SIO Argo Site:
Pump Diagnostics Page   



Serial= 7554 WMO= 1902279

Return

←PreviousNext→

Cycle 157 GMT 18/11/2024 15:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.32 39 14.89 406 236 0.24 / 841.24 5 16
2 7 2010.28 40 14.52 3010 1748 1.98 / 842.99 16 46
3 13 1920.80 20 14.50 2906 843 2.83 / 843.83 5 53
4 13 1506.72 20 14.50 2362 685 3.51 / 844.52 5 59
5 13 1004.72 20 14.58 1682 490 4.00 / 845.01 5 68
6 13 689.44 20 14.65 1254 367 4.37 / 845.37 5 74
7 8 0.12 259 14.87 267 1028 5.40 / 846.40 5 129
Average= 9.51
(KJ/cycle)

Cycle 156 GMT 8/11/2024 18:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.76 39 14.90 402 234 0.23 / 835.84 5 16
2 7 2010.72 41 14.51 3023 1798 2.03 / 837.63 34 48
3 13 1933.92 20 14.49 2929 849 2.88 / 838.48 5 51
4 13 1537.96 20 14.49 2395 694 3.57 / 839.18 5 57
5 13 1018.88 20 14.57 1705 497 4.07 / 839.67 5 68
6 13 484.52 20 14.74 971 286 4.36 / 839.96 5 72
7 8 0.16 259 14.87 271 1044 5.40 / 841.00 5 185
Average= 9.56
(KJ/cycle)

Cycle 155 GMT 29/10/2024 20:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.12 39 14.89 410 238 0.24 / 830.35 5 18
2 7 2013.72 40 14.51 3033 1760 2.00 / 832.11 18 47
3 13 1931.52 20 14.49 2925 848 2.85 / 832.96 5 51
4 13 1618.48 20 14.47 2508 726 3.57 / 833.68 5 57
5 13 1187.88 20 14.53 1928 560 4.13 / 834.25 5 66
6 13 521.80 20 14.72 1034 304 4.44 / 834.55 5 73
7 8 0.12 259 14.88 273 1052 5.49 / 835.60 5 134
Average= 9.60
(KJ/cycle)

Cycle 154 GMT 19/10/2024 23:47: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.52 39 14.88 403 234 0.23 / 824.87 5 17
2 7 2004.48 40 14.52 3012 1749 1.98 / 826.62 17 47
3 13 1923.24 20 14.50 2914 845 2.83 / 827.47 5 50
4 13 1718.92 20 14.47 2623 759 3.59 / 828.23 5 55
5 13 1081.00 20 14.56 1787 520 4.11 / 828.75 5 67
6 13 571.32 20 14.71 1088 320 4.43 / 829.07 5 73
7 8 0.28 259 14.88 271 1044 5.47 / 830.11 5 154
Average= 9.65
(KJ/cycle)

Cycle 153 GMT 10/10/2024 2:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 39 14.88 403 234 0.23 / 819.46 5 17
2 7 2008.64 40 14.51 3024 1755 1.99 / 821.22 17 48
3 13 1913.44 20 14.50 2896 840 2.83 / 822.06 5 51
4 13 1702.56 20 14.47 2598 752 3.58 / 822.81 5 55
5 13 1063.20 20 14.57 1765 514 4.10 / 823.33 5 66
6 13 431.96 20 14.77 891 263 4.36 / 823.59 5 70
7 8 0.08 259 14.87 273 1051 5.41 / 824.64 5 155
Average= 9.70
(KJ/cycle)

Cycle 152 GMT 30/ 9/2024 5:14: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.72 39 14.88 411 239 0.24 / 814.03 5 19
2 7 2014.76 40 14.52 3015 1751 1.99 / 815.78 19 45
3 13 1932.04 20 14.50 2913 845 2.83 / 816.62 5 51
4 13 1532.72 20 14.50 2391 693 3.53 / 817.32 5 60
5 13 1124.20 20 14.54 1847 537 4.06 / 817.86 5 67
6 13 563.36 20 14.70 1091 321 4.39 / 818.18 5 74
7 8 0.20 259 14.87 274 1055 5.44 / 819.23 5 142
Average= 9.75
(KJ/cycle)

Cycle 151 GMT 20/ 9/2024 7:51:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.56 39 14.88 414 240 0.24 / 808.57 5 20
2 7 2009.64 41 14.52 3018 1797 2.04 / 810.37 20 47
3 13 1918.92 20 14.50 2903 842 2.88 / 811.21 5 51
4 13 1717.48 20 14.47 2632 762 3.64 / 811.97 5 57
5 13 1052.76 20 14.57 1746 509 4.15 / 812.48 5 68
6 13 411.64 20 14.78 863 255 4.40 / 812.73 5 70
7 8 0.08 257 14.88 276 1055 5.46 / 813.79 5 143
Average= 9.80
(KJ/cycle)

Cycle 150 GMT 10/ 9/2024 10:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.36 39 14.88 410 238 0.24 / 802.99 5 20
2 7 2012.56 40 14.52 3011 1749 1.99 / 804.74 20 49
3 13 1923.28 20 14.51 2899 841 2.83 / 805.58 5 51
4 13 1727.24 20 14.47 2655 768 3.60 / 806.35 5 54
5 13 1075.32 20 14.57 1772 516 4.11 / 806.87 5 68
6 13 752.52 20 14.64 1339 392 4.50 / 807.26 5 73
7 8 0.20 261 14.87 276 1071 5.58 / 808.33 5 140
Average= 9.86
(KJ/cycle)

Cycle 149 GMT 31/ 8/2024 13:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.16 39 14.89 410 238 0.24 / 797.70 5 20
2 7 2009.96 40 14.52 3011 1749 1.99 / 799.45 20 47
3 13 1929.56 20 14.51 2898 841 2.83 / 800.29 5 51
4 13 1424.60 20 14.53 2236 650 3.48 / 800.94 5 60
5 13 1015.24 20 14.58 1700 496 3.97 / 801.43 5 69
6 13 478.52 20 14.74 959 283 4.26 / 801.71 5 73
7 8 -0.04 257 14.87 272 1039 5.30 / 802.75 5 147
Average= 9.91
(KJ/cycle)

Cycle 148 GMT 21/ 8/2024 16:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.52 39 14.89 408 237 0.24 / 792.20 5 21
2 7 2004.72 40 14.53 3013 1751 1.99 / 793.95 21 47
3 13 1918.96 20 14.51 2913 845 2.83 / 794.80 5 50
4 13 1608.64 20 14.49 2493 722 3.56 / 795.52 5 56
5 13 1089.80 20 14.56 1797 523 4.08 / 796.04 5 69
6 13 658.12 20 14.68 1211 356 4.43 / 796.40 5 75
7 8 0.00 259 14.88 275 1060 5.49 / 797.46 5 145
Average= 9.97
(KJ/cycle)

Cycle 147 GMT 11/ 8/2024 19:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.20 39 14.88 411 239 0.24 / 786.80 5 20
2 7 2003.04 40 14.53 3000 1744 1.98 / 788.54 20 49
3 13 1911.68 20 14.52 2900 842 2.82 / 789.38 5 51
4 13 1502.08 20 14.52 2343 680 3.50 / 790.06 5 58
5 13 1082.72 20 14.57 1793 522 4.03 / 790.59 5 67
6 13 552.56 20 14.72 1064 313 4.34 / 790.90 5 74
7 8 0.12 259 14.88 276 1064 5.40 / 791.96 5 140
Average= 10.02
(KJ/cycle)

Cycle 146 GMT 1/ 8/2024 22: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.04 39 14.89 413 240 0.24 / 781.30 5 19
2 7 2011.80 40 14.53 3013 1751 1.99 / 783.05 19 48
3 13 1922.92 20 14.51 2906 843 2.83 / 783.90 5 52
4 13 1615.48 20 14.50 2499 725 3.56 / 784.62 5 58
5 13 1078.00 20 14.57 1788 521 4.08 / 785.14 5 68
6 13 643.60 20 14.68 1193 350 4.43 / 785.49 5 75
7 8 0.08 259 14.87 277 1067 5.50 / 786.56 5 150
Average= 10.08
(KJ/cycle)

Cycle 145 GMT 23/ 7/2024 0:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.64 39 14.89 417 242 0.24 / 775.82 5 16
2 7 2005.72 40 14.53 3020 1755 2.00 / 777.58 16 47
3 13 1921.44 20 14.50 2909 844 2.84 / 778.42 5 49
4 13 1608.28 20 14.49 2502 725 3.57 / 779.15 5 57
5 13 1088.40 20 14.57 1796 523 4.09 / 779.67 5 69
6 13 550.96 20 14.72 1066 314 4.40 / 779.98 5 73
7 8 0.12 259 14.88 280 1079 5.48 / 781.06 5 146
Average= 10.14
(KJ/cycle)

Cycle 144 GMT 13/ 7/2024 3:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.16 39 14.89 411 239 0.24 / 770.28 5 16
2 7 2007.68 41 14.52 3020 1798 2.04 / 772.08 16 45
3 13 1920.84 20 14.51 2909 844 2.88 / 772.92 5 52
4 13 1625.64 20 14.48 2538 735 3.62 / 773.65 5 57
5 13 1094.40 20 14.56 1817 529 4.14 / 774.18 5 68
6 13 555.32 20 14.72 1080 318 4.46 / 774.50 5 73
7 8 0.04 259 14.88 280 1079 5.54 / 775.58 5 -99
Average= 10.21
(KJ/cycle)

Cycle 143 GMT 3/ 7/2024 6:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.60 39 14.89 409 238 0.24 / 764.68 5 17
2 7 2007.08 40 14.53 3025 1758 2.00 / 766.43 17 45
3 13 1923.48 20 14.52 2910 845 2.84 / 767.28 5 51
4 13 1827.24 20 14.46 2791 807 3.65 / 768.09 5 54
5 13 1147.68 20 14.56 1880 547 4.20 / 768.63 5 66
6 13 605.00 20 14.71 1144 337 4.53 / 768.97 5 74
7 8 0.00 261 14.88 275 1068 5.60 / 770.04 5 178
Average= 10.27
(KJ/cycle)

Cycle 142 GMT 23/ 6/2024 8:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.32 39 14.89 421 244 0.24 / 759.22 5 16
2 7 2008.44 40 14.53 3012 1751 2.00 / 760.97 16 45
3 13 1933.00 20 14.50 2933 851 2.85 / 761.82 5 50
4 13 1523.52 20 14.51 2376 690 3.54 / 762.51 5 58
5 13 1098.92 20 14.56 1812 528 4.06 / 763.04 5 68
6 13 570.40 20 14.71 1100 324 4.39 / 763.36 5 74
7 8 0.16 259 14.88 279 1075 5.46 / 764.44 5 151
Average= 10.33
(KJ/cycle)

Cycle 141 GMT 13/ 6/2024 11:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.00 39 14.88 410 238 0.24 / 753.78 5 15
2 7 2014.28 40 14.53 3035 1764 2.00 / 755.55 15 47
3 13 1922.76 20 14.51 2910 844 2.85 / 756.39 5 53
4 13 1600.00 20 14.50 2486 721 3.57 / 757.11 5 59
5 13 1055.64 20 14.58 1753 511 4.08 / 757.62 5 67
6 13 434.32 20 14.77 904 267 4.35 / 757.89 5 70
7 8 0.00 259 14.88 282 1087 5.43 / 758.98 5 198
Average= 10.40
(KJ/cycle)

Cycle 140 GMT 3/ 6/2024 14:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.80 39 14.89 416 242 0.24 / 748.31 5 17
2 7 2005.40 40 14.53 3014 1752 1.99 / 750.07 17 47
3 13 1925.48 20 14.52 2936 853 2.85 / 750.92 5 52
4 13 1532.72 20 14.51 2399 696 3.54 / 751.62 5 60
5 13 988.08 20 14.60 1678 490 4.03 / 752.10 5 68
6 13 662.80 20 14.67 1228 360 4.39 / 752.47 5 75
7 13 22.80 20 14.92 321 96 4.49 / 752.56 5 50
8 8 0.00 238 14.87 278 984 5.47 / 753.54 5 152
Average= 10.47
(KJ/cycle)

Cycle 139 GMT 24/ 5/2024 17:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.12 39 14.89 419 243 0.24 / 742.82 5 15
2 7 2012.76 40 14.53 3027 1759 2.00 / 744.58 15 48
3 13 1927.44 20 14.52 2916 847 2.85 / 745.43 5 49
4 13 1729.40 20 14.48 2652 768 3.62 / 746.20 5 56
5 13 1070.64 20 14.58 1777 518 4.14 / 746.72 5 68
6 13 444.88 20 14.77 924 273 4.41 / 746.99 5 72
7 8 0.16 259 14.89 281 1084 5.49 / 748.07 5 151
Average= 10.54
(KJ/cycle)

Cycle 138 GMT 14/ 5/2024 19:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.76 39 14.89 413 240 0.24 / 737.48 5 15
2 7 2005.32 41 14.53 3016 1797 2.04 / 739.28 15 46
3 13 1930.16 20 14.51 2934 851 2.89 / 740.13 5 50
4 13 1427.60 20 14.53 2265 658 3.55 / 740.79 5 60
5 13 1014.48 20 14.59 1701 496 4.04 / 741.29 5 69
6 13 371.68 20 14.80 822 243 4.29 / 741.53 5 70
7 8 0.08 253 14.88 279 1050 5.34 / 742.58 5 129
Average= 10.61
(KJ/cycle)

Cycle 137 GMT 4/ 5/2024 22:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.32 39 14.89 402 233 0.23 / 731.96 5 14
2 7 2012.88 41 14.53 3017 1797 2.03 / 733.76 14 48
3 13 1920.52 20 14.51 2913 845 2.88 / 734.60 5 51
4 13 1596.96 20 14.51 2474 718 3.59 / 735.32 5 57
5 13 1066.56 20 14.58 1774 517 4.11 / 735.84 5 68
6 13 527.80 20 14.73 1043 307 4.42 / 736.15 5 75
7 13 38.28 20 14.91 345 103 4.52 / 736.25 5 53
8 8 0.00 238 14.87 281 994 5.52 / 737.24 5 139
Average= 10.68
(KJ/cycle)

Cycle 136 GMT 25/ 4/2024 1:41: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.36 39 14.91 404 235 0.23 / 726.52 5 13
2 7 2004.84 40 14.53 3018 1754 1.99 / 728.27 13 48
3 13 1811.64 20 14.53 2776 807 2.80 / 729.08 5 54
4 13 1508.52 20 14.51 2365 686 3.48 / 729.77 5 59
5 13 1180.76 20 14.54 1926 560 4.04 / 730.33 5 65
6 13 511.96 20 14.74 1022 301 4.34 / 730.63 5 73
7 13 34.40 20 14.91 343 102 4.45 / 730.73 5 53
8 8 0.08 238 14.87 282 998 5.44 / 731.73 5 146
Average= 10.76
(KJ/cycle)

Cycle 135 GMT 15/ 4/2024 4:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.60 39 14.91 402 234 0.23 / 721.10 5 12
2 7 2003.56 40 14.53 3014 1752 1.99 / 722.85 12 48
3 13 1911.76 20 14.52 2901 842 2.83 / 723.70 5 52
4 13 1595.76 20 14.51 2478 719 3.55 / 724.42 5 57
5 13 1060.92 20 14.58 1769 516 4.06 / 724.93 5 68
6 13 424.96 20 14.78 900 266 4.33 / 725.20 5 71
7 13 44.88 20 14.92 355 106 4.43 / 725.30 5 53
8 8 -0.08 238 14.89 277 982 5.42 / 726.28 5 132
Average= 10.84
(KJ/cycle)

Cycle 134 GMT 5/ 4/2024 7:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.08 39 14.91 403 234 0.23 / 715.59 5 11
2 7 2014.92 40 14.53 3019 1755 1.99 / 717.34 11 48
3 13 1943.48 20 14.51 2936 852 2.84 / 718.19 5 50
4 13 1521.84 20 14.51 2382 691 3.53 / 718.89 5 59
5 13 1104.44 20 14.57 1825 532 4.06 / 719.42 5 67
6 13 671.36 20 14.67 1240 364 4.43 / 719.78 5 74
7 13 44.96 20 14.91 351 105 4.53 / 719.89 5 54
8 8 0.00 240 14.88 275 982 5.51 / 720.87 5 144
Average= 10.92
(KJ/cycle)

Cycle 133 GMT 26/ 3/2024 9:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.40 39 14.91 405 236 0.24 / 710.18 5 12
2 7 2016.92 40 14.53 3034 1763 2.00 / 711.95 12 47
3 13 1943.08 20 14.51 2931 851 2.85 / 712.80 5 53
4 13 1532.92 20 14.51 2391 694 3.54 / 713.49 5 59
5 13 1123.64 20 14.56 1850 539 4.08 / 714.03 5 67
6 13 383.48 20 14.80 834 247 4.33 / 714.28 5 70
7 13 34.12 20 14.92 342 102 4.43 / 714.38 5 55
8 8 0.08 238 14.89 275 975 5.41 / 715.35 5 138
Average= 11.01
(KJ/cycle)

Cycle 132 GMT 16/ 3/2024 12:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.36 39 14.92 396 230 0.23 / 704.68 5 10
2 7 2014.24 40 14.53 3013 1751 1.98 / 706.44 10 48
3 13 1930.36 20 14.51 2910 844 2.83 / 707.28 5 50
4 13 1736.88 20 14.48 2641 765 3.59 / 708.04 5 57
5 13 1072.12 20 14.58 1774 517 4.11 / 708.56 5 69
6 13 535.36 20 14.74 1044 308 4.42 / 708.87 5 74
7 13 42.92 20 14.92 347 104 4.52 / 708.97 5 52
8 8 0.04 238 14.89 275 975 5.49 / 709.95 5 149
Average= 11.09
(KJ/cycle)

Cycle 131 GMT 6/ 3/2024 15: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 39 14.90 390 227 0.23 / 699.25 5 10
2 7 2005.68 40 14.54 3010 1751 1.98 / 701.00 10 45
3 13 1930.48 20 14.52 2921 848 2.83 / 701.85 5 52
4 13 1629.44 20 14.50 2514 729 3.55 / 702.58 5 57
5 13 984.80 20 14.61 1659 485 4.04 / 703.06 5 68
6 13 560.56 20 14.73 1077 317 4.36 / 703.38 5 74
7 13 22.00 20 14.93 315 94 4.45 / 703.47 5 53
8 8 0.00 240 14.89 274 979 5.43 / 704.45 5 -99
Average= 11.18
(KJ/cycle)

Cycle 130 GMT 25/ 2/2024 17:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.24 39 14.92 404 235 0.24 / 693.89 5 11
2 7 2003.92 40 14.54 3003 1747 1.98 / 695.63 11 49
3 13 1910.64 20 14.52 2885 838 2.82 / 696.47 5 51
4 13 1501.52 20 14.53 2351 683 3.50 / 697.16 5 60
5 13 1060.28 20 14.58 1754 511 4.01 / 697.67 5 69
6 13 513.08 20 14.75 1010 298 4.31 / 697.97 5 75
7 13 27.96 20 14.92 326 97 4.41 / 698.06 5 55
8 8 -0.04 235 14.88 275 962 5.37 / 699.02 5 136
Average= 11.27
(KJ/cycle)

Cycle 129 GMT 15/ 2/2024 20:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.28 38 14.92 406 230 0.23 / 688.48 5 14
2 7 2014.24 40 14.54 3021 1757 1.99 / 690.23 14 45
3 13 1928.76 20 14.52 2915 847 2.83 / 691.08 5 52
4 13 1628.56 20 14.50 2517 730 3.56 / 691.81 5 58
5 13 1067.28 20 14.59 1762 514 4.08 / 692.33 5 69
6 13 421.20 20 14.79 882 261 4.34 / 692.59 5 72
7 13 22.20 20 14.94 319 95 4.43 / 692.68 5 53
8 8 0.04 238 14.90 274 972 5.41 / 693.65 5 224
Average= 11.37
(KJ/cycle)

Cycle 128 GMT 5/ 2/2024 23:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.80 38 14.92 400 227 0.23 / 683.04 5 10
2 7 2004.72 40 14.54 3017 1755 1.98 / 684.80 10 48
3 13 1916.24 20 14.52 2892 840 2.82 / 685.64 5 52
4 13 1607.04 20 14.52 2483 721 3.54 / 686.36 5 56
5 13 1060.92 20 14.59 1763 514 4.06 / 686.87 5 69
6 13 519.80 20 14.76 1025 303 4.36 / 687.17 5 73
7 13 21.24 20 14.94 318 95 4.45 / 687.27 5 57
8 8 0.12 238 14.90 276 979 5.43 / 688.25 5 212
Average= 11.47
(KJ/cycle)

Cycle 127 GMT 27/ 1/2024 2:26: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.04 38 14.91 398 225 0.23 / 677.65 5 12
2 7 2010.40 40 14.54 3014 1753 1.98 / 679.40 12 46
3 13 1925.52 20 14.53 2903 844 2.82 / 680.25 5 52
4 13 1623.56 20 14.51 2510 728 3.55 / 680.97 5 59
5 13 984.56 20 14.62 1662 486 4.04 / 681.46 5 68
6 13 458.72 20 14.78 944 279 4.32 / 681.74 5 73
7 13 26.48 20 14.94 324 97 4.41 / 681.84 5 57
8 8 -0.04 238 14.90 276 979 5.39 / 682.81 5 186
Average= 11.57
(KJ/cycle)

Cycle 126 GMT 17/ 1/2024 5: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.00 38 14.91 399 226 0.23 / 672.18 5 14
2 7 2005.56 40 14.54 3018 1755 1.98 / 673.93 14 48
3 13 1919.08 20 14.53 2900 843 2.82 / 674.77 5 53
4 13 1719.44 20 14.49 2644 766 3.59 / 675.54 5 57
5 13 1064.96 20 14.60 1766 516 4.11 / 676.06 5 69
6 13 437.00 20 14.80 913 270 4.38 / 676.33 5 73
7 13 44.00 20 14.94 351 105 4.48 / 676.43 5 56
8 8 0.08 238 14.90 280 993 5.47 / 677.42 5 157
Average= 11.68
(KJ/cycle)

Cycle 125 GMT 7/ 1/2024 7:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.68 38 14.91 412 233 0.23 / 666.76 5 15
2 7 2004.52 40 14.54 3016 1754 1.99 / 668.51 15 50
3 13 1917.28 20 14.53 2897 842 2.83 / 669.35 5 52
4 13 1499.16 20 14.55 2344 682 3.51 / 670.03 5 58
5 13 967.80 20 14.63 1633 478 3.99 / 670.51 5 71
6 13 634.28 20 14.71 1182 348 4.34 / 670.86 5 75
7 13 18.04 20 14.94 317 95 4.43 / 670.95 5 58
8 8 0.00 236 14.89 283 994 5.43 / 671.95 5 136
Average= 11.79
(KJ/cycle)

Cycle 124 GMT 28/12/2023 10:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.92 38 14.91 413 234 0.23 / 661.23 5 13
2 7 2011.80 40 14.55 3024 1760 1.99 / 662.99 13 47
3 13 1925.60 20 14.52 2910 845 2.84 / 663.84 5 51
4 13 1606.16 20 14.52 2496 725 3.56 / 664.56 5 59
5 13 1157.12 20 14.57 1901 554 4.12 / 665.12 5 67
6 13 493.80 20 14.77 998 295 4.41 / 665.41 5 74
7 13 17.04 20 14.94 323 97 4.51 / 665.51 5 52
8 8 -0.04 238 14.89 286 1014 5.52 / 666.52 5 138
Average= 11.90
(KJ/cycle)

Cycle 123 GMT 18/12/2023 13:31:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.32 38 14.91 401 227 0.23 / 655.75 5 13
2 7 2005.60 40 14.55 3009 1751 1.98 / 657.50 13 48
3 13 1926.84 20 14.53 2921 849 2.83 / 658.35 5 52
4 13 1625.56 20 14.52 2514 730 3.56 / 659.08 5 58
5 13 1080.16 20 14.60 1793 524 4.08 / 659.60 5 68
6 13 533.96 20 14.76 1050 310 4.39 / 659.91 5 77
7 13 19.60 20 14.94 323 97 4.49 / 660.01 5 58
8 8 0.00 238 14.90 280 993 5.48 / 661.00 5 138
Average= 12.02
(KJ/cycle)

Cycle 122 GMT 8/12/2023 16:19:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.20 38 14.90 405 229 0.23 / 650.24 5 17
2 7 2015.24 41 14.54 3031 1807 2.04 / 652.05 17 50
3 13 1931.84 20 14.53 2932 852 2.89 / 652.90 5 53
4 13 1525.76 20 14.53 2378 691 3.58 / 653.59 5 59
5 13 1086.48 20 14.60 1789 522 4.10 / 654.11 5 70
6 13 532.36 20 14.75 1046 309 4.41 / 654.42 5 77
7 13 17.36 20 14.94 317 95 4.50 / 654.52 5 60
8 8 -0.04 238 14.90 283 1004 5.51 / 655.52 5 139
Average= 12.14
(KJ/cycle)

Cycle 121 GMT 28/11/2023 19: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.84 38 14.90 412 233 0.23 / 644.82 5 19
2 7 2009.32 40 14.55 3014 1754 1.99 / 646.57 19 46
3 13 1927.08 20 14.53 2916 847 2.83 / 647.42 5 52
4 13 1417.00 20 14.56 2231 650 3.48 / 648.07 5 62
5 13 1103.64 20 14.58 1820 531 4.02 / 648.60 5 68
6 13 541.08 20 14.75 1052 310 4.33 / 648.91 5 77
7 13 39.24 20 14.93 348 104 4.43 / 649.01 5 58
8 8 0.00 238 14.89 282 999 5.43 / 650.01 5 145
Average= 12.26
(KJ/cycle)

Cycle 120 GMT 18/11/2023 21:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.64 38 14.91 416 236 0.24 / 639.48 5 18
2 7 2005.08 40 14.56 3021 1759 2.00 / 641.24 18 48
3 13 1910.76 20 14.53 2886 839 2.83 / 642.07 5 54
4 13 1399.04 20 14.56 2207 643 3.48 / 642.72 5 61
5 13 1080.44 20 14.60 1778 519 4.00 / 643.24 5 69
6 13 422.00 20 14.80 889 263 4.26 / 643.50 5 74
7 8 0.20 257 14.90 283 1084 5.34 / 644.58 5 145
Average= 12.40
(KJ/cycle)

Cycle 119 GMT 9/11/2023 0:18:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.64 38 14.91 416 236 0.24 / 634.06 5 20
2 7 2009.20 40 14.55 3019 1757 1.99 / 635.82 20 46
3 13 1918.00 20 14.54 2901 844 2.84 / 636.66 5 53
4 13 1501.72 20 14.55 2349 684 3.52 / 637.34 5 59
5 13 1055.88 20 14.61 1756 513 4.03 / 637.86 5 69
6 13 527.28 20 14.76 1041 307 4.34 / 638.16 5 76
7 8 0.12 257 14.91 281 1077 5.42 / 639.24 5 136
Average= 12.53
(KJ/cycle)

Cycle 118 GMT 30/10/2023 3: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.12 38 14.91 419 237 0.24 / 628.69 5 19
2 7 2006.80 40 14.56 2998 1746 1.98 / 630.43 19 48
3 13 1925.48 20 14.54 2912 847 2.83 / 631.28 5 50
4 13 1513.44 20 14.54 2362 687 3.52 / 631.97 5 58
5 13 1080.12 20 14.60 1785 521 4.04 / 632.49 5 68
6 13 434.12 20 14.80 904 268 4.31 / 632.75 5 71
7 8 0.00 257 14.90 279 1068 5.37 / 633.82 5 139
Average= 12.68
(KJ/cycle)

Cycle 117 GMT 20/10/2023 5:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.96 39 14.91 410 238 0.24 / 623.21 5 21
2 7 2011.68 40 14.55 3019 1757 2.00 / 624.97 21 47
3 13 1916.00 20 14.54 2901 844 2.84 / 625.81 5 51
4 13 1599.08 20 14.53 2481 721 3.56 / 626.53 5 57
5 13 1157.40 20 14.58 1889 551 4.11 / 627.08 5 65
6 13 504.16 20 14.77 1002 296 4.41 / 627.38 5 74
7 8 0.04 259 14.91 277 1070 5.48 / 628.45 5 141
Average= 12.83
(KJ/cycle)

Cycle 116 GMT 10/10/2023 8:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.24 39 14.91 404 235 0.23 / 617.82 5 18
2 7 2003.12 40 14.56 3000 1747 1.98 / 619.57 18 47
3 13 1912.20 20 14.54 2874 836 2.82 / 620.40 5 51
4 13 1602.64 20 14.53 2471 718 3.54 / 621.12 5 57
5 13 1043.68 20 14.62 1729 506 4.04 / 621.63 5 68
6 13 501.72 20 14.78 987 292 4.33 / 621.92 5 74
7 8 0.20 259 14.91 273 1054 5.39 / 622.97 5 142
Average= 12.98
(KJ/cycle)

Cycle 115 GMT 30/ 9/2023 11:29: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.60 39 14.92 418 243 0.24 / 612.53 5 20
2 7 2008.80 40 14.55 3020 1758 2.00 / 614.29 20 47
3 13 1913.56 20 14.53 2904 844 2.84 / 615.14 5 53
4 13 1403.36 20 14.56 2208 643 3.49 / 615.78 5 61
5 13 996.52 20 14.62 1667 487 3.98 / 616.27 5 71
6 13 458.60 20 14.80 932 276 4.25 / 616.54 5 72
7 8 -0.08 257 14.91 272 1042 5.29 / 617.58 5 154
Average= 13.14
(KJ/cycle)

Cycle 114 GMT 20/ 9/2023 14:10: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.00 38 14.91 415 235 0.24 / 606.98 5 19
2 7 2010.12 40 14.56 3024 1761 2.00 / 608.74 39 48
3 13 1929.68 20 14.54 2920 849 2.85 / 609.59 5 52
4 13 1730.52 20 14.51 2645 768 3.61 / 610.35 5 57
5 13 1188.56 20 14.58 1928 562 4.18 / 610.92 5 66
6 13 526.16 20 14.77 1036 306 4.48 / 611.22 5 72
7 8 0.04 259 14.91 277 1070 5.55 / 612.29 5 145
Average= 13.31
(KJ/cycle)

Cycle 113 GMT 10/ 9/2023 16:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.20 38 14.91 428 242 0.24 / 601.54 5 19
2 7 2008.28 40 14.56 3013 1755 2.00 / 603.29 19 49
3 13 1926.44 20 14.54 2909 846 2.84 / 604.14 5 51
4 13 1506.48 20 14.55 2358 686 3.53 / 604.82 5 61
5 13 986.24 20 14.63 1662 486 4.02 / 605.31 5 70
6 13 653.44 20 14.72 1201 354 4.37 / 605.66 5 75
7 13 16.24 20 14.95 314 94 4.46 / 605.76 5 51
8 8 0.00 238 14.91 277 983 5.45 / 606.74 5 159
Average= 13.48
(KJ/cycle)

Cycle 112 GMT 31/ 8/2023 19:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.80 38 14.92 403 228 0.23 / 596.12 5 19
2 7 2004.72 40 14.56 3004 1750 1.98 / 597.87 19 48
3 13 1908.44 20 14.54 2902 844 2.82 / 598.72 5 52
4 13 1595.76 20 14.53 2476 720 3.54 / 599.44 5 59
5 13 1057.28 20 14.61 1767 516 4.06 / 599.95 5 68
6 13 407.28 20 14.82 870 258 4.32 / 600.21 5 71
7 13 39.80 20 14.95 345 103 4.42 / 600.31 5 54
8 8 0.08 235 14.91 280 981 5.40 / 601.29 5 131
Average= 13.67
(KJ/cycle)

Cycle 111 GMT 21/ 8/2023 22:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.92 38 14.92 409 232 0.23 / 590.69 5 21
2 7 2014.56 40 14.55 3026 1761 1.99 / 592.45 21 46
3 13 1929.88 20 14.54 2916 848 2.84 / 593.30 5 53
4 13 1521.16 20 14.54 2382 693 3.53 / 593.99 5 60
5 13 1086.40 20 14.61 1789 523 4.06 / 594.51 5 68
6 13 547.84 20 14.76 1059 313 4.37 / 594.83 5 75
7 8 0.00 257 14.91 279 1069 5.44 / 595.89 5 133
Average= 13.86
(KJ/cycle)

Cycle 110 GMT 12/ 8/2023 1:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.76 38 14.92 416 236 0.24 / 585.38 5 19
2 7 2010.88 41 14.56 3011 1797 2.03 / 587.18 19 48
3 13 1912.72 20 14.55 2893 842 2.88 / 588.02 5 53
4 13 1396.96 20 14.58 2198 641 3.52 / 588.66 5 62
5 13 990.32 20 14.63 1663 487 4.00 / 589.15 5 70
6 13 378.44 20 14.84 823 244 4.25 / 589.40 5 69
7 8 0.08 255 14.92 279 1061 5.31 / 590.46 5 133
Average= 14.06
(KJ/cycle)

Cycle 109 GMT 2/ 8/2023 3:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.84 38 14.92 430 244 0.24 / 579.86 5 21
2 7 2004.16 40 14.56 3019 1758 2.00 / 581.62 21 50
3 13 1909.60 20 14.55 2895 842 2.84 / 582.46 5 54
4 13 1699.72 20 14.52 2605 756 3.60 / 583.22 5 57
5 13 1041.60 20 14.63 1733 507 4.11 / 583.72 5 69
6 13 613.80 20 14.74 1161 342 4.45 / 584.07 5 76
7 8 0.04 259 14.92 280 1082 5.53 / 585.15 5 150
Average= 14.27
(KJ/cycle)

Cycle 108 GMT 23/ 7/2023 6:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.96 38 14.92 415 235 0.24 / 574.36 5 19
2 7 2013.12 40 14.57 3002 1750 1.98 / 576.11 19 49
3 13 1924.76 20 14.54 2907 845 2.83 / 576.95 5 52
4 13 1716.08 20 14.52 2638 766 3.60 / 577.72 5 55
5 13 1058.12 20 14.62 1756 513 4.11 / 578.23 5 70
6 13 530.16 20 14.78 1041 308 4.42 / 578.54 5 74
7 8 0.24 257 14.92 281 1077 5.49 / 579.62 5 135
Average= 14.49
(KJ/cycle)

Cycle 107 GMT 13/ 7/2023 9:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.24 38 14.92 425 241 0.24 / 568.93 5 19
2 7 2007.40 40 14.57 3003 1750 1.99 / 570.68 19 51
3 13 1927.60 20 14.55 2905 845 2.84 / 571.53 5 54
4 13 1507.00 20 14.55 2351 684 3.52 / 572.21 5 61
5 13 1077.76 20 14.61 1781 520 4.04 / 572.73 5 69
6 13 513.32 20 14.78 1024 303 4.34 / 573.03 5 75
7 8 0.12 255 14.92 286 1088 5.43 / 574.12 5 132
Average= 14.72
(KJ/cycle)

Cycle 106 GMT 3/ 7/2023 12:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.20 38 14.93 419 238 0.24 / 563.51 5 18
2 7 2006.40 40 14.56 3023 1761 2.00 / 565.27 18 48
3 13 1926.56 20 14.55 2930 853 2.85 / 566.12 5 53
4 13 1608.60 20 14.54 2491 724 3.58 / 566.85 5 57
5 13 957.60 20 14.65 1629 477 4.05 / 567.32 5 71
6 13 426.80 20 14.82 902 267 4.32 / 567.59 5 73
7 8 0.00 257 14.92 286 1097 5.42 / 568.69 5 137
Average= 14.97
(KJ/cycle)

Cycle 105 GMT 23/ 6/2023 15:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.32 38 14.93 415 235 0.24 / 558.10 5 17
2 7 2009.92 40 14.56 3021 1759 1.99 / 559.85 17 49
3 13 1914.76 20 14.54 2911 847 2.84 / 560.70 5 55
4 13 1707.76 20 14.52 2622 761 3.60 / 561.46 5 57
5 13 1029.24 20 14.63 1722 504 4.11 / 561.97 5 70
6 13 382.88 20 14.84 833 247 4.35 / 562.21 5 71
7 8 0.04 255 14.93 278 1058 5.41 / 563.27 5 136
Average= 15.22
(KJ/cycle)

Cycle 104 GMT 13/ 6/2023 17:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.76 38 14.92 419 238 0.24 / 552.71 5 15
2 7 2012.24 40 14.58 3001 1750 1.99 / 554.46 15 46
3 13 1934.84 20 14.55 2922 850 2.84 / 555.31 5 53
4 13 1521.48 20 14.55 2380 693 3.53 / 556.00 5 59
5 13 998.48 20 14.64 1674 490 4.02 / 556.49 5 70
6 13 470.88 20 14.80 962 285 4.31 / 556.78 5 73
7 8 0.16 257 14.92 282 1081 5.39 / 557.86 5 153
Average= 15.50
(KJ/cycle)

Cycle 103 GMT 3/ 6/2023 20:37:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.60 38 14.93 410 233 0.23 / 547.34 5 14
2 7 2007.76 40 14.57 3016 1758 1.99 / 549.09 14 48
3 13 1816.84 20 14.57 2782 811 2.80 / 549.90 5 55
4 13 1608.00 20 14.54 2500 727 3.53 / 550.63 5 57
5 13 1057.72 20 14.62 1763 516 4.04 / 551.15 5 69
6 13 401.68 20 14.83 864 256 4.30 / 551.40 5 70
7 8 0.00 257 14.92 279 1070 5.37 / 552.47 5 136
Average= 15.78
(KJ/cycle)

Cycle 102 GMT 24/ 5/2023 23:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.40 38 14.93 411 233 0.23 / 541.90 5 14
2 7 2005.20 40 14.57 3021 1761 1.99 / 543.66 14 49
3 13 1923.20 20 14.56 2922 851 2.84 / 544.51 5 53
4 13 1609.08 20 14.54 2485 723 3.57 / 545.24 5 58
5 13 1052.96 20 14.62 1755 513 4.08 / 545.75 5 69
6 13 410.72 20 14.83 877 260 4.34 / 546.01 5 73
7 8 0.04 257 14.92 285 1093 5.43 / 547.10 5 158
Average= 16.09
(KJ/cycle)

Cycle 101 GMT 15/ 5/2023 2:19:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.84 38 14.93 402 228 0.23 / 536.42 5 14
2 7 2007.96 40 14.57 3018 1759 1.99 / 538.18 38 48
3 13 1925.04 20 14.55 2921 850 2.84 / 539.03 5 52
4 13 1523.72 20 14.55 2393 696 3.53 / 539.73 5 60
5 13 995.92 20 14.64 1682 492 4.03 / 540.22 5 70
6 13 566.44 20 14.76 1092 322 4.35 / 540.54 5 76
7 13 47.16 20 14.95 364 109 4.46 / 540.65 5 56
8 8 0.16 238 14.92 287 1019 5.48 / 541.67 5 171
Average= 16.41
(KJ/cycle)

Cycle 100 GMT 5/ 5/2023 5: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.92 38 14.94 415 236 0.24 / 531.06 5 12
2 7 2009.24 41 14.56 3017 1801 2.04 / 532.86 12 49
3 13 1926.20 20 14.56 2910 847 2.88 / 533.71 5 52
4 13 1411.84 20 14.58 2221 648 3.53 / 534.36 5 61
5 13 1003.40 20 14.64 1683 493 4.02 / 534.85 5 70
6 13 453.28 20 14.81 939 278 4.30 / 535.13 5 72
7 13 21.76 20 14.96 319 95 4.40 / 535.22 5 55
8 8 0.04 235 14.92 277 971 5.37 / 536.19 5 131
Average= 16.76
(KJ/cycle)

Cycle 99 GMT 25/ 4/2023 7:41: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.48 38 14.94 416 236 0.24 / 525.69 5 12
2 7 2008.52 40 14.56 3030 1765 2.00 / 527.46 31 49
3 13 1923.80 20 14.56 2925 852 2.85 / 528.31 5 53
4 13 1424.44 20 14.58 2248 656 3.51 / 528.96 5 62
5 13 1021.88 20 14.63 1722 504 4.01 / 529.47 5 70
6 13 404.48 20 14.83 868 257 4.27 / 529.73 5 72
7 13 36.12 20 14.96 344 103 4.37 / 529.83 5 56
8 8 -0.12 235 14.92 284 996 5.37 / 530.82 5 141
Average= 17.12
(KJ/cycle)

Cycle 98 GMT 15/ 4/2023 10: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.24 38 14.94 399 227 0.23 / 520.17 5 11
2 7 2011.28 40 14.57 3022 1761 1.99 / 521.94 11 49
3 13 1921.68 20 14.56 2910 847 2.84 / 522.78 5 52
4 13 1614.44 20 14.55 2506 729 3.56 / 523.51 5 59
5 13 1182.28 20 14.60 1930 564 4.13 / 524.08 5 68
6 13 523.68 20 14.79 1037 307 4.43 / 524.38 5 77
7 8 0.16 257 14.93 280 1074 5.51 / 525.46 5 151
Average= 17.52
(KJ/cycle)

Cycle 97 GMT 5/ 4/2023 12:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.40 38 14.94 421 239 0.24 / 514.73 5 12
2 7 2010.36 40 14.57 3024 1762 2.00 / 516.49 12 48
3 13 1916.00 20 14.56 2913 848 2.85 / 517.34 5 52
4 13 1506.76 20 14.57 2358 687 3.54 / 518.03 5 61
5 13 1086.52 20 14.62 1801 527 4.06 / 518.55 5 69
6 13 434.36 20 14.82 912 270 4.33 / 518.82 5 75
7 13 43.04 20 14.96 361 108 4.44 / 518.93 5 58
8 8 0.08 238 14.92 286 1016 5.46 / 519.95 5 161
Average= 17.93
(KJ/cycle)

Cycle 96 GMT 26/ 3/2023 15:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.80 38 14.94 413 234 0.23 / 509.14 5 12
2 7 2011.96 40 14.57 3009 1754 1.99 / 510.89 12 49
3 13 1922.12 20 14.56 2903 845 2.83 / 511.74 5 51
4 13 1717.76 20 14.52 2632 764 3.60 / 512.50 5 57
5 13 1171.12 20 14.60 1924 562 4.16 / 513.06 5 68
6 13 504.92 20 14.80 1014 300 4.46 / 513.36 5 75
7 13 29.92 20 14.97 345 103 4.56 / 513.47 5 58
8 8 0.00 238 14.92 288 1023 5.59 / 514.49 5 147
Average= 18.37
(KJ/cycle)

Cycle 95 GMT 16/ 3/2023 18:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.80 38 14.94 418 237 0.24 / 503.62 5 13
2 7 2018.84 40 14.57 3031 1766 2.00 / 505.38 13 48
3 13 1942.64 20 14.56 2939 856 2.86 / 506.24 5 53
4 13 1519.60 20 14.56 2382 694 3.55 / 506.93 5 62
5 13 1003.24 20 14.65 1689 495 4.05 / 507.43 5 69
6 13 568.68 20 14.77 1108 327 4.38 / 507.75 5 78
7 13 42.20 20 14.96 371 111 4.49 / 507.86 5 59
8 8 -0.08 238 14.92 293 1040 5.53 / 508.90 5 150
Average= 18.85
(KJ/cycle)

Cycle 94 GMT 6/ 3/2023 20:55: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.48 38 14.94 428 243 0.24 / 498.24 5 13
2 7 2015.92 40 14.57 3025 1763 2.01 / 500.00 13 48
3 13 1931.28 20 14.55 2935 854 2.86 / 500.86 5 54
4 13 1409.80 20 14.59 2248 656 3.52 / 501.51 5 63
5 13 999.60 20 14.65 1693 496 4.01 / 502.01 5 71
6 13 361.44 20 14.85 820 244 4.26 / 502.25 5 71
7 13 28.04 20 14.97 339 101 4.36 / 502.36 5 59
8 8 0.04 233 14.92 294 1022 5.38 / 503.38 5 134
Average= 19.36
(KJ/cycle)

Cycle 93 GMT 24/ 2/2023 23:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.52 38 14.93 418 237 0.24 / 492.75 5 13
2 7 2004.12 40 14.58 3021 1762 2.00 / 494.51 13 48
3 13 1916.40 20 14.56 2928 853 2.85 / 495.36 5 52
4 13 1498.92 20 14.58 2351 686 3.54 / 496.05 5 62
5 13 1058.64 20 14.63 1783 522 4.06 / 496.57 5 70
6 13 507.80 20 14.80 1023 303 4.36 / 496.87 5 77
7 13 18.92 20 14.97 333 100 4.46 / 496.97 5 57
8 8 0.08 235 14.93 292 1024 5.49 / 498.00 5 137
Average= 19.92
(KJ/cycle)

Cycle 92 GMT 15/ 2/2023 2:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.44 38 14.93 417 237 0.24 / 487.20 5 12
2 7 2010.44 40 14.58 3035 1770 2.01 / 488.97 12 50
3 13 1917.32 20 14.56 2913 848 2.85 / 489.82 5 52
4 13 1598.96 20 14.55 2488 724 3.58 / 490.54 5 59
5 13 1058.48 20 14.63 1775 519 4.10 / 491.06 5 69
6 13 518.24 20 14.79 1036 306 4.40 / 491.37 5 76
7 13 35.40 20 14.96 354 106 4.51 / 491.48 5 60
8 8 0.04 238 14.92 292 1037 5.55 / 492.51 5 138
Average= 20.52
(KJ/cycle)

Cycle 91 GMT 5/ 2/2023 5:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.44 38 14.93 422 239 0.24 / 481.80 5 15
2 7 2008.60 41 14.58 3014 1802 2.04 / 483.60 15 50
3 13 1923.80 20 14.55 2933 854 2.89 / 484.46 5 52
4 13 1417.96 20 14.59 2244 655 3.55 / 485.11 5 63
5 13 1003.44 20 14.65 1687 494 4.04 / 485.61 5 69
6 13 353.80 20 14.86 802 238 4.28 / 485.84 5 72
7 13 11.68 20 14.97 325 97 4.38 / 485.94 5 57
8 8 -0.04 235 14.92 292 1024 5.40 / 486.97 5 140
Average= 21.17
(KJ/cycle)

Cycle 90 GMT 26/ 1/2023 7:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.24 38 14.93 418 237 0.24 / 476.34 5 15
2 7 2013.92 40 14.58 3023 1763 2.00 / 478.10 15 48
3 13 1930.28 20 14.56 2927 852 2.85 / 478.95 5 53
4 13 1617.12 20 14.55 2513 731 3.58 / 479.69 5 61
5 13 970.60 20 14.66 1650 484 4.07 / 480.17 5 72
6 13 428.04 20 14.83 904 268 4.34 / 480.44 5 76
7 13 38.92 20 14.97 359 107 4.44 / 480.55 5 59
8 8 0.00 235 14.92 290 1017 5.46 / 481.56 5 136
Average= 21.89
(KJ/cycle)

Cycle 89 GMT 16/ 1/2023 10:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.64 38 14.93 419 238 0.24 / 471.01 5 16
2 7 2003.04 40 14.59 3002 1752 1.99 / 472.76 16 49
3 13 1916.68 20 14.57 2900 845 2.83 / 473.61 5 53
4 13 1414.52 20 14.59 2248 656 3.49 / 474.26 5 63
5 13 1000.64 20 14.65 1687 494 3.98 / 474.76 5 69
6 13 362.80 20 14.86 812 241 4.23 / 475.00 5 69
7 13 26.76 20 14.97 338 101 4.33 / 475.10 5 56
8 8 0.00 235 14.93 286 1003 5.33 / 476.10 5 149
Average= 22.67
(KJ/cycle)

Cycle 88 GMT 6/ 1/2023 13:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.48 38 14.93 414 235 0.23 / 465.57 5 16
2 7 2003.32 41 14.58 2997 1792 2.03 / 467.37 16 50
3 13 1915.00 20 14.57 2892 843 2.87 / 468.21 5 53
4 13 1498.32 20 14.58 2341 683 3.55 / 468.89 5 61
5 13 977.36 20 14.67 1645 483 4.03 / 469.37 5 72
6 13 528.16 20 14.79 1037 307 4.34 / 469.68 5 75
7 13 33.20 20 14.97 340 102 4.44 / 469.78 5 57
8 8 0.12 235 14.93 282 989 5.43 / 470.77 5 144
Average= 23.54
(KJ/cycle)

Cycle 87 GMT 27/12/2022 16:22:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.44 38 14.94 411 233 0.23 / 460.18 5 18
2 7 2013.56 40 14.58 3029 1767 2.00 / 461.95 18 51
3 13 1925.68 20 14.57 2927 853 2.85 / 462.80 5 53
4 13 1514.72 20 14.58 2370 691 3.54 / 463.49 5 61
5 13 985.24 20 14.66 1654 485 4.03 / 463.97 5 70
6 13 427.84 20 14.84 903 268 4.30 / 464.24 5 74
7 13 16.80 20 14.98 320 96 4.39 / 464.34 5 57
8 8 0.08 235 14.93 285 1000 5.39 / 465.34 5 135
Average= 24.49
(KJ/cycle)

Cycle 86 GMT 17/12/2022 19:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.84 38 14.93 424 241 0.24 / 454.76 5 19
2 7 2012.60 40 14.58 3013 1757 2.00 / 456.52 19 49
3 13 1919.32 20 14.57 2914 849 2.85 / 457.37 5 53
4 13 1599.84 20 14.56 2489 725 3.57 / 458.09 5 60
5 13 1051.28 20 14.64 1751 513 4.08 / 458.60 5 71
6 13 410.00 20 14.85 879 261 4.35 / 458.86 5 71
7 8 0.04 255 14.94 284 1082 5.43 / 459.95 5 134
Average= 25.55
(KJ/cycle)

Cycle 85 GMT 7/12/2022 22: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.28 38 14.93 413 234 0.23 / 449.40 5 19
2 7 2006.00 40 14.59 3010 1757 1.99 / 451.16 19 48
3 13 1923.60 20 14.57 2904 846 2.84 / 452.00 5 52
4 13 1506.52 20 14.58 2360 688 3.53 / 452.69 5 61
5 13 885.64 20 14.70 1537 452 3.98 / 453.14 5 72
6 13 464.12 20 14.83 946 281 4.26 / 453.43 5 74
7 8 0.08 255 14.94 287 1093 5.35 / 454.52 5 138
Average= 26.74
(KJ/cycle)

Cycle 84 GMT 28/11/2022 0:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.92 38 14.94 422 240 0.24 / 443.95 5 20
2 7 2007.00 40 14.59 3012 1758 2.00 / 445.70 20 48
3 13 1922.72 20 14.58 2901 846 2.84 / 446.55 5 55
4 13 1502.60 20 14.58 2348 685 3.53 / 447.23 5 60
5 13 1077.40 20 14.64 1797 526 4.05 / 447.76 5 70
6 13 539.00 20 14.79 1071 317 4.37 / 448.08 5 75
7 8 -0.04 257 14.93 284 1090 5.46 / 449.17 5 147
Average= 28.07
(KJ/cycle)

Cycle 83 GMT 18/11/2022 3:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.16 38 14.93 428 243 0.24 / 438.59 5 20
2 7 2006.48 40 14.59 3004 1753 2.00 / 440.35 20 49
3 13 1913.52 20 14.58 2878 839 2.84 / 441.18 5 54
4 13 1497.96 20 14.59 2350 686 3.52 / 441.87 5 62
5 13 986.04 20 14.67 1662 488 4.01 / 442.36 5 70
6 13 442.08 20 14.84 924 274 4.28 / 442.63 5 72
7 8 0.16 255 14.94 282 1074 5.36 / 443.71 5 138
Average= 29.58
(KJ/cycle)

Cycle 82 GMT 8/11/2022 6:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.96 38 14.93 430 244 0.24 / 433.25 5 22
2 7 2004.88 40 14.60 3011 1758 2.00 / 435.01 22 49
3 13 1919.12 20 14.58 2921 852 2.85 / 435.86 5 53
4 13 1421.12 20 14.60 2259 660 3.51 / 436.52 5 64
5 13 909.00 20 14.69 1558 458 3.97 / 436.98 5 73
6 13 372.76 20 14.86 830 247 4.22 / 437.22 5 71
7 8 0.16 257 14.94 293 1125 5.34 / 438.35 5 161
Average= 31.31
(KJ/cycle)

Cycle 81 GMT 29/10/2022 9:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.48 38 14.94 426 242 0.24 / 427.70 5 22
2 7 2003.28 41 14.59 3014 1803 2.04 / 429.50 22 50
3 13 1907.24 20 14.57 2904 846 2.89 / 430.35 5 53
4 13 1582.64 20 14.57 2472 720 3.61 / 431.07 5 61
5 13 1117.24 20 14.63 1844 540 4.15 / 431.61 5 70
6 13 460.28 20 14.83 953 283 4.43 / 431.89 5 75
7 8 0.00 257 14.94 290 1113 5.55 / 433.01 5 143
Average= 33.31
(KJ/cycle)

Cycle 80 GMT 19/10/2022 12:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.60 38 14.93 432 245 0.25 / 422.31 5 25
2 7 2005.60 41 14.59 3017 1805 2.05 / 424.12 25 49
3 13 1917.68 20 14.58 2899 845 2.90 / 424.96 5 54
4 13 1490.08 20 14.58 2337 681 3.58 / 425.64 5 62
5 13 958.16 20 14.68 1632 479 4.06 / 426.12 5 72
6 13 328.40 20 14.89 763 227 4.28 / 426.35 5 67
7 8 0.20 253 14.94 294 1111 5.39 / 427.46 5 133
Average= 35.62
(KJ/cycle)

Cycle 79 GMT 9/10/2022 15: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.24 38 14.93 450 255 0.26 / 416.79 5 26
2 7 2005.88 40 14.59 3022 1764 2.02 / 418.56 26 48
3 13 1922.64 20 14.58 2914 850 2.87 / 419.41 5 53
4 13 1503.96 20 14.59 2357 688 3.56 / 420.10 5 62
5 13 1185.84 20 14.61 1952 570 4.13 / 420.67 5 68
6 13 412.44 20 14.85 883 262 4.39 / 420.93 5 74
7 8 0.08 259 14.93 294 1137 5.53 / 422.07 5 142
Average= 38.37
(KJ/cycle)

Cycle 78 GMT 29/ 9/2022 17:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.84 38 14.93 427 242 0.24 / 411.27 5 27
2 7 2006.96 40 14.59 3021 1763 2.01 / 413.03 27 50
3 13 1922.60 20 14.58 2919 851 2.86 / 413.88 5 52
4 13 1607.68 20 14.56 2502 729 3.59 / 414.61 5 60
5 13 1058.72 20 14.65 1763 517 4.10 / 415.13 5 71
6 13 406.32 20 14.86 877 261 4.36 / 415.39 5 73
7 8 0.00 255 14.94 302 1151 5.51 / 416.54 5 137
Average= 41.65
(KJ/cycle)

Cycle 77 GMT 19/ 9/2022 20:34: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.68 38 14.94 423 240 0.24 / 405.94 5 24
2 7 2009.56 40 14.59 3023 1764 2.00 / 407.70 24 48
3 13 1927.12 20 14.57 2935 855 2.86 / 408.56 5 55
4 13 1414.76 20 14.60 2239 654 3.51 / 409.21 5 63
5 13 1005.92 20 14.66 1699 498 4.01 / 409.71 5 71
6 13 263.40 20 14.91 675 201 4.21 / 409.91 5 64
7 13 32.08 20 14.98 344 103 4.32 / 410.01 5 55
8 8 0.00 234 14.94 290 1014 5.33 / 411.03 5 145
Average= 45.67
(KJ/cycle)

Cycle 76 GMT 9/ 9/2022 23: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.76 38 14.94 417 237 0.24 / 400.51 5 24
2 7 2011.36 40 14.60 3024 1766 2.00 / 402.27 24 50
3 13 1920.48 20 14.58 2923 852 2.86 / 403.12 5 54
4 13 1499.96 20 14.59 2363 690 3.54 / 403.81 5 62
5 13 1069.84 20 14.65 1790 524 4.07 / 404.34 5 68
6 13 423.32 20 14.85 901 268 4.34 / 404.61 5 70
7 8 0.12 255 14.95 286 1090 5.43 / 405.70 5 131
Average= 50.71
(KJ/cycle)

Cycle 75 GMT 31/ 8/2022 1:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.88 38 14.94 434 246 0.25 / 395.07 5 26
2 7 2013.20 41 14.59 3041 1819 2.07 / 396.89 26 47
3 13 1928.48 20 14.58 2925 853 2.92 / 397.74 5 54
4 13 1416.96 20 14.60 2250 657 3.58 / 398.40 5 63
5 13 990.04 20 14.67 1666 489 4.06 / 398.89 5 71
6 13 441.68 20 14.84 921 273 4.34 / 399.16 5 72
7 8 0.00 255 14.94 291 1109 5.45 / 400.27 5 136
Average= 57.18
(KJ/cycle)

Cycle 74 GMT 21/ 8/2022 4:39: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.80 38 14.94 439 249 0.25 / 389.55 5 24
2 7 2016.60 40 14.60 3032 1771 2.02 / 391.32 24 49
3 13 1934.68 20 14.58 2947 859 2.88 / 392.18 5 52
4 13 1626.36 20 14.57 2527 736 3.62 / 392.91 5 57
5 13 1065.40 20 14.66 1778 521 4.14 / 393.43 5 71
6 13 418.32 20 14.86 891 265 4.40 / 393.70 5 72
7 8 0.12 257 14.95 293 1126 5.53 / 394.82 5 141
Average= 65.80
(KJ/cycle)

Cycle 73 GMT 11/ 8/2022 7:41: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.24 38 14.95 432 245 0.25 / 384.09 5 24
2 7 2003.28 40 14.61 3006 1757 2.00 / 385.84 24 50
3 13 1912.64 20 14.59 2914 850 2.85 / 386.69 5 54
4 13 1610.20 20 14.57 2506 730 3.58 / 387.42 5 59
5 13 1062.08 20 14.66 1777 521 4.10 / 387.94 5 71
6 13 318.64 20 14.91 748 223 4.33 / 388.17 5 67
7 8 -0.04 255 14.95 296 1128 5.46 / 389.30 5 134
Average= 77.86
(KJ/cycle)

Cycle 72 GMT 1/ 8/2022 10:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.12 38 14.95 420 239 0.24 / 378.77 5 24
2 7 2009.04 40 14.60 3018 1763 2.00 / 380.53 24 48
3 13 1926.16 20 14.59 2914 850 2.85 / 381.38 5 54
4 13 1405.96 20 14.61 2242 655 3.51 / 382.04 5 63
5 13 982.32 20 14.68 1664 489 4.00 / 382.53 5 70
6 13 242.56 20 14.93 651 194 4.19 / 382.72 5 63
7 8 0.08 255 14.95 294 1121 5.31 / 383.84 5 144
Average= 95.96
(KJ/cycle)

Cycle 71 GMT 22/ 7/2022 13:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.00 38 14.95 434 247 0.25 / 373.32 5 23
2 7 2004.80 40 14.61 3009 1758 2.01 / 375.07 23 48
3 13 1918.56 20 14.59 2919 852 2.86 / 375.93 5 54
4 13 1596.76 20 14.58 2492 727 3.58 / 376.65 5 60
5 13 1064.00 20 14.66 1764 517 4.10 / 377.17 5 70
6 13 410.64 20 14.86 886 263 4.36 / 377.43 5 70
7 8 0.00 255 14.95 288 1098 5.46 / 378.53 5 131
Average= 126.18
(KJ/cycle)

Cycle 70 GMT 12/ 7/2022 16:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.24 38 14.96 418 238 0.24 / 367.83 5 22
2 7 2005.96 40 14.61 3017 1763 2.00 / 369.60 22 49
3 13 1917.92 20 14.59 2927 854 2.85 / 370.45 5 52
4 13 1613.44 20 14.58 2500 729 3.58 / 371.18 5 60
5 13 1066.80 20 14.66 1774 520 4.10 / 371.70 5 70
6 13 423.84 20 14.87 891 265 4.37 / 371.97 5 69
7 8 0.12 255 14.96 289 1102 5.47 / 373.07 5 137
Average= 186.53
(KJ/cycle)

Cycle 69 GMT 2/ 7/2022 18:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.60 38 14.96 421 239 0.24 / 362.44 5 20
2 7 2005.80 40 14.61 3030 1771 2.01 / 364.21 20 50
3 13 1918.28 20 14.60 2921 853 2.86 / 365.06 5 53
4 13 1609.08 20 14.59 2507 732 3.59 / 365.79 5 60
5 13 963.52 20 14.70 1643 483 4.08 / 366.27 5 72
6 13 341.12 20 14.90 781 233 4.31 / 366.51 5 65
7 8 0.04 255 14.96 286 1091 5.40 / 367.60 5 139
Average= 367.60
(KJ/cycle)

Cycle 67 GMT 13/ 6/2022 0:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.72 38 14.97 419 238 0.24 / 357.01 5 17
2 7 2012.16 40 14.61 3025 1768 2.01 / 358.78 17 50
3 13 1922.16 20 14.60 2918 852 2.86 / 359.63 5 54
4 13 1508.28 20 14.60 2369 692 3.55 / 360.32 5 62
5 13 972.92 20 14.69 1656 487 4.04 / 360.81 5 72
6 13 439.00 20 14.87 919 273 4.31 / 361.08 5 71
7 8 0.00 255 14.97 292 1115 5.42 / 362.20 5 161
Average= 5.33
(KJ/cycle)

Cycle 66 GMT 3/ 6/2022 3: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.48 38 14.98 409 233 0.23 / 351.63 5 16
2 7 2012.76 41 14.61 3030 1815 2.05 / 353.44 16 49
3 13 1922.72 20 14.60 2911 850 2.90 / 354.29 5 54
4 13 1388.04 20 14.64 2201 644 3.54 / 354.94 5 63
5 13 962.36 20 14.70 1637 481 4.02 / 355.42 5 72
6 13 422.92 20 14.87 900 268 4.29 / 355.69 5 73
7 8 0.12 253 14.97 286 1083 5.37 / 356.77 5 146
Average= 5.32
(KJ/cycle)

Cycle 65 GMT 24/ 5/2022 5:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.88 38 14.98 440 250 0.25 / 346.15 5 17
2 7 2009.60 40 14.62 3019 1766 2.02 / 347.92 17 50
3 13 1922.92 20 14.60 2929 855 2.87 / 348.78 5 55
4 13 1602.40 20 14.60 2499 730 3.60 / 349.51 5 61
5 13 1063.84 20 14.68 1779 522 4.12 / 350.03 5 72
6 13 408.96 20 14.89 879 262 4.39 / 350.29 5 72
7 8 0.00 255 14.98 290 1108 5.49 / 351.40 5 169
Average= 5.32
(KJ/cycle)

Cycle 64 GMT 14/ 5/2022 8:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.28 38 14.97 443 252 0.25 / 340.84 5 16
2 7 2012.76 41 14.62 3014 1807 2.06 / 342.64 16 51
3 13 1921.16 20 14.61 2903 848 2.91 / 343.49 5 54
4 13 1300.52 20 14.66 2091 613 3.52 / 344.10 5 66
5 13 808.28 20 14.76 1426 421 3.94 / 344.53 5 74
6 13 382.20 20 14.90 844 252 4.19 / 344.78 5 72
7 8 0.04 250 14.98 301 1127 5.32 / 345.90 5 134
Average= 5.32
(KJ/cycle)

Cycle 63 GMT 4/ 5/2022 11:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.16 38 14.99 436 248 0.25 / 335.32 5 18
2 7 2013.68 40 14.62 3039 1777 2.03 / 337.10 18 51
3 13 1925.24 20 14.61 2936 858 2.88 / 337.95 5 55
4 13 1410.04 20 14.64 2244 657 3.54 / 338.61 5 64
5 13 992.52 20 14.70 1682 495 4.04 / 339.11 5 73
6 13 555.60 20 14.82 1088 322 4.36 / 339.43 5 78
7 8 -0.04 253 14.98 305 1156 5.51 / 340.58 5 131
Average= 5.32
(KJ/cycle)

Cycle 62 GMT 24/ 4/2022 13:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.36 37 14.99 419 232 0.23 / 330.04 5 15
2 7 2009.88 40 14.62 3033 1774 2.01 / 331.81 30 50
3 13 1925.48 20 14.60 2939 858 2.86 / 332.67 5 53
4 13 1394.08 20 14.65 2208 647 3.51 / 333.32 5 65
5 13 900.48 20 14.74 1552 458 3.97 / 333.77 5 72
6 13 267.56 20 14.95 680 203 4.17 / 333.98 5 67
7 8 0.08 250 14.99 292 1094 5.27 / 335.07 5 132
Average= 5.32
(KJ/cycle)

Cycle 61 GMT 14/ 4/2022 16:19: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.28 37 14.99 435 241 0.24 / 324.61 5 15
2 7 2012.08 41 14.62 3009 1804 2.04 / 326.41 15 50
3 13 1922.04 20 14.62 2898 847 2.89 / 327.26 5 54
4 13 1402.08 20 14.65 2207 647 3.54 / 327.91 5 64
5 13 988.08 20 14.71 1667 490 4.03 / 328.40 5 72
6 13 536.96 20 14.84 1057 314 4.34 / 328.71 5 80
7 13 19.80 20 15.03 327 98 4.44 / 328.81 5 59
8 8 0.08 231 14.99 288 997 5.44 / 329.80 5 137
Average= 5.32
(KJ/cycle)

Cycle 60 GMT 4/ 4/2022 19: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.56 38 15.00 429 245 0.24 / 319.18 5 14
2 7 2007.28 40 14.63 3004 1758 2.00 / 320.94 14 51
3 13 1923.76 20 14.61 2922 854 2.86 / 321.79 5 55
4 13 1497.36 20 14.63 2356 689 3.55 / 322.48 5 62
5 13 1045.20 20 14.70 1759 517 4.06 / 323.00 5 71
6 13 282.48 20 14.95 713 213 4.28 / 323.21 5 71
7 8 0.00 253 14.99 305 1157 5.43 / 324.37 5 144
Average= 5.32
(KJ/cycle)

Cycle 59 GMT 25/ 3/2022 21:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.92 38 15.00 435 248 0.25 / 313.74 5 16
2 7 2004.56 41 14.64 3017 1811 2.06 / 315.55 16 52
3 13 1918.16 20 14.62 2918 853 2.91 / 316.40 5 55
4 13 1611.52 20 14.61 2509 733 3.65 / 317.14 5 62
5 13 875.04 20 14.76 1524 450 4.10 / 317.59 5 74
6 13 248.28 20 14.98 648 194 4.29 / 317.78 5 69
7 13 29.04 20 15.04 343 103 4.39 / 317.88 5 58
8 8 -0.04 233 15.00 300 1048 5.44 / 318.93 5 167
Average= 5.32
(KJ/cycle)

Cycle 58 GMT 16/ 3/2022 0:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.00 38 15.00 431 246 0.25 / 308.13 5 16
2 7 2011.80 40 14.63 3033 1775 2.02 / 309.91 16 51
3 13 1920.52 20 14.62 2914 852 2.87 / 310.76 5 53
4 13 1593.00 20 14.61 2490 728 3.60 / 311.49 5 61
5 13 1134.60 20 14.69 1861 547 4.15 / 312.03 5 70
6 13 466.96 20 14.89 971 289 4.44 / 312.32 5 78
7 13 53.72 20 15.03 381 115 4.55 / 312.44 5 61
8 8 0.08 233 15.00 302 1055 5.61 / 313.49 5 140
Average= 5.31
(KJ/cycle)

Cycle 57 GMT 6/ 3/2022 3:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.40 38 15.01 442 252 0.25 / 302.67 5 14
2 7 2003.96 40 14.65 3004 1760 2.01 / 304.43 14 51
3 13 1815.44 20 14.65 2767 811 2.82 / 305.24 5 56
4 13 1509.60 20 14.65 2347 688 3.51 / 305.93 5 64
5 13 954.60 20 14.74 1625 479 3.99 / 306.41 5 72
6 13 514.24 20 14.87 1027 305 4.30 / 306.71 5 78
7 13 29.16 20 15.04 348 105 4.40 / 306.82 5 60
8 8 0.04 233 15.00 306 1069 5.47 / 307.89 5 132
Average= 5.31
(KJ/cycle)

Cycle 56 GMT 24/ 2/2022 6:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.28 38 15.02 431 246 0.25 / 297.13 5 14
2 7 2009.32 40 14.64 3033 1776 2.02 / 298.90 14 49
3 13 1937.20 20 14.62 2942 860 2.88 / 299.76 5 55
4 13 1409.64 20 14.66 2229 654 3.54 / 300.42 5 64
5 13 1199.72 20 14.67 1958 574 4.11 / 300.99 5 69
6 13 418.84 20 14.91 890 265 4.38 / 301.26 5 75
7 13 17.92 20 15.05 329 99 4.47 / 301.35 5 57
8 8 0.04 233 15.00 304 1062 5.54 / 302.42 5 143
Average= 5.31
(KJ/cycle)

Cycle 55 GMT 14/ 2/2022 9: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.56 38 15.02 443 253 0.25 / 291.61 5 13
2 7 2012.92 40 14.64 3037 1778 2.03 / 293.39 13 52
3 13 1925.64 20 14.63 2921 855 2.89 / 294.25 5 56
4 13 1505.92 20 14.65 2373 695 3.58 / 294.94 5 64
5 13 866.32 20 14.78 1512 447 4.03 / 295.39 5 74
6 13 554.68 20 14.86 1089 324 4.35 / 295.71 5 77
7 13 22.16 20 15.05 345 104 4.46 / 295.82 5 59
8 8 0.00 229 15.01 309 1062 5.52 / 296.88 5 130
Average= 5.30
(KJ/cycle)

Cycle 54 GMT 4/ 2/2022 11:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.40 38 15.02 433 247 0.25 / 286.10 5 16
2 7 2003.08 40 14.65 3017 1768 2.02 / 287.87 16 51
3 13 1912.72 20 14.64 2908 851 2.87 / 288.72 5 56
4 13 1504.80 20 14.65 2352 689 3.56 / 289.41 5 63
5 13 1062.92 20 14.72 1766 520 4.08 / 289.93 5 70
6 13 401.88 20 14.93 880 263 4.34 / 290.19 5 75
7 13 16.64 20 15.06 333 100 4.44 / 290.29 5 57
8 8 0.00 231 15.01 309 1071 5.51 / 291.36 5 130
Average= 5.30
(KJ/cycle)

Cycle 53 GMT 25/ 1/2022 14:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.96 38 15.03 431 246 0.25 / 280.67 5 16
2 7 2009.68 40 14.64 3014 1765 2.01 / 282.43 16 50
3 13 1913.52 20 14.63 2905 850 2.86 / 283.28 5 55
4 13 1496.72 20 14.66 2347 688 3.55 / 283.97 5 63
5 13 981.80 20 14.75 1665 491 4.04 / 284.46 5 74
6 13 347.00 20 14.97 782 234 4.27 / 284.69 5 71
7 13 24.88 20 15.07 341 103 4.38 / 284.80 5 59
8 8 0.16 231 15.02 304 1055 5.43 / 285.85 5 134
Average= 5.29
(KJ/cycle)

Cycle 52 GMT 15/ 1/2022 17:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.00 38 15.04 440 251 0.25 / 275.25 5 17
2 7 2009.76 40 14.65 3022 1771 2.02 / 277.03 17 50
3 13 1924.64 20 14.63 2934 858 2.88 / 277.88 5 55
4 13 1519.76 20 14.65 2390 700 3.58 / 278.58 5 62
5 13 992.36 20 14.75 1681 496 4.08 / 279.08 5 72
6 13 243.40 20 15.01 651 195 4.27 / 279.28 5 65
7 13 15.00 20 15.08 327 99 4.37 / 279.37 5 58
8 8 0.00 231 15.03 301 1045 5.42 / 280.42 5 149
Average= 5.29
(KJ/cycle)

Cycle 51 GMT 5/ 1/2022 19:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.16 38 15.04 448 256 0.26 / 269.94 5 17
2 7 2007.28 41 14.65 3010 1808 2.06 / 271.75 17 52
3 13 1916.64 20 14.64 2892 847 2.91 / 272.60 5 55
4 13 1389.20 20 14.69 2207 648 3.56 / 273.25 5 64
5 13 865.56 20 14.80 1506 446 4.00 / 273.69 5 74
6 13 234.60 20 15.02 640 192 4.20 / 273.88 5 64
7 8 -0.04 248 15.04 300 1119 5.32 / 275.00 5 137
Average= 5.29
(KJ/cycle)

Cycle 50 GMT 26/12/2021 22:19:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.72 38 15.04 447 255 0.26 / 264.48 5 19
2 7 2008.48 40 14.64 3014 1765 2.02 / 266.25 19 51
3 13 1927.24 20 14.63 2928 857 2.88 / 267.10 5 55
4 13 1508.72 20 14.66 2364 693 3.57 / 267.80 5 63
5 13 1078.04 20 14.73 1797 529 4.10 / 268.32 5 71
6 13 306.52 20 15.00 731 219 4.32 / 268.54 5 66
7 8 0.04 250 15.04 304 1143 5.46 / 269.69 5 142
Average= 5.29
(KJ/cycle)

Cycle 49 GMT 17/12/2021 0:59: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.32 38 15.04 436 249 0.25 / 259.12 5 20
2 7 2013.84 40 14.64 3041 1781 2.03 / 260.90 20 49
3 13 1922.40 20 14.64 2934 859 2.89 / 261.76 5 54
4 13 1510.32 20 14.66 2383 699 3.59 / 262.46 5 63
5 13 854.52 20 14.81 1493 442 4.03 / 262.90 5 73
6 13 212.88 20 15.04 606 182 4.21 / 263.09 5 62
7 8 0.12 248 15.05 305 1138 5.35 / 264.23 5 130
Average= 5.28
(KJ/cycle)

Cycle 48 GMT 7/12/2021 3:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.56 37 15.05 453 252 0.25 / 253.65 5 21
2 7 2006.24 40 14.66 3030 1777 2.03 / 255.43 21 51
3 13 1917.80 20 14.65 2919 855 2.88 / 256.29 5 55
4 13 1601.04 20 14.65 2503 733 3.62 / 257.02 5 61
5 13 955.76 20 14.79 1631 482 4.10 / 257.50 5 72
6 13 310.40 20 15.01 734 220 4.32 / 257.72 5 66
7 8 0.08 250 15.06 306 1152 5.47 / 258.87 5 137
Average= 5.28
(KJ/cycle)

Cycle 47 GMT 27/11/2021 6:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.76 37 15.05 436 243 0.24 / 248.16 5 20
2 7 2010.04 40 14.66 3026 1774 2.02 / 249.93 20 52
3 13 1931.68 20 14.65 2922 856 2.87 / 250.79 5 55
4 13 1614.88 20 14.65 2515 737 3.61 / 251.53 5 61
5 13 977.20 20 14.79 1663 492 4.10 / 252.02 5 75
6 13 332.52 20 15.01 770 231 4.33 / 252.25 5 69
7 8 0.04 250 15.06 306 1152 5.49 / 253.40 5 134
Average= 5.28
(KJ/cycle)

Cycle 46 GMT 17/11/2021 9:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.00 37 15.05 452 252 0.25 / 242.75 5 22
2 7 2003.76 40 14.66 3034 1779 2.03 / 244.53 22 50
3 13 1910.32 20 14.65 2904 851 2.88 / 245.38 5 54
4 13 1485.08 20 14.69 2337 687 3.57 / 246.07 5 64
5 13 949.00 20 14.80 1614 478 4.05 / 246.55 5 74
6 13 306.48 20 15.01 740 222 4.27 / 246.77 5 68
7 13 16.44 20 15.11 329 99 4.37 / 246.87 5 56
8 8 0.04 229 15.06 304 1048 5.42 / 247.92 5 161
Average= 5.27
(KJ/cycle)

Cycle 45 GMT 7/11/2021 12:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.04 37 15.06 447 249 0.25 / 237.44 5 20
2 7 2007.96 40 14.66 3031 1777 2.03 / 239.21 27 50
3 13 1918.96 20 14.66 2907 852 2.88 / 240.07 5 53
4 13 1387.96 20 14.71 2207 649 3.53 / 240.72 5 65
5 13 880.16 20 14.83 1526 453 3.98 / 241.17 5 74
6 13 225.96 20 15.05 631 190 4.17 / 241.36 5 68
7 8 0.12 250 15.07 303 1142 5.31 / 242.50 5 145
Average= 5.27
(KJ/cycle)

Cycle 44 GMT 28/10/2021 15: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.96 37 15.06 460 256 0.26 / 232.01 5 22
2 7 2006.60 40 14.66 3033 1779 2.03 / 233.79 22 52
3 13 1925.24 20 14.66 2931 859 2.89 / 234.65 5 56
4 13 1511.80 20 14.68 2380 699 3.59 / 235.35 5 63
5 13 970.80 20 14.80 1656 490 4.08 / 235.84 5 74
6 13 221.44 20 15.06 623 188 4.27 / 236.03 5 67
7 8 -0.08 250 15.07 308 1160 5.43 / 237.19 5 150
Average= 5.27
(KJ/cycle)

Cycle 43 GMT 18/10/2021 17:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.28 37 15.07 450 251 0.25 / 226.55 5 23
2 7 2009.68 40 14.66 3040 1783 2.03 / 228.34 23 51
3 13 1820.36 20 14.67 2803 822 2.86 / 229.16 5 57
4 13 1617.24 20 14.66 2526 741 3.60 / 229.90 5 61
5 13 1044.84 20 14.78 1751 518 4.11 / 230.42 5 73
6 13 289.84 20 15.03 717 216 4.33 / 230.63 5 70
7 8 0.20 246 15.07 303 1123 5.45 / 231.76 5 136
Average= 5.27
(KJ/cycle)

Cycle 42 GMT 8/10/2021 20:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.64 37 15.07 446 249 0.25 / 221.17 5 23
2 7 2008.32 41 14.66 3034 1824 2.07 / 223.00 23 51
3 13 1913.48 20 14.66 2912 854 2.93 / 223.85 5 55
4 13 1394.40 20 14.72 2225 655 3.58 / 224.51 5 67
5 13 957.68 20 14.81 1638 485 4.07 / 224.99 5 75
6 13 204.16 20 15.07 601 181 4.25 / 225.17 5 65
7 8 0.00 246 15.08 305 1131 5.38 / 226.30 5 131
Average= 5.26
(KJ/cycle)

Cycle 41 GMT 28/ 9/2021 23: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.96 37 15.07 451 251 0.25 / 215.77 5 26
2 7 2015.16 40 14.66 3047 1787 2.04 / 217.55 26 50
3 13 1930.60 20 14.65 2938 861 2.90 / 218.41 5 55
4 13 1303.08 20 14.75 2107 622 3.52 / 219.04 5 68
5 13 985.44 20 14.81 1678 497 4.02 / 219.53 5 73
6 13 321.28 20 15.03 764 230 4.25 / 219.76 5 72
7 13 20.36 20 15.13 339 103 4.35 / 219.86 5 56
8 8 0.08 229 15.08 307 1060 5.41 / 220.93 5 178
Average= 5.26
(KJ/cycle)

Cycle 40 GMT 19/ 9/2021 1:52:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.56 37 15.08 451 252 0.25 / 210.34 5 26
2 7 2003.68 41 14.67 3030 1822 2.07 / 212.16 26 51
3 13 1917.64 20 14.67 2921 857 2.93 / 213.02 5 56
4 13 1391.24 20 14.73 2231 657 3.59 / 213.67 5 64
5 13 970.28 20 14.82 1658 491 4.08 / 214.17 5 74
6 13 234.72 20 15.07 640 193 4.27 / 214.36 5 68
7 8 0.16 248 15.09 309 1156 5.43 / 215.51 5 132
Average= 5.26
(KJ/cycle)

Cycle 39 GMT 9/ 9/2021 4:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.20 37 15.08 444 248 0.25 / 204.84 5 25
2 7 2010.00 40 14.68 3037 1783 2.03 / 206.62 25 52
3 13 1913.36 20 14.67 2926 858 2.89 / 207.48 5 57
4 13 1598.20 20 14.69 2494 733 3.62 / 208.22 5 62
5 13 939.28 20 14.84 1618 480 4.10 / 208.70 5 73
6 13 293.52 20 15.05 732 220 4.32 / 208.92 5 72
7 13 8.16 20 15.14 326 99 4.42 / 209.02 5 61
8 8 -0.04 229 15.08 310 1071 5.49 / 210.09 5 129
Average= 5.25
(KJ/cycle)

Cycle 38 GMT 30/ 8/2021 7:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.12 37 15.09 447 250 0.25 / 199.36 5 22
2 7 2014.00 40 14.68 3042 1786 2.04 / 201.15 22 51
3 13 1931.28 20 14.67 2944 864 2.90 / 202.01 5 55
4 13 1623.68 20 14.68 2534 744 3.64 / 202.76 5 62
5 13 944.68 20 14.84 1619 481 4.12 / 203.24 5 75
6 13 292.20 20 15.06 721 217 4.34 / 203.46 5 72
7 8 0.04 248 15.09 304 1138 5.48 / 204.59 5 138
Average= 5.25
(KJ/cycle)

Cycle 37 GMT 20/ 8/2021 9:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.60 37 15.10 433 242 0.24 / 193.99 5 23
2 7 2003.44 40 14.68 3023 1775 2.02 / 195.76 23 52
3 13 1916.24 20 14.68 2917 856 2.87 / 196.62 5 56
4 13 1400.84 20 14.75 2228 657 3.53 / 197.28 5 64
5 13 982.60 20 14.83 1676 497 4.03 / 197.77 5 75
6 13 237.28 20 15.08 650 196 4.22 / 197.97 5 68
7 8 0.00 248 15.10 306 1146 5.37 / 199.11 5 142
Average= 5.24
(KJ/cycle)

Cycle 36 GMT 10/ 8/2021 12:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.24 37 15.10 447 250 0.25 / 188.74 5 22
2 7 2008.08 40 14.69 3031 1781 2.03 / 190.52 22 52
3 13 1925.28 20 14.68 2925 859 2.89 / 191.38 5 55
4 13 1335.08 20 14.77 2141 632 3.52 / 192.01 5 68
5 13 833.20 20 14.88 1464 436 3.96 / 192.44 5 76
6 13 197.16 20 15.10 590 178 4.14 / 192.62 5 67
7 8 0.12 246 15.11 302 1123 5.26 / 193.75 5 135
Average= 5.24
(KJ/cycle)

Cycle 35 GMT 31/ 7/2021 15: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.00 37 15.10 431 241 0.24 / 183.23 5 22
2 7 2006.88 40 14.69 3023 1776 2.02 / 185.01 22 53
3 13 1924.00 20 14.69 2919 858 2.87 / 185.87 5 57
4 13 1524.04 20 14.72 2384 702 3.58 / 186.57 5 62
5 13 986.20 20 14.84 1671 496 4.07 / 187.07 5 74
6 13 440.20 20 15.01 937 281 4.35 / 187.35 5 77
7 8 -0.04 248 15.11 304 1139 5.49 / 188.49 5 133
Average= 5.24
(KJ/cycle)

Cycle 34 GMT 21/ 7/2021 17:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.56 37 15.11 443 248 0.25 / 177.83 5 21
2 7 2004.24 40 14.69 3043 1788 2.04 / 179.62 21 52
3 13 1811.68 20 14.71 2771 815 2.85 / 180.44 5 57
4 13 1400.40 20 14.76 2232 659 3.51 / 181.10 5 65
5 13 970.80 20 14.84 1661 493 4.00 / 181.59 5 75
6 13 413.44 20 15.02 892 268 4.27 / 181.86 5 77
7 13 18.20 20 15.16 339 103 4.37 / 181.96 5 60
8 8 -0.08 225 15.11 304 1034 5.41 / 182.99 5 130
Average= 5.23
(KJ/cycle)

Cycle 33 GMT 11/ 7/2021 20:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.08 37 15.12 447 250 0.25 / 172.34 5 21
2 7 2014.60 40 14.69 3037 1785 2.03 / 174.12 21 52
3 13 1923.00 20 14.69 2929 861 2.90 / 174.98 5 57
4 13 1607.08 20 14.71 2503 736 3.63 / 175.72 5 63
5 13 950.00 20 14.86 1637 487 4.12 / 176.20 5 75
6 13 198.40 20 15.11 601 182 4.30 / 176.39 5 68
7 13 48.72 20 15.16 386 117 4.42 / 176.50 5 59
8 13 28.84 20 15.15 359 109 4.53 / 176.61 5 60
9 8 0.24 208 15.11 310 974 5.50 / 177.59 5 148
Average= 5.22
(KJ/cycle)

Cycle 32 GMT 1/ 7/2021 23: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.28 37 15.13 449 251 0.25 / 166.96 5 21
2 7 2003.16 40 14.70 3027 1780 2.03 / 168.74 21 53
3 13 1911.08 20 14.70 2913 856 2.89 / 169.59 5 56
4 13 1490.88 20 14.74 2356 695 3.58 / 170.29 5 65
5 13 958.76 20 14.86 1644 489 4.07 / 170.78 5 75
6 13 213.36 20 15.11 616 186 4.26 / 170.96 5 68
7 8 0.20 248 15.13 300 1126 5.38 / 172.09 5 143
Average= 5.21
(KJ/cycle)

Cycle 31 GMT 22/ 6/2021 1:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.08 37 15.12 456 255 0.26 / 161.52 5 19
2 7 2003.76 41 14.70 3007 1812 2.07 / 163.34 19 53
3 13 1917.44 20 14.70 2903 853 2.92 / 164.19 5 56
4 13 1503.56 20 14.74 2373 700 3.62 / 164.89 5 66
5 13 871.60 20 14.89 1525 454 4.07 / 165.34 5 76
6 13 226.84 20 15.11 634 192 4.27 / 165.54 5 67
7 8 0.16 246 15.13 314 1169 5.43 / 166.70 5 130
Average= 5.21
(KJ/cycle)

Cycle 30 GMT 12/ 6/2021 4:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.76 37 15.13 450 252 0.25 / 156.03 5 19
2 7 2006.60 40 14.71 3011 1772 2.02 / 157.80 19 52
3 13 1911.04 20 14.70 2908 855 2.88 / 158.66 5 55
4 13 1484.04 20 14.75 2354 694 3.57 / 159.35 5 64
5 13 949.60 20 14.87 1628 484 4.06 / 159.84 5 74
6 13 412.48 20 15.04 888 267 4.32 / 160.10 5 77
7 8 -0.28 248 15.13 311 1167 5.49 / 161.27 5 130
Average= 5.20
(KJ/cycle)

Cycle 29 GMT 2/ 6/2021 7:11: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.48 37 15.13 437 245 0.24 / 150.73 5 20
2 7 2011.04 40 14.70 3028 1780 2.03 / 152.51 20 53
3 13 1829.80 20 14.71 2805 825 2.85 / 153.33 5 58
4 13 1322.60 20 14.79 2131 630 3.48 / 153.96 5 67
5 13 913.68 20 14.88 1579 470 3.95 / 154.43 5 75
6 13 248.04 20 15.11 667 202 4.15 / 154.63 5 70
7 8 0.20 244 15.13 310 1144 5.30 / 155.78 5 130
Average= 5.19
(KJ/cycle)

Cycle 28 GMT 23/ 5/2021 9:34: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.48 37 15.14 451 253 0.25 / 145.20 5 19
2 7 2005.84 40 14.71 3032 1784 2.04 / 146.98 19 52
3 13 1916.88 20 14.71 2925 861 2.90 / 147.84 5 56
4 13 1599.72 20 14.73 2499 736 3.63 / 148.58 5 63
5 13 1039.80 20 14.85 1745 518 4.15 / 149.10 5 73
6 13 279.44 20 15.10 708 214 4.37 / 149.31 5 70
7 13 16.00 20 15.18 329 100 4.47 / 149.41 5 59
8 8 -0.04 229 15.14 309 1071 5.54 / 150.48 5 153
Average= 5.19
(KJ/cycle)

Cycle 27 GMT 13/ 5/2021 12:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.68 38 15.13 451 259 0.26 / 139.75 5 19
2 7 2016.04 40 14.71 3045 1792 2.05 / 141.55 19 52
3 13 1929.40 20 14.71 2931 862 2.91 / 142.41 5 56
4 13 1423.60 20 14.78 2265 670 3.58 / 143.08 5 66
5 13 994.92 20 14.86 1692 503 4.09 / 143.58 5 74
6 13 225.00 20 15.12 638 193 4.28 / 143.77 5 68
7 8 -0.08 248 15.14 312 1171 5.45 / 144.94 5 173
Average= 5.18
(KJ/cycle)

Cycle 26 GMT 3/ 5/2021 14:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.16 38 15.14 452 260 0.26 / 134.16 5 18
2 7 2013.56 40 14.71 3041 1789 2.05 / 135.95 18 53
3 13 1934.32 20 14.71 2945 866 2.92 / 136.81 5 57
4 13 1523.48 20 14.76 2391 706 3.62 / 137.52 5 64
5 13 1073.96 20 14.84 1801 535 4.16 / 138.05 5 73
6 13 387.64 20 15.06 864 260 4.42 / 138.31 5 74
7 8 0.08 248 15.14 315 1183 5.60 / 139.49 5 139
Average= 5.17
(KJ/cycle)

Cycle 25 GMT 23/ 4/2021 17:39: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.40 38 15.15 456 263 0.26 / 128.56 5 17
2 7 2012.08 41 14.71 3036 1831 2.09 / 130.39 17 51
3 13 1916.56 20 14.72 2928 862 2.96 / 131.25 5 56
4 13 1390.92 20 14.79 2222 657 3.61 / 131.91 5 67
5 13 1056.20 20 14.85 1778 528 4.14 / 132.44 5 73
6 13 484.68 20 15.03 991 298 4.44 / 132.73 5 76
7 8 0.04 248 15.15 309 1161 5.60 / 133.90 5 141
Average= 5.15
(KJ/cycle)

Cycle 24 GMT 13/ 4/2021 20:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.32 37 15.15 447 251 0.25 / 123.14 5 18
2 7 2006.08 40 14.72 3027 1782 2.03 / 124.92 18 53
3 13 1809.00 20 14.74 2784 821 2.85 / 125.74 5 57
4 13 1411.32 20 14.79 2248 665 3.52 / 126.41 5 67
5 13 906.28 20 14.91 1566 467 3.99 / 126.88 5 75
6 13 363.64 20 15.08 829 250 4.24 / 127.13 5 70
7 8 0.08 246 15.15 314 1170 5.41 / 128.30 5 133
Average= 5.13
(KJ/cycle)

Cycle 23 GMT 3/ 4/2021 23:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.92 37 15.15 448 251 0.25 / 117.73 5 18
2 7 2009.76 40 14.73 3024 1782 2.03 / 119.51 18 52
3 13 1930.84 20 14.73 2921 861 2.89 / 120.37 5 55
4 13 1498.80 20 14.77 2364 698 3.59 / 121.07 5 64
5 13 977.16 20 14.90 1658 494 4.09 / 121.56 5 74
6 13 138.36 20 15.18 516 157 4.24 / 121.72 5 59
7 8 0.16 248 15.16 312 1173 5.42 / 122.89 5 190
Average= 5.12
(KJ/cycle)

Cycle 22 GMT 25/ 3/2021 1:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.12 37 15.16 453 254 0.25 / 112.21 5 17
2 7 2004.96 40 14.73 3025 1782 2.04 / 113.99 17 51
3 13 1913.04 20 14.74 2913 859 2.90 / 114.85 5 55
4 13 1611.04 20 14.76 2501 738 3.63 / 115.59 5 64
5 13 953.04 20 14.90 1631 486 4.12 / 116.08 5 74
6 13 305.84 20 15.12 743 225 4.34 / 116.30 5 69
7 8 -0.04 246 15.16 315 1175 5.52 / 117.47 5 137
Average= 5.11
(KJ/cycle)

Cycle 21 GMT 15/ 3/2021 4:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.04 37 15.16 446 250 0.25 / 106.81 5 17
2 7 2006.36 40 14.73 3035 1788 2.04 / 108.60 26 52
3 13 1909.60 20 14.74 2924 862 2.90 / 109.46 5 57
4 13 1468.68 20 14.80 2328 689 3.59 / 110.15 5 66
5 13 812.12 20 14.95 1448 433 4.02 / 110.58 5 77
6 13 273.84 20 15.13 708 214 4.24 / 110.80 5 67
7 8 0.12 246 15.17 310 1157 5.39 / 111.96 5 150
Average= 5.09
(KJ/cycle)

Cycle 20 GMT 5/ 3/2021 7:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.12 37 15.15 461 258 0.26 / 101.27 5 16
2 7 2006.48 40 14.74 3039 1792 2.05 / 103.06 16 50
3 13 1920.80 20 14.74 2928 863 2.91 / 103.93 5 56
4 13 1483.68 20 14.79 2350 695 3.61 / 104.62 5 65
5 13 826.20 20 14.95 1466 438 4.05 / 105.06 5 77
6 13 503.84 20 15.04 1028 309 4.36 / 105.37 5 77
7 8 0.04 246 15.16 320 1193 5.55 / 106.56 5 134
Average= 5.07
(KJ/cycle)

Cycle 19 GMT 23/ 2/2021 10:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.60 37 15.17 459 258 0.26 / 95.72 5 15
2 7 2012.72 40 14.74 3037 1791 2.05 / 97.51 15 52
3 13 1920.68 20 14.74 2929 863 2.91 / 98.38 5 57
4 13 1403.48 20 14.81 2230 661 3.57 / 99.04 5 67
5 13 1084.80 20 14.87 1800 535 4.11 / 99.57 5 73
6 13 311.72 20 15.12 759 230 4.34 / 99.80 5 69
7 13 18.16 20 15.21 348 106 4.44 / 99.91 5 58
8 8 -0.04 227 15.16 321 1105 5.55 / 101.01 5 141
Average= 5.05
(KJ/cycle)

Cycle 18 GMT 13/ 2/2021 13:25: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.20 37 15.16 447 251 0.25 / 90.33 5 16
2 7 2013.20 40 14.75 3039 1793 2.04 / 92.12 16 53
3 13 1725.12 20 14.79 2676 792 2.84 / 92.91 5 60
4 13 1427.84 20 14.81 2274 674 3.51 / 93.59 5 67
5 13 978.88 20 14.91 1670 498 4.01 / 94.09 5 75
6 13 205.00 20 15.16 607 184 4.19 / 94.27 5 66
7 13 43.16 20 15.21 382 116 4.31 / 94.39 5 60
8 8 0.04 225 15.17 316 1079 5.39 / 95.47 5 139
Average= 5.02
(KJ/cycle)

Cycle 17 GMT 3/ 2/2021 16: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.56 37 15.17 449 252 0.25 / 84.61 5 17
2 7 2007.40 40 14.75 3035 1791 2.04 / 86.40 17 53
3 13 1926.08 20 14.74 2938 866 2.91 / 87.27 5 56
4 13 1509.68 20 14.80 2387 707 3.62 / 87.98 5 65
5 13 1169.36 20 14.85 1921 571 4.19 / 88.55 5 72
6 13 591.36 20 15.02 1144 344 4.53 / 88.89 5 80
7 8 0.04 248 15.17 316 1189 5.72 / 90.08 5 138
Average= 5.00
(KJ/cycle)

Cycle 16 GMT 24/ 1/2021 19:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.24 37 15.17 455 255 0.26 / 79.10 5 17
2 7 2012.88 40 14.75 3043 1795 2.05 / 80.89 17 53
3 13 1922.04 20 14.76 2929 865 2.92 / 81.76 5 57
4 13 1501.96 20 14.81 2360 699 3.61 / 82.46 5 66
5 13 1051.96 20 14.90 1765 526 4.14 / 82.98 5 74
6 13 185.88 20 15.18 584 177 4.32 / 83.16 5 64
7 13 33.68 20 15.22 369 112 4.43 / 83.27 5 59
8 8 0.00 227 15.17 316 1088 5.52 / 84.36 5 139
Average= 4.96
(KJ/cycle)

Cycle 15 GMT 14/ 1/2021 22: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.28 37 15.18 447 251 0.25 / 73.52 5 17
2 7 2013.84 41 14.75 3046 1842 2.09 / 75.36 17 52
3 13 1917.68 20 14.75 2933 865 2.96 / 76.22 5 57
4 13 1591.40 20 14.79 2490 737 3.69 / 76.96 5 63
5 13 1026.00 20 14.90 1731 516 4.21 / 77.48 5 74
6 13 236.52 20 15.16 649 197 4.41 / 77.67 5 67
7 8 -0.04 246 15.18 313 1169 5.58 / 78.84 5 135
Average= 4.93
(KJ/cycle)

Cycle 14 GMT 5/ 1/2021 0:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.88 37 15.18 454 255 0.25 / 68.15 5 19
2 7 2005.48 40 14.76 3032 1790 2.05 / 69.94 19 52
3 13 1908.56 20 14.76 2920 862 2.91 / 70.80 5 56
4 13 1399.96 20 14.84 2237 664 3.57 / 71.46 5 67
5 13 963.68 20 14.93 1652 493 4.06 / 71.96 5 75
6 13 113.00 20 15.21 483 147 4.21 / 72.10 5 59
7 8 0.12 244 15.19 314 1164 5.38 / 73.27 5 131
Average= 4.88
(KJ/cycle)

Cycle 13 GMT 26/12/2020 3:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.60 37 15.18 454 255 0.25 / 62.68 5 23
2 7 2011.52 40 14.77 3040 1796 2.05 / 64.47 31 52
3 13 1921.40 20 14.77 2926 864 2.92 / 65.34 5 56
4 13 1612.28 20 14.79 2516 744 3.66 / 66.08 5 63
5 13 867.08 20 14.97 1518 454 4.11 / 66.53 5 77
6 13 212.68 20 15.18 605 184 4.30 / 66.72 5 65
7 8 0.00 246 15.19 314 1173 5.47 / 67.89 5 147
Average= 4.85
(KJ/cycle)

Cycle 12 GMT 16/12/2020 6: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.36 37 15.18 453 254 0.25 / 57.24 5 25
2 7 2005.28 40 14.78 3031 1792 2.05 / 59.03 25 53
3 13 1914.04 20 14.78 2925 865 2.91 / 59.90 5 57
4 13 1473.60 20 14.83 2329 691 3.60 / 60.59 5 66
5 13 931.92 20 14.95 1605 480 4.08 / 61.07 5 76
6 13 185.32 20 15.20 571 174 4.26 / 61.24 5 63
7 8 0.12 246 15.19 315 1177 5.43 / 62.42 5 136
Average= 4.80
(KJ/cycle)

Cycle 11 GMT 6/12/2020 9: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.36 37 15.17 471 264 0.26 / 51.67 5 27
2 7 2007.32 40 14.78 3048 1802 2.07 / 53.47 27 54
3 13 1919.12 20 14.78 2921 863 2.93 / 54.34 5 57
4 13 1503.76 20 14.83 2374 704 3.63 / 55.04 5 65
5 13 1057.20 20 14.91 1778 530 4.16 / 55.57 5 74
6 13 266.80 20 15.16 697 211 4.38 / 55.78 5 68
7 8 0.08 246 15.19 323 1207 5.58 / 56.99 5 137
Average= 4.75
(KJ/cycle)

Cycle 10 GMT 26/11/2020 11:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.84 37 15.18 465 261 0.26 / 46.25 5 23
2 7 2013.20 40 14.78 3047 1801 2.06 / 48.05 23 53
3 13 1920.36 20 14.78 2931 866 2.93 / 48.91 5 57
4 13 1504.00 20 14.82 2386 707 3.64 / 49.62 5 67
5 13 850.96 20 14.97 1507 451 4.09 / 50.07 5 77
6 13 122.84 20 15.21 498 151 4.24 / 50.22 5 64
7 8 0.08 244 15.19 319 1182 5.42 / 51.41 5 133
Average= 4.67
(KJ/cycle)

Cycle 9 GMT 16/11/2020 14:26: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.92 37 15.19 454 255 0.26 / 40.77 5 29
2 7 2010.44 40 14.78 3031 1792 2.05 / 42.56 29 52
3 13 1927.56 20 14.79 2938 869 2.92 / 43.43 5 57
4 13 1500.32 20 14.83 2365 701 3.62 / 44.13 5 66
5 13 961.60 20 14.94 1649 493 4.11 / 44.62 5 76
6 13 198.24 20 15.19 603 183 4.29 / 44.81 5 68
7 8 0.16 244 15.19 318 1179 5.47 / 45.98 5 134
Average= 4.60
(KJ/cycle)

Cycle 8 GMT 6/11/2020 17: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.24 36 15.19 464 254 0.25 / 35.34 5 29
2 7 2004.16 40 14.79 3028 1791 2.05 / 37.14 29 54
3 13 1919.36 20 14.79 2921 864 2.91 / 38.00 5 57
4 13 1505.04 20 14.84 2374 705 3.61 / 38.70 5 65
5 13 942.44 20 14.95 1617 483 4.10 / 39.19 5 76
6 13 165.40 20 15.21 549 167 4.26 / 39.36 5 64
7 8 0.00 244 15.20 312 1157 5.42 / 40.51 5 136
Average= 4.50
(KJ/cycle)

Cycle 7 GMT 27/10/2020 20: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.92 36 15.18 464 254 0.25 / 30.02 5 30
2 7 2006.32 40 14.79 3040 1798 2.05 / 31.82 27 52
3 13 1809.80 20 14.81 2786 825 2.88 / 32.65 5 60
4 13 1296.88 20 14.89 2096 624 3.50 / 33.27 5 69
5 13 987.00 20 14.94 1674 500 4.00 / 33.77 5 75
6 13 121.80 20 15.22 497 151 4.15 / 33.92 5 63
7 8 -0.04 244 15.20 315 1168 5.32 / 35.09 5 139
Average= 4.39
(KJ/cycle)

Cycle 6 GMT 17/10/2020 22:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.04 35 15.19 469 249 0.25 / 24.57 5 31
2 3 1038.16 1 15.20 1737 26 0.28 / 24.59 5 57
3 7 2012.76 40 14.80 3030 1794 2.07 / 26.39 57 53
4 13 1921.16 20 14.80 2923 865 2.93 / 27.25 5 58
5 13 1488.12 20 14.84 2351 698 3.63 / 27.95 5 66
6 13 845.12 20 14.99 1482 444 4.08 / 28.40 5 77
7 13 213.44 20 15.19 622 189 4.27 / 28.58 5 67
8 8 0.00 246 15.20 317 1185 5.45 / 29.77 5 133
Average= 4.25
(KJ/cycle)

Cycle 5 GMT 8/10/2020 1: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.88 31 15.19 466 219 0.22 / 19.02 5 32
2 10 1003.80 4 15.14 1674 101 0.32 / 19.12 5 50
3 3 1057.32 1 15.17 1797 27 0.35 / 19.15 5 62
4 7 2012.32 40 14.80 3054 1808 2.16 / 20.95 62 53
5 13 1921.04 20 14.81 2932 868 3.02 / 21.82 5 57
6 13 1503.80 20 14.85 2382 707 3.73 / 22.53 5 67
7 13 868.36 20 14.98 1523 456 4.19 / 22.99 5 77
8 13 122.36 20 15.22 494 150 4.34 / 23.14 5 65
9 8 0.12 246 15.20 316 1182 5.52 / 24.32 5 131
Average= 4.05
(KJ/cycle)

Cycle 4 GMT 28/ 9/2020 3:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.52 36 15.19 471 258 0.26 / 14.31 5 32
2 7 1516.68 41 14.96 2382 1461 1.72 / 15.77 32 58
3 13 1447.40 20 14.97 2281 683 2.40 / 16.46 5 63
4 13 1259.72 20 14.96 2034 609 3.01 / 17.07 5 68
5 13 837.56 20 15.03 1479 445 3.45 / 17.51 5 77
6 13 73.28 20 15.25 428 131 3.59 / 17.64 5 64
7 8 0.12 240 15.22 317 1158 4.74 / 18.80 5 131
Average= 3.76
(KJ/cycle)

Cycle 3 GMT 26/ 9/2020 17:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.48 35 15.19 471 250 0.25 / 9.60 5 30
2 3 1024.68 1 15.23 1738 26 0.28 / 9.63 5 60
3 7 1512.96 41 14.96 2385 1463 1.74 / 11.09 60 60
4 13 1444.80 20 14.96 2283 683 2.42 / 11.78 5 62
5 13 1255.00 20 14.95 2037 609 3.03 / 12.39 5 68
6 13 734.28 20 15.06 1335 402 3.43 / 12.79 5 77
7 8 0.08 261 15.22 319 1267 4.70 / 14.06 5 135
Average= 3.51
(KJ/cycle)

Cycle 2 GMT 25/ 9/2020 7:14:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.20 31 15.21 462 218 0.22 / 4.84 5 30
2 10 1008.56 4 15.15 1686 102 0.32 / 4.94 5 48
3 3 1050.16 1 15.19 1772 27 0.35 / 4.97 5 63
4 7 1513.52 41 14.96 2363 1449 1.80 / 6.42 63 58
5 13 1442.12 20 14.96 2275 681 2.48 / 7.10 5 61
6 13 1238.40 20 14.96 2000 598 3.08 / 7.70 5 67
7 13 581.16 20 15.11 1116 337 3.41 / 8.03 5 76
8 13 135.24 20 15.23 515 157 3.57 / 8.19 5 65
9 8 0.20 240 15.21 319 1164 4.73 / 9.35 5 140
Average= 3.12
(KJ/cycle)

Cycle 1 GMT 23/ 9/2020 21:10: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.56 31 15.37 436 208 0.21 / 1.94 5 23
2 10 1006.04 3 15.17 1706 78 0.29 / 2.01 5 49
3 3 1069.68 2 15.17 1798 55 0.34 / 2.07 5 62
4 7 1010.88 40 15.07 1705 1028 1.37 / 3.10 62 69
5 13 488.32 20 15.18 993 301 1.67 / 3.40 5 75
6 8 0.04 253 15.25 317 1223 2.89 / 4.62 5 130
Average= 2.31
(KJ/cycle)

Cycle 0 GMT 23/ 9/2020 10:26:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 90.12 30 15.54 430 200 0.20 / 0.20 5 29
2 7 100.44 40 15.52 437 271 0.47 / 0.47 29 29
3 13 61.36 20 15.51 380 118 0.59 / 0.59 5 32
4 8 0.16 253 15.46 291 1138 1.73 / 1.73 5 165
Average= 1.73
(KJ/cycle)