Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.52 | 81 | 14.10 | 362 | 413 | 0.41 / 1281.03 | 5 | 11 |
2 | 7 | 2007.92 | 106 | 9.02 | 1723 | 1647 | 2.06 / 1282.68 | 11 | 12 |
3 | 13 | 1939.72 | 36 | 12.82 | 1742 | 804 | 2.86 / 1283.48 | 4 | 34 |
4 | 13 | 1841.52 | 36 | 12.97 | 1680 | 784 | 3.65 / 1284.26 | 4 | 38 |
5 | 13 | 1314.04 | 36 | 13.31 | 1313 | 629 | 4.28 / 1284.89 | 4 | 46 |
6 | 13 | 792.44 | 36 | 13.55 | 947 | 462 | 4.74 / 1285.36 | 4 | 52 |
7 | 13 | 364.72 | 36 | 13.81 | 620 | 308 | 5.05 / 1285.66 | 4 | 54 |
8 | 8 | 0.12 | 450 | 14.16 | 283 | 1803 | 6.85 / 1287.47 | 5 | 70 |
Average= | 6.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.16 | 81 | 14.10 | 360 | 411 | 0.41 / 1274.20 | 5 | 12 |
2 | 7 | 2003.40 | 106 | 9.08 | 1723 | 1658 | 2.07 / 1275.86 | 12 | 13 |
3 | 13 | 1929.60 | 36 | 12.82 | 1726 | 797 | 2.87 / 1276.65 | 4 | 35 |
4 | 13 | 1732.24 | 36 | 13.06 | 1611 | 757 | 3.62 / 1277.41 | 4 | 39 |
5 | 13 | 1322.64 | 36 | 13.29 | 1326 | 634 | 4.26 / 1278.05 | 4 | 45 |
6 | 13 | 887.08 | 36 | 13.50 | 1018 | 495 | 4.75 / 1278.54 | 4 | 52 |
7 | 13 | 248.96 | 36 | 13.92 | 514 | 258 | 5.01 / 1278.80 | 5 | 52 |
8 | 8 | 0.04 | 450 | 14.16 | 285 | 1816 | 6.83 / 1280.61 | 5 | 71 |
Average= | 6.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.00 | 81 | 14.12 | 361 | 413 | 0.41 / 1267.41 | 5 | 12 |
2 | 7 | 2004.28 | 106 | 9.15 | 1726 | 1674 | 2.09 / 1269.08 | 12 | 14 |
3 | 13 | 1931.20 | 36 | 12.83 | 1736 | 802 | 2.89 / 1269.88 | 4 | 35 |
4 | 13 | 1834.48 | 36 | 12.97 | 1676 | 783 | 3.67 / 1270.67 | 4 | 38 |
5 | 13 | 1300.40 | 36 | 13.30 | 1308 | 626 | 4.30 / 1271.29 | 4 | 46 |
6 | 13 | 749.56 | 36 | 13.57 | 919 | 449 | 4.75 / 1271.74 | 4 | 53 |
7 | 13 | 231.72 | 36 | 13.93 | 498 | 250 | 5.00 / 1271.99 | 4 | 52 |
8 | 8 | 0.08 | 450 | 14.16 | 282 | 1797 | 6.79 / 1273.79 | 5 | 68 |
Average= | 6.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.52 | 81 | 14.09 | 368 | 420 | 0.42 / 1260.64 | 5 | 12 |
2 | 7 | 2003.92 | 105 | 9.09 | 1737 | 1658 | 2.08 / 1262.30 | 12 | 14 |
3 | 13 | 1931.68 | 36 | 12.84 | 1736 | 802 | 2.88 / 1263.10 | 4 | 35 |
4 | 13 | 1640.56 | 36 | 13.13 | 1552 | 734 | 3.61 / 1263.83 | 4 | 40 |
5 | 13 | 1239.40 | 36 | 13.33 | 1265 | 607 | 4.22 / 1264.44 | 4 | 47 |
6 | 13 | 915.64 | 36 | 13.48 | 1035 | 502 | 4.72 / 1264.94 | 4 | 52 |
7 | 13 | 164.12 | 36 | 14.00 | 443 | 223 | 4.95 / 1265.17 | 5 | 50 |
8 | 8 | 0.12 | 450 | 14.16 | 287 | 1829 | 6.78 / 1267.00 | 5 | 69 |
Average= | 6.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.88 | 81 | 14.10 | 362 | 413 | 0.41 / 1253.69 | 5 | 13 |
2 | 7 | 2003.96 | 105 | 9.25 | 1721 | 1672 | 2.08 / 1255.37 | 13 | 14 |
3 | 13 | 1934.84 | 36 | 12.84 | 1746 | 807 | 2.89 / 1256.17 | 4 | 35 |
4 | 13 | 1837.56 | 36 | 12.98 | 1681 | 785 | 3.68 / 1256.96 | 4 | 38 |
5 | 13 | 1304.56 | 36 | 13.30 | 1313 | 629 | 4.31 / 1257.59 | 4 | 45 |
6 | 13 | 777.48 | 36 | 13.55 | 946 | 461 | 4.77 / 1258.05 | 4 | 52 |
7 | 13 | 455.32 | 36 | 13.73 | 695 | 344 | 5.11 / 1258.39 | 4 | 55 |
8 | 8 | 0.08 | 450 | 14.15 | 287 | 1827 | 6.94 / 1260.22 | 5 | 65 |
Average= | 6.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.64 | 81 | 14.09 | 364 | 415 | 0.42 / 1246.76 | 5 | 13 |
2 | 7 | 2006.04 | 105 | 9.27 | 1733 | 1687 | 2.10 / 1248.45 | 13 | 15 |
3 | 13 | 1947.28 | 36 | 12.81 | 1750 | 807 | 2.91 / 1249.26 | 4 | 36 |
4 | 13 | 1855.56 | 36 | 12.97 | 1696 | 792 | 3.70 / 1250.05 | 4 | 37 |
5 | 13 | 1320.00 | 36 | 13.29 | 1321 | 632 | 4.33 / 1250.68 | 4 | 46 |
6 | 13 | 897.00 | 36 | 13.49 | 1028 | 499 | 4.83 / 1251.18 | 4 | 51 |
7 | 13 | 269.48 | 36 | 13.90 | 535 | 268 | 5.10 / 1251.45 | 4 | 53 |
8 | 8 | 0.04 | 450 | 14.14 | 288 | 1833 | 6.93 / 1253.28 | 5 | 68 |
Average= | 6.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.48 | 81 | 14.09 | 369 | 421 | 0.42 / 1239.99 | 5 | 12 |
2 | 7 | 2006.80 | 105 | 9.31 | 1727 | 1688 | 2.11 / 1241.68 | 12 | 15 |
3 | 13 | 1940.72 | 36 | 12.84 | 1746 | 807 | 2.92 / 1242.48 | 4 | 35 |
4 | 13 | 1848.20 | 36 | 12.98 | 1688 | 789 | 3.71 / 1243.27 | 4 | 39 |
5 | 13 | 1287.32 | 36 | 13.31 | 1303 | 624 | 4.33 / 1243.90 | 4 | 46 |
6 | 13 | 664.28 | 36 | 13.61 | 854 | 418 | 4.75 / 1244.32 | 4 | 54 |
7 | 13 | 156.04 | 36 | 14.01 | 433 | 218 | 4.97 / 1244.53 | 5 | 49 |
8 | 8 | 0.24 | 450 | 14.15 | 285 | 1815 | 6.78 / 1246.35 | 5 | 67 |
Average= | 6.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.00 | 81 | 14.10 | 362 | 413 | 0.41 / 1233.08 | 5 | 12 |
2 | 7 | 2009.36 | 105 | 9.32 | 1729 | 1692 | 2.11 / 1234.77 | 12 | 14 |
3 | 13 | 1924.60 | 36 | 12.85 | 1734 | 802 | 2.91 / 1235.57 | 4 | 37 |
4 | 13 | 1827.60 | 36 | 13.00 | 1667 | 780 | 3.69 / 1236.35 | 4 | 38 |
5 | 13 | 1408.36 | 36 | 13.25 | 1380 | 658 | 4.35 / 1237.01 | 4 | 46 |
6 | 13 | 863.40 | 36 | 13.51 | 1005 | 489 | 4.83 / 1237.50 | 4 | 52 |
7 | 13 | 217.32 | 36 | 13.96 | 487 | 245 | 5.08 / 1237.75 | 5 | 52 |
8 | 8 | 0.00 | 450 | 14.16 | 286 | 1822 | 6.90 / 1239.57 | 5 | 63 |
Average= | 6.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.76 | 81 | 14.10 | 359 | 410 | 0.41 / 1226.24 | 5 | 13 |
2 | 7 | 2005.04 | 105 | 9.33 | 1725 | 1690 | 2.10 / 1227.93 | 13 | 15 |
3 | 13 | 1929.24 | 36 | 12.85 | 1738 | 804 | 2.90 / 1228.74 | 4 | 36 |
4 | 13 | 1734.44 | 36 | 13.06 | 1614 | 759 | 3.66 / 1229.49 | 4 | 39 |
5 | 13 | 1418.56 | 36 | 13.25 | 1389 | 663 | 4.33 / 1230.16 | 4 | 45 |
6 | 13 | 762.72 | 36 | 13.56 | 930 | 454 | 4.78 / 1230.61 | 4 | 52 |
7 | 13 | 238.20 | 36 | 13.94 | 501 | 251 | 5.03 / 1230.86 | 5 | 51 |
8 | 8 | 0.20 | 450 | 14.16 | 283 | 1803 | 6.83 / 1232.67 | 5 | 64 |
Average= | 6.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.64 | 81 | 14.09 | 361 | 412 | 0.41 / 1219.39 | 5 | 14 |
2 | 7 | 2007.68 | 106 | 9.37 | 1726 | 1714 | 2.13 / 1221.10 | 14 | 15 |
3 | 13 | 1929.12 | 36 | 12.86 | 1738 | 805 | 2.93 / 1221.91 | 4 | 36 |
4 | 13 | 1833.96 | 36 | 13.00 | 1667 | 780 | 3.71 / 1222.69 | 4 | 38 |
5 | 13 | 1207.64 | 36 | 13.35 | 1243 | 597 | 4.31 / 1223.28 | 4 | 46 |
6 | 13 | 802.20 | 36 | 13.54 | 955 | 466 | 4.77 / 1223.75 | 4 | 53 |
7 | 13 | 270.92 | 36 | 13.90 | 536 | 268 | 5.04 / 1224.02 | 5 | 53 |
8 | 8 | 0.16 | 450 | 14.15 | 285 | 1815 | 6.86 / 1225.83 | 5 | 64 |
Average= | 6.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.12 | 81 | 14.10 | 365 | 417 | 0.42 / 1212.60 | 5 | 11 |
2 | 7 | 2003.92 | 105 | 9.43 | 1725 | 1708 | 2.12 / 1214.31 | 11 | 14 |
3 | 13 | 1922.52 | 36 | 12.86 | 1738 | 805 | 2.93 / 1215.11 | 4 | 35 |
4 | 13 | 1718.24 | 36 | 13.08 | 1595 | 751 | 3.68 / 1215.86 | 4 | 39 |
5 | 13 | 1296.68 | 36 | 13.30 | 1302 | 623 | 4.30 / 1216.49 | 4 | 45 |
6 | 13 | 673.04 | 36 | 13.60 | 864 | 423 | 4.73 / 1216.91 | 4 | 52 |
7 | 13 | 248.84 | 36 | 13.93 | 511 | 256 | 4.98 / 1217.17 | 5 | 50 |
8 | 8 | 0.12 | 450 | 14.16 | 284 | 1810 | 6.79 / 1218.97 | 5 | 71 |
Average= | 6.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.48 | 81 | 14.09 | 371 | 423 | 0.42 / 1205.72 | 5 | 13 |
2 | 7 | 2004.40 | 105 | 9.40 | 1727 | 1705 | 2.13 / 1207.43 | 13 | 15 |
3 | 13 | 1936.32 | 36 | 12.86 | 1746 | 808 | 2.94 / 1208.24 | 4 | 35 |
4 | 13 | 1847.40 | 36 | 12.99 | 1689 | 790 | 3.73 / 1209.03 | 4 | 38 |
5 | 13 | 1301.96 | 36 | 13.31 | 1307 | 626 | 4.35 / 1209.65 | 4 | 45 |
6 | 13 | 777.80 | 36 | 13.55 | 938 | 458 | 4.81 / 1210.11 | 4 | 52 |
7 | 13 | 244.72 | 36 | 13.94 | 508 | 255 | 5.06 / 1210.37 | 5 | 51 |
8 | 8 | 0.12 | 450 | 14.16 | 285 | 1816 | 6.88 / 1212.18 | 5 | 56 |
Average= | 6.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.00 | 81 | 14.10 | 369 | 421 | 0.42 / 1198.83 | 5 | 10 |
2 | 7 | 2015.72 | 106 | 9.46 | 1739 | 1744 | 2.17 / 1200.57 | 10 | 14 |
3 | 13 | 1929.56 | 36 | 12.88 | 1731 | 803 | 2.97 / 1201.38 | 4 | 35 |
4 | 13 | 1724.92 | 36 | 13.08 | 1603 | 755 | 3.72 / 1202.13 | 4 | 40 |
5 | 13 | 1209.28 | 36 | 13.35 | 1243 | 597 | 4.32 / 1202.73 | 4 | 45 |
6 | 13 | 788.48 | 36 | 13.55 | 945 | 461 | 4.78 / 1203.19 | 4 | 51 |
7 | 13 | 345.96 | 36 | 13.84 | 595 | 296 | 5.08 / 1203.49 | 4 | 52 |
8 | 8 | 0.16 | 450 | 14.16 | 285 | 1816 | 6.89 / 1205.30 | 5 | 69 |
Average= | 6.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.84 | 81 | 14.11 | 354 | 405 | 0.40 / 1191.91 | 5 | 10 |
2 | 7 | 2008.60 | 105 | 9.46 | 1727 | 1715 | 2.12 / 1193.63 | 10 | 15 |
3 | 13 | 1950.44 | 36 | 12.86 | 1756 | 813 | 2.93 / 1194.44 | 4 | 34 |
4 | 13 | 1867.16 | 36 | 12.97 | 1702 | 795 | 3.73 / 1195.24 | 4 | 38 |
5 | 13 | 1432.36 | 36 | 13.25 | 1401 | 668 | 4.40 / 1195.90 | 4 | 43 |
6 | 13 | 776.40 | 36 | 13.55 | 940 | 459 | 4.85 / 1196.36 | 4 | 52 |
7 | 13 | 150.08 | 36 | 14.06 | 424 | 215 | 5.07 / 1196.58 | 5 | 45 |
8 | 8 | 0.04 | 450 | 14.17 | 287 | 1830 | 6.90 / 1198.41 | 5 | 67 |
Average= | 6.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.44 | 81 | 14.12 | 367 | 420 | 0.42 / 1185.15 | 5 | 11 |
2 | 7 | 2003.76 | 105 | 9.55 | 1725 | 1730 | 2.15 / 1186.88 | 4 | 16 |
3 | 13 | 1936.56 | 36 | 12.86 | 1743 | 807 | 2.96 / 1187.69 | 4 | 36 |
4 | 13 | 1626.32 | 36 | 13.14 | 1536 | 727 | 3.68 / 1188.42 | 4 | 40 |
5 | 13 | 1205.36 | 36 | 13.35 | 1233 | 593 | 4.28 / 1189.01 | 4 | 46 |
6 | 13 | 777.84 | 36 | 13.55 | 941 | 459 | 4.73 / 1189.47 | 4 | 52 |
7 | 13 | 225.80 | 36 | 13.98 | 489 | 246 | 4.98 / 1189.72 | 5 | 48 |
8 | 8 | 0.08 | 450 | 14.18 | 281 | 1793 | 6.77 / 1191.51 | 5 | 58 |
Average= | 6.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.08 | 81 | 14.12 | 361 | 413 | 0.41 / 1178.34 | 5 | 11 |
2 | 7 | 2011.24 | 105 | 9.54 | 1735 | 1738 | 2.15 / 1180.08 | 11 | 16 |
3 | 13 | 1936.64 | 36 | 12.86 | 1731 | 801 | 2.95 / 1180.88 | 4 | 36 |
4 | 13 | 1838.28 | 36 | 13.00 | 1673 | 783 | 3.74 / 1181.66 | 4 | 38 |
5 | 13 | 1206.64 | 36 | 13.35 | 1243 | 597 | 4.33 / 1182.26 | 4 | 46 |
6 | 13 | 782.88 | 36 | 13.54 | 947 | 462 | 4.79 / 1182.72 | 4 | 52 |
7 | 13 | 143.60 | 36 | 14.07 | 418 | 212 | 5.01 / 1182.94 | 5 | 45 |
8 | 8 | 0.16 | 450 | 14.18 | 282 | 1799 | 6.81 / 1184.73 | 5 | 70 |
Average= | 6.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.28 | 81 | 14.13 | 356 | 407 | 0.41 / 1171.58 | 5 | 10 |
2 | 7 | 2003.88 | 105 | 9.59 | 1734 | 1746 | 2.15 / 1173.32 | 10 | 16 |
3 | 13 | 1928.28 | 36 | 12.87 | 1733 | 803 | 2.96 / 1174.13 | 4 | 35 |
4 | 13 | 1732.56 | 36 | 13.07 | 1611 | 758 | 3.71 / 1174.88 | 4 | 40 |
5 | 13 | 1199.20 | 36 | 13.34 | 1247 | 599 | 4.31 / 1175.48 | 4 | 46 |
6 | 13 | 784.32 | 36 | 13.54 | 946 | 461 | 4.77 / 1175.94 | 4 | 52 |
7 | 13 | 135.56 | 36 | 14.08 | 406 | 206 | 4.98 / 1176.15 | 5 | 45 |
8 | 8 | 0.20 | 450 | 14.18 | 279 | 1780 | 6.76 / 1177.93 | 5 | 61 |
Average= | 6.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.00 | 81 | 14.15 | 362 | 415 | 0.41 / 1164.83 | 5 | 10 |
2 | 7 | 2012.72 | 105 | 9.64 | 1735 | 1756 | 2.17 / 1166.59 | 10 | 16 |
3 | 13 | 1931.96 | 36 | 12.89 | 1738 | 807 | 2.98 / 1167.40 | 4 | 35 |
4 | 13 | 1722.76 | 36 | 13.08 | 1603 | 755 | 3.73 / 1168.15 | 4 | 40 |
5 | 13 | 1291.12 | 36 | 13.31 | 1303 | 624 | 4.36 / 1168.78 | 4 | 45 |
6 | 13 | 580.88 | 36 | 13.66 | 792 | 389 | 4.75 / 1169.17 | 4 | 52 |
7 | 13 | 79.08 | 36 | 14.13 | 365 | 186 | 4.93 / 1169.35 | 5 | 44 |
8 | 8 | -0.08 | 450 | 14.17 | 285 | 1817 | 6.75 / 1171.17 | 5 | 61 |
Average= | 6.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.28 | 81 | 14.13 | 362 | 414 | 0.41 / 1157.77 | 5 | 10 |
2 | 7 | 2011.72 | 105 | 9.63 | 1736 | 1755 | 2.17 / 1159.52 | 10 | 16 |
3 | 13 | 1938.72 | 36 | 12.89 | 1743 | 809 | 2.98 / 1160.33 | 4 | 34 |
4 | 13 | 1840.04 | 36 | 13.00 | 1681 | 787 | 3.77 / 1161.12 | 4 | 38 |
5 | 13 | 1385.36 | 36 | 13.27 | 1365 | 652 | 4.42 / 1161.77 | 4 | 45 |
6 | 13 | 716.12 | 36 | 13.59 | 894 | 437 | 4.85 / 1162.21 | 4 | 51 |
7 | 13 | 94.36 | 36 | 14.11 | 386 | 196 | 5.05 / 1162.41 | 5 | 44 |
8 | 13 | 54.48 | 36 | 14.15 | 349 | 178 | 5.23 / 1162.58 | 5 | 44 |
9 | 8 | 0.04 | 450 | 14.17 | 288 | 1836 | 7.06 / 1164.42 | 5 | 70 |
Average= | 6.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.68 | 81 | 14.15 | 359 | 411 | 0.41 / 1150.81 | 5 | 9 |
2 | 7 | 2005.64 | 105 | 9.68 | 1742 | 1771 | 2.18 / 1152.58 | 9 | 16 |
3 | 13 | 1929.60 | 36 | 12.87 | 1738 | 805 | 2.99 / 1153.38 | 4 | 36 |
4 | 13 | 1636.48 | 36 | 13.14 | 1547 | 732 | 3.72 / 1154.11 | 4 | 39 |
5 | 13 | 1192.44 | 36 | 13.35 | 1236 | 594 | 4.31 / 1154.71 | 4 | 45 |
6 | 13 | 753.80 | 36 | 13.56 | 921 | 450 | 4.76 / 1155.16 | 4 | 51 |
7 | 13 | 530.36 | 36 | 13.69 | 752 | 371 | 5.13 / 1155.53 | 4 | 54 |
8 | 8 | 0.04 | 450 | 14.15 | 287 | 1827 | 6.96 / 1157.35 | 5 | 63 |
Average= | 6.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.48 | 81 | 14.16 | 359 | 412 | 0.41 / 1143.89 | 5 | 10 |
2 | 7 | 2004.00 | 105 | 9.73 | 1734 | 1772 | 2.18 / 1145.66 | 4 | 16 |
3 | 13 | 1924.24 | 36 | 12.87 | 1733 | 803 | 2.99 / 1146.47 | 4 | 35 |
4 | 13 | 1827.88 | 36 | 13.01 | 1666 | 780 | 3.77 / 1147.25 | 4 | 38 |
5 | 13 | 1279.16 | 36 | 13.31 | 1292 | 619 | 4.39 / 1147.87 | 4 | 45 |
6 | 13 | 850.92 | 36 | 13.52 | 993 | 483 | 4.87 / 1148.35 | 4 | 51 |
7 | 13 | 179.28 | 36 | 14.01 | 455 | 229 | 5.10 / 1148.58 | 5 | 48 |
8 | 8 | 0.04 | 450 | 14.16 | 285 | 1816 | 6.91 / 1150.39 | 5 | 63 |
Average= | 6.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.72 | 81 | 14.15 | 359 | 411 | 0.41 / 1136.97 | 5 | 9 |
2 | 7 | 2009.64 | 105 | 9.74 | 1741 | 1781 | 2.19 / 1138.75 | 9 | 15 |
3 | 13 | 1938.80 | 36 | 12.88 | 1744 | 809 | 3.00 / 1139.56 | 4 | 35 |
4 | 13 | 1844.36 | 36 | 13.00 | 1683 | 788 | 3.79 / 1140.35 | 4 | 39 |
5 | 13 | 1393.88 | 36 | 13.26 | 1377 | 657 | 4.45 / 1141.00 | 4 | 44 |
6 | 13 | 713.32 | 36 | 13.57 | 898 | 439 | 4.88 / 1141.44 | 4 | 52 |
7 | 13 | 170.60 | 36 | 14.03 | 446 | 225 | 5.11 / 1141.67 | 5 | 48 |
8 | 8 | 0.28 | 450 | 14.18 | 284 | 1812 | 6.92 / 1143.48 | 5 | 60 |
Average= | 6.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.40 | 81 | 14.13 | 365 | 418 | 0.42 / 1129.97 | 5 | 9 |
2 | 7 | 2009.68 | 106 | 9.75 | 1733 | 1791 | 2.21 / 1131.76 | 4 | 16 |
3 | 13 | 1934.48 | 36 | 12.88 | 1746 | 810 | 3.02 / 1132.57 | 4 | 34 |
4 | 13 | 1629.96 | 36 | 13.14 | 1540 | 728 | 3.75 / 1133.30 | 4 | 41 |
5 | 13 | 1323.96 | 36 | 13.29 | 1329 | 636 | 4.38 / 1133.93 | 4 | 44 |
6 | 13 | 775.52 | 36 | 13.56 | 936 | 457 | 4.84 / 1134.39 | 4 | 52 |
7 | 13 | 70.88 | 36 | 14.15 | 363 | 185 | 5.02 / 1134.57 | 5 | 42 |
8 | 13 | 40.76 | 36 | 14.18 | 335 | 171 | 5.20 / 1134.74 | 5 | 43 |
9 | 8 | 0.04 | 450 | 14.19 | 284 | 1813 | 7.01 / 1136.56 | 5 | 65 |
Average= | 6.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.28 | 81 | 14.13 | 363 | 415 | 0.42 / 1123.00 | 5 | 9 |
2 | 7 | 2006.96 | 105 | 9.76 | 1746 | 1789 | 2.20 / 1124.79 | 9 | 17 |
3 | 13 | 1927.24 | 36 | 12.88 | 1735 | 804 | 3.01 / 1125.60 | 4 | 35 |
4 | 13 | 1637.36 | 36 | 13.13 | 1547 | 731 | 3.74 / 1126.33 | 4 | 41 |
5 | 13 | 1203.12 | 36 | 13.33 | 1248 | 599 | 4.34 / 1126.93 | 4 | 46 |
6 | 13 | 878.00 | 36 | 13.49 | 1016 | 493 | 4.83 / 1127.42 | 4 | 51 |
7 | 13 | 316.48 | 36 | 13.88 | 577 | 288 | 5.12 / 1127.71 | 4 | 52 |
8 | 8 | 0.00 | 450 | 14.14 | 289 | 1839 | 6.96 / 1129.55 | 5 | 73 |
Average= | 6.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.00 | 81 | 14.17 | 352 | 404 | 0.40 / 1116.01 | 5 | 9 |
2 | 7 | 2003.00 | 105 | 9.83 | 1733 | 1789 | 2.19 / 1117.80 | 9 | 16 |
3 | 13 | 1915.84 | 36 | 12.88 | 1729 | 802 | 2.99 / 1118.60 | 4 | 35 |
4 | 13 | 1720.48 | 36 | 13.09 | 1597 | 753 | 3.75 / 1119.35 | 4 | 39 |
5 | 13 | 1297.32 | 36 | 13.29 | 1313 | 628 | 4.38 / 1119.98 | 4 | 46 |
6 | 13 | 662.72 | 36 | 13.60 | 861 | 422 | 4.80 / 1120.40 | 4 | 53 |
7 | 13 | 74.88 | 36 | 14.13 | 368 | 187 | 4.98 / 1120.59 | 5 | 44 |
8 | 13 | 18.32 | 36 | 14.19 | 319 | 163 | 5.15 / 1120.75 | 5 | 44 |
9 | 8 | 0.04 | 450 | 14.14 | 289 | 1839 | 6.99 / 1122.59 | 5 | 66 |
Average= | 6.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.12 | 81 | 14.17 | 351 | 403 | 0.40 / 1109.10 | 5 | 10 |
2 | 7 | 2015.36 | 105 | 9.83 | 1746 | 1802 | 2.21 / 1110.90 | 4 | 17 |
3 | 13 | 1929.32 | 36 | 12.89 | 1742 | 808 | 3.01 / 1111.71 | 4 | 36 |
4 | 13 | 1725.04 | 36 | 13.09 | 1601 | 754 | 3.77 / 1112.46 | 4 | 40 |
5 | 13 | 1109.40 | 36 | 13.38 | 1179 | 568 | 4.34 / 1113.03 | 4 | 48 |
6 | 13 | 897.92 | 36 | 13.48 | 1025 | 497 | 4.83 / 1113.53 | 4 | 52 |
7 | 13 | 209.20 | 36 | 13.98 | 483 | 243 | 5.08 / 1113.77 | 5 | 51 |
8 | 8 | 0.04 | 450 | 14.17 | 287 | 1830 | 6.91 / 1115.60 | 5 | 62 |
Average= | 6.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.16 | 80 | 14.16 | 359 | 407 | 0.41 / 1102.10 | 5 | 11 |
2 | 3 | 1010.20 | 1 | 12.80 | 1128 | 14 | 0.42 / 1102.12 | 4 | 4 |
3 | 7 | 2004.92 | 106 | 9.84 | 1741 | 1816 | 2.24 / 1103.93 | 4 | 16 |
4 | 13 | 1925.64 | 36 | 12.88 | 1739 | 806 | 3.04 / 1104.74 | 4 | 35 |
5 | 13 | 1725.68 | 36 | 13.08 | 1611 | 759 | 3.80 / 1105.50 | 4 | 40 |
6 | 13 | 1099.84 | 36 | 13.39 | 1177 | 567 | 4.37 / 1106.06 | 4 | 46 |
7 | 13 | 685.32 | 36 | 13.60 | 869 | 425 | 4.79 / 1106.49 | 4 | 52 |
8 | 13 | 136.32 | 36 | 14.08 | 418 | 212 | 5.01 / 1106.70 | 5 | 45 |
9 | 13 | 24.08 | 36 | 14.19 | 326 | 167 | 5.17 / 1106.87 | 5 | 43 |
10 | 8 | 0.08 | 450 | 14.16 | 287 | 1829 | 7.00 / 1108.70 | 5 | 64 |
Average= | 6.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.60 | 80 | 14.15 | 355 | 402 | 0.40 / 1095.27 | 5 | 10 |
2 | 7 | 2012.08 | 105 | 9.88 | 1741 | 1806 | 2.21 / 1097.08 | 10 | 17 |
3 | 13 | 1923.24 | 36 | 12.88 | 1735 | 804 | 3.01 / 1097.88 | 4 | 35 |
4 | 13 | 1725.48 | 36 | 13.06 | 1605 | 755 | 3.77 / 1098.64 | 4 | 38 |
5 | 13 | 1190.28 | 36 | 13.34 | 1240 | 595 | 4.36 / 1099.23 | 4 | 47 |
6 | 13 | 769.40 | 36 | 13.54 | 937 | 457 | 4.82 / 1099.69 | 4 | 53 |
7 | 13 | 67.12 | 36 | 14.17 | 356 | 182 | 5.00 / 1099.87 | 5 | 43 |
8 | 8 | 0.04 | 450 | 14.18 | 286 | 1825 | 6.83 / 1101.69 | 5 | 67 |
Average= | 6.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.88 | 80 | 14.15 | 358 | 405 | 0.41 / 1088.21 | 5 | 10 |
2 | 7 | 2003.88 | 105 | 9.94 | 1740 | 1816 | 2.22 / 1090.03 | 10 | 18 |
3 | 13 | 1917.60 | 36 | 12.88 | 1726 | 800 | 3.02 / 1090.83 | 4 | 35 |
4 | 13 | 1726.40 | 36 | 13.08 | 1611 | 759 | 3.78 / 1091.59 | 4 | 38 |
5 | 13 | 1278.44 | 36 | 13.29 | 1297 | 621 | 4.40 / 1092.21 | 4 | 45 |
6 | 13 | 738.20 | 36 | 13.57 | 914 | 447 | 4.85 / 1092.65 | 4 | 52 |
7 | 13 | 188.72 | 36 | 14.01 | 467 | 236 | 5.08 / 1092.89 | 5 | 48 |
8 | 13 | 19.32 | 36 | 14.21 | 320 | 164 | 5.25 / 1093.05 | 5 | 46 |
9 | 8 | 0.04 | 450 | 14.17 | 285 | 1817 | 7.06 / 1094.87 | 5 | 69 |
Average= | 6.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.80 | 80 | 14.14 | 363 | 411 | 0.41 / 1081.21 | 5 | 10 |
2 | 7 | 2002.80 | 105 | 9.95 | 1739 | 1817 | 2.23 / 1083.03 | 4 | 17 |
3 | 13 | 1919.56 | 36 | 12.89 | 1730 | 803 | 3.03 / 1083.83 | 4 | 35 |
4 | 13 | 1624.20 | 36 | 13.14 | 1528 | 723 | 3.75 / 1084.56 | 4 | 39 |
5 | 13 | 1203.48 | 36 | 13.33 | 1243 | 596 | 4.35 / 1085.15 | 4 | 46 |
6 | 13 | 674.88 | 36 | 13.60 | 864 | 423 | 4.77 / 1085.58 | 4 | 53 |
7 | 13 | 248.12 | 36 | 13.95 | 511 | 257 | 5.03 / 1085.83 | 5 | 51 |
8 | 13 | 27.92 | 36 | 14.20 | 321 | 164 | 5.19 / 1086.00 | 5 | 47 |
9 | 8 | -0.04 | 450 | 14.15 | 284 | 1808 | 7.00 / 1087.80 | 5 | 65 |
Average= | 6.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.40 | 80 | 14.14 | 362 | 409 | 0.41 / 1074.20 | 5 | 10 |
2 | 7 | 2015.72 | 105 | 10.00 | 1745 | 1832 | 2.24 / 1076.04 | 10 | 18 |
3 | 13 | 1935.96 | 36 | 12.86 | 1740 | 806 | 3.05 / 1076.84 | 4 | 34 |
4 | 13 | 1634.28 | 36 | 13.13 | 1539 | 727 | 3.77 / 1077.57 | 4 | 39 |
5 | 13 | 1109.24 | 36 | 13.36 | 1185 | 570 | 4.34 / 1078.14 | 4 | 48 |
6 | 13 | 695.44 | 36 | 13.58 | 883 | 432 | 4.78 / 1078.57 | 4 | 53 |
7 | 13 | 147.84 | 36 | 14.04 | 432 | 218 | 4.99 / 1078.79 | 5 | 48 |
8 | 13 | 27.12 | 36 | 14.18 | 330 | 168 | 5.16 / 1078.96 | 5 | 47 |
9 | 8 | 0.08 | 450 | 14.14 | 290 | 1845 | 7.01 / 1080.80 | 5 | 69 |
Average= | 6.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.00 | 80 | 14.15 | 357 | 404 | 0.40 / 1067.51 | 5 | 10 |
2 | 7 | 2005.72 | 105 | 10.01 | 1744 | 1833 | 2.24 / 1069.34 | 10 | 18 |
3 | 13 | 1920.44 | 36 | 12.87 | 1737 | 805 | 3.04 / 1070.15 | 4 | 35 |
4 | 13 | 1519.40 | 36 | 13.18 | 1460 | 693 | 3.73 / 1070.84 | 4 | 40 |
5 | 13 | 1016.64 | 36 | 13.41 | 1112 | 537 | 4.27 / 1071.38 | 4 | 47 |
6 | 13 | 613.08 | 36 | 13.63 | 822 | 403 | 4.67 / 1071.78 | 4 | 53 |
7 | 13 | 46.48 | 36 | 14.16 | 344 | 175 | 4.85 / 1071.96 | 5 | 44 |
8 | 8 | 0.20 | 450 | 14.14 | 289 | 1839 | 6.69 / 1073.79 | 5 | 62 |
Average= | 6.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.00 | 80 | 14.14 | 364 | 412 | 0.41 / 1060.65 | 5 | 10 |
2 | 7 | 2008.44 | 105 | 10.08 | 1739 | 1841 | 2.25 / 1062.49 | 10 | 19 |
3 | 13 | 1927.80 | 36 | 12.87 | 1745 | 808 | 3.06 / 1063.30 | 4 | 36 |
4 | 13 | 1726.96 | 36 | 13.07 | 1607 | 756 | 3.82 / 1064.05 | 4 | 40 |
5 | 13 | 1290.52 | 36 | 13.28 | 1308 | 625 | 4.44 / 1064.68 | 4 | 45 |
6 | 13 | 651.88 | 36 | 13.61 | 851 | 417 | 4.86 / 1065.09 | 4 | 53 |
7 | 13 | 55.80 | 36 | 14.16 | 350 | 178 | 5.04 / 1065.27 | 5 | 46 |
8 | 8 | 0.08 | 450 | 14.14 | 288 | 1833 | 6.87 / 1067.11 | 5 | 65 |
Average= | 6.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.92 | 80 | 14.14 | 369 | 417 | 0.42 / 1053.79 | 5 | 10 |
2 | 7 | 2009.24 | 106 | 10.09 | 1744 | 1865 | 2.28 / 1055.66 | 10 | 18 |
3 | 13 | 1937.32 | 36 | 12.87 | 1744 | 808 | 3.09 / 1056.46 | 4 | 35 |
4 | 13 | 1531.84 | 36 | 13.17 | 1474 | 699 | 3.79 / 1057.16 | 4 | 41 |
5 | 13 | 1433.32 | 36 | 13.21 | 1398 | 665 | 4.45 / 1057.83 | 4 | 43 |
6 | 13 | 562.48 | 36 | 13.67 | 781 | 384 | 4.84 / 1058.21 | 4 | 53 |
7 | 13 | 71.60 | 36 | 14.14 | 364 | 185 | 5.02 / 1058.40 | 5 | 44 |
8 | 8 | 0.04 | 450 | 14.14 | 289 | 1839 | 6.86 / 1060.24 | 5 | 61 |
Average= | 6.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.24 | 80 | 14.13 | 363 | 410 | 0.41 / 1046.94 | 5 | 12 |
2 | 7 | 2012.92 | 105 | 10.11 | 1745 | 1852 | 2.26 / 1048.79 | 12 | 19 |
3 | 13 | 1924.20 | 36 | 12.88 | 1738 | 806 | 3.07 / 1049.60 | 4 | 34 |
4 | 13 | 1720.92 | 36 | 13.07 | 1605 | 755 | 3.82 / 1050.36 | 4 | 39 |
5 | 13 | 1094.60 | 36 | 13.38 | 1170 | 564 | 4.39 / 1050.92 | 4 | 47 |
6 | 13 | 688.76 | 36 | 13.59 | 874 | 428 | 4.81 / 1051.35 | 4 | 53 |
7 | 13 | 63.32 | 36 | 14.16 | 356 | 181 | 5.00 / 1051.53 | 5 | 46 |
8 | 8 | 0.04 | 450 | 14.13 | 290 | 1844 | 6.84 / 1053.37 | 5 | 68 |
Average= | 6.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.96 | 80 | 14.08 | 372 | 419 | 0.42 / 1039.92 | 5 | 13 |
2 | 7 | 2013.00 | 105 | 10.16 | 1749 | 1866 | 2.28 / 1041.78 | 13 | 17 |
3 | 13 | 1927.60 | 36 | 12.87 | 1738 | 805 | 3.09 / 1042.59 | 4 | 35 |
4 | 13 | 1622.28 | 36 | 13.12 | 1538 | 726 | 3.82 / 1043.32 | 4 | 41 |
5 | 13 | 1298.52 | 36 | 13.28 | 1310 | 626 | 4.44 / 1043.94 | 4 | 45 |
6 | 13 | 638.08 | 36 | 13.63 | 839 | 412 | 4.85 / 1044.35 | 4 | 52 |
7 | 13 | 47.48 | 36 | 14.17 | 346 | 177 | 5.03 / 1044.53 | 5 | 44 |
8 | 13 | 7.84 | 36 | 14.20 | 311 | 159 | 5.19 / 1044.69 | 5 | 48 |
9 | 8 | 0.00 | 450 | 14.12 | 290 | 1843 | 7.03 / 1046.53 | 5 | 62 |
Average= | 6.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.64 | 80 | 14.10 | 371 | 418 | 0.42 / 1032.98 | 5 | 14 |
2 | 7 | 2006.72 | 105 | 10.19 | 1746 | 1868 | 2.29 / 1034.85 | 14 | 19 |
3 | 13 | 1929.76 | 36 | 12.85 | 1751 | 810 | 3.10 / 1035.66 | 4 | 34 |
4 | 13 | 1630.68 | 36 | 13.11 | 1547 | 730 | 3.83 / 1036.39 | 4 | 40 |
5 | 13 | 1113.08 | 36 | 13.36 | 1183 | 569 | 4.40 / 1036.96 | 4 | 48 |
6 | 13 | 786.56 | 36 | 13.53 | 954 | 465 | 4.86 / 1037.42 | 4 | 53 |
7 | 13 | 115.92 | 36 | 14.08 | 409 | 207 | 5.07 / 1037.63 | 5 | 49 |
8 | 8 | -0.04 | 450 | 14.12 | 294 | 1868 | 6.94 / 1039.50 | 5 | 67 |
Average= | 6.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.84 | 80 | 14.08 | 374 | 421 | 0.42 / 1026.16 | 5 | 13 |
2 | 7 | 2009.08 | 105 | 10.20 | 1748 | 1872 | 2.29 / 1028.03 | 4 | 18 |
3 | 13 | 1930.24 | 36 | 12.88 | 1737 | 805 | 3.10 / 1028.83 | 4 | 35 |
4 | 13 | 1616.04 | 36 | 13.12 | 1531 | 723 | 3.82 / 1029.56 | 4 | 40 |
5 | 13 | 1091.08 | 36 | 13.38 | 1164 | 561 | 4.38 / 1030.12 | 4 | 47 |
6 | 13 | 671.96 | 36 | 13.60 | 864 | 423 | 4.81 / 1030.54 | 4 | 54 |
7 | 13 | 33.40 | 36 | 14.17 | 335 | 171 | 4.98 / 1030.71 | 5 | 47 |
8 | 8 | 0.16 | 450 | 14.10 | 292 | 1853 | 6.83 / 1032.56 | 5 | 63 |
Average= | 6.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.68 | 80 | 14.09 | 374 | 422 | 0.42 / 1019.21 | 5 | 14 |
2 | 7 | 2005.32 | 106 | 10.25 | 1743 | 1894 | 2.32 / 1021.10 | 14 | 19 |
3 | 13 | 1929.88 | 36 | 12.86 | 1742 | 806 | 3.12 / 1021.91 | 4 | 35 |
4 | 13 | 1832.56 | 36 | 12.99 | 1676 | 784 | 3.91 / 1022.69 | 4 | 38 |
5 | 13 | 1069.96 | 36 | 13.39 | 1152 | 555 | 4.46 / 1023.25 | 4 | 47 |
6 | 13 | 747.88 | 36 | 13.56 | 921 | 450 | 4.91 / 1023.70 | 4 | 53 |
7 | 13 | 92.36 | 36 | 14.11 | 385 | 196 | 5.11 / 1023.89 | 5 | 48 |
8 | 8 | 0.00 | 450 | 14.11 | 290 | 1841 | 6.95 / 1025.73 | 5 | 65 |
Average= | 6.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.56 | 80 | 14.08 | 375 | 422 | 0.42 / 1012.22 | 5 | 15 |
2 | 7 | 2017.40 | 106 | 10.22 | 1759 | 1906 | 2.33 / 1014.12 | 15 | 20 |
3 | 13 | 1949.24 | 36 | 12.85 | 1752 | 810 | 3.14 / 1014.93 | 4 | 35 |
4 | 13 | 1647.68 | 36 | 13.11 | 1557 | 735 | 3.87 / 1015.67 | 4 | 41 |
5 | 13 | 1229.32 | 36 | 13.30 | 1262 | 604 | 4.48 / 1016.27 | 4 | 46 |
6 | 13 | 711.20 | 36 | 13.59 | 892 | 436 | 4.91 / 1016.71 | 4 | 54 |
7 | 13 | 162.96 | 36 | 14.03 | 445 | 225 | 5.14 / 1016.93 | 5 | 50 |
8 | 8 | 0.04 | 450 | 14.11 | 292 | 1854 | 6.99 / 1018.79 | 5 | 76 |
Average= | 6.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.60 | 80 | 14.08 | 372 | 419 | 0.42 / 1005.28 | 5 | 16 |
2 | 7 | 2003.40 | 105 | 10.29 | 1744 | 1884 | 2.30 / 1007.16 | 4 | 20 |
3 | 13 | 1915.28 | 36 | 12.88 | 1722 | 798 | 3.10 / 1007.96 | 4 | 35 |
4 | 13 | 1613.48 | 36 | 13.13 | 1522 | 719 | 3.82 / 1008.68 | 4 | 40 |
5 | 13 | 1187.28 | 36 | 13.33 | 1232 | 591 | 4.41 / 1009.27 | 4 | 47 |
6 | 13 | 646.64 | 36 | 13.61 | 848 | 415 | 4.83 / 1009.69 | 4 | 54 |
7 | 13 | 216.60 | 36 | 13.98 | 491 | 247 | 5.08 / 1009.94 | 5 | 52 |
8 | 8 | 0.04 | 450 | 14.10 | 293 | 1859 | 6.93 / 1011.79 | 5 | 67 |
Average= | 6.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.40 | 80 | 14.09 | 368 | 415 | 0.41 / 998.46 | 5 | 15 |
2 | 7 | 2005.32 | 105 | 10.33 | 1741 | 1888 | 2.30 / 1000.35 | 15 | 19 |
3 | 13 | 1918.92 | 36 | 12.87 | 1732 | 802 | 3.11 / 1001.15 | 4 | 34 |
4 | 13 | 1506.68 | 36 | 13.17 | 1456 | 690 | 3.80 / 1001.84 | 4 | 41 |
5 | 13 | 1082.00 | 36 | 13.38 | 1155 | 556 | 4.35 / 1002.39 | 4 | 48 |
6 | 13 | 554.28 | 36 | 13.67 | 774 | 381 | 4.73 / 1002.78 | 4 | 55 |
7 | 13 | 117.88 | 36 | 14.08 | 411 | 208 | 4.94 / 1002.98 | 5 | 48 |
8 | 8 | 0.00 | 450 | 14.09 | 296 | 1877 | 6.82 / 1004.86 | 5 | 78 |
Average= | 6.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.76 | 80 | 14.06 | 379 | 426 | 0.43 / 991.61 | 5 | 16 |
2 | 7 | 2007.76 | 105 | 10.32 | 1754 | 1901 | 2.33 / 993.51 | 4 | 19 |
3 | 13 | 1925.68 | 36 | 12.87 | 1740 | 806 | 3.13 / 994.32 | 4 | 36 |
4 | 13 | 1732.56 | 36 | 13.07 | 1605 | 755 | 3.89 / 995.07 | 4 | 39 |
5 | 13 | 1093.60 | 36 | 13.38 | 1164 | 561 | 4.45 / 995.64 | 4 | 48 |
6 | 13 | 670.24 | 36 | 13.60 | 862 | 422 | 4.87 / 996.06 | 4 | 54 |
7 | 13 | 5.00 | 36 | 14.23 | 305 | 156 | 5.03 / 996.21 | 5 | 51 |
8 | 8 | 0.16 | 450 | 14.11 | 288 | 1829 | 6.86 / 998.04 | 5 | 59 |
Average= | 6.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.16 | 80 | 14.09 | 368 | 415 | 0.41 / 984.62 | 5 | 16 |
2 | 7 | 2007.48 | 105 | 10.35 | 1745 | 1896 | 2.31 / 986.51 | 16 | 21 |
3 | 13 | 1914.12 | 36 | 12.84 | 1733 | 801 | 3.11 / 987.31 | 4 | 37 |
4 | 13 | 1507.04 | 36 | 13.17 | 1449 | 687 | 3.80 / 988.00 | 4 | 42 |
5 | 13 | 1097.00 | 36 | 13.37 | 1166 | 561 | 4.36 / 988.56 | 4 | 47 |
6 | 13 | 670.52 | 36 | 13.59 | 863 | 422 | 4.78 / 988.99 | 4 | 53 |
7 | 13 | 57.32 | 36 | 14.16 | 354 | 180 | 4.96 / 989.17 | 5 | 45 |
8 | 13 | 15.16 | 36 | 14.19 | 318 | 162 | 5.13 / 989.33 | 5 | 44 |
9 | 8 | 0.16 | 450 | 14.09 | 293 | 1858 | 6.98 / 991.19 | 5 | 70 |
Average= | 6.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.84 | 80 | 14.08 | 366 | 412 | 0.41 / 977.95 | 5 | 15 |
2 | 7 | 2015.88 | 105 | 10.35 | 1752 | 1904 | 2.32 / 979.86 | 15 | 20 |
3 | 13 | 1928.40 | 36 | 12.86 | 1735 | 803 | 3.12 / 980.66 | 4 | 36 |
4 | 13 | 1613.28 | 36 | 13.11 | 1532 | 723 | 3.84 / 981.38 | 4 | 41 |
5 | 13 | 1099.28 | 36 | 13.37 | 1166 | 561 | 4.40 / 981.95 | 4 | 49 |
6 | 13 | 672.84 | 36 | 13.61 | 861 | 422 | 4.83 / 982.37 | 4 | 54 |
7 | 8 | 0.24 | 450 | 14.11 | 289 | 1835 | 6.66 / 984.20 | 5 | 64 |
Average= | 6.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.76 | 80 | 14.10 | 371 | 418 | 0.42 / 971.08 | 5 | 15 |
2 | 7 | 2005.32 | 105 | 10.41 | 1741 | 1903 | 2.32 / 972.98 | 15 | 20 |
3 | 13 | 1924.80 | 36 | 12.85 | 1736 | 803 | 3.12 / 973.78 | 4 | 35 |
4 | 13 | 1620.20 | 36 | 13.11 | 1535 | 724 | 3.85 / 974.51 | 4 | 40 |
5 | 13 | 1104.40 | 36 | 13.36 | 1173 | 564 | 4.41 / 975.07 | 4 | 48 |
6 | 13 | 670.68 | 36 | 13.59 | 862 | 422 | 4.83 / 975.49 | 4 | 54 |
7 | 13 | 110.88 | 36 | 14.10 | 399 | 203 | 5.04 / 975.70 | 5 | 49 |
8 | 8 | 0.00 | 450 | 14.10 | 291 | 1846 | 6.88 / 977.54 | 5 | 64 |
Average= | 6.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.16 | 80 | 14.09 | 369 | 416 | 0.42 / 964.23 | 5 | 16 |
2 | 7 | 2004.28 | 106 | 10.41 | 1751 | 1932 | 2.35 / 966.17 | 16 | 20 |
3 | 13 | 1924.44 | 36 | 12.84 | 1740 | 804 | 3.15 / 966.97 | 4 | 36 |
4 | 13 | 1627.08 | 36 | 13.10 | 1533 | 723 | 3.88 / 967.69 | 4 | 40 |
5 | 13 | 1093.08 | 36 | 13.36 | 1171 | 563 | 4.44 / 968.26 | 4 | 48 |
6 | 13 | 657.64 | 36 | 13.61 | 848 | 415 | 4.85 / 968.67 | 4 | 54 |
7 | 13 | 24.08 | 36 | 14.22 | 321 | 164 | 5.02 / 968.84 | 5 | 45 |
8 | 8 | 0.16 | 450 | 14.11 | 287 | 1822 | 6.84 / 970.66 | 5 | 68 |
Average= | 6.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.40 | 80 | 14.08 | 373 | 420 | 0.42 / 957.35 | 5 | 13 |
2 | 7 | 2004.28 | 106 | 10.47 | 1746 | 1938 | 2.36 / 959.29 | 13 | 21 |
3 | 13 | 1915.84 | 36 | 12.84 | 1728 | 799 | 3.16 / 960.09 | 4 | 35 |
4 | 13 | 1602.88 | 36 | 13.10 | 1522 | 718 | 3.87 / 960.81 | 4 | 40 |
5 | 13 | 1165.96 | 36 | 13.34 | 1214 | 583 | 4.46 / 961.39 | 4 | 47 |
6 | 13 | 627.52 | 36 | 13.62 | 832 | 408 | 4.87 / 961.80 | 4 | 54 |
7 | 13 | 44.56 | 36 | 14.18 | 340 | 174 | 5.04 / 961.97 | 5 | 46 |
8 | 8 | -0.12 | 450 | 14.09 | 291 | 1845 | 6.88 / 963.82 | 5 | 68 |
Average= | 6.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.40 | 80 | 14.08 | 374 | 421 | 0.42 / 950.49 | 5 | 14 |
2 | 7 | 2006.48 | 105 | 10.49 | 1754 | 1932 | 2.35 / 952.42 | 14 | 21 |
3 | 13 | 1920.84 | 36 | 12.84 | 1742 | 805 | 3.16 / 953.23 | 4 | 36 |
4 | 13 | 1603.36 | 36 | 13.10 | 1525 | 719 | 3.88 / 953.94 | 4 | 40 |
5 | 13 | 1161.28 | 36 | 13.33 | 1218 | 584 | 4.46 / 954.53 | 4 | 47 |
6 | 13 | 517.96 | 36 | 13.70 | 742 | 366 | 4.83 / 954.90 | 4 | 54 |
7 | 13 | 44.36 | 36 | 14.17 | 344 | 175 | 5.00 / 955.07 | 5 | 47 |
8 | 8 | 0.12 | 450 | 14.08 | 294 | 1863 | 6.87 / 956.93 | 5 | 68 |
Average= | 6.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.96 | 80 | 14.10 | 371 | 418 | 0.42 / 943.64 | 5 | 14 |
2 | 7 | 2003.64 | 105 | 10.53 | 1747 | 1932 | 2.35 / 945.58 | 14 | 20 |
3 | 13 | 1914.68 | 36 | 12.84 | 1732 | 801 | 3.15 / 946.38 | 4 | 36 |
4 | 13 | 1605.44 | 36 | 13.11 | 1519 | 717 | 3.87 / 947.09 | 4 | 42 |
5 | 13 | 1081.84 | 36 | 13.36 | 1168 | 562 | 4.43 / 947.66 | 4 | 47 |
6 | 13 | 557.28 | 36 | 13.66 | 778 | 383 | 4.81 / 948.04 | 4 | 53 |
7 | 13 | 12.96 | 36 | 14.20 | 319 | 163 | 4.97 / 948.20 | 5 | 44 |
8 | 8 | 0.04 | 450 | 14.06 | 295 | 1866 | 6.84 / 950.07 | 5 | 66 |
Average= | 6.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.96 | 80 | 14.12 | 367 | 415 | 0.41 / 936.76 | 5 | 14 |
2 | 7 | 2011.40 | 105 | 10.56 | 1748 | 1938 | 2.35 / 938.69 | 14 | 22 |
3 | 13 | 1920.36 | 36 | 12.84 | 1733 | 801 | 3.15 / 939.50 | 4 | 34 |
4 | 13 | 1610.80 | 36 | 13.10 | 1528 | 721 | 3.87 / 940.22 | 4 | 40 |
5 | 13 | 1186.32 | 36 | 13.32 | 1231 | 590 | 4.46 / 940.81 | 4 | 47 |
6 | 13 | 631.12 | 36 | 13.61 | 836 | 410 | 4.87 / 941.22 | 4 | 55 |
7 | 13 | 21.52 | 36 | 14.21 | 322 | 165 | 5.04 / 941.38 | 5 | 46 |
8 | 8 | 0.04 | 450 | 14.09 | 291 | 1845 | 6.88 / 943.23 | 5 | 61 |
Average= | 6.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.36 | 80 | 14.13 | 366 | 414 | 0.41 / 929.95 | 5 | 13 |
2 | 7 | 2004.04 | 105 | 10.60 | 1750 | 1948 | 2.36 / 931.90 | 13 | 22 |
3 | 13 | 1920.68 | 36 | 12.83 | 1734 | 801 | 3.16 / 932.70 | 4 | 36 |
4 | 13 | 1511.36 | 36 | 13.14 | 1459 | 690 | 3.85 / 933.39 | 4 | 42 |
5 | 13 | 1106.00 | 36 | 13.36 | 1176 | 566 | 4.42 / 933.95 | 4 | 48 |
6 | 13 | 552.00 | 36 | 13.66 | 770 | 379 | 4.80 / 934.33 | 4 | 55 |
7 | 13 | 54.08 | 36 | 14.17 | 347 | 177 | 4.97 / 934.51 | 5 | 47 |
8 | 8 | 0.04 | 450 | 14.08 | 289 | 1831 | 6.80 / 936.34 | 5 | 70 |
Average= | 6.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.96 | 80 | 14.12 | 365 | 412 | 0.41 / 923.05 | 5 | 12 |
2 | 7 | 2006.92 | 106 | 10.62 | 1754 | 1975 | 2.39 / 925.02 | 12 | 22 |
3 | 13 | 1912.40 | 36 | 12.83 | 1728 | 798 | 3.18 / 925.82 | 4 | 36 |
4 | 13 | 1593.48 | 36 | 13.10 | 1521 | 717 | 3.90 / 926.54 | 4 | 41 |
5 | 13 | 1073.80 | 36 | 13.37 | 1153 | 555 | 4.46 / 927.09 | 4 | 48 |
6 | 13 | 751.88 | 36 | 13.55 | 925 | 451 | 4.91 / 927.55 | 4 | 53 |
7 | 13 | 49.52 | 36 | 14.18 | 342 | 175 | 5.08 / 927.72 | 5 | 46 |
8 | 8 | 0.08 | 450 | 14.11 | 286 | 1816 | 6.90 / 929.54 | 5 | 61 |
Average= | 6.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.00 | 80 | 14.15 | 359 | 406 | 0.41 / 916.17 | 5 | 11 |
2 | 7 | 2003.72 | 105 | 10.66 | 1755 | 1964 | 2.37 / 918.14 | 11 | 21 |
3 | 13 | 1912.44 | 36 | 12.83 | 1737 | 802 | 3.17 / 918.94 | 4 | 36 |
4 | 13 | 1598.36 | 36 | 13.08 | 1526 | 719 | 3.89 / 919.66 | 4 | 42 |
5 | 13 | 962.04 | 36 | 13.41 | 1080 | 521 | 4.41 / 920.18 | 4 | 50 |
6 | 13 | 650.76 | 36 | 13.59 | 854 | 418 | 4.83 / 920.60 | 4 | 55 |
7 | 13 | 90.08 | 36 | 14.12 | 383 | 195 | 5.03 / 920.79 | 5 | 49 |
8 | 8 | 0.04 | 450 | 14.09 | 291 | 1845 | 6.87 / 922.64 | 5 | 58 |
Average= | 6.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.64 | 80 | 14.14 | 358 | 405 | 0.40 / 909.29 | 5 | 12 |
2 | 7 | 2002.92 | 105 | 10.73 | 1743 | 1964 | 2.37 / 911.25 | 12 | 22 |
3 | 13 | 1913.44 | 36 | 12.82 | 1726 | 797 | 3.17 / 912.05 | 4 | 35 |
4 | 13 | 1601.60 | 36 | 13.09 | 1520 | 716 | 3.88 / 912.76 | 4 | 41 |
5 | 13 | 1156.36 | 36 | 13.32 | 1217 | 584 | 4.47 / 913.35 | 4 | 48 |
6 | 13 | 613.76 | 36 | 13.63 | 816 | 400 | 4.87 / 913.75 | 4 | 55 |
7 | 13 | 86.08 | 36 | 14.12 | 380 | 193 | 5.06 / 913.94 | 5 | 48 |
8 | 8 | 0.08 | 450 | 14.10 | 288 | 1827 | 6.89 / 915.77 | 5 | 75 |
Average= | 6.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.24 | 80 | 14.15 | 356 | 403 | 0.40 / 902.34 | 5 | 12 |
2 | 7 | 2004.60 | 106 | 10.72 | 1749 | 1987 | 2.39 / 904.33 | 12 | 23 |
3 | 13 | 1909.52 | 36 | 12.83 | 1719 | 794 | 3.18 / 905.12 | 4 | 35 |
4 | 13 | 1710.48 | 36 | 13.03 | 1590 | 746 | 3.93 / 905.87 | 4 | 39 |
5 | 13 | 1160.64 | 36 | 13.32 | 1213 | 582 | 4.51 / 906.45 | 4 | 47 |
6 | 13 | 638.16 | 36 | 13.60 | 839 | 411 | 4.92 / 906.86 | 4 | 54 |
7 | 13 | 90.80 | 36 | 14.12 | 383 | 195 | 5.12 / 907.05 | 5 | 48 |
8 | 8 | -0.04 | 450 | 14.10 | 288 | 1827 | 6.94 / 908.88 | 5 | 71 |
Average= | 6.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.68 | 80 | 14.14 | 366 | 414 | 0.41 / 895.51 | 5 | 12 |
2 | 7 | 2005.44 | 105 | 10.77 | 1753 | 1982 | 2.40 / 897.49 | 12 | 23 |
3 | 13 | 1918.60 | 36 | 12.84 | 1731 | 800 | 3.20 / 898.29 | 4 | 35 |
4 | 13 | 1611.60 | 36 | 13.07 | 1526 | 718 | 3.91 / 899.01 | 4 | 41 |
5 | 13 | 1069.40 | 36 | 13.36 | 1150 | 553 | 4.47 / 899.56 | 4 | 48 |
6 | 13 | 539.68 | 36 | 13.68 | 757 | 373 | 4.84 / 899.93 | 4 | 55 |
7 | 13 | 51.36 | 36 | 14.17 | 344 | 175 | 5.02 / 900.11 | 5 | 47 |
8 | 8 | 0.16 | 450 | 14.10 | 288 | 1827 | 6.84 / 901.94 | 5 | 66 |
Average= | 6.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.80 | 80 | 14.15 | 359 | 406 | 0.41 / 888.57 | 5 | 11 |
2 | 7 | 2005.84 | 105 | 10.79 | 1755 | 1988 | 2.39 / 890.56 | 11 | 23 |
3 | 13 | 1910.76 | 36 | 12.82 | 1722 | 795 | 3.19 / 891.35 | 4 | 35 |
4 | 13 | 1713.20 | 36 | 13.03 | 1589 | 745 | 3.93 / 892.10 | 4 | 40 |
5 | 13 | 1062.72 | 36 | 13.36 | 1145 | 551 | 4.49 / 892.65 | 4 | 49 |
6 | 13 | 628.28 | 36 | 13.61 | 829 | 406 | 4.89 / 893.06 | 4 | 55 |
7 | 13 | 88.60 | 36 | 14.12 | 380 | 193 | 5.08 / 893.25 | 5 | 49 |
8 | 8 | -0.08 | 450 | 14.08 | 291 | 1844 | 6.93 / 895.09 | 5 | 62 |
Average= | 6.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.60 | 80 | 14.16 | 358 | 406 | 0.41 / 881.82 | 5 | 11 |
2 | 7 | 2009.16 | 105 | 10.84 | 1752 | 1994 | 2.40 / 883.81 | 11 | 23 |
3 | 13 | 1921.80 | 36 | 12.81 | 1728 | 797 | 3.20 / 884.61 | 4 | 36 |
4 | 13 | 1413.64 | 36 | 13.16 | 1387 | 657 | 3.85 / 885.27 | 4 | 43 |
5 | 13 | 1014.28 | 36 | 13.38 | 1113 | 536 | 4.39 / 885.80 | 4 | 50 |
6 | 13 | 502.12 | 36 | 13.70 | 733 | 362 | 4.75 / 886.16 | 4 | 55 |
7 | 13 | 47.80 | 36 | 14.18 | 344 | 176 | 4.93 / 886.34 | 5 | 48 |
8 | 8 | 0.08 | 450 | 14.08 | 288 | 1825 | 6.75 / 888.16 | 5 | 66 |
Average= | 6.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.76 | 80 | 14.16 | 364 | 412 | 0.41 / 874.86 | 5 | 11 |
2 | 7 | 2004.96 | 106 | 10.89 | 1751 | 2021 | 2.43 / 876.88 | 11 | 23 |
3 | 13 | 1914.56 | 36 | 12.82 | 1725 | 796 | 3.23 / 877.68 | 4 | 35 |
4 | 13 | 1710.04 | 36 | 13.01 | 1597 | 748 | 3.98 / 878.43 | 4 | 40 |
5 | 13 | 1048.80 | 36 | 13.37 | 1137 | 547 | 4.52 / 878.97 | 4 | 49 |
6 | 13 | 619.92 | 36 | 13.61 | 825 | 404 | 4.93 / 879.38 | 4 | 55 |
7 | 13 | 80.16 | 36 | 14.13 | 378 | 192 | 5.12 / 879.57 | 5 | 49 |
8 | 8 | 0.00 | 450 | 14.08 | 291 | 1844 | 6.97 / 881.41 | 5 | 72 |
Average= | 6.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.84 | 80 | 14.16 | 351 | 398 | 0.40 / 867.99 | 5 | 10 |
2 | 7 | 2006.72 | 106 | 10.90 | 1753 | 2025 | 2.42 / 870.01 | 10 | 23 |
3 | 13 | 1922.64 | 36 | 12.81 | 1726 | 796 | 3.22 / 870.81 | 4 | 34 |
4 | 13 | 1617.04 | 36 | 13.07 | 1529 | 719 | 3.94 / 871.53 | 4 | 41 |
5 | 13 | 975.84 | 36 | 13.40 | 1087 | 524 | 4.46 / 872.05 | 4 | 50 |
6 | 13 | 569.28 | 36 | 13.65 | 789 | 388 | 4.85 / 872.44 | 4 | 55 |
7 | 13 | 59.36 | 36 | 14.15 | 359 | 183 | 5.03 / 872.62 | 5 | 47 |
8 | 8 | 0.16 | 450 | 14.09 | 288 | 1826 | 6.86 / 874.45 | 5 | 66 |
Average= | 6.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.60 | 80 | 14.18 | 352 | 399 | 0.40 / 861.04 | 5 | 10 |
2 | 7 | 2003.44 | 106 | 10.93 | 1748 | 2025 | 2.42 / 863.07 | 10 | 23 |
3 | 13 | 1912.60 | 36 | 12.78 | 1726 | 794 | 3.22 / 863.86 | 4 | 35 |
4 | 13 | 1711.28 | 36 | 13.02 | 1591 | 746 | 3.96 / 864.61 | 4 | 40 |
5 | 13 | 1134.76 | 36 | 13.31 | 1199 | 575 | 4.54 / 865.18 | 4 | 48 |
6 | 13 | 604.84 | 36 | 13.62 | 812 | 398 | 4.94 / 865.58 | 4 | 54 |
7 | 13 | 80.60 | 36 | 14.12 | 371 | 189 | 5.13 / 865.77 | 5 | 48 |
8 | 8 | 0.00 | 450 | 14.08 | 287 | 1818 | 6.94 / 867.59 | 5 | 67 |
Average= | 6.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.40 | 80 | 14.19 | 348 | 395 | 0.40 / 854.29 | 5 | 9 |
2 | 7 | 2009.60 | 105 | 10.95 | 1750 | 2012 | 2.41 / 856.30 | 9 | 23 |
3 | 13 | 1923.00 | 36 | 12.80 | 1726 | 795 | 3.20 / 857.10 | 4 | 34 |
4 | 13 | 1509.48 | 36 | 13.11 | 1458 | 688 | 3.89 / 857.78 | 4 | 42 |
5 | 13 | 884.16 | 36 | 13.45 | 1020 | 494 | 4.38 / 858.28 | 4 | 50 |
6 | 13 | 571.20 | 36 | 13.66 | 782 | 385 | 4.77 / 858.66 | 4 | 55 |
7 | 13 | 33.96 | 36 | 14.19 | 333 | 170 | 4.94 / 858.83 | 5 | 46 |
8 | 8 | -0.04 | 450 | 14.08 | 286 | 1812 | 6.75 / 860.64 | 5 | 72 |
Average= | 6.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.00 | 80 | 14.15 | 361 | 409 | 0.41 / 847.31 | 5 | 9 |
2 | 7 | 2006.32 | 105 | 11.03 | 1752 | 2029 | 2.44 / 849.34 | 9 | 24 |
3 | 13 | 1924.04 | 36 | 12.80 | 1737 | 800 | 3.24 / 850.14 | 4 | 36 |
4 | 13 | 1412.04 | 36 | 13.17 | 1384 | 656 | 3.89 / 850.80 | 4 | 42 |
5 | 13 | 1006.64 | 36 | 13.38 | 1107 | 533 | 4.43 / 851.33 | 4 | 48 |
6 | 13 | 576.56 | 36 | 13.65 | 787 | 387 | 4.81 / 851.72 | 4 | 54 |
7 | 13 | 64.96 | 36 | 14.14 | 361 | 184 | 5.00 / 851.90 | 5 | 47 |
8 | 13 | 32.88 | 36 | 14.13 | 332 | 169 | 5.17 / 852.07 | 5 | 48 |
9 | 8 | 0.12 | 450 | 14.07 | 288 | 1823 | 6.99 / 853.89 | 5 | 78 |
Average= | 6.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.88 | 80 | 14.16 | 358 | 406 | 0.41 / 840.49 | 5 | 11 |
2 | 7 | 2004.64 | 106 | 11.05 | 1748 | 2047 | 2.45 / 842.54 | 11 | 24 |
3 | 13 | 1920.40 | 36 | 12.81 | 1721 | 794 | 3.25 / 843.34 | 4 | 35 |
4 | 13 | 1506.00 | 36 | 13.12 | 1447 | 683 | 3.93 / 844.02 | 4 | 41 |
5 | 13 | 887.28 | 36 | 13.43 | 1026 | 496 | 4.43 / 844.51 | 4 | 50 |
6 | 13 | 586.40 | 36 | 13.63 | 797 | 391 | 4.82 / 844.91 | 4 | 54 |
7 | 13 | 39.40 | 36 | 14.16 | 340 | 173 | 4.99 / 845.08 | 5 | 48 |
8 | 8 | 0.12 | 450 | 14.07 | 288 | 1823 | 6.81 / 846.90 | 5 | 75 |
Average= | 6.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.16 | 80 | 14.18 | 354 | 402 | 0.40 / 833.63 | 5 | 9 |
2 | 7 | 2011.20 | 105 | 11.08 | 1749 | 2035 | 2.44 / 835.66 | 9 | 25 |
3 | 13 | 1919.28 | 36 | 12.77 | 1732 | 796 | 3.23 / 836.46 | 4 | 37 |
4 | 13 | 1614.96 | 36 | 13.06 | 1519 | 714 | 3.95 / 837.17 | 4 | 42 |
5 | 13 | 1058.64 | 36 | 13.34 | 1146 | 550 | 4.50 / 837.72 | 4 | 48 |
6 | 13 | 518.48 | 36 | 13.68 | 741 | 365 | 4.86 / 838.09 | 4 | 54 |
7 | 13 | 84.08 | 36 | 14.11 | 377 | 192 | 5.05 / 838.28 | 5 | 49 |
8 | 8 | 0.12 | 450 | 14.06 | 286 | 1810 | 6.86 / 840.09 | 5 | 64 |
Average= | 6.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.80 | 80 | 14.17 | 355 | 402 | 0.40 / 826.91 | 5 | 10 |
2 | 7 | 2004.28 | 105 | 11.10 | 1761 | 2052 | 2.45 / 828.97 | 10 | 26 |
3 | 13 | 1910.44 | 36 | 12.78 | 1724 | 793 | 3.25 / 829.76 | 4 | 37 |
4 | 13 | 1403.68 | 36 | 13.15 | 1377 | 652 | 3.90 / 830.41 | 4 | 43 |
5 | 13 | 991.92 | 36 | 13.39 | 1092 | 526 | 4.43 / 830.94 | 4 | 48 |
6 | 13 | 368.92 | 36 | 13.81 | 620 | 308 | 4.73 / 831.25 | 4 | 53 |
7 | 13 | 44.72 | 36 | 14.17 | 344 | 175 | 4.91 / 831.42 | 5 | 47 |
8 | 8 | 0.00 | 450 | 14.07 | 285 | 1804 | 6.71 / 833.23 | 5 | 63 |
Average= | 6.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.12 | 80 | 14.16 | 355 | 402 | 0.40 / 820.15 | 5 | 11 |
2 | 7 | 2004.68 | 105 | 11.13 | 1759 | 2056 | 2.46 / 822.20 | 11 | 25 |
3 | 13 | 1919.80 | 36 | 12.77 | 1720 | 791 | 3.25 / 822.99 | 4 | 35 |
4 | 13 | 1607.56 | 36 | 13.04 | 1522 | 714 | 3.96 / 823.71 | 4 | 41 |
5 | 13 | 968.84 | 36 | 13.39 | 1077 | 519 | 4.48 / 824.23 | 4 | 50 |
6 | 13 | 352.08 | 36 | 13.82 | 603 | 300 | 4.78 / 824.53 | 4 | 53 |
7 | 13 | 63.16 | 36 | 14.15 | 354 | 180 | 4.96 / 824.71 | 5 | 47 |
8 | 8 | 0.00 | 450 | 14.07 | 285 | 1804 | 6.77 / 826.51 | 5 | 69 |
Average= | 6.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.56 | 80 | 14.16 | 364 | 412 | 0.41 / 813.12 | 5 | 10 |
2 | 7 | 2013.76 | 105 | 11.17 | 1764 | 2069 | 2.48 / 815.19 | 10 | 25 |
3 | 13 | 1923.44 | 36 | 12.77 | 1735 | 798 | 3.28 / 815.98 | 4 | 35 |
4 | 13 | 1724.44 | 36 | 12.99 | 1600 | 748 | 4.03 / 816.73 | 4 | 39 |
5 | 13 | 958.72 | 36 | 13.38 | 1078 | 519 | 4.55 / 817.25 | 4 | 49 |
6 | 13 | 860.68 | 36 | 13.43 | 1005 | 486 | 5.03 / 817.74 | 4 | 53 |
7 | 13 | 66.72 | 36 | 14.13 | 365 | 186 | 5.22 / 817.92 | 5 | 47 |
8 | 8 | 0.08 | 450 | 14.06 | 288 | 1822 | 7.04 / 819.74 | 5 | 68 |
Average= | 6.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.16 | 80 | 14.16 | 353 | 400 | 0.40 / 806.24 | 5 | 12 |
2 | 7 | 2006.92 | 105 | 11.23 | 1759 | 2074 | 2.47 / 808.32 | 12 | 26 |
3 | 13 | 1920.44 | 36 | 12.77 | 1731 | 796 | 3.27 / 809.11 | 4 | 36 |
4 | 13 | 1499.08 | 36 | 13.08 | 1449 | 682 | 3.95 / 809.80 | 4 | 42 |
5 | 13 | 1185.08 | 36 | 13.27 | 1231 | 588 | 4.54 / 810.38 | 4 | 48 |
6 | 13 | 428.96 | 36 | 13.75 | 666 | 330 | 4.87 / 810.71 | 4 | 55 |
7 | 13 | 47.60 | 36 | 14.17 | 341 | 174 | 5.04 / 810.89 | 5 | 47 |
8 | 8 | 0.12 | 450 | 14.07 | 287 | 1817 | 6.86 / 812.70 | 5 | 69 |
Average= | 6.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.28 | 80 | 14.13 | 368 | 416 | 0.42 / 799.38 | 5 | 10 |
2 | 7 | 2009.52 | 106 | 11.23 | 1767 | 2103 | 2.52 / 801.49 | 10 | 26 |
3 | 13 | 1921.00 | 36 | 12.74 | 1739 | 798 | 3.32 / 802.28 | 4 | 35 |
4 | 13 | 1604.04 | 36 | 13.02 | 1525 | 715 | 4.03 / 803.00 | 4 | 41 |
5 | 13 | 869.04 | 36 | 13.43 | 1006 | 486 | 4.52 / 803.49 | 4 | 51 |
6 | 13 | 445.48 | 36 | 13.73 | 682 | 337 | 4.86 / 803.82 | 4 | 54 |
7 | 13 | 107.00 | 36 | 14.09 | 394 | 200 | 5.06 / 804.02 | 5 | 49 |
8 | 8 | 0.04 | 450 | 14.05 | 288 | 1821 | 6.88 / 805.84 | 5 | 71 |
Average= | 6.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.28 | 80 | 14.12 | 363 | 410 | 0.41 / 792.56 | 5 | 12 |
2 | 7 | 2003.48 | 106 | 11.29 | 1752 | 2097 | 2.51 / 794.66 | 12 | 26 |
3 | 13 | 1908.96 | 36 | 12.76 | 1723 | 791 | 3.30 / 795.45 | 4 | 35 |
4 | 13 | 1385.08 | 36 | 13.14 | 1370 | 648 | 3.95 / 796.09 | 4 | 43 |
5 | 13 | 964.72 | 36 | 13.36 | 1081 | 520 | 4.47 / 796.61 | 4 | 49 |
6 | 13 | 443.72 | 36 | 13.72 | 687 | 339 | 4.81 / 796.95 | 4 | 55 |
7 | 13 | 27.56 | 36 | 14.19 | 327 | 167 | 4.97 / 797.12 | 5 | 45 |
8 | 8 | 0.24 | 450 | 14.05 | 292 | 1846 | 6.82 / 798.97 | 5 | 56 |
Average= | 6.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.64 | 80 | 14.11 | 369 | 417 | 0.42 / 785.72 | 5 | 12 |
2 | 7 | 2003.48 | 106 | 11.33 | 1752 | 2104 | 2.52 / 787.82 | 12 | 26 |
3 | 13 | 1907.16 | 36 | 12.77 | 1720 | 791 | 3.31 / 788.61 | 4 | 36 |
4 | 13 | 1489.48 | 36 | 13.08 | 1437 | 677 | 3.99 / 789.29 | 4 | 42 |
5 | 13 | 1071.56 | 36 | 13.32 | 1145 | 549 | 4.54 / 789.84 | 4 | 48 |
6 | 13 | 441.64 | 36 | 13.74 | 673 | 333 | 4.87 / 790.17 | 4 | 54 |
7 | 13 | 15.12 | 36 | 14.22 | 310 | 159 | 5.03 / 790.33 | 5 | 45 |
8 | 8 | 0.12 | 450 | 14.03 | 288 | 1818 | 6.85 / 792.15 | 5 | 62 |
Average= | 6.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.36 | 80 | 14.13 | 366 | 414 | 0.41 / 778.86 | 5 | 13 |
2 | 7 | 2007.20 | 106 | 11.34 | 1764 | 2120 | 2.53 / 780.98 | 13 | 27 |
3 | 13 | 1925.32 | 36 | 12.75 | 1727 | 793 | 3.33 / 781.78 | 4 | 35 |
4 | 13 | 1501.64 | 36 | 13.08 | 1446 | 681 | 4.01 / 782.46 | 4 | 42 |
5 | 13 | 885.52 | 36 | 13.41 | 1021 | 493 | 4.50 / 782.95 | 4 | 50 |
6 | 13 | 480.08 | 36 | 13.70 | 710 | 350 | 4.85 / 783.30 | 4 | 54 |
7 | 13 | 34.04 | 36 | 14.18 | 330 | 168 | 5.02 / 783.47 | 5 | 46 |
8 | 8 | 0.00 | 450 | 14.04 | 290 | 1832 | 6.85 / 785.30 | 5 | 66 |
Average= | 6.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.60 | 80 | 14.11 | 370 | 418 | 0.42 / 772.02 | 5 | 13 |
2 | 7 | 2005.32 | 106 | 11.37 | 1760 | 2121 | 2.54 / 774.14 | 13 | 26 |
3 | 13 | 1913.40 | 36 | 12.76 | 1726 | 793 | 3.33 / 774.94 | 4 | 35 |
4 | 13 | 1498.72 | 36 | 13.06 | 1448 | 681 | 4.01 / 775.62 | 4 | 42 |
5 | 13 | 960.04 | 36 | 13.37 | 1074 | 517 | 4.53 / 776.13 | 4 | 50 |
6 | 13 | 431.32 | 36 | 13.74 | 673 | 333 | 4.86 / 776.47 | 4 | 54 |
7 | 13 | 7.04 | 36 | 14.23 | 311 | 159 | 5.02 / 776.63 | 5 | 46 |
8 | 8 | 0.00 | 450 | 14.02 | 289 | 1823 | 6.84 / 778.45 | 5 | 62 |
Average= | 6.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.92 | 80 | 14.10 | 369 | 416 | 0.42 / 765.20 | 5 | 13 |
2 | 7 | 2006.96 | 106 | 11.43 | 1758 | 2130 | 2.55 / 767.33 | 13 | 27 |
3 | 13 | 1912.84 | 36 | 12.77 | 1721 | 791 | 3.34 / 768.12 | 4 | 35 |
4 | 13 | 1380.12 | 36 | 13.13 | 1364 | 645 | 3.98 / 768.76 | 4 | 44 |
5 | 13 | 959.24 | 36 | 13.38 | 1070 | 515 | 4.50 / 769.28 | 4 | 50 |
6 | 13 | 429.20 | 36 | 13.74 | 673 | 333 | 4.83 / 769.61 | 4 | 54 |
7 | 13 | 23.12 | 36 | 14.20 | 322 | 165 | 4.99 / 769.77 | 5 | 46 |
8 | 8 | 0.00 | 450 | 14.03 | 290 | 1831 | 6.83 / 771.60 | 5 | 63 |
Average= | 6.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.12 | 80 | 14.11 | 366 | 413 | 0.41 / 758.23 | 5 | 12 |
2 | 7 | 2003.16 | 106 | 11.44 | 1766 | 2142 | 2.55 / 760.37 | 12 | 27 |
3 | 13 | 1910.44 | 36 | 12.76 | 1726 | 793 | 3.35 / 761.16 | 4 | 35 |
4 | 13 | 1707.88 | 36 | 12.97 | 1592 | 743 | 4.09 / 761.91 | 4 | 40 |
5 | 13 | 1135.00 | 36 | 13.28 | 1194 | 571 | 4.66 / 762.48 | 4 | 47 |
6 | 13 | 372.52 | 36 | 13.80 | 620 | 308 | 4.97 / 762.79 | 4 | 53 |
7 | 13 | 16.04 | 36 | 14.21 | 320 | 164 | 5.13 / 762.95 | 5 | 44 |
8 | 8 | 0.04 | 450 | 14.01 | 290 | 1828 | 6.96 / 764.78 | 5 | 66 |
Average= | 6.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.16 | 80 | 14.11 | 371 | 419 | 0.42 / 751.35 | 5 | 13 |
2 | 7 | 2012.96 | 105 | 11.48 | 1764 | 2126 | 2.55 / 753.48 | 13 | 28 |
3 | 13 | 1918.40 | 36 | 12.76 | 1725 | 792 | 3.34 / 754.27 | 4 | 37 |
4 | 13 | 1508.40 | 36 | 13.06 | 1456 | 685 | 4.02 / 754.96 | 4 | 43 |
5 | 13 | 975.20 | 36 | 13.37 | 1082 | 521 | 4.54 / 755.48 | 4 | 50 |
6 | 13 | 444.60 | 36 | 13.74 | 682 | 337 | 4.88 / 755.81 | 4 | 53 |
7 | 13 | 24.32 | 36 | 14.19 | 325 | 166 | 5.05 / 755.98 | 5 | 43 |
8 | 8 | 0.12 | 450 | 14.03 | 291 | 1837 | 6.88 / 757.82 | 5 | 63 |
Average= | 6.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.48 | 80 | 14.10 | 366 | 413 | 0.41 / 744.58 | 5 | 15 |
2 | 7 | 2004.56 | 106 | 11.50 | 1760 | 2145 | 2.56 / 746.73 | 15 | 28 |
3 | 13 | 1914.24 | 36 | 12.77 | 1723 | 792 | 3.35 / 747.52 | 4 | 35 |
4 | 13 | 1507.56 | 36 | 13.07 | 1445 | 680 | 4.03 / 748.20 | 4 | 42 |
5 | 13 | 988.16 | 36 | 13.36 | 1093 | 526 | 4.56 / 748.72 | 4 | 50 |
6 | 13 | 556.40 | 36 | 13.65 | 771 | 379 | 4.93 / 749.10 | 4 | 54 |
7 | 8 | 0.08 | 450 | 14.04 | 290 | 1832 | 6.77 / 750.93 | 5 | 65 |
Average= | 6.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.76 | 79 | 14.09 | 374 | 416 | 0.42 / 737.66 | 5 | 15 |
2 | 3 | 1016.08 | 1 | 12.31 | 1116 | 14 | 0.43 / 737.68 | 4 | 5 |
3 | 7 | 2007.32 | 106 | 11.57 | 1766 | 2166 | 2.60 / 739.84 | 5 | 27 |
4 | 13 | 1919.76 | 36 | 12.78 | 1729 | 795 | 3.39 / 740.64 | 4 | 36 |
5 | 13 | 1492.32 | 36 | 13.08 | 1445 | 680 | 4.07 / 741.32 | 4 | 42 |
6 | 13 | 926.72 | 36 | 13.40 | 1051 | 507 | 4.58 / 741.82 | 4 | 50 |
7 | 13 | 490.32 | 36 | 13.70 | 720 | 355 | 4.93 / 742.18 | 4 | 54 |
8 | 13 | 13.88 | 36 | 14.21 | 314 | 161 | 5.09 / 742.34 | 5 | 46 |
9 | 8 | 0.12 | 450 | 14.00 | 290 | 1827 | 6.92 / 744.17 | 5 | 57 |
Average= | 6.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.52 | 78 | 14.11 | 372 | 409 | 0.41 / 730.99 | 5 | 13 |
2 | 3 | 1011.96 | 1 | 11.85 | 1111 | 13 | 0.42 / 731.00 | 4 | 4 |
3 | 7 | 2011.60 | 106 | 11.58 | 1756 | 2155 | 2.58 / 733.15 | 4 | 28 |
4 | 13 | 1919.04 | 36 | 12.78 | 1728 | 795 | 3.37 / 733.95 | 4 | 35 |
5 | 13 | 1391.08 | 36 | 13.14 | 1372 | 649 | 4.02 / 734.60 | 4 | 43 |
6 | 13 | 969.84 | 36 | 13.37 | 1084 | 522 | 4.54 / 735.12 | 4 | 49 |
7 | 13 | 333.40 | 36 | 13.84 | 591 | 294 | 4.84 / 735.41 | 4 | 52 |
8 | 8 | 0.08 | 450 | 14.03 | 290 | 1831 | 6.67 / 737.25 | 5 | 65 |
Average= | 6.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.32 | 78 | 14.11 | 374 | 412 | 0.41 / 723.99 | 5 | 15 |
2 | 7 | 2012.20 | 105 | 11.60 | 1759 | 2142 | 2.55 / 726.13 | 4 | 29 |
3 | 13 | 1912.56 | 36 | 12.78 | 1717 | 790 | 3.34 / 726.92 | 4 | 37 |
4 | 13 | 1610.04 | 36 | 13.02 | 1535 | 719 | 4.06 / 727.64 | 4 | 42 |
5 | 13 | 1157.56 | 36 | 13.28 | 1210 | 578 | 4.64 / 728.22 | 4 | 48 |
6 | 13 | 502.32 | 36 | 13.67 | 733 | 361 | 5.00 / 728.58 | 4 | 53 |
7 | 13 | 5.60 | 36 | 14.22 | 312 | 160 | 5.16 / 728.74 | 5 | 46 |
8 | 8 | -0.04 | 450 | 14.00 | 291 | 1833 | 7.00 / 730.58 | 5 | 63 |
Average= | 6.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.84 | 78 | 14.12 | 363 | 400 | 0.40 / 717.26 | 5 | 14 |
2 | 7 | 2007.12 | 105 | 11.59 | 1758 | 2139 | 2.54 / 719.40 | 4 | 27 |
3 | 13 | 1915.04 | 36 | 12.78 | 1722 | 792 | 3.33 / 720.19 | 4 | 35 |
4 | 13 | 1390.00 | 36 | 13.14 | 1372 | 649 | 3.98 / 720.84 | 4 | 43 |
5 | 13 | 984.92 | 36 | 13.36 | 1092 | 525 | 4.51 / 721.36 | 4 | 50 |
6 | 13 | 540.28 | 36 | 13.65 | 764 | 375 | 4.88 / 721.74 | 4 | 55 |
7 | 8 | 0.04 | 450 | 14.02 | 292 | 1842 | 6.72 / 723.58 | 5 | 68 |
Average= | 6.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.84 | 78 | 14.14 | 361 | 398 | 0.40 / 710.54 | 5 | 14 |
2 | 7 | 2013.04 | 106 | 11.57 | 1768 | 2168 | 2.57 / 712.71 | 4 | 28 |
3 | 13 | 1913.16 | 36 | 12.77 | 1727 | 794 | 3.36 / 713.51 | 4 | 36 |
4 | 13 | 1499.56 | 36 | 13.07 | 1457 | 686 | 4.05 / 714.19 | 4 | 42 |
5 | 13 | 964.60 | 36 | 13.37 | 1085 | 522 | 4.57 / 714.71 | 4 | 50 |
6 | 13 | 342.00 | 36 | 13.82 | 604 | 301 | 4.87 / 715.01 | 4 | 53 |
7 | 8 | 0.04 | 450 | 14.02 | 292 | 1842 | 6.71 / 716.86 | 5 | 70 |
Average= | 6.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.12 | 78 | 14.14 | 362 | 399 | 0.40 / 703.84 | 5 | 12 |
2 | 7 | 2012.04 | 105 | 11.66 | 1763 | 2158 | 2.56 / 705.99 | 4 | 29 |
3 | 13 | 1804.40 | 36 | 12.88 | 1656 | 768 | 3.33 / 706.76 | 4 | 37 |
4 | 13 | 1300.36 | 36 | 13.18 | 1316 | 624 | 3.95 / 707.39 | 4 | 44 |
5 | 13 | 893.64 | 36 | 13.41 | 1031 | 498 | 4.45 / 707.88 | 4 | 50 |
6 | 13 | 274.48 | 36 | 13.91 | 543 | 272 | 4.72 / 708.16 | 5 | 51 |
7 | 13 | 36.68 | 36 | 14.19 | 338 | 173 | 4.89 / 708.33 | 5 | 46 |
8 | 8 | 0.00 | 450 | 14.02 | 288 | 1817 | 6.71 / 710.15 | 5 | 60 |
Average= | 6.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.04 | 78 | 14.15 | 362 | 400 | 0.40 / 697.17 | 5 | 13 |
2 | 7 | 2003.36 | 105 | 11.62 | 1761 | 2149 | 2.55 / 699.31 | 13 | 28 |
3 | 13 | 1906.52 | 36 | 12.77 | 1720 | 791 | 3.34 / 700.10 | 4 | 36 |
4 | 13 | 1483.68 | 36 | 13.08 | 1439 | 678 | 4.02 / 700.78 | 4 | 42 |
5 | 13 | 947.16 | 36 | 13.38 | 1065 | 513 | 4.53 / 701.30 | 4 | 50 |
6 | 13 | 414.32 | 36 | 13.75 | 666 | 330 | 4.86 / 701.62 | 4 | 54 |
7 | 8 | 0.24 | 450 | 14.03 | 287 | 1812 | 6.67 / 703.44 | 5 | 64 |
Average= | 6.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.92 | 78 | 14.15 | 367 | 405 | 0.41 / 690.37 | 5 | 12 |
2 | 7 | 2005.68 | 105 | 11.64 | 1768 | 2161 | 2.57 / 692.53 | 12 | 29 |
3 | 13 | 1912.00 | 36 | 12.77 | 1724 | 793 | 3.36 / 693.32 | 4 | 37 |
4 | 13 | 1484.36 | 36 | 13.09 | 1440 | 679 | 4.04 / 694.00 | 4 | 42 |
5 | 13 | 946.60 | 36 | 13.39 | 1068 | 515 | 4.55 / 694.52 | 4 | 49 |
6 | 13 | 310.68 | 36 | 13.86 | 577 | 288 | 4.84 / 694.80 | 4 | 52 |
7 | 13 | 3.00 | 36 | 14.25 | 306 | 157 | 5.00 / 694.96 | 5 | 47 |
8 | 8 | 0.12 | 450 | 14.02 | 286 | 1804 | 6.80 / 696.77 | 5 | 66 |
Average= | 6.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.84 | 78 | 14.16 | 360 | 398 | 0.40 / 683.82 | 5 | 12 |
2 | 7 | 2002.76 | 105 | 11.67 | 1764 | 2162 | 2.56 / 685.99 | 12 | 30 |
3 | 13 | 1801.84 | 36 | 12.88 | 1654 | 767 | 3.33 / 686.75 | 4 | 39 |
4 | 13 | 1299.88 | 36 | 13.19 | 1314 | 624 | 3.95 / 687.38 | 4 | 45 |
5 | 13 | 801.72 | 36 | 13.47 | 968 | 469 | 4.42 / 687.85 | 4 | 49 |
6 | 13 | 385.40 | 36 | 13.78 | 645 | 320 | 4.74 / 688.17 | 4 | 53 |
7 | 8 | 0.12 | 450 | 14.03 | 285 | 1799 | 6.54 / 689.96 | 5 | 59 |
Average= | 6.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.44 | 78 | 14.19 | 361 | 400 | 0.40 / 677.20 | 5 | 12 |
2 | 7 | 2004.60 | 106 | 11.67 | 1763 | 2181 | 2.58 / 679.38 | 12 | 28 |
3 | 13 | 1914.08 | 36 | 12.77 | 1724 | 793 | 3.37 / 680.18 | 4 | 35 |
4 | 13 | 1401.00 | 36 | 13.13 | 1385 | 655 | 4.03 / 680.83 | 4 | 43 |
5 | 13 | 873.52 | 36 | 13.44 | 1014 | 491 | 4.52 / 681.32 | 4 | 51 |
6 | 13 | 259.20 | 36 | 13.92 | 534 | 268 | 4.79 / 681.59 | 5 | 52 |
7 | 8 | 0.00 | 450 | 14.03 | 291 | 1837 | 6.62 / 683.43 | 5 | 68 |
Average= | 6.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.88 | 78 | 14.18 | 368 | 407 | 0.41 / 670.35 | 5 | 11 |
2 | 7 | 2005.72 | 105 | 11.66 | 1776 | 2174 | 2.58 / 672.53 | 11 | 30 |
3 | 13 | 1916.88 | 36 | 12.77 | 1732 | 796 | 3.38 / 673.32 | 4 | 36 |
4 | 13 | 1376.12 | 36 | 13.15 | 1367 | 647 | 4.02 / 673.97 | 4 | 44 |
5 | 13 | 962.28 | 36 | 13.39 | 1078 | 520 | 4.54 / 674.49 | 4 | 51 |
6 | 13 | 417.76 | 36 | 13.78 | 664 | 329 | 4.87 / 674.82 | 4 | 55 |
7 | 13 | 47.20 | 36 | 14.18 | 344 | 176 | 5.05 / 674.99 | 5 | 48 |
8 | 8 | -0.04 | 450 | 14.05 | 286 | 1808 | 6.86 / 676.80 | 5 | 65 |
Average= | 6.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.60 | 78 | 14.18 | 366 | 405 | 0.40 / 663.32 | 5 | 12 |
2 | 7 | 2010.44 | 106 | 11.68 | 1775 | 2198 | 2.60 / 665.51 | 12 | 29 |
3 | 13 | 1913.28 | 36 | 12.77 | 1729 | 795 | 3.40 / 666.31 | 4 | 35 |
4 | 13 | 1476.60 | 36 | 13.09 | 1437 | 677 | 4.07 / 666.99 | 4 | 43 |
5 | 13 | 1031.64 | 36 | 13.35 | 1129 | 543 | 4.62 / 667.53 | 4 | 50 |
6 | 13 | 586.04 | 36 | 13.62 | 809 | 397 | 5.01 / 667.93 | 4 | 55 |
7 | 13 | 50.60 | 36 | 14.17 | 348 | 178 | 5.19 / 668.10 | 5 | 48 |
8 | 8 | 0.16 | 450 | 14.02 | 292 | 1842 | 7.03 / 669.95 | 5 | 61 |
Average= | 6.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.04 | 78 | 14.19 | 360 | 398 | 0.40 / 656.39 | 5 | 11 |
2 | 7 | 2004.44 | 105 | 11.69 | 1772 | 2175 | 2.57 / 658.56 | 11 | 28 |
3 | 13 | 1903.60 | 36 | 12.78 | 1724 | 793 | 3.37 / 659.35 | 4 | 36 |
4 | 13 | 1375.56 | 36 | 13.16 | 1365 | 647 | 4.01 / 660.00 | 4 | 44 |
5 | 13 | 948.16 | 36 | 13.39 | 1077 | 519 | 4.53 / 660.52 | 4 | 51 |
6 | 13 | 504.48 | 36 | 13.68 | 745 | 367 | 4.90 / 660.89 | 4 | 56 |
7 | 13 | 34.16 | 36 | 14.19 | 337 | 172 | 5.07 / 661.06 | 5 | 48 |
8 | 8 | 0.08 | 450 | 14.01 | 294 | 1854 | 6.93 / 662.91 | 5 | 68 |
Average= | 6.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.36 | 78 | 14.20 | 365 | 404 | 0.40 / 649.40 | 5 | 12 |
2 | 7 | 2013.68 | 106 | 11.70 | 1776 | 2203 | 2.61 / 651.61 | 12 | 29 |
3 | 13 | 1915.08 | 36 | 12.79 | 1732 | 797 | 3.40 / 652.40 | 4 | 36 |
4 | 13 | 1481.76 | 36 | 13.10 | 1439 | 679 | 4.08 / 653.08 | 4 | 43 |
5 | 13 | 916.64 | 36 | 13.42 | 1056 | 510 | 4.59 / 653.59 | 4 | 52 |
6 | 13 | 484.56 | 36 | 13.70 | 730 | 360 | 4.95 / 653.95 | 4 | 56 |
7 | 13 | 15.28 | 36 | 14.20 | 327 | 167 | 5.12 / 654.12 | 5 | 48 |
8 | 8 | 0.04 | 450 | 13.96 | 297 | 1866 | 6.99 / 655.99 | 5 | 69 |
Average= | 6.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.68 | 78 | 14.19 | 362 | 401 | 0.40 / 642.63 | 5 | 10 |
2 | 7 | 2012.04 | 105 | 11.73 | 1772 | 2182 | 2.58 / 644.82 | 10 | 29 |
3 | 13 | 1818.20 | 36 | 12.87 | 1671 | 774 | 3.36 / 645.59 | 4 | 37 |
4 | 13 | 1300.44 | 36 | 13.20 | 1321 | 628 | 3.99 / 646.22 | 4 | 44 |
5 | 13 | 976.84 | 36 | 13.39 | 1095 | 528 | 4.51 / 646.75 | 4 | 50 |
6 | 13 | 233.64 | 36 | 13.95 | 518 | 260 | 4.77 / 647.01 | 5 | 52 |
7 | 13 | 1.24 | 36 | 14.26 | 306 | 157 | 4.93 / 647.16 | 5 | 52 |
8 | 8 | 0.20 | 450 | 13.99 | 292 | 1838 | 6.77 / 649.00 | 5 | 57 |
Average= | 6.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.28 | 78 | 14.21 | 361 | 400 | 0.40 / 635.76 | 5 | 11 |
2 | 7 | 2014.48 | 106 | 11.72 | 1777 | 2208 | 2.61 / 637.97 | 11 | 31 |
3 | 13 | 1816.60 | 36 | 12.88 | 1674 | 776 | 3.38 / 638.74 | 4 | 39 |
4 | 13 | 1304.44 | 36 | 13.20 | 1325 | 630 | 4.01 / 639.37 | 4 | 45 |
5 | 13 | 813.68 | 36 | 13.48 | 982 | 477 | 4.49 / 639.85 | 4 | 52 |
6 | 13 | 388.16 | 36 | 13.79 | 653 | 324 | 4.81 / 640.17 | 4 | 54 |
7 | 13 | 74.84 | 36 | 14.12 | 383 | 195 | 5.01 / 640.37 | 5 | 49 |
8 | 8 | 0.00 | 450 | 14.00 | 296 | 1865 | 6.87 / 642.23 | 5 | 62 |
Average= | 6.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.04 | 78 | 14.21 | 362 | 401 | 0.40 / 628.85 | 5 | 11 |
2 | 7 | 2010.56 | 105 | 11.75 | 1775 | 2190 | 2.59 / 631.04 | 11 | 29 |
3 | 13 | 1909.76 | 36 | 12.79 | 1731 | 797 | 3.39 / 631.83 | 4 | 36 |
4 | 13 | 1384.40 | 36 | 13.15 | 1378 | 652 | 4.04 / 632.49 | 4 | 44 |
5 | 13 | 852.60 | 36 | 13.46 | 1013 | 491 | 4.53 / 632.98 | 4 | 52 |
6 | 13 | 434.72 | 36 | 13.75 | 695 | 344 | 4.88 / 633.32 | 4 | 57 |
7 | 13 | 45.88 | 36 | 14.17 | 354 | 181 | 5.06 / 633.50 | 5 | 49 |
8 | 8 | -0.08 | 450 | 13.99 | 295 | 1857 | 6.91 / 635.36 | 5 | 66 |
Average= | 6.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.68 | 78 | 14.21 | 369 | 409 | 0.41 / 621.83 | 5 | 11 |
2 | 7 | 2005.88 | 105 | 11.75 | 1768 | 2181 | 2.59 / 624.01 | 11 | 29 |
3 | 13 | 1911.88 | 36 | 12.78 | 1733 | 797 | 3.39 / 624.80 | 4 | 36 |
4 | 13 | 1387.00 | 36 | 13.15 | 1386 | 656 | 4.04 / 625.46 | 4 | 44 |
5 | 13 | 946.76 | 36 | 13.41 | 1078 | 520 | 4.56 / 625.98 | 4 | 52 |
6 | 13 | 302.16 | 36 | 13.88 | 583 | 291 | 4.86 / 626.27 | 4 | 55 |
7 | 13 | 46.88 | 36 | 14.18 | 356 | 182 | 5.04 / 626.45 | 5 | 50 |
8 | 13 | 7.32 | 36 | 14.17 | 315 | 161 | 5.20 / 626.61 | 5 | 48 |
9 | 8 | 0.08 | 450 | 13.98 | 291 | 1831 | 7.03 / 628.45 | 5 | 61 |
Average= | 6.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.16 | 78 | 14.22 | 363 | 403 | 0.40 / 614.90 | 5 | 11 |
2 | 7 | 2006.60 | 105 | 11.74 | 1775 | 2188 | 2.59 / 617.09 | 11 | 29 |
3 | 13 | 1918.88 | 36 | 12.78 | 1738 | 800 | 3.39 / 617.89 | 4 | 36 |
4 | 13 | 1292.36 | 36 | 13.21 | 1313 | 624 | 4.01 / 618.51 | 4 | 46 |
5 | 13 | 876.28 | 36 | 13.46 | 1026 | 497 | 4.51 / 619.01 | 4 | 51 |
6 | 13 | 447.64 | 36 | 13.75 | 707 | 350 | 4.86 / 619.36 | 4 | 56 |
7 | 13 | 46.68 | 36 | 14.16 | 364 | 186 | 5.05 / 619.55 | 5 | 51 |
8 | 8 | 0.04 | 450 | 14.00 | 297 | 1871 | 6.92 / 621.42 | 5 | 64 |
Average= | 6.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.16 | 78 | 14.21 | 357 | 396 | 0.40 / 607.92 | 5 | 10 |
2 | 7 | 2010.96 | 106 | 11.78 | 1771 | 2211 | 2.61 / 610.13 | 10 | 29 |
3 | 13 | 1920.40 | 36 | 12.78 | 1736 | 799 | 3.41 / 610.93 | 4 | 36 |
4 | 13 | 1393.92 | 36 | 13.16 | 1394 | 660 | 4.07 / 611.59 | 4 | 44 |
5 | 13 | 970.96 | 36 | 13.40 | 1099 | 530 | 4.60 / 612.12 | 4 | 51 |
6 | 13 | 433.40 | 36 | 13.75 | 699 | 346 | 4.94 / 612.46 | 4 | 57 |
7 | 13 | 45.00 | 36 | 14.17 | 358 | 183 | 5.13 / 612.64 | 5 | 51 |
8 | 8 | 0.08 | 450 | 14.01 | 294 | 1854 | 6.98 / 614.50 | 5 | 57 |
Average= | 6.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.16 | 78 | 14.22 | 370 | 410 | 0.41 / 600.92 | 5 | 11 |
2 | 7 | 2008.28 | 105 | 11.78 | 1768 | 2187 | 2.60 / 603.10 | 11 | 30 |
3 | 13 | 1811.84 | 36 | 12.90 | 1672 | 776 | 3.37 / 603.88 | 4 | 38 |
4 | 13 | 1513.60 | 36 | 13.11 | 1475 | 696 | 4.07 / 604.57 | 4 | 43 |
5 | 13 | 875.16 | 36 | 13.45 | 1031 | 499 | 4.57 / 605.07 | 4 | 52 |
6 | 13 | 245.36 | 36 | 13.93 | 542 | 272 | 4.84 / 605.35 | 5 | 54 |
7 | 13 | 34.84 | 36 | 14.18 | 348 | 178 | 5.02 / 605.52 | 5 | 51 |
8 | 13 | 1.12 | 36 | 14.16 | 308 | 157 | 5.18 / 605.68 | 5 | 50 |
9 | 8 | -0.08 | 450 | 13.95 | 293 | 1839 | 7.01 / 607.52 | 5 | 65 |
Average= | 6.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.72 | 78 | 14.21 | 372 | 412 | 0.41 / 593.97 | 5 | 11 |
2 | 7 | 2013.72 | 106 | 11.77 | 1788 | 2231 | 2.64 / 596.20 | 11 | 30 |
3 | 13 | 1913.88 | 36 | 12.80 | 1734 | 799 | 3.44 / 597.00 | 4 | 37 |
4 | 13 | 1384.68 | 36 | 13.18 | 1388 | 659 | 4.10 / 597.66 | 4 | 44 |
5 | 13 | 854.72 | 36 | 13.48 | 1022 | 496 | 4.60 / 598.15 | 4 | 52 |
6 | 13 | 328.28 | 36 | 13.87 | 611 | 305 | 4.90 / 598.46 | 4 | 56 |
7 | 13 | 53.44 | 36 | 14.16 | 366 | 187 | 5.09 / 598.65 | 5 | 52 |
8 | 8 | 0.04 | 450 | 14.00 | 295 | 1858 | 6.95 / 600.50 | 5 | 68 |
Average= | 6.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.24 | 78 | 14.20 | 366 | 405 | 0.41 / 587.09 | 5 | 11 |
2 | 7 | 2013.16 | 105 | 11.78 | 1780 | 2202 | 2.61 / 589.30 | 11 | 29 |
3 | 13 | 1711.36 | 36 | 12.97 | 1608 | 751 | 3.36 / 590.05 | 4 | 39 |
4 | 13 | 1309.72 | 36 | 13.22 | 1342 | 639 | 4.00 / 590.68 | 4 | 46 |
5 | 13 | 899.24 | 36 | 13.46 | 1054 | 511 | 4.51 / 591.20 | 4 | 51 |
6 | 13 | 380.12 | 36 | 13.81 | 660 | 328 | 4.84 / 591.52 | 4 | 56 |
7 | 13 | 36.76 | 36 | 14.18 | 353 | 180 | 5.02 / 591.70 | 5 | 51 |
8 | 8 | 0.00 | 450 | 13.97 | 295 | 1855 | 6.87 / 593.56 | 5 | 65 |
Average= | 6.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.28 | 78 | 14.19 | 375 | 415 | 0.42 / 580.03 | 5 | 12 |
2 | 7 | 2008.24 | 105 | 11.79 | 1786 | 2211 | 2.63 / 582.24 | 12 | 30 |
3 | 13 | 1916.92 | 36 | 12.80 | 1742 | 803 | 3.43 / 583.04 | 4 | 37 |
4 | 13 | 1382.76 | 36 | 13.18 | 1388 | 659 | 4.09 / 583.70 | 4 | 44 |
5 | 13 | 952.84 | 36 | 13.44 | 1093 | 529 | 4.62 / 584.23 | 4 | 52 |
6 | 13 | 609.76 | 36 | 13.64 | 843 | 414 | 5.03 / 584.64 | 4 | 56 |
7 | 13 | 30.68 | 36 | 14.19 | 349 | 178 | 5.21 / 584.82 | 5 | 51 |
8 | 8 | 0.04 | 450 | 13.97 | 297 | 1867 | 7.08 / 586.69 | 5 | 57 |
Average= | 6.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.92 | 78 | 14.21 | 372 | 412 | 0.41 / 572.91 | 5 | 12 |
2 | 7 | 2003.44 | 105 | 11.82 | 1773 | 2200 | 2.61 / 575.11 | 12 | 30 |
3 | 13 | 1904.72 | 36 | 12.81 | 1726 | 796 | 3.41 / 575.90 | 4 | 36 |
4 | 13 | 1579.64 | 36 | 13.08 | 1523 | 717 | 4.13 / 576.62 | 4 | 43 |
5 | 13 | 917.84 | 36 | 13.45 | 1068 | 517 | 4.64 / 577.14 | 4 | 51 |
6 | 13 | 588.40 | 36 | 13.66 | 825 | 406 | 5.05 / 577.54 | 4 | 56 |
7 | 13 | 50.68 | 36 | 14.16 | 371 | 189 | 5.24 / 577.73 | 5 | 52 |
8 | 8 | 0.00 | 450 | 13.98 | 299 | 1881 | 7.12 / 579.61 | 5 | 72 |
Average= | 6.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.28 | 78 | 14.21 | 373 | 413 | 0.41 / 565.90 | 5 | 12 |
2 | 7 | 2005.04 | 105 | 11.81 | 1775 | 2201 | 2.61 / 568.10 | 12 | 31 |
3 | 13 | 1908.12 | 36 | 12.82 | 1730 | 798 | 3.41 / 568.90 | 4 | 37 |
4 | 13 | 1484.84 | 36 | 13.13 | 1457 | 689 | 4.10 / 569.58 | 4 | 44 |
5 | 13 | 847.40 | 36 | 13.49 | 1025 | 498 | 4.60 / 570.08 | 4 | 52 |
6 | 13 | 425.64 | 36 | 13.78 | 694 | 344 | 4.94 / 570.43 | 4 | 57 |
7 | 13 | 43.84 | 36 | 14.18 | 361 | 184 | 5.13 / 570.61 | 5 | 51 |
8 | 8 | 0.00 | 450 | 13.99 | 299 | 1882 | 7.01 / 572.49 | 5 | 58 |
Average= | 6.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.56 | 78 | 14.21 | 378 | 419 | 0.42 / 558.90 | 5 | 11 |
2 | 7 | 2014.16 | 105 | 11.79 | 1781 | 2205 | 2.62 / 561.11 | 11 | 31 |
3 | 13 | 1927.40 | 36 | 12.79 | 1750 | 806 | 3.43 / 561.91 | 4 | 38 |
4 | 13 | 1400.96 | 36 | 13.18 | 1399 | 664 | 4.09 / 562.58 | 4 | 45 |
5 | 13 | 985.96 | 36 | 13.43 | 1112 | 538 | 4.63 / 563.12 | 4 | 50 |
6 | 13 | 333.76 | 36 | 13.88 | 615 | 307 | 4.94 / 563.42 | 4 | 55 |
7 | 13 | 29.36 | 36 | 14.22 | 340 | 174 | 5.11 / 563.60 | 5 | 49 |
8 | 8 | 0.12 | 450 | 13.97 | 300 | 1886 | 7.00 / 565.48 | 5 | 64 |
Average= | 6.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.20 | 78 | 14.19 | 381 | 422 | 0.42 / 551.90 | 5 | 13 |
2 | 7 | 2003.16 | 106 | 11.81 | 1782 | 2231 | 2.65 / 554.13 | 13 | 30 |
3 | 13 | 1701.72 | 36 | 12.98 | 1609 | 752 | 3.40 / 554.88 | 4 | 40 |
4 | 13 | 1498.32 | 36 | 13.13 | 1474 | 697 | 4.10 / 555.58 | 4 | 44 |
5 | 13 | 756.32 | 36 | 13.55 | 957 | 467 | 4.57 / 556.05 | 4 | 53 |
6 | 13 | 437.04 | 36 | 13.78 | 710 | 352 | 4.92 / 556.40 | 4 | 57 |
7 | 13 | 20.28 | 36 | 14.22 | 339 | 174 | 5.09 / 556.57 | 5 | 50 |
8 | 8 | 0.00 | 450 | 13.97 | 304 | 1911 | 7.00 / 558.49 | 5 | 72 |
Average= | 6.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.40 | 78 | 14.22 | 374 | 415 | 0.41 / 544.82 | 5 | 13 |
2 | 7 | 2007.08 | 106 | 11.82 | 1779 | 2229 | 2.64 / 547.05 | 13 | 30 |
3 | 13 | 1910.28 | 36 | 12.81 | 1738 | 801 | 3.45 / 547.85 | 4 | 37 |
4 | 13 | 1475.72 | 36 | 13.14 | 1457 | 689 | 4.13 / 548.54 | 4 | 44 |
5 | 13 | 1026.96 | 36 | 13.41 | 1151 | 556 | 4.69 / 549.09 | 4 | 51 |
6 | 13 | 276.04 | 36 | 13.94 | 571 | 287 | 4.98 / 549.38 | 4 | 55 |
7 | 13 | 37.20 | 36 | 14.21 | 351 | 180 | 5.16 / 549.56 | 5 | 50 |
8 | 8 | 0.08 | 450 | 13.96 | 306 | 1922 | 7.08 / 551.48 | 5 | 69 |
Average= | 6.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.00 | 78 | 14.19 | 380 | 421 | 0.42 / 537.62 | 5 | 14 |
2 | 7 | 2007.28 | 105 | 11.80 | 1778 | 2203 | 2.62 / 539.82 | 14 | 30 |
3 | 13 | 1921.48 | 36 | 12.78 | 1753 | 807 | 3.43 / 540.63 | 4 | 37 |
4 | 13 | 1499.64 | 36 | 13.14 | 1467 | 694 | 4.12 / 541.32 | 4 | 43 |
5 | 13 | 1073.76 | 36 | 13.40 | 1178 | 568 | 4.69 / 541.89 | 4 | 50 |
6 | 13 | 513.24 | 36 | 13.75 | 762 | 377 | 5.07 / 542.26 | 4 | 56 |
7 | 13 | 81.56 | 36 | 14.17 | 388 | 198 | 5.27 / 542.46 | 5 | 50 |
8 | 8 | -0.04 | 450 | 13.99 | 308 | 1939 | 7.21 / 544.40 | 5 | 68 |
Average= | 6.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.52 | 78 | 14.17 | 387 | 428 | 0.43 / 530.54 | 5 | 13 |
2 | 7 | 2003.56 | 105 | 11.82 | 1777 | 2205 | 2.63 / 532.75 | 13 | 31 |
3 | 13 | 1803.72 | 36 | 12.93 | 1668 | 776 | 3.41 / 533.52 | 4 | 40 |
4 | 13 | 1286.20 | 36 | 13.27 | 1325 | 633 | 4.04 / 534.16 | 4 | 47 |
5 | 13 | 871.60 | 36 | 13.50 | 1042 | 506 | 4.55 / 534.66 | 4 | 53 |
6 | 13 | 552.92 | 36 | 13.72 | 804 | 397 | 4.95 / 535.06 | 4 | 56 |
7 | 13 | 42.28 | 36 | 14.21 | 361 | 185 | 5.13 / 535.25 | 5 | 49 |
8 | 8 | 0.12 | 450 | 13.98 | 310 | 1950 | 7.08 / 537.20 | 5 | 63 |
Average= | 6.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.16 | 78 | 14.18 | 388 | 429 | 0.43 / 523.58 | 5 | 15 |
2 | 7 | 2013.08 | 106 | 11.82 | 1790 | 2243 | 2.67 / 525.82 | 15 | 31 |
3 | 13 | 1715.80 | 36 | 13.01 | 1618 | 758 | 3.43 / 526.58 | 4 | 39 |
4 | 13 | 1410.76 | 36 | 13.21 | 1414 | 672 | 4.10 / 527.25 | 4 | 45 |
5 | 13 | 970.48 | 36 | 13.46 | 1112 | 539 | 4.64 / 527.79 | 4 | 52 |
6 | 13 | 408.28 | 36 | 13.84 | 687 | 342 | 4.98 / 528.13 | 4 | 56 |
7 | 8 | 0.04 | 450 | 13.97 | 315 | 1980 | 6.96 / 530.11 | 5 | 61 |
Average= | 6.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.20 | 77 | 14.21 | 379 | 415 | 0.41 / 516.69 | 5 | 15 |
2 | 3 | 1009.88 | 1 | 12.10 | 1127 | 14 | 0.43 / 516.70 | 4 | 4 |
3 | 7 | 2005.08 | 106 | 11.83 | 1773 | 2223 | 2.65 / 518.93 | 4 | 31 |
4 | 13 | 1801.60 | 36 | 12.93 | 1677 | 781 | 3.43 / 519.71 | 4 | 40 |
5 | 13 | 1289.28 | 36 | 13.28 | 1325 | 633 | 4.07 / 520.34 | 4 | 47 |
6 | 13 | 875.40 | 36 | 13.52 | 1045 | 509 | 4.57 / 520.85 | 4 | 53 |
7 | 13 | 446.68 | 36 | 13.82 | 716 | 356 | 4.93 / 521.20 | 4 | 56 |
8 | 8 | 0.04 | 450 | 14.00 | 309 | 1947 | 6.88 / 523.15 | 5 | 62 |
Average= | 6.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.20 | 77 | 14.19 | 383 | 418 | 0.42 / 509.79 | 5 | 16 |
2 | 7 | 2002.52 | 105 | 11.81 | 1785 | 2213 | 2.63 / 512.01 | 16 | 32 |
3 | 13 | 1701.44 | 36 | 13.01 | 1609 | 754 | 3.39 / 512.76 | 4 | 41 |
4 | 13 | 1603.64 | 36 | 13.07 | 1544 | 726 | 4.11 / 513.49 | 4 | 43 |
5 | 13 | 918.00 | 36 | 13.49 | 1073 | 521 | 4.63 / 514.01 | 4 | 52 |
6 | 13 | 371.00 | 36 | 13.90 | 648 | 324 | 4.96 / 514.33 | 4 | 55 |
7 | 8 | 0.04 | 450 | 14.00 | 308 | 1940 | 6.90 / 516.27 | 5 | 66 |
Average= | 6.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.16 | 77 | 14.18 | 383 | 418 | 0.42 / 502.82 | 5 | 16 |
2 | 7 | 2002.72 | 105 | 11.80 | 1774 | 2198 | 2.62 / 505.02 | 4 | 31 |
3 | 13 | 1805.04 | 36 | 12.95 | 1665 | 776 | 3.39 / 505.80 | 4 | 38 |
4 | 13 | 1493.52 | 36 | 13.18 | 1471 | 698 | 4.09 / 506.50 | 4 | 45 |
5 | 13 | 949.32 | 36 | 13.49 | 1094 | 531 | 4.62 / 507.03 | 4 | 52 |
6 | 13 | 611.28 | 36 | 13.70 | 841 | 415 | 5.04 / 507.44 | 4 | 56 |
7 | 8 | 0.16 | 450 | 14.00 | 307 | 1934 | 6.97 / 509.38 | 5 | 67 |
Average= | 6.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.56 | 77 | 14.18 | 383 | 418 | 0.42 / 495.73 | 5 | 16 |
2 | 7 | 2004.48 | 106 | 11.79 | 1779 | 2223 | 2.64 / 497.95 | 16 | 30 |
3 | 13 | 1908.52 | 36 | 12.85 | 1736 | 803 | 3.44 / 498.75 | 4 | 37 |
4 | 13 | 1382.52 | 36 | 13.24 | 1392 | 663 | 4.11 / 499.42 | 4 | 45 |
5 | 13 | 853.72 | 36 | 13.55 | 1025 | 500 | 4.61 / 499.92 | 4 | 53 |
6 | 13 | 536.84 | 36 | 13.77 | 788 | 391 | 5.00 / 500.31 | 4 | 56 |
7 | 13 | 3.64 | 36 | 14.30 | 320 | 165 | 5.16 / 500.47 | 5 | 46 |
8 | 8 | 0.00 | 450 | 13.96 | 308 | 1935 | 7.10 / 502.41 | 5 | 61 |
Average= | 6.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.64 | 77 | 14.18 | 387 | 423 | 0.42 / 488.65 | 5 | 15 |
2 | 7 | 2003.00 | 106 | 11.82 | 1778 | 2228 | 2.65 / 490.88 | 15 | 32 |
3 | 13 | 1802.36 | 36 | 12.97 | 1669 | 779 | 3.43 / 491.66 | 4 | 39 |
4 | 13 | 1387.04 | 36 | 13.27 | 1393 | 665 | 4.09 / 492.32 | 4 | 45 |
5 | 13 | 962.36 | 36 | 13.51 | 1104 | 537 | 4.63 / 492.86 | 4 | 52 |
6 | 13 | 424.20 | 36 | 13.87 | 689 | 344 | 4.98 / 493.20 | 4 | 55 |
7 | 13 | 16.32 | 36 | 14.27 | 333 | 171 | 5.15 / 493.37 | 5 | 47 |
8 | 8 | 0.20 | 450 | 13.94 | 308 | 1932 | 7.08 / 495.31 | 5 | 61 |
Average= | 6.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.80 | 77 | 14.17 | 393 | 429 | 0.43 / 481.71 | 5 | 17 |
2 | 7 | 2013.60 | 105 | 11.82 | 1785 | 2215 | 2.64 / 483.92 | 17 | 31 |
3 | 13 | 1916.00 | 36 | 12.87 | 1749 | 810 | 3.45 / 484.73 | 4 | 38 |
4 | 13 | 1483.24 | 36 | 13.21 | 1468 | 698 | 4.15 / 485.43 | 4 | 44 |
5 | 13 | 1040.96 | 36 | 13.47 | 1162 | 563 | 4.72 / 485.99 | 4 | 51 |
6 | 13 | 285.36 | 36 | 14.01 | 568 | 286 | 5.00 / 486.28 | 5 | 53 |
7 | 8 | 0.00 | 450 | 14.01 | 309 | 1948 | 6.95 / 488.23 | 5 | 61 |
Average= | 6.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.20 | 77 | 14.20 | 385 | 421 | 0.42 / 474.87 | 5 | 14 |
2 | 7 | 2004.08 | 105 | 11.83 | 1779 | 2210 | 2.63 / 477.08 | 14 | 32 |
3 | 13 | 1812.08 | 36 | 13.00 | 1682 | 787 | 3.42 / 477.87 | 4 | 40 |
4 | 13 | 1293.96 | 36 | 13.33 | 1335 | 641 | 4.06 / 478.51 | 4 | 48 |
5 | 13 | 873.36 | 36 | 13.57 | 1039 | 508 | 4.57 / 479.02 | 4 | 53 |
6 | 13 | 348.80 | 36 | 13.95 | 631 | 317 | 4.88 / 479.34 | 4 | 54 |
7 | 8 | 0.12 | 450 | 14.01 | 308 | 1942 | 6.82 / 481.28 | 5 | 64 |
Average= | 6.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.64 | 77 | 14.16 | 387 | 422 | 0.42 / 468.06 | 5 | 16 |
2 | 7 | 2005.16 | 105 | 11.84 | 1776 | 2208 | 2.63 / 470.27 | 16 | 31 |
3 | 13 | 1808.60 | 36 | 13.01 | 1677 | 785 | 3.42 / 471.05 | 4 | 39 |
4 | 13 | 1493.24 | 36 | 13.23 | 1475 | 703 | 4.12 / 471.76 | 4 | 45 |
5 | 13 | 759.16 | 36 | 13.65 | 963 | 473 | 4.59 / 472.23 | 4 | 54 |
6 | 13 | 243.88 | 36 | 14.05 | 541 | 274 | 4.86 / 472.50 | 5 | 53 |
7 | 8 | 0.08 | 450 | 14.02 | 309 | 1949 | 6.81 / 474.45 | 5 | 64 |
Average= | 6.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.04 | 77 | 14.23 | 375 | 411 | 0.41 / 461.09 | 5 | 16 |
2 | 7 | 2003.72 | 105 | 11.87 | 1775 | 2212 | 2.62 / 463.30 | 16 | 32 |
3 | 13 | 1805.96 | 36 | 13.03 | 1675 | 786 | 3.41 / 464.09 | 4 | 40 |
4 | 13 | 1294.76 | 36 | 13.36 | 1338 | 644 | 4.05 / 464.73 | 4 | 47 |
5 | 13 | 888.40 | 36 | 13.59 | 1053 | 515 | 4.57 / 465.25 | 4 | 53 |
6 | 13 | 251.08 | 36 | 14.06 | 542 | 274 | 4.84 / 465.52 | 5 | 53 |
7 | 13 | 25.80 | 36 | 14.29 | 344 | 177 | 5.02 / 465.70 | 5 | 48 |
8 | 8 | 0.00 | 450 | 13.98 | 308 | 1938 | 6.96 / 467.64 | 5 | 65 |
Average= | 6.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.88 | 77 | 14.20 | 381 | 417 | 0.42 / 454.09 | 5 | 16 |
2 | 7 | 2003.52 | 105 | 11.92 | 1779 | 2227 | 2.64 / 456.31 | 16 | 32 |
3 | 13 | 1706.72 | 36 | 13.12 | 1611 | 761 | 3.40 / 457.08 | 4 | 41 |
4 | 13 | 1514.52 | 36 | 13.26 | 1484 | 708 | 4.11 / 457.78 | 4 | 45 |
5 | 13 | 765.84 | 36 | 13.67 | 962 | 473 | 4.59 / 458.26 | 4 | 55 |
6 | 13 | 343.68 | 36 | 13.98 | 622 | 313 | 4.90 / 458.57 | 4 | 56 |
7 | 13 | 19.00 | 36 | 14.29 | 337 | 173 | 5.07 / 458.74 | 5 | 49 |
8 | 8 | 0.00 | 450 | 13.98 | 308 | 1938 | 7.01 / 460.68 | 5 | 67 |
Average= | 6.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.76 | 77 | 14.21 | 379 | 415 | 0.41 / 447.04 | 5 | 16 |
2 | 7 | 2005.28 | 105 | 11.96 | 1787 | 2244 | 2.66 / 449.29 | 16 | 32 |
3 | 13 | 1913.28 | 36 | 12.95 | 1750 | 816 | 3.47 / 450.10 | 4 | 39 |
4 | 13 | 1280.76 | 36 | 13.39 | 1326 | 639 | 4.11 / 450.74 | 4 | 48 |
5 | 13 | 957.32 | 36 | 13.58 | 1104 | 540 | 4.65 / 451.28 | 4 | 53 |
6 | 13 | 202.88 | 36 | 14.11 | 504 | 256 | 4.91 / 451.54 | 5 | 52 |
7 | 13 | 48.48 | 36 | 14.27 | 363 | 186 | 5.10 / 451.72 | 5 | 48 |
8 | 8 | 0.12 | 450 | 14.02 | 309 | 1949 | 7.05 / 453.67 | 5 | 61 |
Average= | 6.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.68 | 77 | 14.21 | 383 | 419 | 0.42 / 440.05 | 5 | 13 |
2 | 7 | 2004.36 | 105 | 12.01 | 1786 | 2252 | 2.67 / 442.30 | 13 | 33 |
3 | 13 | 1908.88 | 36 | 12.97 | 1748 | 816 | 3.49 / 443.12 | 4 | 40 |
4 | 13 | 1368.68 | 36 | 13.38 | 1387 | 668 | 4.16 / 443.78 | 4 | 48 |
5 | 13 | 942.12 | 36 | 13.60 | 1095 | 536 | 4.69 / 444.32 | 4 | 53 |
6 | 13 | 395.92 | 36 | 13.94 | 674 | 338 | 5.03 / 444.66 | 4 | 57 |
7 | 8 | 0.08 | 450 | 14.01 | 312 | 1967 | 7.00 / 446.63 | 5 | 53 |
Average= | 6.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.88 | 77 | 14.22 | 387 | 424 | 0.42 / 433.00 | 5 | 14 |
2 | 7 | 2003.52 | 105 | 12.05 | 1785 | 2258 | 2.68 / 435.25 | 14 | 34 |
3 | 13 | 1906.04 | 36 | 12.99 | 1744 | 816 | 3.50 / 436.07 | 4 | 40 |
4 | 13 | 1463.04 | 36 | 13.34 | 1454 | 698 | 4.20 / 436.77 | 4 | 47 |
5 | 13 | 914.08 | 36 | 13.61 | 1077 | 528 | 4.72 / 437.30 | 4 | 53 |
6 | 13 | 482.40 | 36 | 13.88 | 747 | 373 | 5.10 / 437.67 | 4 | 57 |
7 | 8 | 0.12 | 450 | 14.01 | 311 | 1961 | 7.06 / 439.63 | 5 | 68 |
Average= | 6.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.56 | 77 | 14.24 | 380 | 417 | 0.42 / 426.11 | 5 | 15 |
2 | 7 | 2004.68 | 105 | 12.09 | 1788 | 2270 | 2.69 / 428.38 | 15 | 34 |
3 | 13 | 1804.80 | 36 | 13.13 | 1676 | 792 | 3.48 / 429.17 | 4 | 42 |
4 | 13 | 1278.56 | 36 | 13.44 | 1327 | 642 | 4.12 / 429.81 | 4 | 48 |
5 | 13 | 856.56 | 36 | 13.66 | 1035 | 509 | 4.63 / 430.32 | 4 | 54 |
6 | 13 | 304.04 | 36 | 14.05 | 588 | 297 | 4.93 / 430.62 | 5 | 55 |
7 | 8 | 0.04 | 450 | 14.04 | 309 | 1952 | 6.88 / 432.57 | 5 | 62 |
Average= | 6.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.20 | 77 | 14.23 | 376 | 412 | 0.41 / 419.10 | 5 | 15 |
2 | 7 | 2013.48 | 105 | 12.14 | 1793 | 2286 | 2.70 / 421.39 | 4 | 34 |
3 | 13 | 1919.84 | 36 | 13.03 | 1753 | 822 | 3.52 / 422.21 | 4 | 41 |
4 | 13 | 1283.44 | 36 | 13.45 | 1329 | 644 | 4.16 / 422.85 | 4 | 48 |
5 | 13 | 859.28 | 36 | 13.68 | 1029 | 507 | 4.67 / 423.36 | 4 | 54 |
6 | 13 | 526.92 | 36 | 13.87 | 777 | 388 | 5.06 / 423.75 | 4 | 57 |
7 | 8 | -0.08 | 450 | 14.04 | 308 | 1946 | 7.00 / 425.69 | 5 | 62 |
Average= | 6.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.92 | 76 | 14.26 | 372 | 403 | 0.40 / 412.27 | 5 | 15 |
2 | 3 | 1015.00 | 1 | 13.25 | 1129 | 15 | 0.42 / 412.28 | 4 | 7 |
3 | 7 | 2012.16 | 106 | 12.19 | 1789 | 2312 | 2.73 / 414.59 | 7 | 33 |
4 | 13 | 1623.16 | 36 | 13.27 | 1557 | 744 | 3.47 / 415.34 | 4 | 43 |
5 | 13 | 1317.32 | 36 | 13.45 | 1355 | 656 | 4.13 / 415.99 | 4 | 48 |
6 | 13 | 776.32 | 36 | 13.73 | 968 | 478 | 4.61 / 416.47 | 4 | 55 |
7 | 13 | 230.48 | 36 | 14.14 | 522 | 266 | 4.87 / 416.74 | 5 | 52 |
8 | 8 | 0.08 | 450 | 14.07 | 308 | 1950 | 6.82 / 418.69 | 5 | 72 |
Average= | 6.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.76 | 76 | 14.25 | 384 | 416 | 0.42 / 405.36 | 5 | 15 |
2 | 7 | 2006.56 | 106 | 12.22 | 1782 | 2308 | 2.72 / 407.67 | 4 | 35 |
3 | 13 | 1917.36 | 36 | 13.06 | 1744 | 820 | 3.54 / 408.49 | 4 | 40 |
4 | 13 | 1390.84 | 36 | 13.43 | 1399 | 676 | 4.22 / 409.16 | 4 | 48 |
5 | 13 | 858.76 | 36 | 13.69 | 1026 | 506 | 4.73 / 409.67 | 4 | 54 |
6 | 13 | 212.68 | 36 | 14.15 | 508 | 259 | 4.98 / 409.93 | 5 | 52 |
7 | 8 | 0.16 | 450 | 14.07 | 306 | 1937 | 6.92 / 411.86 | 5 | 67 |
Average= | 6.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.56 | 75 | 14.26 | 376 | 402 | 0.40 / 398.46 | 5 | 14 |
2 | 3 | 1012.88 | 1 | 13.20 | 1155 | 15 | 0.42 / 398.47 | 4 | 6 |
3 | 7 | 2004.40 | 105 | 12.27 | 1786 | 2301 | 2.72 / 400.77 | 6 | 34 |
4 | 13 | 1801.96 | 36 | 13.19 | 1677 | 796 | 3.51 / 401.57 | 4 | 41 |
5 | 13 | 1187.12 | 36 | 13.53 | 1263 | 615 | 4.13 / 402.18 | 4 | 50 |
6 | 13 | 875.72 | 36 | 13.68 | 1049 | 517 | 4.65 / 402.70 | 4 | 55 |
7 | 13 | 225.28 | 36 | 14.13 | 524 | 267 | 4.91 / 402.97 | 5 | 53 |
8 | 8 | 0.04 | 450 | 14.06 | 312 | 1974 | 6.89 / 404.94 | 5 | 66 |
Average= | 6.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.96 | 75 | 14.27 | 377 | 403 | 0.40 / 391.55 | 5 | 13 |
2 | 7 | 2004.76 | 105 | 12.28 | 1784 | 2300 | 2.70 / 393.85 | 13 | 33 |
3 | 13 | 1904.64 | 36 | 13.08 | 1736 | 817 | 3.52 / 394.67 | 4 | 40 |
4 | 13 | 1265.00 | 36 | 13.50 | 1312 | 638 | 4.16 / 395.30 | 4 | 49 |
5 | 13 | 954.24 | 36 | 13.65 | 1098 | 540 | 4.70 / 395.84 | 4 | 54 |
6 | 13 | 187.88 | 36 | 14.17 | 490 | 250 | 4.95 / 396.09 | 5 | 52 |
7 | 8 | 0.16 | 450 | 14.06 | 310 | 1961 | 6.91 / 398.05 | 5 | 70 |
Average= | 6.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.36 | 75 | 14.27 | 375 | 401 | 0.40 / 384.56 | 5 | 13 |
2 | 7 | 2003.72 | 105 | 12.31 | 1788 | 2311 | 2.71 / 386.87 | 13 | 34 |
3 | 13 | 1702.64 | 36 | 13.27 | 1611 | 770 | 3.48 / 387.64 | 4 | 42 |
4 | 13 | 1287.56 | 36 | 13.50 | 1330 | 646 | 4.13 / 388.29 | 4 | 49 |
5 | 13 | 856.20 | 36 | 13.70 | 1035 | 510 | 4.64 / 388.80 | 4 | 55 |
6 | 13 | 108.36 | 36 | 14.24 | 422 | 216 | 4.86 / 389.01 | 5 | 50 |
7 | 13 | 25.16 | 36 | 14.29 | 346 | 178 | 5.03 / 389.19 | 5 | 48 |
8 | 8 | 0.12 | 450 | 14.01 | 310 | 1954 | 6.99 / 391.15 | 5 | 59 |
Average= | 6.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.52 | 75 | 14.29 | 369 | 395 | 0.40 / 377.40 | 5 | 13 |
2 | 7 | 2012.68 | 105 | 12.34 | 1787 | 2315 | 2.71 / 379.71 | 13 | 34 |
3 | 13 | 1809.00 | 36 | 13.22 | 1676 | 798 | 3.51 / 380.51 | 4 | 41 |
4 | 13 | 1282.88 | 36 | 13.52 | 1326 | 645 | 4.15 / 381.16 | 4 | 49 |
5 | 13 | 857.72 | 36 | 13.71 | 1032 | 509 | 4.66 / 381.67 | 4 | 55 |
6 | 13 | 422.60 | 36 | 13.96 | 701 | 352 | 5.02 / 382.02 | 4 | 58 |
7 | 13 | 17.84 | 36 | 14.33 | 342 | 176 | 5.19 / 382.19 | 5 | 51 |
8 | 8 | -0.20 | 450 | 13.98 | 312 | 1963 | 7.15 / 384.16 | 5 | 71 |
Average= | 6.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.84 | 75 | 14.29 | 376 | 403 | 0.40 / 370.58 | 5 | 13 |
2 | 7 | 2004.80 | 105 | 12.37 | 1781 | 2313 | 2.72 / 372.89 | 4 | 35 |
3 | 13 | 1906.88 | 36 | 13.12 | 1736 | 820 | 3.54 / 373.71 | 4 | 40 |
4 | 13 | 1170.64 | 36 | 13.57 | 1248 | 610 | 4.15 / 374.32 | 4 | 50 |
5 | 13 | 755.48 | 36 | 13.77 | 960 | 476 | 4.62 / 374.80 | 4 | 56 |
6 | 13 | 217.64 | 36 | 14.15 | 515 | 262 | 4.88 / 375.06 | 5 | 54 |
7 | 8 | 0.04 | 450 | 14.07 | 307 | 1944 | 6.83 / 377.00 | 5 | 67 |
Average= | 6.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.04 | 75 | 14.30 | 369 | 396 | 0.40 / 363.58 | 5 | 12 |
2 | 7 | 2004.52 | 106 | 12.39 | 1782 | 2340 | 2.74 / 365.92 | 4 | 35 |
3 | 13 | 1712.72 | 36 | 13.30 | 1616 | 774 | 3.51 / 366.69 | 4 | 43 |
4 | 13 | 1200.12 | 36 | 13.57 | 1272 | 621 | 4.13 / 367.31 | 4 | 51 |
5 | 13 | 767.40 | 36 | 13.77 | 965 | 478 | 4.61 / 367.79 | 4 | 57 |
6 | 13 | 218.84 | 36 | 14.14 | 521 | 265 | 4.87 / 368.06 | 5 | 56 |
7 | 13 | 7.32 | 36 | 14.34 | 329 | 170 | 5.04 / 368.23 | 5 | 51 |
8 | 8 | 0.00 | 450 | 14.02 | 309 | 1949 | 6.99 / 370.17 | 5 | 67 |
Average= | 6.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.28 | 75 | 14.29 | 381 | 408 | 0.41 / 356.52 | 5 | 13 |
2 | 7 | 2002.36 | 105 | 12.42 | 1779 | 2320 | 2.73 / 358.84 | 13 | 35 |
3 | 13 | 1805.68 | 36 | 13.26 | 1680 | 802 | 3.53 / 359.64 | 4 | 43 |
4 | 13 | 1182.72 | 36 | 13.58 | 1261 | 616 | 4.15 / 360.26 | 4 | 51 |
5 | 13 | 853.48 | 36 | 13.73 | 1029 | 509 | 4.66 / 360.77 | 4 | 56 |
6 | 13 | 291.48 | 36 | 14.09 | 584 | 296 | 4.95 / 361.06 | 5 | 57 |
7 | 13 | 19.64 | 36 | 14.34 | 339 | 175 | 5.13 / 361.24 | 5 | 52 |
8 | 8 | 0.04 | 450 | 14.03 | 308 | 1945 | 7.07 / 363.18 | 5 | 57 |
Average= | 6.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.88 | 75 | 14.31 | 381 | 409 | 0.41 / 349.54 | 5 | 12 |
2 | 7 | 2004.28 | 106 | 12.45 | 1787 | 2358 | 2.77 / 351.90 | 4 | 35 |
3 | 13 | 1705.00 | 36 | 13.33 | 1615 | 775 | 3.54 / 352.68 | 4 | 43 |
4 | 13 | 1197.96 | 36 | 13.59 | 1273 | 623 | 4.17 / 353.30 | 4 | 50 |
5 | 13 | 667.36 | 36 | 13.84 | 893 | 445 | 4.61 / 353.74 | 4 | 57 |
6 | 13 | 140.64 | 36 | 14.24 | 452 | 232 | 4.84 / 353.98 | 5 | 52 |
7 | 13 | 31.88 | 36 | 14.32 | 355 | 183 | 5.02 / 354.16 | 5 | 50 |
8 | 8 | -0.04 | 450 | 14.03 | 309 | 1951 | 6.98 / 356.11 | 5 | 60 |
Average= | 6.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.20 | 75 | 14.32 | 381 | 409 | 0.41 / 342.39 | 5 | 13 |
2 | 7 | 2011.12 | 106 | 12.45 | 1799 | 2374 | 2.78 / 344.76 | 13 | 37 |
3 | 13 | 1806.36 | 36 | 13.29 | 1681 | 804 | 3.59 / 345.56 | 4 | 44 |
4 | 13 | 1264.88 | 36 | 13.56 | 1322 | 645 | 4.23 / 346.21 | 4 | 51 |
5 | 13 | 924.00 | 36 | 13.72 | 1086 | 536 | 4.77 / 346.75 | 4 | 56 |
6 | 13 | 156.52 | 36 | 14.22 | 472 | 242 | 5.01 / 346.99 | 5 | 52 |
7 | 13 | 15.08 | 36 | 14.35 | 341 | 176 | 5.19 / 347.16 | 5 | 48 |
8 | 8 | 0.12 | 450 | 14.03 | 312 | 1970 | 7.16 / 349.13 | 5 | 68 |
Average= | 6.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.32 | 75 | 14.33 | 374 | 402 | 0.40 / 335.51 | 5 | 12 |
2 | 7 | 2015.64 | 106 | 12.46 | 1797 | 2373 | 2.78 / 337.88 | 12 | 35 |
3 | 13 | 1715.64 | 36 | 13.34 | 1619 | 778 | 3.55 / 338.66 | 4 | 44 |
4 | 13 | 1284.44 | 36 | 13.56 | 1330 | 649 | 4.20 / 339.31 | 4 | 50 |
5 | 13 | 742.40 | 36 | 13.81 | 948 | 471 | 4.67 / 339.78 | 4 | 57 |
6 | 13 | 115.96 | 36 | 14.29 | 424 | 218 | 4.89 / 340.00 | 5 | 50 |
7 | 8 | 0.04 | 450 | 14.09 | 312 | 1978 | 6.87 / 341.98 | 5 | 67 |
Average= | 6.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.24 | 75 | 14.33 | 380 | 408 | 0.41 / 328.63 | 5 | 10 |
2 | 7 | 2003.12 | 106 | 12.49 | 1789 | 2369 | 2.78 / 331.00 | 4 | 36 |
3 | 13 | 1703.96 | 36 | 13.36 | 1611 | 775 | 3.55 / 331.78 | 4 | 45 |
4 | 13 | 1282.24 | 36 | 13.57 | 1331 | 650 | 4.20 / 332.43 | 4 | 50 |
5 | 13 | 745.92 | 36 | 13.82 | 951 | 473 | 4.68 / 332.90 | 4 | 57 |
6 | 13 | 218.68 | 36 | 14.19 | 515 | 263 | 4.94 / 333.16 | 5 | 53 |
7 | 8 | 0.08 | 450 | 14.11 | 306 | 1943 | 6.88 / 335.11 | 5 | 68 |
Average= | 6.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.24 | 75 | 14.36 | 373 | 402 | 0.40 / 321.78 | 5 | 12 |
2 | 7 | 2015.32 | 105 | 12.51 | 1788 | 2349 | 2.75 / 324.13 | 4 | 36 |
3 | 13 | 1709.44 | 36 | 13.37 | 1614 | 777 | 3.53 / 324.91 | 4 | 44 |
4 | 13 | 1299.84 | 36 | 13.57 | 1338 | 654 | 4.18 / 325.56 | 4 | 50 |
5 | 13 | 757.96 | 36 | 13.82 | 961 | 478 | 4.66 / 326.04 | 4 | 57 |
6 | 13 | 130.16 | 36 | 14.28 | 440 | 226 | 4.89 / 326.26 | 5 | 51 |
7 | 8 | 0.12 | 450 | 14.11 | 309 | 1962 | 6.85 / 328.23 | 5 | 63 |
Average= | 6.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.12 | 75 | 14.36 | 378 | 407 | 0.41 / 314.91 | 5 | 12 |
2 | 7 | 2004.52 | 105 | 12.51 | 1789 | 2350 | 2.76 / 317.26 | 4 | 36 |
3 | 13 | 1701.40 | 36 | 13.37 | 1612 | 776 | 3.53 / 318.04 | 4 | 44 |
4 | 13 | 1385.68 | 36 | 13.54 | 1400 | 682 | 4.22 / 318.72 | 4 | 49 |
5 | 13 | 740.48 | 36 | 13.83 | 948 | 472 | 4.69 / 319.19 | 4 | 57 |
6 | 13 | 101.96 | 36 | 14.31 | 415 | 214 | 4.90 / 319.40 | 5 | 51 |
7 | 8 | 0.00 | 450 | 14.11 | 311 | 1975 | 6.88 / 321.38 | 5 | 68 |
Average= | 6.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.28 | 74 | 14.35 | 381 | 405 | 0.40 / 307.79 | 5 | 14 |
2 | 7 | 2009.80 | 105 | 12.52 | 1786 | 2348 | 2.75 / 310.13 | 4 | 36 |
3 | 13 | 1909.48 | 36 | 13.21 | 1739 | 827 | 3.58 / 310.96 | 4 | 42 |
4 | 13 | 1354.96 | 36 | 13.56 | 1373 | 670 | 4.25 / 311.63 | 4 | 49 |
5 | 13 | 809.84 | 36 | 13.79 | 1002 | 497 | 4.75 / 312.13 | 4 | 57 |
6 | 13 | 175.12 | 36 | 14.24 | 482 | 247 | 4.99 / 312.38 | 5 | 53 |
7 | 13 | 17.40 | 36 | 14.38 | 337 | 174 | 5.17 / 312.55 | 5 | 49 |
8 | 8 | 0.12 | 450 | 14.09 | 308 | 1953 | 7.12 / 314.50 | 5 | 61 |
Average= | 6.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.12 | 74 | 14.33 | 389 | 413 | 0.41 / 300.88 | 5 | 15 |
2 | 7 | 2003.20 | 106 | 12.51 | 1781 | 2362 | 2.77 / 303.24 | 4 | 37 |
3 | 13 | 1705.68 | 36 | 13.37 | 1616 | 778 | 3.55 / 304.02 | 4 | 44 |
4 | 13 | 1298.92 | 36 | 13.57 | 1342 | 656 | 4.21 / 304.67 | 4 | 50 |
5 | 13 | 758.76 | 36 | 13.82 | 963 | 479 | 4.69 / 305.15 | 4 | 56 |
6 | 13 | 204.68 | 36 | 14.21 | 509 | 260 | 4.95 / 305.41 | 5 | 54 |
7 | 8 | -0.04 | 450 | 14.12 | 310 | 1970 | 6.92 / 307.38 | 5 | 68 |
Average= | 6.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.04 | 74 | 14.34 | 379 | 402 | 0.40 / 293.88 | 5 | 14 |
2 | 7 | 2006.08 | 105 | 12.50 | 1794 | 2355 | 2.76 / 296.24 | 4 | 36 |
3 | 13 | 1906.68 | 36 | 13.20 | 1734 | 824 | 3.58 / 297.06 | 4 | 42 |
4 | 13 | 1256.08 | 36 | 13.59 | 1314 | 643 | 4.22 / 297.71 | 4 | 51 |
5 | 13 | 823.52 | 36 | 13.79 | 1012 | 502 | 4.73 / 298.21 | 4 | 57 |
6 | 13 | 170.76 | 36 | 14.25 | 481 | 247 | 4.97 / 298.45 | 5 | 54 |
7 | 8 | 0.00 | 450 | 14.09 | 317 | 2010 | 6.98 / 300.46 | 5 | 68 |
Average= | 6.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.56 | 74 | 14.34 | 389 | 413 | 0.41 / 286.97 | 5 | 16 |
2 | 7 | 2004.48 | 106 | 12.52 | 1787 | 2372 | 2.78 / 289.34 | 4 | 36 |
3 | 13 | 1904.24 | 36 | 13.19 | 1740 | 826 | 3.61 / 290.16 | 4 | 42 |
4 | 13 | 1349.48 | 36 | 13.55 | 1374 | 670 | 4.28 / 290.84 | 4 | 50 |
5 | 13 | 701.16 | 36 | 13.86 | 921 | 460 | 4.74 / 291.29 | 4 | 58 |
6 | 13 | 87.24 | 36 | 14.34 | 405 | 209 | 4.95 / 291.50 | 5 | 52 |
7 | 8 | 0.08 | 450 | 14.09 | 312 | 1978 | 6.93 / 293.48 | 5 | 65 |
Average= | 6.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.72 | 74 | 14.33 | 386 | 409 | 0.41 / 279.91 | 5 | 16 |
2 | 7 | 2009.12 | 106 | 12.53 | 1792 | 2380 | 2.79 / 282.29 | 16 | 36 |
3 | 13 | 1909.60 | 36 | 13.19 | 1749 | 830 | 3.62 / 283.12 | 4 | 42 |
4 | 13 | 1348.40 | 36 | 13.55 | 1376 | 671 | 4.29 / 283.79 | 4 | 50 |
5 | 13 | 907.60 | 36 | 13.76 | 1073 | 532 | 4.82 / 284.32 | 4 | 56 |
6 | 13 | 152.40 | 36 | 14.28 | 465 | 239 | 5.06 / 284.56 | 5 | 54 |
7 | 8 | 0.08 | 450 | 14.10 | 314 | 1992 | 7.05 / 286.55 | 5 | 64 |
Average= | 6.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.64 | 74 | 14.34 | 390 | 414 | 0.41 / 273.02 | 5 | 17 |
2 | 7 | 2009.72 | 105 | 12.55 | 1795 | 2365 | 2.78 / 275.38 | 17 | 36 |
3 | 13 | 1612.16 | 36 | 13.42 | 1554 | 751 | 3.53 / 276.13 | 4 | 46 |
4 | 13 | 1308.40 | 36 | 13.58 | 1351 | 660 | 4.19 / 276.80 | 4 | 51 |
5 | 13 | 760.76 | 36 | 13.85 | 966 | 482 | 4.67 / 277.28 | 4 | 57 |
6 | 13 | 130.40 | 36 | 14.31 | 443 | 228 | 4.90 / 277.51 | 5 | 53 |
7 | 8 | 0.12 | 450 | 14.12 | 314 | 1995 | 6.90 / 279.50 | 5 | 69 |
Average= | 6.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.92 | 74 | 14.35 | 388 | 412 | 0.41 / 266.06 | 5 | 16 |
2 | 7 | 2012.52 | 106 | 12.57 | 1793 | 2389 | 2.80 / 268.45 | 4 | 36 |
3 | 13 | 1816.48 | 36 | 13.33 | 1682 | 807 | 3.61 / 269.26 | 4 | 44 |
4 | 13 | 1170.12 | 36 | 13.65 | 1255 | 617 | 4.22 / 269.88 | 4 | 53 |
5 | 13 | 657.36 | 36 | 13.92 | 887 | 444 | 4.67 / 270.32 | 4 | 58 |
6 | 13 | 212.48 | 36 | 14.24 | 520 | 267 | 4.94 / 270.59 | 4 | 57 |
7 | 8 | 0.00 | 450 | 14.09 | 318 | 2016 | 6.95 / 272.60 | 5 | 79 |
Average= | 6.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.32 | 74 | 14.36 | 390 | 414 | 0.41 / 259.17 | 5 | 19 |
2 | 7 | 2014.40 | 105 | 12.59 | 1796 | 2374 | 2.79 / 261.55 | 19 | 37 |
3 | 13 | 1601.56 | 36 | 13.45 | 1549 | 750 | 3.54 / 262.30 | 4 | 46 |
4 | 13 | 1286.00 | 36 | 13.61 | 1334 | 654 | 4.19 / 262.95 | 4 | 51 |
5 | 13 | 747.32 | 36 | 13.88 | 958 | 479 | 4.67 / 263.43 | 4 | 58 |
6 | 13 | 96.28 | 36 | 14.36 | 415 | 215 | 4.89 / 263.64 | 5 | 53 |
7 | 8 | 0.04 | 450 | 14.13 | 316 | 2009 | 6.89 / 265.65 | 5 | 66 |
Average= | 6.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.80 | 74 | 14.37 | 387 | 412 | 0.41 / 252.16 | 5 | 18 |
2 | 7 | 2003.28 | 106 | 12.63 | 1786 | 2391 | 2.80 / 254.55 | 18 | 37 |
3 | 13 | 1804.52 | 36 | 13.38 | 1680 | 809 | 3.61 / 255.36 | 4 | 44 |
4 | 13 | 1158.04 | 36 | 13.69 | 1245 | 614 | 4.23 / 255.98 | 4 | 53 |
5 | 13 | 629.52 | 36 | 13.95 | 871 | 437 | 4.66 / 256.41 | 4 | 59 |
6 | 13 | 307.68 | 36 | 14.17 | 610 | 311 | 4.97 / 256.73 | 4 | 60 |
7 | 8 | 0.04 | 450 | 14.11 | 320 | 2032 | 7.01 / 258.76 | 5 | 69 |
Average= | 6.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.88 | 74 | 14.38 | 386 | 411 | 0.41 / 245.26 | 5 | 18 |
2 | 7 | 2005.52 | 106 | 12.67 | 1785 | 2397 | 2.81 / 247.65 | 18 | 37 |
3 | 13 | 1608.12 | 36 | 13.50 | 1548 | 752 | 3.56 / 248.41 | 4 | 46 |
4 | 13 | 1200.32 | 36 | 13.70 | 1274 | 628 | 4.19 / 249.04 | 4 | 53 |
5 | 13 | 660.52 | 36 | 13.96 | 891 | 448 | 4.64 / 249.48 | 4 | 59 |
6 | 13 | 133.00 | 36 | 14.35 | 451 | 233 | 4.87 / 249.72 | 5 | 55 |
7 | 8 | 0.00 | 450 | 14.14 | 320 | 2036 | 6.91 / 251.75 | 5 | 67 |
Average= | 6.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.88 | 74 | 14.38 | 392 | 417 | 0.42 / 238.26 | 5 | 19 |
2 | 7 | 2012.36 | 106 | 12.70 | 1792 | 2412 | 2.83 / 240.68 | 19 | 38 |
3 | 13 | 1702.00 | 36 | 13.49 | 1613 | 783 | 3.61 / 241.46 | 4 | 46 |
4 | 13 | 1274.80 | 36 | 13.69 | 1321 | 651 | 4.26 / 242.11 | 4 | 51 |
5 | 13 | 833.84 | 36 | 13.89 | 1019 | 510 | 4.77 / 242.62 | 4 | 57 |
6 | 13 | 92.48 | 36 | 14.39 | 416 | 216 | 4.99 / 242.84 | 5 | 53 |
7 | 8 | 0.12 | 450 | 14.14 | 316 | 2011 | 7.00 / 244.85 | 5 | 65 |
Average= | 6.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.32 | 74 | 14.39 | 389 | 414 | 0.41 / 231.31 | 5 | 19 |
2 | 7 | 2003.12 | 106 | 12.74 | 1786 | 2412 | 2.83 / 233.72 | 19 | 39 |
3 | 13 | 1701.20 | 36 | 13.52 | 1612 | 785 | 3.61 / 234.50 | 4 | 47 |
4 | 13 | 1259.60 | 36 | 13.71 | 1320 | 651 | 4.26 / 235.16 | 4 | 52 |
5 | 13 | 727.40 | 36 | 13.96 | 942 | 473 | 4.74 / 235.63 | 4 | 59 |
6 | 13 | 91.12 | 36 | 14.42 | 408 | 212 | 4.95 / 235.84 | 5 | 53 |
7 | 8 | 0.08 | 450 | 14.15 | 315 | 2006 | 6.95 / 237.85 | 5 | 66 |
Average= | 6.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.28 | 74 | 14.41 | 385 | 411 | 0.41 / 224.30 | 5 | 18 |
2 | 7 | 2005.56 | 105 | 12.78 | 1789 | 2401 | 2.81 / 226.70 | 18 | 37 |
3 | 13 | 1907.64 | 36 | 13.40 | 1744 | 841 | 3.65 / 227.54 | 4 | 43 |
4 | 13 | 1353.28 | 36 | 13.71 | 1376 | 679 | 4.33 / 228.22 | 4 | 51 |
5 | 13 | 684.20 | 36 | 14.01 | 905 | 456 | 4.79 / 228.68 | 4 | 59 |
6 | 13 | 160.64 | 36 | 14.38 | 467 | 242 | 5.03 / 228.92 | 5 | 54 |
7 | 8 | 0.00 | 450 | 14.19 | 309 | 1973 | 7.00 / 230.89 | 5 | 71 |
Average= | 6.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.04 | 73 | 14.41 | 390 | 410 | 0.41 / 217.42 | 5 | 19 |
2 | 3 | 1010.40 | 1 | 14.14 | 1153 | 16 | 0.43 / 217.44 | 4 | 8 |
3 | 7 | 2009.64 | 106 | 12.83 | 1793 | 2438 | 2.87 / 219.88 | 8 | 38 |
4 | 13 | 1701.64 | 36 | 13.58 | 1617 | 791 | 3.66 / 220.67 | 4 | 47 |
5 | 13 | 1156.40 | 36 | 13.81 | 1243 | 618 | 4.27 / 221.29 | 4 | 53 |
6 | 13 | 615.04 | 36 | 14.07 | 851 | 431 | 4.70 / 221.72 | 4 | 59 |
7 | 13 | 80.72 | 36 | 14.47 | 395 | 206 | 4.91 / 221.92 | 5 | 52 |
8 | 8 | 0.16 | 450 | 14.19 | 308 | 1967 | 6.88 / 223.89 | 5 | 68 |
Average= | 6.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.20 | 73 | 14.44 | 385 | 406 | 0.41 / 210.56 | 5 | 19 |
2 | 7 | 2012.20 | 105 | 12.86 | 1795 | 2424 | 2.83 / 212.98 | 4 | 39 |
3 | 13 | 1704.64 | 36 | 13.59 | 1622 | 794 | 3.62 / 213.78 | 4 | 47 |
4 | 13 | 1180.68 | 36 | 13.81 | 1264 | 628 | 4.25 / 214.40 | 4 | 53 |
5 | 13 | 657.64 | 36 | 14.06 | 887 | 449 | 4.70 / 214.85 | 4 | 59 |
6 | 13 | 24.48 | 36 | 14.53 | 347 | 182 | 4.88 / 215.03 | 5 | 50 |
7 | 8 | 0.12 | 450 | 14.19 | 310 | 1980 | 6.86 / 217.01 | 5 | 70 |
Average= | 6.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.08 | 73 | 14.43 | 386 | 407 | 0.41 / 203.73 | 5 | 19 |
2 | 7 | 2013.12 | 105 | 12.89 | 1801 | 2438 | 2.84 / 206.17 | 4 | 39 |
3 | 13 | 1707.04 | 36 | 13.62 | 1620 | 794 | 3.64 / 206.97 | 4 | 47 |
4 | 13 | 1170.04 | 36 | 13.84 | 1249 | 622 | 4.26 / 207.59 | 4 | 53 |
5 | 13 | 536.96 | 36 | 14.14 | 788 | 401 | 4.66 / 207.99 | 4 | 59 |
6 | 13 | 52.52 | 36 | 14.53 | 368 | 192 | 4.85 / 208.18 | 5 | 49 |
7 | 8 | 0.12 | 450 | 14.22 | 308 | 1971 | 6.83 / 210.15 | 5 | 66 |
Average= | 6.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.32 | 73 | 14.44 | 385 | 406 | 0.41 / 196.74 | 5 | 18 |
2 | 7 | 2010.44 | 106 | 12.93 | 1791 | 2455 | 2.86 / 199.19 | 18 | 40 |
3 | 13 | 1705.16 | 36 | 13.64 | 1619 | 795 | 3.66 / 199.99 | 4 | 48 |
4 | 13 | 1179.08 | 36 | 13.84 | 1262 | 629 | 4.28 / 200.62 | 4 | 54 |
5 | 13 | 647.24 | 36 | 14.08 | 883 | 448 | 4.73 / 201.06 | 4 | 60 |
6 | 13 | 212.44 | 36 | 14.40 | 512 | 265 | 5.00 / 201.33 | 5 | 56 |
7 | 8 | 0.12 | 450 | 14.22 | 312 | 1996 | 6.99 / 203.33 | 5 | 70 |
Average= | 6.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.56 | 73 | 14.44 | 390 | 411 | 0.41 / 189.83 | 5 | 19 |
2 | 7 | 2009.52 | 105 | 12.96 | 1792 | 2439 | 2.85 / 192.27 | 19 | 39 |
3 | 13 | 1593.20 | 36 | 13.69 | 1537 | 757 | 3.61 / 193.03 | 4 | 49 |
4 | 13 | 1189.24 | 36 | 13.86 | 1262 | 630 | 4.24 / 193.66 | 4 | 53 |
5 | 13 | 660.80 | 36 | 14.09 | 890 | 451 | 4.69 / 194.11 | 4 | 59 |
6 | 13 | 106.20 | 36 | 14.48 | 422 | 220 | 4.91 / 194.33 | 5 | 53 |
7 | 8 | 0.00 | 450 | 14.21 | 313 | 2001 | 6.91 / 196.33 | 5 | 70 |
Average= | 6.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.84 | 73 | 14.46 | 380 | 401 | 0.40 / 182.94 | 5 | 18 |
2 | 7 | 2014.36 | 105 | 12.98 | 1799 | 2452 | 2.85 / 185.39 | 18 | 39 |
3 | 13 | 1707.84 | 36 | 13.66 | 1613 | 793 | 3.65 / 186.19 | 4 | 48 |
4 | 13 | 1081.76 | 36 | 13.90 | 1189 | 595 | 4.24 / 186.78 | 4 | 54 |
5 | 13 | 654.96 | 36 | 14.10 | 882 | 448 | 4.69 / 187.23 | 4 | 59 |
6 | 13 | 51.12 | 36 | 14.54 | 367 | 192 | 4.88 / 187.42 | 5 | 51 |
7 | 8 | 0.04 | 450 | 14.22 | 313 | 2003 | 6.88 / 189.42 | 5 | 68 |
Average= | 6.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.08 | 73 | 14.47 | 377 | 398 | 0.40 / 175.92 | 5 | 16 |
2 | 7 | 2002.92 | 106 | 13.01 | 1786 | 2463 | 2.86 / 178.39 | 4 | 39 |
3 | 13 | 1795.32 | 36 | 13.62 | 1676 | 822 | 3.68 / 179.21 | 4 | 45 |
4 | 13 | 1242.32 | 36 | 13.84 | 1305 | 650 | 4.33 / 179.86 | 4 | 52 |
5 | 13 | 600.24 | 36 | 14.13 | 846 | 430 | 4.76 / 180.29 | 4 | 59 |
6 | 13 | 162.40 | 36 | 14.45 | 471 | 245 | 5.01 / 180.53 | 5 | 55 |
7 | 8 | 0.12 | 450 | 14.24 | 313 | 2006 | 7.01 / 182.54 | 5 | 66 |
Average= | 6.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.60 | 73 | 14.49 | 370 | 391 | 0.39 / 168.75 | 5 | 16 |
2 | 7 | 2012.68 | 106 | 13.01 | 1803 | 2486 | 2.88 / 171.24 | 4 | 39 |
3 | 13 | 1705.64 | 36 | 13.68 | 1618 | 797 | 3.67 / 172.04 | 4 | 47 |
4 | 13 | 1263.88 | 36 | 13.84 | 1325 | 660 | 4.33 / 172.70 | 4 | 53 |
5 | 13 | 693.24 | 36 | 14.09 | 914 | 464 | 4.80 / 173.16 | 4 | 59 |
6 | 13 | 72.16 | 36 | 14.53 | 390 | 204 | 5.00 / 173.36 | 5 | 51 |
7 | 13 | 18.24 | 36 | 14.50 | 338 | 176 | 5.18 / 173.54 | 5 | 49 |
8 | 8 | 0.20 | 450 | 14.23 | 310 | 1985 | 7.16 / 175.53 | 7 | 80 |
Average= | 6.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.24 | 73 | 14.49 | 371 | 392 | 0.39 / 161.78 | 5 | 14 |
2 | 7 | 2005.68 | 106 | 13.04 | 1795 | 2481 | 2.87 / 164.26 | 4 | 39 |
3 | 13 | 1807.00 | 36 | 13.62 | 1689 | 828 | 3.70 / 165.09 | 4 | 45 |
4 | 13 | 1158.72 | 36 | 13.89 | 1249 | 625 | 4.33 / 165.71 | 4 | 53 |
5 | 13 | 731.12 | 36 | 14.08 | 947 | 480 | 4.81 / 166.19 | 4 | 59 |
6 | 13 | 46.16 | 36 | 14.57 | 362 | 190 | 5.00 / 166.38 | 5 | 48 |
7 | 8 | 0.16 | 450 | 14.26 | 308 | 1976 | 6.97 / 168.36 | 5 | 59 |
Average= | 6.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.52 | 73 | 14.48 | 381 | 403 | 0.40 / 154.88 | 5 | 15 |
2 | 7 | 2012.88 | 105 | 13.06 | 1797 | 2464 | 2.87 / 157.34 | 4 | 40 |
3 | 13 | 1604.64 | 36 | 13.72 | 1552 | 767 | 3.63 / 158.11 | 4 | 48 |
4 | 13 | 1187.48 | 36 | 13.88 | 1265 | 632 | 4.27 / 158.74 | 4 | 53 |
5 | 13 | 733.76 | 36 | 14.08 | 944 | 478 | 4.74 / 159.22 | 4 | 59 |
6 | 13 | 87.40 | 36 | 14.54 | 397 | 208 | 4.95 / 159.42 | 5 | 50 |
7 | 8 | 0.04 | 450 | 14.26 | 306 | 1964 | 6.92 / 161.39 | 5 | 68 |
Average= | 6.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.28 | 73 | 14.49 | 378 | 400 | 0.40 / 147.88 | 5 | 13 |
2 | 7 | 2010.56 | 106 | 13.06 | 1805 | 2499 | 2.90 / 150.38 | 4 | 39 |
3 | 13 | 1805.72 | 36 | 13.63 | 1691 | 830 | 3.73 / 151.21 | 4 | 45 |
4 | 13 | 1161.64 | 36 | 13.89 | 1252 | 626 | 4.35 / 151.84 | 4 | 53 |
5 | 13 | 627.68 | 36 | 14.14 | 867 | 441 | 4.80 / 152.28 | 4 | 59 |
6 | 13 | 93.48 | 36 | 14.53 | 408 | 213 | 5.01 / 152.49 | 5 | 50 |
7 | 8 | 0.00 | 450 | 14.25 | 309 | 1981 | 6.99 / 154.47 | 5 | 63 |
Average= | 6.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.08 | 73 | 14.49 | 374 | 396 | 0.40 / 141.06 | 5 | 14 |
2 | 7 | 2013.04 | 106 | 13.09 | 1807 | 2507 | 2.90 / 143.57 | 4 | 40 |
3 | 13 | 1599.76 | 36 | 13.73 | 1551 | 767 | 3.67 / 144.33 | 4 | 47 |
4 | 13 | 1082.88 | 36 | 13.93 | 1199 | 601 | 4.27 / 144.93 | 4 | 54 |
5 | 13 | 476.20 | 36 | 14.24 | 744 | 381 | 4.65 / 145.31 | 4 | 59 |
6 | 13 | 80.32 | 36 | 14.56 | 389 | 204 | 4.86 / 145.52 | 5 | 50 |
7 | 8 | 0.00 | 450 | 14.26 | 306 | 1964 | 6.82 / 147.48 | 5 | 68 |
Average= | 6.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.20 | 73 | 14.48 | 372 | 393 | 0.39 / 134.14 | 5 | 15 |
2 | 7 | 2005.44 | 106 | 13.11 | 1799 | 2500 | 2.89 / 136.64 | 15 | 40 |
3 | 13 | 1597.20 | 36 | 13.73 | 1548 | 765 | 3.66 / 137.41 | 4 | 49 |
4 | 13 | 1158.36 | 36 | 13.91 | 1252 | 627 | 4.29 / 138.03 | 4 | 54 |
5 | 13 | 620.44 | 36 | 14.15 | 860 | 438 | 4.72 / 138.47 | 4 | 60 |
6 | 13 | 84.16 | 36 | 14.55 | 398 | 208 | 4.93 / 138.68 | 5 | 51 |
7 | 8 | 0.16 | 450 | 14.26 | 309 | 1983 | 6.91 / 140.66 | 5 | 82 |
Average= | 6.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.96 | 72 | 14.48 | 374 | 390 | 0.39 / 127.13 | 5 | 11 |
2 | 7 | 2011.60 | 106 | 13.12 | 1810 | 2517 | 2.91 / 129.65 | 4 | 40 |
3 | 13 | 1704.96 | 36 | 13.70 | 1624 | 801 | 3.71 / 130.45 | 4 | 48 |
4 | 13 | 1158.16 | 36 | 13.91 | 1248 | 625 | 4.33 / 131.07 | 4 | 54 |
5 | 13 | 721.08 | 36 | 14.11 | 938 | 476 | 4.81 / 131.55 | 4 | 59 |
6 | 13 | 69.96 | 36 | 14.55 | 392 | 205 | 5.01 / 131.75 | 5 | 50 |
7 | 8 | 0.08 | 450 | 14.25 | 311 | 1994 | 7.01 / 133.75 | 5 | 67 |
Average= | 6.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.92 | 72 | 14.51 | 377 | 394 | 0.39 / 120.23 | 5 | 13 |
2 | 7 | 2007.20 | 106 | 13.16 | 1803 | 2515 | 2.91 / 122.74 | 13 | 41 |
3 | 13 | 1576.92 | 36 | 13.76 | 1538 | 762 | 3.67 / 123.50 | 4 | 49 |
4 | 13 | 1046.80 | 36 | 13.96 | 1172 | 589 | 4.26 / 124.09 | 4 | 56 |
5 | 13 | 618.36 | 36 | 14.16 | 864 | 440 | 4.70 / 124.53 | 4 | 61 |
6 | 13 | 72.68 | 36 | 14.55 | 395 | 207 | 4.91 / 124.74 | 5 | 53 |
7 | 8 | 0.24 | 450 | 14.24 | 312 | 1999 | 6.91 / 126.74 | 5 | 66 |
Average= | 6.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.68 | 72 | 14.52 | 375 | 392 | 0.39 / 113.36 | 5 | 13 |
2 | 7 | 2014.72 | 106 | 13.17 | 1802 | 2516 | 2.91 / 115.88 | 4 | 40 |
3 | 13 | 1592.40 | 36 | 13.77 | 1542 | 764 | 3.67 / 116.64 | 4 | 49 |
4 | 13 | 982.32 | 36 | 14.00 | 1126 | 568 | 4.24 / 117.21 | 4 | 56 |
5 | 13 | 660.32 | 36 | 14.15 | 890 | 453 | 4.69 / 117.66 | 4 | 60 |
6 | 13 | 47.92 | 36 | 14.59 | 368 | 193 | 4.89 / 117.85 | 5 | 52 |
7 | 8 | 0.00 | 450 | 14.27 | 308 | 1978 | 6.86 / 119.83 | 5 | 66 |
Average= | 6.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.04 | 71 | 14.52 | 376 | 388 | 0.39 / 106.49 | 5 | 13 |
2 | 3 | 1016.64 | 1 | 14.63 | 1166 | 17 | 0.40 / 106.51 | 4 | 25 |
3 | 7 | 2004.68 | 106 | 13.19 | 1800 | 2517 | 2.92 / 109.02 | 25 | 41 |
4 | 13 | 1588.48 | 36 | 13.78 | 1539 | 763 | 3.68 / 109.79 | 4 | 49 |
5 | 13 | 1149.16 | 36 | 13.95 | 1245 | 625 | 4.31 / 110.41 | 4 | 54 |
6 | 13 | 506.04 | 36 | 14.25 | 769 | 394 | 4.70 / 110.81 | 4 | 60 |
7 | 13 | 40.44 | 36 | 14.61 | 357 | 188 | 4.89 / 111.00 | 5 | 51 |
8 | 8 | 0.00 | 450 | 14.28 | 307 | 1973 | 6.87 / 112.97 | 5 | 67 |
Average= | 6.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.64 | 71 | 14.51 | 382 | 394 | 0.39 / 99.65 | 5 | 13 |
2 | 7 | 2012.12 | 106 | 13.21 | 1803 | 2525 | 2.92 / 102.17 | 4 | 41 |
3 | 13 | 1495.68 | 36 | 13.82 | 1484 | 738 | 3.66 / 102.91 | 4 | 50 |
4 | 13 | 980.20 | 36 | 14.02 | 1131 | 571 | 4.23 / 103.48 | 4 | 55 |
5 | 13 | 663.48 | 36 | 14.16 | 896 | 457 | 4.68 / 103.94 | 4 | 60 |
6 | 13 | 24.28 | 36 | 14.63 | 345 | 182 | 4.87 / 104.12 | 5 | 50 |
7 | 8 | 0.08 | 450 | 14.26 | 309 | 1983 | 6.85 / 106.10 | 5 | 59 |
Average= | 6.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.92 | 71 | 14.53 | 377 | 389 | 0.39 / 92.67 | 5 | 12 |
2 | 3 | 1015.04 | 1 | 14.60 | 1169 | 17 | 0.41 / 92.68 | 4 | 21 |
3 | 7 | 2003.40 | 105 | 13.23 | 1803 | 2505 | 2.91 / 95.19 | 21 | 41 |
4 | 13 | 1597.88 | 36 | 13.80 | 1544 | 767 | 3.68 / 95.96 | 4 | 49 |
5 | 13 | 1073.12 | 36 | 13.99 | 1193 | 601 | 4.28 / 96.56 | 4 | 56 |
6 | 13 | 752.36 | 36 | 14.12 | 964 | 490 | 4.77 / 97.05 | 4 | 60 |
7 | 13 | 40.68 | 36 | 14.61 | 365 | 192 | 4.96 / 97.24 | 5 | 51 |
8 | 8 | 0.00 | 450 | 14.27 | 314 | 2016 | 6.98 / 99.25 | 5 | 64 |
Average= | 6.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.04 | 70 | 14.55 | 368 | 375 | 0.37 / 85.42 | 5 | 13 |
2 | 3 | 1015.12 | 1 | 14.64 | 1159 | 17 | 0.39 / 85.43 | 4 | 22 |
3 | 7 | 2004.92 | 105 | 13.25 | 1807 | 2514 | 2.91 / 87.95 | 22 | 40 |
4 | 13 | 1805.84 | 36 | 13.71 | 1687 | 833 | 3.74 / 88.78 | 4 | 46 |
5 | 13 | 1053.64 | 36 | 14.00 | 1177 | 593 | 4.33 / 89.37 | 4 | 55 |
6 | 13 | 843.00 | 36 | 14.07 | 1030 | 522 | 4.85 / 89.90 | 4 | 59 |
7 | 13 | 42.76 | 36 | 14.62 | 367 | 193 | 5.05 / 90.09 | 5 | 52 |
8 | 13 | 26.60 | 36 | 14.50 | 349 | 182 | 5.23 / 90.27 | 5 | 52 |
9 | 8 | 0.04 | 450 | 14.25 | 313 | 2007 | 7.24 / 92.28 | 5 | 67 |
Average= | 6.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.56 | 70 | 14.53 | 373 | 379 | 0.38 / 78.58 | 5 | 12 |
2 | 7 | 2004.40 | 106 | 13.26 | 1797 | 2526 | 2.91 / 81.10 | 4 | 41 |
3 | 13 | 1576.80 | 36 | 13.81 | 1540 | 766 | 3.67 / 81.87 | 4 | 49 |
4 | 13 | 957.60 | 36 | 14.04 | 1111 | 562 | 4.23 / 82.43 | 4 | 57 |
5 | 13 | 561.72 | 36 | 14.22 | 816 | 418 | 4.65 / 82.85 | 4 | 60 |
6 | 13 | 52.12 | 36 | 14.60 | 375 | 197 | 4.85 / 83.05 | 5 | 53 |
7 | 8 | 0.00 | 450 | 14.26 | 311 | 1996 | 6.84 / 85.04 | 5 | 66 |
Average= | 6.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.76 | 70 | 14.53 | 378 | 384 | 0.38 / 71.65 | 5 | 13 |
2 | 7 | 2009.16 | 106 | 13.27 | 1810 | 2546 | 2.93 / 74.20 | 13 | 42 |
3 | 13 | 1698.40 | 36 | 13.78 | 1619 | 803 | 3.73 / 75.00 | 4 | 48 |
4 | 13 | 1143.60 | 36 | 13.98 | 1246 | 627 | 4.36 / 75.63 | 4 | 54 |
5 | 13 | 403.12 | 36 | 14.31 | 693 | 357 | 4.72 / 75.99 | 4 | 60 |
6 | 13 | 50.60 | 36 | 14.60 | 375 | 197 | 4.91 / 76.18 | 5 | 53 |
7 | 8 | -0.04 | 450 | 14.26 | 314 | 2015 | 6.93 / 78.20 | 5 | 60 |
Average= | 6.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.68 | 70 | 14.56 | 373 | 380 | 0.38 / 64.61 | 5 | 12 |
2 | 7 | 2013.08 | 105 | 13.27 | 1813 | 2526 | 2.91 / 67.14 | 12 | 41 |
3 | 13 | 1804.88 | 36 | 13.73 | 1688 | 834 | 3.74 / 67.97 | 4 | 47 |
4 | 13 | 1021.92 | 36 | 14.02 | 1162 | 586 | 4.33 / 68.56 | 4 | 56 |
5 | 13 | 692.76 | 36 | 14.15 | 921 | 469 | 4.80 / 69.03 | 4 | 59 |
6 | 13 | 55.00 | 36 | 14.60 | 386 | 203 | 5.00 / 69.23 | 5 | 54 |
7 | 8 | 0.04 | 450 | 14.24 | 318 | 2038 | 7.04 / 71.27 | 5 | 68 |
Average= | 5.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.84 | 69 | 14.54 | 379 | 380 | 0.38 / 57.71 | 5 | 13 |
2 | 7 | 2002.80 | 106 | 13.29 | 1808 | 2547 | 2.93 / 60.26 | 4 | 41 |
3 | 13 | 1597.04 | 36 | 13.82 | 1548 | 770 | 3.70 / 61.03 | 4 | 48 |
4 | 13 | 1161.76 | 36 | 13.97 | 1254 | 631 | 4.33 / 61.66 | 4 | 54 |
5 | 13 | 422.76 | 36 | 14.31 | 708 | 365 | 4.69 / 62.03 | 4 | 59 |
6 | 13 | 31.52 | 36 | 14.64 | 361 | 190 | 4.88 / 62.22 | 5 | 51 |
7 | 8 | 0.08 | 450 | 14.27 | 314 | 2016 | 6.90 / 64.23 | 5 | 60 |
Average= | 5.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.96 | 68 | 14.56 | 370 | 366 | 0.37 / 50.77 | 5 | 13 |
2 | 3 | 1018.72 | 1 | 14.69 | 1166 | 17 | 0.38 / 50.79 | 4 | 32 |
3 | 7 | 2003.08 | 105 | 13.30 | 1798 | 2511 | 2.89 / 53.30 | 32 | 41 |
4 | 13 | 1686.04 | 36 | 13.79 | 1606 | 797 | 3.69 / 54.09 | 4 | 47 |
5 | 13 | 1050.72 | 36 | 14.01 | 1173 | 592 | 4.28 / 54.69 | 4 | 55 |
6 | 13 | 614.20 | 36 | 14.20 | 858 | 439 | 4.72 / 55.12 | 4 | 60 |
7 | 13 | 38.32 | 36 | 14.63 | 363 | 191 | 4.91 / 55.32 | 5 | 53 |
8 | 8 | 0.04 | 450 | 14.23 | 315 | 2017 | 6.93 / 57.33 | 5 | 64 |
Average= | 5.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.56 | 68 | 14.55 | 387 | 383 | 0.38 / 43.63 | 5 | 13 |
2 | 3 | 1016.80 | 1 | 14.67 | 1166 | 17 | 0.40 / 43.65 | 4 | 29 |
3 | 7 | 2004.00 | 106 | 13.30 | 1797 | 2533 | 2.93 / 46.18 | 29 | 41 |
4 | 13 | 1693.96 | 36 | 13.78 | 1615 | 801 | 3.73 / 46.98 | 4 | 47 |
5 | 13 | 1135.04 | 36 | 13.98 | 1233 | 621 | 4.36 / 47.60 | 4 | 53 |
6 | 13 | 578.28 | 36 | 14.21 | 831 | 425 | 4.78 / 48.03 | 4 | 59 |
7 | 13 | 31.68 | 36 | 14.64 | 362 | 191 | 4.97 / 48.22 | 5 | 52 |
8 | 13 | 15.88 | 36 | 14.49 | 343 | 179 | 5.15 / 48.40 | 5 | 51 |
9 | 8 | -0.16 | 450 | 14.20 | 314 | 2006 | 7.16 / 50.40 | 5 | 80 |
Average= | 5.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.52 | 67 | 14.55 | 382 | 372 | 0.37 / 36.67 | 5 | 12 |
2 | 3 | 1016.72 | 1 | 14.66 | 1164 | 17 | 0.39 / 36.69 | 4 | 28 |
3 | 7 | 1945.12 | 105 | 13.31 | 1762 | 2462 | 2.85 / 39.15 | 28 | 42 |
4 | 13 | 1632.24 | 36 | 13.79 | 1571 | 780 | 3.63 / 39.93 | 4 | 48 |
5 | 13 | 1074.48 | 36 | 13.99 | 1184 | 596 | 4.23 / 40.53 | 4 | 55 |
6 | 13 | 738.44 | 36 | 14.12 | 949 | 482 | 4.71 / 41.01 | 4 | 58 |
7 | 13 | 21.52 | 36 | 14.66 | 350 | 185 | 4.90 / 41.20 | 5 | 51 |
8 | 8 | 0.08 | 450 | 14.23 | 320 | 2049 | 6.94 / 43.25 | 5 | 64 |
Average= | 5.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.64 | 66 | 14.56 | 375 | 360 | 0.36 / 30.13 | 5 | 12 |
2 | 3 | 1021.60 | 1 | 14.72 | 1150 | 17 | 0.38 / 30.15 | 4 | 36 |
3 | 7 | 1741.56 | 106 | 13.38 | 1619 | 2296 | 2.67 / 32.44 | 36 | 43 |
4 | 13 | 1544.68 | 36 | 13.82 | 1506 | 749 | 3.42 / 33.19 | 4 | 49 |
5 | 13 | 933.40 | 36 | 14.04 | 1084 | 548 | 3.97 / 33.74 | 4 | 55 |
6 | 13 | 408.68 | 36 | 14.31 | 688 | 354 | 4.33 / 34.10 | 4 | 58 |
7 | 13 | 21.28 | 36 | 14.66 | 347 | 183 | 4.51 / 34.28 | 5 | 51 |
8 | 8 | 0.16 | 450 | 14.23 | 316 | 2024 | 6.53 / 36.30 | 5 | 67 |
Average= | 5.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.36 | 38 | 14.79 | 341 | 192 | 0.19 / 23.72 | 5 | 9 |
2 | 10 | 1014.56 | 12 | 14.63 | 1096 | 192 | 0.38 / 23.92 | 4 | 31 |
3 | 10 | 1071.00 | 10 | 14.50 | 1140 | 165 | 0.55 / 24.08 | 4 | 34 |
4 | 3 | 1098.48 | 5 | 14.72 | 1185 | 87 | 0.64 / 24.17 | 4 | 49 |
5 | 7 | 1515.56 | 105 | 13.49 | 1431 | 2027 | 2.66 / 26.19 | 49 | 46 |
6 | 13 | 1418.16 | 36 | 13.83 | 1377 | 686 | 3.35 / 26.88 | 4 | 50 |
7 | 13 | 891.56 | 36 | 14.08 | 1019 | 517 | 3.87 / 27.40 | 4 | 56 |
8 | 13 | 265.64 | 36 | 14.45 | 520 | 271 | 4.14 / 27.67 | 4 | 56 |
9 | 13 | 14.92 | 36 | 14.70 | 295 | 156 | 4.29 / 27.82 | 5 | 51 |
10 | 8 | -0.08 | 450 | 14.23 | 304 | 1947 | 6.24 / 29.77 | 5 | 65 |
Average= | 4.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.12 | 67 | 14.60 | 334 | 327 | 0.33 / 18.09 | 5 | 13 |
2 | 7 | 1515.76 | 105 | 13.55 | 1432 | 2037 | 2.36 / 20.13 | 13 | 44 |
3 | 13 | 1317.08 | 36 | 13.94 | 1308 | 656 | 3.02 / 20.79 | 4 | 49 |
4 | 13 | 887.08 | 36 | 14.08 | 1012 | 513 | 3.53 / 21.30 | 4 | 54 |
5 | 13 | 353.60 | 36 | 14.39 | 600 | 311 | 3.84 / 21.61 | 4 | 58 |
6 | 13 | 10.84 | 36 | 14.73 | 292 | 155 | 4.00 / 21.77 | 5 | 51 |
7 | 8 | 0.04 | 450 | 14.27 | 275 | 1766 | 5.77 / 23.53 | 5 | 63 |
Average= | 4.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.16 | 67 | 14.57 | 333 | 325 | 0.33 / 12.61 | 5 | 14 |
2 | 7 | 1517.96 | 105 | 13.53 | 1429 | 2030 | 2.36 / 14.64 | 14 | 44 |
3 | 13 | 1330.32 | 36 | 13.93 | 1313 | 658 | 3.01 / 15.29 | 4 | 49 |
4 | 13 | 803.16 | 36 | 14.10 | 946 | 480 | 3.49 / 15.78 | 4 | 55 |
5 | 13 | 272.92 | 36 | 14.46 | 520 | 271 | 3.76 / 16.05 | 5 | 55 |
6 | 8 | 0.12 | 450 | 14.32 | 267 | 1721 | 5.49 / 17.77 | 5 | 65 |
Average= | 4.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.40 | 38 | 14.66 | 344 | 192 | 0.19 / 6.57 | 5 | 10 |
2 | 10 | 1016.76 | 13 | 14.57 | 1089 | 206 | 0.40 / 6.78 | 4 | 32 |
3 | 10 | 1058.84 | 8 | 14.49 | 1127 | 131 | 0.53 / 6.91 | 4 | 35 |
4 | 10 | 1090.08 | 6 | 14.46 | 1158 | 100 | 0.63 / 7.01 | 4 | 38 |
5 | 3 | 1049.80 | 2 | 14.69 | 1144 | 34 | 0.66 / 7.04 | 4 | 49 |
6 | 7 | 1506.92 | 106 | 13.49 | 1420 | 2031 | 2.69 / 9.07 | 49 | 44 |
7 | 13 | 1311.36 | 36 | 13.89 | 1296 | 648 | 3.34 / 9.72 | 4 | 49 |
8 | 13 | 890.60 | 36 | 14.03 | 1007 | 509 | 3.85 / 10.23 | 4 | 54 |
9 | 13 | 445.24 | 36 | 14.27 | 669 | 344 | 4.19 / 10.57 | 4 | 59 |
10 | 8 | 0.04 | 450 | 14.29 | 266 | 1711 | 5.90 / 12.28 | 5 | 63 |
Average= | 4.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.76 | 38 | 14.78 | 305 | 171 | 0.17 / 2.37 | 5 | 7 |
2 | 10 | 1052.20 | 12 | 14.39 | 1121 | 194 | 0.36 / 2.57 | 4 | 30 |
3 | 10 | 1102.40 | 9 | 14.29 | 1160 | 149 | 0.51 / 2.72 | 4 | 33 |
4 | 3 | 1103.20 | 5 | 14.22 | 1146 | 81 | 0.60 / 2.80 | 4 | 33 |
5 | 7 | 1054.28 | 105 | 13.62 | 1100 | 1573 | 2.17 / 4.37 | 33 | 45 |
6 | 13 | 347.32 | 36 | 14.31 | 582 | 300 | 2.47 / 4.67 | 4 | 54 |
7 | 8 | 0.04 | 450 | 14.25 | 266 | 1706 | 4.17 / 6.38 | 5 | 61 |
Average= | 3.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 67.72 | 38 | 14.56 | 272 | 150 | 0.15 / 0.15 | 5 | 8 |
2 | 7 | 81.76 | 105 | 14.48 | 277 | 421 | 0.57 / 0.57 | 8 | 11 |
3 | 13 | 60.64 | 36 | 14.75 | 262 | 139 | 0.71 / 0.71 | 5 | 13 |
4 | 13 | 15.08 | 36 | 14.79 | 231 | 123 | 0.83 / 0.83 | 5 | 17 |
5 | 8 | 0.28 | 450 | 14.56 | 209 | 1369 | 2.20 / 2.20 | 5 | 35 |
Average= | 2.20 (KJ/cycle) |