SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.56 | 39 | 10.97 | 429 | 184 | 0.18 / 1362.56 | 2 | 2 |
2 | 3 | 1039.80 | 2 | 8.85 | 1691 | 30 | 0.21 / 1362.59 | 2 | 2 |
3 | 12 | 1119.68 | 3 | 7.30 | 1775 | 39 | 0.25 / 1362.63 | 2 | 2 |
4 | 12 | 1153.60 | 120 | 5.91 | 1755 | 1245 | 1.50 / 1363.87 | 2 | 2 |
5 | 12 | 1165.80 | 88 | 5.43 | 1514 | 723 | 2.22 / 1364.59 | 2 | 2 |
6 | 7 | 1169.04 | 23 | 5.67 | 1814 | 237 | 2.46 / 1364.83 | 2 | 2 |
7 | 13 | 1231.28 | 36 | 6.12 | 1906 | 420 | 2.88 / 1365.25 | 2 | 2 |
8 | 13 | 1197.96 | 36 | 6.39 | 1887 | 434 | 3.31 / 1365.68 | 2 | 2 |
9 | 13 | 1105.32 | 36 | 6.72 | 1769 | 428 | 3.74 / 1366.11 | 2 | 2 |
10 | 13 | 987.56 | 36 | 7.20 | 1614 | 418 | 4.16 / 1366.53 | 2 | 2 |
11 | 13 | 570.36 | 36 | 8.67 | 1059 | 331 | 4.49 / 1366.86 | 2 | 2 |
12 | 8 | 0.08 | 180 | 10.62 | 267 | 510 | 5.00 / 1367.37 | 2 | 2 |
Average= | 5.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.24 | 31 | 11.99 | 439 | 163 | 0.16 / 1358.38 | 2 | 2 |
2 | 10 | 1035.64 | 6 | 10.69 | 1733 | 111 | 0.27 / 1358.50 | 2 | 2 |
3 | 3 | 1038.56 | 2 | 10.57 | 1742 | 37 | 0.31 / 1358.53 | 2 | 2 |
4 | 12 | 1111.48 | 3 | 8.06 | 1753 | 42 | 0.35 / 1358.58 | 2 | 2 |
5 | 12 | 1152.40 | 120 | 7.07 | 1836 | 1558 | 1.91 / 1360.13 | 2 | 2 |
6 | 12 | 1146.04 | 88 | 5.77 | 1794 | 911 | 2.82 / 1361.04 | 2 | 2 |
7 | 7 | 1135.48 | 23 | 7.26 | 1827 | 305 | 3.13 / 1361.35 | 2 | 2 |
8 | 13 | 575.48 | 36 | 9.56 | 1077 | 371 | 3.50 / 1361.72 | 2 | 2 |
9 | 13 | 11.12 | 36 | 11.25 | 284 | 115 | 3.61 / 1361.83 | 2 | 2 |
10 | 8 | -0.04 | 180 | 11.16 | 268 | 538 | 4.15 / 1362.37 | 2 | 4 |
Average= | 5.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.44 | 35 | 12.32 | 439 | 189 | 0.19 / 1351.40 | 2 | 2 |
2 | 3 | 1025.80 | 1 | 10.95 | 1714 | 19 | 0.21 / 1351.42 | 2 | 2 |
3 | 12 | 1094.00 | 3 | 10.85 | 1797 | 58 | 0.27 / 1351.47 | 2 | 2 |
4 | 12 | 2006.60 | 120 | 6.94 | 2912 | 2425 | 2.69 / 1353.90 | 2 | 2 |
5 | 12 | 1992.80 | 88 | 5.58 | 2106 | 1034 | 3.73 / 1354.93 | 2 | 2 |
6 | 7 | 1984.60 | 23 | 6.86 | 2985 | 471 | 4.20 / 1355.40 | 2 | 2 |
7 | 13 | 1863.08 | 36 | 8.09 | 2837 | 826 | 5.02 / 1356.23 | 2 | 2 |
8 | 13 | 1460.40 | 36 | 8.74 | 2313 | 728 | 5.75 / 1356.96 | 2 | 2 |
9 | 13 | 770.48 | 36 | 10.24 | 1375 | 507 | 6.26 / 1357.47 | 2 | 2 |
10 | 13 | 44.36 | 36 | 12.03 | 350 | 152 | 6.41 / 1357.62 | 2 | 2 |
11 | 8 | 0.12 | 180 | 11.95 | 281 | 604 | 7.01 / 1358.22 | 2 | 4 |
Average= | 5.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.64 | 31 | 13.28 | 446 | 184 | 0.18 / 1346.31 | 2 | 2 |
2 | 3 | 1087.00 | 4 | 11.55 | 1810 | 84 | 0.27 / 1346.40 | 2 | 2 |
3 | 12 | 1101.60 | 3 | 6.67 | 1740 | 35 | 0.30 / 1346.43 | 2 | 2 |
4 | 12 | 1159.00 | 120 | 5.84 | 1708 | 1197 | 1.50 / 1347.63 | 2 | 2 |
5 | 12 | 1177.68 | 88 | 5.43 | 1522 | 727 | 2.23 / 1348.36 | 2 | 2 |
6 | 7 | 1184.48 | 23 | 8.74 | 1887 | 379 | 2.61 / 1348.74 | 2 | 2 |
7 | 13 | 1215.48 | 36 | 8.53 | 1940 | 596 | 3.20 / 1349.33 | 2 | 2 |
8 | 13 | 1131.56 | 36 | 8.85 | 1846 | 588 | 3.79 / 1349.92 | 2 | 2 |
9 | 13 | 867.12 | 36 | 9.88 | 1493 | 531 | 4.32 / 1350.45 | 2 | 2 |
10 | 13 | 23.04 | 36 | 12.45 | 316 | 142 | 4.46 / 1350.59 | 2 | 2 |
11 | 8 | -0.20 | 180 | 12.33 | 277 | 615 | 5.08 / 1351.21 | 2 | 9 |
Average= | 5.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.68 | 32 | 13.77 | 448 | 197 | 0.20 / 1341.45 | 2 | 2 |
2 | 3 | 963.72 | -1 | 13.77 | 448 | 0 | 0.00 / 1341.45 | 2 | 2 |
3 | 3 | 1029.24 | 1 | 11.67 | 1726 | 20 | 0.22 / 1341.47 | 2 | 2 |
4 | 12 | 1101.48 | 3 | 7.49 | 1749 | 39 | 0.26 / 1341.51 | 2 | 2 |
5 | 12 | 1150.00 | 120 | 6.05 | 1717 | 1247 | 1.50 / 1342.76 | 2 | 2 |
6 | 12 | 1162.80 | 88 | 5.44 | 1543 | 739 | 2.24 / 1343.50 | 2 | 2 |
7 | 7 | 1166.84 | 23 | 9.46 | 1882 | 409 | 2.65 / 1343.91 | 2 | 2 |
8 | 13 | 1124.88 | 36 | 9.34 | 1843 | 620 | 3.27 / 1344.53 | 2 | 2 |
9 | 13 | 1010.88 | 36 | 9.86 | 1696 | 602 | 3.87 / 1345.13 | 2 | 2 |
10 | 13 | 284.32 | 36 | 12.62 | 704 | 320 | 4.19 / 1345.45 | 2 | 2 |
11 | 8 | 0.08 | 180 | 13.24 | 287 | 684 | 4.88 / 1346.13 | 2 | 7 |
Average= | 5.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.60 | 32 | 14.02 | 449 | 201 | 0.20 / 1335.80 | 2 | 2 |
2 | 12 | 1082.96 | 3 | 5.66 | 1513 | 26 | 0.23 / 1335.83 | 2 | 2 |
3 | 12 | 1149.96 | 120 | 5.55 | 1753 | 1167 | 1.39 / 1336.99 | 2 | 2 |
4 | 12 | 1172.80 | 88 | 5.44 | 1659 | 794 | 2.19 / 1337.79 | 2 | 2 |
5 | 7 | 1182.08 | 23 | 9.81 | 1901 | 429 | 2.62 / 1338.22 | 2 | 2 |
6 | 13 | 1282.80 | 36 | 9.06 | 2043 | 666 | 3.28 / 1338.88 | 2 | 2 |
7 | 13 | 1228.76 | 36 | 9.49 | 1982 | 677 | 3.96 / 1339.56 | 2 | 2 |
8 | 13 | 1106.84 | 36 | 10.02 | 1825 | 658 | 4.62 / 1340.22 | 2 | 2 |
9 | 13 | 247.84 | 36 | 13.32 | 652 | 313 | 4.93 / 1340.53 | 2 | 2 |
10 | 8 | 0.00 | 180 | 13.78 | 291 | 722 | 5.65 / 1341.25 | 2 | 9 |
Average= | 5.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.92 | 28 | 14.01 | 459 | 180 | 0.18 / 1328.73 | 2 | 2 |
2 | 10 | 1010.20 | 5 | 12.34 | 1708 | 105 | 0.29 / 1328.83 | 2 | 2 |
3 | 3 | 1054.52 | 2 | 11.72 | 1762 | 41 | 0.33 / 1328.88 | 2 | 2 |
4 | 12 | 1092.60 | 3 | 11.17 | 1809 | 61 | 0.39 / 1328.94 | 2 | 2 |
5 | 12 | 2003.52 | 120 | 7.25 | 2926 | 2546 | 2.93 / 1331.48 | 2 | 2 |
6 | 12 | 1986.48 | 88 | 5.63 | 2268 | 1124 | 4.06 / 1332.61 | 2 | 2 |
7 | 7 | 1977.40 | 23 | 9.13 | 3035 | 637 | 4.69 / 1333.24 | 2 | 2 |
8 | 13 | 1697.64 | 36 | 9.89 | 2647 | 942 | 5.64 / 1334.18 | 2 | 2 |
9 | 13 | 844.92 | 36 | 12.24 | 1504 | 663 | 6.30 / 1334.85 | 2 | 2 |
10 | 8 | 0.04 | 180 | 14.03 | 298 | 753 | 7.05 / 1335.60 | 2 | 7 |
Average= | 5.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.36 | 33 | 14.01 | 444 | 205 | 0.21 / 1323.27 | 2 | 2 |
2 | 3 | 937.08 | -1 | 14.01 | 444 | 0 | 0.00 / 1323.27 | 2 | 2 |
3 | 12 | 1090.76 | 3 | 5.55 | 1124 | 19 | 0.22 / 1323.29 | 2 | 2 |
4 | 12 | 1157.00 | 120 | 5.46 | 1424 | 933 | 1.16 / 1324.23 | 2 | 2 |
5 | 12 | 1179.12 | 88 | 5.38 | 1381 | 654 | 1.81 / 1324.88 | 2 | 2 |
6 | 7 | 1188.08 | 23 | 9.30 | 1903 | 407 | 2.22 / 1325.29 | 2 | 2 |
7 | 13 | 1282.80 | 36 | 9.16 | 2047 | 675 | 2.89 / 1325.96 | 2 | 2 |
8 | 13 | 1238.40 | 36 | 9.88 | 2007 | 714 | 3.61 / 1326.67 | 2 | 2 |
9 | 13 | 1126.52 | 36 | 10.56 | 1866 | 709 | 4.32 / 1327.38 | 2 | 2 |
10 | 13 | 372.28 | 36 | 13.26 | 842 | 402 | 4.72 / 1327.79 | 2 | 2 |
11 | 8 | 0.08 | 180 | 14.07 | 301 | 762 | 5.48 / 1328.55 | 2 | 13 |
Average= | 5.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.40 | 32 | 14.01 | 457 | 205 | 0.20 / 1317.85 | 2 | 2 |
2 | 12 | 1102.24 | 3 | 5.57 | 1100 | 18 | 0.22 / 1317.87 | 2 | 2 |
3 | 12 | 1156.64 | 120 | 5.47 | 1435 | 942 | 1.17 / 1318.82 | 2 | 2 |
4 | 12 | 1179.84 | 88 | 5.38 | 1420 | 672 | 1.84 / 1319.49 | 2 | 2 |
5 | 7 | 1189.00 | 23 | 9.24 | 1901 | 404 | 2.24 / 1319.89 | 2 | 2 |
6 | 13 | 1290.60 | 36 | 9.17 | 2035 | 672 | 2.91 / 1320.56 | 2 | 2 |
7 | 13 | 1250.88 | 36 | 9.83 | 2021 | 715 | 3.63 / 1321.28 | 2 | 2 |
8 | 13 | 1011.76 | 36 | 11.18 | 1717 | 691 | 4.32 / 1321.97 | 2 | 2 |
9 | 13 | 284.56 | 36 | 13.47 | 715 | 347 | 4.67 / 1322.32 | 2 | 2 |
10 | 8 | -0.04 | 180 | 14.11 | 296 | 752 | 5.42 / 1323.07 | 2 | 9 |
Average= | 5.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.68 | 30 | 14.12 | 446 | 189 | 0.19 / 1312.26 | 2 | 2 |
2 | 3 | 1033.44 | 1 | 11.29 | 1718 | 19 | 0.21 / 1312.28 | 2 | 2 |
3 | 12 | 1099.72 | 3 | 5.62 | 1360 | 23 | 0.23 / 1312.30 | 2 | 2 |
4 | 12 | 1149.80 | 120 | 5.55 | 1740 | 1159 | 1.39 / 1313.46 | 2 | 2 |
5 | 12 | 1172.12 | 88 | 5.46 | 1691 | 812 | 2.20 / 1314.27 | 2 | 2 |
6 | 7 | 1180.68 | 23 | 9.98 | 1907 | 438 | 2.64 / 1314.71 | 2 | 2 |
7 | 13 | 1270.60 | 36 | 9.99 | 2030 | 730 | 3.37 / 1315.44 | 2 | 2 |
8 | 13 | 1213.92 | 36 | 10.55 | 1984 | 754 | 4.12 / 1316.19 | 2 | 2 |
9 | 13 | 950.20 | 36 | 11.74 | 1638 | 692 | 4.82 / 1316.88 | 2 | 2 |
10 | 8 | 0.12 | 180 | 14.13 | 301 | 766 | 5.58 / 1317.65 | 2 | 6 |
Average= | 5.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.72 | 35 | 14.06 | 464 | 228 | 0.23 / 1305.14 | 2 | 2 |
2 | 3 | 855.68 | -2 | 14.06 | 464 | 0 | 0.00 / 1305.14 | 2 | 2 |
3 | 3 | 969.32 | -1 | 14.06 | 464 | 0 | 0.00 / 1305.14 | 2 | 2 |
4 | 12 | 1135.76 | 3 | 10.89 | 1848 | 60 | 0.29 / 1305.20 | 2 | 2 |
5 | 12 | 2003.84 | 120 | 7.05 | 2929 | 2478 | 2.77 / 1307.68 | 2 | 2 |
6 | 12 | 1989.44 | 88 | 5.67 | 2450 | 1222 | 3.99 / 1308.90 | 2 | 2 |
7 | 7 | 1981.72 | 23 | 9.66 | 3054 | 679 | 4.67 / 1309.58 | 2 | 2 |
8 | 13 | 1581.00 | 36 | 11.26 | 2510 | 1017 | 5.69 / 1310.60 | 2 | 2 |
9 | 13 | 867.68 | 36 | 12.73 | 1539 | 705 | 6.39 / 1311.31 | 2 | 3 |
10 | 8 | 0.00 | 180 | 14.22 | 298 | 763 | 7.15 / 1312.07 | 2 | 12 |
Average= | 5.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.60 | 31 | 14.07 | 465 | 203 | 0.20 / 1299.64 | 2 | 2 |
2 | 3 | 1029.16 | 1 | 11.21 | 1711 | 19 | 0.22 / 1299.66 | 2 | 2 |
3 | 12 | 1096.80 | 3 | 5.48 | 1097 | 18 | 0.24 / 1299.68 | 2 | 2 |
4 | 12 | 1156.80 | 120 | 5.49 | 1496 | 986 | 1.23 / 1300.66 | 2 | 2 |
5 | 12 | 1180.60 | 88 | 5.40 | 1478 | 702 | 1.93 / 1301.36 | 2 | 2 |
6 | 7 | 1189.84 | 23 | 9.71 | 1918 | 428 | 2.36 / 1301.79 | 2 | 2 |
7 | 13 | 1286.68 | 36 | 10.30 | 2065 | 766 | 3.12 / 1302.56 | 2 | 2 |
8 | 13 | 1217.96 | 36 | 10.84 | 1996 | 779 | 3.90 / 1303.34 | 2 | 2 |
9 | 13 | 828.64 | 36 | 12.32 | 1474 | 654 | 4.55 / 1303.99 | 2 | 2 |
10 | 13 | 7.16 | 36 | 14.14 | 311 | 158 | 4.71 / 1304.15 | 2 | 2 |
11 | 8 | 0.12 | 180 | 14.24 | 299 | 766 | 5.48 / 1304.92 | 2 | 10 |
Average= | 5.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.40 | 33 | 14.09 | 447 | 208 | 0.21 / 1294.08 | 2 | 2 |
2 | 3 | 926.28 | -1 | 14.09 | 447 | 0 | 0.00 / 1294.08 | 2 | 2 |
3 | 12 | 1086.60 | 3 | 5.57 | 1137 | 19 | 0.23 / 1294.10 | 2 | 2 |
4 | 12 | 1166.96 | 120 | 5.49 | 1548 | 1020 | 1.25 / 1295.12 | 2 | 2 |
5 | 12 | 1191.48 | 88 | 5.42 | 1546 | 737 | 1.98 / 1295.86 | 2 | 2 |
6 | 7 | 1200.96 | 23 | 9.66 | 1920 | 427 | 2.41 / 1296.29 | 2 | 2 |
7 | 13 | 1284.16 | 36 | 10.23 | 2049 | 755 | 3.17 / 1297.04 | 2 | 2 |
8 | 13 | 1220.08 | 36 | 10.71 | 1979 | 763 | 3.93 / 1297.80 | 2 | 2 |
9 | 13 | 953.44 | 36 | 11.83 | 1639 | 698 | 4.63 / 1298.50 | 2 | 2 |
10 | 13 | 38.76 | 36 | 14.08 | 353 | 179 | 4.81 / 1298.68 | 2 | 2 |
11 | 8 | -0.16 | 180 | 14.25 | 294 | 754 | 5.56 / 1299.44 | 2 | 8 |
Average= | 5.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.20 | 32 | 14.12 | 455 | 206 | 0.21 / 1288.15 | 2 | 2 |
2 | 3 | 1018.56 | 1 | 10.77 | 1694 | 18 | 0.22 / 1288.17 | 2 | 2 |
3 | 12 | 1109.20 | 3 | 5.62 | 1316 | 22 | 0.25 / 1288.19 | 2 | 2 |
4 | 12 | 1154.16 | 120 | 5.55 | 1753 | 1167 | 1.41 / 1289.36 | 2 | 2 |
5 | 12 | 1176.52 | 88 | 5.46 | 1733 | 833 | 2.25 / 1290.19 | 2 | 2 |
6 | 7 | 1185.44 | 23 | 10.05 | 1909 | 441 | 2.69 / 1290.63 | 2 | 2 |
7 | 13 | 1269.24 | 36 | 10.49 | 2035 | 768 | 3.46 / 1291.40 | 2 | 2 |
8 | 13 | 1202.12 | 36 | 10.92 | 1965 | 772 | 4.23 / 1292.17 | 2 | 2 |
9 | 13 | 938.48 | 36 | 11.91 | 1618 | 694 | 4.92 / 1292.87 | 2 | 2 |
10 | 13 | 139.24 | 36 | 13.89 | 504 | 252 | 5.17 / 1293.12 | 2 | 2 |
11 | 8 | 0.08 | 180 | 14.24 | 296 | 759 | 5.93 / 1293.88 | 2 | 11 |
Average= | 5.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.00 | 30 | 14.06 | 462 | 195 | 0.19 / 1280.89 | 2 | 2 |
2 | 10 | 1016.40 | 4 | 12.05 | 1709 | 82 | 0.28 / 1280.98 | 2 | 2 |
3 | 12 | 1081.20 | 3 | 10.94 | 1748 | 57 | 0.33 / 1281.03 | 2 | 2 |
4 | 12 | 2002.80 | 120 | 6.79 | 2858 | 2329 | 2.66 / 1283.36 | 2 | 2 |
5 | 12 | 1989.96 | 88 | 5.64 | 2452 | 1217 | 3.88 / 1284.58 | 2 | 2 |
6 | 7 | 1982.76 | 23 | 9.65 | 3046 | 676 | 4.56 / 1285.25 | 2 | 2 |
7 | 13 | 1725.08 | 36 | 11.21 | 2695 | 1088 | 5.64 / 1286.34 | 2 | 2 |
8 | 13 | 1134.16 | 36 | 12.35 | 1903 | 846 | 6.49 / 1287.19 | 2 | 2 |
9 | 8 | 0.16 | 180 | 14.28 | 294 | 756 | 7.25 / 1287.94 | 2 | 5 |
Average= | 5.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.32 | 31 | 14.01 | 448 | 195 | 0.19 / 1275.48 | 2 | 2 |
2 | 12 | 1088.44 | 3 | 5.47 | 1072 | 18 | 0.21 / 1275.50 | 2 | 2 |
3 | 12 | 1158.68 | 120 | 5.47 | 1437 | 943 | 1.16 / 1276.44 | 2 | 2 |
4 | 12 | 1181.16 | 88 | 5.38 | 1431 | 677 | 1.83 / 1277.12 | 2 | 2 |
5 | 7 | 1189.96 | 23 | 9.37 | 1895 | 408 | 2.24 / 1277.53 | 2 | 2 |
6 | 13 | 1281.00 | 36 | 10.12 | 2050 | 747 | 2.99 / 1278.27 | 2 | 2 |
7 | 13 | 1229.72 | 36 | 10.66 | 1994 | 765 | 3.75 / 1279.04 | 2 | 2 |
8 | 13 | 1099.48 | 36 | 11.28 | 1824 | 741 | 4.49 / 1279.78 | 2 | 2 |
9 | 13 | 17.20 | 36 | 14.11 | 318 | 162 | 4.66 / 1279.94 | 2 | 2 |
10 | 8 | 0.00 | 180 | 14.27 | 295 | 758 | 5.41 / 1280.70 | 2 | 14 |
Average= | 5.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.28 | 33 | 14.00 | 462 | 213 | 0.21 / 1269.98 | 2 | 2 |
2 | 3 | 961.68 | -1 | 14.00 | 462 | 0 | 0.00 / 1269.98 | 2 | 2 |
3 | 3 | 1032.04 | 1 | 10.78 | 1710 | 18 | 0.23 / 1270.00 | 2 | 2 |
4 | 12 | 1107.36 | 3 | 5.55 | 1121 | 19 | 0.25 / 1270.01 | 2 | 2 |
5 | 12 | 1152.24 | 120 | 5.50 | 1516 | 1001 | 1.25 / 1271.02 | 2 | 2 |
6 | 12 | 1172.20 | 88 | 5.41 | 1571 | 748 | 2.00 / 1271.76 | 2 | 2 |
7 | 7 | 1180.56 | 23 | 9.55 | 1890 | 415 | 2.41 / 1272.18 | 2 | 2 |
8 | 13 | 1270.24 | 36 | 10.02 | 2027 | 731 | 3.15 / 1272.91 | 2 | 2 |
9 | 13 | 1219.80 | 36 | 10.45 | 1977 | 744 | 3.89 / 1273.65 | 2 | 2 |
10 | 13 | 1095.56 | 36 | 11.09 | 1812 | 723 | 4.61 / 1274.38 | 2 | 2 |
11 | 13 | 18.56 | 36 | 14.08 | 322 | 163 | 4.78 / 1274.54 | 2 | 2 |
12 | 8 | 0.12 | 180 | 14.26 | 290 | 744 | 5.52 / 1275.28 | 2 | 9 |
Average= | 5.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.16 | 33 | 14.13 | 464 | 216 | 0.22 / 1265.76 | 2 | 2 |
2 | 12 | 1091.56 | 3 | 5.69 | 1481 | 25 | 0.24 / 1265.79 | 2 | 2 |
3 | 12 | 1150.64 | 120 | 6.25 | 1818 | 1363 | 1.61 / 1267.15 | 2 | 2 |
4 | 12 | 1154.16 | 88 | 6.12 | 1823 | 982 | 2.59 / 1268.13 | 2 | 2 |
5 | 7 | 1144.32 | 23 | 10.40 | 1878 | 449 | 3.04 / 1268.58 | 2 | 2 |
6 | 13 | 412.88 | 36 | 13.33 | 893 | 429 | 3.46 / 1269.01 | 2 | 2 |
7 | 8 | 0.20 | 180 | 14.23 | 295 | 756 | 4.22 / 1269.76 | 2 | 9 |
Average= | 5.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.52 | 34 | 14.07 | 458 | 219 | 0.22 / 1257.95 | 2 | 2 |
2 | 3 | 905.12 | -2 | 14.07 | 458 | 0 | 0.00 / 1257.95 | 2 | 2 |
3 | 3 | 1036.04 | 1 | 11.09 | 1713 | 19 | 0.24 / 1257.97 | 2 | 2 |
4 | 12 | 1115.72 | 3 | 10.87 | 1815 | 59 | 0.30 / 1258.03 | 2 | 2 |
5 | 12 | 2000.00 | 120 | 6.75 | 2933 | 2376 | 2.67 / 1260.40 | 2 | 2 |
6 | 12 | 1985.64 | 88 | 5.72 | 2747 | 1383 | 4.06 / 1261.78 | 2 | 2 |
7 | 7 | 1978.16 | 23 | 10.21 | 3062 | 719 | 4.77 / 1262.50 | 2 | 2 |
8 | 13 | 1850.12 | 36 | 11.01 | 2868 | 1137 | 5.91 / 1263.64 | 2 | 2 |
9 | 13 | 1104.44 | 36 | 12.58 | 1880 | 851 | 6.76 / 1264.49 | 2 | 2 |
10 | 13 | 162.92 | 36 | 13.94 | 547 | 275 | 7.04 / 1264.77 | 2 | 2 |
11 | 8 | 0.04 | 180 | 14.31 | 302 | 778 | 7.82 / 1265.54 | 2 | 11 |
Average= | 5.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.08 | 34 | 14.06 | 442 | 211 | 0.21 / 1252.24 | 2 | 2 |
2 | 3 | 913.64 | -1 | 14.06 | 442 | 0 | 0.00 / 1252.24 | 2 | 2 |
3 | 12 | 1087.92 | 3 | 5.54 | 1159 | 19 | 0.23 / 1252.26 | 2 | 2 |
4 | 12 | 1158.44 | 120 | 5.50 | 1573 | 1038 | 1.27 / 1253.30 | 2 | 2 |
5 | 12 | 1183.40 | 88 | 5.43 | 1602 | 765 | 2.03 / 1254.06 | 2 | 2 |
6 | 7 | 1193.32 | 23 | 9.88 | 1916 | 435 | 2.47 / 1254.50 | 2 | 2 |
7 | 13 | 1278.24 | 36 | 10.72 | 2051 | 792 | 3.26 / 1255.29 | 2 | 2 |
8 | 13 | 1213.24 | 36 | 11.15 | 1982 | 796 | 4.06 / 1256.09 | 2 | 2 |
9 | 13 | 938.44 | 36 | 12.18 | 1624 | 712 | 4.77 / 1256.80 | 2 | 2 |
10 | 13 | 24.08 | 36 | 14.11 | 336 | 171 | 4.94 / 1256.97 | 2 | 3 |
11 | 8 | 0.00 | 180 | 14.28 | 296 | 761 | 5.70 / 1257.73 | 2 | 14 |
Average= | 5.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.96 | 31 | 14.03 | 462 | 201 | 0.20 / 1246.31 | 2 | 2 |
2 | 10 | 1002.76 | 5 | 11.84 | 1700 | 101 | 0.30 / 1246.41 | 2 | 2 |
3 | 3 | 933.56 | -1 | 11.84 | 1700 | 0 | 0.10 / 1246.41 | 2 | 2 |
4 | 12 | 1099.76 | 3 | 5.58 | 1280 | 21 | 0.32 / 1246.43 | 2 | 2 |
5 | 12 | 1164.80 | 120 | 5.52 | 1718 | 1138 | 1.46 / 1247.57 | 2 | 2 |
6 | 12 | 1189.84 | 88 | 5.47 | 1750 | 842 | 2.30 / 1248.41 | 2 | 2 |
7 | 7 | 1198.80 | 23 | 9.94 | 1923 | 440 | 2.74 / 1248.85 | 2 | 2 |
8 | 13 | 1292.16 | 36 | 10.58 | 2062 | 785 | 3.53 / 1249.64 | 2 | 2 |
9 | 13 | 1234.64 | 36 | 10.92 | 2006 | 789 | 4.32 / 1250.43 | 2 | 2 |
10 | 13 | 844.68 | 36 | 12.40 | 1486 | 663 | 4.98 / 1251.09 | 2 | 2 |
11 | 13 | 63.20 | 36 | 14.03 | 389 | 196 | 5.18 / 1251.29 | 2 | 2 |
12 | 8 | 0.00 | 180 | 14.27 | 289 | 742 | 5.92 / 1252.03 | 2 | 9 |
Average= | 5.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.48 | 33 | 14.15 | 452 | 211 | 0.21 / 1241.96 | 2 | 2 |
2 | 3 | 937.12 | -1 | 14.15 | 452 | 0 | 0.00 / 1241.96 | 2 | 2 |
3 | 12 | 1092.32 | 3 | 5.58 | 1404 | 24 | 0.23 / 1241.99 | 2 | 2 |
4 | 12 | 1148.28 | 120 | 5.94 | 1820 | 1297 | 1.53 / 1243.28 | 2 | 2 |
5 | 12 | 1156.64 | 88 | 5.90 | 1831 | 951 | 2.48 / 1244.24 | 2 | 2 |
6 | 7 | 1148.52 | 23 | 10.26 | 1889 | 446 | 2.93 / 1244.68 | 2 | 2 |
7 | 13 | 896.36 | 36 | 11.94 | 1565 | 673 | 3.60 / 1245.35 | 2 | 2 |
8 | 8 | 0.40 | 180 | 14.23 | 295 | 756 | 4.36 / 1246.11 | 2 | 9 |
Average= | 5.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.32 | 29 | 14.06 | 445 | 181 | 0.18 / 1234.07 | 2 | 2 |
2 | 10 | 1024.64 | 4 | 12.00 | 1719 | 83 | 0.26 / 1234.15 | 2 | 2 |
3 | 12 | 1109.48 | 3 | 10.70 | 1806 | 58 | 0.32 / 1234.21 | 2 | 2 |
4 | 12 | 2012.68 | 120 | 6.66 | 2964 | 2369 | 2.69 / 1236.57 | 2 | 2 |
5 | 12 | 2000.80 | 88 | 5.77 | 2851 | 1448 | 4.14 / 1238.02 | 2 | 2 |
6 | 7 | 1994.32 | 23 | 10.29 | 3076 | 728 | 4.87 / 1238.75 | 2 | 2 |
7 | 13 | 1864.40 | 36 | 11.33 | 2893 | 1180 | 6.05 / 1239.93 | 2 | 2 |
8 | 13 | 1086.16 | 36 | 12.66 | 1859 | 847 | 6.89 / 1240.78 | 2 | 3 |
9 | 13 | 74.00 | 36 | 14.08 | 408 | 207 | 7.10 / 1240.98 | 2 | 2 |
10 | 8 | -0.16 | 180 | 14.32 | 298 | 768 | 7.87 / 1241.75 | 2 | 6 |
Average= | 5.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.80 | 30 | 14.04 | 437 | 184 | 0.18 / 1228.24 | 2 | 2 |
2 | 10 | 1031.00 | 6 | 11.89 | 1730 | 123 | 0.31 / 1228.36 | 2 | 2 |
3 | 3 | 914.12 | -1 | 11.89 | 1730 | 0 | 0.12 / 1228.36 | 2 | 2 |
4 | 12 | 1078.48 | 3 | 5.55 | 1172 | 20 | 0.33 / 1228.38 | 2 | 2 |
5 | 12 | 1158.48 | 120 | 5.51 | 1583 | 1047 | 1.37 / 1229.43 | 2 | 2 |
6 | 12 | 1180.24 | 88 | 5.45 | 1651 | 792 | 2.17 / 1230.22 | 2 | 2 |
7 | 7 | 1188.52 | 23 | 9.84 | 1919 | 434 | 2.60 / 1230.65 | 2 | 2 |
8 | 13 | 1280.40 | 36 | 10.68 | 2057 | 791 | 3.39 / 1231.45 | 2 | 2 |
9 | 13 | 1206.36 | 36 | 11.18 | 1969 | 792 | 4.18 / 1232.24 | 2 | 2 |
10 | 13 | 932.96 | 36 | 12.25 | 1613 | 711 | 4.89 / 1232.95 | 2 | 2 |
11 | 13 | 52.96 | 36 | 14.05 | 376 | 190 | 5.08 / 1233.14 | 2 | 2 |
12 | 8 | 0.08 | 180 | 14.27 | 290 | 745 | 5.83 / 1233.88 | 2 | 12 |
Average= | 5.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.80 | 32 | 14.03 | 448 | 201 | 0.20 / 1222.60 | 2 | 2 |
2 | 12 | 1112.68 | 3 | 5.64 | 1338 | 23 | 0.22 / 1222.62 | 2 | 2 |
3 | 12 | 1161.80 | 120 | 5.56 | 1818 | 1213 | 1.44 / 1223.83 | 2 | 2 |
4 | 12 | 1184.48 | 88 | 5.73 | 1866 | 941 | 2.38 / 1224.77 | 2 | 2 |
5 | 7 | 1192.40 | 23 | 10.11 | 1907 | 443 | 2.82 / 1225.22 | 2 | 2 |
6 | 13 | 1249.48 | 36 | 10.85 | 2024 | 791 | 3.61 / 1226.01 | 2 | 2 |
7 | 13 | 1159.96 | 36 | 11.28 | 1909 | 775 | 4.39 / 1226.78 | 2 | 2 |
8 | 13 | 561.04 | 36 | 13.11 | 1102 | 520 | 4.91 / 1227.30 | 2 | 2 |
9 | 8 | -0.04 | 180 | 14.24 | 294 | 754 | 5.66 / 1228.05 | 2 | 13 |
Average= | 5.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.00 | 32 | 14.12 | 471 | 213 | 0.21 / 1218.53 | 2 | 2 |
2 | 12 | 1114.36 | 3 | 5.56 | 1639 | 27 | 0.24 / 1218.56 | 2 | 2 |
3 | 12 | 1152.60 | 120 | 6.89 | 1831 | 1514 | 1.75 / 1220.07 | 2 | 2 |
4 | 12 | 1147.60 | 88 | 6.96 | 1835 | 1124 | 2.88 / 1221.20 | 2 | 2 |
5 | 7 | 1134.00 | 23 | 10.55 | 1864 | 452 | 3.33 / 1221.65 | 2 | 2 |
6 | 8 | 0.04 | 180 | 14.21 | 291 | 744 | 4.07 / 1222.39 | 2 | 8 |
Average= | 5.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.28 | 36 | 14.09 | 454 | 230 | 0.23 / 1211.68 | 2 | 2 |
2 | 3 | 838.60 | -3 | 14.09 | 454 | 0 | 0.00 / 1211.68 | 2 | 2 |
3 | 12 | 1095.24 | 3 | 10.63 | 1793 | 57 | 0.29 / 1211.74 | 2 | 2 |
4 | 12 | 2008.16 | 120 | 6.93 | 2993 | 2489 | 2.78 / 1214.23 | 2 | 2 |
5 | 12 | 1992.64 | 88 | 6.35 | 2980 | 1665 | 4.44 / 1215.90 | 2 | 2 |
6 | 7 | 1981.84 | 23 | 10.59 | 3039 | 740 | 5.18 / 1216.64 | 2 | 2 |
7 | 13 | 860.32 | 36 | 13.01 | 1540 | 721 | 5.90 / 1217.36 | 2 | 3 |
8 | 13 | 43.28 | 36 | 14.12 | 365 | 186 | 6.09 / 1217.54 | 2 | 2 |
9 | 8 | 0.04 | 180 | 14.30 | 302 | 777 | 6.87 / 1218.32 | 2 | 11 |
Average= | 5.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.48 | 34 | 14.03 | 450 | 215 | 0.21 / 1206.00 | 2 | 2 |
2 | 3 | 898.88 | -2 | 14.03 | 450 | 0 | 0.00 / 1206.00 | 2 | 2 |
3 | 3 | 1017.44 | 1 | 10.09 | 1682 | 17 | 0.23 / 1206.02 | 2 | 2 |
4 | 12 | 1120.12 | 3 | 5.57 | 1274 | 21 | 0.25 / 1206.04 | 2 | 2 |
5 | 12 | 1150.60 | 120 | 5.53 | 1722 | 1143 | 1.40 / 1207.18 | 2 | 2 |
6 | 12 | 1170.68 | 88 | 5.48 | 1768 | 853 | 2.25 / 1208.03 | 2 | 2 |
7 | 7 | 1178.36 | 23 | 10.11 | 1904 | 443 | 2.69 / 1208.48 | 2 | 2 |
8 | 13 | 1276.64 | 36 | 11.03 | 2059 | 818 | 3.51 / 1209.29 | 2 | 2 |
9 | 13 | 1198.76 | 36 | 11.49 | 1972 | 816 | 4.32 / 1210.11 | 2 | 2 |
10 | 13 | 655.84 | 36 | 13.11 | 1236 | 583 | 4.91 / 1210.69 | 2 | 2 |
11 | 8 | 0.24 | 180 | 14.27 | 296 | 760 | 5.67 / 1211.45 | 2 | 5 |
Average= | 5.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.00 | 33 | 14.06 | 445 | 206 | 0.21 / 1199.95 | 2 | 2 |
2 | 3 | 964.68 | -1 | 14.06 | 445 | 0 | 0.00 / 1199.95 | 2 | 2 |
3 | 3 | 1033.64 | 1 | 10.33 | 1694 | 17 | 0.22 / 1199.96 | 2 | 2 |
4 | 12 | 1098.52 | 3 | 5.60 | 1337 | 22 | 0.25 / 1199.99 | 2 | 2 |
5 | 12 | 1167.28 | 120 | 5.55 | 1771 | 1179 | 1.43 / 1201.17 | 2 | 2 |
6 | 12 | 1188.56 | 88 | 5.49 | 1858 | 898 | 2.32 / 1202.06 | 2 | 2 |
7 | 7 | 1196.16 | 23 | 9.95 | 1934 | 443 | 2.77 / 1202.51 | 2 | 2 |
8 | 13 | 1286.56 | 36 | 10.74 | 2074 | 802 | 3.57 / 1203.31 | 2 | 2 |
9 | 13 | 1203.84 | 36 | 11.21 | 1982 | 800 | 4.37 / 1204.11 | 2 | 2 |
10 | 13 | 940.44 | 36 | 12.21 | 1635 | 719 | 5.09 / 1204.83 | 2 | 2 |
11 | 13 | 49.36 | 36 | 14.02 | 375 | 189 | 5.28 / 1205.02 | 2 | 2 |
12 | 8 | -0.16 | 180 | 14.24 | 300 | 769 | 6.04 / 1205.79 | 2 | 10 |
Average= | 5.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.28 | 33 | 14.14 | 458 | 214 | 0.21 / 1195.71 | 2 | 2 |
2 | 3 | 1017.44 | 1 | 10.31 | 1690 | 17 | 0.23 / 1195.73 | 2 | 2 |
3 | 12 | 1134.08 | 3 | 5.73 | 1679 | 29 | 0.26 / 1195.76 | 2 | 2 |
4 | 12 | 1153.72 | 120 | 6.85 | 1829 | 1503 | 1.76 / 1197.26 | 2 | 2 |
5 | 12 | 1145.48 | 88 | 6.76 | 1834 | 1091 | 2.85 / 1198.35 | 2 | 2 |
6 | 7 | 1130.68 | 23 | 10.40 | 1859 | 445 | 3.30 / 1198.79 | 2 | 2 |
7 | 13 | 53.00 | 36 | 13.99 | 375 | 189 | 3.49 / 1198.98 | 2 | 2 |
8 | 8 | -0.04 | 180 | 14.22 | 296 | 758 | 4.25 / 1199.74 | 2 | 7 |
Average= | 5.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.24 | 28 | 14.02 | 462 | 181 | 0.18 / 1187.68 | 2 | 2 |
2 | 10 | 1030.16 | 5 | 11.91 | 1755 | 105 | 0.29 / 1187.78 | 2 | 2 |
3 | 3 | 1046.60 | 2 | 10.91 | 1756 | 38 | 0.32 / 1187.82 | 2 | 2 |
4 | 3 | 1024.68 | 1 | 10.26 | 1708 | 18 | 0.34 / 1187.84 | 2 | 2 |
5 | 12 | 1108.64 | 3 | 10.32 | 1823 | 56 | 0.40 / 1187.90 | 2 | 2 |
6 | 12 | 2001.00 | 120 | 6.19 | 2822 | 2096 | 2.49 / 1189.99 | 2 | 2 |
7 | 12 | 1990.88 | 88 | 5.73 | 2815 | 1419 | 3.91 / 1191.41 | 2 | 2 |
8 | 7 | 1985.52 | 23 | 10.31 | 3085 | 732 | 4.65 / 1192.14 | 2 | 2 |
9 | 13 | 1869.68 | 36 | 11.40 | 2908 | 1193 | 5.84 / 1193.34 | 2 | 2 |
10 | 13 | 1458.84 | 36 | 12.16 | 2361 | 1034 | 6.87 / 1194.37 | 2 | 2 |
11 | 13 | 279.40 | 36 | 13.78 | 716 | 355 | 7.23 / 1194.73 | 2 | 2 |
12 | 8 | 0.04 | 180 | 14.30 | 299 | 770 | 8.00 / 1195.50 | 2 | 8 |
Average= | 5.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.04 | 29 | 13.98 | 452 | 183 | 0.18 / 1183.39 | 2 | 2 |
2 | 10 | 1033.68 | 5 | 11.75 | 1777 | 104 | 0.29 / 1183.50 | 2 | 2 |
3 | 12 | 1079.12 | 3 | 5.66 | 1473 | 25 | 0.31 / 1183.52 | 2 | 2 |
4 | 12 | 1160.64 | 120 | 6.12 | 1831 | 1345 | 1.66 / 1184.87 | 2 | 2 |
5 | 12 | 1163.52 | 88 | 6.08 | 1846 | 988 | 2.65 / 1185.86 | 2 | 2 |
6 | 7 | 1153.36 | 23 | 10.26 | 1902 | 449 | 3.09 / 1186.30 | 2 | 2 |
7 | 13 | 416.72 | 36 | 13.36 | 910 | 438 | 3.53 / 1186.74 | 2 | 2 |
8 | 8 | 0.08 | 180 | 14.23 | 295 | 756 | 4.29 / 1187.50 | 2 | 13 |
Average= | 5.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.40 | 33 | 14.05 | 453 | 210 | 0.21 / 1179.28 | 2 | 2 |
2 | 12 | 1086.28 | 3 | 5.65 | 1484 | 25 | 0.24 / 1179.31 | 2 | 2 |
3 | 12 | 1155.28 | 120 | 6.05 | 1831 | 1329 | 1.56 / 1180.64 | 2 | 2 |
4 | 12 | 1158.92 | 88 | 6.10 | 1851 | 994 | 2.56 / 1181.63 | 2 | 2 |
5 | 7 | 1149.80 | 23 | 10.13 | 1909 | 445 | 3.00 / 1182.08 | 2 | 2 |
6 | 13 | 294.88 | 36 | 13.52 | 747 | 364 | 3.37 / 1182.44 | 2 | 3 |
7 | 8 | 0.12 | 180 | 14.19 | 302 | 771 | 4.14 / 1183.21 | 2 | 12 |
Average= | 5.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.68 | 29 | 14.06 | 470 | 192 | 0.19 / 1174.78 | 2 | 2 |
2 | 10 | 1033.56 | 5 | 12.05 | 1771 | 107 | 0.30 / 1174.89 | 2 | 2 |
3 | 10 | 1028.88 | 4 | 11.90 | 1783 | 85 | 0.38 / 1174.98 | 2 | 2 |
4 | 3 | 950.40 | -1 | 11.90 | 1783 | 0 | 0.19 / 1174.98 | 2 | 2 |
5 | 3 | 963.16 | -1 | 11.90 | 1783 | 0 | 0.19 / 1174.98 | 2 | 2 |
6 | 12 | 1097.64 | 3 | 5.69 | 1645 | 28 | 0.41 / 1175.00 | 2 | 2 |
7 | 12 | 1165.40 | 120 | 6.78 | 1859 | 1512 | 1.92 / 1176.52 | 2 | 2 |
8 | 12 | 1158.68 | 88 | 6.87 | 1873 | 1132 | 3.06 / 1177.65 | 2 | 2 |
9 | 7 | 1145.04 | 23 | 10.47 | 1903 | 458 | 3.51 / 1178.11 | 2 | 2 |
10 | 13 | 48.32 | 36 | 13.97 | 381 | 192 | 3.71 / 1178.30 | 2 | 3 |
11 | 8 | -0.12 | 180 | 14.16 | 304 | 775 | 4.48 / 1179.07 | 2 | 13 |
Average= | 5.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.20 | 32 | 13.99 | 447 | 200 | 0.20 / 1166.55 | 2 | 2 |
2 | 3 | 938.52 | -1 | 13.99 | 447 | 0 | 0.00 / 1166.55 | 2 | 2 |
3 | 3 | 969.84 | -1 | 13.99 | 447 | 0 | 0.00 / 1166.55 | 2 | 2 |
4 | 12 | 1119.88 | 3 | 10.29 | 1850 | 57 | 0.26 / 1166.61 | 2 | 2 |
5 | 12 | 2002.56 | 120 | 6.35 | 2901 | 2211 | 2.47 / 1168.82 | 2 | 2 |
6 | 12 | 1993.12 | 88 | 5.78 | 2951 | 1501 | 3.97 / 1170.32 | 2 | 2 |
7 | 7 | 1988.04 | 23 | 10.44 | 3074 | 738 | 4.71 / 1171.06 | 2 | 2 |
8 | 13 | 1883.20 | 36 | 11.55 | 2929 | 1218 | 5.92 / 1172.28 | 2 | 2 |
9 | 13 | 1419.16 | 36 | 12.28 | 2317 | 1024 | 6.95 / 1173.30 | 2 | 2 |
10 | 13 | 453.76 | 36 | 13.50 | 993 | 483 | 7.43 / 1173.79 | 2 | 4 |
11 | 8 | 0.00 | 180 | 14.22 | 315 | 806 | 8.24 / 1174.59 | 2 | 12 |
Average= | 5.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.88 | 31 | 13.92 | 462 | 199 | 0.20 / 1162.17 | 2 | 2 |
2 | 3 | 956.04 | -1 | 13.92 | 462 | 0 | 0.00 / 1162.17 | 2 | 2 |
3 | 12 | 1144.32 | 3 | 5.66 | 1434 | 24 | 0.22 / 1162.20 | 2 | 2 |
4 | 12 | 1166.88 | 120 | 5.96 | 1846 | 1320 | 1.54 / 1163.52 | 2 | 2 |
5 | 12 | 1173.08 | 88 | 5.88 | 1871 | 968 | 2.51 / 1164.49 | 2 | 2 |
6 | 7 | 1164.36 | 23 | 10.21 | 1936 | 455 | 2.97 / 1164.94 | 2 | 2 |
7 | 13 | 728.04 | 36 | 12.61 | 1363 | 619 | 3.59 / 1165.56 | 2 | 3 |
8 | 8 | 0.04 | 180 | 14.15 | 312 | 795 | 4.38 / 1166.35 | 2 | 12 |
Average= | 5.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.48 | 31 | 13.95 | 478 | 207 | 0.21 / 1158.00 | 2 | 2 |
2 | 3 | 966.24 | -1 | 13.95 | 478 | 0 | 0.00 / 1158.00 | 2 | 2 |
3 | 12 | 1118.36 | 3 | 5.66 | 1485 | 25 | 0.23 / 1158.02 | 2 | 2 |
4 | 12 | 1151.80 | 120 | 6.04 | 1840 | 1334 | 1.57 / 1159.36 | 2 | 2 |
5 | 12 | 1153.04 | 88 | 6.23 | 1857 | 1018 | 2.58 / 1160.38 | 2 | 2 |
6 | 7 | 1142.80 | 23 | 10.22 | 1912 | 449 | 3.03 / 1160.82 | 2 | 2 |
7 | 13 | 246.56 | 36 | 13.54 | 693 | 338 | 3.37 / 1161.16 | 2 | 4 |
8 | 8 | -0.12 | 180 | 14.09 | 320 | 812 | 4.18 / 1161.97 | 2 | 15 |
Average= | 5.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.76 | 31 | 14.06 | 462 | 201 | 0.20 / 1153.63 | 2 | 2 |
2 | 12 | 1082.64 | 3 | 6.29 | 1597 | 30 | 0.23 / 1153.66 | 2 | 2 |
3 | 12 | 1169.72 | 120 | 6.80 | 1881 | 1535 | 1.77 / 1155.19 | 2 | 2 |
4 | 12 | 1162.64 | 88 | 6.92 | 1887 | 1149 | 2.92 / 1156.34 | 2 | 2 |
5 | 7 | 1149.16 | 23 | 10.46 | 1928 | 464 | 3.38 / 1156.81 | 2 | 2 |
6 | 13 | 11.04 | 36 | 13.98 | 338 | 170 | 3.55 / 1156.98 | 2 | 4 |
7 | 8 | 0.00 | 180 | 14.08 | 322 | 816 | 4.37 / 1157.79 | 2 | 15 |
Average= | 5.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.12 | 31 | 13.93 | 474 | 205 | 0.20 / 1145.78 | 2 | 2 |
2 | 3 | 1032.08 | 1 | 10.59 | 1749 | 19 | 0.22 / 1145.80 | 2 | 2 |
3 | 12 | 1105.80 | 3 | 10.42 | 1841 | 58 | 0.28 / 1145.86 | 2 | 2 |
4 | 12 | 1978.72 | 120 | 6.44 | 2925 | 2260 | 2.54 / 1148.12 | 2 | 2 |
5 | 12 | 1965.16 | 88 | 5.80 | 3035 | 1549 | 4.09 / 1149.67 | 2 | 2 |
6 | 7 | 1958.68 | 23 | 10.59 | 3047 | 742 | 4.83 / 1150.41 | 2 | 2 |
7 | 13 | 1842.12 | 36 | 11.75 | 2878 | 1217 | 6.05 / 1151.63 | 2 | 2 |
8 | 13 | 974.32 | 36 | 12.85 | 1710 | 791 | 6.84 / 1152.42 | 2 | 3 |
9 | 13 | 41.36 | 36 | 14.03 | 385 | 194 | 7.04 / 1152.61 | 2 | 4 |
10 | 8 | -0.16 | 180 | 14.19 | 319 | 815 | 7.85 / 1153.43 | 2 | 17 |
Average= | 5.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.72 | 29 | 13.97 | 454 | 184 | 0.18 / 1141.42 | 2 | 2 |
2 | 3 | 1037.16 | 2 | 10.76 | 1750 | 38 | 0.22 / 1141.45 | 2 | 2 |
3 | 3 | 1017.20 | 1 | 9.97 | 1728 | 17 | 0.24 / 1141.47 | 2 | 2 |
4 | 12 | 1107.00 | 3 | 5.63 | 1439 | 24 | 0.26 / 1141.50 | 2 | 2 |
5 | 12 | 1157.64 | 120 | 5.98 | 1825 | 1310 | 1.57 / 1142.80 | 2 | 2 |
6 | 12 | 1162.60 | 88 | 6.02 | 1859 | 985 | 2.56 / 1143.79 | 2 | 2 |
7 | 7 | 1153.48 | 23 | 10.27 | 1924 | 454 | 3.01 / 1144.24 | 2 | 2 |
8 | 13 | 567.04 | 36 | 12.99 | 1146 | 536 | 3.55 / 1144.78 | 2 | 3 |
9 | 8 | -0.12 | 180 | 14.13 | 313 | 796 | 4.34 / 1145.58 | 2 | 18 |
Average= | 5.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.76 | 31 | 13.90 | 465 | 200 | 0.20 / 1137.17 | 2 | 2 |
2 | 12 | 1081.40 | 3 | 5.69 | 1513 | 26 | 0.23 / 1137.19 | 2 | 2 |
3 | 12 | 1152.68 | 120 | 6.10 | 1843 | 1349 | 1.58 / 1138.54 | 2 | 2 |
4 | 12 | 1154.88 | 88 | 6.35 | 1848 | 1033 | 2.61 / 1139.57 | 2 | 2 |
5 | 7 | 1144.76 | 23 | 10.23 | 1901 | 447 | 3.06 / 1140.02 | 2 | 2 |
6 | 13 | 370.96 | 36 | 13.32 | 867 | 416 | 3.47 / 1140.44 | 2 | 3 |
7 | 8 | 0.00 | 180 | 14.10 | 313 | 794 | 4.27 / 1141.23 | 2 | 14 |
Average= | 5.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.60 | 31 | 14.03 | 467 | 203 | 0.20 / 1132.91 | 2 | 2 |
2 | 12 | 1098.24 | 3 | 5.88 | 1688 | 30 | 0.23 / 1132.94 | 2 | 2 |
3 | 12 | 1151.12 | 120 | 7.14 | 1854 | 1589 | 1.82 / 1134.53 | 2 | 2 |
4 | 12 | 1141.88 | 88 | 7.19 | 1857 | 1175 | 3.00 / 1135.70 | 2 | 2 |
5 | 7 | 1127.56 | 23 | 10.60 | 1878 | 458 | 3.45 / 1136.16 | 2 | 2 |
6 | 8 | 0.20 | 180 | 14.08 | 318 | 806 | 4.26 / 1136.97 | 2 | 12 |
Average= | 5.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.40 | 30 | 13.93 | 472 | 197 | 0.20 / 1125.03 | 2 | 2 |
2 | 12 | 1100.68 | 3 | 10.50 | 1844 | 58 | 0.26 / 1125.09 | 2 | 2 |
3 | 12 | 1982.04 | 120 | 6.37 | 2926 | 2237 | 2.49 / 1127.32 | 2 | 2 |
4 | 12 | 1967.28 | 88 | 5.83 | 3054 | 1567 | 4.06 / 1128.89 | 2 | 2 |
5 | 7 | 1960.40 | 23 | 10.60 | 3052 | 744 | 4.80 / 1129.63 | 2 | 2 |
6 | 13 | 1828.92 | 36 | 11.78 | 2855 | 1211 | 6.01 / 1130.85 | 2 | 2 |
7 | 13 | 1079.36 | 36 | 12.73 | 1851 | 848 | 6.86 / 1131.69 | 2 | 3 |
8 | 13 | 65.96 | 36 | 13.99 | 418 | 211 | 7.07 / 1131.90 | 2 | 4 |
9 | 8 | 0.04 | 180 | 14.19 | 314 | 802 | 7.87 / 1132.71 | 2 | 17 |
Average= | 5.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.64 | 31 | 13.94 | 466 | 201 | 0.20 / 1120.76 | 2 | 2 |
2 | 3 | 951.68 | -1 | 13.94 | 466 | 0 | 0.00 / 1120.76 | 2 | 2 |
3 | 12 | 1097.92 | 3 | 5.64 | 1476 | 25 | 0.23 / 1120.78 | 2 | 2 |
4 | 12 | 1158.56 | 120 | 6.03 | 1846 | 1336 | 1.56 / 1122.12 | 2 | 2 |
5 | 12 | 1159.88 | 88 | 6.18 | 1862 | 1013 | 2.57 / 1123.13 | 2 | 2 |
6 | 7 | 1149.32 | 23 | 10.32 | 1919 | 455 | 3.03 / 1123.59 | 2 | 2 |
7 | 13 | 406.24 | 36 | 13.28 | 922 | 441 | 3.47 / 1124.03 | 2 | 4 |
8 | 8 | -0.16 | 180 | 14.09 | 317 | 804 | 4.28 / 1124.83 | 2 | 15 |
Average= | 5.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.60 | 31 | 13.89 | 472 | 203 | 0.20 / 1116.61 | 2 | 2 |
2 | 12 | 1074.60 | 3 | 5.67 | 1544 | 26 | 0.23 / 1116.64 | 2 | 2 |
3 | 12 | 1153.12 | 120 | 6.28 | 1841 | 1387 | 1.62 / 1118.02 | 2 | 2 |
4 | 12 | 1149.32 | 88 | 6.47 | 1855 | 1056 | 2.67 / 1119.08 | 2 | 2 |
5 | 7 | 1137.24 | 23 | 10.36 | 1903 | 453 | 3.13 / 1119.53 | 2 | 2 |
6 | 13 | 87.08 | 36 | 13.82 | 451 | 224 | 3.35 / 1119.76 | 2 | 4 |
7 | 8 | 0.08 | 180 | 14.08 | 315 | 798 | 4.15 / 1120.56 | 2 | 18 |
Average= | 5.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.00 | 31 | 13.98 | 482 | 209 | 0.21 / 1112.32 | 2 | 2 |
2 | 12 | 1109.24 | 3 | 5.72 | 1714 | 29 | 0.24 / 1112.35 | 2 | 2 |
3 | 12 | 1151.48 | 120 | 7.20 | 1848 | 1597 | 1.83 / 1113.95 | 2 | 2 |
4 | 12 | 1142.16 | 88 | 7.27 | 1860 | 1190 | 3.02 / 1115.14 | 2 | 2 |
5 | 7 | 1128.12 | 23 | 10.60 | 1884 | 459 | 3.48 / 1115.60 | 2 | 2 |
6 | 8 | 0.04 | 180 | 14.07 | 319 | 808 | 4.29 / 1116.41 | 2 | 13 |
Average= | 5.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.56 | 30 | 13.87 | 476 | 198 | 0.20 / 1104.74 | 2 | 2 |
2 | 12 | 1085.68 | 3 | 10.22 | 1818 | 56 | 0.25 / 1104.79 | 2 | 2 |
3 | 12 | 1961.24 | 120 | 6.41 | 2936 | 2258 | 2.51 / 1107.05 | 2 | 2 |
4 | 12 | 1945.48 | 88 | 6.09 | 3059 | 1639 | 4.15 / 1108.69 | 2 | 2 |
5 | 7 | 1936.88 | 23 | 10.65 | 3028 | 742 | 4.89 / 1109.43 | 2 | 2 |
6 | 13 | 1662.96 | 36 | 12.02 | 2642 | 1143 | 6.04 / 1110.58 | 2 | 2 |
7 | 13 | 851.60 | 36 | 13.01 | 1544 | 723 | 6.76 / 1111.30 | 2 | 3 |
8 | 8 | -0.04 | 180 | 14.17 | 320 | 816 | 7.58 / 1112.12 | 2 | 11 |
Average= | 5.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.32 | 27 | 13.87 | 469 | 176 | 0.18 / 1100.47 | 2 | 2 |
2 | 10 | 1015.32 | 7 | 12.06 | 1770 | 149 | 0.33 / 1100.62 | 2 | 2 |
3 | 3 | 954.20 | -1 | 12.06 | 1770 | 0 | 0.15 / 1100.62 | 2 | 2 |
4 | 12 | 1091.64 | 3 | 5.63 | 1458 | 25 | 0.35 / 1100.65 | 2 | 2 |
5 | 12 | 1156.60 | 120 | 6.11 | 1838 | 1348 | 1.70 / 1102.00 | 2 | 2 |
6 | 12 | 1156.44 | 88 | 6.31 | 1868 | 1037 | 2.73 / 1103.03 | 2 | 2 |
7 | 7 | 1145.36 | 23 | 10.43 | 1920 | 461 | 3.20 / 1103.49 | 2 | 2 |
8 | 13 | 115.52 | 36 | 13.79 | 499 | 248 | 3.44 / 1103.74 | 2 | 4 |
9 | 8 | 0.16 | 180 | 14.08 | 315 | 798 | 4.24 / 1104.54 | 2 | 14 |
Average= | 5.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.28 | 30 | 13.89 | 483 | 201 | 0.20 / 1096.46 | 2 | 2 |
2 | 3 | 1028.92 | 1 | 10.56 | 1739 | 18 | 0.22 / 1096.47 | 2 | 2 |
3 | 12 | 1114.72 | 3 | 5.71 | 1569 | 27 | 0.25 / 1096.50 | 2 | 2 |
4 | 12 | 1154.08 | 120 | 6.48 | 1842 | 1432 | 1.68 / 1097.93 | 2 | 2 |
5 | 12 | 1149.68 | 88 | 6.71 | 1858 | 1097 | 2.78 / 1099.03 | 2 | 2 |
6 | 7 | 1137.60 | 23 | 10.49 | 1906 | 460 | 3.24 / 1099.49 | 2 | 2 |
7 | 8 | 0.08 | 180 | 14.07 | 319 | 808 | 4.04 / 1100.30 | 2 | 17 |
Average= | 5.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.08 | 29 | 13.99 | 479 | 194 | 0.19 / 1092.08 | 2 | 2 |
2 | 3 | 1012.00 | 1 | 10.32 | 1743 | 18 | 0.21 / 1092.10 | 2 | 2 |
3 | 12 | 1108.56 | 3 | 5.74 | 1738 | 30 | 0.24 / 1092.13 | 2 | 2 |
4 | 12 | 1151.24 | 120 | 7.36 | 1852 | 1636 | 1.88 / 1093.77 | 2 | 2 |
5 | 12 | 1140.84 | 88 | 7.42 | 1859 | 1214 | 3.09 / 1094.98 | 2 | 2 |
6 | 7 | 1126.52 | 23 | 10.74 | 1883 | 465 | 3.56 / 1095.45 | 2 | 2 |
7 | 8 | -0.16 | 180 | 14.05 | 320 | 809 | 4.37 / 1096.25 | 2 | 14 |
Average= | 5.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.76 | 29 | 13.88 | 480 | 193 | 0.19 / 1084.58 | 2 | 2 |
2 | 12 | 1099.76 | 3 | 10.47 | 1837 | 58 | 0.25 / 1084.64 | 2 | 2 |
3 | 12 | 1971.24 | 120 | 6.43 | 2945 | 2272 | 2.52 / 1086.91 | 2 | 2 |
4 | 12 | 1957.00 | 88 | 6.15 | 3044 | 1647 | 4.17 / 1088.56 | 2 | 2 |
5 | 7 | 1949.12 | 23 | 10.67 | 3028 | 743 | 4.91 / 1089.31 | 2 | 2 |
6 | 13 | 1690.48 | 36 | 11.99 | 2683 | 1158 | 6.07 / 1090.46 | 2 | 2 |
7 | 13 | 637.20 | 36 | 13.25 | 1254 | 598 | 6.67 / 1091.06 | 2 | 4 |
8 | 8 | 0.04 | 180 | 14.14 | 325 | 827 | 7.50 / 1091.89 | 2 | 15 |
Average= | 5.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.36 | 31 | 13.84 | 484 | 208 | 0.21 / 1080.60 | 2 | 2 |
2 | 3 | 924.60 | -1 | 13.84 | 484 | 0 | 0.00 / 1080.60 | 2 | 2 |
3 | 3 | 960.64 | -1 | 13.84 | 484 | 0 | 0.00 / 1080.60 | 2 | 2 |
4 | 12 | 1096.56 | 3 | 5.66 | 1530 | 26 | 0.23 / 1080.62 | 2 | 2 |
5 | 12 | 1163.88 | 120 | 6.37 | 1856 | 1419 | 1.65 / 1082.04 | 2 | 2 |
6 | 12 | 1162.16 | 88 | 6.47 | 1865 | 1062 | 2.71 / 1083.10 | 2 | 2 |
7 | 7 | 1151.44 | 23 | 10.56 | 1926 | 468 | 3.18 / 1083.57 | 2 | 2 |
8 | 8 | 0.20 | 180 | 14.04 | 324 | 819 | 4.00 / 1084.39 | 2 | 10 |
Average= | 5.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.52 | 29 | 13.83 | 478 | 192 | 0.19 / 1076.43 | 2 | 2 |
2 | 12 | 1112.24 | 3 | 5.71 | 1589 | 27 | 0.22 / 1076.46 | 2 | 2 |
3 | 12 | 1154.84 | 120 | 6.38 | 1848 | 1415 | 1.63 / 1077.87 | 2 | 2 |
4 | 12 | 1151.24 | 88 | 6.61 | 1861 | 1083 | 2.72 / 1078.96 | 2 | 2 |
5 | 7 | 1139.56 | 23 | 10.60 | 1908 | 465 | 3.18 / 1079.42 | 2 | 2 |
6 | 13 | 1.84 | 36 | 13.98 | 325 | 164 | 3.35 / 1079.58 | 2 | 6 |
7 | 8 | 0.04 | 180 | 14.03 | 319 | 806 | 4.15 / 1080.39 | 2 | 19 |
Average= | 5.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.04 | 29 | 13.94 | 480 | 194 | 0.19 / 1072.45 | 2 | 2 |
2 | 12 | 1070.96 | 3 | 5.75 | 1774 | 31 | 0.22 / 1072.48 | 2 | 2 |
3 | 12 | 1157.60 | 120 | 7.23 | 1876 | 1628 | 1.85 / 1074.11 | 2 | 2 |
4 | 12 | 1156.52 | 40 | 7.18 | 1885 | 541 | 2.39 / 1074.65 | 2 | 2 |
5 | 7 | 1146.04 | 23 | 10.67 | 1914 | 470 | 2.86 / 1075.12 | 2 | 2 |
6 | 13 | 193.20 | 36 | 13.61 | 615 | 301 | 3.16 / 1075.42 | 2 | 5 |
7 | 8 | -0.04 | 180 | 14.00 | 324 | 816 | 3.98 / 1076.24 | 2 | 17 |
Average= | 5.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.24 | 29 | 13.88 | 473 | 190 | 0.19 / 1066.45 | 2 | 2 |
2 | 12 | 1083.24 | 3 | 10.59 | 1813 | 58 | 0.25 / 1066.50 | 2 | 2 |
3 | 12 | 1955.52 | 120 | 6.86 | 2956 | 2433 | 2.68 / 1068.94 | 2 | 2 |
4 | 12 | 1940.72 | 40 | 6.55 | 2932 | 768 | 3.45 / 1069.71 | 2 | 2 |
5 | 7 | 1929.20 | 23 | 10.63 | 2985 | 730 | 4.18 / 1070.44 | 2 | 2 |
6 | 13 | 1002.04 | 36 | 12.78 | 1756 | 808 | 4.99 / 1071.24 | 2 | 3 |
7 | 13 | 21.36 | 36 | 13.99 | 364 | 183 | 5.17 / 1071.43 | 2 | 6 |
8 | 8 | 0.04 | 180 | 14.09 | 328 | 832 | 6.00 / 1072.26 | 2 | 14 |
Average= | 5.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.12 | 31 | 13.84 | 487 | 209 | 0.21 / 1062.49 | 2 | 2 |
2 | 12 | 1071.56 | 3 | 5.66 | 1506 | 26 | 0.23 / 1062.52 | 2 | 2 |
3 | 12 | 1155.16 | 120 | 6.20 | 1847 | 1374 | 1.61 / 1063.89 | 2 | 2 |
4 | 12 | 1157.72 | 40 | 6.23 | 1856 | 463 | 2.07 / 1064.36 | 2 | 2 |
5 | 7 | 1148.56 | 23 | 10.45 | 1928 | 463 | 2.53 / 1064.82 | 2 | 2 |
6 | 13 | 708.32 | 36 | 12.68 | 1357 | 619 | 3.15 / 1065.44 | 2 | 3 |
7 | 8 | -0.04 | 180 | 14.01 | 324 | 817 | 3.97 / 1066.26 | 2 | 11 |
Average= | 5.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.44 | 29 | 13.83 | 483 | 194 | 0.19 / 1058.48 | 2 | 2 |
2 | 12 | 1095.00 | 3 | 5.71 | 1632 | 28 | 0.22 / 1058.51 | 2 | 2 |
3 | 12 | 1155.24 | 120 | 6.61 | 1853 | 1470 | 1.69 / 1059.98 | 2 | 2 |
4 | 12 | 1156.36 | 40 | 6.63 | 1863 | 494 | 2.19 / 1060.48 | 2 | 2 |
5 | 7 | 1146.56 | 23 | 10.59 | 1927 | 469 | 2.65 / 1060.95 | 2 | 2 |
6 | 13 | 547.12 | 36 | 12.99 | 1121 | 524 | 3.18 / 1061.47 | 2 | 3 |
7 | 8 | 0.00 | 180 | 14.03 | 323 | 816 | 3.99 / 1062.29 | 2 | 5 |
Average= | 5.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.56 | 29 | 13.93 | 481 | 194 | 0.19 / 1054.49 | 2 | 2 |
2 | 12 | 1096.88 | 5 | 6.76 | 1748 | 59 | 0.25 / 1054.55 | 2 | 2 |
3 | 12 | 1160.68 | 120 | 7.57 | 1879 | 1707 | 1.96 / 1056.26 | 2 | 2 |
4 | 12 | 1159.60 | 40 | 7.37 | 1881 | 555 | 2.51 / 1056.81 | 2 | 2 |
5 | 7 | 1148.40 | 23 | 10.72 | 1923 | 474 | 2.99 / 1057.28 | 2 | 2 |
6 | 13 | 39.56 | 36 | 13.88 | 386 | 193 | 3.18 / 1057.48 | 2 | 4 |
7 | 8 | 0.00 | 180 | 13.98 | 323 | 813 | 3.99 / 1058.29 | 2 | 16 |
Average= | 5.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.56 | 29 | 13.88 | 470 | 189 | 0.19 / 1048.82 | 2 | 2 |
2 | 12 | 1081.76 | 5 | 10.96 | 1826 | 100 | 0.29 / 1048.92 | 2 | 2 |
3 | 12 | 1916.68 | 120 | 7.35 | 2887 | 2546 | 2.84 / 1051.47 | 2 | 2 |
4 | 12 | 1900.28 | 40 | 6.84 | 2872 | 786 | 3.62 / 1052.25 | 2 | 2 |
5 | 7 | 1887.48 | 23 | 10.69 | 2939 | 723 | 4.34 / 1052.97 | 2 | 2 |
6 | 13 | 470.96 | 36 | 13.39 | 1024 | 494 | 4.84 / 1053.47 | 2 | 4 |
7 | 8 | 0.16 | 180 | 14.07 | 327 | 828 | 5.67 / 1054.30 | 2 | 18 |
Average= | 5.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.92 | 25 | 13.85 | 497 | 172 | 0.17 / 1044.71 | 2 | 2 |
2 | 10 | 1008.60 | 7 | 12.26 | 1756 | 151 | 0.32 / 1044.86 | 2 | 2 |
3 | 12 | 1103.88 | 5 | 5.65 | 1603 | 45 | 0.37 / 1044.91 | 2 | 2 |
4 | 12 | 1161.00 | 120 | 6.34 | 1855 | 1411 | 1.78 / 1046.32 | 2 | 2 |
5 | 12 | 1164.16 | 40 | 6.35 | 1875 | 476 | 2.26 / 1046.79 | 2 | 2 |
6 | 7 | 1155.48 | 23 | 10.61 | 1942 | 474 | 2.73 / 1047.27 | 2 | 2 |
7 | 13 | 574.04 | 36 | 13.01 | 1163 | 545 | 3.27 / 1047.81 | 2 | 3 |
8 | 8 | 0.08 | 180 | 14.01 | 324 | 817 | 4.09 / 1048.63 | 2 | 15 |
Average= | 5.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.44 | 29 | 13.83 | 496 | 199 | 0.20 / 1040.76 | 2 | 2 |
2 | 12 | 1120.96 | 5 | 5.72 | 1760 | 50 | 0.25 / 1040.81 | 2 | 2 |
3 | 12 | 1151.56 | 120 | 6.80 | 1859 | 1517 | 1.77 / 1042.33 | 2 | 2 |
4 | 12 | 1150.44 | 40 | 6.81 | 1865 | 508 | 2.27 / 1042.84 | 2 | 2 |
5 | 7 | 1139.76 | 23 | 10.71 | 1921 | 473 | 2.75 / 1043.31 | 2 | 2 |
6 | 13 | 358.76 | 36 | 13.34 | 863 | 414 | 3.16 / 1043.72 | 2 | 4 |
7 | 8 | 0.04 | 180 | 14.00 | 323 | 814 | 3.98 / 1044.54 | 2 | 16 |
Average= | 5.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.48 | 29 | 13.89 | 496 | 200 | 0.20 / 1036.73 | 2 | 2 |
2 | 12 | 1094.20 | 5 | 6.84 | 1757 | 60 | 0.26 / 1036.79 | 2 | 2 |
3 | 12 | 1153.28 | 120 | 7.67 | 1874 | 1725 | 1.98 / 1038.51 | 2 | 2 |
4 | 12 | 1149.28 | 40 | 7.53 | 1876 | 565 | 2.55 / 1039.08 | 2 | 2 |
5 | 7 | 1136.92 | 23 | 10.90 | 1916 | 480 | 3.03 / 1039.56 | 2 | 2 |
6 | 13 | 26.72 | 36 | 13.90 | 371 | 186 | 3.22 / 1039.75 | 2 | 5 |
7 | 8 | -0.12 | 180 | 13.98 | 325 | 818 | 4.03 / 1040.56 | 2 | 20 |
Average= | 5.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.80 | 26 | 13.83 | 479 | 172 | 0.17 / 1030.57 | 2 | 2 |
2 | 10 | 1003.32 | 6 | 12.33 | 1766 | 131 | 0.30 / 1030.70 | 2 | 2 |
3 | 3 | 951.84 | -1 | 12.33 | 1766 | 0 | 0.13 / 1030.70 | 2 | 2 |
4 | 12 | 1097.96 | 5 | 11.12 | 1849 | 103 | 0.41 / 1030.80 | 2 | 2 |
5 | 12 | 1910.48 | 120 | 7.47 | 2888 | 2589 | 2.99 / 1033.39 | 2 | 2 |
6 | 12 | 1893.44 | 40 | 6.90 | 2862 | 790 | 3.78 / 1034.18 | 2 | 2 |
7 | 7 | 1880.00 | 23 | 10.77 | 2907 | 720 | 4.50 / 1034.90 | 2 | 2 |
8 | 13 | 713.20 | 36 | 13.12 | 1356 | 640 | 5.14 / 1035.54 | 2 | 4 |
9 | 13 | 3.48 | 36 | 14.05 | 332 | 168 | 5.31 / 1035.71 | 2 | 8 |
10 | 8 | 0.00 | 180 | 14.11 | 324 | 823 | 6.14 / 1036.53 | 2 | 19 |
Average= | 5.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.64 | 32 | 13.86 | 486 | 216 | 0.22 / 1026.63 | 2 | 2 |
2 | 3 | 879.68 | -2 | 13.86 | 486 | 0 | 0.00 / 1026.63 | 2 | 2 |
3 | 3 | 954.04 | -1 | 13.86 | 486 | 0 | 0.00 / 1026.63 | 2 | 2 |
4 | 12 | 1099.84 | 5 | 5.70 | 1683 | 48 | 0.26 / 1026.68 | 2 | 2 |
5 | 12 | 1156.00 | 120 | 6.73 | 1855 | 1498 | 1.76 / 1028.17 | 2 | 2 |
6 | 12 | 1158.40 | 40 | 6.55 | 1866 | 489 | 2.25 / 1028.66 | 2 | 2 |
7 | 7 | 1149.20 | 23 | 10.84 | 1918 | 478 | 2.73 / 1029.14 | 2 | 2 |
8 | 13 | 394.64 | 36 | 13.34 | 912 | 438 | 3.17 / 1029.58 | 2 | 4 |
9 | 8 | -0.16 | 180 | 14.01 | 323 | 815 | 3.98 / 1030.39 | 2 | 14 |
Average= | 5.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.28 | 31 | 13.87 | 471 | 203 | 0.20 / 1022.57 | 2 | 2 |
2 | 3 | 947.32 | -1 | 13.87 | 471 | 0 | 0.00 / 1022.57 | 2 | 2 |
3 | 12 | 1084.72 | 5 | 5.69 | 1644 | 47 | 0.25 / 1022.62 | 2 | 2 |
4 | 12 | 1157.08 | 120 | 6.18 | 1844 | 1368 | 1.62 / 1023.98 | 2 | 2 |
5 | 12 | 1160.08 | 40 | 6.38 | 1867 | 476 | 2.09 / 1024.46 | 2 | 2 |
6 | 7 | 1151.32 | 23 | 10.74 | 1934 | 478 | 2.57 / 1024.94 | 2 | 2 |
7 | 13 | 455.80 | 36 | 13.26 | 995 | 475 | 3.05 / 1025.41 | 2 | 4 |
8 | 13 | 3.44 | 36 | 14.00 | 334 | 168 | 3.21 / 1025.58 | 2 | 8 |
9 | 8 | 0.36 | 180 | 14.02 | 329 | 830 | 4.04 / 1026.41 | 2 | 15 |
Average= | 5.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.56 | 31 | 13.99 | 467 | 203 | 0.20 / 1018.85 | 2 | 2 |
2 | 12 | 1082.08 | 120 | 7.50 | 1768 | 1591 | 1.79 / 1020.44 | 2 | 2 |
3 | 7 | 1071.68 | 23 | 11.23 | 1829 | 472 | 2.27 / 1020.91 | 2 | 2 |
4 | 13 | 784.68 | 36 | 12.63 | 1451 | 660 | 2.93 / 1021.57 | 2 | 3 |
5 | 8 | 0.00 | 180 | 14.04 | 316 | 799 | 3.72 / 1022.37 | 2 | 13 |
Average= | 5.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.24 | 35 | 14.00 | 449 | 220 | 0.22 / 1013.23 | 2 | 2 |
2 | 3 | 813.44 | -3 | 14.00 | 449 | 0 | 0.00 / 1013.23 | 2 | 2 |
3 | 3 | 941.92 | -1 | 14.00 | 449 | 0 | 0.00 / 1013.23 | 2 | 2 |
4 | 12 | 1120.08 | 5 | 10.83 | 1867 | 101 | 0.32 / 1013.33 | 2 | 2 |
5 | 12 | 1964.92 | 120 | 7.60 | 2983 | 2720 | 3.04 / 1016.05 | 2 | 2 |
6 | 7 | 1950.76 | 23 | 10.95 | 3030 | 763 | 3.80 / 1016.81 | 2 | 2 |
7 | 13 | 1044.24 | 36 | 12.78 | 1821 | 838 | 4.64 / 1017.65 | 2 | 3 |
8 | 13 | 55.92 | 36 | 14.04 | 395 | 200 | 4.84 / 1017.85 | 2 | 3 |
9 | 8 | 0.12 | 180 | 14.22 | 309 | 791 | 5.63 / 1018.64 | 2 | 12 |
Average= | 5.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.60 | 30 | 14.07 | 444 | 187 | 0.19 / 1009.39 | 2 | 2 |
2 | 3 | 1027.88 | 1 | 11.26 | 1738 | 20 | 0.21 / 1009.41 | 2 | 2 |
3 | 12 | 1120.64 | 120 | 6.16 | 1764 | 1304 | 1.51 / 1010.71 | 2 | 2 |
4 | 7 | 1119.96 | 23 | 11.13 | 1888 | 483 | 1.99 / 1011.19 | 2 | 2 |
5 | 13 | 1030.20 | 36 | 12.25 | 1768 | 780 | 2.77 / 1011.97 | 2 | 2 |
6 | 13 | 141.12 | 36 | 13.86 | 525 | 262 | 3.04 / 1012.23 | 2 | 3 |
7 | 8 | -0.24 | 180 | 14.18 | 304 | 776 | 3.81 / 1013.01 | 2 | 14 |
Average= | 5.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.56 | 33 | 14.04 | 460 | 213 | 0.21 / 1004.44 | 2 | 2 |
2 | 3 | 945.04 | -1 | 14.04 | 460 | 0 | 0.00 / 1004.44 | 2 | 2 |
3 | 12 | 1227.32 | 100 | 5.75 | 1934 | 1112 | 1.33 / 1005.55 | 2 | 2 |
4 | 7 | 1237.48 | 23 | 11.07 | 2000 | 509 | 1.83 / 1006.06 | 2 | 2 |
5 | 13 | 1302.92 | 36 | 11.53 | 2126 | 882 | 2.72 / 1006.94 | 2 | 2 |
6 | 13 | 1199.24 | 36 | 12.07 | 1992 | 866 | 3.58 / 1007.81 | 2 | 2 |
7 | 13 | 464.96 | 36 | 13.48 | 977 | 474 | 4.06 / 1008.28 | 2 | 2 |
8 | 13 | 16.48 | 36 | 14.14 | 321 | 163 | 4.22 / 1008.44 | 2 | 3 |
9 | 8 | -0.04 | 180 | 14.27 | 294 | 755 | 4.98 / 1009.20 | 2 | 12 |
Average= | 5.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.00 | 30 | 14.15 | 447 | 190 | 0.19 / 1000.32 | 2 | 2 |
2 | 3 | 1066.00 | 2 | 11.86 | 1778 | 42 | 0.23 / 1000.36 | 2 | 2 |
3 | 3 | 1020.04 | 1 | 11.03 | 1698 | 19 | 0.25 / 1000.38 | 2 | 2 |
4 | 12 | 1217.44 | 100 | 7.96 | 1938 | 1543 | 1.79 / 1001.92 | 2 | 2 |
5 | 7 | 1210.36 | 23 | 11.59 | 1997 | 532 | 2.33 / 1002.45 | 2 | 2 |
6 | 13 | 1078.44 | 36 | 12.38 | 1834 | 817 | 3.14 / 1003.27 | 2 | 2 |
7 | 13 | 56.04 | 36 | 14.05 | 381 | 193 | 3.34 / 1003.46 | 2 | 2 |
8 | 8 | 0.16 | 180 | 14.25 | 297 | 762 | 4.10 / 1004.22 | 2 | 8 |
Average= | 5.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.52 | 25 | 14.14 | 455 | 161 | 0.16 / 994.44 | 2 | 2 |
2 | 10 | 1012.72 | 6 | 12.74 | 1708 | 131 | 0.29 / 994.57 | 2 | 2 |
3 | 3 | 1116.20 | 4 | 11.90 | 1859 | 88 | 0.38 / 994.66 | 2 | 2 |
4 | 3 | 1031.20 | 1 | 11.25 | 1712 | 19 | 0.40 / 994.68 | 2 | 2 |
5 | 12 | 1208.60 | 5 | 11.36 | 1978 | 112 | 0.51 / 994.79 | 2 | 2 |
6 | 12 | 1994.36 | 100 | 9.37 | 3047 | 2855 | 3.37 / 997.65 | 2 | 2 |
7 | 7 | 1979.96 | 23 | 11.22 | 3054 | 788 | 4.15 / 998.43 | 2 | 2 |
8 | 13 | 881.44 | 36 | 13.17 | 1568 | 743 | 4.90 / 999.18 | 2 | 3 |
9 | 13 | 44.60 | 36 | 14.18 | 364 | 186 | 5.08 / 999.36 | 2 | 2 |
10 | 8 | 0.08 | 180 | 14.36 | 295 | 763 | 5.85 / 1000.13 | 2 | 13 |
Average= | 5.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.04 | 33 | 14.16 | 438 | 205 | 0.20 / 984.82 | 2 | 2 |
2 | 3 | 905.52 | -2 | 14.16 | 438 | 0 | 0.00 / 984.82 | 2 | 2 |
3 | 3 | 1024.00 | 1 | 11.06 | 1699 | 19 | 0.22 / 984.84 | 2 | 2 |
4 | 12 | 1220.04 | 19 | 8.20 | 1907 | 297 | 0.52 / 985.14 | 2 | 2 |
5 | 12 | 1993.12 | 200 | 5.72 | 2595 | 2969 | 3.49 / 988.11 | 2 | 2 |
6 | 12 | 1992.72 | 100 | 5.75 | 2968 | 1707 | 5.20 / 989.81 | 2 | 2 |
7 | 7 | 1992.60 | 23 | 10.96 | 3055 | 770 | 5.97 / 990.58 | 2 | 2 |
8 | 13 | 1903.40 | 36 | 11.86 | 2949 | 1259 | 7.23 / 991.84 | 2 | 2 |
9 | 13 | 1508.44 | 36 | 12.49 | 2436 | 1095 | 8.32 / 992.94 | 2 | 2 |
10 | 13 | 616.96 | 36 | 13.49 | 1191 | 578 | 8.90 / 993.52 | 2 | 2 |
11 | 8 | -0.08 | 180 | 14.36 | 295 | 763 | 9.66 / 994.28 | 2 | 11 |
Average= | 5.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.84 | 31 | 14.16 | 450 | 198 | 0.20 / 975.92 | 2 | 2 |
2 | 3 | 1044.80 | 1 | 11.64 | 1743 | 20 | 0.22 / 975.94 | 2 | 2 |
3 | 12 | 1214.20 | 19 | 8.39 | 1889 | 301 | 0.52 / 976.24 | 2 | 2 |
4 | 12 | 1998.84 | 150 | 5.73 | 2506 | 2154 | 2.67 / 978.39 | 2 | 2 |
5 | 12 | 1998.08 | 100 | 5.71 | 2762 | 1577 | 4.25 / 979.97 | 2 | 2 |
6 | 7 | 1997.72 | 23 | 10.76 | 3050 | 755 | 5.00 / 980.72 | 2 | 2 |
7 | 13 | 1911.40 | 36 | 11.67 | 2966 | 1246 | 6.25 / 981.97 | 2 | 2 |
8 | 13 | 1643.08 | 36 | 12.25 | 2616 | 1154 | 7.40 / 983.12 | 2 | 2 |
9 | 13 | 621.32 | 36 | 13.47 | 1194 | 579 | 7.98 / 983.70 | 2 | 2 |
10 | 13 | 10.12 | 36 | 14.25 | 309 | 159 | 8.14 / 983.86 | 2 | 2 |
11 | 8 | 0.00 | 180 | 14.39 | 292 | 756 | 8.90 / 984.62 | 2 | 12 |
Average= | 5.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.56 | 31 | 14.18 | 437 | 192 | 0.19 / 967.37 | 2 | 2 |
2 | 12 | 1222.36 | 19 | 8.20 | 1926 | 300 | 0.49 / 967.67 | 2 | 2 |
3 | 12 | 1992.72 | 150 | 5.70 | 2450 | 2095 | 2.59 / 969.76 | 2 | 2 |
4 | 12 | 1992.52 | 100 | 5.70 | 2683 | 1529 | 4.12 / 971.29 | 2 | 2 |
5 | 7 | 1992.44 | 23 | 10.74 | 3040 | 751 | 4.87 / 972.04 | 2 | 2 |
6 | 13 | 1908.72 | 36 | 11.65 | 2966 | 1244 | 6.11 / 973.29 | 2 | 2 |
7 | 13 | 1513.88 | 36 | 12.40 | 2434 | 1087 | 7.20 / 974.37 | 2 | 2 |
8 | 13 | 624.56 | 36 | 13.46 | 1204 | 583 | 7.78 / 974.96 | 2 | 2 |
9 | 8 | 0.04 | 180 | 14.35 | 296 | 765 | 8.55 / 975.72 | 2 | 9 |
Average= | 5.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.08 | 33 | 14.18 | 430 | 201 | 0.20 / 959.35 | 2 | 2 |
2 | 3 | 939.28 | -1 | 14.18 | 430 | 0 | 0.00 / 959.35 | 2 | 2 |
3 | 12 | 1218.24 | 20 | 8.52 | 1934 | 330 | 0.53 / 959.68 | 2 | 2 |
4 | 12 | 1972.80 | 100 | 5.75 | 2509 | 1443 | 1.97 / 961.12 | 2 | 2 |
5 | 12 | 1972.24 | 100 | 5.69 | 2624 | 1493 | 3.47 / 962.62 | 2 | 2 |
6 | 7 | 1972.08 | 23 | 10.66 | 3008 | 738 | 4.20 / 963.35 | 2 | 2 |
7 | 13 | 1890.68 | 36 | 11.47 | 2923 | 1207 | 5.41 / 964.56 | 2 | 2 |
8 | 13 | 1495.08 | 36 | 12.30 | 2402 | 1064 | 6.47 / 965.62 | 2 | 2 |
9 | 13 | 748.36 | 36 | 13.30 | 1371 | 656 | 7.13 / 966.28 | 2 | 3 |
10 | 13 | 6.12 | 36 | 14.26 | 298 | 153 | 7.28 / 966.43 | 2 | 3 |
11 | 8 | 0.08 | 180 | 14.39 | 286 | 741 | 8.02 / 967.17 | 2 | 11 |
Average= | 5.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.84 | 33 | 14.17 | 452 | 211 | 0.21 / 951.40 | 2 | 2 |
2 | 12 | 1203.24 | 20 | 8.26 | 1890 | 312 | 0.52 / 951.71 | 2 | 2 |
3 | 12 | 1986.68 | 100 | 5.78 | 2593 | 1499 | 2.02 / 953.21 | 2 | 2 |
4 | 12 | 1986.80 | 100 | 5.76 | 2862 | 1649 | 3.67 / 954.86 | 2 | 2 |
5 | 7 | 1986.80 | 23 | 10.82 | 3037 | 756 | 4.43 / 955.62 | 2 | 2 |
6 | 13 | 1903.20 | 36 | 11.56 | 2946 | 1226 | 5.65 / 956.84 | 2 | 2 |
7 | 13 | 1501.96 | 36 | 12.33 | 2417 | 1073 | 6.73 / 957.91 | 2 | 2 |
8 | 13 | 486.84 | 36 | 13.58 | 1005 | 491 | 7.22 / 958.41 | 2 | 2 |
9 | 8 | -0.04 | 180 | 14.35 | 288 | 744 | 7.96 / 959.15 | 2 | 10 |
Average= | 5.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.92 | 33 | 14.16 | 458 | 214 | 0.21 / 941.96 | 2 | 2 |
2 | 12 | 1197.12 | 21 | 8.40 | 1879 | 331 | 0.55 / 942.30 | 2 | 2 |
3 | 12 | 1987.76 | 200 | 5.78 | 2796 | 3232 | 3.78 / 945.53 | 2 | 2 |
4 | 12 | 1985.72 | 100 | 6.49 | 3027 | 1965 | 5.74 / 947.49 | 2 | 2 |
5 | 7 | 1977.48 | 23 | 11.16 | 3065 | 787 | 6.53 / 948.28 | 2 | 2 |
6 | 13 | 1710.36 | 36 | 12.14 | 2699 | 1180 | 7.71 / 949.46 | 2 | 2 |
7 | 13 | 948.08 | 36 | 13.08 | 1666 | 784 | 8.49 / 950.24 | 2 | 3 |
8 | 13 | 61.04 | 36 | 14.14 | 388 | 198 | 8.69 / 950.44 | 2 | 2 |
9 | 8 | -0.16 | 180 | 14.38 | 289 | 748 | 9.44 / 951.19 | 2 | 11 |
Average= | 5.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.92 | 31 | 14.16 | 450 | 198 | 0.20 / 932.27 | 2 | 2 |
2 | 3 | 1040.32 | 1 | 11.64 | 1740 | 20 | 0.22 / 932.29 | 2 | 2 |
3 | 12 | 1215.00 | 21 | 8.35 | 1919 | 336 | 0.55 / 932.63 | 2 | 2 |
4 | 12 | 1985.04 | 200 | 5.76 | 2716 | 3129 | 3.68 / 935.76 | 2 | 2 |
5 | 12 | 1986.04 | 100 | 5.94 | 3076 | 1827 | 5.51 / 937.58 | 2 | 2 |
6 | 7 | 1982.28 | 23 | 11.21 | 3032 | 782 | 6.29 / 938.37 | 2 | 2 |
7 | 13 | 1884.04 | 36 | 11.94 | 2940 | 1264 | 7.56 / 939.63 | 2 | 2 |
8 | 13 | 1332.12 | 36 | 12.71 | 2203 | 1008 | 8.56 / 940.64 | 2 | 2 |
9 | 13 | 276.24 | 36 | 13.85 | 706 | 352 | 8.92 / 940.99 | 2 | 2 |
10 | 8 | 0.16 | 180 | 14.37 | 294 | 760 | 9.68 / 941.75 | 2 | 9 |
Average= | 5.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.12 | 33 | 14.22 | 438 | 206 | 0.21 / 923.04 | 2 | 2 |
2 | 3 | 941.56 | -1 | 14.22 | 438 | 0 | 0.00 / 923.04 | 2 | 2 |
3 | 12 | 1218.24 | 23 | 8.35 | 1927 | 370 | 0.58 / 923.41 | 2 | 2 |
4 | 12 | 1964.88 | 200 | 5.74 | 2661 | 3055 | 3.63 / 926.47 | 2 | 2 |
5 | 12 | 1965.40 | 60 | 5.77 | 2975 | 1030 | 4.66 / 927.50 | 2 | 2 |
6 | 7 | 1965.60 | 23 | 10.95 | 3010 | 758 | 5.42 / 928.25 | 2 | 2 |
7 | 13 | 1884.52 | 36 | 11.79 | 2924 | 1241 | 6.66 / 929.49 | 2 | 2 |
8 | 13 | 1492.16 | 36 | 12.53 | 2401 | 1083 | 7.74 / 930.58 | 2 | 3 |
9 | 13 | 584.96 | 36 | 13.53 | 1144 | 557 | 8.30 / 931.13 | 2 | 3 |
10 | 13 | 41.36 | 36 | 14.20 | 358 | 183 | 8.48 / 931.32 | 2 | 2 |
11 | 8 | -0.12 | 180 | 14.39 | 292 | 756 | 9.24 / 932.07 | 2 | 12 |
Average= | 5.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.48 | 33 | 14.18 | 448 | 210 | 0.21 / 914.12 | 2 | 2 |
2 | 12 | 1185.04 | 23 | 8.30 | 1867 | 356 | 0.57 / 914.48 | 2 | 2 |
3 | 12 | 1965.92 | 200 | 5.71 | 2526 | 2885 | 3.45 / 917.36 | 2 | 2 |
4 | 12 | 1965.44 | 60 | 5.71 | 2831 | 970 | 4.42 / 918.33 | 2 | 2 |
5 | 7 | 1965.16 | 23 | 10.89 | 3019 | 756 | 5.18 / 919.09 | 2 | 2 |
6 | 13 | 1873.60 | 36 | 11.76 | 2902 | 1229 | 6.41 / 920.32 | 2 | 2 |
7 | 13 | 1599.52 | 36 | 12.41 | 2549 | 1139 | 7.54 / 921.46 | 2 | 2 |
8 | 13 | 689.08 | 36 | 13.42 | 1291 | 624 | 8.17 / 922.08 | 2 | 2 |
9 | 8 | -0.12 | 180 | 14.38 | 292 | 756 | 8.92 / 922.83 | 2 | 9 |
Average= | 5.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.28 | 33 | 14.20 | 452 | 212 | 0.21 / 905.64 | 2 | 2 |
2 | 12 | 1207.24 | 24 | 8.23 | 1899 | 375 | 0.59 / 906.02 | 2 | 2 |
3 | 12 | 1966.84 | 170 | 5.72 | 2506 | 2437 | 3.02 / 908.46 | 2 | 2 |
4 | 12 | 1963.76 | 60 | 5.71 | 2774 | 950 | 3.97 / 909.41 | 2 | 2 |
5 | 7 | 1962.36 | 23 | 11.01 | 3004 | 761 | 4.73 / 910.17 | 2 | 2 |
6 | 13 | 1860.68 | 36 | 11.73 | 2884 | 1218 | 5.95 / 911.38 | 2 | 2 |
7 | 13 | 1731.72 | 36 | 12.14 | 2723 | 1190 | 7.14 / 912.58 | 2 | 2 |
8 | 13 | 645.24 | 36 | 13.47 | 1222 | 593 | 7.74 / 913.17 | 2 | 3 |
9 | 8 | 0.08 | 180 | 14.39 | 287 | 743 | 8.48 / 913.91 | 2 | 6 |
Average= | 5.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.48 | 33 | 14.22 | 441 | 207 | 0.21 / 897.27 | 2 | 2 |
2 | 12 | 1196.40 | 24 | 8.41 | 1902 | 384 | 0.59 / 897.66 | 2 | 2 |
3 | 12 | 1949.44 | 170 | 5.72 | 2549 | 2479 | 3.07 / 900.13 | 2 | 2 |
4 | 12 | 1947.96 | 60 | 5.73 | 2831 | 973 | 4.04 / 901.11 | 2 | 2 |
5 | 7 | 1947.28 | 23 | 11.06 | 3006 | 765 | 4.81 / 901.87 | 2 | 2 |
6 | 13 | 1857.64 | 36 | 11.81 | 2889 | 1228 | 6.04 / 903.10 | 2 | 2 |
7 | 13 | 1449.16 | 36 | 12.59 | 2356 | 1068 | 7.10 / 904.17 | 2 | 2 |
8 | 13 | 531.36 | 36 | 13.60 | 1062 | 520 | 7.62 / 904.69 | 2 | 2 |
9 | 8 | 0.32 | 180 | 14.39 | 287 | 743 | 8.37 / 905.43 | 2 | 9 |
Average= | 5.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.76 | 31 | 14.18 | 456 | 200 | 0.20 / 888.78 | 2 | 2 |
2 | 3 | 1030.20 | 1 | 11.32 | 1729 | 20 | 0.22 / 888.80 | 2 | 2 |
3 | 3 | 1015.76 | 1 | 10.47 | 1712 | 18 | 0.24 / 888.82 | 2 | 2 |
4 | 12 | 1210.00 | 25 | 8.09 | 1922 | 389 | 0.63 / 889.21 | 2 | 2 |
5 | 12 | 1951.88 | 170 | 5.73 | 2540 | 2474 | 3.10 / 891.68 | 2 | 2 |
6 | 12 | 1952.64 | 60 | 5.71 | 2809 | 962 | 4.06 / 892.65 | 2 | 2 |
7 | 7 | 1953.20 | 23 | 11.11 | 3019 | 771 | 4.83 / 893.42 | 2 | 2 |
8 | 13 | 1871.60 | 36 | 11.89 | 2902 | 1242 | 6.08 / 894.66 | 2 | 2 |
9 | 13 | 1592.28 | 36 | 12.51 | 2544 | 1146 | 7.22 / 895.81 | 2 | 2 |
10 | 13 | 501.52 | 36 | 13.63 | 1023 | 502 | 7.72 / 896.31 | 2 | 3 |
11 | 8 | -0.08 | 180 | 14.38 | 293 | 758 | 8.48 / 897.07 | 2 | 9 |
Average= | 5.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.64 | 31 | 14.20 | 452 | 199 | 0.20 / 880.81 | 2 | 2 |
2 | 12 | 1218.52 | 26 | 8.44 | 1918 | 421 | 0.62 / 881.23 | 2 | 2 |
3 | 12 | 1924.32 | 170 | 5.74 | 2586 | 2523 | 3.14 / 883.76 | 2 | 2 |
4 | 12 | 1924.40 | 30 | 5.73 | 2805 | 482 | 3.63 / 884.24 | 2 | 2 |
5 | 7 | 1924.24 | 23 | 11.15 | 2957 | 758 | 4.38 / 885.00 | 2 | 2 |
6 | 13 | 1828.32 | 36 | 11.88 | 2851 | 1219 | 5.60 / 886.22 | 2 | 2 |
7 | 13 | 1554.04 | 36 | 12.53 | 2481 | 1119 | 6.72 / 887.33 | 2 | 2 |
8 | 13 | 481.44 | 36 | 13.66 | 996 | 490 | 7.21 / 887.82 | 2 | 2 |
9 | 8 | 0.12 | 180 | 14.38 | 293 | 758 | 7.97 / 888.58 | 2 | 4 |
Average= | 5.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.44 | 32 | 14.19 | 447 | 203 | 0.20 / 872.77 | 2 | 2 |
2 | 3 | 963.72 | -1 | 14.19 | 447 | 0 | 0.00 / 872.77 | 2 | 2 |
3 | 3 | 1029.56 | 1 | 11.11 | 1745 | 19 | 0.22 / 872.79 | 2 | 2 |
4 | 12 | 1219.52 | 26 | 7.82 | 1912 | 389 | 0.61 / 873.18 | 2 | 2 |
5 | 12 | 1951.00 | 170 | 5.73 | 2566 | 2500 | 3.11 / 875.68 | 2 | 2 |
6 | 12 | 1951.72 | 30 | 5.71 | 2774 | 475 | 3.59 / 876.15 | 2 | 2 |
7 | 7 | 1951.84 | 23 | 11.14 | 2999 | 768 | 4.35 / 876.92 | 2 | 2 |
8 | 13 | 1864.80 | 36 | 11.94 | 2904 | 1248 | 5.60 / 878.17 | 2 | 2 |
9 | 13 | 1596.92 | 36 | 12.53 | 2550 | 1150 | 6.75 / 879.32 | 2 | 2 |
10 | 13 | 525.44 | 36 | 13.59 | 1071 | 524 | 7.28 / 879.84 | 2 | 3 |
11 | 8 | -0.04 | 180 | 14.36 | 298 | 770 | 8.05 / 880.61 | 2 | 10 |
Average= | 5.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.72 | 32 | 14.19 | 453 | 206 | 0.21 / 865.17 | 2 | 2 |
2 | 12 | 1175.00 | 28 | 8.23 | 1852 | 427 | 0.63 / 865.60 | 2 | 2 |
3 | 12 | 1883.80 | 130 | 5.77 | 2646 | 1985 | 2.62 / 867.59 | 2 | 2 |
4 | 12 | 1884.32 | 40 | 5.71 | 2789 | 637 | 3.25 / 868.22 | 2 | 2 |
5 | 7 | 1884.48 | 50 | 9.86 | 2902 | 1431 | 4.68 / 869.65 | 2 | 2 |
6 | 13 | 1756.92 | 36 | 12.06 | 2749 | 1194 | 5.88 / 870.85 | 2 | 2 |
7 | 13 | 889.60 | 36 | 13.15 | 1595 | 755 | 6.63 / 871.60 | 2 | 3 |
8 | 13 | 53.04 | 36 | 14.17 | 382 | 195 | 6.83 / 871.80 | 2 | 3 |
9 | 8 | 0.00 | 180 | 14.36 | 297 | 768 | 7.60 / 872.57 | 2 | 11 |
Average= | 4.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.16 | 31 | 14.22 | 451 | 199 | 0.20 / 857.30 | 2 | 2 |
2 | 3 | 1039.32 | 1 | 11.67 | 1740 | 20 | 0.22 / 857.32 | 2 | 2 |
3 | 12 | 1202.68 | 28 | 8.19 | 1912 | 438 | 0.66 / 857.75 | 2 | 2 |
4 | 12 | 1919.28 | 130 | 5.78 | 2727 | 2049 | 2.71 / 859.80 | 2 | 2 |
5 | 12 | 1920.16 | 40 | 5.77 | 2888 | 667 | 3.37 / 860.47 | 2 | 2 |
6 | 7 | 1920.64 | 50 | 9.99 | 2965 | 1481 | 4.85 / 861.95 | 2 | 2 |
7 | 13 | 1791.32 | 36 | 12.09 | 2808 | 1222 | 6.08 / 863.17 | 2 | 2 |
8 | 13 | 1041.76 | 36 | 13.04 | 1801 | 845 | 6.92 / 864.02 | 2 | 3 |
9 | 13 | 46.44 | 36 | 14.18 | 374 | 191 | 7.11 / 864.21 | 2 | 3 |
10 | 8 | -0.20 | 180 | 14.36 | 294 | 760 | 7.87 / 864.97 | 2 | 11 |
Average= | 4.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.32 | 32 | 14.22 | 444 | 202 | 0.20 / 849.53 | 2 | 2 |
2 | 3 | 968.60 | -1 | 14.22 | 444 | 0 | 0.00 / 849.53 | 2 | 2 |
3 | 3 | 1025.64 | 1 | 11.11 | 1718 | 19 | 0.22 / 849.55 | 2 | 2 |
4 | 12 | 1229.20 | 30 | 8.40 | 1940 | 489 | 0.71 / 850.04 | 2 | 2 |
5 | 12 | 1923.16 | 130 | 5.78 | 2679 | 2013 | 2.72 / 852.05 | 2 | 2 |
6 | 12 | 1923.48 | 40 | 5.75 | 2814 | 647 | 3.37 / 852.70 | 2 | 2 |
7 | 7 | 1923.60 | 23 | 11.04 | 2970 | 754 | 4.12 / 853.45 | 2 | 2 |
8 | 13 | 1836.56 | 36 | 12.05 | 2872 | 1246 | 5.37 / 854.70 | 2 | 2 |
9 | 13 | 1558.12 | 36 | 12.62 | 2497 | 1134 | 6.50 / 855.83 | 2 | 2 |
10 | 13 | 475.16 | 36 | 13.67 | 1000 | 492 | 7.00 / 856.32 | 2 | 2 |
11 | 8 | -0.12 | 180 | 14.37 | 299 | 773 | 7.77 / 857.10 | 2 | 6 |
Average= | 4.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.32 | 32 | 14.18 | 458 | 208 | 0.21 / 842.01 | 2 | 2 |
2 | 12 | 1201.84 | 30 | 7.52 | 1890 | 426 | 0.63 / 842.43 | 2 | 2 |
3 | 12 | 1956.76 | 130 | 5.71 | 2454 | 1822 | 2.46 / 844.25 | 2 | 2 |
4 | 12 | 1956.28 | 40 | 5.68 | 2556 | 581 | 3.04 / 844.83 | 2 | 2 |
5 | 7 | 1956.16 | 23 | 10.87 | 3011 | 753 | 3.79 / 845.59 | 2 | 2 |
6 | 13 | 1869.08 | 36 | 11.98 | 2912 | 1256 | 5.05 / 846.84 | 2 | 2 |
7 | 13 | 1454.68 | 36 | 12.72 | 2370 | 1085 | 6.13 / 847.93 | 2 | 2 |
8 | 13 | 692.28 | 36 | 13.46 | 1305 | 632 | 6.76 / 848.56 | 2 | 3 |
9 | 8 | 0.20 | 180 | 14.36 | 296 | 765 | 7.53 / 849.33 | 2 | 15 |
Average= | 4.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.68 | 31 | 14.26 | 442 | 195 | 0.20 / 835.00 | 2 | 2 |
2 | 12 | 1218.48 | 26 | 7.42 | 1915 | 369 | 0.56 / 835.37 | 2 | 2 |
3 | 12 | 2002.56 | 90 | 5.75 | 2476 | 1281 | 1.85 / 836.65 | 2 | 2 |
4 | 12 | 2005.68 | 40 | 5.66 | 2482 | 562 | 2.41 / 837.22 | 2 | 2 |
5 | 7 | 2007.48 | 23 | 10.72 | 3077 | 759 | 3.17 / 837.97 | 2 | 2 |
6 | 13 | 1924.44 | 36 | 11.90 | 2972 | 1273 | 4.44 / 839.25 | 2 | 2 |
7 | 13 | 1656.32 | 36 | 12.53 | 2638 | 1190 | 5.63 / 840.44 | 2 | 2 |
8 | 13 | 631.24 | 36 | 13.52 | 1218 | 593 | 6.22 / 841.03 | 2 | 3 |
9 | 8 | 0.00 | 180 | 14.36 | 297 | 768 | 6.99 / 841.80 | 2 | 9 |
Average= | 4.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.84 | 31 | 14.23 | 444 | 196 | 0.20 / 827.85 | 2 | 2 |
2 | 12 | 1216.08 | 26 | 7.21 | 1912 | 358 | 0.55 / 828.21 | 2 | 2 |
3 | 12 | 2000.40 | 90 | 5.75 | 2439 | 1262 | 1.82 / 829.47 | 2 | 2 |
4 | 12 | 2005.00 | 40 | 5.66 | 2430 | 550 | 2.37 / 830.02 | 2 | 2 |
5 | 7 | 2007.68 | 23 | 10.69 | 3084 | 758 | 3.12 / 830.78 | 2 | 2 |
6 | 13 | 1938.20 | 36 | 11.86 | 3000 | 1281 | 4.41 / 832.06 | 2 | 2 |
7 | 13 | 1675.32 | 36 | 12.51 | 2669 | 1202 | 5.61 / 833.26 | 2 | 2 |
8 | 13 | 901.80 | 36 | 13.25 | 1612 | 769 | 6.38 / 834.03 | 2 | 3 |
9 | 8 | 0.08 | 180 | 14.37 | 301 | 779 | 7.16 / 834.81 | 2 | 10 |
Average= | 4.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.36 | 31 | 14.18 | 456 | 200 | 0.20 / 821.60 | 2 | 2 |
2 | 12 | 1169.32 | 25 | 7.44 | 1869 | 348 | 0.55 / 821.95 | 2 | 2 |
3 | 12 | 2001.56 | 56 | 5.81 | 2591 | 843 | 1.39 / 822.79 | 2 | 2 |
4 | 12 | 2004.40 | 32 | 5.69 | 2471 | 450 | 1.84 / 823.24 | 2 | 2 |
5 | 7 | 2006.32 | 23 | 10.60 | 3081 | 751 | 2.59 / 823.99 | 2 | 2 |
6 | 13 | 1897.32 | 36 | 12.03 | 2950 | 1278 | 3.87 / 825.27 | 2 | 2 |
7 | 13 | 1465.04 | 36 | 12.67 | 2378 | 1085 | 4.95 / 826.35 | 2 | 2 |
8 | 13 | 535.16 | 36 | 13.60 | 1086 | 532 | 5.49 / 826.88 | 2 | 3 |
9 | 8 | -0.12 | 180 | 14.34 | 298 | 769 | 6.26 / 827.65 | 2 | 10 |
Average= | 4.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.44 | 31 | 14.21 | 454 | 200 | 0.20 / 815.17 | 2 | 2 |
2 | 12 | 1168.96 | 25 | 7.33 | 1841 | 337 | 0.54 / 815.51 | 2 | 2 |
3 | 12 | 2001.96 | 56 | 5.79 | 2540 | 824 | 1.36 / 816.33 | 2 | 2 |
4 | 12 | 2004.88 | 32 | 5.66 | 2396 | 434 | 1.79 / 816.77 | 2 | 2 |
5 | 7 | 2006.76 | 23 | 10.50 | 3072 | 742 | 2.54 / 817.51 | 2 | 2 |
6 | 13 | 1891.04 | 36 | 12.01 | 2953 | 1277 | 3.81 / 818.78 | 2 | 2 |
7 | 13 | 1673.72 | 36 | 12.46 | 2658 | 1192 | 5.01 / 819.98 | 2 | 2 |
8 | 13 | 701.96 | 36 | 13.43 | 1325 | 641 | 5.65 / 820.62 | 2 | 3 |
9 | 8 | 0.12 | 180 | 14.35 | 302 | 780 | 6.43 / 821.40 | 2 | 10 |
Average= | 4.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.80 | 31 | 14.13 | 460 | 201 | 0.20 / 808.64 | 2 | 2 |
2 | 12 | 1171.12 | 25 | 6.66 | 1868 | 311 | 0.51 / 808.95 | 2 | 2 |
3 | 12 | 2003.12 | 56 | 5.77 | 2555 | 826 | 1.34 / 809.77 | 2 | 2 |
4 | 12 | 2006.84 | 32 | 5.71 | 2481 | 453 | 1.79 / 810.23 | 2 | 2 |
5 | 7 | 2009.20 | 23 | 10.61 | 3068 | 749 | 2.54 / 810.97 | 2 | 2 |
6 | 13 | 1896.32 | 36 | 11.77 | 2954 | 1252 | 3.79 / 812.23 | 2 | 2 |
7 | 13 | 1678.72 | 36 | 12.29 | 2672 | 1182 | 4.97 / 813.41 | 2 | 2 |
8 | 13 | 932.92 | 36 | 13.17 | 1657 | 786 | 5.76 / 814.19 | 2 | 3 |
9 | 8 | 0.04 | 180 | 14.33 | 301 | 776 | 6.54 / 814.97 | 2 | 8 |
Average= | 4.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.80 | 31 | 14.21 | 453 | 200 | 0.20 / 804.66 | 2 | 2 |
2 | 12 | 1159.48 | 25 | 8.39 | 1846 | 387 | 0.59 / 805.05 | 2 | 2 |
3 | 12 | 1215.64 | 56 | 9.12 | 1969 | 1006 | 1.59 / 806.06 | 2 | 2 |
4 | 12 | 1213.28 | 32 | 8.64 | 1973 | 545 | 2.14 / 806.60 | 2 | 2 |
5 | 7 | 1207.08 | 23 | 11.51 | 2014 | 533 | 2.67 / 807.14 | 2 | 2 |
6 | 13 | 518.08 | 36 | 13.49 | 1067 | 518 | 3.19 / 807.65 | 2 | 3 |
7 | 8 | 0.00 | 180 | 14.26 | 304 | 780 | 3.97 / 808.43 | 2 | 13 |
Average= | 4.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.44 | 31 | 14.23 | 445 | 196 | 0.20 / 798.51 | 2 | 2 |
2 | 12 | 1161.92 | 25 | 8.61 | 1859 | 400 | 0.60 / 798.91 | 2 | 2 |
3 | 12 | 1929.48 | 56 | 5.90 | 2970 | 981 | 1.58 / 799.89 | 2 | 2 |
4 | 12 | 1928.88 | 32 | 5.85 | 3050 | 571 | 2.15 / 800.46 | 2 | 2 |
5 | 7 | 1928.32 | 23 | 11.13 | 2978 | 762 | 2.91 / 801.22 | 2 | 2 |
6 | 13 | 1787.76 | 36 | 12.30 | 2814 | 1246 | 4.16 / 802.47 | 2 | 2 |
7 | 13 | 1149.52 | 36 | 12.99 | 1953 | 913 | 5.07 / 803.38 | 2 | 3 |
8 | 13 | 210.48 | 36 | 14.00 | 620 | 312 | 5.38 / 803.69 | 2 | 3 |
9 | 8 | 0.00 | 180 | 14.34 | 299 | 772 | 6.15 / 804.47 | 2 | 10 |
Average= | 4.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.84 | 30 | 14.17 | 466 | 198 | 0.20 / 792.07 | 2 | 2 |
2 | 12 | 1163.60 | 25 | 8.29 | 1854 | 384 | 0.58 / 792.45 | 2 | 2 |
3 | 12 | 1963.68 | 56 | 5.90 | 2961 | 978 | 1.56 / 793.43 | 2 | 2 |
4 | 12 | 1964.04 | 32 | 5.83 | 3001 | 560 | 2.12 / 793.99 | 2 | 2 |
5 | 7 | 1964.28 | 23 | 11.16 | 3014 | 774 | 2.89 / 794.77 | 2 | 2 |
6 | 13 | 1835.60 | 36 | 12.31 | 2877 | 1275 | 4.17 / 796.04 | 2 | 2 |
7 | 13 | 1389.24 | 36 | 12.78 | 2284 | 1051 | 5.22 / 797.09 | 2 | 2 |
8 | 13 | 391.84 | 36 | 13.79 | 888 | 441 | 5.66 / 797.53 | 2 | 3 |
9 | 8 | 0.00 | 180 | 14.33 | 302 | 779 | 6.44 / 798.31 | 2 | 12 |
Average= | 4.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.36 | 32 | 14.19 | 461 | 209 | 0.21 / 785.41 | 2 | 2 |
2 | 3 | 948.52 | -1 | 14.19 | 461 | 0 | 0.00 / 785.41 | 2 | 2 |
3 | 12 | 1150.28 | 25 | 8.35 | 1843 | 385 | 0.59 / 785.80 | 2 | 2 |
4 | 12 | 1953.08 | 56 | 5.88 | 2903 | 956 | 1.55 / 786.75 | 2 | 2 |
5 | 12 | 1953.04 | 32 | 5.83 | 2953 | 551 | 2.10 / 787.30 | 2 | 2 |
6 | 7 | 1953.08 | 23 | 11.14 | 3003 | 769 | 2.87 / 788.07 | 2 | 2 |
7 | 13 | 1817.52 | 36 | 12.24 | 2849 | 1255 | 4.13 / 789.33 | 2 | 2 |
8 | 13 | 1618.56 | 36 | 12.54 | 2591 | 1170 | 5.30 / 790.50 | 2 | 2 |
9 | 13 | 594.64 | 36 | 13.55 | 1178 | 575 | 5.87 / 791.07 | 2 | 3 |
10 | 8 | 0.20 | 180 | 14.31 | 310 | 798 | 6.67 / 791.87 | 2 | 12 |
Average= | 4.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.08 | 31 | 14.20 | 459 | 202 | 0.20 / 779.52 | 2 | 2 |
2 | 3 | 1027.60 | 1 | 12.27 | 1756 | 22 | 0.22 / 779.54 | 2 | 2 |
3 | 12 | 1172.12 | 25 | 8.75 | 1864 | 408 | 0.63 / 779.95 | 2 | 2 |
4 | 12 | 1979.92 | 56 | 6.24 | 3032 | 1060 | 1.69 / 781.01 | 2 | 2 |
5 | 12 | 1978.20 | 32 | 6.84 | 2948 | 645 | 2.34 / 781.66 | 2 | 2 |
6 | 7 | 1972.92 | 23 | 11.16 | 3059 | 785 | 3.12 / 782.44 | 2 | 2 |
7 | 13 | 1757.60 | 36 | 12.37 | 2769 | 1233 | 4.35 / 783.67 | 2 | 2 |
8 | 13 | 829.60 | 36 | 13.30 | 1521 | 728 | 5.08 / 784.40 | 2 | 3 |
9 | 8 | 0.12 | 180 | 14.33 | 310 | 800 | 5.88 / 785.20 | 2 | 10 |
Average= | 4.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.96 | 31 | 14.23 | 458 | 202 | 0.20 / 772.92 | 2 | 2 |
2 | 12 | 1169.48 | 25 | 8.35 | 1875 | 391 | 0.59 / 773.32 | 2 | 2 |
3 | 12 | 2002.48 | 56 | 5.93 | 3104 | 1031 | 1.62 / 774.35 | 2 | 2 |
4 | 12 | 2002.88 | 32 | 5.90 | 3229 | 610 | 2.23 / 774.96 | 2 | 2 |
5 | 7 | 2002.92 | 23 | 11.21 | 3091 | 797 | 3.03 / 775.75 | 2 | 2 |
6 | 13 | 1853.20 | 36 | 12.35 | 2894 | 1287 | 4.32 / 777.04 | 2 | 2 |
7 | 13 | 1402.60 | 36 | 12.83 | 2288 | 1057 | 5.37 / 778.10 | 2 | 2 |
8 | 13 | 405.88 | 36 | 13.81 | 896 | 445 | 5.82 / 778.54 | 2 | 3 |
9 | 8 | 0.12 | 180 | 14.36 | 301 | 778 | 6.60 / 779.32 | 2 | 13 |
Average= | 4.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.44 | 31 | 14.27 | 445 | 197 | 0.20 / 766.33 | 2 | 2 |
2 | 12 | 1175.20 | 25 | 7.94 | 1858 | 369 | 0.57 / 766.70 | 2 | 2 |
3 | 12 | 2003.28 | 56 | 5.93 | 3042 | 1010 | 1.58 / 767.71 | 2 | 2 |
4 | 12 | 2006.04 | 32 | 5.87 | 3105 | 583 | 2.16 / 768.29 | 2 | 2 |
5 | 7 | 2007.80 | 23 | 11.24 | 3091 | 799 | 2.96 / 769.09 | 2 | 2 |
6 | 13 | 1871.56 | 36 | 12.31 | 2930 | 1298 | 4.26 / 770.39 | 2 | 2 |
7 | 13 | 1447.08 | 36 | 12.76 | 2351 | 1080 | 5.34 / 771.47 | 2 | 2 |
8 | 13 | 470.20 | 36 | 13.74 | 987 | 488 | 5.82 / 771.96 | 2 | 3 |
9 | 8 | -0.12 | 180 | 14.37 | 296 | 766 | 6.59 / 772.72 | 2 | 8 |
Average= | 4.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.00 | 31 | 14.23 | 446 | 197 | 0.20 / 760.22 | 2 | 2 |
2 | 12 | 1179.44 | 25 | 8.26 | 1873 | 387 | 0.58 / 760.60 | 2 | 2 |
3 | 12 | 2001.00 | 56 | 6.14 | 3072 | 1056 | 1.64 / 761.66 | 2 | 2 |
4 | 12 | 2000.68 | 32 | 6.95 | 2988 | 665 | 2.30 / 762.33 | 2 | 2 |
5 | 7 | 1996.24 | 23 | 11.24 | 3096 | 800 | 3.10 / 763.13 | 2 | 2 |
6 | 13 | 1802.92 | 36 | 12.32 | 2836 | 1258 | 4.36 / 764.38 | 2 | 2 |
7 | 13 | 888.48 | 36 | 13.25 | 1595 | 761 | 5.12 / 765.14 | 2 | 3 |
8 | 13 | 81.36 | 36 | 14.22 | 423 | 217 | 5.34 / 765.36 | 2 | 3 |
9 | 8 | 0.00 | 180 | 14.38 | 298 | 771 | 6.11 / 766.13 | 2 | 13 |
Average= | 4.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.16 | 30 | 14.29 | 445 | 191 | 0.19 / 754.57 | 2 | 2 |
2 | 12 | 1162.64 | 25 | 8.41 | 1862 | 391 | 0.58 / 754.96 | 2 | 2 |
3 | 12 | 2004.04 | 56 | 6.80 | 2983 | 1136 | 1.72 / 756.10 | 2 | 2 |
4 | 12 | 2001.96 | 32 | 6.75 | 2982 | 644 | 2.36 / 756.74 | 2 | 2 |
5 | 7 | 1996.56 | 23 | 11.23 | 3089 | 798 | 3.16 / 757.54 | 2 | 2 |
6 | 13 | 1560.72 | 36 | 12.61 | 2508 | 1139 | 4.30 / 758.68 | 2 | 2 |
7 | 13 | 593.08 | 36 | 13.59 | 1164 | 569 | 4.87 / 759.25 | 2 | 3 |
8 | 8 | 0.00 | 180 | 14.36 | 299 | 773 | 5.64 / 760.02 | 2 | 8 |
Average= | 4.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.68 | 32 | 14.27 | 448 | 205 | 0.20 / 748.35 | 2 | 2 |
2 | 3 | 916.32 | -1 | 14.27 | 448 | 0 | 0.00 / 748.35 | 2 | 2 |
3 | 12 | 1147.80 | 25 | 8.27 | 1832 | 379 | 0.58 / 748.72 | 2 | 2 |
4 | 12 | 2004.36 | 56 | 6.00 | 3118 | 1048 | 1.63 / 749.77 | 2 | 2 |
5 | 12 | 2005.48 | 32 | 7.16 | 2990 | 685 | 2.32 / 750.46 | 2 | 2 |
6 | 7 | 2002.12 | 23 | 11.30 | 3104 | 807 | 3.12 / 751.26 | 2 | 2 |
7 | 13 | 1818.80 | 36 | 12.35 | 2857 | 1270 | 4.39 / 752.53 | 2 | 2 |
8 | 13 | 1102.16 | 36 | 13.08 | 1890 | 890 | 5.28 / 753.42 | 2 | 3 |
9 | 13 | 41.12 | 36 | 14.30 | 361 | 186 | 5.47 / 753.61 | 2 | 2 |
10 | 8 | 0.00 | 180 | 14.40 | 297 | 770 | 6.24 / 754.38 | 2 | 14 |
Average= | 4.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.20 | 29 | 14.30 | 449 | 186 | 0.19 / 742.72 | 2 | 2 |
2 | 3 | 1078.84 | 3 | 12.73 | 1818 | 69 | 0.26 / 742.79 | 2 | 2 |
3 | 12 | 1183.72 | 25 | 8.42 | 1892 | 398 | 0.65 / 743.19 | 2 | 2 |
4 | 12 | 2021.56 | 56 | 7.26 | 3029 | 1231 | 1.89 / 744.42 | 2 | 2 |
5 | 12 | 2017.60 | 32 | 7.46 | 3028 | 723 | 2.61 / 745.14 | 2 | 2 |
6 | 7 | 2010.80 | 23 | 11.28 | 3099 | 804 | 3.41 / 745.94 | 2 | 2 |
7 | 13 | 1334.36 | 36 | 12.84 | 2199 | 1016 | 4.43 / 746.96 | 2 | 3 |
8 | 13 | 371.84 | 36 | 13.85 | 847 | 422 | 4.85 / 747.38 | 2 | 3 |
9 | 8 | 0.24 | 180 | 14.38 | 293 | 758 | 5.61 / 748.14 | 2 | 13 |
Average= | 4.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.48 | 31 | 14.31 | 445 | 197 | 0.20 / 736.60 | 2 | 2 |
2 | 3 | 942.52 | -1 | 14.31 | 445 | 0 | 0.00 / 736.60 | 2 | 2 |
3 | 12 | 1167.24 | 16 | 6.08 | 1972 | 192 | 0.39 / 736.80 | 2 | 2 |
4 | 12 | 2003.36 | 50 | 5.92 | 2964 | 877 | 1.27 / 737.67 | 2 | 2 |
5 | 12 | 2007.24 | 32 | 7.06 | 3071 | 694 | 1.96 / 738.37 | 2 | 2 |
6 | 7 | 2006.96 | 23 | 11.42 | 3087 | 811 | 2.77 / 739.18 | 2 | 2 |
7 | 13 | 1847.40 | 36 | 12.44 | 2892 | 1295 | 4.07 / 740.47 | 2 | 2 |
8 | 13 | 1226.04 | 36 | 13.02 | 2066 | 968 | 5.03 / 741.44 | 2 | 3 |
9 | 13 | 235.96 | 36 | 14.06 | 650 | 329 | 5.36 / 741.77 | 2 | 2 |
10 | 8 | 0.12 | 180 | 14.40 | 294 | 762 | 6.13 / 742.53 | 2 | 12 |
Average= | 4.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.20 | 31 | 14.29 | 446 | 198 | 0.20 / 730.52 | 2 | 2 |
2 | 12 | 1153.64 | 16 | 5.79 | 2126 | 197 | 0.39 / 730.71 | 2 | 2 |
3 | 12 | 2017.52 | 50 | 5.94 | 3024 | 898 | 1.29 / 731.61 | 2 | 2 |
4 | 12 | 2021.60 | 32 | 7.69 | 3024 | 744 | 2.04 / 732.36 | 2 | 2 |
5 | 7 | 2020.40 | 23 | 11.43 | 3115 | 819 | 2.86 / 733.18 | 2 | 2 |
6 | 13 | 1828.44 | 36 | 12.45 | 2868 | 1285 | 4.14 / 734.46 | 2 | 2 |
7 | 13 | 1134.96 | 36 | 13.10 | 1929 | 910 | 5.05 / 735.37 | 2 | 3 |
8 | 13 | 155.84 | 36 | 14.15 | 532 | 271 | 5.32 / 735.64 | 2 | 2 |
9 | 8 | -0.08 | 180 | 14.40 | 295 | 765 | 6.09 / 736.41 | 2 | 9 |
Average= | 4.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.52 | 31 | 14.28 | 461 | 204 | 0.20 / 724.65 | 2 | 2 |
2 | 12 | 1170.32 | 13 | 6.95 | 1858 | 168 | 0.37 / 724.81 | 2 | 2 |
3 | 12 | 2003.32 | 50 | 6.78 | 2950 | 1000 | 1.37 / 725.81 | 2 | 2 |
4 | 12 | 2004.28 | 30 | 8.04 | 3011 | 726 | 2.10 / 726.54 | 2 | 2 |
5 | 7 | 1999.20 | 23 | 11.40 | 3085 | 809 | 2.91 / 727.35 | 2 | 2 |
6 | 13 | 1777.64 | 36 | 12.49 | 2799 | 1259 | 4.17 / 728.61 | 2 | 2 |
7 | 13 | 805.00 | 36 | 13.39 | 1478 | 712 | 4.88 / 729.32 | 2 | 3 |
8 | 13 | 56.56 | 36 | 14.26 | 399 | 205 | 5.08 / 729.53 | 2 | 3 |
9 | 8 | -0.08 | 180 | 14.36 | 307 | 794 | 5.88 / 730.32 | 2 | 10 |
Average= | 4.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.28 | 33 | 14.30 | 450 | 212 | 0.21 / 718.68 | 2 | 2 |
2 | 3 | 942.92 | -1 | 14.30 | 450 | 0 | 0.00 / 718.68 | 2 | 2 |
3 | 12 | 1168.84 | 13 | 6.83 | 1852 | 164 | 0.38 / 718.85 | 2 | 2 |
4 | 12 | 2004.12 | 50 | 7.11 | 2975 | 1058 | 1.43 / 719.90 | 2 | 2 |
5 | 12 | 2005.08 | 30 | 8.47 | 3036 | 771 | 2.21 / 720.67 | 2 | 2 |
6 | 7 | 1999.88 | 23 | 11.42 | 3085 | 810 | 3.02 / 721.49 | 2 | 2 |
7 | 13 | 1778.80 | 36 | 12.50 | 2806 | 1263 | 4.28 / 722.75 | 2 | 2 |
8 | 13 | 816.24 | 36 | 13.37 | 1499 | 721 | 5.00 / 723.47 | 2 | 3 |
9 | 13 | 46.28 | 36 | 14.29 | 375 | 193 | 5.19 / 723.66 | 2 | 3 |
10 | 8 | 0.20 | 180 | 14.36 | 302 | 781 | 5.97 / 724.44 | 2 | 9 |
Average= | 4.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.96 | 28 | 14.31 | 457 | 183 | 0.18 / 713.12 | 2 | 2 |
2 | 10 | 1016.80 | 3 | 13.05 | 1740 | 68 | 0.25 / 713.19 | 2 | 2 |
3 | 3 | 1037.44 | 1 | 12.54 | 1776 | 22 | 0.27 / 713.21 | 2 | 2 |
4 | 12 | 1178.48 | 9 | 5.72 | 1896 | 98 | 0.37 / 713.31 | 2 | 2 |
5 | 12 | 2004.96 | 46 | 7.11 | 2859 | 935 | 1.31 / 714.24 | 2 | 2 |
6 | 7 | 2004.44 | 23 | 11.38 | 3071 | 804 | 2.11 / 715.05 | 2 | 2 |
7 | 13 | 1848.92 | 36 | 12.36 | 2900 | 1290 | 3.40 / 716.34 | 2 | 2 |
8 | 13 | 1394.84 | 36 | 12.83 | 2295 | 1060 | 4.46 / 717.40 | 2 | 2 |
9 | 13 | 182.76 | 36 | 14.10 | 576 | 292 | 4.75 / 717.69 | 2 | 3 |
10 | 8 | -0.08 | 180 | 14.35 | 301 | 777 | 5.53 / 718.47 | 2 | 14 |
Average= | 4.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.52 | 35 | 14.30 | 440 | 220 | 0.22 / 707.82 | 2 | 2 |
2 | 3 | 803.64 | -3 | 14.30 | 440 | 0 | 0.00 / 707.82 | 2 | 2 |
3 | 3 | 957.48 | -1 | 14.30 | 440 | 0 | 0.00 / 707.82 | 2 | 2 |
4 | 12 | 1187.24 | 9 | 5.69 | 1758 | 90 | 0.31 / 707.91 | 2 | 2 |
5 | 12 | 2011.24 | 46 | 7.15 | 2804 | 922 | 1.23 / 708.83 | 2 | 2 |
6 | 7 | 2010.60 | 23 | 11.36 | 3082 | 805 | 2.04 / 709.64 | 2 | 2 |
7 | 13 | 1841.96 | 36 | 12.35 | 2877 | 1279 | 3.32 / 710.92 | 2 | 2 |
8 | 13 | 1187.36 | 36 | 12.99 | 2013 | 941 | 4.26 / 711.86 | 2 | 3 |
9 | 13 | 214.92 | 36 | 14.05 | 628 | 318 | 4.58 / 712.18 | 2 | 3 |
10 | 8 | 0.12 | 180 | 14.36 | 295 | 763 | 5.34 / 712.94 | 2 | 12 |
Average= | 4.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.88 | 25 | 14.23 | 468 | 166 | 0.17 / 702.23 | 2 | 2 |
2 | 10 | 1013.60 | 7 | 13.21 | 1737 | 161 | 0.33 / 702.39 | 2 | 2 |
3 | 10 | 1110.96 | 3 | 12.55 | 1898 | 71 | 0.40 / 702.46 | 2 | 2 |
4 | 12 | 1163.44 | 9 | 5.66 | 1627 | 83 | 0.48 / 702.54 | 2 | 2 |
5 | 12 | 2005.00 | 46 | 7.07 | 2697 | 877 | 1.36 / 703.42 | 2 | 2 |
6 | 7 | 2004.04 | 23 | 11.41 | 3070 | 806 | 2.16 / 704.23 | 2 | 2 |
7 | 13 | 1853.68 | 36 | 12.29 | 2901 | 1284 | 3.45 / 705.51 | 2 | 2 |
8 | 13 | 1368.28 | 36 | 12.80 | 2242 | 1033 | 4.48 / 706.54 | 2 | 2 |
9 | 13 | 179.68 | 36 | 14.10 | 570 | 289 | 4.77 / 706.83 | 2 | 2 |
10 | 8 | -0.04 | 180 | 14.35 | 297 | 767 | 5.54 / 707.60 | 2 | 13 |
Average= | 4.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.88 | 38 | 14.27 | 446 | 242 | 0.24 / 699.16 | 2 | 2 |
2 | 3 | 691.68 | -5 | 14.27 | 446 | 0 | 0.00 / 699.16 | 2 | 2 |
3 | 3 | 908.92 | -2 | 14.27 | 446 | 0 | 0.00 / 699.16 | 2 | 2 |
4 | 12 | 1076.92 | 9 | 7.34 | 1835 | 121 | 0.36 / 699.28 | 2 | 2 |
5 | 12 | 1241.88 | 46 | 10.18 | 2017 | 945 | 1.31 / 700.22 | 2 | 2 |
6 | 7 | 1234.72 | 23 | 11.95 | 2065 | 568 | 1.88 / 700.79 | 2 | 2 |
7 | 13 | 472.48 | 36 | 13.61 | 1001 | 490 | 2.37 / 701.28 | 2 | 3 |
8 | 8 | 0.08 | 180 | 14.27 | 304 | 781 | 3.15 / 702.06 | 2 | 10 |
Average= | 4.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.12 | 33 | 14.26 | 457 | 215 | 0.22 / 693.74 | 2 | 2 |
2 | 10 | 1026.72 | 4 | 13.02 | 1771 | 92 | 0.31 / 693.83 | 2 | 2 |
3 | 3 | 1034.36 | 1 | 12.50 | 1763 | 22 | 0.33 / 693.86 | 2 | 2 |
4 | 12 | 1183.92 | 9 | 8.03 | 1885 | 136 | 0.47 / 693.99 | 2 | 2 |
5 | 12 | 2007.60 | 46 | 9.13 | 2962 | 1244 | 1.71 / 695.24 | 2 | 2 |
6 | 7 | 2003.32 | 23 | 11.30 | 3082 | 801 | 2.51 / 696.04 | 2 | 2 |
7 | 13 | 1569.24 | 36 | 12.53 | 2523 | 1138 | 3.65 / 697.18 | 2 | 2 |
8 | 13 | 863.92 | 36 | 13.25 | 1565 | 747 | 4.40 / 697.92 | 2 | 3 |
9 | 13 | 58.92 | 36 | 14.24 | 401 | 206 | 4.60 / 698.13 | 2 | 3 |
10 | 8 | -0.04 | 180 | 14.32 | 306 | 789 | 5.39 / 698.92 | 2 | 10 |
Average= | 4.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.52 | 32 | 14.24 | 460 | 210 | 0.21 / 688.38 | 2 | 2 |
2 | 3 | 1016.60 | 1 | 10.78 | 1764 | 19 | 0.23 / 688.40 | 2 | 2 |
3 | 12 | 1179.44 | 9 | 8.45 | 1897 | 144 | 0.37 / 688.54 | 2 | 2 |
4 | 12 | 2001.24 | 46 | 9.17 | 2980 | 1257 | 1.63 / 689.80 | 2 | 2 |
5 | 7 | 1997.20 | 23 | 11.31 | 3090 | 804 | 2.43 / 690.60 | 2 | 2 |
6 | 13 | 1805.60 | 36 | 12.27 | 2834 | 1252 | 3.69 / 691.85 | 2 | 2 |
7 | 13 | 808.80 | 36 | 13.32 | 1472 | 706 | 4.39 / 692.56 | 2 | 3 |
8 | 13 | 61.28 | 36 | 14.26 | 393 | 202 | 4.59 / 692.76 | 2 | 3 |
9 | 8 | -0.04 | 180 | 14.35 | 297 | 767 | 5.36 / 693.53 | 2 | 11 |
Average= | 4.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.60 | 32 | 14.27 | 454 | 207 | 0.21 / 683.19 | 2 | 2 |
2 | 12 | 1141.96 | 9 | 8.68 | 1832 | 143 | 0.35 / 683.34 | 2 | 2 |
3 | 12 | 2008.84 | 46 | 9.01 | 2955 | 1225 | 1.58 / 684.56 | 2 | 2 |
4 | 7 | 2004.56 | 23 | 11.29 | 3104 | 806 | 2.38 / 685.37 | 2 | 2 |
5 | 13 | 1797.60 | 36 | 12.28 | 2820 | 1247 | 3.63 / 686.61 | 2 | 2 |
6 | 13 | 647.88 | 36 | 13.49 | 1248 | 606 | 4.23 / 687.22 | 2 | 3 |
7 | 13 | 15.60 | 36 | 14.32 | 327 | 169 | 4.40 / 687.39 | 2 | 3 |
8 | 8 | -0.12 | 180 | 14.31 | 302 | 778 | 5.18 / 688.17 | 2 | 11 |
Average= | 4.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.72 | 32 | 14.28 | 433 | 198 | 0.20 / 678.00 | 2 | 2 |
2 | 12 | 1160.24 | 9 | 9.18 | 1854 | 153 | 0.35 / 678.16 | 2 | 2 |
3 | 12 | 2008.40 | 46 | 9.48 | 2993 | 1305 | 1.66 / 679.46 | 2 | 2 |
4 | 7 | 2004.12 | 23 | 11.31 | 3101 | 807 | 2.46 / 680.27 | 2 | 2 |
5 | 13 | 1572.64 | 36 | 12.50 | 2520 | 1134 | 3.60 / 681.40 | 2 | 2 |
6 | 13 | 648.40 | 36 | 13.49 | 1252 | 608 | 4.20 / 682.01 | 2 | 3 |
7 | 13 | 65.12 | 36 | 14.24 | 405 | 208 | 4.41 / 682.22 | 2 | 3 |
8 | 8 | -0.16 | 180 | 14.32 | 298 | 768 | 5.18 / 682.99 | 2 | 13 |
Average= | 4.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.24 | 30 | 14.29 | 440 | 189 | 0.19 / 672.77 | 2 | 2 |
2 | 3 | 1060.72 | 2 | 12.49 | 1801 | 45 | 0.23 / 672.81 | 2 | 2 |
3 | 12 | 1181.44 | 9 | 10.53 | 1939 | 184 | 0.42 / 673.00 | 2 | 2 |
4 | 12 | 2001.52 | 46 | 9.93 | 3001 | 1371 | 1.79 / 674.37 | 2 | 2 |
5 | 7 | 1995.64 | 23 | 11.32 | 3084 | 803 | 2.59 / 675.17 | 2 | 2 |
6 | 13 | 1546.60 | 36 | 12.55 | 2490 | 1125 | 3.72 / 676.29 | 2 | 2 |
7 | 13 | 585.72 | 36 | 13.56 | 1159 | 566 | 4.28 / 676.86 | 2 | 3 |
8 | 13 | 22.60 | 36 | 14.30 | 337 | 173 | 4.46 / 677.03 | 2 | 4 |
9 | 8 | -0.12 | 180 | 14.31 | 300 | 773 | 5.23 / 677.81 | 2 | 17 |
Average= | 4.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.96 | 32 | 14.31 | 438 | 201 | 0.20 / 667.50 | 2 | 2 |
2 | 3 | 952.40 | -1 | 14.31 | 438 | 0 | 0.00 / 667.50 | 2 | 2 |
3 | 12 | 1170.64 | 8 | 10.32 | 1920 | 159 | 0.36 / 667.66 | 2 | 2 |
4 | 12 | 2001.24 | 40 | 9.86 | 2971 | 1172 | 1.53 / 668.83 | 2 | 2 |
5 | 7 | 1996.76 | 23 | 11.34 | 3082 | 804 | 2.33 / 669.64 | 2 | 2 |
6 | 13 | 1776.88 | 36 | 12.29 | 2803 | 1240 | 3.57 / 670.88 | 2 | 2 |
7 | 13 | 831.40 | 36 | 13.27 | 1513 | 723 | 4.30 / 671.60 | 2 | 3 |
8 | 13 | 47.88 | 36 | 14.25 | 385 | 198 | 4.50 / 671.80 | 2 | 3 |
9 | 8 | -0.28 | 180 | 14.30 | 303 | 780 | 5.28 / 672.58 | 2 | 13 |
Average= | 4.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.80 | 32 | 14.26 | 441 | 201 | 0.20 / 662.24 | 2 | 2 |
2 | 12 | 1154.28 | 8 | 10.36 | 1869 | 155 | 0.36 / 662.39 | 2 | 2 |
3 | 12 | 2001.20 | 40 | 9.73 | 3006 | 1170 | 1.53 / 663.56 | 2 | 2 |
4 | 7 | 1997.12 | 23 | 11.34 | 3081 | 804 | 2.33 / 664.37 | 2 | 2 |
5 | 13 | 1779.80 | 36 | 12.29 | 2818 | 1247 | 3.58 / 665.61 | 2 | 2 |
6 | 13 | 802.72 | 36 | 13.30 | 1471 | 704 | 4.28 / 666.32 | 2 | 3 |
7 | 13 | 53.52 | 36 | 14.24 | 393 | 201 | 4.48 / 666.52 | 2 | 3 |
8 | 8 | 0.04 | 180 | 14.30 | 304 | 782 | 5.26 / 667.30 | 2 | 10 |
Average= | 4.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.44 | 32 | 14.25 | 447 | 204 | 0.20 / 657.22 | 2 | 2 |
2 | 12 | 1150.00 | 8 | 10.65 | 1888 | 161 | 0.36 / 657.38 | 2 | 2 |
3 | 12 | 2003.20 | 40 | 9.77 | 2999 | 1172 | 1.54 / 658.55 | 2 | 2 |
4 | 7 | 1997.80 | 23 | 11.34 | 3089 | 806 | 2.34 / 659.36 | 2 | 2 |
5 | 13 | 1562.28 | 36 | 12.52 | 2504 | 1129 | 3.47 / 660.49 | 2 | 2 |
6 | 13 | 639.56 | 36 | 13.48 | 1238 | 601 | 4.07 / 661.09 | 2 | 3 |
7 | 13 | 13.24 | 36 | 14.31 | 328 | 169 | 4.24 / 661.26 | 2 | 4 |
8 | 8 | -0.12 | 180 | 14.27 | 304 | 781 | 5.02 / 662.04 | 2 | 10 |
Average= | 4.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.92 | 33 | 14.26 | 458 | 216 | 0.22 / 652.01 | 2 | 2 |
2 | 3 | 956.56 | -1 | 14.26 | 458 | 0 | 0.00 / 652.01 | 2 | 2 |
3 | 12 | 1171.44 | 8 | 11.39 | 1927 | 176 | 0.39 / 652.18 | 2 | 2 |
4 | 12 | 2002.60 | 40 | 10.21 | 3021 | 1234 | 1.62 / 653.42 | 2 | 2 |
5 | 7 | 1997.12 | 23 | 11.35 | 3084 | 805 | 2.43 / 654.22 | 2 | 2 |
6 | 13 | 1556.00 | 36 | 12.51 | 2497 | 1125 | 3.55 / 655.35 | 2 | 2 |
7 | 13 | 813.16 | 36 | 13.27 | 1493 | 713 | 4.27 / 656.06 | 2 | 3 |
8 | 13 | 16.80 | 36 | 14.30 | 336 | 173 | 4.44 / 656.23 | 2 | 4 |
9 | 8 | -0.12 | 180 | 14.26 | 305 | 783 | 5.22 / 657.02 | 2 | 11 |
Average= | 4.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.92 | 31 | 14.28 | 465 | 206 | 0.21 / 646.63 | 2 | 2 |
2 | 3 | 1066.24 | 2 | 12.52 | 1822 | 46 | 0.25 / 646.68 | 2 | 2 |
3 | 12 | 1166.80 | 8 | 11.20 | 1923 | 172 | 0.42 / 646.85 | 2 | 2 |
4 | 12 | 2002.04 | 40 | 10.03 | 3015 | 1210 | 1.63 / 648.06 | 2 | 2 |
5 | 7 | 1997.24 | 23 | 11.36 | 3091 | 808 | 2.44 / 648.87 | 2 | 2 |
6 | 13 | 1789.40 | 36 | 12.28 | 2814 | 1244 | 3.69 / 650.11 | 2 | 2 |
7 | 13 | 800.40 | 36 | 13.29 | 1478 | 707 | 4.39 / 650.82 | 2 | 3 |
8 | 13 | 44.48 | 36 | 14.25 | 379 | 194 | 4.59 / 651.01 | 2 | 3 |
9 | 8 | -0.16 | 180 | 14.28 | 303 | 779 | 5.37 / 651.79 | 2 | 15 |
Average= | 4.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.40 | 32 | 14.25 | 456 | 208 | 0.21 / 641.57 | 2 | 2 |
2 | 3 | 967.08 | -1 | 14.25 | 456 | 0 | 0.00 / 641.57 | 2 | 2 |
3 | 3 | 1028.32 | 1 | 11.96 | 1756 | 21 | 0.23 / 641.59 | 2 | 2 |
4 | 12 | 1170.60 | 8 | 11.44 | 1941 | 178 | 0.41 / 641.76 | 2 | 2 |
5 | 12 | 2003.24 | 40 | 10.07 | 3015 | 1214 | 1.62 / 642.98 | 2 | 2 |
6 | 7 | 1998.44 | 23 | 11.36 | 3097 | 809 | 2.43 / 643.79 | 2 | 2 |
7 | 13 | 1547.44 | 36 | 12.51 | 2490 | 1121 | 3.55 / 644.91 | 2 | 2 |
8 | 13 | 829.28 | 36 | 13.26 | 1520 | 726 | 4.28 / 645.64 | 2 | 3 |
9 | 8 | -0.08 | 180 | 14.28 | 308 | 792 | 5.07 / 646.43 | 2 | 13 |
Average= | 4.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.80 | 32 | 14.25 | 449 | 205 | 0.20 / 636.37 | 2 | 2 |
2 | 12 | 1152.40 | 8 | 11.52 | 1908 | 176 | 0.38 / 636.54 | 2 | 2 |
3 | 12 | 2003.32 | 40 | 10.01 | 3007 | 1204 | 1.58 / 637.75 | 2 | 2 |
4 | 7 | 1998.60 | 23 | 11.34 | 3095 | 807 | 2.39 / 638.56 | 2 | 2 |
5 | 13 | 1550.56 | 36 | 12.50 | 2499 | 1125 | 3.52 / 639.68 | 2 | 2 |
6 | 13 | 824.56 | 36 | 13.26 | 1502 | 717 | 4.23 / 640.40 | 2 | 3 |
7 | 13 | 25.12 | 36 | 14.29 | 345 | 177 | 4.41 / 640.57 | 2 | 3 |
8 | 8 | 0.20 | 180 | 14.28 | 305 | 784 | 5.19 / 641.36 | 2 | 12 |
Average= | 4.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.44 | 32 | 14.25 | 447 | 204 | 0.20 / 631.34 | 2 | 2 |
2 | 12 | 1148.08 | 8 | 11.68 | 1891 | 177 | 0.38 / 631.51 | 2 | 2 |
3 | 12 | 2010.36 | 40 | 10.06 | 3033 | 1220 | 1.60 / 632.73 | 2 | 2 |
4 | 7 | 2004.84 | 23 | 11.32 | 3094 | 806 | 2.41 / 633.54 | 2 | 2 |
5 | 13 | 1560.24 | 36 | 12.48 | 2501 | 1124 | 3.53 / 634.66 | 2 | 2 |
6 | 13 | 828.52 | 36 | 13.26 | 1505 | 718 | 4.25 / 635.38 | 2 | 3 |
7 | 8 | -0.24 | 180 | 14.28 | 304 | 781 | 5.03 / 636.16 | 2 | 8 |
Average= | 4.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.20 | 31 | 14.24 | 456 | 201 | 0.20 / 626.61 | 2 | 2 |
2 | 3 | 1015.84 | 1 | 9.44 | 1749 | 17 | 0.22 / 626.63 | 2 | 2 |
3 | 12 | 1166.88 | 8 | 11.70 | 1928 | 180 | 0.40 / 626.81 | 2 | 2 |
4 | 12 | 2000.24 | 40 | 10.37 | 3053 | 1266 | 1.66 / 628.07 | 2 | 2 |
5 | 7 | 1994.48 | 23 | 11.25 | 3078 | 796 | 2.46 / 628.87 | 2 | 2 |
6 | 13 | 1352.52 | 36 | 12.66 | 2232 | 1017 | 3.48 / 629.89 | 2 | 2 |
7 | 13 | 428.20 | 36 | 13.72 | 939 | 464 | 3.94 / 630.35 | 2 | 3 |
8 | 8 | -0.04 | 180 | 14.27 | 305 | 783 | 4.73 / 631.13 | 2 | 14 |
Average= | 4.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.76 | 32 | 14.23 | 461 | 210 | 0.21 / 621.66 | 2 | 2 |
2 | 3 | 960.84 | -1 | 14.23 | 461 | 0 | 0.00 / 621.66 | 2 | 2 |
3 | 3 | 1021.88 | 1 | 11.30 | 1760 | 20 | 0.23 / 621.68 | 2 | 2 |
4 | 12 | 1158.92 | 8 | 11.73 | 1917 | 180 | 0.41 / 621.86 | 2 | 2 |
5 | 12 | 2000.16 | 40 | 10.38 | 3056 | 1269 | 1.68 / 623.13 | 2 | 2 |
6 | 7 | 1994.48 | 23 | 11.29 | 3093 | 803 | 2.48 / 623.93 | 2 | 2 |
7 | 13 | 1555.92 | 36 | 12.47 | 2493 | 1119 | 3.60 / 625.05 | 2 | 2 |
8 | 13 | 588.68 | 36 | 13.53 | 1168 | 569 | 4.17 / 625.62 | 2 | 3 |
9 | 8 | 0.04 | 180 | 14.27 | 308 | 791 | 4.96 / 626.41 | 2 | 14 |
Average= | 4.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.76 | 30 | 14.25 | 459 | 196 | 0.20 / 616.52 | 2 | 2 |
2 | 3 | 1033.24 | 1 | 12.41 | 1754 | 22 | 0.22 / 616.54 | 2 | 2 |
3 | 3 | 1018.00 | 1 | 12.07 | 1776 | 21 | 0.24 / 616.56 | 2 | 2 |
4 | 12 | 1174.16 | 8 | 11.73 | 1945 | 183 | 0.42 / 616.74 | 2 | 2 |
5 | 12 | 2017.00 | 40 | 10.35 | 3075 | 1273 | 1.69 / 618.01 | 2 | 2 |
6 | 7 | 2012.44 | 23 | 11.28 | 3119 | 809 | 2.50 / 618.82 | 2 | 2 |
7 | 13 | 1558.84 | 36 | 12.46 | 2504 | 1123 | 3.63 / 619.95 | 2 | 2 |
8 | 13 | 807.44 | 36 | 13.27 | 1480 | 707 | 4.33 / 620.65 | 2 | 3 |
9 | 8 | 0.00 | 180 | 14.26 | 309 | 793 | 5.13 / 621.45 | 2 | 16 |
Average= | 4.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.44 | 31 | 14.22 | 461 | 203 | 0.20 / 611.59 | 2 | 2 |
2 | 3 | 969.64 | -1 | 14.22 | 461 | 0 | 0.00 / 611.59 | 2 | 2 |
3 | 3 | 1028.72 | 1 | 12.13 | 1760 | 21 | 0.22 / 611.61 | 2 | 2 |
4 | 12 | 1183.60 | 8 | 11.75 | 1937 | 182 | 0.41 / 611.79 | 2 | 2 |
5 | 12 | 2002.48 | 40 | 10.37 | 3075 | 1276 | 1.68 / 613.06 | 2 | 2 |
6 | 7 | 1996.96 | 23 | 11.27 | 3097 | 803 | 2.48 / 613.87 | 2 | 2 |
7 | 13 | 1536.00 | 36 | 12.46 | 2476 | 1111 | 3.60 / 614.98 | 2 | 2 |
8 | 13 | 559.84 | 36 | 13.56 | 1127 | 550 | 4.15 / 615.53 | 2 | 3 |
9 | 8 | 0.00 | 180 | 14.27 | 308 | 791 | 4.94 / 616.32 | 2 | 15 |
Average= | 4.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.48 | 31 | 14.20 | 464 | 204 | 0.20 / 606.64 | 2 | 2 |
2 | 12 | 1173.72 | 8 | 11.70 | 1932 | 181 | 0.39 / 606.82 | 2 | 2 |
3 | 12 | 2000.16 | 40 | 10.38 | 3069 | 1274 | 1.66 / 608.10 | 2 | 2 |
4 | 7 | 1994.48 | 23 | 11.25 | 3086 | 799 | 2.46 / 608.89 | 2 | 2 |
5 | 13 | 1563.16 | 36 | 12.45 | 2495 | 1118 | 3.58 / 610.01 | 2 | 2 |
6 | 13 | 613.20 | 36 | 13.50 | 1203 | 585 | 4.16 / 610.60 | 2 | 3 |
7 | 8 | -0.08 | 180 | 14.26 | 306 | 785 | 4.95 / 611.38 | 2 | 9 |
Average= | 4.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.00 | 30 | 14.21 | 462 | 197 | 0.20 / 601.69 | 2 | 2 |
2 | 3 | 1015.96 | 1 | 9.77 | 1741 | 17 | 0.21 / 601.70 | 2 | 2 |
3 | 3 | 1019.20 | 1 | 11.10 | 1771 | 20 | 0.23 / 601.72 | 2 | 2 |
4 | 12 | 1174.12 | 8 | 11.70 | 1915 | 179 | 0.41 / 601.90 | 2 | 2 |
5 | 12 | 1999.48 | 40 | 10.41 | 3070 | 1278 | 1.69 / 603.18 | 2 | 2 |
6 | 7 | 1994.12 | 23 | 11.28 | 3086 | 801 | 2.49 / 603.98 | 2 | 2 |
7 | 13 | 1520.24 | 36 | 12.49 | 2466 | 1109 | 3.60 / 605.09 | 2 | 2 |
8 | 13 | 556.52 | 36 | 13.57 | 1124 | 549 | 4.15 / 605.64 | 2 | 3 |
9 | 8 | 0.08 | 180 | 14.25 | 311 | 798 | 4.95 / 606.44 | 2 | 13 |
Average= | 4.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.64 | 32 | 14.26 | 457 | 209 | 0.21 / 596.72 | 2 | 2 |
2 | 3 | 956.88 | -1 | 14.26 | 457 | 0 | 0.00 / 596.72 | 2 | 2 |
3 | 12 | 1166.12 | 8 | 11.77 | 1928 | 182 | 0.39 / 596.91 | 2 | 2 |
4 | 12 | 2001.08 | 40 | 10.47 | 3072 | 1287 | 1.68 / 598.19 | 2 | 2 |
5 | 7 | 1995.68 | 23 | 11.28 | 3077 | 798 | 2.47 / 598.99 | 2 | 2 |
6 | 13 | 1555.44 | 36 | 12.48 | 2500 | 1123 | 3.60 / 600.11 | 2 | 2 |
7 | 13 | 592.72 | 36 | 13.52 | 1179 | 574 | 4.17 / 600.69 | 2 | 3 |
8 | 8 | 0.08 | 180 | 14.26 | 312 | 801 | 4.97 / 601.49 | 2 | 13 |
Average= | 4.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.00 | 31 | 14.25 | 473 | 209 | 0.21 / 591.76 | 2 | 2 |
2 | 3 | 1030.20 | 1 | 12.33 | 1774 | 22 | 0.23 / 591.78 | 2 | 2 |
3 | 12 | 1172.60 | 8 | 11.79 | 1927 | 182 | 0.41 / 591.96 | 2 | 2 |
4 | 12 | 1999.72 | 40 | 10.49 | 3056 | 1282 | 1.69 / 593.25 | 2 | 2 |
5 | 7 | 1993.96 | 23 | 11.28 | 3098 | 804 | 2.50 / 594.05 | 2 | 2 |
6 | 13 | 1534.96 | 36 | 12.50 | 2464 | 1109 | 3.61 / 595.16 | 2 | 2 |
7 | 13 | 570.88 | 36 | 13.56 | 1144 | 558 | 4.17 / 595.72 | 2 | 3 |
8 | 8 | 0.00 | 180 | 14.26 | 311 | 798 | 4.96 / 596.52 | 2 | 10 |
Average= | 4.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.84 | 31 | 14.26 | 458 | 202 | 0.20 / 586.67 | 2 | 2 |
2 | 12 | 1168.88 | 8 | 11.71 | 1919 | 180 | 0.38 / 586.85 | 2 | 2 |
3 | 12 | 2008.44 | 40 | 10.41 | 3080 | 1283 | 1.66 / 588.14 | 2 | 2 |
4 | 7 | 2003.16 | 23 | 11.27 | 3114 | 807 | 2.47 / 588.94 | 2 | 2 |
5 | 13 | 1539.28 | 36 | 12.46 | 2475 | 1110 | 3.58 / 590.05 | 2 | 2 |
6 | 13 | 793.16 | 36 | 13.28 | 1461 | 698 | 4.28 / 590.75 | 2 | 3 |
7 | 8 | 0.00 | 180 | 14.25 | 312 | 800 | 5.08 / 591.55 | 2 | 10 |
Average= | 4.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.08 | 31 | 14.23 | 458 | 202 | 0.20 / 581.59 | 2 | 2 |
2 | 12 | 1163.80 | 8 | 11.67 | 1920 | 179 | 0.38 / 581.77 | 2 | 2 |
3 | 12 | 2005.96 | 40 | 10.43 | 3068 | 1280 | 1.66 / 583.05 | 2 | 2 |
4 | 7 | 2000.32 | 23 | 11.26 | 3087 | 799 | 2.46 / 583.85 | 2 | 2 |
5 | 13 | 1542.60 | 36 | 12.46 | 2476 | 1111 | 3.57 / 584.96 | 2 | 2 |
6 | 13 | 577.64 | 36 | 13.54 | 1153 | 562 | 4.13 / 585.52 | 2 | 3 |
7 | 13 | 2.44 | 36 | 14.33 | 316 | 163 | 4.30 / 585.68 | 2 | 5 |
8 | 8 | 0.00 | 180 | 14.24 | 307 | 787 | 5.08 / 586.47 | 2 | 16 |
Average= | 4.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.44 | 30 | 14.24 | 457 | 195 | 0.20 / 576.85 | 2 | 2 |
2 | 12 | 1168.04 | 8 | 11.77 | 1934 | 182 | 0.38 / 577.04 | 2 | 2 |
3 | 12 | 1998.84 | 40 | 10.49 | 3087 | 1295 | 1.67 / 578.33 | 2 | 2 |
4 | 7 | 1993.20 | 23 | 11.23 | 3085 | 797 | 2.47 / 579.13 | 2 | 2 |
5 | 13 | 1340.28 | 36 | 12.66 | 2229 | 1016 | 3.49 / 580.14 | 2 | 2 |
6 | 13 | 407.20 | 36 | 13.75 | 915 | 453 | 3.94 / 580.60 | 2 | 3 |
7 | 8 | 0.08 | 180 | 14.26 | 308 | 791 | 4.73 / 581.39 | 2 | 14 |
Average= | 4.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.68 | 31 | 14.22 | 458 | 202 | 0.20 / 571.88 | 2 | 2 |
2 | 3 | 965.36 | -1 | 14.22 | 458 | 0 | 0.00 / 571.88 | 2 | 2 |
3 | 3 | 1028.44 | 1 | 12.09 | 1771 | 21 | 0.22 / 571.91 | 2 | 2 |
4 | 12 | 1181.72 | 8 | 11.75 | 1938 | 182 | 0.41 / 572.09 | 2 | 2 |
5 | 12 | 2000.48 | 40 | 10.70 | 3065 | 1312 | 1.72 / 573.40 | 2 | 2 |
6 | 7 | 1995.32 | 23 | 11.24 | 3090 | 799 | 2.52 / 574.20 | 2 | 2 |
7 | 13 | 1545.08 | 36 | 12.46 | 2489 | 1116 | 3.63 / 575.31 | 2 | 2 |
8 | 13 | 549.84 | 36 | 13.57 | 1119 | 547 | 4.18 / 575.86 | 2 | 3 |
9 | 8 | -0.08 | 180 | 14.25 | 311 | 798 | 4.98 / 576.66 | 2 | 12 |
Average= | 4.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.36 | 31 | 14.23 | 462 | 204 | 0.20 / 566.94 | 2 | 2 |
2 | 12 | 1154.72 | 8 | 11.83 | 1900 | 180 | 0.38 / 567.12 | 2 | 2 |
3 | 12 | 2014.36 | 40 | 10.39 | 3078 | 1279 | 1.66 / 568.40 | 2 | 2 |
4 | 7 | 2009.28 | 23 | 11.28 | 3104 | 805 | 2.47 / 569.20 | 2 | 2 |
5 | 13 | 1556.88 | 36 | 12.47 | 2491 | 1118 | 3.59 / 570.32 | 2 | 2 |
6 | 13 | 589.60 | 36 | 13.56 | 1164 | 568 | 4.15 / 570.89 | 2 | 3 |
7 | 8 | 0.00 | 180 | 14.27 | 308 | 791 | 4.95 / 571.68 | 2 | 11 |
Average= | 4.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.20 | 32 | 14.23 | 467 | 213 | 0.21 / 561.82 | 2 | 2 |
2 | 3 | 968.64 | -1 | 14.23 | 467 | 0 | 0.00 / 561.82 | 2 | 2 |
3 | 3 | 1037.88 | 1 | 12.25 | 1768 | 22 | 0.23 / 561.84 | 2 | 2 |
4 | 12 | 1164.76 | 8 | 11.80 | 1925 | 182 | 0.42 / 562.02 | 2 | 2 |
5 | 12 | 2009.60 | 40 | 10.43 | 3084 | 1287 | 1.70 / 563.31 | 2 | 2 |
6 | 7 | 2003.64 | 23 | 11.26 | 3103 | 804 | 2.51 / 564.11 | 2 | 2 |
7 | 13 | 1542.52 | 36 | 12.48 | 2498 | 1122 | 3.63 / 565.24 | 2 | 2 |
8 | 13 | 802.16 | 36 | 13.30 | 1472 | 705 | 4.33 / 565.94 | 2 | 3 |
9 | 8 | 0.16 | 180 | 14.26 | 310 | 796 | 5.13 / 566.74 | 2 | 12 |
Average= | 4.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.28 | 31 | 14.26 | 463 | 205 | 0.20 / 556.71 | 2 | 2 |
2 | 12 | 1169.76 | 8 | 11.75 | 1921 | 181 | 0.39 / 556.89 | 2 | 2 |
3 | 12 | 2001.88 | 40 | 10.48 | 3076 | 1289 | 1.67 / 558.18 | 2 | 2 |
4 | 7 | 1996.04 | 23 | 11.25 | 3089 | 799 | 2.47 / 558.98 | 2 | 2 |
5 | 13 | 1538.76 | 36 | 12.48 | 2482 | 1115 | 3.59 / 560.09 | 2 | 2 |
6 | 13 | 582.24 | 36 | 13.57 | 1161 | 567 | 4.16 / 560.66 | 2 | 3 |
7 | 13 | 3.44 | 36 | 14.35 | 315 | 163 | 4.32 / 560.82 | 2 | 5 |
8 | 8 | -0.12 | 180 | 14.26 | 305 | 783 | 5.10 / 561.61 | 2 | 12 |
Average= | 4.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.72 | 31 | 14.27 | 456 | 202 | 0.20 / 551.76 | 2 | 2 |
2 | 12 | 1154.44 | 8 | 11.88 | 1898 | 180 | 0.38 / 551.94 | 2 | 2 |
3 | 12 | 2005.08 | 40 | 10.47 | 3079 | 1289 | 1.67 / 553.23 | 2 | 2 |
4 | 7 | 1999.72 | 23 | 11.26 | 3099 | 803 | 2.47 / 554.04 | 2 | 2 |
5 | 13 | 1541.52 | 36 | 12.51 | 2469 | 1112 | 3.59 / 555.15 | 2 | 2 |
6 | 13 | 594.52 | 36 | 13.56 | 1171 | 572 | 4.16 / 555.72 | 2 | 3 |
7 | 8 | -0.08 | 180 | 14.26 | 306 | 785 | 4.94 / 556.51 | 2 | 4 |
Average= | 4.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.36 | 32 | 14.24 | 458 | 209 | 0.21 / 546.80 | 2 | 2 |
2 | 3 | 967.08 | -1 | 14.24 | 458 | 0 | 0.00 / 546.80 | 2 | 2 |
3 | 12 | 1171.68 | 8 | 11.73 | 1931 | 181 | 0.39 / 546.98 | 2 | 2 |
4 | 12 | 2000.88 | 40 | 10.54 | 3077 | 1297 | 1.69 / 548.28 | 2 | 2 |
5 | 7 | 1995.80 | 23 | 11.28 | 3105 | 806 | 2.49 / 549.09 | 2 | 2 |
6 | 13 | 1550.04 | 36 | 12.48 | 2483 | 1116 | 3.61 / 550.20 | 2 | 2 |
7 | 13 | 582.12 | 36 | 13.56 | 1159 | 566 | 4.17 / 550.77 | 2 | 3 |
8 | 8 | -0.04 | 180 | 14.26 | 310 | 796 | 4.97 / 551.56 | 2 | 9 |
Average= | 4.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.52 | 32 | 14.27 | 468 | 214 | 0.21 / 541.80 | 2 | 2 |
2 | 12 | 1165.00 | 8 | 11.75 | 1922 | 181 | 0.39 / 541.98 | 2 | 2 |
3 | 12 | 2000.96 | 40 | 10.57 | 3098 | 1310 | 1.70 / 543.29 | 2 | 2 |
4 | 7 | 1995.64 | 23 | 11.28 | 3085 | 800 | 2.50 / 544.09 | 2 | 2 |
5 | 13 | 1558.28 | 36 | 12.46 | 2517 | 1129 | 3.63 / 545.22 | 2 | 2 |
6 | 13 | 592.28 | 36 | 13.54 | 1177 | 574 | 4.21 / 545.79 | 2 | 3 |
7 | 8 | 0.08 | 180 | 14.26 | 311 | 798 | 5.01 / 546.59 | 2 | 15 |
Average= | 4.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.16 | 32 | 14.26 | 459 | 209 | 0.21 / 536.71 | 2 | 2 |
2 | 3 | 950.88 | -1 | 14.26 | 459 | 0 | 0.00 / 536.71 | 2 | 2 |
3 | 3 | 1021.12 | 1 | 9.72 | 1724 | 17 | 0.23 / 536.73 | 2 | 2 |
4 | 12 | 1135.52 | 8 | 11.82 | 1880 | 178 | 0.40 / 536.90 | 2 | 2 |
5 | 12 | 1984.68 | 40 | 10.61 | 3045 | 1292 | 1.70 / 538.20 | 2 | 2 |
6 | 7 | 1979.48 | 23 | 11.25 | 3071 | 795 | 2.49 / 538.99 | 2 | 2 |
7 | 13 | 1505.84 | 36 | 12.52 | 2440 | 1100 | 3.59 / 540.09 | 2 | 2 |
8 | 13 | 527.88 | 36 | 13.63 | 1088 | 534 | 4.12 / 540.63 | 2 | 3 |
9 | 13 | 16.96 | 36 | 14.30 | 340 | 175 | 4.30 / 540.80 | 2 | 4 |
10 | 8 | -0.12 | 180 | 14.23 | 307 | 786 | 5.09 / 541.59 | 2 | 17 |
Average= | 4.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.00 | 32 | 14.29 | 456 | 209 | 0.21 / 531.83 | 2 | 2 |
2 | 12 | 1100.52 | 8 | 11.78 | 1841 | 173 | 0.38 / 532.00 | 2 | 2 |
3 | 12 | 1988.48 | 40 | 10.46 | 3048 | 1275 | 1.66 / 533.28 | 2 | 2 |
4 | 7 | 1981.84 | 23 | 11.30 | 3075 | 799 | 2.46 / 534.08 | 2 | 2 |
5 | 13 | 1503.20 | 36 | 12.53 | 2426 | 1094 | 3.55 / 535.17 | 2 | 2 |
6 | 13 | 549.84 | 36 | 13.61 | 1108 | 543 | 4.09 / 535.72 | 2 | 3 |
7 | 8 | -0.08 | 180 | 14.26 | 306 | 785 | 4.88 / 536.50 | 2 | 12 |
Average= | 4.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.32 | 32 | 14.28 | 459 | 210 | 0.21 / 527.11 | 2 | 2 |
2 | 12 | 1101.28 | 8 | 11.82 | 1829 | 173 | 0.38 / 527.28 | 2 | 2 |
3 | 12 | 2001.28 | 40 | 10.40 | 3066 | 1275 | 1.66 / 528.56 | 2 | 2 |
4 | 7 | 1996.24 | 23 | 11.28 | 3087 | 801 | 2.46 / 529.36 | 2 | 2 |
5 | 13 | 1349.40 | 36 | 12.68 | 2222 | 1014 | 3.47 / 530.37 | 2 | 3 |
6 | 13 | 420.84 | 36 | 13.78 | 933 | 463 | 3.94 / 530.84 | 2 | 3 |
7 | 8 | 0.12 | 180 | 14.28 | 305 | 784 | 4.72 / 531.62 | 2 | 9 |
Average= | 4.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.80 | 32 | 14.33 | 453 | 208 | 0.21 / 521.96 | 2 | 2 |
2 | 12 | 1129.32 | 8 | 11.79 | 1867 | 176 | 0.38 / 522.14 | 2 | 2 |
3 | 12 | 2003.48 | 41 | 10.49 | 3079 | 1324 | 1.71 / 523.46 | 2 | 2 |
4 | 7 | 1998.28 | 23 | 11.28 | 3087 | 801 | 2.51 / 524.27 | 2 | 2 |
5 | 13 | 1360.28 | 34 | 12.71 | 2249 | 972 | 3.48 / 525.24 | 2 | 2 |
6 | 13 | 648.40 | 34 | 13.52 | 1249 | 574 | 4.05 / 525.81 | 2 | 3 |
7 | 13 | 12.96 | 34 | 14.33 | 334 | 163 | 4.22 / 525.97 | 2 | 4 |
8 | 13 | 2.92 | 34 | 14.30 | 313 | 152 | 4.37 / 526.13 | 2 | 4 |
9 | 8 | -0.32 | 180 | 14.26 | 302 | 775 | 5.15 / 526.90 | 2 | 15 |
Average= | 4.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.00 | 32 | 14.32 | 448 | 205 | 0.21 / 516.95 | 2 | 2 |
2 | 12 | 1099.24 | 8 | 11.92 | 1815 | 173 | 0.38 / 517.12 | 2 | 2 |
3 | 12 | 2010.00 | 41 | 10.42 | 3082 | 1317 | 1.70 / 518.44 | 2 | 2 |
4 | 7 | 2004.68 | 23 | 11.32 | 3097 | 806 | 2.50 / 519.25 | 2 | 2 |
5 | 13 | 1370.00 | 34 | 12.71 | 2251 | 973 | 3.47 / 520.22 | 2 | 2 |
6 | 13 | 669.72 | 34 | 13.49 | 1283 | 588 | 4.06 / 520.81 | 2 | 3 |
7 | 13 | 8.08 | 34 | 14.33 | 327 | 159 | 4.22 / 520.97 | 2 | 3 |
8 | 8 | -0.24 | 180 | 14.24 | 308 | 789 | 5.01 / 521.76 | 2 | 14 |
Average= | 4.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.48 | 31 | 14.28 | 455 | 201 | 0.20 / 511.91 | 2 | 2 |
2 | 3 | 1023.44 | 1 | 10.79 | 1748 | 19 | 0.22 / 511.92 | 2 | 2 |
3 | 3 | 1018.60 | 1 | 10.39 | 1714 | 18 | 0.24 / 511.94 | 2 | 2 |
4 | 12 | 1158.52 | 8 | 11.91 | 1904 | 181 | 0.42 / 512.12 | 2 | 2 |
5 | 12 | 2002.88 | 41 | 10.66 | 3072 | 1343 | 1.76 / 513.47 | 2 | 2 |
6 | 7 | 1997.80 | 23 | 11.35 | 3094 | 808 | 2.57 / 514.27 | 2 | 2 |
7 | 13 | 1544.08 | 32 | 12.58 | 2501 | 1007 | 3.58 / 515.28 | 2 | 2 |
8 | 13 | 597.08 | 32 | 13.61 | 1173 | 511 | 4.09 / 515.79 | 2 | 3 |
9 | 13 | 33.72 | 32 | 14.29 | 367 | 168 | 4.26 / 515.96 | 2 | 3 |
10 | 8 | -0.16 | 180 | 14.27 | 306 | 786 | 5.04 / 516.75 | 2 | 12 |
Average= | 4.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.88 | 32 | 14.34 | 445 | 204 | 0.20 / 506.92 | 2 | 2 |
2 | 3 | 957.08 | -1 | 14.34 | 445 | 0 | 0.00 / 506.92 | 2 | 2 |
3 | 12 | 1135.72 | 8 | 11.89 | 1852 | 176 | 0.38 / 507.09 | 2 | 2 |
4 | 12 | 2010.04 | 41 | 10.59 | 3093 | 1343 | 1.72 / 508.44 | 2 | 2 |
5 | 7 | 2005.04 | 23 | 11.35 | 3111 | 812 | 2.54 / 509.25 | 2 | 2 |
6 | 13 | 1525.72 | 32 | 12.63 | 2462 | 995 | 3.53 / 510.24 | 2 | 2 |
7 | 13 | 590.64 | 32 | 13.63 | 1166 | 509 | 4.04 / 510.75 | 2 | 3 |
8 | 13 | 23.80 | 32 | 14.31 | 351 | 161 | 4.20 / 510.91 | 2 | 3 |
9 | 8 | -0.16 | 180 | 14.26 | 308 | 791 | 4.99 / 511.70 | 2 | 10 |
Average= | 4.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.84 | 32 | 14.32 | 455 | 208 | 0.21 / 501.99 | 2 | 2 |
2 | 12 | 1145.88 | 8 | 11.95 | 1879 | 180 | 0.39 / 502.17 | 2 | 2 |
3 | 12 | 2005.88 | 41 | 10.65 | 3102 | 1354 | 1.74 / 503.52 | 2 | 2 |
4 | 7 | 2000.84 | 23 | 11.36 | 3090 | 807 | 2.55 / 504.33 | 2 | 2 |
5 | 13 | 1333.20 | 32 | 12.81 | 2213 | 907 | 3.46 / 505.23 | 2 | 3 |
6 | 13 | 624.20 | 32 | 13.58 | 1217 | 529 | 3.99 / 505.76 | 2 | 3 |
7 | 13 | 28.96 | 32 | 14.31 | 359 | 164 | 4.15 / 505.93 | 2 | 3 |
8 | 8 | 0.16 | 180 | 14.27 | 306 | 786 | 4.94 / 506.71 | 2 | 11 |
Average= | 4.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.68 | 32 | 14.33 | 449 | 206 | 0.21 / 497.02 | 2 | 2 |
2 | 12 | 1106.92 | 8 | 11.92 | 1832 | 175 | 0.38 / 497.19 | 2 | 2 |
3 | 12 | 2008.60 | 41 | 10.57 | 3095 | 1341 | 1.72 / 498.54 | 2 | 2 |
4 | 7 | 2003.28 | 23 | 11.38 | 3108 | 813 | 2.54 / 499.35 | 2 | 2 |
5 | 13 | 1372.20 | 32 | 12.81 | 2265 | 928 | 3.46 / 500.28 | 2 | 3 |
6 | 13 | 659.52 | 32 | 13.58 | 1262 | 548 | 4.01 / 500.83 | 2 | 3 |
7 | 13 | 27.88 | 32 | 14.32 | 357 | 164 | 4.18 / 500.99 | 2 | 3 |
8 | 8 | -0.52 | 180 | 14.26 | 307 | 788 | 4.96 / 501.78 | 2 | 26 |
Average= | 4.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.92 | 32 | 14.34 | 442 | 203 | 0.20 / 492.09 | 2 | 2 |
2 | 3 | 961.48 | -1 | 14.34 | 442 | 0 | 0.00 / 492.09 | 2 | 2 |
3 | 3 | 1019.84 | 1 | 10.07 | 1719 | 17 | 0.22 / 492.10 | 2 | 2 |
4 | 12 | 1134.52 | 5 | 11.56 | 1871 | 108 | 0.33 / 492.21 | 2 | 2 |
5 | 12 | 2002.04 | 43 | 10.60 | 3027 | 1380 | 1.71 / 493.59 | 2 | 2 |
6 | 7 | 1996.60 | 23 | 11.51 | 3085 | 817 | 2.52 / 494.41 | 2 | 2 |
7 | 13 | 1543.12 | 28 | 12.75 | 2480 | 885 | 3.41 / 495.29 | 2 | 2 |
8 | 13 | 853.28 | 28 | 13.41 | 1539 | 578 | 3.99 / 495.87 | 2 | 3 |
9 | 13 | 39.80 | 28 | 14.31 | 378 | 151 | 4.14 / 496.02 | 2 | 3 |
10 | 8 | -0.08 | 180 | 14.29 | 307 | 790 | 4.93 / 496.81 | 2 | 11 |
Average= | 4.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.72 | 32 | 14.36 | 449 | 206 | 0.21 / 487.20 | 2 | 2 |
2 | 3 | 1021.56 | 1 | 10.24 | 1726 | 18 | 0.22 / 487.22 | 2 | 2 |
3 | 12 | 1136.48 | 5 | 10.81 | 1858 | 100 | 0.32 / 487.32 | 2 | 2 |
4 | 12 | 2001.64 | 43 | 10.50 | 2986 | 1348 | 1.67 / 488.67 | 2 | 2 |
5 | 7 | 1996.84 | 23 | 11.49 | 3090 | 817 | 2.49 / 489.48 | 2 | 2 |
6 | 13 | 1559.68 | 28 | 12.75 | 2506 | 895 | 3.38 / 490.38 | 2 | 2 |
7 | 13 | 858.16 | 28 | 13.40 | 1548 | 581 | 3.96 / 490.96 | 2 | 3 |
8 | 13 | 32.64 | 28 | 14.32 | 363 | 146 | 4.11 / 491.10 | 2 | 3 |
9 | 8 | 0.00 | 180 | 14.29 | 303 | 779 | 4.89 / 491.88 | 2 | 11 |
Average= | 4.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.72 | 32 | 14.36 | 450 | 207 | 0.21 / 482.28 | 2 | 2 |
2 | 12 | 1111.80 | 4 | 9.56 | 1819 | 70 | 0.28 / 482.35 | 2 | 2 |
3 | 12 | 2004.36 | 44 | 10.44 | 2989 | 1373 | 1.65 / 483.72 | 2 | 2 |
4 | 7 | 1999.48 | 23 | 11.53 | 3074 | 815 | 2.46 / 484.54 | 2 | 2 |
5 | 13 | 1562.04 | 35 | 12.61 | 2521 | 1113 | 3.58 / 485.65 | 2 | 2 |
6 | 13 | 615.48 | 35 | 13.64 | 1192 | 569 | 4.15 / 486.22 | 2 | 2 |
7 | 8 | -0.12 | 180 | 14.31 | 301 | 775 | 4.92 / 486.99 | 2 | 9 |
Average= | 4.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.36 | 31 | 14.35 | 463 | 206 | 0.21 / 477.17 | 2 | 2 |
2 | 12 | 1136.44 | 4 | 10.20 | 1840 | 75 | 0.28 / 477.25 | 2 | 2 |
3 | 12 | 2001.80 | 44 | 10.56 | 3008 | 1398 | 1.68 / 478.64 | 2 | 2 |
4 | 7 | 1996.56 | 23 | 11.49 | 3104 | 820 | 2.50 / 479.46 | 2 | 2 |
5 | 13 | 1545.88 | 35 | 12.64 | 2490 | 1102 | 3.60 / 480.56 | 2 | 2 |
6 | 13 | 590.80 | 35 | 13.66 | 1156 | 553 | 4.15 / 481.12 | 2 | 3 |
7 | 13 | 22.24 | 35 | 14.34 | 346 | 174 | 4.33 / 481.29 | 2 | 3 |
8 | 8 | -0.44 | 180 | 14.29 | 304 | 782 | 5.11 / 482.07 | 2 | 13 |
Average= | 4.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.24 | 31 | 14.34 | 463 | 206 | 0.21 / 472.24 | 2 | 2 |
2 | 12 | 1119.72 | 3 | 8.61 | 1813 | 47 | 0.25 / 472.29 | 2 | 2 |
3 | 7 | 2004.08 | 49 | 10.39 | 3056 | 1556 | 1.81 / 473.84 | 2 | 2 |
4 | 13 | 1829.64 | 35 | 12.29 | 2873 | 1236 | 3.04 / 475.08 | 2 | 2 |
5 | 13 | 1134.92 | 35 | 13.04 | 1935 | 883 | 3.93 / 475.96 | 2 | 3 |
6 | 13 | 81.24 | 35 | 14.26 | 439 | 219 | 4.15 / 476.18 | 2 | 3 |
7 | 8 | -0.08 | 180 | 14.30 | 305 | 785 | 4.93 / 476.96 | 2 | 14 |
Average= | 4.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.52 | 31 | 14.35 | 460 | 205 | 0.20 / 467.33 | 2 | 2 |
2 | 12 | 1122.12 | 3 | 8.74 | 1808 | 47 | 0.25 / 467.38 | 2 | 2 |
3 | 7 | 2004.40 | 49 | 10.46 | 3056 | 1566 | 1.82 / 468.94 | 2 | 2 |
4 | 13 | 1807.44 | 35 | 12.33 | 2846 | 1228 | 3.05 / 470.17 | 2 | 2 |
5 | 13 | 1093.24 | 35 | 13.08 | 1876 | 859 | 3.91 / 471.03 | 2 | 3 |
6 | 13 | 71.72 | 35 | 14.27 | 418 | 209 | 4.11 / 471.24 | 2 | 3 |
7 | 8 | -0.08 | 180 | 14.28 | 309 | 794 | 4.91 / 472.03 | 2 | 14 |
Average= | 4.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.16 | 31 | 14.33 | 456 | 203 | 0.20 / 462.48 | 2 | 2 |
2 | 12 | 1122.40 | 3 | 9.03 | 1825 | 49 | 0.25 / 462.53 | 2 | 2 |
3 | 7 | 2009.56 | 50 | 10.55 | 3059 | 1614 | 1.87 / 464.14 | 2 | 2 |
4 | 13 | 1819.84 | 35 | 12.35 | 2855 | 1234 | 3.10 / 465.38 | 2 | 2 |
5 | 13 | 923.52 | 35 | 13.28 | 1636 | 760 | 3.86 / 466.14 | 2 | 3 |
6 | 13 | 33.92 | 35 | 14.33 | 370 | 186 | 4.05 / 466.32 | 2 | 3 |
7 | 8 | -0.12 | 180 | 14.27 | 312 | 801 | 4.85 / 467.12 | 2 | 11 |
Average= | 4.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.08 | 31 | 14.36 | 463 | 206 | 0.21 / 457.54 | 2 | 2 |
2 | 12 | 1117.24 | 3 | 9.03 | 1812 | 49 | 0.26 / 457.59 | 2 | 2 |
3 | 7 | 2003.36 | 49 | 10.56 | 3077 | 1592 | 1.85 / 459.18 | 2 | 2 |
4 | 13 | 1810.44 | 35 | 12.34 | 2846 | 1229 | 3.08 / 460.41 | 2 | 2 |
5 | 13 | 1108.28 | 35 | 13.08 | 1894 | 867 | 3.94 / 461.28 | 2 | 2 |
6 | 13 | 77.24 | 35 | 14.27 | 428 | 214 | 4.16 / 461.49 | 2 | 3 |
7 | 8 | -0.16 | 180 | 14.29 | 305 | 785 | 4.94 / 462.28 | 2 | 14 |
Average= | 4.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.08 | 31 | 14.31 | 472 | 209 | 0.21 / 452.58 | 2 | 2 |
2 | 12 | 1101.92 | 3 | 8.40 | 1773 | 45 | 0.25 / 452.63 | 2 | 2 |
3 | 7 | 2008.16 | 50 | 10.51 | 3064 | 1610 | 1.86 / 454.24 | 2 | 2 |
4 | 13 | 1813.36 | 35 | 12.36 | 2852 | 1234 | 3.10 / 455.47 | 2 | 2 |
5 | 13 | 1092.12 | 35 | 13.08 | 1886 | 863 | 3.96 / 456.33 | 2 | 3 |
6 | 13 | 70.96 | 35 | 14.28 | 421 | 210 | 4.17 / 456.54 | 2 | 3 |
7 | 8 | -0.08 | 180 | 14.29 | 308 | 792 | 4.96 / 457.34 | 2 | 12 |
Average= | 4.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.96 | 32 | 14.35 | 468 | 215 | 0.21 / 447.58 | 2 | 2 |
2 | 3 | 957.44 | -1 | 14.35 | 468 | 0 | 0.00 / 447.58 | 2 | 2 |
3 | 12 | 1142.28 | 3 | 9.15 | 1857 | 51 | 0.27 / 447.63 | 2 | 2 |
4 | 7 | 2004.40 | 50 | 10.66 | 3064 | 1633 | 1.90 / 449.26 | 2 | 2 |
5 | 13 | 1810.88 | 35 | 12.39 | 2858 | 1239 | 3.14 / 450.50 | 2 | 2 |
6 | 13 | 1104.20 | 35 | 13.09 | 1900 | 870 | 4.01 / 451.37 | 2 | 3 |
7 | 13 | 32.84 | 35 | 14.33 | 371 | 186 | 4.19 / 451.56 | 2 | 3 |
8 | 8 | 0.04 | 180 | 14.26 | 317 | 814 | 5.01 / 452.37 | 2 | 15 |
Average= | 4.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.32 | 32 | 14.35 | 473 | 217 | 0.22 / 442.59 | 2 | 2 |
2 | 12 | 1107.96 | 3 | 8.35 | 1792 | 45 | 0.26 / 442.63 | 2 | 2 |
3 | 7 | 2002.28 | 49 | 10.56 | 3058 | 1582 | 1.84 / 444.22 | 2 | 2 |
4 | 13 | 1823.80 | 35 | 12.37 | 2868 | 1242 | 3.09 / 445.46 | 2 | 2 |
5 | 13 | 1118.44 | 35 | 13.08 | 1917 | 878 | 3.96 / 446.34 | 2 | 3 |
6 | 13 | 73.12 | 35 | 14.28 | 434 | 217 | 4.18 / 446.55 | 2 | 3 |
7 | 8 | 0.04 | 180 | 14.28 | 315 | 810 | 4.99 / 447.36 | 2 | 10 |
Average= | 4.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.36 | 31 | 14.34 | 473 | 210 | 0.21 / 437.55 | 2 | 2 |
2 | 12 | 1135.96 | 3 | 8.52 | 1833 | 47 | 0.26 / 437.59 | 2 | 2 |
3 | 7 | 2004.96 | 50 | 10.66 | 3088 | 1646 | 1.90 / 439.24 | 2 | 2 |
4 | 13 | 1817.44 | 35 | 12.40 | 2863 | 1243 | 3.15 / 440.48 | 2 | 2 |
5 | 13 | 1095.96 | 35 | 13.11 | 1892 | 868 | 4.01 / 441.35 | 2 | 3 |
6 | 13 | 64.80 | 35 | 14.29 | 418 | 209 | 4.22 / 441.56 | 2 | 3 |
7 | 8 | -0.16 | 180 | 14.27 | 317 | 814 | 5.04 / 442.37 | 2 | 18 |
Average= | 4.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.96 | 31 | 14.34 | 465 | 207 | 0.21 / 432.67 | 2 | 2 |
2 | 12 | 1120.92 | 3 | 8.32 | 1819 | 45 | 0.25 / 432.72 | 2 | 2 |
3 | 7 | 2003.64 | 50 | 10.64 | 3071 | 1634 | 1.89 / 434.35 | 2 | 2 |
4 | 13 | 1807.04 | 35 | 12.41 | 2837 | 1232 | 3.12 / 435.58 | 2 | 2 |
5 | 13 | 910.64 | 35 | 13.29 | 1630 | 758 | 3.88 / 436.34 | 2 | 3 |
6 | 13 | 29.92 | 35 | 14.35 | 367 | 184 | 4.06 / 436.53 | 2 | 3 |
7 | 8 | 0.16 | 180 | 14.26 | 315 | 809 | 4.87 / 437.34 | 2 | 11 |
Average= | 4.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.24 | 31 | 14.33 | 472 | 210 | 0.21 / 427.74 | 2 | 2 |
2 | 12 | 1123.40 | 3 | 7.90 | 1808 | 43 | 0.25 / 427.78 | 2 | 2 |
3 | 7 | 2006.76 | 49 | 10.57 | 3065 | 1587 | 1.84 / 429.37 | 2 | 2 |
4 | 13 | 1807.68 | 35 | 12.43 | 2844 | 1237 | 3.08 / 430.61 | 2 | 2 |
5 | 13 | 1106.64 | 35 | 13.11 | 1897 | 870 | 3.95 / 431.48 | 2 | 3 |
6 | 13 | 36.52 | 35 | 14.34 | 373 | 187 | 4.13 / 431.67 | 2 | 3 |
7 | 8 | -0.04 | 180 | 14.26 | 312 | 801 | 4.94 / 432.47 | 2 | 12 |
Average= | 4.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.72 | 32 | 14.35 | 468 | 215 | 0.21 / 422.70 | 2 | 2 |
2 | 3 | 964.36 | -1 | 14.35 | 468 | 0 | 0.00 / 422.70 | 2 | 2 |
3 | 3 | 1023.36 | 1 | 11.14 | 1761 | 20 | 0.23 / 422.72 | 2 | 2 |
4 | 12 | 1139.04 | 3 | 8.95 | 1847 | 50 | 0.28 / 422.77 | 2 | 2 |
5 | 7 | 2009.72 | 50 | 10.82 | 3078 | 1665 | 1.95 / 424.44 | 2 | 2 |
6 | 13 | 1824.92 | 35 | 12.43 | 2871 | 1249 | 3.20 / 425.69 | 2 | 2 |
7 | 13 | 1103.72 | 35 | 13.11 | 1906 | 875 | 4.07 / 426.56 | 2 | 3 |
8 | 13 | 1.16 | 35 | 14.39 | 326 | 164 | 4.24 / 426.72 | 2 | 4 |
9 | 8 | 0.00 | 180 | 14.21 | 315 | 806 | 5.04 / 427.53 | 2 | 13 |
Average= | 4.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.68 | 31 | 14.32 | 478 | 212 | 0.21 / 417.65 | 2 | 2 |
2 | 3 | 1026.80 | 1 | 11.84 | 1765 | 21 | 0.23 / 417.67 | 2 | 2 |
3 | 12 | 1127.84 | 3 | 9.12 | 1842 | 50 | 0.28 / 417.73 | 2 | 2 |
4 | 7 | 2009.80 | 49 | 10.91 | 3086 | 1650 | 1.93 / 419.37 | 2 | 2 |
5 | 13 | 1816.64 | 35 | 12.46 | 2854 | 1245 | 3.18 / 420.62 | 2 | 2 |
6 | 13 | 1096.48 | 35 | 13.12 | 1891 | 868 | 4.05 / 421.49 | 2 | 3 |
7 | 13 | 33.76 | 35 | 14.33 | 373 | 187 | 4.23 / 421.67 | 2 | 3 |
8 | 8 | -0.12 | 180 | 14.24 | 317 | 813 | 5.05 / 422.49 | 2 | 13 |
Average= | 4.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.24 | 32 | 14.35 | 468 | 215 | 0.21 / 412.80 | 2 | 2 |
2 | 3 | 957.52 | -1 | 14.35 | 468 | 0 | 0.00 / 412.80 | 2 | 2 |
3 | 3 | 1025.80 | 1 | 11.12 | 1753 | 19 | 0.23 / 412.82 | 2 | 2 |
4 | 12 | 1141.48 | 3 | 8.54 | 1846 | 47 | 0.28 / 412.86 | 2 | 2 |
5 | 7 | 2002.04 | 50 | 10.94 | 3081 | 1685 | 1.97 / 414.55 | 2 | 2 |
6 | 13 | 1785.76 | 35 | 12.48 | 2809 | 1227 | 3.19 / 415.78 | 2 | 2 |
7 | 13 | 1076.56 | 35 | 13.14 | 1864 | 857 | 4.05 / 416.63 | 2 | 3 |
8 | 8 | 0.04 | 180 | 14.26 | 315 | 809 | 4.86 / 417.44 | 2 | 7 |
Average= | 4.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.08 | 32 | 14.33 | 482 | 221 | 0.22 / 407.83 | 2 | 2 |
2 | 12 | 1131.60 | 3 | 8.42 | 1827 | 46 | 0.27 / 407.88 | 2 | 2 |
3 | 7 | 2008.12 | 49 | 10.91 | 3078 | 1645 | 1.91 / 409.52 | 2 | 2 |
4 | 13 | 1804.96 | 35 | 12.49 | 2846 | 1244 | 3.16 / 410.77 | 2 | 2 |
5 | 13 | 1082.44 | 35 | 13.15 | 1865 | 858 | 4.02 / 411.62 | 2 | 3 |
6 | 13 | 3.88 | 35 | 14.38 | 324 | 163 | 4.18 / 411.79 | 2 | 2 |
7 | 8 | 0.16 | 180 | 14.23 | 310 | 794 | 4.97 / 412.58 | 2 | 11 |
Average= | 4.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.96 | 32 | 14.32 | 492 | 225 | 0.23 / 402.79 | 2 | 2 |
2 | 12 | 1123.84 | 3 | 8.32 | 1808 | 45 | 0.27 / 402.84 | 2 | 2 |
3 | 7 | 2008.44 | 50 | 10.93 | 3084 | 1685 | 1.96 / 404.52 | 2 | 2 |
4 | 13 | 1809.44 | 35 | 12.50 | 2853 | 1248 | 3.20 / 405.77 | 2 | 2 |
5 | 13 | 1103.48 | 35 | 13.14 | 1891 | 870 | 4.07 / 406.64 | 2 | 3 |
6 | 13 | 14.60 | 35 | 14.36 | 340 | 171 | 4.24 / 406.81 | 2 | 3 |
7 | 8 | 0.00 | 180 | 14.21 | 312 | 798 | 5.04 / 407.61 | 2 | 15 |
Average= | 4.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.80 | 32 | 14.32 | 493 | 226 | 0.23 / 397.80 | 2 | 2 |
2 | 12 | 1122.28 | 3 | 8.10 | 1817 | 44 | 0.27 / 397.85 | 2 | 2 |
3 | 7 | 2001.60 | 49 | 10.92 | 3083 | 1650 | 1.92 / 399.50 | 2 | 2 |
4 | 13 | 1796.48 | 35 | 12.53 | 2825 | 1239 | 3.16 / 400.74 | 2 | 2 |
5 | 13 | 1080.08 | 35 | 13.16 | 1877 | 865 | 4.02 / 401.60 | 2 | 3 |
6 | 13 | 3.20 | 35 | 14.38 | 327 | 165 | 4.19 / 401.77 | 2 | 4 |
7 | 8 | 0.08 | 180 | 14.22 | 313 | 801 | 4.99 / 402.57 | 2 | 14 |
Average= | 4.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.68 | 32 | 14.36 | 498 | 229 | 0.23 / 392.96 | 2 | 2 |
2 | 12 | 1126.52 | 3 | 7.72 | 1825 | 42 | 0.27 / 393.01 | 2 | 2 |
3 | 7 | 2014.32 | 49 | 10.80 | 3117 | 1650 | 1.92 / 394.66 | 2 | 2 |
4 | 13 | 1821.24 | 35 | 12.51 | 2859 | 1252 | 3.17 / 395.91 | 2 | 2 |
5 | 13 | 1087.40 | 35 | 13.16 | 1872 | 862 | 4.03 / 396.77 | 2 | 3 |
6 | 8 | 0.20 | 180 | 14.26 | 315 | 809 | 4.84 / 397.58 | 2 | 8 |
Average= | 4.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.28 | 32 | 14.33 | 484 | 222 | 0.22 / 387.90 | 2 | 2 |
2 | 12 | 1124.36 | 3 | 7.80 | 1817 | 43 | 0.26 / 387.95 | 2 | 2 |
3 | 7 | 2003.76 | 49 | 10.83 | 3073 | 1631 | 1.90 / 389.58 | 2 | 2 |
4 | 13 | 1817.08 | 35 | 12.52 | 2872 | 1259 | 3.15 / 390.83 | 2 | 2 |
5 | 13 | 1105.00 | 35 | 13.17 | 1902 | 877 | 4.03 / 391.71 | 2 | 3 |
6 | 13 | 70.12 | 35 | 14.29 | 430 | 215 | 4.25 / 391.93 | 2 | 4 |
7 | 8 | 0.04 | 180 | 14.26 | 315 | 809 | 5.05 / 392.73 | 2 | 16 |
Average= | 4.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.48 | 32 | 14.36 | 489 | 225 | 0.22 / 382.91 | 2 | 2 |
2 | 12 | 1111.40 | 3 | 7.68 | 1801 | 41 | 0.27 / 382.95 | 2 | 2 |
3 | 7 | 2002.52 | 49 | 10.84 | 3060 | 1625 | 1.89 / 384.57 | 2 | 2 |
4 | 13 | 1807.48 | 35 | 12.54 | 2839 | 1246 | 3.14 / 385.82 | 2 | 2 |
5 | 13 | 1106.40 | 35 | 13.17 | 1905 | 878 | 4.02 / 386.70 | 2 | 3 |
6 | 13 | 23.44 | 35 | 14.37 | 355 | 179 | 4.19 / 386.88 | 2 | 4 |
7 | 8 | -0.12 | 180 | 14.26 | 313 | 803 | 5.00 / 387.68 | 2 | 14 |
Average= | 4.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.40 | 32 | 14.39 | 465 | 214 | 0.21 / 377.95 | 2 | 2 |
2 | 12 | 1106.68 | 3 | 7.41 | 1798 | 40 | 0.25 / 377.99 | 2 | 2 |
3 | 7 | 2002.48 | 50 | 10.73 | 3076 | 1650 | 1.90 / 379.64 | 2 | 2 |
4 | 13 | 1798.24 | 35 | 12.58 | 2804 | 1235 | 3.14 / 380.88 | 2 | 2 |
5 | 13 | 1070.80 | 35 | 13.20 | 1845 | 852 | 3.99 / 381.73 | 2 | 3 |
6 | 13 | 5.88 | 35 | 14.40 | 325 | 164 | 4.16 / 381.89 | 2 | 3 |
7 | 8 | 0.08 | 180 | 14.24 | 308 | 789 | 4.94 / 382.68 | 2 | 17 |
Average= | 4.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.24 | 32 | 14.39 | 488 | 225 | 0.22 / 373.01 | 2 | 2 |
2 | 12 | 1123.12 | 3 | 6.92 | 1953 | 41 | 0.27 / 373.05 | 2 | 2 |
3 | 7 | 2006.28 | 49 | 10.62 | 3070 | 1598 | 1.86 / 374.65 | 2 | 2 |
4 | 13 | 1806.92 | 35 | 12.56 | 2843 | 1250 | 3.11 / 375.90 | 2 | 2 |
5 | 13 | 1102.00 | 35 | 13.18 | 1885 | 870 | 3.98 / 376.77 | 2 | 3 |
6 | 13 | 33.00 | 35 | 14.38 | 362 | 182 | 4.16 / 376.95 | 2 | 3 |
7 | 8 | 0.36 | 180 | 14.28 | 306 | 787 | 4.95 / 377.74 | 2 | 13 |
Average= | 4.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.20 | 32 | 14.40 | 471 | 217 | 0.22 / 368.03 | 2 | 2 |
2 | 12 | 1121.84 | 3 | 7.45 | 1814 | 41 | 0.26 / 368.07 | 2 | 2 |
3 | 7 | 2001.64 | 49 | 10.64 | 3075 | 1603 | 1.86 / 369.68 | 2 | 2 |
4 | 13 | 1806.44 | 35 | 12.58 | 2813 | 1239 | 3.10 / 370.91 | 2 | 2 |
5 | 13 | 1101.92 | 35 | 13.19 | 1895 | 875 | 3.97 / 371.79 | 2 | 3 |
6 | 13 | 35.80 | 35 | 14.37 | 378 | 190 | 4.16 / 371.98 | 2 | 3 |
7 | 8 | -0.20 | 180 | 14.26 | 315 | 809 | 4.97 / 372.79 | 2 | 12 |
Average= | 4.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.08 | 32 | 14.42 | 456 | 210 | 0.21 / 362.89 | 2 | 2 |
2 | 12 | 1114.40 | 3 | 7.63 | 1800 | 41 | 0.25 / 362.94 | 2 | 2 |
3 | 7 | 2008.12 | 50 | 10.62 | 3082 | 1637 | 1.89 / 364.57 | 2 | 2 |
4 | 13 | 1810.48 | 35 | 12.59 | 2832 | 1248 | 3.14 / 365.82 | 2 | 2 |
5 | 13 | 1078.40 | 35 | 13.22 | 1871 | 866 | 4.00 / 366.69 | 2 | 3 |
6 | 13 | 16.76 | 35 | 14.40 | 347 | 175 | 4.18 / 366.86 | 2 | 3 |
7 | 13 | 6.28 | 35 | 14.33 | 323 | 162 | 4.34 / 367.02 | 2 | 4 |
8 | 8 | -0.16 | 180 | 14.24 | 309 | 792 | 5.13 / 367.81 | 2 | 15 |
Average= | 4.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.32 | 32 | 14.42 | 463 | 214 | 0.21 / 357.92 | 2 | 2 |
2 | 12 | 1112.72 | 3 | 8.16 | 1816 | 44 | 0.26 / 357.96 | 2 | 2 |
3 | 7 | 2006.84 | 49 | 10.75 | 3086 | 1626 | 1.88 / 359.59 | 2 | 2 |
4 | 13 | 1808.88 | 35 | 12.58 | 2852 | 1256 | 3.14 / 360.84 | 2 | 2 |
5 | 13 | 1094.44 | 35 | 13.22 | 1881 | 870 | 4.01 / 361.71 | 2 | 3 |
6 | 13 | 37.44 | 35 | 14.39 | 368 | 185 | 4.20 / 361.90 | 2 | 3 |
7 | 8 | -0.08 | 180 | 14.29 | 306 | 787 | 4.98 / 362.68 | 2 | 11 |
Average= | 4.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.00 | 32 | 14.40 | 469 | 216 | 0.22 / 353.03 | 2 | 2 |
2 | 12 | 1121.96 | 3 | 7.97 | 1820 | 44 | 0.26 / 353.07 | 2 | 2 |
3 | 7 | 2002.56 | 49 | 10.70 | 3091 | 1621 | 1.88 / 354.69 | 2 | 2 |
4 | 13 | 1807.84 | 35 | 12.59 | 2861 | 1261 | 3.14 / 355.95 | 2 | 2 |
5 | 13 | 895.44 | 35 | 13.40 | 1616 | 758 | 3.90 / 356.71 | 2 | 3 |
6 | 13 | 37.48 | 35 | 14.38 | 376 | 189 | 4.09 / 356.90 | 2 | 3 |
7 | 8 | 0.12 | 180 | 14.28 | 312 | 802 | 4.89 / 357.70 | 2 | 14 |
Average= | 4.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.64 | 31 | 14.44 | 459 | 205 | 0.21 / 347.96 | 2 | 2 |
2 | 12 | 1121.76 | 3 | 8.84 | 1800 | 48 | 0.25 / 348.01 | 2 | 2 |
3 | 7 | 2012.60 | 49 | 10.80 | 3094 | 1637 | 1.89 / 349.65 | 2 | 2 |
4 | 13 | 1836.28 | 35 | 12.58 | 2874 | 1265 | 3.16 / 350.91 | 2 | 2 |
5 | 13 | 1115.20 | 35 | 13.20 | 1911 | 883 | 4.04 / 351.80 | 2 | 3 |
6 | 13 | 81.20 | 35 | 14.33 | 436 | 219 | 4.26 / 352.01 | 2 | 3 |
7 | 8 | -0.08 | 180 | 14.29 | 310 | 797 | 5.05 / 352.81 | 2 | 12 |
Average= | 4.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.04 | 31 | 14.44 | 467 | 209 | 0.21 / 342.99 | 2 | 2 |
2 | 12 | 1137.08 | 3 | 8.93 | 1835 | 49 | 0.26 / 343.04 | 2 | 2 |
3 | 7 | 2004.32 | 49 | 10.87 | 3080 | 1641 | 1.90 / 344.68 | 2 | 2 |
4 | 13 | 1808.96 | 35 | 12.60 | 2846 | 1255 | 3.15 / 345.94 | 2 | 2 |
5 | 13 | 1086.00 | 35 | 13.24 | 1863 | 863 | 4.02 / 346.80 | 2 | 3 |
6 | 13 | 33.28 | 35 | 14.40 | 364 | 183 | 4.20 / 346.98 | 2 | 3 |
7 | 8 | 0.12 | 180 | 14.30 | 300 | 772 | 4.97 / 347.76 | 2 | 11 |
Average= | 4.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.60 | 31 | 14.48 | 444 | 199 | 0.20 / 338.14 | 2 | 2 |
2 | 12 | 1116.52 | 3 | 8.89 | 1810 | 48 | 0.25 / 338.19 | 2 | 2 |
3 | 7 | 2007.64 | 50 | 10.89 | 3084 | 1679 | 1.93 / 339.87 | 2 | 2 |
4 | 13 | 1618.00 | 35 | 12.79 | 2589 | 1159 | 3.09 / 341.03 | 2 | 2 |
5 | 13 | 920.60 | 35 | 13.39 | 1652 | 774 | 3.86 / 341.80 | 2 | 3 |
6 | 13 | 34.28 | 35 | 14.39 | 373 | 188 | 4.05 / 341.99 | 2 | 4 |
7 | 8 | -0.08 | 180 | 14.28 | 310 | 797 | 4.84 / 342.78 | 2 | 15 |
Average= | 4.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.08 | 31 | 14.48 | 456 | 205 | 0.20 / 333.14 | 2 | 2 |
2 | 12 | 1120.20 | 3 | 9.50 | 1827 | 52 | 0.26 / 333.19 | 2 | 2 |
3 | 7 | 2004.00 | 50 | 10.91 | 3096 | 1689 | 1.95 / 334.88 | 2 | 2 |
4 | 13 | 1794.04 | 35 | 12.66 | 2808 | 1244 | 3.19 / 336.12 | 2 | 2 |
5 | 13 | 1057.96 | 35 | 13.28 | 1827 | 849 | 4.04 / 336.97 | 2 | 3 |
6 | 13 | 51.64 | 35 | 14.38 | 387 | 195 | 4.23 / 337.16 | 2 | 3 |
7 | 8 | -0.04 | 180 | 14.30 | 301 | 775 | 5.01 / 337.94 | 2 | 14 |
Average= | 4.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.52 | 31 | 14.48 | 463 | 208 | 0.21 / 328.24 | 2 | 2 |
2 | 12 | 1124.92 | 3 | 9.52 | 1853 | 53 | 0.26 / 328.30 | 2 | 2 |
3 | 7 | 2003.64 | 49 | 10.99 | 3080 | 1659 | 1.92 / 329.95 | 2 | 2 |
4 | 13 | 1793.32 | 35 | 12.64 | 2823 | 1249 | 3.17 / 331.20 | 2 | 2 |
5 | 13 | 878.72 | 35 | 13.44 | 1582 | 744 | 3.91 / 331.95 | 2 | 3 |
6 | 13 | 40.56 | 35 | 14.39 | 381 | 192 | 4.10 / 332.14 | 2 | 3 |
7 | 8 | -0.08 | 180 | 14.28 | 308 | 792 | 4.90 / 332.93 | 2 | 9 |
Average= | 4.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.00 | 31 | 14.50 | 445 | 200 | 0.20 / 323.34 | 2 | 2 |
2 | 12 | 1123.12 | 3 | 10.01 | 1846 | 55 | 0.26 / 323.39 | 2 | 2 |
3 | 7 | 2008.20 | 49 | 11.05 | 3093 | 1675 | 1.93 / 325.07 | 2 | 2 |
4 | 13 | 1800.68 | 35 | 12.66 | 2825 | 1252 | 3.18 / 326.32 | 2 | 2 |
5 | 13 | 883.36 | 35 | 13.44 | 1582 | 744 | 3.93 / 327.06 | 2 | 3 |
6 | 13 | 34.80 | 35 | 14.39 | 370 | 186 | 4.11 / 327.25 | 2 | 4 |
7 | 8 | -0.12 | 180 | 14.28 | 306 | 787 | 4.90 / 328.03 | 2 | 14 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.60 | 31 | 14.49 | 472 | 212 | 0.21 / 318.52 | 2 | 2 |
2 | 12 | 1118.72 | 3 | 10.47 | 1847 | 58 | 0.27 / 318.58 | 2 | 2 |
3 | 7 | 2010.32 | 49 | 11.10 | 3094 | 1683 | 1.95 / 320.27 | 2 | 2 |
4 | 13 | 1808.48 | 31 | 12.73 | 2838 | 1120 | 3.07 / 321.39 | 2 | 2 |
5 | 13 | 1094.80 | 31 | 13.31 | 1882 | 777 | 3.85 / 322.16 | 2 | 3 |
6 | 13 | 84.32 | 31 | 14.35 | 439 | 195 | 4.04 / 322.36 | 2 | 3 |
7 | 8 | -0.04 | 180 | 14.33 | 302 | 779 | 4.82 / 323.14 | 2 | 10 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.04 | 31 | 14.47 | 464 | 208 | 0.21 / 313.66 | 2 | 2 |
2 | 12 | 1108.76 | 3 | 10.95 | 1846 | 61 | 0.27 / 313.72 | 2 | 2 |
3 | 7 | 2016.28 | 50 | 11.09 | 3111 | 1725 | 1.99 / 315.45 | 2 | 2 |
4 | 13 | 1799.04 | 31 | 12.75 | 2831 | 1119 | 3.11 / 316.57 | 2 | 2 |
5 | 13 | 1068.60 | 31 | 13.34 | 1847 | 764 | 3.88 / 317.33 | 2 | 3 |
6 | 13 | 74.52 | 31 | 14.37 | 426 | 190 | 4.07 / 317.52 | 2 | 3 |
7 | 8 | 0.08 | 180 | 14.32 | 307 | 791 | 4.86 / 318.31 | 2 | 11 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.56 | 31 | 14.51 | 452 | 203 | 0.20 / 308.89 | 2 | 2 |
2 | 12 | 1112.36 | 3 | 11.28 | 1852 | 63 | 0.27 / 308.95 | 2 | 2 |
3 | 7 | 2002.92 | 49 | 11.21 | 3094 | 1700 | 1.97 / 310.65 | 2 | 2 |
4 | 13 | 1600.60 | 31 | 12.90 | 2570 | 1028 | 2.99 / 311.68 | 2 | 2 |
5 | 13 | 1137.60 | 31 | 13.30 | 1948 | 803 | 3.80 / 312.48 | 2 | 3 |
6 | 13 | 79.72 | 31 | 14.36 | 434 | 193 | 3.99 / 312.67 | 2 | 3 |
7 | 8 | -0.12 | 180 | 14.33 | 303 | 782 | 4.77 / 313.45 | 2 | 11 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.00 | 31 | 14.50 | 448 | 201 | 0.20 / 304.01 | 2 | 2 |
2 | 12 | 1119.44 | 3 | 11.53 | 1877 | 65 | 0.27 / 304.07 | 2 | 2 |
3 | 7 | 2005.16 | 50 | 11.27 | 3090 | 1741 | 2.01 / 305.81 | 2 | 2 |
4 | 13 | 1795.96 | 31 | 12.77 | 2813 | 1114 | 3.12 / 306.93 | 2 | 2 |
5 | 13 | 1052.04 | 31 | 13.38 | 1839 | 763 | 3.88 / 307.69 | 2 | 3 |
6 | 13 | 63.84 | 31 | 14.37 | 425 | 189 | 4.07 / 307.88 | 2 | 3 |
7 | 8 | -0.20 | 180 | 14.31 | 312 | 804 | 4.88 / 308.68 | 2 | 15 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.16 | 31 | 14.51 | 450 | 202 | 0.20 / 299.15 | 2 | 2 |
2 | 12 | 1121.88 | 3 | 12.21 | 1862 | 68 | 0.27 / 299.21 | 2 | 2 |
3 | 7 | 2006.72 | 49 | 11.38 | 3103 | 1730 | 2.00 / 300.94 | 2 | 2 |
4 | 13 | 1797.52 | 31 | 12.78 | 2839 | 1125 | 3.13 / 302.07 | 2 | 2 |
5 | 13 | 1059.24 | 31 | 13.38 | 1843 | 764 | 3.89 / 302.83 | 2 | 3 |
6 | 13 | 61.16 | 31 | 14.39 | 408 | 182 | 4.07 / 303.02 | 2 | 3 |
7 | 8 | 0.12 | 180 | 14.32 | 307 | 791 | 4.86 / 303.81 | 2 | 13 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.36 | 31 | 14.45 | 479 | 215 | 0.21 / 294.41 | 2 | 2 |
2 | 12 | 1134.28 | 3 | 12.24 | 1889 | 69 | 0.28 / 294.48 | 2 | 2 |
3 | 7 | 2020.04 | 50 | 11.39 | 3118 | 1776 | 2.06 / 296.25 | 2 | 2 |
4 | 13 | 1605.40 | 31 | 12.95 | 2576 | 1034 | 3.09 / 297.29 | 2 | 2 |
5 | 13 | 911.24 | 31 | 13.52 | 1639 | 687 | 3.78 / 297.97 | 2 | 3 |
6 | 13 | 62.88 | 31 | 14.39 | 413 | 184 | 3.96 / 298.16 | 2 | 3 |
7 | 8 | -0.08 | 180 | 14.33 | 305 | 787 | 4.75 / 298.94 | 2 | 16 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.08 | 31 | 14.50 | 447 | 201 | 0.20 / 289.58 | 2 | 2 |
2 | 12 | 1126.68 | 3 | 12.13 | 1886 | 69 | 0.27 / 289.65 | 2 | 2 |
3 | 7 | 2002.16 | 49 | 11.43 | 3091 | 1731 | 2.00 / 291.38 | 2 | 2 |
4 | 13 | 1781.68 | 31 | 12.83 | 2787 | 1108 | 3.11 / 292.49 | 2 | 2 |
5 | 13 | 1055.88 | 31 | 13.41 | 1833 | 762 | 3.87 / 293.25 | 2 | 3 |
6 | 13 | 33.56 | 31 | 14.44 | 361 | 162 | 4.03 / 293.41 | 2 | 3 |
7 | 8 | -0.04 | 180 | 14.30 | 302 | 777 | 4.81 / 294.19 | 2 | 10 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.96 | 31 | 14.48 | 469 | 211 | 0.21 / 284.85 | 2 | 2 |
2 | 12 | 1136.24 | 3 | 12.39 | 1904 | 71 | 0.28 / 284.92 | 2 | 2 |
3 | 7 | 2004.64 | 49 | 11.48 | 3090 | 1738 | 2.02 / 286.66 | 2 | 2 |
4 | 13 | 1786.44 | 31 | 12.81 | 2817 | 1119 | 3.14 / 287.78 | 2 | 2 |
5 | 13 | 833.00 | 31 | 13.61 | 1526 | 644 | 3.78 / 288.42 | 2 | 3 |
6 | 13 | 65.08 | 31 | 14.41 | 412 | 184 | 3.97 / 288.61 | 2 | 3 |
7 | 8 | -0.04 | 180 | 14.31 | 301 | 775 | 4.74 / 289.38 | 2 | 13 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.00 | 31 | 14.50 | 455 | 205 | 0.20 / 280.14 | 2 | 2 |
2 | 12 | 1117.60 | 3 | 12.46 | 1873 | 70 | 0.27 / 280.21 | 2 | 2 |
3 | 7 | 2006.92 | 50 | 11.54 | 3104 | 1791 | 2.07 / 282.00 | 2 | 2 |
4 | 13 | 1596.20 | 31 | 12.97 | 2574 | 1035 | 3.10 / 283.04 | 2 | 2 |
5 | 13 | 888.64 | 31 | 13.57 | 1606 | 676 | 3.78 / 283.71 | 2 | 3 |
6 | 13 | 1.68 | 31 | 14.49 | 319 | 143 | 3.92 / 283.86 | 2 | 3 |
7 | 8 | 0.00 | 180 | 14.29 | 304 | 782 | 4.70 / 284.64 | 2 | 13 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.84 | 31 | 14.49 | 471 | 212 | 0.21 / 275.47 | 2 | 2 |
2 | 12 | 1137.08 | 3 | 12.51 | 1898 | 71 | 0.28 / 275.54 | 2 | 2 |
3 | 7 | 2005.48 | 49 | 11.65 | 3100 | 1770 | 2.05 / 277.31 | 2 | 2 |
4 | 13 | 1591.20 | 31 | 13.01 | 2556 | 1031 | 3.08 / 278.34 | 2 | 2 |
5 | 13 | 895.08 | 31 | 13.58 | 1614 | 679 | 3.76 / 279.02 | 2 | 3 |
6 | 13 | 5.20 | 31 | 14.48 | 320 | 144 | 3.91 / 279.16 | 2 | 4 |
7 | 8 | 0.20 | 180 | 14.30 | 301 | 775 | 4.68 / 279.94 | 2 | 17 |
Average= | 4.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.32 | 31 | 14.49 | 467 | 210 | 0.21 / 270.78 | 2 | 2 |
2 | 12 | 1131.64 | 3 | 12.46 | 1892 | 71 | 0.28 / 270.85 | 2 | 2 |
3 | 7 | 2003.32 | 49 | 11.66 | 3093 | 1767 | 2.05 / 272.62 | 2 | 2 |
4 | 13 | 1588.64 | 31 | 13.02 | 2549 | 1029 | 3.08 / 273.65 | 2 | 2 |
5 | 13 | 880.24 | 31 | 13.59 | 1594 | 672 | 3.75 / 274.32 | 2 | 3 |
6 | 13 | 15.56 | 31 | 14.46 | 338 | 152 | 3.90 / 274.47 | 2 | 3 |
7 | 8 | -0.16 | 180 | 14.27 | 306 | 786 | 4.69 / 275.26 | 2 | 15 |
Average= | 4.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.64 | 31 | 14.43 | 459 | 205 | 0.21 / 266.08 | 2 | 2 |
2 | 12 | 1126.92 | 3 | 12.61 | 1899 | 72 | 0.28 / 266.15 | 2 | 2 |
3 | 7 | 2002.36 | 49 | 11.77 | 3099 | 1787 | 2.06 / 267.94 | 2 | 2 |
4 | 13 | 1586.60 | 31 | 13.04 | 2544 | 1028 | 3.09 / 268.97 | 2 | 2 |
5 | 13 | 874.36 | 31 | 13.58 | 1590 | 669 | 3.76 / 269.64 | 2 | 4 |
6 | 13 | 1.72 | 31 | 14.47 | 320 | 144 | 3.91 / 269.78 | 2 | 2 |
7 | 8 | 0.04 | 180 | 14.27 | 307 | 789 | 4.69 / 270.57 | 2 | 11 |
Average= | 4.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.64 | 31 | 14.41 | 477 | 213 | 0.21 / 261.52 | 2 | 2 |
2 | 12 | 1121.72 | 3 | 12.51 | 1882 | 71 | 0.28 / 261.59 | 2 | 2 |
3 | 7 | 2012.04 | 49 | 11.75 | 3109 | 1790 | 2.07 / 263.38 | 2 | 2 |
4 | 13 | 1590.56 | 31 | 13.06 | 2534 | 1026 | 3.10 / 264.40 | 2 | 2 |
5 | 13 | 864.88 | 31 | 13.58 | 1579 | 665 | 3.76 / 265.07 | 2 | 4 |
6 | 8 | 0.12 | 180 | 14.25 | 316 | 811 | 4.57 / 265.88 | 2 | 12 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.76 | 31 | 14.42 | 477 | 213 | 0.21 / 256.67 | 2 | 2 |
2 | 12 | 1121.76 | 3 | 12.58 | 1906 | 72 | 0.29 / 256.74 | 2 | 2 |
3 | 7 | 2005.20 | 50 | 11.81 | 3099 | 1830 | 2.12 / 258.57 | 2 | 2 |
4 | 13 | 1783.68 | 31 | 12.91 | 2791 | 1117 | 3.23 / 259.69 | 2 | 2 |
5 | 13 | 801.72 | 31 | 13.64 | 1489 | 630 | 3.86 / 260.32 | 2 | 4 |
6 | 13 | 30.08 | 31 | 14.39 | 378 | 169 | 4.03 / 260.49 | 2 | 4 |
7 | 8 | 0.32 | 180 | 14.22 | 319 | 817 | 4.85 / 261.30 | 2 | 12 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.84 | 29 | 14.43 | 483 | 202 | 0.20 / 251.86 | 2 | 2 |
2 | 3 | 1030.24 | 1 | 13.58 | 1822 | 25 | 0.23 / 251.89 | 2 | 2 |
3 | 3 | 1029.60 | 1 | 13.48 | 1834 | 25 | 0.25 / 251.91 | 2 | 2 |
4 | 12 | 1119.56 | 3 | 12.71 | 1893 | 72 | 0.32 / 251.98 | 2 | 2 |
5 | 7 | 2002.20 | 49 | 11.82 | 3108 | 1800 | 2.12 / 253.78 | 2 | 2 |
6 | 13 | 1563.08 | 31 | 13.10 | 2497 | 1014 | 3.14 / 254.80 | 2 | 2 |
7 | 13 | 842.96 | 31 | 13.59 | 1553 | 654 | 3.79 / 255.45 | 2 | 4 |
8 | 13 | 30.80 | 31 | 14.35 | 385 | 171 | 3.96 / 255.62 | 2 | 5 |
9 | 8 | -0.08 | 180 | 14.18 | 326 | 832 | 4.80 / 256.46 | 2 | 15 |
Average= | 4.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.88 | 28 | 14.37 | 490 | 197 | 0.20 / 246.94 | 2 | 2 |
2 | 3 | 1036.60 | 1 | 13.85 | 1835 | 25 | 0.22 / 246.96 | 2 | 2 |
3 | 7 | 2004.64 | 49 | 12.15 | 3105 | 1849 | 2.07 / 248.81 | 2 | 2 |
4 | 13 | 1795.28 | 32 | 12.98 | 2850 | 1184 | 3.25 / 249.99 | 2 | 2 |
5 | 13 | 845.64 | 32 | 13.61 | 1565 | 682 | 3.94 / 250.68 | 2 | 4 |
6 | 13 | 16.24 | 32 | 14.39 | 357 | 164 | 4.10 / 250.84 | 2 | 4 |
7 | 8 | 0.12 | 180 | 14.19 | 321 | 820 | 4.92 / 251.66 | 2 | 13 |
Average= | 4.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.76 | 29 | 14.33 | 495 | 206 | 0.21 / 242.30 | 2 | 2 |
2 | 3 | 942.24 | -1 | 14.33 | 495 | 0 | 0.00 / 242.30 | 2 | 2 |
3 | 7 | 2008.80 | 49 | 12.23 | 3118 | 1869 | 2.07 / 244.17 | 2 | 2 |
4 | 13 | 1572.76 | 32 | 13.16 | 2513 | 1058 | 3.13 / 245.23 | 2 | 2 |
5 | 13 | 848.64 | 32 | 13.61 | 1559 | 679 | 3.81 / 245.91 | 2 | 4 |
6 | 8 | 0.16 | 180 | 14.18 | 327 | 835 | 4.65 / 246.74 | 2 | 12 |
Average= | 4.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.92 | 29 | 14.28 | 485 | 201 | 0.20 / 237.68 | 2 | 2 |
2 | 7 | 2006.16 | 43 | 12.43 | 3109 | 1662 | 1.86 / 239.35 | 2 | 2 |
3 | 13 | 1803.00 | 25 | 13.10 | 2857 | 936 | 2.80 / 240.28 | 2 | 2 |
4 | 13 | 1100.52 | 25 | 13.52 | 1903 | 643 | 3.44 / 240.92 | 2 | 3 |
5 | 13 | 387.52 | 25 | 13.97 | 921 | 322 | 3.76 / 241.25 | 2 | 5 |
6 | 8 | 0.36 | 180 | 14.14 | 333 | 848 | 4.61 / 242.09 | 2 | 10 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.20 | 29 | 14.30 | 502 | 208 | 0.21 / 233.13 | 2 | 2 |
2 | 7 | 2003.76 | 42 | 12.56 | 3108 | 1640 | 1.85 / 234.77 | 2 | 2 |
3 | 13 | 1600.60 | 35 | 13.10 | 2565 | 1176 | 3.02 / 235.94 | 2 | 2 |
4 | 13 | 681.44 | 35 | 13.67 | 1316 | 630 | 3.65 / 236.57 | 2 | 4 |
5 | 8 | 0.04 | 190 | 14.07 | 340 | 909 | 4.56 / 237.48 | 2 | 11 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.24 | 29 | 14.32 | 485 | 201 | 0.20 / 228.57 | 2 | 2 |
2 | 7 | 2003.24 | 42 | 12.64 | 3105 | 1648 | 1.85 / 230.22 | 2 | 2 |
3 | 13 | 1596.32 | 35 | 13.11 | 2542 | 1166 | 3.02 / 231.38 | 2 | 2 |
4 | 13 | 674.48 | 35 | 13.68 | 1302 | 623 | 3.64 / 232.01 | 2 | 4 |
5 | 8 | 0.08 | 190 | 14.08 | 341 | 912 | 4.55 / 232.92 | 2 | 14 |
Average= | 4.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.12 | 29 | 14.32 | 509 | 211 | 0.21 / 223.98 | 2 | 2 |
2 | 7 | 2005.92 | 42 | 12.75 | 3103 | 1662 | 1.87 / 225.64 | 2 | 2 |
3 | 13 | 1601.60 | 35 | 13.12 | 2564 | 1177 | 3.05 / 226.82 | 2 | 2 |
4 | 13 | 685.92 | 35 | 13.67 | 1334 | 638 | 3.69 / 227.46 | 2 | 4 |
5 | 8 | 0.00 | 190 | 14.11 | 339 | 909 | 4.60 / 228.37 | 2 | 15 |
Average= | 4.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.24 | 29 | 14.35 | 488 | 203 | 0.20 / 219.34 | 2 | 2 |
2 | 7 | 2006.84 | 43 | 12.79 | 3106 | 1708 | 1.91 / 221.05 | 2 | 2 |
3 | 13 | 1616.48 | 35 | 13.13 | 2573 | 1182 | 3.09 / 222.23 | 2 | 2 |
4 | 13 | 669.52 | 35 | 13.70 | 1297 | 622 | 3.72 / 222.85 | 2 | 4 |
5 | 8 | 0.16 | 190 | 14.12 | 342 | 918 | 4.63 / 223.77 | 2 | 9 |
Average= | 4.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.72 | 29 | 14.34 | 493 | 205 | 0.21 / 214.91 | 2 | 2 |
2 | 7 | 2007.84 | 42 | 12.87 | 3119 | 1686 | 1.89 / 216.60 | 2 | 2 |
3 | 13 | 1407.72 | 35 | 13.25 | 2314 | 1073 | 2.96 / 217.67 | 2 | 2 |
4 | 13 | 523.16 | 35 | 13.80 | 1116 | 539 | 3.50 / 218.21 | 2 | 5 |
5 | 8 | 0.08 | 190 | 14.12 | 345 | 926 | 4.43 / 219.14 | 2 | 8 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.40 | 30 | 14.32 | 500 | 215 | 0.21 / 210.03 | 2 | 2 |
2 | 3 | 942.76 | -1 | 14.32 | 500 | 0 | 0.00 / 210.03 | 2 | 2 |
3 | 7 | 2003.00 | 43 | 12.90 | 3111 | 1726 | 1.94 / 211.75 | 2 | 2 |
4 | 13 | 1806.80 | 35 | 13.03 | 2834 | 1292 | 3.23 / 213.05 | 2 | 2 |
5 | 13 | 859.28 | 35 | 13.58 | 1578 | 750 | 3.98 / 213.80 | 2 | 4 |
6 | 8 | 0.24 | 190 | 14.12 | 340 | 912 | 4.90 / 214.71 | 2 | 16 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.52 | 30 | 14.46 | 478 | 207 | 0.21 / 205.43 | 2 | 2 |
2 | 7 | 2010.20 | 42 | 12.93 | 3111 | 1689 | 1.90 / 207.12 | 2 | 2 |
3 | 13 | 1611.60 | 35 | 13.16 | 2576 | 1187 | 3.08 / 208.31 | 2 | 2 |
4 | 13 | 632.52 | 35 | 13.74 | 1249 | 601 | 3.68 / 208.91 | 2 | 4 |
5 | 8 | -0.08 | 190 | 14.12 | 338 | 907 | 4.59 / 209.81 | 2 | 11 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.64 | 28 | 14.38 | 494 | 199 | 0.20 / 200.82 | 2 | 2 |
2 | 10 | 1002.64 | 3 | 14.30 | 1800 | 77 | 0.28 / 200.89 | 2 | 2 |
3 | 7 | 2005.32 | 42 | 12.96 | 3102 | 1688 | 1.96 / 202.58 | 2 | 2 |
4 | 13 | 1597.44 | 35 | 13.19 | 2528 | 1167 | 3.13 / 203.75 | 2 | 2 |
5 | 13 | 670.04 | 35 | 13.75 | 1302 | 627 | 3.76 / 204.37 | 2 | 4 |
6 | 8 | 0.04 | 190 | 14.27 | 313 | 849 | 4.61 / 205.22 | 2 | 16 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.08 | 29 | 14.41 | 490 | 205 | 0.20 / 196.13 | 2 | 2 |
2 | 3 | 956.92 | -1 | 14.41 | 490 | 0 | 0.00 / 196.13 | 2 | 2 |
3 | 7 | 2002.64 | 42 | 12.94 | 3112 | 1691 | 1.90 / 197.82 | 2 | 2 |
4 | 13 | 1810.60 | 35 | 13.04 | 2859 | 1305 | 3.20 / 199.13 | 2 | 2 |
5 | 13 | 622.64 | 35 | 13.77 | 1234 | 595 | 3.80 / 199.72 | 2 | 4 |
6 | 8 | 0.24 | 190 | 14.16 | 332 | 893 | 4.69 / 200.62 | 2 | 11 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.12 | 29 | 14.48 | 487 | 205 | 0.20 / 191.46 | 2 | 2 |
2 | 7 | 2002.24 | 42 | 12.97 | 3111 | 1695 | 1.90 / 193.15 | 2 | 2 |
3 | 13 | 1806.32 | 35 | 13.06 | 2844 | 1300 | 3.20 / 194.45 | 2 | 2 |
4 | 13 | 588.84 | 35 | 13.80 | 1188 | 574 | 3.77 / 195.03 | 2 | 4 |
5 | 8 | -0.04 | 190 | 14.17 | 334 | 899 | 4.67 / 195.93 | 2 | 25 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.56 | 29 | 14.47 | 506 | 212 | 0.21 / 186.62 | 2 | 2 |
2 | 7 | 2019.52 | 43 | 12.95 | 3127 | 1741 | 1.95 / 188.37 | 2 | 2 |
3 | 13 | 1819.96 | 35 | 13.07 | 2870 | 1313 | 3.27 / 189.68 | 2 | 2 |
4 | 13 | 499.08 | 35 | 13.88 | 1079 | 524 | 3.79 / 190.20 | 2 | 4 |
5 | 13 | 4.40 | 35 | 14.41 | 345 | 174 | 3.96 / 190.38 | 2 | 5 |
6 | 8 | 0.04 | 190 | 14.18 | 326 | 878 | 4.84 / 191.26 | 2 | 15 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.72 | 29 | 14.50 | 470 | 198 | 0.20 / 181.90 | 2 | 2 |
2 | 7 | 2007.20 | 43 | 12.95 | 3115 | 1735 | 1.93 / 183.64 | 2 | 2 |
3 | 13 | 1811.24 | 35 | 13.08 | 2847 | 1303 | 3.24 / 184.94 | 2 | 2 |
4 | 13 | 578.12 | 35 | 13.82 | 1196 | 579 | 3.81 / 185.52 | 2 | 4 |
5 | 8 | 0.12 | 190 | 14.21 | 331 | 894 | 4.71 / 186.41 | 2 | 14 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.52 | 28 | 14.52 | 464 | 189 | 0.19 / 177.35 | 2 | 2 |
2 | 3 | 1034.76 | 1 | 14.22 | 1856 | 26 | 0.22 / 177.37 | 2 | 2 |
3 | 7 | 2036.24 | 43 | 12.95 | 3161 | 1760 | 1.98 / 179.13 | 2 | 2 |
4 | 13 | 1457.72 | 35 | 13.29 | 2398 | 1115 | 3.09 / 180.25 | 2 | 2 |
5 | 13 | 573.36 | 35 | 13.85 | 1180 | 572 | 3.66 / 180.82 | 2 | 4 |
6 | 8 | -0.04 | 190 | 14.25 | 326 | 883 | 4.55 / 181.70 | 2 | 10 |
Average= | 4.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.56 | 29 | 14.54 | 468 | 197 | 0.20 / 173.07 | 2 | 2 |
2 | 3 | 972.40 | -1 | 14.54 | 468 | 0 | 0.00 / 173.07 | 2 | 2 |
3 | 7 | 1870.04 | 42 | 13.07 | 2934 | 1611 | 1.81 / 174.68 | 2 | 2 |
4 | 13 | 1283.12 | 35 | 13.37 | 2165 | 1013 | 2.82 / 175.69 | 2 | 3 |
5 | 13 | 616.20 | 35 | 13.83 | 1241 | 601 | 3.42 / 176.29 | 2 | 4 |
6 | 8 | 0.00 | 190 | 14.26 | 320 | 867 | 4.29 / 177.16 | 2 | 15 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.60 | 29 | 14.56 | 482 | 204 | 0.20 / 168.50 | 2 | 2 |
2 | 7 | 2004.56 | 42 | 13.00 | 3114 | 1700 | 1.90 / 170.20 | 2 | 2 |
3 | 13 | 1577.52 | 35 | 13.25 | 2544 | 1180 | 3.08 / 171.38 | 2 | 2 |
4 | 13 | 661.92 | 35 | 13.80 | 1303 | 629 | 3.71 / 172.01 | 2 | 4 |
5 | 8 | 0.04 | 190 | 14.26 | 319 | 864 | 4.58 / 172.87 | 2 | 12 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.80 | 29 | 14.58 | 457 | 193 | 0.19 / 163.93 | 2 | 2 |
2 | 7 | 1907.96 | 42 | 13.06 | 2968 | 1628 | 1.82 / 165.55 | 2 | 2 |
3 | 13 | 1511.20 | 35 | 13.29 | 2453 | 1141 | 2.96 / 166.69 | 2 | 2 |
4 | 13 | 553.00 | 35 | 13.90 | 1149 | 559 | 3.52 / 167.25 | 2 | 4 |
5 | 13 | 21.60 | 35 | 14.46 | 362 | 183 | 3.70 / 167.44 | 2 | 5 |
6 | 8 | -0.16 | 190 | 14.27 | 316 | 857 | 4.56 / 168.29 | 2 | 20 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.28 | 30 | 14.58 | 457 | 200 | 0.20 / 159.50 | 2 | 2 |
2 | 3 | 948.16 | -1 | 14.58 | 457 | 0 | 0.00 / 159.50 | 2 | 2 |
3 | 7 | 2003.28 | 42 | 13.03 | 3108 | 1701 | 1.90 / 161.20 | 2 | 2 |
4 | 13 | 1441.60 | 35 | 13.33 | 2368 | 1105 | 3.01 / 162.31 | 2 | 2 |
5 | 13 | 545.72 | 35 | 13.92 | 1144 | 557 | 3.56 / 162.87 | 2 | 4 |
6 | 8 | 0.20 | 190 | 14.30 | 319 | 867 | 4.43 / 163.73 | 2 | 18 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.56 | 30 | 14.66 | 449 | 197 | 0.20 / 154.90 | 2 | 2 |
2 | 7 | 2005.44 | 42 | 13.02 | 3114 | 1703 | 1.90 / 156.60 | 2 | 2 |
3 | 13 | 1606.08 | 35 | 13.28 | 2578 | 1198 | 3.10 / 157.80 | 2 | 2 |
4 | 13 | 690.84 | 35 | 13.83 | 1337 | 647 | 3.75 / 158.44 | 2 | 4 |
5 | 8 | -0.08 | 190 | 14.34 | 315 | 858 | 4.60 / 159.30 | 2 | 12 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.64 | 30 | 14.68 | 444 | 196 | 0.20 / 150.35 | 2 | 2 |
2 | 7 | 2002.88 | 42 | 13.06 | 3105 | 1703 | 1.90 / 152.05 | 2 | 2 |
3 | 13 | 1590.92 | 35 | 13.31 | 2573 | 1199 | 3.10 / 153.25 | 2 | 2 |
4 | 13 | 662.88 | 35 | 13.95 | 1280 | 625 | 3.72 / 153.88 | 2 | 3 |
5 | 8 | 0.08 | 190 | 14.44 | 299 | 820 | 4.54 / 154.70 | 2 | 11 |
Average= | 4.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.96 | 30 | 14.69 | 448 | 197 | 0.20 / 145.81 | 2 | 2 |
2 | 7 | 2002.44 | 42 | 13.07 | 3131 | 1719 | 1.92 / 147.53 | 2 | 2 |
3 | 13 | 1572.88 | 35 | 13.33 | 2549 | 1189 | 3.11 / 148.72 | 2 | 2 |
4 | 13 | 654.72 | 35 | 13.98 | 1266 | 619 | 3.72 / 149.34 | 2 | 3 |
5 | 8 | 0.44 | 190 | 14.46 | 298 | 819 | 4.54 / 150.16 | 2 | 13 |
Average= | 4.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.96 | 30 | 14.68 | 444 | 196 | 0.20 / 141.16 | 2 | 2 |
2 | 7 | 2007.32 | 42 | 13.07 | 3128 | 1717 | 1.91 / 142.88 | 2 | 2 |
3 | 13 | 1610.68 | 35 | 13.33 | 2605 | 1215 | 3.13 / 144.10 | 2 | 2 |
4 | 13 | 532.32 | 35 | 14.11 | 1099 | 543 | 3.67 / 144.64 | 2 | 2 |
5 | 13 | 7.32 | 35 | 14.67 | 322 | 165 | 3.84 / 144.80 | 2 | 2 |
6 | 8 | -0.16 | 190 | 14.43 | 295 | 809 | 4.64 / 145.61 | 2 | 14 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.12 | 30 | 14.69 | 441 | 194 | 0.19 / 136.52 | 2 | 2 |
2 | 7 | 2005.96 | 42 | 13.07 | 3109 | 1707 | 1.90 / 138.23 | 2 | 2 |
3 | 13 | 1606.44 | 33 | 13.34 | 2587 | 1139 | 3.04 / 139.37 | 2 | 2 |
4 | 13 | 714.96 | 33 | 13.96 | 1359 | 626 | 3.67 / 139.99 | 2 | 3 |
5 | 13 | 15.76 | 33 | 14.66 | 330 | 160 | 3.83 / 140.15 | 2 | 2 |
6 | 8 | -0.04 | 190 | 14.42 | 298 | 816 | 4.64 / 140.97 | 2 | 12 |
Average= | 4.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.84 | 30 | 14.69 | 446 | 197 | 0.20 / 131.85 | 2 | 2 |
2 | 7 | 2009.84 | 43 | 13.03 | 3129 | 1753 | 1.95 / 133.60 | 2 | 2 |
3 | 13 | 1597.20 | 33 | 13.35 | 2561 | 1128 | 3.08 / 134.73 | 2 | 2 |
4 | 13 | 701.88 | 33 | 13.96 | 1336 | 615 | 3.69 / 135.35 | 2 | 3 |
5 | 13 | 15.28 | 33 | 14.66 | 332 | 161 | 3.85 / 135.51 | 2 | 2 |
6 | 8 | -0.12 | 190 | 14.41 | 299 | 819 | 4.67 / 136.33 | 2 | 11 |
Average= | 4.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.76 | 30 | 14.68 | 455 | 200 | 0.20 / 127.20 | 2 | 2 |
2 | 7 | 2003.16 | 42 | 13.05 | 3126 | 1713 | 1.91 / 128.92 | 2 | 2 |
3 | 13 | 1604.32 | 33 | 13.34 | 2580 | 1136 | 3.05 / 130.05 | 2 | 2 |
4 | 13 | 733.44 | 33 | 13.93 | 1388 | 638 | 3.69 / 130.69 | 2 | 3 |
5 | 13 | 5.72 | 33 | 14.68 | 314 | 152 | 3.84 / 130.84 | 2 | 3 |
6 | 8 | -0.12 | 190 | 14.43 | 295 | 809 | 4.65 / 131.65 | 2 | 14 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.76 | 30 | 14.67 | 459 | 202 | 0.20 / 122.73 | 2 | 2 |
2 | 7 | 2006.92 | 42 | 13.04 | 3105 | 1701 | 1.90 / 124.43 | 2 | 2 |
3 | 13 | 1600.00 | 33 | 13.33 | 2579 | 1134 | 3.04 / 125.57 | 2 | 2 |
4 | 13 | 671.00 | 33 | 13.99 | 1304 | 602 | 3.64 / 126.17 | 2 | 3 |
5 | 8 | 0.20 | 190 | 14.47 | 304 | 836 | 4.47 / 127.00 | 2 | 10 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.36 | 29 | 14.68 | 448 | 191 | 0.19 / 118.21 | 2 | 2 |
2 | 7 | 2003.12 | 43 | 13.02 | 3114 | 1743 | 1.93 / 119.95 | 2 | 2 |
3 | 13 | 1606.48 | 33 | 13.34 | 2578 | 1135 | 3.07 / 121.08 | 2 | 2 |
4 | 13 | 691.88 | 33 | 13.97 | 1334 | 615 | 3.68 / 121.70 | 2 | 2 |
5 | 8 | -0.04 | 190 | 14.47 | 302 | 830 | 4.51 / 122.53 | 2 | 10 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.52 | 29 | 14.69 | 448 | 191 | 0.19 / 113.76 | 2 | 2 |
2 | 7 | 2003.72 | 42 | 13.01 | 3124 | 1707 | 1.90 / 115.47 | 2 | 2 |
3 | 13 | 1585.44 | 33 | 13.34 | 2554 | 1124 | 3.02 / 116.59 | 2 | 2 |
4 | 13 | 686.08 | 33 | 13.99 | 1311 | 605 | 3.63 / 117.20 | 2 | 3 |
5 | 8 | 0.12 | 190 | 14.48 | 298 | 820 | 4.45 / 118.02 | 2 | 10 |
Average= | 4.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.12 | 29 | 14.68 | 454 | 193 | 0.19 / 109.27 | 2 | 2 |
2 | 7 | 2006.24 | 42 | 13.03 | 3111 | 1703 | 1.90 / 110.97 | 2 | 2 |
3 | 13 | 1604.20 | 33 | 13.33 | 2579 | 1134 | 3.03 / 112.11 | 2 | 2 |
4 | 13 | 708.40 | 33 | 13.96 | 1353 | 623 | 3.65 / 112.73 | 2 | 3 |
5 | 8 | 0.12 | 190 | 14.47 | 305 | 839 | 4.49 / 113.57 | 2 | 10 |
Average= | 4.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.44 | 29 | 14.67 | 458 | 195 | 0.19 / 104.79 | 2 | 2 |
2 | 7 | 2008.76 | 42 | 13.05 | 3119 | 1710 | 1.90 / 106.50 | 2 | 2 |
3 | 13 | 1599.80 | 33 | 13.34 | 2567 | 1130 | 3.03 / 107.63 | 2 | 2 |
4 | 13 | 706.00 | 33 | 13.97 | 1349 | 622 | 3.66 / 108.25 | 2 | 3 |
5 | 8 | 0.16 | 190 | 14.47 | 299 | 822 | 4.48 / 109.08 | 2 | 7 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.12 | 29 | 14.68 | 445 | 189 | 0.19 / 100.09 | 2 | 2 |
2 | 7 | 2002.08 | 42 | 13.07 | 3115 | 1710 | 1.90 / 101.80 | 2 | 2 |
3 | 13 | 1806.12 | 33 | 13.22 | 2847 | 1242 | 3.14 / 103.05 | 2 | 2 |
4 | 13 | 863.48 | 33 | 13.84 | 1569 | 717 | 3.86 / 103.76 | 2 | 3 |
5 | 8 | 0.20 | 190 | 14.47 | 304 | 836 | 4.69 / 104.60 | 2 | 9 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.12 | 29 | 14.68 | 453 | 193 | 0.19 / 95.60 | 2 | 2 |
2 | 7 | 2006.52 | 42 | 13.07 | 3109 | 1707 | 1.90 / 97.31 | 2 | 2 |
3 | 13 | 1631.64 | 33 | 13.33 | 2607 | 1147 | 3.05 / 98.46 | 2 | 2 |
4 | 13 | 715.24 | 33 | 13.97 | 1359 | 627 | 3.67 / 99.08 | 2 | 3 |
5 | 8 | 0.04 | 190 | 14.48 | 298 | 820 | 4.49 / 99.90 | 2 | 12 |
Average= | 4.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.36 | 29 | 14.68 | 459 | 195 | 0.20 / 91.15 | 2 | 2 |
2 | 7 | 2000.72 | 42 | 13.06 | 3120 | 1711 | 1.91 / 92.86 | 2 | 2 |
3 | 13 | 1580.76 | 33 | 13.36 | 2544 | 1122 | 3.03 / 93.99 | 2 | 2 |
4 | 13 | 660.44 | 33 | 13.99 | 1289 | 595 | 3.62 / 94.58 | 2 | 3 |
5 | 8 | 0.12 | 190 | 14.47 | 302 | 830 | 4.45 / 95.41 | 2 | 14 |
Average= | 4.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.56 | 29 | 14.67 | 449 | 191 | 0.19 / 86.69 | 2 | 2 |
2 | 7 | 2005.08 | 42 | 13.11 | 3122 | 1719 | 1.91 / 88.41 | 2 | 2 |
3 | 13 | 1582.80 | 33 | 13.38 | 2546 | 1124 | 3.03 / 89.53 | 2 | 2 |
4 | 13 | 668.44 | 33 | 14.01 | 1296 | 599 | 3.63 / 90.13 | 2 | 3 |
5 | 8 | -0.04 | 190 | 14.49 | 301 | 829 | 4.46 / 90.96 | 2 | 11 |
Average= | 4.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.44 | 29 | 14.62 | 465 | 197 | 0.20 / 82.35 | 2 | 2 |
2 | 7 | 2008.16 | 43 | 13.08 | 3127 | 1759 | 1.96 / 84.11 | 2 | 2 |
3 | 13 | 1397.16 | 33 | 13.48 | 2319 | 1032 | 2.99 / 85.14 | 2 | 2 |
4 | 13 | 528.28 | 33 | 14.11 | 1106 | 515 | 3.50 / 85.66 | 2 | 4 |
5 | 8 | 0.12 | 190 | 14.44 | 305 | 837 | 4.34 / 86.50 | 2 | 11 |
Average= | 4.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.40 | 28 | 14.64 | 469 | 192 | 0.19 / 77.81 | 2 | 2 |
2 | 7 | 2001.44 | 43 | 13.11 | 3108 | 1752 | 1.94 / 79.56 | 2 | 2 |
3 | 13 | 1567.60 | 33 | 13.40 | 2528 | 1118 | 3.06 / 80.68 | 2 | 2 |
4 | 13 | 654.44 | 33 | 13.98 | 1293 | 597 | 3.66 / 81.28 | 2 | 5 |
5 | 8 | 0.04 | 190 | 14.39 | 322 | 880 | 4.54 / 82.16 | 2 | 11 |
Average= | 4.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.12 | 28 | 14.66 | 465 | 191 | 0.19 / 73.40 | 2 | 2 |
2 | 7 | 2004.60 | 42 | 13.14 | 3089 | 1705 | 1.90 / 75.10 | 2 | 2 |
3 | 13 | 1417.04 | 32 | 13.52 | 2329 | 1008 | 2.90 / 76.11 | 2 | 2 |
4 | 13 | 738.12 | 32 | 13.95 | 1411 | 630 | 3.53 / 76.74 | 2 | 4 |
5 | 8 | 0.20 | 190 | 14.40 | 321 | 878 | 4.41 / 77.62 | 2 | 20 |
Average= | 4.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.28 | 28 | 14.63 | 474 | 194 | 0.19 / 68.92 | 2 | 2 |
2 | 7 | 2001.56 | 42 | 13.15 | 3137 | 1733 | 1.93 / 70.66 | 2 | 2 |
3 | 13 | 1389.48 | 32 | 13.54 | 2308 | 1000 | 2.93 / 71.66 | 2 | 2 |
4 | 13 | 510.92 | 32 | 14.13 | 1096 | 496 | 3.42 / 72.15 | 2 | 4 |
5 | 13 | 3.56 | 32 | 14.65 | 351 | 165 | 3.59 / 72.32 | 2 | 2 |
6 | 8 | -0.20 | 190 | 14.32 | 327 | 890 | 4.48 / 73.21 | 2 | 15 |
Average= | 4.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.36 | 27 | 14.61 | 489 | 193 | 0.19 / 64.39 | 2 | 2 |
2 | 7 | 2005.08 | 42 | 13.17 | 3114 | 1722 | 1.92 / 66.11 | 2 | 2 |
3 | 13 | 1593.12 | 32 | 13.43 | 2578 | 1108 | 3.02 / 67.22 | 2 | 2 |
4 | 13 | 682.68 | 32 | 13.98 | 1345 | 602 | 3.62 / 67.82 | 2 | 4 |
5 | 8 | 0.24 | 190 | 14.37 | 333 | 909 | 4.53 / 68.73 | 2 | 12 |
Average= | 4.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.96 | 27 | 14.62 | 493 | 195 | 0.19 / 59.86 | 2 | 2 |
2 | 7 | 2003.64 | 43 | 13.17 | 3125 | 1770 | 1.96 / 61.63 | 2 | 2 |
3 | 13 | 1402.76 | 32 | 13.53 | 2334 | 1011 | 2.97 / 62.64 | 2 | 2 |
4 | 13 | 714.12 | 32 | 13.97 | 1390 | 621 | 3.60 / 63.27 | 2 | 5 |
5 | 8 | 0.08 | 190 | 14.35 | 341 | 930 | 4.53 / 64.19 | 2 | 20 |
Average= | 4.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.16 | 27 | 14.64 | 503 | 199 | 0.20 / 55.14 | 2 | 2 |
2 | 7 | 2003.48 | 42 | 13.19 | 3123 | 1730 | 1.93 / 56.87 | 2 | 2 |
3 | 13 | 1582.40 | 32 | 13.45 | 2562 | 1103 | 3.03 / 57.98 | 2 | 2 |
4 | 13 | 666.36 | 32 | 14.00 | 1324 | 593 | 3.62 / 58.57 | 2 | 5 |
5 | 13 | 25.20 | 32 | 14.62 | 396 | 185 | 3.81 / 58.76 | 2 | 5 |
6 | 8 | -0.24 | 190 | 14.31 | 336 | 914 | 4.72 / 59.67 | 2 | 16 |
Average= | 3.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.20 | 27 | 14.62 | 495 | 195 | 0.20 / 50.46 | 2 | 2 |
2 | 7 | 2002.72 | 42 | 13.19 | 3123 | 1730 | 1.93 / 52.19 | 2 | 2 |
3 | 13 | 1388.92 | 32 | 13.54 | 2325 | 1007 | 2.93 / 53.19 | 2 | 2 |
4 | 13 | 689.36 | 32 | 13.97 | 1368 | 612 | 3.54 / 53.80 | 2 | 5 |
5 | 13 | 36.48 | 32 | 14.61 | 422 | 197 | 3.74 / 54.00 | 2 | 5 |
6 | 8 | -0.08 | 190 | 14.31 | 347 | 943 | 4.69 / 54.95 | 2 | 17 |
Average= | 3.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.08 | 29 | 14.65 | 475 | 202 | 0.20 / 46.09 | 2 | 2 |
2 | 3 | 942.40 | -1 | 14.65 | 475 | 0 | 0.00 / 46.09 | 2 | 2 |
3 | 7 | 2003.44 | 42 | 13.17 | 3148 | 1741 | 1.94 / 47.83 | 2 | 2 |
4 | 13 | 1396.68 | 32 | 13.53 | 2325 | 1007 | 2.95 / 48.84 | 2 | 2 |
5 | 13 | 504.12 | 32 | 14.12 | 1101 | 497 | 3.45 / 49.34 | 2 | 5 |
6 | 8 | 0.32 | 190 | 14.36 | 339 | 925 | 4.37 / 50.26 | 2 | 15 |
Average= | 3.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.88 | 29 | 14.72 | 470 | 201 | 0.20 / 41.72 | 2 | 2 |
2 | 7 | 2002.80 | 42 | 13.18 | 3141 | 1739 | 1.94 / 43.45 | 2 | 2 |
3 | 13 | 1409.92 | 32 | 13.53 | 2341 | 1014 | 2.95 / 44.47 | 2 | 2 |
4 | 13 | 524.40 | 32 | 14.10 | 1125 | 508 | 3.46 / 44.98 | 2 | 5 |
5 | 8 | -0.08 | 190 | 14.38 | 334 | 913 | 4.37 / 45.89 | 2 | 15 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.80 | 27 | 14.80 | 445 | 178 | 0.18 / 37.12 | 2 | 2 |
2 | 3 | 1045.04 | 1 | 14.62 | 1859 | 27 | 0.21 / 37.15 | 2 | 2 |
3 | 7 | 2003.44 | 43 | 13.15 | 3129 | 1769 | 1.97 / 38.92 | 2 | 2 |
4 | 13 | 1583.60 | 32 | 13.44 | 2600 | 1118 | 3.09 / 40.04 | 2 | 2 |
5 | 13 | 661.32 | 32 | 14.02 | 1315 | 590 | 3.68 / 40.63 | 2 | 4 |
6 | 8 | -0.08 | 190 | 14.47 | 323 | 888 | 4.57 / 41.51 | 2 | 11 |
Average= | 3.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.36 | 27 | 14.72 | 437 | 174 | 0.17 / 32.80 | 2 | 2 |
2 | 7 | 2003.32 | 42 | 13.22 | 3081 | 1711 | 1.88 / 34.51 | 2 | 2 |
3 | 13 | 1413.56 | 32 | 13.54 | 2302 | 997 | 2.88 / 35.51 | 2 | 2 |
4 | 13 | 733.48 | 32 | 13.99 | 1391 | 623 | 3.50 / 36.13 | 2 | 4 |
5 | 8 | 0.08 | 190 | 14.55 | 294 | 813 | 4.32 / 36.94 | 2 | 7 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.12 | 26 | 14.72 | 433 | 166 | 0.17 / 28.53 | 2 | 2 |
2 | 3 | 1030.40 | 1 | 14.59 | 1821 | 27 | 0.19 / 28.56 | 2 | 2 |
3 | 7 | 2001.24 | 42 | 13.22 | 3051 | 1694 | 1.89 / 30.25 | 2 | 2 |
4 | 13 | 1395.24 | 32 | 13.52 | 2264 | 979 | 2.87 / 31.23 | 2 | 2 |
5 | 13 | 723.84 | 32 | 13.95 | 1346 | 601 | 3.47 / 31.83 | 2 | 4 |
6 | 8 | 0.00 | 190 | 14.44 | 290 | 796 | 4.26 / 32.63 | 2 | 12 |
Average= | 3.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.92 | 26 | 14.72 | 424 | 162 | 0.16 / 24.42 | 2 | 2 |
2 | 3 | 1019.92 | 1 | 14.54 | 1810 | 26 | 0.19 / 24.44 | 2 | 2 |
3 | 7 | 2003.24 | 42 | 13.20 | 3058 | 1695 | 1.88 / 26.14 | 2 | 2 |
4 | 13 | 1395.28 | 32 | 13.50 | 2258 | 975 | 2.86 / 27.11 | 2 | 3 |
5 | 13 | 494.76 | 32 | 14.14 | 1025 | 464 | 3.32 / 27.58 | 2 | 4 |
6 | 8 | 0.00 | 190 | 14.43 | 287 | 787 | 4.11 / 28.36 | 2 | 17 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.64 | 25 | 14.69 | 435 | 160 | 0.16 / 20.01 | 2 | 2 |
2 | 3 | 1019.56 | 1 | 14.51 | 1810 | 26 | 0.19 / 20.03 | 2 | 2 |
3 | 7 | 2002.32 | 74 | 12.93 | 3041 | 2910 | 3.10 / 22.94 | 2 | 2 |
4 | 13 | 594.16 | 25 | 14.08 | 1172 | 413 | 3.51 / 23.36 | 2 | 4 |
5 | 13 | 16.84 | 25 | 14.72 | 321 | 118 | 3.63 / 23.47 | 2 | 4 |
6 | 8 | 0.04 | 190 | 14.36 | 286 | 780 | 4.41 / 24.25 | 2 | 13 |
Average= | 3.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.00 | 25 | 14.75 | 425 | 157 | 0.16 / 15.60 | 2 | 2 |
2 | 7 | 1981.64 | 75 | 12.89 | 2997 | 2897 | 3.05 / 18.50 | 2 | 2 |
3 | 13 | 723.00 | 25 | 13.97 | 1340 | 468 | 3.52 / 18.96 | 2 | 4 |
4 | 13 | 12.56 | 25 | 14.71 | 308 | 113 | 3.64 / 19.08 | 2 | 6 |
5 | 8 | 0.12 | 190 | 14.35 | 283 | 772 | 4.41 / 19.85 | 2 | 19 |
Average= | 3.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.96 | 25 | 14.73 | 411 | 151 | 0.15 / 11.84 | 2 | 2 |
2 | 7 | 1510.00 | 75 | 13.12 | 2391 | 2353 | 2.50 / 14.19 | 2 | 2 |
3 | 13 | 546.44 | 25 | 14.08 | 1102 | 388 | 2.89 / 14.58 | 2 | 4 |
4 | 13 | 22.64 | 25 | 14.71 | 315 | 116 | 3.01 / 14.70 | 2 | 4 |
5 | 8 | -0.08 | 190 | 14.40 | 272 | 744 | 3.75 / 15.44 | 2 | 13 |
Average= | 3.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.52 | 25 | 14.70 | 405 | 149 | 0.15 / 8.02 | 2 | 2 |
2 | 7 | 1514.68 | 75 | 13.04 | 2400 | 2347 | 2.50 / 10.37 | 2 | 2 |
3 | 13 | 359.00 | 25 | 14.23 | 826 | 294 | 2.79 / 10.67 | 2 | 4 |
4 | 13 | 13.72 | 25 | 14.71 | 296 | 109 | 2.90 / 10.77 | 2 | 3 |
5 | 8 | -0.08 | 240 | 14.33 | 266 | 915 | 3.81 / 11.69 | 2 | 27 |
Average= | 2.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.36 | 25 | 14.65 | 410 | 150 | 0.15 / 4.24 | 2 | 2 |
2 | 7 | 1509.68 | 75 | 12.89 | 2388 | 2309 | 2.46 / 6.55 | 2 | 2 |
3 | 13 | 385.64 | 25 | 14.15 | 863 | 305 | 2.76 / 6.85 | 2 | 4 |
4 | 13 | 29.08 | 25 | 14.63 | 318 | 116 | 2.88 / 6.97 | 2 | 3 |
5 | 8 | -0.04 | 240 | 14.32 | 264 | 907 | 3.79 / 7.88 | 2 | 25 |
Average= | 2.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.72 | 25 | 14.72 | 387 | 142 | 0.14 / 1.52 | 2 | 2 |
2 | 7 | 997.56 | 74 | 13.06 | 1699 | 1642 | 1.78 / 3.16 | 2 | 3 |
3 | 8 | -0.08 | 240 | 14.27 | 270 | 925 | 2.71 / 4.09 | 2 | 19 |
Average= | 2.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.20 | 24 | 14.39 | 413 | 143 | 0.14 / 0.14 | 2 | 2 |
2 | 7 | 127.92 | 74 | 14.24 | 413 | 435 | 0.58 / 0.58 | 2 | 2 |
3 | 8 | 0.32 | 240 | 14.51 | 230 | 801 | 1.38 / 1.38 | 2 | 15 |
Average= | 1.38 (KJ/cycle) |