SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.16 | 30 | 14.97 | 439 | 197 | 0.20 / 596.06 | 3 | 3 |
2 | 7 | 2004.52 | 30 | 14.80 | 3080 | 1368 | 1.56 / 597.43 | 3 | 3 |
3 | 13 | 1584.92 | 18 | 14.80 | 2547 | 679 | 2.24 / 598.11 | 2 | 4 |
4 | 13 | 1034.28 | 18 | 14.86 | 1796 | 480 | 2.72 / 598.59 | 2 | 4 |
5 | 13 | 592.56 | 18 | 14.92 | 1167 | 313 | 3.04 / 598.90 | 2 | 6 |
6 | 13 | 59.16 | 18 | 15.04 | 378 | 102 | 3.14 / 599.00 | 3 | 4 |
7 | 8 | 0.08 | 165 | 15.01 | 289 | 716 | 3.86 / 599.72 | 3 | 9 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.72 | 30 | 14.96 | 440 | 197 | 0.20 / 592.28 | 3 | 3 |
2 | 7 | 2008.84 | 31 | 14.81 | 3092 | 1420 | 1.62 / 593.70 | 3 | 3 |
3 | 13 | 1482.24 | 18 | 14.81 | 2406 | 641 | 2.26 / 594.34 | 2 | 9 |
4 | 13 | 1070.12 | 18 | 14.83 | 1840 | 491 | 2.75 / 594.83 | 2 | 7 |
5 | 13 | 393.76 | 18 | 14.98 | 874 | 236 | 2.99 / 595.07 | 3 | 4 |
6 | 13 | 60.44 | 18 | 15.05 | 373 | 101 | 3.09 / 595.17 | 3 | 5 |
7 | 8 | 0.12 | 165 | 15.02 | 280 | 694 | 3.78 / 595.86 | 3 | 8 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.44 | 30 | 14.99 | 437 | 197 | 0.20 / 588.46 | 3 | 3 |
2 | 7 | 2011.96 | 30 | 14.78 | 3088 | 1369 | 1.57 / 589.83 | 3 | 6 |
3 | 13 | 1603.48 | 18 | 14.80 | 2560 | 682 | 2.25 / 590.51 | 2 | 6 |
4 | 13 | 1035.20 | 18 | 14.85 | 1799 | 481 | 2.73 / 590.99 | 3 | 6 |
5 | 13 | 473.92 | 18 | 14.96 | 999 | 269 | 3.00 / 591.26 | 3 | 4 |
6 | 13 | 88.48 | 18 | 15.05 | 425 | 115 | 3.11 / 591.38 | 3 | 3 |
7 | 8 | 0.04 | 165 | 15.02 | 284 | 704 | 3.82 / 592.08 | 3 | 8 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.48 | 30 | 14.98 | 464 | 209 | 0.21 / 584.64 | 3 | 3 |
2 | 7 | 2004.28 | 30 | 14.80 | 3085 | 1370 | 1.58 / 586.01 | 3 | 3 |
3 | 13 | 1604.28 | 18 | 14.81 | 2561 | 683 | 2.26 / 586.69 | 2 | 5 |
4 | 13 | 1041.80 | 18 | 14.86 | 1808 | 484 | 2.74 / 587.18 | 2 | 7 |
5 | 13 | 480.36 | 18 | 14.97 | 999 | 269 | 3.01 / 587.45 | 3 | 4 |
6 | 13 | 88.32 | 18 | 15.04 | 418 | 113 | 3.13 / 587.56 | 3 | 6 |
7 | 8 | 0.00 | 165 | 15.03 | 284 | 704 | 3.83 / 588.27 | 3 | 12 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.20 | 30 | 14.99 | 437 | 197 | 0.20 / 580.82 | 3 | 3 |
2 | 7 | 2006.20 | 30 | 14.82 | 3082 | 1370 | 1.57 / 582.19 | 3 | 3 |
3 | 13 | 1586.20 | 18 | 14.81 | 2529 | 674 | 2.24 / 582.87 | 2 | 8 |
4 | 13 | 1027.48 | 18 | 14.88 | 1783 | 478 | 2.72 / 583.34 | 2 | 5 |
5 | 13 | 468.68 | 18 | 14.99 | 983 | 265 | 2.98 / 583.61 | 3 | 4 |
6 | 13 | 77.52 | 18 | 15.06 | 415 | 112 | 3.10 / 583.72 | 3 | 4 |
7 | 8 | 0.12 | 165 | 15.04 | 287 | 712 | 3.81 / 584.43 | 3 | 7 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.76 | 30 | 14.98 | 433 | 195 | 0.19 / 576.91 | 3 | 3 |
2 | 7 | 2007.96 | 30 | 14.80 | 3083 | 1369 | 1.56 / 578.28 | 3 | 3 |
3 | 13 | 1723.24 | 18 | 14.78 | 2721 | 724 | 2.29 / 579.01 | 2 | 5 |
4 | 13 | 1144.96 | 18 | 14.84 | 1935 | 517 | 2.80 / 579.52 | 2 | 4 |
5 | 13 | 553.20 | 18 | 14.95 | 1109 | 298 | 3.10 / 579.82 | 3 | 4 |
6 | 13 | 62.92 | 18 | 15.05 | 381 | 103 | 3.21 / 579.93 | 3 | 3 |
7 | 8 | 0.04 | 165 | 15.03 | 282 | 699 | 3.91 / 580.63 | 3 | 9 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.40 | 30 | 14.97 | 450 | 202 | 0.20 / 573.11 | 3 | 3 |
2 | 7 | 2009.36 | 30 | 14.80 | 3087 | 1371 | 1.57 / 574.48 | 3 | 5 |
3 | 13 | 1615.04 | 18 | 14.80 | 2572 | 685 | 2.26 / 575.17 | 2 | 6 |
4 | 13 | 1047.32 | 18 | 14.85 | 1802 | 482 | 2.74 / 575.65 | 3 | 5 |
5 | 13 | 479.80 | 18 | 14.97 | 998 | 269 | 3.01 / 575.92 | 3 | 4 |
6 | 13 | 81.64 | 18 | 15.05 | 414 | 112 | 3.12 / 576.03 | 3 | 3 |
7 | 8 | 0.20 | 165 | 15.02 | 279 | 691 | 3.81 / 576.72 | 3 | 7 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.16 | 30 | 14.99 | 439 | 197 | 0.20 / 569.35 | 3 | 3 |
2 | 7 | 2003.80 | 30 | 14.81 | 3075 | 1366 | 1.56 / 570.71 | 3 | 3 |
3 | 13 | 1478.04 | 18 | 14.83 | 2396 | 640 | 2.20 / 571.35 | 2 | 5 |
4 | 13 | 1069.96 | 18 | 14.85 | 1848 | 494 | 2.70 / 571.85 | 2 | 8 |
5 | 13 | 483.16 | 18 | 14.96 | 1008 | 271 | 2.97 / 572.12 | 3 | 5 |
6 | 13 | 41.84 | 18 | 15.06 | 348 | 94 | 3.06 / 572.21 | 3 | 3 |
7 | 8 | -0.08 | 165 | 15.02 | 281 | 696 | 3.76 / 572.91 | 3 | 6 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 121.72 | 30 | 14.97 | 468 | 210 | 0.21 / 565.43 | 3 | 3 |
2 | 7 | 2003.88 | 30 | 14.81 | 3084 | 1370 | 1.58 / 566.80 | 3 | 3 |
3 | 13 | 1727.52 | 18 | 14.78 | 2718 | 723 | 2.30 / 567.52 | 2 | 8 |
4 | 13 | 1124.32 | 18 | 14.84 | 1916 | 512 | 2.82 / 568.04 | 2 | 6 |
5 | 13 | 541.80 | 18 | 14.95 | 1090 | 293 | 3.11 / 568.33 | 2 | 4 |
6 | 13 | 105.88 | 18 | 15.03 | 446 | 121 | 3.23 / 568.45 | 3 | 5 |
7 | 8 | 0.08 | 165 | 15.02 | 282 | 699 | 3.93 / 569.15 | 3 | 9 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.36 | 30 | 14.97 | 466 | 209 | 0.21 / 561.60 | 3 | 3 |
2 | 7 | 2005.48 | 30 | 14.80 | 3075 | 1365 | 1.57 / 562.97 | 3 | 4 |
3 | 13 | 1609.32 | 18 | 14.80 | 2573 | 685 | 2.26 / 563.65 | 2 | 8 |
4 | 13 | 1051.64 | 18 | 14.85 | 1817 | 486 | 2.75 / 564.14 | 2 | 6 |
5 | 13 | 470.24 | 18 | 14.97 | 993 | 268 | 3.01 / 564.41 | 3 | 5 |
6 | 13 | 80.16 | 18 | 15.05 | 412 | 112 | 3.12 / 564.52 | 3 | 3 |
7 | 8 | 0.08 | 165 | 15.02 | 284 | 704 | 3.83 / 565.22 | 3 | 9 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.92 | 30 | 14.97 | 438 | 197 | 0.20 / 557.63 | 3 | 3 |
2 | 7 | 2002.92 | 30 | 14.83 | 3069 | 1365 | 1.56 / 558.99 | 3 | 4 |
3 | 13 | 1595.08 | 18 | 14.82 | 2557 | 682 | 2.24 / 559.67 | 2 | 6 |
4 | 13 | 1153.88 | 18 | 14.85 | 1964 | 525 | 2.77 / 560.20 | 2 | 8 |
5 | 13 | 700.36 | 18 | 14.92 | 1325 | 356 | 3.13 / 560.55 | 2 | 7 |
6 | 13 | 102.40 | 18 | 15.05 | 448 | 121 | 3.25 / 560.68 | 3 | 6 |
7 | 8 | -0.04 | 165 | 15.03 | 289 | 717 | 3.96 / 561.39 | 3 | 9 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.24 | 30 | 14.97 | 446 | 200 | 0.20 / 553.80 | 3 | 3 |
2 | 7 | 2010.96 | 30 | 14.80 | 3096 | 1375 | 1.57 / 555.17 | 3 | 5 |
3 | 13 | 1606.92 | 18 | 14.81 | 2561 | 683 | 2.26 / 555.86 | 2 | 7 |
4 | 13 | 1054.00 | 18 | 14.86 | 1823 | 488 | 2.75 / 556.34 | 2 | 7 |
5 | 13 | 501.36 | 18 | 14.97 | 1025 | 276 | 3.02 / 556.62 | 3 | 5 |
6 | 13 | 96.40 | 18 | 15.04 | 431 | 117 | 3.14 / 556.74 | 3 | 7 |
7 | 8 | 0.04 | 165 | 15.01 | 279 | 691 | 3.83 / 557.43 | 3 | 5 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.56 | 30 | 15.00 | 435 | 196 | 0.20 / 550.03 | 3 | 3 |
2 | 7 | 2011.36 | 30 | 14.81 | 3091 | 1373 | 1.57 / 551.40 | 3 | 4 |
3 | 13 | 1608.04 | 18 | 14.81 | 2563 | 683 | 2.25 / 552.08 | 2 | 4 |
4 | 13 | 1049.40 | 18 | 14.85 | 1810 | 484 | 2.74 / 552.57 | 2 | 3 |
5 | 13 | 378.56 | 18 | 14.99 | 853 | 230 | 2.97 / 552.80 | 3 | 4 |
6 | 13 | 69.56 | 18 | 15.04 | 390 | 106 | 3.07 / 552.90 | 3 | 4 |
7 | 8 | 0.08 | 165 | 15.03 | 281 | 697 | 3.77 / 553.60 | 3 | 9 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.56 | 30 | 14.97 | 432 | 194 | 0.19 / 546.17 | 3 | 3 |
2 | 7 | 2010.80 | 30 | 14.82 | 3080 | 1369 | 1.56 / 547.54 | 3 | 3 |
3 | 13 | 1617.16 | 18 | 14.81 | 2578 | 687 | 2.25 / 548.23 | 2 | 6 |
4 | 13 | 1185.16 | 18 | 14.83 | 1991 | 531 | 2.78 / 548.76 | 2 | 5 |
5 | 13 | 458.16 | 18 | 14.97 | 969 | 261 | 3.04 / 549.02 | 3 | 4 |
6 | 13 | 90.64 | 18 | 15.04 | 424 | 115 | 3.16 / 549.14 | 3 | 4 |
7 | 8 | 0.16 | 165 | 15.03 | 279 | 692 | 3.85 / 549.83 | 3 | 11 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.08 | 30 | 14.98 | 436 | 196 | 0.20 / 542.26 | 3 | 3 |
2 | 7 | 2008.28 | 30 | 14.81 | 3095 | 1375 | 1.57 / 543.64 | 3 | 5 |
3 | 13 | 1602.88 | 18 | 14.80 | 2566 | 684 | 2.25 / 544.32 | 2 | 4 |
4 | 13 | 1177.40 | 18 | 14.82 | 1993 | 532 | 2.79 / 544.85 | 2 | 5 |
5 | 13 | 573.00 | 18 | 14.94 | 1137 | 306 | 3.09 / 545.16 | 3 | 4 |
6 | 13 | 122.24 | 18 | 15.04 | 469 | 127 | 3.22 / 545.29 | 3 | 4 |
7 | 8 | 0.16 | 165 | 15.02 | 280 | 694 | 3.91 / 545.98 | 3 | 11 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.96 | 30 | 14.98 | 461 | 207 | 0.21 / 538.38 | 3 | 3 |
2 | 7 | 2010.48 | 31 | 14.81 | 3092 | 1420 | 1.63 / 539.80 | 3 | 7 |
3 | 13 | 1619.16 | 18 | 14.80 | 2598 | 692 | 2.32 / 540.49 | 2 | 4 |
4 | 13 | 1057.20 | 18 | 14.86 | 1828 | 489 | 2.81 / 540.98 | 3 | 5 |
5 | 13 | 499.84 | 18 | 14.97 | 1028 | 277 | 3.08 / 541.26 | 3 | 4 |
6 | 13 | 92.04 | 18 | 15.04 | 422 | 114 | 3.20 / 541.37 | 3 | 5 |
7 | 8 | 0.08 | 165 | 15.03 | 281 | 697 | 3.90 / 542.07 | 3 | 12 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.20 | 30 | 14.99 | 441 | 198 | 0.20 / 534.44 | 3 | 3 |
2 | 7 | 2002.68 | 30 | 14.82 | 3078 | 1368 | 1.57 / 535.81 | 3 | 5 |
3 | 13 | 1723.68 | 18 | 14.80 | 2725 | 726 | 2.29 / 536.53 | 2 | 6 |
4 | 13 | 1142.64 | 18 | 14.85 | 1934 | 517 | 2.81 / 537.05 | 2 | 5 |
5 | 13 | 563.28 | 18 | 14.96 | 1124 | 303 | 3.11 / 537.35 | 3 | 4 |
6 | 13 | 72.28 | 18 | 15.05 | 401 | 109 | 3.22 / 537.46 | 3 | 3 |
7 | 8 | 0.12 | 165 | 15.03 | 286 | 709 | 3.93 / 538.17 | 3 | 11 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.16 | 30 | 14.99 | 449 | 202 | 0.20 / 530.51 | 3 | 3 |
2 | 7 | 2004.08 | 30 | 14.82 | 3081 | 1370 | 1.57 / 531.88 | 3 | 4 |
3 | 13 | 1605.56 | 18 | 14.82 | 2571 | 686 | 2.26 / 532.57 | 2 | 6 |
4 | 13 | 1174.60 | 18 | 14.86 | 1991 | 533 | 2.79 / 533.10 | 2 | 6 |
5 | 13 | 584.16 | 18 | 14.95 | 1153 | 310 | 3.10 / 533.41 | 3 | 7 |
6 | 13 | 123.92 | 18 | 15.05 | 474 | 128 | 3.23 / 533.54 | 3 | 4 |
7 | 8 | 0.04 | 165 | 15.04 | 284 | 705 | 3.93 / 534.24 | 3 | 7 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.08 | 30 | 14.97 | 460 | 207 | 0.21 / 526.64 | 3 | 3 |
2 | 7 | 2009.56 | 30 | 14.81 | 3099 | 1377 | 1.58 / 528.01 | 3 | 4 |
3 | 13 | 1607.56 | 18 | 14.82 | 2582 | 689 | 2.27 / 528.70 | 2 | 6 |
4 | 13 | 1166.12 | 18 | 14.84 | 1975 | 528 | 2.80 / 529.23 | 2 | 4 |
5 | 13 | 437.48 | 18 | 14.99 | 946 | 255 | 3.06 / 529.48 | 3 | 4 |
6 | 13 | 74.32 | 18 | 15.06 | 405 | 110 | 3.16 / 529.59 | 3 | 3 |
7 | 8 | 0.00 | 165 | 15.04 | 288 | 715 | 3.88 / 530.31 | 3 | 6 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.80 | 30 | 14.99 | 448 | 201 | 0.20 / 522.68 | 3 | 3 |
2 | 7 | 2005.00 | 30 | 14.82 | 3085 | 1372 | 1.57 / 524.05 | 3 | 3 |
3 | 13 | 1606.40 | 18 | 14.82 | 2583 | 689 | 2.26 / 524.74 | 2 | 6 |
4 | 13 | 1168.56 | 18 | 14.85 | 1981 | 530 | 2.79 / 525.27 | 2 | 4 |
5 | 13 | 574.28 | 18 | 14.96 | 1156 | 311 | 3.10 / 525.58 | 3 | 5 |
6 | 13 | 65.20 | 18 | 15.06 | 399 | 108 | 3.21 / 525.69 | 3 | 4 |
7 | 8 | 0.08 | 165 | 15.03 | 298 | 739 | 3.95 / 526.43 | 3 | 7 |
Average= | 3.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.16 | 30 | 15.00 | 439 | 198 | 0.20 / 518.77 | 3 | 3 |
2 | 7 | 2006.24 | 30 | 14.82 | 3079 | 1369 | 1.57 / 520.14 | 3 | 3 |
3 | 13 | 1589.80 | 18 | 14.82 | 2554 | 681 | 2.25 / 520.82 | 2 | 8 |
4 | 13 | 1161.48 | 18 | 14.85 | 1970 | 527 | 2.77 / 521.35 | 3 | 5 |
5 | 13 | 567.44 | 18 | 14.96 | 1138 | 306 | 3.08 / 521.65 | 3 | 4 |
6 | 13 | 65.92 | 18 | 15.06 | 399 | 108 | 3.19 / 521.76 | 3 | 7 |
7 | 8 | 0.16 | 165 | 15.04 | 289 | 717 | 3.91 / 522.48 | 3 | 12 |
Average= | 3.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.04 | 30 | 14.97 | 436 | 196 | 0.20 / 514.87 | 3 | 3 |
2 | 7 | 2011.04 | 30 | 14.82 | 3092 | 1375 | 1.57 / 516.24 | 3 | 5 |
3 | 13 | 1595.20 | 18 | 14.82 | 2565 | 684 | 2.25 / 516.93 | 2 | 6 |
4 | 13 | 1043.72 | 18 | 14.88 | 1820 | 487 | 2.74 / 517.42 | 2 | 8 |
5 | 13 | 614.32 | 18 | 14.94 | 1211 | 326 | 3.07 / 517.74 | 3 | 4 |
6 | 13 | 68.08 | 18 | 15.07 | 399 | 108 | 3.18 / 517.85 | 3 | 11 |
7 | 8 | 0.16 | 165 | 15.04 | 291 | 722 | 3.90 / 518.57 | 3 | 16 |
Average= | 3.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.04 | 30 | 14.97 | 432 | 194 | 0.19 / 510.90 | 3 | 3 |
2 | 7 | 2012.60 | 31 | 14.80 | 3086 | 1416 | 1.61 / 512.32 | 2 | 4 |
3 | 13 | 1605.68 | 18 | 14.81 | 2563 | 683 | 2.29 / 513.00 | 2 | 5 |
4 | 13 | 1042.44 | 18 | 14.86 | 1806 | 483 | 2.78 / 513.49 | 2 | 4 |
5 | 13 | 477.00 | 18 | 14.98 | 1009 | 272 | 3.05 / 513.76 | 2 | 4 |
6 | 13 | 74.56 | 18 | 15.06 | 411 | 111 | 3.16 / 513.87 | 3 | 4 |
7 | 13 | 16.32 | 18 | 15.06 | 320 | 87 | 3.25 / 513.96 | 3 | 5 |
8 | 8 | -0.04 | 165 | 15.02 | 290 | 719 | 3.97 / 514.67 | 3 | 9 |
Average= | 3.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.16 | 30 | 14.97 | 437 | 196 | 0.20 / 506.83 | 3 | 3 |
2 | 7 | 2008.12 | 31 | 14.81 | 3102 | 1424 | 1.62 / 508.25 | 3 | 6 |
3 | 13 | 1730.60 | 18 | 14.79 | 2747 | 731 | 2.35 / 508.99 | 2 | 5 |
4 | 13 | 1130.68 | 18 | 14.85 | 1925 | 515 | 2.87 / 509.50 | 2 | 7 |
5 | 13 | 549.08 | 18 | 14.95 | 1107 | 298 | 3.16 / 509.80 | 3 | 4 |
6 | 13 | 59.12 | 18 | 15.06 | 386 | 105 | 3.27 / 509.90 | 3 | 3 |
7 | 13 | 17.04 | 18 | 15.06 | 325 | 88 | 3.36 / 509.99 | 3 | 7 |
8 | 8 | 0.08 | 165 | 15.02 | 290 | 719 | 4.08 / 510.71 | 3 | 9 |
Average= | 3.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.52 | 30 | 14.99 | 445 | 200 | 0.20 / 502.90 | 3 | 3 |
2 | 7 | 2005.60 | 30 | 14.82 | 3085 | 1372 | 1.57 / 504.27 | 3 | 6 |
3 | 13 | 1611.92 | 18 | 14.80 | 2586 | 689 | 2.26 / 504.96 | 2 | 7 |
4 | 13 | 1057.48 | 18 | 14.86 | 1832 | 490 | 2.75 / 505.45 | 2 | 6 |
5 | 13 | 490.76 | 18 | 14.98 | 1025 | 276 | 3.03 / 505.73 | 3 | 5 |
6 | 13 | 85.88 | 18 | 15.06 | 422 | 114 | 3.14 / 505.84 | 3 | 3 |
7 | 13 | 22.16 | 18 | 15.05 | 325 | 88 | 3.23 / 505.93 | 3 | 5 |
8 | 8 | 0.04 | 165 | 15.02 | 283 | 701 | 3.93 / 506.63 | 3 | 3 |
Average= | 3.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.28 | 30 | 14.98 | 456 | 205 | 0.20 / 498.98 | 3 | 3 |
2 | 7 | 2007.76 | 30 | 14.81 | 3090 | 1373 | 1.58 / 500.35 | 3 | 5 |
3 | 13 | 1598.00 | 18 | 14.81 | 2559 | 682 | 2.26 / 501.03 | 2 | 7 |
4 | 13 | 1030.68 | 18 | 14.88 | 1796 | 481 | 2.74 / 501.51 | 3 | 4 |
5 | 13 | 468.20 | 18 | 14.98 | 995 | 268 | 3.01 / 501.78 | 3 | 4 |
6 | 13 | 81.56 | 18 | 15.06 | 422 | 114 | 3.12 / 501.90 | 3 | 3 |
7 | 13 | 20.44 | 18 | 15.07 | 326 | 88 | 3.21 / 501.99 | 3 | 5 |
8 | 8 | 0.04 | 165 | 15.03 | 289 | 717 | 3.93 / 502.70 | 3 | 14 |
Average= | 3.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.84 | 30 | 14.98 | 460 | 207 | 0.21 / 495.05 | 3 | 3 |
2 | 7 | 2011.36 | 30 | 14.81 | 3086 | 1371 | 1.58 / 496.42 | 3 | 3 |
3 | 13 | 1601.32 | 18 | 14.80 | 2575 | 686 | 2.26 / 497.10 | 2 | 7 |
4 | 13 | 1044.84 | 18 | 14.87 | 1810 | 484 | 2.75 / 497.59 | 2 | 6 |
5 | 13 | 477.84 | 18 | 14.98 | 1007 | 272 | 3.02 / 497.86 | 3 | 5 |
6 | 13 | 80.08 | 18 | 15.06 | 418 | 113 | 3.13 / 497.97 | 3 | 12 |
7 | 13 | 18.36 | 18 | 15.07 | 319 | 87 | 3.22 / 498.06 | 3 | 18 |
8 | 8 | 0.08 | 165 | 15.02 | 288 | 714 | 3.93 / 498.77 | 3 | 15 |
Average= | 3.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.80 | 30 | 14.97 | 444 | 199 | 0.20 / 491.07 | 3 | 3 |
2 | 7 | 2003.04 | 30 | 14.82 | 3083 | 1371 | 1.57 / 492.44 | 3 | 4 |
3 | 13 | 1729.12 | 18 | 14.80 | 2746 | 732 | 2.30 / 493.17 | 2 | 6 |
4 | 13 | 1133.56 | 18 | 14.85 | 1932 | 516 | 2.82 / 493.69 | 2 | 5 |
5 | 13 | 427.00 | 18 | 15.00 | 938 | 253 | 3.07 / 493.94 | 3 | 3 |
6 | 13 | 60.92 | 18 | 15.08 | 388 | 105 | 3.18 / 494.04 | 3 | 5 |
7 | 13 | 14.88 | 18 | 15.07 | 317 | 86 | 3.26 / 494.13 | 3 | 3 |
8 | 8 | 0.00 | 165 | 15.04 | 286 | 710 | 3.97 / 494.84 | 3 | 7 |
Average= | 3.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.92 | 30 | 14.97 | 442 | 199 | 0.20 / 487.20 | 3 | 3 |
2 | 7 | 2012.64 | 30 | 14.81 | 3099 | 1377 | 1.58 / 488.57 | 3 | 5 |
3 | 13 | 1604.04 | 18 | 14.80 | 2585 | 689 | 2.26 / 489.26 | 2 | 6 |
4 | 13 | 1048.32 | 18 | 14.86 | 1819 | 487 | 2.75 / 489.75 | 2 | 4 |
5 | 13 | 476.60 | 18 | 14.98 | 1007 | 272 | 3.02 / 490.02 | 3 | 6 |
6 | 13 | 77.00 | 18 | 15.06 | 417 | 113 | 3.14 / 490.13 | 3 | 12 |
7 | 8 | 0.08 | 165 | 15.03 | 296 | 734 | 3.87 / 490.87 | 3 | 14 |
Average= | 3.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.12 | 30 | 14.97 | 431 | 194 | 0.19 / 483.27 | 3 | 3 |
2 | 7 | 2011.12 | 31 | 14.81 | 3093 | 1420 | 1.61 / 484.70 | 3 | 3 |
3 | 13 | 1605.24 | 18 | 14.80 | 2561 | 682 | 2.30 / 485.38 | 2 | 8 |
4 | 13 | 1050.00 | 18 | 14.85 | 1816 | 485 | 2.78 / 485.86 | 2 | 7 |
5 | 13 | 616.88 | 18 | 14.92 | 1203 | 323 | 3.10 / 486.19 | 2 | 6 |
6 | 13 | 58.44 | 18 | 15.05 | 385 | 104 | 3.21 / 486.29 | 3 | 4 |
7 | 8 | 0.00 | 165 | 15.02 | 286 | 709 | 3.92 / 487.00 | 3 | 10 |
Average= | 3.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.28 | 30 | 14.98 | 452 | 203 | 0.20 / 479.54 | 3 | 3 |
2 | 7 | 2004.24 | 30 | 14.80 | 3085 | 1370 | 1.57 / 480.91 | 3 | 3 |
3 | 13 | 1492.28 | 18 | 14.82 | 2427 | 647 | 2.22 / 481.56 | 2 | 6 |
4 | 13 | 983.16 | 18 | 14.87 | 1721 | 461 | 2.68 / 482.02 | 2 | 5 |
5 | 13 | 436.12 | 18 | 14.97 | 940 | 253 | 2.93 / 482.27 | 3 | 5 |
6 | 13 | 61.64 | 18 | 15.05 | 385 | 104 | 3.04 / 482.38 | 3 | 3 |
7 | 8 | 0.12 | 165 | 15.02 | 284 | 704 | 3.74 / 483.08 | 3 | 8 |
Average= | 3.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.96 | 30 | 14.97 | 436 | 196 | 0.20 / 475.71 | 3 | 3 |
2 | 7 | 2002.76 | 30 | 14.81 | 3092 | 1374 | 1.57 / 477.08 | 3 | 4 |
3 | 13 | 1595.32 | 18 | 14.82 | 2563 | 684 | 2.25 / 477.76 | 2 | 7 |
4 | 13 | 1049.84 | 18 | 14.86 | 1813 | 485 | 2.74 / 478.25 | 2 | 6 |
5 | 13 | 492.52 | 18 | 14.97 | 1025 | 276 | 3.01 / 478.53 | 3 | 4 |
6 | 13 | 83.80 | 18 | 15.06 | 413 | 112 | 3.13 / 478.64 | 3 | 4 |
7 | 8 | 0.12 | 165 | 15.03 | 283 | 702 | 3.83 / 479.34 | 3 | 6 |
Average= | 3.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.68 | 30 | 15.00 | 458 | 206 | 0.21 / 471.88 | 3 | 3 |
2 | 7 | 2011.28 | 30 | 14.82 | 3093 | 1375 | 1.58 / 473.25 | 3 | 3 |
3 | 13 | 1598.32 | 18 | 14.80 | 2560 | 682 | 2.26 / 473.93 | 2 | 4 |
4 | 13 | 1158.80 | 18 | 14.84 | 1964 | 525 | 2.79 / 474.46 | 2 | 5 |
5 | 13 | 434.96 | 18 | 14.99 | 937 | 253 | 3.04 / 474.71 | 3 | 4 |
6 | 13 | 70.32 | 18 | 15.07 | 390 | 106 | 3.15 / 474.82 | 3 | 3 |
7 | 8 | 0.00 | 165 | 15.04 | 280 | 695 | 3.84 / 475.51 | 3 | 8 |
Average= | 3.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.44 | 30 | 15.00 | 453 | 204 | 0.20 / 468.06 | 3 | 3 |
2 | 7 | 2004.80 | 30 | 14.82 | 3079 | 1369 | 1.57 / 469.43 | 3 | 3 |
3 | 13 | 1490.12 | 18 | 14.84 | 2411 | 644 | 2.22 / 470.08 | 2 | 10 |
4 | 13 | 1083.68 | 18 | 14.85 | 1859 | 497 | 2.71 / 470.57 | 2 | 5 |
5 | 13 | 494.80 | 18 | 14.97 | 1028 | 277 | 2.99 / 470.85 | 2 | 6 |
6 | 13 | 43.44 | 18 | 15.07 | 365 | 99 | 3.09 / 470.95 | 3 | 4 |
7 | 8 | -0.04 | 165 | 15.04 | 290 | 720 | 3.81 / 471.67 | 3 | 7 |
Average= | 3.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.92 | 30 | 14.99 | 463 | 208 | 0.21 / 464.19 | 3 | 3 |
2 | 7 | 2004.48 | 30 | 14.82 | 3085 | 1372 | 1.58 / 465.56 | 3 | 4 |
3 | 13 | 1607.16 | 18 | 14.82 | 2576 | 687 | 2.27 / 466.25 | 2 | 4 |
4 | 13 | 1163.88 | 18 | 14.85 | 1969 | 526 | 2.79 / 466.78 | 2 | 6 |
5 | 13 | 450.40 | 18 | 15.00 | 968 | 261 | 3.05 / 467.04 | 3 | 4 |
6 | 13 | 63.00 | 18 | 15.08 | 391 | 106 | 3.16 / 467.14 | 3 | 6 |
7 | 8 | 0.24 | 165 | 15.05 | 288 | 715 | 3.88 / 467.86 | 4 | 11 |
Average= | 3.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.00 | 30 | 15.02 | 462 | 208 | 0.21 / 460.33 | 3 | 3 |
2 | 7 | 2003.64 | 30 | 14.83 | 3089 | 1374 | 1.58 / 461.70 | 3 | 5 |
3 | 13 | 1602.16 | 18 | 14.83 | 2567 | 685 | 2.27 / 462.39 | 2 | 6 |
4 | 13 | 1049.68 | 18 | 14.88 | 1817 | 487 | 2.75 / 462.87 | 3 | 4 |
5 | 13 | 480.72 | 18 | 15.00 | 1005 | 271 | 3.03 / 463.14 | 3 | 4 |
6 | 13 | 73.32 | 18 | 15.08 | 410 | 111 | 3.14 / 463.26 | 3 | 4 |
7 | 8 | 0.00 | 165 | 15.06 | 293 | 728 | 3.87 / 463.98 | 3 | 8 |
Average= | 3.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.24 | 29 | 15.01 | 466 | 203 | 0.20 / 456.41 | 3 | 3 |
2 | 7 | 2002.80 | 30 | 14.84 | 3089 | 1375 | 1.58 / 457.79 | 3 | 7 |
3 | 13 | 1595.28 | 18 | 14.84 | 2563 | 685 | 2.26 / 458.47 | 2 | 6 |
4 | 13 | 1150.96 | 18 | 14.87 | 1956 | 524 | 2.79 / 459.00 | 2 | 7 |
5 | 13 | 556.80 | 18 | 14.99 | 1125 | 304 | 3.09 / 459.30 | 3 | 5 |
6 | 13 | 25.00 | 18 | 15.10 | 338 | 92 | 3.18 / 459.39 | 3 | 3 |
7 | 8 | 0.00 | 165 | 15.06 | 293 | 728 | 3.91 / 460.12 | 3 | 9 |
Average= | 3.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.12 | 29 | 15.01 | 463 | 202 | 0.20 / 452.47 | 3 | 3 |
2 | 7 | 2007.16 | 31 | 14.83 | 3090 | 1421 | 1.62 / 453.89 | 3 | 4 |
3 | 13 | 1481.92 | 18 | 14.84 | 2412 | 644 | 2.27 / 454.54 | 2 | 5 |
4 | 13 | 1077.84 | 18 | 14.87 | 1863 | 499 | 2.77 / 455.04 | 2 | 8 |
5 | 13 | 645.84 | 18 | 14.95 | 1258 | 339 | 3.10 / 455.38 | 2 | 5 |
6 | 13 | 33.52 | 18 | 15.09 | 353 | 96 | 3.20 / 455.47 | 3 | 4 |
7 | 8 | 0.04 | 165 | 15.05 | 297 | 738 | 3.94 / 456.21 | 3 | 9 |
Average= | 3.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.60 | 29 | 15.00 | 476 | 207 | 0.21 / 448.51 | 3 | 3 |
2 | 7 | 2011.08 | 30 | 14.83 | 3104 | 1381 | 1.59 / 449.89 | 3 | 6 |
3 | 13 | 1738.96 | 18 | 14.81 | 2755 | 734 | 2.32 / 450.62 | 2 | 7 |
4 | 13 | 1037.44 | 18 | 14.90 | 1809 | 485 | 2.81 / 451.11 | 2 | 7 |
5 | 13 | 593.40 | 18 | 14.98 | 1181 | 318 | 3.13 / 451.42 | 3 | 4 |
6 | 13 | 56.08 | 18 | 15.10 | 385 | 105 | 3.23 / 451.53 | 3 | 3 |
7 | 8 | 0.16 | 165 | 15.07 | 299 | 743 | 3.97 / 452.27 | 3 | 9 |
Average= | 3.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.48 | 29 | 15.01 | 476 | 207 | 0.21 / 444.64 | 3 | 3 |
2 | 7 | 2006.24 | 30 | 14.84 | 3090 | 1376 | 1.58 / 446.01 | 3 | 4 |
3 | 13 | 1589.48 | 18 | 14.83 | 2555 | 682 | 2.26 / 446.70 | 2 | 7 |
4 | 13 | 1036.92 | 18 | 14.89 | 1816 | 487 | 2.75 / 447.18 | 2 | 6 |
5 | 13 | 469.28 | 18 | 15.02 | 1008 | 273 | 3.02 / 447.45 | 3 | 4 |
6 | 13 | 32.84 | 18 | 15.11 | 358 | 97 | 3.12 / 447.55 | 3 | 4 |
7 | 8 | 0.04 | 165 | 15.08 | 300 | 746 | 3.87 / 448.30 | 3 | 11 |
Average= | 3.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.96 | 29 | 15.02 | 479 | 209 | 0.21 / 440.68 | 3 | 3 |
2 | 7 | 2010.00 | 30 | 14.83 | 3107 | 1382 | 1.59 / 442.07 | 3 | 3 |
3 | 13 | 1586.68 | 18 | 14.84 | 2555 | 682 | 2.27 / 442.75 | 2 | 5 |
4 | 13 | 1149.48 | 18 | 14.88 | 1957 | 524 | 2.80 / 443.27 | 3 | 6 |
5 | 13 | 558.60 | 18 | 14.98 | 1131 | 305 | 3.10 / 443.58 | 3 | 4 |
6 | 13 | 47.80 | 18 | 15.10 | 377 | 102 | 3.21 / 443.68 | 3 | 3 |
7 | 8 | -0.04 | 165 | 15.06 | 302 | 750 | 3.96 / 444.43 | 3 | 12 |
Average= | 3.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.56 | 29 | 15.01 | 492 | 214 | 0.21 / 436.80 | 3 | 3 |
2 | 7 | 2003.84 | 30 | 14.85 | 3085 | 1374 | 1.59 / 438.18 | 3 | 4 |
3 | 13 | 1608.00 | 18 | 14.84 | 2588 | 691 | 2.28 / 438.87 | 2 | 4 |
4 | 13 | 1032.20 | 18 | 14.90 | 1813 | 486 | 2.77 / 439.36 | 3 | 5 |
5 | 13 | 466.44 | 18 | 15.01 | 1002 | 271 | 3.04 / 439.63 | 3 | 4 |
6 | 13 | 36.68 | 18 | 15.10 | 361 | 98 | 3.13 / 439.72 | 3 | 6 |
7 | 8 | 0.28 | 165 | 15.06 | 302 | 750 | 3.89 / 440.47 | 3 | 11 |
Average= | 3.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.88 | 29 | 15.01 | 471 | 205 | 0.21 / 432.84 | 3 | 3 |
2 | 7 | 2012.04 | 30 | 14.84 | 3102 | 1381 | 1.59 / 434.22 | 3 | 5 |
3 | 13 | 1598.68 | 18 | 14.84 | 2570 | 686 | 2.27 / 434.91 | 2 | 4 |
4 | 13 | 1031.00 | 18 | 14.90 | 1809 | 485 | 2.76 / 435.39 | 2 | 7 |
5 | 13 | 602.84 | 18 | 14.98 | 1199 | 323 | 3.08 / 435.72 | 2 | 4 |
6 | 13 | 54.44 | 18 | 15.09 | 391 | 106 | 3.19 / 435.82 | 3 | 5 |
7 | 8 | -0.08 | 165 | 15.06 | 308 | 765 | 3.95 / 436.59 | 3 | 8 |
Average= | 3.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.48 | 30 | 15.00 | 479 | 216 | 0.22 / 428.98 | 3 | 3 |
2 | 7 | 2012.80 | 30 | 14.83 | 3100 | 1379 | 1.59 / 430.36 | 3 | 4 |
3 | 13 | 1740.40 | 18 | 14.80 | 2766 | 737 | 2.33 / 431.10 | 2 | 4 |
4 | 13 | 1145.16 | 18 | 14.86 | 1949 | 521 | 2.85 / 431.62 | 2 | 8 |
5 | 13 | 444.68 | 18 | 15.00 | 963 | 260 | 3.11 / 431.88 | 2 | 4 |
6 | 8 | 0.08 | 165 | 15.06 | 306 | 760 | 3.87 / 432.64 | 3 | 10 |
Average= | 3.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.56 | 30 | 14.99 | 457 | 206 | 0.21 / 425.09 | 3 | 3 |
2 | 7 | 2005.32 | 30 | 14.82 | 3084 | 1371 | 1.58 / 426.47 | 3 | 5 |
3 | 13 | 1594.20 | 18 | 14.83 | 2548 | 680 | 2.26 / 427.15 | 2 | 6 |
4 | 13 | 1039.56 | 18 | 14.88 | 1813 | 486 | 2.74 / 427.63 | 2 | 5 |
5 | 13 | 460.60 | 18 | 15.00 | 994 | 268 | 3.01 / 427.90 | 3 | 5 |
6 | 13 | 62.80 | 18 | 15.08 | 409 | 111 | 3.12 / 428.01 | 3 | 4 |
7 | 8 | 0.00 | 165 | 15.05 | 303 | 752 | 3.87 / 428.76 | 3 | 10 |
Average= | 3.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.68 | 30 | 14.96 | 479 | 215 | 0.21 / 421.23 | 3 | 3 |
2 | 7 | 2010.40 | 30 | 14.82 | 3083 | 1371 | 1.59 / 422.60 | 3 | 4 |
3 | 13 | 1606.76 | 18 | 14.81 | 2574 | 686 | 2.27 / 423.28 | 2 | 6 |
4 | 13 | 1039.20 | 18 | 14.87 | 1799 | 482 | 2.75 / 423.77 | 2 | 7 |
5 | 13 | 480.76 | 18 | 14.98 | 1016 | 274 | 3.03 / 424.04 | 2 | 6 |
6 | 13 | 34.60 | 18 | 15.08 | 357 | 97 | 3.12 / 424.14 | 3 | 3 |
7 | 8 | 0.08 | 165 | 15.04 | 303 | 752 | 3.88 / 424.89 | 3 | 12 |
Average= | 3.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.24 | 30 | 15.00 | 475 | 214 | 0.21 / 417.38 | 3 | 3 |
2 | 7 | 2007.56 | 30 | 14.82 | 3071 | 1365 | 1.58 / 418.75 | 3 | 4 |
3 | 13 | 1585.68 | 18 | 14.82 | 2533 | 676 | 2.25 / 419.43 | 2 | 4 |
4 | 13 | 1024.12 | 18 | 14.87 | 1792 | 480 | 2.73 / 419.90 | 2 | 7 |
5 | 13 | 447.52 | 18 | 14.99 | 970 | 262 | 3.00 / 420.17 | 3 | 5 |
6 | 13 | 56.36 | 18 | 15.06 | 387 | 105 | 3.10 / 420.27 | 3 | 4 |
7 | 8 | 0.04 | 165 | 15.03 | 299 | 742 | 3.84 / 421.01 | 3 | 11 |
Average= | 3.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.24 | 30 | 14.98 | 482 | 217 | 0.22 / 413.39 | 3 | 3 |
2 | 7 | 2002.96 | 30 | 14.84 | 3088 | 1375 | 1.59 / 414.77 | 3 | 5 |
3 | 13 | 1734.48 | 18 | 14.82 | 2757 | 735 | 2.33 / 415.50 | 2 | 5 |
4 | 13 | 1132.56 | 18 | 14.88 | 1929 | 517 | 2.84 / 416.02 | 2 | 4 |
5 | 13 | 546.84 | 18 | 14.99 | 1112 | 300 | 3.14 / 416.32 | 3 | 5 |
6 | 13 | 47.16 | 18 | 15.09 | 376 | 102 | 3.25 / 416.42 | 3 | 3 |
7 | 8 | 0.08 | 165 | 15.06 | 301 | 748 | 3.99 / 417.17 | 3 | 9 |
Average= | 3.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.44 | 30 | 15.00 | 481 | 216 | 0.22 / 409.44 | 3 | 3 |
2 | 7 | 2004.28 | 30 | 14.84 | 3078 | 1370 | 1.59 / 410.81 | 3 | 4 |
3 | 13 | 1614.00 | 18 | 14.83 | 2579 | 688 | 2.28 / 411.50 | 2 | 8 |
4 | 13 | 1043.68 | 18 | 14.88 | 1817 | 487 | 2.76 / 411.99 | 2 | 5 |
5 | 13 | 617.16 | 18 | 14.96 | 1219 | 328 | 3.09 / 412.32 | 3 | 4 |
6 | 13 | 60.72 | 18 | 15.07 | 402 | 109 | 3.20 / 412.42 | 3 | 4 |
7 | 8 | 0.04 | 165 | 15.04 | 303 | 752 | 3.95 / 413.18 | 3 | 9 |
Average= | 3.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.28 | 30 | 15.00 | 481 | 216 | 0.22 / 405.44 | 3 | 3 |
2 | 7 | 2005.36 | 30 | 14.83 | 3088 | 1374 | 1.59 / 406.82 | 3 | 6 |
3 | 13 | 1719.64 | 18 | 14.82 | 2728 | 728 | 2.32 / 407.54 | 2 | 4 |
4 | 13 | 1132.04 | 18 | 14.88 | 1930 | 517 | 2.83 / 408.06 | 3 | 7 |
5 | 13 | 552.28 | 18 | 14.97 | 1125 | 303 | 3.14 / 408.36 | 2 | 4 |
6 | 13 | 52.48 | 18 | 15.07 | 384 | 104 | 3.24 / 408.47 | 3 | 4 |
7 | 8 | 0.04 | 165 | 15.04 | 305 | 757 | 4.00 / 409.23 | 3 | 11 |
Average= | 3.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.72 | 30 | 14.99 | 467 | 210 | 0.21 / 401.49 | 3 | 3 |
2 | 7 | 2003.32 | 30 | 14.84 | 3080 | 1371 | 1.58 / 402.86 | 3 | 3 |
3 | 13 | 1602.24 | 18 | 14.83 | 2575 | 687 | 2.27 / 403.54 | 2 | 4 |
4 | 13 | 1157.88 | 18 | 14.87 | 1969 | 527 | 2.80 / 404.07 | 2 | 4 |
5 | 13 | 574.60 | 18 | 14.98 | 1152 | 311 | 3.11 / 404.38 | 3 | 4 |
6 | 13 | 53.72 | 18 | 15.08 | 385 | 105 | 3.21 / 404.49 | 3 | 4 |
7 | 8 | 0.00 | 165 | 15.05 | 298 | 740 | 3.95 / 405.23 | 3 | 7 |
Average= | 3.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.60 | 30 | 14.99 | 447 | 201 | 0.20 / 397.62 | 3 | 3 |
2 | 7 | 2003.60 | 30 | 14.84 | 3082 | 1372 | 1.57 / 398.99 | 3 | 4 |
3 | 13 | 1603.76 | 18 | 14.83 | 2556 | 682 | 2.26 / 399.67 | 2 | 8 |
4 | 13 | 1047.44 | 18 | 14.88 | 1821 | 488 | 2.74 / 400.16 | 3 | 8 |
5 | 13 | 473.68 | 18 | 15.00 | 1003 | 271 | 3.01 / 400.43 | 3 | 4 |
6 | 13 | 76.48 | 18 | 15.07 | 418 | 113 | 3.13 / 400.54 | 3 | 4 |
7 | 8 | 0.00 | 165 | 15.04 | 295 | 732 | 3.86 / 401.28 | 3 | 11 |
Average= | 3.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.20 | 30 | 14.99 | 473 | 213 | 0.21 / 393.76 | 3 | 3 |
2 | 7 | 2009.00 | 30 | 14.84 | 3089 | 1375 | 1.59 / 395.13 | 3 | 5 |
3 | 13 | 1593.84 | 18 | 14.83 | 2567 | 685 | 2.27 / 395.82 | 2 | 4 |
4 | 13 | 1049.28 | 18 | 14.88 | 1817 | 487 | 2.76 / 396.31 | 2 | 7 |
5 | 13 | 489.36 | 18 | 14.98 | 1023 | 276 | 3.04 / 396.58 | 3 | 4 |
6 | 13 | 77.84 | 18 | 15.07 | 418 | 113 | 3.15 / 396.69 | 3 | 3 |
7 | 8 | 0.04 | 165 | 15.04 | 291 | 722 | 3.87 / 397.42 | 3 | 9 |
Average= | 3.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.24 | 30 | 15.00 | 429 | 193 | 0.19 / 389.80 | 3 | 3 |
2 | 7 | 2011.68 | 30 | 14.85 | 3095 | 1379 | 1.57 / 391.18 | 3 | 3 |
3 | 13 | 1600.20 | 18 | 14.84 | 2563 | 685 | 2.26 / 391.86 | 2 | 8 |
4 | 13 | 1173.36 | 18 | 14.86 | 1995 | 534 | 2.79 / 392.40 | 2 | 6 |
5 | 13 | 574.64 | 18 | 14.96 | 1153 | 310 | 3.10 / 392.71 | 3 | 3 |
6 | 13 | 64.88 | 18 | 15.07 | 402 | 109 | 3.21 / 392.82 | 3 | 3 |
7 | 8 | -0.04 | 165 | 15.04 | 294 | 730 | 3.94 / 393.55 | 3 | 7 |
Average= | 3.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.44 | 30 | 15.00 | 462 | 208 | 0.21 / 385.95 | 3 | 3 |
2 | 7 | 2002.56 | 30 | 14.84 | 3076 | 1369 | 1.58 / 387.32 | 3 | 3 |
3 | 13 | 1602.08 | 18 | 14.85 | 2555 | 683 | 2.26 / 388.00 | 2 | 4 |
4 | 13 | 1167.04 | 18 | 14.86 | 1963 | 525 | 2.79 / 388.53 | 2 | 7 |
5 | 13 | 445.12 | 18 | 15.01 | 964 | 260 | 3.05 / 388.79 | 3 | 5 |
6 | 13 | 70.56 | 18 | 15.07 | 403 | 109 | 3.16 / 388.90 | 3 | 5 |
7 | 8 | 0.12 | 165 | 15.05 | 286 | 710 | 3.87 / 389.61 | 3 | 10 |
Average= | 3.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.84 | 30 | 14.99 | 467 | 210 | 0.21 / 382.14 | 3 | 3 |
2 | 7 | 2006.28 | 30 | 14.84 | 3083 | 1373 | 1.58 / 383.52 | 3 | 3 |
3 | 13 | 1601.04 | 18 | 14.85 | 2552 | 682 | 2.26 / 384.20 | 2 | 4 |
4 | 13 | 1047.52 | 18 | 14.89 | 1826 | 489 | 2.75 / 384.69 | 3 | 5 |
5 | 13 | 363.64 | 18 | 15.03 | 846 | 229 | 2.98 / 384.92 | 3 | 5 |
6 | 13 | 50.48 | 18 | 15.08 | 369 | 100 | 3.08 / 385.02 | 3 | 4 |
7 | 8 | 0.00 | 165 | 15.05 | 291 | 723 | 3.81 / 385.74 | 3 | 6 |
Average= | 3.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.52 | 30 | 15.00 | 438 | 197 | 0.20 / 378.27 | 3 | 3 |
2 | 7 | 2010.40 | 30 | 14.85 | 3086 | 1375 | 1.57 / 379.65 | 3 | 6 |
3 | 13 | 1606.96 | 18 | 14.83 | 2580 | 689 | 2.26 / 380.34 | 2 | 5 |
4 | 13 | 1055.08 | 18 | 14.89 | 1832 | 491 | 2.75 / 380.83 | 2 | 6 |
5 | 13 | 477.48 | 18 | 15.00 | 1012 | 273 | 3.02 / 381.10 | 3 | 5 |
6 | 13 | 55.96 | 18 | 15.08 | 391 | 106 | 3.13 / 381.21 | 3 | 3 |
7 | 8 | 0.16 | 165 | 15.05 | 293 | 728 | 3.86 / 381.93 | 3 | 10 |
Average= | 3.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.48 | 30 | 15.00 | 461 | 207 | 0.21 / 374.42 | 3 | 3 |
2 | 7 | 2009.20 | 30 | 14.84 | 3090 | 1376 | 1.58 / 375.80 | 2 | 7 |
3 | 13 | 1602.68 | 18 | 14.83 | 2560 | 683 | 2.27 / 376.48 | 2 | 6 |
4 | 13 | 1044.72 | 18 | 14.89 | 1812 | 486 | 2.75 / 376.97 | 2 | 4 |
5 | 13 | 470.36 | 18 | 15.00 | 1002 | 271 | 3.02 / 377.24 | 3 | 4 |
6 | 13 | 65.12 | 18 | 15.08 | 403 | 109 | 3.13 / 377.35 | 3 | 4 |
7 | 8 | 0.08 | 165 | 15.05 | 294 | 730 | 3.86 / 378.08 | 3 | 5 |
Average= | 3.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.84 | 30 | 15.00 | 472 | 212 | 0.21 / 370.56 | 3 | 3 |
2 | 7 | 2010.00 | 30 | 14.86 | 3109 | 1386 | 1.60 / 371.95 | 3 | 4 |
3 | 13 | 1612.32 | 18 | 14.85 | 2582 | 690 | 2.29 / 372.64 | 2 | 7 |
4 | 13 | 1046.64 | 18 | 14.88 | 1825 | 489 | 2.78 / 373.13 | 2 | 4 |
5 | 13 | 478.08 | 18 | 15.01 | 1012 | 273 | 3.05 / 373.40 | 3 | 4 |
6 | 13 | 46.20 | 18 | 15.09 | 364 | 99 | 3.15 / 373.50 | 3 | 4 |
7 | 8 | 0.08 | 165 | 15.06 | 288 | 716 | 3.87 / 374.21 | 3 | 9 |
Average= | 3.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.80 | 30 | 15.01 | 480 | 216 | 0.22 / 366.65 | 3 | 3 |
2 | 7 | 2006.36 | 30 | 14.85 | 3080 | 1372 | 1.59 / 368.02 | 3 | 8 |
3 | 13 | 1608.32 | 18 | 14.84 | 2586 | 691 | 2.28 / 368.71 | 2 | 4 |
4 | 13 | 1180.40 | 18 | 14.87 | 2002 | 536 | 2.81 / 369.25 | 2 | 7 |
5 | 13 | 442.48 | 18 | 15.03 | 963 | 261 | 3.08 / 369.51 | 3 | 4 |
6 | 13 | 64.28 | 18 | 15.10 | 402 | 109 | 3.18 / 369.62 | 3 | 3 |
7 | 8 | 0.08 | 165 | 15.07 | 293 | 729 | 3.91 / 370.35 | 3 | 15 |
Average= | 3.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.64 | 30 | 15.00 | 454 | 204 | 0.20 / 362.77 | 3 | 3 |
2 | 7 | 2002.68 | 30 | 14.85 | 3099 | 1381 | 1.58 / 364.15 | 3 | 4 |
3 | 13 | 1593.64 | 18 | 14.86 | 2569 | 687 | 2.27 / 364.84 | 2 | 8 |
4 | 13 | 1044.32 | 18 | 14.91 | 1817 | 488 | 2.76 / 365.33 | 3 | 5 |
5 | 13 | 470.44 | 18 | 15.01 | 998 | 270 | 3.03 / 365.60 | 2 | 6 |
6 | 13 | 66.44 | 18 | 15.09 | 402 | 109 | 3.14 / 365.71 | 3 | 3 |
7 | 8 | 0.20 | 165 | 15.06 | 294 | 731 | 3.87 / 366.44 | 3 | 11 |
Average= | 3.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.76 | 30 | 15.01 | 442 | 199 | 0.20 / 358.92 | 3 | 3 |
2 | 7 | 2003.52 | 30 | 14.85 | 3086 | 1375 | 1.57 / 360.30 | 3 | 3 |
3 | 13 | 1591.48 | 18 | 14.85 | 2550 | 682 | 2.26 / 360.98 | 2 | 4 |
4 | 13 | 1042.08 | 18 | 14.89 | 1813 | 486 | 2.74 / 361.46 | 2 | 5 |
5 | 13 | 477.28 | 18 | 15.00 | 1011 | 273 | 3.01 / 361.74 | 3 | 4 |
6 | 13 | 70.12 | 18 | 15.08 | 409 | 111 | 3.13 / 361.85 | 3 | 3 |
7 | 8 | 0.08 | 165 | 15.05 | 289 | 718 | 3.84 / 362.57 | 3 | 9 |
Average= | 3.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.44 | 30 | 15.02 | 460 | 207 | 0.21 / 355.03 | 3 | 3 |
2 | 7 | 2005.60 | 30 | 14.84 | 3075 | 1369 | 1.58 / 356.40 | 3 | 6 |
3 | 13 | 1715.80 | 18 | 14.82 | 2727 | 727 | 2.30 / 357.13 | 2 | 7 |
4 | 13 | 1126.00 | 18 | 14.89 | 1928 | 517 | 2.82 / 357.64 | 2 | 4 |
5 | 13 | 413.36 | 18 | 15.03 | 920 | 249 | 3.07 / 357.89 | 3 | 5 |
6 | 13 | 55.96 | 18 | 15.10 | 384 | 104 | 3.17 / 358.00 | 3 | 3 |
7 | 8 | 0.00 | 165 | 15.07 | 292 | 726 | 3.90 / 358.72 | 3 | 7 |
Average= | 3.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.44 | 30 | 15.02 | 466 | 210 | 0.21 / 351.19 | 3 | 3 |
2 | 7 | 2002.76 | 30 | 14.85 | 3081 | 1373 | 1.58 / 352.56 | 3 | 5 |
3 | 13 | 1584.68 | 18 | 14.85 | 2549 | 681 | 2.26 / 353.24 | 2 | 9 |
4 | 13 | 1037.00 | 18 | 14.91 | 1788 | 480 | 2.74 / 353.72 | 2 | 5 |
5 | 13 | 465.56 | 18 | 15.02 | 987 | 267 | 3.01 / 353.99 | 3 | 6 |
6 | 13 | 43.00 | 18 | 15.10 | 375 | 102 | 3.11 / 354.09 | 3 | 4 |
7 | 8 | 0.00 | 165 | 15.07 | 295 | 734 | 3.85 / 354.82 | 3 | 12 |
Average= | 3.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.60 | 30 | 15.03 | 468 | 211 | 0.21 / 347.34 | 3 | 3 |
2 | 7 | 2003.56 | 30 | 14.86 | 3093 | 1379 | 1.59 / 348.72 | 3 | 6 |
3 | 13 | 1603.72 | 18 | 14.86 | 2581 | 690 | 2.28 / 349.41 | 2 | 3 |
4 | 13 | 1038.76 | 18 | 14.92 | 1817 | 488 | 2.77 / 349.90 | 3 | 7 |
5 | 13 | 470.48 | 18 | 15.04 | 997 | 270 | 3.04 / 350.17 | 3 | 4 |
6 | 13 | 38.04 | 18 | 15.12 | 356 | 97 | 3.14 / 350.26 | 3 | 3 |
7 | 8 | -0.08 | 165 | 15.08 | 287 | 714 | 3.85 / 350.98 | 3 | 8 |
Average= | 3.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.28 | 30 | 15.03 | 459 | 207 | 0.21 / 343.53 | 3 | 3 |
2 | 7 | 2003.84 | 30 | 14.87 | 3074 | 1371 | 1.58 / 344.90 | 3 | 6 |
3 | 13 | 1596.80 | 18 | 14.87 | 2549 | 682 | 2.26 / 345.59 | 2 | 8 |
4 | 13 | 1037.12 | 18 | 14.92 | 1799 | 483 | 2.74 / 346.07 | 2 | 6 |
5 | 13 | 477.40 | 18 | 15.03 | 999 | 270 | 3.01 / 346.34 | 3 | 4 |
6 | 13 | 38.12 | 18 | 15.12 | 343 | 93 | 3.11 / 346.43 | 3 | 3 |
7 | 8 | 0.12 | 165 | 15.07 | 280 | 696 | 3.80 / 347.13 | 3 | 17 |
Average= | 3.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.12 | 30 | 15.04 | 455 | 205 | 0.21 / 339.62 | 3 | 3 |
2 | 7 | 2011.04 | 30 | 14.87 | 3101 | 1383 | 1.59 / 341.00 | 3 | 6 |
3 | 13 | 1739.20 | 18 | 14.85 | 2760 | 738 | 2.33 / 341.74 | 2 | 6 |
4 | 13 | 1149.48 | 18 | 14.90 | 1954 | 524 | 2.85 / 342.26 | 2 | 7 |
5 | 13 | 427.76 | 18 | 15.05 | 930 | 252 | 3.10 / 342.52 | 3 | 4 |
6 | 13 | 32.76 | 18 | 15.12 | 345 | 94 | 3.20 / 342.61 | 3 | 4 |
7 | 8 | 0.12 | 165 | 15.09 | 287 | 715 | 3.91 / 343.32 | 3 | 10 |
Average= | 3.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.84 | 30 | 15.04 | 466 | 210 | 0.21 / 335.74 | 3 | 3 |
2 | 7 | 2005.28 | 30 | 14.87 | 3085 | 1376 | 1.59 / 337.12 | 3 | 4 |
3 | 13 | 1733.32 | 18 | 14.85 | 2750 | 735 | 2.32 / 337.86 | 2 | 6 |
4 | 13 | 1029.12 | 18 | 14.92 | 1787 | 480 | 2.80 / 338.33 | 2 | 4 |
5 | 13 | 464.52 | 18 | 15.03 | 981 | 265 | 3.07 / 338.60 | 3 | 5 |
6 | 13 | 70.32 | 18 | 15.11 | 401 | 109 | 3.18 / 338.71 | 3 | 3 |
7 | 8 | 0.04 | 165 | 15.09 | 283 | 705 | 3.88 / 339.41 | 3 | 6 |
Average= | 3.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.64 | 30 | 15.04 | 457 | 206 | 0.21 / 331.84 | 3 | 3 |
2 | 7 | 2005.56 | 30 | 14.89 | 3089 | 1380 | 1.59 / 333.22 | 3 | 6 |
3 | 13 | 1611.32 | 18 | 14.88 | 2585 | 692 | 2.28 / 333.91 | 2 | 7 |
4 | 13 | 1174.56 | 18 | 14.91 | 1992 | 535 | 2.81 / 334.45 | 2 | 6 |
5 | 13 | 454.64 | 18 | 15.04 | 968 | 262 | 3.08 / 334.71 | 3 | 4 |
6 | 13 | 40.68 | 18 | 15.13 | 359 | 98 | 3.17 / 334.81 | 3 | 4 |
7 | 8 | 0.12 | 165 | 15.09 | 292 | 727 | 3.90 / 335.53 | 3 | 9 |
Average= | 3.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.76 | 30 | 15.04 | 452 | 204 | 0.20 / 328.05 | 3 | 3 |
2 | 7 | 2009.60 | 30 | 14.88 | 3089 | 1379 | 1.58 / 329.43 | 3 | 3 |
3 | 13 | 1608.76 | 18 | 14.89 | 2565 | 687 | 2.27 / 330.12 | 2 | 4 |
4 | 13 | 1044.60 | 18 | 14.93 | 1796 | 483 | 2.75 / 330.60 | 2 | 6 |
5 | 13 | 359.60 | 18 | 15.08 | 815 | 221 | 2.97 / 330.82 | 3 | 4 |
6 | 13 | 45.20 | 18 | 15.14 | 356 | 97 | 3.07 / 330.92 | 3 | 4 |
7 | 8 | 0.00 | 165 | 15.10 | 286 | 713 | 3.78 / 331.63 | 3 | 7 |
Average= | 3.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.36 | 30 | 15.04 | 468 | 211 | 0.21 / 324.15 | 3 | 3 |
2 | 7 | 2010.88 | 31 | 14.89 | 3097 | 1430 | 1.64 / 325.58 | 3 | 5 |
3 | 13 | 1613.28 | 18 | 14.88 | 2577 | 690 | 2.33 / 326.27 | 2 | 8 |
4 | 13 | 1174.28 | 18 | 14.91 | 1972 | 529 | 2.86 / 326.80 | 2 | 6 |
5 | 13 | 442.96 | 18 | 15.05 | 947 | 257 | 3.12 / 327.06 | 3 | 4 |
6 | 13 | 32.80 | 18 | 15.14 | 335 | 91 | 3.21 / 327.15 | 3 | 5 |
7 | 8 | 0.12 | 165 | 15.11 | 281 | 701 | 3.91 / 327.85 | 3 | 10 |
Average= | 3.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.32 | 30 | 15.03 | 472 | 213 | 0.21 / 320.27 | 3 | 3 |
2 | 7 | 2008.48 | 30 | 14.87 | 3095 | 1381 | 1.59 / 321.65 | 3 | 3 |
3 | 13 | 1608.64 | 18 | 14.87 | 2584 | 692 | 2.29 / 322.34 | 2 | 4 |
4 | 13 | 1046.32 | 18 | 14.94 | 1816 | 488 | 2.77 / 322.83 | 2 | 7 |
5 | 13 | 486.24 | 18 | 15.03 | 1020 | 276 | 3.05 / 323.11 | 3 | 4 |
6 | 13 | 35.76 | 18 | 15.12 | 356 | 97 | 3.15 / 323.21 | 3 | 4 |
7 | 8 | 0.00 | 165 | 15.10 | 295 | 735 | 3.88 / 323.94 | 3 | 10 |
Average= | 3.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.60 | 30 | 15.07 | 472 | 213 | 0.21 / 316.24 | 3 | 3 |
2 | 7 | 2003.08 | 30 | 14.88 | 3093 | 1381 | 1.59 / 317.62 | 3 | 5 |
3 | 13 | 1595.32 | 18 | 14.88 | 2568 | 688 | 2.28 / 318.31 | 2 | 6 |
4 | 13 | 1153.68 | 18 | 14.91 | 1970 | 529 | 2.81 / 318.83 | 2 | 6 |
5 | 13 | 703.92 | 18 | 14.99 | 1339 | 361 | 3.17 / 319.20 | 2 | 4 |
6 | 13 | 41.68 | 18 | 15.13 | 372 | 101 | 3.27 / 319.30 | 3 | 3 |
7 | 8 | 0.04 | 165 | 15.10 | 306 | 762 | 4.04 / 320.06 | 3 | 10 |
Average= | 3.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.28 | 30 | 15.06 | 467 | 211 | 0.21 / 312.39 | 3 | 3 |
2 | 7 | 2005.32 | 30 | 14.87 | 3088 | 1378 | 1.59 / 313.76 | 3 | 6 |
3 | 13 | 1607.96 | 18 | 14.87 | 2573 | 689 | 2.28 / 314.45 | 2 | 7 |
4 | 13 | 1161.92 | 18 | 14.91 | 1979 | 531 | 2.81 / 314.98 | 2 | 4 |
5 | 13 | 545.72 | 18 | 15.02 | 1112 | 301 | 3.11 / 315.28 | 3 | 4 |
6 | 8 | 0.08 | 165 | 15.11 | 297 | 740 | 3.85 / 316.02 | 3 | 10 |
Average= | 3.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.28 | 30 | 15.06 | 468 | 211 | 0.21 / 308.64 | 3 | 3 |
2 | 7 | 2004.96 | 30 | 14.87 | 3088 | 1378 | 1.59 / 310.01 | 3 | 3 |
3 | 13 | 1583.56 | 18 | 14.89 | 2533 | 679 | 2.27 / 310.69 | 2 | 5 |
4 | 13 | 1015.00 | 18 | 14.95 | 1772 | 477 | 2.74 / 311.17 | 2 | 6 |
5 | 13 | 459.80 | 18 | 15.06 | 986 | 267 | 3.01 / 311.44 | 3 | 6 |
6 | 8 | 0.20 | 165 | 15.13 | 296 | 739 | 3.75 / 312.17 | 3 | 4 |
Average= | 3.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.16 | 30 | 15.07 | 466 | 211 | 0.21 / 304.66 | 3 | 3 |
2 | 7 | 2008.56 | 31 | 14.88 | 3095 | 1428 | 1.64 / 306.09 | 3 | 4 |
3 | 13 | 1595.84 | 18 | 14.88 | 2574 | 689 | 2.33 / 306.78 | 2 | 6 |
4 | 13 | 1043.40 | 18 | 14.94 | 1820 | 489 | 2.82 / 307.27 | 2 | 6 |
5 | 13 | 599.72 | 18 | 15.02 | 1187 | 321 | 3.14 / 307.59 | 3 | 4 |
6 | 13 | 22.56 | 18 | 15.15 | 338 | 92 | 3.23 / 307.68 | 3 | 8 |
7 | 8 | 0.04 | 165 | 15.11 | 298 | 743 | 3.97 / 308.42 | 3 | 11 |
Average= | 3.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.92 | 30 | 15.07 | 460 | 208 | 0.21 / 300.88 | 3 | 3 |
2 | 7 | 2011.88 | 30 | 14.89 | 3101 | 1385 | 1.59 / 302.26 | 3 | 3 |
3 | 13 | 1613.80 | 18 | 14.88 | 2582 | 692 | 2.28 / 302.95 | 2 | 4 |
4 | 13 | 1047.52 | 18 | 14.93 | 1810 | 486 | 2.77 / 303.44 | 2 | 7 |
5 | 13 | 478.20 | 18 | 15.05 | 1009 | 273 | 3.04 / 303.71 | 3 | 5 |
6 | 8 | 0.16 | 165 | 15.12 | 296 | 738 | 3.78 / 304.45 | 3 | 7 |
Average= | 3.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.12 | 30 | 15.07 | 453 | 205 | 0.20 / 297.14 | 3 | 3 |
2 | 7 | 2006.96 | 30 | 14.88 | 3089 | 1379 | 1.58 / 298.52 | 3 | 4 |
3 | 13 | 1584.56 | 18 | 14.90 | 2535 | 680 | 2.26 / 299.20 | 2 | 7 |
4 | 13 | 1033.56 | 18 | 14.95 | 1791 | 482 | 2.75 / 299.68 | 2 | 5 |
5 | 13 | 467.08 | 18 | 15.06 | 985 | 267 | 3.01 / 299.94 | 3 | 4 |
6 | 8 | 0.24 | 165 | 15.12 | 290 | 723 | 3.74 / 300.67 | 3 | 7 |
Average= | 3.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.68 | 30 | 15.07 | 454 | 205 | 0.21 / 293.33 | 3 | 3 |
2 | 7 | 2010.36 | 30 | 14.88 | 3099 | 1383 | 1.59 / 294.71 | 3 | 4 |
3 | 13 | 1726.76 | 18 | 14.86 | 2729 | 730 | 2.32 / 295.44 | 2 | 6 |
4 | 13 | 1120.76 | 18 | 14.93 | 1923 | 517 | 2.84 / 295.96 | 2 | 8 |
5 | 13 | 414.44 | 18 | 15.08 | 912 | 248 | 3.08 / 296.21 | 3 | 6 |
6 | 8 | 0.08 | 165 | 15.13 | 290 | 724 | 3.81 / 296.93 | 3 | 10 |
Average= | 3.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.48 | 30 | 15.08 | 452 | 204 | 0.20 / 289.36 | 3 | 3 |
2 | 7 | 2008.00 | 30 | 14.88 | 3076 | 1373 | 1.58 / 290.74 | 3 | 5 |
3 | 13 | 1603.04 | 18 | 14.88 | 2567 | 688 | 2.27 / 291.42 | 2 | 5 |
4 | 13 | 1171.92 | 18 | 14.92 | 1979 | 531 | 2.80 / 291.96 | 2 | 7 |
5 | 13 | 568.08 | 18 | 15.04 | 1138 | 308 | 3.10 / 292.26 | 3 | 4 |
6 | 8 | 0.16 | 165 | 15.13 | 292 | 729 | 3.83 / 292.99 | 3 | 6 |
7 | 14 | 0.16 | 30 | 15.11 | 292 | 132 | 3.97 / 293.12 | 3 | 6 |
Average= | 3.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.48 | 30 | 15.10 | 462 | 209 | 0.21 / 285.44 | 3 | 3 |
2 | 7 | 2005.56 | 30 | 14.90 | 3093 | 1383 | 1.59 / 286.82 | 3 | 3 |
3 | 13 | 1591.68 | 18 | 14.89 | 2549 | 683 | 2.28 / 287.51 | 2 | 5 |
4 | 13 | 1025.36 | 18 | 14.96 | 1785 | 481 | 2.76 / 287.99 | 2 | 5 |
5 | 13 | 585.88 | 18 | 15.04 | 1163 | 315 | 3.07 / 288.30 | 3 | 6 |
6 | 8 | 0.04 | 165 | 15.13 | 291 | 726 | 3.80 / 289.03 | 3 | 7 |
7 | 14 | 0.04 | 30 | 15.11 | 288 | 131 | 3.93 / 289.16 | 4 | 10 |
Average= | 3.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.84 | 30 | 15.09 | 461 | 209 | 0.21 / 281.58 | 3 | 3 |
2 | 7 | 2004.52 | 30 | 14.90 | 3085 | 1379 | 1.59 / 282.96 | 3 | 4 |
3 | 13 | 1729.24 | 18 | 14.87 | 2725 | 729 | 2.32 / 283.69 | 2 | 3 |
4 | 13 | 1122.92 | 18 | 14.95 | 1912 | 515 | 2.83 / 284.20 | 2 | 6 |
5 | 13 | 533.60 | 18 | 15.06 | 1084 | 294 | 3.13 / 284.50 | 3 | 5 |
6 | 8 | 0.16 | 165 | 15.15 | 294 | 735 | 3.86 / 285.23 | 3 | 9 |
Average= | 3.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.52 | 30 | 15.09 | 466 | 211 | 0.21 / 277.80 | 3 | 3 |
2 | 7 | 2009.76 | 30 | 14.91 | 3088 | 1381 | 1.59 / 279.18 | 3 | 3 |
3 | 13 | 1599.28 | 18 | 14.90 | 2557 | 686 | 2.28 / 279.86 | 2 | 10 |
4 | 13 | 1044.92 | 18 | 14.97 | 1820 | 490 | 2.77 / 280.36 | 2 | 5 |
5 | 13 | 476.40 | 18 | 15.08 | 1006 | 273 | 3.04 / 280.63 | 3 | 4 |
6 | 8 | 0.16 | 165 | 15.15 | 297 | 742 | 3.78 / 281.37 | 3 | 9 |
Average= | 3.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.00 | 30 | 15.10 | 455 | 206 | 0.21 / 274.07 | 3 | 3 |
2 | 7 | 2004.48 | 30 | 14.91 | 3089 | 1382 | 1.59 / 275.46 | 3 | 3 |
3 | 13 | 1491.68 | 18 | 14.92 | 2424 | 651 | 2.24 / 276.11 | 2 | 6 |
4 | 13 | 1091.60 | 18 | 14.95 | 1883 | 507 | 2.75 / 276.61 | 2 | 5 |
5 | 13 | 381.40 | 18 | 15.11 | 867 | 236 | 2.98 / 276.85 | 3 | 5 |
6 | 8 | 0.08 | 165 | 15.15 | 295 | 737 | 3.72 / 277.59 | 3 | 9 |
Average= | 3.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.48 | 30 | 15.09 | 485 | 220 | 0.22 / 270.29 | 3 | 3 |
2 | 7 | 2007.44 | 31 | 14.90 | 3089 | 1427 | 1.65 / 271.72 | 3 | 3 |
3 | 13 | 1597.84 | 18 | 14.89 | 2550 | 683 | 2.33 / 272.40 | 2 | 9 |
4 | 13 | 1041.80 | 18 | 14.95 | 1816 | 489 | 2.82 / 272.89 | 2 | 5 |
5 | 13 | 353.44 | 18 | 15.12 | 837 | 228 | 3.05 / 273.12 | 3 | 5 |
6 | 8 | 0.12 | 165 | 15.16 | 299 | 748 | 3.79 / 273.87 | 3 | 6 |
Average= | 3.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.08 | 30 | 15.11 | 460 | 209 | 0.21 / 266.27 | 3 | 3 |
2 | 7 | 2005.96 | 31 | 14.90 | 3072 | 1419 | 1.63 / 267.69 | 3 | 8 |
3 | 13 | 1585.64 | 18 | 14.90 | 2543 | 682 | 2.31 / 268.37 | 2 | 7 |
4 | 13 | 1149.56 | 18 | 14.94 | 1966 | 529 | 2.84 / 268.90 | 2 | 6 |
5 | 13 | 548.80 | 18 | 15.06 | 1118 | 303 | 3.14 / 269.20 | 2 | 4 |
6 | 13 | 38.88 | 18 | 15.18 | 367 | 100 | 3.24 / 269.30 | 3 | 3 |
7 | 8 | 0.12 | 165 | 15.15 | 308 | 770 | 4.01 / 270.07 | 3 | 8 |
Average= | 3.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.64 | 30 | 15.10 | 472 | 214 | 0.21 / 262.30 | 3 | 3 |
2 | 7 | 2009.76 | 31 | 14.89 | 3096 | 1429 | 1.64 / 263.73 | 3 | 3 |
3 | 13 | 1592.60 | 18 | 14.90 | 2554 | 685 | 2.33 / 264.41 | 2 | 7 |
4 | 13 | 1157.36 | 18 | 14.94 | 1972 | 530 | 2.86 / 264.94 | 2 | 6 |
5 | 13 | 547.44 | 18 | 15.08 | 1110 | 301 | 3.16 / 265.24 | 3 | 7 |
6 | 13 | 22.96 | 18 | 15.19 | 332 | 91 | 3.25 / 265.33 | 3 | 4 |
7 | 8 | -0.04 | 165 | 15.15 | 291 | 727 | 3.98 / 266.06 | 3 | 12 |
Average= | 3.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.88 | 30 | 15.11 | 478 | 217 | 0.22 / 258.39 | 3 | 3 |
2 | 7 | 2011.76 | 30 | 14.90 | 3105 | 1388 | 1.60 / 259.77 | 3 | 3 |
3 | 13 | 1593.64 | 18 | 14.91 | 2575 | 691 | 2.30 / 260.47 | 2 | 7 |
4 | 13 | 1039.52 | 18 | 14.97 | 1822 | 491 | 2.79 / 260.96 | 3 | 6 |
5 | 13 | 471.12 | 18 | 15.09 | 1008 | 274 | 3.06 / 261.23 | 3 | 5 |
6 | 13 | 32.52 | 18 | 15.19 | 360 | 98 | 3.16 / 261.33 | 3 | 5 |
7 | 8 | 0.12 | 165 | 15.16 | 302 | 755 | 3.91 / 262.08 | 3 | 8 |
Average= | 3.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.92 | 29 | 15.11 | 485 | 213 | 0.21 / 254.43 | 3 | 3 |
2 | 7 | 2010.36 | 30 | 14.90 | 3086 | 1379 | 1.59 / 255.81 | 3 | 7 |
3 | 13 | 1600.44 | 18 | 14.90 | 2575 | 691 | 2.28 / 256.50 | 2 | 6 |
4 | 13 | 1151.20 | 18 | 14.95 | 1961 | 528 | 2.81 / 257.03 | 2 | 7 |
5 | 13 | 434.16 | 18 | 15.12 | 949 | 258 | 3.07 / 257.29 | 3 | 5 |
6 | 13 | 47.68 | 18 | 15.20 | 383 | 105 | 3.17 / 257.39 | 3 | 4 |
7 | 8 | 0.08 | 165 | 15.16 | 310 | 775 | 3.95 / 258.17 | 3 | 8 |
Average= | 3.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.40 | 29 | 15.13 | 488 | 214 | 0.21 / 250.62 | 3 | 3 |
2 | 7 | 2010.52 | 30 | 14.91 | 3096 | 1385 | 1.60 / 252.00 | 3 | 4 |
3 | 13 | 1597.32 | 18 | 14.89 | 2575 | 690 | 2.29 / 252.69 | 2 | 10 |
4 | 13 | 1030.60 | 18 | 14.99 | 1813 | 489 | 2.78 / 253.18 | 2 | 7 |
5 | 13 | 458.56 | 18 | 15.11 | 985 | 268 | 3.05 / 253.45 | 3 | 4 |
6 | 8 | 0.04 | 165 | 15.17 | 309 | 773 | 3.82 / 254.22 | 3 | 9 |
Average= | 3.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.24 | 30 | 15.12 | 477 | 216 | 0.22 / 246.73 | 3 | 3 |
2 | 7 | 2002.68 | 30 | 14.91 | 3088 | 1381 | 1.60 / 248.11 | 2 | 3 |
3 | 13 | 1593.08 | 18 | 14.92 | 2569 | 690 | 2.29 / 248.80 | 2 | 4 |
4 | 13 | 1024.68 | 18 | 14.99 | 1806 | 487 | 2.77 / 249.29 | 2 | 4 |
5 | 13 | 340.56 | 18 | 15.16 | 829 | 226 | 3.00 / 249.51 | 3 | 5 |
6 | 13 | 34.96 | 18 | 15.22 | 374 | 102 | 3.10 / 249.62 | 3 | 4 |
7 | 8 | -0.12 | 165 | 15.19 | 313 | 784 | 3.89 / 250.40 | 3 | 9 |
Average= | 3.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.24 | 30 | 15.12 | 470 | 213 | 0.21 / 242.70 | 3 | 3 |
2 | 7 | 2003.00 | 30 | 14.92 | 3074 | 1376 | 1.59 / 244.08 | 3 | 3 |
3 | 13 | 1708.92 | 18 | 14.91 | 2722 | 731 | 2.32 / 244.81 | 2 | 7 |
4 | 13 | 1120.28 | 18 | 14.97 | 1931 | 520 | 2.84 / 245.33 | 2 | 4 |
5 | 13 | 523.24 | 18 | 15.10 | 1089 | 296 | 3.14 / 245.63 | 3 | 4 |
6 | 13 | 42.56 | 18 | 15.21 | 378 | 103 | 3.24 / 245.73 | 3 | 4 |
7 | 8 | 0.08 | 165 | 15.17 | 313 | 783 | 4.02 / 246.51 | 3 | 6 |
Average= | 3.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.28 | 30 | 15.12 | 438 | 199 | 0.20 / 238.80 | 3 | 3 |
2 | 7 | 2004.84 | 30 | 14.91 | 3077 | 1376 | 1.58 / 240.18 | 3 | 4 |
3 | 13 | 1584.84 | 18 | 14.91 | 2554 | 685 | 2.26 / 240.87 | 2 | 7 |
4 | 13 | 1028.48 | 18 | 14.99 | 1800 | 486 | 2.75 / 241.35 | 2 | 4 |
5 | 13 | 449.12 | 18 | 15.11 | 980 | 267 | 3.01 / 241.62 | 3 | 5 |
6 | 13 | 56.20 | 18 | 15.20 | 394 | 108 | 3.12 / 241.73 | 3 | 4 |
7 | 8 | 0.00 | 165 | 15.16 | 306 | 765 | 3.89 / 242.49 | 3 | 9 |
Average= | 3.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.48 | 30 | 15.13 | 473 | 215 | 0.21 / 234.95 | 3 | 3 |
2 | 7 | 2010.24 | 30 | 14.92 | 3077 | 1377 | 1.59 / 236.32 | 3 | 4 |
3 | 13 | 1597.20 | 18 | 14.93 | 2550 | 685 | 2.28 / 237.01 | 2 | 4 |
4 | 13 | 1038.32 | 18 | 14.99 | 1808 | 488 | 2.77 / 237.50 | 2 | 4 |
5 | 13 | 458.40 | 18 | 15.12 | 972 | 265 | 3.03 / 237.76 | 3 | 5 |
6 | 13 | 58.48 | 18 | 15.20 | 389 | 106 | 3.14 / 237.87 | 3 | 4 |
7 | 8 | 0.00 | 165 | 15.18 | 294 | 736 | 3.87 / 238.60 | 3 | 10 |
Average= | 3.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.28 | 30 | 15.12 | 465 | 211 | 0.21 / 231.05 | 3 | 3 |
2 | 7 | 2007.40 | 30 | 14.93 | 3077 | 1378 | 1.59 / 232.43 | 3 | 4 |
3 | 13 | 1602.28 | 18 | 14.92 | 2567 | 689 | 2.28 / 233.12 | 2 | 8 |
4 | 13 | 1040.20 | 18 | 15.00 | 1807 | 488 | 2.77 / 233.60 | 3 | 5 |
5 | 13 | 457.16 | 18 | 15.12 | 986 | 268 | 3.03 / 233.87 | 3 | 4 |
6 | 13 | 62.52 | 18 | 15.21 | 404 | 111 | 3.15 / 233.98 | 3 | 4 |
7 | 8 | 0.12 | 165 | 15.18 | 299 | 749 | 3.89 / 234.73 | 3 | 8 |
Average= | 3.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.00 | 30 | 15.12 | 483 | 219 | 0.22 / 227.21 | 3 | 3 |
2 | 7 | 2007.36 | 30 | 14.92 | 3081 | 1379 | 1.60 / 228.59 | 3 | 7 |
3 | 13 | 1609.32 | 18 | 14.92 | 2573 | 691 | 2.29 / 229.28 | 2 | 7 |
4 | 13 | 1044.84 | 18 | 14.99 | 1817 | 490 | 2.78 / 229.77 | 2 | 4 |
5 | 13 | 348.92 | 18 | 15.16 | 824 | 225 | 3.00 / 229.99 | 3 | 5 |
6 | 13 | 50.04 | 18 | 15.21 | 382 | 105 | 3.11 / 230.10 | 3 | 3 |
7 | 8 | 0.24 | 165 | 15.17 | 296 | 741 | 3.85 / 230.84 | 3 | 10 |
Average= | 3.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.24 | 30 | 15.14 | 470 | 213 | 0.21 / 223.28 | 3 | 3 |
2 | 7 | 2006.28 | 30 | 14.92 | 3086 | 1381 | 1.59 / 224.66 | 3 | 6 |
3 | 13 | 1599.96 | 18 | 14.91 | 2588 | 695 | 2.29 / 225.35 | 2 | 7 |
4 | 13 | 1042.48 | 18 | 14.99 | 1819 | 491 | 2.78 / 225.84 | 2 | 5 |
5 | 13 | 464.32 | 18 | 15.11 | 1002 | 273 | 3.05 / 226.12 | 3 | 6 |
6 | 13 | 44.44 | 18 | 15.20 | 378 | 103 | 3.16 / 226.22 | 3 | 4 |
7 | 8 | -0.08 | 165 | 15.17 | 307 | 768 | 3.92 / 226.99 | 3 | 9 |
Average= | 3.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.80 | 29 | 15.13 | 480 | 211 | 0.21 / 219.38 | 3 | 3 |
2 | 3 | 1020.40 | 1 | 15.27 | 1838 | 28 | 0.24 / 219.41 | 2 | 4 |
3 | 7 | 2009.08 | 30 | 14.91 | 3100 | 1387 | 1.63 / 220.79 | 3 | 4 |
4 | 13 | 1610.32 | 18 | 14.92 | 2592 | 696 | 2.32 / 221.49 | 2 | 8 |
5 | 13 | 1049.36 | 18 | 14.99 | 1829 | 494 | 2.81 / 221.98 | 3 | 6 |
6 | 13 | 371.72 | 18 | 15.15 | 857 | 234 | 3.05 / 222.22 | 3 | 5 |
7 | 13 | 43.08 | 18 | 15.22 | 368 | 101 | 3.15 / 222.32 | 3 | 3 |
8 | 8 | 0.16 | 165 | 15.19 | 298 | 747 | 3.90 / 223.06 | 3 | 9 |
Average= | 3.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.68 | 29 | 15.14 | 468 | 205 | 0.21 / 215.31 | 3 | 3 |
2 | 7 | 2010.04 | 31 | 14.92 | 3095 | 1431 | 1.64 / 216.74 | 3 | 6 |
3 | 13 | 1733.72 | 18 | 14.89 | 2745 | 736 | 2.37 / 217.47 | 2 | 3 |
4 | 13 | 1120.80 | 18 | 14.97 | 1932 | 521 | 2.89 / 217.99 | 2 | 5 |
5 | 13 | 526.40 | 18 | 15.10 | 1100 | 299 | 3.19 / 218.29 | 3 | 4 |
6 | 13 | 43.80 | 18 | 15.21 | 379 | 104 | 3.30 / 218.40 | 3 | 4 |
7 | 8 | 0.16 | 165 | 15.18 | 308 | 771 | 4.07 / 219.17 | 3 | 6 |
Average= | 3.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.76 | 29 | 15.14 | 465 | 204 | 0.20 / 211.37 | 3 | 3 |
2 | 7 | 2009.64 | 30 | 14.92 | 3106 | 1390 | 1.59 / 212.76 | 3 | 5 |
3 | 13 | 1616.32 | 18 | 14.92 | 2609 | 701 | 2.30 / 213.46 | 2 | 5 |
4 | 13 | 1166.60 | 18 | 14.96 | 1997 | 538 | 2.83 / 214.00 | 3 | 4 |
5 | 13 | 430.76 | 18 | 15.14 | 949 | 259 | 3.09 / 214.26 | 3 | 5 |
6 | 13 | 33.12 | 18 | 15.22 | 348 | 95 | 3.19 / 214.35 | 3 | 3 |
7 | 8 | 0.12 | 165 | 15.19 | 298 | 747 | 3.93 / 215.10 | 3 | 14 |
Average= | 3.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.88 | 29 | 15.15 | 467 | 205 | 0.21 / 207.47 | 3 | 3 |
2 | 7 | 2002.88 | 30 | 14.93 | 3081 | 1380 | 1.59 / 208.85 | 3 | 5 |
3 | 13 | 1600.76 | 18 | 14.93 | 2565 | 689 | 2.27 / 209.54 | 2 | 9 |
4 | 13 | 1147.84 | 18 | 14.99 | 1962 | 529 | 2.80 / 210.07 | 2 | 4 |
5 | 13 | 419.56 | 18 | 15.17 | 925 | 253 | 3.06 / 210.33 | 3 | 4 |
6 | 13 | 48.12 | 18 | 15.24 | 377 | 103 | 3.16 / 210.43 | 3 | 4 |
7 | 8 | 0.12 | 165 | 15.21 | 294 | 738 | 3.90 / 211.17 | 3 | 8 |
Average= | 3.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.00 | 29 | 15.16 | 468 | 206 | 0.21 / 203.54 | 3 | 3 |
2 | 7 | 2011.04 | 31 | 14.92 | 3080 | 1425 | 1.63 / 204.97 | 2 | 5 |
3 | 13 | 1600.28 | 18 | 14.93 | 2555 | 687 | 2.32 / 205.66 | 2 | 7 |
4 | 13 | 1037.84 | 18 | 15.01 | 1806 | 488 | 2.80 / 206.14 | 2 | 6 |
5 | 13 | 466.20 | 18 | 15.15 | 996 | 272 | 3.08 / 206.42 | 3 | 6 |
6 | 13 | 33.72 | 18 | 15.25 | 357 | 98 | 3.17 / 206.51 | 3 | 3 |
7 | 8 | -0.04 | 165 | 15.21 | 301 | 755 | 3.93 / 207.27 | 3 | 12 |
Average= | 3.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.32 | 29 | 15.16 | 471 | 207 | 0.21 / 199.72 | 3 | 3 |
2 | 7 | 2008.36 | 30 | 14.91 | 3083 | 1379 | 1.59 / 201.10 | 3 | 5 |
3 | 13 | 1604.20 | 18 | 14.92 | 2570 | 690 | 2.28 / 201.79 | 2 | 6 |
4 | 13 | 1044.20 | 18 | 15.01 | 1815 | 490 | 2.77 / 202.28 | 2 | 4 |
5 | 13 | 360.24 | 18 | 15.17 | 845 | 231 | 3.00 / 202.51 | 3 | 5 |
6 | 13 | 23.52 | 18 | 15.24 | 338 | 93 | 3.09 / 202.60 | 3 | 4 |
7 | 8 | 0.16 | 165 | 15.20 | 294 | 737 | 3.83 / 203.34 | 3 | 6 |
Average= | 3.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.64 | 29 | 15.17 | 465 | 205 | 0.20 / 195.84 | 3 | 3 |
2 | 7 | 2010.64 | 30 | 14.92 | 3082 | 1380 | 1.58 / 197.22 | 3 | 6 |
3 | 13 | 1582.16 | 18 | 14.94 | 2524 | 679 | 2.26 / 197.89 | 2 | 5 |
4 | 13 | 1034.92 | 18 | 15.02 | 1797 | 486 | 2.75 / 198.38 | 2 | 6 |
5 | 13 | 458.72 | 18 | 15.15 | 992 | 271 | 3.02 / 198.65 | 3 | 4 |
6 | 13 | 29.56 | 18 | 15.24 | 359 | 98 | 3.12 / 198.75 | 3 | 4 |
7 | 8 | 0.00 | 165 | 15.20 | 304 | 762 | 3.88 / 199.51 | 3 | 8 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.24 | 29 | 15.19 | 462 | 204 | 0.20 / 192.01 | 3 | 3 |
2 | 7 | 2007.12 | 30 | 14.92 | 3082 | 1380 | 1.58 / 193.39 | 2 | 8 |
3 | 13 | 1606.40 | 18 | 14.93 | 2582 | 694 | 2.28 / 194.08 | 2 | 4 |
4 | 13 | 1038.28 | 18 | 15.02 | 1813 | 490 | 2.77 / 194.57 | 2 | 4 |
5 | 13 | 332.88 | 18 | 15.19 | 805 | 220 | 2.99 / 194.79 | 3 | 5 |
6 | 13 | 35.80 | 18 | 15.25 | 359 | 99 | 3.09 / 194.89 | 3 | 4 |
7 | 8 | 0.08 | 165 | 15.21 | 294 | 738 | 3.82 / 195.63 | 3 | 8 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.56 | 29 | 15.19 | 468 | 206 | 0.21 / 188.19 | 3 | 3 |
2 | 7 | 2005.72 | 30 | 14.94 | 3087 | 1384 | 1.59 / 189.58 | 3 | 4 |
3 | 13 | 1588.64 | 18 | 14.95 | 2563 | 690 | 2.28 / 190.27 | 2 | 9 |
4 | 13 | 1022.12 | 18 | 15.04 | 1786 | 484 | 2.76 / 190.75 | 3 | 4 |
5 | 13 | 332.24 | 18 | 15.21 | 807 | 221 | 2.98 / 190.97 | 3 | 5 |
6 | 13 | 34.76 | 18 | 15.27 | 356 | 98 | 3.08 / 191.07 | 3 | 4 |
7 | 8 | 0.00 | 165 | 15.23 | 294 | 739 | 3.82 / 191.81 | 3 | 9 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.52 | 29 | 15.18 | 470 | 207 | 0.21 / 184.32 | 3 | 3 |
2 | 7 | 2006.56 | 30 | 14.95 | 3089 | 1385 | 1.59 / 185.71 | 3 | 3 |
3 | 13 | 1589.88 | 18 | 14.97 | 2557 | 689 | 2.28 / 186.40 | 2 | 9 |
4 | 13 | 1018.36 | 18 | 15.06 | 1793 | 486 | 2.77 / 186.89 | 2 | 7 |
5 | 13 | 442.56 | 18 | 15.20 | 968 | 265 | 3.03 / 187.15 | 3 | 6 |
6 | 13 | 26.96 | 18 | 15.27 | 338 | 93 | 3.13 / 187.24 | 3 | 3 |
7 | 8 | 0.04 | 165 | 15.24 | 296 | 744 | 3.87 / 187.99 | 3 | 10 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.52 | 29 | 15.20 | 470 | 207 | 0.21 / 180.43 | 3 | 3 |
2 | 7 | 2003.56 | 30 | 14.95 | 3078 | 1380 | 1.59 / 181.81 | 3 | 5 |
3 | 13 | 1606.20 | 18 | 14.95 | 2588 | 696 | 2.28 / 182.50 | 2 | 6 |
4 | 13 | 1032.68 | 18 | 15.05 | 1809 | 490 | 2.77 / 182.99 | 3 | 7 |
5 | 13 | 453.88 | 18 | 15.19 | 982 | 268 | 3.04 / 183.26 | 3 | 7 |
6 | 13 | 23.96 | 18 | 15.28 | 345 | 95 | 3.14 / 183.36 | 3 | 3 |
7 | 8 | 0.08 | 165 | 15.24 | 303 | 762 | 3.90 / 184.12 | 3 | 10 |
Average= | 3.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.00 | 29 | 15.21 | 469 | 207 | 0.21 / 176.61 | 3 | 3 |
2 | 7 | 2005.08 | 30 | 14.95 | 3071 | 1377 | 1.58 / 177.99 | 3 | 7 |
3 | 13 | 1593.52 | 18 | 14.96 | 2551 | 687 | 2.27 / 178.68 | 2 | 4 |
4 | 13 | 1029.24 | 18 | 15.06 | 1805 | 489 | 2.76 / 179.17 | 3 | 4 |
5 | 13 | 331.76 | 18 | 15.22 | 805 | 221 | 2.98 / 179.39 | 3 | 5 |
6 | 13 | 16.40 | 18 | 15.29 | 328 | 90 | 3.07 / 179.48 | 3 | 4 |
7 | 8 | 0.04 | 165 | 15.25 | 294 | 740 | 3.81 / 180.22 | 3 | 8 |
Average= | 3.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.44 | 29 | 15.21 | 458 | 202 | 0.20 / 172.67 | 3 | 3 |
2 | 7 | 2002.60 | 30 | 14.99 | 3088 | 1389 | 1.59 / 174.06 | 3 | 5 |
3 | 13 | 1731.72 | 18 | 14.95 | 2744 | 738 | 2.33 / 174.80 | 2 | 4 |
4 | 13 | 1141.16 | 18 | 15.04 | 1956 | 530 | 2.86 / 175.33 | 3 | 8 |
5 | 13 | 556.48 | 18 | 15.18 | 1138 | 311 | 3.17 / 175.64 | 3 | 5 |
6 | 8 | 0.04 | 165 | 15.27 | 306 | 771 | 3.94 / 176.41 | 3 | 7 |
Average= | 3.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.40 | 29 | 15.21 | 477 | 210 | 0.21 / 168.94 | 3 | 3 |
2 | 7 | 2003.80 | 30 | 14.97 | 3083 | 1385 | 1.59 / 170.32 | 3 | 6 |
3 | 13 | 1495.04 | 18 | 15.00 | 2421 | 654 | 2.25 / 170.98 | 2 | 8 |
4 | 13 | 1069.72 | 18 | 15.06 | 1858 | 504 | 2.75 / 171.48 | 2 | 7 |
5 | 13 | 359.24 | 18 | 15.24 | 842 | 231 | 2.98 / 171.71 | 3 | 5 |
6 | 8 | 0.00 | 165 | 15.28 | 300 | 756 | 3.74 / 172.47 | 3 | 8 |
Average= | 3.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.64 | 29 | 15.22 | 463 | 204 | 0.20 / 164.97 | 3 | 3 |
2 | 7 | 2010.64 | 30 | 14.96 | 3101 | 1392 | 1.60 / 166.36 | 3 | 7 |
3 | 13 | 1599.68 | 18 | 14.97 | 2572 | 693 | 2.29 / 167.06 | 2 | 8 |
4 | 13 | 1158.80 | 18 | 15.03 | 1983 | 536 | 2.83 / 167.59 | 2 | 5 |
5 | 13 | 542.24 | 18 | 15.18 | 1098 | 300 | 3.13 / 167.89 | 3 | 4 |
6 | 13 | 22.56 | 18 | 15.30 | 336 | 93 | 3.22 / 167.98 | 3 | 4 |
7 | 8 | 0.04 | 165 | 15.26 | 295 | 743 | 3.96 / 168.73 | 3 | 7 |
Average= | 3.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.72 | 29 | 15.23 | 447 | 197 | 0.20 / 161.23 | 3 | 3 |
2 | 7 | 2007.08 | 30 | 14.96 | 3063 | 1375 | 1.57 / 162.61 | 3 | 8 |
3 | 13 | 1731.84 | 18 | 14.96 | 2728 | 735 | 2.31 / 163.34 | 2 | 6 |
4 | 13 | 989.40 | 18 | 15.07 | 1720 | 467 | 2.77 / 163.81 | 2 | 5 |
5 | 13 | 417.96 | 18 | 15.23 | 903 | 248 | 3.02 / 164.06 | 3 | 6 |
6 | 8 | 0.04 | 165 | 15.28 | 281 | 708 | 3.73 / 164.77 | 3 | 10 |
Average= | 3.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.68 | 29 | 15.25 | 448 | 198 | 0.20 / 157.38 | 3 | 3 |
2 | 3 | 1018.08 | 1 | 15.31 | 1832 | 28 | 0.23 / 157.40 | 2 | 3 |
3 | 7 | 2003.76 | 31 | 14.97 | 3076 | 1427 | 1.65 / 158.83 | 3 | 5 |
4 | 13 | 1585.32 | 18 | 14.98 | 2531 | 682 | 2.34 / 159.51 | 2 | 9 |
5 | 13 | 1024.40 | 18 | 15.09 | 1768 | 480 | 2.82 / 159.99 | 3 | 7 |
6 | 13 | 445.12 | 18 | 15.22 | 942 | 258 | 3.07 / 160.25 | 3 | 6 |
7 | 13 | 27.20 | 18 | 15.29 | 323 | 89 | 3.16 / 160.34 | 3 | 3 |
8 | 8 | 0.00 | 165 | 15.28 | 276 | 696 | 3.86 / 161.04 | 3 | 8 |
Average= | 3.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.24 | 29 | 15.24 | 438 | 194 | 0.19 / 153.66 | 3 | 3 |
2 | 7 | 2009.08 | 31 | 14.98 | 3097 | 1438 | 1.63 / 155.09 | 3 | 11 |
3 | 13 | 1586.56 | 18 | 15.00 | 2542 | 686 | 2.32 / 155.78 | 2 | 12 |
4 | 13 | 1031.24 | 18 | 15.09 | 1784 | 485 | 2.80 / 156.27 | 2 | 6 |
5 | 13 | 337.28 | 18 | 15.26 | 787 | 216 | 3.02 / 156.48 | 3 | 4 |
6 | 8 | 0.20 | 165 | 15.29 | 276 | 696 | 3.72 / 157.18 | 3 | 7 |
Average= | 3.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.08 | 29 | 15.23 | 449 | 198 | 0.20 / 149.98 | 3 | 3 |
2 | 7 | 2007.84 | 30 | 14.98 | 3091 | 1389 | 1.59 / 151.37 | 3 | 5 |
3 | 13 | 1600.72 | 18 | 15.00 | 2555 | 690 | 2.28 / 152.06 | 2 | 10 |
4 | 13 | 1029.32 | 18 | 15.09 | 1783 | 484 | 2.76 / 152.54 | 2 | 5 |
5 | 13 | 330.60 | 18 | 15.27 | 780 | 214 | 2.98 / 152.76 | 3 | 4 |
6 | 8 | -0.04 | 165 | 15.29 | 279 | 704 | 3.68 / 153.46 | 3 | 8 |
Average= | 3.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.24 | 29 | 15.23 | 449 | 198 | 0.20 / 146.16 | 3 | 3 |
2 | 7 | 2004.16 | 31 | 14.97 | 3067 | 1423 | 1.62 / 147.58 | 3 | 5 |
3 | 13 | 1472.00 | 18 | 15.01 | 2386 | 645 | 2.27 / 148.23 | 2 | 12 |
4 | 13 | 1071.24 | 18 | 15.07 | 1836 | 498 | 2.76 / 148.73 | 2 | 5 |
5 | 13 | 477.20 | 18 | 15.21 | 994 | 272 | 3.04 / 149.00 | 3 | 5 |
6 | 13 | 16.36 | 18 | 15.30 | 309 | 85 | 3.12 / 149.08 | 3 | 4 |
7 | 8 | 0.08 | 165 | 15.28 | 277 | 698 | 3.82 / 149.78 | 3 | 8 |
Average= | 3.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.96 | 29 | 15.25 | 431 | 191 | 0.19 / 142.41 | 3 | 3 |
2 | 7 | 2004.40 | 30 | 14.98 | 3079 | 1384 | 1.57 / 143.80 | 3 | 5 |
3 | 13 | 1588.40 | 18 | 15.00 | 2539 | 686 | 2.26 / 144.48 | 3 | 6 |
4 | 13 | 1030.08 | 18 | 15.09 | 1783 | 484 | 2.74 / 144.97 | 2 | 5 |
5 | 13 | 324.80 | 18 | 15.25 | 771 | 212 | 2.96 / 145.18 | 3 | 4 |
6 | 13 | 17.76 | 18 | 15.30 | 312 | 86 | 3.04 / 145.26 | 3 | 4 |
7 | 8 | 0.04 | 165 | 15.28 | 277 | 698 | 3.74 / 145.96 | 3 | 10 |
Average= | 3.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.20 | 29 | 15.26 | 436 | 193 | 0.19 / 138.67 | 3 | 3 |
2 | 7 | 2005.88 | 31 | 14.98 | 3085 | 1433 | 1.63 / 140.10 | 3 | 3 |
3 | 13 | 1596.44 | 18 | 14.99 | 2545 | 687 | 2.31 / 140.79 | 2 | 4 |
4 | 13 | 1017.32 | 18 | 15.10 | 1764 | 479 | 2.79 / 141.27 | 3 | 4 |
5 | 13 | 431.12 | 18 | 15.24 | 927 | 254 | 3.05 / 141.52 | 3 | 4 |
6 | 8 | 0.24 | 165 | 15.30 | 278 | 702 | 3.75 / 142.22 | 3 | 13 |
Average= | 3.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.48 | 29 | 15.25 | 441 | 195 | 0.20 / 134.74 | 3 | 3 |
2 | 7 | 2003.28 | 30 | 15.00 | 3080 | 1386 | 1.58 / 136.13 | 3 | 3 |
3 | 13 | 1582.88 | 18 | 15.02 | 2528 | 683 | 2.26 / 136.81 | 2 | 3 |
4 | 13 | 1003.12 | 18 | 15.12 | 1746 | 475 | 2.74 / 137.29 | 3 | 3 |
5 | 13 | 431.40 | 18 | 15.24 | 927 | 254 | 2.99 / 137.54 | 3 | 4 |
6 | 13 | 53.44 | 18 | 15.33 | 368 | 102 | 3.10 / 137.64 | 3 | 3 |
7 | 8 | 0.12 | 165 | 15.30 | 279 | 704 | 3.80 / 138.35 | 3 | 8 |
8 | 14 | 0.12 | 30 | 15.28 | 277 | 127 | 3.93 / 138.47 | 3 | 11 |
Average= | 3.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.36 | 29 | 15.25 | 429 | 190 | 0.19 / 131.09 | 3 | 3 |
2 | 7 | 2004.32 | 30 | 14.98 | 3084 | 1386 | 1.58 / 132.48 | 3 | 3 |
3 | 13 | 1596.16 | 18 | 15.00 | 2549 | 688 | 2.26 / 133.16 | 2 | 3 |
4 | 13 | 1023.12 | 18 | 15.10 | 1769 | 481 | 2.74 / 133.64 | 2 | 3 |
5 | 13 | 319.84 | 18 | 15.26 | 762 | 209 | 2.95 / 133.85 | 3 | 3 |
6 | 8 | 0.04 | 165 | 15.30 | 275 | 694 | 3.65 / 134.55 | 3 | 10 |
Average= | 3.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.16 | 29 | 15.23 | 436 | 193 | 0.19 / 127.40 | 3 | 3 |
2 | 7 | 2004.72 | 30 | 14.98 | 3082 | 1385 | 1.58 / 128.79 | 3 | 3 |
3 | 13 | 1581.16 | 18 | 15.01 | 2527 | 683 | 2.26 / 129.47 | 2 | 3 |
4 | 13 | 1012.16 | 18 | 15.11 | 1755 | 477 | 2.74 / 129.95 | 2 | 4 |
5 | 13 | 435.68 | 18 | 15.24 | 929 | 255 | 2.99 / 130.20 | 3 | 4 |
6 | 8 | 0.24 | 165 | 15.30 | 276 | 697 | 3.69 / 130.90 | 3 | 10 |
Average= | 3.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.64 | 29 | 15.25 | 440 | 195 | 0.19 / 123.68 | 3 | 3 |
2 | 7 | 2003.84 | 30 | 14.98 | 3088 | 1388 | 1.58 / 125.07 | 3 | 3 |
3 | 13 | 1476.64 | 18 | 15.03 | 2384 | 645 | 2.23 / 125.72 | 2 | 3 |
4 | 13 | 1046.28 | 18 | 15.09 | 1802 | 489 | 2.72 / 126.21 | 2 | 4 |
5 | 13 | 315.96 | 18 | 15.27 | 759 | 209 | 2.93 / 126.41 | 3 | 4 |
6 | 13 | 28.88 | 18 | 15.33 | 331 | 91 | 3.02 / 126.51 | 3 | 4 |
7 | 8 | -0.04 | 165 | 15.30 | 279 | 704 | 3.72 / 127.21 | 3 | 7 |
Average= | 3.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.00 | 29 | 15.25 | 446 | 197 | 0.20 / 119.87 | 3 | 3 |
2 | 7 | 2011.44 | 30 | 14.99 | 3077 | 1384 | 1.58 / 121.25 | 3 | 3 |
3 | 13 | 1588.36 | 18 | 15.02 | 2539 | 686 | 2.27 / 121.94 | 2 | 3 |
4 | 13 | 1142.36 | 18 | 15.08 | 1933 | 525 | 2.79 / 122.46 | 2 | 4 |
5 | 13 | 402.28 | 18 | 15.26 | 887 | 244 | 3.04 / 122.70 | 3 | 4 |
6 | 13 | 21.88 | 18 | 15.33 | 321 | 89 | 3.12 / 122.79 | 3 | 4 |
7 | 8 | 0.16 | 165 | 15.30 | 276 | 697 | 3.82 / 123.49 | 3 | 8 |
Average= | 3.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.16 | 29 | 15.24 | 439 | 194 | 0.19 / 116.02 | 3 | 3 |
2 | 7 | 2003.84 | 31 | 14.97 | 3061 | 1421 | 1.61 / 117.44 | 3 | 3 |
3 | 13 | 1584.16 | 18 | 15.00 | 2534 | 684 | 2.30 / 118.12 | 2 | 3 |
4 | 13 | 1134.24 | 18 | 15.08 | 1922 | 522 | 2.82 / 118.64 | 2 | 4 |
5 | 13 | 392.96 | 18 | 15.25 | 867 | 238 | 3.06 / 118.88 | 3 | 4 |
6 | 13 | 53.00 | 18 | 15.31 | 362 | 100 | 3.16 / 118.98 | 3 | 4 |
7 | 8 | 0.04 | 165 | 15.28 | 273 | 688 | 3.85 / 119.67 | 3 | 8 |
Average= | 3.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.84 | 29 | 15.24 | 423 | 187 | 0.19 / 112.08 | 3 | 3 |
2 | 7 | 2003.80 | 30 | 14.99 | 3062 | 1377 | 1.56 / 113.45 | 3 | 3 |
3 | 13 | 1591.88 | 18 | 15.02 | 2541 | 687 | 2.25 / 114.14 | 2 | 3 |
4 | 13 | 1147.72 | 18 | 15.08 | 1940 | 527 | 2.78 / 114.67 | 2 | 3 |
5 | 13 | 386.88 | 18 | 15.27 | 857 | 236 | 3.01 / 114.90 | 3 | 4 |
6 | 13 | 47.16 | 18 | 15.34 | 354 | 98 | 3.11 / 115.00 | 3 | 4 |
7 | 8 | 0.20 | 165 | 15.30 | 275 | 694 | 3.81 / 115.70 | 3 | 12 |
8 | 14 | 0.20 | 30 | 15.28 | 276 | 127 | 3.93 / 115.82 | 3 | 9 |
Average= | 3.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.32 | 28 | 15.24 | 442 | 189 | 0.19 / 108.36 | 3 | 3 |
2 | 7 | 2003.60 | 30 | 15.00 | 3075 | 1384 | 1.57 / 109.74 | 2 | 3 |
3 | 13 | 1583.20 | 18 | 15.02 | 2520 | 681 | 2.25 / 110.42 | 2 | 3 |
4 | 13 | 1015.80 | 18 | 15.12 | 1763 | 480 | 2.73 / 110.90 | 2 | 4 |
5 | 13 | 315.68 | 18 | 15.28 | 754 | 207 | 2.94 / 111.11 | 3 | 3 |
6 | 13 | 46.16 | 18 | 15.33 | 348 | 96 | 3.04 / 111.21 | 3 | 4 |
7 | 8 | 0.12 | 165 | 15.30 | 271 | 684 | 3.72 / 111.89 | 3 | 11 |
Average= | 3.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.44 | 28 | 15.26 | 447 | 191 | 0.19 / 104.57 | 3 | 3 |
2 | 7 | 2005.00 | 30 | 15.00 | 3079 | 1386 | 1.58 / 105.96 | 3 | 3 |
3 | 13 | 1591.08 | 18 | 15.02 | 2541 | 687 | 2.26 / 106.64 | 2 | 3 |
4 | 13 | 1018.28 | 18 | 15.12 | 1765 | 480 | 2.74 / 107.12 | 2 | 3 |
5 | 13 | 436.56 | 18 | 15.25 | 932 | 256 | 3.00 / 107.38 | 3 | 4 |
6 | 13 | 54.56 | 18 | 15.32 | 367 | 101 | 3.10 / 107.48 | 3 | 4 |
7 | 8 | 0.16 | 165 | 15.30 | 273 | 689 | 3.79 / 108.17 | 3 | 8 |
Average= | 3.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.32 | 28 | 15.26 | 436 | 186 | 0.19 / 100.79 | 3 | 3 |
2 | 7 | 2003.68 | 30 | 15.00 | 3069 | 1381 | 1.57 / 102.17 | 3 | 3 |
3 | 13 | 1578.80 | 18 | 15.03 | 2525 | 683 | 2.25 / 102.85 | 2 | 3 |
4 | 13 | 1008.36 | 18 | 15.13 | 1746 | 476 | 2.73 / 103.33 | 2 | 3 |
5 | 13 | 420.60 | 18 | 15.27 | 909 | 250 | 2.98 / 103.58 | 2 | 4 |
6 | 13 | 50.84 | 18 | 15.34 | 365 | 101 | 3.08 / 103.68 | 3 | 4 |
7 | 8 | 0.04 | 165 | 15.30 | 277 | 699 | 3.78 / 104.38 | 3 | 10 |
Average= | 3.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.08 | 28 | 15.26 | 436 | 186 | 0.19 / 97.07 | 3 | 3 |
2 | 7 | 2004.12 | 30 | 15.01 | 3069 | 1382 | 1.57 / 98.45 | 3 | 3 |
3 | 13 | 1470.12 | 18 | 15.06 | 2388 | 647 | 2.22 / 99.10 | 2 | 3 |
4 | 13 | 1056.52 | 18 | 15.12 | 1815 | 494 | 2.71 / 99.59 | 2 | 4 |
5 | 13 | 329.64 | 18 | 15.29 | 779 | 214 | 2.92 / 99.81 | 3 | 4 |
6 | 13 | 38.96 | 18 | 15.34 | 345 | 95 | 3.02 / 99.90 | 3 | 4 |
7 | 8 | 0.00 | 165 | 15.31 | 278 | 702 | 3.72 / 100.60 | 3 | 9 |
Average= | 3.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.68 | 28 | 15.26 | 450 | 192 | 0.19 / 93.29 | 3 | 3 |
2 | 7 | 2003.48 | 30 | 14.99 | 3073 | 1382 | 1.57 / 94.67 | 3 | 3 |
3 | 13 | 1583.96 | 18 | 15.02 | 2533 | 685 | 2.26 / 95.36 | 2 | 3 |
4 | 13 | 1001.36 | 18 | 15.12 | 1744 | 475 | 2.73 / 95.83 | 2 | 4 |
5 | 13 | 430.92 | 18 | 15.25 | 926 | 254 | 2.99 / 96.09 | 3 | 4 |
6 | 13 | 28.76 | 18 | 15.34 | 332 | 92 | 3.08 / 96.18 | 3 | 4 |
7 | 8 | 0.16 | 165 | 15.30 | 278 | 702 | 3.78 / 96.88 | 3 | 9 |
Average= | 3.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.36 | 28 | 15.27 | 443 | 189 | 0.19 / 89.46 | 3 | 3 |
2 | 7 | 2005.00 | 31 | 15.01 | 3081 | 1434 | 1.62 / 90.89 | 3 | 3 |
3 | 13 | 1580.16 | 18 | 15.04 | 2528 | 684 | 2.31 / 91.57 | 2 | 3 |
4 | 13 | 1011.80 | 18 | 15.12 | 1756 | 478 | 2.79 / 92.05 | 2 | 4 |
5 | 13 | 430.08 | 18 | 15.26 | 927 | 255 | 3.04 / 92.31 | 3 | 4 |
6 | 13 | 24.56 | 18 | 15.34 | 324 | 89 | 3.13 / 92.40 | 3 | 4 |
7 | 8 | 0.08 | 165 | 15.31 | 279 | 705 | 3.83 / 93.10 | 3 | 7 |
Average= | 3.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.12 | 28 | 15.26 | 442 | 189 | 0.19 / 85.60 | 3 | 3 |
2 | 7 | 2005.60 | 31 | 15.00 | 3082 | 1433 | 1.62 / 87.04 | 2 | 3 |
3 | 13 | 1581.12 | 18 | 15.03 | 2527 | 684 | 2.31 / 87.72 | 2 | 3 |
4 | 13 | 1118.08 | 18 | 15.10 | 1899 | 516 | 2.82 / 88.24 | 2 | 3 |
5 | 13 | 372.96 | 18 | 15.29 | 847 | 233 | 3.05 / 88.47 | 3 | 4 |
6 | 13 | 24.08 | 18 | 15.35 | 327 | 90 | 3.15 / 88.56 | 3 | 4 |
7 | 8 | 0.04 | 165 | 15.31 | 280 | 707 | 3.85 / 89.27 | 3 | 10 |
Average= | 3.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.20 | 28 | 15.26 | 421 | 180 | 0.18 / 81.81 | 3 | 3 |
2 | 7 | 2009.40 | 30 | 15.01 | 3092 | 1392 | 1.57 / 83.20 | 3 | 3 |
3 | 13 | 1603.08 | 18 | 15.03 | 2552 | 690 | 2.26 / 83.89 | 2 | 3 |
4 | 13 | 1023.08 | 18 | 15.13 | 1766 | 481 | 2.74 / 84.37 | 2 | 3 |
5 | 13 | 436.72 | 18 | 15.26 | 930 | 255 | 3.00 / 84.63 | 3 | 4 |
6 | 13 | 27.96 | 18 | 15.35 | 330 | 91 | 3.09 / 84.72 | 3 | 3 |
7 | 8 | 0.04 | 165 | 15.32 | 275 | 695 | 3.79 / 85.41 | 3 | 9 |
Average= | 3.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.40 | 28 | 15.27 | 435 | 186 | 0.19 / 78.09 | 3 | 3 |
2 | 7 | 2009.60 | 31 | 15.00 | 3085 | 1435 | 1.62 / 79.52 | 3 | 3 |
3 | 13 | 1456.44 | 18 | 15.08 | 2353 | 639 | 2.26 / 80.16 | 2 | 3 |
4 | 13 | 923.20 | 18 | 15.16 | 1634 | 446 | 2.71 / 80.61 | 2 | 4 |
5 | 13 | 362.48 | 18 | 15.28 | 827 | 227 | 2.93 / 80.84 | 3 | 4 |
6 | 13 | 37.40 | 18 | 15.36 | 342 | 95 | 3.03 / 80.93 | 3 | 4 |
7 | 8 | -0.04 | 165 | 15.32 | 276 | 698 | 3.72 / 81.63 | 3 | 7 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.64 | 28 | 15.28 | 436 | 187 | 0.19 / 74.29 | 3 | 3 |
2 | 7 | 2012.24 | 31 | 15.01 | 3091 | 1438 | 1.62 / 75.73 | 3 | 3 |
3 | 13 | 1589.32 | 18 | 15.05 | 2536 | 687 | 2.31 / 76.41 | 2 | 3 |
4 | 13 | 1027.64 | 18 | 15.15 | 1780 | 485 | 2.80 / 76.90 | 2 | 4 |
5 | 13 | 314.92 | 18 | 15.31 | 759 | 209 | 3.01 / 77.11 | 3 | 4 |
6 | 13 | 31.72 | 18 | 15.36 | 333 | 92 | 3.10 / 77.20 | 3 | 4 |
7 | 8 | 0.08 | 165 | 15.33 | 278 | 703 | 3.80 / 77.90 | 3 | 5 |
Average= | 3.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.64 | 28 | 15.29 | 438 | 188 | 0.19 / 70.50 | 3 | 3 |
2 | 7 | 2009.52 | 30 | 15.03 | 3083 | 1390 | 1.58 / 71.89 | 3 | 3 |
3 | 13 | 1597.00 | 18 | 15.03 | 2547 | 689 | 2.27 / 72.58 | 2 | 3 |
4 | 13 | 1020.24 | 18 | 15.14 | 1767 | 482 | 2.75 / 73.06 | 2 | 4 |
5 | 13 | 445.56 | 18 | 15.27 | 948 | 261 | 3.01 / 73.32 | 3 | 4 |
6 | 13 | 10.56 | 18 | 15.36 | 301 | 83 | 3.09 / 73.40 | 3 | 4 |
7 | 8 | 0.20 | 165 | 15.32 | 277 | 700 | 3.79 / 74.10 | 3 | 8 |
Average= | 3.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.16 | 28 | 15.29 | 442 | 189 | 0.19 / 66.66 | 3 | 3 |
2 | 7 | 2009.44 | 30 | 15.03 | 3095 | 1396 | 1.58 / 68.06 | 3 | 3 |
3 | 13 | 1590.04 | 18 | 15.06 | 2545 | 690 | 2.27 / 68.75 | 2 | 3 |
4 | 13 | 1148.96 | 18 | 15.12 | 1942 | 529 | 2.80 / 69.28 | 2 | 3 |
5 | 13 | 392.88 | 18 | 15.30 | 871 | 240 | 3.04 / 69.52 | 3 | 4 |
6 | 13 | 23.12 | 18 | 15.37 | 321 | 89 | 3.13 / 69.61 | 3 | 4 |
7 | 8 | 0.08 | 165 | 15.34 | 278 | 704 | 3.84 / 70.31 | 3 | 9 |
Average= | 3.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.40 | 28 | 15.28 | 440 | 188 | 0.19 / 62.80 | 3 | 3 |
2 | 7 | 2003.52 | 31 | 15.04 | 3083 | 1437 | 1.63 / 64.24 | 3 | 3 |
3 | 13 | 1587.96 | 18 | 15.06 | 2540 | 689 | 2.31 / 64.92 | 2 | 3 |
4 | 13 | 1124.44 | 18 | 15.13 | 1905 | 519 | 2.83 / 65.44 | 2 | 3 |
5 | 13 | 379.16 | 18 | 15.31 | 850 | 234 | 3.07 / 65.68 | 3 | 4 |
6 | 13 | 39.80 | 18 | 15.37 | 345 | 95 | 3.16 / 65.77 | 3 | 4 |
7 | 8 | 0.04 | 165 | 15.34 | 277 | 701 | 3.86 / 66.47 | 3 | 10 |
Average= | 3.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.60 | 28 | 15.30 | 442 | 189 | 0.19 / 59.05 | 3 | 3 |
2 | 7 | 2003.36 | 30 | 15.04 | 3087 | 1393 | 1.58 / 60.45 | 3 | 3 |
3 | 13 | 1596.04 | 18 | 15.07 | 2552 | 692 | 2.27 / 61.14 | 2 | 3 |
4 | 13 | 1011.80 | 18 | 15.17 | 1761 | 481 | 2.76 / 61.62 | 2 | 4 |
5 | 13 | 294.88 | 18 | 15.34 | 730 | 202 | 2.96 / 61.82 | 3 | 3 |
6 | 13 | 30.28 | 18 | 15.38 | 330 | 91 | 3.05 / 61.91 | 3 | 4 |
7 | 8 | 0.00 | 165 | 15.35 | 276 | 699 | 3.75 / 62.61 | 3 | 10 |
Average= | 3.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.56 | 28 | 15.31 | 439 | 188 | 0.19 / 55.25 | 3 | 3 |
2 | 7 | 2003.76 | 30 | 15.04 | 3083 | 1391 | 1.58 / 56.65 | 3 | 3 |
3 | 13 | 1590.72 | 18 | 15.08 | 2548 | 692 | 2.27 / 57.34 | 2 | 3 |
4 | 13 | 1015.20 | 18 | 15.17 | 1766 | 482 | 2.75 / 57.82 | 2 | 3 |
5 | 13 | 426.52 | 18 | 15.30 | 917 | 253 | 3.01 / 58.07 | 3 | 4 |
6 | 13 | 22.00 | 18 | 15.39 | 322 | 89 | 3.09 / 58.16 | 3 | 4 |
7 | 8 | 0.00 | 165 | 15.35 | 277 | 702 | 3.80 / 58.86 | 3 | 6 |
Average= | 3.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.48 | 28 | 15.30 | 436 | 187 | 0.19 / 51.55 | 3 | 3 |
2 | 7 | 2005.88 | 30 | 15.05 | 3080 | 1391 | 1.58 / 52.94 | 3 | 3 |
3 | 13 | 1465.60 | 18 | 15.10 | 2377 | 646 | 2.22 / 53.59 | 2 | 3 |
4 | 13 | 1038.84 | 18 | 15.17 | 1797 | 491 | 2.71 / 54.08 | 2 | 3 |
5 | 13 | 309.80 | 18 | 15.34 | 747 | 206 | 2.92 / 54.29 | 3 | 4 |
6 | 13 | 13.88 | 18 | 15.39 | 305 | 84 | 3.00 / 54.37 | 3 | 4 |
7 | 8 | 0.12 | 165 | 15.35 | 275 | 697 | 3.70 / 55.07 | 3 | 8 |
Average= | 3.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.80 | 28 | 15.31 | 449 | 192 | 0.19 / 47.90 | 3 | 3 |
2 | 7 | 2002.96 | 30 | 15.04 | 3082 | 1391 | 1.58 / 49.29 | 3 | 3 |
3 | 13 | 1575.08 | 18 | 15.08 | 2527 | 686 | 2.27 / 49.98 | 2 | 3 |
4 | 13 | 1006.00 | 18 | 15.17 | 1755 | 479 | 2.75 / 50.46 | 2 | 4 |
5 | 13 | 293.36 | 18 | 15.34 | 728 | 201 | 2.95 / 50.66 | 3 | 4 |
6 | 8 | 0.00 | 165 | 15.35 | 279 | 707 | 3.66 / 51.37 | 3 | 9 |
Average= | 3.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.16 | 28 | 15.32 | 450 | 193 | 0.19 / 44.29 | 3 | 3 |
2 | 7 | 2003.44 | 30 | 15.05 | 3085 | 1393 | 1.59 / 45.68 | 3 | 3 |
3 | 13 | 1461.64 | 18 | 15.10 | 2366 | 643 | 2.23 / 46.33 | 2 | 3 |
4 | 13 | 1024.04 | 18 | 15.17 | 1769 | 483 | 2.71 / 46.81 | 2 | 3 |
5 | 13 | 289.88 | 18 | 15.34 | 718 | 198 | 2.91 / 47.01 | 3 | 4 |
6 | 8 | 0.24 | 165 | 15.36 | 277 | 702 | 3.61 / 47.71 | 3 | 10 |
Average= | 3.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.08 | 28 | 15.31 | 441 | 189 | 0.19 / 40.63 | 3 | 3 |
2 | 7 | 2003.44 | 30 | 15.05 | 3077 | 1389 | 1.58 / 42.02 | 3 | 3 |
3 | 13 | 1593.64 | 18 | 15.09 | 2545 | 691 | 2.27 / 42.71 | 2 | 3 |
4 | 13 | 1001.20 | 18 | 15.18 | 1745 | 477 | 2.75 / 43.19 | 2 | 3 |
5 | 13 | 289.68 | 18 | 15.34 | 720 | 199 | 2.95 / 43.39 | 3 | 4 |
6 | 8 | 0.12 | 165 | 15.37 | 279 | 708 | 3.65 / 44.10 | 3 | 9 |
Average= | 3.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.12 | 28 | 15.34 | 450 | 193 | 0.19 / 36.98 | 3 | 3 |
2 | 7 | 1991.16 | 30 | 15.07 | 3072 | 1389 | 1.58 / 38.36 | 3 | 3 |
3 | 13 | 1578.52 | 18 | 15.09 | 2529 | 687 | 2.27 / 39.05 | 2 | 3 |
4 | 13 | 1014.04 | 18 | 15.18 | 1764 | 482 | 2.75 / 39.53 | 2 | 3 |
5 | 13 | 293.28 | 18 | 15.35 | 727 | 201 | 2.95 / 39.73 | 3 | 4 |
6 | 8 | 0.12 | 165 | 15.37 | 280 | 710 | 3.66 / 40.44 | 3 | 8 |
Average= | 3.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.08 | 28 | 15.34 | 451 | 194 | 0.19 / 33.23 | 3 | 3 |
2 | 7 | 1979.80 | 30 | 15.08 | 3062 | 1385 | 1.58 / 34.62 | 3 | 3 |
3 | 13 | 1691.40 | 18 | 15.08 | 2695 | 732 | 2.31 / 35.35 | 2 | 3 |
4 | 13 | 1068.44 | 18 | 15.18 | 1836 | 502 | 2.81 / 35.85 | 3 | 3 |
5 | 13 | 333.80 | 18 | 15.35 | 786 | 217 | 3.03 / 36.07 | 3 | 4 |
6 | 8 | 0.12 | 165 | 15.38 | 281 | 713 | 3.74 / 36.78 | 3 | 8 |
Average= | 3.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.08 | 28 | 15.32 | 429 | 184 | 0.18 / 29.57 | 3 | 3 |
2 | 7 | 2004.16 | 30 | 15.08 | 3083 | 1395 | 1.58 / 30.97 | 3 | 3 |
3 | 13 | 1580.96 | 18 | 15.09 | 2532 | 688 | 2.27 / 31.66 | 2 | 3 |
4 | 13 | 999.00 | 18 | 15.19 | 1737 | 475 | 2.74 / 32.13 | 2 | 4 |
5 | 13 | 289.80 | 18 | 15.36 | 719 | 199 | 2.94 / 32.33 | 3 | 4 |
6 | 8 | 0.12 | 165 | 15.38 | 280 | 711 | 3.65 / 33.04 | 3 | 8 |
Average= | 3.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.64 | 28 | 15.31 | 445 | 191 | 0.19 / 25.91 | 3 | 3 |
2 | 12 | 1143.20 | 2 | 15.44 | 2006 | 62 | 0.25 / 25.97 | 2 | 3 |
3 | 7 | 1976.76 | 31 | 15.06 | 3049 | 1423 | 1.68 / 27.39 | 3 | 3 |
4 | 13 | 1531.04 | 18 | 15.10 | 2463 | 669 | 2.35 / 28.06 | 2 | 3 |
5 | 13 | 941.00 | 18 | 15.20 | 1659 | 454 | 2.80 / 28.52 | 2 | 4 |
6 | 13 | 203.64 | 18 | 15.37 | 593 | 164 | 2.96 / 28.68 | 3 | 4 |
7 | 8 | 0.16 | 165 | 15.38 | 279 | 708 | 3.67 / 29.39 | 3 | 9 |
Average= | 3.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.72 | 28 | 15.32 | 440 | 189 | 0.19 / 22.28 | 3 | 3 |
2 | 12 | 1162.32 | 2 | 15.43 | 2029 | 63 | 0.25 / 22.35 | 3 | 3 |
3 | 7 | 1985.64 | 32 | 15.04 | 3049 | 1467 | 1.72 / 23.81 | 3 | 3 |
4 | 13 | 1421.52 | 18 | 15.12 | 2317 | 631 | 2.35 / 24.44 | 2 | 3 |
5 | 13 | 877.56 | 18 | 15.21 | 1570 | 430 | 2.78 / 24.87 | 2 | 3 |
6 | 13 | 164.16 | 18 | 15.37 | 526 | 146 | 2.92 / 25.02 | 3 | 3 |
7 | 8 | 0.12 | 165 | 15.37 | 275 | 697 | 3.62 / 25.72 | 3 | 8 |
Average= | 3.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.28 | 27 | 15.31 | 438 | 181 | 0.18 / 18.57 | 3 | 3 |
2 | 3 | 1043.32 | 1 | 15.35 | 1866 | 29 | 0.21 / 18.60 | 3 | 3 |
3 | 7 | 2003.32 | 38 | 15.00 | 3061 | 1745 | 1.95 / 20.35 | 3 | 3 |
4 | 13 | 1258.36 | 18 | 15.15 | 2091 | 570 | 2.52 / 20.92 | 2 | 3 |
5 | 13 | 703.68 | 18 | 15.25 | 1311 | 360 | 2.88 / 21.28 | 3 | 3 |
6 | 13 | 122.60 | 18 | 15.37 | 463 | 128 | 3.01 / 21.40 | 3 | 3 |
7 | 8 | 0.08 | 165 | 15.36 | 273 | 692 | 3.70 / 22.10 | 3 | 9 |
Average= | 3.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.36 | 26 | 15.34 | 430 | 172 | 0.17 / 14.76 | 3 | 3 |
2 | 3 | 1027.60 | 1 | 15.37 | 1836 | 28 | 0.20 / 14.79 | 3 | 3 |
3 | 7 | 2004.32 | 38 | 15.01 | 3064 | 1748 | 1.95 / 16.54 | 3 | 3 |
4 | 13 | 1388.24 | 18 | 15.13 | 2260 | 615 | 2.56 / 17.16 | 2 | 3 |
5 | 13 | 802.44 | 18 | 15.22 | 1448 | 397 | 2.96 / 17.55 | 2 | 3 |
6 | 13 | 178.56 | 18 | 15.36 | 541 | 150 | 3.11 / 17.70 | 3 | 3 |
7 | 8 | 0.00 | 165 | 15.36 | 272 | 689 | 3.80 / 18.39 | 3 | 6 |
Average= | 3.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.16 | 27 | 15.33 | 434 | 180 | 0.18 / 11.57 | 3 | 3 |
2 | 7 | 1507.28 | 38 | 15.17 | 2393 | 1379 | 1.56 / 12.95 | 3 | 3 |
3 | 13 | 1118.92 | 18 | 15.22 | 1885 | 516 | 2.08 / 13.47 | 2 | 3 |
4 | 13 | 672.92 | 18 | 15.29 | 1260 | 347 | 2.42 / 13.81 | 2 | 3 |
5 | 13 | 44.36 | 18 | 15.41 | 340 | 94 | 2.52 / 13.91 | 3 | 3 |
6 | 8 | 0.12 | 165 | 15.38 | 270 | 685 | 3.20 / 14.59 | 3 | 11 |
Average= | 2.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.00 | 27 | 15.33 | 437 | 181 | 0.18 / 8.34 | 3 | 3 |
2 | 7 | 1506.76 | 38 | 15.17 | 2390 | 1378 | 1.56 / 9.72 | 3 | 3 |
3 | 13 | 1236.16 | 18 | 15.20 | 2043 | 559 | 2.12 / 10.28 | 3 | 3 |
4 | 13 | 629.84 | 18 | 15.30 | 1197 | 330 | 2.45 / 10.61 | 3 | 3 |
5 | 13 | 35.36 | 18 | 15.41 | 330 | 92 | 2.54 / 10.70 | 3 | 3 |
6 | 8 | 0.08 | 165 | 15.38 | 272 | 690 | 3.23 / 11.39 | 3 | 11 |
Average= | 2.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.08 | 28 | 15.33 | 439 | 188 | 0.19 / 4.68 | 3 | 3 |
2 | 3 | 958.76 | -1 | 15.66 | 0 | 0 | 0.00 / 4.68 | 3 | 3 |
3 | 7 | 1518.40 | 74 | 15.07 | 2398 | 2674 | 2.86 / 7.35 | 3 | 3 |
4 | 13 | 110.96 | 18 | 15.39 | 441 | 122 | 2.98 / 7.48 | 3 | 3 |
5 | 8 | 0.12 | 165 | 15.38 | 270 | 685 | 3.67 / 8.16 | 3 | 8 |
Average= | 2.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.00 | 24 | 15.50 | 413 | 154 | 0.15 / 1.83 | 3 | 3 |
2 | 10 | 1021.44 | 2 | 15.37 | 1805 | 55 | 0.21 / 1.88 | 3 | 3 |
3 | 7 | 1005.60 | 74 | 15.22 | 1693 | 1907 | 2.12 / 3.79 | 3 | 4 |
4 | 8 | 0.00 | 165 | 15.40 | 276 | 701 | 2.82 / 4.49 | 3 | 9 |
Average= | 2.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 163.08 | 24 | 15.63 | 498 | 187 | 0.19 / 0.19 | 3 | 3 |
2 | 7 | 175.12 | 74 | 15.59 | 499 | 576 | 0.76 / 0.76 | 3 | 3 |
3 | 8 | 0.24 | 240 | 15.57 | 244 | 912 | 1.67 / 1.67 | 3 | 13 |
Average= | 1.67 (KJ/cycle) |