SIO Argo Site:
Pump Diagnostics Page   



Serial= 8865 WMO= 1902053

Return

←PreviousNext→

Cycle 163 GMT 11/12/2024 23:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.80 31 14.85 464 214 0.21 / 692.59 2 3
2 12 1176.24 3 15.03 2108 95 0.31 / 692.68 2 2
3 7 2010.12 33 14.60 3134 1510 1.82 / 694.19 2 4
4 13 1664.88 25 14.58 2679 976 2.80 / 695.17 2 3
5 13 794.36 25 14.74 1486 548 3.34 / 695.72 2 3
6 13 122.00 25 14.90 497 185 3.53 / 695.90 2 3
7 13 36.44 25 14.92 356 133 3.66 / 696.04 2 2
8 8 0.12 175 14.89 291 758 4.42 / 696.79 2 6
Average= 4.25
(KJ/cycle)

Cycle 162 GMT 2/12/2024 4:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.84 31 14.84 478 220 0.22 / 688.19 3 3
2 12 1169.12 3 15.04 2077 94 0.31 / 688.29 2 3
3 7 2008.04 33 14.61 3137 1512 1.83 / 689.80 2 3
4 13 1516.16 25 14.61 2487 908 2.73 / 690.71 2 3
5 13 854.16 25 14.71 1571 578 3.31 / 691.29 2 3
6 13 146.72 25 14.90 532 198 3.51 / 691.48 2 3
7 13 41.68 25 14.91 361 135 3.64 / 691.62 2 3
8 8 0.08 175 14.89 290 756 4.40 / 692.37 2 4
Average= 4.25
(KJ/cycle)

Cycle 161 GMT 22/11/2024 9:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.04 31 14.84 469 216 0.22 / 683.84 2 3
2 12 1173.36 3 15.05 2079 94 0.31 / 683.94 2 3
3 7 2004.16 33 14.60 3130 1508 1.82 / 685.45 2 3
4 13 1563.16 25 14.61 2547 930 2.75 / 686.38 2 3
5 13 633.44 25 14.77 1272 470 3.22 / 686.85 2 3
6 13 151.36 25 14.90 558 208 3.43 / 687.05 2 3
7 13 38.92 25 14.91 374 139 3.56 / 687.19 2 4
8 8 -0.04 175 14.88 300 781 4.35 / 687.97 2 4
Average= 4.25
(KJ/cycle)

Cycle 160 GMT 12/11/2024 14:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.40 31 14.85 448 206 0.21 / 679.46 2 3
2 12 1164.16 3 15.05 2076 94 0.30 / 679.55 2 3
3 7 2010.48 33 14.59 3134 1509 1.81 / 681.06 2 3
4 13 1576.32 25 14.60 2567 937 2.75 / 682.00 2 3
5 13 780.60 25 14.75 1473 543 3.29 / 682.54 2 3
6 13 118.84 25 14.90 490 183 3.47 / 682.73 2 3
7 13 66.12 25 14.92 401 150 3.62 / 682.88 2 3
8 8 0.00 175 14.89 289 753 4.37 / 683.63 2 7
Average= 4.25
(KJ/cycle)

Cycle 159 GMT 2/11/2024 19:15:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.20 31 14.85 464 214 0.21 / 675.08 2 3
2 12 1183.72 3 15.04 2110 95 0.31 / 675.18 2 3
3 7 2005.32 34 14.59 3123 1549 1.86 / 676.73 2 3
4 13 1575.60 25 14.60 2562 935 2.79 / 677.66 2 3
5 13 723.16 25 14.76 1384 511 3.30 / 678.17 2 3
6 13 130.60 25 14.91 512 191 3.49 / 678.37 2 3
7 13 42.08 25 14.91 362 135 3.63 / 678.50 2 2
8 8 -0.04 175 14.90 289 754 4.38 / 679.25 2 6
Average= 4.25
(KJ/cycle)

Cycle 158 GMT 24/10/2024 0: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.08 31 14.85 464 214 0.21 / 670.75 2 3
2 12 1177.24 3 15.05 2081 94 0.31 / 670.85 2 3
3 7 2008.16 33 14.58 3124 1503 1.81 / 672.35 2 3
4 13 1561.52 25 14.60 2545 929 2.74 / 673.28 2 4
5 13 782.12 25 14.73 1465 539 3.28 / 673.82 2 4
6 13 100.28 25 14.92 461 172 3.45 / 673.99 2 3
7 13 28.28 25 14.92 339 126 3.58 / 674.12 2 4
8 8 -0.08 175 14.89 289 753 4.33 / 674.87 2 6
Average= 4.24
(KJ/cycle)

Cycle 157 GMT 14/10/2024 4:48:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.88 31 14.87 467 215 0.22 / 666.65 2 3
2 12 1188.88 3 15.03 2122 96 0.31 / 666.75 2 2
3 7 1903.40 33 14.61 3001 1447 1.76 / 668.20 2 3
4 13 1484.76 25 14.63 2445 894 2.65 / 669.09 2 3
5 13 733.92 25 14.77 1404 518 3.17 / 669.61 2 3
6 13 89.60 25 14.92 450 168 3.34 / 669.78 2 3
7 8 0.08 175 14.91 293 765 4.10 / 670.54 2 5
Average= 4.24
(KJ/cycle)

Cycle 156 GMT 4/10/2024 6:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.12 30 14.86 469 209 0.21 / 662.39 2 3
2 12 1187.60 3 15.05 2119 96 0.30 / 662.49 2 2
3 7 2005.20 33 14.62 3140 1515 1.82 / 664.00 2 3
4 13 1507.48 25 14.63 2473 904 2.72 / 664.91 2 3
5 13 832.32 25 14.74 1545 569 3.29 / 665.48 2 5
6 13 122.92 25 14.93 500 187 3.48 / 665.66 2 3
7 8 0.04 175 14.92 296 773 4.25 / 666.44 2 3
Average= 4.24
(KJ/cycle)

Cycle 155 GMT 24/ 9/2024 11:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.40 30 14.86 470 210 0.21 / 658.05 2 3
2 12 1185.08 3 15.04 2106 95 0.30 / 658.15 2 3
3 7 2002.44 33 14.61 3126 1507 1.81 / 659.66 2 3
4 13 1572.44 25 14.61 2560 935 2.75 / 660.59 2 3
5 13 716.96 25 14.77 1380 510 3.26 / 661.10 2 3
6 13 120.20 25 14.93 498 186 3.44 / 661.29 2 3
7 13 24.28 25 14.94 336 125 3.57 / 661.41 2 2
8 8 0.00 175 14.91 296 772 4.34 / 662.18 2 4
Average= 4.24
(KJ/cycle)

Cycle 154 GMT 14/ 9/2024 16:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.44 30 14.87 477 213 0.21 / 653.67 2 3
2 12 1184.04 3 15.04 2110 95 0.31 / 653.77 2 3
3 7 2007.32 33 14.60 3129 1508 1.82 / 655.28 2 3
4 13 1576.24 25 14.60 2565 936 2.75 / 656.21 2 3
5 13 790.28 25 14.75 1491 550 3.30 / 656.76 2 3
6 13 101.40 25 14.93 464 173 3.47 / 656.94 2 4
7 13 29.80 25 14.93 346 129 3.60 / 657.06 2 2
8 8 0.00 175 14.90 299 780 4.38 / 657.84 2 6
Average= 4.24
(KJ/cycle)

Cycle 153 GMT 4/ 9/2024 21:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.32 30 14.86 469 209 0.21 / 649.34 2 3
2 12 1184.76 3 15.06 2106 95 0.30 / 649.44 2 3
3 7 2012.60 34 14.60 3154 1566 1.87 / 651.00 2 3
4 13 1501.88 25 14.61 2468 901 2.77 / 651.90 2 4
5 13 660.84 25 14.78 1299 480 3.25 / 652.38 2 3
6 13 95.12 25 14.93 461 172 3.42 / 652.56 2 3
7 8 0.20 175 14.91 303 791 4.21 / 653.35 2 2
8 14 0.20 25 14.90 304 113 4.33 / 653.46 2 3
Average= 4.24
(KJ/cycle)

Cycle 152 GMT 26/ 8/2024 2:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.80 30 14.87 465 207 0.21 / 645.06 2 3
2 12 1181.20 3 15.04 2120 96 0.30 / 645.15 2 3
3 7 2004.88 33 14.61 3133 1511 1.81 / 646.66 2 3
4 13 1491.28 25 14.63 2451 896 2.71 / 647.56 2 3
5 13 745.52 25 14.76 1416 523 3.23 / 648.08 2 3
6 13 100.72 25 14.93 461 172 3.40 / 648.25 2 3
7 13 23.84 25 14.94 331 124 3.53 / 648.38 2 2
8 8 0.04 175 14.91 290 757 4.28 / 649.13 2 5
Average= 4.24
(KJ/cycle)

Cycle 151 GMT 16/ 8/2024 7: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.56 30 14.86 472 210 0.21 / 640.88 2 3
2 12 1188.68 3 15.04 2131 96 0.31 / 640.98 2 2
3 7 2008.20 33 14.60 3140 1513 1.82 / 642.49 2 4
4 13 1486.24 25 14.62 2450 895 2.71 / 643.38 2 4
5 13 716.40 25 14.78 1379 510 3.22 / 643.89 2 3
6 13 129.80 25 14.93 507 189 3.41 / 644.08 2 3
7 8 0.12 175 14.92 293 765 4.18 / 644.85 2 5
Average= 4.24
(KJ/cycle)

Cycle 150 GMT 6/ 8/2024 11:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.68 30 14.87 466 208 0.21 / 636.61 2 3
2 12 1173.80 3 15.04 2088 94 0.30 / 636.70 2 3
3 7 2012.32 33 14.61 3133 1511 1.81 / 638.21 2 3
4 13 1518.64 25 14.60 2486 907 2.72 / 639.12 2 3
5 13 669.76 25 14.78 1306 483 3.20 / 639.60 2 3
6 13 108.12 25 14.92 476 178 3.38 / 639.78 2 3
7 13 24.20 25 14.93 334 125 3.50 / 639.91 2 3
8 8 -0.08 175 14.90 293 764 4.27 / 640.67 2 6
Average= 4.24
(KJ/cycle)

Cycle 149 GMT 27/ 7/2024 16:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.60 30 14.87 475 212 0.21 / 632.23 2 3
2 12 1187.16 3 15.05 2125 96 0.31 / 632.33 2 3
3 7 2011.20 33 14.60 3139 1512 1.82 / 633.84 2 3
4 13 1578.96 25 14.61 2572 939 2.76 / 634.78 2 3
5 13 713.08 25 14.78 1381 510 3.27 / 635.29 2 3
6 13 113.60 25 14.94 491 183 3.45 / 635.47 2 3
7 13 26.40 25 14.96 344 129 3.58 / 635.60 2 2
8 8 0.00 175 14.92 306 799 4.38 / 636.40 2 6
Average= 4.24
(KJ/cycle)

Cycle 148 GMT 17/ 7/2024 21:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.20 30 14.86 469 209 0.21 / 627.85 2 3
2 12 1163.68 3 15.06 2071 94 0.30 / 627.94 2 3
3 7 2003.08 33 14.61 3142 1515 1.82 / 629.46 2 3
4 13 1648.32 25 14.60 2674 976 2.79 / 630.43 2 3
5 13 705.36 25 14.79 1362 504 3.30 / 630.93 2 3
6 13 121.84 25 14.93 493 184 3.48 / 631.12 2 3
7 13 30.48 25 14.94 344 128 3.61 / 631.25 2 3
8 8 0.16 175 14.92 296 773 4.38 / 632.02 2 11
Average= 4.24
(KJ/cycle)

Cycle 147 GMT 8/ 7/2024 2: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.60 30 14.86 463 206 0.21 / 623.47 2 3
2 12 1174.84 3 15.04 2076 94 0.30 / 623.57 2 3
3 7 2010.52 33 14.60 3127 1507 1.81 / 625.07 2 4
4 13 1657.92 25 14.59 2668 973 2.78 / 626.05 2 4
5 13 709.56 25 14.78 1362 503 3.28 / 626.55 2 3
6 13 123.84 25 14.93 503 188 3.47 / 626.74 2 3
7 13 31.88 25 14.95 350 131 3.60 / 626.87 2 4
8 8 0.00 175 14.92 295 770 4.37 / 627.64 2 6
Average= 4.24
(KJ/cycle)

Cycle 146 GMT 28/ 6/2024 6:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.36 30 14.87 467 208 0.21 / 619.17 2 3
2 12 1184.36 3 15.04 2105 95 0.30 / 619.27 2 3
3 7 2003.16 34 14.61 3132 1556 1.86 / 620.82 2 3
4 13 1487.72 25 14.64 2440 893 2.75 / 621.72 2 3
5 13 632.36 25 14.81 1254 464 3.22 / 622.18 2 4
6 13 127.92 25 14.93 509 190 3.41 / 622.37 2 2
7 13 28.40 25 14.94 338 126 3.53 / 622.50 2 3
8 8 -0.04 175 14.91 295 770 4.30 / 623.27 2 9
Average= 4.24
(KJ/cycle)

Cycle 145 GMT 18/ 6/2024 11:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.16 30 14.88 467 208 0.21 / 614.78 2 3
2 12 1193.24 3 15.03 2139 96 0.30 / 614.88 2 2
3 7 2005.56 33 14.60 3145 1515 1.82 / 616.39 2 3
4 13 1575.64 25 14.62 2578 942 2.76 / 617.34 2 3
5 13 800.96 25 14.74 1502 553 3.32 / 617.89 2 3
6 13 102.32 25 14.93 470 175 3.49 / 618.07 2 3
7 13 34.52 25 14.94 352 131 3.62 / 618.20 2 2
8 8 0.00 175 14.91 294 767 4.39 / 618.96 2 5
Average= 4.24
(KJ/cycle)

Cycle 144 GMT 8/ 6/2024 16:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.12 30 14.88 457 204 0.20 / 610.40 2 3
2 12 1179.04 3 15.05 2115 95 0.30 / 610.50 2 3
3 7 2007.08 33 14.61 3133 1511 1.81 / 612.01 2 3
4 13 1636.44 25 14.60 2646 966 2.78 / 612.97 2 3
5 13 749.56 25 14.78 1432 529 3.30 / 613.50 2 3
6 13 100.04 25 14.95 462 173 3.48 / 613.67 2 4
7 13 28.56 25 14.95 343 128 3.61 / 613.80 2 3
8 8 0.16 175 14.93 295 771 4.38 / 614.57 2 3
Average= 4.24
(KJ/cycle)

Cycle 143 GMT 29/ 5/2024 21:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.24 30 14.89 456 204 0.20 / 606.07 2 3
2 12 1174.64 3 15.07 2116 96 0.30 / 606.17 2 3
3 7 2004.84 33 14.60 3133 1509 1.81 / 607.68 2 3
4 13 1501.72 25 14.62 2471 903 2.71 / 608.58 2 3
5 13 734.92 25 14.78 1408 520 3.23 / 609.10 2 3
6 13 84.36 25 14.96 451 169 3.40 / 609.27 2 3
7 13 46.72 25 14.96 382 143 3.54 / 609.41 2 4
8 8 -0.12 175 14.93 301 786 4.33 / 610.20 2 3
Average= 4.24
(KJ/cycle)

Cycle 142 GMT 20/ 5/2024 2:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.52 30 14.88 459 205 0.20 / 601.71 2 3
2 12 1186.88 3 15.05 2127 96 0.30 / 601.81 2 3
3 7 2004.60 33 14.62 3146 1518 1.82 / 603.33 2 3
4 13 1662.72 25 14.59 2684 979 2.80 / 604.31 2 3
5 13 701.92 25 14.80 1359 503 3.30 / 604.81 2 4
6 13 60.12 25 14.98 405 152 3.45 / 604.96 2 3
7 13 26.44 25 14.97 344 129 3.58 / 605.09 2 3
8 8 0.00 175 14.93 298 779 4.36 / 605.87 2 7
Average= 4.24
(KJ/cycle)

Cycle 141 GMT 10/ 5/2024 6:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.60 30 14.88 461 206 0.21 / 597.43 2 3
2 12 1164.56 3 15.05 2081 94 0.30 / 597.53 2 3
3 7 2005.52 33 14.60 3136 1511 1.81 / 599.04 2 3
4 13 1575.24 25 14.61 2575 941 2.75 / 599.98 2 3
5 13 629.08 25 14.80 1257 465 3.22 / 600.44 2 3
6 13 71.48 25 14.95 431 161 3.38 / 600.60 2 3
7 13 23.84 25 14.96 343 128 3.51 / 600.73 2 2
8 8 -0.04 175 14.92 297 775 4.28 / 601.51 2 3
Average= 4.24
(KJ/cycle)

Cycle 140 GMT 30/ 4/2024 11:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.40 30 14.88 465 208 0.21 / 593.04 2 3
2 12 1177.72 3 15.04 2113 95 0.30 / 593.14 2 3
3 7 2008.40 33 14.60 3140 1513 1.82 / 594.65 2 3
4 13 1561.12 25 14.61 2557 934 2.75 / 595.58 2 3
5 13 859.60 25 14.73 1585 584 3.33 / 596.17 2 3
6 13 83.04 25 14.95 439 164 3.50 / 596.33 2 3
7 13 27.28 25 14.96 343 128 3.63 / 596.46 2 2
8 8 -0.04 175 14.93 294 768 4.39 / 597.23 2 4
Average= 4.24
(KJ/cycle)

Cycle 139 GMT 20/ 4/2024 16:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.88 30 14.88 463 207 0.21 / 588.68 2 3
2 12 1183.32 3 15.05 2122 96 0.30 / 588.78 2 3
3 7 2005.36 33 14.59 3139 1511 1.81 / 590.29 2 3
4 13 1546.48 25 14.61 2532 925 2.74 / 591.21 2 3
5 13 750.24 25 14.77 1425 526 3.26 / 591.74 2 3
6 13 124.52 25 14.95 505 189 3.45 / 591.93 2 3
7 13 31.32 25 14.96 348 130 3.58 / 592.06 2 4
8 8 0.00 175 14.93 296 773 4.36 / 592.83 2 9
Average= 4.23
(KJ/cycle)

Cycle 138 GMT 10/ 4/2024 21:26: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.24 30 14.88 472 211 0.21 / 584.30 2 3
2 12 1191.00 3 15.03 2117 95 0.31 / 584.40 2 3
3 7 2003.64 33 14.60 3140 1513 1.82 / 585.91 2 3
4 13 1643.36 25 14.59 2654 968 2.79 / 586.88 2 3
5 13 687.16 25 14.79 1338 495 3.28 / 587.37 2 3
6 13 111.56 25 14.95 487 182 3.46 / 587.55 2 2
7 13 32.20 25 14.96 353 132 3.60 / 587.69 2 2
8 8 -0.08 175 14.92 302 789 4.38 / 588.48 2 5
Average= 4.23
(KJ/cycle)

Cycle 137 GMT 1/ 4/2024 2:10: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.24 30 14.89 467 209 0.21 / 579.98 2 3
2 12 1179.12 3 15.05 2108 95 0.30 / 580.07 2 3
3 7 2012.48 33 14.60 3151 1518 1.82 / 581.59 2 3
4 13 1511.20 25 14.62 2483 908 2.73 / 582.50 2 3
5 13 681.32 25 14.80 1329 492 3.22 / 582.99 2 4
6 13 117.16 25 14.95 495 185 3.41 / 583.17 2 3
7 13 30.80 25 14.95 355 133 3.54 / 583.31 2 3
8 8 0.12 175 14.92 300 783 4.32 / 584.09 2 3
Average= 4.23
(KJ/cycle)

Cycle 136 GMT 22/ 3/2024 6:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.48 30 14.87 466 208 0.21 / 575.64 2 3
2 12 1179.56 3 15.06 2100 95 0.30 / 575.73 2 3
3 7 2008.68 33 14.60 3138 1512 1.81 / 577.25 2 3
4 13 1567.12 25 14.61 2558 934 2.75 / 578.18 2 3
5 13 712.92 25 14.79 1373 508 3.26 / 578.69 2 3
6 13 137.84 25 14.94 521 195 3.45 / 578.88 2 3
7 13 32.24 25 14.96 345 129 3.58 / 579.01 2 2
8 8 0.12 175 14.92 290 757 4.34 / 579.77 2 5
Average= 4.23
(KJ/cycle)

Cycle 135 GMT 12/ 3/2024 11:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.12 30 14.89 468 209 0.21 / 571.22 2 3
2 12 1170.04 3 15.05 2093 94 0.30 / 571.32 2 3
3 7 2005.76 33 14.62 3141 1515 1.82 / 572.83 2 3
4 13 1556.60 25 14.62 2550 932 2.75 / 573.76 2 3
5 13 788.36 25 14.76 1489 549 3.30 / 574.31 2 3
6 13 169.40 25 14.92 579 216 3.52 / 574.53 2 3
7 13 41.52 25 14.95 363 136 3.65 / 574.67 2 3
8 8 0.00 175 14.93 293 766 4.42 / 575.43 2 6
Average= 4.23
(KJ/cycle)

Cycle 134 GMT 2/ 3/2024 16:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.60 30 14.87 469 209 0.21 / 566.89 2 3
2 12 1186.56 3 15.07 2127 96 0.31 / 566.99 2 3
3 7 2006.16 33 14.62 3135 1513 1.82 / 568.50 2 3
4 13 1496.56 25 14.64 2466 903 2.72 / 569.40 2 3
5 13 737.76 25 14.78 1413 522 3.24 / 569.92 2 3
6 13 144.52 25 14.94 533 199 3.44 / 570.12 2 3
7 13 38.60 25 14.95 360 135 3.58 / 570.26 2 3
8 8 0.04 175 14.93 290 758 4.33 / 571.01 2 4
Average= 4.23
(KJ/cycle)

Cycle 133 GMT 21/ 2/2024 21:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.44 30 14.87 480 214 0.21 / 562.53 2 3
2 12 1176.08 3 15.04 2103 95 0.31 / 562.63 2 3
3 7 2006.52 33 14.62 3138 1514 1.82 / 564.14 2 3
4 13 1502.80 25 14.61 2468 901 2.72 / 565.04 2 4
5 13 752.24 25 14.76 1434 529 3.25 / 565.57 2 3
6 13 163.52 25 14.93 562 210 3.46 / 565.78 2 3
7 13 44.60 25 14.94 369 138 3.60 / 565.92 2 3
8 8 -0.04 175 14.92 292 762 4.36 / 566.68 2 6
Average= 4.23
(KJ/cycle)

Cycle 132 GMT 12/ 2/2024 2: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.96 30 14.89 469 210 0.21 / 558.12 2 3
2 12 1168.08 3 15.03 2090 94 0.30 / 558.21 2 3
3 7 2010.16 33 14.62 3138 1514 1.82 / 559.73 2 3
4 13 1581.64 25 14.61 2576 941 2.76 / 560.67 2 3
5 13 745.16 25 14.78 1418 524 3.28 / 561.19 2 4
6 13 165.52 25 14.93 562 210 3.49 / 561.40 2 3
7 13 45.64 25 14.95 368 138 3.63 / 561.54 2 2
8 8 0.12 175 14.92 297 775 4.41 / 562.32 2 5
Average= 4.23
(KJ/cycle)

Cycle 131 GMT 2/ 2/2024 6:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.64 30 14.88 474 212 0.21 / 553.81 2 3
2 12 1173.04 3 15.07 2101 95 0.31 / 553.90 2 3
3 7 2007.08 33 14.60 3131 1509 1.82 / 555.41 2 3
4 13 1481.24 25 14.63 2447 895 2.71 / 556.30 2 2
5 13 721.36 25 14.78 1386 512 3.22 / 556.82 2 3
6 13 134.12 25 14.94 515 192 3.41 / 557.01 2 3
7 13 34.60 25 14.96 352 132 3.55 / 557.14 2 2
8 8 0.08 175 14.93 295 771 4.32 / 557.91 2 12
Average= 4.23
(KJ/cycle)

Cycle 130 GMT 23/ 1/2024 9: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.08 30 14.87 469 209 0.21 / 549.40 2 3
2 12 1160.36 3 15.06 2077 94 0.30 / 549.49 2 3
3 7 2003.88 33 14.61 3135 1511 1.81 / 551.00 2 3
4 13 1554.80 25 14.62 2541 929 2.74 / 551.93 2 3
5 13 792.68 25 14.75 1491 550 3.29 / 552.48 2 3
6 13 164.52 25 14.94 571 213 3.51 / 552.69 2 3
7 13 19.52 25 14.96 332 124 3.63 / 552.82 2 2
8 8 0.04 175 14.94 297 777 4.41 / 553.59 2 5
Average= 4.23
(KJ/cycle)

Cycle 129 GMT 13/ 1/2024 11:39: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.36 30 14.89 471 210 0.21 / 545.05 2 3
2 12 1169.20 3 15.07 2107 95 0.31 / 545.14 2 2
3 7 2003.68 33 14.61 3140 1514 1.82 / 546.65 2 3
4 13 1468.08 25 14.64 2428 889 2.71 / 547.54 2 3
5 13 709.44 25 14.80 1378 510 3.22 / 548.05 2 3
6 13 192.48 25 14.92 613 229 3.45 / 548.28 2 2
7 13 21.84 25 14.95 331 124 3.57 / 548.41 2 4
8 8 0.00 175 14.93 299 781 4.35 / 549.19 2 4
Average= 4.22
(KJ/cycle)

Cycle 128 GMT 3/ 1/2024 14:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.08 30 14.88 478 213 0.21 / 540.74 2 3
2 12 1173.48 3 15.07 2095 95 0.31 / 540.84 2 2
3 7 2004.20 33 14.62 3146 1518 1.83 / 542.36 2 3
4 13 1489.48 25 14.66 2468 905 2.73 / 543.26 2 4
5 13 632.72 25 14.84 1256 466 3.20 / 543.73 2 4
6 13 162.08 25 14.94 559 209 3.41 / 543.94 2 3
7 13 41.32 25 14.97 361 135 3.54 / 544.07 2 2
8 8 0.24 175 14.94 292 763 4.30 / 544.84 2 5
Average= 4.22
(KJ/cycle)

Cycle 127 GMT 24/12/2023 16:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.60 30 14.89 468 209 0.21 / 536.29 2 3
2 12 1180.68 3 15.06 2108 95 0.30 / 536.38 2 3
3 7 2007.24 33 14.62 3146 1518 1.82 / 537.90 2 3
4 13 1581.96 25 14.63 2575 942 2.76 / 538.84 2 3
5 13 799.32 25 14.77 1494 552 3.32 / 539.40 2 3
6 13 189.32 25 14.94 605 226 3.54 / 539.62 2 3
7 13 53.96 25 14.95 385 144 3.69 / 539.77 2 3
8 8 0.08 175 14.93 293 766 4.45 / 540.53 2 7
Average= 4.22
(KJ/cycle)

Cycle 126 GMT 14/12/2023 19: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.80 30 14.88 459 205 0.20 / 531.88 2 3
2 12 1178.88 3 15.07 2123 96 0.30 / 531.97 2 3
3 7 2006.08 33 14.63 3135 1514 1.81 / 533.48 2 3
4 13 1564.76 25 14.64 2552 934 2.75 / 534.42 2 3
5 13 791.48 25 14.79 1486 549 3.30 / 534.97 2 3
6 13 171.16 25 14.94 572 214 3.51 / 535.18 2 3
7 13 44.88 25 14.97 368 138 3.65 / 535.32 2 4
8 8 0.08 175 14.94 291 761 4.41 / 536.08 2 7
Average= 4.22
(KJ/cycle)

Cycle 125 GMT 4/12/2023 21:38:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.08 30 14.91 470 210 0.21 / 527.57 2 3
2 12 1185.88 3 15.08 2114 96 0.31 / 527.67 2 3
3 7 2002.88 33 14.63 3136 1514 1.82 / 529.18 2 3
4 13 1489.00 25 14.66 2455 900 2.72 / 530.08 2 3
5 13 722.12 25 14.82 1383 512 3.23 / 530.59 2 3
6 13 137.08 25 14.96 518 194 3.43 / 530.79 2 2
7 13 30.16 25 14.99 342 128 3.55 / 530.91 2 3
8 8 0.04 175 14.95 289 756 4.31 / 531.67 2 4
Average= 4.22
(KJ/cycle)

Cycle 124 GMT 25/11/2023 0: 6: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.40 30 14.89 465 208 0.21 / 523.40 2 3
2 12 1162.20 3 15.08 2089 95 0.30 / 523.49 2 3
3 7 2005.80 34 14.61 3135 1557 1.86 / 525.05 2 3
4 13 1467.64 25 14.66 2424 888 2.75 / 525.94 2 3
5 13 635.04 25 14.83 1259 467 3.21 / 526.40 2 4
6 13 149.68 25 14.95 534 200 3.41 / 526.60 2 3
7 8 0.00 175 14.95 289 756 4.17 / 527.36 2 5
Average= 4.22
(KJ/cycle)

Cycle 123 GMT 15/11/2023 2:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.00 30 14.90 475 212 0.21 / 519.14 3 3
2 12 1171.52 3 15.10 2110 96 0.31 / 519.24 2 2
3 7 2008.12 33 14.63 3133 1513 1.82 / 520.75 2 3
4 13 1482.36 25 14.66 2436 893 2.71 / 521.64 2 3
5 13 633.24 25 14.84 1257 466 3.18 / 522.11 2 3
6 13 157.36 25 14.96 549 205 3.38 / 522.31 2 3
7 13 16.68 25 14.98 318 119 3.50 / 522.43 2 2
8 8 0.16 175 14.95 290 759 4.26 / 523.19 2 8
Average= 4.22
(KJ/cycle)

Cycle 122 GMT 5/11/2023 4:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.48 30 14.92 466 209 0.21 / 514.71 2 3
2 12 1176.68 3 15.07 2104 95 0.30 / 514.81 2 3
3 7 2003.64 33 14.63 3135 1514 1.82 / 516.32 2 3
4 13 1642.00 25 14.63 2653 970 2.79 / 517.29 2 3
5 13 759.00 25 14.80 1434 531 3.32 / 517.82 2 3
6 13 165.56 25 14.97 562 210 3.53 / 518.03 2 3
7 13 39.48 25 14.98 358 134 3.66 / 518.17 2 4
8 8 0.04 175 14.95 291 761 4.42 / 518.93 2 5
Average= 4.22
(KJ/cycle)

Cycle 121 GMT 26/10/2023 7: 7:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.48 30 14.89 463 207 0.21 / 510.45 2 3
2 12 1170.96 3 15.07 2096 95 0.30 / 510.55 2 3
3 7 2005.84 33 14.62 3129 1510 1.81 / 512.06 2 2
4 13 1557.16 25 14.64 2541 930 2.74 / 512.99 2 3
5 13 766.28 25 14.80 1449 536 3.28 / 513.52 2 3
6 13 160.76 25 14.95 562 210 3.49 / 513.73 2 3
7 8 0.16 175 14.95 295 772 4.26 / 514.50 2 6
Average= 4.22
(KJ/cycle)

Cycle 120 GMT 16/10/2023 9:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.80 30 14.91 474 212 0.21 / 506.13 2 3
2 12 1169.20 3 15.08 2090 95 0.31 / 506.23 2 2
3 7 2006.20 33 14.63 3136 1514 1.82 / 507.74 2 3
4 13 1502.40 25 14.64 2469 904 2.72 / 508.65 2 3
5 13 738.88 25 14.80 1407 521 3.24 / 509.17 2 3
6 13 147.68 25 14.96 537 201 3.45 / 509.37 2 3
7 13 15.16 25 14.98 316 118 3.56 / 509.49 2 4
8 8 -0.12 175 14.95 290 759 4.32 / 510.24 2 4
Average= 4.22
(KJ/cycle)

Cycle 119 GMT 6/10/2023 12: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.64 30 14.91 488 218 0.22 / 501.99 2 3
2 12 1180.28 3 15.07 2136 97 0.31 / 502.08 2 3
3 7 2008.64 33 14.61 3166 1526 1.84 / 503.61 2 2
4 13 1400.72 25 14.67 2357 864 2.71 / 504.48 2 3
5 13 646.36 25 14.83 1291 479 3.18 / 504.95 2 3
6 13 142.68 25 14.97 535 200 3.38 / 505.15 2 4
7 8 0.04 175 14.96 293 767 4.15 / 505.92 2 9
Average= 4.22
(KJ/cycle)

Cycle 118 GMT 26/ 9/2023 14:30: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.16 30 14.91 479 214 0.21 / 497.72 2 3
2 12 1163.04 3 15.08 2100 95 0.31 / 497.81 2 3
3 7 2009.08 33 14.63 3167 1529 1.84 / 499.34 2 3
4 13 1555.88 25 14.63 2559 936 2.77 / 500.28 2 4
5 13 692.80 25 14.82 1345 498 3.27 / 500.78 2 3
6 13 127.20 25 14.97 514 192 3.46 / 500.97 2 3
7 8 0.04 175 14.96 306 801 4.27 / 501.77 2 11
Average= 4.22
(KJ/cycle)

Cycle 117 GMT 16/ 9/2023 16:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.80 30 14.91 470 210 0.21 / 493.45 2 3
2 12 1169.60 3 15.08 2108 95 0.31 / 493.55 2 3
3 7 2005.80 33 14.62 3153 1521 1.83 / 495.07 2 4
4 13 1418.64 25 14.67 2374 871 2.70 / 495.94 2 3
5 13 604.00 25 14.85 1230 457 3.15 / 496.39 2 4
6 13 127.84 25 14.96 514 192 3.35 / 496.59 2 3
7 13 31.92 25 14.99 354 133 3.48 / 496.72 2 4
8 8 0.00 175 14.95 300 785 4.26 / 497.50 2 3
Average= 4.22
(KJ/cycle)

Cycle 116 GMT 6/ 9/2023 18:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.84 30 14.92 461 206 0.21 / 489.22 2 3
2 12 1179.84 3 15.07 2105 95 0.30 / 489.31 2 3
3 7 2007.92 33 14.62 3137 1513 1.81 / 490.83 2 3
4 13 1577.12 25 14.64 2573 942 2.76 / 491.77 2 3
5 13 702.40 25 14.82 1358 503 3.26 / 492.27 2 3
6 13 132.16 25 14.96 515 193 3.45 / 492.46 2 3
7 8 0.04 175 14.95 297 777 4.23 / 493.24 2 3
Average= 4.22
(KJ/cycle)

Cycle 115 GMT 27/ 8/2023 21:11: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 121.52 30 14.91 480 215 0.21 / 485.07 2 3
2 12 1182.72 3 15.08 2129 96 0.31 / 485.17 2 3
3 7 2009.52 33 14.61 3142 1515 1.83 / 486.69 2 4
4 13 1479.20 25 14.65 2439 893 2.72 / 487.58 2 3
5 13 633.40 25 14.83 1260 467 3.19 / 488.05 2 3
6 13 131.20 25 14.96 514 192 3.38 / 488.24 2 3
7 8 0.32 175 14.96 295 772 4.15 / 489.01 2 9
Average= 4.22
(KJ/cycle)

Cycle 114 GMT 17/ 8/2023 23:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.00 30 14.91 473 212 0.21 / 480.74 2 3
2 12 1181.36 3 15.08 2117 96 0.31 / 480.84 2 3
3 7 2003.80 33 14.62 3142 1516 1.82 / 482.36 2 3
4 13 1477.08 25 14.66 2436 893 2.72 / 483.25 2 3
5 13 782.16 25 14.79 1471 544 3.26 / 483.79 2 4
6 13 109.00 25 14.98 479 179 3.44 / 483.97 2 3
7 13 26.96 25 14.98 337 126 3.57 / 484.10 2 4
8 8 0.08 175 14.95 291 761 4.33 / 484.86 2 11
Average= 4.22
(KJ/cycle)

Cycle 113 GMT 8/ 8/2023 2: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.88 30 14.91 462 207 0.21 / 476.46 2 3
2 12 1168.00 3 15.07 2093 95 0.30 / 476.55 2 3
3 7 2005.76 33 14.63 3143 1517 1.82 / 478.07 2 3
4 13 1559.12 25 14.64 2550 933 2.75 / 479.00 2 3
5 13 784.80 25 14.79 1484 549 3.30 / 479.55 2 3
6 13 164.88 25 14.94 571 213 3.51 / 479.77 2 3
7 8 0.04 175 14.96 293 767 4.28 / 480.53 2 3
Average= 4.22
(KJ/cycle)

Cycle 112 GMT 29/ 7/2023 4:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.28 30 14.92 469 210 0.21 / 472.25 2 3
2 12 1180.20 3 15.08 2126 96 0.31 / 472.35 2 2
3 7 2004.80 34 14.64 3139 1562 1.87 / 473.91 2 3
4 13 1474.24 25 14.67 2441 895 2.76 / 474.80 2 3
5 13 646.12 25 14.84 1279 475 3.24 / 475.28 2 4
6 13 146.96 25 14.98 541 203 3.44 / 475.48 2 3
7 8 -0.08 175 14.97 294 770 4.21 / 476.25 2 6
Average= 4.21
(KJ/cycle)

Cycle 111 GMT 19/ 7/2023 6:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.40 30 14.92 454 203 0.20 / 468.07 2 3
2 12 1173.72 3 15.07 2112 95 0.30 / 468.16 2 2
3 7 2002.64 33 14.63 3141 1516 1.82 / 469.68 2 3
4 13 1468.96 25 14.67 2434 893 2.71 / 470.57 2 3
5 13 713.72 25 14.82 1378 511 3.22 / 471.08 2 3
6 13 125.48 25 14.98 504 189 3.41 / 471.27 2 3
7 8 0.08 175 14.97 294 770 4.18 / 472.04 2 7
Average= 4.21
(KJ/cycle)

Cycle 110 GMT 9/ 7/2023 9:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.04 30 14.92 480 215 0.21 / 463.63 2 3
2 12 1169.00 3 15.10 2105 95 0.31 / 463.72 2 2
3 7 2003.04 33 14.63 3135 1514 1.82 / 465.24 2 3
4 13 1559.20 25 14.65 2542 931 2.75 / 466.17 2 3
5 13 687.92 25 14.84 1340 497 3.25 / 466.67 2 4
6 13 120.36 25 14.99 496 186 3.44 / 466.85 2 2
7 13 29.88 25 14.99 346 130 3.57 / 466.98 2 2
8 8 0.00 175 14.96 295 772 4.34 / 467.75 2 4
9 14 0.00 25 14.93 293 109 4.45 / 467.86 3 4
Average= 4.21
(KJ/cycle)

Cycle 109 GMT 29/ 6/2023 11:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.32 29 14.91 468 202 0.20 / 459.39 2 3
2 12 1176.28 3 15.07 2098 95 0.30 / 459.49 2 3
3 7 2008.48 34 14.61 3141 1560 1.86 / 461.05 2 3
4 13 1554.00 25 14.64 2538 929 2.79 / 461.97 2 3
5 13 677.00 25 14.83 1323 491 3.28 / 462.47 2 4
6 13 112.48 25 14.98 484 181 3.46 / 462.65 2 3
7 8 0.12 175 14.97 293 768 4.23 / 463.41 2 3
Average= 4.21
(KJ/cycle)

Cycle 108 GMT 19/ 6/2023 14:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.72 29 14.92 466 202 0.20 / 455.26 2 3
2 12 1169.96 3 15.08 2099 95 0.30 / 455.36 2 3
3 7 2008.52 33 14.62 3127 1509 1.81 / 456.87 2 3
4 13 1484.48 25 14.67 2437 894 2.70 / 457.76 2 3
5 13 631.28 25 14.86 1256 467 3.17 / 458.23 2 5
6 13 134.84 25 14.98 522 195 3.36 / 458.42 2 4
7 8 0.04 175 14.97 293 768 4.13 / 459.19 2 3
Average= 4.21
(KJ/cycle)

Cycle 107 GMT 9/ 6/2023 16:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.32 29 14.94 470 204 0.20 / 451.12 2 3
2 12 1184.96 3 15.08 2125 96 0.30 / 451.22 2 3
3 7 2003.00 33 14.65 3143 1519 1.82 / 452.74 2 3
4 13 1402.48 25 14.70 2340 860 2.68 / 453.60 2 3
5 13 654.96 25 14.85 1294 480 3.16 / 454.08 2 3
6 13 152.40 25 14.97 552 207 3.37 / 454.29 2 3
7 8 0.00 175 14.97 295 773 4.14 / 455.06 2 4
Average= 4.21
(KJ/cycle)

Cycle 106 GMT 30/ 5/2023 18:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.76 29 14.94 471 204 0.20 / 446.96 2 3
2 12 1169.08 3 15.10 2079 94 0.30 / 447.06 2 3
3 7 2007.36 33 14.64 3143 1518 1.82 / 448.58 2 3
4 13 1474.16 25 14.68 2438 895 2.71 / 449.47 2 3
5 13 630.76 25 14.85 1262 469 3.18 / 449.94 2 3
6 13 138.56 25 14.98 530 198 3.38 / 450.14 2 3
7 8 0.00 175 14.99 298 782 4.16 / 450.92 2 3
Average= 4.21
(KJ/cycle)

Cycle 105 GMT 20/ 5/2023 21:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.36 29 14.93 471 204 0.20 / 442.69 2 3
2 12 1176.48 3 15.07 2107 95 0.30 / 442.79 2 3
3 7 2003.36 33 14.65 3139 1518 1.82 / 444.31 2 3
4 13 1560.16 25 14.66 2557 937 2.75 / 445.24 2 3
5 13 771.44 25 14.81 1464 542 3.30 / 445.78 2 3
6 13 97.00 25 15.01 469 176 3.47 / 445.96 2 3
7 8 0.04 175 14.99 305 800 4.27 / 446.76 2 9
Average= 4.21
(KJ/cycle)

Cycle 104 GMT 10/ 5/2023 23:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.08 29 14.93 467 202 0.20 / 438.36 2 3
2 12 1158.96 3 15.10 2085 94 0.30 / 438.46 2 3
3 7 2002.44 33 14.64 3142 1518 1.81 / 439.97 2 3
4 13 1553.08 25 14.66 2553 936 2.75 / 440.91 2 3
5 13 692.20 25 14.84 1350 501 3.25 / 441.41 2 3
6 13 91.80 25 15.00 455 171 3.42 / 441.58 2 3
7 13 22.12 25 15.02 334 125 3.55 / 441.71 2 4
8 8 0.12 175 14.98 298 781 4.33 / 442.49 2 5
Average= 4.21
(KJ/cycle)

Cycle 103 GMT 1/ 5/2023 1:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.92 29 14.93 467 202 0.20 / 433.99 2 3
2 12 1178.04 3 15.09 2128 96 0.30 / 434.09 2 3
3 7 2004.40 33 14.66 3146 1522 1.82 / 435.61 2 3
4 13 1564.60 25 14.67 2566 941 2.76 / 436.55 2 3
5 13 702.48 25 14.84 1370 508 3.27 / 437.06 2 3
6 13 106.52 25 15.01 481 180 3.45 / 437.24 2 3
7 13 22.72 25 15.02 339 127 3.58 / 437.37 2 4
8 8 -0.04 175 14.98 302 792 4.37 / 438.16 2 3
Average= 4.21
(KJ/cycle)

Cycle 102 GMT 21/ 4/2023 4:25: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.92 29 14.92 465 201 0.20 / 429.69 2 3
2 12 1170.12 3 15.09 2104 95 0.30 / 429.79 2 3
3 7 2002.92 33 14.64 3133 1514 1.81 / 431.30 2 3
4 13 1541.76 25 14.66 2519 923 2.73 / 432.22 2 4
5 13 604.08 25 14.87 1221 454 3.19 / 432.68 2 3
6 13 122.04 25 15.00 507 190 3.38 / 432.87 2 3
7 13 28.24 25 15.01 347 130 3.51 / 433.00 2 4
8 8 -0.04 175 14.98 302 792 4.30 / 433.79 2 5
Average= 4.21
(KJ/cycle)

Cycle 101 GMT 11/ 4/2023 6:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.40 29 14.93 467 202 0.20 / 425.31 2 3
2 12 1175.64 3 15.08 2109 95 0.30 / 425.40 2 3
3 7 2009.72 33 14.64 3145 1519 1.82 / 426.92 2 3
4 13 1568.44 25 14.65 2576 943 2.76 / 427.86 2 3
5 13 703.12 25 14.84 1374 510 3.27 / 428.37 2 3
6 13 113.52 25 15.01 495 186 3.46 / 428.56 2 3
7 13 30.04 25 15.01 352 132 3.59 / 428.69 2 4
8 8 0.04 175 14.98 305 800 4.39 / 429.49 2 3
Average= 4.21
(KJ/cycle)

Cycle 100 GMT 1/ 4/2023 9: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.52 29 14.94 470 204 0.20 / 420.97 2 3
2 12 1168.92 3 15.09 2106 95 0.30 / 421.06 2 3
3 7 2003.92 33 14.65 3144 1520 1.82 / 422.58 2 3
4 13 1483.72 25 14.68 2458 902 2.72 / 423.48 2 4
5 13 651.72 25 14.86 1290 479 3.20 / 423.96 2 3
6 13 149.28 25 14.99 548 205 3.41 / 424.17 2 3
7 13 38.20 25 15.02 367 138 3.54 / 424.31 2 4
8 8 -0.12 175 14.98 304 797 4.34 / 425.10 2 13
Average= 4.21
(KJ/cycle)

Cycle 99 GMT 22/ 3/2023 11:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.68 29 14.93 468 203 0.20 / 416.69 2 3
2 12 1160.72 3 15.12 2084 95 0.30 / 416.78 2 3
3 7 2008.60 33 14.63 3142 1517 1.81 / 418.30 2 3
4 13 1473.40 25 14.69 2439 896 2.71 / 419.20 2 3
5 13 629.64 25 14.88 1258 468 3.18 / 419.66 2 3
6 13 130.72 25 15.01 516 194 3.37 / 419.86 2 2
7 13 33.08 25 15.02 352 132 3.50 / 419.99 2 3
8 8 0.04 175 14.99 295 774 4.28 / 420.76 2 4
Average= 4.21
(KJ/cycle)

Cycle 98 GMT 12/ 3/2023 13:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.88 29 14.94 466 202 0.20 / 412.37 2 3
2 12 1172.36 3 15.11 2104 95 0.30 / 412.46 2 3
3 7 2006.80 33 14.64 3139 1517 1.81 / 413.98 2 3
4 13 1484.28 25 14.68 2448 898 2.71 / 414.88 2 3
5 13 719.52 25 14.84 1387 515 3.23 / 415.39 2 3
6 13 109.80 25 15.00 485 182 3.41 / 415.57 2 3
7 13 32.00 25 15.02 350 131 3.54 / 415.71 2 4
8 8 0.00 175 14.98 298 781 4.32 / 416.49 2 9
Average= 4.21
(KJ/cycle)

Cycle 97 GMT 2/ 3/2023 15:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.32 29 14.94 478 207 0.21 / 408.07 2 3
2 12 1170.52 3 15.12 2111 96 0.30 / 408.17 2 3
3 7 2004.72 33 14.67 3137 1519 1.82 / 409.68 2 3
4 13 1462.52 25 14.70 2429 893 2.71 / 410.58 2 4
5 13 697.64 25 14.85 1359 505 3.22 / 411.08 2 3
6 13 99.52 25 15.01 469 176 3.39 / 411.26 2 3
7 13 26.16 25 15.03 342 129 3.52 / 411.39 2 2
8 8 0.08 175 14.99 297 779 4.30 / 412.16 2 8
Average= 4.21
(KJ/cycle)

Cycle 96 GMT 20/ 2/2023 17:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.88 29 14.93 466 202 0.20 / 403.73 2 3
2 12 1166.16 3 15.10 2082 94 0.30 / 403.82 2 3
3 7 2003.44 33 14.65 3131 1514 1.81 / 405.34 2 3
4 13 1562.16 25 14.66 2551 935 2.74 / 406.27 2 2
5 13 699.64 25 14.85 1354 503 3.25 / 406.77 2 4
6 13 94.60 25 15.01 464 174 3.42 / 406.95 2 2
7 13 24.08 25 15.02 341 128 3.55 / 407.08 2 3
8 8 0.08 175 14.98 300 786 4.34 / 407.86 2 11
Average= 4.20
(KJ/cycle)

Cycle 95 GMT 10/ 2/2023 20:20: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.28 29 14.94 470 204 0.20 / 399.35 2 3
2 12 1180.92 3 15.10 2118 96 0.30 / 399.45 2 3
3 7 2007.44 34 14.67 3143 1568 1.87 / 401.01 2 3
4 13 1540.24 25 14.67 2526 926 2.79 / 401.94 2 3
5 13 680.24 25 14.85 1335 496 3.29 / 402.44 2 3
6 13 89.28 25 15.02 457 172 3.46 / 402.61 2 3
7 13 23.16 25 15.02 343 129 3.59 / 402.74 2 5
8 8 -0.04 175 14.99 301 790 4.38 / 403.53 2 3
Average= 4.20
(KJ/cycle)

Cycle 94 GMT 31/ 1/2023 22:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.92 29 14.95 458 199 0.20 / 395.06 2 3
2 12 1169.36 3 15.11 2100 95 0.29 / 395.15 2 2
3 7 2002.28 33 14.66 3134 1516 1.81 / 396.67 2 3
4 13 1461.84 25 14.71 2415 888 2.70 / 397.55 2 4
5 13 689.28 25 14.87 1341 499 3.20 / 398.05 2 3
6 13 84.44 25 15.03 451 169 3.37 / 398.22 2 3
7 13 19.28 25 15.03 337 127 3.49 / 398.35 2 5
8 8 -0.12 175 15.00 304 798 4.29 / 399.15 2 3
Average= 4.20
(KJ/cycle)

Cycle 93 GMT 22/ 1/2023 1: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.00 29 14.96 459 199 0.20 / 390.85 2 3
2 12 1177.68 3 15.10 2102 95 0.29 / 390.95 2 3
3 7 2003.32 33 14.65 3133 1515 1.81 / 392.46 2 3
4 13 1565.76 25 14.68 2553 937 2.75 / 393.40 2 4
5 13 685.92 25 14.86 1338 497 3.24 / 393.90 2 3
6 13 92.24 25 15.02 460 173 3.42 / 394.07 2 3
7 8 -0.04 175 15.01 299 785 4.20 / 394.86 2 3
Average= 4.20
(KJ/cycle)

Cycle 92 GMT 12/ 1/2023 3:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.08 29 14.96 463 201 0.20 / 386.69 2 3
2 12 1183.28 3 15.11 2109 96 0.30 / 386.78 2 3
3 7 2004.88 33 14.67 3126 1513 1.81 / 388.30 2 3
4 13 1488.92 25 14.70 2455 902 2.71 / 389.20 2 3
5 13 707.56 25 14.86 1368 508 3.22 / 389.71 2 3
6 13 95.40 25 15.02 464 174 3.39 / 389.88 2 3
7 8 0.00 175 15.01 295 775 4.17 / 390.66 2 7
Average= 4.20
(KJ/cycle)

Cycle 91 GMT 2/ 1/2023 6: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.04 29 14.96 455 197 0.20 / 382.58 2 3
2 12 1174.88 3 15.13 2108 96 0.29 / 382.68 2 3
3 7 2003.20 33 14.67 3132 1516 1.81 / 384.19 2 3
4 13 1403.08 25 14.71 2336 859 2.67 / 385.05 2 4
5 13 653.52 25 14.87 1291 480 3.15 / 385.53 2 3
6 13 73.76 25 15.03 428 161 3.31 / 385.69 2 4
7 8 0.08 175 15.00 302 793 4.10 / 386.49 2 6
Average= 4.20
(KJ/cycle)

Cycle 90 GMT 23/12/2022 8:18: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.20 29 14.97 459 199 0.20 / 378.35 2 3
2 12 1166.20 3 15.12 2091 95 0.29 / 378.45 2 3
3 7 2005.56 33 14.68 3129 1516 1.81 / 379.97 2 3
4 13 1561.16 25 14.69 2549 936 2.75 / 380.90 2 4
5 13 779.72 25 14.85 1468 545 3.29 / 381.45 2 3
6 13 77.64 25 15.04 433 163 3.45 / 381.61 2 3
7 8 -0.08 175 15.01 295 775 4.23 / 382.38 2 8
Average= 4.20
(KJ/cycle)

Cycle 89 GMT 13/12/2022 10:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.24 29 14.97 472 205 0.20 / 374.21 2 3
2 12 1171.84 3 15.11 2118 96 0.30 / 374.30 2 3
3 7 2006.56 33 14.67 3141 1521 1.82 / 375.82 2 3
4 13 1493.72 25 14.71 2466 907 2.73 / 376.73 2 3
5 13 645.36 25 14.87 1283 477 3.21 / 377.21 2 3
6 13 79.76 25 15.04 437 164 3.37 / 377.37 2 2
7 8 0.08 175 15.02 299 786 4.16 / 378.16 2 13
Average= 4.20
(KJ/cycle)

Cycle 88 GMT 3/12/2022 12:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.92 29 14.98 465 202 0.20 / 370.04 2 3
2 12 1163.92 3 15.11 2081 94 0.30 / 370.13 2 3
3 7 2006.60 33 14.66 3139 1519 1.81 / 371.65 2 3
4 13 1556.96 25 14.68 2548 935 2.75 / 372.59 2 3
5 13 592.04 25 14.90 1200 447 3.20 / 373.03 2 3
6 13 96.76 25 15.04 466 175 3.37 / 373.21 2 4
7 8 -0.08 175 15.02 301 791 4.16 / 374.00 2 3
Average= 4.20
(KJ/cycle)

Cycle 87 GMT 23/11/2022 15:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.40 29 14.97 471 204 0.20 / 365.83 2 3
2 12 1162.32 3 15.13 2088 95 0.30 / 365.93 2 3
3 7 2006.96 33 14.67 3145 1523 1.82 / 367.45 2 3
4 13 1496.08 25 14.70 2474 909 2.73 / 368.36 2 3
5 13 729.24 25 14.85 1407 522 3.25 / 368.88 2 4
6 13 72.20 25 15.04 427 161 3.41 / 369.04 2 2
7 8 0.24 175 15.03 302 794 4.21 / 369.84 2 5
Average= 4.20
(KJ/cycle)

Cycle 86 GMT 13/11/2022 17:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.00 29 15.00 467 203 0.20 / 361.66 2 3
2 12 1165.36 3 15.10 2085 94 0.30 / 361.75 2 3
3 7 2002.84 33 14.66 3133 1516 1.81 / 363.27 2 3
4 13 1553.08 25 14.68 2537 931 2.74 / 364.20 2 2
5 13 602.40 25 14.91 1221 455 3.20 / 364.65 2 3
6 13 97.92 25 15.04 470 177 3.38 / 364.83 2 3
7 8 0.00 175 15.02 304 799 4.18 / 365.63 2 7
Average= 4.20
(KJ/cycle)

Cycle 85 GMT 3/11/2022 20: 2: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.72 29 15.00 460 200 0.20 / 357.45 2 3
2 12 1186.68 3 15.12 2126 96 0.30 / 357.54 2 3
3 7 2002.56 34 14.67 3135 1564 1.86 / 359.11 2 3
4 13 1534.00 25 14.69 2523 927 2.79 / 360.03 2 3
5 13 593.92 25 14.91 1208 450 3.24 / 360.48 2 3
6 13 100.56 25 15.05 468 176 3.41 / 360.66 2 2
7 8 0.08 175 15.04 302 795 4.21 / 361.45 2 5
Average= 4.20
(KJ/cycle)

Cycle 84 GMT 24/10/2022 22:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.08 29 14.99 468 203 0.20 / 353.31 2 3
2 12 1167.40 3 15.11 2085 95 0.30 / 353.41 2 3
3 7 2011.44 33 14.67 3146 1523 1.82 / 354.93 2 3
4 13 1487.32 25 14.70 2457 903 2.72 / 355.83 2 3
5 13 641.96 25 14.89 1274 474 3.20 / 356.31 2 3
6 13 80.48 25 15.06 436 164 3.36 / 356.47 2 3
7 8 0.08 175 15.04 294 774 4.14 / 357.25 2 3
Average= 4.20
(KJ/cycle)

Cycle 83 GMT 15/10/2022 0:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.80 29 14.99 477 207 0.21 / 349.23 2 3
2 12 1172.56 3 15.12 2102 95 0.30 / 349.32 2 3
3 7 2005.56 33 14.66 3134 1516 1.82 / 350.84 2 3
4 13 1399.68 25 14.72 2339 861 2.68 / 351.70 2 3
5 13 579.00 25 14.91 1189 443 3.12 / 352.14 2 3
6 13 85.16 25 15.04 449 169 3.29 / 352.31 2 3
7 8 0.04 175 15.03 303 797 4.09 / 353.11 2 4
Average= 4.20
(KJ/cycle)

Cycle 82 GMT 5/10/2022 2:58: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.48 29 14.99 475 206 0.21 / 345.12 2 2
2 12 1146.28 3 15.12 2061 93 0.30 / 345.22 2 3
3 7 2006.88 33 14.67 3144 1522 1.82 / 346.74 2 3
4 13 1398.12 25 14.73 2336 860 2.68 / 347.60 2 3
5 13 591.16 25 14.93 1203 449 3.13 / 348.05 2 3
6 13 85.44 25 15.07 449 169 3.30 / 348.22 2 3
7 8 0.00 175 15.04 305 803 4.10 / 349.02 2 8
Average= 4.21
(KJ/cycle)

Cycle 81 GMT 25/ 9/2022 5: 6: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.88 29 15.00 474 206 0.21 / 340.92 2 3
2 12 1204.88 3 15.12 2160 98 0.30 / 341.02 2 3
3 7 2003.68 33 14.68 3137 1520 1.82 / 342.54 2 4
4 13 1488.28 25 14.72 2459 905 2.73 / 343.44 2 3
5 13 713.92 25 14.88 1384 515 3.24 / 343.96 2 4
6 13 54.44 25 15.07 405 153 3.40 / 344.11 2 2
7 8 -0.04 175 15.05 306 806 4.20 / 344.92 2 3
Average= 4.21
(KJ/cycle)

Cycle 80 GMT 15/ 9/2022 7: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 29 15.00 461 201 0.20 / 336.75 2 3
2 12 1161.64 3 15.15 2080 95 0.30 / 336.84 2 3
3 7 2008.56 33 14.69 3164 1534 1.83 / 338.37 2 3
4 13 1424.48 25 14.73 2379 876 2.70 / 339.25 2 3
5 13 685.08 25 14.90 1348 502 3.21 / 339.75 2 5
6 13 51.92 25 15.08 400 151 3.36 / 339.90 2 2
7 8 0.16 175 15.06 308 812 4.17 / 340.72 2 5
Average= 4.21
(KJ/cycle)

Cycle 79 GMT 5/ 9/2022 9: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.04 29 15.02 458 199 0.20 / 332.55 2 3
2 12 1336.08 3 15.06 2343 106 0.31 / 332.66 2 3
3 7 2004.04 34 14.66 3130 1560 1.87 / 334.22 2 3
4 13 1468.52 25 14.71 2426 892 2.76 / 335.11 2 3
5 13 641.08 25 14.90 1270 473 3.23 / 335.58 2 3
6 13 59.20 25 15.07 411 155 3.39 / 335.74 2 3
7 8 0.04 175 15.04 307 808 4.19 / 336.55 2 6
Average= 4.21
(KJ/cycle)

Cycle 78 GMT 26/ 8/2022 11:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.68 29 15.02 462 201 0.20 / 328.22 2 3
2 12 1173.96 3 15.13 2095 95 0.30 / 328.31 2 3
3 7 2002.20 33 14.69 3138 1521 1.82 / 329.83 2 3
4 13 1468.92 25 14.74 2438 898 2.72 / 330.73 2 3
5 13 791.96 25 14.88 1485 552 3.27 / 331.28 2 4
6 13 89.44 25 15.08 455 172 3.44 / 331.46 2 3
7 8 -0.04 175 15.07 297 783 4.22 / 332.24 2 5
8 14 -0.04 25 15.04 299 112 4.34 / 332.35 3 10
Average= 4.21
(KJ/cycle)

Cycle 77 GMT 16/ 8/2022 13:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.48 29 15.03 472 206 0.21 / 324.07 2 3
2 12 1164.68 3 15.14 2111 96 0.30 / 324.17 2 3
3 7 2002.40 33 14.68 3131 1517 1.82 / 325.69 2 2
4 13 1459.52 25 14.72 2422 891 2.71 / 326.58 2 3
5 13 606.08 25 14.92 1224 457 3.17 / 327.04 2 3
6 13 102.32 25 15.08 476 179 3.35 / 327.21 2 3
7 8 0.08 175 15.07 304 802 4.15 / 328.02 2 10
Average= 4.21
(KJ/cycle)

Cycle 76 GMT 6/ 8/2022 16: 7: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.24 29 15.03 458 200 0.20 / 319.87 2 3
2 12 1169.00 3 15.12 2093 95 0.29 / 319.97 2 3
3 7 2006.00 33 14.69 3147 1526 1.82 / 321.49 2 3
4 13 1469.08 25 14.73 2435 897 2.72 / 322.39 2 3
5 13 705.92 25 14.90 1370 510 3.23 / 322.90 2 3
6 13 96.32 25 15.08 466 176 3.40 / 323.07 2 3
7 8 -0.04 175 15.08 301 794 4.20 / 323.87 2 5
Average= 4.21
(KJ/cycle)

Cycle 75 GMT 27/ 7/2022 18:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.28 29 15.04 457 199 0.20 / 315.69 2 3
2 12 1168.84 3 15.12 2092 95 0.29 / 315.79 2 3
3 7 2006.84 33 14.67 3140 1520 1.81 / 317.31 2 3
4 13 1465.72 25 14.72 2415 889 2.70 / 318.20 2 3
5 13 765.20 25 14.87 1445 537 3.24 / 318.74 2 3
6 13 70.00 25 15.09 420 158 3.40 / 318.89 2 3
7 8 0.04 175 15.07 295 778 4.18 / 319.67 2 5
Average= 4.21
(KJ/cycle)

Cycle 74 GMT 17/ 7/2022 20:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.40 29 15.03 473 206 0.21 / 311.45 2 2
2 12 1180.16 3 15.16 2130 97 0.30 / 311.55 2 3
3 7 2006.52 33 14.67 3143 1522 1.82 / 313.07 2 3
4 13 1474.00 25 14.72 2442 899 2.72 / 313.97 2 4
5 13 622.64 25 14.95 1250 467 3.19 / 314.44 2 3
6 13 70.20 25 15.10 425 160 3.35 / 314.60 2 3
7 8 -0.04 175 15.08 298 786 4.14 / 315.38 2 5
8 14 -0.04 25 15.07 299 113 4.25 / 315.50 2 6
Average= 4.21
(KJ/cycle)

Cycle 73 GMT 7/ 7/2022 22:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.20 29 15.03 470 205 0.20 / 307.21 2 3
2 12 1166.00 3 15.14 2098 95 0.30 / 307.31 2 2
3 7 2003.32 33 14.70 3135 1521 1.82 / 308.83 2 3
4 13 1569.88 25 14.71 2571 945 2.77 / 309.78 2 3
5 13 696.72 25 14.91 1358 506 3.27 / 310.28 2 3
6 13 100.24 25 15.09 473 178 3.45 / 310.46 2 3
7 8 0.00 175 15.09 297 784 4.24 / 311.25 2 4
Average= 4.21
(KJ/cycle)

Cycle 72 GMT 28/ 6/2022 1: 7: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.76 29 15.04 477 208 0.21 / 303.03 2 3
2 12 1175.76 3 15.13 2099 95 0.30 / 303.13 2 3
3 7 2006.80 33 14.69 3145 1525 1.83 / 304.65 2 4
4 13 1485.72 25 14.72 2453 903 2.73 / 305.56 2 4
5 13 627.12 25 14.94 1257 469 3.20 / 306.03 2 3
6 13 124.28 25 15.08 509 192 3.39 / 306.22 2 2
7 8 -0.04 175 15.08 300 792 4.18 / 307.01 2 4
Average= 4.21
(KJ/cycle)

Cycle 71 GMT 18/ 6/2022 3:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.88 29 15.04 479 209 0.21 / 298.74 2 3
2 12 1169.24 3 15.13 2099 95 0.30 / 298.84 2 3
3 7 2003.00 33 14.69 3147 1526 1.83 / 300.36 2 3
4 13 1552.56 25 14.71 2541 934 2.76 / 301.30 2 3
5 13 618.32 25 14.94 1243 464 3.23 / 301.76 2 3
6 13 79.64 25 15.11 439 166 3.39 / 301.93 2 4
7 8 0.12 175 15.10 298 787 4.18 / 302.71 2 5
8 14 0.12 25 15.08 300 113 4.29 / 302.83 2 3
Average= 4.21
(KJ/cycle)

Cycle 70 GMT 8/ 6/2022 5:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.80 29 15.04 479 209 0.21 / 294.34 2 3
2 12 1173.20 3 15.13 2117 96 0.31 / 294.43 2 3
3 7 2006.36 33 14.69 3154 1529 1.83 / 295.96 2 3
4 13 1483.12 25 14.74 2452 904 2.74 / 296.86 2 3
5 13 721.44 25 14.93 1396 521 3.26 / 297.39 2 4
6 13 109.92 25 15.09 501 189 3.45 / 297.57 2 3
7 13 24.52 25 15.11 354 134 3.58 / 297.71 2 2
8 8 0.20 175 15.08 312 823 4.40 / 298.53 2 10
Average= 4.20
(KJ/cycle)

Cycle 69 GMT 29/ 5/2022 7:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.48 29 15.04 481 210 0.21 / 289.88 2 3
2 12 1177.84 3 15.13 2123 96 0.31 / 289.98 2 2
3 7 2003.52 33 14.69 3150 1527 1.83 / 291.51 2 3
4 13 1561.52 25 14.71 2560 941 2.77 / 292.45 2 3
5 13 769.40 25 14.90 1471 548 3.32 / 293.00 2 4
6 13 77.72 25 15.11 451 170 3.49 / 293.17 2 3
7 13 22.60 25 15.12 353 133 3.63 / 293.30 2 3
8 8 0.12 175 15.08 313 826 4.45 / 294.13 2 7
Average= 4.20
(KJ/cycle)

Cycle 68 GMT 19/ 5/2022 9:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.40 28 15.06 457 193 0.19 / 285.52 2 3
2 12 1180.48 3 15.13 2128 97 0.29 / 285.61 2 3
3 7 2002.12 33 14.70 3147 1527 1.82 / 287.14 2 3
4 13 1557.20 25 14.71 2555 940 2.76 / 288.08 2 3
5 13 604.72 25 14.96 1229 460 3.22 / 288.54 2 3
6 13 99.00 25 15.11 479 181 3.40 / 288.72 2 2
7 13 24.08 25 15.12 352 133 3.53 / 288.85 2 3
8 8 0.12 175 15.09 311 821 4.35 / 289.67 2 6
Average= 4.20
(KJ/cycle)

Cycle 67 GMT 9/ 5/2022 11:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 28 15.04 472 199 0.20 / 281.17 2 2
2 12 1164.08 3 15.15 2093 95 0.29 / 281.27 2 3
3 7 2006.48 33 14.70 3155 1530 1.82 / 282.80 2 3
4 13 1561.76 25 14.73 2563 944 2.77 / 283.74 2 3
5 13 615.24 25 14.97 1241 464 3.23 / 284.21 2 3
6 13 107.64 25 15.12 488 184 3.42 / 284.39 2 3
7 13 25.72 25 15.13 346 131 3.55 / 284.52 2 2
8 8 -0.08 175 15.10 304 803 4.35 / 285.32 2 11
Average= 4.20
(KJ/cycle)

Cycle 66 GMT 29/ 4/2022 14: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.24 28 15.07 462 195 0.19 / 276.78 2 3
2 12 1334.04 3 15.09 2357 107 0.30 / 276.89 2 3
3 7 2001.76 33 14.69 3146 1525 1.83 / 278.41 2 3
4 13 1563.92 25 14.72 2568 945 2.77 / 279.36 2 3
5 13 698.28 25 14.93 1370 511 3.28 / 279.87 2 3
6 13 64.00 25 15.13 421 159 3.44 / 280.03 2 3
7 13 23.68 25 15.13 351 133 3.58 / 280.16 2 3
8 8 0.00 175 15.10 308 814 4.39 / 280.97 2 9
Average= 4.19
(KJ/cycle)

Cycle 65 GMT 19/ 4/2022 16:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.32 28 15.07 460 194 0.19 / 272.47 2 2
2 12 1315.84 3 15.10 2320 105 0.30 / 272.58 2 3
3 7 2006.96 33 14.71 3158 1533 1.83 / 274.11 2 3
4 13 1465.80 25 14.76 2435 899 2.73 / 275.01 2 3
5 13 621.60 25 14.96 1249 467 3.20 / 275.47 2 4
6 13 107.64 25 15.11 490 185 3.38 / 275.66 2 3
7 13 22.36 25 15.14 339 128 3.51 / 275.79 2 2
8 8 0.00 175 15.11 301 796 4.31 / 276.58 2 3
Average= 4.19
(KJ/cycle)

Cycle 64 GMT 9/ 4/2022 18:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.60 28 15.06 464 196 0.20 / 268.22 2 3
2 12 1167.12 3 15.15 2116 96 0.29 / 268.31 2 2
3 7 2002.20 33 14.69 3137 1521 1.81 / 269.83 2 3
4 13 1474.72 25 14.75 2439 899 2.71 / 270.73 2 3
5 13 626.32 25 14.96 1257 470 3.18 / 271.20 2 3
6 13 68.88 25 15.13 423 160 3.34 / 271.36 2 3
7 13 20.16 25 15.14 334 126 3.47 / 271.49 2 2
8 8 0.04 175 15.11 298 788 4.26 / 272.28 2 5
Average= 4.19
(KJ/cycle)

Cycle 63 GMT 30/ 3/2022 20:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.68 28 15.06 483 204 0.20 / 263.90 2 3
2 12 1165.24 3 15.16 2107 96 0.30 / 263.99 2 2
3 7 2006.88 33 14.72 3149 1530 1.83 / 265.52 2 2
4 13 1490.28 25 14.75 2462 908 2.74 / 266.43 2 3
5 13 640.72 25 14.97 1276 478 3.21 / 266.91 2 3
6 13 66.24 25 15.14 426 161 3.38 / 267.07 2 3
7 13 18.56 25 15.15 346 131 3.51 / 267.20 2 2
8 8 -0.04 175 15.10 310 819 4.33 / 268.02 2 3
Average= 4.19
(KJ/cycle)

Cycle 62 GMT 20/ 3/2022 22:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.40 28 15.08 460 194 0.19 / 259.57 2 3
2 12 1166.56 3 15.14 2101 95 0.29 / 259.66 2 3
3 7 2005.36 33 14.70 3151 1529 1.82 / 261.19 2 3
4 13 1461.56 25 14.76 2427 896 2.71 / 262.09 2 3
5 13 596.84 25 14.99 1226 459 3.17 / 262.55 2 4
6 13 86.84 25 15.15 460 174 3.35 / 262.72 2 3
7 13 20.80 25 15.15 347 131 3.48 / 262.85 2 3
8 8 0.00 175 15.11 318 841 4.32 / 263.69 2 5
Average= 4.19
(KJ/cycle)

Cycle 61 GMT 11/ 3/2022 0:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.40 28 15.08 478 202 0.20 / 255.24 2 3
2 12 1312.32 3 15.10 2323 105 0.31 / 255.34 2 3
3 7 2002.12 33 14.71 3159 1533 1.84 / 256.88 2 2
4 13 1466.08 25 14.76 2436 899 2.74 / 257.78 2 3
5 13 690.48 25 14.94 1356 506 3.25 / 258.28 2 5
6 13 81.28 25 15.14 449 170 3.42 / 258.45 2 2
7 13 24.72 25 15.14 343 130 3.55 / 258.58 2 3
8 8 -0.04 175 15.11 299 791 4.34 / 259.37 2 4
Average= 4.18
(KJ/cycle)

Cycle 60 GMT 1/ 3/2022 3: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.12 28 15.07 468 197 0.20 / 250.96 2 3
2 12 1167.04 3 15.14 2099 95 0.29 / 251.05 2 3
3 7 2003.40 33 14.70 3146 1526 1.82 / 252.58 2 3
4 13 1473.04 25 14.75 2448 903 2.72 / 253.48 2 3
5 13 551.52 25 15.01 1159 435 3.16 / 253.92 2 3
6 13 72.96 25 15.14 440 167 3.32 / 254.08 2 2
7 13 20.00 25 15.16 344 130 3.45 / 254.21 2 2
8 8 -0.04 175 15.11 312 825 4.28 / 255.04 2 3
Average= 4.18
(KJ/cycle)

Cycle 59 GMT 19/ 2/2022 5: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.24 28 15.09 463 196 0.20 / 246.61 2 3
2 12 1164.56 3 15.14 2117 96 0.29 / 246.70 2 3
3 7 2002.04 33 14.71 3144 1526 1.82 / 248.23 2 3
4 13 1475.00 25 14.76 2453 905 2.72 / 249.14 2 3
5 13 710.52 25 14.96 1381 516 3.24 / 249.65 2 3
6 13 95.84 25 15.14 468 177 3.42 / 249.83 2 2
7 13 27.44 25 15.15 345 131 3.55 / 249.96 2 4
8 8 0.04 175 15.13 302 800 4.35 / 250.76 2 5
Average= 4.18
(KJ/cycle)

Cycle 58 GMT 9/ 2/2022 7:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.72 28 15.09 472 199 0.20 / 242.32 2 3
2 12 1317.20 3 15.11 2337 106 0.31 / 242.42 2 3
3 7 2002.96 33 14.72 3157 1534 1.84 / 243.96 2 3
4 13 1402.16 25 14.79 2364 874 2.71 / 244.83 2 3
5 13 659.84 25 14.98 1314 492 3.21 / 245.32 2 4
6 13 97.04 25 15.15 468 177 3.38 / 245.50 2 2
7 13 30.44 25 15.15 350 133 3.51 / 245.63 2 2
8 8 0.08 175 15.13 295 781 4.30 / 246.41 2 5
Average= 4.18
(KJ/cycle)

Cycle 57 GMT 30/ 1/2022 9: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.68 28 15.08 476 201 0.20 / 238.00 2 3
2 12 1328.16 3 15.13 2340 106 0.31 / 238.11 2 3
3 7 2008.04 33 14.71 3158 1533 1.84 / 239.64 2 3
4 13 1471.64 25 14.76 2444 902 2.74 / 240.54 2 3
5 13 600.60 25 15.01 1228 461 3.20 / 241.00 2 3
6 13 116.12 25 15.15 497 188 3.39 / 241.19 2 3
7 13 30.28 25 15.17 353 134 3.52 / 241.33 2 2
8 8 0.16 175 15.14 298 790 4.31 / 242.12 2 8
Average= 4.17
(KJ/cycle)

Cycle 56 GMT 20/ 1/2022 11:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.68 28 15.10 480 203 0.20 / 233.67 2 3
2 12 1171.48 3 15.17 2115 96 0.30 / 233.76 2 3
3 7 2004.84 33 14.73 3155 1534 1.83 / 235.30 2 3
4 13 1398.60 25 14.79 2355 871 2.70 / 236.17 2 3
5 13 649.72 25 14.98 1300 487 3.19 / 236.65 2 3
6 13 137.52 25 15.14 541 205 3.40 / 236.86 2 3
7 13 32.44 25 15.17 363 138 3.53 / 237.00 2 2
8 8 0.04 175 15.13 304 805 4.34 / 237.80 2 4
Average= 4.17
(KJ/cycle)

Cycle 55 GMT 10/ 1/2022 13:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.96 28 15.10 467 197 0.20 / 229.34 2 3
2 12 1176.20 3 15.17 2129 97 0.29 / 229.44 2 3
3 7 2002.12 33 14.73 3142 1527 1.82 / 230.96 2 3
4 13 1480.88 25 14.78 2460 909 2.73 / 231.87 2 3
5 13 631.04 25 15.01 1265 475 3.21 / 232.35 2 3
6 13 125.92 25 15.15 512 194 3.40 / 232.54 2 3
7 13 30.32 25 15.17 351 133 3.53 / 232.67 2 3
8 8 -0.12 175 15.14 298 790 4.32 / 233.46 2 4
Average= 4.17
(KJ/cycle)

Cycle 54 GMT 31/12/2021 15:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.56 28 15.10 472 200 0.20 / 225.14 2 3
2 12 1163.28 3 15.17 2101 96 0.30 / 225.23 2 3
3 7 2006.80 33 14.71 3153 1531 1.83 / 226.76 2 3
4 13 1377.68 25 14.79 2317 857 2.68 / 227.62 2 3
5 13 543.28 25 15.02 1140 428 3.11 / 228.05 2 4
6 13 87.72 25 15.16 450 171 3.28 / 228.22 2 2
7 13 24.76 25 15.17 344 130 3.41 / 228.35 2 2
8 8 -0.08 175 15.14 299 792 4.20 / 229.14 2 3
Average= 4.17
(KJ/cycle)

Cycle 53 GMT 21/12/2021 17:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.00 28 15.10 481 203 0.20 / 220.84 2 3
2 12 1169.12 3 15.16 2110 96 0.30 / 220.93 2 3
3 7 2006.08 33 14.73 3157 1535 1.83 / 222.47 2 3
4 13 1476.92 25 14.77 2449 904 2.74 / 223.37 2 4
5 13 626.12 25 15.01 1266 475 3.21 / 223.85 2 3
6 13 78.00 25 15.17 435 165 3.38 / 224.01 2 3
7 13 45.04 25 15.18 379 144 3.52 / 224.15 2 4
8 8 0.08 175 15.14 296 784 4.31 / 224.94 2 3
Average= 4.17
(KJ/cycle)

Cycle 52 GMT 11/12/2021 19:47:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.40 28 15.10 472 200 0.20 / 216.47 2 3
2 12 1165.60 3 15.18 2094 95 0.29 / 216.56 2 3
3 7 2005.64 33 14.74 3161 1538 1.83 / 218.10 2 3
4 13 1469.40 25 14.79 2442 903 2.74 / 219.00 2 3
5 13 685.16 25 14.98 1351 506 3.24 / 219.51 2 4
6 13 94.60 25 15.16 470 178 3.42 / 219.69 2 2
7 13 26.84 25 15.17 356 135 3.55 / 219.82 2 2
8 8 0.04 175 15.15 305 809 4.36 / 220.63 2 7
Average= 4.16
(KJ/cycle)

Cycle 51 GMT 1/12/2021 22: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.00 28 15.12 483 204 0.20 / 212.13 2 3
2 12 1328.16 3 15.12 2335 106 0.31 / 212.23 2 3
3 7 2007.80 33 14.73 3151 1532 1.84 / 213.76 2 3
4 13 1480.76 25 14.78 2465 911 2.75 / 214.68 2 3
5 13 635.12 25 15.01 1276 479 3.23 / 215.15 2 3
6 13 124.00 25 15.16 511 194 3.43 / 215.35 2 3
7 13 39.88 25 15.17 367 139 3.56 / 215.49 2 3
8 8 0.00 175 15.14 295 782 4.35 / 216.27 2 6
Average= 4.16
(KJ/cycle)

Cycle 50 GMT 22/11/2021 0:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.88 28 15.12 474 201 0.20 / 207.92 2 3
2 12 1181.64 3 15.17 2127 97 0.30 / 208.02 2 3
3 7 2003.72 33 14.75 3156 1536 1.83 / 209.55 2 3
4 13 1477.56 25 14.79 2455 908 2.74 / 210.46 2 3
5 13 627.76 25 15.01 1262 474 3.21 / 210.94 2 3
6 13 120.40 25 15.16 505 191 3.41 / 211.13 2 4
7 8 0.12 175 15.16 300 796 4.20 / 211.92 2 3
Average= 4.16
(KJ/cycle)

Cycle 49 GMT 12/11/2021 2:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.96 28 15.12 454 192 0.19 / 203.74 2 3
2 12 1169.52 3 15.19 2103 96 0.29 / 203.84 2 3
3 7 2002.08 33 14.73 3150 1531 1.82 / 205.37 2 3
4 13 1455.32 25 14.81 2430 900 2.72 / 206.27 2 3
5 13 606.24 25 15.02 1228 461 3.18 / 206.73 2 3
6 13 102.76 25 15.17 480 182 3.36 / 206.91 2 3
7 8 0.00 175 15.16 304 807 4.17 / 207.72 2 2
Average= 4.15
(KJ/cycle)

Cycle 48 GMT 2/11/2021 4:30:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.48 28 15.13 467 198 0.20 / 199.61 2 3
2 12 1165.32 3 15.19 2105 96 0.29 / 199.71 2 2
3 7 2005.20 33 14.74 3157 1536 1.83 / 201.24 2 3
4 13 1405.28 25 14.81 2354 872 2.70 / 202.11 2 3
5 13 654.80 25 15.02 1301 489 3.19 / 202.60 2 4
6 13 79.80 25 15.17 440 167 3.36 / 202.77 2 4
7 8 -0.04 175 15.17 295 783 4.14 / 203.55 2 4
Average= 4.15
(KJ/cycle)

Cycle 47 GMT 23/10/2021 6:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.20 28 15.13 477 202 0.20 / 195.20 2 3
2 12 1156.28 3 15.20 2083 95 0.30 / 195.30 2 2
3 7 2005.96 33 14.75 3153 1535 1.83 / 196.83 2 3
4 13 1565.48 25 14.77 2572 950 2.78 / 197.78 2 3
5 13 771.52 25 14.98 1470 551 3.33 / 198.33 2 3
6 13 83.08 25 15.19 445 169 3.50 / 198.50 2 3
7 8 0.12 175 15.18 300 797 4.30 / 199.30 2 4
8 14 0.12 25 15.15 301 114 4.41 / 199.41 2 10
Average= 4.15
(KJ/cycle)

Cycle 46 GMT 13/10/2021 8:46: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.32 28 15.12 480 203 0.20 / 191.05 2 3
2 12 1168.60 3 15.19 2106 96 0.30 / 191.15 2 3
3 7 2005.56 34 14.73 3151 1578 1.88 / 192.73 2 3
4 13 1466.68 25 14.80 2438 902 2.78 / 193.63 2 3
5 13 546.68 25 15.05 1154 434 3.21 / 194.06 2 3
6 13 79.72 25 15.19 446 169 3.38 / 194.23 2 3
7 8 0.00 165 15.18 307 769 4.15 / 195.00 2 8
Average= 4.15
(KJ/cycle)

Cycle 45 GMT 3/10/2021 10:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.80 28 15.15 468 199 0.20 / 186.93 2 3
2 12 1322.72 3 15.14 2315 105 0.30 / 187.03 2 3
3 7 2002.76 33 14.76 3149 1534 1.84 / 188.57 2 3
4 13 1403.68 25 14.83 2356 873 2.71 / 189.44 2 4
5 13 646.08 25 15.03 1286 483 3.19 / 189.92 2 4
6 13 68.68 25 15.18 432 164 3.36 / 190.09 2 3
7 8 -0.08 165 15.18 304 761 4.12 / 190.85 2 3
Average= 4.15
(KJ/cycle)

Cycle 44 GMT 23/ 9/2021 12:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.32 28 15.15 467 198 0.20 / 182.77 2 3
2 12 1186.92 3 15.19 2119 97 0.29 / 182.86 2 3
3 7 2004.20 33 14.76 3150 1534 1.83 / 184.40 2 3
4 13 1460.24 25 14.82 2430 900 2.73 / 185.30 2 3
5 13 686.80 25 15.02 1344 505 3.23 / 185.80 2 4
6 13 82.36 25 15.20 449 171 3.40 / 185.97 2 2
7 8 0.00 165 15.19 302 757 4.16 / 186.73 2 5
Average= 4.15
(KJ/cycle)

Cycle 43 GMT 13/ 9/2021 14:57: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.48 28 15.15 478 203 0.20 / 178.57 2 3
2 12 1170.52 3 15.22 2103 96 0.30 / 178.66 2 2
3 7 2002.52 33 14.76 3152 1535 1.83 / 180.20 2 3
4 13 1482.76 25 14.82 2467 914 2.75 / 181.11 2 3
5 13 698.52 25 15.02 1369 514 3.26 / 181.62 2 4
6 13 83.44 25 15.20 457 174 3.44 / 181.80 2 3
7 8 0.08 165 15.19 307 769 4.21 / 182.57 2 3
Average= 4.15
(KJ/cycle)

Cycle 42 GMT 3/ 9/2021 17:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.84 28 15.15 471 200 0.20 / 174.43 2 3
2 12 1166.60 3 15.20 2105 96 0.30 / 174.53 2 2
3 7 2003.12 33 14.76 3151 1535 1.83 / 176.06 2 3
4 13 1461.52 25 14.83 2428 900 2.73 / 176.96 2 3
5 13 618.12 25 15.05 1252 471 3.20 / 177.43 2 3
6 13 67.80 25 15.21 427 162 3.36 / 177.60 2 3
7 8 0.00 165 15.20 305 765 4.13 / 178.36 2 5
Average= 4.15
(KJ/cycle)

Cycle 41 GMT 24/ 8/2021 19:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.12 28 15.16 471 200 0.20 / 170.07 2 2
2 12 1315.20 3 15.16 2312 105 0.31 / 170.17 2 3
3 7 2005.32 33 14.75 3148 1532 1.84 / 171.71 2 3
4 13 1415.72 41 14.79 2354 1427 3.26 / 173.13 2 3
5 13 152.48 41 15.18 555 345 3.61 / 173.48 2 3
6 8 0.00 165 15.19 301 754 4.36 / 174.23 2 3
Average= 4.15
(KJ/cycle)

Cycle 40 GMT 14/ 8/2021 21:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.36 28 15.14 482 204 0.20 / 165.72 2 3
2 12 1331.40 3 15.14 2359 107 0.31 / 165.83 2 3
3 7 2005.76 33 14.75 3146 1531 1.84 / 167.36 2 3
4 13 1427.04 41 14.78 2370 1436 3.28 / 168.80 2 3
5 13 105.32 41 15.20 482 300 3.58 / 169.10 2 3
6 8 -0.12 165 15.19 307 769 4.35 / 169.87 2 4
Average= 4.14
(KJ/cycle)

Cycle 39 GMT 5/ 8/2021 0:11: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.36 28 15.15 469 199 0.20 / 161.24 2 3
2 7 2004.88 36 14.74 3148 1670 1.87 / 162.91 2 3
3 13 1431.72 41 14.79 2386 1447 3.32 / 164.36 2 3
4 13 170.36 41 15.19 589 367 3.68 / 164.73 2 4
5 8 0.04 165 15.19 316 792 4.48 / 165.52 2 6
Average= 4.14
(KJ/cycle)

Cycle 38 GMT 26/ 7/2021 3: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.52 28 15.17 482 205 0.20 / 156.84 2 3
2 7 2005.28 36 14.75 3154 1675 1.88 / 158.52 2 3
3 13 1428.92 41 14.80 2381 1445 3.32 / 159.96 2 4
4 13 112.64 41 15.20 495 308 3.63 / 160.27 2 3
5 8 0.12 165 15.20 308 772 4.41 / 161.04 2 5
Average= 4.13
(KJ/cycle)

Cycle 37 GMT 16/ 7/2021 5:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.08 28 15.15 471 200 0.20 / 152.42 2 3
2 7 2005.56 36 14.75 3147 1671 1.87 / 154.10 2 3
3 13 1430.88 41 14.79 2375 1440 3.31 / 155.54 2 4
4 13 112.68 41 15.22 499 311 3.62 / 155.85 2 3
5 8 -0.04 165 15.20 316 793 4.41 / 156.64 2 4
Average= 4.12
(KJ/cycle)

Cycle 36 GMT 6/ 7/2021 8:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.72 28 15.15 476 202 0.20 / 147.99 2 2
2 7 2003.88 36 14.75 3140 1667 1.87 / 149.66 2 3
3 13 1415.08 41 14.79 2350 1425 3.29 / 151.08 2 4
4 13 171.64 41 15.17 589 366 3.66 / 151.45 2 3
5 8 -0.12 165 15.19 309 774 4.44 / 152.22 2 2
Average= 4.11
(KJ/cycle)

Cycle 35 GMT 26/ 6/2021 11:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.52 28 15.16 460 195 0.20 / 143.47 2 3
2 7 2004.64 36 14.74 3146 1669 1.86 / 145.14 2 3
3 13 1553.20 41 14.75 2542 1537 3.40 / 146.68 2 3
4 13 151.32 41 15.20 554 345 3.75 / 147.02 2 3
5 8 -0.08 165 15.20 305 765 4.51 / 147.79 2 3
Average= 4.11
(KJ/cycle)

Cycle 34 GMT 16/ 6/2021 14:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.44 28 15.15 480 204 0.20 / 139.22 2 3
2 7 1873.48 37 14.79 2975 1628 1.83 / 140.85 2 3
3 13 1316.60 41 14.84 2222 1352 3.18 / 142.20 2 3
4 13 120.28 41 15.22 507 316 3.50 / 142.51 2 3
5 8 0.04 165 15.22 304 763 4.26 / 143.28 2 3
Average= 4.09
(KJ/cycle)

Cycle 33 GMT 6/ 6/2021 14:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.68 28 15.17 472 200 0.20 / 134.74 2 3
2 7 2010.48 36 14.76 3153 1675 1.88 / 136.41 2 3
3 13 1429.80 41 14.79 2387 1447 3.32 / 137.86 2 4
4 13 182.04 41 15.18 609 379 3.70 / 138.24 2 3
5 8 0.04 165 15.21 308 773 4.48 / 139.01 2 2
Average= 4.09
(KJ/cycle)

Cycle 32 GMT 27/ 5/2021 17:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.56 28 15.18 458 195 0.19 / 130.29 2 3
2 7 2003.48 36 14.76 3149 1673 1.87 / 131.96 2 3
3 13 1418.12 41 14.81 2364 1435 3.30 / 133.40 2 3
4 13 159.40 41 15.19 568 354 3.66 / 133.75 2 4
5 8 0.00 165 15.20 313 785 4.44 / 134.54 2 4
Average= 4.08
(KJ/cycle)

Cycle 31 GMT 17/ 5/2021 20:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.00 28 15.18 475 202 0.20 / 125.86 2 3
2 7 2004.28 36 14.77 3148 1674 1.88 / 127.53 2 3
3 13 1420.68 41 14.81 2364 1435 3.31 / 128.97 2 4
4 13 178.92 41 15.20 596 371 3.68 / 129.34 2 3
5 8 -0.16 165 15.22 301 756 4.44 / 130.10 2 9
Average= 4.07
(KJ/cycle)

Cycle 30 GMT 7/ 5/2021 23:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.28 28 15.18 460 196 0.20 / 121.45 2 3
2 7 2010.68 36 14.76 3166 1682 1.88 / 123.13 2 3
3 13 1432.72 41 14.81 2386 1449 3.33 / 124.58 2 3
4 13 113.00 41 15.23 492 307 3.63 / 124.88 2 2
5 8 0.04 165 15.22 308 773 4.41 / 125.66 2 15
Average= 4.05
(KJ/cycle)

Cycle 29 GMT 28/ 4/2021 1:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.88 27 15.18 472 193 0.19 / 116.97 2 3
2 7 2010.84 36 14.76 3156 1677 1.87 / 118.64 2 3
3 13 1427.24 41 14.81 2382 1446 3.32 / 120.09 2 4
4 13 181.64 41 15.20 612 381 3.70 / 120.47 2 4
5 8 -0.08 165 15.22 310 779 4.48 / 121.25 2 6
Average= 4.04
(KJ/cycle)

Cycle 28 GMT 18/ 4/2021 4:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.56 27 15.20 462 190 0.19 / 112.58 2 3
2 7 2003.80 36 14.77 3147 1673 1.86 / 114.25 2 3
3 13 1423.04 41 14.81 2368 1438 3.30 / 115.69 2 3
4 13 111.40 41 15.24 489 306 3.61 / 116.00 2 2
5 8 0.00 165 15.23 309 777 4.38 / 116.77 2 12
Average= 4.03
(KJ/cycle)

Cycle 27 GMT 8/ 4/2021 7:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.76 27 15.18 484 198 0.20 / 108.16 2 3
2 7 2006.48 36 14.79 3157 1681 1.88 / 109.84 2 3
3 13 1401.24 41 14.84 2340 1424 3.30 / 111.27 2 3
4 13 165.64 41 15.23 578 361 3.66 / 111.63 2 4
5 8 0.04 165 15.24 304 764 4.43 / 112.39 2 3
Average= 4.01
(KJ/cycle)

Cycle 26 GMT 29/ 3/2021 10:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.44 27 15.19 465 191 0.19 / 103.71 2 3
2 7 2005.56 36 14.77 3157 1679 1.87 / 105.38 2 2
3 13 1410.60 41 14.83 2350 1429 3.30 / 106.81 2 3
4 13 157.76 41 15.21 571 356 3.65 / 107.17 2 3
5 8 -0.08 165 15.22 316 794 4.45 / 107.96 2 4
Average= 4.00
(KJ/cycle)

Cycle 25 GMT 19/ 3/2021 13: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.68 27 15.19 481 197 0.20 / 99.21 2 3
2 7 2007.60 36 14.78 3157 1680 1.88 / 100.89 2 3
3 13 1408.00 37 14.84 2352 1291 3.17 / 102.19 2 3
4 13 205.44 37 15.20 645 363 3.53 / 102.55 2 3
5 13 32.40 37 15.24 356 201 3.73 / 102.75 2 3
6 8 -0.04 165 15.22 305 766 4.50 / 103.51 2 5
Average= 3.98
(KJ/cycle)

Cycle 24 GMT 9/ 3/2021 15:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.92 27 15.17 481 197 0.20 / 94.66 2 3
2 7 2003.56 37 14.78 3155 1725 1.92 / 96.38 2 3
3 13 1405.28 37 14.84 2352 1291 3.21 / 97.67 2 4
4 13 190.60 37 15.22 625 352 3.57 / 98.03 2 3
5 13 26.20 37 15.25 358 202 3.77 / 98.23 2 3
6 8 0.00 165 15.23 314 789 4.56 / 99.02 2 4
Average= 3.96
(KJ/cycle)

Cycle 23 GMT 27/ 2/2021 18:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.44 27 15.18 485 199 0.20 / 90.11 2 3
2 7 2010.04 36 14.77 3168 1684 1.88 / 91.79 2 3
3 13 1421.64 37 14.82 2368 1298 3.18 / 93.09 2 3
4 13 223.72 37 15.20 673 378 3.56 / 93.47 2 3
5 13 32.28 37 15.26 362 204 3.76 / 93.67 2 2
6 8 -0.12 165 15.22 313 786 4.55 / 94.46 2 5
Average= 3.94
(KJ/cycle)

Cycle 22 GMT 17/ 2/2021 21:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.20 27 15.20 469 192 0.19 / 85.58 2 3
2 7 2004.16 36 14.77 3148 1674 1.87 / 87.25 2 3
3 13 1403.96 37 14.84 2350 1290 3.16 / 88.54 2 3
4 13 228.80 37 15.20 672 378 3.53 / 88.92 2 3
5 13 31.60 37 15.25 367 207 3.74 / 89.13 2 3
6 8 0.04 165 15.22 312 784 4.53 / 89.91 2 4
Average= 3.91
(KJ/cycle)

Cycle 21 GMT 7/ 2/2021 23:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.76 27 15.18 483 198 0.20 / 81.03 2 3
2 7 2011.76 37 14.77 3164 1729 1.93 / 82.76 2 3
3 13 1409.28 37 14.86 2357 1296 3.22 / 84.05 2 3
4 13 214.88 37 15.22 654 368 3.59 / 84.42 2 3
5 13 14.76 37 15.26 332 187 3.78 / 84.61 2 3
6 8 -0.08 165 15.23 308 774 4.55 / 85.38 2 4
Average= 3.88
(KJ/cycle)

Cycle 20 GMT 29/ 1/2021 2:41: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.88 27 15.20 482 198 0.20 / 76.48 2 3
2 7 2009.40 36 14.79 3163 1684 1.88 / 78.16 2 3
3 13 1428.76 37 14.84 2385 1310 3.19 / 79.47 2 4
4 13 235.76 37 15.20 692 389 3.58 / 79.86 2 3
5 13 19.24 37 15.25 340 192 3.77 / 80.05 2 3
6 8 -0.08 165 15.22 311 781 4.55 / 80.83 2 7
Average= 3.85
(KJ/cycle)

Cycle 19 GMT 19/ 1/2021 5:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.00 27 15.22 478 196 0.20 / 72.35 2 3
2 7 2009.44 27 14.89 3167 1273 1.47 / 73.62 2 3
3 13 1605.20 23 14.85 2628 898 2.37 / 74.52 2 3
4 13 996.96 23 14.99 1791 617 2.98 / 75.14 2 5
5 13 200.88 23 15.23 639 224 3.21 / 75.36 2 3
6 13 65.32 23 15.26 421 148 3.36 / 75.51 2 3
7 8 0.08 165 15.25 306 770 4.13 / 76.28 2 7
Average= 3.81
(KJ/cycle)

Cycle 18 GMT 9/ 1/2021 7:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.88 27 15.22 467 192 0.19 / 68.18 2 3
2 7 2009.76 27 14.91 3167 1275 1.47 / 69.46 2 3
3 13 1745.12 23 14.83 2813 959 2.43 / 70.42 2 3
4 13 969.88 23 15.01 1759 607 3.03 / 71.03 2 3
5 13 195.20 23 15.25 632 222 3.26 / 71.25 2 3
6 13 70.84 23 15.27 421 148 3.40 / 71.40 2 3
7 8 -0.08 165 15.26 300 755 4.16 / 72.15 2 4
Average= 3.80
(KJ/cycle)

Cycle 17 GMT 30/12/2020 9:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.44 27 15.21 493 202 0.20 / 64.19 2 3
2 7 2007.12 30 14.86 3155 1406 1.61 / 65.59 2 3
3 13 1586.60 18 14.89 2604 698 2.31 / 66.29 2 3
4 13 873.84 18 15.06 1623 440 2.75 / 66.73 2 4
5 13 436.24 18 15.18 987 270 3.02 / 67.00 2 3
6 13 112.96 18 15.27 492 135 3.15 / 67.14 2 3
7 13 67.40 18 15.27 409 112 3.26 / 67.25 2 3
8 8 0.12 165 15.26 296 745 4.01 / 67.99 2 4
Average= 3.78
(KJ/cycle)

Cycle 16 GMT 20/12/2020 11:59: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.40 27 15.21 495 203 0.20 / 60.11 2 3
2 7 2002.92 31 14.84 3160 1454 1.66 / 61.56 2 3
3 13 1481.96 18 14.92 2474 664 2.32 / 62.22 2 3
4 13 919.84 18 15.03 1684 456 2.78 / 62.68 2 3
5 13 474.92 18 15.16 1053 287 3.06 / 62.97 2 3
6 13 110.12 18 15.26 490 135 3.20 / 63.10 2 3
7 13 62.08 18 15.26 416 114 3.31 / 63.22 2 3
8 8 0.04 165 15.25 305 767 4.08 / 63.98 2 6
Average= 3.76
(KJ/cycle)

Cycle 15 GMT 10/12/2020 13:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 122.20 27 15.23 493 203 0.20 / 56.08 2 3
2 7 2008.16 30 14.86 3157 1407 1.61 / 57.48 2 3
3 13 1598.24 18 14.89 2629 705 2.31 / 58.19 2 3
4 13 1012.44 18 15.02 1823 493 2.81 / 58.68 2 3
5 13 284.20 18 15.22 763 209 3.02 / 58.89 2 3
6 13 111.00 18 15.27 489 134 3.15 / 59.02 2 3
7 13 63.16 18 15.27 412 113 3.26 / 59.14 2 3
8 8 -0.04 165 15.26 304 765 4.03 / 59.90 2 5
Average= 3.74
(KJ/cycle)

Cycle 14 GMT 30/11/2020 16: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.40 27 15.23 471 194 0.19 / 52.15 2 3
2 7 2010.72 30 14.86 3165 1411 1.60 / 53.56 2 3
3 13 1467.76 20 14.92 2443 729 2.33 / 54.29 2 3
4 13 879.16 20 15.07 1632 492 2.83 / 54.78 2 4
5 13 168.80 20 15.27 587 179 3.00 / 54.96 2 3
6 13 112.08 20 15.28 491 150 3.15 / 55.11 2 3
7 8 0.04 165 15.27 304 766 3.92 / 55.87 2 5
Average= 3.72
(KJ/cycle)

Cycle 13 GMT 20/11/2020 18: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.72 27 15.23 483 199 0.20 / 48.10 2 3
2 7 2008.80 31 14.87 3169 1461 1.66 / 49.56 2 3
3 13 1597.72 20 14.89 2624 781 2.44 / 50.34 2 3
4 13 871.16 20 15.06 1620 488 2.93 / 50.83 2 3
5 13 262.12 20 15.24 734 224 3.15 / 51.05 2 3
6 13 110.68 20 15.27 485 148 3.30 / 51.20 2 3
7 8 0.00 165 15.27 298 751 4.05 / 51.95 2 4
Average= 3.71
(KJ/cycle)

Cycle 12 GMT 10/11/2020 20:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.20 27 15.23 461 190 0.19 / 44.15 2 3
2 7 2009.96 31 14.85 3168 1458 1.65 / 45.61 2 3
3 13 1464.80 20 14.92 2444 729 2.38 / 46.34 2 3
4 13 870.64 20 15.05 1610 485 2.86 / 46.82 2 4
5 13 165.76 20 15.26 574 175 3.04 / 47.00 2 3
6 13 108.40 20 15.26 478 146 3.18 / 47.15 2 3
7 8 0.04 165 15.25 300 755 3.94 / 47.90 2 4
Average= 3.68
(KJ/cycle)

Cycle 11 GMT 31/10/2020 22:17: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.28 27 15.22 487 200 0.20 / 40.14 2 3
2 7 2005.16 33 14.86 3136 1538 1.74 / 41.68 2 3
3 13 1444.88 20 14.95 2412 721 2.46 / 42.40 2 3
4 13 851.64 20 15.08 1589 479 2.94 / 42.88 2 3
5 13 228.56 20 15.25 675 206 3.14 / 43.09 2 2
6 13 95.20 20 15.28 452 138 3.28 / 43.23 2 3
7 8 0.24 165 15.28 292 736 4.02 / 43.96 2 5
Average= 3.66
(KJ/cycle)

Cycle 10 GMT 22/10/2020 0:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.72 27 15.23 465 191 0.19 / 36.19 2 3
2 7 2009.28 33 14.85 3159 1548 1.74 / 37.74 2 3
3 13 1438.24 20 14.94 2408 720 2.46 / 38.46 2 3
4 13 705.80 20 15.11 1382 418 2.88 / 38.88 2 3
5 13 150.36 20 15.28 554 169 3.05 / 39.05 2 3
6 13 93.72 20 15.28 459 140 3.19 / 39.19 2 3
7 8 0.04 165 15.27 300 756 3.94 / 39.94 2 6
Average= 3.63
(KJ/cycle)

Cycle 9 GMT 12/10/2020 2:30: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.20 27 15.24 474 195 0.20 / 32.26 2 3
2 7 2003.08 30 14.89 3146 1405 1.60 / 33.67 2 3
3 13 1586.32 20 14.91 2597 774 2.37 / 34.44 2 4
4 13 842.08 20 15.08 1580 477 2.85 / 34.92 2 3
5 13 234.12 20 15.26 694 212 3.06 / 35.13 2 3
6 13 91.76 20 15.28 462 141 3.20 / 35.27 2 3
7 8 0.20 165 15.29 290 732 3.94 / 36.00 2 4
Average= 3.60
(KJ/cycle)

Cycle 8 GMT 2/10/2020 4:38:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.16 26 15.24 481 191 0.19 / 28.26 2 3
2 3 1020.56 1 15.28 1889 29 0.22 / 28.29 2 3
3 7 2005.80 30 14.88 3151 1407 1.63 / 29.70 2 3
4 13 1580.08 20 14.92 2604 777 2.40 / 30.47 2 4
5 13 835.96 20 15.09 1568 473 2.88 / 30.95 2 3
6 13 237.88 20 15.26 696 212 3.09 / 31.16 2 3
7 13 92.48 20 15.30 466 143 3.23 / 31.30 2 3
8 8 0.04 165 15.28 304 766 4.00 / 32.07 2 7
Average= 3.56
(KJ/cycle)

Cycle 7 GMT 22/ 9/2020 6:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.00 26 15.25 478 190 0.19 / 24.27 2 3
2 7 2006.92 30 14.89 3158 1411 1.60 / 25.68 2 3
3 13 1586.44 20 14.94 2611 780 2.38 / 26.46 2 3
4 13 851.36 20 15.10 1590 480 2.86 / 26.94 2 3
5 13 237.48 20 15.27 701 214 3.07 / 27.16 2 3
6 13 92.96 20 15.30 464 142 3.22 / 27.30 2 3
7 8 0.04 165 15.29 305 769 3.99 / 28.07 2 4
Average= 3.51
(KJ/cycle)

Cycle 6 GMT 12/ 9/2020 9: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.08 25 15.24 476 181 0.18 / 20.23 2 3
2 3 1056.28 2 15.23 1946 59 0.24 / 20.29 2 3
3 7 2003.20 38 14.84 3147 1775 2.02 / 22.07 2 3
4 13 1277.72 18 14.99 2188 590 2.61 / 22.66 2 3
5 13 696.00 18 15.14 1368 373 2.98 / 23.03 2 4
6 13 136.52 18 15.31 535 147 3.13 / 23.18 2 3
7 13 76.04 18 15.30 448 123 3.25 / 23.30 2 2
8 8 -0.04 165 15.29 310 782 4.03 / 24.08 2 4
Average= 3.44
(KJ/cycle)

Cycle 5 GMT 2/ 9/2020 11: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.28 26 15.24 473 187 0.19 / 16.28 2 3
2 3 961.20 -1 15.58 0 0 0.00 / 16.28 2 3
3 7 2004.04 38 14.82 3142 1769 1.96 / 18.05 2 3
4 13 1259.44 18 15.01 2160 584 2.54 / 18.63 2 3
5 13 694.96 18 15.13 1374 374 2.91 / 19.00 2 3
6 13 130.32 18 15.29 534 147 3.06 / 19.15 2 3
7 13 72.96 18 15.30 448 123 3.19 / 19.27 2 3
8 8 0.08 165 15.29 308 777 3.96 / 20.05 2 5
Average= 3.34
(KJ/cycle)

Cycle 4 GMT 23/ 8/2020 12:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.52 25 15.25 481 183 0.18 / 12.77 2 3
2 3 1019.92 1 15.30 1891 29 0.21 / 12.79 2 3
3 7 1523.68 38 15.01 2497 1424 1.64 / 14.22 2 4
4 13 1117.60 18 15.07 1960 532 2.17 / 14.75 2 3
5 13 532.60 18 15.21 1130 309 2.48 / 15.06 2 3
6 13 110.76 18 15.31 504 139 2.62 / 15.20 2 2
7 13 66.44 18 15.31 431 119 2.74 / 15.32 2 3
8 8 0.16 165 15.29 306 772 3.51 / 16.09 2 4
Average= 3.22
(KJ/cycle)

Cycle 3 GMT 22/ 8/2020 12:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.36 23 15.23 464 163 0.16 / 9.21 2 3
2 3 1053.12 2 15.21 1941 59 0.22 / 9.27 2 3
3 7 1524.68 39 14.98 2491 1455 1.68 / 10.73 2 3
4 13 1111.32 18 15.07 1940 526 2.20 / 11.25 2 3
5 13 532.52 18 15.19 1122 307 2.51 / 11.56 2 3
6 13 112.64 18 15.30 500 138 2.65 / 11.70 2 3
7 13 61.52 18 15.29 421 116 2.76 / 11.81 2 3
8 8 0.04 165 15.28 305 769 3.53 / 12.58 2 4
Average= 3.15
(KJ/cycle)

Cycle 2 GMT 21/ 8/2020 12:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.16 28 15.25 466 199 0.20 / 4.99 2 3
2 3 875.44 -2 15.58 0 0 0.00 / 4.99 2 3
3 3 936.00 -1 15.62 0 0 0.00 / 4.99 2 3
4 7 1510.56 74 14.91 2454 2708 2.91 / 7.69 2 3
5 13 117.00 18 15.31 503 139 3.05 / 7.83 2 2
6 13 71.12 18 15.31 432 119 3.16 / 7.95 2 2
7 8 0.12 165 15.29 302 762 3.93 / 8.71 2 2
8 14 0.12 75 15.26 295 338 4.26 / 9.05 2 9
Average= 3.02
(KJ/cycle)

Cycle 1 GMT 20/ 8/2020 13:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.76 24 15.48 407 151 0.15 / 1.72 3 3
2 7 1008.40 74 15.09 1754 1959 2.11 / 3.68 2 3
3 8 0.04 165 15.33 302 764 2.87 / 4.44 2 5
4 14 0.04 75 15.30 301 345 3.22 / 4.79 2 5
Average= 2.39
(KJ/cycle)

Cycle 0 GMT 20/ 8/2020 2:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 83.84 24 15.61 392 147 0.15 / 0.15 3 3
2 7 99.76 74 15.59 413 476 0.62 / 0.62 3 3
3 8 0.12 240 15.54 253 944 1.57 / 1.57 3 10
Average= 1.57
(KJ/cycle)