SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.80 | 37 | 14.96 | 454 | 251 | 0.25 / 607.74 | 6 | 7 |
2 | 7 | 2005.76 | 40 | 14.58 | 3031 | 1768 | 2.02 / 609.51 | 7 | 21 |
3 | 13 | 1922.32 | 20 | 14.55 | 2937 | 855 | 2.87 / 610.37 | 5 | 23 |
4 | 13 | 1523.76 | 20 | 14.54 | 2438 | 709 | 3.58 / 611.08 | 5 | 31 |
5 | 13 | 996.28 | 20 | 14.65 | 1738 | 509 | 4.09 / 611.58 | 5 | 36 |
6 | 13 | 544.64 | 20 | 14.79 | 1130 | 334 | 4.43 / 611.92 | 5 | 37 |
7 | 13 | 40.60 | 20 | 14.97 | 400 | 120 | 4.55 / 612.04 | 5 | 27 |
8 | 8 | -0.08 | 267 | 14.92 | 328 | 1307 | 5.85 / 613.35 | 6 | 138 |
Average= | 6.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.60 | 37 | 14.94 | 436 | 241 | 0.24 / 602.01 | 6 | 6 |
2 | 7 | 2004.36 | 40 | 14.59 | 3032 | 1769 | 2.01 / 603.78 | 6 | 22 |
3 | 13 | 1910.36 | 20 | 14.56 | 2913 | 848 | 2.86 / 604.63 | 5 | 24 |
4 | 13 | 1602.36 | 20 | 14.53 | 2531 | 736 | 3.59 / 605.37 | 5 | 31 |
5 | 13 | 1044.12 | 20 | 14.64 | 1800 | 527 | 4.12 / 605.89 | 5 | 36 |
6 | 13 | 177.80 | 20 | 14.95 | 605 | 181 | 4.30 / 606.08 | 5 | 35 |
7 | 13 | 33.92 | 20 | 14.99 | 393 | 118 | 4.42 / 606.19 | 6 | 32 |
8 | 8 | 0.12 | 266 | 14.94 | 327 | 1300 | 5.72 / 607.49 | 6 | 155 |
Average= | 6.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.88 | 37 | 14.96 | 441 | 244 | 0.24 / 595.95 | 6 | 6 |
2 | 7 | 2019.16 | 40 | 14.59 | 3056 | 1783 | 2.03 / 597.74 | 6 | 22 |
3 | 13 | 1943.52 | 20 | 14.55 | 2962 | 862 | 2.89 / 598.60 | 5 | 25 |
4 | 13 | 1746.80 | 20 | 14.50 | 2715 | 787 | 3.68 / 599.39 | 5 | 26 |
5 | 13 | 1264.12 | 20 | 14.57 | 2100 | 612 | 4.29 / 600.00 | 5 | 34 |
6 | 13 | 551.76 | 20 | 14.79 | 1139 | 337 | 4.63 / 600.34 | 5 | 39 |
7 | 13 | 41.28 | 20 | 14.98 | 403 | 121 | 4.75 / 600.46 | 5 | 20 |
8 | 8 | 0.00 | 270 | 14.92 | 327 | 1317 | 6.06 / 601.77 | 6 | 144 |
Average= | 6.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.04 | 37 | 14.96 | 428 | 237 | 0.24 / 590.32 | 6 | 11 |
2 | 7 | 2006.20 | 40 | 14.59 | 3037 | 1772 | 2.01 / 592.10 | 11 | 21 |
3 | 13 | 1920.36 | 20 | 14.55 | 2929 | 852 | 2.86 / 592.95 | 5 | 24 |
4 | 13 | 1512.80 | 20 | 14.55 | 2418 | 704 | 3.57 / 593.65 | 5 | 32 |
5 | 13 | 959.60 | 20 | 14.67 | 1685 | 494 | 4.06 / 594.15 | 5 | 33 |
6 | 13 | 205.40 | 20 | 14.93 | 645 | 193 | 4.25 / 594.34 | 5 | 40 |
7 | 13 | 44.32 | 20 | 14.98 | 395 | 118 | 4.37 / 594.46 | 5 | 34 |
8 | 8 | 0.00 | 263 | 14.94 | 319 | 1253 | 5.62 / 595.71 | 6 | 133 |
Average= | 6.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.00 | 37 | 14.95 | 430 | 238 | 0.24 / 584.71 | 6 | 6 |
2 | 7 | 2010.76 | 40 | 14.58 | 3048 | 1778 | 2.02 / 586.49 | 6 | 21 |
3 | 13 | 1932.00 | 20 | 14.55 | 2951 | 859 | 2.87 / 587.35 | 5 | 26 |
4 | 13 | 1399.80 | 20 | 14.59 | 2279 | 665 | 3.54 / 588.01 | 5 | 32 |
5 | 13 | 993.68 | 20 | 14.65 | 1737 | 509 | 4.05 / 588.52 | 5 | 35 |
6 | 13 | 220.36 | 20 | 14.92 | 674 | 201 | 4.25 / 588.72 | 5 | 32 |
7 | 13 | 56.24 | 20 | 14.98 | 415 | 124 | 4.37 / 588.85 | 5 | 19 |
8 | 8 | 0.04 | 261 | 14.94 | 318 | 1240 | 5.61 / 590.09 | 6 | 153 |
Average= | 6.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.84 | 37 | 14.96 | 442 | 245 | 0.24 / 578.94 | 6 | 6 |
2 | 7 | 2003.48 | 41 | 14.59 | 3035 | 1816 | 2.06 / 580.76 | 6 | 20 |
3 | 13 | 1913.12 | 20 | 14.56 | 2918 | 850 | 2.91 / 581.61 | 5 | 24 |
4 | 13 | 1485.08 | 20 | 14.56 | 2384 | 694 | 3.60 / 582.30 | 5 | 31 |
5 | 13 | 1046.40 | 20 | 14.64 | 1802 | 528 | 4.13 / 582.83 | 5 | 34 |
6 | 13 | 364.08 | 20 | 14.87 | 874 | 260 | 4.39 / 583.09 | 5 | 33 |
7 | 13 | 33.88 | 20 | 14.99 | 385 | 115 | 4.51 / 583.20 | 5 | 30 |
8 | 8 | 0.16 | 263 | 14.93 | 323 | 1268 | 5.78 / 584.47 | 6 | 138 |
Average= | 6.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.04 | 37 | 14.96 | 440 | 244 | 0.24 / 573.33 | 6 | 6 |
2 | 7 | 2003.20 | 40 | 14.60 | 3025 | 1767 | 2.01 / 575.10 | 6 | 21 |
3 | 13 | 1914.56 | 20 | 14.56 | 2929 | 853 | 2.86 / 575.95 | 5 | 25 |
4 | 13 | 1484.24 | 20 | 14.57 | 2377 | 693 | 3.56 / 576.65 | 5 | 30 |
5 | 13 | 1044.08 | 20 | 14.65 | 1799 | 527 | 4.08 / 577.17 | 5 | 34 |
6 | 13 | 161.12 | 20 | 14.96 | 578 | 173 | 4.26 / 577.35 | 5 | 29 |
7 | 13 | 36.88 | 20 | 14.99 | 394 | 118 | 4.37 / 577.46 | 5 | 29 |
8 | 8 | 0.04 | 257 | 14.95 | 321 | 1233 | 5.61 / 578.70 | 6 | 137 |
Average= | 6.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.40 | 37 | 14.95 | 444 | 246 | 0.25 / 567.72 | 6 | 6 |
2 | 7 | 2005.32 | 40 | 14.59 | 3034 | 1771 | 2.02 / 569.49 | 6 | 22 |
3 | 13 | 1912.52 | 20 | 14.57 | 2920 | 851 | 2.87 / 570.34 | 5 | 26 |
4 | 13 | 1598.68 | 20 | 14.55 | 2529 | 736 | 3.60 / 571.07 | 5 | 31 |
5 | 13 | 821.48 | 20 | 14.72 | 1508 | 444 | 4.05 / 571.52 | 5 | 34 |
6 | 13 | 164.88 | 20 | 14.95 | 590 | 176 | 4.22 / 571.69 | 5 | 31 |
7 | 13 | 35.80 | 20 | 14.99 | 386 | 116 | 4.34 / 571.81 | 5 | 36 |
8 | 8 | 0.04 | 263 | 14.94 | 326 | 1281 | 5.62 / 573.09 | 6 | 133 |
Average= | 6.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.36 | 37 | 14.96 | 437 | 242 | 0.24 / 561.92 | 6 | 6 |
2 | 7 | 2016.04 | 41 | 14.59 | 3047 | 1823 | 2.06 / 563.74 | 6 | 22 |
3 | 13 | 1938.44 | 20 | 14.56 | 2949 | 859 | 2.92 / 564.60 | 5 | 28 |
4 | 13 | 1527.12 | 20 | 14.56 | 2430 | 708 | 3.63 / 565.31 | 5 | 31 |
5 | 13 | 1096.32 | 20 | 14.63 | 1869 | 547 | 4.18 / 565.86 | 5 | 34 |
6 | 13 | 299.48 | 20 | 14.90 | 781 | 233 | 4.41 / 566.09 | 5 | 33 |
7 | 13 | 39.56 | 20 | 14.99 | 400 | 120 | 4.53 / 566.21 | 6 | 29 |
8 | 8 | 0.04 | 259 | 14.94 | 326 | 1261 | 5.79 / 567.47 | 6 | 136 |
Average= | 7.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.84 | 37 | 14.97 | 454 | 251 | 0.25 / 556.27 | 6 | 8 |
2 | 7 | 2012.60 | 40 | 14.59 | 3041 | 1775 | 2.03 / 558.05 | 8 | 23 |
3 | 13 | 1920.52 | 20 | 14.57 | 2931 | 854 | 2.88 / 558.90 | 5 | 24 |
4 | 13 | 1501.56 | 20 | 14.56 | 2407 | 701 | 3.58 / 559.60 | 5 | 31 |
5 | 13 | 855.36 | 20 | 14.71 | 1559 | 459 | 4.04 / 560.06 | 5 | 35 |
6 | 13 | 215.00 | 20 | 14.93 | 661 | 197 | 4.24 / 560.26 | 5 | 32 |
7 | 13 | 53.88 | 20 | 14.99 | 417 | 125 | 4.36 / 560.38 | 6 | 24 |
8 | 8 | 0.04 | 263 | 14.94 | 329 | 1293 | 5.65 / 561.68 | 6 | 150 |
Average= | 7.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.64 | 37 | 14.95 | 468 | 259 | 0.26 / 550.54 | 6 | 6 |
2 | 7 | 2004.56 | 40 | 14.59 | 3035 | 1771 | 2.03 / 552.31 | 6 | 21 |
3 | 13 | 1916.96 | 20 | 14.56 | 2927 | 852 | 2.88 / 553.16 | 5 | 25 |
4 | 13 | 1719.04 | 20 | 14.52 | 2680 | 778 | 3.66 / 553.94 | 5 | 29 |
5 | 13 | 1136.40 | 20 | 14.63 | 1916 | 561 | 4.22 / 554.50 | 5 | 33 |
6 | 13 | 64.56 | 20 | 15.00 | 441 | 132 | 4.35 / 554.63 | 5 | 26 |
7 | 13 | 20.40 | 20 | 15.01 | 376 | 113 | 4.47 / 554.74 | 6 | 31 |
8 | 8 | 0.00 | 257 | 14.95 | 333 | 1279 | 5.75 / 556.02 | 6 | 143 |
Average= | 7.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.36 | 37 | 14.97 | 452 | 250 | 0.25 / 544.65 | 6 | 6 |
2 | 7 | 2008.32 | 40 | 14.60 | 3039 | 1775 | 2.03 / 546.42 | 6 | 23 |
3 | 13 | 1926.72 | 20 | 14.57 | 2935 | 855 | 2.88 / 547.28 | 5 | 27 |
4 | 13 | 1503.44 | 20 | 14.56 | 2414 | 703 | 3.58 / 547.98 | 5 | 32 |
5 | 13 | 1171.68 | 20 | 14.61 | 1969 | 575 | 4.16 / 548.56 | 5 | 33 |
6 | 13 | 448.20 | 20 | 14.84 | 997 | 296 | 4.45 / 548.85 | 5 | 38 |
7 | 13 | 23.48 | 20 | 14.99 | 378 | 113 | 4.57 / 548.96 | 6 | 30 |
8 | 8 | 0.04 | 263 | 14.94 | 334 | 1312 | 5.88 / 550.28 | 6 | 151 |
Average= | 7.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.92 | 37 | 14.96 | 460 | 255 | 0.25 / 538.96 | 6 | 6 |
2 | 7 | 2005.16 | 40 | 14.60 | 3040 | 1775 | 2.03 / 540.73 | 6 | 18 |
3 | 13 | 1921.40 | 20 | 14.57 | 2932 | 854 | 2.88 / 541.59 | 5 | 22 |
4 | 13 | 1515.68 | 20 | 14.56 | 2427 | 707 | 3.59 / 542.30 | 5 | 32 |
5 | 13 | 878.96 | 20 | 14.71 | 1580 | 465 | 4.06 / 542.76 | 5 | 36 |
6 | 13 | 332.88 | 20 | 14.89 | 833 | 248 | 4.30 / 543.01 | 5 | 32 |
7 | 13 | 22.92 | 20 | 15.00 | 377 | 113 | 4.42 / 543.12 | 6 | 33 |
8 | 8 | -0.04 | 261 | 14.94 | 327 | 1275 | 5.69 / 544.40 | 6 | 150 |
Average= | 7.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.00 | 37 | 14.96 | 462 | 256 | 0.26 / 533.21 | 6 | 6 |
2 | 7 | 2004.32 | 40 | 14.61 | 3028 | 1770 | 2.03 / 534.98 | 6 | 22 |
3 | 13 | 1912.48 | 20 | 14.58 | 2921 | 852 | 2.88 / 535.83 | 5 | 26 |
4 | 13 | 1606.64 | 20 | 14.55 | 2538 | 739 | 3.62 / 536.57 | 5 | 32 |
5 | 13 | 839.56 | 20 | 14.73 | 1537 | 453 | 4.07 / 537.02 | 5 | 34 |
6 | 13 | 392.84 | 20 | 14.87 | 913 | 272 | 4.34 / 537.29 | 5 | 35 |
7 | 13 | 37.12 | 20 | 14.99 | 398 | 119 | 4.46 / 537.41 | 6 | 26 |
8 | 8 | 0.00 | 261 | 14.94 | 331 | 1291 | 5.75 / 538.70 | 6 | 134 |
Average= | 7.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.96 | 37 | 14.97 | 467 | 259 | 0.26 / 527.36 | 6 | 19 |
2 | 7 | 2006.40 | 40 | 14.60 | 3032 | 1771 | 2.03 / 529.13 | 19 | 17 |
3 | 13 | 1924.56 | 20 | 14.57 | 2936 | 856 | 2.88 / 529.99 | 5 | 22 |
4 | 13 | 1611.12 | 20 | 14.54 | 2542 | 739 | 3.62 / 530.73 | 5 | 25 |
5 | 13 | 1049.68 | 20 | 14.65 | 1810 | 530 | 4.15 / 531.26 | 5 | 31 |
6 | 13 | 397.76 | 20 | 14.87 | 924 | 275 | 4.43 / 531.53 | 5 | 32 |
7 | 13 | 33.20 | 20 | 14.99 | 394 | 118 | 4.55 / 531.65 | 5 | 52 |
8 | 8 | -0.04 | 264 | 14.94 | 330 | 1302 | 5.85 / 532.95 | 6 | 142 |
Average= | 7.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.84 | 37 | 14.95 | 449 | 248 | 0.25 / 521.64 | 6 | 6 |
2 | 7 | 2004.12 | 40 | 14.60 | 3040 | 1775 | 2.02 / 523.41 | 6 | 19 |
3 | 13 | 1916.36 | 20 | 14.58 | 2925 | 853 | 2.88 / 524.26 | 5 | 28 |
4 | 13 | 1611.88 | 20 | 14.55 | 2546 | 741 | 3.62 / 525.00 | 5 | 32 |
5 | 13 | 1161.32 | 20 | 14.62 | 1953 | 571 | 4.19 / 525.58 | 5 | 33 |
6 | 13 | 89.84 | 20 | 14.99 | 484 | 145 | 4.33 / 525.72 | 5 | 6 |
7 | 8 | 0.00 | 278 | 14.96 | 333 | 1385 | 5.72 / 527.11 | 6 | 132 |
Average= | 7.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.76 | 37 | 14.95 | 467 | 258 | 0.26 / 516.01 | 6 | 9 |
2 | 7 | 2017.16 | 40 | 14.59 | 3050 | 1780 | 2.04 / 517.79 | 9 | 22 |
3 | 13 | 1929.80 | 20 | 14.57 | 2947 | 859 | 2.90 / 518.64 | 5 | 25 |
4 | 13 | 1311.24 | 20 | 14.62 | 2149 | 628 | 3.53 / 519.27 | 5 | 31 |
5 | 13 | 901.12 | 20 | 14.70 | 1622 | 477 | 4.00 / 519.75 | 5 | 36 |
6 | 13 | 241.36 | 20 | 14.93 | 696 | 208 | 4.21 / 519.96 | 5 | 32 |
7 | 13 | 61.44 | 20 | 14.98 | 434 | 130 | 4.34 / 520.09 | 5 | 28 |
8 | 8 | -0.04 | 265 | 14.94 | 328 | 1299 | 5.64 / 521.39 | 6 | 131 |
Average= | 7.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.96 | 37 | 14.95 | 461 | 255 | 0.26 / 510.26 | 6 | 7 |
2 | 7 | 2015.92 | 40 | 14.60 | 3059 | 1786 | 2.04 / 512.05 | 7 | 22 |
3 | 13 | 1928.96 | 20 | 14.57 | 2948 | 859 | 2.90 / 512.91 | 5 | 24 |
4 | 13 | 1502.76 | 20 | 14.57 | 2408 | 702 | 3.60 / 513.61 | 5 | 29 |
5 | 13 | 970.40 | 20 | 14.68 | 1703 | 500 | 4.10 / 514.11 | 5 | 34 |
6 | 13 | 301.40 | 20 | 14.90 | 788 | 235 | 4.34 / 514.34 | 5 | 33 |
7 | 13 | 40.52 | 20 | 14.99 | 407 | 122 | 4.46 / 514.47 | 5 | 22 |
8 | 8 | 0.04 | 263 | 14.94 | 326 | 1281 | 5.74 / 515.75 | 6 | 131 |
Average= | 7.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.24 | 37 | 14.96 | 444 | 246 | 0.25 / 504.32 | 6 | 8 |
2 | 7 | 2010.00 | 40 | 14.60 | 3041 | 1776 | 2.02 / 506.10 | 8 | 23 |
3 | 13 | 1912.92 | 20 | 14.57 | 2931 | 854 | 2.88 / 506.95 | 5 | 26 |
4 | 13 | 1480.20 | 20 | 14.58 | 2374 | 692 | 3.57 / 507.64 | 5 | 31 |
5 | 13 | 1029.32 | 20 | 14.66 | 1787 | 524 | 4.09 / 508.17 | 5 | 36 |
6 | 13 | 681.48 | 20 | 14.75 | 1323 | 390 | 4.48 / 508.56 | 5 | 37 |
7 | 13 | 87.68 | 20 | 14.97 | 474 | 142 | 4.62 / 508.70 | 5 | 29 |
8 | 8 | 0.04 | 267 | 14.94 | 328 | 1308 | 5.93 / 510.01 | 6 | 146 |
Average= | 7.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.52 | 37 | 14.97 | 446 | 247 | 0.25 / 498.65 | 6 | 9 |
2 | 7 | 2007.76 | 40 | 14.60 | 3039 | 1775 | 2.02 / 500.43 | 16 | 21 |
3 | 13 | 1911.72 | 20 | 14.58 | 2930 | 854 | 2.88 / 501.28 | 5 | 25 |
4 | 13 | 1384.08 | 20 | 14.60 | 2251 | 657 | 3.53 / 501.94 | 5 | 32 |
5 | 13 | 1063.76 | 20 | 14.64 | 1835 | 537 | 4.07 / 502.48 | 5 | 36 |
6 | 13 | 299.20 | 20 | 14.91 | 778 | 232 | 4.30 / 502.71 | 5 | 34 |
7 | 8 | 0.08 | 285 | 14.95 | 321 | 1368 | 5.67 / 504.08 | 6 | 147 |
Average= | 7.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.68 | 37 | 14.96 | 462 | 256 | 0.26 / 492.95 | 6 | 6 |
2 | 7 | 2007.20 | 40 | 14.61 | 3034 | 1773 | 2.03 / 494.72 | 6 | 23 |
3 | 13 | 1920.40 | 20 | 14.58 | 2932 | 855 | 2.88 / 495.57 | 5 | 23 |
4 | 13 | 1614.40 | 20 | 14.55 | 2536 | 738 | 3.62 / 496.31 | 5 | 31 |
5 | 13 | 982.12 | 20 | 14.68 | 1721 | 505 | 4.13 / 496.82 | 5 | 35 |
6 | 13 | 200.36 | 20 | 14.95 | 637 | 190 | 4.32 / 497.01 | 5 | 33 |
7 | 13 | 43.48 | 20 | 15.00 | 407 | 122 | 4.44 / 497.13 | 6 | 29 |
8 | 8 | 0.00 | 261 | 14.95 | 327 | 1276 | 5.72 / 498.40 | 6 | 132 |
Average= | 7.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.12 | 37 | 14.96 | 468 | 259 | 0.26 / 487.20 | 6 | 7 |
2 | 7 | 2004.40 | 40 | 14.61 | 3031 | 1771 | 2.03 / 488.97 | 16 | 21 |
3 | 13 | 1912.48 | 20 | 14.59 | 2913 | 850 | 2.88 / 489.82 | 5 | 25 |
4 | 13 | 1503.92 | 20 | 14.58 | 2395 | 698 | 3.58 / 490.52 | 5 | 32 |
5 | 13 | 986.64 | 20 | 14.68 | 1724 | 506 | 4.08 / 491.02 | 5 | 35 |
6 | 13 | 430.04 | 20 | 14.86 | 970 | 288 | 4.37 / 491.31 | 5 | 34 |
7 | 8 | 0.52 | 282 | 14.95 | 327 | 1379 | 5.75 / 492.69 | 6 | 140 |
Average= | 7.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.04 | 37 | 14.96 | 457 | 253 | 0.25 / 481.61 | 6 | 7 |
2 | 7 | 2010.04 | 40 | 14.61 | 3032 | 1772 | 2.02 / 483.38 | 7 | 21 |
3 | 13 | 1818.44 | 20 | 14.59 | 2800 | 817 | 2.84 / 484.20 | 5 | 26 |
4 | 13 | 1521.36 | 20 | 14.58 | 2422 | 706 | 3.55 / 484.91 | 5 | 29 |
5 | 13 | 886.92 | 20 | 14.71 | 1596 | 470 | 4.02 / 485.38 | 5 | 35 |
6 | 13 | 131.04 | 20 | 14.98 | 546 | 164 | 4.18 / 485.54 | 5 | 23 |
7 | 8 | 0.08 | 278 | 14.96 | 336 | 1397 | 5.58 / 486.94 | 6 | 132 |
Average= | 7.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.48 | 37 | 14.96 | 465 | 257 | 0.26 / 475.99 | 6 | 6 |
2 | 7 | 2011.68 | 40 | 14.60 | 3043 | 1777 | 2.03 / 477.77 | 13 | 20 |
3 | 13 | 1922.28 | 20 | 14.58 | 2936 | 856 | 2.89 / 478.63 | 5 | 26 |
4 | 13 | 1504.04 | 20 | 14.58 | 2403 | 701 | 3.59 / 479.33 | 5 | 31 |
5 | 13 | 885.20 | 20 | 14.71 | 1588 | 467 | 4.06 / 479.79 | 5 | 34 |
6 | 13 | 158.44 | 20 | 14.96 | 579 | 173 | 4.23 / 479.97 | 5 | 32 |
7 | 8 | 0.08 | 282 | 14.96 | 330 | 1392 | 5.62 / 481.36 | 6 | 132 |
Average= | 7.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.36 | 37 | 14.95 | 453 | 251 | 0.25 / 470.32 | 6 | 6 |
2 | 7 | 2006.92 | 40 | 14.60 | 3039 | 1775 | 2.03 / 472.10 | 6 | 22 |
3 | 13 | 1915.20 | 20 | 14.58 | 2928 | 854 | 2.88 / 472.95 | 5 | 23 |
4 | 13 | 1294.28 | 20 | 14.63 | 2142 | 627 | 3.51 / 473.58 | 5 | 32 |
5 | 13 | 1200.44 | 20 | 14.61 | 2010 | 587 | 4.09 / 474.17 | 5 | 34 |
6 | 13 | 201.32 | 20 | 14.95 | 640 | 191 | 4.28 / 474.36 | 5 | 28 |
7 | 13 | 22.64 | 20 | 15.01 | 375 | 113 | 4.40 / 474.47 | 6 | 29 |
8 | 8 | 0.04 | 257 | 14.95 | 329 | 1264 | 5.66 / 475.73 | 6 | 130 |
Average= | 7.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.68 | 37 | 14.96 | 455 | 252 | 0.25 / 464.56 | 6 | 6 |
2 | 7 | 2014.60 | 40 | 14.61 | 3045 | 1779 | 2.03 / 466.34 | 6 | 21 |
3 | 13 | 1926.84 | 20 | 14.57 | 2951 | 860 | 2.89 / 467.20 | 5 | 24 |
4 | 13 | 1386.08 | 20 | 14.61 | 2264 | 662 | 3.55 / 467.86 | 5 | 31 |
5 | 13 | 949.16 | 20 | 14.69 | 1683 | 494 | 4.05 / 468.36 | 5 | 35 |
6 | 13 | 397.12 | 20 | 14.87 | 923 | 275 | 4.32 / 468.63 | 5 | 35 |
7 | 13 | 67.68 | 20 | 14.98 | 452 | 135 | 4.46 / 468.77 | 5 | 27 |
8 | 8 | 0.12 | 263 | 14.94 | 333 | 1308 | 5.77 / 470.07 | 6 | 147 |
Average= | 7.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.32 | 37 | 14.96 | 447 | 247 | 0.25 / 458.76 | 6 | 8 |
2 | 7 | 2012.48 | 40 | 14.61 | 3045 | 1779 | 2.03 / 460.54 | 8 | 20 |
3 | 13 | 1915.68 | 20 | 14.58 | 2942 | 858 | 2.88 / 461.39 | 5 | 27 |
4 | 13 | 1608.32 | 20 | 14.56 | 2544 | 741 | 3.63 / 462.13 | 5 | 29 |
5 | 13 | 833.96 | 20 | 14.74 | 1516 | 447 | 4.07 / 462.58 | 5 | 35 |
6 | 13 | 516.72 | 20 | 14.83 | 1087 | 322 | 4.39 / 462.90 | 5 | 36 |
7 | 13 | 32.32 | 20 | 15.00 | 388 | 116 | 4.51 / 463.02 | 6 | 20 |
8 | 8 | 0.00 | 261 | 14.95 | 330 | 1288 | 5.80 / 464.31 | 6 | 141 |
Average= | 7.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.64 | 37 | 14.97 | 450 | 249 | 0.25 / 452.88 | 6 | 8 |
2 | 7 | 2010.44 | 40 | 14.61 | 3049 | 1782 | 2.03 / 454.66 | 16 | 22 |
3 | 13 | 1938.96 | 20 | 14.57 | 2958 | 862 | 2.89 / 455.52 | 5 | 25 |
4 | 13 | 1507.60 | 20 | 14.58 | 2413 | 704 | 3.60 / 456.22 | 5 | 29 |
5 | 13 | 1055.08 | 20 | 14.66 | 1819 | 533 | 4.13 / 456.76 | 5 | 36 |
6 | 13 | 584.92 | 20 | 14.79 | 1184 | 350 | 4.48 / 457.11 | 5 | 37 |
7 | 13 | 44.76 | 20 | 14.99 | 405 | 121 | 4.60 / 457.23 | 6 | 30 |
8 | 8 | -0.04 | 263 | 14.94 | 326 | 1281 | 5.88 / 458.51 | 6 | 136 |
Average= | 7.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.48 | 36 | 14.96 | 456 | 246 | 0.25 / 447.01 | 6 | 6 |
2 | 7 | 2003.52 | 40 | 14.62 | 3038 | 1777 | 2.02 / 448.78 | 6 | 24 |
3 | 13 | 1922.56 | 20 | 14.58 | 2944 | 858 | 2.88 / 449.64 | 5 | 24 |
4 | 13 | 1829.96 | 20 | 14.53 | 2819 | 819 | 3.70 / 450.46 | 5 | 26 |
5 | 13 | 895.28 | 20 | 14.72 | 1605 | 473 | 4.17 / 450.93 | 5 | 35 |
6 | 13 | 462.36 | 20 | 14.85 | 1020 | 303 | 4.48 / 451.24 | 5 | 36 |
7 | 8 | 0.12 | 280 | 14.96 | 332 | 1391 | 5.87 / 452.63 | 6 | 133 |
Average= | 7.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.84 | 37 | 14.96 | 446 | 247 | 0.25 / 441.23 | 6 | 7 |
2 | 7 | 2009.04 | 40 | 14.61 | 3041 | 1777 | 2.02 / 443.01 | 7 | 24 |
3 | 13 | 1931.24 | 20 | 14.58 | 2947 | 859 | 2.88 / 443.87 | 5 | 26 |
4 | 13 | 1634.56 | 20 | 14.55 | 2570 | 748 | 3.63 / 444.62 | 5 | 30 |
5 | 13 | 1081.56 | 20 | 14.65 | 1865 | 546 | 4.18 / 445.16 | 5 | 34 |
6 | 13 | 118.48 | 20 | 14.99 | 524 | 157 | 4.33 / 445.32 | 5 | 27 |
7 | 13 | 29.88 | 20 | 15.01 | 396 | 119 | 4.45 / 445.44 | 6 | 28 |
8 | 8 | 0.04 | 261 | 14.95 | 339 | 1323 | 5.78 / 446.76 | 6 | 130 |
Average= | 7.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.48 | 37 | 14.96 | 454 | 251 | 0.25 / 435.28 | 6 | 7 |
2 | 7 | 2004.76 | 40 | 14.62 | 3041 | 1778 | 2.03 / 437.06 | 7 | 23 |
3 | 13 | 1915.72 | 20 | 14.59 | 2927 | 854 | 2.88 / 437.91 | 5 | 25 |
4 | 13 | 1727.60 | 20 | 14.54 | 2700 | 785 | 3.67 / 438.70 | 5 | 29 |
5 | 13 | 1157.24 | 20 | 14.64 | 1954 | 572 | 4.24 / 439.27 | 5 | 34 |
6 | 13 | 353.60 | 20 | 14.90 | 868 | 259 | 4.50 / 439.53 | 5 | 35 |
7 | 13 | 60.08 | 20 | 14.99 | 441 | 132 | 4.63 / 439.66 | 5 | 32 |
8 | 8 | -0.04 | 263 | 14.95 | 336 | 1321 | 5.95 / 440.98 | 6 | 141 |
Average= | 7.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.40 | 37 | 14.97 | 469 | 260 | 0.26 / 429.33 | 6 | 7 |
2 | 7 | 2016.88 | 41 | 14.61 | 3052 | 1828 | 2.09 / 431.16 | 19 | 23 |
3 | 13 | 1925.56 | 20 | 14.58 | 2949 | 860 | 2.95 / 432.02 | 5 | 25 |
4 | 13 | 1496.52 | 20 | 14.59 | 2390 | 697 | 3.65 / 432.72 | 5 | 31 |
5 | 13 | 960.16 | 20 | 14.69 | 1692 | 497 | 4.14 / 433.22 | 5 | 35 |
6 | 13 | 623.00 | 20 | 14.78 | 1242 | 367 | 4.51 / 433.58 | 5 | 37 |
7 | 13 | 60.88 | 20 | 14.99 | 435 | 130 | 4.64 / 433.71 | 5 | 29 |
8 | 8 | 0.08 | 265 | 14.94 | 333 | 1318 | 5.96 / 435.03 | 6 | 139 |
Average= | 7.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.80 | 37 | 14.95 | 468 | 259 | 0.26 / 423.21 | 6 | 7 |
2 | 7 | 2006.20 | 40 | 14.62 | 3038 | 1777 | 2.04 / 424.99 | 7 | 24 |
3 | 13 | 1919.48 | 20 | 14.59 | 2949 | 861 | 2.90 / 425.85 | 5 | 27 |
4 | 13 | 1591.60 | 20 | 14.57 | 2531 | 738 | 3.63 / 426.59 | 5 | 33 |
5 | 13 | 1496.56 | 20 | 14.53 | 2395 | 696 | 4.33 / 427.28 | 5 | 33 |
6 | 13 | 528.68 | 20 | 14.82 | 1121 | 332 | 4.66 / 427.61 | 5 | 34 |
7 | 8 | 0.08 | 285 | 14.96 | 342 | 1458 | 6.12 / 429.07 | 6 | 137 |
Average= | 7.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.44 | 37 | 14.96 | 444 | 246 | 0.25 / 417.42 | 6 | 6 |
2 | 7 | 2016.96 | 40 | 14.61 | 3059 | 1788 | 2.03 / 419.21 | 6 | 25 |
3 | 13 | 1945.84 | 20 | 14.57 | 2977 | 867 | 2.90 / 420.08 | 5 | 23 |
4 | 13 | 1524.60 | 20 | 14.58 | 2438 | 711 | 3.61 / 420.79 | 5 | 32 |
5 | 13 | 985.72 | 20 | 14.68 | 1733 | 509 | 4.12 / 421.30 | 5 | 36 |
6 | 13 | 294.72 | 20 | 14.91 | 779 | 232 | 4.35 / 421.53 | 5 | 33 |
7 | 13 | 37.44 | 20 | 15.00 | 406 | 122 | 4.47 / 421.65 | 5 | 19 |
8 | 8 | 0.00 | 261 | 14.95 | 333 | 1299 | 5.77 / 422.95 | 6 | 136 |
Average= | 7.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.48 | 37 | 14.95 | 462 | 256 | 0.26 / 411.73 | 6 | 6 |
2 | 7 | 2013.04 | 40 | 14.61 | 3053 | 1784 | 2.04 / 413.51 | 6 | 20 |
3 | 13 | 1922.68 | 20 | 14.58 | 2951 | 861 | 2.90 / 414.37 | 5 | 29 |
4 | 13 | 1396.48 | 20 | 14.61 | 2269 | 663 | 3.56 / 415.04 | 5 | 34 |
5 | 13 | 1060.44 | 20 | 14.66 | 1831 | 537 | 4.10 / 415.57 | 5 | 35 |
6 | 13 | 263.60 | 20 | 14.92 | 730 | 218 | 4.32 / 415.79 | 5 | 27 |
7 | 8 | -0.04 | 282 | 14.95 | 329 | 1387 | 5.70 / 417.18 | 6 | 140 |
Average= | 7.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.32 | 37 | 14.97 | 434 | 240 | 0.24 / 405.77 | 6 | 7 |
2 | 7 | 2018.32 | 40 | 14.62 | 3052 | 1785 | 2.03 / 407.56 | 7 | 21 |
3 | 13 | 1933.68 | 20 | 14.59 | 2947 | 860 | 2.89 / 408.42 | 5 | 26 |
4 | 13 | 1513.64 | 20 | 14.59 | 2423 | 707 | 3.59 / 409.12 | 5 | 30 |
5 | 13 | 1071.60 | 20 | 14.66 | 1837 | 539 | 4.13 / 409.66 | 5 | 35 |
6 | 13 | 608.92 | 20 | 14.79 | 1217 | 360 | 4.49 / 410.02 | 5 | 37 |
7 | 13 | 54.04 | 20 | 14.99 | 430 | 129 | 4.62 / 410.15 | 5 | 33 |
8 | 8 | 0.00 | 261 | 14.94 | 339 | 1322 | 5.94 / 411.47 | 6 | 139 |
Average= | 7.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.00 | 37 | 14.97 | 455 | 252 | 0.25 / 400.02 | 6 | 6 |
2 | 7 | 2016.80 | 40 | 14.62 | 3056 | 1787 | 2.04 / 401.81 | 6 | 23 |
3 | 13 | 1937.32 | 20 | 14.59 | 2950 | 861 | 2.90 / 402.67 | 5 | 27 |
4 | 13 | 1418.88 | 20 | 14.61 | 2299 | 672 | 3.57 / 403.34 | 5 | 32 |
5 | 13 | 1229.48 | 20 | 14.60 | 2053 | 599 | 4.17 / 403.94 | 5 | 34 |
6 | 13 | 290.04 | 20 | 14.92 | 770 | 230 | 4.40 / 404.17 | 5 | 33 |
7 | 8 | 0.08 | 278 | 14.96 | 327 | 1360 | 5.76 / 405.53 | 6 | 132 |
Average= | 7.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.88 | 36 | 14.96 | 475 | 256 | 0.26 / 394.07 | 6 | 6 |
2 | 10 | 1003.92 | 4 | 15.03 | 1718 | 103 | 0.36 / 394.17 | 5 | 18 |
3 | 3 | 901.52 | -2 | 15.39 | 5 | 0 | 0.10 / 394.17 | 5 | 18 |
4 | 7 | 2003.68 | 40 | 14.63 | 3037 | 1777 | 2.14 / 395.95 | 18 | 22 |
5 | 13 | 1908.60 | 20 | 14.61 | 2917 | 852 | 2.99 / 396.80 | 5 | 25 |
6 | 13 | 1698.00 | 20 | 14.56 | 2657 | 774 | 3.76 / 397.57 | 5 | 30 |
7 | 13 | 1018.12 | 20 | 14.69 | 1777 | 522 | 4.28 / 398.10 | 5 | 35 |
8 | 13 | 357.12 | 20 | 14.90 | 868 | 259 | 4.54 / 398.36 | 5 | 35 |
9 | 13 | 55.76 | 20 | 15.00 | 430 | 129 | 4.67 / 398.48 | 5 | 40 |
10 | 8 | 0.00 | 263 | 14.96 | 327 | 1287 | 5.96 / 399.77 | 6 | 146 |
Average= | 7.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.16 | 36 | 14.97 | 450 | 243 | 0.24 / 388.02 | 6 | 6 |
2 | 7 | 2009.44 | 40 | 14.63 | 3041 | 1780 | 2.02 / 389.80 | 6 | 22 |
3 | 13 | 1931.28 | 20 | 14.60 | 2943 | 859 | 2.88 / 390.65 | 5 | 26 |
4 | 13 | 1603.04 | 20 | 14.58 | 2527 | 737 | 3.62 / 391.39 | 5 | 28 |
5 | 13 | 1164.44 | 20 | 14.63 | 1965 | 575 | 4.19 / 391.97 | 5 | 35 |
6 | 13 | 675.20 | 20 | 14.77 | 1306 | 386 | 4.58 / 392.35 | 5 | 36 |
7 | 13 | 43.16 | 20 | 15.00 | 411 | 123 | 4.70 / 392.48 | 6 | 42 |
8 | 8 | -0.08 | 263 | 14.95 | 340 | 1337 | 6.04 / 393.81 | 6 | 131 |
Average= | 7.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.12 | 36 | 14.96 | 466 | 251 | 0.25 / 382.44 | 6 | 6 |
2 | 7 | 2013.88 | 40 | 14.63 | 3048 | 1784 | 2.03 / 384.23 | 6 | 22 |
3 | 13 | 1918.96 | 20 | 14.59 | 2940 | 858 | 2.89 / 385.08 | 5 | 27 |
4 | 13 | 1393.12 | 20 | 14.62 | 2272 | 664 | 3.56 / 385.75 | 5 | 33 |
5 | 13 | 977.44 | 20 | 14.69 | 1719 | 505 | 4.06 / 386.25 | 5 | 34 |
6 | 13 | 111.12 | 20 | 15.00 | 507 | 152 | 4.21 / 386.41 | 5 | 27 |
7 | 8 | 0.08 | 276 | 14.97 | 331 | 1368 | 5.58 / 387.77 | 6 | 136 |
Average= | 7.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.72 | 36 | 14.98 | 437 | 236 | 0.24 / 376.68 | 6 | 6 |
2 | 7 | 2012.08 | 40 | 14.63 | 3043 | 1781 | 2.02 / 378.46 | 6 | 22 |
3 | 13 | 1821.64 | 20 | 14.61 | 2817 | 823 | 2.84 / 379.28 | 5 | 26 |
4 | 13 | 1613.40 | 20 | 14.57 | 2557 | 745 | 3.58 / 380.03 | 5 | 31 |
5 | 13 | 934.56 | 20 | 14.71 | 1669 | 491 | 4.08 / 380.52 | 5 | 35 |
6 | 13 | 264.44 | 20 | 14.93 | 747 | 223 | 4.30 / 380.74 | 5 | 32 |
7 | 13 | 37.08 | 20 | 15.01 | 404 | 121 | 4.42 / 380.86 | 5 | 21 |
8 | 8 | 0.00 | 259 | 14.95 | 343 | 1328 | 5.75 / 382.19 | 6 | 136 |
Average= | 7.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.32 | 36 | 14.98 | 448 | 242 | 0.24 / 371.09 | 6 | 6 |
2 | 7 | 2006.84 | 40 | 14.63 | 3040 | 1779 | 2.02 / 372.87 | 6 | 22 |
3 | 13 | 1924.08 | 20 | 14.61 | 2939 | 859 | 2.88 / 373.73 | 5 | 25 |
4 | 13 | 1391.80 | 20 | 14.62 | 2270 | 664 | 3.54 / 374.39 | 5 | 31 |
5 | 13 | 965.48 | 20 | 14.69 | 1710 | 502 | 4.05 / 374.89 | 5 | 35 |
6 | 13 | 108.92 | 20 | 15.00 | 510 | 153 | 4.20 / 375.05 | 5 | 27 |
7 | 13 | 36.60 | 20 | 15.01 | 399 | 120 | 4.32 / 375.17 | 6 | 27 |
8 | 8 | 0.20 | 255 | 14.96 | 335 | 1278 | 5.60 / 376.44 | 6 | 131 |
Average= | 7.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.16 | 36 | 14.97 | 451 | 243 | 0.24 / 365.35 | 6 | 8 |
2 | 7 | 2005.88 | 40 | 14.64 | 3039 | 1780 | 2.02 / 367.13 | 8 | 25 |
3 | 13 | 1921.00 | 20 | 14.61 | 2940 | 859 | 2.88 / 367.99 | 5 | 25 |
4 | 13 | 1601.60 | 20 | 14.58 | 2546 | 742 | 3.62 / 368.73 | 5 | 32 |
5 | 13 | 1041.84 | 20 | 14.68 | 1809 | 531 | 4.16 / 369.27 | 5 | 34 |
6 | 13 | 160.20 | 20 | 14.98 | 581 | 174 | 4.33 / 369.44 | 5 | 25 |
7 | 13 | 36.84 | 20 | 15.02 | 402 | 121 | 4.45 / 369.56 | 5 | 27 |
8 | 8 | 0.08 | 259 | 14.97 | 332 | 1287 | 5.74 / 370.85 | 6 | 136 |
Average= | 7.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.24 | 36 | 14.99 | 460 | 248 | 0.25 / 359.66 | 6 | 9 |
2 | 7 | 2007.56 | 40 | 14.64 | 3043 | 1782 | 2.03 / 361.44 | 9 | 20 |
3 | 13 | 1920.72 | 20 | 14.61 | 2942 | 860 | 2.89 / 362.30 | 5 | 27 |
4 | 13 | 1405.28 | 20 | 14.62 | 2293 | 670 | 3.56 / 362.97 | 5 | 30 |
5 | 13 | 981.84 | 20 | 14.70 | 1726 | 507 | 4.07 / 363.48 | 5 | 35 |
6 | 13 | 201.72 | 20 | 14.96 | 648 | 194 | 4.26 / 363.67 | 5 | 32 |
7 | 13 | 40.04 | 20 | 15.01 | 413 | 124 | 4.39 / 363.79 | 5 | 25 |
8 | 8 | 0.04 | 261 | 14.96 | 337 | 1316 | 5.70 / 365.11 | 6 | 135 |
Average= | 7.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.40 | 36 | 14.99 | 450 | 243 | 0.24 / 354.00 | 6 | 6 |
2 | 7 | 2012.60 | 40 | 14.64 | 3053 | 1788 | 2.03 / 355.79 | 6 | 23 |
3 | 13 | 1922.20 | 20 | 14.60 | 2948 | 861 | 2.89 / 356.65 | 5 | 25 |
4 | 13 | 1607.64 | 20 | 14.58 | 2552 | 744 | 3.64 / 357.40 | 5 | 31 |
5 | 13 | 861.32 | 20 | 14.74 | 1572 | 463 | 4.10 / 357.86 | 5 | 35 |
6 | 13 | 103.72 | 20 | 15.01 | 502 | 151 | 4.25 / 358.01 | 5 | 29 |
7 | 13 | 27.20 | 20 | 15.03 | 392 | 118 | 4.37 / 358.13 | 6 | 26 |
8 | 8 | 0.08 | 255 | 14.97 | 335 | 1279 | 5.65 / 359.41 | 6 | 149 |
Average= | 7.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.80 | 36 | 14.98 | 451 | 243 | 0.24 / 348.34 | 6 | 8 |
2 | 7 | 2014.28 | 40 | 14.63 | 3051 | 1785 | 2.03 / 350.13 | 8 | 20 |
3 | 13 | 1919.68 | 20 | 14.61 | 2950 | 862 | 2.89 / 350.99 | 5 | 28 |
4 | 13 | 1588.24 | 20 | 14.59 | 2531 | 739 | 3.63 / 351.73 | 5 | 30 |
5 | 13 | 813.40 | 20 | 14.76 | 1519 | 448 | 4.08 / 352.18 | 5 | 35 |
6 | 13 | 97.88 | 20 | 15.01 | 502 | 151 | 4.23 / 352.33 | 5 | 27 |
7 | 13 | 27.32 | 20 | 15.03 | 395 | 119 | 4.35 / 352.45 | 6 | 13 |
8 | 8 | 0.00 | 255 | 14.97 | 344 | 1313 | 5.66 / 353.76 | 6 | 146 |
Average= | 8.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.12 | 36 | 14.97 | 477 | 257 | 0.26 / 342.70 | 6 | 8 |
2 | 7 | 2014.40 | 40 | 14.63 | 3053 | 1787 | 2.04 / 344.49 | 8 | 20 |
3 | 13 | 1929.44 | 20 | 14.60 | 2960 | 864 | 2.91 / 345.35 | 5 | 24 |
4 | 13 | 1322.20 | 20 | 14.65 | 2182 | 639 | 3.55 / 345.99 | 5 | 32 |
5 | 13 | 799.72 | 20 | 14.76 | 1486 | 439 | 3.99 / 346.43 | 5 | 36 |
6 | 13 | 368.20 | 20 | 14.90 | 885 | 264 | 4.25 / 346.70 | 5 | 36 |
7 | 13 | 27.00 | 20 | 15.02 | 390 | 117 | 4.37 / 346.81 | 6 | 33 |
8 | 8 | 0.04 | 257 | 14.97 | 335 | 1289 | 5.66 / 348.10 | 6 | 130 |
Average= | 8.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.20 | 36 | 14.99 | 451 | 243 | 0.24 / 336.95 | 6 | 6 |
2 | 7 | 2005.68 | 40 | 14.65 | 3045 | 1784 | 2.03 / 338.73 | 6 | 25 |
3 | 13 | 1916.48 | 20 | 14.61 | 2945 | 861 | 2.89 / 339.59 | 5 | 25 |
4 | 13 | 1488.72 | 20 | 14.62 | 2392 | 699 | 3.59 / 340.29 | 5 | 30 |
5 | 13 | 864.32 | 20 | 14.75 | 1569 | 463 | 4.05 / 340.75 | 5 | 35 |
6 | 13 | 300.68 | 20 | 14.94 | 788 | 235 | 4.29 / 340.99 | 5 | 34 |
7 | 13 | 16.24 | 20 | 15.03 | 378 | 114 | 4.40 / 341.10 | 5 | 29 |
8 | 8 | -0.08 | 263 | 14.97 | 341 | 1343 | 5.74 / 342.45 | 6 | 135 |
Average= | 8.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.16 | 36 | 15.01 | 462 | 250 | 0.25 / 331.26 | 6 | 6 |
2 | 7 | 2006.04 | 40 | 14.64 | 3044 | 1783 | 2.03 / 333.05 | 6 | 21 |
3 | 13 | 1917.16 | 20 | 14.62 | 2933 | 858 | 2.89 / 333.90 | 5 | 25 |
4 | 13 | 1398.52 | 20 | 14.64 | 2278 | 667 | 3.56 / 334.57 | 5 | 31 |
5 | 13 | 968.04 | 20 | 14.72 | 1712 | 504 | 4.06 / 335.08 | 5 | 36 |
6 | 13 | 290.52 | 20 | 14.94 | 779 | 233 | 4.29 / 335.31 | 5 | 33 |
7 | 13 | 17.92 | 20 | 15.04 | 360 | 108 | 4.40 / 335.42 | 6 | 26 |
8 | 8 | 0.08 | 255 | 14.98 | 337 | 1287 | 5.69 / 336.70 | 6 | 132 |
Average= | 8.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.68 | 36 | 15.00 | 445 | 240 | 0.24 / 325.66 | 6 | 8 |
2 | 7 | 2010.48 | 40 | 14.65 | 3044 | 1784 | 2.02 / 327.45 | 8 | 21 |
3 | 13 | 1921.92 | 20 | 14.63 | 2930 | 857 | 2.88 / 328.30 | 5 | 26 |
4 | 13 | 1412.88 | 20 | 14.64 | 2295 | 672 | 3.55 / 328.98 | 5 | 32 |
5 | 13 | 874.36 | 20 | 14.76 | 1590 | 469 | 4.02 / 329.45 | 5 | 36 |
6 | 13 | 134.88 | 20 | 15.02 | 559 | 168 | 4.19 / 329.61 | 5 | 28 |
7 | 13 | 16.56 | 20 | 15.05 | 377 | 113 | 4.30 / 329.73 | 6 | 33 |
8 | 8 | 0.08 | 255 | 14.99 | 337 | 1288 | 5.59 / 331.01 | 6 | 135 |
Average= | 8.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.16 | 36 | 15.00 | 454 | 245 | 0.25 / 320.01 | 6 | 8 |
2 | 7 | 2005.52 | 40 | 14.65 | 3036 | 1779 | 2.02 / 321.79 | 8 | 22 |
3 | 13 | 1912.88 | 20 | 14.63 | 2929 | 857 | 2.88 / 322.65 | 5 | 27 |
4 | 13 | 1588.28 | 20 | 14.61 | 2517 | 735 | 3.62 / 323.38 | 5 | 30 |
5 | 13 | 915.28 | 20 | 14.75 | 1632 | 481 | 4.10 / 323.87 | 5 | 36 |
6 | 13 | 149.52 | 20 | 15.02 | 566 | 170 | 4.27 / 324.04 | 5 | 32 |
7 | 13 | 40.76 | 20 | 15.05 | 407 | 123 | 4.39 / 324.16 | 5 | 21 |
8 | 8 | 0.12 | 257 | 15.00 | 328 | 1264 | 5.66 / 325.42 | 6 | 136 |
Average= | 8.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.40 | 36 | 15.01 | 457 | 247 | 0.25 / 314.42 | 6 | 6 |
2 | 7 | 2005.32 | 40 | 14.65 | 3048 | 1786 | 2.03 / 316.20 | 6 | 22 |
3 | 13 | 1918.52 | 20 | 14.62 | 2937 | 859 | 2.89 / 317.06 | 5 | 25 |
4 | 13 | 1390.24 | 20 | 14.66 | 2261 | 663 | 3.55 / 317.73 | 5 | 31 |
5 | 13 | 847.68 | 20 | 14.78 | 1548 | 458 | 4.01 / 318.18 | 5 | 35 |
6 | 13 | 95.40 | 20 | 15.04 | 492 | 148 | 4.16 / 318.33 | 5 | 25 |
7 | 13 | 51.36 | 20 | 15.05 | 426 | 128 | 4.29 / 318.46 | 6 | 31 |
8 | 8 | 0.00 | 257 | 15.00 | 339 | 1307 | 5.60 / 319.77 | 6 | 139 |
Average= | 8.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.80 | 36 | 15.02 | 468 | 253 | 0.25 / 308.47 | 6 | 6 |
2 | 3 | 1020.84 | 1 | 15.11 | 1781 | 27 | 0.28 / 308.50 | 5 | 10 |
3 | 7 | 2014.88 | 40 | 14.66 | 3053 | 1790 | 2.07 / 310.29 | 10 | 22 |
4 | 13 | 1927.96 | 20 | 14.63 | 2955 | 865 | 2.93 / 311.15 | 5 | 26 |
5 | 13 | 1724.64 | 20 | 14.59 | 2692 | 786 | 3.72 / 311.94 | 5 | 28 |
6 | 13 | 1028.36 | 20 | 14.73 | 1791 | 528 | 4.25 / 312.46 | 5 | 35 |
7 | 13 | 451.88 | 20 | 14.91 | 1002 | 299 | 4.55 / 312.76 | 5 | 37 |
8 | 13 | 18.64 | 20 | 15.06 | 369 | 111 | 4.66 / 312.87 | 6 | 30 |
9 | 8 | -0.04 | 259 | 15.00 | 334 | 1298 | 5.96 / 314.17 | 6 | 143 |
Average= | 8.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.20 | 36 | 15.03 | 446 | 241 | 0.24 / 302.77 | 6 | 6 |
2 | 7 | 2015.08 | 41 | 14.66 | 3045 | 1830 | 2.07 / 304.60 | 6 | 21 |
3 | 13 | 1921.96 | 20 | 14.62 | 2936 | 858 | 2.93 / 305.46 | 5 | 25 |
4 | 13 | 1390.92 | 20 | 14.66 | 2259 | 662 | 3.59 / 306.12 | 5 | 31 |
5 | 13 | 749.52 | 20 | 14.82 | 1422 | 421 | 4.01 / 306.54 | 5 | 36 |
6 | 13 | 318.08 | 20 | 14.96 | 811 | 243 | 4.26 / 306.79 | 5 | 34 |
7 | 13 | 36.68 | 20 | 15.06 | 396 | 119 | 4.38 / 306.90 | 5 | 31 |
8 | 8 | 0.00 | 264 | 15.01 | 331 | 1312 | 5.69 / 308.22 | 6 | 141 |
Average= | 8.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.44 | 36 | 15.03 | 449 | 243 | 0.24 / 297.09 | 6 | 6 |
2 | 7 | 2007.28 | 40 | 14.67 | 3040 | 1784 | 2.03 / 298.88 | 6 | 22 |
3 | 13 | 1920.28 | 20 | 14.64 | 2933 | 859 | 2.89 / 299.74 | 5 | 25 |
4 | 13 | 1607.64 | 20 | 14.62 | 2536 | 742 | 3.63 / 300.48 | 5 | 30 |
5 | 13 | 853.28 | 20 | 14.80 | 1544 | 457 | 4.08 / 300.93 | 5 | 35 |
6 | 13 | 185.80 | 20 | 15.03 | 618 | 186 | 4.27 / 301.12 | 5 | 32 |
7 | 13 | 17.56 | 20 | 15.08 | 367 | 111 | 4.38 / 301.23 | 6 | 28 |
8 | 8 | 0.00 | 265 | 15.02 | 326 | 1298 | 5.68 / 302.53 | 6 | 137 |
Average= | 8.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.28 | 36 | 15.03 | 440 | 238 | 0.24 / 291.52 | 6 | 6 |
2 | 7 | 2004.68 | 41 | 14.68 | 3015 | 1815 | 2.05 / 293.33 | 6 | 22 |
3 | 13 | 1916.40 | 20 | 14.64 | 2925 | 856 | 2.91 / 294.19 | 5 | 26 |
4 | 13 | 1382.20 | 20 | 14.68 | 2237 | 657 | 3.57 / 294.84 | 5 | 32 |
5 | 13 | 862.88 | 20 | 14.80 | 1545 | 457 | 4.02 / 295.30 | 5 | 36 |
6 | 13 | 196.88 | 20 | 15.03 | 618 | 186 | 4.21 / 295.49 | 5 | 32 |
7 | 8 | 0.08 | 287 | 15.03 | 316 | 1363 | 5.57 / 296.85 | 6 | 135 |
Average= | 8.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.60 | 36 | 15.05 | 438 | 237 | 0.24 / 285.76 | 6 | 6 |
2 | 7 | 2005.72 | 40 | 14.68 | 3025 | 1776 | 2.01 / 287.54 | 6 | 22 |
3 | 13 | 1919.44 | 20 | 14.65 | 2927 | 858 | 2.87 / 288.40 | 5 | 25 |
4 | 13 | 1504.24 | 20 | 14.66 | 2393 | 702 | 3.57 / 289.10 | 5 | 30 |
5 | 13 | 956.52 | 20 | 14.78 | 1671 | 494 | 4.07 / 289.59 | 5 | 35 |
6 | 13 | 497.80 | 20 | 14.91 | 1051 | 313 | 4.38 / 289.91 | 5 | 37 |
7 | 13 | 20.72 | 20 | 15.08 | 359 | 108 | 4.49 / 290.01 | 6 | 27 |
8 | 8 | 0.04 | 274 | 15.03 | 307 | 1264 | 5.75 / 291.28 | 6 | 134 |
Average= | 8.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.68 | 36 | 15.04 | 456 | 247 | 0.25 / 280.23 | 6 | 6 |
2 | 7 | 2004.32 | 40 | 14.68 | 3024 | 1776 | 2.02 / 282.01 | 6 | 22 |
3 | 13 | 1923.04 | 20 | 14.65 | 2930 | 858 | 2.88 / 282.87 | 5 | 25 |
4 | 13 | 1300.28 | 20 | 14.72 | 2136 | 629 | 3.51 / 283.50 | 5 | 32 |
5 | 13 | 974.44 | 20 | 14.77 | 1704 | 503 | 4.01 / 284.00 | 5 | 35 |
6 | 13 | 204.32 | 20 | 15.04 | 633 | 190 | 4.20 / 284.19 | 5 | 32 |
7 | 8 | 0.08 | 291 | 15.05 | 305 | 1336 | 5.54 / 285.53 | 6 | 134 |
Average= | 8.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.64 | 36 | 15.05 | 449 | 243 | 0.24 / 274.52 | 6 | 6 |
2 | 7 | 2007.76 | 40 | 14.68 | 3026 | 1777 | 2.02 / 276.30 | 6 | 22 |
3 | 13 | 1819.92 | 20 | 14.66 | 2808 | 823 | 2.84 / 277.12 | 5 | 26 |
4 | 13 | 1724.60 | 20 | 14.62 | 2682 | 784 | 3.63 / 277.91 | 5 | 29 |
5 | 13 | 754.80 | 20 | 14.87 | 1401 | 417 | 4.04 / 278.32 | 5 | 35 |
6 | 13 | 421.16 | 20 | 14.96 | 950 | 284 | 4.33 / 278.61 | 5 | 36 |
7 | 8 | 0.04 | 293 | 15.05 | 313 | 1380 | 5.71 / 279.99 | 6 | 134 |
Average= | 9.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.76 | 36 | 15.04 | 440 | 238 | 0.24 / 268.94 | 6 | 6 |
2 | 7 | 2010.84 | 40 | 14.68 | 3040 | 1785 | 2.02 / 270.73 | 6 | 22 |
3 | 13 | 1933.76 | 20 | 14.65 | 2941 | 862 | 2.89 / 271.59 | 5 | 25 |
4 | 13 | 1515.60 | 20 | 14.67 | 2419 | 710 | 3.59 / 272.30 | 5 | 31 |
5 | 13 | 953.28 | 20 | 14.79 | 1674 | 495 | 4.09 / 272.79 | 5 | 35 |
6 | 13 | 100.08 | 20 | 15.09 | 475 | 143 | 4.23 / 272.94 | 5 | 27 |
7 | 8 | 0.04 | 287 | 15.06 | 310 | 1340 | 5.57 / 274.28 | 6 | 133 |
Average= | 9.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.12 | 36 | 15.06 | 445 | 241 | 0.24 / 263.35 | 6 | 6 |
2 | 7 | 2006.36 | 40 | 14.69 | 3028 | 1779 | 2.02 / 265.13 | 6 | 22 |
3 | 13 | 1815.56 | 20 | 14.67 | 2796 | 820 | 2.84 / 265.95 | 5 | 26 |
4 | 13 | 1513.64 | 20 | 14.67 | 2410 | 707 | 3.55 / 266.66 | 5 | 30 |
5 | 13 | 855.08 | 20 | 14.83 | 1540 | 457 | 4.00 / 267.12 | 5 | 35 |
6 | 13 | 310.52 | 20 | 15.02 | 788 | 237 | 4.24 / 267.36 | 5 | 34 |
7 | 8 | 0.24 | 289 | 15.06 | 310 | 1349 | 5.59 / 268.70 | 6 | 133 |
Average= | 9.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.56 | 36 | 15.06 | 470 | 255 | 0.25 / 257.85 | 6 | 6 |
2 | 7 | 2005.64 | 40 | 14.69 | 3035 | 1783 | 2.04 / 259.63 | 6 | 22 |
3 | 13 | 1910.88 | 20 | 14.67 | 2921 | 857 | 2.90 / 260.49 | 5 | 25 |
4 | 13 | 1587.36 | 20 | 14.66 | 2506 | 735 | 3.63 / 261.23 | 5 | 30 |
5 | 13 | 758.96 | 20 | 14.88 | 1410 | 420 | 4.05 / 261.65 | 5 | 35 |
6 | 13 | 107.16 | 20 | 15.10 | 492 | 149 | 4.20 / 261.79 | 5 | 28 |
7 | 8 | 0.08 | 285 | 15.08 | 307 | 1319 | 5.52 / 263.11 | 6 | 131 |
Average= | 9.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.36 | 36 | 15.07 | 440 | 239 | 0.24 / 252.27 | 6 | 6 |
2 | 7 | 2009.76 | 40 | 14.69 | 3044 | 1789 | 2.03 / 254.06 | 6 | 22 |
3 | 13 | 1930.64 | 20 | 14.66 | 2940 | 862 | 2.89 / 254.92 | 5 | 25 |
4 | 13 | 1509.76 | 20 | 14.68 | 2398 | 704 | 3.59 / 255.63 | 5 | 30 |
5 | 13 | 864.44 | 20 | 14.85 | 1549 | 460 | 4.05 / 256.09 | 5 | 35 |
6 | 13 | 100.64 | 20 | 15.11 | 482 | 146 | 4.20 / 256.23 | 5 | 28 |
7 | 13 | 13.16 | 20 | 15.13 | 350 | 106 | 4.31 / 256.34 | 6 | 24 |
8 | 8 | 0.04 | 265 | 15.07 | 315 | 1258 | 5.56 / 257.60 | 6 | 140 |
Average= | 9.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.84 | 36 | 15.08 | 442 | 240 | 0.24 / 246.70 | 6 | 6 |
2 | 7 | 2006.52 | 41 | 14.69 | 3032 | 1826 | 2.07 / 248.53 | 6 | 20 |
3 | 13 | 1919.00 | 20 | 14.67 | 2930 | 860 | 2.93 / 249.39 | 5 | 23 |
4 | 13 | 1495.36 | 20 | 14.70 | 2388 | 702 | 3.63 / 250.09 | 5 | 29 |
5 | 13 | 828.96 | 20 | 14.87 | 1503 | 447 | 4.07 / 250.53 | 5 | 34 |
6 | 13 | 163.28 | 20 | 15.09 | 573 | 173 | 4.25 / 250.71 | 5 | 28 |
7 | 13 | 18.20 | 20 | 15.13 | 357 | 108 | 4.36 / 250.82 | 6 | 24 |
8 | 8 | 0.04 | 263 | 15.08 | 307 | 1218 | 5.57 / 252.03 | 6 | 133 |
Average= | 9.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.04 | 36 | 15.08 | 452 | 245 | 0.25 / 241.23 | 6 | 6 |
2 | 7 | 2005.76 | 40 | 14.70 | 3032 | 1783 | 2.03 / 243.01 | 6 | 20 |
3 | 13 | 1921.04 | 20 | 14.68 | 2927 | 859 | 2.89 / 243.87 | 5 | 24 |
4 | 13 | 1496.92 | 20 | 14.70 | 2401 | 706 | 3.59 / 244.58 | 5 | 29 |
5 | 13 | 764.56 | 20 | 14.90 | 1417 | 422 | 4.02 / 245.00 | 5 | 34 |
6 | 13 | 112.76 | 20 | 15.11 | 498 | 150 | 4.17 / 245.15 | 5 | 26 |
7 | 8 | 0.08 | 285 | 15.09 | 305 | 1312 | 5.48 / 246.46 | 6 | 130 |
Average= | 9.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.32 | 36 | 15.08 | 456 | 248 | 0.25 / 235.48 | 6 | 6 |
2 | 7 | 2017.40 | 40 | 14.70 | 3043 | 1789 | 2.04 / 237.27 | 6 | 21 |
3 | 13 | 1928.76 | 20 | 14.67 | 2948 | 865 | 2.90 / 238.14 | 5 | 24 |
4 | 13 | 1617.56 | 20 | 14.67 | 2552 | 749 | 3.65 / 238.89 | 5 | 28 |
5 | 13 | 1053.12 | 20 | 14.80 | 1811 | 536 | 4.19 / 239.42 | 5 | 34 |
6 | 13 | 153.12 | 20 | 15.10 | 566 | 171 | 4.36 / 239.59 | 5 | 28 |
7 | 13 | 27.56 | 20 | 15.14 | 371 | 112 | 4.47 / 239.71 | 5 | 26 |
8 | 8 | -0.08 | 270 | 15.09 | 313 | 1275 | 5.75 / 240.98 | 6 | 137 |
Average= | 10.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.60 | 36 | 15.10 | 453 | 246 | 0.25 / 229.88 | 6 | 6 |
2 | 7 | 2008.80 | 40 | 14.70 | 3027 | 1780 | 2.03 / 231.66 | 6 | 21 |
3 | 13 | 1823.52 | 20 | 14.69 | 2811 | 826 | 2.85 / 232.48 | 5 | 25 |
4 | 13 | 1423.72 | 20 | 14.73 | 2292 | 675 | 3.53 / 233.16 | 5 | 30 |
5 | 13 | 889.12 | 20 | 14.86 | 1593 | 473 | 4.00 / 233.63 | 5 | 34 |
6 | 13 | 310.52 | 20 | 15.05 | 788 | 237 | 4.24 / 233.87 | 5 | 32 |
7 | 8 | 0.04 | 289 | 15.09 | 314 | 1369 | 5.61 / 235.24 | 6 | 136 |
Average= | 10.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.72 | 35 | 15.09 | 453 | 239 | 0.24 / 224.44 | 6 | 6 |
2 | 7 | 2011.36 | 40 | 14.71 | 3033 | 1785 | 2.02 / 226.22 | 6 | 21 |
3 | 13 | 1921.64 | 20 | 14.69 | 2931 | 861 | 2.88 / 227.08 | 5 | 24 |
4 | 13 | 1408.68 | 20 | 14.74 | 2273 | 670 | 3.56 / 227.75 | 5 | 30 |
5 | 13 | 742.08 | 20 | 14.92 | 1391 | 415 | 3.97 / 228.17 | 5 | 35 |
6 | 13 | 74.12 | 20 | 15.15 | 442 | 134 | 4.10 / 228.30 | 5 | 24 |
7 | 13 | 20.20 | 20 | 15.15 | 365 | 111 | 4.21 / 228.41 | 6 | 23 |
8 | 8 | 0.04 | 259 | 15.11 | 311 | 1217 | 5.43 / 229.63 | 6 | 134 |
Average= | 10.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.92 | 35 | 15.10 | 456 | 241 | 0.24 / 218.80 | 6 | 6 |
2 | 7 | 2007.24 | 40 | 14.71 | 3039 | 1788 | 2.03 / 220.59 | 6 | 22 |
3 | 13 | 1926.40 | 20 | 14.68 | 2947 | 865 | 2.89 / 221.45 | 5 | 24 |
4 | 13 | 1493.40 | 20 | 14.72 | 2400 | 707 | 3.60 / 222.16 | 5 | 30 |
5 | 13 | 945.76 | 20 | 14.86 | 1665 | 495 | 4.10 / 222.66 | 5 | 34 |
6 | 13 | 170.88 | 20 | 15.11 | 583 | 176 | 4.27 / 222.83 | 5 | 29 |
7 | 8 | 0.08 | 285 | 15.11 | 317 | 1365 | 5.64 / 224.20 | 6 | 132 |
Average= | 10.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.40 | 35 | 15.11 | 458 | 242 | 0.24 / 213.07 | 6 | 6 |
2 | 3 | 1020.88 | 1 | 15.16 | 1771 | 27 | 0.27 / 213.09 | 5 | 5 |
3 | 7 | 2006.12 | 41 | 14.70 | 3033 | 1828 | 2.10 / 214.92 | 5 | 21 |
4 | 13 | 1912.32 | 20 | 14.69 | 2919 | 858 | 2.95 / 215.78 | 5 | 24 |
5 | 13 | 1280.76 | 20 | 14.79 | 2106 | 623 | 3.58 / 216.40 | 5 | 31 |
6 | 13 | 855.28 | 20 | 14.89 | 1545 | 460 | 4.04 / 216.86 | 5 | 35 |
7 | 13 | 506.08 | 20 | 14.99 | 1064 | 319 | 4.36 / 217.18 | 5 | 36 |
8 | 8 | 0.08 | 287 | 15.11 | 318 | 1379 | 5.74 / 218.56 | 6 | 129 |
Average= | 10.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.20 | 35 | 15.12 | 459 | 243 | 0.24 / 207.47 | 6 | 6 |
2 | 7 | 2007.00 | 40 | 14.72 | 3027 | 1782 | 2.03 / 209.26 | 6 | 21 |
3 | 13 | 1927.04 | 20 | 14.70 | 2935 | 863 | 2.89 / 210.12 | 5 | 24 |
4 | 13 | 1270.56 | 20 | 14.80 | 2092 | 619 | 3.51 / 210.74 | 5 | 31 |
5 | 13 | 939.56 | 20 | 14.87 | 1662 | 494 | 4.00 / 211.23 | 5 | 35 |
6 | 13 | 251.88 | 20 | 15.09 | 710 | 214 | 4.22 / 211.45 | 5 | 32 |
7 | 13 | 21.16 | 20 | 15.16 | 369 | 112 | 4.33 / 211.56 | 6 | 26 |
8 | 8 | -0.08 | 265 | 15.11 | 316 | 1265 | 5.59 / 212.82 | 6 | 150 |
Average= | 11.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.68 | 35 | 15.11 | 460 | 243 | 0.24 / 201.82 | 6 | 6 |
2 | 7 | 2008.44 | 40 | 14.72 | 3048 | 1795 | 2.04 / 203.62 | 6 | 21 |
3 | 13 | 1924.60 | 20 | 14.70 | 2926 | 860 | 2.90 / 204.48 | 5 | 24 |
4 | 13 | 1614.48 | 20 | 14.71 | 2538 | 747 | 3.64 / 205.22 | 5 | 29 |
5 | 13 | 859.40 | 20 | 14.91 | 1559 | 465 | 4.11 / 205.69 | 5 | 35 |
6 | 13 | 189.40 | 20 | 15.12 | 617 | 187 | 4.30 / 205.87 | 5 | 31 |
7 | 8 | 0.12 | 285 | 15.12 | 315 | 1357 | 5.65 / 207.23 | 6 | 131 |
Average= | 11.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.80 | 36 | 15.12 | 447 | 243 | 0.24 / 195.98 | 6 | 6 |
2 | 7 | 2009.12 | 41 | 14.72 | 3040 | 1835 | 2.08 / 197.82 | 6 | 22 |
3 | 13 | 1916.96 | 20 | 14.70 | 2938 | 864 | 2.94 / 198.68 | 5 | 25 |
4 | 13 | 1372.88 | 20 | 14.78 | 2233 | 660 | 3.60 / 199.34 | 5 | 31 |
5 | 13 | 921.20 | 20 | 14.89 | 1641 | 489 | 4.09 / 199.83 | 5 | 35 |
6 | 13 | 449.60 | 20 | 15.03 | 995 | 299 | 4.39 / 200.13 | 5 | 36 |
7 | 13 | 39.96 | 20 | 15.16 | 411 | 125 | 4.51 / 200.25 | 5 | 29 |
8 | 8 | 0.04 | 265 | 15.11 | 331 | 1325 | 5.84 / 201.58 | 6 | 135 |
Average= | 11.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.36 | 36 | 15.13 | 461 | 251 | 0.25 / 190.19 | 6 | 6 |
2 | 7 | 2011.28 | 40 | 14.72 | 3043 | 1792 | 2.04 / 191.98 | 6 | 22 |
3 | 13 | 1923.40 | 20 | 14.71 | 2942 | 866 | 2.91 / 192.85 | 5 | 25 |
4 | 13 | 1513.00 | 20 | 14.75 | 2419 | 714 | 3.62 / 193.56 | 5 | 30 |
5 | 13 | 852.48 | 20 | 14.92 | 1548 | 462 | 4.08 / 194.02 | 5 | 36 |
6 | 13 | 398.84 | 20 | 15.05 | 926 | 279 | 4.36 / 194.30 | 5 | 35 |
7 | 13 | 31.36 | 20 | 15.17 | 391 | 119 | 4.48 / 194.42 | 5 | 28 |
8 | 8 | -0.12 | 267 | 15.12 | 327 | 1320 | 5.80 / 195.74 | 6 | 130 |
Average= | 12.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.48 | 36 | 15.15 | 450 | 245 | 0.25 / 184.53 | 6 | 6 |
2 | 7 | 2008.12 | 40 | 14.73 | 3039 | 1791 | 2.04 / 186.32 | 6 | 22 |
3 | 13 | 1923.24 | 20 | 14.72 | 2933 | 863 | 2.90 / 187.18 | 5 | 25 |
4 | 13 | 1489.76 | 20 | 14.76 | 2379 | 702 | 3.60 / 187.88 | 5 | 31 |
5 | 13 | 843.92 | 20 | 14.93 | 1532 | 457 | 4.06 / 188.34 | 5 | 36 |
6 | 13 | 186.68 | 20 | 15.14 | 615 | 186 | 4.25 / 188.53 | 5 | 31 |
7 | 13 | 17.48 | 20 | 15.18 | 369 | 112 | 4.36 / 188.64 | 6 | 27 |
8 | 8 | 0.04 | 259 | 15.13 | 331 | 1297 | 5.65 / 189.94 | 6 | 135 |
Average= | 12.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.80 | 35 | 15.14 | 447 | 237 | 0.24 / 178.99 | 6 | 6 |
2 | 7 | 2008.84 | 40 | 14.73 | 3029 | 1785 | 2.02 / 180.77 | 5 | 22 |
3 | 13 | 1909.96 | 20 | 14.72 | 2921 | 860 | 2.88 / 181.63 | 5 | 26 |
4 | 13 | 1297.44 | 20 | 14.83 | 2137 | 634 | 3.52 / 182.27 | 5 | 32 |
5 | 13 | 978.80 | 20 | 14.89 | 1718 | 512 | 4.03 / 182.78 | 5 | 36 |
6 | 13 | 94.92 | 20 | 15.18 | 477 | 145 | 4.17 / 182.92 | 5 | 29 |
7 | 8 | 0.08 | 283 | 15.15 | 317 | 1359 | 5.53 / 184.28 | 6 | 155 |
Average= | 13.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.36 | 35 | 15.15 | 452 | 240 | 0.24 / 173.40 | 6 | 6 |
2 | 7 | 2014.40 | 40 | 14.74 | 3037 | 1791 | 2.03 / 175.19 | 6 | 23 |
3 | 13 | 1921.24 | 20 | 14.73 | 2936 | 865 | 2.90 / 176.06 | 5 | 26 |
4 | 13 | 1397.84 | 20 | 14.80 | 2272 | 673 | 3.57 / 176.73 | 5 | 32 |
5 | 13 | 950.32 | 20 | 14.90 | 1676 | 499 | 4.07 / 177.23 | 5 | 36 |
6 | 13 | 85.44 | 20 | 15.18 | 466 | 141 | 4.21 / 177.37 | 5 | 29 |
7 | 8 | 0.12 | 280 | 15.15 | 325 | 1379 | 5.59 / 178.75 | 6 | 137 |
Average= | 13.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.24 | 35 | 15.14 | 451 | 239 | 0.24 / 167.66 | 6 | 6 |
2 | 7 | 2009.24 | 40 | 14.74 | 3044 | 1795 | 2.03 / 169.46 | 6 | 23 |
3 | 13 | 1928.96 | 20 | 14.73 | 2945 | 868 | 2.90 / 170.32 | 5 | 26 |
4 | 13 | 1406.84 | 20 | 14.80 | 2278 | 674 | 3.58 / 171.00 | 5 | 32 |
5 | 13 | 1061.60 | 20 | 14.87 | 1826 | 543 | 4.12 / 171.54 | 5 | 36 |
6 | 13 | 271.84 | 20 | 15.12 | 737 | 223 | 4.34 / 171.76 | 5 | 35 |
7 | 13 | 31.00 | 20 | 15.19 | 388 | 118 | 4.46 / 171.88 | 6 | 30 |
8 | 8 | 0.04 | 263 | 15.15 | 322 | 1283 | 5.74 / 173.16 | 6 | 134 |
Average= | 14.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.84 | 35 | 15.16 | 444 | 236 | 0.24 / 161.89 | 6 | 6 |
2 | 7 | 2006.76 | 40 | 14.74 | 3037 | 1791 | 2.03 / 163.68 | 6 | 24 |
3 | 13 | 1925.64 | 20 | 14.72 | 2937 | 865 | 2.89 / 164.54 | 5 | 26 |
4 | 13 | 1384.36 | 20 | 14.81 | 2251 | 667 | 3.56 / 165.21 | 5 | 33 |
5 | 13 | 840.92 | 20 | 14.95 | 1537 | 460 | 4.02 / 165.67 | 5 | 37 |
6 | 13 | 487.12 | 20 | 15.04 | 1046 | 315 | 4.33 / 165.99 | 5 | 38 |
7 | 13 | 46.12 | 20 | 15.19 | 410 | 125 | 4.46 / 166.11 | 5 | 31 |
8 | 8 | -0.12 | 265 | 15.14 | 327 | 1312 | 5.77 / 167.42 | 6 | 142 |
Average= | 15.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.20 | 35 | 15.16 | 443 | 235 | 0.24 / 156.40 | 6 | 6 |
2 | 7 | 2003.48 | 40 | 14.75 | 3026 | 1785 | 2.02 / 158.19 | 6 | 23 |
3 | 13 | 1909.44 | 20 | 14.74 | 2907 | 857 | 2.88 / 159.05 | 5 | 26 |
4 | 13 | 1365.40 | 20 | 14.82 | 2223 | 659 | 3.54 / 159.70 | 5 | 33 |
5 | 13 | 713.00 | 20 | 15.00 | 1359 | 408 | 3.94 / 160.11 | 5 | 37 |
6 | 13 | 78.04 | 20 | 15.20 | 455 | 138 | 4.08 / 160.25 | 5 | 30 |
7 | 13 | 43.32 | 20 | 15.20 | 406 | 123 | 4.21 / 160.37 | 5 | 29 |
8 | 8 | 0.00 | 259 | 15.16 | 326 | 1280 | 5.49 / 161.65 | 6 | 142 |
Average= | 16.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.12 | 35 | 15.16 | 450 | 239 | 0.24 / 150.76 | 6 | 6 |
2 | 7 | 2008.64 | 40 | 14.76 | 3042 | 1796 | 2.03 / 152.55 | 6 | 23 |
3 | 13 | 1923.92 | 20 | 14.74 | 2939 | 866 | 2.90 / 153.42 | 5 | 27 |
4 | 13 | 1396.40 | 20 | 14.82 | 2267 | 672 | 3.57 / 154.09 | 5 | 33 |
5 | 13 | 856.92 | 20 | 14.95 | 1562 | 467 | 4.04 / 154.56 | 5 | 37 |
6 | 13 | 194.32 | 20 | 15.16 | 629 | 191 | 4.23 / 154.75 | 5 | 33 |
7 | 13 | 37.00 | 20 | 15.20 | 401 | 122 | 4.35 / 154.87 | 5 | 30 |
8 | 8 | 0.00 | 263 | 15.16 | 325 | 1296 | 5.65 / 156.17 | 6 | 136 |
Average= | 17.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.92 | 35 | 15.17 | 453 | 241 | 0.24 / 145.03 | 6 | 6 |
2 | 7 | 2005.64 | 41 | 14.75 | 3030 | 1832 | 2.07 / 146.86 | 6 | 24 |
3 | 13 | 1917.68 | 20 | 14.74 | 2927 | 863 | 2.94 / 147.73 | 5 | 26 |
4 | 13 | 1479.32 | 20 | 14.80 | 2374 | 703 | 3.64 / 148.43 | 5 | 33 |
5 | 13 | 920.40 | 20 | 14.93 | 1637 | 489 | 4.13 / 148.92 | 5 | 37 |
6 | 13 | 127.48 | 20 | 15.19 | 539 | 164 | 4.29 / 149.08 | 5 | 32 |
7 | 13 | 28.08 | 20 | 15.21 | 390 | 119 | 4.41 / 149.20 | 5 | 30 |
8 | 8 | -0.08 | 261 | 15.16 | 333 | 1318 | 5.73 / 150.52 | 6 | 139 |
Average= | 18.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.84 | 35 | 15.17 | 446 | 237 | 0.24 / 139.39 | 6 | 6 |
2 | 7 | 2005.28 | 40 | 14.76 | 3038 | 1794 | 2.03 / 141.19 | 6 | 24 |
3 | 13 | 1818.20 | 20 | 14.77 | 2829 | 836 | 2.87 / 142.02 | 5 | 28 |
4 | 13 | 1726.68 | 20 | 14.73 | 2691 | 793 | 3.66 / 142.82 | 5 | 30 |
5 | 13 | 822.88 | 20 | 14.97 | 1515 | 454 | 4.11 / 143.27 | 5 | 38 |
6 | 13 | 82.72 | 20 | 15.21 | 472 | 144 | 4.26 / 143.41 | 5 | 29 |
7 | 8 | 0.08 | 278 | 15.17 | 327 | 1379 | 5.64 / 144.79 | 6 | 136 |
Average= | 20.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.24 | 35 | 15.18 | 451 | 240 | 0.24 / 133.68 | 6 | 6 |
2 | 7 | 2013.64 | 40 | 14.76 | 3055 | 1804 | 2.04 / 135.48 | 6 | 23 |
3 | 13 | 1920.32 | 20 | 14.75 | 2934 | 866 | 2.91 / 136.35 | 5 | 27 |
4 | 13 | 1477.92 | 20 | 14.81 | 2376 | 704 | 3.61 / 137.05 | 5 | 32 |
5 | 13 | 1038.56 | 20 | 14.90 | 1806 | 538 | 4.15 / 137.59 | 5 | 37 |
6 | 13 | 122.32 | 20 | 15.20 | 529 | 161 | 4.31 / 137.75 | 5 | 31 |
7 | 8 | 0.20 | 285 | 15.17 | 325 | 1405 | 5.72 / 139.16 | 6 | 145 |
Average= | 23.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.44 | 35 | 15.18 | 466 | 248 | 0.25 / 128.10 | 6 | 6 |
2 | 7 | 2003.68 | 40 | 14.76 | 3038 | 1794 | 2.04 / 129.90 | 6 | 24 |
3 | 13 | 1908.36 | 20 | 14.76 | 2927 | 864 | 2.91 / 130.76 | 5 | 27 |
4 | 13 | 1382.00 | 20 | 14.84 | 2252 | 668 | 3.57 / 131.43 | 5 | 33 |
5 | 13 | 848.76 | 20 | 14.96 | 1552 | 464 | 4.04 / 131.89 | 5 | 38 |
6 | 13 | 89.76 | 20 | 15.21 | 479 | 146 | 4.18 / 132.04 | 5 | 30 |
7 | 13 | 19.92 | 20 | 15.23 | 374 | 114 | 4.30 / 132.15 | 6 | 28 |
8 | 8 | 0.00 | 259 | 15.18 | 327 | 1286 | 5.58 / 133.44 | 6 | 137 |
Average= | 26.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.80 | 35 | 15.18 | 453 | 241 | 0.24 / 122.48 | 6 | 6 |
2 | 7 | 2010.96 | 40 | 14.76 | 3051 | 1801 | 2.04 / 124.28 | 6 | 24 |
3 | 13 | 1919.40 | 20 | 14.76 | 2929 | 865 | 2.91 / 125.15 | 5 | 27 |
4 | 13 | 1503.36 | 20 | 14.81 | 2400 | 711 | 3.62 / 125.86 | 5 | 33 |
5 | 13 | 739.84 | 20 | 15.00 | 1405 | 421 | 4.04 / 126.28 | 5 | 38 |
6 | 13 | 93.36 | 20 | 15.21 | 483 | 147 | 4.19 / 126.43 | 5 | 29 |
7 | 13 | 21.48 | 20 | 15.23 | 382 | 116 | 4.30 / 126.54 | 5 | 28 |
8 | 8 | -0.04 | 257 | 15.18 | 337 | 1315 | 5.62 / 127.86 | 6 | 138 |
Average= | 31.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.56 | 35 | 15.18 | 465 | 247 | 0.25 / 116.70 | 6 | 6 |
2 | 7 | 2013.20 | 40 | 14.77 | 3044 | 1798 | 2.05 / 118.50 | 6 | 24 |
3 | 13 | 1928.32 | 20 | 14.77 | 2948 | 871 | 2.92 / 119.37 | 5 | 27 |
4 | 13 | 1489.56 | 20 | 14.82 | 2383 | 706 | 3.62 / 120.08 | 5 | 33 |
5 | 13 | 800.60 | 20 | 14.99 | 1477 | 443 | 4.07 / 120.52 | 5 | 38 |
6 | 13 | 459.80 | 20 | 15.08 | 1012 | 305 | 4.37 / 120.83 | 5 | 39 |
7 | 8 | 0.04 | 285 | 15.18 | 327 | 1415 | 5.79 / 122.24 | 6 | 137 |
Average= | 40.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.28 | 35 | 15.18 | 460 | 244 | 0.24 / 110.85 | 6 | 6 |
2 | 7 | 2008.00 | 40 | 14.77 | 3055 | 1805 | 2.05 / 112.66 | 6 | 25 |
3 | 13 | 1914.60 | 20 | 14.77 | 2942 | 869 | 2.92 / 113.53 | 5 | 27 |
4 | 13 | 1590.92 | 20 | 14.79 | 2530 | 748 | 3.67 / 114.28 | 5 | 32 |
5 | 13 | 1006.92 | 20 | 14.93 | 1763 | 526 | 4.19 / 114.80 | 5 | 38 |
6 | 13 | 183.32 | 20 | 15.18 | 630 | 191 | 4.38 / 114.99 | 5 | 34 |
7 | 8 | 0.04 | 287 | 15.18 | 335 | 1459 | 5.84 / 116.45 | 6 | 139 |
Average= | 58.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.16 | 35 | 15.18 | 481 | 256 | 0.26 / 105.14 | 6 | 6 |
2 | 7 | 2007.64 | 40 | 14.78 | 3044 | 1800 | 2.06 / 106.94 | 5 | 24 |
3 | 13 | 1912.28 | 20 | 14.78 | 2937 | 868 | 2.92 / 107.80 | 5 | 28 |
4 | 13 | 1471.68 | 20 | 14.83 | 2381 | 706 | 3.63 / 108.51 | 5 | 33 |
5 | 13 | 892.84 | 20 | 14.96 | 1616 | 484 | 4.11 / 108.99 | 5 | 38 |
6 | 13 | 192.88 | 20 | 15.19 | 640 | 194 | 4.31 / 109.19 | 5 | 33 |
7 | 8 | 0.04 | 282 | 15.19 | 332 | 1422 | 5.73 / 110.61 | 6 | 142 |
Average= | 110.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.64 | 35 | 15.19 | 477 | 254 | 0.25 / 99.46 | 6 | 6 |
2 | 7 | 2009.76 | 40 | 14.79 | 3061 | 1811 | 2.06 / 101.27 | 6 | 24 |
3 | 13 | 1920.52 | 20 | 14.78 | 2962 | 876 | 2.94 / 102.14 | 5 | 27 |
4 | 13 | 1397.20 | 20 | 14.86 | 2282 | 678 | 3.62 / 102.82 | 5 | 33 |
5 | 13 | 837.36 | 20 | 14.99 | 1545 | 463 | 4.08 / 103.29 | 5 | 37 |
6 | 13 | 165.68 | 20 | 15.20 | 598 | 182 | 4.26 / 103.47 | 5 | 32 |
7 | 13 | 26.96 | 20 | 15.24 | 392 | 119 | 4.38 / 103.59 | 5 | 29 |
8 | 8 | 0.04 | 259 | 15.19 | 329 | 1294 | 5.68 / 104.88 | 6 | 130 |
Average= | 5.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.56 | 35 | 15.18 | 479 | 254 | 0.25 / 93.76 | 6 | 6 |
2 | 7 | 2008.20 | 40 | 14.80 | 3048 | 1804 | 2.06 / 95.56 | 6 | 23 |
3 | 13 | 1909.84 | 20 | 14.80 | 2928 | 867 | 2.93 / 96.43 | 5 | 26 |
4 | 13 | 1290.48 | 20 | 14.89 | 2142 | 638 | 3.56 / 97.06 | 5 | 34 |
5 | 13 | 864.92 | 20 | 14.99 | 1585 | 475 | 4.04 / 97.54 | 5 | 37 |
6 | 13 | 200.80 | 20 | 15.19 | 656 | 199 | 4.24 / 97.74 | 5 | 33 |
7 | 13 | 38.08 | 20 | 15.24 | 411 | 125 | 4.36 / 97.86 | 5 | 30 |
8 | 8 | 0.00 | 261 | 15.19 | 338 | 1340 | 5.70 / 99.20 | 6 | 135 |
Average= | 5.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.28 | 35 | 15.19 | 468 | 249 | 0.25 / 88.12 | 6 | 7 |
2 | 7 | 2007.96 | 40 | 14.80 | 3048 | 1804 | 2.05 / 89.93 | 7 | 23 |
3 | 13 | 1917.48 | 20 | 14.80 | 2935 | 869 | 2.92 / 90.80 | 5 | 27 |
4 | 13 | 1178.04 | 20 | 14.93 | 1999 | 597 | 3.52 / 91.39 | 5 | 34 |
5 | 13 | 855.88 | 20 | 14.99 | 1565 | 469 | 3.99 / 91.86 | 5 | 37 |
6 | 13 | 84.52 | 20 | 15.24 | 492 | 150 | 4.14 / 92.01 | 5 | 29 |
7 | 8 | 0.08 | 278 | 15.20 | 352 | 1487 | 5.63 / 93.50 | 6 | 135 |
Average= | 5.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.00 | 35 | 15.20 | 481 | 256 | 0.26 / 82.23 | 6 | 6 |
2 | 7 | 2005.24 | 40 | 14.81 | 3043 | 1803 | 2.06 / 84.03 | 6 | 24 |
3 | 13 | 1922.20 | 20 | 14.80 | 2956 | 875 | 2.93 / 84.91 | 5 | 27 |
4 | 13 | 1477.92 | 20 | 14.85 | 2375 | 705 | 3.64 / 85.61 | 5 | 32 |
5 | 13 | 1031.08 | 20 | 14.94 | 1797 | 537 | 4.18 / 86.15 | 5 | 37 |
6 | 13 | 330.92 | 20 | 15.16 | 844 | 256 | 4.43 / 86.41 | 5 | 36 |
7 | 8 | 0.00 | 280 | 15.20 | 345 | 1468 | 5.90 / 87.88 | 6 | 129 |
Average= | 5.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.88 | 35 | 15.21 | 461 | 245 | 0.25 / 76.54 | 6 | 6 |
2 | 7 | 2009.04 | 40 | 14.81 | 3054 | 1809 | 2.05 / 78.35 | 6 | 23 |
3 | 13 | 1922.96 | 20 | 14.81 | 2948 | 873 | 2.93 / 79.23 | 5 | 27 |
4 | 13 | 1291.04 | 20 | 14.90 | 2154 | 642 | 3.57 / 79.87 | 5 | 34 |
5 | 13 | 963.68 | 20 | 14.96 | 1713 | 513 | 4.08 / 80.38 | 5 | 37 |
6 | 13 | 92.72 | 20 | 15.25 | 495 | 151 | 4.23 / 80.53 | 5 | 29 |
7 | 8 | 0.08 | 276 | 15.21 | 344 | 1444 | 5.68 / 81.98 | 6 | 133 |
Average= | 5.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.84 | 35 | 15.21 | 463 | 246 | 0.25 / 70.98 | 6 | 6 |
2 | 7 | 2010.00 | 40 | 14.81 | 3057 | 1811 | 2.06 / 72.79 | 6 | 24 |
3 | 13 | 1912.20 | 20 | 14.81 | 2928 | 867 | 2.92 / 73.66 | 5 | 27 |
4 | 13 | 1463.00 | 20 | 14.86 | 2376 | 706 | 3.63 / 74.36 | 5 | 33 |
5 | 13 | 642.00 | 20 | 15.08 | 1277 | 385 | 4.02 / 74.75 | 5 | 37 |
6 | 13 | 99.20 | 20 | 15.25 | 495 | 151 | 4.17 / 74.90 | 5 | 30 |
7 | 8 | 0.12 | 276 | 15.22 | 333 | 1399 | 5.57 / 76.30 | 6 | 137 |
Average= | 5.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.16 | 35 | 15.21 | 459 | 244 | 0.24 / 65.30 | 6 | 7 |
2 | 7 | 2010.28 | 40 | 14.82 | 3055 | 1811 | 2.06 / 67.11 | 6 | 24 |
3 | 13 | 1925.72 | 20 | 14.82 | 2954 | 876 | 2.93 / 67.99 | 5 | 27 |
4 | 13 | 1505.92 | 20 | 14.85 | 2426 | 721 | 3.65 / 68.71 | 5 | 33 |
5 | 13 | 831.64 | 20 | 15.01 | 1543 | 463 | 4.11 / 69.17 | 5 | 38 |
6 | 13 | 74.76 | 20 | 15.26 | 457 | 139 | 4.25 / 69.31 | 5 | 27 |
7 | 8 | 0.08 | 278 | 15.22 | 336 | 1422 | 5.68 / 70.73 | 6 | 138 |
Average= | 5.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.16 | 35 | 15.21 | 461 | 245 | 0.25 / 59.64 | 6 | 6 |
2 | 7 | 2009.80 | 40 | 14.82 | 3053 | 1810 | 2.06 / 61.45 | 6 | 24 |
3 | 13 | 1918.80 | 20 | 14.82 | 2946 | 873 | 2.93 / 62.32 | 5 | 27 |
4 | 13 | 1394.60 | 20 | 14.89 | 2287 | 681 | 3.61 / 63.00 | 5 | 33 |
5 | 13 | 828.20 | 20 | 15.02 | 1542 | 463 | 4.07 / 63.47 | 5 | 38 |
6 | 13 | 144.40 | 20 | 15.24 | 559 | 170 | 4.24 / 63.64 | 5 | 31 |
7 | 8 | 0.04 | 276 | 15.22 | 338 | 1420 | 5.66 / 65.06 | 6 | 132 |
Average= | 5.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.60 | 35 | 15.22 | 464 | 247 | 0.25 / 54.03 | 6 | 6 |
2 | 7 | 2008.68 | 40 | 14.82 | 3055 | 1811 | 2.06 / 55.84 | 6 | 24 |
3 | 13 | 1924.92 | 20 | 14.82 | 2946 | 873 | 2.93 / 56.71 | 5 | 27 |
4 | 13 | 1196.04 | 20 | 14.94 | 2024 | 605 | 3.54 / 57.32 | 5 | 35 |
5 | 13 | 872.16 | 20 | 15.00 | 1596 | 479 | 4.01 / 57.79 | 5 | 38 |
6 | 13 | 167.60 | 20 | 15.23 | 596 | 182 | 4.20 / 57.98 | 5 | 32 |
7 | 8 | 0.04 | 278 | 15.22 | 335 | 1417 | 5.61 / 59.39 | 6 | 141 |
Average= | 4.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.44 | 35 | 15.21 | 485 | 258 | 0.26 / 48.31 | 6 | 7 |
2 | 7 | 2006.72 | 41 | 14.82 | 3050 | 1853 | 2.11 / 50.16 | 7 | 24 |
3 | 13 | 1919.40 | 20 | 14.82 | 2956 | 876 | 2.99 / 51.04 | 5 | 27 |
4 | 13 | 1281.72 | 20 | 14.92 | 2135 | 637 | 3.62 / 51.67 | 5 | 34 |
5 | 13 | 967.84 | 20 | 14.98 | 1722 | 516 | 4.14 / 52.19 | 5 | 37 |
6 | 13 | 174.36 | 20 | 15.23 | 607 | 185 | 4.33 / 52.37 | 5 | 32 |
7 | 8 | 0.08 | 274 | 15.22 | 337 | 1405 | 5.73 / 53.78 | 6 | 142 |
Average= | 4.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.08 | 34 | 15.22 | 475 | 246 | 0.25 / 42.34 | 6 | 6 |
2 | 7 | 2004.28 | 40 | 14.83 | 3054 | 1812 | 2.06 / 44.15 | 6 | 24 |
3 | 13 | 1811.40 | 20 | 14.85 | 2821 | 838 | 2.90 / 44.98 | 5 | 29 |
4 | 13 | 1624.68 | 20 | 14.83 | 2584 | 766 | 3.66 / 45.75 | 5 | 32 |
5 | 13 | 1309.36 | 20 | 14.87 | 2173 | 646 | 4.31 / 46.40 | 5 | 36 |
6 | 13 | 49.92 | 20 | 15.28 | 441 | 135 | 4.44 / 46.53 | 6 | 28 |
7 | 8 | 0.12 | 276 | 15.22 | 361 | 1516 | 5.96 / 48.05 | 6 | 139 |
Average= | 4.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.80 | 34 | 15.22 | 475 | 246 | 0.25 / 36.58 | 6 | 7 |
2 | 7 | 2005.00 | 41 | 14.84 | 3055 | 1859 | 2.10 / 38.44 | 11 | 24 |
3 | 13 | 1918.44 | 20 | 14.83 | 2954 | 876 | 2.98 / 39.32 | 5 | 27 |
4 | 13 | 1373.80 | 20 | 14.90 | 2269 | 676 | 3.66 / 39.99 | 5 | 34 |
5 | 13 | 810.08 | 20 | 15.04 | 1510 | 454 | 4.11 / 40.45 | 5 | 37 |
6 | 13 | 118.76 | 20 | 15.26 | 538 | 164 | 4.28 / 40.61 | 5 | 30 |
7 | 13 | 28.68 | 20 | 15.28 | 398 | 122 | 4.40 / 40.73 | 6 | 28 |
8 | 8 | 0.04 | 255 | 15.22 | 349 | 1355 | 5.75 / 42.09 | 6 | 131 |
Average= | 4.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.24 | 34 | 15.23 | 453 | 235 | 0.23 / 30.98 | 6 | 6 |
2 | 7 | 2011.92 | 41 | 14.83 | 3065 | 1864 | 2.10 / 32.84 | 6 | 25 |
3 | 13 | 1820.92 | 20 | 14.85 | 2831 | 841 | 2.94 / 33.68 | 5 | 29 |
4 | 13 | 1303.20 | 20 | 14.92 | 2167 | 647 | 3.59 / 34.33 | 5 | 35 |
5 | 13 | 763.00 | 20 | 15.05 | 1459 | 439 | 4.02 / 34.77 | 5 | 38 |
6 | 13 | 89.88 | 20 | 15.27 | 485 | 148 | 4.17 / 34.91 | 5 | 29 |
7 | 8 | 0.12 | 274 | 15.23 | 341 | 1423 | 5.60 / 36.34 | 6 | 133 |
Average= | 4.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.24 | 33 | 15.22 | 477 | 240 | 0.24 / 25.34 | 6 | 6 |
2 | 3 | 1036.28 | 1 | 15.23 | 1801 | 27 | 0.27 / 25.36 | 5 | 19 |
3 | 7 | 2009.80 | 40 | 14.84 | 3050 | 1810 | 2.08 / 27.17 | 19 | 25 |
4 | 13 | 1913.76 | 20 | 14.84 | 2947 | 875 | 2.95 / 28.05 | 5 | 28 |
5 | 13 | 1473.32 | 20 | 14.88 | 2374 | 707 | 3.66 / 28.75 | 5 | 33 |
6 | 13 | 693.12 | 20 | 15.08 | 1349 | 407 | 4.07 / 29.16 | 5 | 38 |
7 | 13 | 121.28 | 20 | 15.26 | 522 | 159 | 4.22 / 29.32 | 5 | 30 |
8 | 8 | 0.04 | 276 | 15.23 | 338 | 1421 | 5.65 / 30.74 | 6 | 133 |
Average= | 4.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.64 | 31 | 15.22 | 464 | 219 | 0.22 / 19.64 | 6 | 7 |
2 | 10 | 1001.04 | 5 | 15.19 | 1729 | 131 | 0.35 / 19.77 | 5 | 18 |
3 | 3 | 939.60 | -1 | 15.57 | 5 | 0 | 0.13 / 19.77 | 5 | 18 |
4 | 7 | 2006.60 | 40 | 14.85 | 3045 | 1809 | 2.16 / 21.58 | 18 | 25 |
5 | 13 | 1912.64 | 20 | 14.84 | 2921 | 867 | 3.03 / 22.44 | 5 | 28 |
6 | 13 | 1266.92 | 20 | 14.94 | 2101 | 628 | 3.65 / 23.07 | 5 | 35 |
7 | 13 | 731.88 | 20 | 15.07 | 1395 | 420 | 4.07 / 23.49 | 5 | 39 |
8 | 13 | 167.88 | 20 | 15.24 | 595 | 181 | 4.26 / 23.67 | 5 | 33 |
9 | 8 | 0.04 | 278 | 15.23 | 336 | 1423 | 5.68 / 25.10 | 6 | 138 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.20 | 33 | 15.23 | 458 | 230 | 0.23 / 14.56 | 6 | 6 |
2 | 7 | 1517.76 | 41 | 15.03 | 2404 | 1481 | 1.71 / 16.04 | 6 | 26 |
3 | 13 | 1454.48 | 20 | 15.02 | 2332 | 701 | 2.41 / 16.74 | 5 | 29 |
4 | 13 | 1144.24 | 20 | 15.03 | 1939 | 583 | 2.99 / 17.32 | 5 | 33 |
5 | 13 | 705.28 | 20 | 15.11 | 1355 | 409 | 3.40 / 17.73 | 5 | 38 |
6 | 13 | 336.40 | 20 | 15.20 | 845 | 257 | 3.66 / 17.99 | 5 | 37 |
7 | 8 | 0.04 | 276 | 15.24 | 340 | 1430 | 5.09 / 19.42 | 6 | 135 |
Average= | 3.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.44 | 32 | 15.23 | 441 | 215 | 0.21 / 9.71 | 6 | 7 |
2 | 7 | 1505.52 | 40 | 15.04 | 2388 | 1437 | 1.65 / 11.15 | 14 | 26 |
3 | 13 | 1441.48 | 20 | 15.02 | 2302 | 692 | 2.34 / 11.84 | 5 | 29 |
4 | 13 | 1151.08 | 20 | 15.03 | 1951 | 586 | 2.93 / 12.43 | 5 | 33 |
5 | 13 | 706.24 | 20 | 15.10 | 1356 | 410 | 3.34 / 12.84 | 5 | 38 |
6 | 8 | 0.08 | 291 | 15.25 | 336 | 1491 | 4.83 / 14.33 | 6 | 141 |
Average= | 3.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.16 | 31 | 15.26 | 450 | 213 | 0.21 / 4.94 | 6 | 7 |
2 | 3 | 1068.36 | 2 | 15.24 | 1832 | 56 | 0.27 / 5.00 | 5 | 27 |
3 | 7 | 1515.52 | 40 | 15.04 | 2400 | 1444 | 1.71 / 6.44 | 27 | 27 |
4 | 13 | 1453.44 | 20 | 15.01 | 2327 | 699 | 2.41 / 7.14 | 5 | 30 |
5 | 13 | 1161.40 | 20 | 15.02 | 1956 | 588 | 3.00 / 7.73 | 5 | 34 |
6 | 13 | 613.92 | 20 | 15.13 | 1223 | 370 | 3.37 / 8.10 | 5 | 37 |
7 | 8 | 0.08 | 285 | 15.25 | 322 | 1399 | 4.77 / 9.50 | 6 | 129 |
Average= | 3.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.16 | 31 | 15.41 | 421 | 201 | 0.20 / 1.97 | 6 | 7 |
2 | 10 | 1024.56 | 3 | 15.23 | 1760 | 80 | 0.28 / 2.06 | 5 | 21 |
3 | 7 | 954.40 | 40 | 15.16 | 1655 | 1004 | 1.29 / 3.06 | 21 | 32 |
4 | 13 | 429.92 | 20 | 15.26 | 943 | 288 | 1.57 / 3.35 | 5 | 36 |
5 | 13 | 21.68 | 20 | 15.35 | 358 | 110 | 1.68 / 3.46 | 6 | 29 |
6 | 8 | 0.08 | 263 | 15.30 | 316 | 1272 | 2.95 / 4.73 | 6 | 134 |
Average= | 2.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 129.68 | 30 | 15.58 | 460 | 215 | 0.22 / 0.22 | 6 | 11 |
2 | 7 | 139.20 | 40 | 15.56 | 468 | 291 | 0.51 / 0.51 | 11 | 13 |
3 | 13 | 101.88 | 20 | 15.55 | 416 | 129 | 0.64 / 0.64 | 6 | 14 |
4 | 13 | 26.84 | 20 | 15.54 | 318 | 99 | 0.73 / 0.73 | 6 | 15 |
5 | 8 | 0.12 | 244 | 15.49 | 275 | 1039 | 1.77 / 1.77 | 6 | 151 |
Average= | 1.77 (KJ/cycle) |