 20 | 14.55 | 3384 | 985 | 3.26 / 581.56 | 5 | 76 |
4 | 13 | 1603.84 | 20 | 14.52 | 2901 | 842 | 4.10 / 582.40 | 5 | 81 |
5 | 13 | 824.96 | 20 | 14.64 | 1704 | 499 | 4.60 / 582.90 | 5 | 97 |
6 | 13 | 149.84 | 20 | 14.84 | 611 | 181 | 4.78 / 583.08 | 5 | 97 |
7 | 13 | 30.40 | 20 | 14.87 | 394 | 117 | 4.90 / 583.20 | 5 | 91 |
8 | 8 | 0.00 | 178 | 14.84 | 328 | 866 | 5.76 / 584.06 | 5 | 132 |
9 | 14 | -0.04 | 22 | 14.80 | 319 | 104 | 5.87 / 584.17 | 48 | -99 |
Average= | 5.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.32 | 33 | 14.85 | 501 | 246 | 0.25 / 572.96 | 5 | 29 |
2 | 7 | 2006.44 | 40 | 14.57 | 3480 | 2028 | 2.27 / 574.99 | 29 | 73 |
3 | 13 | 1910.96 | 20 | 14.54 | 3387 | 985 | 3.26 / 575.98 | 5 | 77 |
4 | 13 | 1262.40 | 20 | 14.59 | 2381 | 695 | 3.95 / 576.67 | 5 | 87 |
5 | 13 | 839.60 | 20 | 14.63 | 1733 | 507 | 4.46 / 577.18 | 5 | 98 |
6 | 13 | 88.88 | 20 | 14.86 | 502 | 149 | 4.61 / 577.33 | 5 | 91 |
7 | 8 | 0.12 | 193 | 14.85 | 327 | 937 | 5.55 / 578.26 | 5 | 135 |
8 | 14 | 0.00 | 7 | 14.81 | 326 | 34 | 5.58 / 578.30 | 35 | 134 |
Average= | 5.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.32 | 33 | 14.86 | 487 | 239 | 0.24 / 567.23 | 5 | 27 |
2 | 7 | 2008.04 | 41 | 14.56 | 3489 | 2083 | 2.32 / 569.32 | 27 | 73 |
3 | 13 | 1814.04 | 20 | 14.55 | 3227 | 939 | 3.26 / 570.25 | 5 | 79 |
4 | 13 | 1292.96 | 20 | 14.58 | 2432 | 709 | 3.97 / 570.96 | 5 | 86 |
5 | 13 | 864.28 | 20 | 14.62 | 1777 | 520 | 4.49 / 571.48 | 5 | 96 |
6 | 13 | 85.32 | 20 | 14.85 | 506 | 150 | 4.64 / 571.63 | 5 | 91 |
7 | 13 | 22.00 | 20 | 14.87 | 379 | 113 | 4.75 / 571.75 | 5 | 90 |
8 | 8 | 0.08 | 165 | 14.84 | 329 | 806 | 5.56 / 572.55 | 5 | 129 |
9 | 14 | -0.08 | 35 | 14.80 | 319 | 165 | 5.72 / 572.72 | 24 | -99 |
Average= | 5.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.32 | 33 | 14.84 | 476 | 233 | 0.23 / 561.51 | 5 | 31 |
2 | 7 | 2007.72 | 40 | 14.57 | 3493 | 2036 | 2.27 / 563.55 | 31 | 72 |
3 | 13 | 1920.36 | 20 | 14.55 | 3399 | 989 | 3.26 / 564.54 | 5 | 78 |
4 | 13 | 1298.88 | 20 | 14.59 | 2418 | 706 | 3.96 / 565.24 | 5 | 88 |
5 | 13 | 866.92 | 20 | 14.63 | 1763 | 516 | 4.48 / 565.76 | 5 | 98 |
6 | 13 | 63.72 | 20 | 14.88 | 461 | 137 | 4.62 / 565.90 | 5 | 91 |
7 | 13 | 16.52 | 20 | 14.89 | 368 | 110 | 4.73 / 566.01 | 5 | 88 |
8 | 8 | 0.08 | 176 | 14.85 | 334 | 873 | 5.60 / 566.88 | 5 | 133 |
9 | 14 | -0.08 | 24 | 14.81 | 322 | 114 | 5.71 / 566.99 | 37 | -99 |
Average= | 5.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.52 | 33 | 14.85 | 492 | 241 | 0.24 / 555.60 | 5 | 31 |
2 | 7 | 2003.80 | 40 | 14.58 | 3477 | 2028 | 2.27 / 557.62 | 31 | 72 |
3 | 13 | 1912.44 | 20 | 14.56 | 3375 | 983 | 3.25 / 558.61 | 5 | 76 |
4 | 13 | 1485.56 | 20 | 14.55 | 2712 | 789 | 4.04 / 559.40 | 5 | 85 |
5 | 13 | 928.72 | 20 | 14.61 | 1871 | 547 | 4.59 / 559.94 | 5 | 94 |
6 | 13 | 255.40 | 20 | 14.80 | 798 | 236 | 4.82 / 560.18 | 5 | 99 |
7 | 13 | 27.28 | 20 | 14.87 | 396 | 118 | 4.94 / 560.30 | 5 | 93 |
8 | 8 | 0.04 | 178 | 14.84 | 332 | 877 | 5.82 / 561.17 | 5 | 135 |
9 | 14 | 0.00 | 22 | 14.80 | 326 | 106 | 5.92 / 561.28 | 34 | -99 |
Average= | 5.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.68 | 33 | 14.87 | 479 | 235 | 0.24 / 549.96 | 5 | 29 |
2 | 7 | 2009.08 | 40 | 14.57 | 3482 | 2029 | 2.26 / 551.99 | 29 | 71 |
3 | 13 | 1925.12 | 20 | 14.55 | 3382 | 984 | 3.25 / 552.97 | 5 | 77 |
4 | 13 | 1295.00 | 20 | 14.59 | 2384 | 696 | 3.94 / 553.67 | 5 | 90 |
5 | 13 | 766.12 | 20 | 14.66 | 1607 | 471 | 4.42 / 554.14 | 5 | 98 |
6 | 13 | 121.52 | 20 | 14.86 | 552 | 164 | 4.58 / 554.30 | 5 | 92 |
7 | 13 | 24.48 | 20 | 14.88 | 371 | 110 | 4.69 / 554.41 | 5 | 92 |
8 | 8 | 0.12 | 174 | 14.85 | 319 | 824 | 5.51 / 555.24 | 5 | 131 |
9 | 14 | -0.04 | 26 | 14.82 | 309 | 119 | 5.63 / 555.36 | 34 | -99 |
Average= | 5.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.20 | 33 | 14.85 | 500 | 245 | 0.25 / 544.11 | 5 | 35 |
2 | 7 | 2003.44 | 40 | 14.58 | 3488 | 2034 | 2.28 / 546.15 | 35 | 74 |
3 | 13 | 1904.56 | 20 | 14.56 | 3352 | 976 | 3.26 / 547.12 | 5 | 77 |
4 | 13 | 1693.20 | 20 | 14.53 | 3029 | 880 | 4.14 / 548.00 | 5 | 82 |
5 | 13 | 905.92 | 20 | 14.63 | 1832 | 536 | 4.67 / 548.54 | 5 | 96 |
6 | 13 | 234.76 | 20 | 14.82 | 749 | 222 | 4.89 / 548.76 | 5 | 98 |
7 | 8 | 0.12 | 197 | 14.86 | 324 | 948 | 5.84 / 549.71 | 5 | 130 |
8 | 14 | -0.08 | 3 | 14.83 | 313 | 14 | 5.86 / 549.72 | 38 | 98 |
Average= | 5.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.36 | 33 | 14.85 | 499 | 245 | 0.24 / 538.42 | 5 | 35 |
2 | 7 | 2010.36 | 41 | 14.58 | 3499 | 2092 | 2.34 / 540.51 | 35 | 72 |
3 | 13 | 1926.96 | 20 | 14.56 | 3407 | 992 | 3.33 / 541.51 | 5 | 79 |
4 | 13 | 1378.00 | 20 | 14.57 | 2551 | 743 | 4.07 / 542.25 | 5 | 86 |
5 | 13 | 725.12 | 20 | 14.68 | 1541 | 452 | 4.52 / 542.70 | 5 | 98 |
6 | 13 | 165.00 | 20 | 14.85 | 632 | 188 | 4.71 / 542.89 | 5 | 96 |
7 | 8 | 0.08 | 193 | 14.86 | 329 | 944 | 5.66 / 543.83 | 5 | 129 |
8 | 14 | -0.08 | 7 | 14.82 | 327 | 34 | 5.69 / 543.87 | 34 | 127 |
Average= | 5.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.84 | 34 | 14.86 | 484 | 245 | 0.24 / 532.76 | 5 | 35 |
2 | 7 | 2015.08 | 40 | 14.58 | 3497 | 2039 | 2.28 / 534.80 | 35 | 74 |
3 | 13 | 1920.20 | 20 | 14.56 | 3389 | 987 | 3.27 / 535.78 | 5 | 78 |
4 | 13 | 1365.20 | 20 | 14.58 | 2531 | 738 | 4.01 / 536.52 | 5 | 88 |
5 | 13 | 709.56 | 20 | 14.68 | 1513 | 444 | 4.45 / 536.97 | 5 | 100 |
6 | 13 | 91.12 | 20 | 14.88 | 499 | 149 | 4.60 / 537.11 | 5 | 94 |
7 | 13 | 18.84 | 20 | 14.89 | 366 | 109 | 4.71 / 537.22 | 5 | 92 |
8 | 8 | 0.12 | 178 | 14.86 | 322 | 852 | 5.56 / 538.07 | 5 | 138 |
9 | 14 | -0.04 | 22 | 14.82 | 315 | 103 | 5.67 / 538.18 | 34 | -99 |
Average= | 5.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.88 | 33 | 14.85 | 498 | 244 | 0.24 / 527.14 | 5 | 33 |
2 | 7 | 2005.80 | 40 | 14.59 | 3478 | 2030 | 2.27 / 529.17 | 16 | 73 |
3 | 13 | 1908.80 | 20 | 14.56 | 3364 | 980 | 3.25 / 530.15 | 5 | 79 |
4 | 13 | 1380.16 | 20 | 14.58 | 2541 | 741 | 3.99 / 530.89 | 5 | 88 |
5 | 13 | 860.48 | 20 | 14.64 | 1757 | 514 | 4.51 / 531.41 | 5 | 98 |
6 | 13 | 43.20 | 20 | 14.89 | 422 | 126 | 4.63 / 531.53 | 5 | 92 |
7 | 8 | 0.20 | 197 | 14.86 | 330 | 966 | 5.60 / 532.50 | 5 | 129 |
8 | 14 | 0.00 | 3 | 14.83 | 318 | 14 | 5.61 / 532.51 | 35 | 111 |
Average= | 5.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.40 | 33 | 14.86 | 488 | 239 | 0.24 / 521.41 | 5 | 29 |
2 | 7 | 2003.60 | 41 | 14.58 | 3481 | 2081 | 2.32 / 523.49 | 29 | 73 |
3 | 13 | 1909.56 | 20 | 14.55 | 3400 | 989 | 3.31 / 524.48 | 5 | 77 |
4 | 13 | 1373.12 | 20 | 14.58 | 2541 | 741 | 4.05 / 525.22 | 5 | 85 |
5 | 13 | 835.44 | 20 | 14.65 | 1722 | 505 | 4.56 / 525.73 | 5 | 97 |
6 | 13 | 166.36 | 20 | 14.84 | 648 | 192 | 4.75 / 525.92 | 5 | 96 |
7 | 8 | 0.12 | 195 | 14.85 | 330 | 956 | 5.70 / 526.87 | 5 | 129 |
8 | 14 | 0.00 | 5 | 14.82 | 327 | 24 | 5.73 / 526.90 | 28 | 132 |
Average= | 5.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.96 | 33 | 14.86 | 488 | 239 | 0.24 / 515.58 | 5 | 27 |
2 | 7 | 2014.88 | 40 | 14.58 | 3523 | 2055 | 2.29 / 517.63 | 27 | 73 |
3 | 13 | 1925.44 | 20 | 14.56 | 3403 | 991 | 3.28 / 518.62 | 5 | 78 |
4 | 13 | 1391.32 | 20 | 14.58 | 2579 | 752 | 4.04 / 519.37 | 5 | 86 |
5 | 13 | 835.44 | 20 | 14.65 | 1728 | 506 | 4.54 / 519.88 | 5 | 97 |
6 | 13 | 177.00 | 20 | 14.84 | 666 | 198 | 4.74 / 520.08 | 5 | 96 |
7 | 13 | 14.28 | 20 | 14.89 | 370 | 110 | 4.85 / 520.19 | 5 | 91 |
8 | 8 | 0.20 | 178 | 14.85 | 332 | 878 | 5.73 / 521.06 | 5 | 141 |
9 | 14 | -0.04 | 22 | 14.82 | 324 | 106 | 5.83 / 521.17 | 42 | -99 |
Average= | 5.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.76 | 33 | 14.86 | 484 | 237 | 0.24 / 509.85 | 5 | 28 |
2 | 7 | 2005.64 | 40 | 14.59 | 3495 | 2040 | 2.28 / 511.89 | 28 | 73 |
3 | 13 | 1917.96 | 20 | 14.56 | 3389 | 987 | 3.26 / 512.88 | 5 | 78 |
4 | 13 | 1383.56 | 20 | 14.59 | 2560 | 747 | 4.01 / 513.63 | 5 | 85 |
5 | 13 | 843.32 | 20 | 14.65 | 1730 | 507 | 4.52 / 514.13 | 5 | 97 |
6 | 13 | 82.72 | 20 | 14.88 | 484 | 144 | 4.66 / 514.28 | 5 | 91 |
7 | 13 | 17.68 | 20 | 14.90 | 367 | 109 | 4.77 / 514.39 | 5 | 93 |
8 | 8 | 0.16 | 173 | 14.86 | 321 | 825 | 5.60 / 515.21 | 5 | 132 |
9 | 14 | 0.08 | 27 | 14.83 | 313 | 125 | 5.72 / 515.34 | 28 | -99 |
Average= | 5.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.36 | 34 | 14.87 | 480 | 243 | 0.24 / 504.06 | 5 | 26 |
2 | 7 | 2012.96 | 40 | 14.59 | 3494 | 2039 | 2.28 / 506.10 | 26 | 71 |
3 | 13 | 1923.68 | 20 | 14.57 | 3402 | 991 | 3.27 / 507.09 | 5 | 76 |
4 | 13 | 1371.24 | 20 | 14.59 | 2531 | 739 | 4.01 / 507.83 | 5 | 86 |
5 | 13 | 820.56 | 20 | 14.66 | 1701 | 499 | 4.51 / 508.33 | 5 | 98 |
6 | 13 | 155.60 | 20 | 14.85 | 629 | 187 | 4.70 / 508.51 | 5 | 95 |
7 | 13 | 13.68 | 20 | 14.89 | 368 | 110 | 4.81 / 508.62 | 5 | 92 |
8 | 8 | 0.20 | 178 | 14.85 | 335 | 886 | 5.69 / 509.51 | 5 | 134 |
9 | 14 | 0.04 | 22 | 14.82 | 324 | 106 | 5.80 / 509.61 | 36 | -99 |
Average= | 5.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.08 | 34 | 14.86 | 482 | 244 | 0.24 / 498.28 | 5 | 22 |
2 | 7 | 2007.80 | 40 | 14.59 | 3494 | 2039 | 2.28 / 500.32 | 22 | 72 |
3 | 13 | 1923.80 | 20 | 14.57 | 3402 | 991 | 3.27 / 501.31 | 5 | 77 |
4 | 13 | 1410.44 | 20 | 14.58 | 2598 | 758 | 4.03 / 502.06 | 5 | 85 |
5 | 13 | 856.28 | 20 | 14.64 | 1768 | 518 | 4.55 / 502.58 | 5 | 96 |
6 | 13 | 97.60 | 20 | 14.87 | 520 | 155 | 4.70 / 502.74 | 5 | 93 |
7 | 13 | 23.56 | 20 | 14.89 | 379 | 113 | 4.82 / 502.85 | 5 | 93 |
8 | 8 | 0.12 | 180 | 14.86 | 326 | 872 | 5.69 / 503.72 | 5 | 130 |
9 | 14 | 0.00 | 20 | 14.82 | 318 | 94 | 5.78 / 503.82 | 41 | -99 |
Average= | 5.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.04 | 34 | 14.86 | 479 | 242 | 0.24 / 492.40 | 5 | 20 |
2 | 7 | 2007.40 | 40 | 14.59 | 3488 | 2036 | 2.28 / 494.44 | 17 | 72 |
3 | 13 | 1916.24 | 20 | 14.57 | 3390 | 988 | 3.27 / 495.43 | 5 | 76 |
4 | 13 | 1482.56 | 20 | 14.57 | 2724 | 794 | 4.06 / 496.22 | 5 | 83 |
5 | 13 | 815.56 | 20 | 14.66 | 1695 | 497 | 4.56 / 496.72 | 5 | 98 |
6 | 13 | 255.12 | 20 | 14.81 | 791 | 234 | 4.79 / 496.95 | 5 | 99 |
7 | 13 | 26.88 | 20 | 14.88 | 393 | 117 | 4.91 / 497.07 | 5 | 93 |
8 | 8 | 0.16 | 176 | 14.85 | 326 | 852 | 5.76 / 497.92 | 5 | 129 |
9 | 14 | -0.04 | 24 | 14.81 | 317 | 113 | 5.87 / 498.03 | 37 | -99 |
Average= | 5.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.04 | 33 | 14.87 | 458 | 225 | 0.22 / 486.55 | 5 | 21 |
2 | 7 | 2008.16 | 40 | 14.59 | 3499 | 2042 | 2.27 / 488.59 | 21 | 72 |
3 | 13 | 1917.28 | 20 | 14.56 | 3396 | 989 | 3.26 / 489.58 | 5 | 77 |
4 | 13 | 1388.80 | 20 | 14.59 | 2568 | 749 | 4.01 / 490.33 | 5 | 86 |
5 | 13 | 849.00 | 20 | 14.65 | 1761 | 516 | 4.52 / 490.84 | 5 | 98 |
6 | 13 | 275.92 | 20 | 14.80 | 831 | 246 | 4.77 / 491.09 | 5 | 100 |
7 | 13 | 34.80 | 20 | 14.88 | 400 | 119 | 4.89 / 491.21 | 5 | 92 |
8 | 8 | 0.12 | 182 | 14.85 | 321 | 868 | 5.75 / 492.08 | 5 | 130 |
9 | 14 | -0.04 | 18 | 14.82 | 315 | 84 | 5.84 / 492.16 | 43 | -99 |
Average= | 5.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.68 | 33 | 14.88 | 472 | 232 | 0.23 / 480.92 | 5 | 19 |
2 | 7 | 2003.04 | 40 | 14.59 | 3481 | 2032 | 2.26 / 482.95 | 19 | 74 |
3 | 13 | 1806.16 | 20 | 14.59 | 3203 | 935 | 3.20 / 483.89 | 5 | 80 |
4 | 13 | 1287.80 | 20 | 14.60 | 2411 | 704 | 3.90 / 484.59 | 5 | 88 |
5 | 13 | 858.16 | 20 | 14.65 | 1770 | 519 | 4.42 / 485.11 | 5 | 98 |
6 | 13 | 86.96 | 20 | 14.87 | 508 | 151 | 4.57 / 485.26 | 5 | 92 |
7 | 13 | 26.20 | 20 | 14.89 | 381 | 113 | 4.69 / 485.37 | 5 | 89 |
8 | 8 | 0.12 | 178 | 14.86 | 321 | 849 | 5.53 / 486.22 | 5 | 134 |
9 | 14 | -0.04 | 22 | 14.82 | 307 | 100 | 5.63 / 486.32 | 41 | -99 |
Average= | 5.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.48 | 33 | 14.87 | 459 | 225 | 0.23 / 475.18 | 5 | 19 |
2 | 7 | 2004.60 | 40 | 14.59 | 3479 | 2030 | 2.26 / 477.21 | 19 | 73 |
3 | 13 | 1906.96 | 20 | 14.58 | 3358 | 979 | 3.23 / 478.19 | 5 | 79 |
4 | 13 | 1468.24 | 20 | 14.58 | 2695 | 786 | 4.02 / 478.97 | 5 | 86 |
5 | 13 | 904.76 | 20 | 14.64 | 1833 | 537 | 4.56 / 479.51 | 5 | 96 |
6 | 13 | 66.72 | 20 | 14.89 | 450 | 134 | 4.69 / 479.64 | 5 | 93 |
7 | 13 | 21.00 | 20 | 14.90 | 366 | 109 | 4.80 / 479.75 | 5 | 89 |
8 | 8 | 0.08 | 178 | 14.87 | 317 | 839 | 5.64 / 480.59 | 5 | 131 |
9 | 14 | -0.04 | 22 | 14.83 | 299 | 98 | 5.74 / 480.69 | 38 | -99 |
Average= | 5.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.68 | 33 | 14.88 | 459 | 225 | 0.23 / 469.41 | 5 | 20 |
2 | 7 | 2009.12 | 40 | 14.60 | 3488 | 2037 | 2.26 / 471.45 | 20 | 73 |
3 | 13 | 1922.64 | 20 | 14.57 | 3394 | 989 | 3.25 / 472.44 | 5 | 76 |
4 | 13 | 1384.20 | 20 | 14.59 | 2553 | 745 | 4.00 / 473.18 | 5 | 86 |
5 | 13 | 844.72 | 20 | 14.66 | 1739 | 510 | 4.51 / 473.69 | 5 | 98 |
6 | 13 | 177.16 | 20 | 14.85 | 654 | 194 | 4.70 / 473.88 | 5 | 96 |
7 | 13 | 34.84 | 20 | 14.89 | 397 | 118 | 4.82 / 474.00 | 5 | 93 |
8 | 8 | -0.04 | 182 | 14.86 | 320 | 865 | 5.68 / 474.87 | 5 | 132 |
9 | 14 | -0.04 | 18 | 14.83 | 314 | 84 | 5.77 / 474.95 | 39 | -99 |
Average= | 5.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.12 | 33 | 14.88 | 459 | 225 | 0.23 / 463.82 | 5 | 20 |
2 | 7 | 2004.48 | 40 | 14.60 | 3475 | 2029 | 2.25 / 465.85 | 20 | 73 |
3 | 13 | 1907.72 | 20 | 14.58 | 3361 | 980 | 3.23 / 466.83 | 5 | 78 |
4 | 13 | 1277.88 | 20 | 14.61 | 2399 | 701 | 3.94 / 467.53 | 5 | 89 |
5 | 13 | 738.80 | 20 | 14.69 | 1569 | 461 | 4.40 / 467.99 | 5 | 99 |
6 | 13 | 88.16 | 20 | 14.89 | 494 | 147 | 4.54 / 468.14 | 5 | 92 |
7 | 13 | 24.60 | 20 | 14.90 | 370 | 110 | 4.65 / 468.25 | 5 | 92 |
8 | 8 | 0.16 | 180 | 14.87 | 316 | 846 | 5.50 / 469.10 | 5 | 141 |
9 | 14 | -0.04 | 20 | 14.84 | 301 | 89 | 5.59 / 469.18 | 47 | -99 |
Average= | 5.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.72 | 33 | 14.89 | 485 | 238 | 0.24 / 458.06 | 5 | 21 |
2 | 7 | 2007.96 | 40 | 14.61 | 3497 | 2044 | 2.28 / 460.10 | 21 | 73 |
3 | 13 | 1919.88 | 20 | 14.57 | 3390 | 988 | 3.27 / 461.09 | 5 | 78 |
4 | 13 | 1487.68 | 20 | 14.58 | 2717 | 792 | 4.06 / 461.88 | 5 | 86 |
5 | 13 | 824.04 | 20 | 14.67 | 1703 | 500 | 4.56 / 462.38 | 5 | 97 |
6 | 13 | 80.92 | 20 | 14.90 | 495 | 148 | 4.71 / 462.53 | 5 | 91 |
7 | 13 | 25.44 | 20 | 14.91 | 383 | 114 | 4.82 / 462.65 | 5 | 88 |
8 | 8 | 0.20 | 182 | 14.87 | 320 | 866 | 5.69 / 463.51 | 5 | 140 |
9 | 14 | 0.00 | 18 | 14.84 | 310 | 83 | 5.77 / 463.60 | 43 | -99 |
Average= | 5.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.76 | 33 | 14.89 | 478 | 235 | 0.23 / 452.38 | 5 | 22 |
2 | 7 | 2003.72 | 40 | 14.61 | 3479 | 2033 | 2.27 / 454.41 | 22 | 73 |
3 | 13 | 1910.92 | 20 | 14.58 | 3373 | 984 | 3.25 / 455.39 | 5 | 77 |
4 | 13 | 1358.60 | 20 | 14.61 | 2514 | 735 | 3.99 / 456.13 | 5 | 85 |
5 | 13 | 827.64 | 20 | 14.67 | 1708 | 501 | 4.49 / 456.63 | 5 | 101 |
6 | 13 | 83.84 | 20 | 14.90 | 491 | 146 | 4.63 / 456.78 | 5 | 93 |
7 | 13 | 21.24 | 20 | 14.91 | 366 | 109 | 4.74 / 456.89 | 5 | 92 |
8 | 8 | 0.16 | 176 | 14.88 | 316 | 828 | 5.57 / 457.71 | 5 | 139 |
9 | 14 | 0.04 | 24 | 14.84 | 309 | 110 | 5.68 / 457.82 | 38 | -99 |
Average= | 5.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.04 | 33 | 14.88 | 485 | 238 | 0.24 / 446.76 | 5 | 24 |
2 | 7 | 2005.48 | 40 | 14.60 | 3488 | 2037 | 2.28 / 448.80 | 24 | 73 |
3 | 13 | 1813.92 | 20 | 14.60 | 3212 | 938 | 3.21 / 449.73 | 5 | 80 |
4 | 13 | 1397.60 | 20 | 14.59 | 2582 | 753 | 3.97 / 450.49 | 5 | 85 |
5 | 13 | 746.08 | 20 | 14.69 | 1574 | 462 | 4.43 / 450.95 | 5 | 98 |
6 | 13 | 51.28 | 20 | 14.91 | 429 | 128 | 4.56 / 451.08 | 5 | 89 |
7 | 13 | 11.80 | 20 | 14.92 | 358 | 107 | 4.66 / 451.19 | 5 | 89 |
8 | 8 | 0.20 | 176 | 14.88 | 323 | 846 | 5.51 / 452.03 | 5 | 138 |
9 | 14 | -0.04 | 24 | 14.84 | 313 | 111 | 5.62 / 452.14 | 37 | -99 |
Average= | 5.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.00 | 33 | 14.89 | 480 | 236 | 0.24 / 441.02 | 5 | 24 |
2 | 7 | 2006.72 | 40 | 14.61 | 3483 | 2035 | 2.27 / 443.06 | 24 | 73 |
3 | 13 | 1909.36 | 20 | 14.58 | 3368 | 982 | 3.25 / 444.04 | 5 | 77 |
4 | 13 | 1462.72 | 20 | 14.60 | 2673 | 781 | 4.03 / 444.82 | 5 | 85 |
5 | 13 | 799.88 | 20 | 14.68 | 1665 | 489 | 4.52 / 445.31 | 5 | 97 |
6 | 13 | 46.72 | 20 | 14.91 | 434 | 129 | 4.65 / 445.44 | 5 | 90 |
7 | 13 | 27.64 | 20 | 14.91 | 390 | 116 | 4.77 / 445.56 | 5 | 91 |
8 | 8 | 0.12 | 176 | 14.88 | 326 | 854 | 5.62 / 446.41 | 5 | 132 |
9 | 14 | 0.00 | 24 | 14.84 | 315 | 112 | 5.73 / 446.52 | 33 | -99 |
Average= | 5.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.56 | 33 | 14.89 | 485 | 238 | 0.24 / 435.35 | 5 | 27 |
2 | 7 | 2014.04 | 40 | 14.60 | 3493 | 2040 | 2.28 / 437.39 | 27 | 72 |
3 | 13 | 1917.48 | 20 | 14.58 | 3367 | 982 | 3.26 / 438.37 | 5 | 76 |
4 | 13 | 1382.84 | 20 | 14.61 | 2545 | 744 | 4.00 / 439.11 | 5 | 87 |
5 | 13 | 746.12 | 20 | 14.70 | 1582 | 465 | 4.47 / 439.58 | 5 | 100 |
6 | 13 | 50.20 | 20 | 14.92 | 433 | 129 | 4.60 / 439.71 | 5 | 91 |
7 | 13 | 28.08 | 20 | 14.92 | 388 | 116 | 4.71 / 439.82 | 5 | 91 |
8 | 8 | 0.12 | 178 | 14.88 | 325 | 861 | 5.57 / 440.69 | 5 | 132 |
9 | 14 | -0.04 | 22 | 14.85 | 311 | 102 | 5.68 / 440.79 | 35 | -99 |
Average= | 5.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.92 | 33 | 14.89 | 481 | 236 | 0.24 / 429.76 | 5 | 26 |
2 | 7 | 2012.60 | 40 | 14.60 | 3487 | 2036 | 2.27 / 431.79 | 18 | 71 |
3 | 13 | 1915.72 | 20 | 14.58 | 3366 | 982 | 3.25 / 432.77 | 5 | 77 |
4 | 13 | 1286.60 | 20 | 14.63 | 2392 | 700 | 3.95 / 433.47 | 5 | 89 |
5 | 13 | 673.80 | 20 | 14.72 | 1463 | 431 | 4.38 / 433.90 | 5 | 98 |
6 | 13 | 64.00 | 20 | 14.92 | 453 | 135 | 4.52 / 434.04 | 5 | 92 |
7 | 13 | 15.52 | 20 | 14.93 | 363 | 108 | 4.63 / 434.15 | 5 | 88 |
8 | 8 | 0.20 | 176 | 14.89 | 325 | 852 | 5.48 / 435.00 | 5 | 131 |
9 | 14 | 0.08 | 24 | 14.85 | 310 | 110 | 5.59 / 435.11 | 38 | -99 |
Average= | 5.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.32 | 33 | 14.89 | 464 | 228 | 0.23 / 424.10 | 5 | 25 |
2 | 7 | 2005.00 | 40 | 14.62 | 3471 | 2030 | 2.26 / 426.13 | 25 | 74 |
3 | 13 | 1914.52 | 20 | 14.60 | 3374 | 985 | 3.24 / 427.12 | 5 | 76 |
4 | 13 | 1373.92 | 20 | 14.61 | 2548 | 745 | 3.99 / 427.86 | 5 | 86 |
5 | 13 | 735.92 | 20 | 14.71 | 1563 | 460 | 4.45 / 428.32 | 5 | 99 |
6 | 13 | 47.52 | 20 | 14.92 | 425 | 127 | 4.57 / 428.45 | 5 | 89 |
7 | 13 | 13.68 | 20 | 14.93 | 361 | 108 | 4.68 / 428.56 | 5 | 91 |
8 | 8 | 0.16 | 176 | 14.89 | 325 | 852 | 5.53 / 429.41 | 5 | 133 |
9 | 14 | 0.00 | 24 | 14.86 | 310 | 111 | 5.64 / 429.52 | 35 | -99 |
Average= | 5.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.84 | 33 | 14.90 | 465 | 229 | 0.23 / 418.25 | 5 | 23 |
2 | 7 | 2009.76 | 40 | 14.61 | 3502 | 2047 | 2.28 / 420.30 | 23 | 74 |
3 | 13 | 1931.64 | 20 | 14.59 | 3386 | 988 | 3.26 / 421.29 | 5 | 77 |
4 | 13 | 1502.64 | 20 | 14.59 | 2756 | 804 | 4.07 / 422.09 | 5 | 85 |
5 | 13 | 842.00 | 20 | 14.68 | 1733 | 509 | 4.58 / 422.60 | 5 | 98 |
6 | 13 | 175.72 | 20 | 14.88 | 652 | 194 | 4.77 / 422.79 | 5 | 97 |
7 | 13 | 31.56 | 20 | 14.92 | 398 | 119 | 4.89 / 422.91 | 5 | 94 |
8 | 8 | 0.16 | 176 | 14.88 | 326 | 854 | 5.74 / 423.76 | 5 | 132 |
9 | 14 | -0.04 | 24 | 14.85 | 311 | 111 | 5.85 / 423.88 | 34 | -99 |
Average= | 5.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.56 | 33 | 14.91 | 458 | 225 | 0.23 / 412.50 | 5 | 25 |
2 | 7 | 2005.56 | 40 | 14.62 | 3483 | 2037 | 2.26 / 414.54 | 25 | 73 |
3 | 13 | 1922.04 | 20 | 14.59 | 3396 | 991 | 3.25 / 415.53 | 5 | 76 |
4 | 13 | 1489.32 | 20 | 14.60 | 2697 | 788 | 4.04 / 416.32 | 5 | 86 |
5 | 13 | 834.16 | 20 | 14.69 | 1716 | 504 | 4.54 / 416.82 | 5 | 97 |
6 | 13 | 87.76 | 20 | 14.92 | 503 | 150 | 4.69 / 416.97 | 5 | 91 |
7 | 13 | 23.76 | 20 | 14.93 | 370 | 110 | 4.81 / 417.08 | 5 | 87 |
8 | 8 | 0.12 | 178 | 14.90 | 317 | 841 | 5.65 / 417.92 | 5 | 129 |
9 | 14 | -0.04 | 22 | 14.87 | 307 | 100 | 5.75 / 418.02 | 40 | -99 |
Average= | 5.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.36 | 33 | 14.90 | 459 | 226 | 0.23 / 406.84 | 5 | 22 |
2 | 7 | 2013.20 | 40 | 14.62 | 3486 | 2039 | 2.26 / 408.88 | 22 | 73 |
3 | 13 | 1816.96 | 20 | 14.61 | 3223 | 942 | 3.21 / 409.82 | 5 | 78 |
4 | 13 | 1390.52 | 20 | 14.62 | 2556 | 747 | 3.95 / 410.56 | 5 | 85 |
5 | 13 | 854.20 | 20 | 14.68 | 1746 | 513 | 4.47 / 411.08 | 5 | 98 |
6 | 13 | 99.08 | 20 | 14.91 | 515 | 154 | 4.62 / 411.23 | 5 | 91 |
7 | 13 | 24.76 | 20 | 14.93 | 368 | 110 | 4.73 / 411.34 | 5 | 89 |
8 | 8 | 0.24 | 178 | 14.90 | 315 | 835 | 5.56 / 412.18 | 5 | 135 |
9 | 14 | 0.00 | 22 | 14.86 | 303 | 99 | 5.66 / 412.28 | 33 | -99 |
Average= | 5.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.08 | 33 | 14.91 | 482 | 237 | 0.24 / 401.20 | 5 | 25 |
2 | 7 | 2003.04 | 40 | 14.62 | 3488 | 2040 | 2.28 / 403.24 | 25 | 72 |
3 | 13 | 1816.04 | 20 | 14.61 | 3212 | 939 | 3.22 / 404.18 | 5 | 80 |
4 | 13 | 1321.00 | 20 | 14.63 | 2439 | 714 | 3.93 / 404.89 | 5 | 88 |
5 | 13 | 787.76 | 20 | 14.70 | 1644 | 483 | 4.41 / 405.38 | 5 | 98 |
6 | 13 | 122.84 | 20 | 14.91 | 562 | 168 | 4.58 / 405.55 | 5 | 94 |
7 | 13 | 26.08 | 20 | 14.93 | 381 | 114 | 4.69 / 405.66 | 5 | 91 |
8 | 8 | 0.12 | 176 | 14.90 | 321 | 842 | 5.54 / 406.50 | 5 | 132 |
9 | 14 | 0.00 | 24 | 14.86 | 309 | 110 | 5.65 / 406.61 | 36 | -99 |
Average= | 5.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.68 | 33 | 14.92 | 480 | 236 | 0.24 / 395.40 | 5 | 25 |
2 | 7 | 2007.96 | 40 | 14.62 | 3495 | 2044 | 2.28 / 397.45 | 25 | 74 |
3 | 13 | 1927.96 | 20 | 14.59 | 3391 | 989 | 3.27 / 398.44 | 5 | 77 |
4 | 13 | 1393.64 | 20 | 14.62 | 2575 | 753 | 4.02 / 399.19 | 5 | 86 |
5 | 13 | 853.84 | 20 | 14.69 | 1747 | 513 | 4.54 / 399.70 | 5 | 98 |
6 | 13 | 197.76 | 20 | 14.88 | 683 | 203 | 4.74 / 399.91 | 5 | 94 |
7 | 13 | 36.16 | 20 | 14.93 | 394 | 118 | 4.86 / 400.02 | 5 | 89 |
8 | 8 | 0.12 | 180 | 14.90 | 317 | 850 | 5.71 / 400.87 | 5 | 132 |
9 | 14 | 0.00 | 20 | 14.86 | 311 | 92 | 5.80 / 400.97 | 36 | -99 |
Average= | 5.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.36 | 33 | 14.91 | 460 | 226 | 0.23 / 389.67 | 5 | 28 |
2 | 7 | 2006.08 | 40 | 14.62 | 3493 | 2043 | 2.27 / 391.71 | 28 | 71 |
3 | 13 | 1920.68 | 20 | 14.60 | 3369 | 984 | 3.25 / 392.69 | 5 | 78 |
4 | 13 | 1403.40 | 20 | 14.62 | 2570 | 751 | 4.00 / 393.45 | 5 | 88 |
5 | 13 | 956.12 | 20 | 14.66 | 1892 | 555 | 4.56 / 394.00 | 5 | 94 |
6 | 13 | 48.16 | 20 | 14.95 | 415 | 124 | 4.68 / 394.12 | 5 | 90 |
7 | 13 | 14.20 | 20 | 14.95 | 349 | 104 | 4.79 / 394.23 | 5 | 86 |
8 | 8 | 0.12 | 179 | 14.91 | 315 | 841 | 5.63 / 395.07 | 5 | 140 |
9 | 14 | 0.04 | 21 | 14.88 | 310 | 97 | 5.72 / 395.17 | 38 | -99 |
Average= | 5.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.80 | 33 | 14.92 | 486 | 239 | 0.24 / 383.72 | 5 | 25 |
2 | 7 | 2008.60 | 40 | 14.62 | 3479 | 2035 | 2.27 / 385.76 | 25 | 72 |
3 | 13 | 1826.64 | 20 | 14.60 | 3241 | 946 | 3.22 / 386.70 | 5 | 79 |
4 | 13 | 1735.36 | 20 | 14.56 | 3097 | 902 | 4.12 / 387.60 | 5 | 82 |
5 | 13 | 813.84 | 20 | 14.72 | 1670 | 492 | 4.61 / 388.10 | 5 | 98 |
6 | 13 | 372.52 | 20 | 14.83 | 964 | 286 | 4.90 / 388.38 | 5 | 99 |
7 | 13 | 22.20 | 20 | 14.94 | 372 | 111 | 5.01 / 388.49 | 5 | 94 |
8 | 8 | 0.20 | 176 | 14.91 | 319 | 837 | 5.85 / 389.33 | 5 | 131 |
9 | 14 | -0.04 | 24 | 14.87 | 311 | 111 | 5.96 / 389.44 | 31 | -99 |
Average= | 5.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.84 | 33 | 14.92 | 484 | 238 | 0.24 / 378.04 | 5 | 29 |
2 | 7 | 2013.60 | 40 | 14.63 | 3485 | 2039 | 2.28 / 380.08 | 29 | 73 |
3 | 13 | 1922.80 | 20 | 14.61 | 3379 | 987 | 3.27 / 381.06 | 5 | 77 |
4 | 13 | 1299.44 | 20 | 14.64 | 2427 | 711 | 3.98 / 381.77 | 5 | 87 |
5 | 13 | 666.72 | 20 | 14.76 | 1441 | 425 | 4.40 / 382.20 | 5 | 99 |
6 | 13 | 220.68 | 20 | 14.89 | 717 | 214 | 4.61 / 382.41 | 5 | 96 |
7 | 13 | 20.92 | 20 | 14.95 | 371 | 111 | 4.73 / 382.52 | 5 | 91 |
8 | 8 | 0.12 | 176 | 14.91 | 323 | 848 | 5.57 / 383.37 | 5 | 129 |
9 | 14 | -0.04 | 24 | 14.88 | 310 | 111 | 5.68 / 383.48 | 40 | -99 |
Average= | 5.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.48 | 33 | 14.94 | 484 | 239 | 0.24 / 372.09 | 5 | 29 |
2 | 7 | 2012.80 | 40 | 14.63 | 3490 | 2042 | 2.28 / 374.14 | 29 | 73 |
3 | 13 | 1924.48 | 20 | 14.62 | 3380 | 988 | 3.27 / 375.12 | 5 | 76 |
4 | 13 | 1593.00 | 20 | 14.60 | 2865 | 837 | 4.11 / 375.96 | 5 | 85 |
5 | 13 | 905.12 | 20 | 14.70 | 1830 | 538 | 4.64 / 376.50 | 5 | 96 |
6 | 13 | 223.36 | 20 | 14.89 | 732 | 218 | 4.86 / 376.72 | 5 | 97 |
7 | 13 | 24.40 | 20 | 14.95 | 382 | 114 | 4.98 / 376.83 | 5 | 91 |
8 | 8 | 0.08 | 178 | 14.92 | 326 | 866 | 5.84 / 377.70 | 5 | 133 |
9 | 14 | -0.04 | 22 | 14.88 | 313 | 102 | 5.94 / 377.80 | 44 | -99 |
Average= | 5.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.08 | 33 | 14.93 | 468 | 231 | 0.23 / 366.50 | 5 | 30 |
2 | 7 | 2011.20 | 40 | 14.63 | 3488 | 2041 | 2.27 / 368.54 | 30 | 72 |
3 | 13 | 1915.36 | 20 | 14.61 | 3377 | 987 | 3.26 / 369.53 | 5 | 79 |
4 | 13 | 1285.40 | 20 | 14.66 | 2389 | 700 | 3.96 / 370.23 | 5 | 89 |
5 | 13 | 858.76 | 20 | 14.71 | 1747 | 514 | 4.47 / 370.74 | 5 | 97 |
6 | 13 | 94.80 | 20 | 14.94 | 514 | 154 | 4.63 / 370.90 | 5 | 92 |
7 | 8 | 0.20 | 197 | 14.93 | 321 | 944 | 5.57 / 371.84 | 5 | 136 |
8 | 14 | 0.00 | 3 | 14.91 | 323 | 14 | 5.59 / 371.85 | 36 | 110 |
Average= | 5.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.24 | 33 | 14.95 | 484 | 239 | 0.24 / 360.73 | 5 | 34 |
2 | 7 | 2005.16 | 40 | 14.64 | 3472 | 2033 | 2.27 / 362.76 | 34 | 73 |
3 | 13 | 1916.52 | 20 | 14.63 | 3347 | 979 | 3.25 / 363.74 | 5 | 77 |
4 | 13 | 1489.88 | 20 | 14.62 | 2691 | 787 | 4.04 / 364.53 | 5 | 84 |
5 | 13 | 932.16 | 20 | 14.70 | 1857 | 546 | 4.58 / 365.08 | 5 | 99 |
6 | 13 | 74.20 | 20 | 14.96 | 461 | 138 | 4.72 / 365.21 | 5 | 91 |
7 | 13 | 18.52 | 20 | 14.98 | 361 | 108 | 4.83 / 365.32 | 5 | 88 |
8 | 8 | 0.00 | 176 | 14.94 | 319 | 839 | 5.67 / 366.16 | 5 | 130 |
9 | 14 | -0.04 | 24 | 14.90 | 302 | 108 | 5.78 / 366.27 | 35 | -99 |
Average= | 5.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.96 | 33 | 14.95 | 494 | 244 | 0.24 / 355.11 | 5 | 33 |
2 | 7 | 2003.80 | 41 | 14.64 | 3470 | 2083 | 2.33 / 357.19 | 33 | 72 |
3 | 13 | 1911.72 | 20 | 14.62 | 3364 | 984 | 3.31 / 358.18 | 5 | 78 |
4 | 13 | 1376.24 | 20 | 14.65 | 2519 | 738 | 4.05 / 358.92 | 5 | 87 |
5 | 13 | 818.56 | 20 | 14.73 | 1685 | 496 | 4.54 / 359.41 | 5 | 98 |
6 | 13 | 73.72 | 20 | 14.97 | 469 | 140 | 4.69 / 359.55 | 5 | 92 |
7 | 8 | 0.12 | 193 | 14.95 | 314 | 906 | 5.59 / 360.46 | 5 | 131 |
8 | 14 | -0.04 | 7 | 14.92 | 313 | 33 | 5.62 / 360.49 | 32 | 135 |
Average= | 5.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.20 | 34 | 14.95 | 486 | 247 | 0.25 / 349.53 | 5 | 36 |
2 | 7 | 2005.20 | 40 | 14.64 | 3467 | 2030 | 2.28 / 351.56 | 36 | 73 |
3 | 13 | 1916.08 | 20 | 14.63 | 3357 | 982 | 3.26 / 352.54 | 5 | 77 |
4 | 13 | 1371.60 | 20 | 14.66 | 2516 | 738 | 4.00 / 353.28 | 5 | 86 |
5 | 13 | 823.76 | 20 | 14.74 | 1697 | 500 | 4.50 / 353.78 | 5 | 98 |
6 | 13 | 46.76 | 20 | 14.98 | 424 | 127 | 4.62 / 353.91 | 5 | 90 |
7 | 8 | 0.12 | 197 | 14.95 | 321 | 945 | 5.57 / 354.85 | 5 | 137 |
8 | 14 | -0.04 | 3 | 14.93 | 322 | 14 | 5.58 / 354.87 | 40 | 110 |
Average= | 5.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.68 | 33 | 14.95 | 502 | 248 | 0.25 / 343.63 | 5 | 34 |
2 | 3 | 1023.72 | 1 | 15.03 | 2079 | 31 | 0.28 / 343.67 | 5 | 39 |
3 | 7 | 2003.84 | 40 | 14.64 | 3473 | 2034 | 2.31 / 345.70 | 39 | 73 |
4 | 13 | 1917.00 | 20 | 14.63 | 3379 | 989 | 3.30 / 346.69 | 5 | 76 |
5 | 13 | 1388.76 | 20 | 14.65 | 2545 | 746 | 4.05 / 347.43 | 5 | 85 |
6 | 13 | 1052.52 | 20 | 14.68 | 2040 | 599 | 4.65 / 348.03 | 5 | 94 |
7 | 13 | 139.20 | 20 | 14.95 | 583 | 174 | 4.82 / 348.21 | 5 | 96 |
8 | 13 | 23.52 | 20 | 14.98 | 376 | 113 | 4.93 / 348.32 | 5 | 94 |
9 | 8 | 0.04 | 152 | 14.95 | 324 | 736 | 5.67 / 349.06 | 5 | 136 |
10 | 14 | -0.04 | 48 | 14.92 | 318 | 228 | 5.90 / 349.28 | 10 | -99 |
Average= | 5.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.84 | 33 | 14.96 | 488 | 241 | 0.24 / 337.65 | 5 | 33 |
2 | 7 | 2007.60 | 40 | 14.65 | 3472 | 2035 | 2.28 / 339.68 | 33 | 74 |
3 | 13 | 1912.24 | 20 | 14.63 | 3342 | 978 | 3.25 / 340.66 | 5 | 76 |
4 | 13 | 1583.36 | 20 | 14.62 | 2836 | 829 | 4.08 / 341.49 | 5 | 83 |
5 | 13 | 1105.60 | 20 | 14.68 | 2122 | 623 | 4.71 / 342.11 | 5 | 94 |
6 | 13 | 181.56 | 20 | 14.94 | 654 | 195 | 4.90 / 342.31 | 5 | 100 |
7 | 13 | 31.40 | 20 | 14.99 | 387 | 116 | 5.02 / 342.43 | 5 | 97 |
8 | 8 | 0.08 | 174 | 14.96 | 322 | 838 | 5.86 / 343.26 | 5 | 140 |
9 | 14 | 0.04 | 26 | 14.92 | 316 | 123 | 5.98 / 343.39 | 34 | -99 |
Average= | 5.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.24 | 33 | 14.98 | 468 | 231 | 0.23 / 331.92 | 5 | 31 |
2 | 7 | 2007.32 | 41 | 14.65 | 3486 | 2094 | 2.33 / 334.01 | 16 | 73 |
3 | 13 | 1916.76 | 20 | 14.63 | 3387 | 991 | 3.32 / 335.00 | 5 | 78 |
4 | 13 | 1281.48 | 20 | 14.67 | 2396 | 703 | 4.02 / 335.70 | 5 | 88 |
5 | 13 | 948.12 | 20 | 14.71 | 1896 | 558 | 4.58 / 336.26 | 5 | 97 |
6 | 13 | 141.64 | 20 | 14.96 | 588 | 176 | 4.75 / 336.44 | 5 | 97 |
7 | 8 | 0.12 | 189 | 14.96 | 325 | 919 | 5.67 / 337.36 | 5 | 138 |
8 | 14 | -0.04 | 11 | 14.93 | 319 | 52 | 5.72 / 337.41 | 30 | 137 |
Average= | 5.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.92 | 33 | 14.98 | 468 | 231 | 0.23 / 326.11 | 5 | 34 |
2 | 7 | 2004.04 | 40 | 14.65 | 3473 | 2035 | 2.27 / 328.15 | 34 | 72 |
3 | 13 | 1906.88 | 20 | 14.64 | 3323 | 973 | 3.24 / 329.12 | 5 | 78 |
4 | 13 | 1576.84 | 20 | 14.63 | 2835 | 830 | 4.07 / 329.95 | 5 | 84 |
5 | 13 | 896.32 | 20 | 14.75 | 1789 | 528 | 4.60 / 330.48 | 5 | 98 |
6 | 13 | 110.92 | 20 | 14.99 | 526 | 158 | 4.75 / 330.64 | 5 | 94 |
7 | 13 | 24.72 | 20 | 15.01 | 369 | 111 | 4.87 / 330.75 | 5 | 94 |
8 | 8 | 0.08 | 173 | 14.98 | 315 | 816 | 5.68 / 331.56 | 5 | 132 |
9 | 14 | -0.04 | 27 | 14.94 | 303 | 122 | 5.80 / 331.68 | 36 | -99 |
Average= | 5.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.28 | 33 | 14.99 | 490 | 242 | 0.24 / 320.63 | 5 | 33 |
2 | 7 | 2009.80 | 40 | 14.65 | 3488 | 2044 | 2.29 / 322.68 | 33 | 73 |
3 | 13 | 1917.24 | 20 | 14.64 | 3343 | 979 | 3.27 / 323.65 | 5 | 79 |
4 | 13 | 1201.28 | 20 | 14.70 | 2261 | 665 | 3.93 / 324.32 | 5 | 92 |
5 | 13 | 781.88 | 20 | 14.77 | 1620 | 479 | 4.41 / 324.80 | 5 | 100 |
6 | 13 | 56.92 | 20 | 15.01 | 429 | 129 | 4.54 / 324.93 | 5 | 93 |
7 | 8 | 0.08 | 188 | 14.98 | 319 | 898 | 5.44 / 325.82 | 5 | 131 |
8 | 14 | -0.04 | 12 | 14.95 | 316 | 57 | 5.49 / 325.88 | 29 | 139 |
Average= | 5.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.00 | 33 | 15.00 | 492 | 244 | 0.24 / 315.06 | 5 | 30 |
2 | 7 | 2003.04 | 40 | 14.66 | 3486 | 2044 | 2.29 / 317.10 | 30 | 75 |
3 | 13 | 1908.96 | 20 | 14.63 | 3367 | 985 | 3.27 / 318.09 | 5 | 78 |
4 | 13 | 1276.48 | 20 | 14.69 | 2371 | 697 | 3.97 / 318.78 | 5 | 90 |
5 | 13 | 771.48 | 20 | 14.78 | 1615 | 477 | 4.45 / 319.26 | 5 | 100 |
6 | 13 | 107.76 | 20 | 14.99 | 534 | 160 | 4.61 / 319.42 | 5 | 94 |
7 | 8 | 0.20 | 193 | 14.99 | 323 | 934 | 5.54 / 320.36 | 5 | 137 |
8 | 14 | 0.04 | 7 | 14.96 | 319 | 33 | 5.57 / 320.39 | 41 | 139 |
Average= | 5.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.60 | 33 | 14.99 | 490 | 242 | 0.24 / 309.43 | 5 | 29 |
2 | 7 | 2012.08 | 40 | 14.66 | 3495 | 2049 | 2.29 / 311.48 | 29 | 73 |
3 | 13 | 1924.56 | 20 | 14.63 | 3420 | 1001 | 3.29 / 312.48 | 5 | 77 |
4 | 13 | 1290.76 | 20 | 14.69 | 2418 | 710 | 4.00 / 313.19 | 5 | 89 |
5 | 13 | 850.28 | 20 | 14.76 | 1746 | 515 | 4.52 / 313.70 | 5 | 97 |
6 | 13 | 41.08 | 20 | 15.03 | 422 | 127 | 4.65 / 313.83 | 5 | 91 |
7 | 8 | 0.16 | 193 | 14.99 | 328 | 949 | 5.59 / 314.78 | 5 | 131 |
8 | 14 | 0.00 | 7 | 14.96 | 326 | 34 | 5.63 / 314.81 | 40 | 138 |
Average= | 5.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.60 | 33 | 15.01 | 481 | 238 | 0.24 / 303.59 | 5 | 26 |
2 | 7 | 2008.40 | 41 | 14.65 | 3485 | 2093 | 2.33 / 305.68 | 26 | 73 |
3 | 13 | 1713.08 | 20 | 14.67 | 3100 | 910 | 3.24 / 306.59 | 5 | 83 |
4 | 13 | 1513.36 | 20 | 14.64 | 2774 | 812 | 4.05 / 307.40 | 5 | 86 |
5 | 13 | 937.68 | 20 | 14.74 | 1880 | 554 | 4.61 / 307.96 | 5 | 98 |
6 | 13 | 69.80 | 20 | 15.02 | 465 | 140 | 4.75 / 308.10 | 5 | 92 |
7 | 13 | 17.72 | 20 | 15.03 | 369 | 111 | 4.86 / 308.21 | 5 | 92 |
8 | 8 | 0.12 | 167 | 14.99 | 329 | 824 | 5.68 / 309.03 | 5 | 137 |
9 | 14 | 0.04 | 33 | 14.96 | 316 | 156 | 5.84 / 309.19 | 31 | -99 |
Average= | 5.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.00 | 33 | 15.01 | 483 | 239 | 0.24 / 297.89 | 5 | 24 |
2 | 7 | 2003.68 | 40 | 14.66 | 3480 | 2041 | 2.28 / 299.93 | 24 | 75 |
3 | 13 | 1810.08 | 20 | 14.67 | 3187 | 935 | 3.21 / 300.86 | 5 | 80 |
4 | 13 | 1294.40 | 20 | 14.70 | 2415 | 710 | 3.92 / 301.57 | 5 | 88 |
5 | 13 | 958.24 | 20 | 14.74 | 1909 | 563 | 4.49 / 302.14 | 5 | 97 |
6 | 13 | 82.24 | 20 | 15.02 | 487 | 146 | 4.63 / 302.28 | 5 | 90 |
7 | 13 | 18.28 | 20 | 15.04 | 367 | 110 | 4.74 / 302.39 | 5 | 91 |
8 | 8 | 0.16 | 178 | 15.00 | 320 | 854 | 5.60 / 303.25 | 5 | 139 |
9 | 14 | 0.00 | 22 | 14.97 | 302 | 99 | 5.70 / 303.35 | 51 | -99 |
Average= | 5.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.32 | 33 | 15.02 | 491 | 243 | 0.24 / 292.23 | 5 | 27 |
2 | 7 | 2005.56 | 40 | 14.67 | 3495 | 2051 | 2.29 / 294.28 | 27 | 74 |
3 | 13 | 1810.04 | 20 | 14.67 | 3206 | 941 | 3.23 / 295.23 | 5 | 80 |
4 | 13 | 1301.28 | 20 | 14.70 | 2413 | 709 | 3.94 / 295.93 | 5 | 90 |
5 | 13 | 862.52 | 20 | 14.77 | 1756 | 519 | 4.46 / 296.45 | 5 | 98 |
6 | 13 | 52.28 | 20 | 15.04 | 433 | 130 | 4.59 / 296.58 | 5 | 90 |
7 | 13 | 30.16 | 20 | 15.04 | 388 | 117 | 4.71 / 296.70 | 5 | 93 |
8 | 8 | 0.00 | 176 | 15.01 | 318 | 840 | 5.55 / 297.54 | 5 | 141 |
9 | 14 | -0.04 | 24 | 14.97 | 304 | 109 | 5.66 / 297.65 | 38 | -99 |
Average= | 5.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.88 | 33 | 15.03 | 454 | 225 | 0.23 / 286.58 | 5 | 23 |
2 | 7 | 2007.64 | 40 | 14.66 | 3490 | 2047 | 2.27 / 288.62 | 23 | 73 |
3 | 13 | 1920.16 | 20 | 14.65 | 3354 | 983 | 3.25 / 289.61 | 5 | 77 |
4 | 13 | 1370.64 | 20 | 14.69 | 2521 | 741 | 4.00 / 290.35 | 5 | 89 |
5 | 13 | 934.64 | 20 | 14.76 | 1878 | 554 | 4.55 / 290.90 | 5 | 96 |
6 | 13 | 36.72 | 20 | 15.05 | 405 | 122 | 4.67 / 291.02 | 5 | 91 |
7 | 8 | 0.20 | 193 | 15.02 | 322 | 933 | 5.60 / 291.96 | 5 | 131 |
8 | 14 | 0.00 | 7 | 14.99 | 319 | 33 | 5.64 / 291.99 | 37 | 136 |
Average= | 5.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.08 | 33 | 15.02 | 481 | 238 | 0.24 / 280.92 | 5 | 26 |
2 | 7 | 2008.80 | 40 | 14.66 | 3501 | 2053 | 2.29 / 282.97 | 26 | 74 |
3 | 13 | 1810.48 | 20 | 14.66 | 3233 | 948 | 3.24 / 283.92 | 5 | 79 |
4 | 13 | 1400.72 | 20 | 14.68 | 2591 | 761 | 4.00 / 284.68 | 5 | 87 |
5 | 13 | 761.20 | 20 | 14.81 | 1595 | 472 | 4.47 / 285.15 | 5 | 99 |
6 | 13 | 52.20 | 20 | 15.05 | 431 | 130 | 4.60 / 285.28 | 5 | 90 |
7 | 13 | 16.48 | 20 | 15.06 | 364 | 110 | 4.71 / 285.39 | 5 | 91 |
8 | 8 | 0.20 | 176 | 15.02 | 322 | 851 | 5.56 / 286.24 | 5 | 133 |
9 | 14 | 0.00 | 24 | 14.98 | 308 | 111 | 5.67 / 286.35 | 36 | -99 |
Average= | 5.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.36 | 33 | 15.04 | 474 | 235 | 0.24 / 275.18 | 5 | 25 |
2 | 7 | 2005.04 | 40 | 14.67 | 3501 | 2054 | 2.29 / 277.23 | 25 | 75 |
3 | 13 | 1907.72 | 20 | 14.65 | 3372 | 988 | 3.28 / 278.22 | 5 | 79 |
4 | 13 | 1370.64 | 20 | 14.69 | 2529 | 743 | 4.02 / 278.96 | 5 | 89 |
5 | 13 | 835.68 | 20 | 14.80 | 1720 | 509 | 4.53 / 279.47 | 5 | 98 |
6 | 13 | 66.40 | 20 | 15.05 | 452 | 136 | 4.67 / 279.61 | 5 | 92 |
7 | 13 | 18.52 | 20 | 15.06 | 368 | 111 | 4.78 / 279.72 | 5 | 92 |
8 | 8 | 0.16 | 173 | 15.02 | 322 | 837 | 5.61 / 280.56 | 5 | 130 |
9 | 14 | 0.04 | 27 | 14.99 | 304 | 123 | 5.74 / 280.68 | 49 | -99 |
Average= | 5.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.16 | 33 | 15.04 | 464 | 230 | 0.23 / 269.50 | 5 | 24 |
2 | 7 | 2006.36 | 40 | 14.67 | 3503 | 2056 | 2.29 / 271.56 | 24 | 74 |
3 | 13 | 1914.40 | 20 | 14.65 | 3382 | 991 | 3.28 / 272.55 | 5 | 78 |
4 | 13 | 1284.00 | 20 | 14.72 | 2384 | 702 | 3.98 / 273.25 | 5 | 88 |
5 | 13 | 849.92 | 20 | 14.80 | 1717 | 508 | 4.49 / 273.76 | 5 | 98 |
6 | 13 | 45.28 | 20 | 15.07 | 405 | 122 | 4.61 / 273.88 | 5 | 90 |
7 | 13 | 13.68 | 20 | 15.07 | 339 | 102 | 4.71 / 273.98 | 5 | 91 |
8 | 8 | 0.16 | 171 | 15.03 | 322 | 828 | 5.54 / 274.81 | 5 | 137 |
9 | 14 | 0.08 | 29 | 15.00 | 308 | 134 | 5.67 / 274.94 | 37 | -99 |
Average= | 5.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.48 | 33 | 15.04 | 449 | 223 | 0.22 / 263.90 | 5 | 23 |
2 | 7 | 2017.20 | 40 | 14.67 | 3514 | 2062 | 2.28 / 265.96 | 23 | 74 |
3 | 13 | 1930.08 | 20 | 14.65 | 3394 | 994 | 3.28 / 266.96 | 5 | 79 |
4 | 13 | 1285.48 | 20 | 14.73 | 2384 | 702 | 3.98 / 267.66 | 5 | 89 |
5 | 13 | 751.24 | 20 | 14.84 | 1558 | 462 | 4.44 / 268.12 | 5 | 99 |
6 | 13 | 49.88 | 20 | 15.07 | 407 | 123 | 4.57 / 268.25 | 5 | 90 |
7 | 13 | 28.28 | 20 | 15.07 | 368 | 111 | 4.68 / 268.36 | 5 | 93 |
8 | 8 | 0.16 | 174 | 15.04 | 305 | 798 | 5.48 / 269.16 | 5 | 135 |
9 | 14 | 0.00 | 26 | 15.01 | 291 | 114 | 5.59 / 269.27 | 30 | -99 |
Average= | 5.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.24 | 33 | 15.06 | 467 | 232 | 0.23 / 258.07 | 5 | 23 |
2 | 7 | 2004.24 | 40 | 14.67 | 3483 | 2044 | 2.28 / 260.11 | 23 | 74 |
3 | 13 | 1909.44 | 20 | 14.66 | 3354 | 983 | 3.26 / 261.09 | 5 | 79 |
4 | 13 | 1376.68 | 20 | 14.70 | 2539 | 746 | 4.01 / 261.84 | 5 | 89 |
5 | 13 | 927.16 | 20 | 14.79 | 1836 | 543 | 4.55 / 262.38 | 5 | 99 |
6 | 13 | 339.52 | 20 | 14.96 | 903 | 270 | 4.82 / 262.65 | 5 | 101 |
7 | 13 | 20.40 | 20 | 15.06 | 358 | 108 | 4.93 / 262.76 | 5 | 96 |
8 | 8 | 0.16 | 176 | 15.03 | 308 | 815 | 5.74 / 263.58 | 5 | 134 |
9 | 14 | 0.00 | 24 | 15.00 | 291 | 105 | 5.85 / 263.68 | 40 | -99 |
Average= | 5.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.60 | 33 | 15.05 | 452 | 224 | 0.22 / 252.31 | 5 | 24 |
2 | 7 | 2013.88 | 40 | 14.68 | 3507 | 2059 | 2.28 / 254.37 | 24 | 75 |
3 | 13 | 1919.60 | 20 | 14.66 | 3373 | 989 | 3.27 / 255.36 | 5 | 79 |
4 | 13 | 1583.20 | 20 | 14.66 | 2854 | 837 | 4.11 / 256.20 | 5 | 85 |
5 | 13 | 806.40 | 20 | 14.83 | 1652 | 490 | 4.60 / 256.69 | 5 | 99 |
6 | 13 | 67.08 | 20 | 15.07 | 447 | 135 | 4.73 / 256.82 | 5 | 94 |
7 | 13 | 20.36 | 20 | 15.08 | 354 | 107 | 4.84 / 256.93 | 5 | 93 |
8 | 8 | 0.12 | 176 | 15.05 | 303 | 803 | 5.64 / 257.73 | 5 | 129 |
9 | 14 | 0.00 | 24 | 15.02 | 282 | 102 | 5.75 / 257.83 | 36 | -99 |
Average= | 5.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.00 | 33 | 15.06 | 453 | 225 | 0.23 / 246.77 | 5 | 24 |
2 | 7 | 2012.20 | 40 | 14.68 | 3494 | 2052 | 2.28 / 248.82 | 24 | 73 |
3 | 13 | 1820.96 | 20 | 14.68 | 3223 | 946 | 3.22 / 249.77 | 5 | 80 |
4 | 13 | 1295.12 | 20 | 14.73 | 2402 | 708 | 3.93 / 250.48 | 5 | 90 |
5 | 13 | 757.68 | 20 | 14.84 | 1581 | 469 | 4.40 / 250.95 | 5 | 101 |
6 | 13 | 55.96 | 20 | 15.08 | 425 | 128 | 4.53 / 251.08 | 5 | 93 |
7 | 13 | 31.80 | 20 | 15.08 | 371 | 112 | 4.64 / 251.19 | 5 | 93 |
8 | 8 | 0.08 | 171 | 15.05 | 302 | 777 | 5.42 / 251.97 | 5 | 130 |
9 | 14 | 0.00 | 29 | 15.02 | 282 | 123 | 5.54 / 252.09 | 40 | -99 |
Average= | 5.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.72 | 32 | 15.07 | 449 | 217 | 0.22 / 240.97 | 5 | 23 |
2 | 7 | 2006.72 | 40 | 14.69 | 3487 | 2049 | 2.27 / 243.02 | 23 | 74 |
3 | 13 | 1921.44 | 20 | 14.67 | 3401 | 998 | 3.26 / 244.02 | 5 | 77 |
4 | 13 | 1599.24 | 20 | 14.67 | 2881 | 845 | 4.11 / 244.86 | 5 | 84 |
5 | 13 | 925.16 | 20 | 14.80 | 1844 | 546 | 4.65 / 245.41 | 5 | 98 |
6 | 13 | 66.28 | 20 | 15.08 | 439 | 132 | 4.79 / 245.54 | 5 | 93 |
7 | 13 | 37.36 | 20 | 15.09 | 379 | 114 | 4.90 / 245.65 | 5 | 92 |
8 | 8 | 0.16 | 176 | 15.06 | 299 | 793 | 5.69 / 246.45 | 5 | 132 |
9 | 14 | 0.04 | 24 | 15.03 | 283 | 102 | 5.80 / 246.55 | 44 | -99 |
Average= | 5.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.32 | 32 | 15.07 | 458 | 221 | 0.22 / 235.29 | 5 | 24 |
2 | 7 | 2004.76 | 40 | 14.69 | 3488 | 2050 | 2.27 / 237.34 | 24 | 74 |
3 | 13 | 1910.16 | 20 | 14.67 | 3365 | 987 | 3.26 / 238.33 | 5 | 79 |
4 | 13 | 1488.88 | 20 | 14.69 | 2703 | 794 | 4.05 / 239.12 | 5 | 87 |
5 | 13 | 813.12 | 20 | 14.84 | 1666 | 494 | 4.55 / 239.61 | 5 | 99 |
6 | 13 | 70.04 | 20 | 15.08 | 447 | 135 | 4.68 / 239.75 | 5 | 94 |
7 | 13 | 20.16 | 20 | 15.09 | 347 | 105 | 4.79 / 239.85 | 5 | 92 |
8 | 8 | 0.08 | 176 | 15.06 | 301 | 798 | 5.58 / 240.65 | 5 | 142 |
9 | 14 | -0.08 | 24 | 15.03 | 278 | 100 | 5.68 / 240.75 | 37 | -99 |
Average= | 5.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.76 | 32 | 15.07 | 443 | 214 | 0.21 / 229.67 | 5 | 24 |
2 | 7 | 2011.88 | 40 | 14.69 | 3497 | 2055 | 2.27 / 231.72 | 24 | 75 |
3 | 13 | 1916.52 | 20 | 14.67 | 3354 | 984 | 3.25 / 232.71 | 5 | 78 |
4 | 13 | 1386.16 | 20 | 14.72 | 2530 | 745 | 4.00 / 233.45 | 5 | 89 |
5 | 13 | 736.32 | 20 | 14.87 | 1545 | 459 | 4.46 / 233.91 | 5 | 100 |
6 | 13 | 88.92 | 20 | 15.08 | 484 | 146 | 4.60 / 234.06 | 5 | 92 |
7 | 13 | 21.88 | 20 | 15.09 | 356 | 107 | 4.71 / 234.16 | 5 | 92 |
8 | 8 | 0.16 | 173 | 15.06 | 303 | 789 | 5.50 / 234.95 | 5 | 136 |
9 | 14 | 0.00 | 27 | 15.03 | 285 | 116 | 5.62 / 235.07 | 35 | -99 |
Average= | 5.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.24 | 32 | 15.08 | 440 | 212 | 0.21 / 224.04 | 5 | 25 |
2 | 7 | 2013.64 | 40 | 14.68 | 3511 | 2062 | 2.27 / 226.10 | 25 | 75 |
3 | 13 | 1917.00 | 20 | 14.67 | 3382 | 992 | 3.27 / 227.09 | 5 | 79 |
4 | 13 | 1345.64 | 20 | 14.73 | 2480 | 731 | 4.00 / 227.82 | 5 | 90 |
5 | 13 | 796.72 | 20 | 14.85 | 1632 | 485 | 4.48 / 228.31 | 5 | 100 |
6 | 13 | 52.96 | 20 | 15.09 | 418 | 126 | 4.61 / 228.43 | 5 | 92 |
7 | 13 | 31.88 | 20 | 15.09 | 373 | 113 | 4.72 / 228.55 | 5 | 92 |
8 | 8 | 0.12 | 169 | 15.07 | 303 | 772 | 5.49 / 229.32 | 5 | 137 |
9 | 14 | 0.00 | 31 | 15.04 | 289 | 135 | 5.63 / 229.45 | 33 | -99 |
Average= | 5.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.76 | 32 | 15.08 | 452 | 218 | 0.22 / 218.35 | 5 | 27 |
2 | 7 | 2010.76 | 40 | 14.70 | 3488 | 2051 | 2.27 / 220.41 | 27 | 74 |
3 | 13 | 1817.24 | 20 | 14.69 | 3206 | 942 | 3.21 / 221.35 | 5 | 81 |
4 | 13 | 1619.64 | 20 | 14.67 | 2893 | 849 | 4.06 / 222.20 | 5 | 86 |
5 | 13 | 815.44 | 20 | 14.85 | 1659 | 493 | 4.55 / 222.69 | 5 | 99 |
6 | 13 | 77.08 | 20 | 15.09 | 450 | 136 | 4.69 / 222.82 | 5 | 92 |
7 | 13 | 18.76 | 20 | 15.11 | 341 | 103 | 4.79 / 222.93 | 5 | 92 |
8 | 8 | 0.04 | 173 | 15.07 | 301 | 785 | 5.58 / 223.71 | 5 | 134 |
9 | 14 | 0.00 | 27 | 15.04 | 280 | 114 | 5.69 / 223.83 | 41 | -99 |
Average= | 5.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.16 | 32 | 15.08 | 464 | 224 | 0.22 / 212.93 | 5 | 25 |
2 | 7 | 2010.88 | 40 | 14.69 | 3502 | 2058 | 2.28 / 214.99 | 25 | 73 |
3 | 13 | 1916.08 | 20 | 14.68 | 3361 | 987 | 3.27 / 215.98 | 5 | 78 |
4 | 13 | 1294.68 | 20 | 14.76 | 2382 | 703 | 3.97 / 216.68 | 5 | 90 |
5 | 13 | 661.52 | 20 | 14.90 | 1417 | 422 | 4.39 / 217.10 | 5 | 101 |
6 | 13 | 58.40 | 20 | 15.10 | 422 | 127 | 4.52 / 217.23 | 5 | 92 |
7 | 8 | 0.12 | 193 | 15.08 | 301 | 876 | 5.40 / 218.10 | 5 | 133 |
8 | 14 | -0.04 | 7 | 15.05 | 300 | 32 | 5.43 / 218.14 | 43 | 150 |
Average= | 5.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.76 | 32 | 15.09 | 465 | 225 | 0.22 / 207.28 | 5 | 28 |
2 | 7 | 2005.88 | 41 | 14.69 | 3502 | 2109 | 2.33 / 209.39 | 8 | 74 |
3 | 13 | 1911.48 | 20 | 14.68 | 3358 | 986 | 3.32 / 210.38 | 5 | 78 |
4 | 13 | 1360.24 | 20 | 14.74 | 2494 | 735 | 4.05 / 211.11 | 5 | 88 |
5 | 13 | 943.88 | 20 | 14.81 | 1869 | 554 | 4.61 / 211.67 | 5 | 97 |
6 | 13 | 57.56 | 20 | 15.10 | 426 | 129 | 4.74 / 211.79 | 5 | 92 |
7 | 8 | 0.08 | 191 | 15.08 | 303 | 873 | 5.61 / 212.67 | 5 | 129 |
8 | 14 | 0.04 | 9 | 15.05 | 298 | 40 | 5.65 / 212.71 | 30 | 155 |
Average= | 5.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.16 | 32 | 15.09 | 449 | 217 | 0.22 / 201.77 | 5 | 28 |
2 | 7 | 2011.60 | 40 | 14.70 | 3491 | 2053 | 2.27 / 203.83 | 28 | 74 |
3 | 13 | 1917.88 | 20 | 14.69 | 3361 | 987 | 3.26 / 204.81 | 5 | 78 |
4 | 13 | 1501.36 | 20 | 14.71 | 2709 | 797 | 4.05 / 205.61 | 5 | 86 |
5 | 13 | 637.08 | 20 | 14.92 | 1364 | 407 | 4.46 / 206.02 | 5 | 101 |
6 | 13 | 89.36 | 20 | 15.10 | 473 | 143 | 4.60 / 206.16 | 5 | 94 |
7 | 8 | 0.08 | 195 | 15.09 | 297 | 874 | 5.48 / 207.03 | 5 | 141 |
8 | 14 | 0.00 | 5 | 15.06 | 298 | 22 | 5.50 / 207.06 | 46 | 146 |
Average= | 5.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.36 | 32 | 15.10 | 470 | 227 | 0.23 / 196.22 | 5 | 28 |
2 | 7 | 2012.28 | 40 | 14.71 | 3491 | 2054 | 2.28 / 198.28 | 28 | 73 |
3 | 13 | 1809.60 | 20 | 14.71 | 3206 | 943 | 3.22 / 199.22 | 5 | 80 |
4 | 13 | 1401.16 | 20 | 14.73 | 2552 | 752 | 3.98 / 199.97 | 5 | 88 |
5 | 13 | 952.24 | 20 | 14.82 | 1876 | 556 | 4.53 / 200.53 | 5 | 97 |
6 | 13 | 44.72 | 20 | 15.11 | 397 | 120 | 4.65 / 200.65 | 5 | 93 |
7 | 8 | 0.24 | 191 | 15.09 | 301 | 868 | 5.52 / 201.52 | 5 | 132 |
8 | 14 | 0.04 | 9 | 15.06 | 294 | 40 | 5.56 / 201.56 | 40 | 137 |
Average= | 5.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.64 | 32 | 15.10 | 450 | 217 | 0.22 / 190.63 | 5 | 28 |
2 | 7 | 2006.44 | 40 | 14.72 | 3480 | 2049 | 2.27 / 192.68 | 28 | 74 |
3 | 13 | 1925.92 | 20 | 14.70 | 3376 | 993 | 3.26 / 193.68 | 5 | 78 |
4 | 13 | 1382.72 | 20 | 14.75 | 2541 | 750 | 4.01 / 194.43 | 5 | 88 |
5 | 13 | 943.36 | 20 | 14.83 | 1842 | 546 | 4.55 / 194.97 | 5 | 97 |
6 | 13 | 47.00 | 20 | 15.12 | 399 | 121 | 4.68 / 195.09 | 5 | 90 |
7 | 8 | 0.24 | 193 | 15.09 | 300 | 874 | 5.55 / 195.97 | 5 | 133 |
8 | 14 | 0.00 | 7 | 15.07 | 298 | 31 | 5.58 / 196.00 | 38 | 142 |
Average= | 5.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.88 | 32 | 15.10 | 460 | 222 | 0.22 / 185.19 | 5 | 29 |
2 | 7 | 2011.48 | 40 | 14.71 | 3476 | 2045 | 2.27 / 187.24 | 29 | 73 |
3 | 13 | 1913.64 | 20 | 14.70 | 3333 | 980 | 3.25 / 188.21 | 5 | 78 |
4 | 13 | 1376.12 | 20 | 14.76 | 2513 | 742 | 3.99 / 188.96 | 5 | 88 |
5 | 13 | 713.20 | 20 | 14.91 | 1495 | 446 | 4.44 / 189.40 | 5 | 100 |
6 | 13 | 49.28 | 20 | 15.12 | 398 | 120 | 4.56 / 189.52 | 5 | 92 |
7 | 8 | 0.08 | 193 | 15.10 | 296 | 863 | 5.42 / 190.39 | 5 | 136 |
8 | 14 | -0.04 | 7 | 15.07 | 294 | 31 | 5.45 / 190.42 | 39 | 146 |
Average= | 5.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.92 | 33 | 15.10 | 449 | 224 | 0.22 / 179.57 | 5 | 28 |
2 | 7 | 2013.48 | 41 | 14.70 | 3502 | 2111 | 2.33 / 181.68 | 28 | 74 |
3 | 13 | 1920.84 | 20 | 14.69 | 3359 | 987 | 3.32 / 182.67 | 5 | 78 |
4 | 13 | 1493.36 | 20 | 14.72 | 2700 | 795 | 4.12 / 183.47 | 5 | 86 |
5 | 13 | 809.92 | 20 | 14.88 | 1644 | 489 | 4.61 / 183.96 | 5 | 99 |
6 | 13 | 38.60 | 20 | 15.13 | 381 | 115 | 4.72 / 184.07 | 5 | 92 |
7 | 8 | 0.12 | 188 | 15.10 | 297 | 843 | 5.56 / 184.91 | 5 | 134 |
8 | 14 | 0.04 | 12 | 15.08 | 295 | 53 | 5.62 / 184.97 | 29 | 141 |
Average= | 5.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.56 | 33 | 15.11 | 446 | 222 | 0.22 / 174.13 | 5 | 27 |
2 | 7 | 2004.56 | 40 | 14.71 | 3495 | 2056 | 2.28 / 176.19 | 27 | 74 |
3 | 13 | 1909.04 | 20 | 14.70 | 3361 | 988 | 3.27 / 177.18 | 5 | 78 |
4 | 13 | 1183.56 | 20 | 14.81 | 2233 | 661 | 3.93 / 177.84 | 5 | 93 |
5 | 13 | 778.88 | 20 | 14.89 | 1603 | 477 | 4.41 / 178.32 | 5 | 100 |
6 | 13 | 55.52 | 20 | 15.12 | 415 | 125 | 4.53 / 178.44 | 5 | 92 |
7 | 8 | 0.20 | 184 | 15.10 | 301 | 836 | 5.37 / 179.28 | 5 | 134 |
8 | 14 | 0.00 | 16 | 15.07 | 297 | 72 | 5.44 / 179.35 | 30 | 148 |
Average= | 5.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.24 | 32 | 15.10 | 473 | 229 | 0.23 / 168.72 | 5 | 29 |
2 | 7 | 2005.44 | 40 | 14.72 | 3494 | 2057 | 2.29 / 170.77 | 29 | 74 |
3 | 13 | 1911.56 | 20 | 14.71 | 3336 | 981 | 3.27 / 171.75 | 5 | 78 |
4 | 13 | 1372.32 | 20 | 14.76 | 2507 | 740 | 4.01 / 172.49 | 5 | 88 |
5 | 13 | 606.60 | 20 | 14.95 | 1330 | 398 | 4.41 / 172.89 | 5 | 102 |
6 | 13 | 51.92 | 20 | 15.13 | 405 | 123 | 4.53 / 173.01 | 5 | 91 |
7 | 8 | 0.20 | 184 | 15.11 | 297 | 826 | 5.35 / 173.84 | 5 | 131 |
8 | 14 | 0.00 | 16 | 15.08 | 295 | 71 | 5.42 / 173.91 | 32 | 150 |
Average= | 5.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.08 | 32 | 15.10 | 469 | 227 | 0.23 / 163.06 | 5 | 30 |
2 | 7 | 2006.88 | 41 | 14.72 | 3486 | 2104 | 2.33 / 165.16 | 30 | 74 |
3 | 13 | 1914.64 | 20 | 14.70 | 3362 | 988 | 3.32 / 166.15 | 5 | 78 |
4 | 13 | 1369.76 | 20 | 14.77 | 2496 | 737 | 4.06 / 166.89 | 5 | 88 |
5 | 13 | 922.44 | 20 | 14.86 | 1828 | 543 | 4.60 / 167.43 | 5 | 97 |
6 | 13 | 61.00 | 20 | 15.13 | 426 | 129 | 4.73 / 167.56 | 5 | 94 |
7 | 8 | 0.16 | 193 | 15.10 | 306 | 892 | 5.62 / 168.45 | 5 | 134 |
8 | 14 | -0.04 | 7 | 15.07 | 303 | 32 | 5.65 / 168.49 | 39 | 148 |
Average= | 5.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.32 | 32 | 15.10 | 471 | 228 | 0.23 / 157.49 | 5 | 32 |
2 | 7 | 2003.60 | 40 | 14.73 | 3477 | 2049 | 2.28 / 159.53 | 32 | 73 |
3 | 13 | 1906.00 | 20 | 14.71 | 3335 | 981 | 3.26 / 160.52 | 5 | 78 |
4 | 13 | 1350.96 | 20 | 14.79 | 2474 | 732 | 3.99 / 161.25 | 5 | 88 |
5 | 13 | 706.48 | 20 | 14.93 | 1488 | 444 | 4.43 / 161.69 | 5 | 100 |
6 | 13 | 76.96 | 20 | 15.13 | 451 | 136 | 4.57 / 161.83 | 5 | 94 |
7 | 13 | 15.96 | 20 | 15.14 | 337 | 102 | 4.67 / 161.93 | 5 | 94 |
8 | 8 | 0.16 | 173 | 15.11 | 302 | 789 | 5.46 / 162.72 | 5 | 133 |
9 | 14 | -0.04 | 27 | 15.07 | 283 | 115 | 5.58 / 162.83 | 39 | -99 |
Average= | 5.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.84 | 32 | 15.12 | 462 | 224 | 0.22 / 152.03 | 5 | 32 |
2 | 7 | 2009.12 | 40 | 14.73 | 3486 | 2054 | 2.28 / 154.08 | 32 | 73 |
3 | 13 | 1923.04 | 20 | 14.72 | 3359 | 989 | 3.27 / 155.07 | 5 | 78 |
4 | 13 | 1166.36 | 20 | 14.84 | 2198 | 652 | 3.92 / 155.72 | 5 | 91 |
5 | 13 | 718.96 | 20 | 14.93 | 1498 | 447 | 4.37 / 156.17 | 5 | 100 |
6 | 13 | 161.60 | 20 | 15.10 | 593 | 179 | 4.55 / 156.35 | 5 | 97 |
7 | 8 | 0.12 | 188 | 15.11 | 301 | 855 | 5.40 / 157.20 | 5 | 130 |
8 | 14 | -0.04 | 12 | 15.08 | 295 | 53 | 5.45 / 157.26 | 29 | 150 |
Average= | 5.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.56 | 32 | 15.12 | 473 | 229 | 0.23 / 146.41 | 5 | 31 |
2 | 7 | 2005.56 | 40 | 14.74 | 3473 | 2048 | 2.28 / 148.45 | 31 | 74 |
3 | 13 | 1912.96 | 20 | 14.72 | 3359 | 989 | 3.27 / 149.44 | 5 | 78 |
4 | 13 | 1372.76 | 20 | 14.79 | 2524 | 747 | 4.01 / 150.19 | 5 | 88 |
5 | 13 | 930.08 | 20 | 14.87 | 1845 | 549 | 4.56 / 150.74 | 5 | 99 |
6 | 13 | 104.96 | 20 | 15.12 | 503 | 152 | 4.71 / 150.89 | 5 | 95 |
7 | 8 | 0.16 | 189 | 15.12 | 302 | 863 | 5.58 / 151.75 | 5 | 130 |
8 | 14 | 0.04 | 11 | 15.09 | 303 | 50 | 5.63 / 151.80 | 32 | 142 |
Average= | 5.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.88 | 32 | 15.11 | 470 | 227 | 0.23 / 140.74 | 5 | 34 |
2 | 7 | 2006.00 | 40 | 14.74 | 3476 | 2049 | 2.28 / 142.79 | 34 | 72 |
3 | 13 | 1812.92 | 20 | 14.75 | 3199 | 944 | 3.22 / 143.73 | 5 | 78 |
4 | 13 | 1717.28 | 20 | 14.70 | 3057 | 899 | 4.12 / 144.63 | 5 | 82 |
5 | 13 | 791.92 | 20 | 14.91 | 1634 | 487 | 4.61 / 145.12 | 5 | 99 |
6 | 13 | 62.20 | 20 | 15.15 | 435 | 132 | 4.74 / 145.25 | 5 | 92 |
7 | 8 | 0.12 | 191 | 15.13 | 306 | 884 | 5.62 / 146.14 | 5 | 138 |
8 | 14 | -0.08 | 9 | 15.10 | 303 | 41 | 5.66 / 146.18 | 39 | 149 |
Average= | 5.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.76 | 32 | 15.13 | 450 | 218 | 0.22 / 135.08 | 5 | 28 |
2 | 7 | 2003.80 | 40 | 14.74 | 3481 | 2052 | 2.27 / 137.13 | 28 | 74 |
3 | 13 | 1906.20 | 20 | 14.73 | 3357 | 989 | 3.26 / 138.12 | 5 | 78 |
4 | 13 | 1282.72 | 20 | 14.81 | 2379 | 705 | 3.96 / 138.82 | 5 | 90 |
5 | 13 | 747.16 | 20 | 14.93 | 1556 | 465 | 4.43 / 139.29 | 5 | 100 |
6 | 13 | 175.92 | 20 | 15.10 | 629 | 190 | 4.62 / 139.48 | 5 | 97 |
7 | 13 | 30.40 | 20 | 15.14 | 372 | 113 | 4.73 / 139.59 | 5 | 94 |
8 | 8 | 0.08 | 169 | 15.12 | 308 | 787 | 5.52 / 140.38 | 5 | 133 |
9 | 14 | 0.04 | 31 | 15.08 | 292 | 137 | 5.65 / 140.51 | 31 | -99 |
Average= | 5.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.48 | 32 | 15.13 | 454 | 220 | 0.22 / 129.70 | 5 | 31 |
2 | 7 | 2004.28 | 40 | 14.75 | 3475 | 2050 | 2.27 / 131.75 | 31 | 74 |
3 | 13 | 1908.36 | 20 | 14.74 | 3346 | 986 | 3.26 / 132.74 | 5 | 79 |
4 | 13 | 1250.40 | 20 | 14.83 | 2329 | 691 | 3.95 / 133.43 | 5 | 91 |
5 | 13 | 625.64 | 20 | 14.98 | 1358 | 407 | 4.35 / 133.84 | 5 | 101 |
6 | 13 | 48.12 | 20 | 15.16 | 399 | 121 | 4.48 / 133.96 | 5 | 93 |
7 | 8 | 0.20 | 186 | 15.14 | 298 | 839 | 5.31 / 134.80 | 5 | 132 |
8 | 14 | -0.04 | 14 | 15.11 | 295 | 62 | 5.38 / 134.86 | 36 | 163 |
Average= | 5.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.36 | 32 | 15.14 | 473 | 229 | 0.23 / 124.00 | 5 | 29 |
2 | 7 | 2007.40 | 40 | 14.75 | 3482 | 2054 | 2.28 / 126.05 | 29 | 74 |
3 | 13 | 1917.56 | 20 | 14.73 | 3382 | 996 | 3.28 / 127.05 | 5 | 79 |
4 | 13 | 1503.28 | 20 | 14.77 | 2707 | 800 | 4.08 / 127.85 | 5 | 87 |
5 | 13 | 1026.44 | 20 | 14.86 | 2001 | 595 | 4.67 / 128.44 | 5 | 98 |
6 | 13 | 59.64 | 20 | 15.16 | 421 | 128 | 4.80 / 128.57 | 5 | 94 |
7 | 8 | 0.12 | 193 | 15.13 | 301 | 879 | 5.68 / 129.45 | 5 | 133 |
8 | 14 | 0.04 | 7 | 15.11 | 299 | 32 | 5.71 / 129.48 | 34 | 152 |
Average= | 5.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.84 | 32 | 15.14 | 446 | 216 | 0.22 / 118.47 | 5 | 28 |
2 | 7 | 2011.68 | 40 | 14.74 | 3489 | 2057 | 2.27 / 120.52 | 28 | 74 |
3 | 13 | 1926.56 | 20 | 14.73 | 3401 | 1002 | 3.28 / 121.53 | 5 | 79 |
4 | 13 | 1383.80 | 20 | 14.79 | 2549 | 754 | 4.03 / 122.28 | 5 | 89 |
5 | 13 | 718.72 | 20 | 14.95 | 1518 | 454 | 4.48 / 122.73 | 5 | 101 |
6 | 13 | 49.16 | 20 | 15.16 | 406 | 123 | 4.61 / 122.86 | 5 | 95 |
7 | 8 | 0.12 | 186 | 15.14 | 302 | 850 | 5.46 / 123.71 | 5 | 133 |
8 | 14 | 0.00 | 14 | 15.11 | 298 | 63 | 5.52 / 123.77 | 32 | 153 |
Average= | 5.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.00 | 32 | 15.14 | 458 | 222 | 0.22 / 113.05 | 5 | 29 |
2 | 7 | 2014.48 | 40 | 14.75 | 3498 | 2064 | 2.29 / 115.11 | 29 | 75 |
3 | 13 | 1920.88 | 20 | 14.74 | 3368 | 993 | 3.28 / 116.10 | 5 | 79 |
4 | 13 | 1192.40 | 20 | 14.85 | 2263 | 672 | 3.95 / 116.78 | 5 | 93 |
5 | 13 | 678.96 | 20 | 14.97 | 1455 | 436 | 4.39 / 117.21 | 5 | 101 |
6 | 13 | 63.16 | 20 | 15.16 | 435 | 132 | 4.52 / 117.34 | 5 | 96 |
7 | 8 | 0.12 | 186 | 15.14 | 300 | 845 | 5.36 / 118.19 | 5 | 129 |
8 | 14 | -0.08 | 14 | 15.11 | 300 | 63 | 5.43 / 118.25 | 36 | 174 |
Average= | 5.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.72 | 32 | 15.14 | 465 | 225 | 0.23 / 107.36 | 5 | 27 |
2 | 7 | 2014.08 | 40 | 14.74 | 3510 | 2069 | 2.29 / 109.43 | 27 | 75 |
3 | 13 | 1810.76 | 20 | 14.75 | 3228 | 952 | 3.25 / 110.38 | 5 | 81 |
4 | 13 | 1385.64 | 20 | 14.81 | 2531 | 750 | 4.00 / 111.13 | 5 | 89 |
5 | 13 | 928.16 | 20 | 14.89 | 1848 | 550 | 4.55 / 111.68 | 5 | 98 |
6 | 13 | 71.96 | 20 | 15.16 | 449 | 136 | 4.68 / 111.81 | 5 | 96 |
7 | 13 | 14.92 | 20 | 15.17 | 335 | 102 | 4.78 / 111.92 | 5 | 92 |
8 | 8 | 0.08 | 169 | 15.14 | 303 | 775 | 5.56 / 112.69 | 5 | 136 |
9 | 14 | 0.00 | 31 | 15.11 | 285 | 133 | 5.69 / 112.82 | 32 | -99 |
Average= | 5.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.32 | 32 | 15.15 | 448 | 217 | 0.22 / 101.70 | 5 | 28 |
2 | 7 | 2013.44 | 40 | 14.76 | 3492 | 2062 | 2.28 / 103.76 | 28 | 74 |
3 | 13 | 1933.36 | 20 | 14.74 | 3401 | 1003 | 3.28 / 104.77 | 5 | 78 |
4 | 13 | 1393.36 | 20 | 14.81 | 2557 | 757 | 4.04 / 105.52 | 5 | 88 |
5 | 13 | 755.60 | 20 | 14.95 | 1579 | 472 | 4.51 / 106.00 | 5 | 100 |
6 | 13 | 57.88 | 20 | 15.17 | 425 | 129 | 4.64 / 106.13 | 5 | 95 |
7 | 13 | 16.28 | 20 | 15.18 | 337 | 102 | 4.74 / 106.23 | 5 | 90 |
8 | 8 | 0.16 | 171 | 15.14 | 302 | 782 | 5.52 / 107.01 | 5 | 131 |
9 | 14 | 0.04 | 29 | 15.11 | 277 | 121 | 5.65 / 107.13 | 40 | -99 |
Average= | 5.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.64 | 32 | 15.15 | 447 | 217 | 0.22 / 96.10 | 5 | 27 |
2 | 7 | 2003.56 | 40 | 14.76 | 3488 | 2059 | 2.28 / 98.16 | 27 | 74 |
3 | 13 | 1907.92 | 20 | 14.76 | 3344 | 987 | 3.26 / 99.14 | 5 | 79 |
4 | 13 | 1269.16 | 20 | 14.85 | 2371 | 704 | 3.97 / 99.85 | 5 | 91 |
5 | 13 | 839.40 | 20 | 14.93 | 1700 | 508 | 4.47 / 100.36 | 5 | 101 |
6 | 13 | 45.16 | 20 | 15.18 | 398 | 121 | 4.60 / 100.48 | 5 | 93 |
7 | 13 | 28.56 | 20 | 15.18 | 360 | 109 | 4.71 / 100.59 | 5 | 93 |
8 | 8 | 0.24 | 167 | 15.15 | 300 | 759 | 5.46 / 101.34 | 5 | 131 |
9 | 14 | 0.12 | 33 | 15.12 | 283 | 141 | 5.61 / 101.49 | 35 | -99 |
Average= | 5.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.56 | 32 | 15.16 | 451 | 219 | 0.22 / 90.57 | 5 | 26 |
2 | 7 | 2013.00 | 40 | 14.76 | 3505 | 2069 | 2.29 / 92.64 | 26 | 74 |
3 | 13 | 1916.20 | 20 | 14.76 | 3363 | 993 | 3.28 / 93.63 | 5 | 79 |
4 | 13 | 1385.20 | 20 | 14.82 | 2532 | 750 | 4.03 / 94.38 | 5 | 89 |
5 | 13 | 713.12 | 20 | 14.97 | 1512 | 453 | 4.48 / 94.83 | 5 | 103 |
6 | 13 | 42.68 | 20 | 15.18 | 401 | 122 | 4.61 / 94.96 | 5 | 93 |
7 | 8 | 0.00 | 184 | 15.16 | 305 | 851 | 5.46 / 95.81 | 5 | 130 |
8 | 14 | -0.04 | 16 | 15.12 | 302 | 73 | 5.53 / 95.88 | 34 | 151 |
Average= | 5.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.96 | 32 | 15.15 | 451 | 219 | 0.22 / 85.05 | 5 | 27 |
2 | 7 | 2010.84 | 40 | 14.77 | 3500 | 2068 | 2.29 / 87.11 | 27 | 75 |
3 | 13 | 1921.16 | 20 | 14.75 | 3383 | 998 | 3.28 / 88.11 | 5 | 81 |
4 | 13 | 1166.68 | 20 | 14.88 | 2225 | 662 | 3.95 / 88.77 | 5 | 94 |
5 | 13 | 649.60 | 20 | 14.99 | 1407 | 422 | 4.37 / 89.20 | 5 | 103 |
6 | 13 | 49.28 | 20 | 15.19 | 414 | 126 | 4.49 / 89.32 | 5 | 93 |
7 | 13 | 17.60 | 20 | 15.19 | 346 | 105 | 4.60 / 89.43 | 5 | 95 |
8 | 8 | 0.04 | 167 | 15.15 | 308 | 779 | 5.38 / 90.21 | 5 | 133 |
9 | 14 | 0.00 | 33 | 15.12 | 289 | 144 | 5.52 / 90.35 | 31 | -99 |
Average= | 5.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.16 | 32 | 15.16 | 464 | 225 | 0.23 / 79.43 | 5 | 26 |
2 | 7 | 2003.64 | 40 | 14.77 | 3471 | 2051 | 2.28 / 81.48 | 26 | 76 |
3 | 13 | 1907.12 | 20 | 14.76 | 3353 | 990 | 3.27 / 82.47 | 5 | 81 |
4 | 13 | 1358.16 | 20 | 14.84 | 2496 | 741 | 4.01 / 83.21 | 5 | 91 |
5 | 13 | 704.44 | 20 | 14.98 | 1490 | 446 | 4.45 / 83.66 | 5 | 104 |
6 | 13 | 71.08 | 20 | 15.18 | 451 | 137 | 4.59 / 83.80 | 5 | 96 |
7 | 13 | 18.36 | 20 | 15.19 | 347 | 105 | 4.70 / 83.90 | 5 | 96 |
8 | 8 | 0.04 | 165 | 15.15 | 310 | 775 | 5.47 / 84.68 | 5 | 134 |
9 | 14 | 0.04 | 35 | 15.12 | 287 | 152 | 5.62 / 84.83 | 29 | -99 |
Average= | 4.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.28 | 32 | 15.17 | 440 | 214 | 0.21 / 74.01 | 5 | 26 |
2 | 7 | 2012.04 | 40 | 14.77 | 3491 | 2062 | 2.28 / 76.07 | 26 | 76 |
3 | 13 | 1712.00 | 20 | 14.81 | 3042 | 901 | 3.18 / 76.98 | 5 | 84 |
4 | 13 | 1195.48 | 20 | 14.88 | 2255 | 671 | 3.85 / 77.65 | 5 | 95 |
5 | 13 | 676.56 | 20 | 14.99 | 1445 | 433 | 4.28 / 78.08 | 5 | 103 |
6 | 13 | 47.28 | 20 | 15.19 | 404 | 123 | 4.40 / 78.20 | 5 | 94 |
7 | 13 | 12.16 | 20 | 15.20 | 332 | 101 | 4.51 / 78.30 | 5 | 95 |
8 | 8 | 0.08 | 167 | 15.16 | 301 | 762 | 5.27 / 79.07 | 5 | 133 |
9 | 14 | 0.00 | 33 | 15.13 | 280 | 140 | 5.41 / 79.21 | 38 | -99 |
Average= | 4.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.88 | 32 | 15.17 | 463 | 225 | 0.22 / 68.58 | 5 | 26 |
2 | 7 | 2007.84 | 40 | 14.78 | 3476 | 2055 | 2.28 / 70.63 | 26 | 76 |
3 | 13 | 1807.92 | 20 | 14.79 | 3199 | 946 | 3.23 / 71.58 | 5 | 82 |
4 | 13 | 1287.96 | 20 | 14.86 | 2394 | 711 | 3.94 / 72.29 | 5 | 94 |
5 | 13 | 748.64 | 20 | 14.98 | 1559 | 467 | 4.40 / 72.76 | 5 | 102 |
6 | 13 | 28.68 | 20 | 15.20 | 373 | 113 | 4.52 / 72.87 | 5 | 93 |
7 | 8 | 0.24 | 186 | 15.17 | 307 | 866 | 5.38 / 73.73 | 5 | 129 |
8 | 14 | -0.04 | 14 | 15.14 | 302 | 64 | 5.45 / 73.80 | 31 | 159 |
Average= | 4.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.32 | 32 | 15.18 | 447 | 217 | 0.22 / 62.96 | 5 | 27 |
2 | 7 | 2011.08 | 40 | 14.79 | 3472 | 2054 | 2.27 / 65.02 | 27 | 76 |
3 | 13 | 1918.48 | 20 | 14.78 | 3371 | 996 | 3.27 / 66.01 | 5 | 81 |
4 | 13 | 1362.36 | 20 | 14.85 | 2503 | 743 | 4.01 / 66.75 | 5 | 92 |
5 | 13 | 707.84 | 20 | 15.00 | 1492 | 448 | 4.46 / 67.20 | 5 | 102 |
6 | 13 | 65.24 | 20 | 15.19 | 437 | 133 | 4.59 / 67.34 | 5 | 96 |
7 | 13 | 20.92 | 20 | 15.20 | 354 | 108 | 4.70 / 67.44 | 5 | 96 |
8 | 8 | 0.08 | 163 | 15.17 | 303 | 749 | 5.45 / 68.19 | 5 | 130 |
9 | 14 | -0.04 | 37 | 15.14 | 283 | 159 | 5.61 / 68.35 | 30 | -99 |
Average= | 4.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.56 | 32 | 15.18 | 466 | 226 | 0.23 / 57.48 | 5 | 27 |
2 | 7 | 2003.28 | 40 | 14.80 | 3474 | 2057 | 2.28 / 59.53 | 11 | 76 |
3 | 13 | 1910.12 | 20 | 14.78 | 3356 | 992 | 3.28 / 60.53 | 5 | 80 |
4 | 13 | 1338.84 | 20 | 14.87 | 2466 | 733 | 4.01 / 61.26 | 5 | 92 |
5 | 13 | 691.88 | 20 | 15.00 | 1471 | 441 | 4.45 / 61.70 | 5 | 103 |
6 | 13 | 37.96 | 20 | 15.21 | 391 | 119 | 4.57 / 61.82 | 5 | 94 |
7 | 8 | 0.16 | 188 | 15.18 | 305 | 870 | 5.44 / 62.69 | 5 | 133 |
8 | 14 | 0.00 | 12 | 15.15 | 301 | 55 | 5.49 / 62.74 | 36 | 152 |
Average= | 4.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.08 | 32 | 15.18 | 447 | 217 | 0.22 / 51.92 | 5 | 27 |
2 | 7 | 2007.16 | 40 | 14.80 | 3477 | 2058 | 2.28 / 53.98 | 27 | 75 |
3 | 13 | 1917.24 | 20 | 14.78 | 3368 | 996 | 3.27 / 54.98 | 5 | 80 |
4 | 13 | 1159.08 | 20 | 14.91 | 2206 | 658 | 3.93 / 55.63 | 5 | 96 |
5 | 13 | 751.16 | 20 | 14.99 | 1561 | 468 | 4.40 / 56.10 | 5 | 102 |
6 | 13 | 41.64 | 20 | 15.21 | 395 | 120 | 4.52 / 56.22 | 5 | 95 |
7 | 13 | 9.60 | 20 | 15.21 | 334 | 102 | 4.62 / 56.32 | 5 | 97 |
8 | 8 | 0.24 | 165 | 15.18 | 308 | 771 | 5.39 / 57.10 | 5 | 129 |
9 | 14 | 0.00 | 35 | 15.14 | 291 | 154 | 5.54 / 57.25 | 32 | -99 |
Average= | 4.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.04 | 32 | 15.19 | 469 | 228 | 0.23 / 46.35 | 5 | 25 |
2 | 7 | 2013.68 | 40 | 14.80 | 3501 | 2073 | 2.30 / 48.42 | 25 | 77 |
3 | 13 | 1915.56 | 20 | 14.79 | 3357 | 993 | 3.29 / 49.41 | 5 | 81 |
4 | 13 | 1368.80 | 20 | 14.86 | 2517 | 748 | 4.04 / 50.16 | 5 | 92 |
5 | 13 | 813.08 | 20 | 14.97 | 1667 | 499 | 4.54 / 50.66 | 5 | 103 |
6 | 13 | 32.04 | 20 | 15.22 | 381 | 116 | 4.66 / 50.78 | 5 | 94 |
7 | 8 | 0.20 | 186 | 15.19 | 306 | 865 | 5.52 / 51.64 | 5 | 130 |
8 | 14 | -0.04 | 14 | 15.16 | 302 | 64 | 5.59 / 51.71 | 41 | 164 |
Average= | 4.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.76 | 31 | 15.19 | 467 | 220 | 0.22 / 40.73 | 5 | 26 |
2 | 7 | 2004.32 | 40 | 14.80 | 3482 | 2061 | 2.28 / 42.79 | 7 | 76 |
3 | 13 | 1908.76 | 20 | 14.79 | 3356 | 993 | 3.27 / 43.78 | 5 | 81 |
4 | 13 | 1241.68 | 20 | 14.90 | 2343 | 698 | 3.97 / 44.48 | 5 | 94 |
5 | 13 | 814.32 | 20 | 14.98 | 1671 | 501 | 4.47 / 44.98 | 5 | 101 |
6 | 13 | 41.20 | 20 | 15.22 | 397 | 121 | 4.59 / 45.10 | 5 | 94 |
7 | 13 | 12.80 | 20 | 15.22 | 336 | 102 | 4.70 / 45.20 | 5 | 94 |
8 | 8 | 0.08 | 161 | 15.19 | 306 | 748 | 5.44 / 45.95 | 5 | 131 |
9 | 14 | 0.00 | 39 | 15.15 | 286 | 169 | 5.61 / 46.12 | 27 | -99 |
Average= | 4.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.88 | 31 | 15.20 | 470 | 221 | 0.22 / 35.13 | 5 | 28 |
2 | 7 | 2009.12 | 40 | 14.81 | 3475 | 2059 | 2.28 / 37.19 | 28 | 77 |
3 | 13 | 1925.56 | 20 | 14.79 | 3372 | 997 | 3.28 / 38.18 | 5 | 81 |
4 | 13 | 1378.96 | 20 | 14.87 | 2520 | 749 | 4.03 / 38.93 | 5 | 92 |
5 | 13 | 718.76 | 20 | 15.01 | 1509 | 453 | 4.48 / 39.39 | 5 | 103 |
6 | 13 | 41.80 | 20 | 15.22 | 390 | 119 | 4.60 / 39.51 | 5 | 96 |
7 | 13 | 17.68 | 20 | 15.22 | 338 | 103 | 4.70 / 39.61 | 5 | 94 |
8 | 8 | 0.08 | 159 | 15.20 | 299 | 723 | 5.42 / 40.33 | 5 | 130 |
9 | 14 | 0.00 | 41 | 15.16 | 283 | 176 | 5.60 / 40.51 | 31 | -99 |
Average= | 4.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.44 | 31 | 15.19 | 472 | 222 | 0.22 / 29.52 | 5 | 26 |
2 | 7 | 2008.92 | 41 | 14.81 | 3494 | 2122 | 2.34 / 31.64 | 26 | 76 |
3 | 13 | 1914.24 | 20 | 14.81 | 3345 | 991 | 3.33 / 32.63 | 5 | 81 |
4 | 13 | 1275.44 | 20 | 14.89 | 2384 | 710 | 4.04 / 33.34 | 5 | 92 |
5 | 13 | 832.76 | 20 | 14.98 | 1696 | 508 | 4.55 / 33.85 | 5 | 101 |
6 | 13 | 38.32 | 20 | 15.22 | 397 | 121 | 4.67 / 33.97 | 5 | 94 |
7 | 8 | 0.12 | 191 | 15.20 | 308 | 894 | 5.57 / 34.87 | 5 | 136 |
8 | 14 | -0.04 | 9 | 15.17 | 306 | 42 | 5.61 / 34.91 | 34 | 145 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.88 | 30 | 15.21 | 473 | 216 | 0.22 / 23.89 | 5 | 28 |
2 | 3 | 1022.64 | 1 | 15.20 | 2088 | 32 | 0.25 / 23.93 | 5 | 18 |
3 | 7 | 2013.88 | 40 | 14.81 | 3499 | 2073 | 2.32 / 26.00 | 18 | 76 |
4 | 13 | 1822.04 | 20 | 14.83 | 3218 | 954 | 3.27 / 26.95 | 5 | 83 |
5 | 13 | 1202.48 | 20 | 14.92 | 2264 | 676 | 3.95 / 27.63 | 5 | 94 |
6 | 13 | 880.24 | 20 | 14.97 | 1772 | 531 | 4.48 / 28.16 | 5 | 101 |
7 | 13 | 48.88 | 20 | 15.22 | 411 | 125 | 4.61 / 28.28 | 5 | 94 |
8 | 13 | 14.24 | 20 | 15.23 | 332 | 101 | 4.71 / 28.38 | 5 | 92 |
9 | 8 | 0.12 | 171 | 15.20 | 303 | 788 | 5.49 / 29.17 | 5 | 130 |
10 | 14 | 0.08 | 29 | 15.16 | 285 | 125 | 5.62 / 29.30 | 35 | -99 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.84 | 31 | 15.23 | 463 | 219 | 0.22 / 18.40 | 5 | 28 |
2 | 7 | 2005.52 | 40 | 14.82 | 3469 | 2056 | 2.28 / 20.46 | 28 | 77 |
3 | 13 | 1808.04 | 20 | 14.83 | 3189 | 946 | 3.22 / 21.40 | 5 | 84 |
4 | 13 | 1292.08 | 20 | 14.91 | 2404 | 717 | 3.94 / 22.12 | 5 | 94 |
5 | 13 | 644.12 | 20 | 15.05 | 1396 | 420 | 4.36 / 22.54 | 5 | 103 |
6 | 13 | 51.08 | 20 | 15.24 | 409 | 125 | 4.48 / 22.66 | 5 | 95 |
7 | 13 | 14.32 | 20 | 15.24 | 332 | 101 | 4.58 / 22.76 | 5 | 95 |
8 | 8 | 0.08 | 172 | 15.21 | 302 | 790 | 5.37 / 23.55 | 5 | 131 |
9 | 14 | -0.08 | 28 | 15.17 | 289 | 123 | 5.50 / 23.68 | 38 | -99 |
Average= | 3.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.68 | 30 | 15.22 | 467 | 213 | 0.21 / 13.73 | 5 | 29 |
2 | 7 | 1519.20 | 40 | 15.00 | 2713 | 1628 | 1.84 / 15.36 | 29 | 79 |
3 | 13 | 1438.48 | 20 | 15.00 | 2607 | 782 | 2.62 / 16.14 | 5 | 84 |
4 | 13 | 1037.00 | 20 | 15.03 | 2009 | 604 | 3.23 / 16.74 | 5 | 93 |
5 | 13 | 598.28 | 20 | 15.11 | 1312 | 396 | 3.62 / 17.14 | 5 | 98 |
6 | 13 | 32.84 | 20 | 15.27 | 378 | 115 | 3.74 / 17.26 | 5 | 92 |
7 | 8 | 0.20 | 186 | 15.24 | 304 | 862 | 4.60 / 18.12 | 5 | 133 |
8 | 14 | 0.04 | 14 | 15.21 | 301 | 64 | 4.66 / 18.18 | 30 | 152 |
Average= | 3.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.60 | 30 | 15.22 | 470 | 215 | 0.21 / 9.09 | 5 | 30 |
2 | 7 | 1508.20 | 41 | 14.99 | 2718 | 1670 | 1.89 / 10.76 | 30 | 81 |
3 | 13 | 1437.60 | 20 | 14.99 | 2612 | 783 | 2.67 / 11.54 | 5 | 83 |
4 | 13 | 950.96 | 20 | 15.05 | 1876 | 565 | 3.23 / 12.11 | 5 | 94 |
5 | 13 | 522.80 | 20 | 15.13 | 1186 | 359 | 3.59 / 12.47 | 5 | 101 |
6 | 13 | 34.04 | 20 | 15.26 | 381 | 116 | 3.71 / 12.58 | 5 | 93 |
7 | 8 | 0.24 | 187 | 15.24 | 306 | 872 | 4.58 / 13.46 | 5 | 131 |
8 | 14 | 0.04 | 13 | 15.21 | 303 | 60 | 4.64 / 13.52 | 35 | 151 |
Average= | 3.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.40 | 31 | 15.26 | 477 | 226 | 0.23 / 4.48 | 5 | 32 |
2 | 7 | 1508.96 | 40 | 15.00 | 2703 | 1622 | 1.85 / 6.10 | 32 | 81 |
3 | 13 | 1436.48 | 20 | 14.99 | 2617 | 785 | 2.63 / 6.89 | 5 | 84 |
4 | 13 | 1023.52 | 20 | 15.03 | 1987 | 597 | 3.23 / 7.49 | 5 | 92 |
5 | 13 | 479.28 | 20 | 15.14 | 1117 | 338 | 3.57 / 7.82 | 5 | 97 |
6 | 13 | 32.16 | 20 | 15.26 | 376 | 115 | 3.68 / 7.94 | 5 | 93 |
7 | 8 | 0.32 | 188 | 15.23 | 308 | 882 | 4.56 / 8.82 | 5 | 131 |
8 | 14 | 0.04 | 12 | 15.20 | 304 | 55 | 4.62 / 8.88 | 28 | 152 |
Average= | 2.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.92 | 31 | 15.45 | 444 | 213 | 0.21 / 1.68 | 5 | 25 |
2 | 3 | 943.96 | -1 | 15.58 | 0 | 0 | 0.00 / 1.68 | 5 | 25 |
3 | 7 | 999.44 | 40 | 15.13 | 1944 | 1177 | 1.39 / 2.86 | 25 | 94 |
4 | 13 | 463.92 | 20 | 15.24 | 1087 | 331 | 1.72 / 3.19 | 5 | 97 |
5 | 13 | 30.60 | 20 | 15.33 | 378 | 116 | 1.84 / 3.31 | 5 | 93 |
6 | 8 | 0.32 | 189 | 15.30 | 311 | 899 | 2.74 / 4.21 | 5 | 135 |
7 | 14 | 0.08 | 11 | 15.26 | 307 | 52 | 2.79 / 4.26 | 33 | 147 |
Average= | 2.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.52 | 30 | 15.59 | 443 | 207 | 0.21 / 0.21 | 5 | 24 |
2 | 7 | 116.28 | 40 | 15.57 | 449 | 280 | 0.49 / 0.49 | 24 | 29 |
3 | 13 | 61.88 | 20 | 15.57 | 368 | 115 | 0.60 / 0.60 | 5 | 36 |
4 | 13 | 15.24 | 20 | 15.56 | 286 | 89 | 0.69 / 0.69 | 5 | 41 |
5 | 8 | 0.08 | 193 | 15.53 | 251 | 752 | 1.44 / 1.44 | 5 | 173 |
6 | 14 | -0.08 | 7 | 15.50 | 245 | 27 | 1.47 / 1.47 | 113 | -99 |
Average= | 1.47 (KJ/cycle) |