SIO Argo Site:
Pump Diagnostics Page   



Serial= 8725 WMO= 1902038

Return

←PreviousNext→

Cycle 219 GMT 17/12/2024 9: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.72 35 15.03 449 236 0.24 / 901.26 2 2
2 12 1179.40 4 15.23 2028 124 0.36 / 901.39 2 2
3 7 2005.12 33 14.80 2998 1464 1.82 / 902.85 2 3
4 13 1507.64 21 14.81 2379 740 2.56 / 903.59 2 4
5 13 990.84 21 14.86 1697 530 3.09 / 904.12 2 4
6 13 156.36 21 15.07 541 171 3.26 / 904.29 2 3
7 13 31.20 21 15.10 359 114 3.38 / 904.40 2 3
8 8 0.04 175 15.07 304 802 4.18 / 905.21 2 7
Average= 4.11
(KJ/cycle)

Cycle 218 GMT 7/12/2024 11: 6: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.24 35 15.04 453 238 0.24 / 897.10 2 2
2 12 1193.16 4 15.23 2040 124 0.36 / 897.23 2 2
3 7 2005.16 32 14.81 3002 1423 1.79 / 898.65 2 3
4 13 1522.44 21 14.81 2405 748 2.53 / 899.40 2 3
5 13 1001.76 21 14.86 1726 539 3.07 / 899.94 2 3
6 13 159.80 21 15.07 554 175 3.25 / 900.11 2 3
7 13 29.52 21 15.09 358 113 3.36 / 900.23 2 3
8 8 0.00 175 15.06 304 801 4.16 / 901.03 2 7
Average= 4.11
(KJ/cycle)

Cycle 217 GMT 27/11/2024 13: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.72 35 15.03 460 242 0.24 / 893.04 2 2
2 12 1180.12 4 15.23 2032 124 0.37 / 893.16 2 2
3 7 2002.48 33 14.80 2998 1464 1.83 / 894.62 2 4
4 13 1515.20 21 14.81 2396 745 2.58 / 895.37 2 4
5 13 992.52 21 14.86 1710 534 3.11 / 895.90 2 5
6 13 153.56 21 15.07 526 166 3.28 / 896.07 2 3
7 8 0.08 175 15.08 301 794 4.07 / 896.86 2 5
Average= 4.11
(KJ/cycle)

Cycle 216 GMT 17/11/2024 15: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.40 35 15.03 453 238 0.24 / 888.90 2 2
2 12 1182.60 4 15.24 2027 124 0.36 / 889.02 2 2
3 7 2005.88 33 14.80 3005 1468 1.83 / 890.49 2 3
4 13 1517.44 21 14.81 2407 749 2.58 / 891.24 2 4
5 13 998.40 21 14.85 1721 537 3.11 / 891.78 2 4
6 13 275.76 21 15.04 700 221 3.34 / 892.00 2 3
7 8 0.08 175 15.07 302 796 4.13 / 892.79 2 7
Average= 4.11
(KJ/cycle)

Cycle 215 GMT 7/11/2024 17: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.68 35 15.04 438 231 0.23 / 884.83 2 2
2 12 1175.60 4 15.24 2000 122 0.35 / 884.96 2 2
3 7 2001.64 32 14.82 3000 1423 1.78 / 886.38 2 4
4 13 1500.40 21 14.82 2375 739 2.51 / 887.12 2 4
5 13 978.24 21 14.87 1687 527 3.04 / 887.64 2 3
6 13 271.76 21 15.04 695 220 3.26 / 887.86 2 3
7 8 0.20 175 15.07 303 799 4.06 / 888.66 2 10
Average= 4.11
(KJ/cycle)

Cycle 214 GMT 28/10/2024 19:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.00 35 15.03 454 239 0.24 / 880.84 2 2
2 12 1185.16 4 15.24 2036 124 0.36 / 880.96 2 2
3 7 2002.08 32 14.80 3005 1423 1.79 / 882.39 2 4
4 13 1506.80 21 14.81 2384 741 2.53 / 883.13 2 3
5 13 976.64 21 14.86 1684 526 3.05 / 883.65 2 4
6 13 147.68 21 15.08 514 163 3.22 / 883.82 2 3
7 8 0.04 175 15.08 298 786 4.00 / 884.60 2 9
Average= 4.11
(KJ/cycle)

Cycle 213 GMT 18/10/2024 21: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.12 35 15.03 457 240 0.24 / 876.80 2 2
2 12 1189.48 4 15.24 2044 125 0.37 / 876.93 2 2
3 7 2002.32 32 14.81 3005 1424 1.79 / 878.35 2 3
4 13 1527.68 21 14.81 2416 751 2.54 / 879.10 2 3
5 13 1021.08 21 14.86 1740 543 3.08 / 879.65 2 4
6 13 168.88 21 15.07 543 172 3.26 / 879.82 2 3
7 8 0.00 175 15.07 297 783 4.04 / 880.60 2 9
Average= 4.11
(KJ/cycle)

Cycle 212 GMT 8/10/2024 23: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.44 35 15.02 454 239 0.24 / 872.67 2 2
2 12 1187.76 4 15.24 2022 123 0.36 / 872.79 2 2
3 7 2002.84 32 14.82 3004 1425 1.79 / 874.22 2 3
4 13 1665.28 21 14.79 2584 803 2.59 / 875.02 2 4
5 13 981.68 21 14.87 1684 526 3.11 / 875.54 2 4
6 13 288.00 21 15.04 718 227 3.34 / 875.77 2 3
7 8 0.16 175 15.07 300 791 4.13 / 876.56 2 7
Average= 4.12
(KJ/cycle)

Cycle 211 GMT 29/ 9/2024 1: 6:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.88 35 15.02 464 244 0.24 / 868.55 2 2
2 12 1175.16 4 15.24 2009 122 0.37 / 868.67 2 2
3 7 2006.64 33 14.82 3003 1469 1.84 / 870.14 2 3
4 13 1509.08 21 14.82 2388 743 2.58 / 870.88 2 3
5 13 989.40 21 14.87 1695 529 3.11 / 871.41 2 4
6 13 272.00 21 15.04 696 220 3.33 / 871.63 2 3
7 8 0.00 175 15.07 302 796 4.12 / 872.43 2 10
Average= 4.12
(KJ/cycle)

Cycle 210 GMT 19/ 9/2024 3:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.88 35 15.03 462 243 0.24 / 864.47 2 2
2 12 1167.48 4 15.26 1961 120 0.36 / 864.59 2 2
3 7 2001.76 32 14.82 3001 1423 1.79 / 866.02 2 3
4 13 1510.60 21 14.82 2380 741 2.53 / 866.76 2 3
5 13 990.88 21 14.87 1695 529 3.06 / 867.29 2 4
6 13 286.00 21 15.03 727 229 3.29 / 867.52 2 3
7 8 0.00 175 15.07 299 789 4.07 / 868.31 2 8
Average= 4.12
(KJ/cycle)

Cycle 209 GMT 9/ 9/2024 5:14: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.52 35 15.02 453 238 0.24 / 860.35 2 2
2 12 1182.52 4 15.25 1997 122 0.36 / 860.47 2 2
3 7 2007.20 32 14.82 2991 1418 1.78 / 861.89 2 3
4 13 1671.76 21 14.80 2590 805 2.58 / 862.69 2 3
5 13 964.92 21 14.88 1671 522 3.11 / 863.22 2 4
6 13 253.76 21 15.04 677 214 3.32 / 863.43 2 3
7 8 0.04 175 15.07 304 802 4.12 / 864.23 2 7
Average= 4.12
(KJ/cycle)

Cycle 208 GMT 30/ 8/2024 7:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.44 35 15.02 455 239 0.24 / 856.06 2 2
2 12 1168.76 4 15.26 1969 120 0.36 / 856.18 2 2
3 7 2003.20 32 14.82 2996 1421 1.78 / 857.60 2 3
4 13 1662.76 21 14.79 2580 801 2.58 / 858.40 2 4
5 13 956.64 21 14.88 1648 515 3.10 / 858.92 2 4
6 13 262.44 21 15.04 679 214 3.31 / 859.13 2 3
7 13 19.40 21 15.09 331 105 3.42 / 859.24 2 3
8 8 0.00 175 15.06 297 783 4.20 / 860.02 2 6
9 14 0.00 20 15.03 298 90 4.29 / 860.11 2 9
Average= 4.12
(KJ/cycle)

Cycle 207 GMT 20/ 8/2024 8:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.60 35 15.01 453 238 0.24 / 851.98 2 2
2 12 1186.48 4 15.24 2025 123 0.36 / 852.10 2 2
3 7 2004.52 33 14.80 3007 1469 1.83 / 853.57 2 3
4 13 1492.68 21 14.81 2371 737 2.57 / 854.31 2 4
5 13 971.80 21 14.87 1675 523 3.09 / 854.83 2 3
6 13 246.12 21 15.04 657 208 3.30 / 855.04 2 3
7 8 0.20 175 15.06 298 785 4.08 / 855.82 2 6
Average= 4.11
(KJ/cycle)

Cycle 206 GMT 10/ 8/2024 10:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.12 35 15.01 458 241 0.24 / 847.89 2 2
2 12 1175.72 4 15.25 1997 122 0.36 / 848.01 2 2
3 7 2004.76 33 14.80 2999 1465 1.83 / 849.48 2 3
4 13 1509.84 21 14.81 2391 744 2.57 / 850.22 2 4
5 13 983.68 21 14.87 1688 527 3.10 / 850.75 2 4
6 13 261.96 21 15.03 675 213 3.31 / 850.96 2 3
7 8 0.12 175 15.05 295 777 4.09 / 851.74 2 6
Average= 4.11
(KJ/cycle)

Cycle 205 GMT 31/ 7/2024 12:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.72 35 15.01 440 231 0.23 / 843.68 2 2
2 12 1172.32 4 15.27 1997 122 0.35 / 843.80 2 2
3 7 2005.24 32 14.82 3003 1424 1.78 / 845.23 2 3
4 13 1532.24 21 14.82 2427 755 2.53 / 845.98 2 4
5 13 1021.48 21 14.86 1743 544 3.08 / 846.53 2 3
6 13 306.88 21 15.02 749 236 3.31 / 846.76 2 3
7 13 29.68 21 15.08 344 109 3.42 / 846.87 2 3
8 8 -0.08 175 15.05 296 780 4.20 / 847.65 2 7
Average= 4.11
(KJ/cycle)

Cycle 204 GMT 21/ 7/2024 14:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.16 35 14.99 434 228 0.23 / 839.55 2 2
2 12 1173.48 4 15.25 2014 123 0.35 / 839.67 2 2
3 7 2007.16 32 14.82 2985 1416 1.77 / 841.09 2 3
4 13 1515.04 21 14.82 2387 743 2.51 / 841.83 2 3
5 13 987.04 21 14.88 1699 531 3.04 / 842.36 2 4
6 13 265.52 21 15.03 681 215 3.25 / 842.58 2 3
7 13 26.92 21 15.08 333 105 3.36 / 842.68 2 3
8 8 0.04 175 15.05 291 766 4.13 / 843.45 2 6
Average= 4.11
(KJ/cycle)

Cycle 203 GMT 11/ 7/2024 16:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.08 34 15.02 441 225 0.23 / 835.37 2 2
2 3 1021.80 1 15.24 1773 27 0.25 / 835.39 2 2
3 12 1177.16 4 15.26 2005 122 0.37 / 835.52 2 2
4 7 2006.96 32 14.82 3012 1428 1.80 / 836.94 2 3
5 13 1519.52 21 14.81 2402 747 2.55 / 837.69 2 3
6 13 998.48 21 14.87 1717 536 3.09 / 838.23 2 3
7 13 277.64 21 15.01 706 223 3.31 / 838.45 2 3
8 13 29.40 21 15.06 341 108 3.42 / 838.56 2 3
9 8 0.08 175 15.03 291 765 4.18 / 839.32 2 7
Average= 4.11
(KJ/cycle)

Cycle 202 GMT 1/ 7/2024 18:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.88 34 15.02 437 223 0.22 / 831.16 2 2
2 12 1199.48 4 15.28 2016 123 0.35 / 831.29 2 2
3 7 2002.96 33 14.83 2991 1464 1.81 / 832.75 2 3
4 13 1653.84 21 14.81 2569 799 2.61 / 833.55 2 4
5 13 938.48 21 14.91 1613 505 3.11 / 834.05 2 5
6 13 252.80 21 15.05 647 204 3.32 / 834.26 2 3
7 13 60.16 21 15.09 378 120 3.44 / 834.38 2 3
8 8 0.04 175 15.06 289 762 4.20 / 835.14 2 6
Average= 4.11
(KJ/cycle)

Cycle 201 GMT 21/ 6/2024 20: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.52 34 15.02 432 221 0.22 / 827.01 2 2
2 12 1181.56 4 15.26 2016 123 0.34 / 827.14 2 2
3 7 2003.16 32 14.83 3007 1427 1.77 / 828.56 2 3
4 13 1516.32 21 14.82 2395 745 2.52 / 829.31 2 4
5 13 991.04 21 14.88 1693 529 3.05 / 829.84 2 4
6 13 258.92 21 15.04 669 211 3.26 / 830.05 2 3
7 13 63.56 21 15.08 389 123 3.38 / 830.17 2 3
8 8 -0.04 175 15.06 291 767 4.15 / 830.94 2 7
Average= 4.11
(KJ/cycle)

Cycle 200 GMT 11/ 6/2024 21:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.68 34 15.03 428 219 0.22 / 822.74 2 2
2 12 1176.12 4 15.26 2020 123 0.34 / 822.87 2 2
3 7 2005.16 33 14.82 3014 1474 1.82 / 824.34 2 3
4 13 1510.24 21 14.83 2397 746 2.56 / 825.09 2 3
5 13 971.52 21 14.88 1671 522 3.08 / 825.61 2 4
6 13 259.72 21 15.04 668 211 3.30 / 825.82 2 3
7 13 70.00 21 15.08 396 125 3.42 / 825.95 2 3
8 8 0.16 175 15.06 288 759 4.18 / 826.71 2 7
9 14 0.16 20 15.04 292 88 4.27 / 826.79 2 6
Average= 4.11
(KJ/cycle)

Cycle 199 GMT 1/ 6/2024 23:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.92 34 15.03 462 236 0.24 / 818.58 2 2
2 12 1177.44 4 15.25 2025 124 0.36 / 818.70 2 2
3 7 2002.88 32 14.83 3021 1434 1.79 / 820.13 2 3
4 13 1496.88 21 14.83 2387 743 2.54 / 820.88 2 4
5 13 987.64 21 14.88 1697 530 3.07 / 821.41 2 4
6 13 292.00 21 15.04 716 226 3.29 / 821.63 2 3
7 13 84.28 21 15.08 419 133 3.43 / 821.77 2 3
8 8 -0.04 175 15.07 288 760 4.19 / 822.53 2 7
Average= 4.11
(KJ/cycle)

Cycle 198 GMT 23/ 5/2024 1:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.16 34 15.04 438 224 0.22 / 814.39 2 2
2 3 1023.44 1 15.25 1788 27 0.25 / 814.42 2 2
3 12 1176.88 4 15.25 1987 121 0.37 / 814.54 2 2
4 7 1947.96 32 14.83 2935 1393 1.77 / 815.94 2 4
5 13 1612.08 21 14.82 2536 789 2.55 / 816.72 2 3
6 13 932.96 21 14.90 1622 508 3.06 / 817.23 2 4
7 13 231.60 21 15.05 635 201 3.26 / 817.43 2 3
8 13 57.68 21 15.09 384 122 3.38 / 817.55 2 3
9 8 0.12 175 15.07 298 786 4.17 / 818.34 2 6
Average= 4.11
(KJ/cycle)

Cycle 197 GMT 13/ 5/2024 0:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.16 34 15.05 434 222 0.22 / 810.39 2 2
2 12 1166.92 4 15.25 2012 123 0.34 / 810.51 2 2
3 7 1783.52 32 14.89 2736 1304 1.65 / 811.82 2 5
4 13 1477.76 21 14.88 2352 735 2.38 / 812.55 2 4
5 13 961.80 21 14.92 1669 523 2.91 / 813.07 2 4
6 13 213.20 21 15.08 614 194 3.10 / 813.27 2 3
7 13 49.56 21 15.11 378 120 3.22 / 813.39 2 3
8 8 -0.12 175 15.08 296 781 4.00 / 814.17 2 7
Average= 4.11
(KJ/cycle)

Cycle 196 GMT 3/ 5/2024 0:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.48 34 15.02 439 224 0.22 / 806.32 2 2
2 12 1181.00 4 15.25 2034 124 0.35 / 806.44 2 2
3 7 1880.24 33 14.85 2858 1401 1.75 / 807.84 2 6
4 13 1553.44 21 14.84 2446 762 2.51 / 808.61 2 5
5 13 862.84 21 14.93 1523 478 2.99 / 809.08 2 4
6 13 179.20 21 15.08 569 180 3.17 / 809.26 2 3
7 13 50.32 21 15.10 376 119 3.29 / 809.38 2 3
8 8 0.12 175 15.08 298 786 4.07 / 810.17 2 7
Average= 4.11
(KJ/cycle)

Cycle 195 GMT 23/ 4/2024 0: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.24 34 15.03 448 229 0.23 / 802.13 2 2
2 12 1161.28 4 15.26 1993 122 0.35 / 802.25 2 2
3 7 2006.76 33 14.81 3013 1473 1.82 / 803.73 2 3
4 13 1481.48 21 14.84 2367 738 2.56 / 804.46 2 3
5 13 975.52 21 14.88 1687 527 3.09 / 804.99 2 4
6 13 250.28 21 15.05 667 211 3.30 / 805.20 2 3
7 13 28.84 21 15.09 344 109 3.41 / 805.31 2 3
8 8 0.12 175 15.06 297 783 4.19 / 806.09 2 7
Average= 4.11
(KJ/cycle)

Cycle 194 GMT 13/ 4/2024 1: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.16 34 15.01 458 234 0.23 / 797.91 2 2
2 12 1187.24 4 15.26 2039 124 0.36 / 798.04 2 2
3 7 2008.96 32 14.83 3014 1430 1.79 / 799.47 2 3
4 13 1539.88 21 14.82 2431 757 2.55 / 800.23 2 3
5 13 1001.92 21 14.88 1722 538 3.08 / 800.76 2 4
6 13 291.24 21 15.04 722 228 3.31 / 800.99 2 3
7 13 58.56 21 15.09 388 123 3.43 / 801.12 2 3
8 8 -0.08 175 15.07 299 789 4.22 / 801.90 2 7
Average= 4.11
(KJ/cycle)

Cycle 193 GMT 3/ 4/2024 3: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.60 33 15.08 447 222 0.22 / 793.76 2 2
2 3 1018.04 1 15.26 1813 28 0.25 / 793.79 2 2
3 12 1186.40 4 15.28 2013 123 0.37 / 793.91 2 2
4 7 2017.28 32 14.83 3025 1436 1.81 / 795.34 2 4
5 13 1534.16 21 14.83 2418 753 2.56 / 796.10 2 3
6 13 864.72 21 14.92 1528 479 3.04 / 796.58 2 3
7 13 184.44 21 15.06 569 180 3.22 / 796.76 2 3
8 13 50.28 21 15.08 385 122 3.34 / 796.88 2 3
9 8 -0.08 175 15.05 305 803 4.15 / 797.68 2 5
Average= 4.11
(KJ/cycle)

Cycle 192 GMT 24/ 3/2024 4:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.60 34 15.03 450 230 0.23 / 789.57 2 2
2 12 1187.48 4 15.25 2045 125 0.35 / 789.69 2 2
3 7 2003.24 32 14.84 3000 1425 1.78 / 791.12 2 3
4 13 1496.20 21 14.85 2375 741 2.52 / 791.86 2 5
5 13 978.12 21 14.90 1691 529 3.05 / 792.39 2 5
6 13 145.08 21 15.11 515 163 3.21 / 792.55 2 3
7 13 55.08 21 15.12 382 121 3.33 / 792.67 2 3
8 8 0.28 175 15.10 294 777 4.11 / 793.45 2 5
9 14 0.28 20 15.08 293 88 4.20 / 793.54 2 6
Average= 4.11
(KJ/cycle)

Cycle 191 GMT 14/ 3/2024 6:19: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.20 34 15.08 433 222 0.22 / 785.50 2 2
2 12 1166.48 4 15.24 2026 124 0.35 / 785.62 2 2
3 7 2004.96 32 14.81 3015 1429 1.77 / 787.05 2 3
4 13 1382.48 21 14.85 2231 696 2.47 / 787.74 2 3
5 13 889.68 21 14.89 1580 494 2.96 / 788.24 2 4
6 13 163.84 21 15.07 557 176 3.14 / 788.41 2 3
7 13 38.08 21 15.09 371 118 3.26 / 788.53 2 3
8 8 -0.08 175 15.06 305 804 4.06 / 789.34 2 9
Average= 4.11
(KJ/cycle)

Cycle 190 GMT 4/ 3/2024 7:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.92 34 15.05 434 222 0.22 / 781.84 2 2
2 12 1153.20 4 15.27 1993 122 0.34 / 781.96 2 2
3 7 1418.76 33 15.04 2265 1124 1.47 / 783.09 2 3
4 13 1299.52 21 15.00 2115 666 2.13 / 783.75 2 3
5 13 799.00 21 15.05 1443 456 2.59 / 784.21 2 5
6 13 133.68 21 15.16 504 160 2.75 / 784.37 2 3
7 13 35.32 21 15.17 358 114 2.86 / 784.49 2 3
8 8 0.00 175 15.13 298 789 3.65 / 785.27 2 7
Average= 4.11
(KJ/cycle)

Cycle 189 GMT 23/ 2/2024 8:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.28 34 15.03 429 219 0.22 / 777.73 2 2
2 12 1174.44 4 15.25 2012 123 0.34 / 777.86 2 2
3 7 2001.88 32 14.84 3024 1436 1.78 / 779.29 2 3
4 13 1523.24 21 14.84 2416 753 2.53 / 780.05 2 4
5 13 863.44 21 14.92 1535 481 3.01 / 780.53 2 4
6 13 194.08 21 15.08 586 186 3.20 / 780.71 2 3
7 13 51.60 21 15.11 382 121 3.32 / 780.83 2 3
8 8 0.00 175 15.08 298 786 4.11 / 781.62 2 5
Average= 4.11
(KJ/cycle)

Cycle 188 GMT 13/ 2/2024 9:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.52 34 15.04 427 218 0.22 / 773.43 2 2
2 12 1167.80 4 15.24 2026 124 0.34 / 773.55 2 2
3 7 2005.24 32 14.83 3011 1429 1.77 / 774.98 2 4
4 13 1510.04 21 14.84 2401 748 2.52 / 775.73 2 3
5 13 986.04 21 14.88 1715 536 3.05 / 776.27 2 4
6 13 271.00 21 15.05 697 220 3.28 / 776.49 2 3
7 13 66.84 21 15.09 403 128 3.40 / 776.61 2 3
8 13 16.44 21 15.10 336 107 3.51 / 776.72 2 3
9 8 0.04 175 15.06 302 796 4.31 / 777.52 2 5
Average= 4.11
(KJ/cycle)

Cycle 187 GMT 3/ 2/2024 11:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.92 34 15.05 438 224 0.22 / 769.27 2 2
2 12 1181.48 4 15.25 2037 124 0.35 / 769.40 2 2
3 7 2004.36 32 14.83 3010 1428 1.78 / 770.82 2 5
4 13 1510.76 21 14.84 2381 742 2.52 / 771.57 2 3
5 13 974.84 21 14.89 1684 527 3.05 / 772.09 2 4
6 13 255.64 21 15.05 671 212 3.26 / 772.31 2 3
7 13 67.64 21 15.09 400 127 3.38 / 772.43 2 3
8 8 0.08 175 15.07 295 778 4.16 / 773.21 2 5
Average= 4.11
(KJ/cycle)

Cycle 186 GMT 24/ 1/2024 13:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.76 34 15.05 434 222 0.22 / 765.03 2 2
2 12 1183.88 4 15.26 2019 123 0.35 / 765.15 2 2
3 7 2006.76 32 14.84 3007 1428 1.77 / 766.58 2 4
4 13 1672.84 21 14.82 2593 807 2.58 / 767.38 2 3
5 13 962.32 21 14.89 1670 522 3.10 / 767.91 2 4
6 13 257.04 21 15.06 685 217 3.32 / 768.12 2 3
7 13 75.48 21 15.10 418 133 3.45 / 768.26 2 3
8 8 0.16 175 15.08 300 792 4.24 / 769.05 2 6
Average= 4.11
(KJ/cycle)

Cycle 185 GMT 14/ 1/2024 15:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.44 34 15.06 431 221 0.22 / 760.78 2 2
2 12 1182.88 4 15.25 2009 123 0.34 / 760.90 2 2
3 7 2006.72 32 14.83 3013 1430 1.77 / 762.33 2 3
4 13 1674.60 21 14.81 2606 810 2.58 / 763.15 2 5
5 13 960.72 21 14.89 1671 523 3.11 / 763.67 2 4
6 13 273.08 21 15.05 702 222 3.33 / 763.89 2 3
7 13 80.32 21 15.10 414 131 3.46 / 764.02 2 3
8 8 0.12 175 15.08 297 784 4.24 / 764.80 2 6
Average= 4.11
(KJ/cycle)

Cycle 184 GMT 4/ 1/2024 16:56: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.44 34 15.05 431 221 0.22 / 756.57 2 2
2 12 1189.76 4 15.25 2059 126 0.35 / 756.69 2 2
3 7 2006.16 33 14.82 3013 1474 1.82 / 758.17 2 4
4 13 1508.16 21 14.84 2400 748 2.57 / 758.92 2 3
5 13 972.32 21 14.89 1690 528 3.10 / 759.44 2 4
6 13 263.24 21 15.06 687 217 3.31 / 759.66 2 3
7 13 77.64 21 15.10 409 130 3.44 / 759.79 2 3
8 8 0.04 175 15.08 292 771 4.21 / 760.56 2 6
Average= 4.11
(KJ/cycle)

Cycle 183 GMT 25/12/2023 18:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.64 34 15.05 430 220 0.22 / 752.39 2 2
2 12 1177.04 4 15.25 2034 124 0.34 / 752.51 2 2
3 7 2003.64 32 14.83 3012 1429 1.77 / 753.94 2 4
4 13 1518.28 21 14.84 2407 750 2.52 / 754.69 2 3
5 13 983.84 21 14.89 1699 531 3.05 / 755.23 2 4
6 13 281.56 21 15.05 709 224 3.28 / 755.45 2 3
7 13 74.96 21 15.10 411 130 3.41 / 755.58 2 3
8 8 -0.04 175 15.08 291 768 4.18 / 756.35 2 7
Average= 4.11
(KJ/cycle)

Cycle 182 GMT 15/12/2023 20:30: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.96 34 15.05 431 221 0.22 / 748.21 2 2
2 12 1179.56 4 15.26 2052 125 0.35 / 748.34 2 2
3 7 2004.20 32 14.83 3025 1436 1.78 / 749.77 2 5
4 13 1501.00 21 14.85 2392 746 2.53 / 750.52 2 4
5 13 985.04 21 14.89 1709 534 3.06 / 751.05 2 5
6 13 270.48 21 15.06 695 220 3.28 / 751.27 2 3
7 13 60.72 21 15.10 390 124 3.41 / 751.39 2 3
8 8 0.32 175 15.08 294 776 4.18 / 752.17 2 6
Average= 4.11
(KJ/cycle)

Cycle 181 GMT 5/12/2023 22:15:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.60 34 15.04 437 223 0.22 / 744.04 2 2
2 12 1182.56 4 15.25 2036 124 0.35 / 744.16 2 2
3 7 2004.72 32 14.84 3008 1428 1.78 / 745.59 2 4
4 13 1526.40 21 14.84 2414 752 2.53 / 746.34 2 4
5 13 1004.40 21 14.88 1722 538 3.07 / 746.88 2 4
6 13 183.12 21 15.08 579 183 3.25 / 747.07 2 3
7 13 57.48 21 15.11 399 127 3.38 / 747.19 2 3
8 8 0.04 175 15.09 302 798 4.17 / 747.99 2 7
Average= 4.11
(KJ/cycle)

Cycle 180 GMT 25/11/2023 23:46: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.28 34 15.07 431 221 0.22 / 739.88 2 2
2 12 1193.32 4 15.25 2053 125 0.35 / 740.00 2 2
3 7 2002.76 32 14.83 3008 1427 1.77 / 741.43 2 4
4 13 1508.08 21 14.85 2397 748 2.52 / 742.18 2 3
5 13 973.64 21 14.90 1680 526 3.05 / 742.70 2 3
6 13 255.60 21 15.06 672 213 3.26 / 742.92 2 3
7 13 60.84 21 15.10 387 123 3.38 / 743.04 2 3
8 8 0.00 175 15.08 294 776 4.16 / 743.82 2 7
Average= 4.11
(KJ/cycle)

Cycle 179 GMT 16/11/2023 1:35:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.44 34 15.04 442 226 0.23 / 735.77 2 2
2 12 1162.72 4 15.26 1995 122 0.35 / 735.89 2 2
3 7 2001.40 32 14.83 3020 1433 1.78 / 737.33 2 5
4 13 1510.92 21 14.85 2405 750 2.53 / 738.08 2 5
5 13 852.32 21 14.93 1522 477 3.01 / 738.55 2 4
6 13 214.08 21 15.08 622 197 3.21 / 738.75 2 3
7 13 63.68 21 15.11 398 126 3.33 / 738.88 2 3
8 8 -0.04 175 15.10 296 782 4.11 / 739.66 2 7
Average= 4.11
(KJ/cycle)

Cycle 178 GMT 6/11/2023 2:59: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.00 34 15.06 433 222 0.22 / 731.66 2 2
2 12 1173.00 4 15.26 2025 124 0.35 / 731.79 2 2
3 7 2004.20 32 14.84 3005 1427 1.77 / 733.21 2 3
4 13 1519.16 21 14.84 2411 751 2.52 / 733.97 2 4
5 13 863.36 21 14.92 1537 482 3.01 / 734.45 2 3
6 13 202.56 21 15.07 604 191 3.20 / 734.64 2 3
7 13 52.00 21 15.10 377 120 3.32 / 734.76 2 3
8 8 -0.04 175 15.08 298 786 4.10 / 735.54 2 6
Average= 4.11
(KJ/cycle)

Cycle 177 GMT 27/10/2023 4:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.00 34 15.04 435 222 0.22 / 727.56 2 2
2 12 1185.48 4 15.26 2028 124 0.35 / 727.69 2 2
3 7 2005.88 33 14.84 3013 1476 1.82 / 729.16 2 3
4 13 1489.96 21 14.85 2374 740 2.56 / 729.90 2 4
5 13 825.00 21 14.94 1479 464 3.03 / 730.37 2 4
6 13 193.00 21 15.09 573 182 3.21 / 730.55 2 3
7 13 51.40 21 15.12 375 119 3.33 / 730.67 2 3
8 8 0.08 175 15.09 293 774 4.10 / 731.44 2 5
Average= 4.11
(KJ/cycle)

Cycle 176 GMT 17/10/2023 6: 6: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.20 34 15.07 427 219 0.22 / 723.36 2 2
2 12 1177.76 4 15.26 2036 124 0.34 / 723.48 2 2
3 7 2008.24 32 14.84 3016 1432 1.78 / 724.91 2 3
4 13 1510.92 21 14.85 2396 747 2.52 / 725.66 2 4
5 13 1001.28 21 14.90 1725 540 3.06 / 726.20 2 3
6 13 283.04 21 15.05 733 232 3.29 / 726.43 2 3
7 13 71.08 21 15.10 407 129 3.42 / 726.56 2 3
8 8 -0.04 175 15.08 296 781 4.20 / 727.34 2 7
Average= 4.11
(KJ/cycle)

Cycle 175 GMT 7/10/2023 7:48:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.68 34 15.05 432 221 0.22 / 719.28 2 2
2 12 1175.00 4 15.26 2035 124 0.35 / 719.41 2 2
3 7 2003.52 32 14.84 3006 1427 1.77 / 720.83 2 3
4 13 1511.84 21 14.85 2394 747 2.52 / 721.58 2 4
5 13 859.04 21 14.93 1526 478 3.00 / 722.06 2 4
6 13 196.52 21 15.09 585 185 3.18 / 722.25 2 3
7 13 62.28 21 15.12 388 123 3.31 / 722.37 2 2
8 8 0.20 175 15.10 291 769 4.08 / 723.14 2 7
Average= 4.11
(KJ/cycle)

Cycle 174 GMT 27/ 9/2023 9:14: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.32 34 15.05 433 222 0.22 / 715.14 2 2
2 12 1163.28 4 15.27 1998 122 0.34 / 715.26 2 2
3 7 2009.48 32 14.84 3033 1440 1.78 / 716.70 2 3
4 13 1547.92 21 14.84 2458 766 2.55 / 717.46 2 5
5 13 874.00 21 14.92 1553 487 3.04 / 717.95 2 4
6 13 205.16 21 15.08 603 191 3.23 / 718.14 2 3
7 13 52.12 21 15.11 387 123 3.35 / 718.26 2 3
8 8 0.08 175 15.08 302 797 4.15 / 719.06 2 4
Average= 4.11
(KJ/cycle)

Cycle 173 GMT 17/ 9/2023 10:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.40 34 15.04 464 237 0.24 / 710.94 2 2
2 12 1178.88 4 15.27 2038 124 0.36 / 711.07 2 2
3 7 2003.80 32 14.84 3008 1428 1.79 / 712.50 2 4
4 13 1507.84 21 14.86 2398 748 2.54 / 713.24 2 4
5 13 989.00 21 14.90 1705 533 3.07 / 713.78 2 4
6 13 271.44 21 15.07 698 221 3.29 / 714.00 2 3
7 13 50.84 21 15.12 383 122 3.41 / 714.12 2 3
8 8 0.16 175 15.09 301 795 4.21 / 714.91 2 7
Average= 4.11
(KJ/cycle)

Cycle 172 GMT 7/ 9/2023 12:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.12 34 15.03 445 227 0.23 / 706.73 2 2
2 12 1163.92 4 15.26 2008 123 0.35 / 706.85 2 2
3 7 2002.96 32 14.83 3012 1429 1.78 / 708.28 2 3
4 13 1665.92 21 14.82 2597 808 2.59 / 709.09 2 4
5 13 927.84 21 14.91 1625 509 3.10 / 709.60 2 3
6 13 220.96 21 15.07 628 199 3.30 / 709.80 2 3
7 13 19.92 21 15.12 340 108 3.40 / 709.90 2 3
8 8 -0.16 175 15.08 304 802 4.21 / 710.71 2 5
Average= 4.11
(KJ/cycle)

Cycle 171 GMT 28/ 8/2023 14:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.08 34 15.05 439 225 0.22 / 702.45 2 2
2 3 1019.24 1 15.25 1799 27 0.25 / 702.48 2 4
3 12 1179.20 4 15.27 2040 125 0.38 / 702.60 2 2
4 7 2003.92 33 14.83 3035 1485 1.86 / 704.09 2 3
5 13 1508.80 21 14.85 2406 750 2.61 / 704.84 2 3
6 13 978.40 21 14.90 1707 534 3.15 / 705.37 2 4
7 13 262.60 21 15.06 695 220 3.37 / 705.59 2 3
8 13 59.84 21 15.10 390 124 3.49 / 705.71 2 3
9 8 -0.04 175 15.07 298 786 4.28 / 706.50 2 6
Average= 4.11
(KJ/cycle)

Cycle 170 GMT 18/ 8/2023 16: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.12 34 15.07 436 223 0.22 / 698.26 2 2
2 12 1186.76 4 15.27 2045 125 0.35 / 698.39 2 2
3 7 2000.84 32 14.85 3006 1428 1.78 / 699.82 2 3
4 13 1506.20 21 14.86 2387 745 2.52 / 700.56 2 3
5 13 984.68 21 14.90 1706 534 3.06 / 701.10 2 4
6 13 275.56 21 15.07 704 223 3.28 / 701.32 2 3
7 13 63.88 21 15.11 397 126 3.40 / 701.45 2 3
8 8 0.00 175 15.09 295 779 4.18 / 702.22 2 5
Average= 4.11
(KJ/cycle)

Cycle 169 GMT 8/ 8/2023 17:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.04 34 15.06 439 225 0.22 / 694.02 2 2
2 12 1179.24 4 15.27 2045 125 0.35 / 694.15 2 2
3 7 2001.52 32 14.85 3028 1439 1.79 / 695.58 2 3
4 13 1663.68 21 14.83 2606 812 2.60 / 696.40 2 5
5 13 957.68 21 14.91 1679 526 3.13 / 696.92 2 5
6 13 249.80 21 15.08 675 214 3.34 / 697.14 2 3
7 13 25.84 21 15.13 348 111 3.45 / 697.25 2 3
8 8 0.00 175 15.10 301 795 4.25 / 698.04 2 5
Average= 4.11
(KJ/cycle)

Cycle 168 GMT 29/ 7/2023 19:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.40 34 15.05 438 224 0.22 / 689.99 2 2
2 12 1175.40 4 15.27 2049 125 0.35 / 690.12 2 2
3 7 2003.12 33 14.84 3015 1477 1.83 / 691.59 2 4
4 13 1495.88 21 14.85 2389 745 2.57 / 692.34 2 5
5 13 830.28 21 14.93 1514 475 3.05 / 692.81 2 5
6 13 157.44 21 15.10 544 173 3.22 / 692.98 2 3
7 8 0.12 175 15.10 307 811 4.03 / 693.80 2 9
Average= 4.11
(KJ/cycle)

Cycle 167 GMT 19/ 7/2023 20:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.80 34 15.04 472 241 0.24 / 685.84 2 2
2 12 1180.52 4 15.27 2046 125 0.37 / 685.96 2 2
3 7 2007.20 32 14.84 3028 1438 1.80 / 687.40 2 3
4 13 1516.68 21 14.85 2409 751 2.56 / 688.15 2 4
5 13 992.08 21 14.90 1712 536 3.09 / 688.69 2 5
6 13 149.92 21 15.10 530 168 3.26 / 688.85 2 3
7 13 15.36 21 15.13 333 106 3.37 / 688.96 2 3
8 8 0.12 175 15.09 305 805 4.17 / 689.77 2 7
Average= 4.11
(KJ/cycle)

Cycle 166 GMT 9/ 7/2023 22:39: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.36 34 15.04 456 233 0.23 / 681.69 2 2
2 12 1184.04 4 15.27 2041 125 0.36 / 681.82 2 2
3 7 2004.96 32 14.84 3026 1437 1.79 / 683.26 2 2
4 13 1516.76 21 14.85 2420 755 2.55 / 684.01 2 3
5 13 876.28 21 14.92 1566 491 3.04 / 684.50 2 4
6 13 191.16 21 15.09 589 187 3.23 / 684.69 2 3
7 13 21.00 21 15.12 341 108 3.34 / 684.80 2 3
8 8 -0.08 175 15.09 303 800 4.14 / 685.60 2 6
Average= 4.11
(KJ/cycle)

Cycle 165 GMT 30/ 6/2023 0: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.76 34 15.05 468 239 0.24 / 677.71 2 2
2 12 1176.48 4 15.28 2030 124 0.36 / 677.83 2 2
3 7 2004.00 32 14.84 3015 1432 1.80 / 679.26 2 3
4 13 1506.52 21 14.85 2399 748 2.54 / 680.01 2 4
5 13 848.40 21 14.94 1512 474 3.02 / 680.49 2 5
6 13 172.56 21 15.09 560 177 3.20 / 680.66 2 3
7 8 0.00 175 15.09 302 798 3.99 / 681.46 2 9
Average= 4.11
(KJ/cycle)

Cycle 164 GMT 20/ 6/2023 1:39: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.28 34 15.04 441 226 0.23 / 673.63 2 2
2 12 1194.84 4 15.27 2047 125 0.35 / 673.75 2 2
3 7 2001.52 32 14.86 2993 1423 1.77 / 675.18 2 3
4 13 1500.04 21 14.87 2374 741 2.52 / 675.92 2 3
5 13 843.84 21 14.96 1497 470 2.99 / 676.39 2 4
6 13 179.60 21 15.10 564 179 3.16 / 676.57 2 3
7 13 19.28 21 15.13 336 107 3.27 / 676.68 2 3
8 8 0.08 175 15.09 300 792 4.06 / 677.47 2 8
Average= 4.11
(KJ/cycle)

Cycle 163 GMT 10/ 6/2023 3:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.64 34 15.05 452 231 0.23 / 669.43 2 2
2 12 1181.08 4 15.28 2030 124 0.36 / 669.55 2 2
3 7 2005.64 32 14.86 3018 1435 1.79 / 670.99 2 3
4 13 1505.00 21 14.87 2391 747 2.54 / 671.73 2 4
5 13 985.24 21 14.91 1699 532 3.07 / 672.27 2 5
6 13 264.64 21 15.08 684 217 3.29 / 672.48 2 3
7 13 46.08 21 15.12 377 120 3.41 / 672.60 2 3
8 8 0.00 175 15.09 304 803 4.21 / 673.40 2 7
Average= 4.11
(KJ/cycle)

Cycle 162 GMT 31/ 5/2023 5:35:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.64 34 15.06 448 229 0.23 / 665.22 2 2
2 12 1187.48 4 15.27 2050 125 0.35 / 665.34 2 2
3 7 2001.68 32 14.85 3019 1435 1.79 / 666.78 2 3
4 13 1663.76 21 14.83 2588 806 2.60 / 667.58 2 5
5 13 956.20 21 14.92 1665 522 3.12 / 668.11 2 4
6 13 149.20 21 15.11 532 169 3.29 / 668.27 2 3
7 13 16.64 21 15.13 343 109 3.39 / 668.38 2 3
8 8 0.08 175 15.09 308 813 4.21 / 669.20 2 6
Average= 4.11
(KJ/cycle)

Cycle 161 GMT 21/ 5/2023 7:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.16 34 15.06 454 232 0.23 / 661.14 2 2
2 12 1160.44 4 15.28 2008 123 0.36 / 661.27 2 2
3 7 2002.40 32 14.85 3009 1430 1.79 / 662.70 2 3
4 13 1490.52 21 14.86 2381 743 2.53 / 663.44 2 4
5 13 963.84 21 14.92 1680 526 3.05 / 663.97 2 3
6 13 230.60 21 15.08 649 206 3.26 / 664.17 2 3
7 8 0.12 175 15.10 309 817 4.08 / 664.99 2 8
Average= 4.10
(KJ/cycle)

Cycle 160 GMT 11/ 5/2023 9:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.76 34 15.03 429 219 0.22 / 657.13 2 2
2 12 1172.92 4 15.28 2019 123 0.34 / 657.26 2 2
3 7 2003.48 32 14.85 3004 1428 1.77 / 658.68 2 3
4 13 1495.56 21 14.86 2382 743 2.51 / 659.43 2 3
5 13 967.00 21 14.91 1678 525 3.04 / 659.95 2 4
6 13 133.12 21 15.10 503 160 3.20 / 660.11 2 3
7 8 0.08 175 15.10 303 801 4.00 / 660.91 2 8
Average= 4.11
(KJ/cycle)

Cycle 159 GMT 1/ 5/2023 11: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.88 34 15.03 436 223 0.22 / 652.90 2 2
2 12 1185.68 4 15.28 2029 124 0.35 / 653.02 2 2
3 7 2005.96 32 14.85 3021 1436 1.78 / 654.46 2 3
4 13 1523.56 21 14.86 2419 755 2.54 / 655.21 2 4
5 13 1018.16 21 14.90 1747 547 3.08 / 655.76 2 4
6 13 294.92 21 15.06 729 231 3.31 / 655.99 2 3
7 13 51.36 21 15.10 388 123 3.44 / 656.11 2 3
8 8 0.00 175 15.07 303 799 4.24 / 656.91 2 7
Average= 4.11
(KJ/cycle)

Cycle 158 GMT 21/ 4/2023 12:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.28 34 15.04 450 230 0.23 / 648.77 2 2
2 12 1168.64 4 15.30 2014 123 0.35 / 648.89 2 2
3 7 2003.04 32 14.86 2985 1419 1.77 / 650.31 2 3
4 13 1492.96 21 14.87 2370 740 2.51 / 651.05 2 3
5 13 839.76 21 14.95 1495 469 2.98 / 651.52 2 4
6 13 303.84 21 15.06 744 235 3.22 / 651.76 2 3
7 13 26.56 21 15.11 350 111 3.33 / 651.87 2 3
8 8 -0.04 175 15.08 306 808 4.14 / 652.68 2 6
Average= 4.10
(KJ/cycle)

Cycle 157 GMT 11/ 4/2023 14:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.68 34 15.05 451 231 0.23 / 644.56 2 2
2 12 1190.84 4 15.29 2037 125 0.36 / 644.68 2 2
3 7 2002.08 32 14.87 3006 1430 1.79 / 646.11 2 3
4 13 1521.28 21 14.86 2414 753 2.54 / 646.86 2 3
5 13 1001.32 21 14.91 1726 540 3.08 / 647.40 2 4
6 13 268.48 21 15.07 694 220 3.30 / 647.62 2 3
7 13 30.76 21 15.12 357 113 3.41 / 647.74 2 3
8 8 -0.04 175 15.08 304 802 4.21 / 648.54 2 7
Average= 4.10
(KJ/cycle)

Cycle 156 GMT 1/ 4/2023 16:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.88 34 15.05 453 232 0.23 / 640.40 2 2
2 12 1178.44 4 15.29 2033 124 0.36 / 640.52 2 2
3 7 2002.80 32 14.87 3002 1428 1.78 / 641.95 2 3
4 13 1504.52 21 14.87 2389 746 2.53 / 642.70 2 3
5 13 987.16 21 14.92 1701 533 3.06 / 643.23 2 4
6 13 155.44 21 15.11 545 173 3.24 / 643.40 2 3
7 13 38.32 21 15.12 368 117 3.35 / 643.52 2 3
8 8 0.00 175 15.09 305 805 4.16 / 644.33 2 8
Average= 4.10
(KJ/cycle)

Cycle 155 GMT 22/ 3/2023 18:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.00 34 15.05 439 225 0.22 / 636.22 2 2
2 12 1196.68 4 15.28 2045 125 0.35 / 636.34 2 2
3 7 2003.08 32 14.87 2997 1426 1.78 / 637.77 2 4
4 13 1490.00 21 14.87 2367 739 2.51 / 638.51 2 3
5 13 974.36 21 14.92 1684 528 3.04 / 639.04 2 4
6 13 244.96 21 15.08 666 211 3.25 / 639.25 2 3
7 13 25.80 21 15.13 353 112 3.37 / 639.36 2 3
8 8 0.04 175 15.09 306 808 4.17 / 640.17 2 6
Average= 4.10
(KJ/cycle)

Cycle 154 GMT 12/ 3/2023 20:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.76 34 15.06 448 229 0.23 / 632.04 2 2
2 12 1151.36 4 15.29 1984 121 0.35 / 632.16 2 2
3 7 2002.16 32 14.87 3005 1430 1.78 / 633.59 2 2
4 13 1510.52 21 14.87 2394 748 2.53 / 634.34 2 3
5 13 961.52 21 14.93 1669 523 3.05 / 634.86 2 4
6 13 260.68 21 15.08 686 217 3.27 / 635.08 2 3
7 13 43.96 21 15.12 376 119 3.39 / 635.20 2 3
8 8 0.04 175 15.09 302 798 4.19 / 635.99 2 6
Average= 4.10
(KJ/cycle)

Cycle 153 GMT 2/ 3/2023 22:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.56 34 15.06 432 221 0.22 / 627.86 2 2
2 12 1170.40 4 15.30 2019 124 0.34 / 627.99 2 2
3 7 2004.40 32 14.86 3012 1432 1.78 / 629.42 2 3
4 13 1513.40 21 14.87 2405 751 2.53 / 630.17 2 4
5 13 986.44 21 14.92 1702 533 3.06 / 630.70 2 3
6 13 150.00 21 15.11 533 169 3.23 / 630.87 2 3
7 13 29.12 21 15.13 367 117 3.35 / 630.99 2 3
8 8 0.08 175 15.09 310 819 4.17 / 631.81 2 7
Average= 4.10
(KJ/cycle)

Cycle 152 GMT 21/ 2/2023 0:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.68 34 15.05 429 220 0.22 / 623.66 2 2
2 12 1213.88 4 15.28 2067 126 0.35 / 623.79 2 2
3 7 2001.76 32 14.86 2997 1425 1.77 / 625.21 2 3
4 13 1648.12 21 14.86 2567 801 2.57 / 626.02 2 4
5 13 933.00 21 14.95 1628 511 3.08 / 626.53 2 4
6 13 210.44 21 15.10 617 196 3.28 / 626.72 2 3
7 13 34.76 21 15.14 366 116 3.40 / 626.84 2 3
8 8 0.00 175 15.10 304 803 4.20 / 627.64 2 8
Average= 4.10
(KJ/cycle)

Cycle 151 GMT 11/ 2/2023 2:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.84 34 15.05 440 225 0.23 / 619.48 2 2
2 12 1165.88 4 15.30 2011 123 0.35 / 619.60 2 2
3 7 2006.32 33 14.86 3008 1475 1.82 / 621.08 2 3
4 13 1495.76 21 14.87 2383 744 2.57 / 621.82 2 3
5 13 1008.80 21 14.91 1737 544 3.11 / 622.36 2 4
6 13 149.12 21 15.11 525 167 3.28 / 622.53 2 3
7 13 31.56 21 15.13 361 115 3.39 / 622.64 2 3
8 8 -0.04 175 15.10 302 798 4.19 / 623.44 2 9
Average= 4.10
(KJ/cycle)

Cycle 150 GMT 1/ 2/2023 4:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.52 34 15.05 448 229 0.23 / 615.26 2 2
2 12 1188.84 4 15.29 2044 125 0.35 / 615.38 2 2
3 7 2001.52 32 14.87 3001 1428 1.78 / 616.81 2 4
4 13 1514.04 21 14.87 2400 749 2.53 / 617.56 2 5
5 13 990.24 21 14.92 1712 536 3.07 / 618.09 2 4
6 13 266.60 21 15.08 697 221 3.29 / 618.32 2 3
7 13 48.84 21 15.12 389 124 3.41 / 618.44 2 3
8 8 0.12 175 15.09 308 813 4.23 / 619.25 2 10
Average= 4.10
(KJ/cycle)

Cycle 149 GMT 22/ 1/2023 5:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.48 34 15.05 458 234 0.23 / 611.09 2 2
2 12 1184.28 4 15.29 2039 125 0.36 / 611.22 2 2
3 7 2014.80 32 14.86 3027 1439 1.80 / 612.66 2 3
4 13 1517.16 21 14.87 2415 754 2.55 / 613.41 2 3
5 13 992.20 21 14.92 1715 537 3.09 / 613.95 2 4
6 13 141.60 21 15.11 514 163 3.25 / 614.11 2 3
7 13 31.16 21 15.12 359 114 3.37 / 614.23 2 3
8 8 -0.04 175 15.09 303 800 4.17 / 615.03 2 8
Average= 4.10
(KJ/cycle)

Cycle 148 GMT 12/ 1/2023 7:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.36 34 15.06 436 223 0.22 / 606.96 2 2
2 12 1195.28 4 15.28 2053 125 0.35 / 607.08 2 2
3 7 2003.08 32 14.87 3008 1431 1.78 / 608.51 2 3
4 13 1529.52 21 14.87 2439 762 2.54 / 609.27 2 3
5 13 862.12 21 14.95 1543 484 3.03 / 609.76 2 4
6 13 173.24 21 15.11 564 179 3.21 / 609.94 2 3
7 13 37.88 21 15.13 368 117 3.32 / 610.05 2 3
8 8 0.04 175 15.09 305 805 4.13 / 610.86 2 8
Average= 4.10
(KJ/cycle)

Cycle 147 GMT 2/ 1/2023 8:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.28 34 15.06 449 230 0.23 / 602.79 2 2
2 12 1176.84 4 15.29 2053 126 0.36 / 602.91 2 2
3 7 2002.40 32 14.85 3007 1429 1.78 / 604.34 2 5
4 13 1505.80 21 14.87 2403 750 2.53 / 605.09 2 4
5 13 991.64 21 14.92 1722 540 3.07 / 605.63 2 5
6 13 152.08 21 15.11 535 170 3.24 / 605.80 2 3
7 13 33.56 21 15.14 363 115 3.36 / 605.92 2 3
8 8 0.04 175 15.10 308 814 4.17 / 606.73 2 5
Average= 4.10
(KJ/cycle)

Cycle 146 GMT 23/12/2022 9:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.64 34 15.07 460 236 0.24 / 598.73 2 2
2 12 1176.88 4 15.29 2024 124 0.36 / 598.85 2 2
3 7 1863.08 32 14.90 2847 1357 1.72 / 600.21 2 4
4 13 1401.60 21 14.92 2263 709 2.43 / 600.92 2 3
5 13 923.04 21 14.96 1625 511 2.94 / 601.43 2 4
6 13 201.96 21 15.11 605 192 3.13 / 601.62 2 3
7 13 34.36 21 15.14 366 116 3.24 / 601.74 2 3
8 8 -0.12 175 15.10 311 822 4.07 / 602.56 2 7
Average= 4.10
(KJ/cycle)

Cycle 145 GMT 13/12/2022 9:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.20 34 15.08 455 233 0.23 / 594.51 2 2
2 12 1164.20 4 15.30 2007 123 0.36 / 594.64 2 2
3 7 2002.56 32 14.87 3010 1432 1.79 / 596.07 2 5
4 13 1496.20 21 14.88 2387 746 2.53 / 596.81 2 5
5 13 980.12 21 14.93 1709 536 3.07 / 597.35 2 4
6 13 263.96 21 15.09 692 219 3.29 / 597.57 2 3
7 13 27.36 21 15.15 356 113 3.40 / 597.68 2 3
8 8 0.20 175 15.11 306 809 4.21 / 598.49 2 7
Average= 4.10
(KJ/cycle)

Cycle 144 GMT 3/12/2022 11: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.00 34 15.07 460 236 0.24 / 590.44 2 2
2 12 1183.72 4 15.28 2035 124 0.36 / 590.57 2 2
3 7 2006.88 32 14.87 3023 1438 1.80 / 592.01 2 4
4 13 1495.88 21 14.88 2398 749 2.55 / 592.76 2 3
5 13 970.48 21 14.94 1688 530 3.08 / 593.29 2 5
6 13 134.84 21 15.13 513 163 3.24 / 593.45 2 3
7 8 0.04 175 15.12 314 831 4.07 / 594.28 2 10
Average= 4.10
(KJ/cycle)

Cycle 143 GMT 23/11/2022 12:55: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.64 34 15.07 458 235 0.23 / 586.36 2 2
2 12 1189.04 4 15.28 2048 125 0.36 / 586.49 2 2
3 7 2005.04 32 14.87 3028 1441 1.80 / 587.93 2 4
4 13 1503.28 21 14.88 2399 750 2.55 / 588.68 2 3
5 13 1005.32 21 14.93 1738 545 3.10 / 589.22 2 4
6 13 148.64 21 15.12 530 168 3.26 / 589.39 2 3
7 8 -0.04 175 15.12 309 818 4.08 / 590.21 2 10
Average= 4.10
(KJ/cycle)

Cycle 142 GMT 13/11/2022 14:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.04 34 15.05 456 233 0.23 / 582.15 2 2
2 12 1179.12 4 15.29 2045 125 0.36 / 582.28 2 2
3 7 2003.28 32 14.86 3019 1436 1.79 / 583.72 2 3
4 13 1497.40 21 14.88 2385 745 2.54 / 584.46 2 3
5 13 976.52 21 14.93 1696 532 3.07 / 584.99 2 5
6 13 248.88 21 15.10 671 213 3.28 / 585.20 2 3
7 13 21.72 21 15.15 349 111 3.39 / 585.32 2 3
8 8 0.00 175 15.11 307 812 4.21 / 586.13 2 8
Average= 4.10
(KJ/cycle)

Cycle 141 GMT 3/11/2022 16:35:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.00 34 15.05 472 242 0.24 / 577.92 2 2
2 12 1173.84 4 15.28 2027 124 0.37 / 578.04 2 2
3 7 2003.88 32 14.87 3019 1437 1.80 / 579.48 2 3
4 13 1486.56 21 14.88 2375 742 2.54 / 580.22 2 5
5 13 980.88 21 14.93 1716 538 3.08 / 580.76 2 5
6 13 249.36 21 15.09 680 215 3.30 / 580.97 2 3
7 13 19.84 21 15.14 352 112 3.41 / 581.09 2 3
8 8 0.04 175 15.10 316 835 4.24 / 581.92 2 7
Average= 4.10
(KJ/cycle)

Cycle 140 GMT 24/10/2022 18: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.12 34 15.08 450 231 0.23 / 573.66 2 2
2 12 1180.28 4 15.31 2022 124 0.35 / 573.79 2 2
3 7 2004.28 33 14.86 3011 1477 1.83 / 575.26 2 3
4 13 1519.24 21 14.88 2410 753 2.58 / 576.02 2 4
5 13 982.24 21 14.93 1695 531 3.12 / 576.55 2 4
6 13 231.52 21 15.10 645 205 3.32 / 576.75 2 3
7 13 40.44 21 15.13 375 119 3.44 / 576.87 2 3
8 8 -0.12 175 15.10 305 806 4.25 / 577.68 2 6
Average= 4.10
(KJ/cycle)

Cycle 139 GMT 14/10/2022 20: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.76 34 15.09 459 235 0.24 / 569.54 2 2
2 12 1177.96 4 15.31 2029 124 0.36 / 569.66 2 2
3 7 2002.48 32 14.87 3008 1431 1.79 / 571.09 2 5
4 13 1504.52 21 14.89 2388 747 2.54 / 571.84 2 3
5 13 967.96 21 14.94 1686 529 3.07 / 572.37 2 4
6 13 146.76 21 15.13 519 165 3.23 / 572.53 2 3
7 13 16.84 21 15.15 333 106 3.34 / 572.64 2 3
8 8 -0.04 175 15.12 299 791 4.13 / 573.43 2 5
Average= 4.10
(KJ/cycle)

Cycle 138 GMT 4/10/2022 21:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.68 34 15.09 462 237 0.24 / 565.48 2 2
2 12 1168.08 4 15.30 2015 123 0.36 / 565.60 2 2
3 7 2003.52 32 14.88 2999 1428 1.79 / 567.03 2 4
4 13 1519.16 21 14.88 2401 750 2.54 / 567.78 2 3
5 13 988.36 21 14.94 1716 538 3.08 / 568.32 2 5
6 13 144.60 21 15.13 528 168 3.24 / 568.49 2 3
7 8 -0.12 175 15.13 308 816 4.06 / 569.30 2 7
Average= 4.10
(KJ/cycle)

Cycle 137 GMT 24/ 9/2022 23: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.60 34 15.09 452 232 0.23 / 561.41 2 2
2 12 1177.64 4 15.31 2046 125 0.36 / 561.53 2 2
3 7 2001.96 32 14.88 3012 1434 1.79 / 562.97 2 3
4 13 1499.16 21 14.89 2394 749 2.54 / 563.71 2 4
5 13 990.48 21 14.94 1714 538 3.08 / 564.25 2 5
6 13 152.28 21 15.13 550 175 3.25 / 564.43 2 3
7 8 0.00 175 15.13 308 816 4.07 / 565.24 2 8
Average= 4.10
(KJ/cycle)

Cycle 136 GMT 15/ 9/2022 0:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.76 34 15.08 471 241 0.24 / 557.18 2 2
2 12 1180.12 4 15.29 2035 124 0.37 / 557.30 2 2
3 7 2002.84 32 14.88 3028 1442 1.81 / 558.74 2 4
4 13 1523.48 21 14.88 2418 756 2.56 / 559.50 2 4
5 13 999.32 21 14.93 1725 541 3.10 / 560.04 2 4
6 13 267.88 21 15.10 701 222 3.33 / 560.26 2 3
7 13 23.92 21 15.16 351 112 3.44 / 560.37 2 3
8 8 0.12 175 15.12 303 802 4.24 / 561.17 2 9
Average= 4.10
(KJ/cycle)

Cycle 135 GMT 5/ 9/2022 2:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.32 33 15.11 455 227 0.23 / 552.92 2 2
2 12 1193.00 4 15.29 2057 126 0.35 / 553.05 2 2
3 7 2001.24 32 14.88 3015 1436 1.79 / 554.48 2 3
4 13 1515.88 21 14.89 2420 757 2.55 / 555.24 2 4
5 13 986.76 21 14.94 1708 536 3.08 / 555.78 2 3
6 13 254.28 21 15.11 692 220 3.30 / 556.00 2 3
7 13 22.56 21 15.16 355 113 3.41 / 556.11 2 3
8 8 0.04 175 15.12 312 826 4.24 / 556.93 2 5
Average= 4.10
(KJ/cycle)

Cycle 134 GMT 26/ 8/2022 3:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.16 33 15.10 459 229 0.23 / 548.92 2 2
2 12 1185.76 4 15.30 2042 125 0.35 / 549.05 2 2
3 7 2002.60 32 14.88 3011 1434 1.79 / 550.48 2 5
4 13 1495.24 21 14.89 2391 748 2.54 / 551.23 2 4
5 13 834.24 21 14.98 1508 474 3.01 / 551.70 2 3
6 13 162.16 21 15.14 561 178 3.19 / 551.88 2 3
7 8 0.16 175 15.14 307 813 4.00 / 552.70 2 9
Average= 4.09
(KJ/cycle)

Cycle 133 GMT 16/ 8/2022 5:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.44 34 15.10 466 239 0.24 / 544.97 2 2
2 12 1289.48 4 15.26 2200 134 0.37 / 545.10 2 2
3 7 1872.92 32 14.91 2860 1365 1.74 / 546.47 2 3
4 13 1412.16 21 14.93 2278 714 2.45 / 547.18 2 4
5 13 909.40 21 14.98 1606 505 2.96 / 547.69 2 5
6 13 189.32 21 15.14 589 187 3.14 / 547.88 2 3
7 8 0.00 175 15.14 309 819 3.96 / 548.69 2 8
Average= 4.09
(KJ/cycle)

Cycle 132 GMT 6/ 8/2022 5: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.44 33 15.09 459 229 0.23 / 540.87 2 2
2 12 1189.28 4 15.30 2066 126 0.36 / 541.00 2 2
3 7 2005.28 32 14.88 3014 1435 1.79 / 542.43 2 4
4 13 1510.00 21 14.89 2398 750 2.54 / 543.18 2 4
5 13 966.80 21 14.95 1684 529 3.07 / 543.71 2 4
6 13 219.08 21 15.12 639 203 3.27 / 543.91 2 3
7 8 0.04 175 15.14 309 819 4.09 / 544.73 2 7
Average= 4.10
(KJ/cycle)

Cycle 131 GMT 27/ 7/2022 7: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.80 33 15.11 458 228 0.23 / 536.80 2 2
2 12 1170.08 4 15.30 2026 124 0.35 / 536.92 2 2
3 7 2006.40 32 14.88 3010 1433 1.79 / 538.35 2 3
4 13 1515.40 21 14.89 2418 756 2.54 / 539.11 2 4
5 13 991.76 21 14.94 1726 542 3.08 / 539.65 2 5
6 13 155.28 21 15.14 549 175 3.26 / 539.82 2 3
7 8 -0.20 175 15.14 308 816 4.07 / 540.64 2 7
Average= 4.10
(KJ/cycle)

Cycle 130 GMT 17/ 7/2022 8:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.00 33 15.11 459 229 0.23 / 532.72 2 2
2 12 1186.44 4 15.30 2050 125 0.35 / 532.85 2 2
3 7 2003.00 32 14.88 3022 1439 1.79 / 534.29 2 3
4 13 1515.52 21 14.89 2417 756 2.55 / 535.04 2 4
5 13 990.08 21 14.95 1713 538 3.09 / 535.58 2 5
6 13 153.20 21 15.15 539 171 3.26 / 535.75 2 3
7 8 0.16 175 15.15 308 817 4.07 / 536.57 2 8
Average= 4.10
(KJ/cycle)

Cycle 129 GMT 7/ 7/2022 10: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.28 33 15.11 442 220 0.22 / 528.60 2 2
2 12 1164.64 4 15.30 2013 123 0.34 / 528.72 2 2
3 7 2001.40 32 14.88 3012 1434 1.78 / 530.15 2 3
4 13 1513.32 21 14.89 2416 755 2.53 / 530.91 2 4
5 13 992.00 21 14.94 1722 540 3.07 / 531.45 2 5
6 13 280.48 21 15.12 714 227 3.30 / 531.68 2 3
7 8 0.00 175 15.15 308 817 4.12 / 532.49 2 6
Average= 4.10
(KJ/cycle)

Cycle 128 GMT 27/ 6/2022 11:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.60 34 15.10 440 226 0.23 / 524.49 2 2
2 12 1183.68 4 15.30 2046 125 0.35 / 524.62 2 2
3 7 2001.00 32 14.89 3012 1435 1.79 / 526.05 2 3
4 13 1504.48 21 14.89 2392 748 2.53 / 526.80 2 4
5 13 977.68 21 14.95 1700 534 3.07 / 527.33 2 4
6 13 260.96 21 15.12 698 222 3.29 / 527.56 2 3
7 8 0.28 175 15.15 309 819 4.11 / 528.37 2 6
Average= 4.10
(KJ/cycle)

Cycle 127 GMT 17/ 6/2022 13: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.60 34 15.11 443 228 0.23 / 520.24 2 2
2 12 1170.80 4 15.30 2039 125 0.35 / 520.36 2 2
3 7 2002.04 32 14.88 3019 1438 1.79 / 521.80 2 6
4 13 1512.40 21 14.89 2411 754 2.54 / 522.56 2 4
5 13 986.16 21 14.95 1712 537 3.08 / 523.09 2 4
6 13 263.72 21 15.12 698 222 3.30 / 523.31 2 3
7 13 41.28 21 15.17 384 122 3.43 / 523.44 2 3
8 8 0.04 175 15.14 313 829 4.25 / 524.27 2 12
Average= 4.10
(KJ/cycle)

Cycle 126 GMT 7/ 6/2022 14:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.12 34 15.10 458 235 0.24 / 516.04 2 2
2 12 1178.96 4 15.30 2044 125 0.36 / 516.17 2 2
3 7 2004.72 32 14.88 3022 1439 1.80 / 517.61 2 5
4 13 1525.84 21 14.89 2427 759 2.56 / 518.37 2 4
5 13 987.76 21 14.95 1719 540 3.10 / 518.91 2 4
6 13 155.96 21 15.16 542 173 3.27 / 519.08 2 3
7 13 35.16 21 15.18 372 119 3.39 / 519.20 2 3
8 8 0.04 175 15.15 307 814 4.20 / 520.01 2 7
Average= 4.09
(KJ/cycle)

Cycle 125 GMT 28/ 5/2022 15:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.36 34 15.11 440 226 0.23 / 511.89 2 2
2 12 1170.08 4 15.30 2021 124 0.35 / 512.01 2 2
3 7 2002.44 32 14.88 3021 1438 1.79 / 513.45 2 4
4 13 1510.80 21 14.89 2417 756 2.54 / 514.20 2 5
5 13 855.20 21 14.98 1539 484 3.03 / 514.69 2 5
6 13 174.04 21 15.14 583 185 3.21 / 514.87 2 3
7 13 36.12 21 15.17 372 119 3.33 / 514.99 2 3
8 8 0.08 175 15.14 308 816 4.15 / 515.81 2 8
Average= 4.09
(KJ/cycle)

Cycle 124 GMT 18/ 5/2022 17: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.72 34 15.09 462 237 0.24 / 507.84 2 2
2 12 1188.48 4 15.29 2057 126 0.36 / 507.97 2 2
3 7 2005.28 32 14.89 3014 1436 1.80 / 509.40 2 4
4 13 1492.92 21 14.90 2376 743 2.54 / 510.15 2 4
5 13 975.52 21 14.96 1701 534 3.08 / 510.68 2 5
6 13 138.28 21 15.16 519 165 3.24 / 510.85 2 3
7 8 0.12 175 15.16 307 814 4.06 / 511.66 2 9
Average= 4.09
(KJ/cycle)

Cycle 123 GMT 8/ 5/2022 18:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.84 34 15.08 469 240 0.24 / 503.56 2 2
2 12 1176.68 4 15.31 2042 125 0.37 / 503.68 2 2
3 7 2001.16 32 14.89 3010 1434 1.80 / 505.12 2 4
4 13 1666.80 21 14.87 2603 813 2.61 / 505.93 2 3
5 13 951.56 21 14.96 1655 520 3.13 / 506.45 2 5
6 13 251.88 21 15.12 678 215 3.35 / 506.66 2 3
7 13 23.36 21 15.17 363 116 3.46 / 506.78 2 3
8 8 -0.08 175 15.14 311 824 4.29 / 507.60 2 8
Average= 4.09
(KJ/cycle)

Cycle 122 GMT 28/ 4/2022 20:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 121.20 34 15.10 455 234 0.23 / 499.21 2 2
2 12 1186.80 4 15.31 2041 125 0.36 / 499.33 2 2
3 7 2004.88 32 14.89 3020 1439 1.80 / 500.77 2 3
4 13 1508.12 21 14.89 2404 752 2.55 / 501.52 2 4
5 13 1005.92 21 14.94 1739 546 3.09 / 502.07 2 4
6 13 257.20 21 15.12 681 216 3.31 / 502.29 2 3
7 13 48.96 21 15.16 386 123 3.43 / 502.41 2 3
8 8 -0.08 175 15.12 308 815 4.25 / 503.22 2 9
9 14 -0.08 20 15.10 308 93 4.34 / 503.32 2 7
Average= 4.09
(KJ/cycle)

Cycle 121 GMT 18/ 4/2022 22: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.04 34 15.09 434 223 0.22 / 495.02 2 2
2 12 1184.56 4 15.32 2038 125 0.35 / 495.15 2 2
3 7 2002.24 32 14.89 3010 1434 1.78 / 496.58 2 3
4 13 1513.00 21 14.90 2410 754 2.54 / 497.33 2 4
5 13 985.44 21 14.96 1717 539 3.08 / 497.87 2 5
6 13 153.64 21 15.15 537 171 3.25 / 498.04 2 3
7 13 39.72 21 15.17 377 120 3.37 / 498.16 2 3
8 8 0.04 175 15.14 306 811 4.18 / 498.97 2 7
Average= 4.09
(KJ/cycle)

Cycle 120 GMT 8/ 4/2022 23:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.76 34 15.11 451 232 0.23 / 490.82 2 2
2 12 1184.72 4 15.31 2048 125 0.36 / 490.95 2 2
3 7 2003.08 32 14.89 3014 1436 1.79 / 492.38 2 4
4 13 1488.56 21 14.91 2374 743 2.54 / 493.12 2 3
5 13 975.44 21 14.96 1691 531 3.07 / 493.66 2 4
6 13 237.56 21 15.13 664 211 3.28 / 493.87 2 3
7 13 42.00 21 15.17 378 120 3.40 / 493.99 2 3
8 8 -0.08 175 15.14 306 811 4.21 / 494.80 2 7
Average= 4.09
(KJ/cycle)

Cycle 119 GMT 30/ 3/2022 1:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.12 34 15.11 431 221 0.22 / 486.63 2 2
2 12 1175.32 4 15.31 2030 124 0.35 / 486.75 2 2
3 7 2002.88 33 14.88 3015 1480 1.83 / 488.23 2 3
4 13 1495.88 21 14.90 2382 745 2.57 / 488.98 2 3
5 13 977.20 21 14.95 1690 531 3.10 / 489.51 2 4
6 13 130.88 21 15.16 508 162 3.26 / 489.67 2 3
7 13 30.28 21 15.17 361 115 3.38 / 489.78 2 3
8 8 0.08 175 15.14 304 805 4.18 / 490.59 2 9
Average= 4.09
(KJ/cycle)

Cycle 118 GMT 20/ 3/2022 2:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.32 34 15.11 434 223 0.22 / 482.46 2 2
2 12 1183.64 4 15.31 2026 124 0.35 / 482.58 2 2
3 7 2004.52 32 14.89 3023 1440 1.79 / 484.02 2 4
4 13 1509.68 21 14.90 2402 752 2.54 / 484.77 2 4
5 13 998.08 21 14.95 1735 545 3.08 / 485.32 2 4
6 13 153.88 21 15.15 533 170 3.25 / 485.49 2 3
7 13 39.36 21 15.17 368 117 3.37 / 485.60 2 3
8 8 -0.08 175 15.14 302 800 4.17 / 486.40 2 9
Average= 4.09
(KJ/cycle)

Cycle 117 GMT 10/ 3/2022 4:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.00 34 15.11 427 219 0.22 / 478.31 2 2
2 12 1191.52 4 15.31 2047 125 0.34 / 478.43 2 2
3 7 2001.72 32 14.89 2996 1428 1.77 / 479.86 2 4
4 13 1497.96 21 14.90 2382 745 2.52 / 480.61 2 4
5 13 980.08 21 14.96 1708 537 3.05 / 481.14 2 3
6 13 158.48 21 15.15 551 175 3.23 / 481.32 2 3
7 13 49.48 21 15.17 385 123 3.35 / 481.44 2 3
8 8 0.12 175 15.15 299 793 4.14 / 482.23 2 8
Average= 4.09
(KJ/cycle)

Cycle 116 GMT 28/ 2/2022 5:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.72 34 15.10 460 236 0.24 / 474.11 2 2
2 12 1187.52 4 15.31 2033 125 0.36 / 474.23 2 2
3 7 2003.20 32 14.90 3007 1434 1.79 / 475.66 2 3
4 13 1506.76 21 14.91 2400 751 2.55 / 476.41 2 4
5 13 985.92 21 14.96 1711 538 3.08 / 476.95 2 5
6 13 253.56 21 15.13 680 216 3.30 / 477.17 2 3
7 13 52.12 21 15.17 390 124 3.42 / 477.29 2 3
8 8 0.16 175 15.15 300 795 4.22 / 478.09 2 5
Average= 4.09
(KJ/cycle)

Cycle 115 GMT 18/ 2/2022 7:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.12 34 15.12 455 234 0.23 / 469.91 2 2
2 12 1181.40 4 15.31 2048 125 0.36 / 470.04 2 2
3 7 2001.68 32 14.90 3013 1437 1.80 / 471.47 2 4
4 13 1506.92 21 14.91 2397 751 2.55 / 472.22 2 3
5 13 994.32 21 14.96 1721 541 3.09 / 472.77 2 4
6 13 153.04 21 15.15 538 171 3.26 / 472.94 2 3
7 13 31.80 21 15.18 366 117 3.37 / 473.05 2 3
8 8 -0.04 175 15.14 308 816 4.19 / 473.87 2 8
Average= 4.09
(KJ/cycle)

Cycle 114 GMT 8/ 2/2022 8:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.68 34 15.11 467 240 0.24 / 465.72 2 2
2 12 1179.08 4 15.32 2044 125 0.37 / 465.85 2 2
3 7 2001.60 32 14.89 3009 1434 1.80 / 467.28 2 4
4 13 1503.96 21 14.91 2398 751 2.55 / 468.03 2 4
5 13 977.60 21 14.96 1704 535 3.09 / 468.57 2 3
6 13 142.16 21 15.16 531 169 3.25 / 468.74 2 3
7 13 34.76 21 15.18 374 119 3.37 / 468.86 2 3
8 8 0.04 175 15.15 310 822 4.20 / 469.68 2 9
Average= 4.08
(KJ/cycle)

Cycle 113 GMT 29/ 1/2022 10:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.88 34 15.12 460 236 0.24 / 461.50 2 2
2 12 1177.36 4 15.32 2014 123 0.36 / 461.63 2 3
3 7 2003.56 32 14.90 3012 1436 1.80 / 463.06 2 3
4 13 1515.44 21 14.90 2414 755 2.55 / 463.82 2 4
5 13 1000.76 21 14.96 1733 544 3.10 / 464.36 2 4
6 13 157.20 21 15.16 549 175 3.27 / 464.54 2 3
7 13 32.68 21 15.18 372 119 3.39 / 464.66 2 3
8 8 -0.04 175 15.15 312 827 4.22 / 465.48 2 6
Average= 4.08
(KJ/cycle)

Cycle 112 GMT 19/ 1/2022 12:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.28 34 15.12 451 232 0.23 / 457.24 2 2
2 12 1192.56 4 15.31 2049 125 0.36 / 457.36 2 3
3 7 2000.96 32 14.89 3005 1432 1.79 / 458.79 2 5
4 13 1503.08 21 14.91 2396 750 2.54 / 459.54 2 4
5 13 965.96 21 14.97 1693 532 3.07 / 460.07 2 4
6 13 131.64 21 15.17 516 164 3.24 / 460.24 2 3
7 13 27.64 21 15.19 358 114 3.35 / 460.35 2 3
8 8 -0.04 175 15.16 309 820 4.17 / 461.17 2 7
9 14 -0.04 20 15.13 308 93 4.26 / 461.27 2 9
Average= 4.08
(KJ/cycle)

Cycle 111 GMT 9/ 1/2022 14:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.72 33 15.13 463 231 0.23 / 452.95 2 2
2 12 1187.40 4 15.32 2056 126 0.36 / 453.08 2 2
3 7 2003.72 33 14.90 3015 1482 1.84 / 454.56 2 4
4 13 1505.64 21 14.91 2392 749 2.59 / 455.31 2 4
5 13 979.40 21 14.97 1704 536 3.12 / 455.84 2 4
6 13 244.36 21 15.14 677 215 3.34 / 456.06 2 3
7 13 20.08 21 15.19 357 114 3.45 / 456.17 2 3
8 8 0.04 175 15.16 313 830 4.28 / 457.00 2 6
Average= 4.08
(KJ/cycle)

Cycle 110 GMT 30/12/2021 16: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.60 33 15.11 464 231 0.23 / 448.93 2 2
2 12 1171.56 4 15.31 2050 126 0.36 / 449.05 2 3
3 7 2002.32 32 14.90 3014 1437 1.79 / 450.49 2 3
4 13 1507.00 21 14.91 2406 753 2.55 / 451.24 2 4
5 13 859.00 21 15.00 1534 483 3.03 / 451.72 2 5
6 13 163.80 21 15.17 549 175 3.21 / 451.90 2 3
7 8 -0.04 175 15.17 309 820 4.03 / 452.72 2 6
Average= 4.08
(KJ/cycle)

Cycle 109 GMT 20/12/2021 17:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.24 34 15.12 464 239 0.24 / 444.64 2 2
2 12 1171.88 4 15.31 2033 125 0.36 / 444.76 2 2
3 7 2002.52 32 14.90 3021 1440 1.80 / 446.20 2 3
4 13 1661.76 21 14.89 2608 815 2.62 / 447.02 2 3
5 13 955.72 21 14.97 1680 528 3.15 / 447.55 2 5
6 13 233.92 21 15.15 657 209 3.36 / 447.76 2 3
7 13 20.20 21 15.20 352 112 3.47 / 447.87 2 3
8 8 0.04 175 15.16 311 825 4.29 / 448.69 2 8
Average= 4.08
(KJ/cycle)

Cycle 108 GMT 10/12/2021 18:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.40 34 15.13 465 239 0.24 / 440.51 2 2
2 12 1179.00 4 15.31 2031 124 0.36 / 440.64 2 2
3 7 2002.24 32 14.91 3021 1441 1.80 / 442.08 2 4
4 13 1493.52 21 14.92 2382 746 2.55 / 442.82 2 4
5 13 980.08 21 14.98 1695 533 3.08 / 443.36 2 5
6 13 233.24 21 15.15 654 208 3.29 / 443.56 2 3
7 8 0.08 175 15.17 315 836 4.13 / 444.40 2 7
Average= 4.08
(KJ/cycle)

Cycle 107 GMT 30/11/2021 20:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.84 34 15.14 463 238 0.24 / 436.48 2 2
2 12 1189.44 4 15.31 2060 126 0.36 / 436.61 2 2
3 7 2001.96 32 14.90 3006 1433 1.80 / 438.04 2 3
4 13 1506.92 21 14.92 2393 750 2.55 / 438.79 2 4
5 13 852.36 21 15.01 1532 483 3.03 / 439.27 2 4
6 13 167.24 21 15.17 555 177 3.21 / 439.45 2 3
7 8 0.12 175 15.17 310 823 4.03 / 440.27 2 6
Average= 4.08
(KJ/cycle)

Cycle 106 GMT 20/11/2021 22:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.64 34 15.13 470 242 0.24 / 432.37 2 2
2 12 1176.08 4 15.32 2037 125 0.37 / 432.49 2 2
3 7 2002.96 32 14.91 3003 1433 1.80 / 433.93 2 5
4 13 1512.84 21 14.92 2404 753 2.55 / 434.68 2 3
5 13 1006.48 21 14.96 1741 547 3.10 / 435.23 2 5
6 13 154.48 21 15.18 551 176 3.28 / 435.40 2 3
7 8 0.16 175 15.18 316 839 4.11 / 436.24 2 7
Average= 4.08
(KJ/cycle)

Cycle 105 GMT 10/11/2021 23:34: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.92 34 15.14 468 241 0.24 / 428.21 2 2
2 12 1175.40 4 15.32 2042 125 0.37 / 428.34 2 2
3 7 2006.44 32 14.89 3024 1441 1.81 / 429.78 2 5
4 13 1512.44 21 14.92 2412 756 2.56 / 430.53 2 3
5 13 976.92 21 14.97 1700 534 3.10 / 431.07 2 5
6 13 251.16 21 15.15 688 219 3.32 / 431.29 2 3
7 8 -0.04 175 15.17 316 839 4.15 / 432.13 2 8
Average= 4.08
(KJ/cycle)

Cycle 104 GMT 1/11/2021 0: 6: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.04 34 15.14 465 239 0.24 / 424.11 2 2
2 12 1173.00 4 15.33 2042 125 0.36 / 424.24 2 2
3 7 2002.96 32 14.90 3015 1438 1.80 / 425.68 2 3
4 13 1509.48 21 14.91 2413 756 2.56 / 426.43 2 4
5 13 982.52 21 14.98 1712 539 3.10 / 426.97 2 5
6 13 144.84 21 15.19 526 168 3.26 / 427.14 2 3
7 8 0.20 175 15.18 314 834 4.10 / 427.97 2 6
Average= 4.08
(KJ/cycle)

Cycle 103 GMT 22/10/2021 1:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.44 34 15.14 470 242 0.24 / 420.09 2 2
2 12 1187.12 4 15.33 2044 125 0.37 / 420.22 2 2
3 7 2002.32 32 14.90 3025 1442 1.81 / 421.66 2 5
4 13 1371.52 21 14.94 2236 702 2.51 / 422.36 2 3
5 13 886.56 21 14.99 1596 502 3.01 / 422.86 2 4
6 13 166.68 21 15.18 562 179 3.19 / 423.04 2 3
7 8 -0.12 175 15.18 313 831 4.02 / 423.87 2 7
Average= 4.08
(KJ/cycle)

Cycle 102 GMT 12/10/2021 2:42: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.64 34 15.14 469 241 0.24 / 416.07 2 2
2 12 1184.04 4 15.32 2041 125 0.37 / 416.19 2 2
3 7 2002.52 32 14.90 3014 1437 1.80 / 417.63 2 4
4 13 1491.92 21 14.92 2389 749 2.55 / 418.38 2 4
5 13 817.96 21 15.03 1483 468 3.02 / 418.85 2 4
6 13 139.76 21 15.19 522 167 3.19 / 419.01 2 3
7 8 0.16 175 15.18 315 837 4.02 / 419.85 2 6
Average= 4.08
(KJ/cycle)

Cycle 101 GMT 2/10/2021 4:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.48 34 15.14 459 236 0.24 / 411.96 2 2
2 12 1175.36 4 15.33 2044 125 0.36 / 412.09 2 2
3 7 2003.12 32 14.90 3016 1438 1.80 / 413.53 2 3
4 13 1506.52 21 14.92 2409 755 2.55 / 414.28 2 3
5 13 985.52 21 14.98 1716 540 3.09 / 414.82 2 4
6 13 140.76 21 15.19 532 170 3.26 / 414.99 2 3
7 8 0.12 175 15.19 314 835 4.10 / 415.83 2 6
Average= 4.08
(KJ/cycle)

Cycle 100 GMT 22/ 9/2021 5:26: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.44 34 15.13 463 238 0.24 / 407.98 2 2
2 12 1178.92 4 15.34 2044 125 0.36 / 408.11 2 3
3 7 2005.76 32 14.90 3016 1438 1.80 / 409.55 2 2
4 13 1369.68 21 14.94 2233 701 2.50 / 410.25 2 3
5 13 883.72 21 15.00 1577 497 3.00 / 410.75 2 4
6 13 92.16 21 15.20 455 145 3.14 / 410.89 2 3
7 8 0.04 175 15.18 315 837 3.98 / 411.73 2 8
Average= 4.08
(KJ/cycle)

Cycle 99 GMT 12/ 9/2021 6:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.20 34 15.14 460 237 0.24 / 403.82 2 2
2 12 1185.52 4 15.33 2049 126 0.36 / 403.94 2 2
3 7 2003.04 32 14.91 3019 1440 1.80 / 405.38 2 5
4 13 1515.24 21 14.92 2418 758 2.56 / 406.14 2 4
5 13 993.64 21 14.98 1722 542 3.10 / 406.68 2 5
6 13 247.80 21 15.16 669 213 3.32 / 406.90 2 3
7 8 0.16 175 15.18 320 850 4.17 / 407.75 2 6
Average= 4.08
(KJ/cycle)

Cycle 98 GMT 2/ 9/2021 8:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.48 33 15.14 470 235 0.23 / 399.81 2 2
2 12 1180.04 4 15.34 2036 125 0.36 / 399.93 2 2
3 7 2002.40 32 14.91 3012 1437 1.80 / 401.37 2 2
4 13 1500.44 21 14.93 2395 751 2.55 / 402.12 2 4
5 13 859.64 21 15.02 1534 484 3.03 / 402.61 2 4
6 13 99.60 21 15.20 467 149 3.18 / 402.75 2 3
7 8 0.12 175 15.18 311 826 4.01 / 403.58 2 6
Average= 4.08
(KJ/cycle)

Cycle 97 GMT 23/ 8/2021 9:56: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.36 33 15.15 465 232 0.23 / 395.73 2 2
2 12 1180.28 4 15.34 2040 125 0.36 / 395.85 2 3
3 7 2002.84 32 14.91 3000 1431 1.79 / 397.29 2 3
4 13 1499.84 21 14.93 2386 748 2.54 / 398.03 2 3
5 13 985.48 21 14.99 1709 538 3.08 / 398.57 2 3
6 13 136.32 21 15.19 521 166 3.24 / 398.74 2 3
7 8 0.08 175 15.18 315 837 4.08 / 399.57 2 6
Average= 4.08
(KJ/cycle)

Cycle 96 GMT 13/ 8/2021 11:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.56 33 15.15 464 232 0.23 / 391.64 2 2
2 12 1183.04 4 15.34 2046 126 0.36 / 391.77 2 2
3 7 2003.16 32 14.92 3014 1439 1.80 / 393.21 2 4
4 13 1506.08 21 14.93 2400 752 2.55 / 393.96 2 4
5 13 982.52 21 14.99 1708 538 3.09 / 394.50 2 4
6 13 145.92 21 15.20 529 169 3.26 / 394.67 2 3
7 8 -0.12 175 15.19 312 829 4.08 / 395.50 2 9
Average= 4.08
(KJ/cycle)

Cycle 95 GMT 3/ 8/2021 12:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.28 33 15.14 447 223 0.22 / 387.56 2 2
2 12 1172.16 4 15.34 2018 124 0.35 / 387.68 2 2
3 7 2002.64 32 14.92 3007 1436 1.78 / 389.12 2 2
4 13 1496.16 21 14.94 2395 751 2.53 / 389.87 2 3
5 13 990.52 21 14.99 1720 541 3.08 / 390.41 2 4
6 13 137.88 21 15.20 519 166 3.24 / 390.57 2 3
7 8 0.12 175 15.19 315 837 4.08 / 391.41 2 6
Average= 4.08
(KJ/cycle)

Cycle 94 GMT 24/ 7/2021 14:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.16 33 15.15 467 233 0.23 / 383.42 2 2
2 12 1175.16 4 15.35 2036 125 0.36 / 383.55 2 2
3 7 2005.28 32 14.92 3008 1436 1.79 / 384.98 2 3
4 13 1498.68 21 14.94 2394 751 2.55 / 385.74 2 3
5 13 974.44 21 15.00 1702 536 3.08 / 386.27 2 5
6 13 259.24 21 15.17 695 221 3.30 / 386.49 2 3
7 8 0.00 175 15.19 316 840 4.14 / 387.33 2 6
Average= 4.08
(KJ/cycle)

Cycle 93 GMT 14/ 7/2021 15:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.36 33 15.16 473 237 0.24 / 379.36 2 2
2 12 1189.20 4 15.34 2051 126 0.36 / 379.49 2 2
3 7 2001.68 32 14.92 3018 1441 1.80 / 380.93 2 3
4 13 1508.80 21 14.94 2413 757 2.56 / 381.69 2 4
5 13 856.00 21 15.03 1538 485 3.05 / 382.17 2 4
6 13 154.52 21 15.21 547 175 3.22 / 382.35 2 3
7 8 0.04 175 15.20 316 841 4.06 / 383.19 2 11
Average= 4.08
(KJ/cycle)

Cycle 92 GMT 4/ 7/2021 17: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.44 33 15.16 460 230 0.23 / 375.24 2 2
2 12 1185.40 4 15.34 2052 126 0.36 / 375.36 2 2
3 7 2002.36 32 14.91 3020 1441 1.80 / 376.80 2 4
4 13 1507.36 23 14.93 2405 826 2.62 / 377.63 2 3
5 13 813.16 23 15.03 1483 513 3.14 / 378.14 2 4
6 13 69.28 23 15.23 424 149 3.28 / 378.29 2 3
7 8 0.00 175 15.20 315 838 4.12 / 379.13 2 5
Average= 4.08
(KJ/cycle)

Cycle 91 GMT 24/ 6/2021 18:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.00 33 15.16 475 238 0.24 / 371.12 2 2
2 12 1171.12 4 15.35 2040 125 0.36 / 371.24 2 2
3 7 2001.76 32 14.93 3013 1439 1.80 / 372.68 2 3
4 13 1519.80 23 14.93 2421 831 2.63 / 373.51 2 4
5 13 828.40 23 15.03 1495 517 3.15 / 374.03 2 4
6 13 43.40 23 15.24 386 135 3.29 / 374.17 2 3
7 8 0.12 175 15.21 316 841 4.13 / 375.01 2 8
Average= 4.08
(KJ/cycle)

Cycle 90 GMT 14/ 6/2021 20: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.12 33 15.17 472 236 0.24 / 367.04 2 2
2 12 1162.64 4 15.35 2020 124 0.36 / 367.17 2 3
3 7 2003.80 33 14.92 3006 1480 1.84 / 368.65 2 4
4 13 1370.32 23 14.95 2225 765 2.61 / 369.41 2 3
5 13 709.88 23 15.07 1331 461 3.07 / 369.87 2 4
6 13 78.48 23 15.23 440 154 3.22 / 370.03 2 3
7 8 0.00 175 15.20 320 851 4.07 / 370.88 2 9
Average= 4.08
(KJ/cycle)

Cycle 89 GMT 4/ 6/2021 21:34: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.44 33 15.17 466 233 0.23 / 362.88 2 2
2 12 1176.52 4 15.35 2041 125 0.36 / 363.00 2 2
3 7 2006.48 32 14.92 3026 1445 1.80 / 364.45 2 4
4 13 1511.96 23 14.93 2418 830 2.63 / 365.28 2 4
5 13 827.36 23 15.04 1503 520 3.15 / 365.80 2 5
6 13 76.24 23 15.23 440 154 3.31 / 365.95 2 3
7 8 -0.08 175 15.21 321 854 4.16 / 366.81 2 4
Average= 4.08
(KJ/cycle)

Cycle 88 GMT 25/ 5/2021 22:11: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.76 33 15.18 451 226 0.23 / 358.73 2 2
2 12 1174.36 4 15.35 2052 126 0.35 / 358.86 2 3
3 7 2004.04 32 14.92 3009 1437 1.79 / 360.29 2 4
4 13 1505.00 23 14.94 2396 823 2.61 / 361.12 2 3
5 13 822.96 23 15.04 1489 515 3.13 / 361.63 2 4
6 13 114.76 23 15.22 490 172 3.30 / 361.80 2 3
7 8 0.00 175 15.21 316 841 4.14 / 362.65 2 5
Average= 4.07
(KJ/cycle)

Cycle 87 GMT 15/ 5/2021 23:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.16 33 15.17 467 234 0.23 / 354.60 2 2
2 12 1182.48 4 15.35 2065 127 0.36 / 354.72 2 2
3 7 2002.72 32 14.94 3020 1444 1.80 / 356.17 2 3
4 13 1495.28 23 14.94 2393 822 2.63 / 356.99 2 4
5 13 822.32 23 15.05 1487 515 3.14 / 357.50 2 4
6 13 112.16 23 15.23 486 170 3.31 / 357.67 2 3
7 8 0.12 175 15.22 312 831 4.14 / 358.51 2 9
Average= 4.07
(KJ/cycle)

Cycle 86 GMT 6/ 5/2021 1: 7: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.48 33 15.18 447 224 0.22 / 350.28 2 2
2 12 1174.56 4 15.35 2041 125 0.35 / 350.40 2 2
3 7 2007.84 32 14.92 3030 1447 1.80 / 351.85 2 3
4 13 1522.24 23 14.93 2430 834 2.63 / 352.68 2 4
5 13 974.32 23 15.00 1693 584 3.21 / 353.27 2 4
6 13 97.32 23 15.23 465 163 3.38 / 353.43 2 3
7 8 0.00 175 15.22 314 836 4.21 / 354.27 2 8
8 14 0.00 20 15.19 320 97 4.31 / 354.36 2 9
Average= 4.07
(KJ/cycle)

Cycle 85 GMT 26/ 4/2021 2:10: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.52 33 15.18 454 227 0.23 / 346.15 2 2
2 12 1181.60 4 15.35 2044 126 0.35 / 346.28 2 2
3 7 2001.84 32 14.94 3017 1442 1.80 / 347.72 2 4
4 13 1519.40 23 14.94 2424 833 2.63 / 348.55 2 4
5 13 832.00 23 15.05 1502 520 3.15 / 349.07 2 4
6 13 72.96 23 15.24 430 151 3.30 / 349.22 2 3
7 8 0.08 175 15.22 312 831 4.13 / 350.05 2 9
Average= 4.07
(KJ/cycle)

Cycle 84 GMT 16/ 4/2021 3:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.08 33 15.18 451 226 0.23 / 341.89 2 2
2 12 1183.08 4 15.36 2034 125 0.35 / 342.01 2 2
3 7 2002.00 32 14.94 3014 1441 1.79 / 343.45 2 3
4 13 1496.44 22 14.96 2390 787 2.58 / 344.24 2 4
5 13 971.76 22 15.02 1695 560 3.14 / 344.80 2 4
6 13 121.88 22 15.24 495 166 3.30 / 344.97 2 3
7 13 26.08 22 15.25 365 122 3.43 / 345.09 2 3
8 8 0.00 175 15.22 313 834 4.26 / 345.92 2 9
Average= 4.07
(KJ/cycle)

Cycle 83 GMT 6/ 4/2021 5:20: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.44 33 15.19 463 232 0.23 / 337.57 2 2
2 12 1190.52 4 15.35 2058 126 0.36 / 337.70 2 3
3 7 2001.12 32 14.93 3015 1440 1.80 / 339.14 2 4
4 13 1503.04 22 14.96 2404 791 2.59 / 339.93 2 3
5 13 962.96 22 15.02 1685 557 3.15 / 340.49 2 4
6 13 219.56 22 15.21 638 213 3.36 / 340.70 2 3
7 13 29.12 22 15.25 368 123 3.48 / 340.82 2 3
8 8 -0.04 175 15.22 315 839 4.32 / 341.66 2 8
Average= 4.07
(KJ/cycle)

Cycle 82 GMT 27/ 3/2021 7: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.80 33 15.19 466 234 0.23 / 333.40 2 2
2 12 1171.24 4 15.36 2039 125 0.36 / 333.53 2 2
3 7 2000.92 32 14.93 3012 1439 1.80 / 334.97 2 3
4 13 1500.80 21 14.95 2406 755 2.55 / 335.72 2 4
5 13 841.40 21 15.06 1518 480 3.03 / 336.20 2 4
6 13 152.96 21 15.23 550 176 3.21 / 336.38 2 3
7 13 28.36 21 15.25 366 117 3.33 / 336.49 2 3
8 8 -0.08 175 15.22 317 844 4.17 / 337.34 2 9
Average= 4.06
(KJ/cycle)

Cycle 81 GMT 17/ 3/2021 8:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.04 33 15.20 460 231 0.23 / 329.22 2 2
2 12 1173.20 4 15.37 2028 125 0.36 / 329.34 2 3
3 7 2004.24 32 14.94 3020 1444 1.80 / 330.79 2 3
4 13 1506.76 21 14.96 2411 757 2.56 / 331.55 2 3
5 13 859.64 21 15.06 1541 487 3.04 / 332.03 2 3
6 13 151.92 21 15.24 546 175 3.22 / 332.21 2 3
7 13 34.44 21 15.26 375 120 3.34 / 332.33 2 3
8 8 0.16 175 15.23 315 840 4.18 / 333.17 2 8
Average= 4.06
(KJ/cycle)

Cycle 80 GMT 7/ 3/2021 9:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.96 33 15.20 458 230 0.23 / 325.03 2 2
2 12 1174.00 4 15.37 2031 125 0.35 / 325.16 2 2
3 7 2000.64 32 14.95 3030 1450 1.80 / 326.61 2 4
4 13 1498.28 21 14.96 2407 756 2.56 / 327.36 2 3
5 13 962.08 21 15.03 1686 532 3.09 / 327.90 2 5
6 13 81.48 21 15.27 443 142 3.23 / 328.04 2 3
7 13 20.00 21 15.27 352 113 3.35 / 328.15 2 3
8 8 -0.12 175 15.24 314 837 4.18 / 328.99 2 10
Average= 4.06
(KJ/cycle)

Cycle 79 GMT 25/ 2/2021 11: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.88 33 15.21 454 228 0.23 / 320.84 2 2
2 12 1179.68 4 15.37 2048 126 0.35 / 320.97 2 3
3 7 2001.52 32 14.93 3029 1447 1.80 / 322.41 2 3
4 13 1497.60 21 14.96 2399 754 2.55 / 323.17 2 4
5 13 960.00 21 15.03 1694 535 3.09 / 323.70 2 4
6 13 81.84 21 15.27 450 144 3.23 / 323.85 2 3
7 13 18.44 21 15.28 355 114 3.35 / 323.96 2 3
8 8 -0.24 175 15.24 317 845 4.19 / 324.80 2 8
Average= 4.06
(KJ/cycle)

Cycle 78 GMT 15/ 2/2021 12:40: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.84 33 15.22 474 238 0.24 / 316.58 2 2
2 12 1158.08 4 15.37 2024 124 0.36 / 316.70 2 3
3 7 2001.48 33 14.93 3026 1491 1.85 / 318.19 2 3
4 13 1493.52 21 14.96 2393 752 2.61 / 318.95 2 4
5 13 966.20 21 15.03 1701 537 3.14 / 319.48 2 6
6 13 129.48 21 15.25 521 167 3.31 / 319.65 2 3
7 13 23.32 21 15.28 366 117 3.43 / 319.77 2 3
8 8 -0.04 175 15.24 317 845 4.27 / 320.61 2 8
Average= 4.06
(KJ/cycle)

Cycle 77 GMT 5/ 2/2021 13:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.36 33 15.22 455 229 0.23 / 312.47 2 2
2 12 1177.40 4 15.38 2031 125 0.35 / 312.60 2 3
3 7 2000.60 32 14.94 3026 1447 1.80 / 314.04 2 3
4 13 1490.52 21 14.97 2389 751 2.55 / 314.79 2 4
5 13 963.72 21 15.03 1698 536 3.09 / 315.33 2 4
6 13 123.44 21 15.27 502 161 3.25 / 315.49 2 3
7 8 0.08 175 15.26 318 849 4.10 / 316.34 2 8
Average= 4.06
(KJ/cycle)

Cycle 76 GMT 26/ 1/2021 14:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.20 33 15.23 460 231 0.23 / 308.37 2 2
2 12 1182.60 4 15.36 2072 127 0.36 / 308.50 2 3
3 7 2000.64 32 14.95 3019 1444 1.80 / 309.94 2 2
4 13 1511.40 19 14.98 2417 688 2.49 / 310.63 2 4
5 13 994.76 19 15.05 1734 496 2.99 / 311.12 2 5
6 13 165.04 19 15.27 565 164 3.15 / 311.29 2 3
7 13 34.16 19 15.30 378 110 3.26 / 311.40 2 3
8 8 -0.04 175 15.27 316 844 4.10 / 312.24 2 10
Average= 4.06
(KJ/cycle)

Cycle 75 GMT 16/ 1/2021 15:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.28 33 15.24 465 234 0.23 / 304.18 2 2
2 12 1184.48 4 15.37 2053 126 0.36 / 304.31 2 2
3 7 2003.32 33 14.94 3019 1488 1.85 / 305.80 2 3
4 13 1508.92 19 14.97 2419 688 2.54 / 306.49 2 4
5 13 971.64 19 15.05 1701 486 3.02 / 306.97 2 6
6 13 282.24 19 15.24 725 210 3.23 / 307.18 2 3
7 13 24.04 19 15.30 366 106 3.34 / 307.29 2 3
8 8 0.04 175 15.27 318 850 4.19 / 308.14 2 10
Average= 4.05
(KJ/cycle)

Cycle 74 GMT 6/ 1/2021 16:11: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.00 33 15.24 466 234 0.23 / 300.13 2 2
2 12 1173.44 4 15.38 2040 126 0.36 / 300.26 2 2
3 7 1997.88 32 14.95 3015 1442 1.80 / 301.70 2 4
4 13 1502.60 19 14.98 2412 687 2.49 / 302.39 2 4
5 13 989.88 19 15.05 1729 494 2.98 / 302.88 2 4
6 13 285.00 19 15.24 728 211 3.19 / 303.09 2 3
7 8 0.12 175 15.28 320 856 4.05 / 303.95 2 9
Average= 4.05
(KJ/cycle)

Cycle 73 GMT 27/12/2020 15:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.32 33 15.24 456 229 0.23 / 296.08 2 2
2 12 1174.84 4 15.37 2046 126 0.36 / 296.20 2 2
3 7 1998.04 32 14.94 3024 1446 1.80 / 297.65 2 3
4 13 1485.52 19 14.99 2390 681 2.48 / 298.33 2 5
5 13 985.12 19 15.05 1726 494 2.98 / 298.82 2 4
6 13 295.48 19 15.24 756 219 3.19 / 299.04 2 4
7 8 0.04 175 15.28 321 858 4.05 / 299.90 2 7
Average= 4.05
(KJ/cycle)

Cycle 72 GMT 17/12/2020 14:42: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.52 33 15.25 458 230 0.23 / 292.01 2 2
2 12 1182.76 4 15.37 2048 126 0.36 / 292.13 2 3
3 7 1999.28 33 14.94 3028 1493 1.85 / 293.62 2 3
4 13 1357.84 19 15.01 2223 634 2.48 / 294.26 2 4
5 13 1032.08 19 15.03 1790 511 2.99 / 294.77 2 4
6 13 303.16 19 15.24 764 221 3.22 / 294.99 2 3
7 8 0.12 175 15.28 320 856 4.07 / 295.85 2 7
Average= 4.05
(KJ/cycle)

Cycle 71 GMT 7/12/2020 13:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.56 33 15.25 469 236 0.24 / 287.95 2 2
2 12 1179.84 4 15.37 2060 127 0.36 / 288.07 2 2
3 7 2001.20 32 14.96 3019 1445 1.81 / 289.52 2 4
4 13 1515.28 19 14.99 2410 686 2.49 / 290.21 2 4
5 13 992.40 19 15.06 1732 496 2.99 / 290.70 2 5
6 13 288.72 19 15.26 735 213 3.20 / 290.91 2 3
7 8 0.04 175 15.29 322 862 4.06 / 291.78 2 6
Average= 4.05
(KJ/cycle)

Cycle 70 GMT 27/11/2020 15:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.88 33 15.25 462 233 0.23 / 283.89 2 2
2 12 1176.80 4 15.38 2031 125 0.36 / 284.01 2 2
3 7 2006.20 32 14.96 3032 1451 1.81 / 285.46 2 4
4 13 1483.40 19 15.00 2375 677 2.49 / 286.14 2 4
5 13 978.80 19 15.07 1714 491 2.98 / 286.63 2 5
6 13 294.84 19 15.26 746 216 3.19 / 286.85 2 3
7 8 0.24 175 15.30 322 862 4.06 / 287.71 2 6
Average= 4.05
(KJ/cycle)

Cycle 69 GMT 17/11/2020 15:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.60 33 15.25 458 230 0.23 / 279.89 2 2
2 12 1153.12 4 15.38 2013 124 0.35 / 280.01 2 3
3 7 2001.80 32 14.96 3025 1448 1.80 / 281.46 2 4
4 13 1506.72 19 15.00 2410 687 2.49 / 282.15 2 3
5 13 986.92 19 15.07 1726 494 2.98 / 282.64 2 4
6 13 153.68 19 15.30 545 158 3.14 / 282.80 2 3
7 8 0.20 175 15.30 319 854 4.00 / 283.66 2 7
Average= 4.05
(KJ/cycle)

Cycle 68 GMT 7/11/2020 15:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.40 33 15.25 480 242 0.24 / 275.67 2 2
2 12 1180.80 4 15.40 2038 126 0.37 / 275.80 2 3
3 7 2005.44 33 14.97 3012 1488 1.86 / 277.29 2 3
4 13 1525.44 19 14.99 2434 693 2.55 / 277.98 2 3
5 13 1142.56 19 15.03 1920 548 3.10 / 278.53 2 3
6 13 416.72 19 15.23 918 266 3.36 / 278.80 2 4
7 8 0.00 175 15.29 323 864 4.23 / 279.66 2 9
Average= 4.05
(KJ/cycle)

Cycle 67 GMT 28/10/2020 17:10: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.72 33 15.27 478 241 0.24 / 271.56 2 2
2 12 1176.92 4 15.40 2028 125 0.37 / 271.69 2 3
3 7 2000.20 33 14.97 3012 1488 1.85 / 273.18 2 3
4 13 1509.08 19 15.00 2403 685 2.54 / 273.86 2 3
5 13 988.04 19 15.07 1721 493 3.03 / 274.36 2 5
6 13 295.56 19 15.27 744 216 3.25 / 274.57 2 3
7 8 0.12 175 15.30 322 862 4.11 / 275.43 2 5
Average= 4.05
(KJ/cycle)

Cycle 66 GMT 18/10/2020 18:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.68 33 15.26 472 238 0.24 / 267.53 2 2
2 12 1189.12 4 15.40 2078 128 0.37 / 267.66 2 3
3 7 2000.96 32 14.97 3023 1448 1.81 / 269.10 2 4
4 13 1482.56 19 15.02 2376 678 2.49 / 269.78 2 4
5 13 963.20 19 15.09 1682 482 2.97 / 270.26 2 4
6 13 254.24 19 15.28 690 200 3.17 / 270.46 2 3
7 8 0.08 175 15.31 321 860 4.03 / 271.32 2 8
Average= 4.05
(KJ/cycle)

Cycle 65 GMT 8/10/2020 19:51:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.04 33 15.27 476 240 0.24 / 263.38 2 2
2 12 1189.92 4 15.39 2076 128 0.37 / 263.51 2 3
3 7 2008.60 32 14.98 3028 1452 1.82 / 264.96 2 3
4 13 1503.40 20 15.01 2406 722 2.54 / 265.69 2 5
5 13 992.32 20 15.08 1722 519 3.06 / 266.21 2 4
6 13 279.92 20 15.28 723 221 3.28 / 266.43 2 3
7 8 0.08 175 15.31 322 863 4.14 / 267.29 2 9
Average= 4.05
(KJ/cycle)

Cycle 64 GMT 28/ 9/2020 20:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.60 33 15.27 471 237 0.24 / 259.34 2 2
2 12 1181.24 4 15.40 2030 125 0.36 / 259.47 2 3
3 7 2002.32 32 14.99 3005 1441 1.80 / 260.91 2 3
4 13 1515.72 20 15.01 2415 725 2.53 / 261.64 2 3
5 13 879.44 20 15.12 1571 475 3.00 / 262.11 2 4
6 13 177.28 20 15.31 584 179 3.18 / 262.29 2 3
7 8 0.08 175 15.31 319 855 4.04 / 263.14 2 7
Average= 4.05
(KJ/cycle)

Cycle 63 GMT 18/ 9/2020 22:23:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.72 33 15.28 471 237 0.24 / 255.28 2 2
2 12 1184.80 4 15.41 2034 125 0.36 / 255.40 2 2
3 7 2001.88 32 14.98 3015 1445 1.81 / 256.85 2 3
4 13 1500.04 20 15.01 2398 720 2.53 / 257.57 2 3
5 13 983.56 20 15.09 1719 519 3.05 / 258.09 2 5
6 13 145.60 20 15.33 535 164 3.21 / 258.25 2 3
7 8 -0.04 175 15.32 319 855 4.07 / 259.11 2 9
Average= 4.05
(KJ/cycle)

Cycle 62 GMT 9/ 9/2020 0: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.72 33 15.28 466 235 0.23 / 251.15 2 2
2 12 1184.80 4 15.41 2051 126 0.36 / 251.27 2 3
3 7 2003.08 32 14.99 3012 1445 1.81 / 252.72 2 4
4 13 1520.40 20 15.01 2417 726 2.53 / 253.45 2 3
5 13 989.28 20 15.09 1723 520 3.05 / 253.97 2 5
6 13 254.08 20 15.30 687 210 3.26 / 254.18 2 3
7 8 0.20 175 15.32 323 866 4.13 / 255.04 2 8
Average= 4.05
(KJ/cycle)

Cycle 61 GMT 30/ 8/2020 0:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.12 33 15.29 465 235 0.23 / 247.03 2 2
2 12 1189.48 4 15.40 2063 127 0.36 / 247.16 2 3
3 7 2001.64 34 14.98 3001 1528 1.89 / 248.69 2 5
4 13 1478.16 20 15.03 2357 709 2.60 / 249.40 2 3
5 13 951.96 20 15.11 1673 506 3.10 / 249.90 2 4
6 13 108.12 20 15.35 486 149 3.25 / 250.05 2 3
7 8 0.12 175 15.33 321 861 4.11 / 250.91 2 8
Average= 4.05
(KJ/cycle)

Cycle 60 GMT 20/ 8/2020 2:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.60 33 15.30 473 239 0.24 / 242.86 2 2
2 12 1181.92 4 15.41 2055 127 0.37 / 242.98 2 3
3 7 2003.60 34 14.97 3016 1535 1.90 / 244.52 2 2
4 13 1486.12 20 15.02 2382 716 2.62 / 245.23 2 3
5 13 960.40 20 15.11 1679 507 3.12 / 245.74 2 4
6 13 217.76 20 15.32 640 196 3.32 / 245.94 2 3
7 8 0.08 175 15.33 321 861 4.18 / 246.80 2 9
Average= 4.05
(KJ/cycle)

Cycle 59 GMT 10/ 8/2020 3:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.48 33 15.29 469 237 0.24 / 238.70 2 2
2 12 1192.40 4 15.41 2080 128 0.36 / 238.83 2 2
3 7 2001.12 34 14.98 3013 1535 1.90 / 240.37 2 5
4 13 1484.88 20 15.03 2384 717 2.62 / 241.08 2 3
5 13 812.20 20 15.16 1482 449 3.07 / 241.53 2 4
6 13 74.16 20 15.36 434 133 3.20 / 241.67 2 3
7 8 0.20 175 15.34 318 854 4.05 / 242.52 2 7
8 14 0.20 20 15.32 321 98 4.15 / 242.62 2 12
Average= 4.04
(KJ/cycle)

Cycle 58 GMT 31/ 7/2020 4:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.40 33 15.29 466 235 0.24 / 234.68 2 2
2 12 1187.36 4 15.41 2038 126 0.36 / 234.81 2 3
3 7 1996.72 34 14.97 3006 1530 1.89 / 236.34 2 4
4 13 1336.48 20 15.05 2191 659 2.55 / 237.00 2 3
5 13 862.20 20 15.14 1552 470 3.02 / 237.47 2 5
6 13 82.76 20 15.36 452 139 3.16 / 237.61 2 3
7 8 -0.08 175 15.34 321 862 4.02 / 238.47 2 8
Average= 4.04
(KJ/cycle)

Cycle 57 GMT 21/ 7/2020 3:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.80 33 15.30 468 236 0.24 / 230.62 2 2
2 12 1183.40 4 15.42 2037 126 0.36 / 230.74 2 2
3 7 1996.64 31 15.00 3015 1402 1.76 / 232.14 2 3
4 13 1504.32 19 15.03 2413 689 2.45 / 232.83 2 3
5 13 1018.24 19 15.10 1776 510 2.96 / 233.34 2 4
6 13 323.00 19 15.30 784 228 3.19 / 233.57 2 3
7 8 0.00 175 15.34 326 875 4.07 / 234.45 2 11
Average= 4.04
(KJ/cycle)

Cycle 56 GMT 11/ 7/2020 3:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.96 33 15.31 488 247 0.25 / 226.65 2 2
2 12 1185.84 4 15.42 2047 126 0.37 / 226.77 2 3
3 7 2002.76 31 15.00 3012 1401 1.77 / 228.17 2 3
4 13 1497.44 19 15.03 2389 682 2.46 / 228.85 2 4
5 13 996.32 19 15.12 1726 496 2.95 / 229.35 2 5
6 13 168.88 19 15.35 567 165 3.12 / 229.52 2 3
7 8 0.36 175 15.35 322 865 3.98 / 230.38 2 8
Average= 4.04
(KJ/cycle)

Cycle 55 GMT 1/ 7/2020 3:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.00 33 15.31 479 242 0.24 / 222.62 2 2
2 12 1182.24 4 15.42 2043 126 0.37 / 222.74 2 3
3 7 2000.68 31 15.00 3033 1410 1.78 / 224.15 2 4
4 13 1511.24 19 15.03 2420 691 2.47 / 224.85 2 4
5 13 1003.68 19 15.11 1748 502 2.97 / 225.35 2 5
6 13 164.24 19 15.35 568 166 3.14 / 225.51 2 3
7 8 -0.16 175 15.35 330 886 4.02 / 226.40 2 7
Average= 4.04
(KJ/cycle)

Cycle 54 GMT 21/ 6/2020 4:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.04 33 15.31 490 248 0.25 / 218.54 2 2
2 12 1175.60 3 15.44 2022 94 0.34 / 218.64 2 3
3 7 2003.96 31 15.03 3023 1409 1.75 / 220.04 2 4
4 13 1521.20 19 15.04 2427 694 2.44 / 220.74 2 5
5 13 1033.88 19 15.11 1780 511 2.95 / 221.25 2 4
6 13 352.52 19 15.31 832 242 3.20 / 221.49 2 3
7 8 0.16 175 15.36 329 884 4.08 / 222.38 2 7
Average= 4.04
(KJ/cycle)

Cycle 53 GMT 11/ 6/2020 6:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.96 33 15.32 462 234 0.23 / 214.49 2 2
2 12 1186.04 3 15.45 2058 95 0.33 / 214.58 2 3
3 7 2003.32 31 15.02 3017 1405 1.73 / 215.99 2 4
4 13 1509.20 19 15.04 2411 689 2.42 / 216.68 2 3
5 13 1009.00 19 15.12 1750 503 2.93 / 217.18 2 5
6 13 313.88 19 15.32 780 227 3.15 / 217.41 2 3
7 8 0.20 175 15.36 330 887 4.04 / 218.30 2 8
Average= 4.04
(KJ/cycle)

Cycle 52 GMT 1/ 6/2020 8:19:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.40 33 15.33 488 247 0.25 / 210.46 2 2
2 12 1191.56 3 15.43 2037 94 0.34 / 210.56 2 3
3 7 2004.48 31 15.03 3010 1402 1.74 / 211.96 2 3
4 13 1408.80 19 15.06 2288 655 2.40 / 212.61 2 3
5 13 955.52 19 15.14 1676 482 2.88 / 213.10 2 5
6 13 452.60 19 15.28 969 281 3.16 / 213.38 2 3
7 8 0.04 175 15.36 327 879 4.04 / 214.26 2 11
Average= 4.04
(KJ/cycle)

Cycle 51 GMT 22/ 5/2020 9:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.56 33 15.33 476 241 0.24 / 206.19 2 2
2 12 1179.28 3 15.45 2022 94 0.33 / 206.29 2 3
3 7 2009.16 34 15.00 3026 1543 1.88 / 207.83 2 4
4 13 1496.32 19 15.04 2402 686 2.56 / 208.52 2 3
5 13 974.24 19 15.13 1712 492 3.06 / 209.01 2 4
6 13 271.52 19 15.34 721 210 3.27 / 209.22 2 3
7 8 0.28 175 15.37 332 893 4.16 / 210.11 2 9
8 14 0.28 20 15.34 332 102 4.26 / 210.21 2 11
Average= 4.04
(KJ/cycle)

Cycle 50 GMT 12/ 5/2020 11:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.52 33 15.34 467 236 0.24 / 202.15 2 2
2 12 1185.72 3 15.43 2055 95 0.33 / 202.25 2 3
3 7 2002.64 34 15.00 3019 1540 1.87 / 203.79 2 5
4 13 1359.56 19 15.08 2223 637 2.51 / 204.43 2 3
5 13 899.64 19 15.16 1598 460 2.97 / 204.89 2 4
6 13 221.12 19 15.36 654 191 3.16 / 205.08 2 3
7 8 0.04 175 15.37 326 877 4.04 / 205.95 2 5
Average= 4.04
(KJ/cycle)

Cycle 49 GMT 2/ 5/2020 12:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.84 33 15.34 473 239 0.24 / 198.08 2 2
2 12 1181.84 3 15.44 2045 95 0.33 / 198.18 2 2
3 7 2001.92 34 15.01 3023 1543 1.88 / 199.72 2 3
4 13 1474.72 19 15.06 2370 678 2.56 / 200.40 2 4
5 13 951.92 19 15.16 1679 484 3.04 / 200.88 2 4
6 13 129.96 19 15.39 524 153 3.19 / 201.03 2 3
7 8 0.12 175 15.38 328 883 4.07 / 201.92 2 8
Average= 4.04
(KJ/cycle)

Cycle 48 GMT 22/ 4/2020 14:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.28 33 15.33 484 245 0.24 / 193.98 2 2
2 12 1176.28 3 15.45 2050 95 0.34 / 194.08 2 2
3 7 2002.12 34 15.01 3016 1539 1.88 / 195.62 2 4
4 13 1495.00 19 15.06 2394 685 2.56 / 196.30 2 3
5 13 990.88 19 15.14 1741 501 3.06 / 196.80 2 4
6 13 155.28 19 15.38 564 165 3.23 / 196.97 2 3
7 8 0.00 175 15.38 325 875 4.10 / 197.84 2 8
Average= 4.04
(KJ/cycle)

Cycle 47 GMT 12/ 4/2020 16:41: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.72 33 15.35 468 237 0.24 / 189.91 2 2
2 12 1175.68 3 15.45 2048 95 0.33 / 190.00 2 3
3 7 2006.64 34 15.01 3016 1539 1.87 / 191.54 2 3
4 13 1393.00 19 15.07 2271 650 2.52 / 192.19 2 3
5 13 908.00 19 15.16 1629 469 2.99 / 192.66 2 4
6 13 215.76 19 15.37 641 187 3.18 / 192.85 2 3
7 8 0.32 175 15.38 330 888 4.07 / 193.74 2 6
Average= 4.04
(KJ/cycle)

Cycle 46 GMT 2/ 4/2020 18:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.64 33 15.35 484 245 0.25 / 185.73 2 2
2 12 1175.16 3 15.45 2026 94 0.34 / 185.82 2 2
3 7 2002.08 34 15.02 3009 1537 1.88 / 187.36 2 3
4 13 1666.12 19 15.02 2616 747 2.62 / 188.11 2 4
5 13 947.40 19 15.16 1671 481 3.10 / 188.59 2 5
6 13 250.28 19 15.37 687 201 3.30 / 188.79 2 3
7 8 -0.12 175 15.39 328 883 4.19 / 189.67 2 8
Average= 4.04
(KJ/cycle)

Cycle 45 GMT 23/ 3/2020 20: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.68 33 15.34 482 244 0.24 / 181.65 2 2
2 12 1178.08 3 15.46 2035 94 0.34 / 181.74 2 3
3 7 2001.40 34 15.02 3026 1545 1.88 / 183.29 2 4
4 13 1490.20 19 15.06 2395 685 2.57 / 183.97 2 4
5 13 967.04 19 15.16 1704 491 3.06 / 184.46 2 4
6 13 85.60 19 15.42 461 135 3.19 / 184.60 2 3
7 8 0.04 175 15.40 329 887 4.08 / 185.48 2 6
Average= 4.03
(KJ/cycle)

Cycle 44 GMT 13/ 3/2020 21:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.40 33 15.35 479 243 0.24 / 177.51 2 2
2 12 1180.80 3 15.46 2061 96 0.34 / 177.61 2 3
3 7 2004.56 34 15.02 3022 1543 1.88 / 179.15 2 3
4 13 1492.12 19 15.07 2392 685 2.57 / 179.84 2 3
5 13 847.32 19 15.21 1534 443 3.01 / 180.28 2 4
6 13 319.48 19 15.35 788 230 3.24 / 180.51 2 3
7 8 0.08 175 15.39 331 891 4.13 / 181.40 2 8
Average= 4.03
(KJ/cycle)

Cycle 43 GMT 3/ 3/2020 23:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.64 32 15.35 476 234 0.23 / 173.30 2 2
2 12 1190.16 3 15.45 2069 96 0.33 / 173.40 2 3
3 7 2004.92 34 15.02 3018 1541 1.87 / 174.94 2 2
4 13 1485.64 19 15.07 2383 682 2.55 / 175.62 2 3
5 13 974.56 19 15.16 1715 494 3.05 / 176.12 2 4
6 13 141.28 19 15.41 536 157 3.20 / 176.27 2 3
7 13 29.88 19 15.42 384 113 3.32 / 176.39 2 3
8 8 -0.24 175 15.39 329 886 4.20 / 177.27 2 7
Average= 4.03
(KJ/cycle)

Cycle 42 GMT 23/ 2/2020 1:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.68 32 15.37 480 236 0.24 / 169.27 2 2
2 12 1189.20 3 15.45 2063 96 0.33 / 169.37 2 4
3 7 2002.00 34 15.03 3012 1539 1.87 / 170.91 2 5
4 13 1357.44 19 15.10 2219 637 2.51 / 171.54 2 3
5 13 885.24 19 15.20 1584 457 2.96 / 172.00 2 5
6 13 192.80 19 15.40 613 179 3.14 / 172.18 2 3
7 8 0.04 175 15.40 330 889 4.03 / 173.07 2 11
Average= 4.02
(KJ/cycle)

Cycle 41 GMT 13/ 2/2020 3: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.60 32 15.37 477 235 0.23 / 165.17 2 2
2 12 1189.64 3 15.46 2062 96 0.33 / 165.27 2 3
3 7 2003.84 34 15.03 3029 1548 1.88 / 166.82 2 3
4 13 1481.12 19 15.08 2394 686 2.56 / 167.50 2 3
5 13 969.08 19 15.18 1699 490 3.05 / 167.99 2 5
6 13 138.88 19 15.42 538 158 3.21 / 168.15 2 3
7 8 0.04 175 15.41 328 885 4.10 / 169.04 2 7
Average= 4.02
(KJ/cycle)

Cycle 40 GMT 3/ 2/2020 4:40: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.08 32 15.38 462 227 0.23 / 160.98 2 2
2 12 1176.76 2 15.48 2042 63 0.29 / 161.05 2 3
3 7 2007.72 34 15.03 3014 1540 1.83 / 162.59 2 3
4 13 1675.68 19 15.05 2623 750 2.58 / 163.34 2 4
5 13 976.04 19 15.18 1711 493 3.07 / 163.83 2 4
6 13 288.32 19 15.38 745 218 3.29 / 164.05 2 3
7 8 0.28 175 15.41 330 890 4.18 / 164.94 2 7
Average= 4.02
(KJ/cycle)

Cycle 39 GMT 24/ 1/2020 6:40: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.80 32 15.37 479 236 0.24 / 156.91 2 2
2 12 1189.12 2 15.47 2061 64 0.30 / 156.97 2 3
3 7 2006.00 34 15.04 3018 1543 1.84 / 158.52 2 3
4 13 1490.92 19 15.09 2388 685 2.53 / 159.20 2 3
5 13 986.56 19 15.18 1721 496 3.02 / 159.70 2 4
6 13 162.44 19 15.42 572 168 3.19 / 159.87 2 3
7 8 0.04 175 15.42 330 891 4.08 / 160.76 2 11
Average= 4.02
(KJ/cycle)

Cycle 38 GMT 14/ 1/2020 8:34: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.96 32 15.37 482 237 0.24 / 152.86 2 2
2 12 1178.88 2 15.48 2053 64 0.30 / 152.93 2 3
3 7 2002.08 34 15.04 3019 1544 1.84 / 154.47 2 4
4 13 1372.72 19 15.11 2243 644 2.49 / 155.11 2 3
5 13 901.12 19 15.20 1617 467 2.96 / 155.58 2 4
6 13 220.68 19 15.40 653 191 3.15 / 155.77 2 3
7 8 0.12 175 15.41 335 903 4.05 / 156.68 2 8
Average= 4.02
(KJ/cycle)

Cycle 37 GMT 4/ 1/2020 10:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.92 32 15.37 474 233 0.23 / 148.71 2 2
2 12 1176.44 2 15.48 2048 63 0.30 / 148.77 2 3
3 7 2006.72 34 15.04 3029 1549 1.85 / 150.32 2 6
4 13 1496.00 19 15.09 2394 686 2.53 / 151.01 2 3
5 13 984.36 19 15.18 1731 499 3.03 / 151.51 2 5
6 13 276.76 19 15.39 735 215 3.25 / 151.72 2 3
7 8 0.24 175 15.41 335 903 4.15 / 152.63 2 7
Average= 4.02
(KJ/cycle)

Cycle 36 GMT 25/12/2019 12:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.40 32 15.37 487 240 0.24 / 144.53 2 2
2 12 1172.00 2 15.49 2038 63 0.30 / 144.60 2 3
3 7 2003.08 34 15.05 3022 1546 1.85 / 146.14 2 4
4 13 1506.72 19 15.09 2410 691 2.54 / 146.83 2 3
5 13 1005.52 19 15.18 1745 503 3.04 / 147.34 2 4
6 13 304.60 19 15.38 771 225 3.27 / 147.56 2 3
7 8 0.08 175 15.41 339 914 4.18 / 148.48 2 7
Average= 4.01
(KJ/cycle)

Cycle 35 GMT 15/12/2019 14:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.80 32 15.38 482 237 0.24 / 140.26 2 2
2 12 1182.56 2 15.50 2043 63 0.30 / 140.33 2 3
3 7 2006.36 34 15.06 3008 1540 1.84 / 141.87 2 5
4 13 1514.48 19 15.10 2424 695 2.54 / 142.56 2 4
5 13 1150.24 19 15.15 1943 559 3.10 / 143.12 2 4
6 13 396.60 19 15.36 891 260 3.36 / 143.38 2 3
7 8 0.40 175 15.42 338 912 4.27 / 144.29 2 9
Average= 4.01
(KJ/cycle)

Cycle 34 GMT 5/12/2019 16:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.76 32 15.38 483 238 0.24 / 136.23 2 2
2 12 1185.48 2 15.50 2033 63 0.30 / 136.29 2 4
3 7 2002.76 34 15.06 3016 1544 1.85 / 137.84 2 3
4 13 1492.72 19 15.11 2401 689 2.53 / 138.53 2 4
5 13 853.48 19 15.24 1539 446 2.98 / 138.97 2 4
6 13 180.80 19 15.43 585 172 3.15 / 139.14 2 3
7 8 -0.20 175 15.43 327 883 4.03 / 140.03 2 5
Average= 4.00
(KJ/cycle)

Cycle 33 GMT 25/11/2019 18:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.68 32 15.38 480 236 0.24 / 132.10 2 2
2 12 1189.16 2 15.51 2028 63 0.30 / 132.16 2 3
3 7 2002.64 34 15.06 3009 1541 1.84 / 133.70 2 6
4 13 1507.16 19 15.11 2412 692 2.53 / 134.39 2 4
5 13 979.28 19 15.21 1719 497 3.03 / 134.89 2 4
6 13 265.76 19 15.41 712 208 3.24 / 135.10 2 3
7 8 0.16 175 15.43 331 894 4.13 / 135.99 2 9
Average= 4.00
(KJ/cycle)

Cycle 32 GMT 15/11/2019 21: 6: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.88 32 15.39 490 241 0.24 / 127.84 2 2
2 12 1177.88 2 15.52 2035 63 0.30 / 127.91 2 3
3 7 2005.60 34 15.06 3019 1546 1.85 / 129.45 2 4
4 13 1509.08 19 15.10 2419 694 2.54 / 130.15 2 4
5 13 998.52 19 15.20 1746 504 3.05 / 130.65 2 4
6 13 282.80 19 15.40 730 214 3.26 / 130.86 2 3
7 8 0.12 175 15.43 331 894 4.16 / 131.76 2 5
8 14 0.12 20 15.41 332 102 4.26 / 131.86 2 9
Average= 4.00
(KJ/cycle)

Cycle 31 GMT 5/11/2019 23: 2: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.56 32 15.40 482 238 0.24 / 123.76 2 2
2 12 1178.52 2 15.52 2021 63 0.30 / 123.83 2 3
3 7 2002.20 34 15.08 3007 1542 1.84 / 125.37 2 3
4 13 1486.60 19 15.12 2388 686 2.53 / 126.06 2 4
5 13 975.76 19 15.22 1707 494 3.02 / 126.55 2 6
6 13 147.04 19 15.45 541 159 3.18 / 126.71 2 3
7 8 -0.12 175 15.44 331 894 4.07 / 127.60 2 8
Average= 3.99
(KJ/cycle)

Cycle 30 GMT 27/10/2019 1:10:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.24 32 15.39 507 250 0.25 / 119.71 2 2
2 12 1186.36 2 15.52 2044 63 0.31 / 119.77 2 2
3 7 2005.60 34 15.06 3025 1549 1.86 / 121.32 2 3
4 13 1508.56 19 15.11 2415 693 2.56 / 122.02 2 3
5 13 859.92 19 15.26 1548 449 3.00 / 122.46 2 3
6 13 182.76 19 15.44 584 171 3.18 / 122.64 2 3
7 8 0.16 175 15.44 330 892 4.07 / 123.53 2 6
Average= 3.98
(KJ/cycle)

Cycle 29 GMT 17/10/2019 2:55: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.20 32 15.40 487 240 0.24 / 115.45 2 2
2 12 1177.52 2 15.53 2027 63 0.30 / 115.51 2 2
3 7 2002.00 34 15.08 3012 1544 1.85 / 117.05 2 2
4 13 1510.40 19 15.12 2434 699 2.55 / 117.75 2 3
5 13 863.04 19 15.26 1553 450 3.00 / 118.20 2 3
6 13 343.36 19 15.40 830 243 3.24 / 118.45 2 3
7 8 0.04 175 15.44 337 911 4.15 / 119.36 2 6
8 14 0.04 20 15.42 337 104 4.25 / 119.46 2 6
Average= 3.98
(KJ/cycle)

Cycle 28 GMT 7/10/2019 4:48:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.32 32 15.41 476 235 0.23 / 111.27 2 2
2 12 1168.04 2 15.52 2031 63 0.30 / 111.34 2 2
3 7 2004.12 34 15.08 3013 1545 1.84 / 112.88 2 3
4 13 1492.48 19 15.13 2409 693 2.54 / 113.57 2 3
5 13 984.32 19 15.22 1723 498 3.03 / 114.07 2 3
6 13 275.68 19 15.42 728 213 3.25 / 114.29 2 3
7 8 0.20 175 15.45 340 919 4.17 / 115.21 2 10
Average= 3.97
(KJ/cycle)

Cycle 27 GMT 27/ 9/2019 6:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.04 32 15.41 478 236 0.24 / 107.01 2 2
2 12 1177.44 2 15.53 2013 63 0.30 / 107.08 2 2
3 7 2008.80 34 15.08 3016 1546 1.84 / 108.62 2 2
4 13 1511.48 19 15.12 2427 697 2.54 / 109.32 2 3
5 13 988.88 19 15.22 1734 501 3.04 / 109.82 2 3
6 13 288.40 19 15.42 737 216 3.26 / 110.04 2 3
7 8 0.08 175 15.45 333 900 4.16 / 110.94 2 9
8 14 0.08 20 15.43 333 103 4.26 / 111.04 2 9
Average= 3.97
(KJ/cycle)

Cycle 26 GMT 17/ 9/2019 8:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.44 32 15.41 489 241 0.24 / 102.86 2 2
2 12 1184.12 2 15.51 2034 63 0.30 / 102.93 2 2
3 7 2003.40 34 15.08 3018 1547 1.85 / 104.47 2 3
4 13 1497.44 19 15.13 2408 692 2.54 / 105.17 2 3
5 13 974.56 19 15.23 1713 496 3.04 / 105.66 2 3
6 13 262.76 19 15.43 708 208 3.25 / 105.87 2 3
7 8 0.12 175 15.45 336 908 4.16 / 106.78 2 8
Average= 3.95
(KJ/cycle)

Cycle 25 GMT 7/ 9/2019 10:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.80 32 15.41 501 247 0.25 / 98.74 2 2
2 12 1177.00 2 15.53 2042 63 0.31 / 98.80 2 2
3 7 2003.88 34 15.09 3011 1545 1.86 / 100.35 2 2
4 13 1506.88 19 15.13 2430 699 2.55 / 101.04 2 3
5 13 986.60 19 15.23 1730 501 3.05 / 101.54 2 3
6 13 143.64 19 15.47 546 160 3.21 / 101.70 2 3
7 8 0.04 175 15.46 339 917 4.13 / 102.62 2 8
Average= 3.95
(KJ/cycle)

Cycle 24 GMT 28/ 8/2019 12:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.96 32 15.41 501 247 0.25 / 94.49 2 2
2 12 1178.68 2 15.53 2042 63 0.31 / 94.55 2 2
3 7 2002.24 34 15.08 3027 1552 1.86 / 96.11 2 2
4 13 1501.08 19 15.14 2417 695 2.56 / 96.80 2 3
5 13 987.32 19 15.23 1734 502 3.06 / 97.30 2 3
6 13 147.04 19 15.47 557 164 3.22 / 97.47 2 3
7 8 0.16 175 15.46 339 917 4.14 / 98.38 2 10
8 14 0.16 20 15.44 345 107 4.25 / 98.49 2 8
Average= 3.94
(KJ/cycle)

Cycle 23 GMT 18/ 8/2019 14:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 122.08 32 15.42 517 255 0.26 / 90.31 2 2
2 12 1188.72 2 15.52 2043 63 0.32 / 90.37 2 2
3 7 2003.52 34 15.09 3025 1552 1.87 / 91.92 2 2
4 13 1489.40 19 15.14 2412 694 2.56 / 92.62 2 3
5 13 982.28 19 15.24 1724 499 3.06 / 93.12 2 3
6 13 264.60 19 15.44 719 211 3.27 / 93.33 2 3
7 8 -0.04 175 15.46 338 914 4.19 / 94.24 2 4
Average= 3.93
(KJ/cycle)

Cycle 22 GMT 8/ 8/2019 16:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.28 32 15.42 487 240 0.24 / 86.17 2 2
2 12 1178.20 2 15.54 2023 63 0.30 / 86.23 2 2
3 7 2002.36 34 15.10 3013 1547 1.85 / 87.77 2 2
4 13 1502.60 19 15.15 2422 697 2.55 / 88.47 2 3
5 13 980.44 19 15.24 1729 501 3.05 / 88.97 2 3
6 13 143.20 19 15.48 546 161 3.21 / 89.13 2 3
7 8 0.16 175 15.47 340 920 4.13 / 90.05 2 8
Average= 3.92
(KJ/cycle)

Cycle 21 GMT 29/ 7/2019 18:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.64 32 15.44 478 236 0.24 / 82.01 2 2
2 12 1189.16 2 15.54 2053 64 0.30 / 82.07 2 2
3 7 2004.72 34 15.10 3034 1558 1.86 / 83.63 2 3
4 13 1492.60 19 15.15 2409 693 2.55 / 84.33 2 3
5 13 973.00 19 15.25 1717 498 3.05 / 84.82 2 3
6 13 258.48 19 15.45 701 206 3.25 / 85.03 2 3
7 8 0.00 175 15.47 331 896 4.15 / 85.92 2 5
Average= 3.91
(KJ/cycle)

Cycle 20 GMT 19/ 7/2019 20:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.36 32 15.43 479 237 0.24 / 77.92 2 2
2 12 1182.76 2 15.54 2051 64 0.30 / 77.98 2 2
3 7 2006.28 34 15.10 3031 1556 1.86 / 79.54 2 3
4 13 1497.08 19 15.16 2413 695 2.55 / 80.23 2 3
5 13 974.28 19 15.25 1713 496 3.05 / 80.73 2 3
6 13 142.12 19 15.48 538 158 3.21 / 80.89 2 3
7 8 0.40 175 15.48 328 889 4.09 / 81.77 2 6
Average= 3.89
(KJ/cycle)

Cycle 19 GMT 9/ 7/2019 22:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.76 32 15.43 482 238 0.24 / 73.78 2 2
2 12 1182.44 2 15.54 2056 64 0.30 / 73.85 2 2
3 7 2002.48 34 15.10 3015 1548 1.85 / 75.40 2 3
4 13 1496.92 19 15.16 2401 692 2.54 / 76.09 2 3
5 13 967.76 19 15.26 1706 495 3.04 / 76.58 2 3
6 13 231.96 19 15.46 666 196 3.23 / 76.78 2 3
7 8 -0.12 175 15.48 333 902 4.13 / 77.68 2 7
Average= 3.88
(KJ/cycle)

Cycle 18 GMT 30/ 6/2019 1: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.80 31 15.43 497 238 0.24 / 69.66 2 2
2 7 2006.56 34 15.11 3015 1549 1.79 / 71.20 2 2
3 13 1519.32 19 15.16 2442 703 2.49 / 71.91 2 2
4 13 1001.24 19 15.25 1753 508 3.00 / 72.42 2 3
5 13 316.08 19 15.44 787 231 3.23 / 72.65 2 3
6 8 0.08 175 15.48 332 899 4.13 / 73.55 2 4
Average= 3.87
(KJ/cycle)

Cycle 17 GMT 20/ 6/2019 3:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.76 31 15.44 490 235 0.23 / 65.46 2 2
2 7 2004.36 34 15.11 3016 1549 1.78 / 67.01 2 2
3 13 1502.56 19 15.17 2418 697 2.48 / 67.70 2 2
4 13 1002.64 19 15.25 1762 511 2.99 / 68.21 2 2
5 13 171.20 19 15.48 581 171 3.16 / 68.39 2 2
6 13 36.56 19 15.51 396 117 3.28 / 68.50 2 2
7 8 0.16 175 15.48 338 916 4.19 / 69.42 2 4
Average= 3.86
(KJ/cycle)

Cycle 16 GMT 10/ 6/2019 5:37:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.12 31 15.44 497 238 0.24 / 61.32 2 2
2 7 2010.04 34 15.11 3036 1560 1.80 / 62.88 2 2
3 13 1512.72 19 15.16 2431 700 2.50 / 63.58 2 2
4 13 1003.12 19 15.25 1766 512 3.01 / 64.09 2 3
5 13 285.88 19 15.45 744 218 3.23 / 64.31 2 2
6 8 -0.04 175 15.48 338 916 4.14 / 65.22 2 13
Average= 3.84
(KJ/cycle)

Cycle 15 GMT 31/ 5/2019 7:52: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.20 31 15.44 492 235 0.24 / 57.07 2 2
2 7 2003.92 34 15.12 3031 1558 1.79 / 58.62 2 2
3 13 1518.48 19 15.17 2439 703 2.50 / 59.33 2 2
4 13 1003.60 19 15.25 1765 511 3.01 / 59.84 2 3
5 13 309.96 19 15.45 781 229 3.24 / 60.07 2 2
6 8 0.20 175 15.49 335 908 4.15 / 60.98 2 7
7 14 0.20 20 15.46 337 104 4.25 / 61.08 2 7
Average= 3.82
(KJ/cycle)

Cycle 14 GMT 21/ 5/2019 9:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.24 31 15.45 489 234 0.23 / 52.97 2 2
2 7 2008.12 34 15.12 3015 1550 1.78 / 54.52 2 2
3 13 1518.24 19 15.17 2446 705 2.49 / 55.23 2 2
4 13 998.92 19 15.26 1757 509 3.00 / 55.74 2 3
5 13 157.24 19 15.50 574 169 3.17 / 55.91 2 2
6 8 0.04 175 15.49 341 924 4.09 / 56.83 2 4
Average= 3.79
(KJ/cycle)

Cycle 13 GMT 11/ 5/2019 12: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.08 31 15.45 484 232 0.23 / 48.90 2 2
2 7 2004.24 34 15.13 3017 1552 1.78 / 50.45 2 2
3 13 1511.40 19 15.18 2431 701 2.48 / 51.15 2 2
4 13 999.32 19 15.26 1750 507 2.99 / 51.66 2 3
5 13 173.08 19 15.50 595 175 3.17 / 51.83 2 2
6 8 0.16 175 15.50 334 906 4.07 / 52.74 2 5
Average= 3.77
(KJ/cycle)

Cycle 12 GMT 1/ 5/2019 14: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.36 31 15.45 483 231 0.23 / 44.78 2 2
2 7 2002.28 34 15.13 3008 1547 1.78 / 46.32 2 2
3 13 1509.24 19 15.19 2409 695 2.47 / 47.02 2 2
4 13 1002.00 19 15.27 1749 507 2.98 / 47.53 2 3
5 13 313.00 19 15.46 776 228 3.21 / 47.75 2 2
6 8 0.16 175 15.49 336 911 4.12 / 48.66 2 5
Average= 3.74
(KJ/cycle)

Cycle 11 GMT 21/ 4/2019 16:20: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.84 31 15.45 484 232 0.23 / 40.53 2 2
2 7 2002.48 34 15.14 3028 1559 1.79 / 42.09 2 2
3 13 1508.80 19 15.18 2427 700 2.49 / 42.79 2 2
4 13 998.64 19 15.27 1755 509 3.00 / 43.30 2 3
5 13 283.96 19 15.46 744 219 3.22 / 43.51 2 2
6 13 19.88 19 15.53 377 111 3.33 / 43.63 2 2
7 8 0.08 175 15.49 339 919 4.25 / 44.54 2 8
Average= 3.71
(KJ/cycle)

Cycle 10 GMT 11/ 4/2019 18:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.24 31 15.46 488 234 0.23 / 36.40 2 2
2 7 2006.72 34 15.14 3031 1560 1.79 / 37.96 2 2
3 13 1505.48 19 15.18 2419 698 2.49 / 38.66 2 2
4 13 995.96 19 15.27 1744 506 3.00 / 39.16 2 3
5 13 279.24 19 15.47 741 218 3.22 / 39.38 2 3
6 8 0.04 175 15.50 337 914 4.13 / 40.30 2 6
Average= 3.66
(KJ/cycle)

Cycle 9 GMT 1/ 4/2019 20:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.28 31 15.46 472 226 0.23 / 32.28 2 2
2 7 2009.96 34 15.14 3007 1548 1.77 / 33.83 2 2
3 13 1520.00 19 15.19 2428 701 2.47 / 34.53 2 2
4 13 1008.52 19 15.27 1762 511 2.99 / 35.04 2 3
5 13 299.48 19 15.47 767 225 3.21 / 35.26 2 3
6 8 0.04 175 15.50 333 903 4.11 / 36.17 2 6
Average= 3.62
(KJ/cycle)

Cycle 8 GMT 22/ 3/2019 22:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.04 31 15.46 483 231 0.23 / 28.12 2 2
2 3 1022.80 1 15.51 1843 29 0.26 / 28.14 2 2
3 7 2002.08 34 15.14 3009 1549 1.81 / 29.69 2 2
4 13 1494.40 18 15.20 2408 659 2.47 / 30.35 2 2
5 13 1007.28 18 15.28 1766 486 2.95 / 30.84 2 3
6 13 309.32 18 15.47 773 215 3.17 / 31.05 2 2
7 13 26.88 18 15.54 377 105 3.27 / 31.16 2 2
8 8 0.08 175 15.50 329 892 4.17 / 32.05 2 5
Average= 3.56
(KJ/cycle)

Cycle 7 GMT 13/ 3/2019 0:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.32 30 15.47 468 217 0.22 / 23.98 2 2
2 7 2009.20 34 15.15 3015 1553 1.77 / 25.53 2 2
3 13 1498.96 18 15.21 2410 660 2.43 / 26.19 2 2
4 13 984.24 18 15.29 1733 477 2.91 / 26.66 2 2
5 13 291.32 18 15.48 746 208 3.11 / 26.87 2 2
6 13 46.48 18 15.53 409 114 3.23 / 26.99 2 2
7 8 -0.04 175 15.50 331 898 4.13 / 27.88 2 7
Average= 3.49
(KJ/cycle)

Cycle 6 GMT 3/ 3/2019 3:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.16 30 15.47 475 220 0.22 / 19.75 2 2
2 10 1003.24 2 15.45 1781 55 0.28 / 19.80 2 2
3 3 971.28 -1 15.80 0 0 0.06 / 19.80 2 2
4 3 1027.60 1 15.52 1868 29 0.30 / 19.83 2 2
5 7 2002.48 38 15.13 3006 1728 2.03 / 21.56 2 2
6 13 1466.72 18 15.21 2373 650 2.68 / 22.21 2 2
7 13 797.76 18 15.35 1464 405 3.09 / 22.61 2 3
8 13 139.16 18 15.52 532 149 3.24 / 22.76 2 3
9 13 24.72 18 15.54 372 104 3.34 / 22.86 2 3
10 8 0.00 175 15.51 329 893 4.23 / 23.76 2 7
Average= 3.39
(KJ/cycle)

Cycle 5 GMT 21/ 2/2019 5:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.28 31 15.49 477 229 0.23 / 15.73 2 2
2 3 943.56 -1 15.81 0 0 0.00 / 15.73 2 2
3 7 2008.60 38 15.13 3008 1729 1.96 / 17.46 2 2
4 13 1346.16 18 15.24 2205 605 2.56 / 18.07 2 3
5 13 836.16 18 15.34 1525 421 2.98 / 18.49 2 3
6 13 140.32 18 15.52 540 151 3.14 / 18.64 2 3
7 8 0.28 175 15.51 327 888 4.02 / 19.53 2 8
Average= 3.25
(KJ/cycle)

Cycle 4 GMT 11/ 2/2019 7:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.32 29 15.50 446 200 0.20 / 12.18 2 2
2 7 1507.28 38 15.29 2358 1370 1.57 / 13.55 2 2
3 13 1214.48 18 15.31 2010 554 2.12 / 14.10 2 2
4 13 707.84 18 15.40 1333 370 2.49 / 14.47 2 3
5 13 69.04 18 15.55 441 123 2.62 / 14.60 2 3
6 8 0.12 175 15.53 333 905 3.52 / 15.50 2 7
Average= 3.10
(KJ/cycle)

Cycle 3 GMT 10/ 2/2019 7:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.40 29 15.50 444 200 0.20 / 8.80 2 2
2 7 1509.36 38 15.29 2365 1374 1.57 / 10.17 2 2
3 13 1216.32 18 15.31 2003 552 2.13 / 10.72 2 2
4 13 709.52 18 15.40 1317 365 2.49 / 11.09 2 3
5 13 43.36 18 15.56 378 106 2.60 / 11.19 2 3
6 8 0.12 165 15.54 307 787 3.38 / 11.98 2 9
Average= 2.99
(KJ/cycle)

Cycle 2 GMT 9/ 2/2019 7:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.08 29 15.51 453 204 0.20 / 5.05 2 2
2 7 1521.52 74 15.20 2358 2652 2.86 / 7.70 2 2
3 13 65.28 18 15.56 408 114 2.97 / 7.82 2 3
4 8 0.08 165 15.54 304 779 3.75 / 8.60 2 7
Average= 2.87
(KJ/cycle)

Cycle 1 GMT 8/ 2/2019 7:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.08 29 15.70 398 181 0.18 / 1.77 2 2
2 7 1003.88 75 15.37 1674 1930 2.11 / 3.70 2 3
3 8 -0.12 240 15.56 308 1150 3.26 / 4.85 2 15
Average= 2.42
(KJ/cycle)

Cycle 0 GMT 7/ 2/2019 21:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.60 28 15.84 406 180 0.18 / 0.18 2 2
2 7 125.88 74 15.81 415 486 0.67 / 0.67 2 2
3 8 -0.04 240 15.77 243 920 1.59 / 1.59 2 9
Average= 1.59