1 | 2 | 111.08 | 92 | 10.17 | 349 | 327 | 0.33 / 1921.64 | 6 | 6 |
2 | 3 | 1060.68 | 3 | 7.49 | 1026 | 23 | 0.35 / 1921.66 | 5 | 5 |
3 | 7 | 2007.52 | 105 | 4.96 | 1618 | 843 | 1.19 / 1922.50 | 5 | 6 |
4 | 13 | 2041.48 | 36 | 4.88 | 1643 | 289 | 1.48 / 1922.79 | 5 | 6 |
5 | 13 | 2021.76 | 36 | 4.80 | 1633 | 282 | 1.76 / 1923.07 | 5 | 6 |
6 | 13 | 1988.28 | 36 | 4.82 | 1604 | 278 | 2.04 / 1923.35 | 5 | 6 |
7 | 13 | 1949.80 | 36 | 4.79 | 1583 | 273 | 2.31 / 1923.62 | 5 | 6 |
8 | 13 | 1904.72 | 36 | 4.86 | 1552 | 272 | 2.59 / 1923.90 | 5 | 6 |
9 | 13 | 1849.20 | 36 | 4.83 | 1526 | 265 | 2.85 / 1924.16 | 5 | 6 |
10 | 13 | 1797.44 | 36 | 4.89 | 1497 | 264 | 3.11 / 1924.42 | 5 | 6 |
11 | 13 | 1734.00 | 36 | 5.01 | 1451 | 262 | 3.38 / 1924.69 | 5 | 6 |
12 | 13 | 1656.88 | 36 | 5.23 | 1398 | 263 | 3.64 / 1924.95 | 5 | 6 |
13 | 13 | 1576.96 | 36 | 5.39 | 1350 | 262 | 3.90 / 1925.21 | 5 | 5 |
14 | 13 | 1490.48 | 36 | 5.50 | 1299 | 257 | 4.16 / 1925.47 | 5 | 5 |
15 | 13 | 1394.24 | 36 | 5.78 | 1237 | 257 | 4.42 / 1925.73 | 5 | 5 |
16 | 13 | 1296.80 | 36 | 6.01 | 1169 | 253 | 4.67 / 1925.98 | 5 | 5 |
17 | 13 | 1198.60 | 36 | 6.23 | 1107 | 248 | 4.92 / 1926.23 | 5 | 5 |
18 | 13 | 890.52 | 36 | 7.14 | 903 | 232 | 5.15 / 1926.46 | 5 | 5 |
19 | 13 | 487.24 | 36 | 8.46 | 624 | 190 | 5.34 / 1926.65 | 5 | 6 |
20 | 13 | 88.04 | 36 | 9.83 | 336 | 119 | 5.46 / 1926.77 | 5 | 6 |
21 | 8 | -0.16 | 183 | 10.20 | 270 | 504 | 5.96 / 1927.27 | 5 | 8 |
22 | 14 | -0.20 | 42 | 10.23 | 264 | 113 | 6.08 / 1927.39 | 5 | 7 |
Average= | 21.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.56 | 90 | 10.28 | 346 | 320 | 0.32 / 1915.77 | 6 | 6 |
2 | 3 | 1038.76 | 2 | 7.78 | 1017 | 16 | 0.34 / 1915.79 | 5 | 5 |
3 | 7 | 2006.28 | 106 | 5.29 | 1635 | 917 | 1.25 / 1916.71 | 5 | 5 |
4 | 13 | 1996.56 | 36 | 5.29 | 1641 | 313 | 1.57 / 1917.02 | 5 | 5 |
5 | 13 | 1957.04 | 36 | 5.34 | 1614 | 310 | 1.88 / 1917.33 | 5 | 5 |
6 | 13 | 1904.88 | 36 | 5.45 | 1576 | 309 | 2.18 / 1917.64 | 5 | 5 |
7 | 13 | 1845.64 | 36 | 5.49 | 1538 | 304 | 2.49 / 1917.94 | 5 | 5 |
8 | 13 | 1789.28 | 36 | 5.55 | 1504 | 300 | 2.79 / 1918.24 | 5 | 5 |
9 | 13 | 1717.40 | 36 | 5.66 | 1463 | 298 | 3.09 / 1918.54 | 5 | 5 |
10 | 13 | 1629.68 | 36 | 5.85 | 1401 | 295 | 3.38 / 1918.84 | 5 | 5 |
11 | 13 | 1534.32 | 36 | 5.96 | 1341 | 288 | 3.67 / 1919.12 | 5 | 5 |
12 | 13 | 1345.32 | 36 | 6.42 | 1219 | 282 | 3.95 / 1919.41 | 5 | 5 |
13 | 13 | 1247.92 | 36 | 6.65 | 1161 | 278 | 4.23 / 1919.68 | 5 | 5 |
14 | 13 | 1051.32 | 36 | 7.12 | 1026 | 263 | 4.49 / 1919.95 | 5 | 5 |
15 | 13 | 734.80 | 36 | 7.95 | 816 | 234 | 4.73 / 1920.18 | 5 | 5 |
16 | 13 | 517.60 | 36 | 8.64 | 660 | 205 | 4.93 / 1920.39 | 5 | 6 |
17 | 13 | 38.48 | 36 | 10.13 | 304 | 111 | 5.04 / 1920.50 | 5 | 6 |
18 | 8 | -0.12 | 290 | 10.30 | 272 | 812 | 5.85 / 1921.31 | 5 | 11 |
Average= | 21.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.68 | 89 | 10.30 | 348 | 319 | 0.32 / 1909.95 | 5 | 6 |
2 | 3 | 1026.96 | 1 | 8.11 | 1020 | 8 | 0.33 / 1909.96 | 5 | 5 |
3 | 7 | 2010.60 | 105 | 5.58 | 1648 | 966 | 1.29 / 1910.92 | 5 | 5 |
4 | 13 | 1982.72 | 36 | 5.59 | 1647 | 331 | 1.62 / 1911.25 | 5 | 5 |
5 | 13 | 1937.76 | 36 | 5.67 | 1610 | 329 | 1.95 / 1911.58 | 5 | 5 |
6 | 13 | 1882.92 | 36 | 5.80 | 1569 | 328 | 2.28 / 1911.91 | 5 | 5 |
7 | 13 | 1816.68 | 36 | 5.83 | 1533 | 322 | 2.60 / 1912.23 | 5 | 5 |
8 | 13 | 1744.84 | 36 | 5.95 | 1486 | 318 | 2.92 / 1912.55 | 5 | 5 |
9 | 13 | 1661.60 | 36 | 6.14 | 1439 | 318 | 3.24 / 1912.87 | 5 | 5 |
10 | 13 | 1463.48 | 36 | 6.54 | 1306 | 307 | 3.55 / 1913.18 | 5 | 5 |
11 | 13 | 1370.04 | 36 | 6.71 | 1249 | 302 | 3.85 / 1913.48 | 5 | 5 |
12 | 13 | 1174.88 | 36 | 7.13 | 1119 | 287 | 4.14 / 1913.77 | 5 | 5 |
13 | 13 | 974.44 | 36 | 7.63 | 978 | 269 | 4.40 / 1914.03 | 5 | 5 |
14 | 13 | 656.44 | 36 | 8.43 | 765 | 232 | 4.64 / 1914.27 | 5 | 5 |
15 | 13 | 234.88 | 36 | 9.65 | 459 | 159 | 4.80 / 1914.43 | 5 | 6 |
16 | 8 | -0.08 | 363 | 10.38 | 273 | 1029 | 5.82 / 1915.45 | 5 | 21 |
Average= | 21.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.16 | 88 | 10.36 | 353 | 322 | 0.32 / 1904.07 | 5 | 6 |
2 | 3 | 1021.84 | 1 | 8.32 | 1002 | 8 | 0.33 / 1904.07 | 5 | 5 |
3 | 7 | 2009.32 | 106 | 5.86 | 1643 | 1021 | 1.35 / 1905.09 | 5 | 5 |
4 | 13 | 1987.84 | 36 | 5.94 | 1650 | 353 | 1.70 / 1905.45 | 5 | 5 |
5 | 13 | 1945.84 | 36 | 6.03 | 1611 | 350 | 2.05 / 1905.80 | 5 | 5 |
6 | 13 | 1890.48 | 36 | 6.09 | 1578 | 346 | 2.40 / 1906.14 | 5 | 5 |
7 | 13 | 1814.12 | 36 | 6.09 | 1543 | 338 | 2.74 / 1906.48 | 5 | 5 |
8 | 13 | 1723.32 | 36 | 6.34 | 1482 | 338 | 3.08 / 1906.82 | 5 | 5 |
9 | 13 | 1630.16 | 36 | 6.48 | 1414 | 330 | 3.41 / 1907.15 | 5 | 5 |
10 | 13 | 1537.92 | 36 | 6.65 | 1350 | 323 | 3.73 / 1907.47 | 5 | 5 |
11 | 13 | 1251.76 | 36 | 7.25 | 1170 | 305 | 4.03 / 1907.78 | 5 | 5 |
12 | 13 | 958.56 | 36 | 7.88 | 972 | 276 | 4.31 / 1908.05 | 5 | 5 |
13 | 13 | 760.12 | 36 | 8.34 | 842 | 253 | 4.56 / 1908.31 | 5 | 6 |
14 | 13 | 437.96 | 36 | 9.20 | 609 | 202 | 4.76 / 1908.51 | 5 | 7 |
15 | 8 | 0.08 | 398 | 10.45 | 270 | 1123 | 5.89 / 1909.63 | 5 | 14 |
Average= | 21.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.00 | 88 | 10.44 | 339 | 311 | 0.31 / 1898.19 | 5 | 6 |
2 | 7 | 2005.28 | 105 | 6.05 | 1646 | 1046 | 1.36 / 1899.23 | 6 | 5 |
3 | 13 | 1985.20 | 36 | 6.16 | 1644 | 365 | 1.72 / 1899.60 | 5 | 5 |
4 | 13 | 1938.84 | 36 | 6.28 | 1609 | 364 | 2.09 / 1899.96 | 5 | 5 |
5 | 13 | 1878.60 | 36 | 6.39 | 1572 | 362 | 2.45 / 1900.32 | 5 | 5 |
6 | 13 | 1806.40 | 36 | 6.39 | 1532 | 352 | 2.80 / 1900.68 | 5 | 5 |
7 | 13 | 1715.08 | 36 | 6.56 | 1472 | 348 | 3.15 / 1901.02 | 5 | 5 |
8 | 13 | 1525.04 | 36 | 6.95 | 1352 | 338 | 3.49 / 1901.36 | 5 | 5 |
9 | 13 | 1427.16 | 36 | 7.07 | 1293 | 329 | 3.81 / 1901.69 | 5 | 5 |
10 | 13 | 1122.32 | 36 | 7.72 | 1084 | 301 | 4.12 / 1901.99 | 5 | 5 |
11 | 13 | 1023.52 | 36 | 7.94 | 1017 | 291 | 4.41 / 1902.28 | 5 | 5 |
12 | 13 | 493.96 | 36 | 9.18 | 649 | 214 | 4.62 / 1902.50 | 5 | 7 |
13 | 13 | 41.20 | 36 | 10.34 | 305 | 114 | 4.73 / 1902.61 | 5 | 6 |
14 | 8 | -0.08 | 399 | 10.50 | 270 | 1131 | 5.87 / 1903.74 | 5 | 18 |
Average= | 22.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.48 | 87 | 10.44 | 352 | 320 | 0.32 / 1892.23 | 5 | 6 |
2 | 3 | 1018.92 | 1 | 8.51 | 1004 | 9 | 0.33 / 1892.24 | 5 | 5 |
3 | 7 | 2014.12 | 105 | 6.25 | 1651 | 1083 | 1.41 / 1893.32 | 5 | 5 |
4 | 13 | 1997.24 | 36 | 6.36 | 1652 | 378 | 1.79 / 1893.70 | 5 | 5 |
5 | 13 | 1940.84 | 36 | 6.45 | 1611 | 374 | 2.16 / 1894.07 | 5 | 5 |
6 | 13 | 1858.40 | 36 | 6.55 | 1563 | 369 | 2.53 / 1894.44 | 5 | 5 |
7 | 13 | 1769.84 | 36 | 6.69 | 1508 | 363 | 2.90 / 1894.81 | 5 | 5 |
8 | 13 | 1685.88 | 36 | 6.84 | 1457 | 359 | 3.25 / 1895.16 | 5 | 5 |
9 | 13 | 1600.12 | 36 | 6.99 | 1398 | 352 | 3.61 / 1895.52 | 5 | 5 |
10 | 13 | 1302.88 | 36 | 7.55 | 1209 | 329 | 3.93 / 1895.85 | 5 | 5 |
11 | 13 | 1210.80 | 36 | 7.68 | 1151 | 318 | 4.25 / 1896.16 | 5 | 5 |
12 | 13 | 897.16 | 36 | 8.36 | 931 | 280 | 4.53 / 1896.44 | 5 | 6 |
13 | 13 | 362.12 | 36 | 9.63 | 543 | 188 | 4.72 / 1896.63 | 5 | 8 |
14 | 8 | 0.16 | 435 | 10.53 | 272 | 1246 | 5.97 / 1897.88 | 5 | 15 |
Average= | 22.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.64 | 87 | 10.49 | 345 | 315 | 0.31 / 1886.27 | 5 | 6 |
2 | 7 | 2006.36 | 106 | 6.42 | 1653 | 1125 | 1.44 / 1887.39 | 5 | 5 |
3 | 13 | 1977.20 | 36 | 6.51 | 1652 | 387 | 1.83 / 1887.78 | 5 | 5 |
4 | 13 | 1916.92 | 36 | 6.63 | 1603 | 383 | 2.21 / 1888.16 | 5 | 5 |
5 | 13 | 1843.12 | 36 | 6.74 | 1563 | 379 | 2.59 / 1888.54 | 5 | 5 |
6 | 13 | 1763.28 | 36 | 6.86 | 1521 | 376 | 2.96 / 1888.92 | 5 | 5 |
7 | 13 | 1673.00 | 36 | 6.96 | 1453 | 364 | 3.33 / 1889.28 | 5 | 5 |
8 | 13 | 1575.00 | 36 | 7.21 | 1391 | 361 | 3.69 / 1889.64 | 5 | 5 |
9 | 13 | 1275.20 | 36 | 7.72 | 1196 | 332 | 4.02 / 1889.97 | 5 | 5 |
10 | 13 | 1077.56 | 36 | 8.08 | 1070 | 311 | 4.33 / 1890.28 | 5 | 5 |
11 | 13 | 661.52 | 36 | 8.95 | 776 | 250 | 4.58 / 1890.53 | 5 | 7 |
12 | 13 | 149.00 | 36 | 10.18 | 388 | 142 | 4.73 / 1890.68 | 5 | 7 |
13 | 8 | -0.24 | 434 | 10.57 | 269 | 1234 | 5.96 / 1891.91 | 5 | 17 |
Average= | 22.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.52 | 87 | 10.49 | 352 | 321 | 0.32 / 1880.32 | 5 | 5 |
2 | 7 | 2003.04 | 105 | 6.56 | 1654 | 1139 | 1.46 / 1881.46 | 5 | 5 |
3 | 13 | 1945.52 | 36 | 6.79 | 1624 | 397 | 1.86 / 1881.86 | 5 | 5 |
4 | 13 | 1875.52 | 36 | 6.83 | 1586 | 390 | 2.25 / 1882.25 | 5 | 5 |
5 | 13 | 1801.12 | 36 | 7.01 | 1547 | 390 | 2.64 / 1882.64 | 5 | 5 |
6 | 13 | 1720.68 | 36 | 7.10 | 1492 | 381 | 3.02 / 1883.02 | 5 | 5 |
7 | 13 | 1638.36 | 36 | 7.23 | 1430 | 372 | 3.39 / 1883.39 | 5 | 5 |
8 | 13 | 1541.28 | 36 | 7.41 | 1372 | 366 | 3.76 / 1883.76 | 5 | 5 |
9 | 13 | 1116.20 | 36 | 8.11 | 1105 | 323 | 4.08 / 1884.08 | 5 | 5 |
10 | 13 | 915.52 | 36 | 8.52 | 958 | 294 | 4.37 / 1884.38 | 5 | 6 |
11 | 13 | 388.76 | 36 | 9.67 | 575 | 200 | 4.57 / 1884.58 | 5 | 8 |
12 | 13 | 20.40 | 36 | 10.50 | 294 | 111 | 4.69 / 1884.69 | 5 | 7 |
13 | 8 | -0.04 | 435 | 10.59 | 274 | 1262 | 5.95 / 1885.95 | 5 | 13 |
Average= | 22.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.48 | 87 | 10.53 | 355 | 325 | 0.33 / 1874.34 | 5 | 6 |
2 | 7 | 2003.40 | 105 | 6.70 | 1660 | 1168 | 1.49 / 1875.51 | 6 | 5 |
3 | 13 | 1961.16 | 36 | 6.84 | 1643 | 405 | 1.90 / 1875.92 | 5 | 5 |
4 | 13 | 1896.56 | 36 | 6.97 | 1602 | 402 | 2.30 / 1876.32 | 5 | 5 |
5 | 13 | 1820.28 | 36 | 7.07 | 1552 | 395 | 2.69 / 1876.71 | 5 | 5 |
6 | 13 | 1724.64 | 36 | 7.25 | 1491 | 389 | 3.08 / 1877.10 | 5 | 5 |
7 | 13 | 1528.28 | 36 | 7.54 | 1369 | 372 | 3.46 / 1877.47 | 5 | 5 |
8 | 13 | 1437.24 | 36 | 7.70 | 1306 | 362 | 3.82 / 1877.84 | 5 | 5 |
9 | 13 | 1238.04 | 36 | 8.01 | 1182 | 341 | 4.16 / 1878.18 | 5 | 5 |
10 | 13 | 719.20 | 36 | 9.00 | 822 | 266 | 4.42 / 1878.44 | 5 | 7 |
11 | 13 | 307.68 | 36 | 9.89 | 516 | 184 | 4.61 / 1878.63 | 5 | 8 |
12 | 13 | 23.92 | 36 | 10.51 | 297 | 112 | 4.72 / 1878.74 | 5 | 7 |
13 | 8 | -0.12 | 435 | 10.61 | 274 | 1265 | 5.99 / 1880.00 | 5 | 15 |
Average= | 22.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.48 | 87 | 10.56 | 344 | 316 | 0.32 / 1868.35 | 5 | 6 |
2 | 7 | 2008.00 | 106 | 6.84 | 1660 | 1204 | 1.52 / 1869.55 | 6 | 5 |
3 | 13 | 1962.60 | 36 | 6.98 | 1640 | 412 | 1.93 / 1869.96 | 5 | 5 |
4 | 13 | 1900.84 | 36 | 7.10 | 1611 | 412 | 2.34 / 1870.37 | 5 | 5 |
5 | 13 | 1824.76 | 36 | 7.18 | 1556 | 402 | 2.75 / 1870.78 | 5 | 5 |
6 | 13 | 1733.44 | 36 | 7.31 | 1507 | 397 | 3.14 / 1871.17 | 5 | 5 |
7 | 13 | 1540.16 | 36 | 7.62 | 1382 | 379 | 3.52 / 1871.55 | 5 | 5 |
8 | 13 | 1247.52 | 36 | 8.13 | 1191 | 349 | 3.87 / 1871.90 | 5 | 5 |
9 | 13 | 1046.28 | 36 | 8.47 | 1051 | 320 | 4.19 / 1872.22 | 5 | 6 |
10 | 13 | 726.72 | 36 | 9.05 | 831 | 271 | 4.46 / 1872.49 | 5 | 7 |
11 | 13 | 314.16 | 36 | 9.93 | 525 | 188 | 4.65 / 1872.68 | 5 | 8 |
12 | 8 | 0.32 | 450 | 10.62 | 280 | 1338 | 5.99 / 1874.02 | 5 | 17 |
Average= | 23.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.92 | 86 | 10.57 | 348 | 316 | 0.32 / 1862.39 | 5 | 6 |
2 | 7 | 2008.20 | 105 | 6.93 | 1665 | 1212 | 1.53 / 1863.60 | 5 | 5 |
3 | 13 | 1974.76 | 36 | 7.12 | 1648 | 422 | 1.95 / 1864.02 | 5 | 5 |
4 | 13 | 1913.52 | 36 | 7.15 | 1619 | 417 | 2.37 / 1864.44 | 5 | 5 |
5 | 13 | 1836.24 | 36 | 7.28 | 1571 | 412 | 2.78 / 1864.85 | 5 | 5 |
6 | 13 | 1750.64 | 36 | 7.45 | 1512 | 406 | 3.18 / 1865.26 | 5 | 5 |
7 | 13 | 1657.60 | 36 | 7.54 | 1448 | 393 | 3.58 / 1865.65 | 5 | 5 |
8 | 13 | 1248.68 | 36 | 8.22 | 1189 | 352 | 3.93 / 1866.00 | 5 | 5 |
9 | 13 | 939.20 | 36 | 8.73 | 980 | 308 | 4.24 / 1866.31 | 5 | 6 |
10 | 13 | 642.76 | 36 | 9.30 | 762 | 255 | 4.49 / 1866.57 | 5 | 8 |
11 | 13 | 228.84 | 36 | 10.16 | 459 | 168 | 4.66 / 1866.73 | 5 | 7 |
12 | 8 | -0.12 | 450 | 10.67 | 270 | 1296 | 5.96 / 1868.03 | 5 | 18 |
Average= | 23.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.20 | 86 | 10.57 | 353 | 321 | 0.32 / 1856.51 | 5 | 6 |
2 | 7 | 2015.24 | 106 | 7.03 | 1664 | 1240 | 1.56 / 1857.75 | 6 | 5 |
3 | 13 | 1974.96 | 36 | 7.20 | 1657 | 429 | 1.99 / 1858.18 | 5 | 5 |
4 | 13 | 1911.68 | 36 | 7.29 | 1615 | 424 | 2.41 / 1858.61 | 5 | 5 |
5 | 13 | 1825.68 | 36 | 7.41 | 1557 | 415 | 2.83 / 1859.02 | 5 | 5 |
6 | 13 | 1728.76 | 36 | 7.62 | 1496 | 410 | 3.24 / 1859.43 | 5 | 5 |
7 | 13 | 1631.16 | 36 | 7.75 | 1432 | 400 | 3.64 / 1859.83 | 5 | 5 |
8 | 13 | 1314.28 | 36 | 8.22 | 1232 | 365 | 4.00 / 1860.20 | 5 | 5 |
9 | 13 | 913.88 | 36 | 8.87 | 961 | 307 | 4.31 / 1860.50 | 5 | 6 |
10 | 13 | 602.24 | 36 | 9.44 | 736 | 250 | 4.56 / 1860.75 | 5 | 8 |
11 | 8 | 0.20 | 450 | 10.68 | 275 | 1322 | 5.88 / 1862.07 | 5 | 13 |
Average= | 23.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.48 | 86 | 10.61 | 352 | 321 | 0.32 / 1850.60 | 5 | 6 |
2 | 3 | 1012.56 | 1 | 9.07 | 1017 | 9 | 0.33 / 1850.61 | 5 | 5 |
3 | 7 | 2014.60 | 105 | 7.14 | 1669 | 1251 | 1.58 / 1851.86 | 5 | 5 |
4 | 13 | 1973.28 | 36 | 7.30 | 1662 | 437 | 2.02 / 1852.30 | 5 | 5 |
5 | 13 | 1906.76 | 36 | 7.43 | 1613 | 431 | 2.45 / 1852.73 | 5 | 5 |
6 | 13 | 1826.80 | 36 | 7.50 | 1571 | 424 | 2.87 / 1853.16 | 5 | 5 |
7 | 13 | 1730.24 | 36 | 7.67 | 1505 | 416 | 3.29 / 1853.57 | 5 | 5 |
8 | 13 | 1433.52 | 36 | 8.10 | 1316 | 384 | 3.67 / 1853.95 | 5 | 5 |
9 | 13 | 1032.44 | 36 | 8.73 | 1048 | 329 | 4.00 / 1854.28 | 5 | 6 |
10 | 13 | 729.32 | 36 | 9.23 | 833 | 277 | 4.28 / 1854.56 | 5 | 7 |
11 | 13 | 322.24 | 36 | 10.05 | 528 | 191 | 4.47 / 1854.75 | 5 | 7 |
12 | 13 | 118.36 | 36 | 10.45 | 369 | 139 | 4.61 / 1854.89 | 5 | 7 |
13 | 8 | -0.04 | 450 | 10.71 | 270 | 1301 | 5.91 / 1856.19 | 5 | 23 |
Average= | 23.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.24 | 86 | 10.66 | 345 | 316 | 0.32 / 1844.74 | 5 | 6 |
2 | 7 | 2005.68 | 105 | 7.25 | 1664 | 1267 | 1.58 / 1846.00 | 6 | 5 |
3 | 13 | 1952.64 | 36 | 7.42 | 1637 | 437 | 2.02 / 1846.44 | 5 | 5 |
4 | 13 | 1862.48 | 36 | 7.58 | 1579 | 431 | 2.45 / 1846.87 | 5 | 5 |
5 | 13 | 1775.96 | 36 | 7.69 | 1527 | 423 | 2.87 / 1847.29 | 5 | 5 |
6 | 13 | 1682.28 | 36 | 7.82 | 1469 | 414 | 3.29 / 1847.71 | 5 | 5 |
7 | 13 | 1381.84 | 36 | 8.26 | 1277 | 380 | 3.67 / 1848.09 | 5 | 5 |
8 | 13 | 1184.00 | 36 | 8.56 | 1149 | 354 | 4.02 / 1848.44 | 5 | 5 |
9 | 13 | 985.64 | 36 | 8.84 | 1018 | 324 | 4.35 / 1848.77 | 5 | 6 |
10 | 13 | 427.84 | 36 | 9.87 | 611 | 217 | 4.56 / 1848.98 | 5 | 8 |
11 | 8 | 0.28 | 450 | 10.73 | 269 | 1299 | 5.86 / 1850.28 | 5 | 16 |
Average= | 24.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.60 | 86 | 10.67 | 342 | 314 | 0.31 / 1838.73 | 5 | 6 |
2 | 7 | 2015.56 | 105 | 7.34 | 1667 | 1285 | 1.60 / 1840.01 | 6 | 5 |
3 | 13 | 1967.16 | 36 | 7.50 | 1647 | 445 | 2.04 / 1840.46 | 5 | 5 |
4 | 13 | 1895.44 | 36 | 7.64 | 1612 | 443 | 2.49 / 1840.90 | 5 | 5 |
5 | 13 | 1812.68 | 36 | 7.77 | 1557 | 436 | 2.92 / 1841.34 | 5 | 5 |
6 | 13 | 1714.20 | 36 | 7.88 | 1489 | 422 | 3.34 / 1841.76 | 5 | 5 |
7 | 13 | 1502.72 | 36 | 8.21 | 1349 | 399 | 3.74 / 1842.16 | 5 | 5 |
8 | 13 | 1185.68 | 36 | 8.65 | 1142 | 356 | 4.10 / 1842.51 | 5 | 5 |
9 | 13 | 763.88 | 36 | 9.31 | 850 | 285 | 4.38 / 1842.80 | 5 | 7 |
10 | 13 | 443.48 | 36 | 9.90 | 612 | 218 | 4.60 / 1843.02 | 5 | 8 |
11 | 13 | 9.84 | 36 | 10.69 | 280 | 108 | 4.71 / 1843.12 | 5 | 6 |
12 | 8 | -0.16 | 450 | 10.74 | 268 | 1295 | 6.00 / 1844.42 | 5 | 25 |
Average= | 24.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.80 | 86 | 10.69 | 340 | 313 | 0.31 / 1832.77 | 5 | 6 |
2 | 7 | 2004.08 | 105 | 7.41 | 1672 | 1301 | 1.61 / 1834.07 | 6 | 5 |
3 | 13 | 1949.76 | 36 | 7.61 | 1643 | 450 | 2.06 / 1834.52 | 5 | 5 |
4 | 13 | 1885.04 | 36 | 7.75 | 1596 | 445 | 2.51 / 1834.97 | 5 | 5 |
5 | 13 | 1810.20 | 36 | 7.81 | 1572 | 442 | 2.95 / 1835.41 | 5 | 5 |
6 | 13 | 1714.84 | 36 | 7.97 | 1498 | 430 | 3.38 / 1835.84 | 5 | 5 |
7 | 13 | 1403.60 | 36 | 8.39 | 1301 | 393 | 3.77 / 1836.23 | 5 | 5 |
8 | 13 | 1197.28 | 36 | 8.69 | 1154 | 361 | 4.13 / 1836.59 | 5 | 5 |
9 | 13 | 985.76 | 36 | 9.00 | 1011 | 328 | 4.46 / 1836.92 | 5 | 6 |
10 | 13 | 340.20 | 36 | 10.12 | 536 | 195 | 4.66 / 1837.12 | 5 | 7 |
11 | 8 | 0.12 | 450 | 10.76 | 268 | 1298 | 5.96 / 1838.42 | 5 | 18 |
Average= | 24.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.16 | 86 | 10.72 | 343 | 316 | 0.32 / 1826.93 | 6 | 6 |
2 | 7 | 2004.16 | 105 | 7.50 | 1669 | 1314 | 1.63 / 1828.24 | 6 | 5 |
3 | 13 | 1947.24 | 36 | 7.69 | 1638 | 453 | 2.08 / 1828.70 | 5 | 5 |
4 | 13 | 1867.00 | 36 | 7.83 | 1590 | 448 | 2.53 / 1829.14 | 5 | 5 |
5 | 13 | 1779.20 | 36 | 7.95 | 1534 | 439 | 2.97 / 1829.58 | 5 | 5 |
6 | 13 | 1593.76 | 36 | 8.22 | 1419 | 420 | 3.39 / 1830.00 | 5 | 5 |
7 | 13 | 1292.32 | 36 | 8.59 | 1218 | 377 | 3.77 / 1830.38 | 5 | 5 |
8 | 13 | 1196.60 | 36 | 8.76 | 1154 | 364 | 4.13 / 1830.74 | 5 | 6 |
9 | 13 | 656.88 | 36 | 9.59 | 770 | 266 | 4.40 / 1831.01 | 5 | 8 |
10 | 13 | 126.68 | 36 | 10.53 | 373 | 141 | 4.54 / 1831.15 | 5 | 6 |
11 | 8 | -0.04 | 450 | 10.77 | 270 | 1309 | 5.85 / 1832.46 | 5 | 27 |
Average= | 24.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.84 | 86 | 10.73 | 343 | 317 | 0.32 / 1820.86 | 6 | 6 |
2 | 7 | 2007.96 | 106 | 7.59 | 1671 | 1344 | 1.66 / 1822.21 | 6 | 5 |
3 | 13 | 1957.36 | 36 | 7.75 | 1651 | 461 | 2.12 / 1822.67 | 5 | 5 |
4 | 13 | 1892.44 | 36 | 7.90 | 1615 | 459 | 2.58 / 1823.13 | 5 | 5 |
5 | 13 | 1807.72 | 36 | 7.99 | 1555 | 447 | 3.03 / 1823.57 | 5 | 5 |
6 | 13 | 1615.08 | 36 | 8.25 | 1434 | 426 | 3.45 / 1824.00 | 5 | 5 |
7 | 13 | 1516.88 | 36 | 8.36 | 1368 | 412 | 3.87 / 1824.41 | 5 | 5 |
8 | 13 | 1091.36 | 36 | 8.95 | 1087 | 350 | 4.22 / 1824.76 | 5 | 6 |
9 | 13 | 891.16 | 36 | 9.25 | 947 | 315 | 4.53 / 1825.08 | 5 | 7 |
10 | 13 | 74.88 | 36 | 10.64 | 331 | 127 | 4.66 / 1825.20 | 5 | 6 |
11 | 13 | 18.96 | 36 | 10.73 | 290 | 112 | 4.77 / 1825.32 | 5 | 6 |
12 | 8 | 0.00 | 450 | 10.79 | 267 | 1296 | 6.07 / 1826.61 | 5 | 17 |
Average= | 25.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.16 | 86 | 10.74 | 343 | 317 | 0.32 / 1814.71 | 6 | 6 |
2 | 7 | 2017.08 | 105 | 7.66 | 1680 | 1351 | 1.67 / 1816.06 | 6 | 5 |
3 | 13 | 1962.88 | 36 | 7.81 | 1654 | 465 | 2.13 / 1816.52 | 5 | 5 |
4 | 13 | 1882.08 | 36 | 7.96 | 1597 | 458 | 2.59 / 1816.98 | 5 | 5 |
5 | 13 | 1795.48 | 36 | 8.09 | 1546 | 450 | 3.04 / 1817.43 | 5 | 5 |
6 | 13 | 1701.52 | 36 | 8.22 | 1490 | 441 | 3.48 / 1817.87 | 5 | 5 |
7 | 13 | 1384.52 | 36 | 8.64 | 1279 | 398 | 3.88 / 1818.27 | 5 | 5 |
8 | 13 | 1291.64 | 36 | 8.74 | 1226 | 386 | 4.27 / 1818.66 | 5 | 5 |
9 | 13 | 842.44 | 36 | 9.37 | 915 | 309 | 4.57 / 1818.96 | 5 | 7 |
10 | 13 | 191.08 | 36 | 10.45 | 428 | 161 | 4.74 / 1819.12 | 5 | 6 |
11 | 13 | 43.52 | 36 | 10.71 | 305 | 118 | 4.85 / 1819.24 | 5 | 6 |
12 | 8 | -0.04 | 450 | 10.81 | 268 | 1304 | 6.16 / 1820.55 | 5 | 12 |
Average= | 25.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.36 | 86 | 10.74 | 352 | 325 | 0.33 / 1808.69 | 6 | 6 |
2 | 7 | 2004.28 | 106 | 7.74 | 1676 | 1375 | 1.70 / 1810.06 | 6 | 5 |
3 | 13 | 1945.12 | 36 | 7.91 | 1657 | 472 | 2.17 / 1810.54 | 5 | 5 |
4 | 13 | 1866.28 | 36 | 8.05 | 1602 | 464 | 2.64 / 1811.00 | 5 | 5 |
5 | 13 | 1777.88 | 36 | 8.15 | 1544 | 453 | 3.09 / 1811.45 | 5 | 5 |
6 | 13 | 1682.00 | 36 | 8.31 | 1482 | 443 | 3.53 / 1811.90 | 5 | 5 |
7 | 13 | 1360.44 | 36 | 8.71 | 1275 | 400 | 3.93 / 1812.30 | 5 | 5 |
8 | 13 | 1265.60 | 36 | 8.82 | 1211 | 385 | 4.32 / 1812.68 | 5 | 6 |
9 | 13 | 627.72 | 36 | 9.75 | 763 | 268 | 4.58 / 1812.95 | 5 | 7 |
10 | 13 | 55.76 | 36 | 10.71 | 316 | 122 | 4.71 / 1813.07 | 5 | 6 |
11 | 8 | 0.16 | 450 | 10.82 | 271 | 1319 | 6.03 / 1814.39 | 5 | 17 |
Average= | 25.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.04 | 83 | 10.78 | 342 | 306 | 0.31 / 1802.48 | 6 | 6 |
2 | 10 | 1010.52 | 6 | 9.39 | 1020 | 57 | 0.36 / 1802.53 | 5 | 5 |
3 | 3 | 956.84 | -1 | 9.39 | 1020 | 0 | 0.06 / 1802.53 | 5 | 5 |
4 | 7 | 2018.60 | 105 | 7.76 | 1700 | 1385 | 1.75 / 1803.92 | 5 | 5 |
5 | 13 | 1963.04 | 36 | 8.01 | 1670 | 482 | 2.23 / 1804.40 | 5 | 5 |
6 | 13 | 1887.96 | 36 | 8.10 | 1619 | 472 | 2.70 / 1804.87 | 5 | 5 |
7 | 13 | 1807.04 | 36 | 8.25 | 1562 | 464 | 3.17 / 1805.34 | 5 | 5 |
8 | 13 | 1591.20 | 36 | 8.51 | 1426 | 437 | 3.60 / 1805.77 | 5 | 5 |
9 | 13 | 1502.88 | 36 | 8.61 | 1366 | 423 | 4.03 / 1806.20 | 5 | 5 |
10 | 13 | 964.84 | 36 | 9.28 | 1005 | 336 | 4.36 / 1806.53 | 5 | 7 |
11 | 13 | 756.64 | 36 | 9.60 | 851 | 294 | 4.66 / 1806.83 | 5 | 8 |
12 | 13 | 426.88 | 36 | 10.11 | 606 | 221 | 4.88 / 1807.05 | 5 | 8 |
13 | 8 | 0.08 | 450 | 10.83 | 270 | 1316 | 6.19 / 1808.36 | 5 | 20 |
Average= | 25.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.00 | 83 | 10.80 | 334 | 299 | 0.30 / 1796.43 | 6 | 6 |
2 | 7 | 2007.28 | 105 | 7.85 | 1683 | 1387 | 1.69 / 1797.82 | 6 | 5 |
3 | 13 | 1944.48 | 36 | 8.08 | 1652 | 481 | 2.17 / 1798.30 | 5 | 5 |
4 | 13 | 1870.00 | 36 | 8.19 | 1601 | 472 | 2.64 / 1798.77 | 5 | 5 |
5 | 13 | 1785.96 | 36 | 8.30 | 1551 | 463 | 3.10 / 1799.23 | 5 | 5 |
6 | 13 | 1478.20 | 36 | 8.69 | 1350 | 422 | 3.52 / 1799.65 | 5 | 5 |
7 | 13 | 1383.00 | 36 | 8.80 | 1285 | 407 | 3.93 / 1800.06 | 5 | 6 |
8 | 13 | 1078.04 | 36 | 9.17 | 1082 | 357 | 4.29 / 1800.42 | 5 | 6 |
9 | 13 | 445.28 | 36 | 10.11 | 624 | 227 | 4.52 / 1800.65 | 5 | 8 |
10 | 13 | 354.80 | 36 | 10.25 | 553 | 204 | 4.72 / 1800.85 | 5 | 7 |
11 | 8 | -0.12 | 450 | 10.83 | 271 | 1321 | 6.04 / 1802.17 | 5 | 21 |
Average= | 26.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.56 | 83 | 10.84 | 329 | 296 | 0.30 / 1790.38 | 6 | 6 |
2 | 7 | 2017.36 | 105 | 7.91 | 1693 | 1406 | 1.70 / 1791.79 | 6 | 5 |
3 | 13 | 1975.16 | 36 | 8.10 | 1672 | 488 | 2.19 / 1792.27 | 5 | 5 |
4 | 13 | 1897.28 | 36 | 8.25 | 1622 | 482 | 2.67 / 1792.76 | 5 | 5 |
5 | 13 | 1802.36 | 36 | 8.33 | 1561 | 468 | 3.14 / 1793.22 | 5 | 5 |
6 | 13 | 1709.12 | 36 | 8.48 | 1502 | 459 | 3.60 / 1793.68 | 5 | 5 |
7 | 13 | 1178.40 | 36 | 9.12 | 1153 | 379 | 3.98 / 1794.06 | 5 | 6 |
8 | 13 | 983.76 | 36 | 9.35 | 1024 | 345 | 4.32 / 1794.41 | 5 | 7 |
9 | 13 | 652.32 | 36 | 9.82 | 776 | 274 | 4.60 / 1794.68 | 5 | 8 |
10 | 13 | 51.64 | 36 | 10.74 | 318 | 123 | 4.72 / 1794.80 | 5 | 6 |
11 | 8 | -0.04 | 450 | 10.84 | 272 | 1327 | 6.05 / 1796.13 | 5 | 17 |
Average= | 26.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.00 | 83 | 10.85 | 329 | 296 | 0.30 / 1784.39 | 6 | 6 |
2 | 3 | 1012.64 | 1 | 9.62 | 1015 | 10 | 0.31 / 1784.40 | 5 | 5 |
3 | 7 | 2014.40 | 105 | 8.01 | 1690 | 1421 | 1.73 / 1785.82 | 5 | 5 |
4 | 13 | 1958.68 | 36 | 8.19 | 1662 | 490 | 2.22 / 1786.31 | 5 | 5 |
5 | 13 | 1875.56 | 36 | 8.34 | 1613 | 484 | 2.70 / 1786.79 | 5 | 5 |
6 | 13 | 1777.72 | 36 | 8.46 | 1556 | 474 | 3.18 / 1787.27 | 5 | 5 |
7 | 13 | 1482.28 | 36 | 8.79 | 1352 | 428 | 3.60 / 1787.70 | 5 | 5 |
8 | 13 | 1087.68 | 36 | 9.27 | 1090 | 364 | 3.97 / 1788.06 | 5 | 7 |
9 | 13 | 994.20 | 36 | 9.38 | 1023 | 345 | 4.31 / 1788.41 | 5 | 7 |
10 | 13 | 446.80 | 36 | 10.16 | 625 | 229 | 4.54 / 1788.63 | 5 | 8 |
11 | 13 | 126.04 | 36 | 10.65 | 376 | 144 | 4.69 / 1788.78 | 5 | 7 |
12 | 8 | -0.16 | 450 | 10.87 | 267 | 1306 | 5.99 / 1790.08 | 5 | 20 |
Average= | 26.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.32 | 83 | 10.87 | 331 | 299 | 0.30 / 1778.39 | 6 | 6 |
2 | 7 | 2015.04 | 105 | 8.09 | 1686 | 1432 | 1.73 / 1779.83 | 5 | 5 |
3 | 13 | 1949.20 | 36 | 8.29 | 1661 | 496 | 2.23 / 1780.32 | 5 | 5 |
4 | 13 | 1873.68 | 36 | 8.41 | 1614 | 489 | 2.72 / 1780.81 | 5 | 5 |
5 | 13 | 1783.76 | 36 | 8.49 | 1556 | 476 | 3.19 / 1781.29 | 5 | 5 |
6 | 13 | 1492.44 | 36 | 8.85 | 1370 | 436 | 3.63 / 1781.72 | 5 | 5 |
7 | 13 | 1192.48 | 36 | 9.19 | 1165 | 385 | 4.01 / 1782.11 | 5 | 6 |
8 | 13 | 977.60 | 36 | 9.44 | 1015 | 345 | 4.36 / 1782.45 | 5 | 7 |
9 | 13 | 430.00 | 36 | 10.21 | 614 | 226 | 4.58 / 1782.68 | 5 | 8 |
10 | 13 | 50.72 | 36 | 10.79 | 313 | 122 | 4.70 / 1782.80 | 5 | 6 |
11 | 8 | -0.20 | 450 | 10.89 | 264 | 1294 | 6.00 / 1784.09 | 5 | 11 |
Average= | 27.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.48 | 83 | 10.86 | 336 | 303 | 0.30 / 1772.37 | 6 | 6 |
2 | 7 | 2009.80 | 105 | 8.13 | 1685 | 1438 | 1.74 / 1773.81 | 6 | 5 |
3 | 13 | 1964.76 | 36 | 8.31 | 1673 | 500 | 2.24 / 1774.31 | 5 | 5 |
4 | 13 | 1887.36 | 36 | 8.39 | 1626 | 491 | 2.73 / 1774.80 | 5 | 5 |
5 | 13 | 1793.84 | 36 | 8.50 | 1559 | 477 | 3.21 / 1775.28 | 5 | 5 |
6 | 13 | 1374.36 | 36 | 9.02 | 1294 | 420 | 3.63 / 1775.70 | 5 | 5 |
7 | 13 | 1283.20 | 36 | 9.11 | 1227 | 402 | 4.03 / 1776.10 | 5 | 6 |
8 | 13 | 962.12 | 36 | 9.50 | 1004 | 343 | 4.38 / 1776.45 | 5 | 8 |
9 | 13 | 414.32 | 36 | 10.26 | 597 | 221 | 4.60 / 1776.67 | 5 | 8 |
10 | 13 | 49.04 | 36 | 10.79 | 318 | 124 | 4.72 / 1776.79 | 5 | 6 |
11 | 8 | -0.08 | 450 | 10.89 | 266 | 1304 | 6.02 / 1778.09 | 5 | 14 |
Average= | 27.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.40 | 82 | 10.86 | 336 | 299 | 0.30 / 1766.37 | 6 | 6 |
2 | 7 | 2006.68 | 106 | 8.21 | 1680 | 1462 | 1.76 / 1767.84 | 5 | 5 |
3 | 13 | 1948.24 | 36 | 8.37 | 1650 | 497 | 2.26 / 1768.33 | 5 | 5 |
4 | 13 | 1871.00 | 36 | 8.49 | 1604 | 490 | 2.75 / 1768.82 | 5 | 5 |
5 | 13 | 1781.80 | 36 | 8.65 | 1554 | 484 | 3.23 / 1769.31 | 5 | 5 |
6 | 13 | 1473.84 | 36 | 8.95 | 1355 | 437 | 3.67 / 1769.74 | 5 | 5 |
7 | 13 | 1169.84 | 36 | 9.31 | 1144 | 383 | 4.05 / 1770.13 | 5 | 6 |
8 | 13 | 849.24 | 36 | 9.68 | 918 | 320 | 4.37 / 1770.45 | 5 | 8 |
9 | 13 | 327.72 | 36 | 10.40 | 534 | 200 | 4.57 / 1770.65 | 5 | 8 |
10 | 13 | 55.92 | 36 | 10.78 | 323 | 125 | 4.70 / 1770.77 | 5 | 7 |
11 | 8 | -0.16 | 450 | 10.89 | 265 | 1299 | 6.00 / 1772.07 | 5 | 15 |
Average= | 27.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.36 | 82 | 10.90 | 329 | 294 | 0.29 / 1760.34 | 6 | 6 |
2 | 7 | 2016.24 | 106 | 8.25 | 1687 | 1475 | 1.77 / 1761.82 | 6 | 5 |
3 | 13 | 1951.36 | 36 | 8.46 | 1653 | 503 | 2.27 / 1762.32 | 5 | 5 |
4 | 13 | 1861.16 | 36 | 8.57 | 1607 | 496 | 2.77 / 1762.81 | 5 | 5 |
5 | 13 | 1763.44 | 36 | 8.71 | 1545 | 484 | 3.25 / 1763.30 | 5 | 5 |
6 | 13 | 1566.24 | 36 | 8.94 | 1412 | 454 | 3.71 / 1763.75 | 5 | 5 |
7 | 13 | 1037.36 | 36 | 9.48 | 1058 | 361 | 4.07 / 1764.11 | 5 | 7 |
8 | 13 | 838.72 | 36 | 9.71 | 914 | 319 | 4.39 / 1764.43 | 5 | 8 |
9 | 13 | 407.76 | 36 | 10.30 | 596 | 221 | 4.61 / 1764.66 | 5 | 9 |
10 | 13 | 43.72 | 36 | 10.82 | 306 | 119 | 4.73 / 1764.77 | 5 | 7 |
11 | 8 | -0.12 | 450 | 10.90 | 265 | 1300 | 6.03 / 1766.07 | 5 | 24 |
Average= | 28.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.20 | 82 | 10.91 | 331 | 296 | 0.30 / 1754.32 | 6 | 6 |
2 | 7 | 2011.28 | 105 | 8.33 | 1687 | 1476 | 1.77 / 1755.80 | 6 | 5 |
3 | 13 | 1940.88 | 36 | 8.50 | 1657 | 507 | 2.28 / 1756.30 | 5 | 5 |
4 | 13 | 1857.60 | 36 | 8.63 | 1610 | 500 | 2.78 / 1756.80 | 5 | 5 |
5 | 13 | 1766.36 | 36 | 8.75 | 1546 | 487 | 3.27 / 1757.29 | 5 | 5 |
6 | 13 | 1454.44 | 36 | 9.06 | 1344 | 438 | 3.70 / 1757.73 | 5 | 5 |
7 | 13 | 1248.72 | 36 | 9.29 | 1204 | 403 | 4.11 / 1758.13 | 5 | 6 |
8 | 13 | 716.80 | 36 | 9.89 | 831 | 296 | 4.40 / 1758.43 | 5 | 9 |
9 | 13 | 278.00 | 36 | 10.49 | 500 | 189 | 4.59 / 1758.62 | 5 | 9 |
10 | 13 | 38.40 | 36 | 10.84 | 304 | 119 | 4.71 / 1758.74 | 5 | 7 |
11 | 8 | -0.28 | 450 | 10.91 | 267 | 1311 | 6.02 / 1760.05 | 5 | 16 |
Average= | 28.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.08 | 82 | 10.91 | 333 | 298 | 0.30 / 1748.24 | 6 | 6 |
2 | 7 | 2010.48 | 105 | 8.33 | 1693 | 1481 | 1.78 / 1749.73 | 6 | 5 |
3 | 13 | 1949.36 | 36 | 8.56 | 1651 | 509 | 2.29 / 1750.23 | 5 | 5 |
4 | 13 | 1862.36 | 36 | 8.66 | 1611 | 502 | 2.79 / 1750.74 | 5 | 5 |
5 | 13 | 1670.72 | 36 | 8.89 | 1482 | 474 | 3.26 / 1751.21 | 5 | 5 |
6 | 13 | 1478.08 | 36 | 9.09 | 1357 | 444 | 3.71 / 1751.65 | 5 | 5 |
7 | 13 | 1072.56 | 36 | 9.52 | 1080 | 370 | 4.08 / 1752.03 | 5 | 7 |
8 | 13 | 662.80 | 36 | 9.98 | 795 | 286 | 4.36 / 1752.31 | 5 | 10 |
9 | 13 | 153.08 | 36 | 10.69 | 404 | 155 | 4.52 / 1752.47 | 5 | 7 |
10 | 13 | 30.28 | 36 | 10.85 | 305 | 119 | 4.64 / 1752.59 | 5 | 7 |
11 | 13 | 15.32 | 36 | 10.86 | 296 | 116 | 4.75 / 1752.70 | 5 | 7 |
12 | 8 | -0.36 | 450 | 10.90 | 270 | 1324 | 6.08 / 1754.03 | 5 | 16 |
Average= | 28.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.92 | 82 | 10.91 | 332 | 297 | 0.30 / 1742.22 | 6 | 6 |
2 | 7 | 2011.56 | 105 | 8.40 | 1691 | 1491 | 1.79 / 1743.71 | 6 | 5 |
3 | 13 | 1940.28 | 36 | 8.62 | 1660 | 515 | 2.30 / 1744.22 | 5 | 5 |
4 | 13 | 1842.76 | 36 | 8.74 | 1595 | 502 | 2.81 / 1744.72 | 5 | 5 |
5 | 13 | 1642.60 | 36 | 8.98 | 1461 | 472 | 3.28 / 1745.20 | 5 | 5 |
6 | 13 | 1349.32 | 36 | 9.25 | 1271 | 423 | 3.70 / 1745.62 | 5 | 6 |
7 | 13 | 1037.56 | 36 | 9.58 | 1065 | 367 | 4.07 / 1745.99 | 5 | 7 |
8 | 13 | 737.32 | 36 | 9.92 | 849 | 303 | 4.37 / 1746.29 | 5 | 9 |
9 | 13 | 409.48 | 36 | 10.35 | 601 | 224 | 4.60 / 1746.51 | 5 | 10 |
10 | 13 | 20.32 | 36 | 10.87 | 297 | 116 | 4.71 / 1746.63 | 5 | 7 |
11 | 8 | -0.16 | 450 | 10.92 | 268 | 1317 | 6.03 / 1747.95 | 5 | 20 |
Average= | 29.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.00 | 82 | 10.92 | 342 | 306 | 0.31 / 1736.33 | 6 | 6 |
2 | 7 | 2004.20 | 105 | 8.46 | 1688 | 1499 | 1.81 / 1737.83 | 6 | 5 |
3 | 13 | 1937.92 | 36 | 8.68 | 1658 | 518 | 2.32 / 1738.35 | 5 | 5 |
4 | 13 | 1859.68 | 36 | 8.76 | 1611 | 508 | 2.83 / 1738.86 | 5 | 5 |
5 | 13 | 1569.08 | 36 | 9.06 | 1417 | 462 | 3.29 / 1739.32 | 5 | 5 |
6 | 13 | 1373.08 | 36 | 9.27 | 1285 | 429 | 3.72 / 1739.75 | 5 | 6 |
7 | 13 | 970.52 | 36 | 9.68 | 1016 | 354 | 4.08 / 1740.10 | 5 | 8 |
8 | 13 | 552.12 | 36 | 10.18 | 706 | 259 | 4.34 / 1740.36 | 5 | 9 |
9 | 13 | 65.16 | 36 | 10.83 | 330 | 129 | 4.46 / 1740.49 | 5 | 6 |
10 | 13 | 19.40 | 36 | 10.88 | 295 | 116 | 4.58 / 1740.60 | 5 | 7 |
11 | 8 | -0.28 | 450 | 10.93 | 267 | 1313 | 5.89 / 1741.92 | 5 | 19 |
Average= | 29.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.20 | 82 | 10.94 | 333 | 299 | 0.30 / 1730.29 | 6 | 6 |
2 | 7 | 2012.72 | 106 | 8.52 | 1685 | 1522 | 1.82 / 1731.81 | 6 | 5 |
3 | 13 | 1941.00 | 36 | 8.70 | 1659 | 520 | 2.34 / 1732.33 | 5 | 5 |
4 | 13 | 1847.12 | 36 | 8.80 | 1604 | 508 | 2.85 / 1732.84 | 5 | 5 |
5 | 13 | 1652.76 | 36 | 9.00 | 1477 | 479 | 3.33 / 1733.32 | 5 | 5 |
6 | 13 | 1555.08 | 36 | 9.13 | 1406 | 462 | 3.79 / 1733.78 | 5 | 5 |
7 | 13 | 1121.04 | 36 | 9.56 | 1123 | 386 | 4.18 / 1734.17 | 5 | 7 |
8 | 13 | 501.48 | 36 | 10.26 | 673 | 249 | 4.42 / 1734.42 | 5 | 9 |
9 | 13 | 191.96 | 36 | 10.67 | 432 | 166 | 4.59 / 1734.58 | 5 | 7 |
10 | 13 | 18.00 | 36 | 10.89 | 294 | 115 | 4.71 / 1734.70 | 5 | 7 |
11 | 8 | -0.24 | 450 | 10.93 | 270 | 1328 | 6.03 / 1736.03 | 5 | 18 |
Average= | 29.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.28 | 82 | 10.94 | 334 | 300 | 0.30 / 1724.08 | 6 | 6 |
2 | 7 | 2004.64 | 105 | 8.55 | 1688 | 1515 | 1.82 / 1725.60 | 6 | 5 |
3 | 13 | 1941.88 | 36 | 8.73 | 1662 | 522 | 2.34 / 1726.12 | 5 | 5 |
4 | 13 | 1861.32 | 36 | 8.87 | 1612 | 515 | 2.85 / 1726.64 | 5 | 5 |
5 | 13 | 1767.88 | 36 | 8.93 | 1560 | 502 | 3.35 / 1727.14 | 5 | 5 |
6 | 13 | 1364.64 | 36 | 9.34 | 1291 | 434 | 3.79 / 1727.57 | 5 | 6 |
7 | 13 | 1069.48 | 36 | 9.65 | 1081 | 376 | 4.16 / 1727.95 | 5 | 7 |
8 | 13 | 746.36 | 36 | 9.98 | 853 | 306 | 4.47 / 1728.25 | 5 | 9 |
9 | 13 | 312.24 | 36 | 10.52 | 527 | 200 | 4.67 / 1728.45 | 5 | 8 |
10 | 13 | 19.24 | 36 | 10.90 | 293 | 115 | 4.78 / 1728.57 | 5 | 7 |
11 | 13 | 6.08 | 36 | 10.91 | 284 | 112 | 4.90 / 1728.68 | 5 | 8 |
12 | 8 | -0.16 | 450 | 10.93 | 267 | 1313 | 6.21 / 1729.99 | 5 | 15 |
Average= | 30.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.68 | 82 | 10.92 | 341 | 305 | 0.31 / 1718.03 | 6 | 6 |
2 | 7 | 2008.00 | 105 | 8.58 | 1695 | 1527 | 1.83 / 1719.55 | 6 | 5 |
3 | 13 | 1945.44 | 36 | 8.78 | 1669 | 528 | 2.36 / 1720.08 | 5 | 5 |
4 | 13 | 1854.40 | 36 | 8.90 | 1604 | 514 | 2.87 / 1720.60 | 5 | 5 |
5 | 13 | 1645.68 | 36 | 9.10 | 1476 | 484 | 3.36 / 1721.08 | 5 | 5 |
6 | 13 | 1548.76 | 36 | 9.20 | 1413 | 468 | 3.83 / 1721.55 | 5 | 5 |
7 | 13 | 1030.32 | 36 | 9.71 | 1061 | 371 | 4.20 / 1721.92 | 5 | 8 |
8 | 13 | 624.24 | 36 | 10.15 | 761 | 278 | 4.47 / 1722.20 | 5 | 10 |
9 | 13 | 53.40 | 36 | 10.86 | 325 | 127 | 4.60 / 1722.32 | 5 | 6 |
10 | 13 | 30.20 | 36 | 10.89 | 309 | 121 | 4.72 / 1722.44 | 5 | 6 |
11 | 8 | -0.12 | 450 | 10.94 | 272 | 1339 | 6.06 / 1723.78 | 5 | 17 |
Average= | 30.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.80 | 82 | 10.94 | 340 | 305 | 0.31 / 1712.02 | 6 | 6 |
2 | 7 | 2011.48 | 105 | 8.61 | 1697 | 1534 | 1.84 / 1713.56 | 6 | 5 |
3 | 13 | 1954.88 | 36 | 8.83 | 1662 | 528 | 2.37 / 1714.08 | 5 | 5 |
4 | 13 | 1863.96 | 36 | 8.94 | 1612 | 519 | 2.89 / 1714.60 | 5 | 5 |
5 | 13 | 1564.68 | 36 | 9.22 | 1420 | 471 | 3.36 / 1715.07 | 5 | 6 |
6 | 13 | 1265.80 | 36 | 9.50 | 1223 | 418 | 3.78 / 1715.49 | 5 | 6 |
7 | 13 | 1066.84 | 36 | 9.69 | 1088 | 380 | 4.16 / 1715.87 | 5 | 8 |
8 | 13 | 650.64 | 36 | 10.14 | 786 | 287 | 4.44 / 1716.16 | 5 | 10 |
9 | 13 | 29.56 | 36 | 10.90 | 305 | 120 | 4.56 / 1716.28 | 5 | 6 |
10 | 13 | 17.08 | 36 | 10.91 | 298 | 117 | 4.68 / 1716.40 | 5 | 7 |
11 | 8 | -0.12 | 450 | 10.95 | 269 | 1325 | 6.00 / 1717.72 | 5 | 15 |
Average= | 31.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.36 | 82 | 10.94 | 340 | 305 | 0.31 / 1706.03 | 6 | 6 |
2 | 7 | 2014.32 | 105 | 8.64 | 1700 | 1542 | 1.85 / 1707.57 | 5 | 5 |
3 | 13 | 1952.60 | 36 | 8.89 | 1676 | 536 | 2.38 / 1708.10 | 5 | 5 |
4 | 13 | 1858.56 | 36 | 8.95 | 1612 | 519 | 2.90 / 1708.62 | 5 | 5 |
5 | 13 | 1656.80 | 36 | 9.16 | 1484 | 489 | 3.39 / 1709.11 | 5 | 5 |
6 | 13 | 1348.28 | 36 | 9.46 | 1274 | 434 | 3.83 / 1709.55 | 5 | 6 |
7 | 13 | 939.04 | 36 | 9.86 | 988 | 351 | 4.18 / 1709.90 | 5 | 8 |
8 | 13 | 840.12 | 36 | 9.95 | 924 | 331 | 4.51 / 1710.23 | 5 | 9 |
9 | 13 | 87.88 | 36 | 10.84 | 355 | 139 | 4.65 / 1710.37 | 5 | 7 |
10 | 8 | -0.08 | 450 | 10.95 | 274 | 1350 | 6.00 / 1711.72 | 5 | 17 |
Average= | 31.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.00 | 82 | 10.92 | 340 | 304 | 0.30 / 1700.08 | 5 | 6 |
2 | 7 | 2011.04 | 106 | 8.69 | 1697 | 1563 | 1.87 / 1701.64 | 6 | 5 |
3 | 13 | 1935.00 | 36 | 8.92 | 1656 | 532 | 2.40 / 1702.18 | 5 | 5 |
4 | 13 | 1846.12 | 36 | 9.01 | 1600 | 519 | 2.92 / 1702.70 | 5 | 5 |
5 | 13 | 1753.12 | 36 | 9.11 | 1537 | 504 | 3.42 / 1703.20 | 5 | 5 |
6 | 13 | 1335.44 | 36 | 9.50 | 1261 | 431 | 3.85 / 1703.63 | 5 | 6 |
7 | 13 | 920.16 | 36 | 9.90 | 975 | 347 | 4.20 / 1703.98 | 5 | 8 |
8 | 13 | 616.00 | 36 | 10.22 | 753 | 277 | 4.48 / 1704.26 | 5 | 9 |
9 | 13 | 44.96 | 36 | 10.90 | 317 | 124 | 4.60 / 1704.38 | 5 | 6 |
10 | 8 | 0.00 | 450 | 10.95 | 272 | 1340 | 5.94 / 1705.72 | 5 | 21 |
Average= | 32.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.12 | 82 | 10.92 | 349 | 313 | 0.31 / 1694.09 | 6 | 6 |
2 | 7 | 2011.92 | 106 | 8.71 | 1696 | 1566 | 1.88 / 1695.66 | 6 | 5 |
3 | 13 | 1948.24 | 36 | 8.95 | 1659 | 535 | 2.41 / 1696.19 | 5 | 5 |
4 | 13 | 1858.12 | 36 | 9.03 | 1603 | 521 | 2.93 / 1696.71 | 5 | 5 |
5 | 13 | 1660.76 | 36 | 9.20 | 1486 | 492 | 3.43 / 1697.21 | 5 | 5 |
6 | 13 | 1361.08 | 36 | 9.49 | 1284 | 439 | 3.86 / 1697.64 | 5 | 6 |
7 | 13 | 1041.96 | 36 | 9.80 | 1060 | 374 | 4.24 / 1698.02 | 5 | 8 |
8 | 13 | 629.60 | 36 | 10.21 | 762 | 280 | 4.52 / 1698.30 | 5 | 10 |
9 | 13 | 48.72 | 36 | 10.89 | 320 | 125 | 4.64 / 1698.42 | 5 | 6 |
10 | 8 | -0.12 | 450 | 10.94 | 275 | 1354 | 6.00 / 1699.78 | 5 | 19 |
Average= | 32.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.04 | 82 | 10.91 | 348 | 311 | 0.31 / 1688.09 | 6 | 6 |
2 | 7 | 2013.12 | 106 | 8.71 | 1700 | 1570 | 1.88 / 1689.66 | 6 | 5 |
3 | 13 | 1946.76 | 36 | 9.01 | 1660 | 538 | 2.42 / 1690.20 | 5 | 5 |
4 | 13 | 1862.44 | 36 | 9.05 | 1610 | 525 | 2.94 / 1690.73 | 5 | 5 |
5 | 13 | 1667.84 | 36 | 9.22 | 1492 | 495 | 3.44 / 1691.22 | 5 | 5 |
6 | 13 | 1358.88 | 36 | 9.53 | 1286 | 441 | 3.88 / 1691.66 | 5 | 6 |
7 | 13 | 1053.04 | 36 | 9.79 | 1072 | 378 | 4.26 / 1692.04 | 5 | 8 |
8 | 13 | 526.88 | 36 | 10.33 | 692 | 257 | 4.52 / 1692.30 | 5 | 10 |
9 | 13 | 55.08 | 36 | 10.89 | 327 | 128 | 4.64 / 1692.43 | 5 | 7 |
10 | 8 | -0.20 | 450 | 10.94 | 275 | 1354 | 6.00 / 1693.78 | 5 | 21 |
Average= | 33.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.00 | 82 | 10.89 | 353 | 315 | 0.32 / 1682.16 | 6 | 6 |
2 | 7 | 2003.88 | 105 | 8.72 | 1688 | 1546 | 1.86 / 1683.70 | 5 | 5 |
3 | 13 | 1939.68 | 36 | 8.92 | 1660 | 533 | 2.39 / 1684.24 | 5 | 5 |
4 | 13 | 1853.08 | 36 | 9.06 | 1602 | 523 | 2.92 / 1684.76 | 5 | 5 |
5 | 13 | 1557.12 | 36 | 9.30 | 1423 | 476 | 3.39 / 1685.23 | 5 | 5 |
6 | 13 | 1257.80 | 36 | 9.59 | 1219 | 421 | 3.81 / 1685.65 | 5 | 6 |
7 | 13 | 948.28 | 36 | 9.88 | 1003 | 357 | 4.17 / 1686.01 | 5 | 8 |
8 | 13 | 641.16 | 36 | 10.20 | 777 | 285 | 4.46 / 1686.30 | 5 | 9 |
9 | 13 | 50.60 | 36 | 10.90 | 321 | 126 | 4.58 / 1686.42 | 5 | 7 |
10 | 8 | -0.08 | 450 | 10.94 | 276 | 1359 | 5.94 / 1687.78 | 5 | 16 |
Average= | 33.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.64 | 82 | 10.88 | 358 | 319 | 0.32 / 1676.20 | 5 | 6 |
2 | 7 | 2007.44 | 105 | 8.67 | 1699 | 1547 | 1.87 / 1677.74 | 6 | 5 |
3 | 13 | 1944.52 | 36 | 8.96 | 1660 | 535 | 2.40 / 1678.28 | 5 | 5 |
4 | 13 | 1855.28 | 36 | 9.03 | 1604 | 521 | 2.92 / 1678.80 | 5 | 5 |
5 | 13 | 1651.04 | 36 | 9.22 | 1480 | 491 | 3.41 / 1679.29 | 5 | 5 |
6 | 13 | 1343.52 | 36 | 9.50 | 1276 | 436 | 3.85 / 1679.73 | 5 | 6 |
7 | 13 | 932.28 | 36 | 9.89 | 984 | 350 | 4.20 / 1680.08 | 5 | 8 |
8 | 13 | 626.84 | 36 | 10.22 | 766 | 282 | 4.48 / 1680.36 | 5 | 10 |
9 | 13 | 48.80 | 36 | 10.89 | 321 | 126 | 4.61 / 1680.49 | 5 | 6 |
10 | 8 | -0.04 | 450 | 10.94 | 275 | 1354 | 5.96 / 1681.84 | 5 | 11 |
Average= | 34.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.44 | 82 | 10.90 | 349 | 312 | 0.31 / 1670.16 | 5 | 6 |
2 | 7 | 2012.12 | 106 | 8.60 | 1701 | 1551 | 1.86 / 1671.71 | 6 | 5 |
3 | 13 | 1936.60 | 36 | 8.86 | 1661 | 530 | 2.39 / 1672.24 | 5 | 5 |
4 | 13 | 1842.68 | 36 | 8.98 | 1604 | 519 | 2.91 / 1672.76 | 5 | 5 |
5 | 13 | 1745.40 | 36 | 9.07 | 1533 | 501 | 3.41 / 1673.26 | 5 | 5 |
6 | 13 | 1330.72 | 36 | 9.47 | 1267 | 432 | 3.84 / 1673.69 | 5 | 6 |
7 | 13 | 1026.84 | 36 | 9.76 | 1062 | 373 | 4.22 / 1674.07 | 5 | 7 |
8 | 13 | 708.68 | 36 | 10.10 | 834 | 303 | 4.52 / 1674.37 | 5 | 9 |
9 | 13 | 92.16 | 36 | 10.83 | 356 | 139 | 4.66 / 1674.51 | 5 | 6 |
10 | 8 | -0.04 | 450 | 10.92 | 279 | 1371 | 6.03 / 1675.88 | 5 | 15 |
Average= | 34.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.88 | 74 | 10.95 | 344 | 279 | 0.28 / 1664.04 | 5 | 6 |
2 | 10 | 1008.56 | 6 | 10.25 | 1022 | 63 | 0.34 / 1664.10 | 5 | 5 |
3 | 3 | 1040.32 | 2 | 10.23 | 1062 | 22 | 0.36 / 1664.12 | 5 | 5 |
4 | 7 | 2011.36 | 105 | 8.42 | 1690 | 1494 | 1.86 / 1665.61 | 5 | 5 |
5 | 13 | 1945.08 | 36 | 8.75 | 1669 | 526 | 2.38 / 1666.14 | 5 | 5 |
6 | 13 | 1862.72 | 36 | 8.90 | 1615 | 517 | 2.90 / 1666.66 | 5 | 5 |
7 | 13 | 1765.60 | 36 | 9.10 | 1542 | 505 | 3.41 / 1667.16 | 5 | 5 |
8 | 13 | 1362.60 | 36 | 9.49 | 1277 | 436 | 3.84 / 1667.60 | 5 | 6 |
9 | 13 | 1052.52 | 36 | 9.79 | 1078 | 380 | 4.22 / 1667.98 | 5 | 8 |
10 | 13 | 849.52 | 36 | 10.01 | 925 | 333 | 4.56 / 1668.31 | 5 | 9 |
11 | 13 | 196.40 | 36 | 10.73 | 438 | 169 | 4.72 / 1668.48 | 5 | 7 |
12 | 8 | 0.16 | 450 | 10.93 | 278 | 1367 | 6.09 / 1669.85 | 5 | 21 |
Average= | 35.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.16 | 67 | 11.75 | 359 | 283 | 0.28 / 1658.07 | 5 | 6 |
2 | 10 | 1035.72 | 5 | 11.60 | 1068 | 62 | 0.34 / 1658.14 | 5 | 5 |
3 | 3 | 1046.00 | 2 | 11.52 | 1097 | 25 | 0.37 / 1658.16 | 5 | 5 |
4 | 7 | 2007.92 | 105 | 8.86 | 1695 | 1577 | 1.95 / 1659.74 | 5 | 5 |
5 | 13 | 1943.00 | 36 | 9.35 | 1670 | 562 | 2.51 / 1660.30 | 5 | 5 |
6 | 13 | 1852.52 | 36 | 9.42 | 1612 | 547 | 3.06 / 1660.85 | 5 | 5 |
7 | 13 | 1651.60 | 36 | 9.58 | 1488 | 513 | 3.57 / 1661.36 | 5 | 5 |
8 | 13 | 1353.60 | 36 | 9.82 | 1279 | 452 | 4.02 / 1661.81 | 5 | 6 |
9 | 13 | 821.68 | 36 | 10.24 | 915 | 337 | 4.36 / 1662.15 | 5 | 9 |
10 | 13 | 507.36 | 36 | 10.55 | 678 | 258 | 4.62 / 1662.41 | 5 | 10 |
11 | 8 | -0.20 | 450 | 10.99 | 273 | 1350 | 5.97 / 1663.76 | 5 | 19 |
Average= | 36.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.80 | 64 | 12.65 | 365 | 296 | 0.30 / 1651.95 | 5 | 5 |
2 | 3 | 1060.28 | 3 | 12.51 | 1127 | 42 | 0.34 / 1651.99 | 5 | 5 |
3 | 7 | 2004.28 | 105 | 8.60 | 1692 | 1528 | 1.87 / 1653.52 | 5 | 5 |
4 | 13 | 1934.32 | 36 | 9.76 | 1679 | 590 | 2.46 / 1654.11 | 5 | 5 |
5 | 13 | 1842.72 | 36 | 9.88 | 1619 | 576 | 3.03 / 1654.69 | 5 | 5 |
6 | 13 | 1744.44 | 36 | 9.96 | 1558 | 559 | 3.59 / 1655.25 | 5 | 6 |
7 | 13 | 1223.68 | 36 | 10.50 | 1206 | 456 | 4.05 / 1655.70 | 5 | 8 |
8 | 13 | 913.64 | 36 | 10.78 | 992 | 385 | 4.43 / 1656.09 | 5 | 11 |
9 | 13 | 363.76 | 36 | 11.38 | 581 | 238 | 4.67 / 1656.33 | 5 | 12 |
10 | 8 | 0.12 | 450 | 11.55 | 282 | 1466 | 6.13 / 1657.79 | 5 | 23 |
Average= | 36.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.20 | 62 | 13.47 | 363 | 303 | 0.30 / 1645.62 | 5 | 6 |
2 | 3 | 1047.48 | 2 | 12.85 | 1110 | 29 | 0.33 / 1645.65 | 5 | 5 |
3 | 7 | 2005.08 | 105 | 7.50 | 1665 | 1311 | 1.64 / 1646.96 | 5 | 5 |
4 | 13 | 1964.08 | 36 | 9.96 | 1695 | 608 | 2.25 / 1647.57 | 5 | 5 |
5 | 13 | 1888.92 | 36 | 10.18 | 1653 | 606 | 2.86 / 1648.17 | 5 | 5 |
6 | 13 | 1594.12 | 36 | 10.64 | 1468 | 562 | 3.42 / 1648.74 | 5 | 7 |
7 | 13 | 1290.04 | 36 | 10.97 | 1260 | 498 | 3.92 / 1649.23 | 5 | 10 |
8 | 13 | 869.56 | 36 | 11.48 | 970 | 401 | 4.32 / 1649.63 | 5 | 15 |
9 | 13 | 556.24 | 36 | 11.83 | 738 | 314 | 4.63 / 1649.95 | 5 | 17 |
10 | 13 | 20.12 | 36 | 12.58 | 319 | 144 | 4.78 / 1650.09 | 5 | 11 |
11 | 8 | 0.16 | 450 | 12.20 | 285 | 1565 | 6.34 / 1651.66 | 5 | 28 |
Average= | 37.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.96 | 61 | 14.06 | 374 | 321 | 0.32 / 1639.28 | 5 | 6 |
2 | 7 | 2013.68 | 105 | 7.31 | 1678 | 1288 | 1.61 / 1640.57 | 5 | 5 |
3 | 13 | 1970.68 | 36 | 10.25 | 1693 | 625 | 2.23 / 1641.19 | 5 | 5 |
4 | 13 | 1896.84 | 36 | 10.42 | 1661 | 623 | 2.86 / 1641.82 | 5 | 5 |
5 | 13 | 1698.64 | 36 | 10.85 | 1547 | 604 | 3.46 / 1642.42 | 5 | 7 |
6 | 13 | 1291.20 | 36 | 11.75 | 1277 | 540 | 4.00 / 1642.96 | 5 | 13 |
7 | 13 | 881.84 | 36 | 12.37 | 987 | 440 | 4.44 / 1643.40 | 5 | 20 |
8 | 13 | 149.64 | 36 | 13.44 | 435 | 210 | 4.65 / 1643.61 | 5 | 15 |
9 | 8 | 0.16 | 450 | 13.02 | 291 | 1705 | 6.36 / 1645.32 | 5 | 28 |
Average= | 38.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.84 | 61 | 14.18 | 391 | 338 | 0.34 / 1632.75 | 5 | 6 |
2 | 7 | 2017.12 | 106 | 7.39 | 1679 | 1315 | 1.65 / 1634.07 | 5 | 5 |
3 | 13 | 1966.24 | 36 | 10.39 | 1714 | 641 | 2.29 / 1634.71 | 5 | 5 |
4 | 13 | 1885.28 | 36 | 10.68 | 1661 | 639 | 2.93 / 1635.34 | 5 | 6 |
5 | 13 | 1589.04 | 36 | 11.77 | 1494 | 633 | 3.57 / 1635.98 | 5 | 10 |
6 | 13 | 1173.84 | 36 | 12.70 | 1210 | 553 | 4.12 / 1636.53 | 5 | 20 |
7 | 13 | 646.28 | 36 | 13.44 | 833 | 403 | 4.52 / 1636.93 | 5 | 27 |
8 | 13 | 109.80 | 36 | 14.06 | 412 | 209 | 4.73 / 1637.14 | 5 | 17 |
9 | 8 | -0.12 | 450 | 13.51 | 299 | 1818 | 6.55 / 1638.96 | 5 | 33 |
Average= | 39.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.52 | 61 | 14.24 | 383 | 333 | 0.33 / 1626.01 | 5 | 6 |
2 | 7 | 2004.72 | 105 | 7.47 | 1666 | 1307 | 1.64 / 1627.31 | 6 | 5 |
3 | 13 | 1955.24 | 36 | 10.60 | 1710 | 653 | 2.29 / 1627.96 | 5 | 5 |
4 | 13 | 1864.28 | 36 | 10.92 | 1667 | 655 | 2.95 / 1628.62 | 5 | 6 |
5 | 13 | 1666.44 | 36 | 11.84 | 1543 | 658 | 3.60 / 1629.28 | 5 | 10 |
6 | 13 | 1352.92 | 36 | 12.74 | 1333 | 611 | 4.22 / 1629.89 | 5 | 19 |
7 | 13 | 792.72 | 36 | 13.47 | 933 | 452 | 4.67 / 1630.34 | 5 | 29 |
8 | 13 | 107.16 | 36 | 14.17 | 411 | 210 | 4.88 / 1630.55 | 5 | 19 |
9 | 8 | -0.08 | 450 | 13.69 | 302 | 1860 | 6.74 / 1632.41 | 5 | 26 |
Average= | 39.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.84 | 59 | 14.28 | 391 | 329 | 0.33 / 1619.51 | 5 | 6 |
2 | 3 | 1032.96 | 2 | 12.84 | 1105 | 28 | 0.36 / 1619.53 | 5 | 5 |
3 | 7 | 2009.64 | 106 | 7.80 | 1684 | 1392 | 1.75 / 1620.93 | 5 | 5 |
4 | 13 | 1948.32 | 36 | 10.88 | 1708 | 669 | 2.42 / 1621.60 | 5 | 6 |
5 | 13 | 1861.36 | 36 | 11.26 | 1653 | 670 | 3.09 / 1622.27 | 5 | 7 |
6 | 13 | 1462.72 | 36 | 12.84 | 1412 | 653 | 3.74 / 1622.92 | 5 | 18 |
7 | 13 | 1055.88 | 36 | 13.33 | 1138 | 546 | 4.29 / 1623.46 | 5 | 25 |
8 | 13 | 431.76 | 36 | 13.90 | 660 | 330 | 4.62 / 1623.79 | 5 | 27 |
9 | 8 | 0.12 | 450 | 13.87 | 301 | 1879 | 6.50 / 1625.67 | 5 | 32 |
Average= | 40.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.56 | 63 | 14.29 | 385 | 347 | 0.35 / 1612.83 | 5 | 6 |
2 | 3 | 963.32 | -1 | 14.29 | 385 | 0 | 0.00 / 1612.83 | 5 | 6 |
3 | 7 | 2005.36 | 105 | 8.13 | 1685 | 1438 | 1.79 / 1614.27 | 6 | 5 |
4 | 13 | 1956.76 | 36 | 11.09 | 1720 | 687 | 2.47 / 1614.96 | 5 | 6 |
5 | 13 | 1876.28 | 36 | 11.58 | 1665 | 694 | 3.17 / 1615.65 | 5 | 7 |
6 | 13 | 1480.88 | 36 | 12.91 | 1424 | 662 | 3.83 / 1616.31 | 5 | 18 |
7 | 13 | 1070.20 | 36 | 13.35 | 1144 | 550 | 4.38 / 1616.86 | 5 | 26 |
8 | 13 | 537.36 | 36 | 13.80 | 754 | 375 | 4.75 / 1617.24 | 5 | 28 |
9 | 8 | 0.00 | 450 | 13.93 | 309 | 1937 | 6.69 / 1619.18 | 5 | 34 |
Average= | 41.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.76 | 63 | 14.29 | 386 | 348 | 0.35 / 1606.12 | 5 | 6 |
2 | 7 | 2006.36 | 105 | 8.21 | 1686 | 1453 | 1.80 / 1607.57 | 6 | 5 |
3 | 13 | 1935.72 | 36 | 11.31 | 1713 | 697 | 2.50 / 1608.27 | 5 | 6 |
4 | 13 | 1849.60 | 36 | 11.86 | 1656 | 707 | 3.21 / 1608.98 | 5 | 8 |
5 | 13 | 1553.24 | 36 | 12.81 | 1473 | 679 | 3.88 / 1609.66 | 5 | 17 |
6 | 13 | 1027.36 | 36 | 13.39 | 1115 | 537 | 4.42 / 1610.19 | 5 | 26 |
7 | 13 | 384.36 | 36 | 13.96 | 622 | 313 | 4.73 / 1610.51 | 5 | 27 |
8 | 8 | 0.16 | 450 | 14.01 | 314 | 1980 | 6.71 / 1612.49 | 5 | 27 |
Average= | 42.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.84 | 63 | 14.32 | 382 | 345 | 0.34 / 1599.39 | 5 | 6 |
2 | 7 | 2003.12 | 105 | 8.42 | 1681 | 1486 | 1.83 / 1600.88 | 6 | 5 |
3 | 13 | 1938.08 | 36 | 11.55 | 1702 | 708 | 2.54 / 1601.59 | 5 | 6 |
4 | 13 | 1849.52 | 36 | 12.06 | 1655 | 719 | 3.26 / 1602.31 | 5 | 9 |
5 | 13 | 1431.44 | 36 | 13.00 | 1394 | 652 | 3.91 / 1602.96 | 5 | 19 |
6 | 13 | 1118.12 | 36 | 13.35 | 1176 | 565 | 4.47 / 1603.52 | 5 | 25 |
7 | 13 | 251.00 | 36 | 14.10 | 523 | 265 | 4.74 / 1603.79 | 5 | 20 |
8 | 8 | 0.04 | 450 | 14.12 | 312 | 1982 | 6.72 / 1605.77 | 5 | 34 |
Average= | 43.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.40 | 63 | 14.31 | 379 | 342 | 0.34 / 1592.51 | 6 | 6 |
2 | 7 | 2004.92 | 105 | 8.40 | 1683 | 1484 | 1.83 / 1593.99 | 6 | 5 |
3 | 13 | 1942.00 | 36 | 11.69 | 1708 | 719 | 2.54 / 1594.71 | 5 | 7 |
4 | 13 | 1864.64 | 36 | 12.18 | 1670 | 732 | 3.28 / 1595.44 | 5 | 9 |
5 | 13 | 1451.40 | 36 | 13.02 | 1396 | 654 | 3.93 / 1596.10 | 5 | 20 |
6 | 13 | 909.56 | 36 | 13.53 | 1023 | 498 | 4.43 / 1596.60 | 5 | 28 |
7 | 13 | 467.68 | 36 | 13.93 | 686 | 344 | 4.77 / 1596.94 | 5 | 26 |
8 | 13 | 5.20 | 36 | 14.30 | 323 | 166 | 4.94 / 1597.11 | 5 | 16 |
9 | 8 | 0.08 | 450 | 14.20 | 304 | 1943 | 6.88 / 1599.05 | 5 | 45 |
Average= | 44.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.76 | 63 | 14.32 | 372 | 336 | 0.34 / 1585.71 | 6 | 6 |
2 | 7 | 2019.36 | 105 | 8.46 | 1693 | 1504 | 1.84 / 1587.21 | 6 | 5 |
3 | 13 | 1964.40 | 36 | 11.81 | 1722 | 732 | 2.57 / 1587.95 | 5 | 7 |
4 | 13 | 1875.56 | 36 | 12.27 | 1673 | 739 | 3.31 / 1588.69 | 5 | 10 |
5 | 13 | 1567.80 | 36 | 12.90 | 1483 | 689 | 4.00 / 1589.37 | 5 | 18 |
6 | 13 | 919.16 | 36 | 13.55 | 1029 | 502 | 4.50 / 1589.88 | 5 | 28 |
7 | 13 | 503.68 | 36 | 13.92 | 705 | 353 | 4.85 / 1590.23 | 5 | 28 |
8 | 8 | -0.12 | 450 | 14.26 | 302 | 1938 | 6.79 / 1592.17 | 5 | 38 |
Average= | 45.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.32 | 63 | 14.34 | 370 | 334 | 0.33 / 1579.09 | 6 | 6 |
2 | 7 | 2006.40 | 105 | 8.44 | 1685 | 1493 | 1.83 / 1580.59 | 6 | 5 |
3 | 13 | 1956.60 | 36 | 11.93 | 1719 | 738 | 2.57 / 1581.32 | 5 | 7 |
4 | 13 | 1867.52 | 36 | 12.32 | 1666 | 739 | 3.30 / 1582.06 | 5 | 9 |
5 | 13 | 1254.88 | 36 | 13.26 | 1268 | 605 | 3.91 / 1582.67 | 5 | 22 |
6 | 13 | 1045.04 | 36 | 13.47 | 1117 | 542 | 4.45 / 1583.21 | 5 | 27 |
7 | 13 | 198.72 | 36 | 14.16 | 471 | 240 | 4.69 / 1583.45 | 5 | 18 |
8 | 8 | -0.08 | 450 | 14.31 | 299 | 1925 | 6.62 / 1585.37 | 5 | 34 |
Average= | 46.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.44 | 63 | 14.32 | 375 | 338 | 0.34 / 1572.36 | 6 | 6 |
2 | 7 | 2012.24 | 106 | 8.46 | 1696 | 1521 | 1.86 / 1573.88 | 6 | 5 |
3 | 13 | 1949.28 | 36 | 12.04 | 1726 | 748 | 2.61 / 1574.62 | 5 | 8 |
4 | 13 | 1860.88 | 36 | 12.39 | 1669 | 744 | 3.35 / 1575.37 | 5 | 10 |
5 | 13 | 1436.84 | 36 | 13.12 | 1390 | 657 | 4.01 / 1576.03 | 5 | 20 |
6 | 13 | 1100.80 | 36 | 13.45 | 1157 | 560 | 4.57 / 1576.59 | 5 | 26 |
7 | 13 | 102.48 | 36 | 14.22 | 406 | 208 | 4.78 / 1576.79 | 5 | 15 |
8 | 8 | -0.16 | 450 | 14.31 | 305 | 1964 | 6.74 / 1578.76 | 5 | 35 |
Average= | 47.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.04 | 63 | 14.32 | 369 | 333 | 0.33 / 1565.28 | 6 | 6 |
2 | 7 | 2005.20 | 105 | 8.53 | 1686 | 1510 | 1.84 / 1566.79 | 6 | 5 |
3 | 13 | 1942.76 | 36 | 12.12 | 1724 | 752 | 2.60 / 1567.54 | 5 | 8 |
4 | 13 | 1854.88 | 36 | 12.41 | 1671 | 747 | 3.34 / 1568.29 | 5 | 11 |
5 | 13 | 1529.68 | 36 | 13.00 | 1458 | 682 | 4.02 / 1568.97 | 5 | 19 |
6 | 13 | 1076.80 | 36 | 13.47 | 1148 | 557 | 4.58 / 1569.52 | 5 | 27 |
7 | 13 | 500.00 | 36 | 13.92 | 710 | 356 | 4.94 / 1569.88 | 5 | 28 |
8 | 13 | 15.68 | 36 | 14.28 | 336 | 173 | 5.11 / 1570.05 | 5 | 14 |
9 | 8 | 0.04 | 450 | 14.31 | 305 | 1964 | 7.07 / 1572.02 | 5 | 36 |
Average= | 49.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.88 | 63 | 14.35 | 373 | 337 | 0.34 / 1558.28 | 6 | 6 |
2 | 7 | 2010.32 | 106 | 8.49 | 1699 | 1529 | 1.87 / 1559.81 | 6 | 5 |
3 | 13 | 1950.60 | 36 | 12.14 | 1732 | 757 | 2.62 / 1560.57 | 5 | 8 |
4 | 13 | 1855.32 | 36 | 12.44 | 1672 | 749 | 3.37 / 1561.32 | 5 | 11 |
5 | 13 | 1644.92 | 36 | 12.86 | 1539 | 712 | 4.08 / 1562.03 | 5 | 17 |
6 | 13 | 1082.88 | 36 | 13.47 | 1154 | 560 | 4.64 / 1562.59 | 5 | 26 |
7 | 13 | 201.88 | 36 | 14.13 | 483 | 246 | 4.89 / 1562.83 | 5 | 18 |
8 | 13 | 6.60 | 36 | 14.28 | 323 | 166 | 5.06 / 1563.00 | 5 | 13 |
9 | 8 | -0.04 | 450 | 14.31 | 302 | 1945 | 7.00 / 1564.94 | 5 | 41 |
Average= | 50.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.88 | 63 | 14.31 | 376 | 339 | 0.34 / 1551.31 | 6 | 6 |
2 | 7 | 2016.80 | 105 | 8.55 | 1692 | 1519 | 1.86 / 1552.82 | 6 | 5 |
3 | 13 | 1961.40 | 36 | 12.18 | 1735 | 761 | 2.62 / 1553.59 | 5 | 8 |
4 | 13 | 1869.68 | 36 | 12.46 | 1675 | 751 | 3.37 / 1554.34 | 5 | 11 |
5 | 13 | 1541.80 | 36 | 13.06 | 1471 | 692 | 4.06 / 1555.03 | 5 | 19 |
6 | 13 | 1004.88 | 36 | 13.56 | 1092 | 533 | 4.59 / 1555.56 | 5 | 28 |
7 | 13 | 161.96 | 36 | 14.16 | 456 | 232 | 4.83 / 1555.79 | 5 | 17 |
8 | 13 | 12.04 | 36 | 14.26 | 339 | 174 | 5.00 / 1555.97 | 5 | 14 |
9 | 8 | -0.04 | 450 | 14.30 | 307 | 1976 | 6.98 / 1557.94 | 5 | 38 |
Average= | 51.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.24 | 63 | 14.31 | 368 | 332 | 0.33 / 1544.59 | 6 | 6 |
2 | 7 | 2008.56 | 105 | 8.48 | 1684 | 1499 | 1.83 / 1546.08 | 6 | 5 |
3 | 13 | 1958.32 | 36 | 12.20 | 1728 | 759 | 2.59 / 1546.84 | 5 | 8 |
4 | 13 | 1864.88 | 36 | 12.46 | 1675 | 751 | 3.34 / 1547.60 | 5 | 11 |
5 | 13 | 1439.88 | 36 | 13.18 | 1402 | 665 | 4.01 / 1548.26 | 5 | 21 |
6 | 13 | 718.92 | 36 | 13.74 | 885 | 438 | 4.44 / 1548.70 | 5 | 30 |
7 | 13 | 295.36 | 36 | 14.05 | 557 | 282 | 4.73 / 1548.98 | 5 | 21 |
8 | 8 | -0.08 | 450 | 14.29 | 309 | 1987 | 6.71 / 1550.97 | 5 | 30 |
Average= | 53.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.76 | 63 | 14.31 | 367 | 331 | 0.33 / 1538.16 | 6 | 6 |
2 | 7 | 1737.40 | 105 | 8.89 | 1515 | 1414 | 1.75 / 1539.57 | 6 | 5 |
3 | 13 | 1691.20 | 36 | 12.34 | 1554 | 690 | 2.44 / 1540.26 | 5 | 11 |
4 | 13 | 1598.80 | 36 | 12.59 | 1499 | 679 | 3.11 / 1540.94 | 5 | 15 |
5 | 13 | 1396.04 | 36 | 13.04 | 1363 | 640 | 3.75 / 1541.58 | 5 | 22 |
6 | 13 | 857.32 | 36 | 13.63 | 989 | 485 | 4.24 / 1542.07 | 5 | 29 |
7 | 13 | 172.44 | 36 | 14.14 | 463 | 236 | 4.48 / 1542.30 | 5 | 17 |
8 | 8 | -0.12 | 450 | 14.30 | 303 | 1950 | 6.43 / 1544.25 | 5 | 52 |
Average= | 55.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.36 | 62 | 14.30 | 370 | 328 | 0.33 / 1531.89 | 6 | 6 |
2 | 3 | 1013.08 | 1 | 12.70 | 1082 | 14 | 0.34 / 1531.90 | 5 | 5 |
3 | 7 | 1596.12 | 106 | 9.08 | 1417 | 1364 | 1.71 / 1533.27 | 5 | 5 |
4 | 13 | 1560.80 | 36 | 12.42 | 1465 | 655 | 2.36 / 1533.92 | 5 | 12 |
5 | 13 | 1482.52 | 36 | 12.66 | 1423 | 649 | 3.01 / 1534.57 | 5 | 16 |
6 | 13 | 1275.92 | 36 | 13.12 | 1285 | 607 | 3.62 / 1535.18 | 5 | 23 |
7 | 13 | 655.00 | 36 | 13.78 | 835 | 414 | 4.03 / 1535.59 | 5 | 29 |
8 | 13 | 317.04 | 36 | 14.04 | 570 | 288 | 4.32 / 1535.88 | 5 | 20 |
9 | 8 | 0.00 | 450 | 14.29 | 303 | 1948 | 6.27 / 1537.83 | 5 | 34 |
Average= | 56.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.68 | 62 | 14.32 | 372 | 330 | 0.33 / 1525.69 | 6 | 6 |
2 | 7 | 1659.92 | 105 | 8.91 | 1466 | 1372 | 1.70 / 1527.06 | 6 | 5 |
3 | 13 | 1615.64 | 36 | 12.41 | 1498 | 669 | 2.37 / 1527.73 | 5 | 12 |
4 | 13 | 1522.12 | 36 | 12.65 | 1445 | 658 | 3.03 / 1528.39 | 5 | 16 |
5 | 13 | 1224.60 | 36 | 13.28 | 1241 | 593 | 3.62 / 1528.98 | 5 | 25 |
6 | 13 | 598.32 | 36 | 13.81 | 787 | 391 | 4.01 / 1529.37 | 5 | 30 |
7 | 13 | 273.40 | 36 | 14.06 | 530 | 268 | 4.28 / 1529.64 | 5 | 22 |
8 | 8 | -0.12 | 450 | 14.29 | 299 | 1923 | 6.20 / 1531.56 | 5 | 38 |
Average= | 58.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.84 | 62 | 14.29 | 373 | 330 | 0.33 / 1518.89 | 6 | 6 |
2 | 7 | 2007.52 | 105 | 8.46 | 1684 | 1496 | 1.83 / 1520.39 | 6 | 5 |
3 | 13 | 1951.48 | 36 | 12.31 | 1724 | 764 | 2.59 / 1521.15 | 5 | 9 |
4 | 13 | 1656.56 | 36 | 12.98 | 1542 | 721 | 3.31 / 1521.87 | 5 | 16 |
5 | 13 | 1563.28 | 36 | 13.08 | 1484 | 699 | 4.01 / 1522.57 | 5 | 19 |
6 | 13 | 864.80 | 36 | 13.65 | 991 | 487 | 4.50 / 1523.06 | 5 | 30 |
7 | 13 | 424.48 | 36 | 13.94 | 651 | 327 | 4.82 / 1523.39 | 5 | 28 |
8 | 8 | -0.16 | 450 | 14.27 | 307 | 1971 | 6.79 / 1525.36 | 5 | 43 |
Average= | 61.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.32 | 62 | 14.29 | 370 | 328 | 0.33 / 1512.17 | 6 | 6 |
2 | 7 | 2015.28 | 105 | 8.51 | 1688 | 1508 | 1.84 / 1513.68 | 6 | 5 |
3 | 13 | 1948.60 | 36 | 12.34 | 1732 | 769 | 2.61 / 1514.45 | 5 | 9 |
4 | 13 | 1850.72 | 36 | 12.59 | 1663 | 754 | 3.36 / 1515.20 | 5 | 12 |
5 | 13 | 1239.36 | 36 | 13.42 | 1259 | 608 | 3.97 / 1515.81 | 5 | 25 |
6 | 13 | 922.04 | 36 | 13.61 | 1045 | 512 | 4.48 / 1516.32 | 5 | 29 |
7 | 13 | 262.40 | 36 | 14.06 | 529 | 268 | 4.75 / 1516.59 | 5 | 26 |
8 | 8 | -0.12 | 450 | 14.26 | 307 | 1970 | 6.72 / 1518.56 | 5 | 33 |
Average= | 63.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.12 | 62 | 14.29 | 377 | 334 | 0.33 / 1505.29 | 6 | 6 |
2 | 7 | 2008.52 | 105 | 8.34 | 1678 | 1469 | 1.80 / 1506.76 | 6 | 5 |
3 | 13 | 1951.60 | 36 | 12.33 | 1727 | 767 | 2.57 / 1507.53 | 5 | 9 |
4 | 13 | 1864.88 | 36 | 12.55 | 1671 | 755 | 3.32 / 1508.28 | 5 | 12 |
5 | 13 | 1550.92 | 36 | 13.14 | 1475 | 698 | 4.02 / 1508.98 | 5 | 20 |
6 | 13 | 804.64 | 36 | 13.68 | 957 | 471 | 4.49 / 1509.45 | 5 | 30 |
7 | 13 | 706.32 | 36 | 13.72 | 874 | 432 | 4.93 / 1509.88 | 5 | 31 |
8 | 8 | -0.12 | 450 | 14.25 | 306 | 1962 | 6.89 / 1511.84 | 5 | 37 |
Average= | 65.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.72 | 62 | 14.28 | 370 | 328 | 0.33 / 1498.34 | 6 | 6 |
2 | 7 | 2004.72 | 105 | 8.32 | 1681 | 1469 | 1.80 / 1499.81 | 6 | 5 |
3 | 13 | 1947.96 | 36 | 12.35 | 1723 | 766 | 2.56 / 1500.57 | 5 | 9 |
4 | 13 | 1861.04 | 36 | 12.58 | 1670 | 756 | 3.32 / 1501.33 | 5 | 11 |
5 | 13 | 1451.60 | 36 | 13.25 | 1408 | 672 | 3.99 / 1502.00 | 5 | 21 |
6 | 13 | 1007.64 | 36 | 13.56 | 1094 | 534 | 4.52 / 1502.54 | 5 | 27 |
7 | 13 | 371.96 | 36 | 13.98 | 610 | 307 | 4.83 / 1502.84 | 5 | 26 |
8 | 13 | 6.64 | 36 | 14.23 | 324 | 166 | 5.00 / 1503.01 | 5 | 18 |
9 | 8 | -0.08 | 450 | 14.24 | 304 | 1948 | 6.95 / 1504.96 | 5 | 46 |
Average= | 68.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.92 | 62 | 14.28 | 375 | 332 | 0.33 / 1491.35 | 6 | 6 |
2 | 7 | 2015.28 | 105 | 8.29 | 1682 | 1464 | 1.80 / 1492.81 | 6 | 5 |
3 | 13 | 1962.28 | 36 | 12.34 | 1733 | 770 | 2.57 / 1493.58 | 5 | 8 |
4 | 13 | 1869.12 | 36 | 12.59 | 1660 | 752 | 3.32 / 1494.33 | 5 | 12 |
5 | 13 | 1668.92 | 36 | 13.01 | 1544 | 723 | 4.04 / 1495.06 | 5 | 18 |
6 | 13 | 1102.48 | 36 | 13.51 | 1167 | 568 | 4.61 / 1495.62 | 5 | 27 |
7 | 13 | 295.12 | 36 | 14.04 | 545 | 275 | 4.88 / 1495.90 | 5 | 22 |
8 | 13 | 15.80 | 36 | 14.22 | 336 | 172 | 5.06 / 1496.07 | 5 | 18 |
9 | 8 | -0.16 | 450 | 14.23 | 303 | 1940 | 7.00 / 1498.01 | 5 | 34 |
Average= | 71.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.36 | 62 | 14.29 | 364 | 322 | 0.32 / 1484.59 | 6 | 6 |
2 | 7 | 2006.68 | 105 | 8.29 | 1677 | 1460 | 1.78 / 1486.05 | 6 | 5 |
3 | 13 | 1950.24 | 36 | 12.36 | 1717 | 764 | 2.55 / 1486.81 | 5 | 8 |
4 | 13 | 1864.20 | 36 | 12.60 | 1667 | 756 | 3.30 / 1487.57 | 5 | 11 |
5 | 13 | 1330.16 | 36 | 13.35 | 1327 | 638 | 3.94 / 1488.20 | 5 | 22 |
6 | 13 | 804.64 | 36 | 13.68 | 950 | 468 | 4.41 / 1488.67 | 5 | 29 |
7 | 13 | 164.48 | 36 | 14.12 | 449 | 228 | 4.64 / 1488.90 | 5 | 19 |
8 | 13 | 30.60 | 36 | 14.20 | 348 | 178 | 4.81 / 1489.08 | 5 | 15 |
9 | 8 | -0.12 | 450 | 14.25 | 302 | 1937 | 6.75 / 1491.01 | 5 | 44 |
Average= | 74.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.40 | 62 | 14.28 | 376 | 333 | 0.33 / 1477.57 | 6 | 6 |
2 | 7 | 2014.40 | 106 | 8.34 | 1683 | 1488 | 1.82 / 1479.06 | 6 | 5 |
3 | 13 | 1959.56 | 36 | 12.36 | 1738 | 773 | 2.59 / 1479.83 | 5 | 9 |
4 | 13 | 1875.08 | 36 | 12.62 | 1677 | 762 | 3.36 / 1480.59 | 5 | 12 |
5 | 13 | 1673.68 | 36 | 13.06 | 1552 | 730 | 4.09 / 1481.32 | 5 | 17 |
6 | 13 | 1013.04 | 36 | 13.57 | 1093 | 534 | 4.62 / 1481.86 | 5 | 27 |
7 | 13 | 464.36 | 36 | 13.92 | 673 | 337 | 4.96 / 1482.19 | 5 | 26 |
8 | 13 | 22.84 | 36 | 14.22 | 335 | 171 | 5.13 / 1482.37 | 5 | 16 |
9 | 8 | -0.04 | 450 | 14.25 | 296 | 1898 | 7.03 / 1484.26 | 5 | 43 |
Average= | 78.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.60 | 62 | 14.25 | 376 | 332 | 0.33 / 1470.66 | 6 | 6 |
2 | 7 | 2008.44 | 106 | 8.38 | 1683 | 1495 | 1.83 / 1472.15 | 5 | 5 |
3 | 13 | 1943.04 | 36 | 12.44 | 1720 | 770 | 2.60 / 1472.92 | 5 | 9 |
4 | 13 | 1844.20 | 36 | 12.70 | 1665 | 761 | 3.36 / 1473.68 | 5 | 12 |
5 | 13 | 1440.80 | 36 | 13.30 | 1400 | 670 | 4.03 / 1474.35 | 5 | 21 |
6 | 13 | 1101.72 | 36 | 13.50 | 1165 | 566 | 4.60 / 1474.92 | 5 | 27 |
7 | 13 | 521.32 | 36 | 13.87 | 729 | 364 | 4.96 / 1475.28 | 5 | 28 |
8 | 8 | -0.12 | 450 | 14.24 | 305 | 1954 | 6.91 / 1477.24 | 5 | 39 |
Average= | 82.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.12 | 62 | 14.23 | 379 | 334 | 0.33 / 1463.82 | 6 | 6 |
2 | 7 | 2005.44 | 105 | 8.48 | 1680 | 1496 | 1.83 / 1465.31 | 6 | 5 |
3 | 13 | 1922.64 | 36 | 12.44 | 1713 | 767 | 2.60 / 1466.08 | 5 | 9 |
4 | 13 | 1827.00 | 36 | 12.71 | 1654 | 757 | 3.35 / 1466.84 | 5 | 13 |
5 | 13 | 1731.92 | 36 | 12.91 | 1594 | 741 | 4.10 / 1467.58 | 5 | 17 |
6 | 13 | 1057.72 | 36 | 13.52 | 1136 | 553 | 4.65 / 1468.13 | 5 | 27 |
7 | 13 | 279.52 | 36 | 14.02 | 546 | 276 | 4.92 / 1468.41 | 5 | 22 |
8 | 8 | 0.04 | 450 | 14.24 | 299 | 1916 | 6.84 / 1470.32 | 5 | 22 |
Average= | 86.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.60 | 62 | 14.21 | 380 | 335 | 0.33 / 1457.10 | 5 | 6 |
2 | 7 | 2010.56 | 105 | 8.39 | 1680 | 1480 | 1.81 / 1458.58 | 6 | 5 |
3 | 13 | 1954.68 | 36 | 12.38 | 1730 | 771 | 2.59 / 1459.35 | 5 | 9 |
4 | 13 | 1856.68 | 36 | 12.64 | 1667 | 759 | 3.34 / 1460.11 | 5 | 12 |
5 | 13 | 1649.00 | 36 | 13.06 | 1535 | 722 | 4.07 / 1460.83 | 5 | 18 |
6 | 13 | 776.52 | 36 | 13.68 | 920 | 453 | 4.52 / 1461.28 | 5 | 29 |
7 | 13 | 253.80 | 36 | 14.04 | 519 | 262 | 4.78 / 1461.55 | 5 | 23 |
8 | 8 | 0.00 | 450 | 14.22 | 303 | 1939 | 6.72 / 1463.48 | 5 | 41 |
Average= | 91.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.72 | 62 | 14.20 | 377 | 332 | 0.33 / 1450.20 | 5 | 6 |
2 | 7 | 2006.64 | 105 | 8.52 | 1680 | 1503 | 1.83 / 1451.70 | 6 | 5 |
3 | 13 | 1938.96 | 36 | 12.43 | 1716 | 768 | 2.60 / 1452.47 | 5 | 9 |
4 | 13 | 1848.20 | 36 | 12.70 | 1660 | 759 | 3.36 / 1453.23 | 5 | 12 |
5 | 13 | 1438.88 | 36 | 13.28 | 1389 | 664 | 4.03 / 1453.89 | 5 | 22 |
6 | 13 | 900.80 | 36 | 13.59 | 1020 | 499 | 4.52 / 1454.39 | 5 | 28 |
7 | 13 | 245.68 | 36 | 14.02 | 512 | 258 | 4.78 / 1454.65 | 5 | 24 |
8 | 13 | 8.88 | 36 | 14.19 | 332 | 170 | 4.95 / 1454.82 | 5 | 17 |
9 | 8 | -0.12 | 450 | 14.18 | 305 | 1946 | 6.90 / 1456.76 | 5 | 37 |
Average= | 97.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.12 | 62 | 14.19 | 379 | 333 | 0.33 / 1443.54 | 5 | 6 |
2 | 7 | 2002.60 | 105 | 8.53 | 1681 | 1506 | 1.84 / 1445.04 | 6 | 5 |
3 | 13 | 1940.44 | 36 | 12.43 | 1716 | 768 | 2.61 / 1445.81 | 5 | 9 |
4 | 13 | 1860.52 | 36 | 12.70 | 1680 | 768 | 3.37 / 1446.58 | 5 | 12 |
5 | 13 | 1320.12 | 36 | 13.34 | 1322 | 635 | 4.01 / 1447.21 | 5 | 23 |
6 | 13 | 800.96 | 36 | 13.64 | 945 | 464 | 4.47 / 1447.68 | 5 | 29 |
7 | 13 | 160.36 | 36 | 14.09 | 448 | 227 | 4.70 / 1447.90 | 5 | 21 |
8 | 8 | -0.04 | 450 | 14.19 | 307 | 1960 | 6.66 / 1449.86 | 5 | 50 |
Average= | 103.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.16 | 62 | 14.18 | 375 | 330 | 0.33 / 1436.91 | 5 | 6 |
2 | 7 | 2011.72 | 105 | 8.54 | 1687 | 1513 | 1.84 / 1438.42 | 6 | 5 |
3 | 13 | 1950.20 | 36 | 12.45 | 1727 | 774 | 2.62 / 1439.19 | 5 | 10 |
4 | 13 | 1855.60 | 36 | 12.75 | 1661 | 762 | 3.38 / 1439.96 | 5 | 13 |
5 | 13 | 1331.24 | 36 | 13.35 | 1312 | 631 | 4.01 / 1440.59 | 5 | 22 |
6 | 13 | 715.48 | 36 | 13.69 | 885 | 436 | 4.45 / 1441.02 | 5 | 29 |
7 | 13 | 187.72 | 36 | 14.06 | 465 | 235 | 4.68 / 1441.26 | 5 | 22 |
8 | 8 | -0.08 | 450 | 14.18 | 305 | 1946 | 6.63 / 1443.20 | 5 | 36 |
Average= | 111.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.08 | 62 | 14.17 | 377 | 331 | 0.33 / 1430.15 | 5 | 6 |
2 | 7 | 2007.32 | 105 | 8.56 | 1680 | 1510 | 1.84 / 1431.66 | 6 | 5 |
3 | 13 | 1942.28 | 36 | 12.49 | 1713 | 770 | 2.61 / 1432.43 | 5 | 9 |
4 | 13 | 1846.72 | 36 | 12.75 | 1657 | 761 | 3.37 / 1433.19 | 5 | 13 |
5 | 13 | 1336.72 | 36 | 13.33 | 1329 | 638 | 4.01 / 1433.82 | 5 | 23 |
6 | 13 | 897.04 | 36 | 13.58 | 1013 | 495 | 4.50 / 1434.32 | 5 | 29 |
7 | 13 | 356.00 | 36 | 13.93 | 607 | 304 | 4.81 / 1434.62 | 5 | 27 |
8 | 8 | 0.00 | 450 | 14.18 | 306 | 1953 | 6.76 / 1436.58 | 5 | 34 |
Average= | 119.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.76 | 62 | 14.16 | 387 | 340 | 0.34 / 1423.42 | 5 | 6 |
2 | 7 | 2014.80 | 105 | 8.50 | 1684 | 1503 | 1.84 / 1424.92 | 6 | 5 |
3 | 13 | 1954.52 | 36 | 12.48 | 1732 | 778 | 2.62 / 1425.70 | 5 | 9 |
4 | 13 | 1862.76 | 36 | 12.75 | 1673 | 768 | 3.39 / 1426.47 | 5 | 13 |
5 | 13 | 1255.80 | 36 | 13.38 | 1267 | 610 | 4.00 / 1427.08 | 5 | 24 |
6 | 13 | 939.96 | 36 | 13.55 | 1043 | 509 | 4.51 / 1427.59 | 5 | 28 |
7 | 13 | 171.16 | 36 | 14.06 | 460 | 233 | 4.74 / 1427.82 | 5 | 24 |
8 | 8 | 0.12 | 450 | 14.17 | 313 | 1996 | 6.74 / 1429.81 | 5 | 38 |
Average= | 129.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.44 | 62 | 14.16 | 379 | 333 | 0.33 / 1416.56 | 5 | 6 |
2 | 7 | 2009.40 | 105 | 8.53 | 1684 | 1508 | 1.84 / 1418.07 | 6 | 5 |
3 | 13 | 1950.52 | 36 | 12.49 | 1729 | 777 | 2.62 / 1418.84 | 5 | 10 |
4 | 13 | 1852.96 | 36 | 12.75 | 1670 | 767 | 3.38 / 1419.61 | 5 | 14 |
5 | 13 | 1541.76 | 36 | 13.19 | 1466 | 696 | 4.08 / 1420.31 | 5 | 21 |
6 | 13 | 1103.24 | 36 | 13.47 | 1165 | 565 | 4.65 / 1420.87 | 5 | 27 |
7 | 13 | 211.80 | 36 | 14.04 | 493 | 249 | 4.90 / 1421.12 | 5 | 21 |
8 | 8 | 0.16 | 450 | 14.17 | 307 | 1958 | 6.85 / 1423.08 | 5 | 42 |
Average= | 142.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.68 | 60 | 14.17 | 376 | 320 | 0.32 / 1409.85 | 5 | 6 |
2 | 3 | 1030.36 | 2 | 13.02 | 1112 | 29 | 0.35 / 1409.88 | 5 | 5 |
3 | 7 | 2009.04 | 105 | 8.56 | 1681 | 1511 | 1.86 / 1411.39 | 5 | 5 |
4 | 13 | 1937.72 | 36 | 12.52 | 1717 | 774 | 2.63 / 1412.17 | 5 | 9 |
5 | 13 | 1848.48 | 36 | 12.79 | 1661 | 765 | 3.40 / 1412.93 | 5 | 13 |
6 | 13 | 1413.68 | 36 | 13.29 | 1370 | 655 | 4.05 / 1413.59 | 5 | 21 |
7 | 13 | 790.24 | 36 | 13.64 | 938 | 461 | 4.51 / 1414.05 | 5 | 28 |
8 | 13 | 151.28 | 36 | 14.08 | 443 | 225 | 4.74 / 1414.27 | 5 | 20 |
9 | 8 | 0.04 | 450 | 14.17 | 306 | 1951 | 6.69 / 1416.23 | 5 | 34 |
Average= | 157.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.80 | 59 | 14.16 | 387 | 323 | 0.32 / 1403.18 | 5 | 6 |
2 | 3 | 1022.08 | 1 | 13.01 | 1100 | 14 | 0.34 / 1403.20 | 5 | 5 |
3 | 7 | 2007.24 | 105 | 8.64 | 1685 | 1529 | 1.87 / 1404.73 | 5 | 5 |
4 | 13 | 1941.20 | 36 | 12.56 | 1706 | 771 | 2.64 / 1405.50 | 5 | 10 |
5 | 13 | 1845.00 | 36 | 12.81 | 1659 | 765 | 3.40 / 1406.26 | 5 | 14 |
6 | 13 | 1323.96 | 36 | 13.35 | 1307 | 628 | 4.03 / 1406.89 | 5 | 23 |
7 | 13 | 885.96 | 36 | 13.58 | 999 | 488 | 4.52 / 1407.38 | 5 | 28 |
8 | 13 | 105.88 | 36 | 14.12 | 401 | 204 | 4.72 / 1407.58 | 5 | 18 |
9 | 8 | 0.00 | 450 | 14.18 | 306 | 1953 | 6.68 / 1409.54 | 5 | 38 |
Average= | 176.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.32 | 62 | 14.11 | 395 | 346 | 0.35 / 1396.42 | 5 | 6 |
2 | 3 | 967.28 | -1 | 14.11 | 395 | 0 | 0.00 / 1396.42 | 5 | 6 |
3 | 7 | 2012.12 | 105 | 8.58 | 1686 | 1519 | 1.86 / 1397.94 | 6 | 5 |
4 | 13 | 1961.04 | 36 | 12.55 | 1734 | 783 | 2.65 / 1398.72 | 5 | 10 |
5 | 13 | 1755.88 | 36 | 13.02 | 1602 | 751 | 3.40 / 1399.47 | 5 | 15 |
6 | 13 | 1349.00 | 36 | 13.34 | 1325 | 636 | 4.04 / 1400.11 | 5 | 23 |
7 | 13 | 1141.92 | 36 | 13.44 | 1186 | 574 | 4.61 / 1400.68 | 5 | 26 |
8 | 13 | 125.24 | 36 | 14.10 | 419 | 213 | 4.82 / 1400.90 | 5 | 18 |
9 | 8 | -0.04 | 450 | 14.17 | 308 | 1964 | 6.79 / 1402.86 | 5 | 33 |
Average= | 200.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.16 | 62 | 14.12 | 380 | 333 | 0.33 / 1389.67 | 5 | 6 |
2 | 7 | 2010.92 | 105 | 8.62 | 1687 | 1527 | 1.86 / 1391.20 | 6 | 5 |
3 | 13 | 1945.00 | 36 | 12.59 | 1716 | 778 | 2.64 / 1391.98 | 5 | 10 |
4 | 13 | 1849.24 | 36 | 12.85 | 1660 | 768 | 3.41 / 1392.74 | 5 | 13 |
5 | 13 | 1339.40 | 36 | 13.33 | 1330 | 638 | 4.04 / 1393.38 | 5 | 23 |
6 | 13 | 814.44 | 36 | 13.62 | 952 | 467 | 4.51 / 1393.85 | 5 | 29 |
7 | 13 | 256.76 | 36 | 13.98 | 516 | 260 | 4.77 / 1394.11 | 5 | 24 |
8 | 8 | 0.24 | 450 | 14.14 | 309 | 1966 | 6.74 / 1396.07 | 5 | 45 |
Average= | 232.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.68 | 62 | 14.12 | 379 | 332 | 0.33 / 1382.82 | 5 | 6 |
2 | 7 | 2014.12 | 105 | 8.66 | 1685 | 1532 | 1.86 / 1384.35 | 6 | 5 |
3 | 13 | 1944.56 | 36 | 12.61 | 1718 | 780 | 2.64 / 1385.13 | 5 | 10 |
4 | 13 | 1850.96 | 36 | 12.86 | 1659 | 768 | 3.41 / 1385.90 | 5 | 14 |
5 | 13 | 1539.40 | 36 | 13.20 | 1453 | 690 | 4.10 / 1386.59 | 5 | 20 |
6 | 13 | 888.76 | 36 | 13.57 | 1009 | 493 | 4.60 / 1387.08 | 5 | 28 |
7 | 13 | 354.08 | 36 | 13.91 | 595 | 298 | 4.89 / 1387.38 | 5 | 26 |
8 | 8 | 0.12 | 450 | 14.14 | 308 | 1960 | 6.85 / 1389.34 | 5 | 30 |
Average= | 277.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.32 | 62 | 14.13 | 368 | 322 | 0.32 / 1376.13 | 5 | 6 |
2 | 7 | 2006.52 | 105 | 8.75 | 1684 | 1547 | 1.87 / 1377.67 | 6 | 5 |
3 | 13 | 1940.92 | 36 | 12.61 | 1715 | 779 | 2.65 / 1378.45 | 5 | 12 |
4 | 13 | 1844.88 | 36 | 12.87 | 1650 | 764 | 3.41 / 1379.22 | 5 | 16 |
5 | 13 | 1306.76 | 36 | 13.34 | 1300 | 624 | 4.04 / 1379.84 | 5 | 23 |
6 | 13 | 881.32 | 36 | 13.57 | 1000 | 489 | 4.53 / 1380.33 | 5 | 29 |
7 | 13 | 111.00 | 36 | 14.10 | 409 | 208 | 4.73 / 1380.54 | 5 | 18 |
8 | 8 | -0.04 | 450 | 14.15 | 306 | 1948 | 6.68 / 1382.48 | 5 | 38 |
Average= | 345.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.32 | 62 | 14.10 | 378 | 330 | 0.33 / 1369.42 | 5 | 6 |
2 | 7 | 2003.84 | 105 | 8.93 | 1672 | 1568 | 1.90 / 1370.99 | 6 | 5 |
3 | 13 | 1930.28 | 36 | 12.64 | 1714 | 780 | 2.68 / 1371.77 | 5 | 11 |
4 | 13 | 1836.04 | 36 | 12.87 | 1650 | 764 | 3.44 / 1372.54 | 5 | 14 |
5 | 13 | 1402.40 | 36 | 13.29 | 1356 | 649 | 4.09 / 1373.19 | 5 | 22 |
6 | 13 | 755.84 | 36 | 13.64 | 897 | 440 | 4.53 / 1373.63 | 5 | 29 |
7 | 13 | 210.24 | 36 | 14.01 | 482 | 243 | 4.77 / 1373.87 | 5 | 23 |
8 | 8 | 0.08 | 450 | 14.14 | 304 | 1934 | 6.71 / 1375.80 | 5 | 41 |
Average= | 458.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.88 | 62 | 14.11 | 378 | 331 | 0.33 / 1362.67 | 5 | 6 |
2 | 7 | 2005.92 | 106 | 8.99 | 1688 | 1609 | 1.94 / 1364.27 | 6 | 5 |
3 | 13 | 1951.64 | 36 | 12.62 | 1718 | 781 | 2.72 / 1365.05 | 5 | 11 |
4 | 13 | 1863.64 | 36 | 12.84 | 1666 | 770 | 3.49 / 1365.82 | 5 | 15 |
5 | 13 | 1349.84 | 36 | 13.32 | 1317 | 632 | 4.12 / 1366.46 | 5 | 23 |
6 | 13 | 1014.36 | 36 | 13.49 | 1087 | 528 | 4.65 / 1366.98 | 5 | 28 |
7 | 13 | 27.64 | 36 | 14.15 | 342 | 174 | 4.82 / 1367.16 | 5 | 17 |
8 | 8 | -0.12 | 450 | 14.15 | 304 | 1936 | 6.76 / 1369.09 | 5 | 41 |
Average= | 684.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.76 | 62 | 14.09 | 376 | 328 | 0.33 / 1355.84 | 5 | 6 |
2 | 7 | 2007.44 | 106 | 8.90 | 1697 | 1601 | 1.93 / 1357.44 | 6 | 5 |
3 | 13 | 1943.48 | 36 | 12.67 | 1711 | 780 | 2.71 / 1358.22 | 5 | 12 |
4 | 13 | 1657.36 | 36 | 13.11 | 1542 | 728 | 3.44 / 1358.95 | 5 | 19 |
5 | 13 | 1560.96 | 36 | 13.16 | 1473 | 698 | 4.14 / 1359.65 | 5 | 20 |
6 | 13 | 664.96 | 36 | 13.69 | 837 | 413 | 4.55 / 1360.06 | 5 | 31 |
7 | 13 | 71.24 | 36 | 14.11 | 379 | 193 | 4.74 / 1360.25 | 5 | 21 |
8 | 13 | 7.60 | 36 | 14.17 | 326 | 166 | 4.91 / 1360.42 | 5 | 19 |
9 | 8 | -0.08 | 450 | 14.16 | 301 | 1918 | 6.82 / 1362.33 | 5 | 45 |
Average= | 1362.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.76 | 62 | 14.10 | 372 | 325 | 0.33 / 1349.17 | 5 | 6 |
2 | 7 | 2011.80 | 106 | 8.97 | 1694 | 1611 | 1.94 / 1350.78 | 5 | 5 |
3 | 13 | 1942.64 | 36 | 12.72 | 1721 | 788 | 2.72 / 1351.56 | 5 | 12 |
4 | 13 | 1747.56 | 36 | 13.07 | 1594 | 750 | 3.47 / 1352.31 | 5 | 17 |
5 | 13 | 1304.80 | 36 | 13.35 | 1297 | 623 | 4.10 / 1352.94 | 5 | 23 |
6 | 13 | 760.56 | 36 | 13.64 | 915 | 449 | 4.55 / 1353.39 | 5 | 30 |
7 | 13 | 99.40 | 36 | 14.10 | 401 | 204 | 4.75 / 1353.59 | 5 | 16 |
8 | 8 | -0.16 | 450 | 14.17 | 301 | 1919 | 6.67 / 1355.51 | 5 | 29 |
Average= | 6.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.80 | 62 | 14.10 | 371 | 324 | 0.32 / 1342.56 | 5 | 6 |
2 | 7 | 2011.48 | 105 | 9.13 | 1692 | 1622 | 1.95 / 1344.18 | 6 | 5 |
3 | 13 | 1938.40 | 36 | 12.72 | 1728 | 791 | 2.74 / 1344.97 | 5 | 13 |
4 | 13 | 1843.72 | 36 | 12.93 | 1663 | 774 | 3.51 / 1345.75 | 5 | 15 |
5 | 13 | 1199.32 | 36 | 13.38 | 1235 | 595 | 4.11 / 1346.34 | 5 | 24 |
6 | 13 | 686.44 | 36 | 13.66 | 865 | 425 | 4.53 / 1346.77 | 5 | 29 |
7 | 13 | 30.68 | 36 | 14.16 | 340 | 173 | 4.71 / 1346.94 | 5 | 14 |
8 | 8 | -0.12 | 450 | 14.18 | 298 | 1902 | 6.61 / 1348.84 | 5 | 46 |
Average= | 6.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.56 | 62 | 14.07 | 373 | 325 | 0.33 / 1335.81 | 5 | 6 |
2 | 7 | 2011.84 | 106 | 9.21 | 1689 | 1649 | 1.97 / 1337.46 | 6 | 5 |
3 | 13 | 1942.00 | 36 | 12.73 | 1723 | 790 | 2.76 / 1338.25 | 5 | 11 |
4 | 13 | 1848.96 | 36 | 12.93 | 1668 | 776 | 3.54 / 1339.03 | 5 | 14 |
5 | 13 | 1403.92 | 36 | 13.29 | 1364 | 653 | 4.19 / 1339.68 | 5 | 22 |
6 | 13 | 645.28 | 36 | 13.69 | 828 | 408 | 4.60 / 1340.09 | 5 | 29 |
7 | 13 | 51.08 | 36 | 14.11 | 369 | 187 | 4.79 / 1340.28 | 5 | 19 |
8 | 8 | 0.08 | 450 | 14.16 | 307 | 1956 | 6.74 / 1342.23 | 5 | 34 |
Average= | 6.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.68 | 62 | 14.06 | 375 | 327 | 0.33 / 1329.14 | 5 | 6 |
2 | 7 | 2011.00 | 106 | 9.33 | 1691 | 1672 | 2.00 / 1330.81 | 6 | 5 |
3 | 13 | 1934.88 | 36 | 12.75 | 1709 | 784 | 2.78 / 1331.60 | 5 | 11 |
4 | 13 | 1734.48 | 36 | 13.06 | 1582 | 744 | 3.53 / 1332.34 | 5 | 17 |
5 | 13 | 1302.84 | 36 | 13.34 | 1300 | 624 | 4.15 / 1332.97 | 5 | 23 |
6 | 13 | 553.24 | 36 | 13.75 | 745 | 369 | 4.52 / 1333.33 | 5 | 30 |
7 | 13 | 57.56 | 36 | 14.10 | 367 | 186 | 4.71 / 1333.52 | 5 | 21 |
8 | 8 | -0.12 | 450 | 14.11 | 310 | 1968 | 6.68 / 1335.49 | 5 | 40 |
Average= | 6.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.60 | 62 | 14.08 | 365 | 319 | 0.32 / 1322.50 | 5 | 6 |
2 | 7 | 2008.20 | 106 | 9.42 | 1685 | 1683 | 2.00 / 1324.18 | 6 | 5 |
3 | 13 | 1931.68 | 36 | 12.79 | 1697 | 781 | 2.78 / 1324.96 | 5 | 13 |
4 | 13 | 1835.48 | 36 | 12.97 | 1633 | 762 | 3.54 / 1325.72 | 5 | 16 |
5 | 13 | 1201.00 | 36 | 13.40 | 1217 | 587 | 4.13 / 1326.31 | 5 | 25 |
6 | 13 | 667.04 | 36 | 13.67 | 829 | 408 | 4.54 / 1326.72 | 5 | 30 |
7 | 13 | 48.40 | 36 | 14.11 | 354 | 180 | 4.72 / 1326.90 | 5 | 20 |
8 | 8 | 0.00 | 450 | 14.14 | 301 | 1915 | 6.64 / 1328.81 | 5 | 32 |
Average= | 6.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.84 | 62 | 14.10 | 367 | 321 | 0.32 / 1315.76 | 5 | 6 |
2 | 7 | 2017.24 | 106 | 9.49 | 1697 | 1707 | 2.03 / 1317.46 | 6 | 5 |
3 | 13 | 1939.48 | 36 | 12.78 | 1717 | 790 | 2.82 / 1318.25 | 5 | 11 |
4 | 13 | 1730.28 | 36 | 13.08 | 1577 | 743 | 3.56 / 1318.99 | 5 | 16 |
5 | 13 | 1218.24 | 36 | 13.38 | 1234 | 594 | 4.15 / 1319.59 | 5 | 24 |
6 | 13 | 899.32 | 36 | 13.55 | 1011 | 493 | 4.65 / 1320.08 | 5 | 28 |
7 | 13 | 57.32 | 36 | 14.11 | 366 | 186 | 4.83 / 1320.27 | 5 | 22 |
8 | 8 | -0.12 | 450 | 14.15 | 300 | 1910 | 6.74 / 1322.18 | 5 | 43 |
Average= | 6.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.88 | 61 | 14.06 | 380 | 326 | 0.33 / 1309.01 | 5 | 6 |
2 | 7 | 2010.40 | 105 | 9.52 | 1703 | 1702 | 2.03 / 1310.72 | 5 | 5 |
3 | 13 | 1945.64 | 36 | 12.80 | 1725 | 795 | 2.82 / 1311.51 | 5 | 11 |
4 | 13 | 1749.84 | 36 | 13.08 | 1602 | 754 | 3.58 / 1312.27 | 5 | 16 |
5 | 13 | 1327.72 | 36 | 13.33 | 1311 | 629 | 4.21 / 1312.89 | 5 | 23 |
6 | 13 | 571.32 | 36 | 13.72 | 780 | 385 | 4.59 / 1313.28 | 5 | 30 |
7 | 13 | 120.16 | 36 | 14.04 | 426 | 215 | 4.81 / 1313.50 | 5 | 23 |
8 | 8 | -0.08 | 450 | 14.13 | 305 | 1939 | 6.75 / 1315.43 | 5 | 36 |
Average= | 6.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.52 | 61 | 14.06 | 375 | 322 | 0.32 / 1302.31 | 5 | 6 |
2 | 7 | 2007.56 | 106 | 9.62 | 1694 | 1727 | 2.05 / 1304.04 | 6 | 5 |
3 | 13 | 1939.68 | 36 | 12.80 | 1715 | 790 | 2.84 / 1304.83 | 5 | 13 |
4 | 13 | 1643.04 | 36 | 13.15 | 1521 | 720 | 3.56 / 1305.55 | 5 | 17 |
5 | 13 | 1321.44 | 36 | 13.33 | 1307 | 627 | 4.19 / 1306.17 | 5 | 23 |
6 | 13 | 660.00 | 36 | 13.67 | 838 | 412 | 4.60 / 1306.59 | 5 | 29 |
7 | 13 | 49.60 | 36 | 14.12 | 360 | 183 | 4.78 / 1306.77 | 5 | 21 |
8 | 8 | 0.20 | 450 | 14.16 | 301 | 1918 | 6.70 / 1308.69 | 5 | 33 |
Average= | 6.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.92 | 61 | 14.04 | 380 | 325 | 0.33 / 1295.46 | 5 | 6 |
2 | 7 | 2012.40 | 106 | 9.68 | 1703 | 1747 | 2.07 / 1297.20 | 6 | 5 |
3 | 13 | 1940.44 | 36 | 12.82 | 1713 | 791 | 2.86 / 1297.99 | 5 | 11 |
4 | 13 | 1630.80 | 36 | 13.16 | 1518 | 719 | 3.58 / 1298.71 | 5 | 18 |
5 | 13 | 1202.08 | 36 | 13.38 | 1229 | 592 | 4.17 / 1299.31 | 5 | 24 |
6 | 13 | 571.48 | 36 | 13.72 | 764 | 377 | 4.55 / 1299.68 | 5 | 30 |
7 | 13 | 63.40 | 36 | 14.10 | 375 | 190 | 4.74 / 1299.87 | 5 | 22 |
8 | 13 | 9.36 | 36 | 14.16 | 330 | 168 | 4.91 / 1300.04 | 5 | 17 |
9 | 8 | -0.32 | 450 | 14.14 | 306 | 1947 | 6.86 / 1301.99 | 5 | 30 |
Average= | 6.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.64 | 61 | 14.07 | 368 | 316 | 0.32 / 1288.71 | 5 | 6 |
2 | 7 | 2012.44 | 106 | 9.75 | 1705 | 1762 | 2.08 / 1290.47 | 6 | 5 |
3 | 13 | 1940.16 | 36 | 12.84 | 1715 | 793 | 2.87 / 1291.26 | 5 | 13 |
4 | 13 | 1639.52 | 36 | 13.16 | 1523 | 722 | 3.59 / 1291.98 | 5 | 19 |
5 | 13 | 1213.80 | 36 | 13.39 | 1227 | 591 | 4.18 / 1292.58 | 5 | 24 |
6 | 13 | 669.16 | 36 | 13.66 | 840 | 413 | 4.60 / 1292.99 | 5 | 31 |
7 | 13 | 47.68 | 36 | 14.10 | 367 | 186 | 4.78 / 1293.17 | 5 | 23 |
8 | 8 | 0.04 | 450 | 14.11 | 308 | 1956 | 6.74 / 1295.13 | 5 | 34 |
Average= | 6.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.36 | 61 | 14.06 | 377 | 323 | 0.32 / 1281.94 | 5 | 6 |
2 | 7 | 2004.76 | 105 | 9.83 | 1691 | 1745 | 2.07 / 1283.69 | 5 | 5 |
3 | 13 | 1935.20 | 36 | 12.85 | 1708 | 790 | 2.86 / 1284.48 | 5 | 12 |
4 | 13 | 1635.12 | 36 | 13.17 | 1510 | 716 | 3.57 / 1285.19 | 5 | 19 |
5 | 13 | 1219.84 | 36 | 13.38 | 1239 | 597 | 4.17 / 1285.79 | 5 | 25 |
6 | 13 | 782.64 | 36 | 13.59 | 929 | 455 | 4.63 / 1286.24 | 5 | 27 |
7 | 13 | 58.76 | 36 | 14.11 | 371 | 188 | 4.81 / 1286.43 | 5 | 24 |
8 | 8 | -0.12 | 450 | 14.13 | 308 | 1958 | 6.77 / 1288.39 | 5 | 38 |
Average= | 6.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.72 | 61 | 14.10 | 372 | 320 | 0.32 / 1275.13 | 5 | 6 |
2 | 7 | 2009.00 | 106 | 9.83 | 1706 | 1778 | 2.10 / 1276.91 | 6 | 5 |
3 | 13 | 1931.52 | 36 | 12.86 | 1720 | 796 | 2.89 / 1277.70 | 5 | 13 |
4 | 13 | 1743.08 | 36 | 13.10 | 1592 | 751 | 3.64 / 1278.45 | 5 | 18 |
5 | 13 | 1305.44 | 36 | 13.34 | 1301 | 625 | 4.27 / 1279.08 | 5 | 23 |
6 | 13 | 654.64 | 36 | 13.66 | 838 | 412 | 4.68 / 1279.49 | 5 | 30 |
7 | 13 | 25.48 | 36 | 14.13 | 346 | 176 | 4.86 / 1279.67 | 5 | 21 |
8 | 8 | 0.00 | 450 | 14.13 | 307 | 1952 | 6.81 / 1281.62 | 5 | 31 |
Average= | 6.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.32 | 61 | 14.04 | 375 | 321 | 0.32 / 1268.41 | 5 | 6 |
2 | 7 | 2011.88 | 106 | 9.91 | 1707 | 1793 | 2.11 / 1270.21 | 6 | 5 |
3 | 13 | 1944.28 | 36 | 12.86 | 1716 | 794 | 2.91 / 1271.00 | 5 | 12 |
4 | 13 | 1551.20 | 36 | 13.21 | 1459 | 694 | 3.60 / 1271.70 | 5 | 19 |
5 | 13 | 1045.68 | 36 | 13.46 | 1112 | 539 | 4.14 / 1272.24 | 5 | 26 |
6 | 13 | 722.72 | 36 | 13.63 | 878 | 431 | 4.57 / 1272.67 | 5 | 30 |
7 | 13 | 33.64 | 36 | 14.13 | 351 | 179 | 4.75 / 1272.84 | 5 | 22 |
8 | 8 | 0.04 | 450 | 14.13 | 309 | 1965 | 6.72 / 1274.81 | 5 | 41 |
Average= | 6.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.96 | 61 | 14.05 | 375 | 321 | 0.32 / 1261.66 | 5 | 6 |
2 | 7 | 2003.40 | 105 | 10.00 | 1695 | 1780 | 2.10 / 1263.44 | 6 | 5 |
3 | 13 | 1913.28 | 36 | 12.89 | 1686 | 782 | 2.88 / 1264.23 | 5 | 14 |
4 | 13 | 1609.12 | 36 | 13.19 | 1495 | 710 | 3.59 / 1264.94 | 5 | 19 |
5 | 13 | 1174.36 | 36 | 13.40 | 1209 | 583 | 4.18 / 1265.52 | 5 | 25 |
6 | 13 | 745.92 | 36 | 13.61 | 893 | 438 | 4.61 / 1265.96 | 5 | 30 |
7 | 13 | 35.32 | 36 | 14.12 | 355 | 180 | 4.79 / 1266.14 | 5 | 24 |
8 | 8 | -0.08 | 450 | 14.12 | 308 | 1957 | 6.75 / 1268.09 | 5 | 41 |
Average= | 6.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.08 | 61 | 14.06 | 371 | 318 | 0.32 / 1254.87 | 5 | 6 |
2 | 7 | 2010.12 | 105 | 10.01 | 1704 | 1791 | 2.11 / 1256.66 | 6 | 5 |
3 | 13 | 1937.00 | 36 | 12.88 | 1725 | 800 | 2.91 / 1257.46 | 5 | 12 |
4 | 13 | 1735.28 | 36 | 13.11 | 1586 | 749 | 3.66 / 1258.21 | 5 | 17 |
5 | 13 | 1286.32 | 36 | 13.35 | 1281 | 616 | 4.27 / 1258.83 | 5 | 24 |
6 | 13 | 618.28 | 36 | 13.68 | 807 | 397 | 4.67 / 1259.23 | 5 | 30 |
7 | 13 | 40.56 | 36 | 14.11 | 361 | 183 | 4.85 / 1259.41 | 5 | 23 |
8 | 8 | -0.12 | 450 | 14.13 | 304 | 1933 | 6.79 / 1261.34 | 5 | 39 |
Average= | 6.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.64 | 61 | 14.09 | 369 | 317 | 0.32 / 1248.17 | 5 | 6 |
2 | 7 | 2009.56 | 105 | 10.04 | 1709 | 1802 | 2.12 / 1249.98 | 6 | 5 |
3 | 13 | 1933.36 | 36 | 12.90 | 1708 | 793 | 2.91 / 1250.77 | 5 | 12 |
4 | 13 | 1541.68 | 36 | 13.23 | 1455 | 693 | 3.60 / 1251.46 | 5 | 19 |
5 | 13 | 1119.32 | 36 | 13.43 | 1157 | 559 | 4.16 / 1252.02 | 5 | 25 |
6 | 13 | 577.56 | 36 | 13.69 | 780 | 384 | 4.55 / 1252.41 | 5 | 30 |
7 | 13 | 62.96 | 36 | 14.09 | 383 | 194 | 4.74 / 1252.60 | 5 | 24 |
8 | 8 | -0.08 | 450 | 14.11 | 308 | 1956 | 6.70 / 1254.56 | 5 | 31 |
Average= | 6.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.24 | 61 | 14.06 | 377 | 323 | 0.32 / 1241.40 | 5 | 6 |
2 | 7 | 2008.16 | 105 | 10.09 | 1705 | 1806 | 2.13 / 1243.21 | 6 | 5 |
3 | 13 | 1932.48 | 36 | 12.90 | 1706 | 792 | 2.92 / 1244.00 | 5 | 12 |
4 | 13 | 1640.56 | 36 | 13.17 | 1519 | 720 | 3.64 / 1244.72 | 5 | 19 |
5 | 13 | 1295.88 | 36 | 13.35 | 1291 | 620 | 4.26 / 1245.34 | 5 | 23 |
6 | 13 | 627.68 | 36 | 13.68 | 809 | 398 | 4.66 / 1245.74 | 5 | 30 |
7 | 13 | 21.92 | 36 | 14.15 | 341 | 174 | 4.83 / 1245.91 | 5 | 21 |
8 | 8 | -0.28 | 450 | 14.13 | 306 | 1946 | 6.78 / 1247.86 | 5 | 25 |
Average= | 6.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.00 | 61 | 14.05 | 375 | 321 | 0.32 / 1234.72 | 5 | 6 |
2 | 7 | 2004.60 | 105 | 10.11 | 1699 | 1804 | 2.12 / 1236.53 | 6 | 5 |
3 | 13 | 1916.32 | 36 | 12.92 | 1692 | 787 | 2.91 / 1237.31 | 5 | 14 |
4 | 13 | 1613.64 | 36 | 13.19 | 1496 | 710 | 3.62 / 1238.03 | 5 | 19 |
5 | 13 | 1090.56 | 36 | 13.44 | 1145 | 554 | 4.18 / 1238.58 | 5 | 26 |
6 | 13 | 562.32 | 36 | 13.71 | 765 | 378 | 4.55 / 1238.96 | 5 | 30 |
7 | 13 | 21.44 | 36 | 14.13 | 344 | 175 | 4.73 / 1239.13 | 5 | 21 |
8 | 8 | -0.16 | 450 | 14.12 | 306 | 1944 | 6.67 / 1241.08 | 5 | 32 |
Average= | 6.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.36 | 61 | 14.03 | 383 | 328 | 0.33 / 1227.87 | 5 | 6 |
2 | 3 | 1012.24 | 1 | 12.99 | 1086 | 14 | 0.34 / 1227.88 | 5 | 5 |
3 | 7 | 2004.12 | 106 | 10.14 | 1709 | 1837 | 2.18 / 1229.72 | 5 | 5 |
4 | 13 | 1924.64 | 36 | 12.93 | 1705 | 794 | 2.97 / 1230.51 | 5 | 14 |
5 | 13 | 1731.56 | 36 | 13.13 | 1586 | 750 | 3.72 / 1231.26 | 5 | 18 |
6 | 13 | 1180.04 | 36 | 13.40 | 1217 | 587 | 4.31 / 1231.85 | 5 | 24 |
7 | 13 | 739.76 | 36 | 13.62 | 891 | 437 | 4.75 / 1232.29 | 5 | 30 |
8 | 13 | 17.80 | 36 | 14.14 | 342 | 174 | 4.92 / 1232.46 | 5 | 20 |
9 | 8 | 0.00 | 450 | 14.14 | 305 | 1941 | 6.86 / 1234.40 | 5 | 33 |
Average= | 6.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.64 | 60 | 14.03 | 374 | 315 | 0.31 / 1221.04 | 5 | 5 |
2 | 3 | 1026.88 | 1 | 13.22 | 1102 | 15 | 0.33 / 1221.05 | 5 | 5 |
3 | 7 | 2016.00 | 105 | 10.15 | 1706 | 1818 | 2.15 / 1222.87 | 5 | 5 |
4 | 13 | 1954.04 | 36 | 12.91 | 1721 | 800 | 2.95 / 1223.67 | 5 | 12 |
5 | 13 | 1658.12 | 36 | 13.17 | 1525 | 723 | 3.67 / 1224.39 | 5 | 18 |
6 | 13 | 1220.64 | 36 | 13.38 | 1228 | 592 | 4.26 / 1224.98 | 5 | 24 |
7 | 13 | 661.60 | 36 | 13.66 | 843 | 415 | 4.68 / 1225.40 | 5 | 30 |
8 | 13 | 19.44 | 36 | 14.14 | 343 | 175 | 4.85 / 1225.57 | 5 | 21 |
9 | 8 | -0.16 | 450 | 14.11 | 310 | 1968 | 6.82 / 1227.54 | 5 | 28 |
Average= | 6.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.08 | 63 | 14.03 | 383 | 339 | 0.34 / 1214.35 | 5 | 5 |
2 | 3 | 965.56 | -1 | 14.03 | 383 | 0 | 0.00 / 1214.35 | 5 | 5 |
3 | 7 | 2008.28 | 106 | 10.14 | 1707 | 1835 | 2.17 / 1216.18 | 5 | 5 |
4 | 13 | 1932.92 | 36 | 12.92 | 1706 | 793 | 2.97 / 1216.97 | 5 | 14 |
5 | 13 | 1625.96 | 36 | 13.18 | 1504 | 714 | 3.68 / 1217.69 | 5 | 19 |
6 | 13 | 1112.76 | 36 | 13.43 | 1161 | 561 | 4.24 / 1218.25 | 5 | 25 |
7 | 13 | 566.80 | 36 | 13.71 | 759 | 375 | 4.62 / 1218.62 | 5 | 29 |
8 | 13 | 22.36 | 36 | 14.13 | 342 | 174 | 4.79 / 1218.80 | 5 | 21 |
9 | 8 | -0.16 | 450 | 14.11 | 303 | 1924 | 6.71 / 1220.72 | 5 | 29 |
Average= | 6.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.40 | 63 | 14.01 | 384 | 339 | 0.34 / 1207.76 | 5 | 6 |
2 | 7 | 2008.12 | 106 | 10.13 | 1705 | 1831 | 2.17 / 1209.59 | 6 | 5 |
3 | 13 | 1935.08 | 36 | 12.90 | 1708 | 793 | 2.96 / 1210.38 | 5 | 13 |
4 | 13 | 1628.32 | 36 | 13.16 | 1521 | 721 | 3.68 / 1211.10 | 5 | 18 |
5 | 13 | 1205.12 | 36 | 13.38 | 1233 | 594 | 4.28 / 1211.70 | 5 | 24 |
6 | 13 | 461.24 | 36 | 13.78 | 690 | 342 | 4.62 / 1212.04 | 5 | 29 |
7 | 8 | 0.16 | 450 | 14.12 | 310 | 1970 | 6.59 / 1214.01 | 5 | 31 |
Average= | 6.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.36 | 63 | 14.08 | 373 | 331 | 0.33 / 1200.94 | 5 | 6 |
2 | 7 | 2007.52 | 105 | 10.16 | 1706 | 1820 | 2.15 / 1202.76 | 6 | 5 |
3 | 13 | 1941.32 | 36 | 12.91 | 1726 | 802 | 2.95 / 1203.56 | 5 | 13 |
4 | 13 | 1847.80 | 36 | 13.03 | 1664 | 781 | 3.73 / 1204.34 | 5 | 16 |
5 | 13 | 1076.64 | 36 | 13.44 | 1144 | 554 | 4.29 / 1204.90 | 5 | 25 |
6 | 13 | 554.00 | 36 | 13.72 | 756 | 373 | 4.66 / 1205.27 | 5 | 27 |
7 | 13 | 25.08 | 36 | 14.15 | 351 | 179 | 4.84 / 1205.45 | 5 | 17 |
8 | 8 | -0.04 | 450 | 14.13 | 310 | 1971 | 6.81 / 1207.42 | 5 | 30 |
Average= | 6.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.32 | 63 | 14.05 | 373 | 330 | 0.33 / 1194.41 | 5 | 5 |
2 | 7 | 2004.40 | 105 | 10.14 | 1716 | 1827 | 2.16 / 1196.24 | 5 | 5 |
3 | 13 | 1925.88 | 36 | 12.92 | 1708 | 794 | 2.95 / 1197.03 | 5 | 13 |
4 | 13 | 1621.60 | 36 | 13.17 | 1515 | 718 | 3.67 / 1197.75 | 5 | 17 |
5 | 13 | 1098.88 | 36 | 13.43 | 1157 | 559 | 4.23 / 1198.31 | 5 | 25 |
6 | 13 | 564.24 | 36 | 13.74 | 753 | 372 | 4.60 / 1198.68 | 5 | 28 |
7 | 8 | 0.20 | 450 | 14.17 | 302 | 1926 | 6.53 / 1200.61 | 5 | 37 |
Average= | 6.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.72 | 63 | 14.04 | 384 | 340 | 0.34 / 1187.74 | 5 | 6 |
2 | 7 | 2009.84 | 105 | 10.16 | 1718 | 1833 | 2.17 / 1189.57 | 6 | 5 |
3 | 13 | 1925.60 | 36 | 12.92 | 1713 | 797 | 2.97 / 1190.37 | 5 | 12 |
4 | 13 | 1519.36 | 36 | 13.22 | 1448 | 689 | 3.66 / 1191.06 | 5 | 19 |
5 | 13 | 1083.16 | 36 | 13.43 | 1148 | 555 | 4.21 / 1191.62 | 5 | 25 |
6 | 13 | 433.08 | 36 | 13.82 | 665 | 331 | 4.54 / 1191.95 | 5 | 26 |
7 | 13 | 18.32 | 36 | 14.17 | 339 | 173 | 4.72 / 1192.12 | 5 | 16 |
8 | 8 | -0.08 | 450 | 14.15 | 308 | 1961 | 6.68 / 1194.08 | 5 | 31 |
Average= | 6.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.12 | 63 | 14.04 | 386 | 341 | 0.34 / 1181.05 | 5 | 5 |
2 | 7 | 2007.12 | 105 | 10.22 | 1712 | 1837 | 2.18 / 1182.89 | 5 | 5 |
3 | 13 | 1939.88 | 36 | 12.93 | 1719 | 800 | 2.98 / 1183.69 | 5 | 13 |
4 | 13 | 1843.24 | 36 | 13.05 | 1657 | 778 | 3.76 / 1184.47 | 5 | 16 |
5 | 13 | 1073.28 | 36 | 13.44 | 1133 | 548 | 4.31 / 1185.02 | 5 | 25 |
6 | 13 | 644.12 | 36 | 13.67 | 829 | 408 | 4.71 / 1185.42 | 5 | 28 |
7 | 8 | 0.12 | 450 | 14.14 | 311 | 1979 | 6.69 / 1187.40 | 5 | 28 |
Average= | 6.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.44 | 62 | 14.03 | 389 | 338 | 0.34 / 1174.31 | 5 | 5 |
2 | 3 | 1014.72 | 1 | 13.00 | 1093 | 14 | 0.35 / 1174.33 | 5 | 5 |
3 | 7 | 2010.36 | 106 | 10.22 | 1725 | 1869 | 2.22 / 1176.20 | 5 | 5 |
4 | 13 | 1929.52 | 36 | 12.94 | 1718 | 800 | 3.02 / 1177.00 | 5 | 13 |
5 | 13 | 1732.56 | 36 | 13.13 | 1584 | 749 | 3.77 / 1177.74 | 5 | 17 |
6 | 13 | 1284.84 | 36 | 13.35 | 1286 | 618 | 4.39 / 1178.36 | 5 | 23 |
7 | 13 | 627.36 | 36 | 13.68 | 810 | 399 | 4.79 / 1178.76 | 5 | 28 |
8 | 8 | 0.20 | 450 | 14.15 | 306 | 1948 | 6.74 / 1180.71 | 5 | 28 |
Average= | 6.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.08 | 62 | 14.05 | 385 | 335 | 0.34 / 1167.89 | 5 | 6 |
2 | 7 | 2012.88 | 105 | 10.26 | 1709 | 1841 | 2.18 / 1169.74 | 6 | 5 |
3 | 13 | 1930.08 | 36 | 12.94 | 1710 | 797 | 2.97 / 1170.53 | 5 | 13 |
4 | 13 | 1513.72 | 36 | 13.23 | 1438 | 685 | 3.66 / 1171.22 | 5 | 19 |
5 | 13 | 980.56 | 36 | 13.48 | 1066 | 517 | 4.18 / 1171.73 | 5 | 26 |
6 | 13 | 343.12 | 36 | 13.90 | 575 | 288 | 4.46 / 1172.02 | 5 | 24 |
7 | 8 | -0.04 | 450 | 14.13 | 307 | 1952 | 6.42 / 1173.97 | 5 | 32 |
Average= | 6.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.68 | 62 | 14.02 | 381 | 331 | 0.33 / 1161.35 | 5 | 5 |
2 | 7 | 2012.72 | 105 | 10.28 | 1708 | 1844 | 2.17 / 1163.20 | 5 | 5 |
3 | 13 | 1930.56 | 36 | 12.93 | 1715 | 798 | 2.97 / 1164.00 | 5 | 13 |
4 | 13 | 1421.80 | 36 | 13.27 | 1376 | 657 | 3.63 / 1164.65 | 5 | 21 |
5 | 13 | 1222.00 | 36 | 13.36 | 1233 | 593 | 4.22 / 1165.25 | 5 | 24 |
6 | 13 | 543.16 | 36 | 13.74 | 742 | 367 | 4.59 / 1165.61 | 5 | 28 |
7 | 8 | 0.12 | 450 | 14.14 | 306 | 1947 | 6.54 / 1167.56 | 5 | 30 |
Average= | 6.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.80 | 62 | 14.06 | 379 | 330 | 0.33 / 1154.78 | 5 | 6 |
2 | 7 | 2004.96 | 106 | 10.26 | 1710 | 1860 | 2.19 / 1156.64 | 6 | 5 |
3 | 13 | 1918.36 | 36 | 12.95 | 1702 | 793 | 2.98 / 1157.43 | 5 | 13 |
4 | 13 | 1502.56 | 36 | 13.23 | 1437 | 684 | 3.67 / 1158.12 | 5 | 19 |
5 | 13 | 1193.16 | 36 | 13.38 | 1214 | 585 | 4.25 / 1158.70 | 5 | 24 |
6 | 13 | 522.96 | 36 | 13.75 | 726 | 359 | 4.61 / 1159.06 | 5 | 28 |
7 | 8 | 0.04 | 450 | 14.13 | 308 | 1958 | 6.57 / 1161.02 | 5 | 28 |
Average= | 6.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.64 | 62 | 14.03 | 382 | 332 | 0.33 / 1148.27 | 5 | 6 |
2 | 7 | 2003.36 | 106 | 10.31 | 1709 | 1868 | 2.20 / 1150.14 | 6 | 5 |
3 | 13 | 1920.52 | 36 | 12.93 | 1706 | 794 | 2.99 / 1150.93 | 5 | 13 |
4 | 13 | 1713.52 | 36 | 13.13 | 1574 | 744 | 3.74 / 1151.68 | 5 | 17 |
5 | 13 | 1040.80 | 36 | 13.45 | 1111 | 538 | 4.28 / 1152.22 | 5 | 25 |
6 | 13 | 384.76 | 36 | 13.84 | 623 | 310 | 4.59 / 1152.53 | 5 | 27 |
7 | 8 | -0.12 | 450 | 14.12 | 303 | 1925 | 6.51 / 1154.45 | 5 | 22 |
Average= | 6.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.76 | 62 | 14.07 | 372 | 325 | 0.32 / 1141.84 | 5 | 6 |
2 | 7 | 2013.64 | 105 | 10.27 | 1712 | 1846 | 2.17 / 1143.69 | 6 | 5 |
3 | 13 | 1935.40 | 36 | 12.94 | 1711 | 797 | 2.97 / 1144.49 | 5 | 14 |
4 | 13 | 1423.04 | 36 | 13.28 | 1363 | 652 | 3.62 / 1145.14 | 5 | 19 |
5 | 13 | 1099.56 | 36 | 13.43 | 1146 | 554 | 4.17 / 1145.69 | 5 | 25 |
6 | 13 | 362.44 | 36 | 13.88 | 592 | 296 | 4.47 / 1145.99 | 5 | 26 |
7 | 8 | 0.16 | 450 | 14.13 | 307 | 1952 | 6.42 / 1147.94 | 5 | 27 |
Average= | 6.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.08 | 62 | 14.04 | 380 | 331 | 0.33 / 1135.11 | 5 | 5 |
2 | 7 | 2013.04 | 106 | 10.31 | 1713 | 1872 | 2.20 / 1136.98 | 5 | 5 |
3 | 13 | 1927.96 | 36 | 12.94 | 1705 | 794 | 3.00 / 1137.78 | 5 | 13 |
4 | 13 | 1621.96 | 36 | 13.17 | 1513 | 717 | 3.71 / 1138.49 | 5 | 17 |
5 | 13 | 998.32 | 36 | 13.47 | 1076 | 522 | 4.24 / 1139.02 | 5 | 26 |
6 | 13 | 689.00 | 36 | 13.65 | 848 | 417 | 4.65 / 1139.43 | 5 | 29 |
7 | 13 | 3.00 | 36 | 14.20 | 321 | 164 | 4.82 / 1139.60 | 5 | 18 |
8 | 8 | 0.08 | 450 | 14.14 | 302 | 1922 | 6.74 / 1141.52 | 5 | 44 |
Average= | 6.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.00 | 62 | 14.05 | 373 | 325 | 0.32 / 1128.60 | 5 | 5 |
2 | 7 | 2011.80 | 105 | 10.31 | 1707 | 1848 | 2.17 / 1130.45 | 5 | 5 |
3 | 13 | 1930.08 | 36 | 12.93 | 1716 | 799 | 2.97 / 1131.25 | 5 | 13 |
4 | 13 | 1508.56 | 36 | 13.23 | 1428 | 680 | 3.65 / 1131.93 | 5 | 19 |
5 | 13 | 1078.00 | 36 | 13.44 | 1133 | 548 | 4.20 / 1132.48 | 5 | 26 |
6 | 13 | 533.76 | 36 | 13.75 | 730 | 361 | 4.56 / 1132.84 | 5 | 28 |
7 | 8 | 0.00 | 450 | 14.14 | 305 | 1941 | 6.50 / 1134.78 | 5 | 29 |
Average= | 6.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.48 | 62 | 14.03 | 387 | 337 | 0.34 / 1121.88 | 5 | 5 |
2 | 7 | 2003.20 | 105 | 10.32 | 1711 | 1854 | 2.19 / 1123.73 | 5 | 5 |
3 | 13 | 1922.20 | 36 | 12.94 | 1708 | 796 | 2.99 / 1124.53 | 5 | 13 |
4 | 13 | 1719.04 | 36 | 13.12 | 1579 | 746 | 3.73 / 1125.28 | 5 | 15 |
5 | 13 | 1282.36 | 36 | 13.34 | 1272 | 611 | 4.34 / 1125.89 | 5 | 23 |
6 | 13 | 411.24 | 36 | 13.86 | 618 | 308 | 4.65 / 1126.19 | 5 | 26 |
7 | 13 | 2.68 | 36 | 14.20 | 329 | 168 | 4.82 / 1126.36 | 5 | 13 |
8 | 8 | -0.04 | 450 | 14.14 | 301 | 1915 | 6.73 / 1128.28 | 5 | 40 |
Average= | 6.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.04 | 62 | 14.05 | 380 | 331 | 0.33 / 1115.13 | 5 | 6 |
2 | 7 | 2016.12 | 105 | 10.32 | 1722 | 1866 | 2.20 / 1116.99 | 6 | 5 |
3 | 13 | 1931.72 | 36 | 12.94 | 1715 | 799 | 3.00 / 1117.79 | 5 | 13 |
4 | 13 | 1513.16 | 36 | 13.23 | 1447 | 689 | 3.69 / 1118.48 | 5 | 18 |
5 | 13 | 1093.48 | 36 | 13.43 | 1148 | 555 | 4.24 / 1119.04 | 5 | 25 |
6 | 13 | 549.36 | 36 | 13.72 | 757 | 374 | 4.61 / 1119.41 | 5 | 28 |
7 | 13 | 56.16 | 36 | 14.14 | 366 | 186 | 4.80 / 1119.60 | 5 | 17 |
8 | 8 | 0.24 | 450 | 14.14 | 306 | 1947 | 6.75 / 1121.54 | 5 | 24 |
Average= | 6.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.00 | 62 | 14.09 | 379 | 331 | 0.33 / 1108.22 | 5 | 6 |
2 | 7 | 2019.08 | 105 | 10.29 | 1720 | 1858 | 2.19 / 1110.08 | 6 | 5 |
3 | 13 | 1947.64 | 36 | 12.94 | 1714 | 798 | 2.99 / 1110.88 | 5 | 13 |
4 | 13 | 1527.64 | 36 | 13.22 | 1444 | 687 | 3.68 / 1111.57 | 5 | 19 |
5 | 13 | 1115.08 | 36 | 13.41 | 1165 | 562 | 4.24 / 1112.13 | 5 | 24 |
6 | 13 | 691.76 | 36 | 13.64 | 862 | 423 | 4.66 / 1112.55 | 5 | 28 |
7 | 13 | 10.24 | 36 | 14.19 | 330 | 169 | 4.83 / 1112.72 | 5 | 17 |
8 | 13 | 6.56 | 36 | 14.16 | 327 | 167 | 5.00 / 1112.89 | 5 | 19 |
9 | 8 | -0.08 | 450 | 14.14 | 300 | 1909 | 6.90 / 1114.80 | 5 | 33 |
Average= | 6.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.32 | 62 | 14.10 | 371 | 324 | 0.32 / 1101.49 | 5 | 6 |
2 | 7 | 2004.92 | 105 | 10.32 | 1708 | 1851 | 2.18 / 1103.34 | 6 | 5 |
3 | 13 | 1919.88 | 36 | 12.93 | 1702 | 792 | 2.97 / 1104.13 | 5 | 13 |
4 | 13 | 1526.80 | 36 | 13.22 | 1445 | 688 | 3.66 / 1104.82 | 5 | 18 |
5 | 13 | 1094.28 | 36 | 13.41 | 1152 | 556 | 4.21 / 1105.38 | 5 | 23 |
6 | 13 | 656.00 | 36 | 13.65 | 827 | 406 | 4.62 / 1105.78 | 5 | 28 |
7 | 13 | 4.20 | 36 | 14.19 | 329 | 168 | 4.79 / 1105.95 | 5 | 18 |
8 | 8 | -0.12 | 450 | 14.14 | 305 | 1941 | 6.73 / 1107.89 | 5 | 36 |
Average= | 6.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.88 | 62 | 14.08 | 374 | 326 | 0.33 / 1094.95 | 5 | 6 |
2 | 7 | 2003.80 | 105 | 10.35 | 1708 | 1856 | 2.18 / 1096.80 | 6 | 5 |
3 | 13 | 1920.68 | 36 | 12.93 | 1702 | 792 | 2.97 / 1097.60 | 5 | 13 |
4 | 13 | 1723.64 | 36 | 13.12 | 1576 | 744 | 3.72 / 1098.34 | 5 | 15 |
5 | 13 | 1083.76 | 36 | 13.43 | 1143 | 553 | 4.27 / 1098.89 | 5 | 25 |
6 | 13 | 563.72 | 36 | 13.72 | 754 | 372 | 4.64 / 1099.27 | 5 | 27 |
7 | 8 | 0.16 | 450 | 14.16 | 298 | 1899 | 6.54 / 1101.16 | 5 | 45 |
Average= | 6.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.76 | 62 | 14.10 | 379 | 331 | 0.33 / 1088.26 | 5 | 6 |
2 | 7 | 2013.96 | 105 | 10.35 | 1714 | 1863 | 2.19 / 1090.12 | 6 | 5 |
3 | 13 | 1934.08 | 36 | 12.94 | 1710 | 797 | 2.99 / 1090.92 | 5 | 12 |
4 | 13 | 1528.36 | 36 | 13.20 | 1451 | 690 | 3.68 / 1091.61 | 5 | 18 |
5 | 13 | 1116.84 | 36 | 13.40 | 1166 | 562 | 4.24 / 1092.17 | 5 | 24 |
6 | 13 | 596.16 | 36 | 13.70 | 778 | 384 | 4.63 / 1092.55 | 5 | 27 |
7 | 13 | 2.60 | 36 | 14.22 | 318 | 163 | 4.79 / 1092.72 | 5 | 10 |
8 | 8 | -0.12 | 450 | 14.15 | 299 | 1904 | 6.69 / 1094.62 | 5 | 30 |
Average= | 6.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.48 | 62 | 14.10 | 375 | 328 | 0.33 / 1081.59 | 5 | 6 |
2 | 7 | 2006.56 | 105 | 10.34 | 1712 | 1859 | 2.19 / 1083.45 | 6 | 5 |
3 | 13 | 1908.88 | 36 | 12.95 | 1691 | 788 | 2.97 / 1084.24 | 5 | 12 |
4 | 13 | 1704.92 | 36 | 13.13 | 1563 | 739 | 3.71 / 1084.98 | 5 | 15 |
5 | 13 | 1051.52 | 36 | 13.44 | 1124 | 544 | 4.26 / 1085.52 | 5 | 24 |
6 | 13 | 402.28 | 36 | 13.84 | 626 | 312 | 4.57 / 1085.83 | 5 | 25 |
7 | 13 | 91.04 | 36 | 14.12 | 391 | 199 | 4.77 / 1086.03 | 5 | 17 |
8 | 8 | -0.28 | 450 | 14.15 | 298 | 1898 | 6.67 / 1087.93 | 5 | 44 |
Average= | 6.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.44 | 62 | 14.10 | 375 | 328 | 0.33 / 1074.83 | 5 | 6 |
2 | 7 | 2011.40 | 105 | 10.39 | 1708 | 1863 | 2.19 / 1076.70 | 6 | 5 |
3 | 13 | 1921.80 | 36 | 12.94 | 1694 | 789 | 2.98 / 1077.49 | 5 | 12 |
4 | 13 | 1624.48 | 36 | 13.16 | 1512 | 716 | 3.70 / 1078.20 | 5 | 17 |
5 | 13 | 1179.60 | 36 | 13.37 | 1209 | 582 | 4.28 / 1078.78 | 5 | 23 |
6 | 13 | 520.00 | 36 | 13.75 | 716 | 354 | 4.63 / 1079.14 | 5 | 26 |
7 | 13 | 40.04 | 36 | 14.18 | 347 | 177 | 4.81 / 1079.32 | 5 | 16 |
8 | 8 | 0.00 | 450 | 14.14 | 306 | 1947 | 6.76 / 1081.26 | 5 | 36 |
Average= | 6.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.20 | 62 | 14.09 | 375 | 328 | 0.33 / 1068.31 | 5 | 6 |
2 | 7 | 2014.12 | 105 | 10.37 | 1704 | 1855 | 2.18 / 1070.16 | 6 | 5 |
3 | 13 | 1929.80 | 36 | 12.95 | 1696 | 791 | 2.97 / 1070.95 | 5 | 12 |
4 | 13 | 1727.80 | 36 | 13.12 | 1577 | 745 | 3.72 / 1071.70 | 5 | 15 |
5 | 13 | 969.56 | 36 | 13.47 | 1065 | 516 | 4.23 / 1072.21 | 5 | 26 |
6 | 13 | 544.64 | 36 | 13.72 | 745 | 368 | 4.60 / 1072.58 | 5 | 28 |
7 | 8 | 0.08 | 450 | 14.15 | 302 | 1923 | 6.53 / 1074.51 | 5 | 31 |
Average= | 6.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.40 | 62 | 14.10 | 378 | 330 | 0.33 / 1061.63 | 5 | 6 |
2 | 7 | 2014.80 | 106 | 10.40 | 1704 | 1878 | 2.21 / 1063.50 | 6 | 5 |
3 | 13 | 1931.24 | 36 | 12.94 | 1697 | 791 | 3.00 / 1064.29 | 5 | 13 |
4 | 13 | 1732.12 | 36 | 13.12 | 1574 | 743 | 3.74 / 1065.04 | 5 | 15 |
5 | 13 | 1091.28 | 36 | 13.43 | 1140 | 551 | 4.29 / 1065.59 | 5 | 25 |
6 | 13 | 368.40 | 36 | 13.88 | 592 | 296 | 4.59 / 1065.89 | 5 | 23 |
7 | 13 | 14.40 | 36 | 14.20 | 325 | 166 | 4.76 / 1066.05 | 5 | 15 |
8 | 8 | -0.12 | 450 | 14.14 | 303 | 1928 | 6.68 / 1067.98 | 5 | 47 |
Average= | 6.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.84 | 61 | 14.10 | 379 | 326 | 0.33 / 1054.83 | 5 | 6 |
2 | 3 | 1012.72 | 1 | 13.06 | 1086 | 14 | 0.34 / 1054.84 | 5 | 5 |
3 | 7 | 2017.36 | 106 | 10.38 | 1719 | 1891 | 2.23 / 1056.73 | 5 | 5 |
4 | 13 | 1929.88 | 36 | 12.95 | 1699 | 792 | 3.02 / 1057.53 | 5 | 12 |
5 | 13 | 1615.92 | 36 | 13.17 | 1500 | 711 | 3.73 / 1058.24 | 5 | 16 |
6 | 13 | 1181.92 | 36 | 13.37 | 1205 | 580 | 4.31 / 1058.82 | 5 | 23 |
7 | 13 | 616.12 | 36 | 13.68 | 791 | 390 | 4.70 / 1059.21 | 5 | 28 |
8 | 13 | 31.08 | 36 | 14.18 | 340 | 174 | 4.88 / 1059.38 | 5 | 17 |
9 | 8 | -0.08 | 450 | 14.14 | 301 | 1915 | 6.79 / 1061.30 | 5 | 30 |
Average= | 6.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.28 | 61 | 14.12 | 368 | 317 | 0.32 / 1048.09 | 5 | 6 |
2 | 7 | 2005.72 | 105 | 10.41 | 1696 | 1854 | 2.17 / 1049.95 | 6 | 5 |
3 | 13 | 1915.80 | 36 | 12.94 | 1692 | 788 | 2.96 / 1050.74 | 5 | 12 |
4 | 13 | 1412.44 | 36 | 13.27 | 1359 | 649 | 3.61 / 1051.39 | 5 | 19 |
5 | 13 | 1315.44 | 36 | 13.30 | 1291 | 618 | 4.23 / 1052.00 | 5 | 21 |
6 | 13 | 635.08 | 36 | 13.67 | 807 | 397 | 4.62 / 1052.40 | 5 | 28 |
7 | 13 | 34.28 | 36 | 14.18 | 343 | 175 | 4.80 / 1052.58 | 5 | 16 |
8 | 8 | -0.12 | 450 | 14.13 | 303 | 1927 | 6.73 / 1054.50 | 5 | 32 |
Average= | 6.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.76 | 61 | 14.14 | 362 | 312 | 0.31 / 1041.31 | 6 | 6 |
2 | 7 | 2006.40 | 106 | 10.41 | 1703 | 1879 | 2.19 / 1043.19 | 6 | 5 |
3 | 13 | 1920.00 | 36 | 12.93 | 1695 | 789 | 2.98 / 1043.98 | 5 | 13 |
4 | 13 | 1706.44 | 36 | 13.12 | 1559 | 736 | 3.72 / 1044.71 | 5 | 14 |
5 | 13 | 1157.96 | 36 | 13.39 | 1186 | 572 | 4.29 / 1045.29 | 5 | 23 |
6 | 13 | 609.44 | 36 | 13.70 | 779 | 384 | 4.67 / 1045.67 | 5 | 26 |
7 | 13 | 25.88 | 36 | 14.19 | 339 | 173 | 4.85 / 1045.84 | 5 | 16 |
8 | 8 | -0.24 | 450 | 14.13 | 304 | 1933 | 6.78 / 1047.78 | 5 | 31 |
Average= | 6.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.28 | 61 | 14.13 | 368 | 317 | 0.32 / 1034.60 | 6 | 6 |
2 | 7 | 2018.68 | 105 | 10.39 | 1716 | 1872 | 2.19 / 1036.48 | 6 | 5 |
3 | 13 | 1951.60 | 36 | 12.92 | 1718 | 799 | 2.99 / 1037.27 | 5 | 12 |
4 | 13 | 1549.20 | 36 | 13.19 | 1462 | 694 | 3.68 / 1037.97 | 5 | 17 |
5 | 13 | 1121.64 | 36 | 13.40 | 1160 | 560 | 4.24 / 1038.53 | 5 | 23 |
6 | 13 | 571.92 | 36 | 13.71 | 767 | 379 | 4.62 / 1038.91 | 5 | 27 |
7 | 13 | 26.84 | 36 | 14.19 | 344 | 176 | 4.80 / 1039.08 | 5 | 16 |
8 | 8 | -0.08 | 450 | 14.14 | 301 | 1915 | 6.71 / 1041.00 | 5 | 45 |
Average= | 6.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.56 | 61 | 14.14 | 371 | 320 | 0.32 / 1028.04 | 5 | 6 |
2 | 7 | 2008.80 | 105 | 10.38 | 1716 | 1870 | 2.19 / 1029.91 | 6 | 5 |
3 | 13 | 1933.80 | 36 | 12.92 | 1707 | 794 | 2.98 / 1030.71 | 5 | 12 |
4 | 13 | 1519.04 | 36 | 13.21 | 1438 | 684 | 3.67 / 1031.39 | 5 | 18 |
5 | 13 | 1093.40 | 36 | 13.41 | 1143 | 552 | 4.22 / 1031.94 | 5 | 23 |
6 | 13 | 351.00 | 36 | 13.89 | 591 | 296 | 4.52 / 1032.24 | 5 | 22 |
7 | 13 | 10.08 | 36 | 14.21 | 322 | 165 | 4.68 / 1032.40 | 5 | 15 |
8 | 8 | -0.04 | 450 | 14.14 | 296 | 1883 | 6.56 / 1034.29 | 5 | 35 |
Average= | 6.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.68 | 61 | 14.14 | 371 | 320 | 0.32 / 1022.17 | 5 | 5 |
2 | 7 | 1457.32 | 105 | 10.96 | 1352 | 1556 | 1.88 / 1023.72 | 5 | 6 |
3 | 13 | 1420.24 | 36 | 13.13 | 1368 | 647 | 2.52 / 1024.37 | 5 | 16 |
4 | 13 | 1152.44 | 36 | 13.35 | 1197 | 575 | 3.10 / 1024.94 | 5 | 22 |
5 | 13 | 957.96 | 36 | 13.46 | 1055 | 511 | 3.61 / 1025.46 | 5 | 25 |
6 | 13 | 399.96 | 36 | 13.83 | 639 | 318 | 3.93 / 1025.77 | 5 | 24 |
7 | 8 | -0.08 | 450 | 14.11 | 307 | 1949 | 5.88 / 1027.72 | 5 | 28 |
Average= | 6.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.56 | 61 | 14.14 | 363 | 313 | 0.31 / 1015.72 | 5 | 6 |
2 | 7 | 2004.48 | 106 | 10.46 | 1708 | 1894 | 2.21 / 1017.61 | 5 | 5 |
3 | 13 | 1918.88 | 36 | 12.94 | 1703 | 793 | 3.00 / 1018.41 | 5 | 12 |
4 | 13 | 1607.60 | 36 | 13.18 | 1497 | 710 | 3.71 / 1019.12 | 5 | 15 |
5 | 13 | 972.12 | 36 | 13.47 | 1061 | 515 | 4.22 / 1019.63 | 5 | 24 |
6 | 13 | 349.00 | 36 | 13.88 | 597 | 298 | 4.52 / 1019.93 | 5 | 23 |
7 | 8 | -0.08 | 450 | 14.14 | 301 | 1915 | 6.44 / 1021.85 | 5 | 24 |
Average= | 6.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.12 | 61 | 14.15 | 365 | 315 | 0.32 / 1009.04 | 5 | 6 |
2 | 7 | 2015.20 | 105 | 10.45 | 1712 | 1878 | 2.19 / 1010.92 | 6 | 5 |
3 | 13 | 1937.80 | 36 | 12.93 | 1707 | 795 | 2.99 / 1011.71 | 5 | 11 |
4 | 13 | 1528.40 | 36 | 13.20 | 1443 | 686 | 3.67 / 1012.40 | 5 | 16 |
5 | 13 | 1095.04 | 36 | 13.41 | 1146 | 553 | 4.23 / 1012.95 | 5 | 22 |
6 | 13 | 555.80 | 36 | 13.73 | 748 | 370 | 4.60 / 1013.32 | 5 | 26 |
7 | 13 | 20.48 | 36 | 14.21 | 332 | 170 | 4.77 / 1013.49 | 5 | 15 |
8 | 8 | -0.12 | 450 | 14.14 | 301 | 1915 | 6.68 / 1015.41 | 5 | 34 |
Average= | 6.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.24 | 61 | 14.16 | 362 | 313 | 0.31 / 1002.30 | 5 | 6 |
2 | 7 | 2008.72 | 105 | 10.47 | 1710 | 1880 | 2.19 / 1004.18 | 6 | 5 |
3 | 13 | 1920.36 | 36 | 12.93 | 1698 | 790 | 2.98 / 1004.97 | 5 | 11 |
4 | 13 | 1616.32 | 36 | 13.17 | 1491 | 707 | 3.69 / 1005.68 | 5 | 15 |
5 | 13 | 992.44 | 36 | 13.47 | 1069 | 518 | 4.21 / 1006.20 | 5 | 23 |
6 | 13 | 778.68 | 36 | 13.59 | 916 | 448 | 4.66 / 1006.64 | 5 | 26 |
7 | 13 | 39.12 | 36 | 14.19 | 351 | 179 | 4.84 / 1006.82 | 5 | 15 |
8 | 8 | -0.16 | 450 | 14.14 | 299 | 1903 | 6.74 / 1008.73 | 5 | 31 |
Average= | 6.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.32 | 61 | 14.13 | 373 | 321 | 0.32 / 995.50 | 5 | 6 |
2 | 7 | 2006.76 | 105 | 10.48 | 1708 | 1879 | 2.20 / 997.38 | 6 | 5 |
3 | 13 | 1920.44 | 36 | 12.94 | 1690 | 787 | 2.99 / 998.17 | 5 | 10 |
4 | 13 | 1731.00 | 36 | 13.10 | 1573 | 742 | 3.73 / 998.91 | 5 | 13 |
5 | 13 | 1189.08 | 36 | 13.37 | 1217 | 586 | 4.32 / 999.49 | 5 | 21 |
6 | 13 | 648.04 | 36 | 13.67 | 818 | 403 | 4.72 / 999.90 | 5 | 26 |
7 | 13 | 36.72 | 36 | 14.18 | 347 | 177 | 4.90 / 1000.07 | 5 | 16 |
8 | 8 | -0.16 | 450 | 14.13 | 301 | 1914 | 6.81 / 1001.99 | 5 | 34 |
Average= | 6.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.56 | 61 | 14.14 | 367 | 317 | 0.32 / 988.77 | 5 | 5 |
2 | 7 | 2004.80 | 105 | 10.52 | 1702 | 1880 | 2.20 / 990.65 | 5 | 5 |
3 | 13 | 1914.84 | 36 | 12.92 | 1698 | 790 | 2.99 / 991.44 | 5 | 11 |
4 | 13 | 1603.16 | 36 | 13.16 | 1507 | 714 | 3.70 / 992.16 | 5 | 16 |
5 | 13 | 1064.52 | 36 | 13.42 | 1131 | 546 | 4.25 / 992.70 | 5 | 22 |
6 | 13 | 535.08 | 36 | 13.74 | 738 | 365 | 4.61 / 993.07 | 5 | 26 |
7 | 13 | 6.28 | 36 | 14.21 | 332 | 170 | 4.78 / 993.24 | 5 | 16 |
8 | 8 | -0.28 | 450 | 14.10 | 306 | 1942 | 6.72 / 995.18 | 5 | 37 |
Average= | 6.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.44 | 61 | 14.12 | 374 | 322 | 0.32 / 982.23 | 5 | 5 |
2 | 7 | 2015.12 | 106 | 10.52 | 1712 | 1909 | 2.23 / 984.14 | 5 | 5 |
3 | 13 | 1931.80 | 36 | 12.92 | 1700 | 791 | 3.02 / 984.93 | 5 | 11 |
4 | 13 | 1622.08 | 36 | 13.16 | 1502 | 712 | 3.73 / 985.64 | 5 | 16 |
5 | 13 | 1089.28 | 36 | 13.41 | 1151 | 556 | 4.29 / 986.20 | 5 | 22 |
6 | 13 | 448.76 | 36 | 13.80 | 665 | 330 | 4.62 / 986.53 | 5 | 24 |
7 | 8 | 0.00 | 450 | 14.12 | 303 | 1925 | 6.54 / 988.46 | 5 | 31 |
Average= | 6.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.24 | 61 | 14.09 | 382 | 328 | 0.33 / 975.78 | 5 | 5 |
2 | 7 | 2005.76 | 105 | 10.54 | 1705 | 1887 | 2.22 / 977.67 | 5 | 5 |
3 | 13 | 1924.00 | 36 | 12.92 | 1704 | 793 | 3.01 / 978.46 | 5 | 11 |
4 | 13 | 1526.00 | 36 | 13.19 | 1451 | 689 | 3.70 / 979.15 | 5 | 15 |
5 | 13 | 990.88 | 36 | 13.46 | 1078 | 522 | 4.22 / 979.67 | 5 | 23 |
6 | 13 | 459.08 | 36 | 13.79 | 685 | 340 | 4.56 / 980.01 | 5 | 25 |
7 | 8 | -0.12 | 450 | 14.11 | 299 | 1899 | 6.46 / 981.91 | 5 | 31 |
Average= | 6.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.72 | 61 | 14.09 | 382 | 328 | 0.33 / 969.25 | 5 | 5 |
2 | 7 | 2014.68 | 106 | 10.52 | 1722 | 1920 | 2.25 / 971.17 | 5 | 5 |
3 | 13 | 1943.32 | 36 | 12.93 | 1711 | 796 | 3.04 / 971.97 | 5 | 11 |
4 | 13 | 1530.08 | 36 | 13.20 | 1450 | 689 | 3.73 / 972.65 | 5 | 15 |
5 | 13 | 1091.76 | 36 | 13.41 | 1147 | 554 | 4.29 / 973.21 | 5 | 22 |
6 | 13 | 448.24 | 36 | 13.80 | 671 | 333 | 4.62 / 973.54 | 5 | 25 |
7 | 8 | 0.12 | 450 | 14.11 | 301 | 1911 | 6.53 / 975.45 | 5 | 18 |
Average= | 6.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.20 | 61 | 14.07 | 380 | 326 | 0.33 / 962.77 | 5 | 5 |
2 | 7 | 2004.08 | 106 | 10.55 | 1699 | 1900 | 2.23 / 964.67 | 5 | 5 |
3 | 13 | 1907.48 | 36 | 12.94 | 1689 | 787 | 3.01 / 965.45 | 5 | 11 |
4 | 13 | 1490.76 | 36 | 13.23 | 1405 | 669 | 3.68 / 966.12 | 5 | 16 |
5 | 13 | 1067.08 | 36 | 13.43 | 1123 | 543 | 4.23 / 966.66 | 5 | 22 |
6 | 13 | 410.92 | 36 | 13.84 | 634 | 316 | 4.54 / 966.98 | 5 | 25 |
7 | 8 | 0.08 | 450 | 14.09 | 306 | 1940 | 6.48 / 968.92 | 5 | 29 |
Average= | 6.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.16 | 61 | 14.09 | 376 | 323 | 0.32 / 955.82 | 5 | 5 |
2 | 7 | 2013.32 | 105 | 10.57 | 1714 | 1902 | 2.23 / 957.73 | 5 | 5 |
3 | 13 | 1925.36 | 36 | 12.92 | 1716 | 798 | 3.02 / 958.53 | 5 | 11 |
4 | 13 | 1609.00 | 36 | 13.16 | 1504 | 713 | 3.74 / 959.24 | 5 | 14 |
5 | 13 | 1068.28 | 36 | 13.42 | 1131 | 546 | 4.28 / 959.78 | 5 | 21 |
6 | 13 | 756.00 | 36 | 13.60 | 907 | 444 | 4.73 / 960.23 | 5 | 25 |
7 | 13 | 21.16 | 36 | 14.20 | 333 | 170 | 4.90 / 960.40 | 5 | 15 |
8 | 13 | 8.16 | 36 | 14.14 | 329 | 167 | 5.06 / 960.57 | 5 | 16 |
9 | 8 | -0.16 | 450 | 14.11 | 295 | 1873 | 6.94 / 962.44 | 5 | 33 |
Average= | 6.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.00 | 61 | 14.09 | 371 | 319 | 0.32 / 949.27 | 5 | 5 |
2 | 7 | 2007.12 | 105 | 10.55 | 1708 | 1892 | 2.21 / 951.16 | 5 | 5 |
3 | 13 | 1928.76 | 36 | 12.93 | 1692 | 788 | 3.00 / 951.95 | 5 | 10 |
4 | 13 | 1619.00 | 36 | 13.16 | 1512 | 716 | 3.71 / 952.66 | 5 | 14 |
5 | 13 | 1080.72 | 36 | 13.43 | 1132 | 547 | 4.26 / 953.21 | 5 | 20 |
6 | 13 | 548.16 | 36 | 13.72 | 759 | 375 | 4.64 / 953.59 | 5 | 24 |
7 | 8 | -0.04 | 450 | 14.10 | 302 | 1916 | 6.55 / 955.50 | 5 | 25 |
Average= | 6.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.84 | 61 | 14.11 | 377 | 324 | 0.32 / 942.59 | 5 | 5 |
2 | 7 | 2005.80 | 106 | 10.58 | 1705 | 1912 | 2.24 / 944.50 | 5 | 5 |
3 | 13 | 1932.40 | 36 | 12.91 | 1713 | 796 | 3.03 / 945.30 | 5 | 10 |
4 | 13 | 1733.40 | 36 | 13.09 | 1589 | 749 | 3.78 / 946.05 | 5 | 13 |
5 | 13 | 1286.48 | 36 | 13.32 | 1274 | 611 | 4.39 / 946.66 | 5 | 18 |
6 | 13 | 598.84 | 36 | 13.68 | 792 | 390 | 4.78 / 947.05 | 5 | 24 |
7 | 8 | -0.12 | 450 | 14.09 | 300 | 1902 | 6.68 / 948.95 | 5 | 26 |
Average= | 6.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.64 | 61 | 14.07 | 384 | 330 | 0.33 / 935.97 | 5 | 5 |
2 | 7 | 2012.00 | 106 | 10.58 | 1704 | 1911 | 2.24 / 937.88 | 5 | 5 |
3 | 13 | 1921.92 | 36 | 12.93 | 1684 | 784 | 3.02 / 938.67 | 5 | 10 |
4 | 13 | 1714.48 | 36 | 13.11 | 1565 | 739 | 3.76 / 939.41 | 5 | 12 |
5 | 13 | 1269.20 | 36 | 13.33 | 1270 | 609 | 4.37 / 940.02 | 5 | 18 |
6 | 13 | 495.40 | 36 | 13.76 | 709 | 351 | 4.72 / 940.37 | 5 | 23 |
7 | 8 | 0.04 | 450 | 14.10 | 299 | 1897 | 6.62 / 942.26 | 5 | 14 |
Average= | 6.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.68 | 61 | 14.10 | 373 | 321 | 0.32 / 929.43 | 5 | 5 |
2 | 7 | 2006.44 | 106 | 10.58 | 1709 | 1917 | 2.24 / 931.35 | 5 | 5 |
3 | 13 | 1923.44 | 36 | 12.91 | 1708 | 794 | 3.03 / 932.14 | 5 | 10 |
4 | 13 | 1510.04 | 36 | 13.20 | 1444 | 686 | 3.72 / 932.83 | 5 | 14 |
5 | 13 | 1078.44 | 36 | 13.41 | 1145 | 553 | 4.27 / 933.38 | 5 | 20 |
6 | 13 | 451.72 | 36 | 13.80 | 675 | 335 | 4.61 / 933.72 | 5 | 24 |
7 | 8 | 0.16 | 450 | 14.08 | 304 | 1926 | 6.53 / 935.64 | 5 | 23 |
Average= | 6.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.08 | 61 | 14.07 | 387 | 332 | 0.33 / 922.78 | 5 | 5 |
2 | 7 | 2005.20 | 105 | 10.64 | 1706 | 1906 | 2.24 / 924.69 | 5 | 5 |
3 | 13 | 1915.24 | 36 | 12.92 | 1684 | 783 | 3.02 / 925.47 | 5 | 10 |
4 | 13 | 1500.40 | 36 | 13.21 | 1413 | 672 | 3.69 / 926.14 | 5 | 15 |
5 | 13 | 1059.00 | 36 | 13.44 | 1109 | 537 | 4.23 / 926.68 | 5 | 21 |
6 | 13 | 489.48 | 36 | 13.77 | 689 | 342 | 4.57 / 927.02 | 5 | 24 |
7 | 13 | 30.36 | 36 | 14.19 | 344 | 176 | 4.75 / 927.20 | 5 | 16 |
8 | 8 | -0.04 | 450 | 14.08 | 302 | 1913 | 6.66 / 929.11 | 5 | 21 |
Average= | 6.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.24 | 61 | 14.06 | 392 | 336 | 0.34 / 916.38 | 5 | 5 |
2 | 7 | 2007.88 | 106 | 10.63 | 1703 | 1919 | 2.26 / 918.30 | 5 | 5 |
3 | 13 | 1919.28 | 36 | 12.91 | 1693 | 787 | 3.04 / 919.09 | 5 | 10 |
4 | 13 | 1505.20 | 36 | 13.21 | 1419 | 675 | 3.72 / 919.76 | 5 | 15 |
5 | 13 | 984.56 | 36 | 13.47 | 1058 | 513 | 4.23 / 920.28 | 5 | 22 |
6 | 13 | 252.04 | 36 | 14.01 | 501 | 253 | 4.48 / 920.53 | 5 | 19 |
7 | 8 | -0.04 | 450 | 14.09 | 303 | 1921 | 6.40 / 922.45 | 5 | 19 |
Average= | 6.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.04 | 61 | 14.10 | 375 | 323 | 0.32 / 909.67 | 5 | 5 |
2 | 7 | 2011.96 | 105 | 10.66 | 1705 | 1908 | 2.23 / 911.58 | 5 | 5 |
3 | 13 | 1925.48 | 36 | 12.90 | 1692 | 786 | 3.02 / 912.36 | 5 | 10 |
4 | 13 | 1615.64 | 36 | 13.16 | 1490 | 706 | 3.72 / 913.07 | 5 | 13 |
5 | 13 | 1088.28 | 36 | 13.42 | 1130 | 546 | 4.27 / 913.61 | 5 | 20 |
6 | 13 | 540.92 | 36 | 13.74 | 728 | 360 | 4.63 / 913.97 | 5 | 25 |
7 | 13 | 22.12 | 36 | 14.19 | 342 | 175 | 4.80 / 914.15 | 5 | 16 |
8 | 8 | 0.12 | 450 | 14.07 | 300 | 1899 | 6.70 / 916.05 | 5 | 31 |
Average= | 6.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.28 | 61 | 14.06 | 382 | 328 | 0.33 / 903.26 | 5 | 5 |
2 | 7 | 2005.04 | 105 | 10.72 | 1693 | 1906 | 2.23 / 905.16 | 5 | 5 |
3 | 13 | 1918.00 | 36 | 12.90 | 1693 | 786 | 3.02 / 905.95 | 5 | 10 |
4 | 13 | 1415.72 | 36 | 13.24 | 1364 | 650 | 3.67 / 906.60 | 5 | 15 |
5 | 13 | 995.76 | 36 | 13.46 | 1084 | 525 | 4.19 / 907.13 | 5 | 21 |
6 | 13 | 463.60 | 36 | 13.80 | 679 | 337 | 4.53 / 907.46 | 5 | 24 |
7 | 8 | 0.16 | 450 | 14.08 | 297 | 1882 | 6.41 / 909.34 | 5 | 24 |
Average= | 6.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.96 | 60 | 14.09 | 382 | 323 | 0.32 / 896.84 | 5 | 5 |
2 | 7 | 2012.32 | 106 | 10.73 | 1707 | 1942 | 2.26 / 898.78 | 5 | 5 |
3 | 13 | 1924.68 | 36 | 12.90 | 1698 | 789 | 3.05 / 899.57 | 5 | 10 |
4 | 13 | 1508.84 | 36 | 13.20 | 1430 | 680 | 3.73 / 900.25 | 5 | 14 |
5 | 13 | 985.96 | 36 | 13.46 | 1075 | 521 | 4.25 / 900.77 | 5 | 21 |
6 | 13 | 248.88 | 36 | 13.98 | 514 | 259 | 4.51 / 901.03 | 5 | 20 |
7 | 8 | 0.16 | 450 | 14.08 | 300 | 1901 | 6.41 / 902.93 | 5 | 22 |
Average= | 6.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.16 | 60 | 14.12 | 371 | 314 | 0.31 / 890.38 | 5 | 5 |
2 | 7 | 2005.12 | 105 | 10.76 | 1693 | 1913 | 2.23 / 892.30 | 5 | 5 |
3 | 13 | 1916.24 | 36 | 12.90 | 1682 | 781 | 3.01 / 893.08 | 5 | 10 |
4 | 13 | 1499.20 | 36 | 13.20 | 1416 | 673 | 3.68 / 893.75 | 5 | 15 |
5 | 13 | 1080.20 | 36 | 13.42 | 1133 | 547 | 4.23 / 894.30 | 5 | 20 |
6 | 13 | 413.68 | 36 | 13.83 | 633 | 315 | 4.54 / 894.61 | 5 | 24 |
7 | 8 | 0.16 | 450 | 14.06 | 301 | 1904 | 6.45 / 896.52 | 5 | 25 |
Average= | 6.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.52 | 60 | 14.11 | 382 | 323 | 0.32 / 883.89 | 5 | 5 |
2 | 7 | 2012.48 | 106 | 10.77 | 1699 | 1940 | 2.26 / 885.83 | 5 | 5 |
3 | 13 | 1921.60 | 36 | 12.91 | 1693 | 787 | 3.05 / 886.61 | 5 | 10 |
4 | 13 | 1619.96 | 36 | 13.13 | 1509 | 713 | 3.76 / 887.33 | 5 | 13 |
5 | 13 | 982.28 | 36 | 13.46 | 1067 | 517 | 4.28 / 887.84 | 5 | 21 |
6 | 13 | 440.60 | 36 | 13.81 | 667 | 332 | 4.61 / 888.17 | 5 | 24 |
7 | 8 | 0.08 | 450 | 14.08 | 299 | 1894 | 6.51 / 890.07 | 5 | 22 |
Average= | 6.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.64 | 60 | 14.10 | 383 | 324 | 0.32 / 877.05 | 5 | 5 |
2 | 7 | 2013.08 | 105 | 10.78 | 1714 | 1940 | 2.26 / 879.00 | 5 | 5 |
3 | 13 | 1925.48 | 36 | 12.89 | 1700 | 789 | 3.05 / 879.78 | 5 | 10 |
4 | 13 | 1506.68 | 36 | 13.18 | 1427 | 677 | 3.73 / 880.46 | 5 | 14 |
5 | 13 | 1083.40 | 36 | 13.42 | 1125 | 544 | 4.27 / 881.00 | 5 | 20 |
6 | 13 | 421.60 | 36 | 13.83 | 651 | 324 | 4.60 / 881.33 | 5 | 23 |
7 | 13 | 20.36 | 36 | 14.20 | 336 | 172 | 4.77 / 881.50 | 5 | 16 |
8 | 13 | 9.64 | 36 | 14.12 | 329 | 167 | 4.94 / 881.67 | 5 | 16 |
9 | 8 | 0.12 | 450 | 14.04 | 300 | 1895 | 6.83 / 883.56 | 5 | 29 |
Average= | 6.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.48 | 60 | 14.10 | 372 | 315 | 0.31 / 870.36 | 5 | 5 |
2 | 7 | 2017.44 | 105 | 10.83 | 1709 | 1943 | 2.26 / 872.31 | 5 | 5 |
3 | 13 | 1938.44 | 36 | 12.90 | 1705 | 792 | 3.05 / 873.10 | 5 | 10 |
4 | 13 | 1608.68 | 36 | 13.13 | 1496 | 707 | 3.76 / 873.80 | 5 | 13 |
5 | 13 | 1057.48 | 36 | 13.43 | 1111 | 537 | 4.29 / 874.34 | 5 | 21 |
6 | 13 | 416.72 | 36 | 13.83 | 651 | 324 | 4.62 / 874.67 | 5 | 21 |
7 | 13 | 16.32 | 36 | 14.22 | 331 | 169 | 4.79 / 874.84 | 5 | 17 |
8 | 8 | -0.12 | 450 | 14.04 | 300 | 1895 | 6.68 / 876.73 | 5 | 27 |
Average= | 6.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.24 | 60 | 14.15 | 369 | 313 | 0.31 / 863.70 | 5 | 5 |
2 | 7 | 2004.20 | 105 | 10.87 | 1698 | 1938 | 2.25 / 865.64 | 5 | 5 |
3 | 13 | 1909.52 | 36 | 12.90 | 1676 | 778 | 3.03 / 866.42 | 5 | 10 |
4 | 13 | 1591.28 | 36 | 13.16 | 1469 | 696 | 3.73 / 867.11 | 5 | 15 |
5 | 13 | 951.40 | 36 | 13.47 | 1043 | 506 | 4.23 / 867.62 | 5 | 22 |
6 | 13 | 520.48 | 36 | 13.74 | 732 | 362 | 4.59 / 867.98 | 5 | 24 |
7 | 13 | 15.56 | 36 | 14.20 | 332 | 170 | 4.76 / 868.15 | 5 | 17 |
8 | 8 | -0.20 | 450 | 14.04 | 300 | 1895 | 6.66 / 870.05 | 5 | 28 |
Average= | 6.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.36 | 60 | 14.16 | 368 | 313 | 0.31 / 857.18 | 5 | 6 |
2 | 7 | 2008.72 | 105 | 10.90 | 1704 | 1950 | 2.26 / 859.13 | 6 | 5 |
3 | 13 | 1918.16 | 36 | 12.89 | 1687 | 783 | 3.05 / 859.92 | 5 | 10 |
4 | 13 | 1717.04 | 36 | 13.08 | 1568 | 738 | 3.78 / 860.65 | 5 | 13 |
5 | 13 | 1043.40 | 36 | 13.42 | 1117 | 540 | 4.32 / 861.19 | 5 | 21 |
6 | 13 | 395.12 | 36 | 13.85 | 628 | 313 | 4.64 / 861.51 | 5 | 22 |
7 | 8 | 0.20 | 450 | 14.08 | 297 | 1882 | 6.52 / 863.39 | 5 | 36 |
Average= | 6.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.24 | 60 | 14.17 | 365 | 310 | 0.31 / 850.37 | 5 | 5 |
2 | 7 | 2005.60 | 106 | 10.93 | 1702 | 1972 | 2.28 / 852.34 | 5 | 5 |
3 | 13 | 1921.44 | 36 | 12.88 | 1693 | 785 | 3.07 / 853.13 | 5 | 10 |
4 | 13 | 1823.36 | 36 | 13.01 | 1629 | 763 | 3.83 / 853.89 | 5 | 11 |
5 | 13 | 1118.04 | 36 | 13.38 | 1163 | 560 | 4.39 / 854.45 | 5 | 20 |
6 | 13 | 560.28 | 36 | 13.72 | 752 | 371 | 4.76 / 854.82 | 5 | 24 |
7 | 13 | 17.84 | 36 | 14.22 | 333 | 170 | 4.93 / 854.99 | 5 | 13 |
8 | 8 | -0.24 | 450 | 14.10 | 296 | 1878 | 6.81 / 856.87 | 5 | 21 |
Average= | 6.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.40 | 60 | 14.19 | 364 | 310 | 0.31 / 843.93 | 5 | 6 |
2 | 7 | 2006.40 | 105 | 10.99 | 1712 | 1976 | 2.29 / 845.91 | 6 | 5 |
3 | 13 | 1916.88 | 36 | 12.89 | 1679 | 779 | 3.06 / 846.69 | 5 | 10 |
4 | 13 | 1492.76 | 36 | 13.19 | 1413 | 671 | 3.74 / 847.36 | 5 | 15 |
5 | 13 | 1165.96 | 36 | 13.37 | 1191 | 573 | 4.31 / 847.93 | 5 | 19 |
6 | 13 | 296.64 | 36 | 13.96 | 541 | 272 | 4.58 / 848.20 | 5 | 18 |
7 | 8 | -0.08 | 450 | 14.10 | 293 | 1859 | 6.44 / 850.06 | 5 | 18 |
Average= | 6.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.72 | 60 | 14.19 | 368 | 313 | 0.31 / 837.08 | 5 | 6 |
2 | 7 | 2007.04 | 105 | 11.00 | 1710 | 1975 | 2.29 / 839.05 | 6 | 5 |
3 | 13 | 1922.88 | 36 | 12.86 | 1691 | 783 | 3.07 / 839.84 | 5 | 10 |
4 | 13 | 1717.72 | 36 | 13.06 | 1579 | 742 | 3.81 / 840.58 | 5 | 12 |
5 | 13 | 1251.96 | 36 | 13.32 | 1248 | 598 | 4.41 / 841.18 | 5 | 18 |
6 | 13 | 584.24 | 36 | 13.69 | 776 | 382 | 4.79 / 841.56 | 5 | 24 |
7 | 13 | 50.56 | 36 | 14.18 | 363 | 185 | 4.98 / 841.75 | 5 | 14 |
8 | 8 | 0.00 | 450 | 14.07 | 296 | 1874 | 6.85 / 843.62 | 5 | 25 |
Average= | 6.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.24 | 60 | 14.19 | 362 | 308 | 0.31 / 830.38 | 5 | 6 |
2 | 7 | 2007.68 | 105 | 11.03 | 1711 | 1982 | 2.29 / 832.36 | 6 | 5 |
3 | 13 | 1911.44 | 36 | 12.85 | 1690 | 782 | 3.07 / 833.14 | 5 | 10 |
4 | 13 | 1597.88 | 36 | 13.12 | 1487 | 702 | 3.77 / 833.85 | 5 | 13 |
5 | 13 | 1044.16 | 36 | 13.41 | 1102 | 532 | 4.31 / 834.38 | 5 | 21 |
6 | 13 | 512.12 | 36 | 13.75 | 711 | 352 | 4.66 / 834.73 | 5 | 24 |
7 | 13 | 17.96 | 36 | 14.22 | 329 | 168 | 4.83 / 834.90 | 5 | 13 |
8 | 8 | -0.12 | 450 | 14.08 | 295 | 1869 | 6.70 / 836.77 | 5 | 24 |
Average= | 6.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.84 | 60 | 14.22 | 354 | 302 | 0.30 / 823.65 | 6 | 6 |
2 | 3 | 1010.72 | 1 | 12.02 | 1094 | 13 | 0.32 / 823.66 | 5 | 5 |
3 | 7 | 2018.28 | 105 | 11.10 | 1708 | 1991 | 2.31 / 825.65 | 5 | 5 |
4 | 13 | 1934.84 | 36 | 12.85 | 1702 | 787 | 3.09 / 826.44 | 5 | 9 |
5 | 13 | 1527.20 | 36 | 13.16 | 1437 | 681 | 3.77 / 827.12 | 5 | 13 |
6 | 13 | 999.36 | 36 | 13.43 | 1072 | 518 | 4.29 / 827.64 | 5 | 20 |
7 | 13 | 665.40 | 36 | 13.65 | 819 | 402 | 4.69 / 828.04 | 5 | 24 |
8 | 13 | 37.80 | 36 | 14.22 | 339 | 174 | 4.87 / 828.21 | 5 | 12 |
9 | 8 | -0.04 | 450 | 14.10 | 293 | 1859 | 6.73 / 830.07 | 5 | 34 |
Average= | 6.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.64 | 60 | 14.20 | 368 | 314 | 0.31 / 817.07 | 6 | 6 |
2 | 7 | 2008.12 | 105 | 11.12 | 1702 | 1987 | 2.30 / 819.06 | 6 | 5 |
3 | 13 | 1933.60 | 36 | 12.85 | 1694 | 784 | 3.08 / 819.84 | 5 | 9 |
4 | 13 | 1413.16 | 36 | 13.20 | 1360 | 646 | 3.73 / 820.49 | 5 | 15 |
5 | 13 | 1214.92 | 36 | 13.33 | 1219 | 585 | 4.32 / 821.07 | 5 | 18 |
6 | 13 | 314.72 | 36 | 13.95 | 547 | 275 | 4.59 / 821.35 | 5 | 18 |
7 | 13 | 44.56 | 36 | 14.23 | 335 | 172 | 4.76 / 821.52 | 5 | 11 |
8 | 8 | -0.04 | 450 | 14.14 | 287 | 1826 | 6.59 / 823.34 | 5 | 26 |
Average= | 6.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.60 | 60 | 14.23 | 352 | 301 | 0.30 / 810.39 | 6 | 6 |
2 | 7 | 2005.56 | 106 | 11.15 | 1704 | 2014 | 2.31 / 812.40 | 6 | 5 |
3 | 13 | 1914.52 | 36 | 12.85 | 1687 | 780 | 3.09 / 813.18 | 5 | 10 |
4 | 13 | 1609.40 | 36 | 13.11 | 1490 | 703 | 3.80 / 813.89 | 5 | 13 |
5 | 13 | 1162.12 | 36 | 13.35 | 1184 | 569 | 4.37 / 814.46 | 5 | 19 |
6 | 13 | 391.64 | 36 | 13.87 | 606 | 303 | 4.67 / 814.76 | 5 | 20 |
7 | 13 | 14.32 | 36 | 14.25 | 319 | 164 | 4.83 / 814.92 | 5 | 11 |
8 | 8 | -0.04 | 450 | 14.10 | 289 | 1834 | 6.67 / 816.76 | 5 | 27 |
Average= | 6.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.00 | 60 | 14.21 | 358 | 305 | 0.31 / 803.79 | 6 | 6 |
2 | 7 | 2009.44 | 105 | 11.20 | 1707 | 2007 | 2.31 / 805.80 | 6 | 5 |
3 | 13 | 1920.36 | 36 | 12.85 | 1677 | 776 | 3.09 / 806.57 | 5 | 10 |
4 | 13 | 1604.04 | 36 | 13.11 | 1481 | 699 | 3.79 / 807.27 | 5 | 14 |
5 | 13 | 1035.16 | 36 | 13.41 | 1085 | 524 | 4.31 / 807.79 | 5 | 21 |
6 | 13 | 375.04 | 36 | 13.88 | 600 | 300 | 4.61 / 808.09 | 5 | 20 |
7 | 13 | 14.04 | 36 | 14.26 | 314 | 161 | 4.77 / 808.25 | 5 | 11 |
8 | 8 | -0.20 | 450 | 14.10 | 289 | 1834 | 6.61 / 810.09 | 5 | 33 |
Average= | 6.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.64 | 60 | 14.22 | 354 | 302 | 0.30 / 797.29 | 6 | 6 |
2 | 7 | 2004.80 | 105 | 11.23 | 1704 | 2009 | 2.31 / 799.30 | 6 | 5 |
3 | 13 | 1914.76 | 36 | 12.87 | 1668 | 773 | 3.08 / 800.07 | 5 | 9 |
4 | 13 | 1405.36 | 36 | 13.20 | 1347 | 640 | 3.72 / 800.71 | 5 | 15 |
5 | 13 | 874.20 | 36 | 13.50 | 977 | 475 | 4.20 / 801.19 | 5 | 21 |
6 | 13 | 356.96 | 36 | 13.89 | 588 | 294 | 4.49 / 801.48 | 5 | 20 |
7 | 13 | 26.72 | 36 | 14.23 | 327 | 168 | 4.66 / 801.65 | 5 | 11 |
8 | 8 | 0.00 | 450 | 14.10 | 289 | 1834 | 6.49 / 803.48 | 5 | 30 |
Average= | 6.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.72 | 60 | 14.24 | 359 | 307 | 0.31 / 790.62 | 5 | 6 |
2 | 7 | 2009.36 | 105 | 11.28 | 1710 | 2025 | 2.33 / 792.65 | 6 | 5 |
3 | 13 | 1915.48 | 36 | 12.86 | 1678 | 777 | 3.11 / 793.43 | 5 | 9 |
4 | 13 | 1502.52 | 36 | 13.14 | 1420 | 672 | 3.78 / 794.10 | 5 | 14 |
5 | 13 | 1171.32 | 36 | 13.33 | 1189 | 571 | 4.35 / 794.67 | 5 | 19 |
6 | 13 | 380.40 | 36 | 13.86 | 611 | 305 | 4.66 / 794.97 | 5 | 21 |
7 | 13 | 29.32 | 36 | 14.22 | 334 | 171 | 4.83 / 795.14 | 5 | 12 |
8 | 8 | -0.28 | 450 | 14.09 | 291 | 1845 | 6.67 / 796.99 | 5 | 29 |
Average= | 6.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.24 | 60 | 14.24 | 354 | 302 | 0.30 / 784.04 | 5 | 6 |
2 | 7 | 2007.52 | 105 | 11.31 | 1713 | 2034 | 2.34 / 786.07 | 6 | 6 |
3 | 13 | 1922.36 | 36 | 12.84 | 1691 | 782 | 3.12 / 786.85 | 5 | 9 |
4 | 13 | 1485.16 | 36 | 13.15 | 1417 | 671 | 3.79 / 787.52 | 5 | 14 |
5 | 13 | 1059.52 | 36 | 13.39 | 1113 | 537 | 4.33 / 788.06 | 5 | 20 |
6 | 13 | 196.96 | 36 | 14.06 | 464 | 235 | 4.56 / 788.29 | 5 | 14 |
7 | 13 | 40.28 | 36 | 14.21 | 344 | 176 | 4.74 / 788.47 | 5 | 11 |
8 | 8 | -0.04 | 450 | 14.10 | 291 | 1846 | 6.58 / 790.32 | 5 | 32 |
Average= | 6.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.04 | 60 | 14.21 | 361 | 308 | 0.31 / 777.32 | 6 | 6 |
2 | 7 | 2016.24 | 105 | 11.35 | 1715 | 2044 | 2.35 / 779.36 | 6 | 5 |
3 | 13 | 1924.76 | 36 | 12.84 | 1689 | 781 | 3.13 / 780.14 | 5 | 10 |
4 | 13 | 1611.56 | 36 | 13.09 | 1496 | 705 | 3.84 / 780.85 | 5 | 13 |
5 | 13 | 1081.12 | 36 | 13.38 | 1122 | 540 | 4.38 / 781.39 | 5 | 20 |
6 | 13 | 432.40 | 36 | 13.82 | 644 | 320 | 4.70 / 781.71 | 5 | 21 |
7 | 13 | 19.24 | 36 | 14.24 | 323 | 166 | 4.86 / 781.88 | 5 | 11 |
8 | 8 | 0.04 | 450 | 14.09 | 293 | 1858 | 6.72 / 783.73 | 5 | 29 |
Average= | 6.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.04 | 60 | 14.20 | 361 | 308 | 0.31 / 770.67 | 5 | 6 |
2 | 7 | 2012.08 | 105 | 11.38 | 1718 | 2053 | 2.36 / 772.72 | 6 | 6 |
3 | 13 | 1923.84 | 36 | 12.85 | 1703 | 788 | 3.15 / 773.51 | 5 | 10 |
4 | 13 | 1522.56 | 36 | 13.14 | 1438 | 680 | 3.83 / 774.19 | 5 | 14 |
5 | 13 | 1091.44 | 36 | 13.37 | 1140 | 549 | 4.38 / 774.74 | 5 | 19 |
6 | 13 | 218.08 | 36 | 14.02 | 485 | 245 | 4.62 / 774.99 | 5 | 16 |
7 | 13 | 20.56 | 36 | 14.23 | 330 | 169 | 4.79 / 775.16 | 5 | 11 |
8 | 8 | -0.20 | 450 | 14.08 | 293 | 1856 | 6.65 / 777.01 | 5 | 34 |
Average= | 6.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.20 | 60 | 14.19 | 367 | 312 | 0.31 / 764.22 | 5 | 6 |
2 | 7 | 2005.16 | 106 | 11.42 | 1719 | 2081 | 2.39 / 766.30 | 6 | 6 |
3 | 13 | 1796.64 | 36 | 12.96 | 1616 | 754 | 3.15 / 767.05 | 5 | 10 |
4 | 13 | 1486.80 | 36 | 13.16 | 1406 | 666 | 3.81 / 767.72 | 5 | 14 |
5 | 13 | 1057.92 | 36 | 13.39 | 1107 | 534 | 4.35 / 768.25 | 5 | 20 |
6 | 13 | 277.48 | 36 | 13.96 | 521 | 262 | 4.61 / 768.52 | 5 | 19 |
7 | 8 | 0.00 | 450 | 14.07 | 292 | 1849 | 6.46 / 770.36 | 5 | 32 |
Average= | 6.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.36 | 60 | 14.19 | 365 | 311 | 0.31 / 757.61 | 5 | 5 |
2 | 7 | 2013.64 | 105 | 11.49 | 1726 | 2082 | 2.39 / 759.69 | 5 | 6 |
3 | 13 | 1915.40 | 36 | 12.87 | 1688 | 782 | 3.18 / 760.48 | 5 | 9 |
4 | 13 | 1493.08 | 36 | 13.16 | 1406 | 666 | 3.84 / 761.14 | 5 | 14 |
5 | 13 | 940.44 | 36 | 13.44 | 1039 | 503 | 4.34 / 761.65 | 5 | 21 |
6 | 13 | 199.84 | 36 | 14.03 | 471 | 238 | 4.58 / 761.88 | 5 | 18 |
7 | 13 | 20.48 | 36 | 14.21 | 331 | 169 | 4.75 / 762.05 | 5 | 13 |
8 | 8 | -0.12 | 450 | 14.06 | 293 | 1854 | 6.61 / 763.91 | 5 | 26 |
Average= | 6.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.24 | 60 | 14.14 | 378 | 321 | 0.32 / 750.80 | 5 | 5 |
2 | 7 | 2004.80 | 105 | 11.51 | 1712 | 2069 | 2.39 / 752.87 | 5 | 6 |
3 | 13 | 1911.96 | 36 | 12.86 | 1696 | 785 | 3.17 / 753.66 | 5 | 10 |
4 | 13 | 1388.92 | 36 | 13.19 | 1355 | 643 | 3.82 / 754.30 | 5 | 15 |
5 | 13 | 1071.00 | 36 | 13.39 | 1122 | 541 | 4.36 / 754.84 | 5 | 20 |
6 | 13 | 718.12 | 36 | 13.58 | 872 | 426 | 4.79 / 755.27 | 5 | 24 |
7 | 13 | 20.80 | 36 | 14.19 | 337 | 172 | 4.96 / 755.44 | 5 | 15 |
8 | 8 | -0.16 | 450 | 14.03 | 295 | 1862 | 6.82 / 757.30 | 5 | 25 |
Average= | 6.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.76 | 60 | 14.13 | 374 | 317 | 0.32 / 744.24 | 5 | 5 |
2 | 7 | 2013.56 | 105 | 11.52 | 1718 | 2078 | 2.40 / 746.32 | 5 | 6 |
3 | 13 | 1927.52 | 36 | 12.85 | 1701 | 787 | 3.18 / 747.10 | 5 | 10 |
4 | 13 | 1404.64 | 36 | 13.19 | 1353 | 642 | 3.82 / 747.74 | 5 | 15 |
5 | 13 | 1091.24 | 36 | 13.37 | 1142 | 550 | 4.37 / 748.29 | 5 | 20 |
6 | 13 | 324.64 | 36 | 13.88 | 572 | 286 | 4.66 / 748.58 | 5 | 23 |
7 | 8 | -0.04 | 450 | 13.99 | 302 | 1901 | 6.56 / 750.48 | 5 | 24 |
Average= | 6.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.20 | 60 | 14.14 | 370 | 314 | 0.31 / 737.57 | 5 | 5 |
2 | 7 | 2007.84 | 105 | 11.58 | 1715 | 2085 | 2.40 / 739.66 | 5 | 6 |
3 | 13 | 1920.08 | 36 | 12.88 | 1674 | 776 | 3.18 / 740.43 | 5 | 10 |
4 | 13 | 1371.36 | 36 | 13.22 | 1321 | 629 | 3.80 / 741.06 | 5 | 16 |
5 | 13 | 949.04 | 36 | 13.45 | 1031 | 499 | 4.30 / 741.56 | 5 | 22 |
6 | 13 | 387.88 | 36 | 13.82 | 628 | 312 | 4.62 / 741.87 | 5 | 25 |
7 | 13 | 12.96 | 36 | 14.18 | 331 | 169 | 4.78 / 742.04 | 5 | 18 |
8 | 8 | -0.16 | 450 | 13.96 | 299 | 1878 | 6.66 / 743.92 | 5 | 19 |
Average= | 6.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.12 | 59 | 14.10 | 385 | 320 | 0.32 / 731.04 | 5 | 5 |
2 | 7 | 2008.16 | 105 | 11.64 | 1713 | 2094 | 2.41 / 733.14 | 5 | 6 |
3 | 13 | 1822.76 | 36 | 12.97 | 1622 | 757 | 3.17 / 733.90 | 5 | 11 |
4 | 13 | 1622.92 | 36 | 13.10 | 1491 | 703 | 3.87 / 734.60 | 5 | 13 |
5 | 13 | 869.56 | 36 | 13.48 | 992 | 481 | 4.36 / 735.08 | 5 | 22 |
6 | 13 | 338.72 | 36 | 13.86 | 589 | 294 | 4.65 / 735.37 | 5 | 23 |
7 | 8 | 0.04 | 450 | 14.00 | 299 | 1884 | 6.53 / 737.26 | 5 | 24 |
Average= | 6.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.04 | 59 | 14.12 | 379 | 316 | 0.32 / 724.52 | 5 | 5 |
2 | 7 | 2012.92 | 106 | 11.63 | 1714 | 2113 | 2.43 / 726.63 | 5 | 6 |
3 | 13 | 1918.88 | 36 | 12.87 | 1679 | 778 | 3.21 / 727.41 | 5 | 10 |
4 | 13 | 1472.48 | 36 | 13.15 | 1421 | 673 | 3.88 / 728.08 | 5 | 14 |
5 | 13 | 939.20 | 36 | 13.45 | 1030 | 499 | 4.38 / 728.58 | 5 | 22 |
6 | 13 | 177.28 | 36 | 14.02 | 462 | 233 | 4.61 / 728.82 | 5 | 19 |
7 | 8 | -0.36 | 450 | 13.99 | 303 | 1908 | 6.52 / 730.72 | 5 | 20 |
Average= | 6.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.64 | 59 | 14.08 | 391 | 325 | 0.32 / 718.13 | 5 | 5 |
2 | 7 | 2004.16 | 105 | 11.65 | 1715 | 2098 | 2.42 / 720.23 | 5 | 6 |
3 | 13 | 1807.64 | 36 | 12.95 | 1619 | 755 | 3.18 / 720.99 | 5 | 11 |
4 | 13 | 1491.44 | 36 | 13.14 | 1423 | 673 | 3.85 / 721.66 | 5 | 15 |
5 | 13 | 842.32 | 36 | 13.50 | 961 | 467 | 4.32 / 722.13 | 5 | 22 |
6 | 13 | 117.48 | 36 | 14.10 | 408 | 207 | 4.52 / 722.33 | 5 | 17 |
7 | 8 | 0.12 | 450 | 14.01 | 297 | 1872 | 6.40 / 724.21 | 5 | 21 |
Average= | 6.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.24 | 59 | 14.09 | 386 | 321 | 0.32 / 711.68 | 5 | 5 |
2 | 7 | 2005.32 | 105 | 11.62 | 1719 | 2097 | 2.42 / 713.78 | 5 | 6 |
3 | 13 | 1907.72 | 36 | 12.87 | 1686 | 781 | 3.20 / 714.56 | 5 | 10 |
4 | 13 | 1380.16 | 36 | 13.20 | 1349 | 641 | 3.84 / 715.20 | 5 | 15 |
5 | 13 | 737.08 | 36 | 13.55 | 897 | 438 | 4.28 / 715.64 | 5 | 22 |
6 | 13 | 203.24 | 36 | 14.00 | 483 | 243 | 4.52 / 715.88 | 5 | 20 |
7 | 8 | 0.08 | 450 | 13.97 | 306 | 1924 | 6.45 / 717.81 | 5 | 27 |
Average= | 6.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.92 | 59 | 14.10 | 387 | 322 | 0.32 / 704.96 | 5 | 5 |
2 | 7 | 2014.12 | 106 | 11.67 | 1710 | 2115 | 2.44 / 707.08 | 5 | 6 |
3 | 13 | 1920.08 | 36 | 12.86 | 1693 | 784 | 3.22 / 707.86 | 5 | 9 |
4 | 13 | 1366.40 | 36 | 13.22 | 1322 | 629 | 3.85 / 708.49 | 5 | 15 |
5 | 13 | 941.16 | 36 | 13.45 | 1029 | 498 | 4.35 / 708.99 | 5 | 21 |
6 | 13 | 386.64 | 36 | 13.82 | 621 | 309 | 4.66 / 709.30 | 5 | 24 |
7 | 13 | 13.64 | 36 | 14.19 | 334 | 171 | 4.83 / 709.47 | 5 | 17 |
8 | 8 | 0.00 | 450 | 13.95 | 302 | 1896 | 6.72 / 711.36 | 5 | 20 |
Average= | 6.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.64 | 59 | 14.14 | 377 | 315 | 0.31 / 698.62 | 5 | 5 |
2 | 7 | 2007.00 | 105 | 11.69 | 1710 | 2099 | 2.41 / 700.72 | 5 | 6 |
3 | 13 | 1718.64 | 36 | 13.01 | 1564 | 733 | 3.15 / 701.45 | 5 | 11 |
4 | 13 | 1306.40 | 36 | 13.24 | 1287 | 613 | 3.76 / 702.07 | 5 | 16 |
5 | 13 | 870.60 | 36 | 13.48 | 994 | 482 | 4.24 / 702.55 | 5 | 22 |
6 | 13 | 100.12 | 36 | 14.11 | 397 | 202 | 4.44 / 702.75 | 5 | 17 |
7 | 8 | 0.08 | 450 | 13.99 | 300 | 1889 | 6.33 / 704.64 | 5 | 22 |
Average= | 6.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.04 | 59 | 14.14 | 381 | 318 | 0.32 / 692.07 | 5 | 5 |
2 | 7 | 2009.88 | 106 | 11.69 | 1718 | 2129 | 2.45 / 694.20 | 5 | 6 |
3 | 13 | 1911.40 | 36 | 12.86 | 1697 | 786 | 3.23 / 694.98 | 5 | 10 |
4 | 13 | 1461.28 | 36 | 13.17 | 1392 | 660 | 3.89 / 695.64 | 5 | 14 |
5 | 13 | 1008.76 | 36 | 13.40 | 1093 | 527 | 4.42 / 696.17 | 5 | 21 |
6 | 13 | 234.72 | 36 | 13.97 | 512 | 257 | 4.68 / 696.43 | 5 | 20 |
7 | 8 | -0.28 | 450 | 13.98 | 299 | 1881 | 6.56 / 698.31 | 5 | 24 |
Average= | 6.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.28 | 59 | 14.12 | 377 | 314 | 0.31 / 685.66 | 5 | 5 |
2 | 7 | 2004.48 | 106 | 11.69 | 1719 | 2130 | 2.44 / 687.79 | 5 | 6 |
3 | 13 | 1912.20 | 36 | 12.88 | 1672 | 775 | 3.22 / 688.56 | 5 | 10 |
4 | 13 | 1261.40 | 36 | 13.28 | 1246 | 596 | 3.82 / 689.16 | 5 | 16 |
5 | 13 | 842.16 | 36 | 13.52 | 951 | 463 | 4.28 / 689.62 | 5 | 22 |
6 | 13 | 274.56 | 36 | 13.94 | 522 | 262 | 4.54 / 689.89 | 5 | 23 |
7 | 8 | 0.04 | 450 | 13.99 | 296 | 1863 | 6.40 / 691.75 | 5 | 25 |
Average= | 6.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.32 | 59 | 14.14 | 378 | 315 | 0.32 / 679.30 | 5 | 5 |
2 | 3 | 1015.36 | 1 | 12.35 | 1073 | 13 | 0.33 / 679.32 | 5 | 5 |
3 | 7 | 2004.96 | 105 | 11.75 | 1715 | 2116 | 2.44 / 681.43 | 5 | 6 |
4 | 13 | 1710.08 | 36 | 13.01 | 1564 | 733 | 3.18 / 682.16 | 5 | 12 |
5 | 13 | 1307.72 | 36 | 13.26 | 1289 | 615 | 3.79 / 682.78 | 5 | 16 |
6 | 13 | 876.64 | 36 | 13.50 | 982 | 477 | 4.27 / 683.26 | 5 | 22 |
7 | 13 | 100.56 | 36 | 14.13 | 391 | 199 | 4.47 / 683.46 | 5 | 16 |
8 | 8 | 0.12 | 450 | 14.00 | 300 | 1890 | 6.36 / 685.35 | 5 | 15 |
Average= | 6.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.72 | 59 | 14.11 | 380 | 316 | 0.32 / 672.85 | 5 | 5 |
2 | 7 | 2021.80 | 105 | 11.75 | 1717 | 2118 | 2.43 / 674.97 | 5 | 6 |
3 | 13 | 1942.92 | 36 | 12.86 | 1699 | 787 | 3.22 / 675.76 | 5 | 10 |
4 | 13 | 1401.48 | 36 | 13.21 | 1343 | 639 | 3.86 / 676.40 | 5 | 15 |
5 | 13 | 876.64 | 36 | 13.49 | 984 | 478 | 4.34 / 676.87 | 5 | 22 |
6 | 13 | 234.96 | 36 | 13.98 | 496 | 250 | 4.59 / 677.12 | 5 | 21 |
7 | 8 | -0.08 | 450 | 13.99 | 296 | 1863 | 6.45 / 678.99 | 5 | 30 |
Average= | 6.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.16 | 59 | 14.11 | 375 | 312 | 0.31 / 666.28 | 5 | 5 |
2 | 7 | 2008.04 | 105 | 11.77 | 1711 | 2115 | 2.43 / 668.40 | 5 | 6 |
3 | 13 | 1918.56 | 36 | 12.87 | 1699 | 787 | 3.21 / 669.18 | 5 | 9 |
4 | 13 | 1600.32 | 36 | 13.11 | 1475 | 696 | 3.91 / 669.88 | 5 | 13 |
5 | 13 | 1035.56 | 36 | 13.41 | 1090 | 526 | 4.44 / 670.41 | 5 | 21 |
6 | 13 | 247.20 | 36 | 13.97 | 509 | 256 | 4.69 / 670.66 | 5 | 22 |
7 | 8 | 0.08 | 450 | 13.97 | 298 | 1873 | 6.57 / 672.54 | 5 | 26 |
Average= | 6.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.84 | 59 | 14.13 | 376 | 313 | 0.31 / 659.77 | 5 | 5 |
2 | 7 | 2011.32 | 106 | 11.76 | 1711 | 2133 | 2.45 / 661.90 | 5 | 6 |
3 | 13 | 1920.32 | 36 | 12.87 | 1672 | 775 | 3.22 / 662.68 | 5 | 10 |
4 | 13 | 1488.76 | 36 | 13.16 | 1415 | 670 | 3.89 / 663.35 | 5 | 14 |
5 | 13 | 940.88 | 36 | 13.44 | 1047 | 507 | 4.40 / 663.85 | 5 | 22 |
6 | 13 | 273.08 | 36 | 13.93 | 536 | 269 | 4.67 / 664.12 | 5 | 23 |
7 | 8 | 0.00 | 450 | 13.97 | 294 | 1848 | 6.51 / 665.97 | 5 | 20 |
Average= | 6.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.12 | 59 | 14.12 | 389 | 324 | 0.32 / 653.32 | 5 | 5 |
2 | 7 | 2016.96 | 106 | 11.78 | 1713 | 2139 | 2.46 / 655.46 | 5 | 6 |
3 | 13 | 1926.68 | 36 | 12.87 | 1692 | 784 | 3.25 / 656.24 | 5 | 10 |
4 | 13 | 1189.76 | 36 | 13.30 | 1206 | 577 | 3.82 / 656.82 | 5 | 18 |
5 | 13 | 890.32 | 36 | 13.48 | 1004 | 487 | 4.31 / 657.31 | 5 | 22 |
6 | 13 | 348.40 | 36 | 13.87 | 586 | 293 | 4.60 / 657.60 | 5 | 24 |
7 | 8 | -0.04 | 450 | 13.97 | 295 | 1855 | 6.46 / 659.46 | 5 | 21 |
Average= | 6.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.08 | 59 | 14.11 | 382 | 318 | 0.32 / 646.96 | 5 | 5 |
2 | 7 | 2014.80 | 105 | 11.80 | 1714 | 2124 | 2.44 / 649.09 | 5 | 6 |
3 | 13 | 1919.52 | 36 | 12.85 | 1687 | 780 | 3.22 / 649.87 | 5 | 10 |
4 | 13 | 1361.44 | 36 | 13.21 | 1331 | 633 | 3.86 / 650.50 | 5 | 15 |
5 | 13 | 747.72 | 36 | 13.58 | 875 | 428 | 4.28 / 650.93 | 5 | 24 |
6 | 13 | 115.80 | 36 | 14.12 | 404 | 205 | 4.49 / 651.13 | 5 | 18 |
7 | 8 | 0.16 | 450 | 13.98 | 296 | 1862 | 6.35 / 653.00 | 5 | 21 |
Average= | 6.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.16 | 59 | 14.15 | 367 | 306 | 0.31 / 640.54 | 5 | 5 |
2 | 7 | 2002.48 | 105 | 11.77 | 1704 | 2106 | 2.41 / 642.64 | 5 | 6 |
3 | 13 | 1904.04 | 36 | 12.87 | 1660 | 769 | 3.18 / 643.41 | 5 | 9 |
4 | 13 | 1383.60 | 36 | 13.21 | 1332 | 633 | 3.81 / 644.05 | 5 | 16 |
5 | 13 | 961.52 | 36 | 13.45 | 1035 | 501 | 4.32 / 644.55 | 5 | 22 |
6 | 13 | 210.04 | 36 | 14.00 | 476 | 240 | 4.56 / 644.79 | 5 | 22 |
7 | 8 | -0.08 | 450 | 13.96 | 296 | 1859 | 6.42 / 646.65 | 5 | 18 |
Average= | 6.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.40 | 59 | 14.18 | 366 | 306 | 0.31 / 633.70 | 5 | 5 |
2 | 7 | 2014.80 | 105 | 11.78 | 1710 | 2115 | 2.42 / 635.82 | 5 | 6 |
3 | 13 | 1724.08 | 36 | 13.00 | 1558 | 729 | 3.15 / 636.55 | 5 | 11 |
4 | 13 | 1537.20 | 36 | 13.14 | 1440 | 681 | 3.83 / 637.23 | 5 | 14 |
5 | 13 | 889.60 | 36 | 13.48 | 1002 | 486 | 4.32 / 637.71 | 5 | 22 |
6 | 13 | 554.00 | 36 | 13.71 | 753 | 372 | 4.69 / 638.09 | 5 | 25 |
7 | 13 | 15.76 | 36 | 14.21 | 328 | 168 | 4.86 / 638.25 | 5 | 17 |
8 | 13 | 3.96 | 36 | 14.10 | 311 | 158 | 5.02 / 638.41 | 5 | 13 |
9 | 8 | -0.20 | 450 | 13.94 | 290 | 1819 | 6.83 / 640.23 | 5 | 26 |
Average= | 6.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.12 | 59 | 14.20 | 366 | 307 | 0.31 / 627.11 | 5 | 5 |
2 | 7 | 2013.12 | 105 | 11.78 | 1714 | 2120 | 2.43 / 629.23 | 5 | 6 |
3 | 13 | 1817.80 | 36 | 12.96 | 1609 | 751 | 3.18 / 629.98 | 5 | 10 |
4 | 13 | 1385.60 | 36 | 13.21 | 1341 | 638 | 3.82 / 630.62 | 5 | 16 |
5 | 13 | 848.84 | 36 | 13.52 | 971 | 473 | 4.29 / 631.09 | 5 | 22 |
6 | 13 | 317.16 | 36 | 13.93 | 554 | 278 | 4.57 / 631.37 | 5 | 21 |
7 | 13 | 35.56 | 36 | 14.21 | 341 | 174 | 4.74 / 631.55 | 5 | 16 |
8 | 8 | 0.08 | 450 | 13.99 | 294 | 1851 | 6.59 / 633.40 | 5 | 20 |
Average= | 6.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.52 | 58 | 14.19 | 369 | 304 | 0.30 / 620.59 | 5 | 5 |
2 | 7 | 2009.28 | 106 | 11.79 | 1734 | 2167 | 2.47 / 622.76 | 5 | 6 |
3 | 13 | 1922.72 | 36 | 12.84 | 1696 | 784 | 3.25 / 623.54 | 5 | 10 |
4 | 13 | 1473.00 | 36 | 13.15 | 1415 | 670 | 3.92 / 624.21 | 5 | 14 |
5 | 13 | 925.40 | 36 | 13.46 | 1035 | 502 | 4.43 / 624.72 | 5 | 22 |
6 | 13 | 250.76 | 36 | 14.00 | 515 | 260 | 4.69 / 624.97 | 5 | 19 |
7 | 8 | 0.00 | 450 | 14.03 | 290 | 1831 | 6.52 / 626.81 | 5 | 15 |
Average= | 6.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.80 | 58 | 14.23 | 369 | 305 | 0.30 / 614.14 | 5 | 5 |
2 | 7 | 2007.20 | 105 | 11.77 | 1725 | 2132 | 2.44 / 616.27 | 5 | 6 |
3 | 13 | 1815.48 | 36 | 12.93 | 1629 | 758 | 3.19 / 617.03 | 5 | 9 |
4 | 13 | 1505.48 | 36 | 13.15 | 1412 | 668 | 3.86 / 617.69 | 5 | 15 |
5 | 13 | 856.12 | 36 | 13.50 | 979 | 476 | 4.34 / 618.17 | 5 | 22 |
6 | 13 | 294.84 | 36 | 13.93 | 547 | 274 | 4.61 / 618.44 | 5 | 23 |
7 | 8 | 0.00 | 450 | 13.99 | 293 | 1845 | 6.46 / 620.29 | 5 | 33 |
Average= | 6.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.64 | 58 | 14.26 | 359 | 297 | 0.30 / 607.67 | 5 | 5 |
2 | 7 | 2003.68 | 106 | 11.77 | 1700 | 2121 | 2.42 / 609.79 | 5 | 6 |
3 | 13 | 1812.76 | 36 | 12.92 | 1610 | 749 | 3.17 / 610.54 | 5 | 10 |
4 | 13 | 1381.68 | 36 | 13.21 | 1326 | 631 | 3.80 / 611.17 | 5 | 15 |
5 | 13 | 749.48 | 36 | 13.58 | 889 | 435 | 4.23 / 611.60 | 5 | 23 |
6 | 13 | 203.44 | 36 | 14.03 | 476 | 240 | 4.47 / 611.84 | 5 | 20 |
7 | 13 | 2.36 | 36 | 14.25 | 312 | 160 | 4.63 / 612.00 | 5 | 7 |
8 | 8 | -0.24 | 450 | 13.98 | 291 | 1831 | 6.46 / 613.83 | 5 | 26 |
Average= | 6.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.72 | 58 | 14.25 | 375 | 310 | 0.31 / 601.23 | 5 | 5 |
2 | 7 | 2012.80 | 105 | 11.68 | 1720 | 2109 | 2.42 / 603.34 | 5 | 6 |
3 | 13 | 1918.16 | 36 | 12.81 | 1693 | 781 | 3.20 / 604.12 | 5 | 9 |
4 | 13 | 1387.96 | 36 | 13.21 | 1347 | 641 | 3.84 / 604.76 | 5 | 15 |
5 | 13 | 956.08 | 36 | 13.47 | 1040 | 504 | 4.34 / 605.27 | 5 | 21 |
6 | 13 | 274.24 | 36 | 13.97 | 526 | 265 | 4.61 / 605.53 | 5 | 21 |
7 | 8 | -0.04 | 450 | 14.01 | 291 | 1835 | 6.44 / 607.37 | 5 | 26 |
Average= | 6.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.32 | 58 | 14.20 | 372 | 306 | 0.31 / 595.23 | 5 | 5 |
2 | 7 | 1654.28 | 106 | 11.82 | 1491 | 1868 | 2.17 / 597.09 | 5 | 7 |
3 | 13 | 1595.08 | 36 | 12.99 | 1477 | 691 | 2.87 / 597.78 | 5 | 10 |
4 | 13 | 1287.52 | 36 | 13.27 | 1282 | 612 | 3.48 / 598.40 | 5 | 15 |
5 | 13 | 839.72 | 36 | 13.56 | 958 | 468 | 3.95 / 598.86 | 5 | 21 |
6 | 13 | 270.24 | 36 | 14.01 | 512 | 258 | 4.20 / 599.12 | 5 | 20 |
7 | 8 | 0.20 | 450 | 14.05 | 285 | 1802 | 6.01 / 600.92 | 5 | 31 |
Average= | 6.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.64 | 58 | 14.27 | 355 | 294 | 0.29 / 578.11 | 5 | 6 |
2 | 7 | 1430.28 | 105 | 12.18 | 1326 | 1696 | 1.99 / 579.80 | 6 | 9 |
3 | 13 | 1431.32 | 36 | 13.04 | 1356 | 637 | 2.63 / 580.44 | 5 | 12 |
4 | 13 | 1431.28 | 36 | 13.11 | 1360 | 642 | 3.27 / 581.08 | 5 | 14 |
5 | 13 | 1431.28 | 36 | 13.14 | 1370 | 648 | 3.92 / 581.73 | 5 | 15 |
6 | 13 | 1431.32 | 36 | 13.16 | 1367 | 648 | 4.56 / 582.38 | 5 | 16 |
7 | 13 | 1431.24 | 36 | 13.18 | 1368 | 649 | 5.21 / 583.03 | 5 | 17 |
8 | 13 | 1431.20 | 36 | 13.20 | 1362 | 647 | 5.86 / 583.68 | 5 | 18 |
9 | 13 | 1431.20 | 36 | 13.22 | 1355 | 645 | 6.50 / 584.32 | 5 | 20 |
10 | 13 | 1431.16 | 36 | 13.23 | 1357 | 646 | 7.15 / 584.97 | 5 | 21 |
11 | 13 | 1431.16 | 36 | 13.24 | 1359 | 648 | 7.80 / 585.61 | 5 | 23 |
12 | 13 | 1431.12 | 36 | 13.26 | 1351 | 645 | 8.44 / 586.26 | 5 | 26 |
13 | 13 | 1431.08 | 36 | 13.26 | 1361 | 650 | 9.09 / 586.91 | 5 | 29 |
14 | 13 | 1431.04 | 36 | 13.27 | 1357 | 648 | 9.74 / 587.56 | 5 | 31 |
15 | 13 | 1431.00 | 36 | 13.27 | 1361 | 650 | 10.39 / 588.21 | 5 | 35 |
16 | 13 | 1430.96 | 36 | 13.28 | 1366 | 653 | 11.05 / 588.86 | 5 | 38 |
17 | 13 | 1430.92 | 36 | 13.28 | 1370 | 655 | 11.70 / 589.52 | 5 | 40 |
18 | 13 | 1430.88 | 36 | 13.27 | 1376 | 657 | 12.36 / 590.17 | 5 | 42 |
19 | 13 | 1430.88 | 36 | 13.29 | 1373 | 657 | 13.01 / 590.83 | 5 | 43 |
20 | 13 | 1430.84 | 36 | 13.31 | 1355 | 649 | 13.66 / 591.48 | 5 | 44 |
21 | 13 | 1430.76 | 36 | 13.31 | 1347 | 645 | 14.31 / 592.12 | 5 | 47 |
22 | 13 | 1430.72 | 36 | 13.32 | 1334 | 640 | 14.95 / 592.76 | 5 | 51 |
23 | 13 | 1430.72 | 36 | 13.32 | 1352 | 648 | 15.60 / 593.41 | 5 | 58 |
24 | 13 | 1338.04 | 36 | 13.36 | 1284 | 618 | 16.21 / 594.03 | 5 | 70 |
25 | 8 | -0.48 | 3 | 14.17 | 330 | 14 | 16.23 / 594.04 | 5 | 22 |
26 | 14 | -0.56 | 222 | 14.03 | 281 | 875 | 17.10 / 594.92 | 5 | -99 |
Average= | 6.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.40 | 58 | 14.35 | 344 | 286 | 0.29 / 571.27 | 6 | 6 |
2 | 7 | 2003.72 | 106 | 11.82 | 1705 | 2136 | 2.42 / 573.41 | 6 | 6 |
3 | 13 | 1693.68 | 36 | 13.02 | 1544 | 724 | 3.15 / 574.13 | 5 | 11 |
4 | 13 | 1279.44 | 36 | 13.28 | 1265 | 605 | 3.75 / 574.74 | 5 | 17 |
5 | 13 | 1188.96 | 36 | 13.33 | 1191 | 572 | 4.32 / 575.31 | 5 | 19 |
6 | 13 | 582.68 | 36 | 13.72 | 770 | 380 | 4.70 / 575.69 | 5 | 23 |
7 | 13 | 21.96 | 36 | 14.25 | 331 | 170 | 4.87 / 575.86 | 5 | 14 |
8 | 13 | 11.04 | 36 | 14.14 | 315 | 160 | 5.03 / 576.02 | 5 | 13 |
9 | 8 | 0.00 | 450 | 14.00 | 285 | 1795 | 6.83 / 577.82 | 5 | 29 |
Average= | 6.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.16 | 58 | 14.35 | 352 | 293 | 0.29 / 564.72 | 6 | 6 |
2 | 7 | 2004.20 | 106 | 11.85 | 1707 | 2144 | 2.44 / 566.87 | 6 | 6 |
3 | 13 | 1721.08 | 36 | 13.02 | 1544 | 724 | 3.16 / 567.59 | 5 | 11 |
4 | 13 | 1279.08 | 36 | 13.29 | 1269 | 607 | 3.77 / 568.20 | 5 | 17 |
5 | 13 | 956.76 | 36 | 13.49 | 1038 | 504 | 4.27 / 568.70 | 5 | 22 |
6 | 13 | 86.76 | 36 | 14.22 | 372 | 190 | 4.46 / 568.89 | 5 | 14 |
7 | 13 | 49.36 | 36 | 14.20 | 336 | 172 | 4.63 / 569.06 | 5 | 12 |
8 | 13 | 24.84 | 36 | 14.17 | 309 | 158 | 4.79 / 569.22 | 5 | 13 |
9 | 8 | -0.28 | 450 | 14.06 | 279 | 1765 | 6.56 / 570.99 | 5 | 41 |
Average= | 6.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.52 | 58 | 14.35 | 338 | 281 | 0.28 / 558.19 | 6 | 6 |
2 | 7 | 2006.44 | 105 | 11.84 | 1705 | 2120 | 2.40 / 560.31 | 6 | 6 |
3 | 13 | 1913.20 | 36 | 12.85 | 1683 | 779 | 3.18 / 561.09 | 5 | 9 |
4 | 13 | 1480.40 | 36 | 13.17 | 1415 | 671 | 3.85 / 561.76 | 5 | 14 |
5 | 13 | 802.16 | 36 | 13.58 | 938 | 459 | 4.31 / 562.21 | 5 | 22 |
6 | 13 | 242.44 | 36 | 14.06 | 499 | 253 | 4.56 / 562.47 | 5 | 18 |
7 | 13 | 60.92 | 36 | 14.24 | 352 | 180 | 4.74 / 562.65 | 5 | 13 |
8 | 8 | 0.00 | 450 | 14.09 | 281 | 1782 | 6.52 / 564.43 | 5 | 32 |
Average= | 6.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.56 | 58 | 14.35 | 337 | 280 | 0.28 / 551.40 | 6 | 6 |
2 | 7 | 2007.04 | 106 | 11.84 | 1709 | 2145 | 2.43 / 553.55 | 6 | 6 |
3 | 13 | 1909.32 | 36 | 12.85 | 1680 | 777 | 3.20 / 554.32 | 5 | 9 |
4 | 13 | 1494.76 | 36 | 13.18 | 1417 | 672 | 3.87 / 555.00 | 5 | 14 |
5 | 13 | 1076.76 | 36 | 13.42 | 1137 | 549 | 4.42 / 555.55 | 5 | 20 |
6 | 13 | 623.40 | 36 | 13.71 | 807 | 398 | 4.82 / 555.94 | 5 | 24 |
7 | 13 | 29.08 | 36 | 14.26 | 336 | 172 | 4.99 / 556.12 | 5 | 14 |
8 | 8 | -0.28 | 450 | 14.05 | 283 | 1789 | 6.78 / 557.91 | 5 | 45 |
Average= | 6.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.36 | 58 | 14.36 | 340 | 283 | 0.28 / 544.78 | 6 | 6 |
2 | 7 | 2015.12 | 106 | 11.86 | 1709 | 2148 | 2.43 / 546.93 | 6 | 6 |
3 | 13 | 1921.80 | 36 | 12.85 | 1690 | 782 | 3.21 / 547.71 | 5 | 9 |
4 | 13 | 1403.84 | 36 | 13.24 | 1337 | 637 | 3.85 / 548.35 | 5 | 15 |
5 | 13 | 845.00 | 36 | 13.57 | 960 | 469 | 4.32 / 548.82 | 5 | 22 |
6 | 13 | 516.60 | 36 | 13.80 | 719 | 357 | 4.68 / 549.17 | 5 | 24 |
7 | 13 | 32.60 | 36 | 14.27 | 330 | 170 | 4.85 / 549.34 | 5 | 13 |
8 | 8 | -0.12 | 450 | 14.06 | 281 | 1778 | 6.62 / 551.12 | 5 | 30 |
Average= | 6.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.16 | 58 | 14.39 | 337 | 281 | 0.28 / 538.08 | 6 | 6 |
2 | 7 | 2005.28 | 106 | 11.86 | 1709 | 2148 | 2.43 / 540.23 | 6 | 6 |
3 | 13 | 1907.68 | 36 | 12.86 | 1686 | 781 | 3.21 / 541.01 | 5 | 9 |
4 | 13 | 1467.44 | 36 | 13.20 | 1396 | 663 | 3.87 / 541.68 | 5 | 14 |
5 | 13 | 1039.72 | 36 | 13.46 | 1101 | 534 | 4.41 / 542.21 | 5 | 21 |
6 | 13 | 237.04 | 36 | 14.08 | 495 | 251 | 4.66 / 542.46 | 5 | 18 |
7 | 13 | 31.08 | 36 | 14.27 | 333 | 171 | 4.83 / 542.63 | 5 | 13 |
8 | 13 | 16.48 | 36 | 14.18 | 300 | 153 | 4.98 / 542.78 | 5 | 13 |
9 | 8 | -0.28 | 450 | 14.04 | 271 | 1712 | 6.69 / 544.50 | 5 | 40 |
Average= | 6.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.80 | 58 | 14.39 | 341 | 285 | 0.28 / 531.49 | 6 | 6 |
2 | 7 | 2012.28 | 105 | 11.87 | 1712 | 2134 | 2.42 / 533.62 | 6 | 6 |
3 | 13 | 1834.00 | 36 | 12.96 | 1629 | 760 | 3.18 / 534.38 | 5 | 10 |
4 | 13 | 1738.68 | 36 | 13.03 | 1567 | 735 | 3.91 / 535.12 | 5 | 11 |
5 | 13 | 846.04 | 36 | 13.58 | 953 | 466 | 4.38 / 535.58 | 5 | 22 |
6 | 13 | 305.28 | 36 | 14.03 | 542 | 274 | 4.65 / 535.86 | 5 | 18 |
7 | 13 | 18.00 | 36 | 14.30 | 318 | 164 | 4.82 / 536.02 | 5 | 11 |
8 | 8 | -0.20 | 450 | 14.09 | 281 | 1782 | 6.60 / 537.80 | 5 | 34 |
Average= | 6.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.56 | 58 | 14.38 | 336 | 280 | 0.28 / 525.07 | 6 | 6 |
2 | 7 | 2006.44 | 105 | 11.85 | 1710 | 2128 | 2.41 / 527.20 | 6 | 6 |
3 | 13 | 1913.04 | 36 | 12.86 | 1673 | 775 | 3.18 / 527.97 | 5 | 10 |
4 | 13 | 1395.72 | 36 | 13.25 | 1337 | 638 | 3.82 / 528.61 | 5 | 15 |
5 | 13 | 788.84 | 36 | 13.62 | 915 | 449 | 4.27 / 529.06 | 5 | 23 |
6 | 13 | 581.72 | 36 | 13.78 | 754 | 374 | 4.64 / 529.44 | 5 | 24 |
7 | 8 | -0.16 | 450 | 14.09 | 279 | 1769 | 6.41 / 531.20 | 5 | 35 |
Average= | 6.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.36 | 58 | 14.38 | 344 | 287 | 0.29 / 518.53 | 6 | 6 |
2 | 7 | 2007.36 | 106 | 11.86 | 1704 | 2142 | 2.43 / 520.67 | 6 | 6 |
3 | 13 | 1915.52 | 36 | 12.86 | 1684 | 780 | 3.21 / 521.45 | 5 | 9 |
4 | 13 | 1377.08 | 36 | 13.26 | 1333 | 636 | 3.85 / 522.09 | 5 | 15 |
5 | 13 | 929.48 | 36 | 13.52 | 1032 | 502 | 4.35 / 522.59 | 5 | 22 |
6 | 13 | 257.52 | 36 | 14.05 | 518 | 262 | 4.61 / 522.85 | 5 | 19 |
7 | 13 | 10.56 | 36 | 14.30 | 320 | 165 | 4.77 / 523.02 | 5 | 12 |
8 | 8 | -0.24 | 450 | 14.04 | 281 | 1775 | 6.55 / 524.79 | 5 | 32 |
Average= | 6.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.36 | 58 | 14.41 | 340 | 284 | 0.28 / 512.24 | 6 | 6 |
2 | 7 | 2004.28 | 105 | 11.84 | 1718 | 2136 | 2.42 / 514.37 | 6 | 6 |
3 | 13 | 1805.24 | 36 | 12.98 | 1609 | 752 | 3.17 / 515.13 | 5 | 11 |
4 | 13 | 1176.04 | 36 | 13.37 | 1205 | 580 | 3.75 / 515.71 | 5 | 18 |
5 | 13 | 862.68 | 36 | 13.58 | 982 | 480 | 4.23 / 516.19 | 5 | 22 |
6 | 13 | 194.96 | 36 | 14.12 | 471 | 239 | 4.47 / 516.43 | 5 | 17 |
7 | 8 | -0.04 | 450 | 14.07 | 287 | 1817 | 6.29 / 518.24 | 5 | 39 |
Average= | 6.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.48 | 58 | 14.38 | 341 | 284 | 0.28 / 505.98 | 6 | 6 |
2 | 7 | 2006.92 | 105 | 11.84 | 1708 | 2123 | 2.41 / 508.11 | 6 | 6 |
3 | 13 | 1913.08 | 36 | 12.88 | 1669 | 774 | 3.18 / 508.88 | 5 | 9 |
4 | 13 | 1281.92 | 36 | 13.33 | 1270 | 609 | 3.79 / 509.49 | 5 | 16 |
5 | 13 | 736.52 | 36 | 13.67 | 893 | 439 | 4.23 / 509.93 | 5 | 23 |
6 | 13 | 121.52 | 36 | 14.22 | 411 | 210 | 4.44 / 510.14 | 5 | 12 |
7 | 8 | -0.16 | 450 | 14.11 | 286 | 1816 | 6.26 / 511.95 | 5 | 24 |
Average= | 6.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.04 | 58 | 14.31 | 361 | 300 | 0.30 / 499.54 | 5 | 6 |
2 | 7 | 2011.40 | 106 | 11.82 | 1716 | 2150 | 2.45 / 501.69 | 6 | 6 |
3 | 13 | 1708.48 | 36 | 13.09 | 1554 | 732 | 3.18 / 502.42 | 5 | 11 |
4 | 13 | 1299.40 | 36 | 13.35 | 1287 | 619 | 3.80 / 503.04 | 5 | 17 |
5 | 13 | 778.80 | 36 | 13.66 | 918 | 451 | 4.25 / 503.49 | 5 | 23 |
6 | 13 | 239.84 | 36 | 14.11 | 500 | 254 | 4.51 / 503.75 | 5 | 16 |
7 | 13 | 4.48 | 36 | 14.33 | 307 | 158 | 4.66 / 503.91 | 5 | 11 |
8 | 8 | -0.08 | 450 | 14.06 | 283 | 1791 | 6.45 / 505.70 | 5 | 23 |
Average= | 6.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.80 | 58 | 14.40 | 345 | 288 | 0.29 / 489.30 | 5 | 6 |
2 | 7 | 1598.76 | 105 | 12.12 | 1442 | 1835 | 2.12 / 491.14 | 6 | 8 |
3 | 13 | 1599.80 | 36 | 13.00 | 1470 | 688 | 2.81 / 491.83 | 5 | 12 |
4 | 13 | 1599.80 | 36 | 13.09 | 1482 | 698 | 3.51 / 492.53 | 5 | 13 |
5 | 13 | 1599.68 | 36 | 13.13 | 1488 | 703 | 4.21 / 493.23 | 5 | 15 |
6 | 13 | 1599.64 | 36 | 13.18 | 1474 | 699 | 4.91 / 493.93 | 5 | 16 |
7 | 13 | 1599.56 | 36 | 13.19 | 1471 | 698 | 5.61 / 494.63 | 5 | 17 |
8 | 13 | 1599.52 | 36 | 13.21 | 1476 | 702 | 6.31 / 495.33 | 5 | 18 |
9 | 13 | 1599.48 | 36 | 13.22 | 1465 | 697 | 7.01 / 496.03 | 5 | 19 |
10 | 13 | 1599.40 | 36 | 13.24 | 1466 | 699 | 7.71 / 496.72 | 5 | 20 |
11 | 13 | 1599.40 | 36 | 13.25 | 1470 | 701 | 8.41 / 497.43 | 5 | 22 |
12 | 8 | -0.36 | 450 | 13.97 | 289 | 1817 | 10.23 / 499.24 | 5 | 54 |
Average= | 6.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.60 | 58 | 14.38 | 340 | 284 | 0.28 / 482.92 | 6 | 6 |
2 | 7 | 2015.84 | 106 | 11.88 | 1719 | 2165 | 2.45 / 485.08 | 6 | 6 |
3 | 13 | 1924.84 | 36 | 12.89 | 1688 | 783 | 3.23 / 485.87 | 5 | 10 |
4 | 13 | 1391.80 | 36 | 13.30 | 1346 | 644 | 3.88 / 486.51 | 5 | 15 |
5 | 13 | 964.92 | 36 | 13.54 | 1056 | 515 | 4.39 / 487.03 | 5 | 22 |
6 | 13 | 194.72 | 36 | 14.18 | 459 | 234 | 4.63 / 487.26 | 5 | 14 |
7 | 8 | 0.16 | 450 | 14.13 | 276 | 1755 | 6.38 / 489.02 | 5 | 32 |
Average= | 6.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.56 | 58 | 14.36 | 351 | 292 | 0.29 / 476.54 | 5 | 6 |
2 | 7 | 2008.36 | 105 | 11.87 | 1722 | 2146 | 2.44 / 478.68 | 6 | 6 |
3 | 13 | 1920.80 | 36 | 12.88 | 1705 | 791 | 3.23 / 479.47 | 5 | 9 |
4 | 13 | 1381.92 | 36 | 13.29 | 1353 | 647 | 3.88 / 480.12 | 5 | 15 |
5 | 13 | 850.64 | 36 | 13.64 | 964 | 473 | 4.35 / 480.59 | 5 | 23 |
6 | 13 | 200.68 | 36 | 14.17 | 467 | 238 | 4.59 / 480.83 | 5 | 14 |
7 | 8 | -0.04 | 450 | 14.12 | 284 | 1805 | 6.39 / 482.64 | 5 | 30 |
Average= | 6.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.52 | 58 | 14.34 | 349 | 290 | 0.29 / 470.13 | 5 | 5 |
2 | 7 | 2014.00 | 105 | 11.86 | 1725 | 2148 | 2.44 / 472.28 | 5 | 6 |
3 | 13 | 1920.84 | 36 | 12.89 | 1688 | 783 | 3.22 / 473.06 | 5 | 10 |
4 | 13 | 1466.16 | 36 | 13.27 | 1392 | 665 | 3.89 / 473.73 | 5 | 15 |
5 | 13 | 930.44 | 36 | 13.59 | 1019 | 499 | 4.39 / 474.23 | 5 | 22 |
6 | 13 | 169.28 | 36 | 14.19 | 442 | 226 | 4.61 / 474.45 | 5 | 14 |
7 | 8 | 0.08 | 450 | 14.11 | 282 | 1791 | 6.40 / 476.24 | 5 | 33 |
Average= | 6.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.04 | 58 | 14.33 | 356 | 296 | 0.30 / 463.84 | 5 | 5 |
2 | 7 | 2005.56 | 105 | 11.85 | 1718 | 2138 | 2.43 / 465.98 | 5 | 6 |
3 | 13 | 1910.32 | 36 | 12.91 | 1684 | 783 | 3.22 / 466.76 | 5 | 10 |
4 | 13 | 1480.68 | 36 | 13.27 | 1405 | 671 | 3.89 / 467.43 | 5 | 15 |
5 | 13 | 829.88 | 36 | 13.66 | 949 | 467 | 4.35 / 467.90 | 5 | 23 |
6 | 13 | 84.76 | 36 | 14.29 | 368 | 189 | 4.54 / 468.09 | 5 | 13 |
7 | 8 | 0.04 | 450 | 14.11 | 276 | 1752 | 6.30 / 469.84 | 5 | 36 |
Average= | 6.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.28 | 58 | 14.38 | 346 | 289 | 0.29 / 457.47 | 5 | 6 |
2 | 7 | 2014.44 | 105 | 11.87 | 1722 | 2146 | 2.43 / 459.61 | 6 | 6 |
3 | 13 | 1708.20 | 36 | 13.11 | 1549 | 731 | 3.17 / 460.35 | 5 | 12 |
4 | 13 | 1612.56 | 36 | 13.18 | 1480 | 702 | 3.87 / 461.05 | 5 | 13 |
5 | 13 | 838.12 | 36 | 13.65 | 975 | 479 | 4.35 / 461.53 | 5 | 23 |
6 | 13 | 89.56 | 36 | 14.28 | 376 | 193 | 4.54 / 461.72 | 5 | 12 |
7 | 8 | -0.08 | 450 | 14.09 | 288 | 1826 | 6.37 / 463.55 | 5 | 37 |
Average= | 6.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.44 | 58 | 14.36 | 359 | 299 | 0.30 / 451.14 | 5 | 6 |
2 | 7 | 2006.36 | 106 | 11.92 | 1717 | 2169 | 2.47 / 453.31 | 6 | 6 |
3 | 13 | 1706.56 | 36 | 13.14 | 1547 | 732 | 3.20 / 454.04 | 5 | 12 |
4 | 13 | 1400.72 | 36 | 13.35 | 1359 | 653 | 3.85 / 454.69 | 5 | 16 |
5 | 13 | 736.28 | 36 | 13.75 | 874 | 433 | 4.29 / 455.13 | 5 | 23 |
6 | 13 | 310.60 | 36 | 14.11 | 539 | 274 | 4.56 / 455.40 | 5 | 17 |
7 | 8 | 0.00 | 450 | 14.12 | 280 | 1779 | 6.34 / 457.18 | 5 | 35 |
Average= | 6.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.12 | 58 | 14.36 | 356 | 297 | 0.30 / 444.74 | 5 | 6 |
2 | 7 | 2005.20 | 105 | 11.93 | 1719 | 2153 | 2.45 / 446.90 | 6 | 6 |
3 | 13 | 1909.92 | 36 | 12.96 | 1685 | 786 | 3.24 / 447.68 | 5 | 10 |
4 | 13 | 1493.56 | 36 | 13.32 | 1412 | 677 | 3.91 / 448.36 | 5 | 15 |
5 | 13 | 856.04 | 36 | 13.68 | 969 | 477 | 4.39 / 448.84 | 5 | 23 |
6 | 13 | 213.72 | 36 | 14.20 | 468 | 239 | 4.63 / 449.08 | 5 | 14 |
7 | 8 | -0.04 | 450 | 14.15 | 277 | 1764 | 6.39 / 450.84 | 5 | 29 |
Average= | 6.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.36 | 58 | 14.33 | 373 | 310 | 0.31 / 438.40 | 5 | 5 |
2 | 7 | 2005.68 | 105 | 11.96 | 1716 | 2155 | 2.46 / 440.56 | 5 | 6 |
3 | 13 | 1910.00 | 36 | 12.99 | 1674 | 783 | 3.25 / 441.34 | 5 | 10 |
4 | 13 | 1193.68 | 36 | 13.47 | 1223 | 593 | 3.84 / 441.94 | 5 | 18 |
5 | 13 | 794.16 | 36 | 13.73 | 919 | 454 | 4.30 / 442.39 | 5 | 23 |
6 | 13 | 64.72 | 36 | 14.33 | 360 | 186 | 4.48 / 442.58 | 5 | 11 |
7 | 8 | 0.16 | 450 | 14.10 | 295 | 1872 | 6.35 / 444.45 | 5 | 38 |
Average= | 6.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.68 | 58 | 14.37 | 358 | 298 | 0.30 / 431.89 | 5 | 5 |
2 | 7 | 2011.24 | 105 | 11.97 | 1747 | 2196 | 2.49 / 434.08 | 5 | 6 |
3 | 13 | 1918.16 | 36 | 12.99 | 1706 | 798 | 3.29 / 434.88 | 5 | 9 |
4 | 13 | 1374.60 | 36 | 13.40 | 1353 | 653 | 3.94 / 435.54 | 5 | 16 |
5 | 13 | 831.28 | 36 | 13.70 | 975 | 481 | 4.43 / 436.02 | 5 | 22 |
6 | 13 | 89.60 | 36 | 14.32 | 386 | 199 | 4.62 / 436.22 | 5 | 10 |
7 | 8 | 0.24 | 450 | 14.11 | 296 | 1879 | 6.50 / 438.09 | 5 | 32 |
Average= | 6.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.48 | 58 | 14.37 | 360 | 300 | 0.30 / 425.56 | 5 | 5 |
2 | 7 | 2012.44 | 105 | 12.02 | 1728 | 2181 | 2.48 / 427.74 | 5 | 7 |
3 | 13 | 1816.44 | 36 | 13.14 | 1628 | 770 | 3.25 / 428.51 | 5 | 10 |
4 | 13 | 1385.36 | 36 | 13.42 | 1344 | 649 | 3.90 / 429.16 | 5 | 16 |
5 | 13 | 814.20 | 36 | 13.72 | 951 | 470 | 4.37 / 429.63 | 5 | 23 |
6 | 13 | 19.36 | 36 | 14.39 | 321 | 166 | 4.54 / 429.80 | 5 | 8 |
7 | 8 | -0.20 | 450 | 14.12 | 282 | 1792 | 6.33 / 431.59 | 5 | 43 |
Average= | 6.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.40 | 58 | 14.36 | 366 | 305 | 0.30 / 419.48 | 5 | 5 |
2 | 7 | 2008.32 | 105 | 12.03 | 1727 | 2181 | 2.49 / 421.66 | 5 | 7 |
3 | 13 | 1914.00 | 36 | 13.03 | 1693 | 794 | 3.28 / 422.46 | 5 | 9 |
4 | 13 | 1260.20 | 36 | 13.48 | 1273 | 618 | 3.90 / 423.07 | 5 | 17 |
5 | 13 | 639.36 | 36 | 13.87 | 803 | 401 | 4.30 / 423.47 | 5 | 23 |
6 | 8 | -0.04 | 450 | 14.14 | 281 | 1788 | 6.09 / 425.26 | 5 | 35 |
Average= | 6.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.68 | 58 | 14.35 | 372 | 310 | 0.31 / 412.92 | 5 | 5 |
2 | 7 | 2013.96 | 105 | 12.07 | 1745 | 2212 | 2.52 / 415.13 | 5 | 7 |
3 | 13 | 1715.32 | 36 | 13.24 | 1569 | 748 | 3.27 / 415.88 | 5 | 12 |
4 | 13 | 1410.76 | 36 | 13.43 | 1371 | 663 | 3.93 / 416.54 | 5 | 16 |
5 | 13 | 766.24 | 36 | 13.77 | 914 | 453 | 4.38 / 416.99 | 5 | 23 |
6 | 13 | 20.76 | 36 | 14.37 | 333 | 172 | 4.56 / 417.17 | 5 | 10 |
7 | 13 | 7.96 | 36 | 14.26 | 314 | 161 | 4.72 / 417.33 | 5 | 10 |
8 | 8 | 0.24 | 450 | 14.06 | 292 | 1847 | 6.57 / 419.18 | 5 | 37 |
Average= | 6.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.04 | 58 | 14.35 | 372 | 310 | 0.31 / 406.41 | 5 | 5 |
2 | 7 | 2008.84 | 106 | 12.11 | 1739 | 2232 | 2.54 / 408.64 | 5 | 7 |
3 | 13 | 1914.96 | 36 | 13.06 | 1705 | 802 | 3.34 / 409.44 | 5 | 9 |
4 | 13 | 1374.36 | 36 | 13.45 | 1344 | 651 | 3.99 / 410.09 | 5 | 17 |
5 | 13 | 831.56 | 36 | 13.75 | 961 | 476 | 4.47 / 410.57 | 5 | 23 |
6 | 13 | 175.00 | 36 | 14.26 | 442 | 227 | 4.70 / 410.80 | 5 | 12 |
7 | 8 | 0.12 | 450 | 14.14 | 285 | 1813 | 6.51 / 412.61 | 5 | 38 |
Average= | 6.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.08 | 58 | 14.36 | 365 | 304 | 0.30 / 399.95 | 5 | 5 |
2 | 7 | 2002.64 | 105 | 12.17 | 1725 | 2204 | 2.51 / 402.15 | 5 | 7 |
3 | 13 | 1805.32 | 36 | 13.22 | 1630 | 776 | 3.28 / 402.93 | 5 | 11 |
4 | 13 | 1281.84 | 36 | 13.51 | 1285 | 625 | 3.91 / 403.55 | 5 | 18 |
5 | 13 | 961.92 | 36 | 13.69 | 1064 | 524 | 4.43 / 404.08 | 5 | 23 |
6 | 13 | 93.48 | 36 | 14.33 | 385 | 199 | 4.63 / 404.27 | 5 | 11 |
7 | 8 | 0.08 | 450 | 14.13 | 287 | 1825 | 6.46 / 406.10 | 5 | 34 |
Average= | 6.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.16 | 58 | 14.36 | 379 | 316 | 0.32 / 393.26 | 5 | 5 |
2 | 7 | 2006.56 | 106 | 12.18 | 1749 | 2258 | 2.57 / 395.52 | 5 | 7 |
3 | 13 | 1714.44 | 36 | 13.28 | 1593 | 762 | 3.34 / 396.28 | 5 | 11 |
4 | 13 | 1316.24 | 36 | 13.49 | 1333 | 647 | 3.98 / 396.93 | 5 | 17 |
5 | 13 | 878.68 | 36 | 13.72 | 1023 | 505 | 4.49 / 397.44 | 5 | 23 |
6 | 13 | 316.84 | 36 | 14.12 | 581 | 295 | 4.78 / 397.73 | 5 | 17 |
7 | 8 | -0.04 | 450 | 14.10 | 301 | 1910 | 6.69 / 399.64 | 5 | 36 |
Average= | 6.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.36 | 58 | 14.37 | 372 | 310 | 0.31 / 386.59 | 5 | 5 |
2 | 7 | 2005.36 | 106 | 12.24 | 1743 | 2261 | 2.57 / 388.85 | 5 | 7 |
3 | 13 | 1699.52 | 36 | 13.30 | 1583 | 758 | 3.33 / 389.61 | 5 | 12 |
4 | 13 | 1390.56 | 36 | 13.48 | 1384 | 672 | 4.00 / 390.28 | 5 | 17 |
5 | 13 | 968.40 | 36 | 13.68 | 1087 | 535 | 4.54 / 390.82 | 5 | 23 |
6 | 13 | 80.48 | 36 | 14.33 | 381 | 197 | 4.73 / 391.01 | 5 | 11 |
7 | 8 | 0.16 | 450 | 14.10 | 305 | 1935 | 6.67 / 392.95 | 5 | 35 |
Average= | 6.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.84 | 58 | 14.41 | 360 | 301 | 0.30 / 380.05 | 5 | 6 |
2 | 7 | 2005.08 | 106 | 12.30 | 1735 | 2262 | 2.56 / 382.31 | 6 | 7 |
3 | 13 | 1703.16 | 36 | 13.32 | 1584 | 760 | 3.32 / 383.07 | 5 | 12 |
4 | 13 | 1288.40 | 36 | 13.55 | 1294 | 631 | 3.95 / 383.70 | 5 | 18 |
5 | 13 | 847.60 | 36 | 13.76 | 992 | 491 | 4.45 / 384.19 | 5 | 23 |
6 | 13 | 45.88 | 36 | 14.38 | 356 | 184 | 4.63 / 384.37 | 5 | 9 |
7 | 8 | 0.04 | 450 | 14.12 | 300 | 1906 | 6.54 / 386.28 | 5 | 34 |
Average= | 6.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.68 | 58 | 14.40 | 366 | 306 | 0.31 / 373.56 | 5 | 6 |
2 | 7 | 2010.24 | 105 | 12.34 | 1734 | 2247 | 2.55 / 375.81 | 6 | 7 |
3 | 13 | 1916.68 | 36 | 13.15 | 1697 | 803 | 3.36 / 376.61 | 5 | 10 |
4 | 13 | 1278.04 | 36 | 13.56 | 1280 | 625 | 3.98 / 377.23 | 5 | 18 |
5 | 13 | 752.64 | 36 | 13.83 | 908 | 452 | 4.43 / 377.69 | 5 | 23 |
6 | 13 | 217.64 | 36 | 14.26 | 471 | 242 | 4.67 / 377.93 | 5 | 14 |
7 | 8 | -0.04 | 450 | 14.17 | 285 | 1817 | 6.49 / 379.75 | 5 | 36 |
Average= | 6.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.00 | 58 | 14.44 | 353 | 296 | 0.30 / 367.11 | 5 | 6 |
2 | 7 | 2011.16 | 105 | 12.38 | 1749 | 2274 | 2.57 / 369.38 | 5 | 7 |
3 | 13 | 1717.12 | 36 | 13.35 | 1569 | 754 | 3.32 / 370.13 | 5 | 12 |
4 | 13 | 1218.76 | 36 | 13.59 | 1262 | 617 | 3.94 / 370.75 | 5 | 19 |
5 | 13 | 692.68 | 36 | 13.87 | 869 | 434 | 4.37 / 371.19 | 5 | 23 |
6 | 13 | 143.28 | 36 | 14.31 | 429 | 221 | 4.60 / 371.41 | 5 | 12 |
7 | 8 | 0.12 | 450 | 14.15 | 290 | 1847 | 6.44 / 373.25 | 5 | 34 |
Average= | 6.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.52 | 58 | 14.45 | 366 | 307 | 0.31 / 360.53 | 6 | 6 |
2 | 7 | 2010.64 | 105 | 12.42 | 1751 | 2283 | 2.59 / 362.82 | 5 | 7 |
3 | 13 | 1811.60 | 36 | 13.30 | 1645 | 788 | 3.38 / 363.61 | 5 | 11 |
4 | 13 | 1382.88 | 36 | 13.54 | 1367 | 666 | 4.04 / 364.27 | 5 | 17 |
5 | 13 | 847.64 | 36 | 13.79 | 984 | 488 | 4.53 / 364.76 | 5 | 23 |
6 | 13 | 188.12 | 36 | 14.28 | 465 | 239 | 4.77 / 365.00 | 5 | 12 |
7 | 8 | -0.08 | 450 | 14.18 | 284 | 1812 | 6.58 / 366.81 | 5 | 35 |
Average= | 6.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.16 | 58 | 14.45 | 353 | 296 | 0.30 / 354.02 | 5 | 6 |
2 | 7 | 2009.40 | 106 | 12.45 | 1746 | 2304 | 2.60 / 356.33 | 6 | 7 |
3 | 13 | 1710.32 | 36 | 13.37 | 1580 | 760 | 3.36 / 357.09 | 5 | 12 |
4 | 13 | 1196.80 | 36 | 13.62 | 1230 | 603 | 3.96 / 357.69 | 5 | 19 |
5 | 13 | 751.92 | 36 | 13.85 | 915 | 456 | 4.42 / 358.15 | 5 | 23 |
6 | 13 | 105.00 | 36 | 14.35 | 399 | 206 | 4.63 / 358.35 | 5 | 10 |
7 | 8 | 0.12 | 450 | 14.16 | 294 | 1873 | 6.50 / 360.23 | 5 | 30 |
Average= | 6.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.28 | 58 | 14.48 | 344 | 289 | 0.29 / 347.60 | 5 | 6 |
2 | 7 | 2007.24 | 106 | 12.48 | 1747 | 2311 | 2.60 / 349.91 | 6 | 7 |
3 | 13 | 1908.72 | 36 | 13.20 | 1708 | 812 | 3.41 / 350.73 | 5 | 9 |
4 | 13 | 1161.52 | 36 | 13.64 | 1204 | 591 | 4.00 / 351.32 | 5 | 19 |
5 | 13 | 741.16 | 36 | 13.87 | 890 | 444 | 4.45 / 351.76 | 5 | 23 |
6 | 13 | 46.12 | 36 | 14.42 | 333 | 173 | 4.62 / 351.93 | 5 | 9 |
7 | 8 | 0.16 | 450 | 14.19 | 281 | 1794 | 6.41 / 353.73 | 5 | 32 |
Average= | 6.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.16 | 58 | 14.46 | 353 | 296 | 0.30 / 341.19 | 6 | 6 |
2 | 7 | 2011.88 | 105 | 12.49 | 1742 | 2285 | 2.58 / 343.47 | 6 | 7 |
3 | 13 | 1721.32 | 36 | 13.38 | 1580 | 761 | 3.34 / 344.23 | 5 | 12 |
4 | 13 | 1289.92 | 36 | 13.60 | 1285 | 629 | 3.97 / 344.86 | 5 | 18 |
5 | 13 | 763.64 | 36 | 13.85 | 913 | 455 | 4.43 / 345.32 | 5 | 23 |
6 | 13 | 108.80 | 36 | 14.37 | 384 | 199 | 4.62 / 345.51 | 5 | 11 |
7 | 8 | -0.16 | 450 | 14.18 | 282 | 1799 | 6.42 / 347.31 | 5 | 31 |
Average= | 6.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.92 | 58 | 14.48 | 349 | 293 | 0.29 / 334.37 | 6 | 6 |
2 | 7 | 2007.96 | 105 | 12.49 | 1746 | 2290 | 2.58 / 336.66 | 6 | 7 |
3 | 13 | 1705.52 | 36 | 13.39 | 1575 | 759 | 3.34 / 337.42 | 5 | 13 |
4 | 13 | 1375.40 | 36 | 13.55 | 1368 | 667 | 4.01 / 338.08 | 5 | 17 |
5 | 13 | 936.28 | 36 | 13.75 | 1065 | 527 | 4.54 / 338.61 | 5 | 22 |
6 | 13 | 566.84 | 36 | 13.97 | 780 | 392 | 4.93 / 339.00 | 5 | 22 |
7 | 8 | -0.16 | 450 | 14.16 | 296 | 1886 | 6.81 / 340.89 | 5 | 31 |
Average= | 6.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.28 | 58 | 14.49 | 356 | 299 | 0.30 / 327.73 | 6 | 6 |
2 | 7 | 2010.80 | 105 | 12.49 | 1747 | 2291 | 2.59 / 330.02 | 5 | 7 |
3 | 13 | 1811.84 | 36 | 13.32 | 1653 | 793 | 3.38 / 330.81 | 5 | 12 |
4 | 13 | 1386.88 | 36 | 13.55 | 1364 | 665 | 4.05 / 331.48 | 5 | 16 |
5 | 13 | 936.04 | 36 | 13.76 | 1055 | 523 | 4.57 / 332.00 | 5 | 22 |
6 | 13 | 56.36 | 36 | 14.39 | 365 | 189 | 4.76 / 332.19 | 5 | 10 |
7 | 8 | 0.00 | 450 | 14.16 | 296 | 1886 | 6.65 / 334.07 | 5 | 31 |
Average= | 6.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.92 | 58 | 14.49 | 353 | 297 | 0.30 / 321.12 | 6 | 6 |
2 | 7 | 2005.48 | 105 | 12.47 | 1749 | 2290 | 2.59 / 323.41 | 6 | 7 |
3 | 13 | 1703.00 | 36 | 13.37 | 1581 | 761 | 3.35 / 324.17 | 5 | 13 |
4 | 13 | 1504.32 | 36 | 13.49 | 1453 | 706 | 4.05 / 324.88 | 5 | 15 |
5 | 13 | 820.84 | 36 | 13.81 | 977 | 486 | 4.54 / 325.36 | 5 | 22 |
6 | 13 | 75.76 | 36 | 14.38 | 378 | 196 | 4.73 / 325.56 | 5 | 10 |
7 | 8 | -0.08 | 450 | 14.17 | 293 | 1868 | 6.60 / 327.43 | 5 | 32 |
Average= | 6.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.48 | 57 | 14.51 | 351 | 290 | 0.29 / 314.46 | 6 | 6 |
2 | 7 | 2011.96 | 105 | 12.46 | 1761 | 2304 | 2.59 / 316.76 | 5 | 7 |
3 | 13 | 1920.36 | 36 | 13.20 | 1716 | 815 | 3.41 / 317.58 | 5 | 10 |
4 | 13 | 1357.88 | 36 | 13.55 | 1362 | 664 | 4.07 / 318.24 | 5 | 16 |
5 | 13 | 908.08 | 36 | 13.78 | 1039 | 515 | 4.59 / 318.76 | 5 | 22 |
6 | 13 | 48.92 | 36 | 14.41 | 360 | 187 | 4.78 / 318.94 | 5 | 10 |
7 | 8 | -0.12 | 450 | 14.17 | 295 | 1881 | 6.66 / 320.83 | 5 | 31 |
Average= | 6.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.52 | 57 | 14.50 | 349 | 288 | 0.29 / 307.89 | 6 | 6 |
2 | 7 | 2006.80 | 105 | 12.45 | 1743 | 2279 | 2.57 / 310.16 | 6 | 7 |
3 | 13 | 1915.20 | 36 | 13.17 | 1702 | 807 | 3.37 / 310.97 | 5 | 10 |
4 | 13 | 1360.80 | 36 | 13.53 | 1364 | 664 | 4.04 / 311.64 | 5 | 16 |
5 | 13 | 796.00 | 36 | 13.82 | 956 | 476 | 4.51 / 312.11 | 5 | 23 |
6 | 13 | 56.64 | 36 | 14.41 | 362 | 188 | 4.70 / 312.30 | 5 | 10 |
7 | 8 | -0.04 | 450 | 14.18 | 293 | 1870 | 6.57 / 314.17 | 5 | 29 |
Average= | 6.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.36 | 57 | 14.51 | 354 | 293 | 0.29 / 301.40 | 6 | 6 |
2 | 7 | 2006.20 | 105 | 12.44 | 1746 | 2281 | 2.57 / 303.68 | 6 | 7 |
3 | 13 | 1802.40 | 36 | 13.31 | 1627 | 780 | 3.35 / 304.46 | 5 | 12 |
4 | 13 | 1275.80 | 36 | 13.59 | 1279 | 626 | 3.98 / 305.08 | 5 | 17 |
5 | 13 | 744.60 | 36 | 13.88 | 901 | 450 | 4.43 / 305.53 | 5 | 22 |
6 | 13 | 173.84 | 36 | 14.33 | 443 | 229 | 4.66 / 305.76 | 5 | 13 |
7 | 8 | -0.20 | 450 | 14.20 | 287 | 1834 | 6.49 / 307.60 | 5 | 35 |
Average= | 6.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.88 | 57 | 14.52 | 348 | 288 | 0.29 / 294.77 | 6 | 6 |
2 | 7 | 2004.28 | 106 | 12.46 | 1736 | 2293 | 2.58 / 297.06 | 6 | 7 |
3 | 13 | 1813.32 | 36 | 13.32 | 1628 | 781 | 3.36 / 297.84 | 5 | 10 |
4 | 13 | 1475.84 | 36 | 13.51 | 1425 | 693 | 4.05 / 298.53 | 5 | 15 |
5 | 13 | 896.76 | 36 | 13.78 | 1031 | 511 | 4.57 / 299.04 | 5 | 22 |
6 | 13 | 51.32 | 36 | 14.43 | 354 | 184 | 4.75 / 299.23 | 5 | 9 |
7 | 8 | -0.08 | 450 | 14.19 | 294 | 1877 | 6.63 / 301.11 | 5 | 35 |
Average= | 6.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.88 | 57 | 14.55 | 344 | 285 | 0.29 / 288.25 | 6 | 6 |
2 | 7 | 2011.56 | 105 | 12.46 | 1748 | 2287 | 2.57 / 290.54 | 6 | 7 |
3 | 13 | 1914.96 | 36 | 13.19 | 1697 | 806 | 3.38 / 291.34 | 5 | 10 |
4 | 13 | 1459.52 | 36 | 13.53 | 1403 | 683 | 4.06 / 292.03 | 5 | 15 |
5 | 13 | 782.88 | 36 | 13.87 | 930 | 464 | 4.53 / 292.49 | 5 | 22 |
6 | 13 | 59.08 | 36 | 14.44 | 356 | 185 | 4.71 / 292.67 | 5 | 10 |
7 | 8 | -0.12 | 450 | 14.21 | 282 | 1803 | 6.51 / 294.48 | 5 | 32 |
Average= | 6.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.48 | 57 | 14.57 | 349 | 290 | 0.29 / 281.72 | 6 | 6 |
2 | 7 | 2009.64 | 106 | 12.50 | 1744 | 2311 | 2.60 / 284.03 | 5 | 7 |
3 | 13 | 1923.20 | 36 | 13.22 | 1692 | 805 | 3.41 / 284.83 | 5 | 9 |
4 | 13 | 1367.44 | 36 | 13.58 | 1341 | 656 | 4.06 / 285.49 | 5 | 16 |
5 | 13 | 800.28 | 36 | 13.87 | 937 | 468 | 4.53 / 285.95 | 5 | 22 |
6 | 13 | 66.44 | 36 | 14.44 | 359 | 187 | 4.72 / 286.14 | 5 | 10 |
7 | 8 | -0.20 | 450 | 14.21 | 285 | 1822 | 6.54 / 287.96 | 5 | 29 |
Average= | 6.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.44 | 57 | 14.57 | 337 | 280 | 0.28 / 275.15 | 6 | 6 |
2 | 7 | 2010.16 | 106 | 12.53 | 1741 | 2312 | 2.59 / 277.46 | 6 | 7 |
3 | 13 | 1913.72 | 36 | 13.22 | 1700 | 809 | 3.40 / 278.27 | 5 | 9 |
4 | 13 | 1376.60 | 36 | 13.59 | 1341 | 656 | 4.06 / 278.92 | 5 | 16 |
5 | 13 | 639.08 | 36 | 13.98 | 816 | 411 | 4.47 / 279.33 | 5 | 21 |
6 | 13 | 25.16 | 36 | 14.49 | 317 | 165 | 4.63 / 279.50 | 5 | 9 |
7 | 13 | 15.00 | 36 | 14.40 | 303 | 157 | 4.79 / 279.66 | 5 | 10 |
8 | 8 | -0.32 | 450 | 14.19 | 277 | 1769 | 6.56 / 281.43 | 5 | 45 |
Average= | 6.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.68 | 57 | 14.54 | 349 | 289 | 0.29 / 268.74 | 6 | 6 |
2 | 7 | 2015.16 | 105 | 12.58 | 1756 | 2320 | 2.61 / 271.06 | 5 | 7 |
3 | 13 | 1704.96 | 36 | 13.43 | 1569 | 759 | 3.37 / 271.82 | 5 | 11 |
4 | 13 | 1291.56 | 36 | 13.65 | 1284 | 631 | 4.00 / 272.45 | 5 | 17 |
5 | 13 | 770.32 | 36 | 13.91 | 926 | 464 | 4.46 / 272.91 | 5 | 22 |
6 | 13 | 53.60 | 36 | 14.48 | 339 | 177 | 4.64 / 273.09 | 5 | 9 |
7 | 8 | -0.04 | 450 | 14.24 | 277 | 1775 | 6.41 / 274.87 | 5 | 36 |
Average= | 6.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.36 | 57 | 14.52 | 357 | 295 | 0.30 / 261.91 | 5 | 6 |
2 | 7 | 2006.72 | 105 | 12.62 | 1753 | 2323 | 2.62 / 264.24 | 5 | 7 |
3 | 13 | 1907.68 | 36 | 13.28 | 1712 | 818 | 3.44 / 265.06 | 5 | 9 |
4 | 13 | 1364.24 | 36 | 13.63 | 1347 | 661 | 4.10 / 265.72 | 5 | 16 |
5 | 13 | 1038.56 | 36 | 13.80 | 1117 | 555 | 4.65 / 266.27 | 5 | 20 |
6 | 13 | 26.16 | 36 | 14.50 | 328 | 171 | 4.82 / 266.44 | 5 | 8 |
7 | 13 | 13.56 | 36 | 14.42 | 315 | 164 | 4.99 / 266.61 | 5 | 9 |
8 | 8 | -0.16 | 450 | 14.20 | 289 | 1847 | 6.83 / 268.45 | 5 | 39 |
Average= | 6.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.44 | 56 | 14.56 | 350 | 285 | 0.29 / 255.52 | 5 | 6 |
2 | 7 | 2003.48 | 106 | 12.68 | 1736 | 2333 | 2.62 / 257.85 | 5 | 7 |
3 | 13 | 1605.60 | 36 | 13.52 | 1522 | 741 | 3.36 / 258.59 | 5 | 12 |
4 | 13 | 1005.88 | 36 | 13.79 | 1114 | 553 | 3.91 / 259.14 | 5 | 20 |
5 | 13 | 685.36 | 36 | 13.99 | 866 | 436 | 4.35 / 259.58 | 5 | 22 |
6 | 13 | 26.12 | 36 | 14.51 | 327 | 171 | 4.52 / 259.75 | 5 | 9 |
7 | 8 | -0.20 | 450 | 14.21 | 292 | 1867 | 6.39 / 261.62 | 5 | 34 |
Average= | 6.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.80 | 56 | 14.56 | 356 | 290 | 0.29 / 248.88 | 6 | 6 |
2 | 7 | 2022.80 | 105 | 12.71 | 1745 | 2329 | 2.62 / 251.21 | 6 | 7 |
3 | 13 | 1830.68 | 36 | 13.44 | 1659 | 803 | 3.42 / 252.01 | 5 | 10 |
4 | 13 | 1507.00 | 36 | 13.62 | 1441 | 707 | 4.13 / 252.72 | 5 | 15 |
5 | 13 | 803.24 | 36 | 13.93 | 957 | 480 | 4.61 / 253.20 | 5 | 22 |
6 | 13 | 65.64 | 36 | 14.49 | 351 | 183 | 4.79 / 253.38 | 5 | 10 |
7 | 8 | -0.16 | 450 | 14.24 | 289 | 1852 | 6.64 / 255.23 | 5 | 33 |
Average= | 6.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.92 | 56 | 14.57 | 365 | 298 | 0.30 / 242.44 | 5 | 6 |
2 | 7 | 2003.64 | 105 | 12.76 | 1749 | 2343 | 2.64 / 244.78 | 5 | 7 |
3 | 13 | 1796.40 | 36 | 13.48 | 1628 | 790 | 3.43 / 245.57 | 5 | 11 |
4 | 13 | 1163.28 | 36 | 13.76 | 1220 | 604 | 4.04 / 246.18 | 5 | 19 |
5 | 13 | 652.84 | 36 | 14.04 | 838 | 424 | 4.46 / 246.60 | 5 | 21 |
6 | 13 | 22.76 | 36 | 14.53 | 323 | 169 | 4.63 / 246.77 | 5 | 9 |
7 | 8 | -0.04 | 450 | 14.23 | 284 | 1819 | 6.45 / 248.59 | 5 | 34 |
Average= | 6.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.32 | 56 | 14.57 | 355 | 290 | 0.29 / 236.01 | 5 | 5 |
2 | 7 | 2006.60 | 106 | 12.78 | 1745 | 2364 | 2.65 / 238.37 | 5 | 7 |
3 | 13 | 1612.36 | 36 | 13.59 | 1505 | 736 | 3.39 / 239.11 | 5 | 13 |
4 | 13 | 1194.32 | 36 | 13.77 | 1230 | 610 | 4.00 / 239.72 | 5 | 19 |
5 | 13 | 561.04 | 36 | 14.12 | 753 | 383 | 4.38 / 240.10 | 5 | 21 |
6 | 13 | 23.44 | 36 | 14.53 | 330 | 173 | 4.55 / 240.27 | 5 | 10 |
7 | 8 | -0.08 | 450 | 14.22 | 292 | 1869 | 6.42 / 242.14 | 5 | 39 |
Average= | 6.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.72 | 56 | 14.55 | 369 | 301 | 0.30 / 229.35 | 5 | 5 |
2 | 7 | 2006.16 | 105 | 12.82 | 1739 | 2341 | 2.64 / 231.69 | 5 | 7 |
3 | 13 | 1816.56 | 36 | 13.52 | 1635 | 796 | 3.44 / 232.49 | 5 | 11 |
4 | 13 | 1370.80 | 36 | 13.72 | 1346 | 665 | 4.10 / 233.15 | 5 | 17 |
5 | 13 | 1036.72 | 36 | 13.88 | 1109 | 554 | 4.66 / 233.71 | 5 | 21 |
6 | 13 | 49.72 | 36 | 14.52 | 343 | 179 | 4.84 / 233.88 | 5 | 10 |
7 | 8 | 0.04 | 450 | 14.25 | 286 | 1834 | 6.67 / 235.72 | 5 | 35 |
Average= | 6.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.04 | 56 | 14.55 | 366 | 298 | 0.30 / 222.78 | 5 | 5 |
2 | 7 | 2011.60 | 105 | 12.85 | 1747 | 2357 | 2.66 / 225.14 | 5 | 7 |
3 | 13 | 1707.72 | 36 | 13.59 | 1580 | 773 | 3.43 / 225.91 | 5 | 12 |
4 | 13 | 1180.48 | 36 | 13.79 | 1242 | 617 | 4.04 / 226.53 | 5 | 18 |
5 | 13 | 651.36 | 36 | 14.08 | 838 | 425 | 4.47 / 226.95 | 5 | 22 |
6 | 13 | 38.44 | 36 | 14.54 | 350 | 183 | 4.65 / 227.14 | 5 | 10 |
7 | 8 | -0.04 | 450 | 14.22 | 299 | 1913 | 6.57 / 229.05 | 5 | 36 |
Average= | 6.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.72 | 56 | 14.57 | 362 | 295 | 0.30 / 216.20 | 5 | 5 |
2 | 7 | 2005.28 | 105 | 12.88 | 1735 | 2346 | 2.64 / 218.54 | 5 | 7 |
3 | 13 | 1913.48 | 36 | 13.44 | 1703 | 824 | 3.47 / 219.37 | 5 | 10 |
4 | 13 | 1178.12 | 36 | 13.82 | 1220 | 607 | 4.07 / 219.97 | 5 | 18 |
5 | 13 | 858.52 | 36 | 13.98 | 988 | 497 | 4.57 / 220.47 | 5 | 22 |
6 | 13 | 21.12 | 36 | 14.56 | 323 | 169 | 4.74 / 220.64 | 5 | 9 |
7 | 8 | 0.12 | 450 | 14.26 | 287 | 1842 | 6.58 / 222.48 | 5 | 32 |
Average= | 6.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.52 | 56 | 14.60 | 352 | 288 | 0.29 / 209.66 | 5 | 6 |
2 | 7 | 2004.92 | 105 | 12.91 | 1736 | 2353 | 2.64 / 212.02 | 6 | 7 |
3 | 13 | 1810.16 | 36 | 13.57 | 1641 | 802 | 3.44 / 212.82 | 5 | 11 |
4 | 13 | 1348.12 | 36 | 13.77 | 1336 | 662 | 4.10 / 213.48 | 5 | 17 |
5 | 13 | 559.24 | 36 | 14.16 | 758 | 386 | 4.49 / 213.87 | 5 | 22 |
6 | 13 | 112.68 | 36 | 14.51 | 391 | 204 | 4.70 / 214.07 | 5 | 12 |
7 | 8 | -0.08 | 450 | 14.27 | 285 | 1830 | 6.53 / 215.90 | 5 | 39 |
Average= | 6.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.64 | 56 | 14.57 | 365 | 298 | 0.30 / 203.15 | 5 | 5 |
2 | 7 | 2005.24 | 105 | 12.94 | 1740 | 2364 | 2.66 / 205.52 | 5 | 7 |
3 | 13 | 1913.40 | 36 | 13.48 | 1695 | 823 | 3.48 / 206.34 | 5 | 10 |
4 | 13 | 1261.44 | 36 | 13.82 | 1276 | 635 | 4.12 / 206.97 | 5 | 18 |
5 | 13 | 619.48 | 36 | 14.13 | 816 | 415 | 4.53 / 207.39 | 5 | 22 |
6 | 13 | 1.56 | 36 | 14.61 | 301 | 158 | 4.69 / 207.55 | 5 | 7 |
7 | 8 | 0.08 | 450 | 14.27 | 285 | 1830 | 6.52 / 209.38 | 5 | 36 |
Average= | 6.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.48 | 56 | 14.55 | 382 | 311 | 0.31 / 196.54 | 5 | 5 |
2 | 7 | 2008.16 | 106 | 12.96 | 1751 | 2405 | 2.72 / 198.94 | 5 | 7 |
3 | 13 | 1705.00 | 36 | 13.65 | 1566 | 770 | 3.49 / 199.71 | 5 | 12 |
4 | 13 | 1373.92 | 36 | 13.78 | 1355 | 672 | 4.16 / 200.38 | 5 | 16 |
5 | 13 | 693.52 | 36 | 14.09 | 871 | 442 | 4.60 / 200.83 | 5 | 23 |
6 | 13 | 24.56 | 36 | 14.57 | 329 | 173 | 4.77 / 201.00 | 5 | 10 |
7 | 8 | -0.04 | 450 | 14.26 | 289 | 1855 | 6.63 / 202.85 | 5 | 31 |
Average= | 6.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.32 | 56 | 14.55 | 378 | 308 | 0.31 / 190.09 | 5 | 5 |
2 | 7 | 2004.64 | 105 | 12.99 | 1743 | 2377 | 2.69 / 192.47 | 5 | 7 |
3 | 13 | 1912.72 | 36 | 13.49 | 1697 | 824 | 3.51 / 193.30 | 5 | 10 |
4 | 13 | 1142.16 | 36 | 13.88 | 1187 | 593 | 4.10 / 193.89 | 5 | 19 |
5 | 13 | 606.04 | 36 | 14.16 | 794 | 405 | 4.51 / 194.29 | 5 | 23 |
6 | 8 | 0.00 | 450 | 14.26 | 301 | 1932 | 6.44 / 196.23 | 5 | 29 |
Average= | 6.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.52 | 56 | 14.56 | 366 | 298 | 0.30 / 183.75 | 5 | 5 |
2 | 7 | 2013.40 | 105 | 13.01 | 1745 | 2384 | 2.68 / 186.13 | 5 | 7 |
3 | 13 | 1696.96 | 36 | 13.66 | 1563 | 769 | 3.45 / 186.90 | 5 | 12 |
4 | 13 | 1159.20 | 36 | 13.87 | 1214 | 606 | 4.06 / 187.51 | 5 | 18 |
5 | 13 | 617.68 | 36 | 14.15 | 810 | 413 | 4.47 / 187.92 | 5 | 22 |
6 | 8 | 0.20 | 450 | 14.29 | 290 | 1865 | 6.33 / 189.79 | 5 | 36 |
Average= | 6.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.48 | 56 | 14.57 | 368 | 300 | 0.30 / 177.35 | 5 | 5 |
2 | 7 | 2012.32 | 105 | 13.03 | 1745 | 2387 | 2.69 / 179.74 | 5 | 7 |
3 | 13 | 1805.12 | 36 | 13.62 | 1632 | 800 | 3.49 / 180.54 | 5 | 11 |
4 | 13 | 1260.96 | 36 | 13.84 | 1275 | 635 | 4.12 / 181.17 | 5 | 18 |
5 | 13 | 595.76 | 36 | 14.17 | 797 | 407 | 4.53 / 181.58 | 5 | 22 |
6 | 8 | -0.04 | 450 | 14.29 | 291 | 1871 | 6.40 / 183.45 | 5 | 33 |
Average= | 6.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.60 | 56 | 14.56 | 372 | 303 | 0.30 / 170.99 | 5 | 5 |
2 | 3 | 1009.96 | 1 | 14.49 | 1106 | 16 | 0.32 / 171.00 | 5 | 5 |
3 | 7 | 2010.88 | 105 | 13.04 | 1753 | 2400 | 2.72 / 173.40 | 5 | 7 |
4 | 13 | 1808.64 | 36 | 13.63 | 1635 | 802 | 3.52 / 174.21 | 5 | 11 |
5 | 13 | 1148.04 | 36 | 13.88 | 1213 | 606 | 4.13 / 174.81 | 5 | 18 |
6 | 13 | 530.08 | 36 | 14.21 | 752 | 385 | 4.51 / 175.20 | 5 | 20 |
7 | 8 | 0.20 | 450 | 14.31 | 288 | 1855 | 6.37 / 177.05 | 5 | 31 |
Average= | 6.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.20 | 55 | 14.53 | 375 | 300 | 0.30 / 164.35 | 5 | 5 |
2 | 7 | 2005.44 | 106 | 13.06 | 1756 | 2431 | 2.73 / 166.78 | 5 | 7 |
3 | 13 | 1603.36 | 36 | 13.72 | 1511 | 746 | 3.48 / 167.52 | 5 | 13 |
4 | 13 | 1170.04 | 36 | 13.88 | 1231 | 615 | 4.09 / 168.14 | 5 | 19 |
5 | 13 | 636.20 | 36 | 14.15 | 842 | 429 | 4.52 / 168.57 | 5 | 22 |
6 | 13 | 189.44 | 36 | 14.47 | 474 | 247 | 4.77 / 168.81 | 5 | 13 |
7 | 8 | -0.20 | 450 | 14.28 | 291 | 1870 | 6.64 / 170.68 | 5 | 40 |
Average= | 6.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.12 | 55 | 14.58 | 365 | 293 | 0.29 / 158.00 | 5 | 5 |
2 | 7 | 2006.44 | 105 | 13.09 | 1743 | 2396 | 2.69 / 160.40 | 5 | 7 |
3 | 13 | 1803.88 | 36 | 13.63 | 1651 | 810 | 3.50 / 161.21 | 5 | 11 |
4 | 13 | 1029.32 | 36 | 13.95 | 1126 | 565 | 4.06 / 161.77 | 5 | 19 |
5 | 13 | 603.84 | 36 | 14.17 | 811 | 414 | 4.48 / 162.19 | 5 | 21 |
6 | 8 | -0.04 | 450 | 14.30 | 289 | 1860 | 6.34 / 164.05 | 5 | 33 |
Average= | 6.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.24 | 55 | 14.59 | 361 | 290 | 0.29 / 151.78 | 5 | 6 |
2 | 7 | 2012.84 | 105 | 13.12 | 1745 | 2404 | 2.69 / 154.18 | 6 | 7 |
3 | 13 | 1703.92 | 36 | 13.69 | 1558 | 768 | 3.46 / 154.95 | 5 | 12 |
4 | 13 | 1164.96 | 36 | 13.91 | 1200 | 601 | 4.06 / 155.55 | 5 | 18 |
5 | 13 | 416.60 | 36 | 14.32 | 642 | 331 | 4.39 / 155.88 | 5 | 18 |
6 | 8 | 0.04 | 450 | 14.31 | 284 | 1829 | 6.22 / 157.71 | 5 | 28 |
Average= | 6.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.20 | 55 | 14.61 | 361 | 290 | 0.29 / 145.40 | 5 | 6 |
2 | 3 | 1010.76 | 1 | 14.54 | 1115 | 16 | 0.31 / 145.41 | 5 | 5 |
3 | 7 | 2012.04 | 105 | 13.12 | 1756 | 2419 | 2.73 / 147.83 | 5 | 7 |
4 | 13 | 1610.64 | 36 | 13.73 | 1507 | 745 | 3.47 / 148.58 | 5 | 12 |
5 | 13 | 1210.00 | 36 | 13.89 | 1238 | 619 | 4.09 / 149.20 | 5 | 18 |
6 | 13 | 683.88 | 36 | 14.15 | 865 | 441 | 4.53 / 149.64 | 5 | 21 |
7 | 8 | 0.16 | 450 | 14.32 | 287 | 1849 | 6.38 / 151.49 | 5 | 28 |
Average= | 6.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.72 | 54 | 14.62 | 356 | 281 | 0.28 / 138.75 | 5 | 6 |
2 | 3 | 1011.32 | 1 | 14.55 | 1111 | 16 | 0.30 / 138.77 | 5 | 5 |
3 | 7 | 2004.56 | 105 | 13.15 | 1758 | 2427 | 2.72 / 141.20 | 5 | 7 |
4 | 13 | 1691.88 | 36 | 13.70 | 1575 | 777 | 3.50 / 141.98 | 5 | 12 |
5 | 13 | 1264.40 | 36 | 13.88 | 1277 | 638 | 4.14 / 142.61 | 5 | 17 |
6 | 13 | 699.12 | 36 | 14.14 | 878 | 447 | 4.59 / 143.06 | 5 | 22 |
7 | 13 | 53.88 | 36 | 14.61 | 347 | 183 | 4.77 / 143.24 | 5 | 9 |
8 | 8 | -0.28 | 450 | 14.29 | 290 | 1865 | 6.63 / 145.11 | 5 | 41 |
Average= | 6.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.72 | 57 | 14.60 | 358 | 298 | 0.30 / 132.38 | 5 | 6 |
2 | 3 | 958.56 | -1 | 14.60 | 358 | 0 | 0.00 / 132.38 | 5 | 6 |
3 | 7 | 2013.48 | 105 | 13.17 | 1752 | 2423 | 2.72 / 134.80 | 6 | 7 |
4 | 13 | 1698.84 | 36 | 13.72 | 1559 | 770 | 3.49 / 135.57 | 5 | 12 |
5 | 13 | 1256.16 | 36 | 13.89 | 1275 | 638 | 4.13 / 136.21 | 5 | 17 |
6 | 13 | 604.80 | 36 | 14.20 | 803 | 410 | 4.54 / 136.62 | 5 | 22 |
7 | 8 | 0.08 | 450 | 14.32 | 288 | 1856 | 6.39 / 138.47 | 5 | 32 |
Average= | 6.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.56 | 57 | 14.62 | 350 | 292 | 0.29 / 125.86 | 5 | 6 |
2 | 7 | 2003.92 | 105 | 13.20 | 1734 | 2403 | 2.69 / 128.26 | 6 | 7 |
3 | 13 | 1696.84 | 36 | 13.72 | 1575 | 778 | 3.47 / 129.04 | 5 | 11 |
4 | 13 | 1150.24 | 36 | 13.93 | 1205 | 604 | 4.08 / 129.64 | 5 | 18 |
5 | 13 | 610.40 | 36 | 14.21 | 801 | 410 | 4.49 / 130.05 | 5 | 22 |
6 | 13 | 0.88 | 36 | 14.67 | 310 | 164 | 4.65 / 130.22 | 5 | 8 |
7 | 8 | 0.32 | 450 | 14.27 | 290 | 1862 | 6.51 / 132.08 | 5 | 38 |
Average= | 6.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.96 | 57 | 14.65 | 342 | 286 | 0.29 / 119.38 | 6 | 6 |
2 | 7 | 2003.40 | 105 | 13.23 | 1732 | 2406 | 2.69 / 121.78 | 6 | 7 |
3 | 13 | 1688.24 | 36 | 13.73 | 1556 | 769 | 3.46 / 122.55 | 5 | 11 |
4 | 13 | 1364.20 | 36 | 13.87 | 1335 | 667 | 4.13 / 123.22 | 5 | 15 |
5 | 13 | 573.00 | 36 | 14.23 | 766 | 392 | 4.52 / 123.61 | 5 | 20 |
6 | 13 | 9.72 | 36 | 14.68 | 297 | 157 | 4.68 / 123.77 | 5 | 9 |
7 | 8 | -0.28 | 450 | 14.32 | 279 | 1798 | 6.47 / 125.57 | 5 | 31 |
Average= | 5.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.72 | 57 | 14.64 | 351 | 293 | 0.29 / 113.00 | 6 | 6 |
2 | 7 | 2009.92 | 105 | 13.25 | 1737 | 2417 | 2.71 / 115.42 | 6 | 7 |
3 | 13 | 1608.20 | 36 | 13.77 | 1508 | 748 | 3.46 / 116.16 | 5 | 12 |
4 | 13 | 1175.16 | 36 | 13.94 | 1210 | 607 | 4.06 / 116.77 | 5 | 17 |
5 | 13 | 523.52 | 36 | 14.28 | 728 | 374 | 4.44 / 117.14 | 5 | 19 |
6 | 13 | 17.76 | 36 | 14.68 | 303 | 160 | 4.60 / 117.30 | 5 | 8 |
7 | 8 | 0.04 | 450 | 14.34 | 277 | 1787 | 6.39 / 119.09 | 5 | 36 |
Average= | 5.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.60 | 57 | 14.67 | 347 | 290 | 0.29 / 106.43 | 6 | 6 |
2 | 7 | 2012.80 | 105 | 13.28 | 1733 | 2416 | 2.71 / 108.84 | 6 | 7 |
3 | 13 | 1701.68 | 36 | 13.76 | 1561 | 773 | 3.48 / 109.62 | 5 | 11 |
4 | 13 | 1267.48 | 36 | 13.91 | 1294 | 648 | 4.13 / 110.27 | 5 | 16 |
5 | 13 | 715.76 | 36 | 14.16 | 888 | 453 | 4.58 / 110.72 | 5 | 20 |
6 | 13 | 55.28 | 36 | 14.65 | 340 | 179 | 4.76 / 110.90 | 5 | 9 |
7 | 8 | -0.20 | 450 | 14.35 | 280 | 1808 | 6.57 / 112.71 | 5 | 37 |
Average= | 5.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.76 | 57 | 14.69 | 336 | 281 | 0.28 / 99.73 | 6 | 6 |
2 | 7 | 2009.96 | 106 | 13.28 | 1739 | 2448 | 2.73 / 102.18 | 6 | 7 |
3 | 13 | 1575.52 | 36 | 13.80 | 1482 | 736 | 3.47 / 102.92 | 5 | 12 |
4 | 13 | 1248.56 | 36 | 13.93 | 1265 | 634 | 4.10 / 103.55 | 5 | 16 |
5 | 13 | 713.68 | 36 | 14.17 | 877 | 447 | 4.55 / 104.00 | 5 | 20 |
6 | 13 | 49.64 | 36 | 14.65 | 336 | 177 | 4.72 / 104.18 | 5 | 10 |
7 | 13 | 12.52 | 36 | 14.62 | 301 | 158 | 4.88 / 104.33 | 5 | 11 |
8 | 8 | 0.00 | 450 | 14.31 | 280 | 1803 | 6.69 / 106.14 | 5 | 54 |
Average= | 5.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.00 | 57 | 14.69 | 331 | 277 | 0.28 / 93.47 | 6 | 6 |
2 | 7 | 2004.80 | 105 | 13.31 | 1730 | 2418 | 2.69 / 95.88 | 6 | 7 |
3 | 13 | 1566.92 | 36 | 13.82 | 1473 | 733 | 3.43 / 96.62 | 5 | 11 |
4 | 13 | 1037.96 | 36 | 14.02 | 1113 | 562 | 3.99 / 97.18 | 5 | 18 |
5 | 13 | 391.76 | 36 | 14.38 | 618 | 320 | 4.31 / 97.50 | 5 | 17 |
6 | 13 | 39.84 | 36 | 14.69 | 322 | 170 | 4.48 / 97.67 | 5 | 9 |
7 | 8 | -0.24 | 450 | 14.35 | 276 | 1782 | 6.26 / 99.45 | 5 | 34 |
Average= | 5.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.76 | 57 | 14.72 | 332 | 279 | 0.28 / 87.17 | 6 | 6 |
2 | 7 | 2010.68 | 105 | 13.33 | 1738 | 2433 | 2.71 / 89.60 | 6 | 7 |
3 | 13 | 1915.12 | 36 | 13.65 | 1690 | 830 | 3.54 / 90.43 | 5 | 9 |
4 | 13 | 932.68 | 36 | 14.07 | 1036 | 525 | 4.07 / 90.95 | 5 | 18 |
5 | 13 | 396.00 | 36 | 14.39 | 616 | 319 | 4.39 / 91.27 | 5 | 16 |
6 | 13 | 17.36 | 36 | 14.73 | 297 | 157 | 4.54 / 91.43 | 5 | 8 |
7 | 8 | -0.32 | 450 | 14.38 | 272 | 1760 | 6.30 / 93.19 | 5 | 27 |
Average= | 5.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.12 | 57 | 14.75 | 333 | 280 | 0.28 / 80.76 | 6 | 6 |
2 | 3 | 1018.24 | 1 | 14.71 | 1116 | 16 | 0.30 / 80.78 | 5 | 5 |
3 | 7 | 2006.36 | 106 | 13.34 | 1735 | 2453 | 2.75 / 83.23 | 5 | 7 |
4 | 13 | 1573.88 | 36 | 13.84 | 1474 | 734 | 3.48 / 83.97 | 5 | 11 |
5 | 13 | 1155.28 | 36 | 13.99 | 1199 | 604 | 4.09 / 84.57 | 5 | 16 |
6 | 13 | 500.48 | 36 | 14.32 | 703 | 362 | 4.45 / 84.93 | 5 | 17 |
7 | 13 | 36.72 | 36 | 14.71 | 318 | 168 | 4.62 / 85.10 | 5 | 8 |
8 | 8 | -0.04 | 450 | 14.36 | 276 | 1784 | 6.40 / 86.89 | 5 | 33 |
Average= | 5.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.80 | 60 | 14.73 | 336 | 297 | 0.30 / 74.32 | 6 | 6 |
2 | 3 | 962.84 | -1 | 14.73 | 336 | 0 | 0.00 / 74.32 | 6 | 6 |
3 | 7 | 2005.44 | 105 | 13.35 | 1733 | 2429 | 2.73 / 76.75 | 6 | 6 |
4 | 13 | 1688.12 | 36 | 13.80 | 1559 | 775 | 3.50 / 77.52 | 5 | 10 |
5 | 13 | 1065.68 | 36 | 14.02 | 1135 | 573 | 4.07 / 78.10 | 5 | 16 |
6 | 13 | 749.68 | 36 | 14.17 | 902 | 460 | 4.53 / 78.56 | 5 | 18 |
7 | 13 | 35.52 | 36 | 14.74 | 312 | 166 | 4.70 / 78.72 | 5 | 7 |
8 | 8 | -0.08 | 450 | 14.39 | 272 | 1761 | 6.46 / 80.48 | 5 | 29 |
Average= | 5.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.64 | 60 | 14.75 | 329 | 291 | 0.29 / 67.56 | 6 | 6 |
2 | 7 | 2009.72 | 105 | 13.37 | 1741 | 2444 | 2.74 / 70.01 | 6 | 6 |
3 | 13 | 1918.12 | 36 | 13.68 | 1694 | 834 | 3.57 / 70.84 | 5 | 8 |
4 | 13 | 1351.08 | 36 | 13.92 | 1331 | 667 | 4.24 / 71.51 | 5 | 13 |
5 | 13 | 670.64 | 36 | 14.21 | 849 | 434 | 4.67 / 71.94 | 5 | 18 |
6 | 13 | 40.52 | 36 | 14.74 | 320 | 170 | 4.84 / 72.11 | 5 | 8 |
7 | 13 | 20.80 | 36 | 14.63 | 300 | 158 | 5.00 / 72.27 | 5 | 8 |
8 | 8 | -0.24 | 450 | 14.38 | 271 | 1754 | 6.75 / 74.02 | 5 | 38 |
Average= | 5.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.92 | 60 | 14.74 | 335 | 296 | 0.30 / 61.02 | 6 | 6 |
2 | 7 | 2013.44 | 105 | 13.38 | 1736 | 2439 | 2.74 / 63.46 | 6 | 6 |
3 | 13 | 1794.20 | 36 | 13.78 | 1612 | 800 | 3.53 / 64.26 | 5 | 8 |
4 | 13 | 1341.84 | 36 | 13.93 | 1318 | 661 | 4.20 / 64.92 | 5 | 12 |
5 | 13 | 654.12 | 36 | 14.23 | 831 | 426 | 4.62 / 65.35 | 5 | 17 |
6 | 13 | 40.80 | 36 | 14.74 | 318 | 169 | 4.79 / 65.52 | 5 | 8 |
7 | 8 | -0.36 | 450 | 14.38 | 271 | 1754 | 6.54 / 67.27 | 5 | 28 |
Average= | 5.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.60 | 59 | 14.74 | 331 | 288 | 0.29 / 54.73 | 6 | 6 |
2 | 7 | 2008.96 | 106 | 13.39 | 1727 | 2451 | 2.74 / 57.18 | 5 | 6 |
3 | 13 | 1702.20 | 36 | 13.82 | 1552 | 772 | 3.51 / 57.95 | 5 | 8 |
4 | 13 | 1150.32 | 36 | 14.00 | 1182 | 596 | 4.11 / 58.55 | 5 | 13 |
5 | 13 | 385.08 | 36 | 14.43 | 599 | 311 | 4.42 / 58.86 | 5 | 12 |
6 | 13 | 18.20 | 36 | 14.77 | 288 | 153 | 4.57 / 59.01 | 5 | 6 |
7 | 8 | -0.16 | 450 | 14.40 | 265 | 1717 | 6.29 / 60.73 | 5 | 25 |
Average= | 5.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.20 | 62 | 14.75 | 321 | 294 | 0.29 / 48.47 | 6 | 6 |
2 | 3 | 954.08 | -1 | 14.75 | 321 | 0 | 0.00 / 48.47 | 6 | 6 |
3 | 7 | 2023.60 | 106 | 13.39 | 1730 | 2455 | 2.75 / 50.93 | 6 | 6 |
4 | 13 | 1606.04 | 36 | 13.85 | 1476 | 736 | 3.48 / 51.67 | 5 | 8 |
5 | 13 | 1094.12 | 36 | 14.02 | 1136 | 573 | 4.06 / 52.24 | 5 | 12 |
6 | 13 | 441.52 | 36 | 14.39 | 641 | 332 | 4.39 / 52.57 | 5 | 11 |
7 | 13 | 42.76 | 36 | 14.74 | 312 | 166 | 4.56 / 52.74 | 5 | 6 |
8 | 8 | -0.28 | 450 | 14.38 | 263 | 1702 | 6.26 / 54.44 | 5 | 30 |
Average= | 5.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.32 | 62 | 14.76 | 322 | 295 | 0.29 / 42.25 | 6 | 6 |
2 | 7 | 2004.96 | 105 | 13.40 | 1723 | 2424 | 2.72 / 44.67 | 6 | 5 |
3 | 13 | 1593.60 | 36 | 13.85 | 1475 | 735 | 3.45 / 45.41 | 5 | 6 |
4 | 13 | 1040.00 | 36 | 14.04 | 1101 | 556 | 4.01 / 45.97 | 5 | 9 |
5 | 13 | 504.72 | 36 | 14.34 | 693 | 358 | 4.37 / 46.32 | 5 | 9 |
6 | 13 | 33.00 | 36 | 14.77 | 302 | 161 | 4.53 / 46.48 | 5 | 6 |
7 | 8 | -0.20 | 450 | 14.39 | 262 | 1697 | 6.23 / 48.18 | 5 | 22 |
Average= | 5.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.92 | 62 | 14.73 | 318 | 290 | 0.29 / 35.98 | 6 | 6 |
2 | 7 | 2012.40 | 105 | 13.38 | 1729 | 2429 | 2.72 / 38.41 | 6 | 28 |
3 | 13 | 1501.48 | 36 | 13.85 | 1416 | 706 | 3.43 / 39.11 | 5 | 35 |
4 | 13 | 1088.96 | 36 | 14.01 | 1137 | 573 | 4.00 / 39.68 | 5 | 41 |
5 | 13 | 626.04 | 36 | 14.24 | 799 | 410 | 4.41 / 40.09 | 5 | 43 |
6 | 13 | 16.68 | 36 | 14.78 | 289 | 154 | 4.56 / 40.25 | 5 | 27 |
7 | 8 | -0.16 | 450 | 14.37 | 264 | 1707 | 6.27 / 41.96 | 5 | 55 |
Average= | 5.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.64 | 62 | 14.73 | 325 | 297 | 0.30 / 29.76 | 6 | 6 |
2 | 7 | 2007.68 | 105 | 13.37 | 1724 | 2420 | 2.72 / 32.18 | 5 | 28 |
3 | 13 | 1687.88 | 36 | 13.81 | 1538 | 765 | 3.48 / 32.94 | 5 | 33 |
4 | 13 | 942.52 | 36 | 14.06 | 1034 | 523 | 4.01 / 33.47 | 5 | 42 |
5 | 13 | 521.60 | 36 | 14.31 | 709 | 365 | 4.37 / 33.83 | 5 | 44 |
6 | 13 | 35.16 | 36 | 14.74 | 304 | 161 | 4.53 / 33.99 | 5 | 31 |
7 | 8 | -0.16 | 450 | 14.36 | 262 | 1693 | 6.22 / 35.69 | 5 | 61 |
Average= | 5.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.44 | 38 | 14.86 | 329 | 186 | 0.19 / 23.26 | 6 | 6 |
2 | 10 | 1032.92 | 9 | 14.74 | 1080 | 143 | 0.33 / 23.40 | 5 | 18 |
3 | 10 | 1082.88 | 9 | 14.60 | 1107 | 145 | 0.47 / 23.55 | 5 | 20 |
4 | 3 | 1111.76 | 5 | 14.73 | 1156 | 85 | 0.56 / 23.63 | 5 | 34 |
5 | 7 | 2013.80 | 105 | 13.35 | 1728 | 2422 | 2.98 / 26.06 | 34 | 27 |
6 | 13 | 1706.96 | 36 | 13.80 | 1541 | 766 | 3.75 / 26.82 | 5 | 33 |
7 | 13 | 1049.16 | 36 | 14.02 | 1097 | 554 | 4.30 / 27.38 | 5 | 41 |
8 | 13 | 308.56 | 36 | 14.50 | 521 | 272 | 4.57 / 27.65 | 5 | 37 |
9 | 13 | 7.40 | 36 | 14.79 | 272 | 145 | 4.72 / 27.79 | 5 | 27 |
10 | 8 | -0.08 | 450 | 14.37 | 258 | 1668 | 6.39 / 29.46 | 5 | 61 |
Average= | 4.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.24 | 64 | 14.68 | 324 | 304 | 0.30 / 18.06 | 5 | 6 |
2 | 3 | 949.40 | -1 | 14.68 | 324 | 0 | 0.00 / 18.06 | 5 | 6 |
3 | 7 | 1416.20 | 105 | 13.60 | 1329 | 1898 | 2.20 / 19.96 | 6 | 32 |
4 | 13 | 1330.52 | 36 | 13.86 | 1278 | 638 | 2.84 / 20.59 | 5 | 33 |
5 | 13 | 814.00 | 36 | 14.12 | 928 | 472 | 3.31 / 21.07 | 5 | 41 |
6 | 13 | 86.92 | 36 | 14.71 | 339 | 180 | 3.49 / 21.24 | 5 | 30 |
7 | 13 | 21.20 | 36 | 14.71 | 286 | 151 | 3.64 / 21.40 | 5 | 29 |
8 | 8 | 0.00 | 450 | 14.35 | 260 | 1679 | 5.32 / 23.08 | 5 | 63 |
Average= | 4.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.92 | 64 | 14.65 | 333 | 312 | 0.31 / 12.69 | 5 | 6 |
2 | 7 | 1441.48 | 105 | 13.56 | 1347 | 1918 | 2.23 / 14.61 | 6 | 29 |
3 | 13 | 1357.32 | 36 | 13.83 | 1296 | 645 | 2.88 / 15.25 | 5 | 33 |
4 | 13 | 947.56 | 36 | 14.05 | 1021 | 516 | 3.39 / 15.77 | 5 | 40 |
5 | 13 | 368.96 | 36 | 14.41 | 574 | 298 | 3.69 / 16.07 | 5 | 40 |
6 | 8 | 0.00 | 450 | 14.35 | 261 | 1685 | 5.37 / 17.75 | 5 | 58 |
Average= | 4.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.16 | 38 | 14.75 | 334 | 187 | 0.19 / 6.57 | 6 | 6 |
2 | 10 | 1063.60 | 12 | 14.57 | 1095 | 191 | 0.38 / 6.76 | 5 | 19 |
3 | 10 | 1107.68 | 8 | 14.50 | 1131 | 131 | 0.51 / 6.89 | 5 | 20 |
4 | 3 | 1127.68 | 6 | 14.63 | 1163 | 102 | 0.61 / 6.99 | 5 | 34 |
5 | 7 | 1519.44 | 105 | 13.47 | 1394 | 1972 | 2.58 / 8.97 | 34 | 30 |
6 | 13 | 1434.00 | 36 | 13.77 | 1350 | 669 | 3.25 / 9.64 | 5 | 33 |
7 | 13 | 1011.20 | 36 | 13.99 | 1066 | 537 | 3.79 / 10.17 | 5 | 40 |
8 | 13 | 555.80 | 36 | 14.22 | 726 | 372 | 4.16 / 10.54 | 5 | 41 |
9 | 13 | 13.84 | 36 | 14.71 | 285 | 151 | 4.31 / 10.70 | 5 | 33 |
10 | 8 | -0.04 | 450 | 14.28 | 262 | 1684 | 6.00 / 12.38 | 5 | 58 |
Average= | 4.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.32 | 38 | 14.74 | 315 | 176 | 0.18 / 2.58 | 6 | 6 |
2 | 10 | 1026.20 | 13 | 14.41 | 1061 | 199 | 0.38 / 2.77 | 5 | 14 |
3 | 10 | 1065.32 | 7 | 14.38 | 1100 | 111 | 0.49 / 2.88 | 5 | 17 |
4 | 3 | 1105.32 | 5 | 14.42 | 1134 | 82 | 0.57 / 2.97 | 5 | 21 |
5 | 7 | 1067.84 | 105 | 13.60 | 1083 | 1547 | 2.11 / 4.51 | 21 | 29 |
6 | 13 | 148.72 | 36 | 14.51 | 391 | 204 | 2.32 / 4.72 | 5 | 31 |
7 | 8 | -0.04 | 450 | 14.29 | 259 | 1665 | 3.98 / 6.38 | 5 | 52 |
Average= | 3.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 128.96 | 38 | 14.48 | 323 | 178 | 0.18 / 0.18 | 6 | 6 |
2 | 7 | 140.28 | 105 | 14.34 | 325 | 489 | 0.67 / 0.67 | 6 | 6 |
3 | 13 | 83.68 | 36 | 14.68 | 291 | 154 | 0.82 / 0.82 | 6 | 6 |
4 | 13 | 21.24 | 36 | 14.72 | 248 | 131 | 0.95 / 0.95 | 6 | 7 |
5 | 8 | 0.12 | 450 | 14.48 | 222 | 1447 | 2.40 / 2.40 | 6 | 37 |
Average= | 2.40 (KJ/cycle) |