SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.64 | 85 | 10.63 | 333 | 301 | 0.30 / 1895.07 | 6 | 6 |
2 | 3 | 1010.84 | 1 | 8.53 | 1058 | 9 | 0.31 / 1895.08 | 5 | 5 |
3 | 7 | 2008.00 | 105 | 6.42 | 1738 | 1172 | 1.48 / 1896.25 | 5 | 5 |
4 | 13 | 1971.72 | 36 | 6.53 | 1721 | 405 | 1.89 / 1896.65 | 5 | 5 |
5 | 13 | 1914.04 | 36 | 6.68 | 1669 | 401 | 2.29 / 1897.06 | 5 | 6 |
6 | 13 | 1843.80 | 36 | 6.80 | 1632 | 400 | 2.69 / 1897.46 | 5 | 6 |
7 | 13 | 1766.28 | 36 | 6.88 | 1566 | 388 | 3.07 / 1897.84 | 5 | 7 |
8 | 13 | 1673.72 | 36 | 7.03 | 1509 | 382 | 3.46 / 1898.23 | 5 | 7 |
9 | 13 | 1386.72 | 36 | 7.56 | 1313 | 357 | 3.81 / 1898.58 | 5 | 10 |
10 | 13 | 1290.00 | 36 | 7.72 | 1247 | 347 | 4.16 / 1898.93 | 5 | 12 |
11 | 13 | 884.60 | 36 | 8.43 | 974 | 296 | 4.46 / 1899.22 | 5 | 18 |
12 | 13 | 575.36 | 36 | 9.07 | 739 | 241 | 4.70 / 1899.47 | 5 | 24 |
13 | 13 | 160.44 | 36 | 10.15 | 403 | 147 | 4.84 / 1899.61 | 6 | 24 |
14 | 8 | -0.16 | 435 | 10.65 | 255 | 1181 | 6.03 / 1900.79 | 6 | 36 |
Average= | 21.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.56 | 85 | 10.70 | 317 | 288 | 0.29 / 1889.02 | 6 | 6 |
2 | 7 | 2012.16 | 105 | 6.55 | 1747 | 1201 | 1.49 / 1890.22 | 5 | 5 |
3 | 13 | 1976.28 | 36 | 6.74 | 1721 | 418 | 1.91 / 1890.64 | 5 | 5 |
4 | 13 | 1918.80 | 36 | 6.83 | 1685 | 414 | 2.32 / 1891.05 | 5 | 6 |
5 | 13 | 1841.60 | 36 | 6.93 | 1626 | 406 | 2.73 / 1891.46 | 5 | 6 |
6 | 13 | 1749.32 | 36 | 7.06 | 1562 | 397 | 3.12 / 1891.86 | 5 | 7 |
7 | 13 | 1560.12 | 36 | 7.38 | 1440 | 383 | 3.51 / 1892.24 | 5 | 9 |
8 | 13 | 1265.04 | 36 | 7.90 | 1233 | 351 | 3.86 / 1892.59 | 5 | 12 |
9 | 13 | 1064.08 | 36 | 8.24 | 1097 | 325 | 4.18 / 1892.91 | 5 | 15 |
10 | 13 | 871.80 | 36 | 8.57 | 961 | 296 | 4.48 / 1893.21 | 5 | 19 |
11 | 13 | 449.28 | 36 | 9.46 | 645 | 220 | 4.70 / 1893.43 | 5 | 25 |
12 | 13 | 66.24 | 36 | 10.47 | 316 | 119 | 4.82 / 1893.55 | 6 | 20 |
13 | 8 | -0.28 | 435 | 10.66 | 263 | 1220 | 6.04 / 1894.77 | 6 | 35 |
Average= | 21.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.44 | 85 | 10.69 | 324 | 294 | 0.29 / 1883.04 | 6 | 6 |
2 | 7 | 2005.96 | 105 | 6.68 | 1748 | 1226 | 1.52 / 1884.26 | 6 | 5 |
3 | 13 | 1962.44 | 36 | 6.88 | 1718 | 426 | 1.95 / 1884.69 | 5 | 5 |
4 | 13 | 1896.00 | 36 | 6.98 | 1672 | 420 | 2.37 / 1885.11 | 5 | 6 |
5 | 13 | 1817.64 | 36 | 7.15 | 1607 | 414 | 2.78 / 1885.52 | 5 | 7 |
6 | 13 | 1631.52 | 36 | 7.41 | 1487 | 397 | 3.18 / 1885.92 | 5 | 8 |
7 | 13 | 1535.04 | 36 | 7.56 | 1414 | 385 | 3.56 / 1886.30 | 5 | 9 |
8 | 13 | 1330.28 | 36 | 7.91 | 1279 | 364 | 3.93 / 1886.67 | 5 | 13 |
9 | 13 | 1026.20 | 36 | 8.40 | 1070 | 324 | 4.25 / 1886.99 | 5 | 16 |
10 | 13 | 713.92 | 36 | 8.95 | 850 | 274 | 4.52 / 1887.26 | 5 | 22 |
11 | 13 | 294.64 | 36 | 9.92 | 514 | 184 | 4.71 / 1887.45 | 5 | 26 |
12 | 13 | 23.08 | 36 | 10.63 | 272 | 104 | 4.81 / 1887.55 | 6 | 18 |
13 | 8 | -0.16 | 435 | 10.71 | 253 | 1179 | 5.99 / 1888.73 | 6 | 32 |
Average= | 21.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.88 | 85 | 10.72 | 324 | 295 | 0.30 / 1876.97 | 6 | 6 |
2 | 7 | 2004.40 | 105 | 6.82 | 1748 | 1252 | 1.55 / 1878.22 | 6 | 5 |
3 | 13 | 1959.44 | 36 | 7.02 | 1710 | 432 | 1.98 / 1878.65 | 5 | 6 |
4 | 13 | 1891.80 | 36 | 7.11 | 1672 | 428 | 2.41 / 1879.08 | 5 | 6 |
5 | 13 | 1808.92 | 36 | 7.24 | 1615 | 421 | 2.83 / 1879.50 | 5 | 7 |
6 | 13 | 1715.84 | 36 | 7.40 | 1548 | 412 | 3.24 / 1879.91 | 5 | 8 |
7 | 13 | 1618.88 | 36 | 7.55 | 1482 | 403 | 3.64 / 1880.31 | 5 | 9 |
8 | 13 | 1215.04 | 36 | 8.19 | 1205 | 355 | 4.00 / 1880.67 | 5 | 14 |
9 | 13 | 1118.24 | 36 | 8.35 | 1140 | 343 | 4.34 / 1881.01 | 5 | 16 |
10 | 13 | 797.60 | 36 | 8.88 | 913 | 292 | 4.63 / 1881.30 | 5 | 22 |
11 | 13 | 365.72 | 36 | 9.79 | 574 | 202 | 4.84 / 1881.51 | 5 | 27 |
12 | 8 | -0.04 | 450 | 10.73 | 256 | 1236 | 6.07 / 1882.74 | 6 | 33 |
Average= | 22.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.68 | 85 | 10.72 | 322 | 293 | 0.29 / 1871.00 | 6 | 6 |
2 | 7 | 2004.36 | 105 | 6.92 | 1751 | 1272 | 1.57 / 1872.27 | 6 | 6 |
3 | 13 | 1955.60 | 36 | 7.10 | 1719 | 439 | 2.01 / 1872.71 | 5 | 6 |
4 | 13 | 1884.04 | 36 | 7.23 | 1664 | 433 | 2.44 / 1873.14 | 5 | 7 |
5 | 13 | 1799.56 | 36 | 7.34 | 1610 | 425 | 2.86 / 1873.57 | 5 | 8 |
6 | 13 | 1709.00 | 36 | 7.52 | 1544 | 418 | 3.28 / 1873.98 | 5 | 8 |
7 | 13 | 1611.80 | 36 | 7.66 | 1474 | 406 | 3.69 / 1874.39 | 5 | 10 |
8 | 13 | 1201.80 | 36 | 8.30 | 1199 | 358 | 4.05 / 1874.75 | 5 | 15 |
9 | 13 | 907.60 | 36 | 8.77 | 995 | 314 | 4.36 / 1875.06 | 5 | 20 |
10 | 13 | 505.40 | 36 | 9.51 | 697 | 239 | 4.60 / 1875.30 | 5 | 26 |
11 | 13 | 103.04 | 36 | 10.49 | 344 | 130 | 4.73 / 1875.43 | 6 | 21 |
12 | 8 | -0.08 | 450 | 10.75 | 256 | 1238 | 5.97 / 1876.67 | 6 | 30 |
Average= | 22.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.12 | 85 | 10.72 | 332 | 303 | 0.30 / 1865.00 | 6 | 6 |
2 | 7 | 2011.52 | 105 | 7.02 | 1757 | 1295 | 1.60 / 1866.30 | 5 | 6 |
3 | 13 | 1952.04 | 36 | 7.20 | 1712 | 444 | 2.04 / 1866.74 | 5 | 6 |
4 | 13 | 1876.52 | 36 | 7.33 | 1666 | 440 | 2.48 / 1867.18 | 5 | 7 |
5 | 13 | 1795.04 | 36 | 7.49 | 1605 | 433 | 2.91 / 1867.62 | 5 | 8 |
6 | 13 | 1706.16 | 36 | 7.59 | 1545 | 422 | 3.34 / 1868.04 | 5 | 9 |
7 | 13 | 1403.00 | 36 | 8.08 | 1336 | 389 | 3.72 / 1868.43 | 5 | 13 |
8 | 13 | 1203.84 | 36 | 8.37 | 1206 | 363 | 4.09 / 1868.79 | 5 | 16 |
9 | 13 | 892.24 | 36 | 8.86 | 981 | 313 | 4.40 / 1869.10 | 5 | 20 |
10 | 13 | 577.00 | 36 | 9.41 | 751 | 254 | 4.66 / 1869.36 | 5 | 26 |
11 | 13 | 74.96 | 36 | 10.59 | 314 | 120 | 4.77 / 1869.48 | 6 | 20 |
12 | 8 | -0.12 | 450 | 10.77 | 253 | 1226 | 6.00 / 1870.70 | 6 | 37 |
Average= | 22.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.24 | 85 | 10.76 | 327 | 299 | 0.30 / 1858.96 | 6 | 6 |
2 | 7 | 2014.56 | 105 | 7.13 | 1761 | 1318 | 1.62 / 1860.27 | 6 | 6 |
3 | 13 | 1962.40 | 36 | 7.33 | 1725 | 455 | 2.07 / 1860.73 | 5 | 6 |
4 | 13 | 1887.84 | 36 | 7.45 | 1670 | 448 | 2.52 / 1861.18 | 5 | 7 |
5 | 13 | 1802.56 | 36 | 7.57 | 1616 | 440 | 2.96 / 1861.62 | 5 | 8 |
6 | 13 | 1706.80 | 36 | 7.74 | 1546 | 431 | 3.39 / 1862.05 | 5 | 9 |
7 | 13 | 1506.96 | 36 | 8.04 | 1408 | 408 | 3.80 / 1862.46 | 5 | 11 |
8 | 13 | 1185.68 | 36 | 8.50 | 1190 | 364 | 4.16 / 1862.82 | 5 | 16 |
9 | 13 | 778.32 | 36 | 9.11 | 902 | 296 | 4.46 / 1863.12 | 5 | 22 |
10 | 13 | 379.84 | 36 | 9.90 | 586 | 209 | 4.67 / 1863.33 | 5 | 26 |
11 | 13 | 84.72 | 36 | 10.57 | 331 | 126 | 4.79 / 1863.45 | 6 | 21 |
12 | 8 | -0.08 | 450 | 10.77 | 258 | 1250 | 6.04 / 1864.70 | 6 | 42 |
Average= | 22.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.68 | 85 | 10.75 | 326 | 298 | 0.30 / 1852.95 | 6 | 6 |
2 | 7 | 2011.64 | 106 | 7.24 | 1753 | 1345 | 1.64 / 1854.29 | 6 | 6 |
3 | 13 | 1954.76 | 36 | 7.43 | 1722 | 461 | 2.10 / 1854.75 | 5 | 6 |
4 | 13 | 1883.76 | 36 | 7.53 | 1671 | 453 | 2.56 / 1855.21 | 5 | 7 |
5 | 13 | 1795.72 | 36 | 7.66 | 1610 | 444 | 3.00 / 1855.65 | 5 | 8 |
6 | 13 | 1593.00 | 36 | 8.00 | 1469 | 423 | 3.42 / 1856.07 | 5 | 11 |
7 | 13 | 1299.88 | 36 | 8.40 | 1271 | 384 | 3.81 / 1856.46 | 5 | 15 |
8 | 13 | 1005.20 | 36 | 8.83 | 1065 | 339 | 4.15 / 1856.80 | 5 | 19 |
9 | 13 | 708.20 | 36 | 9.28 | 853 | 285 | 4.43 / 1857.08 | 5 | 24 |
10 | 13 | 297.68 | 36 | 10.11 | 520 | 189 | 4.62 / 1857.27 | 5 | 26 |
11 | 13 | 94.28 | 36 | 10.57 | 340 | 129 | 4.75 / 1857.40 | 6 | 22 |
12 | 8 | -0.16 | 450 | 10.78 | 259 | 1256 | 6.01 / 1858.66 | 6 | 34 |
Average= | 22.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.28 | 85 | 10.77 | 328 | 300 | 0.30 / 1846.81 | 6 | 6 |
2 | 7 | 2015.76 | 106 | 7.33 | 1767 | 1373 | 1.67 / 1848.18 | 6 | 6 |
3 | 13 | 1957.32 | 36 | 7.51 | 1733 | 469 | 2.14 / 1848.65 | 5 | 7 |
4 | 13 | 1878.24 | 36 | 7.69 | 1669 | 462 | 2.60 / 1849.11 | 5 | 8 |
5 | 13 | 1786.16 | 36 | 7.79 | 1607 | 451 | 3.05 / 1849.56 | 5 | 9 |
6 | 13 | 1687.28 | 36 | 7.92 | 1540 | 439 | 3.49 / 1850.00 | 5 | 10 |
7 | 13 | 1588.64 | 36 | 8.08 | 1466 | 426 | 3.92 / 1850.43 | 5 | 12 |
8 | 13 | 1159.44 | 36 | 8.69 | 1171 | 366 | 4.29 / 1850.79 | 5 | 17 |
9 | 13 | 842.44 | 36 | 9.14 | 953 | 314 | 4.60 / 1851.11 | 5 | 22 |
10 | 13 | 322.52 | 36 | 10.08 | 544 | 197 | 4.80 / 1851.30 | 5 | 27 |
11 | 13 | 12.48 | 36 | 10.77 | 264 | 102 | 4.90 / 1851.41 | 6 | 18 |
12 | 8 | -0.08 | 450 | 10.80 | 256 | 1244 | 6.14 / 1852.65 | 6 | 34 |
Average= | 23.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.48 | 85 | 10.79 | 330 | 303 | 0.30 / 1840.84 | 6 | 6 |
2 | 7 | 2006.88 | 105 | 7.42 | 1760 | 1371 | 1.67 / 1842.21 | 5 | 6 |
3 | 13 | 1957.84 | 36 | 7.60 | 1728 | 473 | 2.15 / 1842.68 | 5 | 7 |
4 | 13 | 1886.52 | 36 | 7.70 | 1677 | 465 | 2.61 / 1843.15 | 5 | 8 |
5 | 13 | 1800.16 | 36 | 7.88 | 1616 | 458 | 3.07 / 1843.61 | 5 | 9 |
6 | 13 | 1607.12 | 36 | 8.11 | 1484 | 433 | 3.50 / 1844.04 | 5 | 11 |
7 | 13 | 1301.72 | 36 | 8.58 | 1272 | 393 | 3.90 / 1844.43 | 5 | 15 |
8 | 13 | 998.60 | 36 | 8.96 | 1066 | 344 | 4.24 / 1844.78 | 5 | 21 |
9 | 13 | 690.80 | 36 | 9.43 | 844 | 287 | 4.53 / 1845.06 | 5 | 26 |
10 | 13 | 270.00 | 36 | 10.22 | 499 | 184 | 4.71 / 1845.25 | 5 | 26 |
11 | 8 | -0.16 | 450 | 10.81 | 259 | 1260 | 5.97 / 1846.51 | 6 | 38 |
Average= | 23.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.52 | 85 | 10.81 | 327 | 300 | 0.30 / 1834.69 | 6 | 6 |
2 | 7 | 2025.16 | 105 | 7.49 | 1777 | 1398 | 1.70 / 1836.09 | 5 | 6 |
3 | 13 | 1995.24 | 36 | 7.63 | 1758 | 483 | 2.18 / 1836.57 | 5 | 7 |
4 | 13 | 1973.72 | 36 | 7.73 | 1742 | 485 | 2.67 / 1837.06 | 5 | 8 |
5 | 13 | 1882.00 | 36 | 7.85 | 1678 | 474 | 3.14 / 1837.53 | 5 | 9 |
6 | 13 | 1685.08 | 36 | 8.12 | 1535 | 449 | 3.59 / 1837.98 | 5 | 11 |
7 | 13 | 1600.96 | 36 | 8.23 | 1482 | 439 | 4.03 / 1838.42 | 5 | 13 |
8 | 13 | 1175.40 | 36 | 8.81 | 1186 | 376 | 4.40 / 1838.80 | 5 | 19 |
9 | 13 | 665.32 | 36 | 9.54 | 820 | 282 | 4.69 / 1839.08 | 5 | 26 |
10 | 13 | 348.36 | 36 | 10.11 | 564 | 205 | 4.89 / 1839.28 | 5 | 27 |
11 | 8 | -0.04 | 450 | 10.83 | 257 | 1252 | 6.14 / 1840.54 | 6 | 33 |
Average= | 23.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.04 | 85 | 10.83 | 322 | 296 | 0.30 / 1828.63 | 6 | 6 |
2 | 7 | 2018.76 | 105 | 7.56 | 1774 | 1408 | 1.70 / 1830.04 | 6 | 6 |
3 | 13 | 1960.16 | 36 | 7.80 | 1732 | 486 | 2.19 / 1830.52 | 5 | 7 |
4 | 13 | 1879.04 | 36 | 7.98 | 1682 | 483 | 2.67 / 1831.00 | 5 | 8 |
5 | 13 | 1798.64 | 36 | 8.00 | 1628 | 469 | 3.14 / 1831.47 | 5 | 9 |
6 | 13 | 1505.64 | 36 | 8.43 | 1420 | 431 | 3.57 / 1831.90 | 5 | 13 |
7 | 13 | 1413.72 | 36 | 8.56 | 1352 | 417 | 3.99 / 1832.32 | 5 | 15 |
8 | 13 | 1103.40 | 36 | 8.95 | 1139 | 367 | 4.36 / 1832.69 | 5 | 20 |
9 | 13 | 774.52 | 36 | 9.39 | 908 | 307 | 4.66 / 1833.00 | 5 | 25 |
10 | 13 | 136.32 | 36 | 10.57 | 377 | 143 | 4.81 / 1833.14 | 6 | 23 |
11 | 8 | -0.04 | 450 | 10.85 | 257 | 1255 | 6.06 / 1834.39 | 6 | 32 |
Average= | 23.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.36 | 85 | 10.85 | 321 | 296 | 0.30 / 1823.49 | 6 | 6 |
2 | 7 | 1492.80 | 105 | 8.33 | 1402 | 1226 | 1.52 / 1824.71 | 6 | 10 |
3 | 13 | 1478.64 | 36 | 8.49 | 1393 | 426 | 1.95 / 1825.14 | 5 | 11 |
4 | 13 | 1415.72 | 36 | 8.59 | 1350 | 417 | 2.37 / 1825.56 | 5 | 13 |
5 | 13 | 1331.08 | 36 | 8.71 | 1291 | 405 | 2.77 / 1825.96 | 5 | 15 |
6 | 13 | 1235.00 | 36 | 8.84 | 1230 | 391 | 3.16 / 1826.35 | 5 | 17 |
7 | 13 | 1038.60 | 36 | 9.08 | 1089 | 356 | 3.52 / 1826.71 | 5 | 20 |
8 | 13 | 515.44 | 36 | 9.88 | 695 | 247 | 3.76 / 1826.95 | 5 | 28 |
9 | 13 | 105.84 | 36 | 10.65 | 349 | 134 | 3.90 / 1827.09 | 6 | 22 |
10 | 8 | -0.04 | 450 | 10.87 | 254 | 1242 | 5.14 / 1828.33 | 6 | 27 |
Average= | 24.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.84 | 85 | 10.86 | 327 | 302 | 0.30 / 1817.45 | 6 | 6 |
2 | 7 | 2013.88 | 106 | 7.79 | 1769 | 1461 | 1.76 / 1818.91 | 6 | 7 |
3 | 13 | 1961.48 | 36 | 7.96 | 1734 | 497 | 2.26 / 1819.41 | 5 | 8 |
4 | 13 | 1883.68 | 36 | 8.13 | 1687 | 494 | 2.75 / 1819.91 | 5 | 9 |
5 | 13 | 1792.16 | 36 | 8.18 | 1626 | 479 | 3.23 / 1820.38 | 5 | 10 |
6 | 13 | 1593.12 | 36 | 8.49 | 1482 | 453 | 3.69 / 1820.84 | 5 | 13 |
7 | 13 | 1195.16 | 36 | 8.97 | 1207 | 390 | 4.07 / 1821.23 | 5 | 18 |
8 | 13 | 784.52 | 36 | 9.48 | 914 | 312 | 4.39 / 1821.54 | 5 | 23 |
9 | 13 | 572.92 | 36 | 9.81 | 748 | 264 | 4.65 / 1821.80 | 5 | 28 |
10 | 13 | 135.00 | 36 | 10.61 | 374 | 143 | 4.79 / 1821.95 | 6 | 24 |
11 | 8 | -0.08 | 450 | 10.88 | 254 | 1244 | 6.04 / 1823.19 | 6 | 37 |
Average= | 24.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.12 | 85 | 10.90 | 316 | 293 | 0.29 / 1811.40 | 6 | 6 |
2 | 7 | 2004.68 | 106 | 7.85 | 1764 | 1468 | 1.76 / 1812.86 | 6 | 7 |
3 | 13 | 1941.60 | 36 | 8.09 | 1723 | 502 | 2.26 / 1813.36 | 5 | 8 |
4 | 13 | 1850.44 | 36 | 8.18 | 1664 | 490 | 2.75 / 1813.85 | 5 | 10 |
5 | 13 | 1760.60 | 36 | 8.31 | 1598 | 478 | 3.23 / 1814.33 | 5 | 11 |
6 | 13 | 1366.92 | 36 | 8.83 | 1318 | 419 | 3.65 / 1814.75 | 5 | 15 |
7 | 13 | 1274.52 | 36 | 8.91 | 1261 | 404 | 4.05 / 1815.16 | 5 | 18 |
8 | 13 | 749.52 | 36 | 9.57 | 887 | 306 | 4.36 / 1815.46 | 5 | 25 |
9 | 13 | 652.16 | 36 | 9.70 | 815 | 285 | 4.64 / 1815.75 | 5 | 28 |
10 | 13 | 114.80 | 36 | 10.65 | 362 | 139 | 4.78 / 1815.89 | 6 | 24 |
11 | 8 | -0.16 | 450 | 10.87 | 259 | 1267 | 6.05 / 1817.15 | 6 | 44 |
Average= | 24.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.52 | 85 | 10.87 | 330 | 305 | 0.30 / 1805.15 | 6 | 6 |
2 | 7 | 2007.84 | 106 | 7.91 | 1768 | 1482 | 1.79 / 1806.63 | 5 | 7 |
3 | 13 | 1944.68 | 36 | 8.13 | 1727 | 505 | 2.29 / 1807.13 | 5 | 8 |
4 | 13 | 1871.08 | 36 | 8.27 | 1673 | 498 | 2.79 / 1807.63 | 5 | 10 |
5 | 13 | 1777.04 | 36 | 8.35 | 1615 | 485 | 3.28 / 1808.12 | 5 | 11 |
6 | 13 | 1575.00 | 36 | 8.62 | 1472 | 457 | 3.73 / 1808.57 | 5 | 14 |
7 | 13 | 1477.44 | 36 | 8.71 | 1404 | 440 | 4.17 / 1809.01 | 5 | 16 |
8 | 13 | 836.08 | 36 | 9.50 | 956 | 327 | 4.50 / 1809.34 | 5 | 25 |
9 | 13 | 529.64 | 36 | 9.96 | 713 | 256 | 4.76 / 1809.60 | 5 | 28 |
10 | 13 | 96.72 | 36 | 10.68 | 349 | 134 | 4.89 / 1809.73 | 6 | 24 |
11 | 13 | 6.64 | 36 | 10.85 | 265 | 104 | 4.99 / 1809.83 | 6 | 20 |
12 | 8 | -0.28 | 450 | 10.88 | 259 | 1268 | 6.26 / 1811.10 | 6 | 40 |
Average= | 24.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.56 | 84 | 10.90 | 319 | 292 | 0.29 / 1799.01 | 6 | 6 |
2 | 7 | 2004.28 | 105 | 7.98 | 1764 | 1478 | 1.77 / 1800.49 | 5 | 8 |
3 | 13 | 1941.28 | 36 | 8.19 | 1723 | 508 | 2.28 / 1801.00 | 5 | 8 |
4 | 13 | 1858.00 | 36 | 8.32 | 1673 | 501 | 2.78 / 1801.50 | 5 | 10 |
5 | 13 | 1761.28 | 36 | 8.42 | 1608 | 487 | 3.27 / 1801.99 | 5 | 12 |
6 | 13 | 1556.08 | 36 | 8.67 | 1462 | 456 | 3.72 / 1802.44 | 5 | 15 |
7 | 13 | 1236.08 | 36 | 9.07 | 1239 | 405 | 4.13 / 1802.85 | 5 | 18 |
8 | 13 | 817.64 | 36 | 9.57 | 936 | 322 | 4.45 / 1803.17 | 5 | 25 |
9 | 13 | 501.80 | 36 | 10.03 | 692 | 250 | 4.70 / 1803.42 | 5 | 28 |
10 | 13 | 76.44 | 36 | 10.72 | 337 | 130 | 4.83 / 1803.55 | 6 | 24 |
11 | 8 | -0.28 | 450 | 10.87 | 264 | 1291 | 6.12 / 1804.84 | 6 | 37 |
Average= | 25.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.72 | 84 | 10.90 | 326 | 298 | 0.30 / 1792.73 | 6 | 6 |
2 | 7 | 2004.48 | 105 | 8.02 | 1773 | 1493 | 1.79 / 1794.23 | 5 | 8 |
3 | 13 | 1948.12 | 36 | 8.19 | 1737 | 512 | 2.30 / 1794.74 | 5 | 9 |
4 | 13 | 1872.24 | 36 | 8.36 | 1682 | 506 | 2.81 / 1795.24 | 5 | 10 |
5 | 13 | 1779.36 | 36 | 8.49 | 1615 | 494 | 3.30 / 1795.74 | 5 | 11 |
6 | 13 | 1581.92 | 36 | 8.74 | 1475 | 464 | 3.77 / 1796.20 | 5 | 15 |
7 | 13 | 1175.36 | 36 | 9.20 | 1195 | 396 | 4.16 / 1796.60 | 5 | 20 |
8 | 13 | 875.96 | 36 | 9.55 | 977 | 336 | 4.50 / 1796.93 | 5 | 25 |
9 | 13 | 562.56 | 36 | 9.97 | 736 | 264 | 4.76 / 1797.20 | 5 | 29 |
10 | 13 | 55.08 | 36 | 10.78 | 315 | 122 | 4.89 / 1797.32 | 6 | 23 |
11 | 13 | 27.64 | 36 | 10.83 | 289 | 113 | 5.00 / 1797.43 | 6 | 23 |
12 | 8 | -0.40 | 450 | 10.88 | 263 | 1288 | 6.29 / 1798.72 | 6 | 37 |
Average= | 25.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.84 | 84 | 10.92 | 322 | 295 | 0.30 / 1787.71 | 6 | 6 |
2 | 7 | 1291.04 | 106 | 8.86 | 1259 | 1182 | 1.48 / 1788.89 | 5 | 14 |
3 | 13 | 1291.36 | 36 | 8.97 | 1272 | 411 | 1.89 / 1789.30 | 5 | 16 |
4 | 13 | 1257.36 | 36 | 9.05 | 1249 | 407 | 2.30 / 1789.71 | 5 | 17 |
5 | 13 | 1186.72 | 36 | 9.15 | 1197 | 394 | 2.69 / 1790.10 | 5 | 19 |
6 | 13 | 1089.24 | 36 | 9.27 | 1134 | 378 | 3.07 / 1790.48 | 5 | 21 |
7 | 13 | 881.12 | 36 | 9.54 | 977 | 336 | 3.40 / 1790.82 | 5 | 25 |
8 | 13 | 443.48 | 36 | 10.16 | 641 | 234 | 3.64 / 1791.05 | 5 | 29 |
9 | 13 | 56.92 | 36 | 10.80 | 311 | 121 | 3.76 / 1791.17 | 6 | 22 |
10 | 8 | -0.16 | 450 | 10.91 | 257 | 1262 | 5.02 / 1792.43 | 6 | 41 |
Average= | 25.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.80 | 84 | 10.94 | 315 | 289 | 0.29 / 1782.29 | 6 | 6 |
2 | 7 | 1618.88 | 105 | 8.59 | 1494 | 1348 | 1.64 / 1783.63 | 5 | 11 |
3 | 13 | 1593.92 | 36 | 8.74 | 1485 | 467 | 2.10 / 1784.10 | 5 | 12 |
4 | 13 | 1527.84 | 36 | 8.86 | 1443 | 460 | 2.56 / 1784.56 | 5 | 14 |
5 | 13 | 1441.80 | 36 | 8.95 | 1378 | 444 | 3.01 / 1785.01 | 5 | 16 |
6 | 13 | 1343.68 | 36 | 9.09 | 1304 | 427 | 3.44 / 1785.43 | 5 | 18 |
7 | 13 | 930.20 | 36 | 9.54 | 1018 | 350 | 3.78 / 1785.78 | 5 | 24 |
8 | 13 | 512.48 | 36 | 10.09 | 701 | 255 | 4.04 / 1786.04 | 5 | 28 |
9 | 13 | 55.20 | 36 | 10.83 | 304 | 119 | 4.16 / 1786.15 | 6 | 21 |
10 | 8 | -0.20 | 450 | 10.92 | 256 | 1258 | 5.42 / 1787.41 | 6 | 37 |
Average= | 25.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.88 | 84 | 10.94 | 324 | 298 | 0.30 / 1776.67 | 6 | 6 |
2 | 7 | 1718.52 | 106 | 8.54 | 1566 | 1418 | 1.72 / 1778.09 | 6 | 10 |
3 | 13 | 1674.68 | 36 | 8.71 | 1543 | 484 | 2.20 / 1778.57 | 5 | 11 |
4 | 13 | 1606.12 | 36 | 8.82 | 1496 | 475 | 2.67 / 1779.05 | 5 | 14 |
5 | 13 | 1517.48 | 36 | 8.93 | 1435 | 461 | 3.14 / 1779.51 | 5 | 16 |
6 | 13 | 1420.08 | 36 | 9.06 | 1366 | 446 | 3.58 / 1779.96 | 5 | 18 |
7 | 13 | 993.96 | 36 | 9.50 | 1065 | 364 | 3.95 / 1780.32 | 5 | 23 |
8 | 13 | 584.32 | 36 | 10.02 | 758 | 273 | 4.22 / 1780.59 | 5 | 28 |
9 | 13 | 79.16 | 36 | 10.79 | 333 | 129 | 4.35 / 1780.72 | 6 | 23 |
10 | 8 | -0.20 | 450 | 10.93 | 259 | 1274 | 5.62 / 1782.00 | 6 | 32 |
Average= | 26.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.40 | 84 | 10.94 | 325 | 299 | 0.30 / 1770.98 | 6 | 6 |
2 | 7 | 1710.52 | 105 | 8.59 | 1565 | 1412 | 1.71 / 1772.39 | 6 | 10 |
3 | 13 | 1661.80 | 36 | 8.78 | 1535 | 485 | 2.20 / 1772.88 | 5 | 12 |
4 | 13 | 1588.80 | 36 | 8.90 | 1482 | 475 | 2.67 / 1773.35 | 5 | 13 |
5 | 13 | 1499.80 | 36 | 9.02 | 1423 | 462 | 3.13 / 1773.81 | 5 | 15 |
6 | 13 | 1302.72 | 36 | 9.22 | 1280 | 425 | 3.56 / 1774.24 | 5 | 19 |
7 | 13 | 986.76 | 36 | 9.55 | 1062 | 365 | 3.92 / 1774.60 | 5 | 23 |
8 | 13 | 566.24 | 36 | 10.08 | 740 | 269 | 4.19 / 1774.87 | 5 | 29 |
9 | 13 | 67.56 | 36 | 10.83 | 320 | 125 | 4.32 / 1775.00 | 6 | 22 |
10 | 13 | 34.96 | 36 | 10.87 | 291 | 114 | 4.43 / 1775.11 | 6 | 21 |
11 | 8 | -0.20 | 450 | 10.94 | 257 | 1265 | 5.69 / 1776.37 | 6 | 40 |
Average= | 26.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.44 | 84 | 10.96 | 324 | 298 | 0.30 / 1764.86 | 6 | 6 |
2 | 7 | 2004.20 | 105 | 8.35 | 1777 | 1558 | 1.86 / 1766.42 | 5 | 8 |
3 | 13 | 1937.20 | 36 | 8.57 | 1733 | 535 | 2.39 / 1766.96 | 5 | 10 |
4 | 13 | 1847.44 | 36 | 8.70 | 1669 | 523 | 2.91 / 1767.48 | 5 | 12 |
5 | 13 | 1753.32 | 36 | 8.80 | 1609 | 510 | 3.42 / 1767.99 | 5 | 14 |
6 | 13 | 1450.36 | 36 | 9.15 | 1383 | 456 | 3.88 / 1768.44 | 5 | 17 |
7 | 13 | 1041.28 | 36 | 9.55 | 1101 | 379 | 4.26 / 1768.82 | 5 | 23 |
8 | 13 | 737.56 | 36 | 9.89 | 877 | 312 | 4.57 / 1769.14 | 5 | 27 |
9 | 13 | 195.44 | 36 | 10.64 | 434 | 166 | 4.74 / 1769.30 | 6 | 25 |
10 | 13 | 41.72 | 36 | 10.88 | 298 | 117 | 4.85 / 1769.42 | 6 | 22 |
11 | 8 | -0.16 | 450 | 10.95 | 256 | 1261 | 6.11 / 1770.68 | 6 | 41 |
Average= | 26.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.04 | 84 | 10.96 | 324 | 298 | 0.30 / 1758.80 | 6 | 6 |
2 | 7 | 2005.96 | 105 | 8.43 | 1779 | 1575 | 1.87 / 1760.38 | 6 | 8 |
3 | 13 | 1939.28 | 36 | 8.64 | 1734 | 539 | 2.41 / 1760.92 | 5 | 10 |
4 | 13 | 1855.56 | 36 | 8.76 | 1675 | 528 | 2.94 / 1761.45 | 5 | 12 |
5 | 13 | 1760.52 | 36 | 8.85 | 1606 | 512 | 3.45 / 1761.96 | 5 | 14 |
6 | 13 | 1352.24 | 36 | 9.28 | 1321 | 441 | 3.89 / 1762.40 | 5 | 18 |
7 | 13 | 1044.16 | 36 | 9.57 | 1104 | 380 | 4.27 / 1762.78 | 5 | 23 |
8 | 13 | 632.68 | 36 | 10.06 | 792 | 287 | 4.56 / 1763.07 | 5 | 28 |
9 | 13 | 110.92 | 36 | 10.80 | 352 | 137 | 4.70 / 1763.20 | 6 | 23 |
10 | 13 | 28.16 | 36 | 10.91 | 283 | 111 | 4.81 / 1763.31 | 6 | 20 |
11 | 8 | -0.32 | 450 | 10.96 | 254 | 1253 | 6.06 / 1764.57 | 6 | 38 |
Average= | 27.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.60 | 84 | 10.97 | 329 | 303 | 0.30 / 1752.70 | 6 | 6 |
2 | 7 | 2014.68 | 105 | 8.45 | 1783 | 1582 | 1.89 / 1754.28 | 6 | 8 |
3 | 13 | 1945.04 | 36 | 8.66 | 1738 | 542 | 2.43 / 1754.82 | 5 | 10 |
4 | 13 | 1862.84 | 36 | 8.79 | 1678 | 531 | 2.96 / 1755.35 | 5 | 11 |
5 | 13 | 1570.80 | 36 | 9.09 | 1474 | 482 | 3.44 / 1755.84 | 5 | 15 |
6 | 13 | 1472.48 | 36 | 9.20 | 1406 | 466 | 3.91 / 1756.30 | 5 | 18 |
7 | 13 | 1049.92 | 36 | 9.61 | 1109 | 384 | 4.29 / 1756.69 | 5 | 23 |
8 | 13 | 731.04 | 36 | 9.97 | 872 | 313 | 4.60 / 1757.00 | 5 | 27 |
9 | 13 | 102.32 | 36 | 10.82 | 350 | 136 | 4.74 / 1757.13 | 6 | 21 |
10 | 13 | 25.88 | 36 | 10.93 | 282 | 111 | 4.85 / 1757.25 | 6 | 20 |
11 | 8 | -0.24 | 450 | 10.97 | 255 | 1259 | 6.11 / 1758.50 | 6 | 37 |
Average= | 27.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.92 | 84 | 10.98 | 323 | 298 | 0.30 / 1746.60 | 6 | 6 |
2 | 7 | 2003.68 | 105 | 8.51 | 1777 | 1588 | 1.89 / 1748.18 | 6 | 9 |
3 | 13 | 1928.28 | 36 | 8.76 | 1728 | 545 | 2.43 / 1748.73 | 5 | 10 |
4 | 13 | 1841.08 | 36 | 8.85 | 1664 | 530 | 2.96 / 1749.26 | 5 | 12 |
5 | 13 | 1746.80 | 36 | 8.97 | 1598 | 516 | 3.48 / 1749.78 | 5 | 14 |
6 | 13 | 1336.40 | 36 | 9.35 | 1314 | 442 | 3.92 / 1750.22 | 5 | 19 |
7 | 13 | 1033.08 | 36 | 9.65 | 1097 | 381 | 4.30 / 1750.60 | 5 | 24 |
8 | 13 | 523.60 | 36 | 10.24 | 708 | 261 | 4.56 / 1750.86 | 5 | 29 |
9 | 13 | 105.48 | 36 | 10.82 | 356 | 139 | 4.70 / 1751.00 | 6 | 22 |
10 | 13 | 28.76 | 36 | 10.92 | 288 | 113 | 4.81 / 1751.11 | 6 | 20 |
11 | 8 | -0.24 | 450 | 10.97 | 260 | 1283 | 6.10 / 1752.40 | 6 | 41 |
Average= | 27.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.76 | 84 | 10.98 | 325 | 300 | 0.30 / 1740.51 | 6 | 6 |
2 | 7 | 2014.88 | 105 | 8.53 | 1786 | 1600 | 1.90 / 1742.11 | 6 | 9 |
3 | 13 | 1940.44 | 36 | 8.76 | 1733 | 547 | 2.45 / 1742.65 | 5 | 11 |
4 | 13 | 1845.12 | 36 | 8.85 | 1675 | 534 | 2.98 / 1743.19 | 5 | 13 |
5 | 13 | 1648.80 | 36 | 9.08 | 1535 | 502 | 3.48 / 1743.69 | 5 | 16 |
6 | 13 | 1335.92 | 36 | 9.38 | 1314 | 444 | 3.93 / 1744.13 | 5 | 20 |
7 | 13 | 1019.96 | 36 | 9.69 | 1092 | 381 | 4.31 / 1744.51 | 5 | 24 |
8 | 13 | 601.04 | 36 | 10.16 | 768 | 281 | 4.59 / 1744.79 | 5 | 29 |
9 | 13 | 87.48 | 36 | 10.86 | 336 | 131 | 4.72 / 1744.93 | 6 | 21 |
10 | 13 | 20.84 | 36 | 10.95 | 277 | 109 | 4.83 / 1745.03 | 6 | 20 |
11 | 8 | -0.20 | 450 | 10.98 | 256 | 1265 | 6.09 / 1746.30 | 6 | 37 |
Average= | 28.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.92 | 84 | 11.00 | 317 | 293 | 0.29 / 1734.39 | 6 | 6 |
2 | 7 | 2007.88 | 105 | 8.57 | 1778 | 1600 | 1.89 / 1735.99 | 6 | 9 |
3 | 13 | 1938.76 | 36 | 8.78 | 1735 | 548 | 2.44 / 1736.54 | 5 | 11 |
4 | 13 | 1852.88 | 36 | 8.92 | 1673 | 537 | 2.98 / 1737.08 | 5 | 13 |
5 | 13 | 1754.80 | 36 | 9.03 | 1604 | 521 | 3.50 / 1737.60 | 5 | 15 |
6 | 13 | 1339.24 | 36 | 9.43 | 1309 | 444 | 3.94 / 1738.04 | 5 | 20 |
7 | 13 | 933.20 | 36 | 9.80 | 1025 | 362 | 4.31 / 1738.40 | 5 | 25 |
8 | 13 | 628.16 | 36 | 10.14 | 793 | 289 | 4.60 / 1738.69 | 5 | 28 |
9 | 13 | 97.24 | 36 | 10.84 | 345 | 135 | 4.73 / 1738.83 | 6 | 22 |
10 | 13 | 22.20 | 36 | 10.95 | 279 | 110 | 4.84 / 1738.94 | 6 | 20 |
11 | 8 | -0.32 | 450 | 10.97 | 257 | 1269 | 6.11 / 1740.21 | 6 | 44 |
Average= | 28.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.32 | 84 | 10.99 | 318 | 294 | 0.29 / 1728.31 | 6 | 6 |
2 | 7 | 2006.04 | 105 | 8.60 | 1776 | 1604 | 1.90 / 1729.92 | 6 | 9 |
3 | 13 | 1939.16 | 36 | 8.85 | 1732 | 552 | 2.45 / 1730.47 | 5 | 11 |
4 | 13 | 1855.28 | 36 | 8.92 | 1671 | 537 | 2.99 / 1731.01 | 5 | 12 |
5 | 13 | 1756.32 | 36 | 9.07 | 1599 | 522 | 3.51 / 1731.53 | 5 | 15 |
6 | 13 | 1336.36 | 36 | 9.47 | 1302 | 444 | 3.95 / 1731.97 | 5 | 20 |
7 | 13 | 926.84 | 36 | 9.85 | 1014 | 360 | 4.31 / 1732.33 | 5 | 25 |
8 | 13 | 618.48 | 36 | 10.17 | 780 | 286 | 4.60 / 1732.62 | 5 | 28 |
9 | 13 | 90.08 | 36 | 10.86 | 337 | 132 | 4.73 / 1732.75 | 6 | 22 |
10 | 13 | 20.56 | 36 | 10.95 | 274 | 108 | 4.84 / 1732.86 | 6 | 21 |
11 | 8 | -0.20 | 450 | 10.98 | 251 | 1240 | 6.08 / 1734.10 | 6 | 39 |
Average= | 28.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.32 | 84 | 10.99 | 318 | 294 | 0.29 / 1722.34 | 6 | 6 |
2 | 7 | 2007.00 | 106 | 8.64 | 1777 | 1627 | 1.92 / 1723.97 | 6 | 10 |
3 | 13 | 1938.36 | 36 | 8.86 | 1735 | 553 | 2.47 / 1724.52 | 5 | 11 |
4 | 13 | 1847.84 | 36 | 8.97 | 1663 | 537 | 3.01 / 1725.06 | 5 | 12 |
5 | 13 | 1648.68 | 36 | 9.20 | 1531 | 507 | 3.52 / 1725.57 | 5 | 16 |
6 | 13 | 1242.48 | 36 | 9.55 | 1247 | 429 | 3.95 / 1726.00 | 5 | 20 |
7 | 13 | 936.40 | 36 | 9.85 | 1022 | 362 | 4.31 / 1726.36 | 5 | 26 |
8 | 13 | 619.80 | 36 | 10.19 | 779 | 286 | 4.60 / 1726.64 | 5 | 29 |
9 | 13 | 89.64 | 36 | 10.87 | 335 | 131 | 4.73 / 1726.78 | 6 | 22 |
10 | 8 | -0.12 | 450 | 10.99 | 252 | 1246 | 5.97 / 1728.02 | 6 | 35 |
Average= | 29.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.12 | 84 | 10.98 | 312 | 288 | 0.29 / 1716.28 | 6 | 6 |
2 | 7 | 2005.04 | 105 | 8.66 | 1770 | 1609 | 1.90 / 1717.89 | 6 | 10 |
3 | 13 | 1937.88 | 36 | 8.88 | 1730 | 553 | 2.45 / 1718.44 | 5 | 12 |
4 | 13 | 1855.24 | 36 | 9.01 | 1669 | 541 | 2.99 / 1718.98 | 5 | 13 |
5 | 13 | 1762.00 | 36 | 9.12 | 1606 | 527 | 3.52 / 1719.51 | 5 | 16 |
6 | 13 | 1247.48 | 36 | 9.58 | 1242 | 428 | 3.95 / 1719.94 | 5 | 22 |
7 | 13 | 945.00 | 36 | 9.85 | 1028 | 365 | 4.31 / 1720.30 | 5 | 25 |
8 | 13 | 532.84 | 36 | 10.30 | 714 | 265 | 4.58 / 1720.57 | 5 | 29 |
9 | 13 | 93.04 | 36 | 10.86 | 340 | 133 | 4.71 / 1720.70 | 6 | 23 |
10 | 13 | 9.20 | 36 | 10.98 | 261 | 103 | 4.81 / 1720.80 | 6 | 21 |
11 | 8 | -0.20 | 450 | 10.98 | 252 | 1245 | 6.06 / 1722.05 | 6 | 39 |
Average= | 29.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.72 | 84 | 10.98 | 314 | 290 | 0.29 / 1710.44 | 6 | 6 |
2 | 7 | 1913.56 | 106 | 8.74 | 1704 | 1579 | 1.87 / 1712.02 | 6 | 11 |
3 | 13 | 1844.24 | 36 | 9.02 | 1657 | 538 | 2.41 / 1712.55 | 5 | 13 |
4 | 13 | 1758.84 | 36 | 9.10 | 1607 | 526 | 2.93 / 1713.08 | 5 | 13 |
5 | 13 | 1567.80 | 36 | 9.28 | 1469 | 491 | 3.42 / 1713.57 | 5 | 16 |
6 | 13 | 1266.60 | 36 | 9.56 | 1257 | 433 | 3.86 / 1714.00 | 5 | 21 |
7 | 13 | 857.48 | 36 | 9.94 | 965 | 345 | 4.20 / 1714.35 | 5 | 27 |
8 | 13 | 545.64 | 36 | 10.28 | 723 | 268 | 4.47 / 1714.62 | 5 | 30 |
9 | 13 | 48.96 | 36 | 10.92 | 302 | 119 | 4.59 / 1714.74 | 6 | 22 |
10 | 8 | -0.28 | 450 | 10.98 | 254 | 1255 | 5.84 / 1715.99 | 6 | 48 |
Average= | 30.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.00 | 84 | 10.98 | 322 | 297 | 0.30 / 1704.34 | 6 | 6 |
2 | 7 | 2005.28 | 105 | 8.67 | 1774 | 1615 | 1.91 / 1705.96 | 6 | 10 |
3 | 13 | 1936.20 | 36 | 8.93 | 1725 | 555 | 2.47 / 1706.51 | 5 | 11 |
4 | 13 | 1849.92 | 36 | 9.01 | 1675 | 543 | 3.01 / 1707.06 | 5 | 13 |
5 | 13 | 1653.92 | 36 | 9.21 | 1532 | 508 | 3.52 / 1707.57 | 5 | 16 |
6 | 13 | 1338.80 | 36 | 9.49 | 1315 | 449 | 3.97 / 1708.01 | 5 | 20 |
7 | 13 | 921.60 | 36 | 9.87 | 1019 | 362 | 4.33 / 1708.38 | 5 | 26 |
8 | 13 | 604.32 | 36 | 10.22 | 770 | 283 | 4.61 / 1708.66 | 5 | 29 |
9 | 13 | 83.32 | 36 | 10.88 | 331 | 130 | 4.74 / 1708.79 | 6 | 21 |
10 | 13 | 19.48 | 36 | 10.97 | 275 | 109 | 4.85 / 1708.90 | 6 | 22 |
11 | 8 | -0.16 | 450 | 10.98 | 253 | 1250 | 6.10 / 1710.15 | 6 | 39 |
Average= | 30.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.28 | 84 | 10.96 | 325 | 299 | 0.30 / 1698.36 | 6 | 6 |
2 | 7 | 2014.56 | 106 | 8.62 | 1781 | 1627 | 1.93 / 1699.99 | 6 | 9 |
3 | 13 | 1945.76 | 36 | 8.89 | 1740 | 557 | 2.48 / 1700.55 | 5 | 11 |
4 | 13 | 1860.28 | 36 | 9.01 | 1671 | 542 | 3.03 / 1701.09 | 5 | 13 |
5 | 13 | 1762.24 | 36 | 9.12 | 1599 | 525 | 3.55 / 1701.61 | 5 | 15 |
6 | 13 | 1253.84 | 36 | 9.55 | 1250 | 430 | 3.98 / 1702.04 | 5 | 21 |
7 | 13 | 950.44 | 36 | 9.85 | 1039 | 368 | 4.35 / 1702.41 | 5 | 26 |
8 | 13 | 527.28 | 36 | 10.31 | 704 | 261 | 4.61 / 1702.67 | 5 | 29 |
9 | 13 | 51.24 | 36 | 10.92 | 303 | 119 | 4.73 / 1702.79 | 6 | 21 |
10 | 8 | -0.24 | 450 | 10.97 | 254 | 1254 | 5.98 / 1704.05 | 6 | 36 |
Average= | 30.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.84 | 84 | 10.96 | 325 | 299 | 0.30 / 1692.28 | 6 | 6 |
2 | 7 | 2005.16 | 105 | 8.56 | 1771 | 1592 | 1.89 / 1693.87 | 6 | 9 |
3 | 13 | 1938.64 | 36 | 8.84 | 1734 | 552 | 2.44 / 1694.42 | 5 | 11 |
4 | 13 | 1852.04 | 36 | 8.96 | 1666 | 537 | 2.98 / 1694.96 | 5 | 13 |
5 | 13 | 1650.04 | 36 | 9.15 | 1529 | 504 | 3.48 / 1695.46 | 5 | 15 |
6 | 13 | 1243.60 | 36 | 9.54 | 1246 | 428 | 3.91 / 1695.89 | 5 | 21 |
7 | 13 | 1040.16 | 36 | 9.74 | 1104 | 387 | 4.30 / 1696.28 | 5 | 25 |
8 | 13 | 620.52 | 36 | 10.18 | 780 | 286 | 4.58 / 1696.57 | 5 | 29 |
9 | 13 | 95.44 | 36 | 10.85 | 341 | 133 | 4.72 / 1696.70 | 6 | 21 |
10 | 13 | 21.44 | 36 | 10.95 | 275 | 108 | 4.83 / 1696.81 | 6 | 21 |
11 | 8 | -0.12 | 450 | 10.96 | 255 | 1258 | 6.08 / 1698.06 | 6 | 42 |
Average= | 31.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.80 | 77 | 10.99 | 331 | 280 | 0.28 / 1686.23 | 6 | 6 |
2 | 10 | 1001.80 | 6 | 10.18 | 1076 | 66 | 0.35 / 1686.29 | 5 | 11 |
3 | 3 | 1013.84 | 1 | 10.22 | 1093 | 11 | 0.36 / 1686.30 | 5 | 5 |
4 | 7 | 2005.64 | 105 | 8.57 | 1761 | 1585 | 1.94 / 1687.89 | 5 | 9 |
5 | 13 | 1939.32 | 36 | 8.86 | 1723 | 550 | 2.49 / 1688.44 | 5 | 11 |
6 | 13 | 1854.60 | 36 | 8.96 | 1666 | 537 | 3.03 / 1688.98 | 5 | 14 |
7 | 13 | 1756.08 | 36 | 9.09 | 1601 | 524 | 3.55 / 1689.50 | 5 | 15 |
8 | 13 | 1324.36 | 36 | 9.51 | 1301 | 445 | 4.00 / 1689.95 | 5 | 21 |
9 | 13 | 1018.04 | 36 | 9.79 | 1082 | 381 | 4.38 / 1690.33 | 5 | 25 |
10 | 13 | 592.56 | 36 | 10.24 | 759 | 280 | 4.66 / 1690.61 | 5 | 29 |
11 | 13 | 78.20 | 36 | 10.89 | 322 | 126 | 4.79 / 1690.73 | 6 | 22 |
12 | 8 | -0.12 | 450 | 10.96 | 253 | 1248 | 6.03 / 1691.98 | 6 | 38 |
Average= | 31.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.28 | 70 | 11.59 | 328 | 266 | 0.27 / 1680.19 | 6 | 6 |
2 | 10 | 1027.56 | 5 | 11.27 | 1116 | 63 | 0.33 / 1680.26 | 5 | 12 |
3 | 3 | 1037.12 | 2 | 11.21 | 1134 | 25 | 0.35 / 1680.28 | 5 | 8 |
4 | 7 | 2006.24 | 106 | 8.40 | 1770 | 1576 | 1.93 / 1681.86 | 8 | 6 |
5 | 13 | 1936.60 | 36 | 9.08 | 1729 | 565 | 2.50 / 1682.42 | 5 | 11 |
6 | 13 | 1849.16 | 36 | 9.13 | 1674 | 550 | 3.05 / 1682.97 | 5 | 14 |
7 | 13 | 1551.68 | 36 | 9.44 | 1461 | 497 | 3.54 / 1683.47 | 5 | 17 |
8 | 13 | 1347.12 | 36 | 9.64 | 1319 | 458 | 4.00 / 1683.93 | 5 | 22 |
9 | 13 | 937.40 | 36 | 10.02 | 1028 | 371 | 4.37 / 1684.30 | 5 | 27 |
10 | 13 | 518.36 | 36 | 10.44 | 700 | 263 | 4.63 / 1684.56 | 5 | 30 |
11 | 13 | 47.56 | 36 | 10.97 | 298 | 118 | 4.75 / 1684.68 | 6 | 21 |
12 | 8 | -0.08 | 450 | 11.00 | 256 | 1267 | 6.02 / 1685.95 | 6 | 35 |
Average= | 32.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.68 | 65 | 12.69 | 339 | 280 | 0.28 / 1674.18 | 6 | 7 |
2 | 10 | 1001.44 | 5 | 12.33 | 1109 | 68 | 0.35 / 1674.25 | 5 | 18 |
3 | 3 | 1015.36 | 1 | 12.06 | 1132 | 14 | 0.36 / 1674.26 | 5 | 5 |
4 | 7 | 2003.60 | 105 | 8.52 | 1763 | 1577 | 1.94 / 1675.84 | 5 | 9 |
5 | 13 | 1931.32 | 36 | 9.70 | 1741 | 608 | 2.55 / 1676.45 | 5 | 12 |
6 | 13 | 1841.56 | 36 | 9.76 | 1667 | 586 | 3.13 / 1677.04 | 5 | 15 |
7 | 13 | 1643.96 | 36 | 9.99 | 1531 | 551 | 3.68 / 1677.59 | 5 | 19 |
8 | 13 | 1222.44 | 36 | 10.36 | 1240 | 462 | 4.15 / 1678.05 | 5 | 25 |
9 | 13 | 899.24 | 36 | 10.59 | 1000 | 381 | 4.53 / 1678.43 | 5 | 29 |
10 | 13 | 264.36 | 36 | 11.32 | 479 | 195 | 4.72 / 1678.63 | 5 | 29 |
11 | 8 | -0.32 | 450 | 11.45 | 253 | 1304 | 6.03 / 1679.93 | 6 | 37 |
Average= | 32.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.12 | 62 | 13.48 | 348 | 291 | 0.29 / 1668.02 | 6 | 7 |
2 | 3 | 1049.24 | 2 | 12.68 | 1164 | 30 | 0.32 / 1668.05 | 5 | 15 |
3 | 7 | 2002.76 | 106 | 7.64 | 1739 | 1408 | 1.73 / 1669.46 | 15 | 6 |
4 | 13 | 1941.64 | 36 | 9.72 | 1752 | 613 | 2.34 / 1670.07 | 5 | 13 |
5 | 13 | 1862.80 | 36 | 9.86 | 1695 | 602 | 2.94 / 1670.67 | 5 | 16 |
6 | 13 | 1767.48 | 36 | 10.13 | 1630 | 594 | 3.54 / 1671.27 | 5 | 19 |
7 | 13 | 1240.12 | 36 | 10.84 | 1263 | 493 | 4.03 / 1671.76 | 5 | 26 |
8 | 13 | 838.64 | 36 | 11.27 | 973 | 395 | 4.43 / 1672.16 | 5 | 33 |
9 | 13 | 422.20 | 36 | 11.82 | 632 | 269 | 4.69 / 1672.42 | 5 | 34 |
10 | 8 | 0.00 | 450 | 12.17 | 270 | 1479 | 6.17 / 1673.90 | 6 | 40 |
Average= | 33.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.84 | 62 | 14.02 | 363 | 316 | 0.32 / 1661.62 | 6 | 7 |
2 | 3 | 1010.20 | 1 | 12.53 | 1119 | 14 | 0.33 / 1661.64 | 5 | 5 |
3 | 7 | 2006.04 | 106 | 7.22 | 1750 | 1339 | 1.67 / 1662.98 | 5 | 6 |
4 | 13 | 1953.16 | 36 | 10.12 | 1767 | 644 | 2.31 / 1663.62 | 5 | 15 |
5 | 13 | 1879.08 | 36 | 10.38 | 1712 | 640 | 2.95 / 1664.26 | 5 | 19 |
6 | 13 | 1782.56 | 36 | 10.56 | 1650 | 627 | 3.58 / 1664.89 | 5 | 21 |
7 | 13 | 1367.00 | 36 | 11.27 | 1364 | 553 | 4.13 / 1665.44 | 5 | 28 |
8 | 13 | 938.84 | 36 | 11.82 | 1056 | 449 | 4.58 / 1665.89 | 5 | 35 |
9 | 13 | 298.96 | 36 | 12.95 | 540 | 252 | 4.83 / 1666.14 | 5 | 36 |
10 | 8 | -0.20 | 450 | 12.94 | 273 | 1590 | 6.42 / 1667.73 | 6 | 43 |
Average= | 34.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.88 | 62 | 14.28 | 348 | 308 | 0.31 / 1655.07 | 6 | 7 |
2 | 7 | 2008.76 | 105 | 6.90 | 1748 | 1266 | 1.57 / 1656.34 | 7 | 5 |
3 | 13 | 1969.00 | 36 | 10.23 | 1773 | 653 | 2.23 / 1656.99 | 5 | 16 |
4 | 13 | 1892.40 | 36 | 10.50 | 1717 | 649 | 2.88 / 1657.64 | 5 | 19 |
5 | 13 | 1794.44 | 36 | 10.78 | 1655 | 642 | 3.52 / 1658.28 | 5 | 20 |
6 | 13 | 1365.32 | 36 | 12.05 | 1369 | 594 | 4.11 / 1658.88 | 5 | 31 |
7 | 13 | 844.92 | 36 | 12.95 | 999 | 466 | 4.58 / 1659.34 | 5 | 42 |
8 | 13 | 320.76 | 36 | 13.63 | 564 | 277 | 4.86 / 1659.62 | 5 | 41 |
9 | 8 | 0.04 | 450 | 13.52 | 277 | 1685 | 6.54 / 1661.31 | 6 | 43 |
Average= | 34.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.60 | 62 | 14.36 | 351 | 313 | 0.31 / 1648.43 | 6 | 7 |
2 | 7 | 2005.40 | 106 | 7.20 | 1754 | 1339 | 1.65 / 1649.77 | 7 | 6 |
3 | 13 | 1956.60 | 36 | 10.49 | 1772 | 669 | 2.32 / 1650.44 | 5 | 12 |
4 | 13 | 1876.88 | 36 | 10.80 | 1713 | 666 | 2.99 / 1651.10 | 5 | 18 |
5 | 13 | 1679.36 | 36 | 11.71 | 1587 | 669 | 3.66 / 1651.77 | 5 | 26 |
6 | 13 | 1256.92 | 36 | 12.81 | 1303 | 601 | 4.26 / 1652.37 | 5 | 37 |
7 | 13 | 725.68 | 36 | 13.40 | 915 | 441 | 4.70 / 1652.81 | 5 | 44 |
8 | 13 | 170.84 | 36 | 14.09 | 438 | 222 | 4.92 / 1653.04 | 6 | 36 |
9 | 8 | 0.00 | 450 | 13.88 | 277 | 1730 | 6.65 / 1654.77 | 6 | 52 |
Average= | 35.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.88 | 62 | 14.39 | 352 | 314 | 0.31 / 1641.77 | 6 | 7 |
2 | 7 | 2007.56 | 105 | 7.38 | 1752 | 1358 | 1.67 / 1643.13 | 7 | 5 |
3 | 13 | 1959.72 | 36 | 10.74 | 1771 | 685 | 2.36 / 1643.81 | 5 | 15 |
4 | 13 | 1875.92 | 36 | 11.12 | 1720 | 689 | 3.04 / 1644.50 | 5 | 22 |
5 | 13 | 1680.48 | 36 | 12.19 | 1587 | 696 | 3.74 / 1645.20 | 5 | 29 |
6 | 13 | 1154.16 | 36 | 13.16 | 1230 | 583 | 4.32 / 1645.78 | 5 | 40 |
7 | 13 | 630.64 | 36 | 13.68 | 829 | 408 | 4.73 / 1646.19 | 5 | 47 |
8 | 13 | 89.16 | 36 | 14.26 | 359 | 184 | 4.92 / 1646.37 | 6 | 36 |
9 | 8 | -0.08 | 450 | 14.09 | 275 | 1744 | 6.66 / 1648.12 | 6 | 45 |
Average= | 35.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.92 | 62 | 14.41 | 348 | 311 | 0.31 / 1635.06 | 6 | 7 |
2 | 7 | 2004.00 | 105 | 7.73 | 1757 | 1426 | 1.74 / 1636.48 | 7 | 7 |
3 | 13 | 1945.28 | 36 | 11.02 | 1768 | 701 | 2.44 / 1637.19 | 5 | 20 |
4 | 13 | 1857.64 | 36 | 11.49 | 1709 | 707 | 3.15 / 1637.89 | 5 | 23 |
5 | 13 | 1552.08 | 36 | 12.73 | 1507 | 691 | 3.84 / 1638.58 | 5 | 32 |
6 | 13 | 1122.80 | 36 | 13.27 | 1206 | 576 | 4.41 / 1639.16 | 5 | 41 |
7 | 13 | 479.32 | 36 | 13.86 | 702 | 350 | 4.76 / 1639.51 | 5 | 45 |
8 | 13 | 15.20 | 36 | 14.33 | 301 | 155 | 4.92 / 1639.66 | 6 | 34 |
9 | 8 | -0.16 | 450 | 14.16 | 281 | 1791 | 6.71 / 1641.46 | 6 | 57 |
Average= | 36.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.60 | 62 | 14.41 | 354 | 316 | 0.32 / 1628.31 | 6 | 8 |
2 | 7 | 2003.20 | 105 | 7.78 | 1758 | 1436 | 1.75 / 1629.75 | 8 | 6 |
3 | 13 | 1940.84 | 36 | 11.23 | 1772 | 716 | 2.47 / 1630.46 | 5 | 19 |
4 | 13 | 1852.04 | 36 | 11.79 | 1713 | 727 | 3.20 / 1631.19 | 5 | 25 |
5 | 13 | 1447.92 | 36 | 12.93 | 1440 | 670 | 3.87 / 1631.86 | 5 | 35 |
6 | 13 | 1026.56 | 36 | 13.37 | 1145 | 551 | 4.42 / 1632.41 | 5 | 43 |
7 | 13 | 489.08 | 36 | 13.85 | 724 | 361 | 4.78 / 1632.77 | 5 | 46 |
8 | 13 | 30.04 | 36 | 14.32 | 322 | 166 | 4.94 / 1632.94 | 6 | 34 |
9 | 8 | 0.04 | 450 | 14.24 | 282 | 1807 | 6.75 / 1634.75 | 11 | 66 |
Average= | 37.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.80 | 62 | 14.38 | 360 | 321 | 0.32 / 1621.65 | 6 | 8 |
2 | 7 | 2014.32 | 105 | 7.88 | 1769 | 1464 | 1.78 / 1623.11 | 8 | 8 |
3 | 13 | 1952.40 | 36 | 11.43 | 1783 | 734 | 2.52 / 1623.84 | 5 | 22 |
4 | 13 | 1869.04 | 36 | 11.96 | 1732 | 746 | 3.26 / 1624.59 | 5 | 28 |
5 | 13 | 1461.96 | 36 | 12.96 | 1456 | 679 | 3.94 / 1625.27 | 5 | 37 |
6 | 13 | 1141.24 | 36 | 13.30 | 1229 | 588 | 4.53 / 1625.86 | 5 | 41 |
7 | 13 | 361.88 | 36 | 13.99 | 608 | 306 | 4.84 / 1626.16 | 5 | 45 |
8 | 8 | -0.16 | 450 | 14.30 | 285 | 1834 | 6.67 / 1628.00 | 6 | 55 |
Average= | 37.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.12 | 62 | 14.38 | 366 | 326 | 0.33 / 1615.03 | 6 | 8 |
2 | 7 | 2003.40 | 105 | 7.97 | 1763 | 1475 | 1.80 / 1616.51 | 8 | 8 |
3 | 13 | 1945.16 | 36 | 11.61 | 1786 | 746 | 2.55 / 1617.25 | 5 | 23 |
4 | 13 | 1858.68 | 36 | 12.08 | 1727 | 751 | 3.30 / 1618.00 | 5 | 27 |
5 | 13 | 1453.52 | 36 | 12.98 | 1446 | 676 | 3.97 / 1618.68 | 5 | 36 |
6 | 13 | 924.00 | 36 | 13.49 | 1070 | 520 | 4.49 / 1619.20 | 5 | 44 |
7 | 13 | 285.72 | 36 | 14.07 | 543 | 275 | 4.77 / 1619.47 | 5 | 43 |
8 | 8 | 0.00 | 450 | 14.32 | 287 | 1849 | 6.62 / 1621.32 | 6 | 59 |
Average= | 38.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.84 | 62 | 14.37 | 362 | 323 | 0.32 / 1608.37 | 6 | 8 |
2 | 7 | 2003.84 | 105 | 7.92 | 1765 | 1468 | 1.79 / 1609.84 | 8 | 8 |
3 | 13 | 1947.52 | 36 | 11.72 | 1794 | 757 | 2.55 / 1610.60 | 5 | 22 |
4 | 13 | 1859.00 | 36 | 12.18 | 1729 | 758 | 3.31 / 1611.36 | 5 | 28 |
5 | 13 | 1440.72 | 36 | 13.02 | 1443 | 676 | 3.98 / 1612.03 | 5 | 36 |
6 | 13 | 1005.76 | 36 | 13.45 | 1129 | 547 | 4.53 / 1612.58 | 5 | 43 |
7 | 13 | 260.16 | 36 | 14.11 | 523 | 266 | 4.79 / 1612.85 | 5 | 43 |
8 | 8 | -0.04 | 450 | 14.35 | 288 | 1860 | 6.65 / 1614.71 | 6 | 58 |
Average= | 39.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.64 | 62 | 14.40 | 356 | 318 | 0.32 / 1601.72 | 6 | 7 |
2 | 7 | 2013.20 | 105 | 7.94 | 1767 | 1473 | 1.79 / 1603.19 | 7 | 6 |
3 | 13 | 1954.76 | 36 | 11.88 | 1798 | 769 | 2.56 / 1603.96 | 5 | 22 |
4 | 13 | 1871.28 | 36 | 12.27 | 1735 | 766 | 3.33 / 1604.73 | 5 | 28 |
5 | 13 | 1352.96 | 36 | 13.16 | 1380 | 654 | 3.98 / 1605.38 | 5 | 38 |
6 | 13 | 939.12 | 36 | 13.52 | 1083 | 527 | 4.51 / 1605.91 | 5 | 46 |
7 | 13 | 302.72 | 36 | 14.07 | 560 | 284 | 4.79 / 1606.19 | 5 | 44 |
8 | 8 | -0.12 | 450 | 14.38 | 287 | 1857 | 6.65 / 1608.05 | 6 | 54 |
Average= | 40.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.52 | 62 | 14.43 | 353 | 316 | 0.32 / 1594.90 | 6 | 8 |
2 | 7 | 2005.00 | 106 | 7.76 | 1758 | 1446 | 1.76 / 1596.34 | 8 | 6 |
3 | 13 | 1950.04 | 36 | 11.93 | 1792 | 770 | 2.53 / 1597.11 | 5 | 24 |
4 | 13 | 1864.48 | 36 | 12.26 | 1735 | 766 | 3.30 / 1597.88 | 5 | 28 |
5 | 13 | 1451.96 | 36 | 13.07 | 1448 | 681 | 3.98 / 1598.56 | 5 | 37 |
6 | 13 | 940.88 | 36 | 13.54 | 1081 | 527 | 4.51 / 1599.09 | 5 | 45 |
7 | 13 | 308.44 | 36 | 14.07 | 566 | 287 | 4.79 / 1599.37 | 5 | 44 |
8 | 13 | 42.92 | 36 | 14.31 | 336 | 173 | 4.97 / 1599.54 | 6 | 32 |
9 | 8 | -0.12 | 450 | 14.39 | 287 | 1858 | 6.82 / 1601.40 | 6 | 57 |
Average= | 41.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.84 | 62 | 14.41 | 352 | 314 | 0.31 / 1588.24 | 6 | 7 |
2 | 7 | 2004.68 | 106 | 7.71 | 1755 | 1434 | 1.75 / 1589.67 | 5 | 7 |
3 | 13 | 1948.88 | 36 | 12.01 | 1792 | 775 | 2.52 / 1590.45 | 5 | 24 |
4 | 13 | 1856.92 | 36 | 12.29 | 1736 | 768 | 3.29 / 1591.21 | 5 | 28 |
5 | 13 | 1542.40 | 36 | 12.95 | 1514 | 706 | 4.00 / 1591.92 | 5 | 35 |
6 | 13 | 1001.28 | 36 | 13.51 | 1125 | 547 | 4.54 / 1592.47 | 5 | 45 |
7 | 13 | 251.08 | 36 | 14.12 | 513 | 261 | 4.81 / 1592.73 | 6 | 37 |
8 | 8 | -0.04 | 450 | 14.39 | 286 | 1852 | 6.66 / 1594.58 | 6 | 61 |
Average= | 41.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.04 | 62 | 14.42 | 350 | 313 | 0.31 / 1581.55 | 6 | 7 |
2 | 7 | 2006.24 | 105 | 7.62 | 1764 | 1411 | 1.72 / 1582.96 | 7 | 6 |
3 | 13 | 1957.12 | 36 | 12.02 | 1804 | 781 | 2.50 / 1583.74 | 5 | 23 |
4 | 13 | 1871.44 | 36 | 12.32 | 1743 | 773 | 3.28 / 1584.51 | 5 | 28 |
5 | 13 | 1556.16 | 36 | 12.96 | 1523 | 711 | 3.99 / 1585.22 | 5 | 36 |
6 | 13 | 1021.20 | 36 | 13.50 | 1143 | 555 | 4.54 / 1585.78 | 5 | 45 |
7 | 13 | 367.44 | 36 | 14.03 | 612 | 309 | 4.85 / 1586.09 | 5 | 44 |
8 | 8 | 0.08 | 450 | 14.40 | 283 | 1834 | 6.69 / 1587.92 | 6 | 60 |
Average= | 42.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.52 | 62 | 14.41 | 349 | 312 | 0.31 / 1574.98 | 6 | 6 |
2 | 7 | 2015.40 | 105 | 7.68 | 1773 | 1430 | 1.74 / 1576.41 | 6 | 7 |
3 | 13 | 1955.84 | 36 | 12.09 | 1797 | 782 | 2.52 / 1577.20 | 5 | 26 |
4 | 13 | 1864.28 | 36 | 12.36 | 1740 | 774 | 3.30 / 1577.97 | 5 | 27 |
5 | 13 | 1351.40 | 36 | 13.22 | 1383 | 658 | 3.96 / 1578.63 | 5 | 39 |
6 | 13 | 942.56 | 36 | 13.56 | 1082 | 528 | 4.48 / 1579.16 | 5 | 45 |
7 | 13 | 206.24 | 36 | 14.16 | 469 | 239 | 4.72 / 1579.40 | 6 | 38 |
8 | 8 | -0.04 | 450 | 14.39 | 284 | 1839 | 6.56 / 1581.24 | 6 | 59 |
Average= | 43.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.72 | 62 | 14.39 | 347 | 310 | 0.31 / 1568.23 | 6 | 6 |
2 | 7 | 2015.64 | 105 | 7.73 | 1758 | 1427 | 1.74 / 1569.66 | 6 | 7 |
3 | 13 | 1954.52 | 36 | 12.12 | 1796 | 784 | 2.52 / 1570.44 | 5 | 23 |
4 | 13 | 1864.64 | 36 | 12.38 | 1734 | 773 | 3.29 / 1571.22 | 5 | 28 |
5 | 13 | 1439.68 | 36 | 13.15 | 1442 | 683 | 3.98 / 1571.90 | 5 | 36 |
6 | 13 | 914.96 | 36 | 13.59 | 1062 | 520 | 4.50 / 1572.42 | 5 | 45 |
7 | 13 | 278.40 | 36 | 14.08 | 536 | 272 | 4.77 / 1572.69 | 5 | 39 |
8 | 13 | 2.44 | 36 | 14.33 | 295 | 152 | 4.92 / 1572.84 | 6 | 29 |
9 | 8 | 0.04 | 450 | 14.38 | 283 | 1831 | 6.75 / 1574.67 | 6 | 62 |
Average= | 44.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.12 | 62 | 14.39 | 358 | 319 | 0.32 / 1561.46 | 6 | 6 |
2 | 7 | 2010.80 | 105 | 7.78 | 1760 | 1438 | 1.76 / 1562.90 | 6 | 7 |
3 | 13 | 1957.24 | 36 | 12.15 | 1799 | 787 | 2.54 / 1563.69 | 5 | 22 |
4 | 13 | 1871.20 | 36 | 12.41 | 1742 | 778 | 3.32 / 1564.47 | 5 | 28 |
5 | 13 | 1350.20 | 36 | 13.26 | 1382 | 660 | 3.98 / 1565.13 | 5 | 39 |
6 | 13 | 935.92 | 36 | 13.57 | 1082 | 529 | 4.51 / 1565.65 | 5 | 45 |
7 | 13 | 287.64 | 36 | 14.07 | 543 | 275 | 4.79 / 1565.93 | 5 | 42 |
8 | 13 | 42.24 | 36 | 14.29 | 327 | 168 | 4.95 / 1566.10 | 6 | 33 |
9 | 8 | -0.04 | 450 | 14.38 | 282 | 1825 | 6.78 / 1567.92 | 6 | 60 |
Average= | 46.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.16 | 62 | 14.38 | 356 | 317 | 0.32 / 1554.59 | 6 | 6 |
2 | 7 | 2005.32 | 105 | 7.79 | 1764 | 1443 | 1.76 / 1556.04 | 6 | 7 |
3 | 13 | 1948.24 | 36 | 12.19 | 1795 | 788 | 2.55 / 1556.82 | 5 | 23 |
4 | 13 | 1858.88 | 36 | 12.44 | 1735 | 777 | 3.32 / 1557.60 | 5 | 29 |
5 | 13 | 1432.00 | 36 | 13.20 | 1438 | 683 | 4.01 / 1558.28 | 5 | 39 |
6 | 13 | 999.84 | 36 | 13.55 | 1127 | 550 | 4.56 / 1558.83 | 5 | 44 |
7 | 13 | 337.32 | 36 | 14.02 | 590 | 298 | 4.86 / 1559.13 | 5 | 44 |
8 | 13 | 51.40 | 36 | 14.26 | 341 | 175 | 5.03 / 1559.31 | 6 | 35 |
9 | 8 | -0.16 | 450 | 14.37 | 284 | 1836 | 6.87 / 1561.14 | 6 | 62 |
Average= | 47.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.16 | 62 | 14.39 | 354 | 316 | 0.32 / 1547.89 | 6 | 7 |
2 | 7 | 2004.56 | 105 | 7.85 | 1763 | 1453 | 1.77 / 1549.34 | 7 | 6 |
3 | 13 | 1945.28 | 36 | 12.23 | 1797 | 791 | 2.56 / 1550.14 | 5 | 24 |
4 | 13 | 1853.56 | 36 | 12.46 | 1735 | 778 | 3.34 / 1550.91 | 5 | 29 |
5 | 13 | 1447.44 | 36 | 13.20 | 1454 | 691 | 4.03 / 1551.60 | 5 | 37 |
6 | 13 | 1007.76 | 36 | 13.54 | 1139 | 555 | 4.58 / 1552.16 | 5 | 45 |
7 | 13 | 252.72 | 36 | 14.09 | 517 | 262 | 4.85 / 1552.42 | 5 | 42 |
8 | 8 | 0.04 | 450 | 14.36 | 287 | 1855 | 6.70 / 1554.28 | 6 | 63 |
Average= | 48.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.04 | 62 | 14.39 | 348 | 310 | 0.31 / 1541.08 | 6 | 7 |
2 | 7 | 2003.36 | 105 | 7.86 | 1756 | 1449 | 1.76 / 1542.53 | 7 | 7 |
3 | 13 | 1943.00 | 36 | 12.26 | 1793 | 791 | 2.55 / 1543.32 | 5 | 24 |
4 | 13 | 1855.08 | 36 | 12.52 | 1729 | 779 | 3.33 / 1544.10 | 5 | 29 |
5 | 13 | 1431.36 | 36 | 13.24 | 1437 | 685 | 4.02 / 1544.79 | 5 | 39 |
6 | 13 | 903.80 | 36 | 13.62 | 1048 | 514 | 4.53 / 1545.30 | 5 | 45 |
7 | 13 | 259.32 | 36 | 14.08 | 519 | 263 | 4.79 / 1545.56 | 5 | 41 |
8 | 13 | 1.76 | 36 | 14.30 | 300 | 154 | 4.95 / 1545.72 | 6 | 32 |
9 | 8 | -0.08 | 450 | 14.34 | 288 | 1858 | 6.81 / 1547.57 | 6 | 61 |
Average= | 49.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.40 | 62 | 14.41 | 351 | 314 | 0.31 / 1534.27 | 6 | 6 |
2 | 7 | 2005.76 | 105 | 7.83 | 1751 | 1440 | 1.75 / 1535.71 | 6 | 6 |
3 | 13 | 1951.92 | 36 | 12.26 | 1798 | 794 | 2.55 / 1536.51 | 5 | 25 |
4 | 13 | 1862.56 | 36 | 12.50 | 1742 | 784 | 3.33 / 1537.29 | 5 | 30 |
5 | 13 | 1431.44 | 36 | 13.24 | 1440 | 686 | 4.02 / 1537.98 | 5 | 38 |
6 | 13 | 892.04 | 36 | 13.62 | 1049 | 514 | 4.53 / 1538.49 | 5 | 45 |
7 | 13 | 256.80 | 36 | 14.08 | 517 | 262 | 4.79 / 1538.75 | 5 | 43 |
8 | 13 | 31.76 | 36 | 14.26 | 325 | 167 | 4.96 / 1538.92 | 6 | 33 |
9 | 8 | -0.24 | 450 | 14.33 | 287 | 1851 | 6.81 / 1540.77 | 6 | 67 |
Average= | 51.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.00 | 62 | 14.40 | 348 | 311 | 0.31 / 1527.43 | 6 | 6 |
2 | 7 | 2003.52 | 105 | 7.77 | 1752 | 1429 | 1.74 / 1528.86 | 5 | 6 |
3 | 13 | 1942.84 | 36 | 12.28 | 1797 | 794 | 2.53 / 1529.65 | 5 | 24 |
4 | 13 | 1851.64 | 36 | 12.55 | 1727 | 780 | 3.31 / 1530.43 | 5 | 29 |
5 | 13 | 1526.04 | 36 | 13.17 | 1507 | 714 | 4.03 / 1531.15 | 5 | 38 |
6 | 13 | 878.08 | 36 | 13.62 | 1037 | 508 | 4.54 / 1531.66 | 5 | 45 |
7 | 13 | 341.84 | 36 | 14.01 | 597 | 301 | 4.84 / 1531.96 | 5 | 43 |
8 | 13 | 24.88 | 36 | 14.28 | 314 | 161 | 5.00 / 1532.12 | 6 | 33 |
9 | 8 | -0.16 | 450 | 14.34 | 285 | 1839 | 6.84 / 1533.96 | 6 | 66 |
Average= | 52.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.96 | 62 | 14.36 | 347 | 309 | 0.31 / 1520.64 | 6 | 6 |
2 | 7 | 2004.16 | 106 | 7.81 | 1753 | 1451 | 1.76 / 1522.10 | 6 | 6 |
3 | 13 | 1943.60 | 36 | 12.29 | 1788 | 791 | 2.55 / 1522.89 | 5 | 26 |
4 | 13 | 1852.64 | 36 | 12.54 | 1732 | 782 | 3.33 / 1523.67 | 5 | 31 |
5 | 13 | 1433.32 | 36 | 13.26 | 1435 | 685 | 4.02 / 1524.35 | 5 | 39 |
6 | 13 | 902.80 | 36 | 13.60 | 1058 | 518 | 4.54 / 1524.87 | 5 | 45 |
7 | 13 | 260.24 | 36 | 14.08 | 519 | 263 | 4.80 / 1525.13 | 6 | 43 |
8 | 13 | 37.00 | 36 | 14.27 | 322 | 165 | 4.96 / 1525.30 | 6 | 33 |
9 | 8 | -0.12 | 450 | 14.34 | 282 | 1820 | 6.78 / 1527.12 | 6 | 65 |
Average= | 54.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.20 | 62 | 14.37 | 348 | 310 | 0.31 / 1513.87 | 6 | 6 |
2 | 7 | 2005.40 | 106 | 7.80 | 1756 | 1452 | 1.76 / 1515.32 | 6 | 7 |
3 | 13 | 1944.28 | 36 | 12.33 | 1795 | 797 | 2.56 / 1516.12 | 5 | 27 |
4 | 13 | 1848.04 | 36 | 12.58 | 1727 | 782 | 3.34 / 1516.90 | 5 | 30 |
5 | 13 | 1322.16 | 36 | 13.34 | 1366 | 656 | 4.00 / 1517.56 | 5 | 38 |
6 | 13 | 903.44 | 36 | 13.59 | 1061 | 519 | 4.52 / 1518.08 | 5 | 45 |
7 | 13 | 273.52 | 36 | 14.06 | 533 | 270 | 4.79 / 1518.35 | 5 | 42 |
8 | 13 | 34.56 | 36 | 14.27 | 321 | 165 | 4.95 / 1518.51 | 6 | 34 |
9 | 8 | -0.32 | 450 | 14.33 | 283 | 1825 | 6.78 / 1520.34 | 6 | 57 |
Average= | 56.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.60 | 62 | 14.36 | 352 | 313 | 0.31 / 1507.06 | 6 | 7 |
2 | 7 | 2004.84 | 105 | 7.84 | 1749 | 1440 | 1.75 / 1508.50 | 7 | 7 |
3 | 13 | 1947.56 | 36 | 12.35 | 1799 | 800 | 2.55 / 1509.30 | 5 | 26 |
4 | 13 | 1857.00 | 36 | 12.60 | 1737 | 788 | 3.34 / 1510.09 | 5 | 31 |
5 | 13 | 1437.92 | 36 | 13.26 | 1444 | 689 | 4.03 / 1510.78 | 5 | 39 |
6 | 13 | 902.68 | 36 | 13.61 | 1056 | 517 | 4.55 / 1511.29 | 5 | 45 |
7 | 13 | 265.24 | 36 | 14.06 | 527 | 267 | 4.81 / 1511.56 | 5 | 40 |
8 | 13 | 33.40 | 36 | 14.25 | 320 | 164 | 4.98 / 1511.72 | 6 | 34 |
9 | 8 | -0.24 | 450 | 14.31 | 285 | 1835 | 6.81 / 1513.56 | 6 | 63 |
Average= | 58.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.76 | 62 | 14.37 | 347 | 309 | 0.31 / 1500.20 | 6 | 6 |
2 | 7 | 2014.24 | 105 | 7.83 | 1761 | 1448 | 1.76 / 1501.65 | 6 | 7 |
3 | 13 | 1951.92 | 36 | 12.35 | 1798 | 799 | 2.56 / 1502.45 | 5 | 28 |
4 | 13 | 1856.16 | 36 | 12.61 | 1736 | 788 | 3.34 / 1503.24 | 5 | 30 |
5 | 13 | 1427.76 | 36 | 13.28 | 1430 | 684 | 4.03 / 1503.92 | 5 | 38 |
6 | 13 | 1007.52 | 36 | 13.53 | 1132 | 551 | 4.58 / 1504.47 | 5 | 43 |
7 | 13 | 256.24 | 36 | 14.07 | 516 | 261 | 4.84 / 1504.74 | 5 | 39 |
8 | 13 | 31.24 | 36 | 14.26 | 317 | 163 | 5.00 / 1504.90 | 6 | 33 |
9 | 8 | -0.20 | 450 | 14.31 | 287 | 1848 | 6.85 / 1506.75 | 6 | 55 |
Average= | 60.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.04 | 62 | 14.36 | 350 | 312 | 0.31 / 1493.37 | 6 | 6 |
2 | 7 | 2015.80 | 106 | 7.83 | 1767 | 1467 | 1.78 / 1494.83 | 6 | 7 |
3 | 13 | 1950.52 | 36 | 12.36 | 1806 | 804 | 2.58 / 1495.64 | 5 | 27 |
4 | 13 | 1854.04 | 36 | 12.63 | 1734 | 788 | 3.37 / 1496.43 | 5 | 30 |
5 | 13 | 1434.16 | 36 | 13.28 | 1432 | 685 | 4.05 / 1497.11 | 5 | 38 |
6 | 13 | 996.80 | 36 | 13.54 | 1128 | 550 | 4.60 / 1497.66 | 5 | 43 |
7 | 13 | 242.48 | 36 | 14.07 | 507 | 257 | 4.86 / 1497.92 | 5 | 39 |
8 | 13 | 27.88 | 36 | 14.25 | 315 | 162 | 5.02 / 1498.08 | 6 | 36 |
9 | 8 | -0.24 | 450 | 14.31 | 282 | 1816 | 6.84 / 1499.89 | 6 | 55 |
Average= | 62.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.76 | 62 | 14.32 | 354 | 314 | 0.31 / 1486.60 | 6 | 6 |
2 | 7 | 2005.32 | 106 | 7.84 | 1759 | 1462 | 1.78 / 1488.06 | 6 | 7 |
3 | 13 | 1946.24 | 36 | 12.36 | 1799 | 800 | 2.58 / 1488.86 | 5 | 27 |
4 | 13 | 1854.84 | 36 | 12.63 | 1729 | 786 | 3.36 / 1489.65 | 5 | 31 |
5 | 13 | 1333.04 | 36 | 13.33 | 1368 | 656 | 4.02 / 1490.31 | 5 | 38 |
6 | 13 | 811.64 | 36 | 13.63 | 991 | 486 | 4.51 / 1490.79 | 5 | 46 |
7 | 13 | 272.76 | 36 | 14.04 | 536 | 271 | 4.78 / 1491.06 | 5 | 42 |
8 | 13 | 16.80 | 36 | 14.25 | 308 | 158 | 4.93 / 1491.22 | 6 | 33 |
9 | 8 | -0.28 | 450 | 14.30 | 285 | 1834 | 6.77 / 1493.06 | 6 | 60 |
Average= | 64.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.40 | 62 | 14.28 | 354 | 313 | 0.31 / 1479.72 | 6 | 7 |
2 | 7 | 2004.04 | 105 | 7.94 | 1759 | 1466 | 1.78 / 1481.19 | 7 | 8 |
3 | 13 | 1941.92 | 36 | 12.38 | 1796 | 800 | 2.58 / 1481.99 | 5 | 28 |
4 | 13 | 1845.28 | 36 | 12.66 | 1730 | 788 | 3.37 / 1482.78 | 5 | 33 |
5 | 13 | 1419.24 | 36 | 13.27 | 1428 | 682 | 4.05 / 1483.46 | 5 | 39 |
6 | 13 | 879.52 | 36 | 13.59 | 1041 | 509 | 4.56 / 1483.97 | 5 | 46 |
7 | 13 | 342.28 | 36 | 13.97 | 599 | 301 | 4.86 / 1484.27 | 5 | 45 |
8 | 13 | 23.92 | 36 | 14.25 | 319 | 164 | 5.03 / 1484.44 | 6 | 34 |
9 | 8 | -0.24 | 450 | 14.28 | 288 | 1851 | 6.88 / 1486.29 | 6 | 62 |
Average= | 67.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.32 | 62 | 14.31 | 345 | 306 | 0.31 / 1473.08 | 6 | 7 |
2 | 7 | 2007.84 | 105 | 8.03 | 1765 | 1488 | 1.79 / 1474.56 | 7 | 8 |
3 | 13 | 1940.76 | 36 | 12.43 | 1787 | 800 | 2.59 / 1475.36 | 5 | 27 |
4 | 13 | 1843.92 | 36 | 12.70 | 1723 | 788 | 3.38 / 1476.15 | 5 | 31 |
5 | 13 | 1319.04 | 36 | 13.34 | 1357 | 652 | 4.03 / 1476.80 | 5 | 40 |
6 | 13 | 896.80 | 36 | 13.58 | 1045 | 511 | 4.54 / 1477.31 | 5 | 45 |
7 | 13 | 237.32 | 36 | 14.06 | 501 | 254 | 4.80 / 1477.57 | 5 | 43 |
8 | 8 | -0.12 | 450 | 14.28 | 287 | 1844 | 6.64 / 1479.41 | 6 | 52 |
Average= | 70.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.52 | 62 | 14.28 | 356 | 315 | 0.32 / 1466.38 | 6 | 7 |
2 | 7 | 2009.44 | 106 | 8.06 | 1764 | 1507 | 1.82 / 1467.88 | 7 | 8 |
3 | 13 | 1956.16 | 36 | 12.42 | 1803 | 806 | 2.63 / 1468.69 | 5 | 29 |
4 | 13 | 1867.92 | 36 | 12.70 | 1744 | 797 | 3.43 / 1469.49 | 5 | 32 |
5 | 13 | 1338.68 | 36 | 13.33 | 1362 | 654 | 4.08 / 1470.14 | 5 | 39 |
6 | 13 | 916.76 | 36 | 13.56 | 1060 | 517 | 4.60 / 1470.66 | 5 | 44 |
7 | 13 | 270.08 | 36 | 14.02 | 531 | 268 | 4.86 / 1470.93 | 5 | 42 |
8 | 8 | -0.20 | 450 | 14.27 | 287 | 1843 | 6.71 / 1472.77 | 6 | 55 |
Average= | 73.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.68 | 62 | 14.28 | 359 | 318 | 0.32 / 1459.70 | 6 | 7 |
2 | 7 | 2003.56 | 105 | 7.98 | 1764 | 1478 | 1.80 / 1461.18 | 7 | 8 |
3 | 13 | 1941.20 | 36 | 12.44 | 1791 | 802 | 2.60 / 1461.98 | 5 | 29 |
4 | 13 | 1847.88 | 36 | 12.72 | 1730 | 792 | 3.39 / 1462.77 | 5 | 34 |
5 | 13 | 1425.12 | 36 | 13.28 | 1430 | 684 | 4.07 / 1463.46 | 5 | 39 |
6 | 13 | 870.92 | 36 | 13.59 | 1027 | 502 | 4.58 / 1463.96 | 5 | 45 |
7 | 13 | 234.00 | 36 | 14.05 | 501 | 253 | 4.83 / 1464.21 | 5 | 39 |
8 | 8 | -0.12 | 450 | 14.26 | 288 | 1848 | 6.68 / 1466.06 | 6 | 56 |
Average= | 77.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.32 | 62 | 14.30 | 353 | 313 | 0.31 / 1453.03 | 6 | 7 |
2 | 7 | 2004.52 | 105 | 7.95 | 1767 | 1475 | 1.79 / 1454.50 | 7 | 9 |
3 | 13 | 1948.28 | 36 | 12.45 | 1798 | 806 | 2.59 / 1455.31 | 5 | 29 |
4 | 13 | 1858.36 | 36 | 12.73 | 1737 | 796 | 3.39 / 1456.10 | 5 | 33 |
5 | 13 | 1426.92 | 36 | 13.27 | 1438 | 687 | 4.08 / 1456.79 | 5 | 39 |
6 | 13 | 893.08 | 36 | 13.57 | 1047 | 511 | 4.59 / 1457.30 | 5 | 45 |
7 | 13 | 154.28 | 36 | 14.12 | 434 | 221 | 4.81 / 1457.52 | 6 | 40 |
8 | 8 | -0.04 | 450 | 14.26 | 290 | 1861 | 6.67 / 1459.38 | 6 | 58 |
Average= | 81.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.96 | 61 | 14.25 | 363 | 316 | 0.32 / 1446.32 | 6 | 7 |
2 | 7 | 2013.60 | 106 | 7.91 | 1762 | 1477 | 1.79 / 1447.80 | 5 | 8 |
3 | 13 | 1946.84 | 36 | 12.50 | 1794 | 807 | 2.60 / 1448.61 | 5 | 29 |
4 | 13 | 1851.48 | 36 | 12.78 | 1728 | 795 | 3.40 / 1449.40 | 5 | 32 |
5 | 13 | 1428.60 | 36 | 13.28 | 1433 | 685 | 4.08 / 1450.09 | 5 | 38 |
6 | 13 | 898.88 | 36 | 13.57 | 1055 | 515 | 4.60 / 1450.60 | 5 | 45 |
7 | 13 | 255.88 | 36 | 14.02 | 522 | 263 | 4.86 / 1450.87 | 5 | 44 |
8 | 8 | -0.12 | 450 | 14.26 | 288 | 1848 | 6.71 / 1452.71 | 6 | 60 |
Average= | 85.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.76 | 61 | 14.26 | 354 | 308 | 0.31 / 1439.59 | 6 | 6 |
2 | 7 | 2015.96 | 105 | 7.87 | 1762 | 1456 | 1.76 / 1441.05 | 6 | 8 |
3 | 13 | 1956.08 | 36 | 12.45 | 1802 | 808 | 2.57 / 1441.86 | 5 | 28 |
4 | 13 | 1863.44 | 36 | 12.73 | 1744 | 799 | 3.37 / 1442.66 | 5 | 33 |
5 | 13 | 1342.32 | 36 | 13.32 | 1373 | 658 | 4.03 / 1443.31 | 5 | 40 |
6 | 13 | 925.12 | 36 | 13.54 | 1073 | 523 | 4.55 / 1443.84 | 5 | 44 |
7 | 13 | 374.68 | 36 | 13.91 | 627 | 314 | 4.87 / 1444.15 | 5 | 46 |
8 | 8 | 0.00 | 450 | 14.26 | 289 | 1855 | 6.72 / 1446.01 | 6 | 54 |
Average= | 90.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.04 | 61 | 14.26 | 356 | 310 | 0.31 / 1432.93 | 6 | 7 |
2 | 7 | 2014.24 | 106 | 7.96 | 1768 | 1492 | 1.80 / 1434.43 | 7 | 8 |
3 | 13 | 1953.04 | 36 | 12.51 | 1795 | 808 | 2.61 / 1435.23 | 5 | 29 |
4 | 13 | 1865.12 | 36 | 12.79 | 1735 | 799 | 3.41 / 1436.03 | 5 | 32 |
5 | 13 | 1426.68 | 36 | 13.27 | 1430 | 683 | 4.09 / 1436.72 | 5 | 39 |
6 | 13 | 798.80 | 36 | 13.63 | 969 | 475 | 4.57 / 1437.19 | 5 | 46 |
7 | 13 | 269.04 | 36 | 14.00 | 525 | 265 | 4.83 / 1437.46 | 5 | 44 |
8 | 8 | -0.24 | 450 | 14.26 | 285 | 1829 | 6.66 / 1439.29 | 6 | 59 |
Average= | 95.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.32 | 61 | 14.24 | 345 | 300 | 0.30 / 1426.28 | 6 | 6 |
2 | 7 | 2004.12 | 105 | 7.88 | 1756 | 1453 | 1.75 / 1427.73 | 6 | 7 |
3 | 13 | 1945.88 | 36 | 12.48 | 1797 | 807 | 2.56 / 1428.54 | 5 | 28 |
4 | 13 | 1854.20 | 36 | 12.75 | 1735 | 796 | 3.36 / 1429.33 | 5 | 32 |
5 | 13 | 1432.52 | 36 | 13.27 | 1433 | 685 | 4.04 / 1430.02 | 5 | 38 |
6 | 13 | 893.00 | 36 | 13.56 | 1041 | 508 | 4.55 / 1430.52 | 5 | 45 |
7 | 13 | 244.40 | 36 | 14.02 | 512 | 258 | 4.81 / 1430.78 | 5 | 40 |
8 | 8 | -0.12 | 450 | 14.26 | 287 | 1842 | 6.65 / 1432.62 | 6 | 54 |
Average= | 102.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.36 | 61 | 14.20 | 356 | 308 | 0.31 / 1419.50 | 6 | 7 |
2 | 7 | 2003.08 | 105 | 7.98 | 1756 | 1471 | 1.78 / 1420.97 | 7 | 9 |
3 | 13 | 1934.04 | 36 | 12.52 | 1789 | 806 | 2.59 / 1421.78 | 5 | 30 |
4 | 13 | 1838.04 | 36 | 12.80 | 1726 | 795 | 3.38 / 1422.57 | 5 | 35 |
5 | 13 | 1418.92 | 36 | 13.26 | 1429 | 682 | 4.06 / 1423.26 | 5 | 40 |
6 | 13 | 867.16 | 36 | 13.57 | 1027 | 502 | 4.57 / 1423.76 | 5 | 45 |
7 | 13 | 221.72 | 36 | 14.03 | 489 | 247 | 4.81 / 1424.01 | 6 | 42 |
8 | 13 | 7.12 | 36 | 14.24 | 301 | 154 | 4.97 / 1424.16 | 6 | 33 |
9 | 8 | -0.16 | 450 | 14.26 | 283 | 1816 | 6.78 / 1425.98 | 6 | 64 |
Average= | 109.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.04 | 61 | 14.21 | 359 | 311 | 0.31 / 1412.82 | 6 | 7 |
2 | 7 | 2013.56 | 106 | 8.01 | 1767 | 1500 | 1.81 / 1414.32 | 7 | 9 |
3 | 13 | 1949.36 | 36 | 12.51 | 1803 | 812 | 2.62 / 1415.13 | 5 | 29 |
4 | 13 | 1854.48 | 36 | 12.80 | 1733 | 799 | 3.42 / 1415.93 | 5 | 34 |
5 | 13 | 1234.00 | 36 | 13.37 | 1295 | 623 | 4.05 / 1416.56 | 5 | 41 |
6 | 13 | 821.28 | 36 | 13.59 | 993 | 486 | 4.53 / 1417.04 | 5 | 45 |
7 | 13 | 382.00 | 36 | 13.89 | 632 | 316 | 4.85 / 1417.36 | 5 | 46 |
8 | 8 | 0.00 | 450 | 14.26 | 286 | 1835 | 6.68 / 1419.19 | 6 | 63 |
Average= | 118.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.24 | 61 | 14.19 | 356 | 308 | 0.31 / 1406.07 | 6 | 7 |
2 | 7 | 2016.32 | 105 | 8.03 | 1768 | 1491 | 1.80 / 1407.56 | 7 | 9 |
3 | 13 | 1951.48 | 36 | 12.54 | 1800 | 813 | 2.61 / 1408.37 | 5 | 29 |
4 | 13 | 1756.64 | 36 | 12.99 | 1667 | 780 | 3.39 / 1409.15 | 5 | 36 |
5 | 13 | 1436.76 | 36 | 13.26 | 1441 | 688 | 4.08 / 1409.84 | 5 | 39 |
6 | 13 | 988.44 | 36 | 13.51 | 1116 | 543 | 4.62 / 1410.38 | 5 | 45 |
7 | 13 | 317.28 | 36 | 13.95 | 575 | 289 | 4.91 / 1410.67 | 5 | 43 |
8 | 8 | -0.04 | 450 | 14.26 | 287 | 1842 | 6.75 / 1412.51 | 6 | 50 |
Average= | 128.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.56 | 61 | 14.19 | 362 | 313 | 0.31 / 1399.41 | 6 | 7 |
2 | 7 | 2005.44 | 105 | 8.11 | 1765 | 1503 | 1.82 / 1400.91 | 7 | 11 |
3 | 13 | 1941.36 | 36 | 12.55 | 1801 | 814 | 2.63 / 1401.72 | 5 | 31 |
4 | 13 | 1844.52 | 36 | 12.82 | 1731 | 799 | 3.43 / 1402.52 | 5 | 34 |
5 | 13 | 1231.80 | 36 | 13.37 | 1298 | 625 | 4.05 / 1403.15 | 5 | 42 |
6 | 13 | 815.96 | 36 | 13.58 | 994 | 486 | 4.54 / 1403.63 | 5 | 45 |
7 | 13 | 274.08 | 36 | 13.97 | 541 | 272 | 4.81 / 1403.91 | 5 | 43 |
8 | 8 | 0.00 | 450 | 14.25 | 289 | 1853 | 6.66 / 1405.76 | 6 | 59 |
Average= | 140.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.00 | 61 | 14.18 | 358 | 310 | 0.31 / 1392.73 | 6 | 7 |
2 | 7 | 2005.20 | 105 | 8.17 | 1759 | 1509 | 1.82 / 1394.24 | 7 | 11 |
3 | 13 | 1933.80 | 36 | 12.60 | 1789 | 811 | 2.63 / 1395.05 | 5 | 31 |
4 | 13 | 1839.88 | 36 | 12.86 | 1719 | 796 | 3.43 / 1395.85 | 5 | 34 |
5 | 13 | 1408.92 | 36 | 13.27 | 1417 | 677 | 4.10 / 1396.52 | 5 | 39 |
6 | 13 | 772.40 | 36 | 13.61 | 954 | 467 | 4.57 / 1396.99 | 5 | 47 |
7 | 13 | 229.64 | 36 | 14.01 | 494 | 249 | 4.82 / 1397.24 | 5 | 39 |
8 | 8 | -0.04 | 450 | 14.25 | 289 | 1853 | 6.67 / 1399.09 | 6 | 55 |
Average= | 155.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.16 | 61 | 14.22 | 353 | 306 | 0.31 / 1386.00 | 6 | 7 |
2 | 7 | 2015.36 | 105 | 8.22 | 1771 | 1529 | 1.83 / 1387.53 | 7 | 11 |
3 | 13 | 1947.00 | 36 | 12.60 | 1805 | 819 | 2.65 / 1388.35 | 5 | 31 |
4 | 13 | 1849.76 | 36 | 12.85 | 1738 | 804 | 3.46 / 1389.15 | 5 | 36 |
5 | 13 | 1420.48 | 36 | 13.27 | 1435 | 686 | 4.14 / 1389.84 | 5 | 40 |
6 | 13 | 778.88 | 36 | 13.61 | 965 | 473 | 4.62 / 1390.31 | 5 | 46 |
7 | 13 | 240.80 | 36 | 14.00 | 510 | 257 | 4.87 / 1390.57 | 5 | 43 |
8 | 8 | -0.28 | 450 | 14.24 | 289 | 1852 | 6.72 / 1392.42 | 6 | 52 |
Average= | 174.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.96 | 61 | 14.20 | 356 | 308 | 0.31 / 1379.28 | 6 | 8 |
2 | 7 | 2003.68 | 105 | 8.39 | 1760 | 1550 | 1.86 / 1380.83 | 5 | 8 |
3 | 13 | 1940.08 | 36 | 12.62 | 1797 | 816 | 2.68 / 1381.65 | 5 | 29 |
4 | 13 | 1848.00 | 36 | 12.85 | 1735 | 803 | 3.48 / 1382.45 | 5 | 33 |
5 | 13 | 1312.40 | 36 | 13.32 | 1354 | 649 | 4.13 / 1383.10 | 5 | 39 |
6 | 13 | 784.16 | 36 | 13.59 | 970 | 475 | 4.60 / 1383.58 | 5 | 46 |
7 | 13 | 236.80 | 36 | 13.99 | 505 | 254 | 4.86 / 1383.83 | 5 | 40 |
8 | 8 | -0.12 | 450 | 14.24 | 291 | 1865 | 6.72 / 1385.70 | 6 | 57 |
Average= | 197.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.68 | 61 | 14.18 | 359 | 311 | 0.31 / 1372.68 | 6 | 7 |
2 | 7 | 2011.68 | 105 | 8.36 | 1767 | 1551 | 1.86 / 1374.23 | 7 | 11 |
3 | 13 | 1933.64 | 36 | 12.64 | 1792 | 815 | 2.68 / 1375.05 | 5 | 31 |
4 | 13 | 1739.56 | 36 | 13.02 | 1656 | 776 | 3.45 / 1375.83 | 5 | 36 |
5 | 13 | 1218.16 | 36 | 13.37 | 1283 | 618 | 4.07 / 1376.44 | 5 | 41 |
6 | 13 | 697.92 | 36 | 13.65 | 898 | 441 | 4.51 / 1376.89 | 5 | 47 |
7 | 13 | 166.72 | 36 | 14.06 | 443 | 224 | 4.74 / 1377.11 | 6 | 40 |
8 | 8 | -0.12 | 450 | 14.25 | 291 | 1866 | 6.60 / 1378.98 | 6 | 54 |
Average= | 229.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.24 | 61 | 14.17 | 360 | 311 | 0.31 / 1366.03 | 6 | 9 |
2 | 7 | 2016.16 | 105 | 8.42 | 1774 | 1568 | 1.88 / 1367.60 | 9 | 8 |
3 | 13 | 1944.64 | 36 | 12.66 | 1803 | 822 | 2.70 / 1368.42 | 5 | 29 |
4 | 13 | 1756.24 | 36 | 13.02 | 1674 | 785 | 3.49 / 1369.21 | 5 | 34 |
5 | 13 | 1239.84 | 36 | 13.36 | 1306 | 628 | 4.11 / 1369.83 | 5 | 42 |
6 | 13 | 725.76 | 36 | 13.63 | 925 | 454 | 4.57 / 1370.29 | 5 | 47 |
7 | 13 | 181.68 | 36 | 14.06 | 454 | 230 | 4.80 / 1370.52 | 6 | 40 |
8 | 8 | -0.04 | 450 | 14.26 | 289 | 1855 | 6.65 / 1372.37 | 6 | 61 |
Average= | 274.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.52 | 61 | 14.21 | 358 | 310 | 0.31 / 1359.23 | 6 | 8 |
2 | 7 | 2013.76 | 105 | 8.53 | 1778 | 1592 | 1.90 / 1360.82 | 8 | 11 |
3 | 13 | 1940.24 | 36 | 12.68 | 1796 | 820 | 2.72 / 1361.64 | 5 | 28 |
4 | 13 | 1842.56 | 36 | 12.90 | 1730 | 803 | 3.53 / 1362.45 | 5 | 33 |
5 | 13 | 1306.48 | 36 | 13.33 | 1346 | 646 | 4.17 / 1363.09 | 5 | 39 |
6 | 13 | 871.88 | 36 | 13.54 | 1034 | 504 | 4.68 / 1363.60 | 5 | 47 |
7 | 13 | 201.48 | 36 | 14.03 | 474 | 239 | 4.92 / 1363.84 | 6 | 40 |
8 | 8 | -0.12 | 450 | 14.25 | 294 | 1885 | 6.80 / 1365.72 | 6 | 60 |
Average= | 341.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.48 | 61 | 14.18 | 366 | 317 | 0.32 / 1352.50 | 6 | 8 |
2 | 7 | 2013.48 | 105 | 8.62 | 1777 | 1608 | 1.92 / 1354.11 | 8 | 9 |
3 | 13 | 1941.00 | 36 | 12.69 | 1793 | 819 | 2.74 / 1354.93 | 5 | 28 |
4 | 13 | 1844.84 | 36 | 12.90 | 1728 | 802 | 3.55 / 1355.73 | 5 | 32 |
5 | 13 | 1211.72 | 36 | 13.38 | 1281 | 617 | 4.16 / 1356.35 | 5 | 42 |
6 | 13 | 780.28 | 36 | 13.59 | 962 | 471 | 4.63 / 1356.82 | 5 | 47 |
7 | 13 | 236.04 | 36 | 13.99 | 508 | 256 | 4.89 / 1357.07 | 5 | 42 |
8 | 8 | -0.08 | 450 | 14.26 | 288 | 1848 | 6.74 / 1358.92 | 6 | 52 |
Average= | 452.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.72 | 61 | 14.21 | 357 | 309 | 0.31 / 1345.71 | 6 | 6 |
2 | 7 | 2017.04 | 106 | 8.75 | 1778 | 1649 | 1.96 / 1347.36 | 6 | 12 |
3 | 13 | 1945.24 | 36 | 12.70 | 1803 | 824 | 2.78 / 1348.19 | 5 | 32 |
4 | 13 | 1846.84 | 36 | 12.90 | 1732 | 804 | 3.59 / 1348.99 | 5 | 34 |
5 | 13 | 1201.60 | 36 | 13.38 | 1270 | 612 | 4.20 / 1349.60 | 5 | 41 |
6 | 13 | 779.44 | 36 | 13.58 | 967 | 473 | 4.67 / 1350.07 | 5 | 46 |
7 | 13 | 220.12 | 36 | 14.01 | 492 | 248 | 4.92 / 1350.32 | 6 | 42 |
8 | 8 | -0.04 | 450 | 14.25 | 290 | 1860 | 6.78 / 1352.18 | 6 | 61 |
Average= | 676.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.88 | 61 | 14.21 | 353 | 306 | 0.31 / 1339.02 | 6 | 6 |
2 | 7 | 2014.64 | 105 | 8.83 | 1779 | 1649 | 1.96 / 1340.67 | 6 | 13 |
3 | 13 | 1942.68 | 36 | 12.72 | 1798 | 823 | 2.78 / 1341.49 | 5 | 31 |
4 | 13 | 1847.76 | 36 | 12.91 | 1734 | 806 | 3.58 / 1342.30 | 5 | 33 |
5 | 13 | 1312.68 | 36 | 13.32 | 1353 | 649 | 4.23 / 1342.95 | 5 | 40 |
6 | 13 | 672.40 | 36 | 13.65 | 879 | 432 | 4.67 / 1343.38 | 5 | 46 |
7 | 13 | 70.16 | 36 | 14.19 | 355 | 181 | 4.85 / 1343.56 | 6 | 35 |
8 | 8 | 0.04 | 450 | 14.27 | 287 | 1843 | 6.69 / 1345.40 | 6 | 53 |
Average= | 1345.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.12 | 61 | 14.24 | 361 | 314 | 0.31 / 1332.26 | 6 | 6 |
2 | 7 | 2003.80 | 105 | 8.99 | 1775 | 1676 | 1.99 / 1333.93 | 6 | 14 |
3 | 13 | 1928.00 | 36 | 12.76 | 1791 | 823 | 2.81 / 1334.76 | 5 | 32 |
4 | 13 | 1733.92 | 36 | 13.04 | 1655 | 777 | 3.59 / 1335.53 | 5 | 34 |
5 | 13 | 1284.64 | 36 | 13.33 | 1336 | 641 | 4.23 / 1336.17 | 5 | 41 |
6 | 13 | 739.20 | 36 | 13.61 | 932 | 457 | 4.69 / 1336.63 | 5 | 47 |
7 | 13 | 171.96 | 36 | 14.05 | 449 | 227 | 4.91 / 1336.86 | 6 | 39 |
8 | 8 | -0.08 | 450 | 14.26 | 289 | 1855 | 6.77 / 1338.71 | 6 | 61 |
Average= | 6.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.32 | 61 | 14.25 | 354 | 308 | 0.31 / 1325.50 | 6 | 6 |
2 | 7 | 2003.40 | 106 | 9.03 | 1783 | 1707 | 2.01 / 1327.20 | 6 | 13 |
3 | 13 | 1930.16 | 36 | 12.76 | 1791 | 823 | 2.84 / 1328.03 | 5 | 32 |
4 | 13 | 1728.52 | 36 | 13.06 | 1649 | 775 | 3.61 / 1328.80 | 5 | 35 |
5 | 13 | 1296.68 | 36 | 13.33 | 1339 | 643 | 4.25 / 1329.44 | 5 | 41 |
6 | 13 | 742.48 | 36 | 13.60 | 935 | 458 | 4.71 / 1329.90 | 5 | 46 |
7 | 13 | 92.00 | 36 | 14.15 | 376 | 192 | 4.90 / 1330.09 | 6 | 37 |
8 | 8 | -0.16 | 450 | 14.28 | 288 | 1851 | 6.75 / 1331.94 | 6 | 55 |
Average= | 6.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.56 | 61 | 14.25 | 351 | 305 | 0.31 / 1318.60 | 6 | 6 |
2 | 7 | 2016.24 | 105 | 9.05 | 1782 | 1693 | 2.00 / 1320.29 | 6 | 14 |
3 | 13 | 1945.52 | 36 | 12.77 | 1797 | 826 | 2.82 / 1321.12 | 5 | 32 |
4 | 13 | 1847.64 | 36 | 12.94 | 1734 | 808 | 3.63 / 1321.93 | 5 | 34 |
5 | 13 | 1176.36 | 36 | 13.38 | 1258 | 606 | 4.24 / 1322.53 | 5 | 42 |
6 | 13 | 746.96 | 36 | 13.60 | 940 | 460 | 4.70 / 1322.99 | 5 | 47 |
7 | 13 | 93.52 | 36 | 14.16 | 380 | 194 | 4.89 / 1323.19 | 6 | 38 |
8 | 13 | 19.48 | 36 | 14.25 | 312 | 160 | 5.05 / 1323.35 | 6 | 36 |
9 | 8 | -0.08 | 450 | 14.28 | 287 | 1844 | 6.90 / 1325.19 | 6 | 60 |
Average= | 6.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.36 | 61 | 14.28 | 345 | 301 | 0.30 / 1311.84 | 6 | 6 |
2 | 7 | 2007.80 | 105 | 9.16 | 1781 | 1713 | 2.01 / 1313.55 | 6 | 14 |
3 | 13 | 1937.72 | 36 | 12.78 | 1797 | 827 | 2.84 / 1314.38 | 5 | 32 |
4 | 13 | 1632.16 | 36 | 13.12 | 1582 | 747 | 3.59 / 1315.12 | 5 | 36 |
5 | 13 | 1009.68 | 36 | 13.46 | 1138 | 551 | 4.14 / 1315.68 | 5 | 43 |
6 | 13 | 701.52 | 36 | 13.62 | 902 | 442 | 4.58 / 1316.12 | 5 | 47 |
7 | 13 | 74.00 | 36 | 14.18 | 358 | 183 | 4.76 / 1316.30 | 6 | 36 |
8 | 13 | 18.80 | 36 | 14.26 | 310 | 159 | 4.92 / 1316.46 | 6 | 35 |
9 | 8 | -0.36 | 450 | 14.29 | 285 | 1833 | 6.76 / 1318.29 | 6 | 65 |
Average= | 6.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.04 | 61 | 14.27 | 345 | 300 | 0.30 / 1305.13 | 6 | 7 |
2 | 7 | 2011.36 | 106 | 9.21 | 1781 | 1739 | 2.04 / 1306.87 | 7 | 15 |
3 | 13 | 1942.76 | 36 | 12.80 | 1793 | 826 | 2.87 / 1307.70 | 5 | 33 |
4 | 13 | 1745.20 | 36 | 13.05 | 1660 | 780 | 3.65 / 1308.48 | 5 | 36 |
5 | 13 | 1123.88 | 36 | 13.40 | 1216 | 587 | 4.23 / 1309.07 | 5 | 41 |
6 | 13 | 695.96 | 36 | 13.62 | 896 | 439 | 4.67 / 1309.50 | 5 | 46 |
7 | 13 | 67.48 | 36 | 14.19 | 354 | 181 | 4.85 / 1309.69 | 6 | 38 |
8 | 8 | -0.20 | 450 | 14.29 | 288 | 1852 | 6.70 / 1311.54 | 6 | 54 |
Average= | 6.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.92 | 61 | 14.25 | 352 | 306 | 0.31 / 1298.51 | 6 | 8 |
2 | 7 | 2008.08 | 105 | 9.31 | 1785 | 1745 | 2.05 / 1300.25 | 8 | 17 |
3 | 13 | 1938.44 | 36 | 12.79 | 1793 | 826 | 2.88 / 1301.08 | 5 | 34 |
4 | 13 | 1635.52 | 36 | 13.13 | 1582 | 748 | 3.62 / 1301.83 | 5 | 36 |
5 | 13 | 1207.40 | 36 | 13.37 | 1277 | 615 | 4.24 / 1302.44 | 5 | 42 |
6 | 13 | 559.92 | 36 | 13.71 | 785 | 387 | 4.63 / 1302.83 | 5 | 48 |
7 | 13 | 64.76 | 36 | 14.20 | 348 | 178 | 4.80 / 1303.01 | 6 | 36 |
8 | 8 | -0.12 | 450 | 14.29 | 284 | 1826 | 6.63 / 1304.83 | 6 | 55 |
Average= | 6.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.52 | 61 | 14.28 | 341 | 297 | 0.30 / 1291.83 | 6 | 7 |
2 | 7 | 2011.52 | 105 | 9.39 | 1784 | 1759 | 2.06 / 1293.59 | 7 | 17 |
3 | 13 | 1937.96 | 36 | 12.80 | 1793 | 826 | 2.88 / 1294.42 | 5 | 31 |
4 | 13 | 1840.72 | 36 | 12.97 | 1722 | 804 | 3.69 / 1295.22 | 5 | 34 |
5 | 13 | 1094.36 | 36 | 13.43 | 1193 | 577 | 4.26 / 1295.80 | 5 | 43 |
6 | 13 | 569.40 | 36 | 13.70 | 787 | 388 | 4.65 / 1296.19 | 5 | 48 |
7 | 13 | 63.72 | 36 | 14.20 | 345 | 176 | 4.83 / 1296.37 | 6 | 35 |
8 | 8 | -0.28 | 450 | 14.28 | 286 | 1838 | 6.67 / 1298.20 | 6 | 51 |
Average= | 6.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.24 | 61 | 14.29 | 351 | 306 | 0.31 / 1285.17 | 6 | 7 |
2 | 7 | 2005.32 | 105 | 9.43 | 1782 | 1764 | 2.07 / 1286.94 | 7 | 16 |
3 | 13 | 1934.64 | 36 | 12.82 | 1788 | 825 | 2.90 / 1287.76 | 5 | 34 |
4 | 13 | 1633.28 | 36 | 13.13 | 1578 | 746 | 3.64 / 1288.51 | 5 | 37 |
5 | 13 | 1199.28 | 36 | 13.37 | 1264 | 608 | 4.25 / 1289.12 | 5 | 42 |
6 | 13 | 663.68 | 36 | 13.64 | 869 | 427 | 4.68 / 1289.54 | 5 | 47 |
7 | 13 | 59.40 | 36 | 14.22 | 340 | 174 | 4.85 / 1289.72 | 6 | 33 |
8 | 8 | -0.16 | 450 | 14.30 | 283 | 1821 | 6.67 / 1291.54 | 6 | 59 |
Average= | 6.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.48 | 61 | 14.29 | 343 | 299 | 0.30 / 1278.56 | 6 | 7 |
2 | 7 | 2003.32 | 105 | 9.51 | 1787 | 1784 | 2.08 / 1280.35 | 7 | 14 |
3 | 13 | 1926.36 | 36 | 12.83 | 1785 | 824 | 2.91 / 1281.17 | 5 | 32 |
4 | 13 | 1517.88 | 36 | 13.20 | 1499 | 712 | 3.62 / 1281.88 | 5 | 38 |
5 | 13 | 1103.04 | 36 | 13.42 | 1196 | 578 | 4.20 / 1282.46 | 5 | 43 |
6 | 13 | 570.36 | 36 | 13.70 | 793 | 391 | 4.59 / 1282.85 | 5 | 49 |
7 | 13 | 60.40 | 36 | 14.20 | 343 | 175 | 4.76 / 1283.03 | 6 | 37 |
8 | 8 | -0.24 | 450 | 14.29 | 286 | 1839 | 6.60 / 1284.87 | 6 | 47 |
Average= | 6.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.96 | 61 | 14.27 | 350 | 305 | 0.30 / 1271.92 | 6 | 7 |
2 | 7 | 2006.32 | 106 | 9.60 | 1784 | 1815 | 2.12 / 1273.74 | 7 | 17 |
3 | 13 | 1932.04 | 36 | 12.82 | 1798 | 830 | 2.95 / 1274.57 | 5 | 33 |
4 | 13 | 1537.24 | 36 | 13.19 | 1514 | 719 | 3.67 / 1275.29 | 5 | 37 |
5 | 13 | 1119.96 | 36 | 13.41 | 1207 | 583 | 4.25 / 1275.87 | 5 | 42 |
6 | 13 | 593.80 | 36 | 13.68 | 814 | 401 | 4.65 / 1276.27 | 5 | 48 |
7 | 13 | 39.68 | 36 | 14.24 | 325 | 167 | 4.82 / 1276.44 | 6 | 34 |
8 | 8 | 0.24 | 450 | 14.29 | 284 | 1826 | 6.65 / 1278.26 | 6 | 60 |
Average= | 6.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.68 | 61 | 14.29 | 344 | 300 | 0.30 / 1265.02 | 6 | 8 |
2 | 7 | 2004.56 | 106 | 9.59 | 1781 | 1810 | 2.11 / 1266.83 | 8 | 13 |
3 | 13 | 1931.60 | 36 | 12.85 | 1783 | 825 | 2.94 / 1267.65 | 5 | 31 |
4 | 13 | 1853.16 | 36 | 12.98 | 1733 | 810 | 3.74 / 1268.46 | 5 | 34 |
5 | 13 | 1288.44 | 36 | 13.33 | 1335 | 641 | 4.39 / 1269.11 | 5 | 41 |
6 | 13 | 532.56 | 36 | 13.73 | 760 | 376 | 4.76 / 1269.48 | 5 | 48 |
7 | 13 | 48.24 | 36 | 14.21 | 341 | 174 | 4.94 / 1269.66 | 6 | 37 |
8 | 13 | 25.80 | 36 | 14.25 | 315 | 162 | 5.10 / 1269.82 | 6 | 37 |
9 | 8 | -0.28 | 450 | 14.29 | 280 | 1801 | 6.90 / 1271.62 | 6 | 59 |
Average= | 6.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.96 | 61 | 14.26 | 340 | 296 | 0.30 / 1258.40 | 6 | 7 |
2 | 7 | 2004.68 | 106 | 9.70 | 1783 | 1833 | 2.13 / 1260.23 | 7 | 17 |
3 | 13 | 1920.16 | 36 | 12.84 | 1777 | 821 | 2.95 / 1261.05 | 5 | 34 |
4 | 13 | 1509.92 | 36 | 13.21 | 1486 | 707 | 3.66 / 1261.76 | 5 | 37 |
5 | 13 | 1087.44 | 36 | 13.42 | 1183 | 572 | 4.23 / 1262.33 | 5 | 43 |
6 | 13 | 657.32 | 36 | 13.65 | 858 | 422 | 4.65 / 1262.75 | 5 | 49 |
7 | 13 | 45.40 | 36 | 14.23 | 326 | 167 | 4.82 / 1262.92 | 6 | 36 |
8 | 8 | -0.28 | 450 | 14.29 | 280 | 1801 | 6.62 / 1264.72 | 6 | 59 |
Average= | 6.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.08 | 61 | 14.26 | 347 | 302 | 0.30 / 1251.74 | 6 | 6 |
2 | 7 | 2004.04 | 106 | 9.73 | 1790 | 1846 | 2.15 / 1253.59 | 5 | 17 |
3 | 13 | 1923.44 | 36 | 12.87 | 1781 | 825 | 2.97 / 1254.41 | 5 | 34 |
4 | 13 | 1618.80 | 36 | 13.16 | 1566 | 742 | 3.72 / 1255.16 | 5 | 36 |
5 | 13 | 1180.24 | 36 | 13.38 | 1253 | 604 | 4.32 / 1255.76 | 5 | 44 |
6 | 13 | 522.88 | 36 | 13.73 | 752 | 372 | 4.69 / 1256.13 | 5 | 48 |
7 | 13 | 45.04 | 36 | 14.23 | 330 | 169 | 4.86 / 1256.30 | 6 | 35 |
8 | 8 | -0.24 | 450 | 14.30 | 280 | 1802 | 6.66 / 1258.10 | 6 | 55 |
Average= | 6.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.04 | 61 | 14.25 | 345 | 300 | 0.30 / 1245.10 | 6 | 7 |
2 | 7 | 2004.84 | 105 | 9.75 | 1791 | 1834 | 2.13 / 1246.93 | 7 | 19 |
3 | 13 | 1925.16 | 36 | 12.86 | 1782 | 825 | 2.96 / 1247.75 | 5 | 36 |
4 | 13 | 1516.64 | 36 | 13.21 | 1498 | 712 | 3.67 / 1248.47 | 5 | 38 |
5 | 13 | 1098.64 | 36 | 13.41 | 1198 | 578 | 4.25 / 1249.05 | 5 | 44 |
6 | 13 | 657.40 | 36 | 13.64 | 867 | 426 | 4.67 / 1249.47 | 5 | 47 |
7 | 13 | 25.16 | 36 | 14.26 | 316 | 162 | 4.84 / 1249.63 | 6 | 33 |
8 | 8 | -0.20 | 450 | 14.29 | 281 | 1807 | 6.64 / 1251.44 | 6 | 61 |
Average= | 6.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.56 | 61 | 14.25 | 341 | 296 | 0.30 / 1238.40 | 6 | 6 |
2 | 7 | 2014.88 | 105 | 9.84 | 1794 | 1854 | 2.15 / 1240.26 | 6 | 17 |
3 | 13 | 1926.44 | 36 | 12.86 | 1785 | 826 | 2.98 / 1241.08 | 5 | 33 |
4 | 13 | 1627.52 | 36 | 13.14 | 1572 | 744 | 3.72 / 1241.83 | 5 | 39 |
5 | 13 | 1086.16 | 36 | 13.41 | 1185 | 572 | 4.29 / 1242.40 | 5 | 44 |
6 | 13 | 651.84 | 36 | 13.64 | 861 | 423 | 4.71 / 1242.82 | 5 | 47 |
7 | 13 | 42.92 | 36 | 14.23 | 332 | 170 | 4.88 / 1242.99 | 6 | 36 |
8 | 8 | -0.12 | 450 | 14.28 | 281 | 1806 | 6.69 / 1244.80 | 6 | 56 |
Average= | 6.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.00 | 61 | 14.26 | 345 | 300 | 0.30 / 1231.72 | 6 | 6 |
2 | 7 | 2014.16 | 106 | 9.88 | 1804 | 1889 | 2.19 / 1233.61 | 6 | 18 |
3 | 13 | 1929.84 | 36 | 12.86 | 1781 | 825 | 3.01 / 1234.44 | 5 | 34 |
4 | 13 | 1728.64 | 36 | 13.08 | 1641 | 773 | 3.79 / 1235.21 | 5 | 38 |
5 | 13 | 1170.92 | 36 | 13.38 | 1248 | 601 | 4.39 / 1235.81 | 5 | 44 |
6 | 13 | 434.48 | 36 | 13.80 | 675 | 335 | 4.72 / 1236.15 | 5 | 46 |
7 | 13 | 28.16 | 36 | 14.25 | 310 | 159 | 4.88 / 1236.31 | 6 | 35 |
8 | 8 | -0.20 | 450 | 14.28 | 280 | 1799 | 6.68 / 1238.11 | 6 | 63 |
Average= | 6.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.40 | 61 | 14.25 | 339 | 295 | 0.29 / 1225.16 | 6 | 6 |
2 | 7 | 2007.68 | 105 | 9.90 | 1792 | 1863 | 2.16 / 1227.02 | 6 | 18 |
3 | 13 | 1925.20 | 36 | 12.88 | 1774 | 823 | 2.98 / 1227.85 | 5 | 35 |
4 | 13 | 1617.28 | 36 | 13.16 | 1562 | 740 | 3.72 / 1228.59 | 5 | 38 |
5 | 13 | 983.32 | 36 | 13.47 | 1107 | 537 | 4.26 / 1229.12 | 5 | 45 |
6 | 13 | 459.28 | 36 | 13.79 | 688 | 342 | 4.60 / 1229.46 | 5 | 47 |
7 | 13 | 30.12 | 36 | 14.25 | 314 | 161 | 4.76 / 1229.63 | 6 | 34 |
8 | 8 | -0.32 | 450 | 14.28 | 280 | 1799 | 6.56 / 1231.42 | 6 | 63 |
Average= | 6.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.36 | 61 | 14.27 | 343 | 299 | 0.30 / 1218.57 | 6 | 6 |
2 | 7 | 2011.60 | 105 | 9.92 | 1796 | 1871 | 2.17 / 1220.44 | 6 | 17 |
3 | 13 | 1922.00 | 36 | 12.87 | 1782 | 826 | 2.99 / 1221.27 | 5 | 33 |
4 | 13 | 1513.40 | 36 | 13.21 | 1491 | 709 | 3.70 / 1221.98 | 5 | 38 |
5 | 13 | 1093.00 | 36 | 13.42 | 1189 | 574 | 4.28 / 1222.55 | 5 | 43 |
6 | 13 | 542.28 | 36 | 13.72 | 764 | 377 | 4.66 / 1222.93 | 5 | 48 |
7 | 13 | 23.76 | 36 | 14.27 | 306 | 157 | 4.81 / 1223.08 | 6 | 35 |
8 | 8 | -0.12 | 450 | 14.29 | 277 | 1781 | 6.59 / 1224.87 | 6 | 58 |
Average= | 6.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.76 | 61 | 14.27 | 343 | 299 | 0.30 / 1211.91 | 6 | 6 |
2 | 7 | 2015.76 | 105 | 9.97 | 1799 | 1883 | 2.18 / 1213.80 | 6 | 17 |
3 | 13 | 1933.64 | 36 | 12.87 | 1788 | 828 | 3.01 / 1214.62 | 5 | 34 |
4 | 13 | 1730.16 | 36 | 13.09 | 1650 | 778 | 3.79 / 1215.40 | 5 | 36 |
5 | 13 | 1068.48 | 36 | 13.42 | 1172 | 566 | 4.35 / 1215.97 | 5 | 45 |
6 | 13 | 530.80 | 36 | 13.72 | 754 | 372 | 4.73 / 1216.34 | 5 | 49 |
7 | 13 | 21.64 | 36 | 14.27 | 302 | 155 | 4.88 / 1216.50 | 6 | 32 |
8 | 8 | -0.16 | 450 | 14.30 | 276 | 1776 | 6.66 / 1218.27 | 6 | 63 |
Average= | 6.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.08 | 61 | 14.21 | 350 | 303 | 0.30 / 1205.42 | 6 | 6 |
2 | 7 | 2013.36 | 105 | 9.99 | 1799 | 1887 | 2.19 / 1207.31 | 6 | 18 |
3 | 13 | 1928.16 | 36 | 12.87 | 1788 | 828 | 3.02 / 1208.14 | 5 | 34 |
4 | 13 | 1420.00 | 36 | 13.25 | 1426 | 680 | 3.70 / 1208.82 | 5 | 38 |
5 | 13 | 1015.20 | 36 | 13.45 | 1134 | 549 | 4.25 / 1209.37 | 5 | 46 |
6 | 13 | 392.88 | 36 | 13.85 | 635 | 317 | 4.56 / 1209.68 | 5 | 46 |
7 | 13 | 38.40 | 36 | 14.24 | 318 | 163 | 4.73 / 1209.85 | 6 | 34 |
8 | 8 | -0.12 | 450 | 14.28 | 275 | 1767 | 6.49 / 1211.61 | 6 | 61 |
Average= | 6.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.72 | 61 | 14.23 | 349 | 303 | 0.30 / 1198.81 | 6 | 6 |
2 | 7 | 2012.72 | 105 | 9.98 | 1792 | 1878 | 2.18 / 1200.68 | 6 | 17 |
3 | 13 | 1926.12 | 36 | 12.89 | 1775 | 824 | 3.00 / 1201.51 | 5 | 35 |
4 | 13 | 1617.92 | 36 | 13.15 | 1561 | 739 | 3.74 / 1202.25 | 5 | 37 |
5 | 13 | 1083.04 | 36 | 13.41 | 1177 | 568 | 4.31 / 1202.81 | 5 | 44 |
6 | 13 | 451.88 | 36 | 13.79 | 683 | 339 | 4.65 / 1203.15 | 5 | 46 |
7 | 13 | 26.44 | 36 | 14.25 | 313 | 161 | 4.81 / 1203.31 | 6 | 34 |
8 | 8 | -0.20 | 450 | 14.27 | 281 | 1804 | 6.62 / 1205.12 | 6 | 61 |
Average= | 6.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.36 | 61 | 14.22 | 355 | 308 | 0.31 / 1192.18 | 6 | 7 |
2 | 7 | 2013.52 | 105 | 10.07 | 1794 | 1897 | 2.20 / 1194.08 | 7 | 19 |
3 | 13 | 1926.28 | 36 | 12.88 | 1785 | 828 | 3.03 / 1194.91 | 5 | 35 |
4 | 13 | 1511.16 | 36 | 13.20 | 1488 | 707 | 3.74 / 1195.61 | 5 | 38 |
5 | 13 | 1086.24 | 36 | 13.41 | 1184 | 572 | 4.31 / 1196.19 | 5 | 45 |
6 | 13 | 531.20 | 36 | 13.72 | 757 | 374 | 4.69 / 1196.56 | 5 | 48 |
7 | 13 | 40.80 | 36 | 14.24 | 321 | 165 | 4.85 / 1196.72 | 6 | 36 |
8 | 8 | -0.04 | 450 | 14.27 | 277 | 1779 | 6.63 / 1198.50 | 6 | 68 |
Average= | 6.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.40 | 61 | 14.25 | 342 | 297 | 0.30 / 1185.74 | 6 | 8 |
2 | 7 | 2012.56 | 105 | 10.06 | 1797 | 1898 | 2.20 / 1187.64 | 8 | 19 |
3 | 13 | 1921.88 | 36 | 12.88 | 1772 | 822 | 3.02 / 1188.46 | 5 | 36 |
4 | 13 | 1615.48 | 36 | 13.15 | 1560 | 739 | 3.76 / 1189.20 | 5 | 37 |
5 | 13 | 1069.84 | 36 | 13.43 | 1165 | 563 | 4.32 / 1189.76 | 5 | 45 |
6 | 13 | 431.76 | 36 | 13.80 | 663 | 329 | 4.65 / 1190.09 | 5 | 47 |
7 | 8 | -0.28 | 450 | 14.27 | 278 | 1785 | 6.43 / 1191.87 | 6 | 56 |
Average= | 6.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.04 | 61 | 14.20 | 360 | 312 | 0.31 / 1179.30 | 6 | 7 |
2 | 7 | 2006.20 | 106 | 10.09 | 1789 | 1913 | 2.23 / 1181.21 | 5 | 20 |
3 | 13 | 1918.84 | 36 | 12.90 | 1775 | 824 | 3.05 / 1182.03 | 5 | 35 |
4 | 13 | 1716.28 | 36 | 13.09 | 1634 | 770 | 3.82 / 1182.80 | 5 | 36 |
5 | 13 | 960.12 | 36 | 13.47 | 1087 | 527 | 4.35 / 1183.33 | 5 | 46 |
6 | 13 | 446.36 | 36 | 13.79 | 682 | 339 | 4.69 / 1183.67 | 5 | 48 |
7 | 8 | -0.04 | 450 | 14.27 | 276 | 1772 | 6.46 / 1185.44 | 6 | 58 |
Average= | 6.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.84 | 61 | 14.20 | 347 | 301 | 0.30 / 1172.70 | 6 | 7 |
2 | 7 | 2006.36 | 106 | 10.13 | 1789 | 1921 | 2.22 / 1174.62 | 7 | 20 |
3 | 13 | 1930.36 | 36 | 12.89 | 1780 | 826 | 3.05 / 1175.45 | 5 | 35 |
4 | 13 | 1833.80 | 36 | 13.02 | 1710 | 802 | 3.85 / 1176.25 | 5 | 36 |
5 | 13 | 1136.44 | 36 | 13.40 | 1211 | 584 | 4.43 / 1176.84 | 5 | 44 |
6 | 13 | 486.00 | 36 | 13.76 | 712 | 353 | 4.79 / 1177.19 | 5 | 47 |
7 | 8 | -0.04 | 450 | 14.25 | 280 | 1795 | 6.58 / 1178.98 | 6 | 52 |
Average= | 6.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.92 | 61 | 14.22 | 353 | 306 | 0.31 / 1166.27 | 6 | 7 |
2 | 7 | 2004.24 | 106 | 10.17 | 1788 | 1927 | 2.23 / 1168.20 | 7 | 19 |
3 | 13 | 1917.80 | 36 | 12.90 | 1772 | 823 | 3.06 / 1169.02 | 5 | 35 |
4 | 13 | 1502.00 | 36 | 13.22 | 1473 | 701 | 3.76 / 1169.72 | 5 | 38 |
5 | 13 | 1067.48 | 36 | 13.42 | 1165 | 563 | 4.32 / 1170.29 | 5 | 44 |
6 | 13 | 422.56 | 36 | 13.82 | 654 | 325 | 4.65 / 1170.61 | 5 | 46 |
7 | 8 | -0.04 | 450 | 14.25 | 279 | 1789 | 6.43 / 1172.40 | 6 | 59 |
Average= | 6.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.52 | 59 | 14.22 | 362 | 304 | 0.30 / 1159.81 | 6 | 7 |
2 | 3 | 1036.32 | 2 | 13.19 | 1158 | 31 | 0.33 / 1159.84 | 5 | 11 |
3 | 7 | 2005.76 | 105 | 10.17 | 1794 | 1916 | 2.25 / 1161.75 | 11 | 21 |
4 | 13 | 1923.48 | 36 | 12.90 | 1776 | 825 | 3.07 / 1162.58 | 5 | 35 |
5 | 13 | 1609.44 | 36 | 13.16 | 1554 | 736 | 3.81 / 1163.31 | 5 | 37 |
6 | 13 | 957.20 | 36 | 13.47 | 1086 | 527 | 4.34 / 1163.84 | 5 | 45 |
7 | 13 | 436.32 | 36 | 13.79 | 674 | 335 | 4.67 / 1164.18 | 5 | 46 |
8 | 8 | 0.04 | 450 | 14.27 | 279 | 1792 | 6.46 / 1165.97 | 6 | 55 |
Average= | 6.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.56 | 59 | 14.19 | 352 | 295 | 0.29 / 1153.33 | 6 | 7 |
2 | 7 | 2007.16 | 106 | 10.17 | 1791 | 1931 | 2.23 / 1155.26 | 5 | 20 |
3 | 13 | 1931.88 | 36 | 12.88 | 1786 | 828 | 3.05 / 1156.09 | 5 | 35 |
4 | 13 | 1517.92 | 36 | 13.21 | 1489 | 708 | 3.76 / 1156.79 | 5 | 38 |
5 | 13 | 1081.32 | 36 | 13.42 | 1173 | 567 | 4.33 / 1157.36 | 5 | 44 |
6 | 13 | 433.00 | 36 | 13.80 | 670 | 333 | 4.66 / 1157.69 | 5 | 47 |
7 | 8 | 0.12 | 450 | 14.26 | 282 | 1810 | 6.47 / 1159.50 | 6 | 53 |
Average= | 6.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.20 | 59 | 14.23 | 348 | 292 | 0.29 / 1146.85 | 6 | 7 |
2 | 3 | 1010.20 | 1 | 12.86 | 1137 | 15 | 0.31 / 1146.86 | 5 | 5 |
3 | 7 | 2006.04 | 106 | 10.20 | 1789 | 1934 | 2.24 / 1148.80 | 5 | 20 |
4 | 13 | 1916.88 | 36 | 12.91 | 1774 | 824 | 3.07 / 1149.62 | 5 | 36 |
5 | 13 | 1598.12 | 36 | 13.16 | 1549 | 734 | 3.80 / 1150.36 | 5 | 37 |
6 | 13 | 949.36 | 36 | 13.48 | 1076 | 522 | 4.32 / 1150.88 | 5 | 45 |
7 | 13 | 519.12 | 36 | 13.73 | 741 | 366 | 4.69 / 1151.24 | 5 | 48 |
8 | 8 | 0.00 | 450 | 14.25 | 279 | 1789 | 6.48 / 1153.03 | 6 | 60 |
Average= | 6.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.16 | 58 | 14.24 | 347 | 287 | 0.29 / 1140.43 | 6 | 7 |
2 | 3 | 1012.40 | 1 | 12.93 | 1127 | 15 | 0.30 / 1140.45 | 5 | 5 |
3 | 7 | 2004.04 | 106 | 10.20 | 1790 | 1935 | 2.24 / 1142.38 | 5 | 20 |
4 | 13 | 1922.80 | 36 | 12.90 | 1774 | 824 | 3.06 / 1143.21 | 5 | 34 |
5 | 13 | 1512.36 | 36 | 13.20 | 1485 | 706 | 3.77 / 1143.91 | 5 | 39 |
6 | 13 | 975.68 | 36 | 13.46 | 1093 | 530 | 4.30 / 1144.44 | 5 | 45 |
7 | 13 | 444.16 | 36 | 13.79 | 676 | 336 | 4.63 / 1144.78 | 5 | 48 |
8 | 8 | -0.08 | 450 | 14.26 | 277 | 1778 | 6.41 / 1146.56 | 6 | 54 |
Average= | 6.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.64 | 61 | 14.18 | 357 | 309 | 0.31 / 1133.91 | 6 | 7 |
2 | 3 | 962.72 | -1 | 14.18 | 357 | 0 | 0.00 / 1133.91 | 6 | 7 |
3 | 7 | 2003.72 | 105 | 10.19 | 1788 | 1913 | 2.22 / 1135.82 | 7 | 20 |
4 | 13 | 1917.32 | 36 | 12.91 | 1774 | 824 | 3.05 / 1136.65 | 5 | 34 |
5 | 13 | 1410.80 | 36 | 13.25 | 1413 | 674 | 3.72 / 1137.32 | 5 | 39 |
6 | 13 | 983.12 | 36 | 13.46 | 1102 | 534 | 4.25 / 1137.86 | 5 | 45 |
7 | 13 | 461.00 | 36 | 13.77 | 694 | 344 | 4.60 / 1138.20 | 5 | 48 |
8 | 13 | 27.40 | 36 | 14.26 | 306 | 157 | 4.76 / 1138.36 | 6 | 36 |
9 | 8 | -0.04 | 450 | 14.26 | 279 | 1790 | 6.55 / 1140.15 | 6 | 61 |
Average= | 6.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.12 | 61 | 14.26 | 338 | 294 | 0.29 / 1127.31 | 6 | 7 |
2 | 7 | 2005.04 | 105 | 10.21 | 1794 | 1923 | 2.22 / 1129.23 | 7 | 19 |
3 | 13 | 1923.16 | 36 | 12.89 | 1779 | 826 | 3.04 / 1130.06 | 5 | 35 |
4 | 13 | 1513.24 | 36 | 13.20 | 1481 | 704 | 3.75 / 1130.76 | 5 | 39 |
5 | 13 | 1084.32 | 36 | 13.41 | 1177 | 568 | 4.31 / 1131.33 | 5 | 44 |
6 | 13 | 437.32 | 36 | 13.79 | 675 | 335 | 4.65 / 1131.66 | 5 | 47 |
7 | 13 | 4.88 | 36 | 14.30 | 291 | 150 | 4.80 / 1131.81 | 6 | 39 |
8 | 8 | -0.08 | 450 | 14.25 | 279 | 1789 | 6.59 / 1133.60 | 6 | 54 |
Average= | 6.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.72 | 61 | 14.23 | 349 | 303 | 0.30 / 1120.93 | 6 | 6 |
2 | 7 | 2012.72 | 105 | 10.20 | 1794 | 1921 | 2.22 / 1122.85 | 6 | 18 |
3 | 13 | 1924.40 | 36 | 12.90 | 1780 | 827 | 3.05 / 1123.68 | 5 | 34 |
4 | 13 | 1418.04 | 36 | 13.25 | 1404 | 670 | 3.72 / 1124.35 | 5 | 39 |
5 | 13 | 1010.72 | 36 | 13.44 | 1124 | 544 | 4.26 / 1124.89 | 5 | 43 |
6 | 13 | 471.44 | 36 | 13.77 | 703 | 348 | 4.61 / 1125.24 | 5 | 48 |
7 | 8 | 0.00 | 450 | 14.26 | 276 | 1771 | 6.38 / 1127.01 | 6 | 53 |
Average= | 6.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.20 | 60 | 14.26 | 350 | 299 | 0.30 / 1114.29 | 6 | 7 |
2 | 3 | 1033.20 | 2 | 13.19 | 1158 | 31 | 0.33 / 1114.32 | 5 | 9 |
3 | 7 | 2003.48 | 105 | 10.24 | 1777 | 1911 | 2.24 / 1116.23 | 9 | 20 |
4 | 13 | 1914.72 | 36 | 12.89 | 1771 | 822 | 3.06 / 1117.05 | 5 | 36 |
5 | 13 | 1498.64 | 36 | 13.21 | 1478 | 703 | 3.77 / 1117.75 | 5 | 39 |
6 | 13 | 1175.20 | 36 | 13.37 | 1245 | 599 | 4.36 / 1118.35 | 5 | 44 |
7 | 13 | 521.48 | 36 | 13.72 | 739 | 365 | 4.73 / 1118.72 | 5 | 48 |
8 | 13 | 36.56 | 36 | 14.26 | 312 | 160 | 4.89 / 1118.88 | 6 | 38 |
9 | 8 | -0.08 | 450 | 14.27 | 273 | 1753 | 6.64 / 1120.63 | 6 | 64 |
Average= | 6.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.84 | 60 | 14.28 | 346 | 296 | 0.30 / 1107.76 | 6 | 7 |
2 | 7 | 2014.24 | 106 | 10.19 | 1799 | 1943 | 2.24 / 1109.70 | 5 | 17 |
3 | 13 | 1922.28 | 36 | 12.88 | 1780 | 825 | 3.06 / 1110.53 | 5 | 33 |
4 | 13 | 1612.64 | 36 | 13.13 | 1565 | 740 | 3.80 / 1111.27 | 5 | 39 |
5 | 13 | 1073.44 | 36 | 13.40 | 1174 | 566 | 4.37 / 1111.83 | 5 | 45 |
6 | 13 | 517.32 | 36 | 13.72 | 748 | 369 | 4.74 / 1112.20 | 5 | 49 |
7 | 8 | -0.04 | 450 | 14.26 | 278 | 1784 | 6.52 / 1113.99 | 6 | 59 |
Average= | 6.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.96 | 59 | 14.29 | 343 | 289 | 0.29 / 1101.31 | 6 | 9 |
2 | 7 | 2015.68 | 105 | 10.22 | 1796 | 1927 | 2.22 / 1103.24 | 5 | 16 |
3 | 13 | 1925.84 | 36 | 12.91 | 1776 | 825 | 3.04 / 1104.07 | 5 | 32 |
4 | 13 | 1510.12 | 36 | 13.20 | 1485 | 706 | 3.75 / 1104.77 | 5 | 38 |
5 | 13 | 1067.24 | 36 | 13.41 | 1168 | 564 | 4.31 / 1105.34 | 5 | 43 |
6 | 13 | 522.08 | 36 | 13.73 | 747 | 369 | 4.68 / 1105.71 | 5 | 49 |
7 | 8 | 0.00 | 450 | 14.29 | 273 | 1756 | 6.44 / 1107.46 | 6 | 53 |
Average= | 6.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.72 | 62 | 14.28 | 339 | 300 | 0.30 / 1094.79 | 6 | 7 |
2 | 3 | 965.20 | -1 | 14.28 | 339 | 0 | 0.00 / 1094.79 | 6 | 7 |
3 | 7 | 2009.60 | 106 | 10.29 | 1789 | 1951 | 2.25 / 1096.74 | 7 | 16 |
4 | 13 | 1917.80 | 36 | 12.89 | 1771 | 822 | 3.07 / 1097.56 | 5 | 33 |
5 | 13 | 1598.56 | 36 | 13.14 | 1542 | 729 | 3.80 / 1098.29 | 5 | 38 |
6 | 13 | 955.56 | 36 | 13.47 | 1075 | 521 | 4.32 / 1098.82 | 5 | 45 |
7 | 13 | 426.60 | 36 | 13.81 | 657 | 327 | 4.65 / 1099.14 | 5 | 47 |
8 | 13 | 25.36 | 36 | 14.29 | 297 | 153 | 4.80 / 1099.30 | 6 | 33 |
9 | 8 | 0.00 | 450 | 14.29 | 269 | 1730 | 6.53 / 1101.02 | 6 | 62 |
Average= | 6.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.60 | 62 | 14.29 | 345 | 306 | 0.31 / 1088.41 | 6 | 8 |
2 | 7 | 2014.64 | 106 | 10.19 | 1794 | 1938 | 2.24 / 1090.35 | 8 | 16 |
3 | 13 | 1933.04 | 36 | 12.89 | 1777 | 825 | 3.07 / 1091.18 | 5 | 33 |
4 | 13 | 1530.64 | 36 | 13.18 | 1501 | 712 | 3.78 / 1091.89 | 5 | 38 |
5 | 13 | 896.36 | 36 | 13.49 | 1032 | 501 | 4.28 / 1092.39 | 5 | 45 |
6 | 13 | 480.64 | 36 | 13.75 | 705 | 349 | 4.63 / 1092.74 | 5 | 49 |
7 | 8 | -0.16 | 450 | 14.27 | 273 | 1753 | 6.38 / 1094.49 | 6 | 55 |
Average= | 6.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.76 | 62 | 14.29 | 341 | 302 | 0.30 / 1081.75 | 6 | 7 |
2 | 7 | 2004.68 | 105 | 10.22 | 1789 | 1920 | 2.22 / 1083.67 | 7 | 16 |
3 | 13 | 1919.96 | 36 | 12.88 | 1779 | 825 | 3.05 / 1084.49 | 5 | 32 |
4 | 13 | 1606.88 | 36 | 13.13 | 1552 | 734 | 3.78 / 1085.23 | 5 | 37 |
5 | 13 | 1156.52 | 36 | 13.36 | 1231 | 592 | 4.37 / 1085.82 | 5 | 43 |
6 | 13 | 502.68 | 36 | 13.73 | 731 | 361 | 4.73 / 1086.18 | 5 | 48 |
7 | 13 | 37.24 | 36 | 14.27 | 318 | 163 | 4.90 / 1086.34 | 6 | 35 |
8 | 8 | -0.16 | 450 | 14.27 | 275 | 1766 | 6.66 / 1088.11 | 6 | 58 |
Average= | 6.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.44 | 62 | 14.28 | 342 | 303 | 0.30 / 1075.23 | 6 | 8 |
2 | 7 | 2008.24 | 105 | 10.18 | 1795 | 1919 | 2.22 / 1077.15 | 8 | 16 |
3 | 13 | 1933.80 | 36 | 12.88 | 1787 | 829 | 3.05 / 1077.98 | 5 | 31 |
4 | 13 | 1639.92 | 36 | 13.11 | 1583 | 747 | 3.80 / 1078.73 | 5 | 37 |
5 | 13 | 1014.68 | 36 | 13.42 | 1136 | 549 | 4.35 / 1079.27 | 5 | 45 |
6 | 13 | 576.36 | 36 | 13.66 | 799 | 393 | 4.74 / 1079.67 | 5 | 49 |
7 | 8 | -0.12 | 450 | 14.26 | 277 | 1778 | 6.52 / 1081.45 | 6 | 58 |
Average= | 6.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.76 | 62 | 14.25 | 339 | 300 | 0.30 / 1068.47 | 6 | 6 |
2 | 7 | 2014.12 | 105 | 10.14 | 1797 | 1913 | 2.21 / 1070.38 | 6 | 19 |
3 | 13 | 1926.80 | 36 | 12.87 | 1774 | 822 | 3.03 / 1071.20 | 5 | 35 |
4 | 13 | 1719.28 | 36 | 13.06 | 1634 | 768 | 3.80 / 1071.97 | 5 | 38 |
5 | 13 | 1366.40 | 36 | 13.25 | 1377 | 657 | 4.46 / 1072.63 | 5 | 41 |
6 | 13 | 567.84 | 36 | 13.69 | 776 | 382 | 4.84 / 1073.01 | 5 | 47 |
7 | 13 | 55.44 | 36 | 14.25 | 329 | 169 | 5.01 / 1073.18 | 6 | 37 |
8 | 8 | -0.16 | 450 | 14.26 | 273 | 1752 | 6.76 / 1074.93 | 6 | 61 |
Average= | 6.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.96 | 61 | 14.24 | 344 | 299 | 0.30 / 1062.31 | 6 | 6 |
2 | 3 | 1023.88 | 1 | 12.97 | 1133 | 15 | 0.31 / 1062.33 | 5 | 6 |
3 | 7 | 1574.80 | 105 | 10.59 | 1483 | 1649 | 1.96 / 1063.98 | 6 | 25 |
4 | 13 | 1510.12 | 36 | 13.03 | 1481 | 695 | 2.66 / 1064.67 | 5 | 39 |
5 | 13 | 1414.52 | 36 | 13.14 | 1408 | 666 | 3.32 / 1065.34 | 5 | 40 |
6 | 13 | 978.76 | 36 | 13.40 | 1098 | 530 | 3.85 / 1065.87 | 5 | 46 |
7 | 13 | 528.08 | 36 | 13.69 | 744 | 367 | 4.22 / 1066.23 | 5 | 48 |
8 | 13 | 37.28 | 36 | 14.23 | 316 | 162 | 4.38 / 1066.40 | 6 | 41 |
9 | 8 | -0.24 | 450 | 14.20 | 277 | 1770 | 6.15 / 1068.17 | 6 | 50 |
Average= | 6.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.88 | 59 | 14.23 | 345 | 290 | 0.29 / 1056.89 | 6 | 6 |
2 | 3 | 1043.52 | 2 | 13.07 | 1172 | 31 | 0.32 / 1056.92 | 5 | 13 |
3 | 7 | 1291.72 | 105 | 10.89 | 1282 | 1466 | 1.79 / 1058.38 | 13 | 29 |
4 | 13 | 1266.92 | 36 | 13.12 | 1308 | 618 | 2.40 / 1059.00 | 5 | 42 |
5 | 13 | 1184.32 | 36 | 13.22 | 1254 | 597 | 3.00 / 1059.60 | 5 | 43 |
6 | 13 | 785.20 | 36 | 13.49 | 959 | 466 | 3.47 / 1060.06 | 5 | 48 |
7 | 13 | 139.76 | 36 | 14.09 | 410 | 208 | 3.67 / 1060.27 | 6 | 39 |
8 | 8 | -0.12 | 450 | 14.23 | 272 | 1742 | 5.42 / 1062.01 | 6 | 48 |
Average= | 6.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.20 | 62 | 14.25 | 345 | 305 | 0.30 / 1051.81 | 6 | 6 |
2 | 3 | 923.92 | -1 | 14.25 | 345 | 0 | 0.00 / 1051.81 | 6 | 6 |
3 | 7 | 1044.96 | 106 | 11.15 | 1100 | 1300 | 1.60 / 1053.11 | 6 | 33 |
4 | 13 | 1047.00 | 36 | 13.22 | 1154 | 549 | 2.15 / 1053.66 | 5 | 44 |
5 | 13 | 981.12 | 36 | 13.32 | 1104 | 529 | 2.68 / 1054.19 | 5 | 44 |
6 | 13 | 783.08 | 36 | 13.46 | 955 | 463 | 3.15 / 1054.65 | 5 | 48 |
7 | 13 | 73.12 | 36 | 14.16 | 356 | 181 | 3.33 / 1054.83 | 6 | 38 |
8 | 8 | -0.28 | 450 | 14.19 | 277 | 1769 | 5.10 / 1056.60 | 6 | 54 |
Average= | 6.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.76 | 62 | 14.22 | 349 | 308 | 0.31 / 1046.72 | 6 | 6 |
2 | 7 | 971.40 | 105 | 11.28 | 1049 | 1242 | 1.55 / 1047.96 | 6 | 31 |
3 | 13 | 972.64 | 36 | 13.27 | 1086 | 519 | 2.07 / 1048.48 | 5 | 44 |
4 | 13 | 906.96 | 36 | 13.37 | 1039 | 500 | 2.57 / 1048.98 | 5 | 44 |
5 | 13 | 708.60 | 36 | 13.52 | 892 | 434 | 3.00 / 1049.42 | 5 | 47 |
6 | 13 | 75.96 | 36 | 14.19 | 349 | 178 | 3.18 / 1049.59 | 6 | 36 |
7 | 13 | 2.92 | 36 | 14.29 | 286 | 147 | 3.33 / 1049.74 | 6 | 33 |
8 | 8 | -0.20 | 450 | 14.23 | 275 | 1761 | 5.09 / 1051.50 | 6 | 62 |
Average= | 6.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.00 | 62 | 14.22 | 348 | 307 | 0.31 / 1041.72 | 6 | 7 |
2 | 7 | 1029.60 | 105 | 11.21 | 1089 | 1282 | 1.59 / 1043.00 | 7 | 31 |
3 | 13 | 1029.64 | 36 | 13.24 | 1128 | 538 | 2.13 / 1043.54 | 5 | 44 |
4 | 13 | 954.48 | 36 | 13.34 | 1071 | 514 | 2.64 / 1044.05 | 5 | 45 |
5 | 13 | 661.48 | 36 | 13.56 | 851 | 415 | 3.06 / 1044.47 | 5 | 48 |
6 | 13 | 114.36 | 36 | 14.10 | 386 | 196 | 3.25 / 1044.66 | 6 | 43 |
7 | 8 | -0.24 | 450 | 14.20 | 274 | 1751 | 5.00 / 1046.41 | 6 | 58 |
Average= | 6.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.12 | 62 | 14.27 | 347 | 307 | 0.31 / 1036.44 | 6 | 6 |
2 | 3 | 1010.24 | 1 | 12.81 | 1132 | 15 | 0.32 / 1036.45 | 5 | 5 |
3 | 7 | 1071.08 | 105 | 11.24 | 1114 | 1315 | 1.64 / 1037.77 | 5 | 31 |
4 | 13 | 1065.88 | 36 | 13.24 | 1155 | 551 | 2.19 / 1038.32 | 5 | 44 |
5 | 13 | 976.84 | 36 | 13.34 | 1088 | 523 | 2.71 / 1038.84 | 5 | 43 |
6 | 13 | 652.96 | 36 | 13.57 | 847 | 414 | 3.12 / 1039.25 | 5 | 49 |
7 | 13 | 116.16 | 36 | 14.08 | 392 | 199 | 3.32 / 1039.45 | 5 | 43 |
8 | 13 | 24.20 | 36 | 14.19 | 319 | 163 | 3.48 / 1039.61 | 6 | 43 |
9 | 8 | -0.44 | 450 | 14.14 | 282 | 1794 | 5.28 / 1041.41 | 6 | 69 |
Average= | 6.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.08 | 62 | 14.22 | 342 | 302 | 0.30 / 1030.82 | 6 | 7 |
2 | 7 | 1417.24 | 105 | 10.72 | 1373 | 1545 | 1.85 / 1032.36 | 7 | 27 |
3 | 13 | 1367.00 | 36 | 13.09 | 1375 | 648 | 2.49 / 1033.01 | 5 | 41 |
4 | 13 | 1280.20 | 36 | 13.19 | 1310 | 622 | 3.12 / 1033.63 | 5 | 42 |
5 | 13 | 966.92 | 36 | 13.40 | 1082 | 522 | 3.64 / 1034.16 | 5 | 46 |
6 | 13 | 202.12 | 36 | 14.02 | 457 | 231 | 3.87 / 1034.39 | 5 | 44 |
7 | 8 | 0.00 | 450 | 14.24 | 272 | 1743 | 5.61 / 1036.13 | 6 | 54 |
Average= | 6.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.96 | 62 | 14.24 | 342 | 302 | 0.30 / 1025.75 | 6 | 7 |
2 | 7 | 1057.88 | 105 | 11.19 | 1114 | 1309 | 1.61 / 1027.06 | 7 | 31 |
3 | 13 | 1055.68 | 36 | 13.23 | 1151 | 548 | 2.16 / 1027.61 | 5 | 44 |
4 | 13 | 978.28 | 36 | 13.34 | 1092 | 524 | 2.68 / 1028.13 | 5 | 45 |
5 | 13 | 676.32 | 36 | 13.55 | 866 | 422 | 3.11 / 1028.56 | 5 | 49 |
6 | 13 | 61.80 | 36 | 14.15 | 347 | 177 | 3.28 / 1028.73 | 6 | 42 |
7 | 8 | -0.20 | 450 | 14.16 | 280 | 1784 | 5.07 / 1030.52 | 6 | 56 |
Average= | 6.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.76 | 61 | 14.28 | 339 | 295 | 0.30 / 1020.47 | 6 | 7 |
2 | 3 | 1024.00 | 1 | 13.04 | 1125 | 15 | 0.31 / 1020.48 | 5 | 7 |
3 | 7 | 1198.72 | 105 | 11.08 | 1223 | 1423 | 1.73 / 1021.91 | 7 | 30 |
4 | 13 | 1161.96 | 36 | 13.18 | 1231 | 584 | 2.32 / 1022.49 | 5 | 45 |
5 | 13 | 1078.56 | 36 | 13.28 | 1170 | 559 | 2.88 / 1023.05 | 5 | 45 |
6 | 13 | 775.16 | 36 | 13.49 | 945 | 459 | 3.34 / 1023.51 | 5 | 48 |
7 | 13 | 113.08 | 36 | 14.13 | 386 | 196 | 3.53 / 1023.71 | 6 | 42 |
8 | 8 | -0.24 | 450 | 14.21 | 273 | 1746 | 5.28 / 1025.45 | 6 | 58 |
Average= | 6.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.92 | 59 | 14.21 | 355 | 298 | 0.30 / 1014.66 | 6 | 9 |
2 | 3 | 1031.88 | 2 | 13.03 | 1152 | 30 | 0.33 / 1014.69 | 5 | 10 |
3 | 7 | 1574.32 | 105 | 10.69 | 1472 | 1652 | 1.98 / 1016.35 | 10 | 26 |
4 | 13 | 1505.16 | 36 | 13.03 | 1475 | 692 | 2.67 / 1017.04 | 5 | 37 |
5 | 13 | 1411.48 | 36 | 13.14 | 1403 | 664 | 3.34 / 1017.70 | 5 | 40 |
6 | 13 | 879.36 | 36 | 13.46 | 1019 | 494 | 3.83 / 1018.20 | 5 | 45 |
7 | 13 | 241.72 | 36 | 14.00 | 491 | 247 | 4.08 / 1018.44 | 5 | 42 |
8 | 8 | -0.28 | 450 | 14.24 | 270 | 1730 | 5.81 / 1020.17 | 6 | 56 |
Average= | 6.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.12 | 62 | 14.25 | 351 | 310 | 0.31 / 1009.56 | 6 | 7 |
2 | 3 | 952.40 | -1 | 14.25 | 351 | 0 | 0.00 / 1009.56 | 6 | 7 |
3 | 7 | 1033.80 | 106 | 11.27 | 1094 | 1307 | 1.62 / 1010.87 | 7 | 34 |
4 | 13 | 1017.36 | 36 | 13.25 | 1121 | 535 | 2.15 / 1011.40 | 5 | 45 |
5 | 13 | 946.40 | 36 | 13.36 | 1071 | 515 | 2.67 / 1011.92 | 5 | 45 |
6 | 13 | 849.04 | 36 | 13.44 | 996 | 482 | 3.15 / 1012.40 | 5 | 47 |
7 | 13 | 78.80 | 36 | 14.17 | 352 | 180 | 3.33 / 1012.58 | 6 | 39 |
8 | 8 | -0.04 | 450 | 14.18 | 280 | 1787 | 5.11 / 1014.37 | 6 | 55 |
Average= | 6.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.92 | 62 | 14.26 | 349 | 309 | 0.31 / 1004.53 | 6 | 7 |
2 | 7 | 1003.64 | 105 | 11.29 | 1074 | 1273 | 1.58 / 1005.81 | 7 | 34 |
3 | 13 | 1003.52 | 36 | 13.24 | 1109 | 529 | 2.11 / 1006.33 | 5 | 45 |
4 | 13 | 930.96 | 36 | 13.36 | 1057 | 508 | 2.62 / 1006.84 | 5 | 46 |
5 | 13 | 736.36 | 36 | 13.51 | 909 | 442 | 3.06 / 1007.28 | 5 | 49 |
6 | 13 | 43.72 | 36 | 14.21 | 325 | 166 | 3.23 / 1007.45 | 6 | 40 |
7 | 8 | -0.20 | 450 | 14.19 | 282 | 1801 | 5.03 / 1009.25 | 6 | 51 |
Average= | 6.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.96 | 62 | 14.29 | 341 | 302 | 0.30 / 999.27 | 6 | 8 |
2 | 7 | 1142.04 | 105 | 11.15 | 1180 | 1381 | 1.68 / 1000.65 | 8 | 31 |
3 | 13 | 1116.92 | 36 | 13.20 | 1192 | 566 | 2.25 / 1001.22 | 5 | 41 |
4 | 13 | 1044.68 | 36 | 13.31 | 1143 | 548 | 2.80 / 1001.77 | 5 | 44 |
5 | 13 | 948.12 | 36 | 13.39 | 1069 | 515 | 3.31 / 1002.28 | 5 | 47 |
6 | 13 | 75.44 | 36 | 14.18 | 351 | 179 | 3.49 / 1002.46 | 6 | 41 |
7 | 8 | -0.28 | 450 | 14.20 | 276 | 1764 | 5.26 / 1004.22 | 6 | 54 |
Average= | 6.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.20 | 62 | 14.31 | 346 | 307 | 0.31 / 993.18 | 6 | 7 |
2 | 7 | 1634.88 | 105 | 10.68 | 1518 | 1702 | 2.01 / 994.88 | 5 | 25 |
3 | 13 | 1565.84 | 36 | 13.04 | 1516 | 712 | 2.72 / 995.59 | 5 | 39 |
4 | 13 | 1472.76 | 36 | 13.15 | 1451 | 687 | 3.41 / 996.28 | 5 | 39 |
5 | 13 | 932.80 | 36 | 13.46 | 1065 | 516 | 3.92 / 996.79 | 5 | 47 |
6 | 13 | 289.96 | 36 | 13.97 | 538 | 271 | 4.19 / 997.06 | 5 | 42 |
7 | 13 | 17.16 | 36 | 14.31 | 296 | 152 | 4.35 / 997.22 | 6 | 36 |
8 | 8 | -0.12 | 450 | 14.26 | 273 | 1752 | 6.10 / 998.97 | 6 | 65 |
Average= | 6.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.68 | 62 | 14.32 | 339 | 301 | 0.30 / 986.82 | 6 | 7 |
2 | 7 | 2014.24 | 105 | 10.38 | 1785 | 1945 | 2.25 / 988.77 | 5 | 20 |
3 | 13 | 1921.88 | 36 | 12.88 | 1771 | 821 | 3.07 / 989.59 | 5 | 35 |
4 | 13 | 1417.72 | 36 | 13.24 | 1412 | 673 | 3.74 / 990.26 | 5 | 41 |
5 | 13 | 1014.72 | 36 | 13.44 | 1123 | 543 | 4.28 / 990.80 | 5 | 45 |
6 | 13 | 381.76 | 36 | 13.89 | 613 | 307 | 4.59 / 991.11 | 5 | 45 |
7 | 8 | -0.04 | 450 | 14.27 | 274 | 1759 | 6.35 / 992.87 | 6 | 54 |
Average= | 6.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.76 | 62 | 14.29 | 349 | 309 | 0.31 / 980.28 | 6 | 9 |
2 | 7 | 2005.08 | 106 | 10.39 | 1779 | 1959 | 2.27 / 982.24 | 5 | 21 |
3 | 13 | 1918.72 | 36 | 12.90 | 1764 | 819 | 3.09 / 983.06 | 5 | 35 |
4 | 13 | 1508.92 | 36 | 13.19 | 1477 | 701 | 3.79 / 983.76 | 5 | 39 |
5 | 13 | 1078.64 | 36 | 13.41 | 1169 | 564 | 4.35 / 984.33 | 5 | 45 |
6 | 13 | 439.60 | 36 | 13.86 | 657 | 328 | 4.68 / 984.66 | 5 | 45 |
7 | 13 | 6.48 | 36 | 14.35 | 283 | 146 | 4.83 / 984.80 | 6 | 33 |
8 | 8 | -0.28 | 450 | 14.29 | 267 | 1717 | 6.54 / 986.52 | 6 | 63 |
Average= | 6.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.52 | 62 | 14.25 | 353 | 312 | 0.31 / 973.86 | 6 | 9 |
2 | 7 | 2005.04 | 105 | 10.41 | 1779 | 1945 | 2.26 / 975.81 | 9 | 22 |
3 | 13 | 1917.68 | 36 | 12.87 | 1768 | 819 | 3.08 / 976.63 | 5 | 36 |
4 | 13 | 1508.12 | 36 | 13.19 | 1481 | 703 | 3.78 / 977.33 | 5 | 39 |
5 | 13 | 1075.52 | 36 | 13.41 | 1166 | 563 | 4.34 / 977.89 | 5 | 45 |
6 | 13 | 425.08 | 36 | 13.86 | 648 | 323 | 4.67 / 978.22 | 5 | 47 |
7 | 8 | 0.00 | 450 | 14.26 | 274 | 1758 | 6.42 / 979.98 | 6 | 56 |
Average= | 6.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.48 | 62 | 14.23 | 351 | 310 | 0.31 / 967.38 | 6 | 8 |
2 | 7 | 2010.56 | 106 | 10.42 | 1787 | 1974 | 2.28 / 969.35 | 8 | 22 |
3 | 13 | 1927.44 | 36 | 12.88 | 1773 | 822 | 3.11 / 970.18 | 5 | 36 |
4 | 13 | 1503.80 | 36 | 13.19 | 1478 | 702 | 3.81 / 970.88 | 5 | 39 |
5 | 13 | 1067.40 | 36 | 13.41 | 1164 | 562 | 4.37 / 971.44 | 5 | 45 |
6 | 13 | 414.76 | 36 | 13.86 | 640 | 319 | 4.69 / 971.76 | 5 | 47 |
7 | 8 | 0.08 | 450 | 14.23 | 280 | 1793 | 6.48 / 973.55 | 6 | 58 |
Average= | 6.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.16 | 62 | 14.26 | 347 | 307 | 0.31 / 960.94 | 6 | 9 |
2 | 7 | 2005.12 | 106 | 10.45 | 1785 | 1977 | 2.28 / 962.91 | 9 | 22 |
3 | 13 | 1917.16 | 36 | 12.88 | 1770 | 821 | 3.10 / 963.73 | 5 | 36 |
4 | 13 | 1503.32 | 36 | 13.19 | 1475 | 700 | 3.81 / 964.44 | 5 | 39 |
5 | 13 | 977.48 | 36 | 13.45 | 1093 | 529 | 4.33 / 964.96 | 5 | 47 |
6 | 13 | 444.72 | 36 | 13.83 | 664 | 331 | 4.66 / 965.30 | 5 | 47 |
7 | 8 | -0.04 | 450 | 14.24 | 277 | 1775 | 6.44 / 967.07 | 6 | 56 |
Average= | 6.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.12 | 62 | 14.22 | 360 | 317 | 0.32 / 954.50 | 6 | 9 |
2 | 7 | 2004.08 | 105 | 10.48 | 1781 | 1960 | 2.28 / 956.46 | 5 | 23 |
3 | 13 | 1914.44 | 36 | 12.88 | 1764 | 818 | 3.10 / 957.28 | 5 | 36 |
4 | 13 | 1504.00 | 36 | 13.19 | 1475 | 700 | 3.80 / 957.98 | 5 | 39 |
5 | 13 | 984.60 | 36 | 13.45 | 1093 | 529 | 4.32 / 958.51 | 5 | 47 |
6 | 13 | 452.48 | 36 | 13.83 | 669 | 333 | 4.66 / 958.84 | 5 | 47 |
7 | 8 | -0.08 | 450 | 14.22 | 280 | 1792 | 6.45 / 960.63 | 6 | 60 |
Average= | 6.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.24 | 62 | 14.23 | 356 | 314 | 0.31 / 948.04 | 6 | 8 |
2 | 7 | 2003.32 | 106 | 10.46 | 1783 | 1977 | 2.29 / 950.02 | 8 | 22 |
3 | 13 | 1909.04 | 36 | 12.86 | 1760 | 815 | 3.11 / 950.84 | 5 | 37 |
4 | 13 | 1494.36 | 36 | 13.18 | 1468 | 697 | 3.80 / 951.53 | 5 | 39 |
5 | 13 | 964.84 | 36 | 13.45 | 1081 | 523 | 4.33 / 952.06 | 5 | 48 |
6 | 13 | 425.16 | 36 | 13.84 | 649 | 323 | 4.65 / 952.38 | 5 | 48 |
7 | 8 | -0.16 | 450 | 14.20 | 282 | 1802 | 6.45 / 954.18 | 6 | 48 |
Average= | 6.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.16 | 62 | 14.23 | 354 | 312 | 0.31 / 941.42 | 6 | 10 |
2 | 7 | 2011.00 | 105 | 10.49 | 1788 | 1969 | 2.28 / 943.39 | 10 | 23 |
3 | 13 | 1914.40 | 36 | 12.87 | 1766 | 818 | 3.10 / 944.21 | 5 | 36 |
4 | 13 | 1499.04 | 36 | 13.19 | 1459 | 693 | 3.79 / 944.90 | 5 | 39 |
5 | 13 | 1074.76 | 36 | 13.40 | 1162 | 561 | 4.35 / 945.47 | 5 | 46 |
6 | 13 | 422.92 | 36 | 13.84 | 650 | 324 | 4.68 / 945.79 | 5 | 48 |
7 | 13 | 19.00 | 36 | 14.30 | 301 | 155 | 4.83 / 945.94 | 6 | 39 |
8 | 8 | -0.20 | 450 | 14.22 | 279 | 1785 | 6.62 / 947.73 | 6 | 60 |
Average= | 6.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.40 | 62 | 14.25 | 354 | 313 | 0.31 / 934.96 | 6 | 10 |
2 | 7 | 2006.48 | 105 | 10.50 | 1781 | 1964 | 2.28 / 936.92 | 10 | 23 |
3 | 13 | 1917.08 | 36 | 12.86 | 1766 | 818 | 3.09 / 937.74 | 5 | 36 |
4 | 13 | 1504.32 | 36 | 13.18 | 1469 | 697 | 3.79 / 938.44 | 5 | 40 |
5 | 13 | 1066.40 | 36 | 13.40 | 1159 | 559 | 4.35 / 939.00 | 5 | 47 |
6 | 13 | 413.28 | 36 | 13.85 | 640 | 319 | 4.67 / 939.32 | 5 | 47 |
7 | 8 | -0.08 | 450 | 14.20 | 281 | 1796 | 6.46 / 941.11 | 6 | 58 |
Average= | 6.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.00 | 62 | 14.25 | 349 | 308 | 0.31 / 928.45 | 6 | 11 |
2 | 7 | 2012.76 | 105 | 10.48 | 1789 | 1969 | 2.28 / 930.42 | 11 | 23 |
3 | 13 | 1915.64 | 36 | 12.85 | 1764 | 816 | 3.09 / 931.24 | 5 | 37 |
4 | 13 | 1709.96 | 36 | 13.07 | 1620 | 762 | 3.86 / 932.00 | 5 | 38 |
5 | 13 | 1045.56 | 36 | 13.40 | 1144 | 552 | 4.41 / 932.55 | 5 | 46 |
6 | 13 | 395.24 | 36 | 13.89 | 622 | 311 | 4.72 / 932.86 | 5 | 46 |
7 | 8 | -0.12 | 450 | 14.22 | 279 | 1785 | 6.50 / 934.65 | 6 | 63 |
Average= | 6.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.92 | 62 | 14.24 | 361 | 319 | 0.32 / 922.05 | 6 | 9 |
2 | 7 | 2003.80 | 105 | 10.55 | 1787 | 1980 | 2.30 / 924.03 | 9 | 23 |
3 | 13 | 1913.64 | 36 | 12.85 | 1768 | 818 | 3.12 / 924.85 | 5 | 36 |
4 | 13 | 1493.68 | 36 | 13.18 | 1468 | 697 | 3.81 / 925.55 | 5 | 40 |
5 | 13 | 970.72 | 36 | 13.44 | 1088 | 526 | 4.34 / 926.07 | 5 | 47 |
6 | 13 | 332.52 | 36 | 13.96 | 570 | 286 | 4.63 / 926.36 | 5 | 45 |
7 | 8 | 0.00 | 450 | 14.21 | 279 | 1784 | 6.41 / 928.14 | 6 | 58 |
Average= | 6.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.56 | 62 | 14.26 | 355 | 314 | 0.31 / 915.62 | 6 | 9 |
2 | 7 | 2004.88 | 105 | 10.56 | 1782 | 1976 | 2.29 / 917.60 | 9 | 23 |
3 | 13 | 1920.48 | 36 | 12.84 | 1770 | 818 | 3.11 / 918.42 | 5 | 37 |
4 | 13 | 1506.36 | 36 | 13.17 | 1476 | 700 | 3.81 / 919.12 | 5 | 40 |
5 | 13 | 1085.36 | 36 | 13.39 | 1173 | 565 | 4.37 / 919.68 | 5 | 46 |
6 | 13 | 330.64 | 36 | 13.97 | 564 | 284 | 4.66 / 919.97 | 5 | 43 |
7 | 8 | 0.16 | 450 | 14.23 | 276 | 1767 | 6.42 / 921.73 | 6 | 55 |
Average= | 6.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.44 | 62 | 14.19 | 371 | 326 | 0.33 / 909.16 | 6 | 12 |
2 | 7 | 2015.04 | 105 | 10.61 | 1796 | 2001 | 2.33 / 911.16 | 12 | 24 |
3 | 13 | 1921.32 | 36 | 12.84 | 1772 | 819 | 3.15 / 911.98 | 5 | 36 |
4 | 13 | 1501.80 | 36 | 13.17 | 1472 | 698 | 3.84 / 912.68 | 5 | 39 |
5 | 13 | 973.96 | 36 | 13.45 | 1086 | 526 | 4.37 / 913.21 | 5 | 47 |
6 | 13 | 430.80 | 36 | 13.85 | 652 | 325 | 4.70 / 913.53 | 5 | 47 |
7 | 8 | -0.16 | 450 | 14.21 | 278 | 1778 | 6.47 / 915.31 | 6 | 56 |
Average= | 6.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.52 | 62 | 14.23 | 363 | 320 | 0.32 / 902.71 | 6 | 10 |
2 | 7 | 2007.04 | 105 | 10.67 | 1786 | 2001 | 2.32 / 904.71 | 10 | 24 |
3 | 13 | 1913.92 | 36 | 12.86 | 1763 | 816 | 3.14 / 905.53 | 5 | 37 |
4 | 13 | 1408.00 | 36 | 13.21 | 1412 | 671 | 3.81 / 906.20 | 5 | 40 |
5 | 13 | 991.72 | 36 | 13.43 | 1105 | 534 | 4.34 / 906.73 | 5 | 46 |
6 | 13 | 347.28 | 36 | 13.93 | 587 | 294 | 4.64 / 907.03 | 5 | 46 |
7 | 8 | 0.08 | 450 | 14.18 | 284 | 1812 | 6.45 / 908.84 | 6 | 59 |
Average= | 6.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.00 | 62 | 14.22 | 357 | 315 | 0.31 / 896.24 | 6 | 10 |
2 | 7 | 2012.56 | 106 | 10.70 | 1790 | 2030 | 2.34 / 898.27 | 10 | 25 |
3 | 13 | 1916.60 | 36 | 12.85 | 1760 | 814 | 3.16 / 899.08 | 5 | 36 |
4 | 13 | 1492.00 | 36 | 13.17 | 1460 | 692 | 3.85 / 899.77 | 5 | 40 |
5 | 13 | 960.56 | 36 | 13.45 | 1075 | 521 | 4.37 / 900.29 | 5 | 47 |
6 | 13 | 319.84 | 36 | 13.96 | 555 | 279 | 4.65 / 900.57 | 5 | 44 |
7 | 8 | 0.00 | 450 | 14.20 | 284 | 1815 | 6.47 / 902.39 | 6 | 59 |
Average= | 6.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.08 | 62 | 14.24 | 354 | 313 | 0.31 / 889.68 | 6 | 12 |
2 | 7 | 2011.76 | 106 | 10.74 | 1792 | 2040 | 2.35 / 891.72 | 12 | 24 |
3 | 13 | 1915.76 | 36 | 12.83 | 1768 | 817 | 3.17 / 892.54 | 5 | 36 |
4 | 13 | 1498.56 | 36 | 13.16 | 1474 | 698 | 3.87 / 893.24 | 5 | 40 |
5 | 13 | 974.16 | 36 | 13.44 | 1089 | 527 | 4.39 / 893.77 | 5 | 47 |
6 | 13 | 532.76 | 36 | 13.74 | 744 | 368 | 4.76 / 894.13 | 5 | 48 |
7 | 8 | 0.00 | 450 | 14.19 | 280 | 1788 | 6.55 / 895.92 | 6 | 62 |
Average= | 6.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.00 | 62 | 14.26 | 357 | 316 | 0.32 / 883.31 | 6 | 10 |
2 | 7 | 2004.64 | 105 | 10.80 | 1786 | 2025 | 2.34 / 885.33 | 10 | 25 |
3 | 13 | 1908.00 | 36 | 12.83 | 1753 | 810 | 3.15 / 886.14 | 5 | 37 |
4 | 13 | 1392.00 | 36 | 13.22 | 1391 | 662 | 3.81 / 886.80 | 5 | 41 |
5 | 13 | 972.48 | 36 | 13.44 | 1091 | 528 | 4.34 / 887.33 | 5 | 47 |
6 | 13 | 234.32 | 36 | 14.06 | 486 | 246 | 4.59 / 887.58 | 5 | 40 |
7 | 8 | 0.00 | 450 | 14.20 | 281 | 1796 | 6.38 / 889.37 | 6 | 59 |
Average= | 6.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.04 | 62 | 14.23 | 359 | 317 | 0.32 / 876.87 | 6 | 12 |
2 | 7 | 2003.20 | 105 | 10.84 | 1785 | 2032 | 2.35 / 878.90 | 12 | 25 |
3 | 13 | 1911.88 | 36 | 12.84 | 1761 | 814 | 3.16 / 879.72 | 5 | 36 |
4 | 13 | 1397.76 | 36 | 13.20 | 1401 | 666 | 3.83 / 880.38 | 5 | 41 |
5 | 13 | 1085.08 | 36 | 13.38 | 1173 | 565 | 4.39 / 880.95 | 5 | 45 |
6 | 13 | 220.96 | 36 | 14.07 | 474 | 240 | 4.63 / 881.19 | 5 | 41 |
7 | 8 | -0.20 | 450 | 14.20 | 282 | 1802 | 6.44 / 882.99 | 6 | 60 |
Average= | 6.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.60 | 62 | 14.22 | 358 | 316 | 0.32 / 870.40 | 6 | 10 |
2 | 7 | 2002.84 | 105 | 10.82 | 1787 | 2030 | 2.35 / 872.43 | 10 | 26 |
3 | 13 | 1913.24 | 36 | 12.81 | 1773 | 818 | 3.16 / 873.25 | 5 | 38 |
4 | 13 | 1402.04 | 36 | 13.18 | 1407 | 668 | 3.83 / 873.92 | 5 | 43 |
5 | 13 | 993.40 | 36 | 13.41 | 1107 | 534 | 4.37 / 874.45 | 5 | 48 |
6 | 13 | 355.00 | 36 | 13.91 | 593 | 297 | 4.66 / 874.75 | 5 | 45 |
7 | 8 | 0.00 | 450 | 14.19 | 283 | 1807 | 6.47 / 876.55 | 6 | 61 |
Average= | 6.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.48 | 62 | 14.22 | 368 | 324 | 0.32 / 863.83 | 6 | 11 |
2 | 7 | 2015.16 | 106 | 10.86 | 1799 | 2071 | 2.40 / 865.90 | 11 | 26 |
3 | 13 | 1920.88 | 36 | 12.80 | 1772 | 817 | 3.21 / 866.72 | 5 | 37 |
4 | 13 | 1404.64 | 36 | 13.18 | 1411 | 669 | 3.88 / 867.39 | 5 | 43 |
5 | 13 | 1080.60 | 36 | 13.37 | 1173 | 565 | 4.45 / 867.95 | 5 | 46 |
6 | 13 | 415.48 | 36 | 13.85 | 646 | 322 | 4.77 / 868.27 | 5 | 48 |
7 | 8 | -0.12 | 450 | 14.18 | 284 | 1812 | 6.58 / 870.08 | 6 | 59 |
Average= | 6.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.80 | 62 | 14.24 | 363 | 320 | 0.32 / 857.31 | 6 | 11 |
2 | 7 | 2004.80 | 105 | 10.90 | 1794 | 2053 | 2.37 / 859.36 | 11 | 26 |
3 | 13 | 1916.04 | 36 | 12.79 | 1770 | 815 | 3.19 / 860.17 | 5 | 38 |
4 | 13 | 1394.08 | 36 | 13.17 | 1403 | 665 | 3.85 / 860.84 | 5 | 43 |
5 | 13 | 970.32 | 36 | 13.43 | 1087 | 526 | 4.38 / 861.36 | 5 | 48 |
6 | 13 | 423.24 | 36 | 13.83 | 651 | 324 | 4.70 / 861.69 | 5 | 47 |
7 | 8 | -0.12 | 450 | 14.16 | 285 | 1816 | 6.52 / 863.50 | 6 | 66 |
Average= | 6.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.12 | 62 | 14.25 | 360 | 318 | 0.32 / 850.78 | 6 | 9 |
2 | 7 | 2004.76 | 105 | 10.93 | 1798 | 2063 | 2.38 / 852.84 | 9 | 26 |
3 | 13 | 1912.96 | 36 | 12.80 | 1765 | 813 | 3.19 / 853.66 | 5 | 38 |
4 | 13 | 1481.68 | 36 | 13.13 | 1465 | 692 | 3.89 / 854.35 | 5 | 41 |
5 | 13 | 1048.04 | 36 | 13.36 | 1150 | 553 | 4.44 / 854.90 | 5 | 49 |
6 | 13 | 279.76 | 36 | 13.99 | 526 | 265 | 4.71 / 855.17 | 5 | 44 |
7 | 8 | -0.08 | 450 | 14.17 | 285 | 1817 | 6.52 / 856.98 | 6 | 49 |
Average= | 6.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.48 | 62 | 14.24 | 361 | 319 | 0.32 / 844.23 | 6 | 8 |
2 | 7 | 2012.12 | 105 | 10.96 | 1797 | 2068 | 2.39 / 846.30 | 8 | 26 |
3 | 13 | 1918.68 | 36 | 12.79 | 1769 | 815 | 3.20 / 847.12 | 5 | 37 |
4 | 13 | 1503.08 | 36 | 13.12 | 1475 | 697 | 3.90 / 847.81 | 5 | 41 |
5 | 13 | 1066.44 | 36 | 13.36 | 1164 | 560 | 4.46 / 848.37 | 5 | 49 |
6 | 13 | 300.64 | 36 | 13.97 | 541 | 272 | 4.73 / 848.64 | 5 | 44 |
7 | 8 | -0.04 | 450 | 14.17 | 285 | 1817 | 6.55 / 850.46 | 6 | 61 |
Average= | 6.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.36 | 62 | 14.27 | 352 | 311 | 0.31 / 837.78 | 6 | 11 |
2 | 7 | 2005.96 | 105 | 10.99 | 1798 | 2075 | 2.39 / 839.86 | 11 | 27 |
3 | 13 | 1913.04 | 36 | 12.80 | 1771 | 816 | 3.20 / 840.67 | 5 | 38 |
4 | 13 | 1483.36 | 36 | 13.13 | 1458 | 689 | 3.89 / 841.36 | 5 | 42 |
5 | 13 | 955.08 | 36 | 13.42 | 1079 | 521 | 4.41 / 841.88 | 5 | 49 |
6 | 13 | 203.04 | 36 | 14.09 | 458 | 232 | 4.65 / 842.11 | 6 | 40 |
7 | 8 | -0.04 | 450 | 14.19 | 282 | 1801 | 6.45 / 843.92 | 6 | 55 |
Average= | 6.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.96 | 62 | 14.26 | 358 | 317 | 0.32 / 831.26 | 6 | 10 |
2 | 7 | 2006.60 | 105 | 11.04 | 1806 | 2094 | 2.41 / 833.36 | 10 | 28 |
3 | 13 | 1920.08 | 36 | 12.78 | 1774 | 816 | 3.23 / 834.17 | 5 | 37 |
4 | 13 | 1401.72 | 36 | 13.16 | 1412 | 669 | 3.90 / 834.84 | 5 | 43 |
5 | 13 | 1084.28 | 36 | 13.35 | 1182 | 568 | 4.46 / 835.41 | 5 | 48 |
6 | 13 | 297.64 | 36 | 13.97 | 540 | 272 | 4.73 / 835.68 | 5 | 43 |
7 | 8 | 0.08 | 450 | 14.18 | 280 | 1787 | 6.52 / 837.47 | 6 | 58 |
Average= | 6.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.68 | 62 | 14.26 | 364 | 322 | 0.32 / 824.57 | 6 | 8 |
2 | 7 | 2015.84 | 105 | 11.06 | 1814 | 2107 | 2.43 / 826.67 | 8 | 27 |
3 | 13 | 1922.16 | 36 | 12.77 | 1778 | 817 | 3.25 / 827.49 | 5 | 38 |
4 | 13 | 1497.88 | 36 | 13.10 | 1482 | 699 | 3.94 / 828.19 | 5 | 42 |
5 | 13 | 859.48 | 36 | 13.47 | 1015 | 492 | 4.44 / 828.68 | 5 | 49 |
6 | 13 | 328.16 | 36 | 13.95 | 569 | 286 | 4.72 / 828.97 | 5 | 44 |
7 | 13 | 42.88 | 36 | 14.27 | 327 | 168 | 4.89 / 829.14 | 6 | 40 |
8 | 8 | -0.44 | 450 | 14.17 | 284 | 1811 | 6.70 / 830.95 | 6 | 55 |
Average= | 6.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.84 | 62 | 14.30 | 349 | 309 | 0.31 / 818.07 | 6 | 8 |
2 | 7 | 2003.88 | 105 | 11.10 | 1807 | 2106 | 2.42 / 820.18 | 8 | 27 |
3 | 13 | 1911.20 | 36 | 12.78 | 1767 | 813 | 3.23 / 820.99 | 5 | 38 |
4 | 13 | 1482.16 | 36 | 13.11 | 1467 | 692 | 3.92 / 821.68 | 5 | 41 |
5 | 13 | 952.68 | 36 | 13.42 | 1081 | 522 | 4.44 / 822.21 | 5 | 49 |
6 | 13 | 189.36 | 36 | 14.10 | 451 | 229 | 4.67 / 822.43 | 6 | 42 |
7 | 8 | -0.04 | 450 | 14.18 | 284 | 1812 | 6.48 / 824.25 | 6 | 60 |
Average= | 6.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.28 | 61 | 14.26 | 361 | 314 | 0.31 / 811.28 | 6 | 9 |
2 | 7 | 2006.00 | 105 | 11.18 | 1807 | 2121 | 2.44 / 813.40 | 5 | 29 |
3 | 13 | 1913.40 | 36 | 12.78 | 1767 | 813 | 3.25 / 814.21 | 5 | 38 |
4 | 13 | 1491.84 | 36 | 13.11 | 1474 | 696 | 3.94 / 814.91 | 5 | 42 |
5 | 13 | 857.28 | 36 | 13.47 | 1010 | 490 | 4.43 / 815.40 | 5 | 50 |
6 | 13 | 223.88 | 36 | 14.05 | 481 | 243 | 4.68 / 815.64 | 5 | 40 |
7 | 13 | 22.72 | 36 | 14.29 | 316 | 163 | 4.84 / 815.80 | 6 | 39 |
8 | 13 | 11.00 | 36 | 14.21 | 305 | 156 | 5.00 / 815.96 | 6 | 39 |
9 | 8 | -0.28 | 450 | 14.16 | 283 | 1803 | 6.80 / 817.76 | 6 | 69 |
Average= | 6.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.00 | 61 | 14.29 | 356 | 310 | 0.31 / 804.69 | 6 | 8 |
2 | 7 | 2005.56 | 105 | 11.19 | 1812 | 2129 | 2.44 / 806.82 | 8 | 27 |
3 | 13 | 1916.80 | 36 | 12.77 | 1778 | 817 | 3.26 / 807.64 | 5 | 37 |
4 | 13 | 1495.64 | 36 | 13.10 | 1474 | 695 | 3.95 / 808.33 | 5 | 41 |
5 | 13 | 1063.52 | 36 | 13.34 | 1167 | 560 | 4.51 / 808.89 | 5 | 47 |
6 | 13 | 288.32 | 36 | 13.98 | 535 | 269 | 4.78 / 809.16 | 5 | 43 |
7 | 8 | -0.08 | 450 | 14.18 | 282 | 1799 | 6.58 / 810.96 | 6 | 57 |
Average= | 6.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.48 | 61 | 14.32 | 352 | 307 | 0.31 / 798.19 | 6 | 8 |
2 | 7 | 2004.96 | 105 | 11.21 | 1810 | 2130 | 2.44 / 800.32 | 8 | 28 |
3 | 13 | 1906.96 | 36 | 12.77 | 1772 | 815 | 3.25 / 801.13 | 5 | 38 |
4 | 13 | 1481.88 | 36 | 13.10 | 1474 | 695 | 3.95 / 801.83 | 5 | 42 |
5 | 13 | 948.84 | 36 | 13.41 | 1079 | 521 | 4.47 / 802.35 | 5 | 48 |
6 | 13 | 195.64 | 36 | 14.09 | 455 | 231 | 4.70 / 802.58 | 6 | 40 |
7 | 8 | -0.12 | 450 | 14.19 | 282 | 1801 | 6.50 / 804.38 | 6 | 60 |
Average= | 6.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.68 | 61 | 14.28 | 357 | 311 | 0.31 / 791.70 | 6 | 8 |
2 | 7 | 2003.20 | 106 | 11.25 | 1807 | 2155 | 2.47 / 793.85 | 5 | 28 |
3 | 13 | 1905.24 | 36 | 12.77 | 1768 | 813 | 3.28 / 794.66 | 5 | 37 |
4 | 13 | 1390.32 | 36 | 13.14 | 1398 | 661 | 3.94 / 795.33 | 5 | 43 |
5 | 13 | 967.28 | 36 | 13.40 | 1093 | 527 | 4.47 / 795.85 | 5 | 49 |
6 | 13 | 206.44 | 36 | 14.09 | 464 | 235 | 4.70 / 796.09 | 6 | 41 |
7 | 8 | -0.08 | 450 | 14.19 | 281 | 1794 | 6.50 / 797.88 | 6 | 57 |
Average= | 6.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.20 | 61 | 14.31 | 355 | 310 | 0.31 / 784.90 | 6 | 9 |
2 | 7 | 2006.96 | 106 | 11.33 | 1813 | 2177 | 2.49 / 787.08 | 9 | 29 |
3 | 13 | 1909.20 | 36 | 12.79 | 1774 | 817 | 3.30 / 787.90 | 5 | 35 |
4 | 13 | 1368.32 | 36 | 13.16 | 1393 | 660 | 3.96 / 788.56 | 5 | 43 |
5 | 13 | 937.24 | 36 | 13.41 | 1077 | 520 | 4.48 / 789.08 | 5 | 46 |
6 | 13 | 381.64 | 36 | 13.86 | 623 | 311 | 4.79 / 789.39 | 5 | 46 |
7 | 13 | 26.80 | 36 | 14.26 | 323 | 166 | 4.96 / 789.55 | 6 | 40 |
8 | 8 | -0.24 | 450 | 14.14 | 288 | 1833 | 6.79 / 791.39 | 6 | 60 |
Average= | 6.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.52 | 61 | 14.32 | 353 | 308 | 0.31 / 778.16 | 6 | 8 |
2 | 7 | 2004.12 | 105 | 11.37 | 1814 | 2166 | 2.47 / 780.32 | 5 | 29 |
3 | 13 | 1904.08 | 36 | 12.80 | 1770 | 816 | 3.29 / 781.14 | 5 | 38 |
4 | 13 | 1488.04 | 36 | 13.09 | 1476 | 696 | 3.99 / 781.83 | 5 | 42 |
5 | 13 | 947.92 | 36 | 13.40 | 1089 | 525 | 4.51 / 782.36 | 5 | 49 |
6 | 13 | 198.32 | 36 | 14.07 | 469 | 238 | 4.75 / 782.60 | 5 | 40 |
7 | 13 | 4.40 | 36 | 14.31 | 303 | 156 | 4.90 / 782.75 | 6 | 31 |
8 | 8 | -0.20 | 450 | 14.15 | 289 | 1840 | 6.74 / 784.59 | 6 | 55 |
Average= | 6.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.40 | 60 | 14.31 | 356 | 306 | 0.31 / 771.60 | 6 | 7 |
2 | 3 | 1013.96 | 1 | 12.08 | 1129 | 14 | 0.32 / 771.61 | 5 | 5 |
3 | 7 | 2011.72 | 106 | 11.41 | 1820 | 2201 | 2.52 / 773.82 | 5 | 29 |
4 | 13 | 1815.52 | 36 | 12.89 | 1709 | 793 | 3.31 / 774.61 | 5 | 39 |
5 | 13 | 1308.96 | 36 | 13.19 | 1356 | 644 | 3.96 / 775.25 | 5 | 43 |
6 | 13 | 891.36 | 36 | 13.44 | 1050 | 508 | 4.47 / 775.76 | 5 | 48 |
7 | 13 | 234.56 | 36 | 14.02 | 503 | 254 | 4.72 / 776.01 | 5 | 42 |
8 | 8 | -0.08 | 450 | 14.15 | 288 | 1834 | 6.55 / 777.85 | 6 | 60 |
Average= | 6.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.16 | 60 | 14.31 | 356 | 306 | 0.31 / 765.05 | 6 | 10 |
2 | 7 | 2005.76 | 105 | 11.42 | 1819 | 2181 | 2.49 / 767.23 | 5 | 30 |
3 | 13 | 1912.20 | 36 | 12.81 | 1773 | 818 | 3.30 / 768.05 | 5 | 37 |
4 | 13 | 1386.92 | 36 | 13.14 | 1411 | 667 | 3.97 / 768.72 | 5 | 43 |
5 | 13 | 958.04 | 36 | 13.39 | 1099 | 530 | 4.50 / 769.25 | 5 | 48 |
6 | 13 | 105.56 | 36 | 14.19 | 388 | 198 | 4.70 / 769.45 | 6 | 36 |
7 | 8 | -0.24 | 450 | 14.17 | 290 | 1849 | 6.55 / 771.29 | 6 | 57 |
Average= | 6.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.76 | 60 | 14.25 | 365 | 312 | 0.31 / 758.52 | 6 | 10 |
2 | 7 | 2006.36 | 105 | 11.47 | 1815 | 2186 | 2.50 / 760.71 | 5 | 30 |
3 | 13 | 1915.48 | 36 | 12.82 | 1771 | 817 | 3.32 / 761.52 | 5 | 38 |
4 | 13 | 1397.44 | 36 | 13.15 | 1414 | 669 | 3.98 / 762.19 | 5 | 43 |
5 | 13 | 967.52 | 36 | 13.39 | 1095 | 528 | 4.51 / 762.72 | 5 | 49 |
6 | 13 | 123.04 | 36 | 14.18 | 397 | 203 | 4.72 / 762.92 | 6 | 38 |
7 | 8 | -0.12 | 450 | 14.16 | 286 | 1822 | 6.54 / 764.75 | 6 | 55 |
Average= | 6.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.48 | 60 | 14.22 | 368 | 314 | 0.31 / 751.94 | 6 | 14 |
2 | 7 | 2011.28 | 106 | 11.54 | 1824 | 2231 | 2.55 / 754.17 | 5 | 30 |
3 | 13 | 1915.32 | 36 | 12.82 | 1781 | 822 | 3.37 / 755.00 | 5 | 38 |
4 | 13 | 1478.64 | 36 | 13.12 | 1474 | 696 | 4.06 / 755.69 | 5 | 44 |
5 | 13 | 833.64 | 36 | 13.47 | 996 | 483 | 4.55 / 756.18 | 5 | 49 |
6 | 13 | 55.36 | 36 | 14.23 | 346 | 177 | 4.72 / 756.35 | 6 | 37 |
7 | 8 | -0.08 | 450 | 14.12 | 292 | 1855 | 6.58 / 758.21 | 6 | 63 |
Average= | 6.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.16 | 60 | 14.22 | 366 | 312 | 0.31 / 745.42 | 6 | 13 |
2 | 7 | 2006.24 | 105 | 11.54 | 1818 | 2203 | 2.52 / 747.62 | 13 | 29 |
3 | 13 | 1811.20 | 36 | 12.91 | 1707 | 793 | 3.31 / 748.41 | 5 | 38 |
4 | 13 | 1397.48 | 36 | 13.16 | 1414 | 670 | 3.98 / 749.08 | 5 | 44 |
5 | 13 | 863.36 | 36 | 13.46 | 1013 | 491 | 4.47 / 749.58 | 5 | 48 |
6 | 13 | 112.80 | 36 | 14.16 | 394 | 201 | 4.67 / 749.78 | 6 | 41 |
7 | 8 | 0.08 | 450 | 14.10 | 292 | 1853 | 6.52 / 751.63 | 6 | 61 |
Average= | 6.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.20 | 60 | 14.25 | 365 | 312 | 0.31 / 738.83 | 6 | 14 |
2 | 7 | 2005.44 | 105 | 11.54 | 1818 | 2203 | 2.51 / 741.03 | 14 | 30 |
3 | 13 | 1911.40 | 36 | 12.81 | 1777 | 819 | 3.33 / 741.85 | 5 | 37 |
4 | 13 | 1378.16 | 36 | 13.16 | 1395 | 661 | 4.00 / 742.51 | 5 | 44 |
5 | 13 | 945.40 | 36 | 13.41 | 1081 | 522 | 4.52 / 743.04 | 5 | 47 |
6 | 13 | 92.36 | 36 | 14.19 | 377 | 193 | 4.71 / 743.23 | 6 | 36 |
7 | 8 | -0.12 | 450 | 14.10 | 296 | 1878 | 6.59 / 745.11 | 6 | 59 |
Average= | 6.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.40 | 58 | 14.26 | 377 | 312 | 0.31 / 732.20 | 6 | 11 |
2 | 3 | 1031.20 | 2 | 12.72 | 1153 | 29 | 0.34 / 732.23 | 5 | 9 |
3 | 7 | 2007.28 | 105 | 11.58 | 1818 | 2211 | 2.55 / 734.44 | 9 | 31 |
4 | 13 | 1917.32 | 36 | 12.81 | 1783 | 822 | 3.37 / 735.26 | 5 | 39 |
5 | 13 | 1493.60 | 36 | 13.11 | 1483 | 700 | 4.07 / 735.96 | 5 | 44 |
6 | 13 | 849.84 | 36 | 13.47 | 1013 | 491 | 4.57 / 736.46 | 5 | 49 |
7 | 13 | 100.20 | 36 | 14.19 | 383 | 196 | 4.76 / 736.65 | 6 | 36 |
8 | 8 | 0.08 | 450 | 14.11 | 294 | 1867 | 6.63 / 738.52 | 6 | 63 |
Average= | 6.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.68 | 62 | 14.20 | 371 | 327 | 0.33 / 725.60 | 6 | 14 |
2 | 3 | 965.04 | -1 | 14.20 | 371 | 0 | 0.00 / 725.60 | 6 | 14 |
3 | 7 | 2014.44 | 106 | 11.61 | 1824 | 2245 | 2.57 / 727.85 | 14 | 28 |
4 | 13 | 1813.72 | 36 | 12.91 | 1712 | 796 | 3.37 / 728.64 | 5 | 39 |
5 | 13 | 1399.48 | 36 | 13.15 | 1421 | 673 | 4.04 / 729.32 | 5 | 44 |
6 | 13 | 853.20 | 36 | 13.47 | 1014 | 492 | 4.53 / 729.81 | 5 | 48 |
7 | 13 | 110.80 | 36 | 14.19 | 394 | 201 | 4.73 / 730.01 | 6 | 35 |
8 | 8 | -0.12 | 450 | 14.12 | 296 | 1881 | 6.61 / 731.89 | 6 | 67 |
Average= | 6.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.84 | 62 | 14.21 | 379 | 334 | 0.33 / 718.95 | 6 | 15 |
2 | 7 | 2012.44 | 105 | 11.62 | 1823 | 2224 | 2.56 / 721.17 | 15 | 31 |
3 | 13 | 1817.20 | 36 | 12.90 | 1710 | 794 | 3.35 / 721.97 | 5 | 37 |
4 | 13 | 1404.92 | 36 | 13.16 | 1418 | 672 | 4.02 / 722.64 | 5 | 43 |
5 | 13 | 972.12 | 36 | 13.40 | 1100 | 531 | 4.55 / 723.17 | 5 | 48 |
6 | 13 | 195.48 | 36 | 14.09 | 463 | 235 | 4.79 / 723.41 | 5 | 40 |
7 | 8 | 0.16 | 450 | 14.10 | 295 | 1872 | 6.66 / 725.28 | 6 | 62 |
Average= | 6.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.08 | 62 | 14.19 | 372 | 327 | 0.33 / 712.28 | 6 | 15 |
2 | 7 | 2004.04 | 106 | 11.61 | 1822 | 2242 | 2.57 / 714.52 | 15 | 31 |
3 | 13 | 1907.72 | 36 | 12.82 | 1766 | 815 | 3.38 / 715.34 | 5 | 36 |
4 | 13 | 1477.12 | 36 | 13.12 | 1470 | 694 | 4.08 / 716.03 | 5 | 43 |
5 | 13 | 928.24 | 36 | 13.43 | 1065 | 515 | 4.59 / 716.55 | 5 | 48 |
6 | 13 | 80.48 | 36 | 14.23 | 366 | 187 | 4.78 / 716.74 | 6 | 39 |
7 | 8 | -0.04 | 450 | 14.11 | 296 | 1879 | 6.66 / 718.62 | 6 | 62 |
Average= | 6.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.36 | 62 | 14.18 | 384 | 338 | 0.34 / 705.68 | 6 | 17 |
2 | 7 | 2003.88 | 105 | 11.64 | 1824 | 2229 | 2.57 / 707.91 | 17 | 30 |
3 | 13 | 1811.20 | 36 | 12.91 | 1706 | 793 | 3.36 / 708.70 | 5 | 38 |
4 | 13 | 1495.60 | 36 | 13.11 | 1486 | 701 | 4.06 / 709.40 | 5 | 43 |
5 | 13 | 761.84 | 36 | 13.53 | 938 | 457 | 4.52 / 709.86 | 5 | 49 |
6 | 13 | 120.84 | 36 | 14.18 | 401 | 205 | 4.72 / 710.07 | 6 | 39 |
7 | 8 | -0.16 | 450 | 14.09 | 298 | 1889 | 6.61 / 711.96 | 6 | 67 |
Average= | 6.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.72 | 62 | 14.18 | 385 | 338 | 0.34 / 699.06 | 6 | 17 |
2 | 7 | 2006.08 | 105 | 11.64 | 1829 | 2235 | 2.57 / 701.30 | 17 | 31 |
3 | 13 | 1913.92 | 36 | 12.82 | 1776 | 820 | 3.39 / 702.12 | 5 | 36 |
4 | 13 | 1359.40 | 36 | 13.17 | 1390 | 659 | 4.05 / 702.78 | 5 | 43 |
5 | 13 | 725.24 | 36 | 13.55 | 917 | 447 | 4.50 / 703.22 | 5 | 49 |
6 | 13 | 171.32 | 36 | 14.12 | 443 | 225 | 4.73 / 703.45 | 5 | 40 |
7 | 8 | 0.04 | 450 | 14.08 | 299 | 1894 | 6.62 / 705.34 | 6 | 53 |
Average= | 6.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.92 | 62 | 14.20 | 390 | 343 | 0.34 / 692.10 | 6 | 16 |
2 | 7 | 2005.88 | 105 | 11.64 | 1828 | 2234 | 2.58 / 694.33 | 16 | 30 |
3 | 13 | 1914.92 | 36 | 12.80 | 1787 | 823 | 3.40 / 695.15 | 5 | 35 |
4 | 13 | 1387.84 | 36 | 13.17 | 1411 | 669 | 4.07 / 695.82 | 5 | 43 |
5 | 13 | 962.64 | 36 | 13.42 | 1100 | 531 | 4.60 / 696.36 | 5 | 47 |
6 | 13 | 294.40 | 36 | 13.96 | 556 | 279 | 4.88 / 696.63 | 5 | 46 |
7 | 13 | 12.00 | 36 | 14.26 | 321 | 165 | 5.05 / 696.80 | 6 | 41 |
8 | 8 | 0.20 | 450 | 14.02 | 305 | 1924 | 6.97 / 698.72 | 6 | 70 |
Average= | 6.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.60 | 62 | 14.21 | 386 | 340 | 0.34 / 685.20 | 6 | 15 |
2 | 7 | 2008.64 | 106 | 11.67 | 1836 | 2271 | 2.61 / 687.47 | 15 | 30 |
3 | 13 | 1913.40 | 36 | 12.80 | 1784 | 822 | 3.43 / 688.29 | 5 | 36 |
4 | 13 | 1292.76 | 36 | 13.21 | 1345 | 640 | 4.07 / 688.93 | 5 | 45 |
5 | 13 | 975.00 | 36 | 13.41 | 1111 | 536 | 4.61 / 689.47 | 5 | 47 |
6 | 13 | 99.52 | 36 | 14.20 | 391 | 200 | 4.81 / 689.67 | 6 | 39 |
7 | 13 | 3.16 | 36 | 14.28 | 316 | 162 | 4.97 / 689.83 | 6 | 33 |
8 | 8 | -0.08 | 450 | 14.06 | 304 | 1923 | 6.90 / 691.75 | 6 | 75 |
Average= | 6.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.20 | 62 | 14.19 | 387 | 340 | 0.34 / 678.43 | 6 | 14 |
2 | 7 | 2009.12 | 106 | 11.69 | 1839 | 2279 | 2.62 / 680.71 | 14 | 30 |
3 | 13 | 1911.68 | 36 | 12.82 | 1793 | 828 | 3.45 / 681.54 | 5 | 36 |
4 | 13 | 1369.28 | 36 | 13.18 | 1407 | 668 | 4.11 / 682.21 | 5 | 44 |
5 | 13 | 841.00 | 36 | 13.49 | 1018 | 494 | 4.61 / 682.70 | 5 | 47 |
6 | 13 | 174.40 | 36 | 14.12 | 456 | 232 | 4.84 / 682.93 | 5 | 41 |
7 | 8 | 0.00 | 450 | 14.08 | 304 | 1926 | 6.77 / 684.86 | 6 | 59 |
Average= | 6.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.08 | 62 | 14.21 | 389 | 343 | 0.34 / 671.57 | 6 | 15 |
2 | 7 | 2006.00 | 105 | 11.70 | 1838 | 2258 | 2.60 / 673.83 | 15 | 30 |
3 | 13 | 1911.52 | 36 | 12.81 | 1798 | 829 | 3.43 / 674.66 | 5 | 36 |
4 | 13 | 1487.96 | 36 | 13.11 | 1503 | 709 | 4.14 / 675.37 | 5 | 42 |
5 | 13 | 940.72 | 36 | 13.43 | 1099 | 531 | 4.67 / 675.90 | 5 | 48 |
6 | 13 | 168.92 | 36 | 14.13 | 452 | 230 | 4.90 / 676.13 | 6 | 41 |
7 | 8 | 0.16 | 450 | 14.08 | 310 | 1964 | 6.86 / 678.09 | 6 | 58 |
Average= | 6.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.44 | 62 | 14.22 | 390 | 344 | 0.34 / 664.85 | 6 | 14 |
2 | 7 | 2003.04 | 105 | 11.70 | 1836 | 2256 | 2.60 / 667.10 | 14 | 30 |
3 | 13 | 1907.04 | 36 | 12.82 | 1787 | 825 | 3.42 / 667.93 | 5 | 36 |
4 | 13 | 1286.44 | 36 | 13.22 | 1348 | 642 | 4.07 / 668.57 | 5 | 44 |
5 | 13 | 862.44 | 36 | 13.47 | 1042 | 505 | 4.57 / 669.08 | 5 | 48 |
6 | 13 | 106.52 | 36 | 14.19 | 403 | 206 | 4.78 / 669.28 | 6 | 39 |
7 | 8 | 0.00 | 450 | 14.08 | 307 | 1945 | 6.72 / 671.23 | 6 | 60 |
Average= | 6.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.28 | 62 | 14.26 | 384 | 340 | 0.34 / 657.88 | 6 | 13 |
2 | 7 | 2005.68 | 105 | 11.71 | 1840 | 2262 | 2.60 / 660.14 | 13 | 30 |
3 | 13 | 1907.52 | 36 | 12.82 | 1793 | 828 | 3.43 / 660.97 | 5 | 37 |
4 | 13 | 1374.08 | 36 | 13.18 | 1419 | 673 | 4.10 / 661.64 | 5 | 44 |
5 | 13 | 830.08 | 36 | 13.50 | 1020 | 496 | 4.60 / 662.14 | 5 | 47 |
6 | 13 | 187.16 | 36 | 14.10 | 476 | 242 | 4.84 / 662.38 | 5 | 41 |
7 | 13 | 18.24 | 36 | 14.28 | 332 | 171 | 5.01 / 662.55 | 6 | 41 |
8 | 8 | -0.20 | 450 | 14.03 | 310 | 1957 | 6.97 / 664.51 | 6 | 58 |
Average= | 6.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.24 | 62 | 14.26 | 388 | 343 | 0.34 / 651.10 | 6 | 13 |
2 | 7 | 2013.56 | 105 | 11.73 | 1848 | 2276 | 2.62 / 653.37 | 13 | 30 |
3 | 13 | 1816.92 | 36 | 12.90 | 1735 | 806 | 3.42 / 654.18 | 5 | 37 |
4 | 13 | 1391.32 | 36 | 13.17 | 1437 | 681 | 4.11 / 654.86 | 5 | 43 |
5 | 13 | 957.92 | 36 | 13.41 | 1120 | 541 | 4.65 / 655.40 | 5 | 47 |
6 | 13 | 95.52 | 36 | 14.22 | 394 | 202 | 4.85 / 655.60 | 6 | 38 |
7 | 8 | 0.24 | 450 | 14.11 | 305 | 1937 | 6.79 / 657.54 | 6 | 52 |
Average= | 6.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.44 | 62 | 14.25 | 391 | 345 | 0.35 / 644.24 | 6 | 14 |
2 | 7 | 2005.68 | 105 | 11.71 | 1839 | 2261 | 2.61 / 646.50 | 14 | 31 |
3 | 13 | 1906.40 | 36 | 12.82 | 1793 | 828 | 3.43 / 647.33 | 5 | 36 |
4 | 13 | 1465.56 | 36 | 13.13 | 1490 | 704 | 4.14 / 648.03 | 5 | 43 |
5 | 13 | 912.92 | 36 | 13.45 | 1080 | 523 | 4.66 / 648.55 | 5 | 46 |
6 | 13 | 137.16 | 36 | 14.16 | 434 | 221 | 4.88 / 648.78 | 5 | 40 |
7 | 8 | 0.00 | 450 | 14.08 | 312 | 1977 | 6.86 / 650.75 | 6 | 60 |
Average= | 6.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.28 | 62 | 14.27 | 384 | 340 | 0.34 / 637.52 | 6 | 13 |
2 | 7 | 2003.68 | 105 | 11.78 | 1838 | 2273 | 2.61 / 639.80 | 13 | 31 |
3 | 13 | 1801.12 | 36 | 12.93 | 1710 | 796 | 3.41 / 640.59 | 5 | 37 |
4 | 13 | 1281.12 | 36 | 13.23 | 1348 | 642 | 4.05 / 641.23 | 5 | 45 |
5 | 13 | 853.44 | 36 | 13.49 | 1034 | 502 | 4.55 / 641.74 | 5 | 47 |
6 | 13 | 55.28 | 36 | 14.25 | 364 | 187 | 4.74 / 641.92 | 6 | 40 |
7 | 8 | 0.00 | 450 | 14.08 | 311 | 1970 | 6.71 / 643.89 | 6 | 58 |
Average= | 6.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.20 | 62 | 14.28 | 384 | 340 | 0.34 / 630.69 | 6 | 12 |
2 | 7 | 2004.76 | 106 | 11.75 | 1839 | 2290 | 2.63 / 632.98 | 12 | 31 |
3 | 13 | 1807.00 | 36 | 12.92 | 1724 | 802 | 3.43 / 633.78 | 5 | 38 |
4 | 13 | 1380.64 | 36 | 13.17 | 1429 | 678 | 4.11 / 634.46 | 5 | 44 |
5 | 13 | 845.60 | 36 | 13.49 | 1031 | 501 | 4.61 / 634.96 | 5 | 47 |
6 | 13 | 180.68 | 36 | 14.11 | 471 | 239 | 4.85 / 635.20 | 5 | 43 |
7 | 8 | -0.16 | 450 | 14.06 | 314 | 1987 | 6.84 / 637.18 | 6 | 59 |
Average= | 6.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.44 | 62 | 14.24 | 393 | 347 | 0.35 / 623.87 | 6 | 11 |
2 | 7 | 2005.60 | 105 | 11.77 | 1841 | 2275 | 2.62 / 626.15 | 11 | 31 |
3 | 13 | 1913.52 | 36 | 12.81 | 1802 | 831 | 3.45 / 626.98 | 5 | 36 |
4 | 13 | 1283.36 | 36 | 13.23 | 1358 | 647 | 4.10 / 627.62 | 5 | 45 |
5 | 13 | 962.56 | 36 | 13.42 | 1123 | 543 | 4.64 / 628.17 | 5 | 48 |
6 | 13 | 90.44 | 36 | 14.22 | 395 | 202 | 4.84 / 628.37 | 6 | 41 |
7 | 8 | 0.00 | 450 | 14.08 | 312 | 1977 | 6.82 / 630.35 | 6 | 62 |
Average= | 6.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.04 | 62 | 14.31 | 377 | 334 | 0.33 / 617.04 | 6 | 13 |
2 | 7 | 2008.08 | 106 | 11.78 | 1845 | 2304 | 2.64 / 619.35 | 13 | 31 |
3 | 13 | 1813.16 | 36 | 12.93 | 1730 | 805 | 3.44 / 620.15 | 5 | 38 |
4 | 13 | 1294.84 | 36 | 13.24 | 1365 | 651 | 4.09 / 620.80 | 5 | 45 |
5 | 13 | 779.48 | 36 | 13.55 | 982 | 479 | 4.57 / 621.28 | 5 | 48 |
6 | 13 | 237.32 | 36 | 14.04 | 524 | 265 | 4.84 / 621.55 | 5 | 44 |
7 | 8 | 0.08 | 450 | 14.05 | 313 | 1979 | 6.82 / 623.52 | 6 | 62 |
Average= | 6.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.24 | 62 | 14.31 | 378 | 335 | 0.34 / 609.95 | 6 | 10 |
2 | 7 | 2004.24 | 106 | 11.79 | 1840 | 2300 | 2.63 / 612.24 | 10 | 31 |
3 | 13 | 1804.96 | 36 | 12.92 | 1725 | 802 | 3.44 / 613.05 | 5 | 37 |
4 | 13 | 1383.84 | 36 | 13.19 | 1430 | 679 | 4.12 / 613.73 | 5 | 44 |
5 | 13 | 1053.96 | 36 | 13.39 | 1188 | 573 | 4.69 / 614.30 | 5 | 47 |
6 | 13 | 261.52 | 36 | 14.02 | 540 | 273 | 4.96 / 614.57 | 5 | 44 |
7 | 13 | 29.44 | 36 | 14.28 | 340 | 175 | 5.14 / 614.75 | 6 | 42 |
8 | 8 | -0.24 | 450 | 14.06 | 310 | 1961 | 7.10 / 616.71 | 6 | 63 |
Average= | 6.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.24 | 62 | 14.33 | 376 | 334 | 0.33 / 602.91 | 6 | 10 |
2 | 7 | 2011.24 | 106 | 11.78 | 1847 | 2306 | 2.64 / 605.22 | 10 | 31 |
3 | 13 | 1922.76 | 36 | 12.82 | 1802 | 832 | 3.47 / 606.05 | 5 | 37 |
4 | 13 | 1392.00 | 36 | 13.19 | 1436 | 682 | 4.15 / 606.73 | 5 | 43 |
5 | 13 | 860.88 | 36 | 13.50 | 1042 | 506 | 4.66 / 607.24 | 5 | 48 |
6 | 13 | 211.80 | 36 | 14.10 | 496 | 252 | 4.91 / 607.49 | 5 | 41 |
7 | 13 | 44.60 | 36 | 14.29 | 348 | 179 | 5.09 / 607.67 | 6 | 40 |
8 | 8 | 0.00 | 450 | 14.09 | 306 | 1940 | 7.03 / 609.61 | 6 | 73 |
Average= | 6.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.92 | 61 | 14.34 | 378 | 331 | 0.33 / 596.12 | 6 | 9 |
2 | 3 | 1012.04 | 1 | 12.05 | 1154 | 14 | 0.34 / 596.13 | 5 | 5 |
3 | 7 | 2004.76 | 106 | 11.80 | 1837 | 2298 | 2.64 / 598.43 | 5 | 31 |
4 | 13 | 1803.20 | 36 | 12.91 | 1724 | 801 | 3.44 / 599.23 | 5 | 38 |
5 | 13 | 1353.52 | 36 | 13.20 | 1406 | 668 | 4.11 / 599.90 | 5 | 43 |
6 | 13 | 833.64 | 36 | 13.52 | 1026 | 499 | 4.61 / 600.40 | 5 | 49 |
7 | 13 | 166.08 | 36 | 14.14 | 457 | 233 | 4.84 / 600.63 | 5 | 42 |
8 | 8 | -0.24 | 450 | 14.10 | 307 | 1948 | 6.79 / 602.58 | 6 | 58 |
Average= | 6.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.40 | 61 | 14.35 | 380 | 333 | 0.33 / 589.29 | 6 | 9 |
2 | 7 | 1959.48 | 105 | 11.82 | 1807 | 2243 | 2.58 / 591.54 | 5 | 32 |
3 | 13 | 1858.40 | 36 | 12.82 | 1757 | 811 | 3.39 / 592.35 | 5 | 36 |
4 | 13 | 1422.24 | 36 | 13.16 | 1452 | 688 | 4.07 / 593.04 | 5 | 43 |
5 | 13 | 983.56 | 36 | 13.42 | 1138 | 550 | 4.62 / 593.59 | 5 | 45 |
6 | 13 | 199.40 | 36 | 14.11 | 487 | 247 | 4.87 / 593.83 | 5 | 42 |
7 | 8 | -0.16 | 450 | 14.10 | 308 | 1954 | 6.83 / 595.79 | 6 | 71 |
Average= | 6.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.36 | 60 | 14.36 | 371 | 320 | 0.32 / 582.32 | 6 | 9 |
2 | 3 | 1012.88 | 1 | 12.40 | 1161 | 14 | 0.33 / 582.33 | 5 | 5 |
3 | 7 | 2008.92 | 105 | 11.73 | 1842 | 2269 | 2.60 / 584.60 | 5 | 31 |
4 | 13 | 1911.20 | 36 | 12.79 | 1799 | 828 | 3.43 / 585.43 | 5 | 39 |
5 | 13 | 1379.00 | 36 | 13.19 | 1425 | 677 | 4.11 / 586.11 | 5 | 43 |
6 | 13 | 949.92 | 36 | 13.45 | 1114 | 539 | 4.65 / 586.65 | 5 | 50 |
7 | 13 | 92.12 | 36 | 14.24 | 393 | 201 | 4.85 / 586.85 | 6 | 38 |
8 | 13 | 47.48 | 36 | 14.24 | 354 | 181 | 5.03 / 587.03 | 6 | 41 |
9 | 8 | 0.00 | 450 | 14.12 | 304 | 1932 | 6.96 / 588.96 | 6 | 66 |
Average= | 6.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.20 | 60 | 14.38 | 374 | 323 | 0.32 / 576.19 | 6 | 9 |
2 | 7 | 1484.40 | 105 | 12.10 | 1472 | 1870 | 2.19 / 578.06 | 5 | 36 |
3 | 13 | 1412.28 | 36 | 13.00 | 1444 | 676 | 2.87 / 578.74 | 5 | 43 |
4 | 13 | 1324.24 | 36 | 13.13 | 1382 | 653 | 3.52 / 579.39 | 5 | 44 |
5 | 13 | 770.96 | 36 | 13.54 | 976 | 476 | 4.00 / 579.86 | 5 | 50 |
6 | 13 | 98.52 | 36 | 14.23 | 398 | 204 | 4.20 / 580.07 | 6 | 40 |
7 | 8 | -0.20 | 450 | 14.12 | 304 | 1932 | 6.13 / 582.00 | 6 | 52 |
Average= | 6.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.24 | 60 | 14.38 | 369 | 318 | 0.32 / 569.43 | 6 | 8 |
2 | 7 | 2006.64 | 106 | 11.80 | 1842 | 2304 | 2.62 / 571.74 | 8 | 31 |
3 | 13 | 1805.92 | 36 | 12.90 | 1729 | 803 | 3.43 / 572.54 | 5 | 39 |
4 | 13 | 1361.08 | 36 | 13.19 | 1413 | 671 | 4.10 / 573.21 | 5 | 43 |
5 | 13 | 822.04 | 36 | 13.52 | 1018 | 495 | 4.59 / 573.71 | 5 | 50 |
6 | 13 | 93.72 | 36 | 14.22 | 400 | 205 | 4.80 / 573.91 | 6 | 41 |
7 | 8 | -0.20 | 450 | 14.10 | 308 | 1954 | 6.75 / 575.87 | 6 | 52 |
Average= | 6.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.68 | 60 | 14.37 | 371 | 320 | 0.32 / 562.51 | 6 | 8 |
2 | 7 | 2015.36 | 106 | 11.67 | 1846 | 2284 | 2.60 / 564.80 | 8 | 30 |
3 | 13 | 1917.96 | 36 | 12.76 | 1801 | 827 | 3.43 / 565.62 | 5 | 38 |
4 | 13 | 1269.92 | 36 | 13.23 | 1343 | 640 | 4.07 / 566.26 | 5 | 44 |
5 | 13 | 965.84 | 36 | 13.44 | 1123 | 543 | 4.61 / 566.81 | 5 | 49 |
6 | 13 | 100.24 | 36 | 14.23 | 402 | 206 | 4.82 / 567.01 | 6 | 40 |
7 | 13 | 10.08 | 36 | 14.31 | 323 | 166 | 4.99 / 567.18 | 6 | 40 |
8 | 8 | -0.20 | 450 | 14.06 | 306 | 1936 | 6.92 / 569.12 | 6 | 68 |
Average= | 6.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.64 | 59 | 14.38 | 378 | 321 | 0.32 / 556.46 | 6 | 8 |
2 | 3 | 1015.92 | 1 | 12.60 | 1170 | 15 | 0.34 / 556.48 | 5 | 7 |
3 | 7 | 1399.20 | 105 | 12.15 | 1408 | 1796 | 2.13 / 558.27 | 7 | 37 |
4 | 13 | 1324.56 | 36 | 13.01 | 1374 | 644 | 2.78 / 558.92 | 5 | 40 |
5 | 13 | 1128.04 | 36 | 13.25 | 1237 | 590 | 3.37 / 559.51 | 5 | 45 |
6 | 13 | 595.48 | 36 | 13.67 | 829 | 408 | 3.77 / 559.91 | 5 | 50 |
7 | 13 | 64.64 | 36 | 14.25 | 370 | 190 | 3.96 / 560.10 | 6 | 41 |
8 | 13 | 1.88 | 36 | 14.30 | 315 | 162 | 4.13 / 560.27 | 6 | 38 |
9 | 8 | -0.08 | 450 | 14.05 | 305 | 1928 | 6.05 / 562.19 | 6 | 72 |
Average= | 6.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.80 | 59 | 14.35 | 375 | 317 | 0.32 / 549.29 | 6 | 10 |
2 | 7 | 2016.32 | 106 | 11.61 | 1848 | 2274 | 2.59 / 551.56 | 10 | 29 |
3 | 13 | 1922.00 | 36 | 12.74 | 1799 | 825 | 3.42 / 552.39 | 5 | 34 |
4 | 13 | 1589.60 | 36 | 13.04 | 1575 | 739 | 4.16 / 553.13 | 5 | 40 |
5 | 13 | 914.20 | 36 | 13.46 | 1084 | 525 | 4.68 / 553.65 | 5 | 48 |
6 | 13 | 468.76 | 36 | 13.82 | 724 | 360 | 5.04 / 554.01 | 5 | 50 |
7 | 13 | 24.76 | 36 | 14.29 | 338 | 174 | 5.22 / 554.19 | 6 | 41 |
8 | 8 | -0.40 | 450 | 14.05 | 309 | 1954 | 7.17 / 556.14 | 6 | 71 |
Average= | 6.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.32 | 59 | 14.34 | 379 | 321 | 0.32 / 543.52 | 6 | 8 |
2 | 7 | 1171.40 | 105 | 12.20 | 1247 | 1597 | 1.92 / 545.12 | 8 | 33 |
3 | 13 | 1118.68 | 36 | 13.08 | 1227 | 578 | 2.50 / 545.70 | 5 | 41 |
4 | 13 | 1032.24 | 36 | 13.24 | 1163 | 554 | 3.05 / 546.25 | 5 | 44 |
5 | 13 | 619.08 | 36 | 13.62 | 849 | 416 | 3.47 / 546.67 | 5 | 50 |
6 | 13 | 39.64 | 36 | 14.25 | 353 | 181 | 3.65 / 546.85 | 6 | 43 |
7 | 13 | 21.36 | 36 | 14.15 | 335 | 171 | 3.82 / 547.02 | 6 | 41 |
8 | 8 | -0.24 | 450 | 14.03 | 309 | 1951 | 5.77 / 548.97 | 6 | 64 |
Average= | 6.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.04 | 59 | 14.34 | 373 | 316 | 0.32 / 537.67 | 6 | 9 |
2 | 7 | 1219.60 | 105 | 12.15 | 1279 | 1632 | 1.95 / 539.30 | 9 | 38 |
3 | 13 | 1166.08 | 36 | 13.09 | 1262 | 595 | 2.54 / 539.89 | 5 | 44 |
4 | 13 | 1073.28 | 36 | 13.24 | 1195 | 570 | 3.11 / 540.46 | 5 | 44 |
5 | 13 | 651.60 | 36 | 13.61 | 880 | 431 | 3.54 / 540.90 | 5 | 50 |
6 | 13 | 40.76 | 36 | 14.26 | 355 | 182 | 3.72 / 541.08 | 6 | 41 |
7 | 13 | 6.32 | 36 | 14.22 | 323 | 165 | 3.89 / 541.24 | 6 | 42 |
8 | 8 | -0.36 | 450 | 14.00 | 311 | 1959 | 5.85 / 543.20 | 6 | 66 |
Average= | 6.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.28 | 59 | 14.35 | 384 | 325 | 0.33 / 532.13 | 6 | 8 |
2 | 7 | 1098.40 | 105 | 12.33 | 1189 | 1539 | 1.86 / 533.67 | 5 | 39 |
3 | 13 | 1048.72 | 36 | 13.18 | 1175 | 558 | 2.42 / 534.22 | 5 | 44 |
4 | 13 | 960.00 | 36 | 13.33 | 1110 | 533 | 2.95 / 534.76 | 5 | 47 |
5 | 13 | 654.16 | 36 | 13.62 | 879 | 431 | 3.39 / 535.19 | 5 | 49 |
6 | 13 | 100.20 | 36 | 14.21 | 402 | 206 | 3.59 / 535.39 | 5 | 43 |
7 | 8 | -0.16 | 450 | 14.05 | 310 | 1960 | 5.55 / 537.35 | 6 | 58 |
Average= | 6.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.92 | 59 | 14.35 | 380 | 322 | 0.32 / 526.34 | 6 | 9 |
2 | 7 | 1195.28 | 105 | 12.31 | 1266 | 1636 | 1.96 / 527.97 | 9 | 39 |
3 | 13 | 1139.80 | 36 | 13.17 | 1244 | 590 | 2.55 / 528.56 | 5 | 42 |
4 | 13 | 1043.88 | 36 | 13.32 | 1176 | 564 | 3.11 / 529.13 | 5 | 46 |
5 | 13 | 504.16 | 36 | 13.78 | 758 | 376 | 3.49 / 529.50 | 5 | 50 |
6 | 13 | 21.52 | 36 | 14.30 | 337 | 173 | 3.66 / 529.68 | 6 | 40 |
7 | 13 | 9.92 | 36 | 14.17 | 324 | 165 | 3.83 / 529.84 | 6 | 42 |
8 | 8 | -0.24 | 450 | 14.00 | 311 | 1959 | 5.79 / 531.80 | 6 | 71 |
Average= | 6.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.40 | 59 | 14.36 | 375 | 318 | 0.32 / 520.23 | 6 | 9 |
2 | 7 | 1385.68 | 105 | 12.25 | 1401 | 1802 | 2.12 / 522.03 | 9 | 37 |
3 | 13 | 1314.72 | 36 | 13.12 | 1371 | 648 | 2.77 / 522.68 | 5 | 44 |
4 | 13 | 1216.48 | 36 | 13.25 | 1303 | 622 | 3.39 / 523.30 | 5 | 45 |
5 | 13 | 572.16 | 36 | 13.75 | 815 | 403 | 3.79 / 523.70 | 5 | 51 |
6 | 13 | 31.64 | 36 | 14.29 | 348 | 179 | 3.97 / 523.88 | 6 | 43 |
7 | 13 | 18.00 | 36 | 14.16 | 334 | 170 | 4.14 / 524.05 | 6 | 42 |
8 | 8 | -0.16 | 450 | 13.98 | 312 | 1963 | 6.10 / 526.02 | 6 | 71 |
Average= | 6.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.40 | 59 | 14.38 | 382 | 324 | 0.32 / 513.91 | 6 | 9 |
2 | 7 | 1567.68 | 106 | 12.17 | 1532 | 1976 | 2.30 / 515.89 | 9 | 36 |
3 | 13 | 1481.04 | 36 | 13.08 | 1488 | 701 | 3.00 / 516.59 | 5 | 43 |
4 | 13 | 1182.72 | 36 | 13.36 | 1286 | 619 | 3.62 / 517.21 | 5 | 47 |
5 | 13 | 573.52 | 36 | 13.78 | 817 | 405 | 4.02 / 517.61 | 5 | 51 |
6 | 13 | 31.24 | 36 | 14.30 | 348 | 179 | 4.20 / 517.79 | 5 | 42 |
7 | 13 | 2.60 | 36 | 14.24 | 322 | 165 | 4.37 / 517.96 | 6 | 39 |
8 | 8 | -0.28 | 450 | 14.01 | 310 | 1954 | 6.32 / 519.91 | 6 | 72 |
Average= | 6.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.28 | 59 | 14.38 | 375 | 318 | 0.32 / 507.21 | 6 | 11 |
2 | 7 | 1912.00 | 106 | 12.03 | 1777 | 2266 | 2.58 / 509.47 | 11 | 34 |
3 | 13 | 1811.28 | 36 | 12.98 | 1724 | 806 | 3.39 / 510.28 | 5 | 38 |
4 | 13 | 1188.88 | 36 | 13.40 | 1293 | 624 | 4.01 / 510.90 | 5 | 45 |
5 | 13 | 872.36 | 36 | 13.59 | 1057 | 517 | 4.53 / 511.42 | 5 | 49 |
6 | 13 | 44.24 | 36 | 14.31 | 360 | 185 | 4.72 / 511.60 | 6 | 41 |
7 | 8 | -0.12 | 450 | 14.08 | 313 | 1983 | 6.70 / 513.59 | 6 | 61 |
Average= | 6.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.68 | 59 | 14.39 | 373 | 317 | 0.32 / 500.26 | 6 | 11 |
2 | 7 | 2005.40 | 106 | 11.99 | 1843 | 2342 | 2.66 / 502.60 | 11 | 32 |
3 | 13 | 1905.80 | 36 | 12.94 | 1791 | 834 | 3.49 / 503.43 | 5 | 38 |
4 | 13 | 1266.08 | 36 | 13.38 | 1338 | 644 | 4.14 / 504.08 | 5 | 46 |
5 | 13 | 841.08 | 36 | 13.63 | 1030 | 505 | 4.64 / 504.58 | 5 | 48 |
6 | 13 | 82.84 | 36 | 14.29 | 385 | 198 | 4.84 / 504.78 | 5 | 40 |
7 | 13 | 3.24 | 36 | 14.34 | 317 | 164 | 5.00 / 504.95 | 6 | 36 |
8 | 8 | -0.20 | 450 | 14.06 | 307 | 1942 | 6.95 / 506.89 | 6 | 69 |
Average= | 6.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.96 | 58 | 14.35 | 391 | 325 | 0.33 / 493.43 | 6 | 13 |
2 | 7 | 2005.64 | 105 | 11.98 | 1845 | 2321 | 2.65 / 495.75 | 5 | 32 |
3 | 13 | 1803.80 | 36 | 13.06 | 1722 | 810 | 3.46 / 496.56 | 5 | 39 |
4 | 13 | 1384.88 | 36 | 13.33 | 1429 | 686 | 4.14 / 497.24 | 5 | 45 |
5 | 13 | 849.16 | 36 | 13.63 | 1034 | 507 | 4.65 / 497.75 | 5 | 51 |
6 | 13 | 93.64 | 36 | 14.26 | 403 | 207 | 4.86 / 497.96 | 5 | 42 |
7 | 8 | -0.16 | 450 | 14.05 | 314 | 1985 | 6.84 / 499.94 | 6 | 65 |
Average= | 6.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.64 | 58 | 14.37 | 382 | 318 | 0.32 / 486.70 | 6 | 12 |
2 | 7 | 1941.48 | 106 | 12.02 | 1794 | 2286 | 2.60 / 488.99 | 12 | 33 |
3 | 13 | 1839.08 | 36 | 12.98 | 1742 | 814 | 3.42 / 489.80 | 5 | 38 |
4 | 13 | 1298.60 | 36 | 13.38 | 1366 | 658 | 4.08 / 490.46 | 5 | 46 |
5 | 13 | 780.52 | 36 | 13.68 | 981 | 483 | 4.56 / 490.94 | 5 | 50 |
6 | 13 | 28.92 | 36 | 14.34 | 341 | 176 | 4.74 / 491.12 | 6 | 40 |
7 | 8 | 0.12 | 450 | 14.05 | 313 | 1979 | 6.71 / 493.10 | 6 | 67 |
Average= | 6.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.64 | 58 | 14.37 | 389 | 324 | 0.32 / 479.95 | 6 | 14 |
2 | 7 | 2008.32 | 106 | 11.97 | 1845 | 2341 | 2.67 / 482.29 | 14 | 31 |
3 | 13 | 1796.68 | 36 | 13.09 | 1720 | 811 | 3.48 / 483.11 | 5 | 38 |
4 | 13 | 1183.40 | 36 | 13.46 | 1285 | 623 | 4.10 / 483.73 | 5 | 45 |
5 | 13 | 760.36 | 36 | 13.70 | 968 | 477 | 4.58 / 484.21 | 5 | 50 |
6 | 13 | 104.24 | 36 | 14.28 | 405 | 208 | 4.78 / 484.41 | 5 | 40 |
7 | 8 | 0.24 | 450 | 14.09 | 311 | 1972 | 6.76 / 486.39 | 6 | 62 |
Average= | 6.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.48 | 58 | 14.36 | 387 | 322 | 0.32 / 473.14 | 6 | 13 |
2 | 7 | 2010.20 | 105 | 12.00 | 1845 | 2325 | 2.65 / 475.47 | 5 | 33 |
3 | 13 | 1714.60 | 36 | 13.16 | 1665 | 789 | 3.44 / 476.26 | 5 | 40 |
4 | 13 | 1303.00 | 36 | 13.41 | 1374 | 663 | 4.10 / 476.92 | 5 | 46 |
5 | 13 | 880.36 | 36 | 13.65 | 1056 | 519 | 4.62 / 477.44 | 5 | 48 |
6 | 13 | 104.76 | 36 | 14.29 | 407 | 209 | 4.83 / 477.65 | 5 | 41 |
7 | 8 | -0.24 | 450 | 14.11 | 312 | 1981 | 6.81 / 479.63 | 6 | 58 |
Average= | 6.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.60 | 58 | 14.36 | 388 | 323 | 0.32 / 466.36 | 6 | 14 |
2 | 7 | 2004.64 | 105 | 12.02 | 1842 | 2325 | 2.65 / 468.68 | 14 | 32 |
3 | 13 | 1808.68 | 36 | 13.12 | 1732 | 818 | 3.47 / 469.50 | 5 | 39 |
4 | 13 | 1402.68 | 36 | 13.38 | 1450 | 698 | 4.16 / 470.20 | 5 | 44 |
5 | 13 | 746.20 | 36 | 13.74 | 954 | 472 | 4.64 / 470.67 | 5 | 50 |
6 | 13 | 48.12 | 36 | 14.35 | 356 | 184 | 4.82 / 470.86 | 6 | 38 |
7 | 8 | -0.12 | 450 | 14.09 | 310 | 1966 | 6.79 / 472.82 | 6 | 59 |
Average= | 6.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.92 | 56 | 14.39 | 391 | 315 | 0.32 / 459.52 | 6 | 14 |
2 | 3 | 1039.40 | 2 | 13.45 | 1191 | 32 | 0.35 / 459.55 | 5 | 31 |
3 | 7 | 2005.20 | 105 | 12.04 | 1837 | 2322 | 2.67 / 461.88 | 31 | 32 |
4 | 13 | 1803.44 | 36 | 13.13 | 1727 | 816 | 3.49 / 462.69 | 5 | 40 |
5 | 13 | 1276.80 | 36 | 13.46 | 1356 | 657 | 4.14 / 463.35 | 5 | 47 |
6 | 13 | 858.04 | 36 | 13.68 | 1042 | 513 | 4.66 / 463.86 | 5 | 50 |
7 | 13 | 92.96 | 36 | 14.32 | 395 | 204 | 4.86 / 464.07 | 6 | 39 |
8 | 8 | 0.04 | 450 | 14.11 | 310 | 1968 | 6.83 / 466.04 | 6 | 61 |
Average= | 6.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.00 | 59 | 14.38 | 387 | 328 | 0.33 / 452.71 | 6 | 14 |
2 | 3 | 962.60 | -1 | 14.38 | 387 | 0 | 0.00 / 452.71 | 6 | 14 |
3 | 7 | 2012.40 | 105 | 12.04 | 1849 | 2338 | 2.67 / 455.05 | 14 | 32 |
4 | 13 | 1812.24 | 36 | 13.14 | 1733 | 820 | 3.49 / 455.87 | 5 | 39 |
5 | 13 | 1276.08 | 36 | 13.46 | 1350 | 654 | 4.14 / 456.52 | 5 | 46 |
6 | 13 | 854.00 | 36 | 13.69 | 1038 | 512 | 4.65 / 457.03 | 5 | 50 |
7 | 13 | 85.00 | 36 | 14.33 | 387 | 200 | 4.85 / 457.23 | 6 | 39 |
8 | 8 | -0.08 | 450 | 14.11 | 311 | 1975 | 6.83 / 459.21 | 6 | 58 |
Average= | 6.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.76 | 59 | 14.37 | 398 | 337 | 0.34 / 446.00 | 6 | 14 |
2 | 7 | 2005.48 | 105 | 12.08 | 1841 | 2335 | 2.67 / 448.34 | 14 | 33 |
3 | 13 | 1701.40 | 36 | 13.24 | 1650 | 786 | 3.46 / 449.12 | 5 | 41 |
4 | 13 | 1285.24 | 36 | 13.48 | 1352 | 656 | 4.12 / 449.78 | 5 | 45 |
5 | 13 | 666.76 | 36 | 13.82 | 886 | 441 | 4.56 / 450.22 | 5 | 51 |
6 | 13 | 62.32 | 36 | 14.35 | 366 | 189 | 4.74 / 450.41 | 6 | 40 |
7 | 8 | 0.00 | 450 | 14.09 | 311 | 1972 | 6.72 / 452.38 | 6 | 57 |
Average= | 6.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.20 | 58 | 14.35 | 397 | 330 | 0.33 / 439.17 | 6 | 16 |
2 | 3 | 1026.24 | 1 | 13.42 | 1182 | 16 | 0.35 / 439.18 | 5 | 25 |
3 | 7 | 2004.36 | 105 | 12.12 | 1842 | 2344 | 2.69 / 441.53 | 25 | 33 |
4 | 13 | 1803.68 | 36 | 13.19 | 1720 | 817 | 3.51 / 442.34 | 5 | 38 |
5 | 13 | 1270.80 | 36 | 13.49 | 1350 | 656 | 4.16 / 443.00 | 5 | 46 |
6 | 13 | 749.48 | 36 | 13.77 | 957 | 474 | 4.64 / 443.47 | 5 | 51 |
7 | 13 | 92.00 | 36 | 14.32 | 396 | 204 | 4.84 / 443.68 | 5 | 41 |
8 | 8 | -0.08 | 450 | 14.10 | 313 | 1986 | 6.83 / 445.66 | 6 | 64 |
Average= | 6.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.96 | 58 | 14.37 | 394 | 328 | 0.33 / 432.25 | 6 | 15 |
2 | 7 | 2005.12 | 106 | 12.14 | 1844 | 2373 | 2.70 / 434.62 | 15 | 33 |
3 | 13 | 1908.40 | 36 | 13.07 | 1790 | 842 | 3.54 / 435.46 | 5 | 38 |
4 | 13 | 1263.28 | 36 | 13.50 | 1342 | 652 | 4.20 / 436.11 | 5 | 47 |
5 | 13 | 940.76 | 36 | 13.67 | 1108 | 545 | 4.74 / 436.66 | 5 | 49 |
6 | 13 | 32.16 | 36 | 14.36 | 348 | 180 | 4.92 / 436.84 | 6 | 41 |
7 | 8 | 0.04 | 450 | 14.05 | 316 | 1998 | 6.92 / 438.84 | 6 | 64 |
Average= | 6.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.20 | 58 | 14.38 | 392 | 327 | 0.33 / 425.37 | 6 | 15 |
2 | 7 | 2003.12 | 106 | 12.16 | 1845 | 2378 | 2.71 / 427.75 | 15 | 33 |
3 | 13 | 1903.04 | 36 | 13.09 | 1788 | 843 | 3.55 / 428.59 | 5 | 39 |
4 | 13 | 1357.76 | 36 | 13.47 | 1408 | 683 | 4.23 / 429.28 | 5 | 45 |
5 | 13 | 705.08 | 36 | 13.81 | 924 | 459 | 4.69 / 429.74 | 5 | 50 |
6 | 13 | 32.48 | 36 | 14.36 | 346 | 179 | 4.87 / 429.91 | 6 | 40 |
7 | 8 | 0.08 | 450 | 14.05 | 317 | 2004 | 6.87 / 431.92 | 6 | 64 |
Average= | 6.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.68 | 58 | 14.40 | 392 | 327 | 0.33 / 418.57 | 6 | 14 |
2 | 7 | 2012.52 | 106 | 12.20 | 1851 | 2394 | 2.72 / 420.96 | 14 | 34 |
3 | 13 | 1714.80 | 36 | 13.29 | 1658 | 793 | 3.51 / 421.75 | 5 | 41 |
4 | 13 | 1298.16 | 36 | 13.51 | 1366 | 664 | 4.18 / 422.42 | 5 | 47 |
5 | 13 | 747.48 | 36 | 13.79 | 953 | 473 | 4.65 / 422.89 | 5 | 51 |
6 | 13 | 45.48 | 36 | 14.37 | 353 | 183 | 4.83 / 423.07 | 6 | 40 |
7 | 8 | 0.08 | 450 | 14.10 | 311 | 1973 | 6.81 / 425.05 | 6 | 66 |
Average= | 6.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.68 | 58 | 14.40 | 384 | 321 | 0.32 / 411.80 | 6 | 16 |
2 | 7 | 2012.96 | 106 | 12.24 | 1850 | 2400 | 2.72 / 414.20 | 16 | 34 |
3 | 13 | 1709.84 | 36 | 13.31 | 1653 | 792 | 3.51 / 415.00 | 5 | 41 |
4 | 13 | 1182.04 | 36 | 13.58 | 1281 | 626 | 4.14 / 415.62 | 5 | 48 |
5 | 13 | 771.88 | 36 | 13.79 | 973 | 483 | 4.62 / 416.11 | 5 | 49 |
6 | 13 | 23.76 | 36 | 14.40 | 330 | 171 | 4.79 / 416.28 | 6 | 39 |
7 | 8 | -0.04 | 450 | 14.10 | 309 | 1961 | 6.75 / 418.24 | 6 | 64 |
Average= | 6.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.56 | 58 | 14.40 | 393 | 328 | 0.33 / 404.87 | 6 | 15 |
2 | 7 | 2005.84 | 106 | 12.29 | 1849 | 2409 | 2.74 / 407.28 | 5 | 34 |
3 | 13 | 1803.12 | 36 | 13.27 | 1717 | 820 | 3.56 / 408.10 | 5 | 39 |
4 | 13 | 1476.04 | 36 | 13.46 | 1496 | 725 | 4.28 / 408.83 | 5 | 44 |
5 | 13 | 810.60 | 36 | 13.77 | 1005 | 498 | 4.78 / 409.32 | 5 | 51 |
6 | 13 | 66.24 | 36 | 14.36 | 371 | 192 | 4.97 / 409.52 | 6 | 40 |
7 | 8 | 0.04 | 450 | 14.11 | 310 | 1968 | 6.94 / 411.48 | 6 | 69 |
Average= | 6.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.96 | 58 | 14.43 | 378 | 316 | 0.32 / 398.31 | 6 | 13 |
2 | 7 | 2004.32 | 106 | 12.32 | 1845 | 2409 | 2.73 / 400.72 | 13 | 33 |
3 | 13 | 1702.72 | 36 | 13.34 | 1655 | 795 | 3.52 / 401.51 | 5 | 40 |
4 | 13 | 1184.72 | 36 | 13.60 | 1284 | 629 | 4.15 / 402.14 | 5 | 46 |
5 | 13 | 663.40 | 36 | 13.86 | 884 | 441 | 4.59 / 402.58 | 5 | 51 |
6 | 8 | 0.12 | 450 | 14.12 | 309 | 1963 | 6.55 / 404.54 | 6 | 62 |
Average= | 6.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.08 | 58 | 14.43 | 381 | 319 | 0.32 / 391.43 | 6 | 14 |
2 | 7 | 2013.60 | 105 | 12.35 | 1852 | 2402 | 2.72 / 393.84 | 14 | 34 |
3 | 13 | 1820.80 | 36 | 13.27 | 1735 | 829 | 3.55 / 394.67 | 5 | 41 |
4 | 13 | 1388.20 | 36 | 13.51 | 1433 | 697 | 4.25 / 395.36 | 5 | 46 |
5 | 13 | 730.00 | 36 | 13.83 | 937 | 467 | 4.71 / 395.83 | 5 | 50 |
6 | 13 | 80.20 | 36 | 14.36 | 382 | 197 | 4.91 / 396.03 | 6 | 41 |
7 | 8 | 0.16 | 450 | 14.12 | 309 | 1963 | 6.87 / 397.99 | 6 | 67 |
Average= | 6.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.52 | 58 | 14.43 | 381 | 319 | 0.32 / 384.69 | 6 | 13 |
2 | 7 | 2003.08 | 106 | 12.37 | 1844 | 2418 | 2.74 / 387.10 | 13 | 35 |
3 | 13 | 1902.68 | 36 | 13.16 | 1790 | 848 | 3.58 / 387.95 | 5 | 40 |
4 | 13 | 1162.72 | 36 | 13.60 | 1273 | 623 | 4.21 / 388.58 | 5 | 48 |
5 | 13 | 545.64 | 36 | 13.96 | 788 | 396 | 4.60 / 388.97 | 5 | 50 |
6 | 13 | 49.20 | 36 | 14.38 | 357 | 185 | 4.79 / 389.16 | 6 | 41 |
7 | 8 | -0.24 | 450 | 14.09 | 309 | 1959 | 6.75 / 391.12 | 6 | 61 |
Average= | 6.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.04 | 58 | 14.45 | 382 | 320 | 0.32 / 377.96 | 6 | 13 |
2 | 7 | 2004.60 | 106 | 12.40 | 1848 | 2429 | 2.75 / 380.39 | 13 | 33 |
3 | 13 | 1604.24 | 36 | 13.40 | 1588 | 766 | 3.52 / 381.15 | 5 | 42 |
4 | 13 | 1109.76 | 36 | 13.64 | 1229 | 603 | 4.12 / 381.76 | 5 | 47 |
5 | 13 | 692.20 | 36 | 13.86 | 914 | 456 | 4.57 / 382.21 | 5 | 51 |
6 | 13 | 51.04 | 36 | 14.38 | 361 | 187 | 4.76 / 382.40 | 6 | 42 |
7 | 8 | -0.04 | 450 | 14.12 | 310 | 1970 | 6.73 / 384.37 | 6 | 62 |
Average= | 6.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.52 | 58 | 14.44 | 389 | 326 | 0.33 / 371.17 | 6 | 12 |
2 | 7 | 2006.92 | 105 | 12.41 | 1848 | 2408 | 2.73 / 373.58 | 12 | 35 |
3 | 13 | 1908.80 | 36 | 13.18 | 1793 | 851 | 3.58 / 374.43 | 5 | 40 |
4 | 13 | 1136.36 | 36 | 13.62 | 1254 | 615 | 4.20 / 375.04 | 5 | 47 |
5 | 13 | 626.32 | 36 | 13.89 | 864 | 432 | 4.63 / 375.48 | 5 | 52 |
6 | 13 | 39.64 | 36 | 14.39 | 352 | 182 | 4.81 / 375.66 | 6 | 42 |
7 | 8 | 0.00 | 450 | 14.09 | 312 | 1978 | 6.79 / 377.64 | 6 | 64 |
Average= | 6.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.44 | 58 | 14.47 | 380 | 319 | 0.32 / 364.26 | 6 | 11 |
2 | 7 | 2005.72 | 105 | 12.42 | 1846 | 2407 | 2.73 / 366.67 | 11 | 35 |
3 | 13 | 1916.76 | 36 | 13.18 | 1799 | 854 | 3.58 / 367.53 | 5 | 40 |
4 | 13 | 1259.92 | 36 | 13.58 | 1334 | 652 | 4.23 / 368.18 | 5 | 46 |
5 | 13 | 826.24 | 36 | 13.78 | 1019 | 506 | 4.74 / 368.68 | 5 | 51 |
6 | 13 | 81.80 | 36 | 14.35 | 387 | 200 | 4.94 / 368.88 | 5 | 43 |
7 | 8 | 0.00 | 450 | 14.15 | 308 | 1961 | 6.90 / 370.84 | 6 | 58 |
Average= | 6.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.64 | 58 | 14.49 | 372 | 313 | 0.31 / 357.25 | 6 | 10 |
2 | 7 | 2010.32 | 105 | 12.44 | 1849 | 2415 | 2.73 / 359.67 | 5 | 34 |
3 | 13 | 1909.80 | 36 | 13.19 | 1792 | 851 | 3.58 / 360.52 | 5 | 38 |
4 | 13 | 1369.72 | 36 | 13.54 | 1419 | 692 | 4.27 / 361.21 | 5 | 44 |
5 | 13 | 692.88 | 36 | 13.86 | 914 | 456 | 4.73 / 361.66 | 5 | 51 |
6 | 13 | 66.84 | 36 | 14.37 | 374 | 193 | 4.92 / 361.86 | 5 | 43 |
7 | 13 | 2.36 | 36 | 14.39 | 315 | 163 | 5.08 / 362.02 | 6 | 40 |
8 | 8 | -0.32 | 450 | 14.12 | 303 | 1925 | 7.01 / 363.95 | 6 | 76 |
Average= | 6.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.52 | 58 | 14.49 | 372 | 313 | 0.31 / 350.40 | 6 | 9 |
2 | 7 | 2013.80 | 105 | 12.45 | 1852 | 2421 | 2.73 / 352.82 | 9 | 35 |
3 | 13 | 1706.20 | 36 | 13.37 | 1659 | 799 | 3.53 / 353.62 | 5 | 43 |
4 | 13 | 1086.96 | 36 | 13.66 | 1213 | 597 | 4.13 / 354.21 | 5 | 47 |
5 | 13 | 571.68 | 36 | 13.95 | 812 | 408 | 4.54 / 354.62 | 5 | 52 |
6 | 13 | 61.52 | 36 | 14.39 | 369 | 191 | 4.73 / 354.81 | 6 | 42 |
7 | 13 | 30.92 | 36 | 14.31 | 340 | 175 | 4.90 / 354.99 | 6 | 43 |
8 | 8 | -0.12 | 450 | 14.12 | 307 | 1951 | 6.85 / 356.94 | 6 | 67 |
Average= | 6.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.80 | 58 | 14.53 | 367 | 309 | 0.31 / 343.41 | 6 | 9 |
2 | 7 | 2007.20 | 105 | 12.46 | 1850 | 2420 | 2.73 / 345.83 | 9 | 35 |
3 | 13 | 1806.68 | 36 | 13.31 | 1728 | 828 | 3.56 / 346.65 | 5 | 40 |
4 | 13 | 1252.40 | 36 | 13.59 | 1337 | 654 | 4.21 / 347.31 | 5 | 48 |
5 | 13 | 822.68 | 36 | 13.80 | 1018 | 506 | 4.72 / 347.81 | 5 | 51 |
6 | 13 | 36.44 | 36 | 14.43 | 344 | 179 | 4.90 / 347.99 | 6 | 39 |
7 | 13 | 19.28 | 36 | 14.32 | 328 | 169 | 5.07 / 348.16 | 6 | 40 |
8 | 8 | -0.04 | 450 | 14.15 | 302 | 1923 | 6.99 / 350.08 | 6 | 70 |
Average= | 6.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.60 | 58 | 14.53 | 371 | 313 | 0.31 / 336.64 | 6 | 9 |
2 | 7 | 2004.88 | 106 | 12.45 | 1849 | 2440 | 2.75 / 339.08 | 9 | 31 |
3 | 13 | 1710.04 | 36 | 13.37 | 1659 | 799 | 3.55 / 339.88 | 5 | 40 |
4 | 13 | 1195.24 | 36 | 13.62 | 1295 | 635 | 4.19 / 340.51 | 5 | 47 |
5 | 13 | 663.04 | 36 | 13.89 | 888 | 444 | 4.63 / 340.95 | 5 | 51 |
6 | 13 | 45.88 | 36 | 14.42 | 354 | 184 | 4.81 / 341.14 | 6 | 41 |
7 | 8 | -0.16 | 450 | 14.17 | 307 | 1958 | 6.77 / 343.10 | 6 | 65 |
Average= | 6.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.40 | 58 | 14.53 | 372 | 313 | 0.31 / 329.85 | 6 | 8 |
2 | 7 | 2012.04 | 105 | 12.45 | 1852 | 2421 | 2.73 / 332.27 | 8 | 33 |
3 | 13 | 1700.96 | 36 | 13.37 | 1650 | 794 | 3.53 / 333.06 | 5 | 40 |
4 | 13 | 1185.84 | 36 | 13.62 | 1288 | 632 | 4.16 / 333.69 | 5 | 47 |
5 | 13 | 762.40 | 36 | 13.84 | 971 | 484 | 4.64 / 334.18 | 5 | 51 |
6 | 13 | 43.84 | 36 | 14.42 | 354 | 184 | 4.83 / 334.36 | 6 | 41 |
7 | 8 | -0.28 | 450 | 14.16 | 308 | 1963 | 6.79 / 336.32 | 6 | 60 |
Average= | 6.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.16 | 58 | 14.51 | 371 | 312 | 0.31 / 323.03 | 6 | 8 |
2 | 7 | 2003.80 | 106 | 12.42 | 1848 | 2433 | 2.75 / 325.47 | 8 | 35 |
3 | 13 | 1703.60 | 36 | 13.36 | 1646 | 792 | 3.54 / 326.26 | 5 | 43 |
4 | 13 | 1269.92 | 36 | 13.58 | 1344 | 657 | 4.19 / 326.92 | 5 | 47 |
5 | 13 | 829.64 | 36 | 13.80 | 1019 | 506 | 4.70 / 327.42 | 5 | 51 |
6 | 13 | 40.08 | 36 | 14.43 | 344 | 179 | 4.88 / 327.60 | 6 | 40 |
7 | 8 | 0.00 | 450 | 14.18 | 303 | 1933 | 6.81 / 329.53 | 6 | 63 |
Average= | 6.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.56 | 58 | 14.50 | 368 | 309 | 0.31 / 316.10 | 6 | 10 |
2 | 7 | 2013.28 | 105 | 12.41 | 1851 | 2412 | 2.72 / 318.51 | 10 | 33 |
3 | 13 | 1816.92 | 36 | 13.29 | 1736 | 831 | 3.55 / 319.34 | 5 | 38 |
4 | 13 | 1184.20 | 36 | 13.61 | 1289 | 632 | 4.18 / 319.97 | 5 | 46 |
5 | 13 | 656.16 | 36 | 13.90 | 889 | 445 | 4.63 / 320.42 | 5 | 51 |
6 | 13 | 47.52 | 36 | 14.43 | 356 | 185 | 4.81 / 320.60 | 6 | 41 |
7 | 13 | 9.32 | 36 | 14.37 | 321 | 166 | 4.98 / 320.77 | 6 | 41 |
8 | 8 | -0.24 | 450 | 14.15 | 307 | 1955 | 6.93 / 322.72 | 6 | 68 |
Average= | 6.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.36 | 58 | 14.50 | 376 | 316 | 0.32 / 309.08 | 6 | 9 |
2 | 7 | 2007.00 | 106 | 12.42 | 1849 | 2434 | 2.75 / 311.51 | 9 | 34 |
3 | 13 | 1911.04 | 36 | 13.16 | 1800 | 853 | 3.60 / 312.36 | 5 | 40 |
4 | 13 | 1263.84 | 36 | 13.57 | 1344 | 657 | 4.26 / 313.02 | 5 | 46 |
5 | 13 | 709.08 | 36 | 13.87 | 924 | 461 | 4.72 / 313.48 | 5 | 51 |
6 | 13 | 63.00 | 36 | 14.41 | 369 | 191 | 4.91 / 313.67 | 6 | 42 |
7 | 13 | 15.16 | 36 | 14.38 | 327 | 169 | 5.08 / 313.84 | 6 | 42 |
8 | 8 | -0.24 | 450 | 14.13 | 306 | 1946 | 7.03 / 315.79 | 6 | 81 |
Average= | 6.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.12 | 58 | 14.50 | 370 | 311 | 0.31 / 302.08 | 6 | 10 |
2 | 7 | 2010.00 | 105 | 12.44 | 1850 | 2416 | 2.73 / 304.49 | 10 | 34 |
3 | 13 | 1914.44 | 36 | 13.16 | 1799 | 852 | 3.58 / 305.35 | 5 | 40 |
4 | 13 | 1456.72 | 36 | 13.50 | 1478 | 718 | 4.30 / 306.06 | 5 | 44 |
5 | 13 | 800.40 | 36 | 13.82 | 1001 | 498 | 4.80 / 306.56 | 5 | 50 |
6 | 13 | 140.92 | 36 | 14.35 | 437 | 226 | 5.02 / 306.79 | 5 | 43 |
7 | 8 | -0.24 | 450 | 14.18 | 309 | 1972 | 6.99 / 308.76 | 6 | 60 |
Average= | 6.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.64 | 58 | 14.50 | 377 | 317 | 0.32 / 295.21 | 6 | 9 |
2 | 7 | 2013.40 | 106 | 12.45 | 1852 | 2444 | 2.76 / 297.65 | 5 | 35 |
3 | 13 | 1710.24 | 36 | 13.36 | 1661 | 799 | 3.56 / 298.45 | 5 | 42 |
4 | 13 | 1408.00 | 36 | 13.53 | 1449 | 706 | 4.27 / 299.16 | 5 | 45 |
5 | 13 | 735.36 | 36 | 13.87 | 946 | 472 | 4.74 / 299.63 | 5 | 52 |
6 | 13 | 41.68 | 36 | 14.45 | 347 | 181 | 4.92 / 299.81 | 6 | 41 |
7 | 8 | -0.04 | 450 | 14.19 | 306 | 1954 | 6.87 / 301.77 | 6 | 61 |
Average= | 6.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.44 | 58 | 14.51 | 376 | 316 | 0.32 / 288.44 | 6 | 10 |
2 | 7 | 2013.72 | 105 | 12.48 | 1853 | 2428 | 2.74 / 290.87 | 10 | 34 |
3 | 13 | 1705.84 | 36 | 13.37 | 1661 | 799 | 3.54 / 291.67 | 5 | 42 |
4 | 13 | 1191.00 | 36 | 13.64 | 1280 | 629 | 4.17 / 292.30 | 5 | 46 |
5 | 13 | 667.04 | 36 | 13.92 | 892 | 447 | 4.62 / 292.74 | 5 | 51 |
6 | 13 | 46.44 | 36 | 14.44 | 356 | 185 | 4.80 / 292.93 | 5 | 42 |
7 | 8 | -0.32 | 450 | 14.17 | 308 | 1964 | 6.77 / 294.89 | 6 | 68 |
Average= | 6.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.72 | 58 | 14.48 | 378 | 317 | 0.32 / 281.58 | 6 | 11 |
2 | 7 | 2006.84 | 105 | 12.50 | 1847 | 2424 | 2.74 / 284.00 | 11 | 34 |
3 | 13 | 1813.04 | 36 | 13.33 | 1733 | 832 | 3.57 / 284.83 | 5 | 40 |
4 | 13 | 1165.16 | 36 | 13.65 | 1276 | 627 | 4.20 / 285.46 | 5 | 47 |
5 | 13 | 839.16 | 36 | 13.83 | 1031 | 513 | 4.71 / 285.97 | 5 | 49 |
6 | 13 | 38.08 | 36 | 14.47 | 349 | 182 | 4.90 / 286.15 | 6 | 40 |
7 | 8 | -0.04 | 450 | 14.18 | 309 | 1972 | 6.87 / 288.12 | 6 | 67 |
Average= | 6.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.52 | 58 | 14.48 | 395 | 332 | 0.33 / 274.63 | 6 | 12 |
2 | 7 | 2006.52 | 105 | 12.55 | 1850 | 2438 | 2.77 / 277.07 | 12 | 34 |
3 | 13 | 1707.72 | 36 | 13.41 | 1664 | 803 | 3.57 / 277.88 | 5 | 42 |
4 | 13 | 1373.80 | 36 | 13.59 | 1425 | 697 | 4.27 / 278.57 | 5 | 45 |
5 | 13 | 805.04 | 36 | 13.87 | 1006 | 502 | 4.77 / 279.08 | 5 | 51 |
6 | 13 | 44.56 | 36 | 14.47 | 355 | 185 | 4.96 / 279.26 | 5 | 41 |
7 | 8 | 0.04 | 450 | 14.18 | 313 | 1997 | 6.95 / 281.26 | 6 | 60 |
Average= | 6.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.72 | 58 | 14.49 | 384 | 323 | 0.32 / 267.76 | 6 | 12 |
2 | 7 | 2005.68 | 105 | 12.58 | 1850 | 2444 | 2.77 / 270.20 | 12 | 34 |
3 | 13 | 1600.00 | 36 | 13.48 | 1587 | 770 | 3.54 / 270.97 | 5 | 42 |
4 | 13 | 1501.40 | 36 | 13.51 | 1512 | 735 | 4.27 / 271.71 | 5 | 43 |
5 | 13 | 613.56 | 36 | 13.99 | 851 | 429 | 4.70 / 272.14 | 5 | 51 |
6 | 13 | 17.64 | 36 | 14.50 | 335 | 175 | 4.88 / 272.31 | 6 | 40 |
7 | 8 | -0.08 | 450 | 14.18 | 312 | 1991 | 6.87 / 274.30 | 6 | 66 |
Average= | 6.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.28 | 58 | 14.54 | 383 | 323 | 0.32 / 260.93 | 6 | 13 |
2 | 7 | 2014.84 | 106 | 12.63 | 1858 | 2487 | 2.81 / 263.41 | 13 | 34 |
3 | 13 | 1692.96 | 36 | 13.48 | 1651 | 801 | 3.61 / 264.21 | 5 | 42 |
4 | 13 | 1169.52 | 36 | 13.71 | 1279 | 631 | 4.24 / 264.84 | 5 | 47 |
5 | 13 | 538.56 | 36 | 14.07 | 786 | 398 | 4.64 / 265.24 | 5 | 49 |
6 | 13 | 38.20 | 36 | 14.50 | 352 | 184 | 4.82 / 265.43 | 6 | 40 |
7 | 8 | -0.16 | 450 | 14.18 | 315 | 2010 | 6.83 / 267.44 | 6 | 71 |
Average= | 6.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.56 | 58 | 14.52 | 398 | 335 | 0.34 / 253.93 | 6 | 13 |
2 | 3 | 1010.40 | 1 | 13.99 | 1166 | 16 | 0.35 / 253.94 | 5 | 6 |
3 | 7 | 2007.12 | 105 | 12.70 | 1852 | 2470 | 2.82 / 256.41 | 6 | 34 |
4 | 13 | 1809.20 | 36 | 13.45 | 1727 | 836 | 3.66 / 257.25 | 5 | 40 |
5 | 13 | 1264.44 | 36 | 13.69 | 1351 | 666 | 4.32 / 257.91 | 5 | 46 |
6 | 13 | 834.28 | 36 | 13.91 | 1027 | 514 | 4.84 / 258.43 | 5 | 50 |
7 | 13 | 0.96 | 36 | 14.55 | 323 | 169 | 5.01 / 258.60 | 6 | 38 |
8 | 8 | 0.00 | 450 | 14.18 | 314 | 2004 | 7.01 / 260.60 | 6 | 68 |
Average= | 6.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.80 | 57 | 14.53 | 386 | 320 | 0.32 / 246.98 | 6 | 13 |
2 | 7 | 2006.08 | 105 | 12.73 | 1850 | 2473 | 2.79 / 249.45 | 5 | 34 |
3 | 13 | 1908.08 | 36 | 13.36 | 1801 | 866 | 3.66 / 250.32 | 5 | 40 |
4 | 13 | 1234.48 | 36 | 13.73 | 1323 | 654 | 4.31 / 250.97 | 5 | 46 |
5 | 13 | 680.56 | 36 | 14.01 | 905 | 456 | 4.77 / 251.43 | 5 | 51 |
6 | 13 | 17.56 | 36 | 14.53 | 335 | 175 | 4.94 / 251.60 | 6 | 41 |
7 | 8 | -0.08 | 450 | 14.21 | 311 | 1989 | 6.93 / 253.59 | 6 | 68 |
Average= | 6.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.28 | 57 | 14.53 | 395 | 327 | 0.33 / 240.12 | 6 | 14 |
2 | 7 | 2004.68 | 106 | 12.77 | 1850 | 2504 | 2.83 / 242.63 | 5 | 34 |
3 | 13 | 1708.08 | 36 | 13.55 | 1663 | 811 | 3.64 / 243.44 | 5 | 40 |
4 | 13 | 1175.96 | 36 | 13.77 | 1281 | 635 | 4.28 / 244.07 | 5 | 47 |
5 | 13 | 557.44 | 36 | 14.10 | 803 | 408 | 4.69 / 244.48 | 5 | 49 |
6 | 13 | 9.52 | 36 | 14.56 | 326 | 171 | 4.86 / 244.65 | 6 | 40 |
7 | 8 | 0.08 | 450 | 14.21 | 314 | 2008 | 6.86 / 246.66 | 6 | 70 |
Average= | 6.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.40 | 57 | 14.53 | 390 | 323 | 0.32 / 233.47 | 6 | 14 |
2 | 7 | 2004.20 | 105 | 12.80 | 1854 | 2492 | 2.81 / 235.96 | 14 | 34 |
3 | 13 | 1601.88 | 36 | 13.60 | 1591 | 779 | 3.59 / 236.74 | 5 | 41 |
4 | 13 | 1178.52 | 36 | 13.77 | 1288 | 638 | 4.23 / 237.38 | 5 | 46 |
5 | 13 | 536.56 | 36 | 14.12 | 788 | 401 | 4.63 / 237.78 | 5 | 49 |
6 | 8 | -0.16 | 450 | 14.23 | 315 | 2017 | 6.65 / 239.79 | 6 | 55 |
Average= | 6.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.92 | 57 | 14.54 | 392 | 325 | 0.32 / 226.81 | 6 | 15 |
2 | 7 | 2007.00 | 106 | 12.82 | 1857 | 2524 | 2.85 / 229.33 | 15 | 34 |
3 | 13 | 1510.00 | 36 | 13.65 | 1518 | 746 | 3.59 / 230.08 | 5 | 43 |
4 | 13 | 1204.80 | 36 | 13.78 | 1302 | 646 | 4.24 / 230.73 | 5 | 46 |
5 | 13 | 551.72 | 36 | 14.12 | 799 | 406 | 4.65 / 231.13 | 5 | 50 |
6 | 8 | 0.08 | 450 | 14.25 | 314 | 2014 | 6.66 / 233.14 | 6 | 61 |
Average= | 6.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.20 | 57 | 14.53 | 397 | 329 | 0.33 / 219.93 | 6 | 16 |
2 | 7 | 2010.16 | 106 | 12.86 | 1857 | 2531 | 2.86 / 222.46 | 16 | 34 |
3 | 13 | 1690.08 | 36 | 13.61 | 1652 | 809 | 3.67 / 223.27 | 5 | 42 |
4 | 13 | 1162.92 | 36 | 13.81 | 1275 | 634 | 4.30 / 223.91 | 5 | 47 |
5 | 13 | 524.80 | 36 | 14.15 | 775 | 395 | 4.70 / 224.30 | 5 | 50 |
6 | 13 | 0.80 | 36 | 14.60 | 321 | 169 | 4.87 / 224.47 | 6 | 35 |
7 | 8 | 0.04 | 450 | 14.21 | 315 | 2014 | 6.88 / 226.49 | 6 | 68 |
Average= | 6.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.04 | 57 | 14.52 | 406 | 336 | 0.34 / 213.09 | 6 | 17 |
2 | 7 | 2011.28 | 106 | 12.88 | 1859 | 2538 | 2.87 / 215.63 | 17 | 35 |
3 | 13 | 1916.60 | 36 | 13.44 | 1803 | 872 | 3.75 / 216.50 | 5 | 39 |
4 | 13 | 1119.68 | 36 | 13.84 | 1232 | 614 | 4.36 / 217.11 | 5 | 48 |
5 | 13 | 688.72 | 36 | 14.05 | 917 | 464 | 4.82 / 217.58 | 5 | 50 |
6 | 8 | 0.00 | 450 | 14.25 | 316 | 2026 | 6.85 / 219.60 | 6 | 59 |
Average= | 6.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.72 | 57 | 14.53 | 401 | 332 | 0.33 / 206.35 | 6 | 19 |
2 | 7 | 2004.48 | 105 | 12.90 | 1855 | 2513 | 2.84 / 208.86 | 19 | 37 |
3 | 13 | 1694.08 | 36 | 13.62 | 1658 | 813 | 3.66 / 209.68 | 5 | 45 |
4 | 13 | 1147.84 | 36 | 13.83 | 1271 | 633 | 4.29 / 210.31 | 5 | 50 |
5 | 13 | 510.16 | 36 | 14.18 | 767 | 392 | 4.68 / 210.70 | 5 | 52 |
6 | 8 | 0.00 | 450 | 14.25 | 320 | 2052 | 6.73 / 212.75 | 6 | 71 |
Average= | 6.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.24 | 57 | 14.54 | 393 | 326 | 0.33 / 199.45 | 6 | 18 |
2 | 7 | 2003.52 | 105 | 12.93 | 1853 | 2516 | 2.84 / 201.97 | 18 | 36 |
3 | 13 | 1593.16 | 36 | 13.67 | 1588 | 781 | 3.62 / 202.75 | 5 | 44 |
4 | 13 | 1181.92 | 36 | 13.83 | 1293 | 644 | 4.27 / 203.39 | 5 | 49 |
5 | 13 | 521.04 | 36 | 14.17 | 775 | 395 | 4.66 / 203.79 | 5 | 53 |
6 | 13 | 14.96 | 36 | 14.57 | 342 | 179 | 4.84 / 203.97 | 5 | 45 |
7 | 8 | -0.08 | 450 | 14.21 | 321 | 2053 | 6.89 / 206.02 | 6 | 70 |
Average= | 6.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.16 | 57 | 14.53 | 399 | 330 | 0.33 / 192.72 | 6 | 19 |
2 | 7 | 2004.44 | 106 | 12.95 | 1858 | 2550 | 2.88 / 195.27 | 19 | 38 |
3 | 13 | 1695.12 | 36 | 13.64 | 1661 | 816 | 3.70 / 196.09 | 5 | 44 |
4 | 13 | 1148.56 | 36 | 13.85 | 1270 | 633 | 4.33 / 196.72 | 5 | 51 |
5 | 13 | 401.92 | 36 | 14.27 | 676 | 347 | 4.68 / 197.07 | 5 | 50 |
6 | 8 | 0.16 | 450 | 14.25 | 321 | 2058 | 6.74 / 199.13 | 6 | 70 |
Average= | 6.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.36 | 57 | 14.54 | 402 | 333 | 0.33 / 185.99 | 6 | 18 |
2 | 7 | 2006.52 | 106 | 12.97 | 1858 | 2554 | 2.89 / 188.54 | 18 | 38 |
3 | 13 | 1697.12 | 36 | 13.65 | 1649 | 810 | 3.70 / 189.35 | 5 | 44 |
4 | 13 | 1058.80 | 36 | 13.90 | 1195 | 598 | 4.30 / 189.95 | 5 | 51 |
5 | 13 | 532.44 | 36 | 14.19 | 782 | 399 | 4.70 / 190.35 | 5 | 52 |
6 | 8 | 0.00 | 450 | 14.26 | 318 | 2041 | 6.74 / 192.39 | 6 | 66 |
Average= | 6.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.08 | 57 | 14.53 | 396 | 328 | 0.33 / 179.21 | 6 | 18 |
2 | 7 | 2012.24 | 105 | 12.98 | 1859 | 2534 | 2.86 / 181.74 | 18 | 38 |
3 | 13 | 1812.92 | 36 | 13.60 | 1724 | 844 | 3.71 / 182.59 | 5 | 43 |
4 | 13 | 1151.40 | 36 | 13.86 | 1271 | 634 | 4.34 / 183.22 | 5 | 51 |
5 | 13 | 508.24 | 36 | 14.21 | 765 | 391 | 4.73 / 183.61 | 5 | 52 |
6 | 8 | 0.20 | 450 | 14.27 | 318 | 2042 | 6.77 / 185.65 | 6 | 64 |
Average= | 6.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.60 | 57 | 14.54 | 400 | 332 | 0.33 / 172.48 | 6 | 19 |
2 | 7 | 2003.44 | 106 | 13.01 | 1856 | 2560 | 2.89 / 175.03 | 19 | 38 |
3 | 13 | 1795.28 | 36 | 13.61 | 1715 | 840 | 3.73 / 175.87 | 5 | 43 |
4 | 13 | 1017.52 | 36 | 13.92 | 1169 | 586 | 4.32 / 176.46 | 5 | 52 |
5 | 13 | 486.88 | 36 | 14.22 | 748 | 383 | 4.70 / 176.84 | 5 | 52 |
6 | 8 | 0.04 | 450 | 14.28 | 317 | 2037 | 6.74 / 178.88 | 6 | 64 |
Average= | 6.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.76 | 56 | 14.55 | 396 | 323 | 0.32 / 165.71 | 6 | 18 |
2 | 3 | 1014.40 | 1 | 14.54 | 1190 | 17 | 0.34 / 165.72 | 5 | 17 |
3 | 7 | 2003.28 | 106 | 13.03 | 1854 | 2561 | 2.90 / 168.29 | 17 | 38 |
4 | 13 | 1691.92 | 36 | 13.66 | 1650 | 811 | 3.71 / 169.10 | 5 | 44 |
5 | 13 | 1158.20 | 36 | 13.87 | 1273 | 636 | 4.35 / 169.73 | 5 | 50 |
6 | 13 | 501.04 | 36 | 14.23 | 753 | 386 | 4.73 / 170.12 | 5 | 52 |
7 | 8 | -0.04 | 450 | 14.29 | 315 | 2026 | 6.76 / 172.14 | 6 | 59 |
Average= | 6.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.96 | 55 | 14.55 | 405 | 324 | 0.32 / 158.86 | 6 | 17 |
2 | 3 | 1019.08 | 1 | 14.58 | 1190 | 17 | 0.34 / 158.88 | 5 | 24 |
3 | 7 | 2004.84 | 105 | 13.05 | 1865 | 2556 | 2.90 / 161.44 | 24 | 38 |
4 | 13 | 1685.52 | 36 | 13.67 | 1649 | 812 | 3.71 / 162.25 | 5 | 44 |
5 | 13 | 1050.40 | 36 | 13.92 | 1188 | 595 | 4.30 / 162.84 | 5 | 51 |
6 | 13 | 423.84 | 36 | 14.30 | 683 | 352 | 4.66 / 163.19 | 5 | 48 |
7 | 13 | 5.36 | 36 | 14.64 | 327 | 172 | 4.83 / 163.37 | 6 | 37 |
8 | 8 | 0.24 | 450 | 14.28 | 314 | 2018 | 6.85 / 165.38 | 6 | 70 |
Average= | 6.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.04 | 55 | 14.55 | 396 | 317 | 0.32 / 152.11 | 6 | 18 |
2 | 7 | 2004.28 | 105 | 13.07 | 1862 | 2555 | 2.87 / 154.67 | 18 | 38 |
3 | 13 | 1599.68 | 36 | 13.70 | 1594 | 786 | 3.66 / 155.45 | 5 | 47 |
4 | 13 | 1087.24 | 36 | 13.91 | 1225 | 613 | 4.27 / 156.06 | 5 | 52 |
5 | 13 | 561.76 | 36 | 14.19 | 815 | 416 | 4.69 / 156.48 | 5 | 52 |
6 | 8 | -0.12 | 450 | 14.29 | 320 | 2058 | 6.75 / 158.54 | 6 | 63 |
Average= | 6.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.24 | 58 | 14.54 | 394 | 332 | 0.33 / 145.36 | 6 | 16 |
2 | 3 | 964.12 | -1 | 14.54 | 394 | 0 | 0.00 / 145.36 | 6 | 16 |
3 | 7 | 2006.40 | 106 | 13.10 | 1862 | 2586 | 2.92 / 147.94 | 16 | 38 |
4 | 13 | 1597.20 | 36 | 13.72 | 1591 | 786 | 3.70 / 148.73 | 5 | 47 |
5 | 13 | 1062.52 | 36 | 13.93 | 1207 | 605 | 4.31 / 149.33 | 5 | 52 |
6 | 13 | 514.88 | 36 | 14.23 | 772 | 395 | 4.70 / 149.73 | 5 | 52 |
7 | 8 | 0.32 | 450 | 14.28 | 321 | 2063 | 6.77 / 151.79 | 6 | 61 |
Average= | 6.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.44 | 58 | 14.54 | 401 | 338 | 0.34 / 138.53 | 6 | 16 |
2 | 7 | 2006.24 | 106 | 13.12 | 1864 | 2592 | 2.93 / 141.13 | 16 | 39 |
3 | 13 | 1589.88 | 36 | 13.73 | 1583 | 782 | 3.71 / 141.91 | 5 | 46 |
4 | 13 | 1273.56 | 36 | 13.86 | 1358 | 678 | 4.39 / 142.59 | 5 | 49 |
5 | 13 | 497.48 | 36 | 14.23 | 763 | 391 | 4.78 / 142.98 | 5 | 52 |
6 | 8 | 0.08 | 450 | 14.28 | 319 | 2050 | 6.83 / 145.03 | 6 | 60 |
Average= | 6.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.20 | 58 | 14.56 | 400 | 338 | 0.34 / 131.69 | 6 | 13 |
2 | 7 | 2003.32 | 105 | 13.15 | 1861 | 2570 | 2.91 / 134.26 | 13 | 35 |
3 | 13 | 1697.44 | 36 | 13.70 | 1661 | 819 | 3.73 / 135.08 | 5 | 42 |
4 | 13 | 1149.48 | 36 | 13.91 | 1271 | 636 | 4.36 / 135.71 | 5 | 49 |
5 | 13 | 603.16 | 36 | 14.18 | 854 | 436 | 4.80 / 136.15 | 5 | 54 |
6 | 8 | 0.04 | 450 | 14.30 | 318 | 2046 | 6.85 / 138.19 | 6 | 66 |
Average= | 6.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.04 | 58 | 14.58 | 386 | 326 | 0.33 / 124.86 | 6 | 15 |
2 | 7 | 2004.48 | 105 | 13.18 | 1860 | 2574 | 2.90 / 127.44 | 15 | 39 |
3 | 13 | 1798.72 | 36 | 13.66 | 1733 | 852 | 3.75 / 128.29 | 5 | 45 |
4 | 13 | 1151.76 | 36 | 13.92 | 1262 | 632 | 4.39 / 128.92 | 5 | 50 |
5 | 13 | 496.40 | 36 | 14.26 | 755 | 388 | 4.77 / 129.31 | 5 | 52 |
6 | 8 | 0.04 | 450 | 14.30 | 317 | 2040 | 6.81 / 131.35 | 6 | 59 |
Average= | 6.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.20 | 58 | 14.57 | 392 | 331 | 0.33 / 118.11 | 6 | 17 |
2 | 7 | 2008.68 | 106 | 13.19 | 1864 | 2606 | 2.94 / 120.72 | 17 | 39 |
3 | 13 | 1592.40 | 36 | 13.76 | 1586 | 786 | 3.72 / 121.51 | 5 | 45 |
4 | 13 | 1172.84 | 36 | 13.92 | 1289 | 646 | 4.37 / 122.15 | 5 | 51 |
5 | 13 | 392.68 | 36 | 14.34 | 666 | 344 | 4.71 / 122.50 | 5 | 50 |
6 | 8 | 0.04 | 450 | 14.31 | 317 | 2041 | 6.75 / 124.54 | 6 | 67 |
Average= | 6.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.04 | 58 | 14.62 | 385 | 326 | 0.33 / 111.36 | 6 | 13 |
2 | 7 | 2007.44 | 105 | 13.22 | 1866 | 2590 | 2.92 / 113.95 | 13 | 39 |
3 | 13 | 1708.52 | 36 | 13.72 | 1671 | 825 | 3.74 / 114.77 | 5 | 46 |
4 | 13 | 1162.68 | 36 | 13.93 | 1277 | 640 | 4.38 / 115.41 | 5 | 50 |
5 | 13 | 404.00 | 36 | 14.35 | 668 | 345 | 4.73 / 115.76 | 5 | 51 |
6 | 8 | 0.32 | 450 | 14.32 | 314 | 2023 | 6.75 / 117.78 | 6 | 62 |
Average= | 6.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.40 | 58 | 14.63 | 384 | 326 | 0.33 / 104.34 | 6 | 13 |
2 | 3 | 1011.04 | 1 | 14.59 | 1190 | 17 | 0.34 / 104.35 | 5 | 8 |
3 | 7 | 2008.40 | 105 | 13.24 | 1866 | 2594 | 2.94 / 106.95 | 8 | 40 |
4 | 13 | 1607.52 | 36 | 13.77 | 1599 | 793 | 3.73 / 107.74 | 5 | 46 |
5 | 13 | 1280.04 | 36 | 13.89 | 1367 | 684 | 4.41 / 108.42 | 5 | 49 |
6 | 13 | 504.64 | 36 | 14.27 | 760 | 390 | 4.80 / 108.81 | 5 | 51 |
7 | 13 | 14.12 | 36 | 14.69 | 335 | 177 | 4.98 / 108.99 | 6 | 42 |
8 | 8 | -0.28 | 450 | 14.30 | 317 | 2040 | 7.02 / 111.03 | 6 | 68 |
Average= | 6.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.44 | 61 | 14.62 | 387 | 345 | 0.35 / 97.48 | 6 | 13 |
2 | 3 | 966.72 | -1 | 14.62 | 387 | 0 | 0.00 / 97.48 | 6 | 13 |
3 | 7 | 2013.08 | 105 | 13.25 | 1870 | 2602 | 2.95 / 100.08 | 13 | 40 |
4 | 13 | 1814.60 | 36 | 13.69 | 1741 | 858 | 3.80 / 100.94 | 5 | 43 |
5 | 13 | 1050.56 | 36 | 13.99 | 1191 | 600 | 4.40 / 101.54 | 5 | 51 |
6 | 13 | 627.28 | 36 | 14.20 | 865 | 442 | 4.85 / 101.98 | 5 | 53 |
7 | 8 | -0.08 | 450 | 14.35 | 314 | 2028 | 6.87 / 104.01 | 6 | 67 |
Average= | 6.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.60 | 61 | 14.65 | 381 | 340 | 0.34 / 90.56 | 6 | 10 |
2 | 7 | 2003.36 | 106 | 13.27 | 1861 | 2618 | 2.96 / 93.18 | 10 | 36 |
3 | 13 | 1576.08 | 36 | 13.79 | 1570 | 779 | 3.74 / 93.96 | 5 | 43 |
4 | 13 | 1143.36 | 36 | 13.96 | 1260 | 633 | 4.37 / 94.59 | 5 | 50 |
5 | 13 | 389.56 | 36 | 14.38 | 659 | 341 | 4.71 / 94.93 | 5 | 49 |
6 | 13 | 15.88 | 36 | 14.71 | 334 | 177 | 4.89 / 95.11 | 6 | 42 |
7 | 8 | -0.08 | 450 | 14.31 | 315 | 2028 | 6.92 / 97.14 | 6 | 73 |
Average= | 6.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.08 | 61 | 14.67 | 375 | 336 | 0.34 / 83.75 | 6 | 10 |
2 | 7 | 2004.64 | 106 | 13.29 | 1866 | 2629 | 2.96 / 86.38 | 10 | 39 |
3 | 13 | 1802.72 | 36 | 13.72 | 1731 | 855 | 3.82 / 87.23 | 5 | 42 |
4 | 13 | 1124.72 | 36 | 13.96 | 1255 | 631 | 4.45 / 87.86 | 5 | 49 |
5 | 13 | 394.76 | 36 | 14.38 | 666 | 345 | 4.79 / 88.21 | 5 | 50 |
6 | 8 | 0.00 | 450 | 14.37 | 311 | 2011 | 6.81 / 90.22 | 6 | 60 |
Average= | 6.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.08 | 60 | 14.67 | 383 | 337 | 0.34 / 77.02 | 6 | 12 |
2 | 3 | 1016.64 | 1 | 14.68 | 1199 | 18 | 0.35 / 77.03 | 5 | 25 |
3 | 7 | 2007.72 | 105 | 13.30 | 1866 | 2606 | 2.96 / 79.64 | 25 | 40 |
4 | 13 | 1498.72 | 36 | 13.83 | 1509 | 751 | 3.71 / 80.39 | 5 | 47 |
5 | 13 | 1181.32 | 36 | 13.94 | 1284 | 644 | 4.36 / 81.04 | 5 | 51 |
6 | 13 | 415.60 | 36 | 14.36 | 680 | 352 | 4.71 / 81.39 | 5 | 50 |
7 | 8 | -0.16 | 450 | 14.38 | 313 | 2025 | 6.73 / 83.41 | 6 | 62 |
Average= | 5.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.16 | 63 | 14.67 | 384 | 355 | 0.35 / 69.98 | 6 | 10 |
2 | 3 | 965.08 | -1 | 14.67 | 384 | 0 | 0.00 / 69.98 | 6 | 10 |
3 | 7 | 2006.96 | 106 | 13.32 | 1870 | 2640 | 3.00 / 72.62 | 10 | 40 |
4 | 13 | 1800.88 | 36 | 13.74 | 1732 | 857 | 3.85 / 73.47 | 5 | 45 |
5 | 13 | 1110.56 | 36 | 13.97 | 1244 | 626 | 4.48 / 74.10 | 5 | 51 |
6 | 13 | 466.08 | 36 | 14.32 | 728 | 375 | 4.85 / 74.47 | 5 | 52 |
7 | 13 | 23.64 | 36 | 14.72 | 341 | 181 | 5.03 / 74.66 | 6 | 43 |
8 | 8 | 0.00 | 450 | 14.33 | 314 | 2025 | 7.06 / 76.68 | 6 | 68 |
Average= | 5.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.48 | 63 | 14.69 | 378 | 350 | 0.35 / 62.94 | 6 | 9 |
2 | 7 | 2008.88 | 105 | 13.33 | 1871 | 2619 | 2.97 / 65.56 | 9 | 40 |
3 | 13 | 1682.96 | 36 | 13.78 | 1657 | 822 | 3.79 / 66.38 | 5 | 46 |
4 | 13 | 1130.72 | 36 | 13.96 | 1263 | 635 | 4.43 / 67.02 | 5 | 50 |
5 | 13 | 472.12 | 36 | 14.31 | 739 | 381 | 4.81 / 67.40 | 5 | 53 |
6 | 13 | 27.40 | 36 | 14.72 | 349 | 185 | 4.99 / 67.58 | 6 | 44 |
7 | 8 | -0.24 | 450 | 14.33 | 316 | 2038 | 7.03 / 69.62 | 6 | 66 |
Average= | 5.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.12 | 63 | 14.71 | 359 | 333 | 0.33 / 56.04 | 6 | 10 |
2 | 7 | 2014.12 | 105 | 13.34 | 1873 | 2624 | 2.96 / 58.66 | 10 | 37 |
3 | 13 | 1595.76 | 36 | 13.81 | 1592 | 791 | 3.75 / 59.45 | 5 | 43 |
4 | 13 | 981.68 | 36 | 14.02 | 1149 | 580 | 4.33 / 60.03 | 5 | 50 |
5 | 13 | 452.16 | 36 | 14.34 | 720 | 372 | 4.70 / 60.40 | 5 | 51 |
6 | 13 | 23.52 | 36 | 14.74 | 340 | 180 | 4.88 / 60.58 | 6 | 42 |
7 | 8 | -0.32 | 450 | 14.35 | 311 | 2008 | 6.89 / 62.59 | 6 | 67 |
Average= | 5.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.64 | 63 | 14.70 | 360 | 333 | 0.33 / 49.12 | 6 | 9 |
2 | 7 | 2010.40 | 106 | 13.34 | 1867 | 2640 | 2.97 / 51.76 | 9 | 40 |
3 | 13 | 1490.96 | 36 | 13.83 | 1518 | 756 | 3.73 / 52.51 | 5 | 48 |
4 | 13 | 1066.20 | 36 | 13.99 | 1210 | 609 | 4.34 / 53.12 | 5 | 51 |
5 | 13 | 514.16 | 36 | 14.29 | 772 | 397 | 4.74 / 53.52 | 5 | 53 |
6 | 13 | 31.36 | 36 | 14.73 | 341 | 181 | 4.92 / 53.70 | 6 | 44 |
7 | 8 | -0.28 | 450 | 14.33 | 311 | 2005 | 6.92 / 55.70 | 6 | 62 |
Average= | 5.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.40 | 63 | 14.69 | 371 | 343 | 0.34 / 42.17 | 6 | 10 |
2 | 7 | 2004.48 | 105 | 13.34 | 1861 | 2607 | 2.95 / 44.77 | 10 | 40 |
3 | 13 | 1588.84 | 36 | 13.81 | 1587 | 789 | 3.74 / 45.56 | 5 | 47 |
4 | 13 | 1043.76 | 36 | 13.99 | 1192 | 600 | 4.34 / 46.16 | 5 | 50 |
5 | 13 | 605.04 | 36 | 14.22 | 851 | 436 | 4.78 / 46.60 | 5 | 54 |
6 | 13 | 31.36 | 36 | 14.73 | 348 | 185 | 4.96 / 46.78 | 6 | 44 |
7 | 8 | -0.08 | 450 | 14.33 | 310 | 1999 | 6.96 / 48.78 | 6 | 73 |
Average= | 5.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.16 | 63 | 14.73 | 340 | 316 | 0.32 / 35.20 | 6 | 10 |
2 | 7 | 2016.12 | 105 | 13.34 | 1838 | 2574 | 2.89 / 37.77 | 10 | 40 |
3 | 13 | 1595.32 | 36 | 13.80 | 1579 | 784 | 3.67 / 38.56 | 5 | 47 |
4 | 13 | 1166.04 | 36 | 13.94 | 1283 | 644 | 4.32 / 39.20 | 5 | 51 |
5 | 13 | 612.32 | 36 | 14.21 | 854 | 437 | 4.76 / 39.64 | 5 | 52 |
6 | 13 | 15.64 | 36 | 14.75 | 334 | 177 | 4.93 / 39.82 | 6 | 43 |
7 | 8 | -0.20 | 450 | 14.31 | 312 | 2009 | 6.94 / 41.82 | 6 | 67 |
Average= | 5.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.84 | 63 | 14.71 | 340 | 315 | 0.32 / 28.82 | 6 | 10 |
2 | 3 | 1016.64 | 1 | 14.71 | 1174 | 17 | 0.33 / 28.84 | 5 | 27 |
3 | 7 | 2004.28 | 105 | 13.34 | 1821 | 2551 | 2.88 / 31.39 | 27 | 40 |
4 | 13 | 1594.40 | 36 | 13.81 | 1544 | 768 | 3.65 / 32.16 | 5 | 47 |
5 | 13 | 1161.48 | 36 | 13.97 | 1228 | 618 | 4.27 / 32.77 | 5 | 52 |
6 | 13 | 182.56 | 36 | 14.63 | 430 | 226 | 4.49 / 33.00 | 5 | 42 |
7 | 13 | 5.56 | 36 | 14.79 | 278 | 148 | 4.64 / 33.15 | 6 | 38 |
8 | 8 | -0.16 | 450 | 14.38 | 268 | 1734 | 6.38 / 34.88 | 6 | 77 |
Average= | 4.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.92 | 38 | 14.83 | 340 | 192 | 0.19 / 22.08 | 6 | 8 |
2 | 10 | 1040.36 | 11 | 14.67 | 1125 | 182 | 0.37 / 22.26 | 5 | 27 |
3 | 10 | 1083.16 | 8 | 14.57 | 1168 | 136 | 0.51 / 22.40 | 5 | 30 |
4 | 3 | 1104.36 | 5 | 14.71 | 1208 | 89 | 0.60 / 22.49 | 5 | 43 |
5 | 7 | 2007.64 | 105 | 13.31 | 1816 | 2538 | 3.14 / 25.02 | 43 | 39 |
6 | 13 | 1598.88 | 36 | 13.80 | 1544 | 767 | 3.90 / 25.79 | 5 | 47 |
7 | 13 | 982.40 | 36 | 14.01 | 1097 | 553 | 4.46 / 26.34 | 5 | 53 |
8 | 13 | 339.88 | 36 | 14.46 | 565 | 294 | 4.75 / 26.64 | 5 | 48 |
9 | 13 | 20.56 | 36 | 14.76 | 292 | 155 | 4.91 / 26.79 | 6 | 43 |
10 | 8 | -0.12 | 450 | 14.36 | 265 | 1712 | 6.62 / 28.51 | 6 | 69 |
Average= | 4.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.60 | 63 | 14.66 | 342 | 316 | 0.32 / 17.25 | 6 | 12 |
2 | 7 | 1333.12 | 105 | 13.61 | 1332 | 1903 | 2.22 / 19.15 | 12 | 43 |
3 | 13 | 1132.36 | 36 | 13.96 | 1203 | 605 | 2.82 / 19.75 | 5 | 48 |
4 | 13 | 287.12 | 36 | 14.50 | 520 | 271 | 3.10 / 20.03 | 5 | 47 |
5 | 13 | 17.00 | 36 | 14.76 | 288 | 153 | 3.25 / 20.18 | 6 | 40 |
6 | 8 | -0.16 | 450 | 14.33 | 265 | 1709 | 4.96 / 21.89 | 6 | 70 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.20 | 63 | 14.65 | 340 | 314 | 0.31 / 12.43 | 6 | 12 |
2 | 7 | 1330.56 | 106 | 13.59 | 1330 | 1916 | 2.23 / 14.34 | 12 | 43 |
3 | 13 | 1024.84 | 36 | 14.01 | 1126 | 568 | 2.80 / 14.91 | 5 | 49 |
4 | 13 | 394.80 | 36 | 14.37 | 611 | 316 | 3.11 / 15.23 | 5 | 51 |
5 | 8 | -0.08 | 450 | 14.35 | 264 | 1705 | 4.82 / 16.93 | 6 | 67 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.24 | 38 | 14.75 | 334 | 187 | 0.19 / 6.47 | 6 | 10 |
2 | 10 | 1046.68 | 11 | 14.58 | 1140 | 183 | 0.37 / 6.66 | 5 | 26 |
3 | 10 | 1087.76 | 8 | 14.51 | 1168 | 136 | 0.51 / 6.79 | 5 | 29 |
4 | 3 | 1134.52 | 7 | 14.61 | 1223 | 125 | 0.63 / 6.92 | 5 | 42 |
5 | 7 | 1519.32 | 105 | 13.45 | 1466 | 2070 | 2.70 / 8.99 | 42 | 38 |
6 | 13 | 1423.12 | 36 | 13.75 | 1404 | 695 | 3.40 / 9.68 | 5 | 41 |
7 | 13 | 888.76 | 36 | 14.01 | 1021 | 515 | 3.91 / 10.20 | 5 | 49 |
8 | 13 | 231.48 | 36 | 14.51 | 463 | 242 | 4.15 / 10.44 | 5 | 44 |
9 | 8 | -0.04 | 450 | 14.34 | 259 | 1671 | 5.82 / 12.11 | 6 | 78 |
Average= | 4.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.64 | 38 | 14.77 | 314 | 176 | 0.18 / 2.42 | 6 | 8 |
2 | 10 | 1052.16 | 12 | 14.38 | 1129 | 195 | 0.37 / 2.61 | 5 | 25 |
3 | 10 | 1091.32 | 7 | 14.34 | 1169 | 117 | 0.49 / 2.73 | 5 | 27 |
4 | 3 | 1115.52 | 6 | 14.33 | 1196 | 103 | 0.59 / 2.83 | 5 | 30 |
5 | 7 | 1059.08 | 106 | 13.57 | 1130 | 1625 | 2.22 / 4.46 | 30 | 41 |
6 | 13 | 65.76 | 36 | 14.61 | 320 | 168 | 2.38 / 4.63 | 6 | 40 |
7 | 8 | -0.08 | 450 | 14.30 | 258 | 1660 | 4.05 / 6.29 | 6 | 62 |
Average= | 3.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.56 | 38 | 14.50 | 313 | 172 | 0.17 / 0.17 | 6 | 9 |
2 | 7 | 124.72 | 105 | 14.36 | 318 | 479 | 0.65 / 0.65 | 9 | 11 |
3 | 13 | 81.04 | 36 | 14.69 | 291 | 154 | 0.81 / 0.81 | 6 | 14 |
4 | 8 | 0.16 | 450 | 14.51 | 220 | 1436 | 2.24 / 2.24 | 6 | 45 |
Average= | 2.24 (KJ/cycle) |