SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.76 | 34 | 14.93 | 466 | 237 | 0.24 / 626.39 | 2 | 2 |
2 | 7 | 2010.44 | 31 | 14.72 | 2854 | 1302 | 1.54 / 627.70 | 2 | 2 |
3 | 13 | 1609.68 | 20 | 14.72 | 2391 | 704 | 2.24 / 628.40 | 2 | 3 |
4 | 13 | 1062.28 | 20 | 14.77 | 1719 | 508 | 2.75 / 628.91 | 2 | 4 |
5 | 13 | 365.40 | 20 | 14.94 | 796 | 238 | 2.99 / 629.14 | 2 | 2 |
6 | 8 | 0.12 | 165 | 15.00 | 299 | 740 | 3.73 / 629.88 | 2 | 4 |
7 | 14 | 0.12 | 30 | 14.97 | 305 | 137 | 3.87 / 630.02 | 2 | 8 |
Average= | 3.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.52 | 34 | 14.93 | 468 | 238 | 0.24 / 622.57 | 2 | 2 |
2 | 7 | 2002.92 | 31 | 14.73 | 2854 | 1303 | 1.54 / 623.88 | 2 | 2 |
3 | 13 | 1616.04 | 20 | 14.72 | 2392 | 704 | 2.24 / 624.58 | 2 | 3 |
4 | 13 | 1192.76 | 20 | 14.75 | 1883 | 555 | 2.80 / 625.13 | 2 | 5 |
5 | 13 | 458.48 | 20 | 14.92 | 928 | 277 | 3.08 / 625.41 | 2 | 3 |
6 | 8 | 0.04 | 165 | 14.99 | 301 | 744 | 3.82 / 626.16 | 2 | 2 |
Average= | 3.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.20 | 34 | 14.93 | 455 | 231 | 0.23 / 618.74 | 2 | 2 |
2 | 7 | 2007.76 | 31 | 14.73 | 2857 | 1305 | 1.54 / 620.04 | 2 | 2 |
3 | 13 | 1746.44 | 20 | 14.69 | 2548 | 749 | 2.28 / 620.79 | 2 | 2 |
4 | 13 | 1164.20 | 20 | 14.75 | 1841 | 543 | 2.83 / 621.34 | 2 | 3 |
5 | 13 | 437.84 | 20 | 14.92 | 896 | 267 | 3.09 / 621.60 | 2 | 2 |
6 | 8 | 0.04 | 165 | 14.99 | 296 | 732 | 3.83 / 622.33 | 2 | 4 |
Average= | 3.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.40 | 33 | 14.95 | 451 | 223 | 0.22 / 614.87 | 2 | 2 |
2 | 7 | 2012.36 | 31 | 14.74 | 2857 | 1305 | 1.53 / 616.17 | 2 | 2 |
3 | 13 | 1736.12 | 20 | 14.71 | 2525 | 743 | 2.27 / 616.92 | 2 | 2 |
4 | 13 | 1161.00 | 20 | 14.75 | 1834 | 541 | 2.81 / 617.46 | 2 | 4 |
5 | 13 | 577.00 | 20 | 14.88 | 1082 | 322 | 3.13 / 617.78 | 2 | 3 |
6 | 8 | -0.08 | 165 | 14.99 | 295 | 730 | 3.86 / 618.51 | 2 | 2 |
Average= | 3.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.52 | 34 | 14.96 | 459 | 233 | 0.23 / 611.16 | 2 | 2 |
2 | 7 | 2008.92 | 31 | 14.74 | 2856 | 1305 | 1.54 / 612.46 | 2 | 2 |
3 | 13 | 1617.24 | 20 | 14.73 | 2397 | 706 | 2.24 / 613.17 | 2 | 2 |
4 | 13 | 1065.80 | 20 | 14.79 | 1714 | 507 | 2.75 / 613.67 | 2 | 3 |
5 | 13 | 366.76 | 20 | 14.96 | 800 | 239 | 2.99 / 613.91 | 2 | 2 |
6 | 8 | 0.24 | 165 | 15.00 | 295 | 730 | 3.72 / 614.64 | 2 | 5 |
Average= | 3.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.68 | 34 | 14.94 | 450 | 229 | 0.23 / 607.30 | 2 | 2 |
2 | 7 | 2011.28 | 31 | 14.72 | 2859 | 1305 | 1.53 / 608.61 | 2 | 2 |
3 | 13 | 1620.40 | 20 | 14.72 | 2407 | 709 | 2.24 / 609.32 | 2 | 2 |
4 | 13 | 1186.52 | 20 | 14.76 | 1871 | 552 | 2.79 / 609.87 | 2 | 5 |
5 | 13 | 586.16 | 20 | 14.88 | 1091 | 325 | 3.12 / 610.19 | 2 | 4 |
6 | 8 | 0.16 | 165 | 15.02 | 295 | 731 | 3.85 / 610.92 | 2 | 3 |
Average= | 3.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.88 | 34 | 14.93 | 460 | 234 | 0.23 / 603.30 | 2 | 2 |
2 | 7 | 2003.92 | 31 | 14.72 | 2856 | 1303 | 1.54 / 604.61 | 2 | 2 |
3 | 13 | 1739.68 | 20 | 14.71 | 2552 | 751 | 2.29 / 605.36 | 2 | 3 |
4 | 13 | 1154.04 | 20 | 14.76 | 1837 | 542 | 2.83 / 605.90 | 2 | 5 |
5 | 13 | 560.04 | 20 | 14.89 | 1062 | 316 | 3.15 / 606.22 | 2 | 3 |
6 | 8 | 0.08 | 165 | 14.99 | 293 | 725 | 3.87 / 606.94 | 2 | 7 |
7 | 14 | 0.08 | 30 | 14.97 | 297 | 133 | 4.00 / 607.07 | 2 | 2 |
Average= | 3.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.36 | 34 | 14.94 | 457 | 232 | 0.23 / 599.40 | 2 | 2 |
2 | 7 | 2007.84 | 31 | 14.72 | 2860 | 1305 | 1.54 / 600.70 | 2 | 2 |
3 | 13 | 1612.84 | 20 | 14.73 | 2399 | 707 | 2.24 / 601.41 | 2 | 2 |
4 | 13 | 1060.32 | 20 | 14.79 | 1708 | 505 | 2.75 / 601.92 | 2 | 2 |
5 | 13 | 479.56 | 20 | 14.92 | 952 | 284 | 3.03 / 602.20 | 2 | 2 |
6 | 8 | -0.12 | 165 | 15.00 | 297 | 735 | 3.77 / 602.93 | 2 | 6 |
7 | 14 | -0.12 | 30 | 14.98 | 300 | 135 | 3.90 / 603.07 | 2 | 2 |
Average= | 3.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.24 | 34 | 14.93 | 453 | 230 | 0.23 / 595.55 | 2 | 2 |
2 | 7 | 2013.08 | 32 | 14.73 | 2856 | 1346 | 1.58 / 596.90 | 2 | 2 |
3 | 13 | 1739.00 | 20 | 14.71 | 2540 | 747 | 2.32 / 597.64 | 2 | 3 |
4 | 13 | 1151.00 | 20 | 14.77 | 1817 | 537 | 2.86 / 598.18 | 2 | 4 |
5 | 13 | 439.12 | 20 | 14.93 | 885 | 264 | 3.12 / 598.45 | 2 | 2 |
6 | 8 | 0.04 | 165 | 15.00 | 291 | 720 | 3.84 / 599.17 | 2 | 5 |
Average= | 3.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.12 | 34 | 14.91 | 448 | 227 | 0.23 / 591.61 | 2 | 2 |
2 | 7 | 2010.16 | 31 | 14.74 | 2845 | 1300 | 1.53 / 592.91 | 2 | 2 |
3 | 13 | 1626.96 | 20 | 14.73 | 2406 | 709 | 2.24 / 593.62 | 2 | 2 |
4 | 13 | 1080.24 | 20 | 14.79 | 1724 | 510 | 2.75 / 594.13 | 2 | 4 |
5 | 13 | 636.20 | 20 | 14.88 | 1143 | 340 | 3.09 / 594.47 | 2 | 3 |
6 | 8 | 0.16 | 165 | 15.00 | 291 | 720 | 3.81 / 595.19 | 2 | 3 |
7 | 14 | 0.16 | 30 | 14.97 | 294 | 132 | 3.94 / 595.32 | 2 | 3 |
Average= | 3.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.12 | 34 | 14.93 | 448 | 227 | 0.23 / 587.75 | 2 | 2 |
2 | 3 | 1017.36 | 1 | 15.12 | 1678 | 25 | 0.25 / 587.78 | 2 | 2 |
3 | 7 | 2013.08 | 31 | 14.73 | 2855 | 1304 | 1.56 / 589.08 | 2 | 2 |
4 | 13 | 1628.48 | 20 | 14.73 | 2392 | 705 | 2.26 / 589.79 | 2 | 2 |
5 | 13 | 1214.76 | 20 | 14.76 | 1889 | 558 | 2.82 / 590.34 | 2 | 3 |
6 | 13 | 616.52 | 20 | 14.87 | 1120 | 333 | 3.15 / 590.68 | 2 | 3 |
7 | 8 | 0.04 | 165 | 14.98 | 286 | 707 | 3.86 / 591.38 | 2 | 4 |
Average= | 3.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.08 | 33 | 14.95 | 438 | 216 | 0.22 / 583.84 | 2 | 2 |
2 | 7 | 2019.60 | 31 | 14.73 | 2866 | 1309 | 1.52 / 585.15 | 2 | 2 |
3 | 13 | 1651.80 | 20 | 14.72 | 2430 | 715 | 2.24 / 585.87 | 2 | 2 |
4 | 13 | 1107.20 | 20 | 14.77 | 1756 | 519 | 2.76 / 586.38 | 2 | 3 |
5 | 13 | 516.36 | 20 | 14.89 | 984 | 293 | 3.05 / 586.68 | 2 | 3 |
6 | 13 | 93.76 | 20 | 14.99 | 433 | 130 | 3.18 / 586.81 | 2 | 3 |
7 | 8 | 0.28 | 165 | 14.98 | 290 | 717 | 3.90 / 587.52 | 2 | 5 |
Average= | 3.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.08 | 34 | 14.95 | 446 | 227 | 0.23 / 579.98 | 2 | 2 |
2 | 7 | 2007.92 | 31 | 14.75 | 2858 | 1307 | 1.53 / 581.28 | 2 | 2 |
3 | 13 | 1736.80 | 20 | 14.72 | 2532 | 745 | 2.28 / 582.03 | 2 | 2 |
4 | 13 | 1292.88 | 20 | 14.74 | 2000 | 590 | 2.87 / 582.62 | 2 | 3 |
5 | 13 | 539.56 | 20 | 14.91 | 1027 | 306 | 3.17 / 582.93 | 2 | 3 |
6 | 8 | 0.20 | 165 | 15.00 | 283 | 700 | 3.88 / 583.63 | 2 | 4 |
Average= | 3.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.80 | 34 | 14.93 | 462 | 235 | 0.23 / 575.95 | 2 | 2 |
2 | 7 | 2009.96 | 32 | 14.75 | 2863 | 1351 | 1.59 / 577.30 | 2 | 2 |
3 | 13 | 1732.92 | 20 | 14.73 | 2550 | 751 | 2.34 / 578.05 | 2 | 2 |
4 | 13 | 1163.44 | 20 | 14.78 | 1841 | 544 | 2.88 / 578.60 | 2 | 2 |
5 | 13 | 550.40 | 20 | 14.91 | 1041 | 310 | 3.19 / 578.91 | 2 | 3 |
6 | 8 | 0.08 | 165 | 15.00 | 288 | 713 | 3.90 / 579.62 | 2 | 2 |
7 | 14 | 0.08 | 30 | 14.98 | 285 | 128 | 4.03 / 579.75 | 2 | 6 |
Average= | 3.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.44 | 34 | 14.92 | 466 | 236 | 0.24 / 572.24 | 2 | 2 |
2 | 7 | 2007.80 | 31 | 14.75 | 2857 | 1306 | 1.54 / 573.54 | 2 | 2 |
3 | 13 | 1621.20 | 20 | 14.73 | 2407 | 709 | 2.25 / 574.25 | 2 | 2 |
4 | 13 | 1079.04 | 20 | 14.77 | 1736 | 513 | 2.76 / 574.76 | 2 | 3 |
5 | 13 | 374.52 | 20 | 14.94 | 797 | 238 | 3.00 / 575.00 | 2 | 2 |
6 | 8 | 0.16 | 165 | 14.99 | 289 | 715 | 3.72 / 575.72 | 2 | 4 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.32 | 34 | 14.94 | 452 | 230 | 0.23 / 568.23 | 2 | 2 |
2 | 7 | 2012.88 | 31 | 14.73 | 2859 | 1306 | 1.54 / 569.54 | 2 | 2 |
3 | 13 | 1616.44 | 20 | 14.73 | 2389 | 704 | 2.24 / 570.24 | 2 | 3 |
4 | 13 | 1185.32 | 20 | 14.76 | 1860 | 549 | 2.79 / 570.79 | 2 | 3 |
5 | 13 | 570.32 | 20 | 14.89 | 1070 | 319 | 3.11 / 571.11 | 2 | 3 |
6 | 13 | 114.20 | 20 | 14.98 | 478 | 143 | 3.25 / 571.25 | 2 | 2 |
7 | 8 | 0.04 | 165 | 14.97 | 302 | 746 | 4.00 / 572.00 | 2 | 2 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.32 | 34 | 14.94 | 456 | 232 | 0.23 / 564.49 | 2 | 2 |
2 | 7 | 2002.36 | 31 | 14.75 | 2835 | 1296 | 1.53 / 565.79 | 2 | 2 |
3 | 13 | 1601.60 | 20 | 14.74 | 2376 | 700 | 2.23 / 566.49 | 2 | 3 |
4 | 13 | 1175.16 | 20 | 14.77 | 1838 | 543 | 2.77 / 567.03 | 2 | 3 |
5 | 13 | 429.92 | 20 | 14.93 | 873 | 261 | 3.03 / 567.29 | 2 | 2 |
6 | 8 | 0.04 | 165 | 14.99 | 287 | 710 | 3.74 / 568.00 | 2 | 4 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.36 | 34 | 14.93 | 450 | 228 | 0.23 / 560.60 | 2 | 2 |
2 | 7 | 2003.76 | 31 | 14.74 | 2841 | 1298 | 1.53 / 561.90 | 2 | 2 |
3 | 13 | 1736.92 | 20 | 14.72 | 2533 | 746 | 2.27 / 562.65 | 2 | 2 |
4 | 13 | 1130.64 | 20 | 14.77 | 1788 | 528 | 2.80 / 563.18 | 2 | 2 |
5 | 13 | 410.20 | 20 | 14.93 | 838 | 250 | 3.05 / 563.43 | 2 | 3 |
6 | 8 | 0.12 | 165 | 15.00 | 286 | 708 | 3.76 / 564.13 | 2 | 4 |
7 | 14 | 0.12 | 30 | 14.98 | 286 | 129 | 3.89 / 564.26 | 2 | 4 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.24 | 34 | 14.94 | 451 | 229 | 0.23 / 556.86 | 2 | 2 |
2 | 7 | 2008.40 | 31 | 14.75 | 2854 | 1305 | 1.53 / 558.16 | 2 | 2 |
3 | 13 | 1628.48 | 20 | 14.73 | 2411 | 710 | 2.24 / 558.87 | 2 | 3 |
4 | 13 | 1082.48 | 20 | 14.79 | 1724 | 510 | 2.75 / 559.38 | 2 | 4 |
5 | 13 | 481.56 | 20 | 14.92 | 946 | 282 | 3.04 / 559.67 | 2 | 2 |
6 | 8 | 0.24 | 165 | 15.00 | 287 | 710 | 3.75 / 560.38 | 2 | 4 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.32 | 34 | 14.94 | 454 | 231 | 0.23 / 552.99 | 2 | 2 |
2 | 7 | 2008.68 | 31 | 14.73 | 2842 | 1298 | 1.53 / 554.29 | 2 | 2 |
3 | 13 | 1603.76 | 20 | 14.73 | 2377 | 700 | 2.23 / 554.99 | 2 | 3 |
4 | 13 | 1040.84 | 20 | 14.79 | 1674 | 495 | 2.72 / 555.48 | 2 | 4 |
5 | 13 | 317.60 | 20 | 14.96 | 723 | 216 | 2.94 / 555.70 | 2 | 2 |
6 | 13 | 37.08 | 20 | 15.02 | 341 | 102 | 3.04 / 555.80 | 2 | 3 |
7 | 8 | -0.04 | 165 | 14.98 | 284 | 702 | 3.74 / 556.50 | 2 | 5 |
8 | 14 | -0.04 | 30 | 14.96 | 283 | 127 | 3.87 / 556.63 | 2 | 3 |
Average= | 3.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.48 | 34 | 14.94 | 448 | 228 | 0.23 / 549.05 | 2 | 2 |
2 | 7 | 2004.12 | 31 | 14.74 | 2843 | 1299 | 1.53 / 550.34 | 2 | 2 |
3 | 13 | 1741.96 | 20 | 14.70 | 2550 | 750 | 2.28 / 551.09 | 2 | 3 |
4 | 13 | 1305.96 | 20 | 14.72 | 2011 | 592 | 2.87 / 551.69 | 2 | 2 |
5 | 13 | 671.72 | 20 | 14.87 | 1195 | 355 | 3.22 / 552.04 | 2 | 4 |
6 | 8 | 0.04 | 165 | 15.00 | 289 | 715 | 3.94 / 552.76 | 2 | 3 |
Average= | 3.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.44 | 34 | 14.93 | 459 | 233 | 0.23 / 545.10 | 2 | 2 |
2 | 7 | 2003.72 | 31 | 14.75 | 2849 | 1303 | 1.54 / 546.41 | 2 | 2 |
3 | 13 | 1747.88 | 20 | 14.71 | 2555 | 752 | 2.29 / 547.16 | 2 | 2 |
4 | 13 | 1164.32 | 20 | 14.76 | 1839 | 543 | 2.83 / 547.70 | 2 | 2 |
5 | 13 | 429.32 | 20 | 14.93 | 879 | 262 | 3.09 / 547.96 | 2 | 2 |
6 | 8 | 0.16 | 165 | 14.99 | 292 | 722 | 3.81 / 548.69 | 2 | 2 |
7 | 14 | 0.16 | 30 | 14.97 | 295 | 132 | 3.95 / 548.82 | 2 | 3 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.92 | 34 | 14.93 | 459 | 233 | 0.23 / 541.25 | 2 | 2 |
2 | 7 | 2007.72 | 31 | 14.76 | 2852 | 1305 | 1.54 / 542.56 | 2 | 2 |
3 | 13 | 1604.36 | 20 | 14.74 | 2386 | 703 | 2.24 / 543.26 | 2 | 2 |
4 | 13 | 1189.00 | 20 | 14.76 | 1868 | 551 | 2.79 / 543.81 | 2 | 3 |
5 | 13 | 584.60 | 20 | 14.90 | 1087 | 324 | 3.12 / 544.14 | 2 | 3 |
6 | 8 | 0.12 | 165 | 15.00 | 297 | 735 | 3.85 / 544.87 | 2 | 3 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.36 | 34 | 14.95 | 453 | 230 | 0.23 / 537.33 | 2 | 2 |
2 | 7 | 2008.88 | 32 | 14.74 | 2836 | 1338 | 1.57 / 538.66 | 2 | 2 |
3 | 13 | 1738.24 | 20 | 14.72 | 2545 | 749 | 2.32 / 539.41 | 2 | 2 |
4 | 13 | 1044.68 | 20 | 14.81 | 1666 | 493 | 2.81 / 539.91 | 2 | 4 |
5 | 13 | 460.20 | 20 | 14.93 | 914 | 273 | 3.08 / 540.18 | 2 | 2 |
6 | 13 | 59.40 | 20 | 15.01 | 383 | 115 | 3.20 / 540.29 | 2 | 3 |
7 | 8 | 0.08 | 165 | 14.98 | 293 | 724 | 3.92 / 541.02 | 2 | 3 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.44 | 34 | 14.94 | 455 | 231 | 0.23 / 533.47 | 2 | 2 |
2 | 7 | 2005.92 | 31 | 14.75 | 2825 | 1292 | 1.52 / 534.76 | 2 | 2 |
3 | 13 | 1742.56 | 20 | 14.71 | 2524 | 743 | 2.27 / 535.51 | 2 | 2 |
4 | 13 | 1189.00 | 20 | 14.76 | 1853 | 547 | 2.81 / 536.05 | 2 | 3 |
5 | 13 | 476.20 | 20 | 14.92 | 936 | 279 | 3.09 / 536.33 | 2 | 2 |
6 | 13 | 17.08 | 20 | 15.03 | 295 | 89 | 3.18 / 536.42 | 2 | 2 |
7 | 8 | 0.12 | 165 | 14.99 | 273 | 675 | 3.86 / 537.10 | 2 | 4 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.24 | 34 | 14.93 | 441 | 224 | 0.22 / 529.63 | 2 | 2 |
2 | 7 | 2004.44 | 31 | 14.73 | 2843 | 1298 | 1.52 / 530.93 | 2 | 2 |
3 | 13 | 1615.00 | 20 | 14.73 | 2395 | 706 | 2.23 / 531.63 | 2 | 2 |
4 | 13 | 1059.92 | 20 | 14.78 | 1707 | 505 | 2.73 / 532.14 | 2 | 4 |
5 | 13 | 465.56 | 20 | 14.92 | 933 | 278 | 3.01 / 532.41 | 2 | 3 |
6 | 13 | 30.12 | 20 | 15.02 | 336 | 101 | 3.11 / 532.52 | 2 | 2 |
7 | 8 | 0.00 | 165 | 14.99 | 293 | 725 | 3.84 / 533.24 | 2 | 2 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.60 | 34 | 14.95 | 451 | 229 | 0.23 / 525.57 | 2 | 2 |
2 | 7 | 2007.44 | 31 | 14.73 | 2851 | 1302 | 1.53 / 526.87 | 2 | 2 |
3 | 13 | 1615.80 | 20 | 14.72 | 2406 | 708 | 2.24 / 527.58 | 2 | 3 |
4 | 13 | 1054.64 | 20 | 14.79 | 1702 | 503 | 2.74 / 528.09 | 2 | 4 |
5 | 13 | 612.84 | 20 | 14.88 | 1133 | 337 | 3.08 / 528.42 | 2 | 2 |
6 | 13 | 49.16 | 20 | 15.02 | 374 | 112 | 3.19 / 528.54 | 2 | 2 |
7 | 8 | 0.04 | 165 | 14.98 | 297 | 734 | 3.93 / 529.27 | 2 | 3 |
8 | 14 | 0.04 | 30 | 14.96 | 298 | 134 | 4.06 / 529.40 | 3 | 6 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.00 | 34 | 14.95 | 465 | 236 | 0.24 / 521.62 | 2 | 2 |
2 | 7 | 2010.12 | 31 | 14.74 | 2862 | 1308 | 1.54 / 522.93 | 2 | 2 |
3 | 13 | 1619.16 | 20 | 14.72 | 2417 | 712 | 2.26 / 523.64 | 2 | 2 |
4 | 13 | 1179.44 | 20 | 14.77 | 1852 | 547 | 2.80 / 524.19 | 2 | 3 |
5 | 13 | 586.76 | 20 | 14.90 | 1095 | 326 | 3.13 / 524.51 | 2 | 3 |
6 | 13 | 22.08 | 20 | 15.04 | 324 | 97 | 3.23 / 524.61 | 2 | 2 |
7 | 8 | 0.04 | 165 | 15.00 | 296 | 733 | 3.96 / 525.34 | 2 | 3 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.48 | 33 | 14.94 | 456 | 225 | 0.22 / 517.72 | 2 | 2 |
2 | 7 | 2005.44 | 31 | 14.73 | 2840 | 1297 | 1.52 / 519.02 | 2 | 2 |
3 | 13 | 1743.04 | 20 | 14.71 | 2547 | 749 | 2.27 / 519.77 | 2 | 2 |
4 | 13 | 1143.72 | 20 | 14.77 | 1814 | 536 | 2.81 / 520.31 | 2 | 3 |
5 | 13 | 408.96 | 20 | 14.95 | 853 | 255 | 3.06 / 520.56 | 2 | 2 |
6 | 13 | 25.84 | 20 | 15.04 | 328 | 99 | 3.16 / 520.66 | 2 | 2 |
7 | 8 | 0.04 | 165 | 15.00 | 293 | 725 | 3.89 / 521.38 | 2 | 4 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.64 | 33 | 14.95 | 460 | 227 | 0.23 / 513.75 | 2 | 2 |
2 | 7 | 2012.08 | 31 | 14.75 | 2860 | 1308 | 1.53 / 515.06 | 2 | 2 |
3 | 13 | 1740.00 | 20 | 14.72 | 2543 | 749 | 2.28 / 515.81 | 2 | 3 |
4 | 13 | 1040.68 | 20 | 14.81 | 1684 | 499 | 2.78 / 516.31 | 2 | 5 |
5 | 13 | 599.76 | 20 | 14.89 | 1116 | 332 | 3.11 / 516.64 | 2 | 2 |
6 | 13 | 48.64 | 20 | 15.03 | 373 | 112 | 3.23 / 516.75 | 2 | 2 |
7 | 8 | 0.16 | 165 | 15.00 | 301 | 745 | 3.97 / 517.50 | 2 | 5 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.96 | 33 | 14.94 | 472 | 233 | 0.23 / 509.65 | 2 | 2 |
2 | 7 | 2007.96 | 31 | 14.74 | 2861 | 1307 | 1.54 / 510.96 | 2 | 2 |
3 | 13 | 1756.28 | 20 | 14.71 | 2569 | 756 | 2.30 / 511.71 | 2 | 3 |
4 | 13 | 1313.60 | 20 | 14.74 | 2031 | 599 | 2.89 / 512.31 | 2 | 3 |
5 | 13 | 679.72 | 20 | 14.87 | 1230 | 366 | 3.26 / 512.68 | 2 | 4 |
6 | 13 | 14.88 | 20 | 15.05 | 328 | 99 | 3.36 / 512.78 | 2 | 3 |
7 | 8 | 0.00 | 165 | 15.01 | 303 | 750 | 4.11 / 513.53 | 2 | 5 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.88 | 33 | 14.95 | 449 | 222 | 0.22 / 505.67 | 2 | 2 |
2 | 3 | 1015.76 | 1 | 15.14 | 1690 | 26 | 0.25 / 505.70 | 2 | 2 |
3 | 7 | 2010.40 | 31 | 14.74 | 2861 | 1307 | 1.55 / 507.00 | 2 | 2 |
4 | 13 | 1588.24 | 20 | 14.75 | 2361 | 696 | 2.25 / 507.70 | 2 | 2 |
5 | 13 | 1159.08 | 20 | 14.77 | 1844 | 545 | 2.80 / 508.24 | 2 | 3 |
6 | 13 | 555.80 | 20 | 14.91 | 1063 | 317 | 3.11 / 508.56 | 2 | 2 |
7 | 13 | 42.00 | 20 | 15.04 | 362 | 109 | 3.22 / 508.67 | 2 | 2 |
8 | 8 | 0.00 | 165 | 15.00 | 302 | 747 | 3.97 / 509.42 | 2 | 5 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.16 | 33 | 14.94 | 459 | 226 | 0.23 / 501.89 | 2 | 2 |
2 | 7 | 2009.60 | 31 | 14.73 | 2860 | 1306 | 1.53 / 503.20 | 2 | 2 |
3 | 13 | 1630.88 | 20 | 14.73 | 2420 | 713 | 2.25 / 503.91 | 2 | 2 |
4 | 13 | 1057.08 | 20 | 14.79 | 1709 | 506 | 2.75 / 504.42 | 2 | 3 |
5 | 13 | 486.60 | 20 | 14.92 | 968 | 289 | 3.04 / 504.71 | 2 | 2 |
6 | 8 | 0.12 | 165 | 15.02 | 299 | 741 | 3.78 / 505.45 | 2 | 4 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.36 | 33 | 14.95 | 463 | 228 | 0.23 / 497.85 | 2 | 2 |
2 | 3 | 1026.00 | 1 | 15.09 | 1700 | 26 | 0.25 / 497.88 | 2 | 2 |
3 | 7 | 2011.04 | 31 | 14.73 | 2862 | 1307 | 1.56 / 499.18 | 2 | 2 |
4 | 13 | 1595.64 | 20 | 14.74 | 2367 | 698 | 2.26 / 499.88 | 2 | 2 |
5 | 13 | 1066.60 | 20 | 14.80 | 1715 | 508 | 2.77 / 500.39 | 2 | 3 |
6 | 13 | 494.64 | 20 | 14.92 | 971 | 290 | 3.06 / 500.68 | 2 | 2 |
7 | 13 | 35.36 | 20 | 15.04 | 350 | 105 | 3.16 / 500.78 | 2 | 2 |
8 | 8 | 0.16 | 165 | 15.00 | 303 | 750 | 3.91 / 501.53 | 2 | 2 |
9 | 14 | 0.16 | 30 | 14.98 | 302 | 136 | 4.05 / 501.67 | 2 | 2 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.56 | 34 | 14.94 | 459 | 233 | 0.23 / 494.02 | 2 | 2 |
2 | 3 | 972.88 | -1 | 15.40 | 0 | 0 | 0.00 / 494.02 | 2 | 2 |
3 | 7 | 2011.32 | 32 | 14.74 | 2861 | 1349 | 1.58 / 495.37 | 2 | 2 |
4 | 13 | 1620.96 | 20 | 14.73 | 2416 | 712 | 2.29 / 496.08 | 2 | 2 |
5 | 13 | 1069.32 | 20 | 14.80 | 1716 | 508 | 2.80 / 496.59 | 2 | 3 |
6 | 13 | 474.72 | 20 | 14.93 | 958 | 286 | 3.09 / 496.88 | 2 | 2 |
7 | 8 | 0.12 | 165 | 15.01 | 301 | 745 | 3.83 / 497.62 | 2 | 3 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.88 | 34 | 14.97 | 475 | 242 | 0.24 / 490.01 | 2 | 2 |
2 | 7 | 2018.36 | 31 | 14.70 | 2872 | 1309 | 1.55 / 491.32 | 2 | 2 |
3 | 13 | 1755.92 | 20 | 14.69 | 2563 | 753 | 2.30 / 492.07 | 2 | 2 |
4 | 13 | 1284.16 | 20 | 14.73 | 1998 | 589 | 2.89 / 492.66 | 2 | 4 |
5 | 13 | 507.44 | 20 | 14.91 | 993 | 296 | 3.19 / 492.96 | 2 | 2 |
6 | 13 | 16.76 | 20 | 15.04 | 321 | 97 | 3.28 / 493.05 | 2 | 2 |
7 | 8 | 0.04 | 165 | 15.01 | 296 | 733 | 4.02 / 493.79 | 2 | 4 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.20 | 34 | 14.93 | 459 | 233 | 0.23 / 486.88 | 2 | 2 |
2 | 7 | 1345.04 | 31 | 14.96 | 2054 | 953 | 1.19 / 487.83 | 2 | 2 |
3 | 13 | 1280.52 | 20 | 14.91 | 1973 | 588 | 1.77 / 488.42 | 2 | 3 |
4 | 13 | 912.72 | 20 | 14.94 | 1524 | 455 | 2.23 / 488.87 | 2 | 5 |
5 | 13 | 118.28 | 20 | 15.08 | 474 | 143 | 2.37 / 489.01 | 2 | 2 |
6 | 8 | 0.20 | 165 | 15.05 | 304 | 755 | 3.13 / 489.77 | 2 | 4 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.68 | 34 | 14.93 | 475 | 241 | 0.24 / 482.97 | 2 | 2 |
2 | 7 | 2003.48 | 31 | 14.74 | 2847 | 1301 | 1.54 / 484.27 | 2 | 2 |
3 | 13 | 1590.32 | 20 | 14.72 | 2366 | 697 | 2.24 / 484.97 | 2 | 2 |
4 | 13 | 1165.64 | 20 | 14.77 | 1831 | 541 | 2.78 / 485.51 | 2 | 4 |
5 | 13 | 450.60 | 20 | 14.93 | 914 | 273 | 3.05 / 485.78 | 2 | 2 |
6 | 8 | -0.08 | 165 | 14.99 | 295 | 730 | 3.78 / 486.51 | 2 | 3 |
7 | 14 | -0.08 | 30 | 14.97 | 297 | 133 | 3.92 / 486.64 | 2 | 3 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.56 | 34 | 14.94 | 480 | 244 | 0.24 / 479.10 | 2 | 2 |
2 | 7 | 2008.96 | 31 | 14.75 | 2852 | 1304 | 1.55 / 480.40 | 2 | 2 |
3 | 13 | 1622.32 | 20 | 14.74 | 2408 | 710 | 2.26 / 481.11 | 2 | 3 |
4 | 13 | 1188.96 | 20 | 14.77 | 1870 | 552 | 2.81 / 481.66 | 2 | 3 |
5 | 13 | 581.24 | 20 | 14.88 | 1086 | 323 | 3.13 / 481.99 | 2 | 4 |
6 | 8 | 0.20 | 165 | 14.99 | 299 | 740 | 3.87 / 482.73 | 2 | 4 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.76 | 34 | 14.94 | 452 | 230 | 0.23 / 475.21 | 2 | 2 |
2 | 7 | 2008.60 | 31 | 14.75 | 2855 | 1305 | 1.54 / 476.51 | 2 | 2 |
3 | 13 | 1732.72 | 20 | 14.72 | 2526 | 744 | 2.28 / 477.25 | 2 | 2 |
4 | 13 | 1144.72 | 20 | 14.79 | 1817 | 537 | 2.82 / 477.79 | 2 | 3 |
5 | 13 | 543.08 | 20 | 14.92 | 1029 | 307 | 3.12 / 478.10 | 2 | 3 |
6 | 8 | 0.20 | 165 | 15.00 | 305 | 755 | 3.88 / 478.85 | 2 | 3 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.56 | 34 | 14.93 | 465 | 236 | 0.24 / 471.39 | 2 | 2 |
2 | 7 | 2006.44 | 31 | 14.74 | 2858 | 1306 | 1.54 / 472.70 | 2 | 2 |
3 | 13 | 1748.40 | 20 | 14.71 | 2565 | 755 | 2.30 / 473.45 | 2 | 2 |
4 | 13 | 1185.20 | 20 | 14.76 | 1872 | 553 | 2.85 / 474.01 | 2 | 2 |
5 | 13 | 348.28 | 20 | 14.96 | 782 | 234 | 3.08 / 474.24 | 2 | 2 |
6 | 8 | 0.12 | 165 | 15.00 | 297 | 735 | 3.82 / 474.98 | 2 | 3 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.80 | 34 | 14.97 | 452 | 230 | 0.23 / 467.57 | 2 | 2 |
2 | 7 | 2005.56 | 31 | 14.75 | 2852 | 1304 | 1.53 / 468.87 | 2 | 2 |
3 | 13 | 1622.72 | 20 | 14.74 | 2410 | 710 | 2.24 / 469.58 | 2 | 2 |
4 | 13 | 1204.24 | 20 | 14.76 | 1890 | 558 | 2.80 / 470.14 | 2 | 3 |
5 | 13 | 464.28 | 20 | 14.93 | 929 | 277 | 3.08 / 470.42 | 2 | 2 |
6 | 8 | 0.40 | 165 | 15.00 | 300 | 742 | 3.82 / 471.16 | 2 | 3 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.20 | 34 | 14.95 | 466 | 237 | 0.24 / 463.73 | 2 | 2 |
2 | 7 | 2013.68 | 31 | 14.75 | 2859 | 1307 | 1.54 / 465.04 | 2 | 2 |
3 | 13 | 1624.12 | 20 | 14.74 | 2426 | 715 | 2.26 / 465.76 | 2 | 3 |
4 | 13 | 1193.36 | 20 | 14.76 | 1887 | 557 | 2.82 / 466.31 | 2 | 3 |
5 | 13 | 461.72 | 20 | 14.93 | 931 | 278 | 3.09 / 466.59 | 2 | 2 |
6 | 8 | -0.04 | 165 | 15.01 | 300 | 743 | 3.84 / 467.34 | 2 | 4 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.88 | 34 | 14.96 | 465 | 237 | 0.24 / 459.90 | 2 | 2 |
2 | 7 | 2004.76 | 31 | 14.75 | 2849 | 1303 | 1.54 / 461.20 | 2 | 2 |
3 | 13 | 1716.16 | 20 | 14.74 | 2536 | 748 | 2.29 / 461.95 | 2 | 2 |
4 | 13 | 1145.24 | 20 | 14.80 | 1813 | 537 | 2.82 / 462.48 | 2 | 4 |
5 | 13 | 435.88 | 20 | 14.95 | 895 | 268 | 3.09 / 462.75 | 2 | 2 |
6 | 8 | 0.04 | 165 | 15.01 | 302 | 748 | 3.84 / 463.50 | 2 | 3 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.84 | 34 | 14.95 | 466 | 237 | 0.24 / 456.07 | 2 | 2 |
2 | 7 | 2008.28 | 31 | 14.75 | 2850 | 1303 | 1.54 / 457.37 | 2 | 2 |
3 | 13 | 1879.16 | 20 | 14.71 | 2723 | 801 | 2.34 / 458.17 | 2 | 3 |
4 | 13 | 1108.64 | 20 | 14.80 | 1755 | 519 | 2.86 / 458.69 | 2 | 3 |
5 | 13 | 381.52 | 20 | 14.96 | 805 | 241 | 3.10 / 458.93 | 2 | 2 |
6 | 8 | 0.08 | 165 | 15.02 | 293 | 726 | 3.83 / 459.66 | 2 | 3 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.84 | 34 | 14.96 | 462 | 235 | 0.23 / 452.06 | 2 | 2 |
2 | 7 | 2004.56 | 31 | 14.74 | 2855 | 1305 | 1.54 / 453.36 | 2 | 2 |
3 | 13 | 1728.68 | 20 | 14.72 | 2550 | 751 | 2.29 / 454.11 | 2 | 2 |
4 | 13 | 1168.40 | 20 | 14.77 | 1860 | 549 | 2.84 / 454.66 | 2 | 3 |
5 | 13 | 438.52 | 20 | 14.94 | 906 | 271 | 3.11 / 454.93 | 2 | 2 |
6 | 8 | 0.04 | 165 | 15.02 | 306 | 758 | 3.87 / 455.69 | 2 | 2 |
7 | 14 | 0.04 | 30 | 14.99 | 310 | 139 | 4.01 / 455.83 | 2 | 2 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.92 | 33 | 14.95 | 469 | 231 | 0.23 / 448.24 | 2 | 2 |
2 | 7 | 2002.56 | 31 | 14.74 | 2846 | 1300 | 1.53 / 449.54 | 2 | 2 |
3 | 13 | 1735.08 | 20 | 14.72 | 2553 | 752 | 2.28 / 450.29 | 2 | 2 |
4 | 13 | 1033.36 | 20 | 14.81 | 1686 | 499 | 2.78 / 450.79 | 2 | 3 |
5 | 13 | 458.80 | 20 | 14.93 | 930 | 278 | 3.06 / 451.07 | 2 | 2 |
6 | 8 | 0.32 | 165 | 15.01 | 305 | 755 | 3.82 / 451.82 | 2 | 3 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.24 | 33 | 14.95 | 467 | 230 | 0.23 / 444.38 | 2 | 2 |
2 | 7 | 2002.96 | 32 | 14.75 | 2853 | 1347 | 1.58 / 445.73 | 2 | 2 |
3 | 13 | 1720.44 | 20 | 14.73 | 2529 | 745 | 2.32 / 446.47 | 2 | 2 |
4 | 13 | 1133.80 | 20 | 14.78 | 1817 | 537 | 2.86 / 447.01 | 2 | 4 |
5 | 13 | 384.04 | 20 | 14.96 | 824 | 247 | 3.11 / 447.26 | 2 | 2 |
6 | 8 | 0.08 | 165 | 15.01 | 303 | 750 | 3.86 / 448.01 | 2 | 6 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.00 | 33 | 14.97 | 465 | 230 | 0.23 / 440.57 | 2 | 2 |
2 | 7 | 2008.48 | 31 | 14.74 | 2858 | 1306 | 1.54 / 441.87 | 2 | 2 |
3 | 13 | 1738.48 | 20 | 14.73 | 2536 | 747 | 2.28 / 442.62 | 2 | 2 |
4 | 13 | 1138.20 | 20 | 14.78 | 1811 | 535 | 2.82 / 443.15 | 2 | 3 |
5 | 13 | 410.72 | 20 | 14.95 | 855 | 256 | 3.07 / 443.41 | 2 | 2 |
6 | 8 | 0.44 | 165 | 15.02 | 299 | 741 | 3.81 / 444.15 | 2 | 4 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.60 | 33 | 14.96 | 484 | 239 | 0.24 / 436.64 | 2 | 2 |
2 | 7 | 2006.76 | 31 | 14.77 | 2849 | 1304 | 1.54 / 437.94 | 2 | 2 |
3 | 13 | 1878.48 | 20 | 14.72 | 2702 | 795 | 2.34 / 438.74 | 2 | 3 |
4 | 13 | 1151.28 | 20 | 14.78 | 1826 | 540 | 2.88 / 439.27 | 2 | 2 |
5 | 13 | 547.20 | 20 | 14.93 | 1048 | 313 | 3.19 / 439.59 | 2 | 2 |
6 | 8 | -0.20 | 165 | 15.02 | 302 | 748 | 3.94 / 440.34 | 2 | 3 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.60 | 33 | 14.96 | 461 | 228 | 0.23 / 432.78 | 2 | 2 |
2 | 7 | 2004.56 | 32 | 14.74 | 2858 | 1348 | 1.58 / 434.13 | 2 | 2 |
3 | 13 | 1603.60 | 20 | 14.74 | 2395 | 706 | 2.28 / 434.83 | 2 | 2 |
4 | 13 | 1051.92 | 20 | 14.81 | 1708 | 506 | 2.79 / 435.34 | 2 | 3 |
5 | 13 | 475.44 | 20 | 14.94 | 964 | 288 | 3.08 / 435.63 | 2 | 2 |
6 | 8 | 0.16 | 165 | 15.02 | 310 | 768 | 3.84 / 436.40 | 2 | 4 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.72 | 33 | 14.98 | 465 | 230 | 0.23 / 428.88 | 2 | 2 |
2 | 7 | 2005.40 | 31 | 14.75 | 2870 | 1312 | 1.54 / 430.19 | 2 | 2 |
3 | 13 | 1727.12 | 20 | 14.72 | 2554 | 752 | 2.29 / 430.94 | 2 | 2 |
4 | 13 | 1139.08 | 20 | 14.79 | 1822 | 539 | 2.83 / 431.48 | 2 | 4 |
5 | 13 | 540.52 | 20 | 14.93 | 1049 | 313 | 3.15 / 431.79 | 2 | 3 |
6 | 8 | 0.00 | 165 | 15.02 | 307 | 761 | 3.91 / 432.55 | 2 | 6 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.56 | 33 | 14.95 | 473 | 233 | 0.23 / 425.05 | 2 | 2 |
2 | 7 | 2012.76 | 31 | 14.75 | 2872 | 1313 | 1.55 / 426.36 | 2 | 2 |
3 | 13 | 1740.40 | 20 | 14.73 | 2562 | 755 | 2.30 / 427.12 | 2 | 3 |
4 | 13 | 1034.72 | 20 | 14.82 | 1693 | 502 | 2.80 / 427.62 | 2 | 3 |
5 | 13 | 456.08 | 20 | 14.96 | 931 | 279 | 3.08 / 427.90 | 2 | 2 |
6 | 8 | 0.12 | 165 | 15.03 | 302 | 749 | 3.83 / 428.65 | 2 | 6 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.52 | 33 | 14.96 | 474 | 234 | 0.23 / 421.09 | 2 | 2 |
2 | 7 | 2002.56 | 31 | 14.75 | 2853 | 1305 | 1.54 / 422.39 | 2 | 2 |
3 | 13 | 1726.80 | 20 | 14.72 | 2542 | 748 | 2.29 / 423.14 | 2 | 2 |
4 | 13 | 1153.52 | 20 | 14.78 | 1835 | 542 | 2.83 / 423.68 | 2 | 2 |
5 | 13 | 423.56 | 20 | 14.96 | 882 | 264 | 3.09 / 423.95 | 2 | 2 |
6 | 13 | 45.64 | 20 | 15.06 | 375 | 113 | 3.21 / 424.06 | 2 | 2 |
7 | 8 | 0.16 | 165 | 15.02 | 304 | 753 | 3.96 / 424.81 | 2 | 6 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.24 | 33 | 14.97 | 455 | 225 | 0.22 / 417.28 | 2 | 2 |
2 | 7 | 2006.88 | 31 | 14.75 | 2846 | 1301 | 1.53 / 418.58 | 2 | 2 |
3 | 13 | 1605.92 | 20 | 14.74 | 2396 | 706 | 2.23 / 419.29 | 2 | 2 |
4 | 13 | 1170.32 | 20 | 14.78 | 1840 | 544 | 2.78 / 419.83 | 2 | 3 |
5 | 13 | 434.24 | 20 | 14.95 | 893 | 267 | 3.04 / 420.10 | 2 | 2 |
6 | 8 | 0.28 | 165 | 15.02 | 304 | 753 | 3.80 / 420.86 | 2 | 3 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.04 | 33 | 14.98 | 455 | 225 | 0.22 / 413.29 | 2 | 2 |
2 | 7 | 2003.24 | 31 | 14.75 | 2860 | 1308 | 1.53 / 414.60 | 2 | 2 |
3 | 13 | 1610.32 | 20 | 14.75 | 2402 | 709 | 2.24 / 415.31 | 2 | 2 |
4 | 13 | 1061.12 | 20 | 14.81 | 1722 | 510 | 2.75 / 415.82 | 2 | 3 |
5 | 13 | 361.48 | 20 | 14.98 | 803 | 241 | 2.99 / 416.06 | 2 | 2 |
6 | 13 | 40.96 | 20 | 15.05 | 368 | 111 | 3.10 / 416.17 | 2 | 2 |
7 | 8 | 0.28 | 165 | 15.02 | 304 | 753 | 3.86 / 416.92 | 2 | 2 |
8 | 14 | 0.28 | 30 | 15.00 | 305 | 137 | 3.99 / 417.06 | 2 | 5 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.00 | 33 | 14.96 | 470 | 232 | 0.23 / 409.50 | 2 | 2 |
2 | 7 | 2015.36 | 31 | 14.75 | 2871 | 1313 | 1.54 / 410.82 | 2 | 2 |
3 | 13 | 1622.36 | 20 | 14.75 | 2414 | 712 | 2.26 / 411.53 | 2 | 2 |
4 | 13 | 1192.04 | 20 | 14.78 | 1881 | 556 | 2.81 / 412.08 | 2 | 3 |
5 | 13 | 347.64 | 20 | 14.99 | 784 | 235 | 3.05 / 412.32 | 2 | 2 |
6 | 8 | 0.12 | 165 | 15.03 | 301 | 746 | 3.79 / 413.07 | 2 | 4 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.92 | 33 | 14.97 | 469 | 232 | 0.23 / 405.58 | 2 | 2 |
2 | 7 | 2004.72 | 31 | 14.77 | 2868 | 1313 | 1.54 / 406.90 | 2 | 2 |
3 | 13 | 1589.56 | 20 | 14.77 | 2381 | 703 | 2.25 / 407.60 | 2 | 2 |
4 | 13 | 1163.08 | 20 | 14.80 | 1852 | 548 | 2.80 / 408.15 | 2 | 3 |
5 | 13 | 420.96 | 20 | 14.97 | 884 | 265 | 3.06 / 408.41 | 2 | 3 |
6 | 13 | 23.76 | 20 | 15.07 | 342 | 103 | 3.16 / 408.51 | 2 | 2 |
7 | 8 | 0.20 | 165 | 15.02 | 305 | 756 | 3.92 / 409.27 | 2 | 4 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.68 | 33 | 14.96 | 469 | 232 | 0.23 / 401.58 | 2 | 2 |
2 | 7 | 2005.84 | 31 | 14.77 | 2859 | 1309 | 1.54 / 402.89 | 2 | 2 |
3 | 13 | 1720.32 | 20 | 14.75 | 2528 | 746 | 2.29 / 403.64 | 2 | 2 |
4 | 13 | 1128.84 | 20 | 14.82 | 1808 | 536 | 2.82 / 404.17 | 2 | 3 |
5 | 13 | 535.56 | 20 | 14.94 | 1040 | 311 | 3.13 / 404.48 | 2 | 3 |
6 | 13 | 22.80 | 20 | 15.07 | 343 | 103 | 3.24 / 404.59 | 2 | 2 |
7 | 8 | 0.04 | 165 | 15.02 | 308 | 763 | 4.00 / 405.35 | 2 | 4 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.88 | 33 | 14.95 | 478 | 236 | 0.24 / 397.74 | 2 | 2 |
2 | 7 | 2011.76 | 31 | 14.76 | 2867 | 1312 | 1.55 / 399.06 | 2 | 2 |
3 | 13 | 1606.20 | 20 | 14.76 | 2393 | 706 | 2.25 / 399.76 | 2 | 3 |
4 | 13 | 1044.28 | 20 | 14.83 | 1695 | 503 | 2.76 / 400.27 | 2 | 3 |
5 | 13 | 338.12 | 20 | 14.99 | 773 | 232 | 2.99 / 400.50 | 2 | 2 |
6 | 13 | 36.04 | 20 | 15.06 | 356 | 107 | 3.10 / 400.60 | 2 | 2 |
7 | 8 | -0.08 | 165 | 15.02 | 301 | 746 | 3.84 / 401.35 | 2 | 4 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.60 | 33 | 14.96 | 471 | 233 | 0.23 / 393.77 | 2 | 2 |
2 | 7 | 2004.00 | 31 | 14.75 | 2851 | 1304 | 1.54 / 395.07 | 2 | 2 |
3 | 13 | 1727.92 | 20 | 14.73 | 2534 | 747 | 2.28 / 395.82 | 2 | 2 |
4 | 13 | 1143.32 | 20 | 14.81 | 1810 | 536 | 2.82 / 396.35 | 2 | 4 |
5 | 13 | 425.76 | 20 | 14.97 | 886 | 265 | 3.08 / 396.62 | 2 | 2 |
6 | 13 | 49.88 | 20 | 15.04 | 390 | 117 | 3.20 / 396.74 | 2 | 2 |
7 | 8 | 0.08 | 165 | 15.01 | 312 | 773 | 3.97 / 397.51 | 2 | 4 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.64 | 34 | 14.96 | 455 | 231 | 0.23 / 389.93 | 2 | 2 |
2 | 7 | 2003.76 | 31 | 14.77 | 2854 | 1307 | 1.54 / 391.23 | 2 | 2 |
3 | 13 | 1602.48 | 20 | 14.76 | 2394 | 707 | 2.24 / 391.94 | 2 | 2 |
4 | 13 | 1059.08 | 20 | 14.83 | 1725 | 512 | 2.76 / 392.45 | 2 | 3 |
5 | 13 | 339.12 | 20 | 14.99 | 776 | 233 | 2.99 / 392.69 | 2 | 2 |
6 | 13 | 17.12 | 20 | 15.06 | 326 | 98 | 3.09 / 392.78 | 2 | 2 |
7 | 8 | -0.08 | 165 | 15.02 | 303 | 751 | 3.84 / 393.54 | 2 | 4 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.72 | 33 | 14.96 | 473 | 234 | 0.23 / 385.96 | 2 | 2 |
2 | 7 | 2003.20 | 31 | 14.78 | 2852 | 1307 | 1.54 / 387.27 | 2 | 2 |
3 | 13 | 1619.44 | 20 | 14.76 | 2411 | 712 | 2.25 / 387.98 | 2 | 2 |
4 | 13 | 1201.96 | 20 | 14.80 | 1896 | 561 | 2.81 / 388.54 | 2 | 3 |
5 | 13 | 474.72 | 20 | 14.96 | 961 | 288 | 3.10 / 388.83 | 2 | 3 |
6 | 13 | 31.64 | 20 | 15.06 | 352 | 106 | 3.21 / 388.94 | 2 | 2 |
7 | 8 | 0.12 | 165 | 15.02 | 307 | 761 | 3.97 / 389.70 | 2 | 4 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.48 | 33 | 14.96 | 469 | 232 | 0.23 / 381.97 | 2 | 2 |
2 | 7 | 2005.92 | 31 | 14.77 | 2865 | 1312 | 1.54 / 383.28 | 2 | 2 |
3 | 13 | 1732.84 | 20 | 14.74 | 2552 | 752 | 2.30 / 384.03 | 2 | 2 |
4 | 13 | 1154.40 | 20 | 14.81 | 1831 | 542 | 2.84 / 384.58 | 2 | 3 |
5 | 13 | 420.92 | 20 | 14.98 | 888 | 266 | 3.10 / 384.84 | 2 | 2 |
6 | 13 | 48.04 | 20 | 15.06 | 388 | 117 | 3.22 / 384.96 | 2 | 3 |
7 | 8 | 0.16 | 165 | 15.02 | 311 | 771 | 3.99 / 385.73 | 2 | 3 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.36 | 33 | 14.97 | 468 | 231 | 0.23 / 377.90 | 2 | 2 |
2 | 7 | 2003.64 | 31 | 14.79 | 2865 | 1314 | 1.54 / 379.21 | 2 | 2 |
3 | 13 | 1746.52 | 20 | 14.76 | 2572 | 759 | 2.30 / 379.97 | 2 | 3 |
4 | 13 | 1278.80 | 20 | 14.78 | 1995 | 590 | 2.89 / 380.56 | 2 | 4 |
5 | 13 | 506.00 | 20 | 14.95 | 1001 | 299 | 3.19 / 380.86 | 2 | 3 |
6 | 13 | 37.04 | 20 | 15.05 | 367 | 110 | 3.30 / 380.97 | 2 | 2 |
7 | 8 | -0.16 | 165 | 15.02 | 309 | 766 | 4.07 / 381.74 | 2 | 3 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.56 | 33 | 14.96 | 461 | 228 | 0.23 / 373.94 | 2 | 2 |
2 | 7 | 2005.00 | 31 | 14.78 | 2861 | 1311 | 1.54 / 375.25 | 2 | 2 |
3 | 13 | 1732.44 | 20 | 14.76 | 2546 | 752 | 2.29 / 376.00 | 2 | 2 |
4 | 13 | 1162.72 | 20 | 14.81 | 1848 | 547 | 2.84 / 376.55 | 2 | 3 |
5 | 13 | 435.96 | 20 | 14.97 | 893 | 267 | 3.10 / 376.82 | 2 | 2 |
6 | 13 | 28.96 | 20 | 15.06 | 340 | 102 | 3.21 / 376.92 | 2 | 2 |
7 | 8 | 0.08 | 165 | 15.03 | 301 | 746 | 3.95 / 377.67 | 2 | 3 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.68 | 33 | 14.97 | 469 | 232 | 0.23 / 370.02 | 2 | 2 |
2 | 7 | 2003.36 | 31 | 14.77 | 2862 | 1310 | 1.54 / 371.33 | 2 | 2 |
3 | 13 | 1604.16 | 20 | 14.76 | 2391 | 706 | 2.25 / 372.03 | 2 | 3 |
4 | 13 | 1178.52 | 20 | 14.79 | 1871 | 553 | 2.80 / 372.59 | 2 | 3 |
5 | 13 | 417.24 | 20 | 14.97 | 874 | 262 | 3.06 / 372.85 | 2 | 3 |
6 | 13 | 53.08 | 20 | 15.05 | 385 | 116 | 3.18 / 372.96 | 2 | 2 |
7 | 8 | 0.08 | 165 | 15.01 | 303 | 750 | 3.93 / 373.71 | 2 | 5 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.44 | 33 | 14.96 | 471 | 233 | 0.23 / 366.06 | 2 | 2 |
2 | 7 | 2003.88 | 31 | 14.77 | 2858 | 1309 | 1.54 / 367.36 | 2 | 2 |
3 | 13 | 1609.84 | 20 | 14.75 | 2402 | 709 | 2.25 / 368.07 | 2 | 2 |
4 | 13 | 1185.76 | 20 | 14.80 | 1883 | 557 | 2.81 / 368.63 | 2 | 3 |
5 | 13 | 455.56 | 20 | 14.96 | 930 | 278 | 3.09 / 368.91 | 2 | 3 |
6 | 13 | 57.24 | 20 | 15.05 | 395 | 119 | 3.20 / 369.03 | 2 | 2 |
7 | 8 | -0.16 | 165 | 15.02 | 306 | 758 | 3.96 / 369.79 | 2 | 4 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.44 | 33 | 14.97 | 442 | 218 | 0.22 / 362.17 | 2 | 2 |
2 | 7 | 2004.32 | 32 | 14.78 | 2855 | 1350 | 1.57 / 363.52 | 2 | 2 |
3 | 13 | 1594.32 | 20 | 14.77 | 2371 | 700 | 2.27 / 364.22 | 2 | 2 |
4 | 13 | 1051.04 | 20 | 14.82 | 1705 | 505 | 2.77 / 364.73 | 2 | 3 |
5 | 13 | 348.28 | 20 | 14.99 | 781 | 234 | 3.01 / 364.96 | 2 | 3 |
6 | 13 | 42.28 | 20 | 15.06 | 370 | 111 | 3.12 / 365.07 | 2 | 2 |
7 | 8 | 0.24 | 165 | 15.03 | 303 | 751 | 3.87 / 365.82 | 2 | 4 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.24 | 33 | 14.96 | 474 | 234 | 0.23 / 358.25 | 2 | 2 |
2 | 7 | 2011.04 | 31 | 14.77 | 2872 | 1315 | 1.55 / 359.57 | 2 | 2 |
3 | 13 | 1607.08 | 20 | 14.77 | 2403 | 710 | 2.26 / 360.28 | 2 | 2 |
4 | 13 | 1168.04 | 20 | 14.80 | 1854 | 549 | 2.81 / 360.83 | 2 | 3 |
5 | 13 | 420.48 | 20 | 14.97 | 883 | 264 | 3.07 / 361.09 | 2 | 2 |
6 | 13 | 32.56 | 20 | 15.06 | 357 | 108 | 3.18 / 361.20 | 2 | 2 |
7 | 8 | 0.04 | 165 | 15.03 | 304 | 754 | 3.93 / 361.95 | 2 | 6 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.32 | 33 | 14.97 | 451 | 223 | 0.22 / 354.34 | 2 | 2 |
2 | 7 | 2006.04 | 31 | 14.77 | 2863 | 1311 | 1.53 / 355.65 | 2 | 2 |
3 | 13 | 1604.12 | 20 | 14.77 | 2399 | 709 | 2.24 / 356.36 | 2 | 3 |
4 | 13 | 1046.44 | 20 | 14.84 | 1706 | 506 | 2.75 / 356.87 | 2 | 3 |
5 | 13 | 466.84 | 20 | 14.97 | 951 | 285 | 3.03 / 357.15 | 2 | 2 |
6 | 13 | 11.44 | 20 | 15.08 | 326 | 98 | 3.13 / 357.25 | 2 | 2 |
7 | 8 | 0.04 | 165 | 15.03 | 309 | 766 | 3.90 / 358.02 | 2 | 2 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.56 | 33 | 14.97 | 471 | 233 | 0.23 / 350.42 | 2 | 2 |
2 | 7 | 2007.92 | 31 | 14.79 | 2873 | 1317 | 1.55 / 351.74 | 2 | 2 |
3 | 13 | 1592.16 | 20 | 14.79 | 2388 | 706 | 2.26 / 352.45 | 2 | 2 |
4 | 13 | 1159.08 | 20 | 14.83 | 1847 | 548 | 2.80 / 353.00 | 2 | 4 |
5 | 13 | 404.84 | 20 | 15.00 | 865 | 259 | 3.06 / 353.26 | 2 | 2 |
6 | 13 | 19.60 | 20 | 15.08 | 339 | 102 | 3.17 / 353.36 | 2 | 2 |
7 | 8 | 0.20 | 165 | 15.04 | 307 | 762 | 3.93 / 354.12 | 2 | 5 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.60 | 33 | 14.98 | 471 | 233 | 0.23 / 346.45 | 2 | 2 |
2 | 7 | 2008.96 | 31 | 14.80 | 2863 | 1314 | 1.55 / 347.77 | 2 | 2 |
3 | 13 | 1722.84 | 20 | 14.77 | 2547 | 752 | 2.30 / 348.52 | 2 | 2 |
4 | 13 | 1148.60 | 20 | 14.81 | 1831 | 542 | 2.84 / 349.06 | 2 | 4 |
5 | 13 | 421.76 | 20 | 14.99 | 889 | 267 | 3.11 / 349.33 | 2 | 3 |
6 | 13 | 17.72 | 20 | 15.08 | 336 | 101 | 3.21 / 349.43 | 2 | 2 |
7 | 8 | 0.08 | 165 | 15.03 | 307 | 761 | 3.97 / 350.19 | 2 | 4 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.96 | 33 | 14.99 | 475 | 235 | 0.23 / 342.50 | 2 | 2 |
2 | 7 | 2009.12 | 31 | 14.80 | 2876 | 1320 | 1.55 / 343.82 | 2 | 2 |
3 | 13 | 1590.08 | 20 | 14.79 | 2388 | 706 | 2.26 / 344.52 | 2 | 2 |
4 | 13 | 1160.48 | 20 | 14.83 | 1848 | 548 | 2.81 / 345.07 | 2 | 3 |
5 | 13 | 421.08 | 20 | 15.00 | 890 | 267 | 3.08 / 345.34 | 2 | 3 |
6 | 13 | 21.12 | 20 | 15.09 | 346 | 104 | 3.18 / 345.44 | 2 | 2 |
7 | 8 | 0.04 | 165 | 15.05 | 313 | 777 | 3.96 / 346.22 | 2 | 3 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.84 | 33 | 15.00 | 472 | 234 | 0.23 / 338.50 | 2 | 2 |
2 | 7 | 2010.60 | 31 | 14.81 | 2869 | 1317 | 1.55 / 339.82 | 2 | 2 |
3 | 13 | 1734.20 | 20 | 14.78 | 2546 | 753 | 2.30 / 340.57 | 2 | 2 |
4 | 13 | 1156.52 | 20 | 14.85 | 1839 | 546 | 2.85 / 341.12 | 2 | 3 |
5 | 13 | 438.84 | 20 | 15.00 | 915 | 274 | 3.12 / 341.39 | 2 | 3 |
6 | 13 | 19.92 | 20 | 15.10 | 342 | 103 | 3.23 / 341.49 | 2 | 2 |
7 | 8 | 0.20 | 165 | 15.05 | 310 | 770 | 4.00 / 342.26 | 2 | 4 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.16 | 33 | 15.01 | 462 | 229 | 0.23 / 334.69 | 2 | 2 |
2 | 7 | 2006.84 | 32 | 14.78 | 2863 | 1354 | 1.58 / 336.04 | 2 | 2 |
3 | 13 | 1592.80 | 20 | 14.79 | 2372 | 702 | 2.28 / 336.74 | 2 | 2 |
4 | 13 | 1034.72 | 20 | 14.85 | 1679 | 499 | 2.78 / 337.24 | 2 | 4 |
5 | 13 | 454.48 | 20 | 14.99 | 921 | 276 | 3.06 / 337.52 | 2 | 2 |
6 | 8 | 0.04 | 165 | 15.06 | 302 | 750 | 3.81 / 338.27 | 2 | 4 |
Average= | 3.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.16 | 33 | 15.01 | 466 | 231 | 0.23 / 330.71 | 2 | 2 |
2 | 7 | 2006.24 | 31 | 14.78 | 2862 | 1311 | 1.54 / 332.02 | 2 | 2 |
3 | 13 | 1735.84 | 20 | 14.77 | 2566 | 758 | 2.30 / 332.78 | 2 | 2 |
4 | 13 | 1147.84 | 20 | 14.83 | 1839 | 545 | 2.85 / 333.33 | 2 | 3 |
5 | 13 | 430.32 | 20 | 15.01 | 898 | 270 | 3.12 / 333.60 | 2 | 2 |
6 | 13 | 15.44 | 20 | 15.10 | 330 | 100 | 3.21 / 333.70 | 2 | 2 |
7 | 8 | 0.08 | 165 | 15.06 | 306 | 760 | 3.98 / 334.46 | 2 | 2 |
Average= | 3.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.00 | 33 | 15.00 | 459 | 227 | 0.23 / 326.88 | 2 | 2 |
2 | 7 | 2008.08 | 31 | 14.80 | 2865 | 1314 | 1.54 / 328.20 | 2 | 2 |
3 | 13 | 1732.44 | 20 | 14.78 | 2547 | 753 | 2.29 / 328.95 | 2 | 2 |
4 | 13 | 1024.20 | 20 | 14.87 | 1670 | 497 | 2.79 / 329.44 | 2 | 3 |
5 | 13 | 456.20 | 20 | 15.00 | 936 | 281 | 3.07 / 329.73 | 2 | 2 |
6 | 8 | -0.12 | 165 | 15.08 | 304 | 756 | 3.83 / 330.48 | 2 | 3 |
Average= | 3.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.24 | 33 | 15.01 | 476 | 236 | 0.24 / 323.09 | 2 | 2 |
2 | 7 | 2003.40 | 31 | 14.78 | 2856 | 1309 | 1.54 / 324.40 | 2 | 2 |
3 | 13 | 1605.72 | 20 | 14.79 | 2397 | 709 | 2.25 / 325.11 | 2 | 2 |
4 | 13 | 1166.48 | 20 | 14.82 | 1855 | 550 | 2.80 / 325.66 | 2 | 3 |
5 | 13 | 425.36 | 20 | 15.00 | 886 | 266 | 3.07 / 325.92 | 2 | 2 |
6 | 8 | 0.08 | 165 | 15.07 | 293 | 729 | 3.80 / 326.65 | 2 | 4 |
Average= | 3.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.56 | 33 | 15.02 | 474 | 235 | 0.23 / 319.19 | 2 | 2 |
2 | 7 | 2005.36 | 31 | 14.80 | 2876 | 1320 | 1.55 / 320.51 | 2 | 2 |
3 | 13 | 1736.00 | 20 | 14.77 | 2568 | 759 | 2.31 / 321.27 | 2 | 2 |
4 | 13 | 1152.28 | 20 | 14.84 | 1845 | 548 | 2.86 / 321.82 | 2 | 3 |
5 | 13 | 418.00 | 20 | 15.01 | 891 | 267 | 3.13 / 322.08 | 2 | 2 |
6 | 8 | 0.00 | 165 | 15.07 | 311 | 773 | 3.90 / 322.86 | 2 | 3 |
Average= | 3.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.36 | 33 | 15.03 | 465 | 231 | 0.23 / 315.31 | 2 | 2 |
2 | 7 | 2010.72 | 31 | 14.79 | 2874 | 1318 | 1.55 / 316.63 | 2 | 2 |
3 | 13 | 1726.92 | 20 | 14.78 | 2562 | 757 | 2.31 / 317.39 | 2 | 2 |
4 | 13 | 1133.72 | 20 | 14.85 | 1814 | 539 | 2.84 / 317.93 | 2 | 3 |
5 | 13 | 404.64 | 20 | 15.03 | 866 | 260 | 3.10 / 318.19 | 2 | 2 |
6 | 8 | 0.12 | 165 | 15.08 | 309 | 769 | 3.87 / 318.95 | 2 | 3 |
Average= | 3.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.96 | 33 | 15.02 | 479 | 237 | 0.24 / 311.55 | 2 | 2 |
2 | 7 | 2005.12 | 31 | 14.79 | 2869 | 1315 | 1.55 / 312.87 | 2 | 2 |
3 | 13 | 1598.20 | 20 | 14.81 | 2401 | 711 | 2.26 / 313.58 | 2 | 2 |
4 | 13 | 1052.68 | 20 | 14.87 | 1712 | 509 | 2.77 / 314.09 | 2 | 5 |
5 | 13 | 337.12 | 20 | 15.04 | 775 | 233 | 3.01 / 314.32 | 2 | 2 |
6 | 8 | 0.12 | 165 | 15.08 | 305 | 759 | 3.77 / 315.08 | 2 | 3 |
Average= | 3.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.44 | 33 | 15.03 | 470 | 233 | 0.23 / 307.64 | 2 | 2 |
2 | 7 | 2012.92 | 32 | 14.80 | 2873 | 1361 | 1.59 / 309.00 | 2 | 2 |
3 | 13 | 1612.44 | 20 | 14.81 | 2414 | 715 | 2.31 / 309.72 | 2 | 3 |
4 | 13 | 1169.96 | 20 | 14.83 | 1861 | 552 | 2.86 / 310.27 | 2 | 3 |
5 | 13 | 427.16 | 20 | 15.01 | 905 | 272 | 3.13 / 310.54 | 2 | 2 |
6 | 8 | 0.16 | 165 | 15.09 | 312 | 777 | 3.91 / 311.32 | 2 | 4 |
Average= | 3.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.80 | 33 | 15.03 | 476 | 236 | 0.24 / 303.81 | 2 | 2 |
2 | 7 | 2003.60 | 31 | 14.80 | 2864 | 1314 | 1.55 / 305.12 | 2 | 2 |
3 | 13 | 1607.12 | 20 | 14.80 | 2411 | 714 | 2.26 / 305.84 | 2 | 2 |
4 | 13 | 1044.56 | 20 | 14.87 | 1718 | 511 | 2.77 / 306.35 | 2 | 3 |
5 | 13 | 453.12 | 20 | 15.01 | 946 | 284 | 3.06 / 306.63 | 2 | 2 |
6 | 8 | 0.04 | 165 | 15.09 | 311 | 774 | 3.83 / 307.41 | 2 | 5 |
Average= | 3.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.36 | 33 | 15.03 | 482 | 239 | 0.24 / 299.99 | 2 | 2 |
2 | 7 | 2008.92 | 31 | 14.80 | 2878 | 1320 | 1.56 / 301.31 | 2 | 2 |
3 | 13 | 1596.44 | 20 | 14.79 | 2395 | 708 | 2.27 / 302.02 | 2 | 2 |
4 | 13 | 1043.52 | 20 | 14.87 | 1696 | 504 | 2.77 / 302.52 | 2 | 4 |
5 | 13 | 448.92 | 20 | 15.02 | 921 | 277 | 3.05 / 302.80 | 2 | 3 |
6 | 8 | -0.04 | 165 | 15.09 | 310 | 772 | 3.82 / 303.57 | 2 | 2 |
Average= | 3.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.16 | 33 | 15.05 | 478 | 237 | 0.24 / 296.01 | 2 | 2 |
2 | 7 | 2002.92 | 31 | 14.82 | 2866 | 1317 | 1.55 / 297.33 | 2 | 2 |
3 | 13 | 1600.92 | 20 | 14.82 | 2409 | 714 | 2.27 / 298.04 | 2 | 2 |
4 | 13 | 1055.80 | 20 | 14.88 | 1722 | 512 | 2.78 / 298.56 | 2 | 3 |
5 | 13 | 482.16 | 20 | 15.01 | 965 | 290 | 3.07 / 298.85 | 2 | 3 |
6 | 8 | -0.04 | 165 | 15.09 | 307 | 764 | 3.83 / 299.61 | 2 | 2 |
7 | 14 | -0.04 | 30 | 15.07 | 312 | 141 | 3.98 / 299.75 | 2 | 3 |
Average= | 3.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.12 | 33 | 15.05 | 475 | 236 | 0.24 / 292.13 | 2 | 2 |
2 | 7 | 2005.24 | 31 | 14.81 | 2869 | 1317 | 1.55 / 293.45 | 2 | 2 |
3 | 13 | 1733.96 | 20 | 14.80 | 2562 | 758 | 2.31 / 294.20 | 2 | 2 |
4 | 13 | 1119.24 | 20 | 14.87 | 1804 | 537 | 2.85 / 294.74 | 2 | 3 |
5 | 13 | 400.52 | 20 | 15.05 | 866 | 261 | 3.11 / 295.00 | 2 | 2 |
6 | 8 | 0.20 | 165 | 15.11 | 311 | 775 | 3.88 / 295.78 | 2 | 3 |
Average= | 3.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.32 | 33 | 15.05 | 474 | 235 | 0.24 / 288.20 | 2 | 2 |
2 | 7 | 2008.28 | 31 | 14.81 | 2870 | 1318 | 1.55 / 289.52 | 2 | 2 |
3 | 13 | 1724.72 | 20 | 14.80 | 2533 | 750 | 2.30 / 290.27 | 2 | 2 |
4 | 13 | 1133.60 | 20 | 14.87 | 1816 | 540 | 2.84 / 290.81 | 2 | 3 |
5 | 13 | 535.60 | 20 | 15.00 | 1045 | 313 | 3.16 / 291.12 | 2 | 3 |
6 | 8 | 0.08 | 165 | 15.11 | 309 | 770 | 3.93 / 291.89 | 2 | 3 |
Average= | 3.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.00 | 33 | 15.04 | 469 | 233 | 0.23 / 284.30 | 2 | 2 |
2 | 7 | 2009.44 | 32 | 14.82 | 2866 | 1359 | 1.59 / 285.66 | 2 | 3 |
3 | 13 | 1730.76 | 20 | 14.79 | 2543 | 752 | 2.34 / 286.42 | 2 | 3 |
4 | 13 | 1015.84 | 20 | 14.89 | 1676 | 499 | 2.84 / 286.91 | 2 | 5 |
5 | 13 | 452.40 | 20 | 15.02 | 937 | 281 | 3.12 / 287.20 | 2 | 2 |
6 | 8 | 0.08 | 165 | 15.10 | 309 | 770 | 3.89 / 287.97 | 2 | 4 |
Average= | 3.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.48 | 33 | 15.05 | 459 | 228 | 0.23 / 280.48 | 2 | 2 |
2 | 7 | 2002.64 | 31 | 14.82 | 2853 | 1311 | 1.54 / 281.80 | 2 | 4 |
3 | 13 | 1602.68 | 20 | 14.81 | 2389 | 708 | 2.25 / 282.50 | 2 | 3 |
4 | 13 | 1167.48 | 20 | 14.86 | 1856 | 552 | 2.80 / 283.05 | 2 | 5 |
5 | 13 | 423.88 | 20 | 15.04 | 885 | 266 | 3.06 / 283.32 | 2 | 3 |
6 | 8 | 0.12 | 165 | 15.11 | 301 | 750 | 3.81 / 284.07 | 2 | 3 |
Average= | 3.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.32 | 33 | 15.06 | 468 | 233 | 0.23 / 276.53 | 2 | 2 |
2 | 7 | 2006.56 | 31 | 14.82 | 2866 | 1317 | 1.55 / 277.85 | 2 | 6 |
3 | 13 | 1603.56 | 20 | 14.81 | 2409 | 714 | 2.26 / 278.56 | 2 | 7 |
4 | 13 | 1164.72 | 20 | 14.86 | 1851 | 550 | 2.81 / 279.11 | 2 | 5 |
5 | 13 | 440.00 | 20 | 15.04 | 914 | 275 | 3.09 / 279.39 | 2 | 3 |
6 | 13 | 18.92 | 20 | 15.14 | 337 | 102 | 3.19 / 279.49 | 2 | 2 |
7 | 8 | -0.04 | 165 | 15.10 | 308 | 767 | 3.96 / 280.26 | 2 | 4 |
Average= | 3.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.68 | 33 | 15.06 | 466 | 232 | 0.23 / 272.70 | 2 | 2 |
2 | 7 | 2003.80 | 31 | 14.83 | 2863 | 1316 | 1.55 / 274.01 | 2 | 4 |
3 | 13 | 1622.28 | 20 | 14.82 | 2411 | 715 | 2.26 / 274.73 | 2 | 5 |
4 | 13 | 1077.32 | 20 | 14.88 | 1749 | 521 | 2.78 / 275.25 | 2 | 7 |
5 | 13 | 485.68 | 20 | 15.03 | 978 | 294 | 3.08 / 275.54 | 2 | 3 |
6 | 8 | 0.24 | 165 | 15.12 | 304 | 758 | 3.84 / 276.30 | 2 | 5 |
Average= | 3.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.08 | 33 | 15.07 | 467 | 232 | 0.23 / 268.79 | 2 | 2 |
2 | 7 | 2005.60 | 32 | 14.81 | 2873 | 1362 | 1.59 / 270.15 | 2 | 3 |
3 | 13 | 1735.56 | 20 | 14.79 | 2559 | 757 | 2.35 / 270.91 | 2 | 4 |
4 | 13 | 1121.84 | 20 | 14.88 | 1799 | 535 | 2.89 / 271.44 | 2 | 4 |
5 | 13 | 384.76 | 20 | 15.06 | 834 | 251 | 3.14 / 271.69 | 2 | 3 |
6 | 8 | 0.16 | 165 | 15.11 | 309 | 770 | 3.91 / 272.46 | 2 | 3 |
Average= | 3.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.36 | 33 | 15.06 | 475 | 236 | 0.24 / 264.88 | 2 | 2 |
2 | 7 | 2008.04 | 31 | 14.82 | 2865 | 1316 | 1.55 / 266.20 | 2 | 2 |
3 | 13 | 1503.32 | 20 | 14.83 | 2280 | 676 | 2.23 / 266.87 | 2 | 2 |
4 | 13 | 1097.76 | 20 | 14.87 | 1768 | 526 | 2.75 / 267.40 | 2 | 2 |
5 | 13 | 356.80 | 20 | 15.07 | 807 | 243 | 3.00 / 267.64 | 2 | 2 |
6 | 8 | 0.12 | 165 | 15.13 | 310 | 774 | 3.77 / 268.41 | 2 | 2 |
7 | 14 | 0.12 | 30 | 15.10 | 314 | 142 | 3.91 / 268.56 | 2 | 3 |
Average= | 3.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.20 | 33 | 15.08 | 463 | 230 | 0.23 / 260.90 | 2 | 2 |
2 | 7 | 2006.44 | 31 | 14.81 | 2864 | 1315 | 1.55 / 262.21 | 2 | 2 |
3 | 13 | 1600.52 | 20 | 14.82 | 2398 | 711 | 2.26 / 262.92 | 2 | 2 |
4 | 13 | 1042.08 | 20 | 14.90 | 1702 | 507 | 2.76 / 263.43 | 2 | 2 |
5 | 13 | 481.04 | 20 | 15.04 | 969 | 291 | 3.05 / 263.72 | 2 | 2 |
6 | 8 | 0.04 | 165 | 15.13 | 313 | 781 | 3.84 / 264.50 | 2 | 3 |
7 | 14 | 0.04 | 30 | 15.11 | 313 | 142 | 3.98 / 264.64 | 2 | 10 |
Average= | 3.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.40 | 33 | 15.08 | 468 | 233 | 0.23 / 257.14 | 2 | 2 |
2 | 7 | 2003.40 | 31 | 14.81 | 2863 | 1314 | 1.55 / 258.46 | 2 | 2 |
3 | 13 | 1598.72 | 20 | 14.82 | 2382 | 706 | 2.25 / 259.16 | 2 | 2 |
4 | 13 | 1038.80 | 20 | 14.90 | 1702 | 507 | 2.76 / 259.67 | 2 | 2 |
5 | 13 | 326.40 | 20 | 15.09 | 764 | 231 | 2.99 / 259.90 | 2 | 2 |
6 | 8 | -0.08 | 165 | 15.13 | 306 | 764 | 3.76 / 260.66 | 2 | 6 |
Average= | 3.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.20 | 33 | 15.09 | 479 | 239 | 0.24 / 253.27 | 2 | 2 |
2 | 7 | 2006.88 | 31 | 14.82 | 2865 | 1316 | 1.55 / 254.59 | 2 | 2 |
3 | 13 | 1605.28 | 20 | 14.82 | 2405 | 713 | 2.27 / 255.30 | 2 | 2 |
4 | 13 | 1161.28 | 20 | 14.88 | 1856 | 552 | 2.82 / 255.86 | 2 | 2 |
5 | 13 | 412.72 | 20 | 15.07 | 888 | 268 | 3.09 / 256.12 | 2 | 2 |
6 | 8 | 0.08 | 165 | 15.14 | 315 | 787 | 3.87 / 256.91 | 2 | 2 |
Average= | 3.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.40 | 33 | 15.09 | 482 | 240 | 0.24 / 249.40 | 2 | 2 |
2 | 7 | 2006.88 | 32 | 14.83 | 2870 | 1362 | 1.60 / 250.76 | 2 | 2 |
3 | 13 | 1595.20 | 20 | 14.84 | 2391 | 710 | 2.31 / 251.47 | 2 | 2 |
4 | 13 | 1047.76 | 20 | 14.90 | 1713 | 510 | 2.82 / 251.98 | 2 | 2 |
5 | 13 | 444.16 | 20 | 15.07 | 930 | 280 | 3.10 / 252.26 | 2 | 2 |
6 | 8 | 0.00 | 165 | 15.14 | 311 | 777 | 3.88 / 253.04 | 2 | 4 |
Average= | 3.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.32 | 33 | 15.09 | 467 | 233 | 0.23 / 245.56 | 2 | 2 |
2 | 7 | 2004.52 | 31 | 14.83 | 2863 | 1316 | 1.55 / 246.87 | 2 | 2 |
3 | 13 | 1608.48 | 20 | 14.84 | 2407 | 714 | 2.26 / 247.59 | 2 | 2 |
4 | 13 | 1038.04 | 20 | 14.92 | 1702 | 508 | 2.77 / 248.09 | 2 | 2 |
5 | 13 | 455.24 | 20 | 15.08 | 934 | 282 | 3.05 / 248.38 | 2 | 2 |
6 | 8 | -0.04 | 165 | 15.15 | 312 | 780 | 3.83 / 249.16 | 2 | 5 |
Average= | 3.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.32 | 33 | 15.09 | 472 | 235 | 0.24 / 241.62 | 2 | 2 |
2 | 7 | 2011.16 | 31 | 14.82 | 2877 | 1322 | 1.56 / 242.94 | 2 | 2 |
3 | 13 | 1608.08 | 20 | 14.83 | 2415 | 716 | 2.27 / 243.66 | 2 | 2 |
4 | 13 | 1039.28 | 20 | 14.92 | 1705 | 509 | 2.78 / 244.17 | 2 | 2 |
5 | 13 | 347.28 | 20 | 15.11 | 791 | 239 | 3.02 / 244.40 | 2 | 2 |
6 | 8 | 0.28 | 165 | 15.16 | 311 | 778 | 3.80 / 245.18 | 2 | 3 |
7 | 14 | 0.28 | 30 | 15.13 | 311 | 141 | 3.94 / 245.32 | 2 | 8 |
Average= | 3.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.44 | 33 | 15.11 | 465 | 232 | 0.23 / 237.63 | 2 | 2 |
2 | 7 | 2003.28 | 31 | 14.84 | 2874 | 1322 | 1.55 / 238.95 | 2 | 2 |
3 | 13 | 1595.28 | 20 | 14.84 | 2393 | 710 | 2.26 / 239.66 | 2 | 2 |
4 | 13 | 1169.08 | 20 | 14.89 | 1870 | 557 | 2.82 / 240.22 | 2 | 2 |
5 | 13 | 406.08 | 20 | 15.10 | 884 | 267 | 3.09 / 240.48 | 2 | 2 |
6 | 13 | 46.24 | 20 | 15.19 | 391 | 119 | 3.21 / 240.60 | 2 | 2 |
7 | 8 | -0.04 | 165 | 15.15 | 313 | 782 | 3.99 / 241.38 | 2 | 3 |
Average= | 3.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.24 | 33 | 15.12 | 458 | 229 | 0.23 / 233.55 | 2 | 2 |
2 | 7 | 2007.44 | 31 | 14.85 | 2872 | 1322 | 1.55 / 234.87 | 2 | 2 |
3 | 13 | 1742.56 | 20 | 14.83 | 2586 | 767 | 2.32 / 235.64 | 2 | 2 |
4 | 13 | 1135.60 | 20 | 14.92 | 1832 | 547 | 2.86 / 236.18 | 2 | 2 |
5 | 13 | 536.24 | 20 | 15.06 | 1051 | 317 | 3.18 / 236.50 | 2 | 2 |
6 | 13 | 36.04 | 20 | 15.19 | 369 | 112 | 3.29 / 236.61 | 2 | 2 |
7 | 8 | 0.04 | 165 | 15.16 | 313 | 783 | 4.08 / 237.39 | 2 | 3 |
Average= | 3.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.72 | 32 | 15.12 | 480 | 232 | 0.23 / 229.77 | 2 | 2 |
2 | 7 | 2005.56 | 31 | 14.84 | 2867 | 1319 | 1.55 / 231.09 | 2 | 2 |
3 | 13 | 1595.28 | 20 | 14.85 | 2395 | 711 | 2.26 / 231.80 | 2 | 2 |
4 | 13 | 1039.28 | 20 | 14.93 | 1702 | 508 | 2.77 / 232.31 | 2 | 2 |
5 | 13 | 336.60 | 20 | 15.13 | 779 | 236 | 3.01 / 232.55 | 2 | 2 |
6 | 8 | 0.12 | 165 | 15.17 | 308 | 771 | 3.78 / 233.32 | 2 | 3 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.76 | 32 | 15.13 | 466 | 226 | 0.23 / 225.94 | 2 | 2 |
2 | 7 | 2005.36 | 31 | 14.84 | 2876 | 1323 | 1.55 / 227.26 | 2 | 2 |
3 | 13 | 1590.08 | 20 | 14.85 | 2394 | 711 | 2.26 / 227.97 | 2 | 2 |
4 | 13 | 1030.12 | 20 | 14.94 | 1696 | 507 | 2.77 / 228.48 | 2 | 2 |
5 | 13 | 431.44 | 20 | 15.10 | 920 | 278 | 3.04 / 228.75 | 2 | 2 |
6 | 8 | 0.28 | 165 | 15.17 | 314 | 786 | 3.83 / 229.54 | 2 | 2 |
Average= | 3.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.32 | 32 | 15.13 | 462 | 224 | 0.22 / 222.12 | 2 | 2 |
2 | 7 | 2006.44 | 31 | 14.86 | 2871 | 1323 | 1.55 / 223.44 | 2 | 2 |
3 | 13 | 1604.48 | 20 | 14.85 | 2404 | 714 | 2.26 / 224.15 | 2 | 2 |
4 | 13 | 1181.52 | 20 | 14.89 | 1879 | 560 | 2.82 / 224.71 | 2 | 2 |
5 | 13 | 318.52 | 20 | 15.14 | 753 | 228 | 3.05 / 224.94 | 2 | 2 |
6 | 8 | 0.00 | 165 | 15.17 | 307 | 768 | 3.82 / 225.71 | 2 | 3 |
Average= | 3.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.40 | 32 | 15.13 | 477 | 231 | 0.23 / 218.34 | 2 | 2 |
2 | 7 | 2005.28 | 31 | 14.85 | 2866 | 1319 | 1.55 / 219.66 | 2 | 2 |
3 | 13 | 1608.60 | 20 | 14.85 | 2410 | 716 | 2.27 / 220.38 | 2 | 2 |
4 | 13 | 1051.84 | 20 | 14.94 | 1716 | 513 | 2.78 / 220.89 | 2 | 2 |
5 | 13 | 326.28 | 20 | 15.14 | 757 | 229 | 3.01 / 221.12 | 2 | 2 |
6 | 8 | 0.04 | 165 | 15.19 | 310 | 777 | 3.79 / 221.89 | 2 | 3 |
Average= | 3.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.80 | 32 | 15.14 | 476 | 231 | 0.23 / 214.44 | 2 | 2 |
2 | 7 | 2006.84 | 31 | 14.86 | 2882 | 1328 | 1.56 / 215.77 | 2 | 2 |
3 | 13 | 1599.60 | 20 | 14.86 | 2407 | 715 | 2.27 / 216.49 | 2 | 2 |
4 | 13 | 1165.40 | 20 | 14.92 | 1871 | 558 | 2.83 / 217.05 | 2 | 2 |
5 | 13 | 418.00 | 20 | 15.12 | 896 | 271 | 3.10 / 217.32 | 2 | 2 |
6 | 8 | 0.16 | 165 | 15.19 | 316 | 792 | 3.89 / 218.11 | 2 | 2 |
Average= | 3.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.52 | 32 | 15.14 | 469 | 227 | 0.23 / 210.51 | 2 | 2 |
2 | 7 | 2009.44 | 31 | 14.84 | 2879 | 1324 | 1.55 / 211.84 | 2 | 2 |
3 | 13 | 1604.44 | 20 | 14.86 | 2415 | 718 | 2.27 / 212.55 | 2 | 2 |
4 | 13 | 1155.56 | 20 | 14.92 | 1858 | 554 | 2.82 / 213.11 | 2 | 2 |
5 | 13 | 543.64 | 20 | 15.08 | 1057 | 319 | 3.14 / 213.43 | 2 | 2 |
6 | 8 | 0.04 | 165 | 15.19 | 314 | 787 | 3.93 / 214.21 | 2 | 2 |
Average= | 3.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.64 | 32 | 15.16 | 481 | 233 | 0.23 / 206.65 | 2 | 2 |
2 | 7 | 2005.92 | 31 | 14.87 | 2873 | 1324 | 1.56 / 207.98 | 2 | 2 |
3 | 13 | 1596.24 | 20 | 14.88 | 2402 | 715 | 2.27 / 208.69 | 2 | 2 |
4 | 13 | 1061.48 | 20 | 14.96 | 1732 | 518 | 2.79 / 209.21 | 2 | 2 |
5 | 13 | 474.00 | 20 | 15.12 | 964 | 292 | 3.08 / 209.50 | 2 | 2 |
6 | 8 | 0.04 | 165 | 15.20 | 313 | 785 | 3.87 / 210.28 | 2 | 4 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.44 | 32 | 15.15 | 479 | 232 | 0.23 / 202.71 | 2 | 2 |
2 | 7 | 2008.92 | 31 | 14.85 | 2870 | 1321 | 1.55 / 204.04 | 2 | 2 |
3 | 13 | 1728.80 | 20 | 14.85 | 2560 | 760 | 2.31 / 204.80 | 2 | 2 |
4 | 13 | 1121.12 | 20 | 14.95 | 1801 | 538 | 2.85 / 205.33 | 2 | 2 |
5 | 13 | 519.92 | 20 | 15.11 | 1024 | 309 | 3.16 / 205.64 | 2 | 2 |
6 | 8 | 0.28 | 165 | 15.21 | 308 | 773 | 3.93 / 206.42 | 2 | 2 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.20 | 32 | 15.14 | 480 | 233 | 0.23 / 198.87 | 2 | 2 |
2 | 7 | 2005.56 | 31 | 14.86 | 2866 | 1320 | 1.55 / 200.19 | 2 | 2 |
3 | 13 | 1601.68 | 20 | 14.86 | 2405 | 715 | 2.27 / 200.91 | 2 | 2 |
4 | 13 | 1040.96 | 20 | 14.96 | 1705 | 510 | 2.78 / 201.42 | 2 | 2 |
5 | 13 | 439.60 | 20 | 15.13 | 917 | 277 | 3.06 / 201.70 | 2 | 2 |
6 | 8 | -0.12 | 165 | 15.21 | 313 | 786 | 3.84 / 202.48 | 2 | 3 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.80 | 32 | 15.16 | 478 | 232 | 0.23 / 194.90 | 2 | 2 |
2 | 7 | 2010.44 | 31 | 14.85 | 2882 | 1327 | 1.56 / 196.23 | 2 | 2 |
3 | 13 | 1613.52 | 20 | 14.87 | 2416 | 719 | 2.28 / 196.95 | 2 | 2 |
4 | 13 | 1049.08 | 20 | 14.96 | 1717 | 514 | 2.79 / 197.46 | 2 | 2 |
5 | 13 | 455.36 | 20 | 15.14 | 939 | 284 | 3.08 / 197.74 | 2 | 2 |
6 | 13 | 19.40 | 20 | 15.24 | 342 | 104 | 3.18 / 197.85 | 2 | 2 |
7 | 8 | 0.04 | 165 | 15.21 | 316 | 793 | 3.97 / 198.64 | 2 | 3 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.16 | 32 | 15.17 | 472 | 229 | 0.23 / 190.90 | 2 | 2 |
2 | 7 | 2004.52 | 32 | 14.86 | 2874 | 1367 | 1.60 / 192.26 | 2 | 2 |
3 | 13 | 1597.76 | 20 | 14.89 | 2403 | 716 | 2.31 / 192.98 | 2 | 2 |
4 | 13 | 1026.92 | 20 | 14.99 | 1691 | 507 | 2.82 / 193.49 | 2 | 2 |
5 | 13 | 439.44 | 20 | 15.16 | 925 | 280 | 3.10 / 193.77 | 2 | 2 |
6 | 13 | 17.16 | 20 | 15.26 | 343 | 105 | 3.20 / 193.87 | 2 | 2 |
7 | 8 | -0.04 | 165 | 15.22 | 318 | 799 | 4.00 / 194.67 | 2 | 6 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.04 | 32 | 15.18 | 474 | 230 | 0.23 / 187.03 | 2 | 2 |
2 | 7 | 2005.48 | 31 | 14.87 | 2876 | 1326 | 1.56 / 188.36 | 2 | 2 |
3 | 13 | 1595.96 | 20 | 14.90 | 2396 | 714 | 2.27 / 189.07 | 2 | 2 |
4 | 13 | 1045.28 | 20 | 14.99 | 1713 | 514 | 2.78 / 189.59 | 2 | 2 |
5 | 13 | 454.08 | 20 | 15.17 | 941 | 285 | 3.07 / 189.87 | 2 | 2 |
6 | 8 | 0.08 | 165 | 15.23 | 316 | 794 | 3.86 / 190.67 | 2 | 4 |
Average= | 3.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.84 | 32 | 15.18 | 477 | 232 | 0.23 / 183.18 | 2 | 2 |
2 | 7 | 2005.36 | 31 | 14.87 | 2884 | 1329 | 1.56 / 184.51 | 2 | 2 |
3 | 13 | 1589.48 | 20 | 14.88 | 2386 | 710 | 2.27 / 185.22 | 2 | 2 |
4 | 13 | 1042.32 | 20 | 14.98 | 1710 | 512 | 2.78 / 185.73 | 2 | 2 |
5 | 13 | 443.08 | 20 | 15.16 | 921 | 279 | 3.06 / 186.01 | 2 | 2 |
6 | 8 | -0.04 | 165 | 15.23 | 317 | 797 | 3.86 / 186.80 | 2 | 3 |
Average= | 3.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.60 | 32 | 15.17 | 477 | 232 | 0.23 / 179.28 | 2 | 2 |
2 | 7 | 2006.28 | 31 | 14.87 | 2880 | 1328 | 1.56 / 180.61 | 2 | 2 |
3 | 13 | 1594.52 | 20 | 14.89 | 2404 | 716 | 2.28 / 181.33 | 2 | 2 |
4 | 13 | 1154.32 | 20 | 14.96 | 1848 | 553 | 2.83 / 181.88 | 2 | 2 |
5 | 13 | 402.68 | 20 | 15.18 | 877 | 266 | 3.09 / 182.15 | 2 | 2 |
6 | 8 | 0.16 | 165 | 15.23 | 318 | 799 | 3.89 / 182.94 | 2 | 3 |
Average= | 3.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.80 | 32 | 15.19 | 481 | 234 | 0.23 / 175.33 | 2 | 2 |
2 | 7 | 2003.56 | 31 | 14.88 | 2870 | 1324 | 1.56 / 176.65 | 2 | 2 |
3 | 13 | 1608.92 | 20 | 14.88 | 2405 | 716 | 2.27 / 177.37 | 2 | 2 |
4 | 13 | 1184.84 | 20 | 14.94 | 1885 | 563 | 2.84 / 177.93 | 2 | 2 |
5 | 13 | 564.32 | 20 | 15.12 | 1084 | 328 | 3.16 / 178.26 | 2 | 2 |
6 | 8 | 0.12 | 165 | 15.24 | 315 | 792 | 3.96 / 179.05 | 2 | 4 |
Average= | 3.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.68 | 32 | 15.20 | 490 | 238 | 0.24 / 171.41 | 2 | 2 |
2 | 7 | 2003.20 | 31 | 14.86 | 2872 | 1323 | 1.56 / 172.73 | 2 | 2 |
3 | 13 | 1728.36 | 20 | 14.86 | 2561 | 761 | 2.32 / 173.49 | 2 | 2 |
4 | 13 | 1121.20 | 20 | 14.97 | 1820 | 545 | 2.87 / 174.04 | 2 | 2 |
5 | 13 | 377.00 | 20 | 15.18 | 845 | 257 | 3.12 / 174.30 | 2 | 2 |
6 | 8 | 0.08 | 165 | 15.24 | 318 | 800 | 3.92 / 175.09 | 2 | 7 |
Average= | 3.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.16 | 32 | 15.19 | 484 | 235 | 0.24 / 167.59 | 2 | 2 |
2 | 7 | 2004.36 | 31 | 14.88 | 2864 | 1321 | 1.56 / 168.91 | 2 | 2 |
3 | 13 | 1604.32 | 20 | 14.89 | 2409 | 717 | 2.27 / 169.63 | 2 | 2 |
4 | 13 | 1037.16 | 20 | 15.01 | 1701 | 511 | 2.78 / 170.14 | 2 | 2 |
5 | 13 | 315.16 | 20 | 15.21 | 755 | 230 | 3.01 / 170.37 | 2 | 2 |
6 | 8 | 0.00 | 165 | 15.25 | 320 | 805 | 3.82 / 171.17 | 2 | 4 |
Average= | 3.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.96 | 32 | 15.20 | 491 | 239 | 0.24 / 163.75 | 2 | 2 |
2 | 7 | 2006.44 | 31 | 14.88 | 2876 | 1327 | 1.57 / 165.08 | 2 | 2 |
3 | 13 | 1614.00 | 20 | 14.90 | 2423 | 722 | 2.29 / 165.80 | 2 | 2 |
4 | 13 | 1044.96 | 20 | 15.01 | 1718 | 516 | 2.80 / 166.32 | 2 | 2 |
5 | 13 | 314.40 | 20 | 15.22 | 755 | 230 | 3.03 / 166.55 | 2 | 2 |
6 | 8 | 0.08 | 165 | 15.25 | 320 | 805 | 3.84 / 167.35 | 2 | 6 |
Average= | 3.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.40 | 32 | 15.21 | 498 | 242 | 0.24 / 159.83 | 2 | 2 |
2 | 7 | 2007.76 | 31 | 14.90 | 2874 | 1328 | 1.57 / 161.16 | 2 | 2 |
3 | 13 | 1611.28 | 20 | 14.89 | 2422 | 721 | 2.29 / 161.88 | 2 | 2 |
4 | 13 | 1156.68 | 20 | 14.97 | 1860 | 557 | 2.85 / 162.44 | 2 | 2 |
5 | 13 | 399.40 | 20 | 15.19 | 872 | 265 | 3.11 / 162.70 | 2 | 2 |
6 | 8 | 0.20 | 165 | 15.26 | 322 | 811 | 3.92 / 163.51 | 2 | 3 |
Average= | 3.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.68 | 32 | 15.22 | 479 | 233 | 0.23 / 155.95 | 2 | 2 |
2 | 7 | 2003.48 | 31 | 14.89 | 2876 | 1328 | 1.56 / 157.28 | 2 | 2 |
3 | 13 | 1598.88 | 20 | 14.92 | 2408 | 719 | 2.28 / 157.99 | 2 | 2 |
4 | 13 | 1027.72 | 20 | 15.02 | 1700 | 511 | 2.79 / 158.51 | 2 | 2 |
5 | 13 | 423.20 | 20 | 15.20 | 908 | 276 | 3.07 / 158.78 | 2 | 2 |
6 | 8 | 0.24 | 165 | 15.27 | 321 | 809 | 3.87 / 159.59 | 2 | 2 |
Average= | 3.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.76 | 32 | 15.21 | 485 | 236 | 0.24 / 151.91 | 2 | 2 |
2 | 7 | 2003.20 | 31 | 14.89 | 2874 | 1327 | 1.56 / 153.24 | 2 | 2 |
3 | 13 | 1592.84 | 20 | 14.92 | 2399 | 716 | 2.28 / 153.95 | 2 | 2 |
4 | 13 | 1146.52 | 20 | 14.99 | 1839 | 551 | 2.83 / 154.50 | 2 | 2 |
5 | 13 | 391.44 | 20 | 15.22 | 863 | 263 | 3.09 / 154.77 | 2 | 2 |
6 | 8 | -0.08 | 165 | 15.28 | 318 | 802 | 3.89 / 155.57 | 2 | 4 |
7 | 14 | -0.08 | 30 | 15.27 | 324 | 148 | 4.04 / 155.72 | 2 | 2 |
Average= | 3.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.48 | 32 | 15.21 | 478 | 233 | 0.23 / 148.09 | 2 | 2 |
2 | 7 | 2003.68 | 31 | 14.89 | 2875 | 1327 | 1.56 / 149.42 | 2 | 2 |
3 | 13 | 1588.08 | 20 | 14.91 | 2397 | 715 | 2.27 / 150.13 | 2 | 2 |
4 | 13 | 1035.76 | 20 | 15.03 | 1708 | 513 | 2.79 / 150.64 | 2 | 2 |
5 | 13 | 299.44 | 20 | 15.23 | 739 | 225 | 3.01 / 150.87 | 2 | 2 |
6 | 8 | 0.16 | 165 | 15.27 | 319 | 804 | 3.82 / 151.67 | 2 | 3 |
Average= | 3.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.88 | 32 | 15.22 | 487 | 237 | 0.24 / 144.12 | 2 | 2 |
2 | 7 | 2002.00 | 31 | 14.90 | 2874 | 1328 | 1.56 / 145.44 | 2 | 2 |
3 | 13 | 1593.04 | 20 | 14.92 | 2407 | 718 | 2.28 / 146.16 | 2 | 2 |
4 | 13 | 1027.56 | 20 | 15.03 | 1696 | 510 | 2.79 / 146.67 | 2 | 2 |
5 | 13 | 305.04 | 20 | 15.24 | 748 | 228 | 3.02 / 146.90 | 2 | 2 |
6 | 8 | -0.04 | 165 | 15.27 | 321 | 809 | 3.83 / 147.71 | 2 | 4 |
7 | 14 | -0.04 | 30 | 15.25 | 324 | 148 | 3.98 / 147.86 | 2 | 4 |
Average= | 3.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.72 | 32 | 15.22 | 482 | 235 | 0.23 / 140.12 | 2 | 2 |
2 | 7 | 2002.16 | 31 | 14.90 | 2881 | 1331 | 1.57 / 141.46 | 2 | 2 |
3 | 13 | 1598.88 | 20 | 14.92 | 2412 | 720 | 2.29 / 142.18 | 2 | 2 |
4 | 13 | 1029.68 | 20 | 15.03 | 1707 | 513 | 2.80 / 142.69 | 2 | 2 |
5 | 13 | 300.04 | 20 | 15.25 | 745 | 227 | 3.03 / 142.92 | 2 | 2 |
6 | 8 | -0.12 | 165 | 15.28 | 323 | 814 | 3.84 / 143.73 | 2 | 4 |
7 | 14 | -0.12 | 30 | 15.25 | 324 | 148 | 3.99 / 143.88 | 2 | 5 |
Average= | 3.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.28 | 32 | 15.23 | 484 | 236 | 0.24 / 136.27 | 2 | 2 |
2 | 7 | 2002.28 | 31 | 14.90 | 2885 | 1333 | 1.57 / 137.60 | 2 | 2 |
3 | 13 | 1477.48 | 20 | 14.95 | 2265 | 677 | 2.25 / 138.28 | 2 | 2 |
4 | 13 | 1204.24 | 20 | 14.98 | 1915 | 574 | 2.82 / 138.85 | 2 | 2 |
5 | 13 | 311.36 | 20 | 15.24 | 756 | 230 | 3.05 / 139.08 | 2 | 2 |
6 | 8 | 0.16 | 165 | 15.28 | 321 | 809 | 3.86 / 139.89 | 2 | 4 |
Average= | 3.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.56 | 32 | 15.22 | 479 | 233 | 0.23 / 132.43 | 2 | 2 |
2 | 7 | 2008.52 | 31 | 14.91 | 2880 | 1331 | 1.56 / 133.76 | 2 | 2 |
3 | 13 | 1600.40 | 20 | 14.94 | 2410 | 720 | 2.28 / 134.48 | 2 | 2 |
4 | 13 | 1028.16 | 20 | 15.03 | 1703 | 512 | 2.80 / 134.99 | 2 | 2 |
5 | 13 | 309.48 | 20 | 15.24 | 755 | 230 | 3.03 / 135.22 | 2 | 2 |
6 | 8 | 0.12 | 165 | 15.29 | 322 | 812 | 3.84 / 136.03 | 2 | 3 |
Average= | 3.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.60 | 32 | 15.23 | 478 | 233 | 0.23 / 128.40 | 2 | 2 |
2 | 7 | 2006.88 | 31 | 14.91 | 2871 | 1327 | 1.56 / 129.73 | 2 | 2 |
3 | 13 | 1588.20 | 20 | 14.95 | 2393 | 716 | 2.28 / 130.44 | 2 | 2 |
4 | 13 | 1039.44 | 20 | 15.05 | 1708 | 514 | 2.79 / 130.96 | 2 | 2 |
5 | 13 | 445.32 | 20 | 15.20 | 931 | 283 | 3.07 / 131.24 | 2 | 2 |
6 | 8 | 0.16 | 165 | 15.29 | 318 | 802 | 3.87 / 132.04 | 2 | 3 |
7 | 14 | 0.16 | 30 | 15.26 | 325 | 149 | 4.02 / 132.19 | 2 | 4 |
Average= | 3.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.12 | 32 | 15.23 | 493 | 240 | 0.24 / 124.46 | 2 | 2 |
2 | 7 | 2008.28 | 31 | 14.92 | 2866 | 1326 | 1.57 / 125.79 | 2 | 2 |
3 | 13 | 1733.68 | 20 | 14.91 | 2569 | 766 | 2.33 / 126.56 | 2 | 2 |
4 | 13 | 1133.96 | 20 | 15.03 | 1826 | 549 | 2.88 / 127.10 | 2 | 2 |
5 | 13 | 389.00 | 20 | 15.22 | 852 | 259 | 3.14 / 127.36 | 2 | 2 |
6 | 8 | -0.12 | 165 | 15.28 | 319 | 804 | 3.94 / 128.17 | 2 | 3 |
Average= | 3.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.84 | 32 | 15.25 | 470 | 229 | 0.23 / 120.59 | 2 | 2 |
2 | 7 | 2009.60 | 31 | 14.91 | 2879 | 1331 | 1.56 / 121.92 | 2 | 2 |
3 | 13 | 1596.60 | 20 | 14.95 | 2404 | 719 | 2.28 / 122.64 | 2 | 2 |
4 | 13 | 1157.32 | 20 | 15.00 | 1869 | 561 | 2.84 / 123.20 | 2 | 2 |
5 | 13 | 287.32 | 20 | 15.27 | 724 | 221 | 3.06 / 123.42 | 2 | 2 |
6 | 8 | 0.20 | 165 | 15.30 | 319 | 805 | 3.87 / 124.22 | 2 | 3 |
Average= | 3.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.76 | 31 | 15.23 | 490 | 231 | 0.23 / 116.73 | 2 | 2 |
2 | 3 | 1015.04 | 1 | 15.30 | 1709 | 26 | 0.26 / 116.76 | 2 | 2 |
3 | 7 | 2003.44 | 31 | 14.91 | 2875 | 1329 | 1.59 / 118.09 | 2 | 2 |
4 | 13 | 1595.48 | 20 | 14.94 | 2409 | 720 | 2.31 / 118.81 | 2 | 2 |
5 | 13 | 1035.12 | 20 | 15.05 | 1708 | 514 | 2.82 / 119.32 | 2 | 2 |
6 | 13 | 316.80 | 20 | 15.26 | 764 | 233 | 3.05 / 119.55 | 2 | 2 |
7 | 8 | 0.56 | 165 | 15.30 | 318 | 803 | 3.86 / 120.36 | 2 | 3 |
Average= | 3.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.68 | 32 | 15.23 | 467 | 228 | 0.23 / 112.88 | 2 | 2 |
2 | 10 | 1000.04 | 2 | 15.25 | 1689 | 52 | 0.28 / 112.93 | 2 | 2 |
3 | 3 | 938.56 | -1 | 15.59 | 1 | 0 | 0.05 / 112.93 | 2 | 2 |
4 | 7 | 2002.76 | 31 | 14.91 | 2870 | 1327 | 1.61 / 114.26 | 2 | 2 |
5 | 13 | 1598.84 | 20 | 14.95 | 2405 | 719 | 2.32 / 114.98 | 2 | 2 |
6 | 13 | 1022.28 | 20 | 15.06 | 1690 | 509 | 2.83 / 115.48 | 2 | 2 |
7 | 13 | 296.40 | 20 | 15.26 | 736 | 225 | 3.06 / 115.71 | 2 | 2 |
8 | 8 | 0.16 | 165 | 15.29 | 314 | 792 | 3.85 / 116.50 | 2 | 3 |
Average= | 3.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.96 | 32 | 15.25 | 480 | 234 | 0.23 / 108.90 | 2 | 2 |
2 | 7 | 2009.16 | 31 | 14.92 | 2895 | 1339 | 1.57 / 110.24 | 2 | 2 |
3 | 13 | 1603.96 | 20 | 14.95 | 2415 | 722 | 2.30 / 110.96 | 2 | 2 |
4 | 13 | 1041.20 | 20 | 15.05 | 1711 | 515 | 2.81 / 111.48 | 2 | 2 |
5 | 13 | 309.88 | 20 | 15.26 | 751 | 229 | 3.04 / 111.70 | 2 | 2 |
6 | 8 | 0.20 | 165 | 15.29 | 317 | 800 | 3.84 / 112.50 | 2 | 3 |
7 | 14 | 0.20 | 30 | 15.27 | 320 | 147 | 3.99 / 112.65 | 2 | 4 |
Average= | 3.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.96 | 32 | 15.23 | 483 | 235 | 0.24 / 105.01 | 2 | 2 |
2 | 7 | 2003.24 | 31 | 14.92 | 2878 | 1331 | 1.57 / 106.34 | 2 | 2 |
3 | 13 | 1588.20 | 20 | 14.95 | 2410 | 721 | 2.29 / 107.06 | 2 | 2 |
4 | 13 | 1021.88 | 20 | 15.05 | 1699 | 511 | 2.80 / 107.57 | 2 | 2 |
5 | 13 | 424.00 | 20 | 15.23 | 913 | 278 | 3.08 / 107.85 | 2 | 2 |
6 | 8 | 0.12 | 165 | 15.29 | 323 | 815 | 3.89 / 108.66 | 2 | 4 |
Average= | 3.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.68 | 32 | 15.23 | 479 | 233 | 0.23 / 101.14 | 2 | 2 |
2 | 7 | 2004.08 | 31 | 14.92 | 2868 | 1327 | 1.56 / 102.46 | 2 | 2 |
3 | 13 | 1582.72 | 20 | 14.95 | 2386 | 713 | 2.27 / 103.18 | 2 | 2 |
4 | 13 | 1025.88 | 20 | 15.07 | 1703 | 513 | 2.79 / 103.69 | 2 | 2 |
5 | 13 | 424.60 | 20 | 15.23 | 913 | 278 | 3.06 / 103.97 | 2 | 2 |
6 | 8 | -0.08 | 165 | 15.29 | 319 | 805 | 3.87 / 104.77 | 2 | 3 |
Average= | 3.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.92 | 32 | 15.24 | 480 | 234 | 0.23 / 97.21 | 2 | 2 |
2 | 7 | 2004.80 | 32 | 14.93 | 2886 | 1379 | 1.61 / 98.59 | 2 | 2 |
3 | 13 | 1590.96 | 20 | 14.96 | 2392 | 716 | 2.33 / 99.31 | 2 | 2 |
4 | 13 | 1041.00 | 20 | 15.07 | 1717 | 518 | 2.85 / 99.82 | 2 | 2 |
5 | 13 | 437.24 | 20 | 15.24 | 924 | 282 | 3.13 / 100.11 | 2 | 2 |
6 | 8 | 0.32 | 165 | 15.31 | 316 | 798 | 3.93 / 100.90 | 2 | 5 |
Average= | 3.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.36 | 32 | 15.24 | 476 | 232 | 0.23 / 93.15 | 2 | 2 |
2 | 7 | 2004.04 | 32 | 14.93 | 2874 | 1373 | 1.61 / 94.53 | 2 | 2 |
3 | 13 | 1596.20 | 20 | 14.96 | 2400 | 718 | 2.32 / 95.24 | 2 | 2 |
4 | 13 | 1149.32 | 20 | 15.04 | 1847 | 556 | 2.88 / 95.80 | 2 | 2 |
5 | 13 | 399.92 | 20 | 15.24 | 870 | 265 | 3.14 / 96.07 | 2 | 2 |
6 | 13 | 41.96 | 20 | 15.33 | 384 | 118 | 3.26 / 96.18 | 2 | 2 |
7 | 8 | -0.08 | 165 | 15.29 | 315 | 795 | 4.06 / 96.98 | 2 | 4 |
Average= | 3.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.32 | 31 | 15.24 | 483 | 228 | 0.23 / 89.18 | 2 | 2 |
2 | 7 | 2005.00 | 31 | 14.93 | 2875 | 1331 | 1.56 / 90.51 | 2 | 2 |
3 | 13 | 1594.12 | 20 | 14.97 | 2406 | 720 | 2.28 / 91.23 | 2 | 2 |
4 | 13 | 1144.32 | 20 | 15.05 | 1844 | 555 | 2.83 / 91.79 | 2 | 2 |
5 | 13 | 276.52 | 20 | 15.30 | 709 | 217 | 3.05 / 92.00 | 2 | 2 |
6 | 13 | 23.48 | 20 | 15.36 | 358 | 110 | 3.16 / 92.11 | 2 | 2 |
7 | 8 | 0.08 | 165 | 15.30 | 320 | 808 | 3.97 / 92.92 | 2 | 4 |
Average= | 3.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.64 | 31 | 15.25 | 482 | 228 | 0.23 / 85.14 | 2 | 2 |
2 | 7 | 2003.88 | 31 | 14.92 | 2885 | 1334 | 1.56 / 86.48 | 2 | 2 |
3 | 13 | 1596.04 | 20 | 14.96 | 2406 | 720 | 2.28 / 87.20 | 2 | 2 |
4 | 13 | 1151.88 | 20 | 15.04 | 1854 | 558 | 2.84 / 87.75 | 2 | 2 |
5 | 13 | 399.44 | 20 | 15.24 | 874 | 266 | 3.11 / 88.02 | 2 | 2 |
6 | 13 | 38.40 | 20 | 15.33 | 389 | 119 | 3.23 / 88.14 | 2 | 2 |
7 | 8 | 0.00 | 165 | 15.30 | 322 | 813 | 4.04 / 88.95 | 2 | 4 |
Average= | 3.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.24 | 31 | 15.27 | 468 | 222 | 0.22 / 81.12 | 2 | 2 |
2 | 7 | 2006.60 | 32 | 14.93 | 2882 | 1377 | 1.60 / 82.50 | 2 | 2 |
3 | 13 | 1596.16 | 20 | 14.97 | 2409 | 721 | 2.32 / 83.22 | 2 | 2 |
4 | 13 | 1142.88 | 20 | 15.04 | 1843 | 554 | 2.87 / 83.77 | 2 | 2 |
5 | 13 | 260.72 | 20 | 15.29 | 692 | 212 | 3.09 / 83.99 | 2 | 2 |
6 | 13 | 21.08 | 20 | 15.34 | 360 | 110 | 3.20 / 84.10 | 2 | 2 |
7 | 8 | 0.08 | 165 | 15.30 | 324 | 818 | 4.01 / 84.91 | 2 | 3 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.76 | 31 | 15.26 | 479 | 227 | 0.23 / 77.15 | 2 | 2 |
2 | 7 | 2006.84 | 31 | 14.95 | 2878 | 1334 | 1.56 / 78.49 | 2 | 2 |
3 | 13 | 1599.84 | 20 | 14.98 | 2421 | 725 | 2.29 / 79.21 | 2 | 2 |
4 | 13 | 1037.60 | 20 | 15.08 | 1720 | 519 | 2.80 / 79.73 | 2 | 2 |
5 | 13 | 326.00 | 20 | 15.28 | 780 | 238 | 3.04 / 79.97 | 2 | 2 |
6 | 13 | 31.84 | 20 | 15.35 | 379 | 116 | 3.16 / 80.08 | 2 | 2 |
7 | 8 | 0.00 | 165 | 15.31 | 323 | 816 | 3.98 / 80.90 | 2 | 4 |
Average= | 3.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.08 | 31 | 15.26 | 496 | 235 | 0.23 / 73.13 | 2 | 2 |
2 | 7 | 2003.20 | 31 | 14.95 | 2881 | 1335 | 1.57 / 74.46 | 2 | 2 |
3 | 13 | 1727.16 | 20 | 14.95 | 2558 | 765 | 2.33 / 75.23 | 2 | 2 |
4 | 13 | 1132.12 | 20 | 15.05 | 1843 | 555 | 2.89 / 75.78 | 2 | 2 |
5 | 13 | 269.60 | 20 | 15.30 | 709 | 217 | 3.11 / 76.00 | 2 | 2 |
6 | 13 | 21.36 | 20 | 15.35 | 359 | 110 | 3.22 / 76.11 | 2 | 2 |
7 | 8 | 0.12 | 165 | 15.31 | 323 | 816 | 4.03 / 76.92 | 2 | 4 |
Average= | 3.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.92 | 31 | 15.26 | 494 | 234 | 0.23 / 69.10 | 2 | 2 |
2 | 7 | 2004.16 | 31 | 14.95 | 2876 | 1333 | 1.57 / 70.43 | 2 | 2 |
3 | 13 | 1591.72 | 20 | 14.98 | 2392 | 717 | 2.28 / 71.15 | 2 | 2 |
4 | 13 | 1047.44 | 20 | 15.08 | 1727 | 521 | 2.80 / 71.67 | 2 | 2 |
5 | 13 | 451.24 | 20 | 15.23 | 950 | 289 | 3.09 / 71.96 | 2 | 2 |
6 | 13 | 21.28 | 20 | 15.35 | 359 | 110 | 3.20 / 72.07 | 2 | 2 |
7 | 8 | 0.20 | 165 | 15.31 | 325 | 821 | 4.02 / 72.89 | 2 | 3 |
Average= | 3.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.84 | 31 | 15.29 | 491 | 233 | 0.23 / 65.10 | 2 | 2 |
2 | 7 | 2002.88 | 31 | 14.96 | 2882 | 1337 | 1.57 / 66.44 | 2 | 2 |
3 | 13 | 1590.08 | 19 | 15.00 | 2404 | 685 | 2.25 / 67.13 | 2 | 2 |
4 | 13 | 1146.92 | 19 | 15.06 | 1860 | 532 | 2.79 / 67.66 | 2 | 2 |
5 | 13 | 407.08 | 19 | 15.26 | 905 | 262 | 3.05 / 67.92 | 2 | 2 |
6 | 13 | 18.44 | 19 | 15.36 | 366 | 107 | 3.16 / 68.03 | 2 | 2 |
7 | 8 | -0.08 | 165 | 15.31 | 333 | 841 | 4.00 / 68.87 | 2 | 4 |
Average= | 3.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.72 | 31 | 15.28 | 483 | 229 | 0.23 / 61.29 | 2 | 2 |
2 | 7 | 2004.36 | 32 | 14.94 | 2874 | 1374 | 1.60 / 62.66 | 2 | 2 |
3 | 13 | 1591.16 | 19 | 14.99 | 2398 | 683 | 2.29 / 63.35 | 2 | 2 |
4 | 13 | 1023.48 | 19 | 15.09 | 1694 | 486 | 2.77 / 63.83 | 2 | 2 |
5 | 13 | 317.32 | 19 | 15.29 | 763 | 222 | 2.99 / 64.05 | 2 | 2 |
6 | 8 | 0.20 | 165 | 15.33 | 323 | 817 | 3.81 / 64.87 | 2 | 3 |
Average= | 3.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.96 | 31 | 15.30 | 480 | 228 | 0.23 / 57.36 | 2 | 2 |
2 | 7 | 2004.48 | 31 | 14.95 | 2876 | 1333 | 1.56 / 58.70 | 2 | 2 |
3 | 13 | 1573.04 | 19 | 15.00 | 2376 | 677 | 2.24 / 59.37 | 2 | 2 |
4 | 13 | 1018.60 | 19 | 15.10 | 1693 | 486 | 2.72 / 59.86 | 2 | 2 |
5 | 13 | 431.12 | 19 | 15.26 | 922 | 267 | 2.99 / 60.13 | 2 | 2 |
6 | 13 | 18.12 | 19 | 15.37 | 361 | 105 | 3.10 / 60.23 | 2 | 2 |
7 | 8 | -0.04 | 165 | 15.32 | 328 | 829 | 3.93 / 61.06 | 2 | 4 |
Average= | 3.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.36 | 31 | 15.28 | 483 | 229 | 0.23 / 53.55 | 2 | 2 |
2 | 7 | 2003.08 | 30 | 14.97 | 2890 | 1298 | 1.53 / 54.84 | 2 | 2 |
3 | 13 | 1598.84 | 19 | 15.00 | 2419 | 689 | 2.22 / 55.53 | 2 | 2 |
4 | 13 | 1054.92 | 19 | 15.10 | 1746 | 501 | 2.72 / 56.03 | 2 | 2 |
5 | 13 | 467.00 | 19 | 15.25 | 978 | 283 | 3.00 / 56.32 | 2 | 2 |
6 | 8 | 0.20 | 165 | 15.34 | 323 | 818 | 3.82 / 57.14 | 2 | 3 |
Average= | 3.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.20 | 31 | 15.29 | 475 | 225 | 0.23 / 49.79 | 2 | 2 |
2 | 7 | 2004.24 | 30 | 14.98 | 2890 | 1299 | 1.52 / 51.09 | 2 | 2 |
3 | 13 | 1577.48 | 18 | 15.02 | 2395 | 648 | 2.17 / 51.74 | 2 | 2 |
4 | 13 | 1156.60 | 18 | 15.07 | 1865 | 506 | 2.68 / 52.25 | 2 | 2 |
5 | 13 | 447.76 | 18 | 15.26 | 943 | 259 | 2.94 / 52.50 | 2 | 2 |
6 | 8 | 0.00 | 165 | 15.34 | 321 | 812 | 3.75 / 53.32 | 2 | 4 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.12 | 31 | 15.28 | 490 | 232 | 0.23 / 45.96 | 2 | 2 |
2 | 7 | 2006.64 | 30 | 14.97 | 2887 | 1297 | 1.53 / 47.25 | 2 | 2 |
3 | 13 | 1588.96 | 18 | 15.00 | 2413 | 652 | 2.18 / 47.91 | 2 | 2 |
4 | 13 | 1049.28 | 18 | 15.10 | 1737 | 472 | 2.65 / 48.38 | 2 | 2 |
5 | 13 | 486.20 | 18 | 15.25 | 993 | 273 | 2.92 / 48.65 | 2 | 2 |
6 | 13 | 30.12 | 18 | 15.35 | 376 | 104 | 3.03 / 48.75 | 2 | 2 |
7 | 8 | 0.24 | 165 | 15.33 | 322 | 814 | 3.84 / 49.57 | 2 | 4 |
Average= | 3.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.72 | 31 | 15.29 | 482 | 228 | 0.23 / 42.11 | 2 | 2 |
2 | 3 | 1016.48 | 1 | 15.39 | 1701 | 26 | 0.25 / 42.13 | 2 | 2 |
3 | 7 | 2007.48 | 30 | 14.97 | 2899 | 1302 | 1.56 / 43.43 | 2 | 2 |
4 | 13 | 1593.28 | 18 | 15.02 | 2407 | 651 | 2.21 / 44.08 | 2 | 2 |
5 | 13 | 1158.16 | 18 | 15.09 | 1872 | 508 | 2.72 / 44.59 | 2 | 2 |
6 | 13 | 572.88 | 18 | 15.24 | 1112 | 305 | 3.02 / 44.90 | 2 | 2 |
7 | 8 | 0.00 | 165 | 15.34 | 327 | 828 | 3.85 / 45.73 | 2 | 3 |
Average= | 3.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.44 | 31 | 15.29 | 473 | 224 | 0.22 / 38.35 | 2 | 2 |
2 | 7 | 2006.48 | 30 | 14.98 | 2884 | 1296 | 1.52 / 39.65 | 2 | 2 |
3 | 13 | 1605.48 | 18 | 15.01 | 2422 | 654 | 2.17 / 40.31 | 2 | 2 |
4 | 13 | 1066.88 | 18 | 15.10 | 1762 | 479 | 2.65 / 40.78 | 2 | 2 |
5 | 13 | 496.36 | 18 | 15.26 | 1011 | 278 | 2.93 / 41.06 | 2 | 2 |
6 | 8 | 0.20 | 165 | 15.34 | 322 | 815 | 3.75 / 41.88 | 2 | 3 |
Average= | 3.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.48 | 31 | 15.30 | 475 | 225 | 0.23 / 34.58 | 2 | 2 |
2 | 7 | 2001.72 | 30 | 14.99 | 2862 | 1287 | 1.51 / 35.87 | 2 | 2 |
3 | 13 | 1589.24 | 18 | 15.02 | 2401 | 649 | 2.16 / 36.52 | 2 | 2 |
4 | 13 | 1168.40 | 18 | 15.08 | 1873 | 508 | 2.67 / 37.03 | 2 | 2 |
5 | 13 | 556.88 | 18 | 15.24 | 1078 | 296 | 2.97 / 37.32 | 2 | 2 |
6 | 8 | 0.00 | 165 | 15.35 | 318 | 805 | 3.77 / 38.13 | 2 | 4 |
Average= | 3.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.64 | 31 | 15.29 | 486 | 230 | 0.23 / 30.83 | 2 | 2 |
2 | 7 | 2006.60 | 31 | 14.99 | 2861 | 1329 | 1.56 / 32.15 | 2 | 2 |
3 | 13 | 1592.72 | 18 | 15.04 | 2379 | 644 | 2.20 / 32.80 | 2 | 2 |
4 | 13 | 1159.08 | 18 | 15.09 | 1861 | 505 | 2.71 / 33.30 | 2 | 2 |
5 | 13 | 439.64 | 18 | 15.28 | 926 | 255 | 2.96 / 33.56 | 2 | 2 |
6 | 8 | 0.12 | 165 | 15.35 | 316 | 800 | 3.76 / 34.36 | 2 | 3 |
Average= | 3.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.44 | 31 | 15.30 | 488 | 231 | 0.23 / 27.11 | 2 | 2 |
2 | 7 | 2004.56 | 30 | 15.00 | 2868 | 1291 | 1.52 / 28.40 | 2 | 2 |
3 | 13 | 1601.36 | 18 | 15.03 | 2406 | 651 | 2.17 / 29.05 | 2 | 2 |
4 | 13 | 1040.40 | 18 | 15.12 | 1720 | 468 | 2.64 / 29.52 | 2 | 2 |
5 | 13 | 466.92 | 18 | 15.27 | 967 | 266 | 2.91 / 29.78 | 2 | 2 |
6 | 8 | 0.04 | 165 | 15.35 | 321 | 813 | 3.72 / 30.60 | 2 | 3 |
Average= | 3.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.44 | 31 | 15.30 | 477 | 226 | 0.23 / 23.20 | 2 | 2 |
2 | 7 | 2003.72 | 30 | 15.00 | 2887 | 1299 | 1.53 / 24.50 | 2 | 2 |
3 | 13 | 1600.52 | 18 | 15.03 | 2421 | 655 | 2.18 / 25.15 | 2 | 2 |
4 | 13 | 1168.84 | 18 | 15.11 | 1879 | 511 | 2.69 / 25.66 | 2 | 2 |
5 | 13 | 441.76 | 18 | 15.29 | 934 | 257 | 2.95 / 25.92 | 2 | 2 |
6 | 8 | 0.16 | 165 | 15.36 | 319 | 808 | 3.76 / 26.73 | 2 | 5 |
7 | 14 | 0.16 | 30 | 15.34 | 320 | 147 | 3.90 / 26.88 | 2 | 4 |
Average= | 3.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.68 | 29 | 15.31 | 496 | 220 | 0.22 / 19.44 | 2 | 2 |
2 | 10 | 1001.12 | 2 | 15.31 | 1672 | 51 | 0.27 / 19.49 | 2 | 2 |
3 | 7 | 2005.96 | 30 | 15.00 | 2866 | 1290 | 1.56 / 20.78 | 2 | 2 |
4 | 13 | 1596.88 | 18 | 15.04 | 2392 | 648 | 2.21 / 21.43 | 2 | 2 |
5 | 13 | 1048.36 | 18 | 15.13 | 1726 | 470 | 2.68 / 21.90 | 2 | 2 |
6 | 13 | 481.12 | 18 | 15.28 | 981 | 270 | 2.95 / 22.17 | 2 | 2 |
7 | 8 | 0.04 | 165 | 15.36 | 316 | 801 | 3.75 / 22.97 | 2 | 6 |
Average= | 3.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.92 | 26 | 15.33 | 473 | 189 | 0.19 / 15.60 | 2 | 2 |
2 | 10 | 1047.20 | 3 | 15.29 | 1736 | 80 | 0.27 / 15.68 | 2 | 2 |
3 | 3 | 1025.12 | 1 | 15.37 | 1715 | 26 | 0.29 / 15.71 | 2 | 2 |
4 | 7 | 2013.56 | 30 | 15.01 | 2879 | 1296 | 1.59 / 17.00 | 2 | 2 |
5 | 13 | 1602.48 | 18 | 15.04 | 2412 | 653 | 2.24 / 17.66 | 2 | 2 |
6 | 13 | 1165.60 | 18 | 15.11 | 1867 | 508 | 2.75 / 18.16 | 2 | 2 |
7 | 13 | 431.60 | 18 | 15.31 | 913 | 252 | 3.00 / 18.42 | 2 | 2 |
8 | 8 | -0.12 | 165 | 15.37 | 318 | 806 | 3.81 / 19.22 | 2 | 3 |
Average= | 3.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.92 | 29 | 15.33 | 465 | 207 | 0.21 / 12.32 | 2 | 2 |
2 | 7 | 1514.80 | 31 | 15.17 | 2270 | 1068 | 1.27 / 13.39 | 2 | 2 |
3 | 13 | 1405.20 | 18 | 15.15 | 2151 | 587 | 1.86 / 13.98 | 2 | 2 |
4 | 13 | 988.40 | 18 | 15.19 | 1631 | 446 | 2.31 / 14.42 | 2 | 2 |
5 | 13 | 265.44 | 18 | 15.35 | 691 | 191 | 2.50 / 14.61 | 2 | 2 |
6 | 8 | 0.08 | 165 | 15.38 | 314 | 797 | 3.29 / 15.41 | 2 | 4 |
Average= | 3.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.64 | 29 | 15.32 | 465 | 207 | 0.21 / 8.64 | 2 | 2 |
2 | 3 | 1020.64 | 1 | 15.39 | 1703 | 26 | 0.23 / 8.66 | 2 | 2 |
3 | 7 | 1513.36 | 74 | 15.04 | 2251 | 2505 | 2.74 / 11.17 | 2 | 2 |
4 | 13 | 157.64 | 18 | 15.37 | 545 | 151 | 2.89 / 11.32 | 2 | 2 |
5 | 8 | 0.20 | 165 | 15.37 | 315 | 799 | 3.69 / 12.12 | 2 | 3 |
Average= | 3.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.20 | 28 | 15.33 | 475 | 204 | 0.20 / 4.92 | 2 | 2 |
2 | 10 | 1030.16 | 2 | 15.32 | 1707 | 52 | 0.26 / 4.97 | 2 | 2 |
3 | 7 | 1519.92 | 74 | 15.02 | 2263 | 2515 | 2.77 / 7.49 | 2 | 2 |
4 | 13 | 143.64 | 18 | 15.37 | 528 | 146 | 2.92 / 7.64 | 2 | 2 |
5 | 8 | 0.16 | 165 | 15.37 | 313 | 794 | 3.71 / 8.43 | 2 | 3 |
Average= | 2.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.72 | 24 | 15.48 | 424 | 158 | 0.16 / 1.94 | 2 | 2 |
2 | 10 | 1010.68 | 3 | 15.31 | 1655 | 76 | 0.23 / 2.01 | 2 | 2 |
3 | 10 | 1039.92 | 2 | 15.31 | 1724 | 53 | 0.29 / 2.06 | 2 | 2 |
4 | 3 | 1025.68 | 1 | 15.35 | 1725 | 26 | 0.31 / 2.09 | 2 | 2 |
5 | 7 | 1005.88 | 75 | 15.19 | 1613 | 1838 | 2.15 / 3.93 | 2 | 2 |
6 | 8 | -0.04 | 165 | 15.39 | 311 | 790 | 2.94 / 4.72 | 2 | 4 |
Average= | 2.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 156.76 | 24 | 15.61 | 496 | 186 | 0.19 / 0.19 | 2 | 2 |
2 | 7 | 169.88 | 74 | 15.58 | 507 | 585 | 0.77 / 0.77 | 2 | 2 |
3 | 8 | 0.12 | 240 | 15.55 | 270 | 1008 | 1.78 / 1.78 | 2 | 7 |
Average= | 1.78 (KJ/cycle) |