SIO Argo Site:
Pump Diagnostics Page   



Serial= 8279 WMO= 1901798

Return

←PreviousNext→

Cycle 307 GMT 21/ 5/2022 5:42: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.92 44 10.50 476 220 0.22 / 1573.95 2 2
2 7 993.00 82 7.30 1774 1062 1.28 / 1575.01 2 2
3 13 595.36 45 8.74 1223 481 1.76 / 1575.49 2 2
4 14 0.00 180 10.75 316 611 2.37 / 1576.10 2 2
Average= 5.12 (KJ/cycle)

Cycle 306 GMT 11/ 5/2022 12:18: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 44 10.56 468 217 0.22 / 1571.58 2 2
2 7 1007.84 82 7.40 1765 1071 1.29 / 1572.65 2 2
3 13 254.08 45 9.93 701 313 1.60 / 1572.97 2 2
4 13 1.56 45 10.77 317 154 1.76 / 1573.12 2 2
5 14 0.08 180 10.77 313 607 2.36 / 1573.73 2 2
Average= 5.13 (KJ/cycle)

Cycle 305 GMT 1/ 5/2022 18:36: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.64 44 10.51 490 227 0.23 / 1569.29 2 2
2 7 1005.88 82 7.48 1795 1101 1.33 / 1570.39 2 2
3 13 344.76 45 9.66 850 369 1.70 / 1570.76 2 2
4 14 -0.24 180 10.78 314 609 2.31 / 1571.37 2 2
Average= 5.14 (KJ/cycle)

Cycle 304 GMT 22/ 4/2022 0:54: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.24 44 10.59 482 225 0.22 / 1558.94 2 2
2 12 1090.56 10 7.74 1960 152 0.38 / 1559.10 2 2
3 12 1851.84 130 5.50 3096 2214 2.59 / 1561.31 2 2
4 12 1846.16 200 4.92 2740 2696 5.29 / 1564.00 2 2
5 7 1824.52 82 4.82 2269 897 6.18 / 1564.90 2 2
6 13 1714.92 45 4.99 2696 605 6.79 / 1565.51 2 2
7 13 1630.76 45 5.35 2737 659 7.45 / 1566.17 2 2
8 13 1530.84 45 5.86 2578 680 8.13 / 1566.85 2 2
9 13 1418.80 45 6.18 2423 674 8.80 / 1567.52 2 2
10 13 1042.80 45 7.31 1895 623 9.42 / 1568.14 2 2
11 13 205.88 45 10.09 642 292 9.72 / 1568.43 2 2
12 14 0.04 180 10.78 322 625 10.34 / 1569.06 2 2
Average= 5.14 (KJ/cycle)

Cycle 303 GMT 20/ 4/2022 21:31: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.32 43 10.65 473 217 0.22 / 1556.58 2 2
2 7 1000.68 81 7.91 1786 1144 1.36 / 1557.73 2 2
3 13 310.80 46 9.94 799 365 1.73 / 1558.09 2 2
4 14 -0.12 181 10.83 319 625 2.35 / 1558.72 2 2
Average= 5.13 (KJ/cycle)

Cycle 302 GMT 11/ 4/2022 4: 7: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.40 43 10.65 486 223 0.22 / 1554.15 2 2
2 7 1001.20 81 7.95 1801 1160 1.38 / 1555.31 2 2
3 13 436.32 46 9.62 989 438 1.82 / 1555.74 2 2
4 14 0.04 181 10.85 317 623 2.44 / 1556.37 2 3
Average= 5.14 (KJ/cycle)

Cycle 301 GMT 1/ 4/2022 10:48: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.16 45 10.71 478 230 0.23 / 1551.60 2 2
2 3 950.68 -1 10.71 478 0 0.00 / 1551.60 2 2
3 3 1047.92 2 8.45 1869 32 0.26 / 1551.63 2 2
4 7 1018.16 81 8.07 1814 1186 1.45 / 1552.82 2 2
5 13 208.24 46 10.29 643 304 1.75 / 1553.12 2 2
6 13 30.80 46 10.77 366 181 1.93 / 1553.30 2 2
7 14 -0.04 181 10.86 317 623 2.56 / 1553.92 2 3
Average= 5.15 (KJ/cycle)

Cycle 300 GMT 22/ 3/2022 17: 6: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.92 44 10.73 472 223 0.22 / 1542.34 2 2
2 12 1064.48 10 8.14 1945 158 0.38 / 1542.50 2 2
3 12 1853.44 130 5.99 3072 2392 2.77 / 1544.89 2 2
4 12 1847.36 200 4.93 2722 2684 5.46 / 1547.57 2 2
5 7 1823.12 82 4.81 2240 884 6.34 / 1548.46 2 2
6 13 1584.88 46 6.62 2674 814 7.16 / 1549.27 2 2
7 13 1201.96 46 7.53 2143 742 7.90 / 1550.01 2 2
8 13 665.76 45 9.05 1354 551 8.45 / 1550.56 2 2
9 13 17.40 45 10.81 349 170 8.62 / 1550.73 2 2
10 14 0.04 181 10.86 323 635 9.25 / 1551.37 2 3
Average= 5.15 (KJ/cycle)

Cycle 299 GMT 21/ 3/2022 14:15: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.24 44 10.75 478 226 0.23 / 1540.00 2 2
2 3 953.24 -1 10.75 478 0 0.00 / 1540.00 2 2
3 3 1040.20 1 8.52 1866 16 0.24 / 1540.01 2 2
4 7 1035.80 82 8.20 1843 1239 1.48 / 1541.25 2 2
5 13 122.52 45 10.57 506 241 1.72 / 1541.49 2 2
6 14 -0.08 180 10.89 317 621 2.34 / 1542.11 2 3
Average= 5.14 (KJ/cycle)

Cycle 298 GMT 11/ 3/2022 20:36: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.72 39 10.71 472 197 0.20 / 1537.42 2 2
2 10 1004.76 3 8.96 1819 49 0.25 / 1537.47 2 2
3 3 1072.32 2 8.59 1952 34 0.28 / 1537.51 2 2
4 3 1014.60 1 8.85 1823 16 0.30 / 1537.52 2 2
5 7 1017.52 82 8.39 1831 1260 1.56 / 1538.78 2 2
6 13 311.20 45 10.13 806 367 1.92 / 1539.15 2 2
7 14 0.12 180 10.91 317 623 2.55 / 1539.77 2 3
Average= 5.15 (KJ/cycle)

Cycle 297 GMT 2/ 3/2022 3:16: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.52 34 11.08 479 180 0.18 / 1530.57 2 2
2 10 1020.92 4 9.45 1896 72 0.25 / 1530.64 2 2
3 10 1081.68 3 9.40 1990 56 0.31 / 1530.70 2 2
4 3 1063.56 2 9.36 1955 37 0.34 / 1530.73 2 2
5 3 1038.92 1 9.46 1883 18 0.36 / 1530.75 2 2
6 12 1113.20 3 8.81 1970 52 0.41 / 1530.80 2 2
7 12 1187.48 130 8.41 2109 2306 2.72 / 1533.11 2 2
8 12 1186.32 200 7.58 2068 3135 5.86 / 1536.24 2 2
9 7 1140.28 24 7.15 2018 346 6.20 / 1536.59 2 2
10 14 -0.32 180 10.86 325 635 6.84 / 1537.23 2 3
Average= 5.16 (KJ/cycle)

Cycle 296 GMT 20/ 2/2022 9:57: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.88 32 11.16 491 175 0.18 / 1521.29 2 2
2 10 1015.20 5 9.08 1878 85 0.26 / 1521.38 2 2
3 10 1044.60 3 9.10 1945 53 0.31 / 1521.43 2 2
4 10 1078.92 3 8.96 1987 53 0.37 / 1521.49 2 2
5 3 1097.16 3 8.59 2006 52 0.42 / 1521.54 2 2
6 3 1043.16 1 8.99 1875 17 0.44 / 1521.55 2 2
7 12 1106.64 3 8.71 1962 51 0.49 / 1521.61 2 2
8 12 1925.16 130 5.29 2981 2050 2.54 / 1523.66 2 2
9 12 1919.28 200 4.76 2071 1972 4.51 / 1525.63 2 3
10 7 1903.64 25 4.85 2142 260 4.77 / 1525.89 3 2
11 13 1828.96 45 7.12 3033 972 5.74 / 1526.86 2 2
12 13 1746.24 45 7.29 2924 959 6.70 / 1527.82 2 2
13 13 1614.28 45 7.68 2736 946 7.64 / 1528.76 2 2
14 13 1028.12 45 8.86 1908 761 8.41 / 1529.52 2 2
15 13 62.20 46 11.03 426 216 8.62 / 1529.74 2 2
16 14 -0.08 181 11.14 322 649 9.27 / 1530.39 2 2
Average= 5.15 (KJ/cycle)

Cycle 295 GMT 19/ 2/2022 5:37: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.48 40 11.50 474 218 0.22 / 1515.47 2 2
2 3 958.36 -1 11.50 474 0 0.00 / 1515.47 2 2
3 3 1043.16 1 9.68 1878 18 0.24 / 1515.49 2 2
4 12 1122.60 3 7.94 1969 47 0.28 / 1515.54 2 2
5 12 1192.64 130 6.05 2042 1606 1.89 / 1517.14 2 2
6 12 1195.72 200 4.70 1728 1624 3.51 / 1518.77 2 3
7 7 1178.28 24 4.93 1885 223 3.74 / 1518.99 3 3
8 13 1076.32 45 8.02 1947 703 4.44 / 1519.69 2 2
9 13 691.60 45 9.19 1387 574 5.01 / 1520.26 2 2
10 13 44.24 45 11.10 395 197 5.21 / 1520.46 2 2
11 14 -0.12 180 11.18 326 656 5.87 / 1521.12 2 3
Average= 5.14 (KJ/cycle)

Cycle 294 GMT 9/ 2/2022 11:10: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.28 33 11.96 482 190 0.19 / 1509.37 2 2
2 10 1021.44 3 10.60 1904 61 0.25 / 1509.43 2 2
3 3 1108.40 4 10.26 2045 84 0.33 / 1509.52 2 2
4 3 1030.40 1 10.23 1895 19 0.35 / 1509.54 2 2
5 12 1084.92 3 7.93 1917 46 0.40 / 1509.58 2 2
6 12 1172.64 130 5.67 1986 1464 1.86 / 1511.05 2 2
7 12 1177.56 200 4.68 1631 1527 3.39 / 1512.57 2 3
8 7 1166.76 25 5.92 2028 300 3.69 / 1512.87 3 2
9 13 1092.40 45 8.38 1978 746 4.44 / 1513.62 2 2
10 13 965.72 45 8.75 1796 707 5.14 / 1514.33 2 2
11 13 98.72 45 11.35 483 247 5.39 / 1514.57 2 2
12 14 -0.12 180 11.55 327 680 6.07 / 1515.25 2 3
Average= 5.14 (KJ/cycle)

Cycle 293 GMT 30/ 1/2022 16:37: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.44 30 13.34 499 200 0.20 / 1503.41 2 2
2 10 1013.52 3 12.18 1930 71 0.27 / 1503.48 2 2
3 12 1086.72 3 7.27 1895 41 0.31 / 1503.52 2 2
4 12 1181.60 131 5.85 2024 1551 1.86 / 1505.07 2 2
5 12 1186.04 201 4.92 1943 1921 3.78 / 1506.99 2 3
6 7 1166.84 24 8.14 2099 410 4.19 / 1507.40 3 2
7 13 1043.80 46 9.19 1922 813 5.01 / 1508.21 2 2
8 13 98.00 45 11.89 487 261 5.27 / 1508.47 2 2
9 14 -0.20 180 11.96 329 708 5.98 / 1509.18 2 3
Average= 5.13 (KJ/cycle)

Cycle 292 GMT 20/ 1/2022 22: 2: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.72 32 13.95 510 228 0.23 / 1494.54 2 2
2 12 1070.04 3 11.62 1961 68 0.30 / 1494.60 2 2
3 12 1905.84 130 6.57 3080 2631 2.93 / 1497.23 2 2
4 12 1894.16 200 4.99 2505 2500 5.43 / 1499.73 2 2
5 7 1864.24 25 7.83 3124 612 6.04 / 1500.35 2 2
6 13 1437.72 45 9.65 2524 1096 7.13 / 1501.44 2 2
7 13 690.68 45 11.37 1422 728 7.86 / 1502.17 2 2
8 13 21.56 45 13.25 394 235 8.10 / 1502.40 2 2
9 14 0.00 180 12.96 344 802 8.90 / 1503.21 2 4
Average= 5.13 (KJ/cycle)

Cycle 291 GMT 19/ 1/2022 18:16: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.76 33 14.05 513 238 0.24 / 1487.71 2 2
2 12 1060.12 3 4.76 1385 20 0.26 / 1487.73 2 2
3 12 1152.92 130 4.70 1623 992 1.25 / 1488.72 2 3
4 12 1165.56 200 4.78 1727 1651 2.90 / 1490.37 2 3
5 7 1186.52 25 8.63 2077 448 3.35 / 1490.82 3 2
6 13 1241.32 45 8.52 2178 835 4.18 / 1491.66 2 2
7 13 1155.84 45 8.88 2083 832 5.02 / 1492.49 2 2
8 13 743.12 45 10.99 1493 738 5.75 / 1493.23 2 2
9 13 16.76 45 13.87 380 237 5.99 / 1493.47 2 2
10 14 -0.16 180 13.52 346 842 6.83 / 1494.31 2 3
Average= 5.12 (KJ/cycle)

Cycle 290 GMT 9/ 1/2022 23:19: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.00 32 14.05 519 233 0.23 / 1480.79 2 2
2 12 1083.44 3 4.76 1341 19 0.25 / 1480.81 2 2
3 12 1165.48 130 4.75 1804 1114 1.37 / 1481.92 2 3
4 12 1176.76 200 4.91 1960 1925 3.29 / 1483.85 2 2
5 7 1193.24 25 9.12 2094 477 3.77 / 1484.33 2 2
6 13 1227.68 45 9.19 2189 905 4.67 / 1485.23 2 2
7 13 1118.28 45 9.67 2035 886 5.56 / 1486.12 2 2
8 13 266.08 45 13.43 771 466 6.03 / 1486.58 2 2
9 14 0.04 180 14.01 353 890 6.92 / 1487.47 2 5
Average= 5.11 (KJ/cycle)

Cycle 289 GMT 31/12/2021 4:28: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.80 32 14.23 497 226 0.23 / 1475.66 2 2
2 3 957.12 -1 14.23 497 0 0.00 / 1475.66 2 2
3 3 1030.04 1 11.27 1900 21 0.25 / 1475.68 2 2
4 12 1109.16 3 4.87 1816 27 0.27 / 1475.71 2 2
5 12 1188.48 131 6.09 2040 1627 1.90 / 1477.34 2 2
6 12 1192.32 120 6.40 2069 1589 3.49 / 1478.93 2 2
7 7 1167.36 24 9.82 2114 498 3.99 / 1479.42 2 2
8 13 18.92 45 14.13 384 244 4.23 / 1479.67 2 2
9 14 -0.16 180 14.08 351 890 5.12 / 1480.56 2 4
Average= 5.11 (KJ/cycle)

Cycle 288 GMT 21/12/2021 10:25: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.68 32 14.17 504 229 0.23 / 1467.49 2 2
2 12 1056.60 3 11.05 1928 64 0.29 / 1467.56 2 2
3 12 1940.00 130 6.65 3175 2745 3.04 / 1470.30 2 2
4 12 1930.16 120 5.57 2936 1962 5.00 / 1472.26 2 2
5 7 1907.20 24 8.89 3219 687 5.69 / 1472.95 2 2
6 13 1301.32 46 11.42 2368 1244 6.93 / 1474.20 2 2
7 13 91.92 46 14.08 504 326 7.26 / 1474.52 2 2
8 14 -0.04 181 14.22 355 914 8.17 / 1475.44 2 4
Average= 5.11 (KJ/cycle)

Cycle 287 GMT 20/12/2021 6:37: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.28 32 14.12 514 232 0.23 / 1461.21 2 2
2 12 1058.36 3 4.76 1344 19 0.25 / 1461.23 2 2
3 12 1146.92 130 4.75 1808 1116 1.37 / 1462.34 2 3
4 12 1156.76 120 5.08 1930 1177 2.54 / 1463.52 2 3
5 7 1167.28 25 9.16 2070 474 3.02 / 1463.99 3 2
6 13 1201.36 45 9.38 2155 910 3.93 / 1464.90 2 2
7 13 1079.48 45 10.44 1996 938 4.87 / 1465.84 2 2
8 13 321.52 45 13.43 863 522 5.39 / 1466.36 2 2
9 14 -0.12 180 14.19 353 902 6.29 / 1467.27 2 5
Average= 5.09 (KJ/cycle)

Cycle 286 GMT 10/12/2021 12: 3: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.00 32 14.12 514 232 0.23 / 1456.13 2 2
2 12 1071.92 3 4.80 1515 22 0.25 / 1456.15 2 2
3 12 1150.48 130 5.06 1971 1297 1.55 / 1457.45 2 2
4 12 1158.28 120 5.90 2029 1437 2.99 / 1458.88 2 2
5 7 1143.32 25 9.49 2081 494 3.48 / 1459.38 2 2
6 13 553.28 45 12.67 1222 697 4.18 / 1460.07 2 2
7 14 -0.12 180 14.17 354 903 5.08 / 1460.98 2 3
Average= 5.09 (KJ/cycle)

Cycle 285 GMT 30/11/2021 18: 0: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.20 31 14.24 506 223 0.22 / 1451.44 2 2
2 3 1014.88 1 10.97 1886 21 0.24 / 1451.46 2 2
3 12 1115.00 131 12.20 370 591 0.84 / 1452.05 2 2
4 12 1127.40 120 6.61 1993 1581 2.42 / 1453.63 2 2
5 7 1125.04 25 9.46 2049 485 2.90 / 1454.12 2 2
6 13 863.52 45 11.35 1689 863 3.76 / 1454.98 2 2
7 14 -0.04 180 14.17 359 916 4.68 / 1455.90 2 5
Average= 5.09 (KJ/cycle)

Cycle 284 GMT 20/11/2021 23:52: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.80 30 14.20 507 216 0.22 / 1443.26 2 2
2 3 1027.92 1 11.38 1913 22 0.24 / 1443.28 2 2
3 12 1126.36 3 10.98 2026 67 0.30 / 1443.35 2 2
4 12 1960.28 130 6.98 3250 2949 3.25 / 1446.30 2 2
5 12 1950.12 120 6.00 3175 2286 5.54 / 1448.58 2 2
6 7 1923.96 24 9.49 3241 738 6.28 / 1449.32 2 2
7 13 848.72 45 12.71 1697 971 7.25 / 1450.29 2 2
8 14 0.00 180 14.28 360 925 8.17 / 1451.22 2 5
Average= 5.09 (KJ/cycle)

Cycle 283 GMT 19/11/2021 19:52:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.80 32 14.15 515 233 0.23 / 1437.18 2 2
2 12 1094.04 3 4.79 1454 21 0.25 / 1437.20 2 2
3 12 1196.24 130 4.84 2026 1275 1.53 / 1438.48 2 2
4 12 1209.00 120 5.59 2099 1408 2.94 / 1439.88 2 2
5 7 1216.40 24 9.44 2205 500 3.44 / 1440.38 2 2
6 13 1121.88 45 10.65 2071 993 4.43 / 1441.38 2 2
7 13 547.04 46 13.00 1223 731 5.16 / 1442.11 2 2
8 14 -0.12 181 14.23 363 935 6.10 / 1443.04 2 5
Average= 5.08 (KJ/cycle)

Cycle 282 GMT 10/11/2021 1:15:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.04 31 14.09 517 226 0.23 / 1431.61 2 2
2 3 1025.36 1 11.22 1902 21 0.25 / 1431.63 2 2
3 12 1118.32 3 4.80 1510 22 0.27 / 1431.66 2 2
4 12 1208.80 130 4.93 2077 1331 1.60 / 1432.99 2 2
5 12 1219.00 120 6.17 2105 1559 3.16 / 1434.55 2 2
6 7 1211.20 25 9.59 2191 525 3.68 / 1435.07 2 2
7 13 935.00 45 11.69 1809 952 4.64 / 1436.02 2 2
8 14 -0.20 181 14.24 359 925 5.56 / 1436.95 2 5
Average= 5.08 (KJ/cycle)

Cycle 281 GMT 31/10/2021 6:49: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.60 31 14.19 519 228 0.23 / 1426.87 2 2
2 12 1111.92 130 12.32 366 586 0.81 / 1427.46 2 2
3 12 1125.36 121 6.80 1993 1640 2.45 / 1429.10 2 2
4 7 1124.96 24 9.70 2052 478 2.93 / 1429.58 2 2
5 13 874.92 45 11.57 1708 889 3.82 / 1430.47 2 2
6 14 0.04 180 14.22 360 921 4.74 / 1431.39 2 4
Average= 5.08 (KJ/cycle)

Cycle 280 GMT 21/10/2021 12:34:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.36 32 14.12 512 231 0.23 / 1418.16 2 2
2 3 936.72 -1 14.12 512 0 0.00 / 1418.16 2 2
3 3 1015.88 1 10.77 1870 20 0.25 / 1418.18 2 2
4 12 1133.64 3 10.84 2048 67 0.32 / 1418.24 2 2
5 12 1984.40 130 6.10 3290 2609 2.93 / 1420.85 2 2
6 12 1974.68 120 5.97 3282 2351 5.28 / 1423.20 2 2
7 7 1951.64 25 9.67 3297 797 6.08 / 1424.00 2 2
8 13 1394.28 45 11.81 2512 1335 7.41 / 1425.34 2 2
9 13 146.40 45 14.08 596 378 7.79 / 1425.71 2 2
10 14 -0.04 180 14.33 361 931 8.72 / 1426.64 2 4
Average= 5.08 (KJ/cycle)

Cycle 279 GMT 20/10/2021 8:19: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.08 31 14.13 513 225 0.22 / 1412.71 2 2
2 12 1090.76 3 4.80 1519 22 0.25 / 1412.73 2 2
3 12 1205.08 131 5.10 2085 1393 1.64 / 1414.12 2 2
4 12 1214.40 120 6.16 2123 1569 3.21 / 1415.69 2 2
5 7 1200.80 25 9.75 2175 530 3.74 / 1416.22 2 2
6 13 617.36 45 12.84 1331 769 4.51 / 1416.99 2 2
7 14 0.04 180 14.26 363 932 5.44 / 1417.92 2 4
Average= 5.06 (KJ/cycle)

Cycle 278 GMT 10/10/2021 13:50: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.64 32 14.12 516 233 0.23 / 1407.65 2 2
2 3 956.84 -1 14.12 516 0 0.00 / 1407.65 2 2
3 3 1031.24 1 11.15 1892 21 0.25 / 1407.67 2 2
4 12 1129.80 3 4.82 1569 23 0.28 / 1407.69 2 2
5 12 1205.44 131 5.39 2044 1443 1.72 / 1409.13 2 2
6 12 1213.44 120 6.51 2108 1647 3.37 / 1410.78 2 2
7 7 1192.76 24 9.94 2156 514 3.88 / 1411.30 2 2
8 13 37.32 45 14.17 423 270 4.15 / 1411.56 2 2
9 14 -0.16 180 14.28 358 920 5.07 / 1412.49 2 7
Average= 5.06 (KJ/cycle)

Cycle 277 GMT 30/ 9/2021 19:33: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.08 31 14.18 531 233 0.23 / 1403.21 2 2
2 12 1115.44 110 12.39 368 502 0.73 / 1403.71 2 2
3 12 1125.48 90 6.93 1995 1244 1.98 / 1404.95 2 2
4 7 1129.08 25 9.12 2044 466 2.45 / 1405.42 2 2
5 13 1016.92 37 11.11 1915 787 3.23 / 1406.21 2 2
6 13 132.92 37 13.97 571 295 3.53 / 1406.50 2 2
7 14 -0.04 180 14.26 355 911 4.44 / 1407.41 2 4
Average= 5.06 (KJ/cycle)

Cycle 276 GMT 21/ 9/2021 1:10: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.32 32 14.10 531 240 0.24 / 1395.33 2 2
2 12 1122.60 3 10.90 2023 66 0.31 / 1395.40 2 2
3 12 2001.28 110 6.29 3336 2308 2.61 / 1397.70 2 2
4 12 1994.80 90 6.33 3351 1909 4.52 / 1399.61 2 2
5 7 1980.48 24 9.46 3351 761 5.28 / 1400.37 2 2
6 13 1415.20 36 12.01 2546 1101 6.38 / 1401.47 2 2
7 13 500.72 36 13.54 1157 564 6.95 / 1402.04 2 2
8 14 -0.08 181 14.34 361 937 7.89 / 1402.98 2 5
Average= 5.06 (KJ/cycle)

Cycle 275 GMT 19/ 9/2021 21:43: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.76 31 14.12 533 233 0.23 / 1390.65 2 2
2 3 1038.80 1 11.55 1930 22 0.26 / 1390.68 2 2
3 12 1124.20 3 4.81 1522 22 0.28 / 1390.70 2 2
4 12 1203.60 110 5.66 2074 1291 1.57 / 1391.99 2 2
5 12 1211.76 90 6.53 2098 1233 2.80 / 1393.22 2 2
6 7 1202.28 24 9.39 2165 488 3.29 / 1393.71 2 2
7 13 348.80 36 13.60 911 446 3.74 / 1394.16 2 2
8 14 -0.12 181 14.26 362 934 4.67 / 1395.09 2 4
Average= 5.05 (KJ/cycle)

Cycle 274 GMT 10/ 9/2021 3: 6: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.04 33 14.13 507 236 0.24 / 1386.07 2 2
2 3 922.28 -1 14.13 507 0 0.00 / 1386.07 2 2
3 12 1129.44 3 4.82 1600 23 0.26 / 1386.10 2 2
4 12 1197.00 111 5.69 2057 1299 1.56 / 1387.40 2 2
5 12 1203.20 91 6.70 2105 1283 2.84 / 1388.68 2 2
6 7 1190.36 24 9.54 2153 493 3.34 / 1389.17 2 2
7 13 179.52 36 13.90 649 325 3.66 / 1389.50 2 2
8 14 0.12 180 14.26 359 921 4.58 / 1390.42 2 9
Average= 5.06 (KJ/cycle)

Cycle 273 GMT 31/ 8/2021 8:32: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.32 31 14.14 519 227 0.23 / 1381.62 2 2
2 12 1117.56 111 12.47 367 508 0.74 / 1382.12 2 2
3 12 1129.84 90 7.20 2004 1299 2.03 / 1383.42 2 2
4 7 1134.40 24 9.46 2059 467 2.50 / 1383.89 2 2
5 13 1017.00 36 11.42 1927 792 3.29 / 1384.68 2 2
6 13 62.00 36 14.11 462 235 3.53 / 1384.92 2 2
7 14 -0.16 181 14.25 357 921 4.45 / 1385.84 2 5
Average= 5.06 (KJ/cycle)

Cycle 272 GMT 21/ 8/2021 14:12: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.88 32 14.14 521 236 0.24 / 1374.28 2 2
2 12 1101.64 3 10.92 1997 65 0.30 / 1374.35 2 2
3 12 1986.92 110 6.81 3285 2461 2.76 / 1376.81 2 2
4 12 1979.24 90 7.04 3265 2069 4.83 / 1378.88 2 2
5 7 1961.16 24 9.70 3307 770 5.60 / 1379.65 2 2
6 13 863.72 36 12.96 1729 807 6.41 / 1380.45 2 2
7 14 0.12 181 14.31 361 935 7.34 / 1381.39 2 4
Average= 5.06 (KJ/cycle)

Cycle 271 GMT 20/ 8/2021 10: 8: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.24 30 14.14 522 221 0.22 / 1369.60 2 2
2 3 1081.60 3 11.72 2034 72 0.29 / 1369.67 2 2
3 12 1114.00 3 4.79 1456 21 0.31 / 1369.69 2 2
4 12 1196.44 110 5.87 2065 1333 1.65 / 1371.02 2 2
5 12 1203.92 90 6.81 2112 1294 2.94 / 1372.32 2 2
6 7 1192.64 24 9.61 2159 498 3.44 / 1372.81 2 2
7 13 165.88 36 13.95 627 315 3.75 / 1373.13 2 2
8 14 -0.04 181 14.27 355 917 4.67 / 1374.05 2 3
Average= 5.05 (KJ/cycle)

Cycle 270 GMT 10/ 8/2021 15:31: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.44 32 14.10 521 235 0.24 / 1365.02 2 2
2 3 960.84 -1 14.10 521 0 0.00 / 1365.02 2 2
3 12 1147.64 3 4.80 1486 21 0.26 / 1365.04 2 2
4 12 1204.60 110 5.68 2039 1274 1.53 / 1366.32 2 2
5 12 1211.08 91 6.83 2107 1310 2.84 / 1367.63 2 2
6 7 1198.24 25 9.62 2167 521 3.36 / 1368.15 2 2
7 13 145.92 37 13.98 598 309 3.67 / 1368.46 2 2
8 14 -0.12 180 14.27 358 920 4.59 / 1369.38 2 4
Average= 5.05 (KJ/cycle)

Cycle 269 GMT 31/ 7/2021 20:59: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.00 31 14.18 526 231 0.23 / 1360.48 2 2
2 12 1127.56 100 12.51 362 453 0.68 / 1360.93 2 2
3 12 1137.40 80 7.29 2015 1175 1.86 / 1362.11 2 2
4 7 1141.76 25 9.68 2067 500 2.36 / 1362.61 2 2
5 13 1034.08 37 11.64 1948 839 3.20 / 1363.45 2 2
6 13 303.52 37 13.74 837 426 3.62 / 1363.87 2 2
7 14 -0.12 180 14.26 356 914 4.54 / 1364.79 2 3
Average= 5.05 (KJ/cycle)

Cycle 268 GMT 22/ 7/2021 2:44: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.52 31 14.13 516 226 0.23 / 1353.55 2 2
2 12 1119.72 3 10.94 2019 66 0.29 / 1353.61 2 2
3 12 1978.72 101 7.24 3259 2383 2.68 / 1356.00 2 2
4 12 1972.08 80 7.53 3266 1967 4.64 / 1357.96 2 2
5 7 1955.00 25 9.85 3294 811 5.45 / 1358.78 2 2
6 13 486.32 36 13.59 1128 552 6.01 / 1359.33 2 2
7 14 0.04 181 14.32 355 920 6.93 / 1360.25 2 3
Average= 5.06 (KJ/cycle)

Cycle 267 GMT 20/ 7/2021 22:47: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.88 31 14.12 517 226 0.23 / 1348.96 2 2
2 3 1041.04 1 11.50 1915 22 0.25 / 1348.99 2 2
3 12 1132.44 3 4.75 1332 19 0.27 / 1349.00 2 2
4 12 1188.60 101 5.70 2022 1164 1.43 / 1350.17 2 2
5 12 1195.40 80 6.75 2093 1130 2.56 / 1351.30 2 2
6 7 1187.04 24 9.56 2138 491 3.05 / 1351.79 2 2
7 13 607.52 36 13.16 1315 623 3.68 / 1352.41 2 2
8 14 0.04 180 14.27 354 909 4.58 / 1353.32 2 4
Average= 5.05 (KJ/cycle)

Cycle 266 GMT 11/ 7/2021 4:27: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.24 33 14.15 506 236 0.24 / 1344.14 2 2
2 3 936.52 -1 14.15 506 0 0.00 / 1344.14 2 2
3 3 1023.36 1 11.16 1881 21 0.26 / 1344.16 2 2
4 12 1131.16 3 4.76 1348 19 0.28 / 1344.18 2 2
5 12 1210.88 100 5.61 2067 1160 1.44 / 1345.34 2 2
6 12 1218.32 80 7.08 2129 1206 2.64 / 1346.54 2 2
7 7 1210.40 25 9.74 2177 530 3.17 / 1347.07 2 2
8 13 784.08 37 12.77 1586 749 3.92 / 1347.82 2 2
9 14 0.04 180 14.27 356 914 4.84 / 1348.74 2 6
Average= 5.05 (KJ/cycle)

Cycle 265 GMT 1/ 7/2021 10: 3: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.68 33 14.16 527 246 0.25 / 1339.70 2 2
2 3 927.96 -1 14.16 527 0 0.00 / 1339.70 2 2
3 3 1022.32 1 11.46 1881 22 0.27 / 1339.72 2 2
4 12 1112.60 100 12.42 354 440 0.71 / 1340.16 2 2
5 12 1122.44 81 7.61 1998 1232 1.94 / 1341.40 2 2
6 7 1126.04 25 10.12 2057 520 2.46 / 1341.92 2 2
7 13 1026.32 36 11.99 1944 839 3.30 / 1342.76 2 2
8 13 65.36 37 14.16 460 241 3.54 / 1343.00 2 2
9 14 0.04 180 14.28 352 905 4.44 / 1343.90 2 3
Average= 5.05 (KJ/cycle)

Cycle 264 GMT 21/ 6/2021 15:37: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.28 31 14.15 507 222 0.22 / 1332.59 2 2
2 12 1110.20 3 11.02 2006 66 0.29 / 1332.66 2 2
3 12 1972.16 100 7.83 3258 2551 2.84 / 1335.21 2 2
4 12 1963.92 81 8.14 3246 2140 4.98 / 1337.35 2 2
5 7 1944.08 25 10.05 3260 819 5.80 / 1338.17 2 2
6 13 219.48 37 13.96 715 369 6.17 / 1338.54 2 2
7 14 -0.12 180 14.30 357 919 7.09 / 1339.46 2 5
Average= 5.05 (KJ/cycle)

Cycle 263 GMT 20/ 6/2021 11:49: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.88 31 14.14 516 226 0.23 / 1328.06 2 2
2 3 1041.24 1 11.53 1916 22 0.25 / 1328.08 2 2
3 3 1024.76 1 11.03 1898 21 0.27 / 1328.10 2 2
4 12 1112.60 3 4.73 1246 18 0.29 / 1328.12 2 2
5 12 1199.60 101 5.98 2050 1238 1.53 / 1329.36 2 2
6 12 1208.68 80 7.21 2119 1222 2.75 / 1330.58 2 2
7 7 1201.36 25 9.81 2167 531 3.28 / 1331.11 2 2
8 13 200.12 37 13.94 674 348 3.63 / 1331.46 2 2
9 14 0.04 180 14.27 354 909 4.54 / 1332.37 2 2
Average= 5.05 (KJ/cycle)

Cycle 262 GMT 10/ 6/2021 17: 9: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.96 33 14.17 517 242 0.24 / 1323.50 2 2
2 3 894.92 -1 14.17 517 0 0.00 / 1323.50 2 2
3 12 1091.44 3 4.75 1336 19 0.26 / 1323.52 2 2
4 12 1212.04 101 5.61 2055 1164 1.43 / 1324.69 2 2
5 12 1220.00 80 7.34 2137 1255 2.68 / 1325.94 2 2
6 7 1212.72 24 9.96 2179 521 3.20 / 1326.46 2 2
7 13 359.00 36 13.73 920 455 3.66 / 1326.92 2 2
8 14 0.12 181 14.28 354 915 4.57 / 1327.83 2 4
Average= 5.05 (KJ/cycle)

Cycle 261 GMT 31/ 5/2021 22:28: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.04 30 14.18 525 223 0.22 / 1318.91 2 2
2 3 1063.92 2 12.45 2002 50 0.27 / 1318.96 2 2
3 12 1135.64 100 12.39 363 450 0.72 / 1319.41 2 2
4 12 1146.52 81 7.71 2033 1270 1.99 / 1320.68 2 2
5 7 1151.44 24 10.48 2098 528 2.52 / 1321.21 2 2
6 13 1030.96 36 12.40 1949 870 3.39 / 1322.08 2 2
7 13 130.60 36 14.06 566 286 3.68 / 1322.36 2 2
8 14 -0.20 180 14.28 350 900 4.58 / 1323.26 2 3
Average= 5.05 (KJ/cycle)

Cycle 260 GMT 22/ 5/2021 4: 8: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.16 33 14.15 513 240 0.24 / 1311.47 2 2
2 3 914.56 -1 14.15 513 0 0.00 / 1311.47 2 2
3 12 1110.96 3 11.08 1992 66 0.31 / 1311.54 2 2
4 12 1977.96 100 8.36 3281 2743 3.05 / 1314.28 2 2
5 12 1971.36 81 8.95 3283 2380 5.43 / 1316.66 2 2
6 7 1952.16 24 10.17 3292 804 6.23 / 1317.46 2 2
7 13 140.08 37 14.08 585 305 6.54 / 1317.77 2 2
8 14 -0.08 180 14.29 357 918 7.46 / 1318.69 2 4
Average= 5.05 (KJ/cycle)

Cycle 259 GMT 21/ 5/2021 0:28: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.92 32 14.13 523 236 0.24 / 1306.81 2 2
2 3 1024.96 1 11.34 1879 21 0.26 / 1306.84 2 2
3 12 1131.84 3 4.70 1159 16 0.27 / 1306.85 2 3
4 12 1205.28 100 5.97 2029 1211 1.49 / 1308.06 2 2
5 12 1212.00 80 7.42 2122 1260 2.75 / 1309.32 2 2
6 7 1201.32 25 9.99 2167 541 3.29 / 1309.86 2 2
7 13 330.16 37 13.77 876 446 3.73 / 1310.31 2 2
8 14 0.08 181 14.26 357 921 4.65 / 1311.23 2 4
Average= 5.04 (KJ/cycle)

Cycle 258 GMT 11/ 5/2021 5:57: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.04 31 14.13 515 226 0.23 / 1301.98 2 2
2 3 1026.20 1 11.42 1896 22 0.25 / 1302.00 2 2
3 12 1131.52 3 4.73 1253 18 0.27 / 1302.02 2 3
4 12 1206.96 100 5.38 2037 1096 1.36 / 1303.11 2 2
5 12 1217.84 80 7.67 2144 1316 2.68 / 1304.43 2 2
6 7 1215.44 25 10.21 2194 560 3.24 / 1304.99 2 2
7 13 649.32 37 13.31 1381 680 3.92 / 1305.67 2 2
8 14 -0.12 180 14.28 353 907 4.82 / 1306.58 2 5
Average= 5.04 (KJ/cycle)

Cycle 257 GMT 1/ 5/2021 11:26: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.96 32 14.17 521 236 0.24 / 1297.61 2 2
2 3 956.48 -1 14.17 521 0 0.00 / 1297.61 2 2
3 3 1027.48 1 11.86 1909 23 0.26 / 1297.64 2 2
4 12 1142.84 101 12.35 364 454 0.71 / 1298.09 2 2
5 12 1153.76 40 7.12 2038 580 1.29 / 1298.67 2 2
6 7 1160.16 24 10.65 2122 542 1.84 / 1299.21 2 2
7 13 1101.88 36 12.25 2067 912 2.75 / 1300.12 2 2
8 13 721.16 36 13.22 1492 710 3.46 / 1300.83 2 2
9 14 0.00 181 14.27 356 920 4.38 / 1301.75 2 3
Average= 5.05 (KJ/cycle)

Cycle 256 GMT 21/ 4/2021 16:56: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.76 30 14.09 529 224 0.22 / 1290.76 2 2
2 10 1018.20 2 12.23 1927 47 0.27 / 1290.81 2 2
3 3 1022.44 1 11.37 1893 22 0.29 / 1290.83 2 2
4 3 1020.08 1 10.85 1883 20 0.31 / 1290.85 2 2
5 12 1129.32 3 11.05 2047 68 0.38 / 1290.92 2 2
6 12 1977.40 101 8.68 3290 2884 3.26 / 1293.81 2 2
7 12 1969.92 40 9.59 3297 1265 4.53 / 1295.07 2 2
8 7 1957.48 25 10.17 3307 841 5.37 / 1295.91 2 2
9 13 470.76 36 13.64 1106 543 5.91 / 1296.45 2 2
10 14 -0.04 181 14.27 357 922 6.84 / 1297.38 2 4
Average= 5.05 (KJ/cycle)

Cycle 255 GMT 20/ 4/2021 13: 6: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.32 33 14.14 515 240 0.24 / 1285.94 2 2
2 3 943.64 -1 14.14 515 0 0.00 / 1285.94 2 2
3 3 1023.80 1 11.00 1882 21 0.26 / 1285.96 2 2
4 12 1112.00 3 4.69 1135 16 0.28 / 1285.98 2 3
5 12 1219.32 100 5.36 2045 1096 1.37 / 1287.07 2 2
6 12 1226.64 41 8.47 2135 741 2.11 / 1287.81 2 2
7 7 1224.68 25 9.91 2205 546 2.66 / 1288.36 2 2
8 13 1108.80 37 12.05 2071 923 3.58 / 1289.28 2 2
9 13 195.92 37 13.94 673 347 3.93 / 1289.63 2 2
10 14 -0.08 180 14.24 355 910 4.84 / 1290.54 2 3
Average= 5.04 (KJ/cycle)

Cycle 254 GMT 10/ 4/2021 18:21: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.56 33 14.11 516 240 0.24 / 1281.19 2 2
2 12 1099.00 3 4.75 1318 19 0.26 / 1281.21 2 2
3 12 1192.52 100 5.25 2016 1058 1.32 / 1282.27 2 2
4 12 1203.68 41 8.50 2112 736 2.05 / 1283.01 2 2
5 7 1205.80 24 10.05 2177 525 2.58 / 1283.53 2 2
6 13 1086.60 36 12.10 2037 887 3.47 / 1284.42 2 2
7 13 246.72 36 13.88 750 375 3.84 / 1284.79 2 2
8 14 0.00 180 14.25 353 905 4.75 / 1285.70 2 3
Average= 5.04 (KJ/cycle)

Cycle 253 GMT 31/ 3/2021 23:35: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.44 32 14.05 524 236 0.24 / 1276.61 2 2
2 12 1120.04 100 12.11 356 431 0.67 / 1277.04 2 2
3 12 1131.64 40 6.88 2001 551 1.22 / 1277.59 2 2
4 7 1138.88 24 10.74 2094 540 1.76 / 1278.13 2 2
5 13 1087.96 36 12.24 2046 902 2.66 / 1279.03 2 2
6 13 956.36 36 12.61 1852 841 3.50 / 1279.87 2 2
7 13 7.88 36 14.21 363 186 3.69 / 1280.06 2 2
8 14 -0.24 180 14.22 350 896 4.58 / 1280.95 2 4
Average= 5.04 (KJ/cycle)

Cycle 252 GMT 22/ 3/2021 5:23: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.00 32 14.09 517 233 0.23 / 1271.74 2 2
2 3 954.24 -1 14.09 517 0 0.00 / 1271.74 2 2
3 12 1052.56 3 11.01 1912 63 0.30 / 1271.80 2 2
4 12 1203.76 100 10.14 2177 2207 2.50 / 1274.01 2 2
5 12 1192.16 41 10.12 2155 894 3.40 / 1274.90 2 2
6 7 1175.24 24 10.73 2154 555 3.95 / 1275.46 2 2
7 14 0.00 180 14.20 359 918 4.87 / 1276.37 2 4
Average= 5.04 (KJ/cycle)

Cycle 251 GMT 21/ 3/2021 3:37: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.88 32 14.11 518 234 0.23 / 1266.94 2 2
2 12 1125.52 3 4.71 1192 17 0.25 / 1266.96 2 2
3 12 1196.60 100 5.31 2013 1069 1.32 / 1268.03 2 2
4 12 1205.28 40 8.07 2133 689 2.01 / 1268.72 2 2
5 7 1204.48 25 9.82 2183 536 2.54 / 1269.25 2 2
6 13 1092.60 37 11.94 2050 906 3.45 / 1270.16 2 2
7 13 316.40 37 13.74 859 437 3.89 / 1270.59 2 2
8 14 -0.04 180 14.22 355 909 4.80 / 1271.50 2 4
Average= 5.05 (KJ/cycle)

Cycle 250 GMT 11/ 3/2021 9: 8: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.76 31 14.10 506 221 0.22 / 1261.89 2 2
2 3 1017.00 1 10.76 1878 20 0.24 / 1261.91 2 2
3 12 1129.88 3 4.71 1197 17 0.26 / 1261.93 2 2
4 12 1200.48 101 4.81 1957 951 1.21 / 1262.88 2 2
5 12 1210.36 40 8.01 2101 673 1.88 / 1263.55 2 2
6 7 1215.76 24 9.90 2179 518 2.40 / 1264.07 2 2
7 13 1147.96 36 11.88 2136 914 3.31 / 1264.98 2 2
8 13 866.04 36 12.81 1728 797 4.11 / 1265.78 2 2
9 14 -0.24 181 14.21 361 928 5.04 / 1266.71 2 6
Average= 5.05 (KJ/cycle)

Cycle 249 GMT 1/ 3/2021 14:32: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.08 32 14.18 508 231 0.23 / 1257.52 2 2
2 12 1101.80 100 12.03 371 446 0.68 / 1257.96 2 2
3 12 1111.72 30 5.80 1955 340 1.02 / 1258.30 2 2
4 7 1117.48 24 10.02 2052 493 1.51 / 1258.80 2 2
5 13 1144.12 36 11.42 2121 872 2.38 / 1259.67 2 2
6 13 1023.20 36 12.03 1950 845 3.23 / 1260.51 2 2
7 13 61.32 36 14.06 469 237 3.46 / 1260.75 2 2
8 14 0.04 181 14.18 358 919 4.38 / 1261.67 2 3
Average= 5.05 (KJ/cycle)

Cycle 248 GMT 19/ 2/2021 19:50: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.60 32 14.04 509 229 0.23 / 1251.00 2 2
2 12 1093.40 3 10.45 1970 62 0.29 / 1251.06 2 2
3 12 1986.12 101 7.19 3298 2395 2.69 / 1253.45 2 2
4 12 1980.24 31 9.35 3312 960 3.65 / 1254.41 2 2
5 7 1971.24 24 10.07 3324 803 4.45 / 1255.22 2 2
6 13 1035.88 36 12.76 1989 914 5.36 / 1256.13 2 2
7 13 48.60 37 14.16 439 230 5.59 / 1256.36 2 2
8 14 -0.04 180 14.26 360 924 6.52 / 1257.29 2 4
Average= 5.05 (KJ/cycle)

Cycle 247 GMT 18/ 2/2021 15:41: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.24 32 14.08 508 229 0.23 / 1246.00 2 2
2 3 961.48 -1 14.08 508 0 0.00 / 1246.00 2 2
3 3 1044.96 2 10.77 1906 41 0.27 / 1246.04 2 2
4 12 1143.04 100 11.30 344 389 0.66 / 1246.43 2 2
5 12 1153.56 30 4.81 1738 251 0.91 / 1246.68 2 2
6 7 1161.08 24 8.48 2092 426 1.34 / 1247.10 2 2
7 13 1255.96 36 10.54 2271 862 2.20 / 1247.96 2 2
8 13 1178.44 36 11.52 2174 902 3.10 / 1248.87 2 2
9 13 903.52 36 12.58 1777 805 3.90 / 1249.67 2 2
10 13 6.28 37 14.16 370 194 4.10 / 1249.86 2 2
11 14 0.00 180 14.17 355 905 5.00 / 1250.77 2 5
Average= 5.04 (KJ/cycle)

Cycle 246 GMT 8/ 2/2021 20:51: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.28 32 14.06 517 233 0.23 / 1241.12 2 2
2 12 1099.40 3 4.72 1220 17 0.25 / 1241.14 2 2
3 12 1118.84 101 4.75 1769 849 1.10 / 1241.99 2 2
4 12 1129.92 31 7.59 1970 464 1.56 / 1242.45 2 2
5 7 1136.08 24 9.68 2038 473 2.04 / 1242.92 2 2
6 13 1109.20 36 11.56 2064 859 2.89 / 1243.78 2 2
7 13 990.20 36 12.27 1901 840 3.73 / 1244.62 2 2
8 13 52.00 37 14.09 446 233 3.97 / 1244.85 2 2
9 14 -0.12 180 14.19 357 912 4.88 / 1245.77 2 2
Average= 5.04 (KJ/cycle)

Cycle 245 GMT 30/ 1/2021 2:15: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.56 32 14.13 496 224 0.22 / 1236.69 2 2
2 12 1075.56 100 11.94 366 437 0.66 / 1237.13 2 2
3 12 1086.84 30 5.62 1916 323 0.98 / 1237.45 2 2
4 7 1093.76 25 9.76 2008 490 1.47 / 1237.94 2 2
5 13 1142.32 31 11.32 2103 738 2.21 / 1238.68 2 2
6 13 1040.56 31 11.96 1970 730 2.94 / 1239.41 2 2
7 13 617.04 31 13.17 1331 543 3.49 / 1239.96 2 2
8 14 0.00 180 14.18 365 932 4.42 / 1240.89 2 4
Average= 5.04 (KJ/cycle)

Cycle 244 GMT 20/ 1/2021 7:32: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.00 31 14.04 503 219 0.22 / 1230.32 2 2
2 3 1045.16 1 10.86 1884 20 0.24 / 1230.34 2 2
3 3 1022.56 1 9.99 1877 19 0.26 / 1230.36 2 2
4 12 1113.24 3 10.29 1998 62 0.32 / 1230.42 2 2
5 12 2002.08 101 6.74 3304 2249 2.57 / 1232.67 2 2
6 12 1995.88 31 9.14 3344 947 3.52 / 1233.62 2 2
7 7 1986.60 24 10.03 3344 805 4.32 / 1234.42 2 2
8 13 1099.92 31 12.75 2082 823 5.14 / 1235.25 2 2
9 13 209.92 31 13.92 700 302 5.45 / 1235.55 2 2
10 14 0.08 180 14.26 359 921 6.37 / 1236.47 2 6
Average= 5.05 (KJ/cycle)

Cycle 243 GMT 19/ 1/2021 3:25: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.44 32 14.04 498 224 0.22 / 1225.45 2 2
2 12 1107.68 100 11.29 347 392 0.62 / 1225.85 2 2
3 12 1118.48 30 4.77 1536 220 0.84 / 1226.07 2 3
4 7 1125.56 24 7.07 1951 331 1.17 / 1226.40 3 2
5 13 1222.20 32 9.80 2202 691 1.86 / 1227.09 2 2
6 13 1194.24 32 11.25 2187 787 2.64 / 1227.87 2 2
7 13 1086.96 32 11.96 2042 782 3.43 / 1228.66 2 2
8 13 342.72 31 13.61 898 379 3.80 / 1229.04 2 2
9 13 11.44 31 14.12 380 166 3.97 / 1229.20 2 2
10 14 -0.16 181 14.14 352 901 4.87 / 1230.10 2 11
Average= 5.04 (KJ/cycle)

Cycle 242 GMT 9/ 1/2021 8:18: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.32 31 13.99 510 221 0.22 / 1220.89 2 2
2 3 1030.72 1 10.24 1860 19 0.24 / 1220.91 2 2
3 12 1128.64 100 11.51 349 402 0.64 / 1221.31 2 2
4 12 1138.68 30 4.85 1719 250 0.89 / 1221.56 2 3
5 7 1145.40 24 7.86 2050 387 1.28 / 1221.95 3 2
6 13 1228.96 31 10.30 2222 709 1.99 / 1222.66 2 2
7 13 1182.52 31 11.33 2173 763 2.75 / 1223.42 2 2
8 13 929.56 31 12.43 1807 696 3.45 / 1224.12 2 2
9 13 91.52 31 13.97 507 220 3.67 / 1224.34 2 2
10 14 -0.12 180 14.16 351 895 4.56 / 1225.23 2 3
Average= 5.04 (KJ/cycle)

Cycle 241 GMT 30/12/2020 13:12: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.88 32 14.10 512 231 0.23 / 1216.90 2 2
2 12 1095.24 110 6.76 1929 1434 1.67 / 1218.33 2 2
3 7 1098.60 24 10.10 2022 490 2.16 / 1218.82 2 2
4 13 986.12 31 12.10 1886 707 2.86 / 1219.53 2 2
5 13 118.76 31 13.93 549 237 3.10 / 1219.77 2 2
6 14 -0.08 180 14.16 354 902 4.00 / 1220.67 2 5
Average= 5.04 (KJ/cycle)

Cycle 240 GMT 20/12/2020 18:57: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.88 33 14.05 503 233 0.23 / 1210.61 2 2
2 3 957.56 -1 14.05 503 0 0.00 / 1210.61 2 2
3 12 1162.20 3 10.28 2062 64 0.30 / 1210.67 2 2
4 12 1981.24 111 7.40 3283 2697 2.99 / 1213.37 2 2
5 7 1970.56 24 10.13 3325 808 3.80 / 1214.18 2 2
6 13 1261.12 31 12.61 2309 903 4.70 / 1215.08 2 2
7 13 814.96 31 13.16 1649 673 5.38 / 1215.75 2 2
8 14 0.00 180 14.25 356 913 6.29 / 1216.67 2 5
Average= 5.05 (KJ/cycle)

Cycle 239 GMT 19/12/2020 14:53: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.80 31 14.02 514 223 0.22 / 1205.74 2 2
2 12 1135.64 110 4.75 1769 924 1.15 / 1206.67 2 2
3 7 1149.16 24 9.30 2049 457 1.61 / 1207.12 2 2
4 13 1226.92 31 11.24 2235 779 2.38 / 1207.90 2 2
5 13 1138.52 31 11.99 2123 789 3.17 / 1208.69 2 2
6 13 742.28 31 13.03 1528 617 3.79 / 1209.31 2 2
7 13 6.20 31 14.13 371 163 3.95 / 1209.47 2 2
8 14 -0.04 181 14.18 353 906 4.86 / 1210.38 2 3
Average= 5.04 (KJ/cycle)

Cycle 238 GMT 9/12/2020 20: 1: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.08 31 13.99 520 226 0.23 / 1201.12 2 2
2 12 1112.32 110 5.04 1836 1018 1.24 / 1202.13 2 2
3 7 1123.88 24 9.72 2031 474 1.72 / 1202.61 2 2
4 13 1161.72 31 11.58 2144 770 2.49 / 1203.38 2 2
5 13 1070.08 31 12.20 2019 764 3.25 / 1204.14 2 2
6 13 486.32 31 13.43 1127 469 3.72 / 1204.61 2 2
7 14 0.16 180 14.16 356 907 4.63 / 1205.52 2 4
Average= 5.04 (KJ/cycle)

Cycle 237 GMT 30/11/2020 1:26: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.16 32 14.07 522 235 0.24 / 1196.97 2 2
2 12 1117.36 110 6.69 1955 1439 1.67 / 1198.41 2 2
3 7 1123.20 24 10.17 2062 503 2.18 / 1198.91 2 2
4 13 1001.24 31 12.20 1916 725 2.90 / 1199.64 2 2
5 13 274.68 31 13.72 798 339 3.24 / 1199.98 2 2
6 14 -0.08 180 14.14 359 914 4.15 / 1200.89 2 3
Average= 5.05 (KJ/cycle)

Cycle 236 GMT 20/11/2020 7: 6:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.52 33 14.00 520 240 0.24 / 1190.74 2 2
2 12 1106.16 3 10.59 1985 63 0.30 / 1190.80 2 2
3 12 2002.76 110 7.79 3326 2850 3.15 / 1193.65 2 2
4 7 1992.36 25 10.24 3354 859 4.01 / 1194.51 2 2
5 13 1249.40 31 12.66 2308 906 4.92 / 1195.42 2 2
6 13 342.80 32 13.78 904 399 5.32 / 1195.82 2 2
7 14 -0.12 180 14.24 359 920 6.24 / 1196.74 2 3
Average= 5.05 (KJ/cycle)

Cycle 235 GMT 19/11/2020 3:22: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.28 33 14.03 518 240 0.24 / 1185.85 2 2
2 3 927.40 -1 14.03 518 0 0.00 / 1185.85 2 2
3 12 1130.96 110 4.79 1824 961 1.20 / 1186.81 2 2
4 7 1143.92 24 9.91 2024 481 1.68 / 1187.29 2 2
5 13 1212.72 31 11.65 2212 799 2.48 / 1188.09 2 2
6 13 1149.20 31 12.21 2137 809 3.29 / 1188.90 2 2
7 13 875.08 31 12.90 1728 691 3.98 / 1189.59 2 2
8 14 -0.04 180 14.17 356 908 4.89 / 1190.50 2 4
Average= 5.04 (KJ/cycle)

Cycle 234 GMT 9/11/2020 8:37: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.28 33 13.97 526 242 0.24 / 1181.44 2 2
2 3 1019.24 1 10.03 1839 18 0.26 / 1181.45 2 2
3 12 1119.92 111 5.35 1836 1090 1.35 / 1182.54 2 2
4 7 1131.88 25 10.02 1998 500 1.85 / 1183.04 2 2
5 13 1091.32 31 12.01 2016 751 2.60 / 1183.80 2 2
6 13 973.00 31 12.55 1867 726 3.33 / 1184.52 2 2
7 13 38.12 31 14.07 421 184 3.51 / 1184.71 2 2
8 14 -0.20 180 14.16 355 905 4.42 / 1185.61 2 3
Average= 5.05 (KJ/cycle)

Cycle 233 GMT 30/10/2020 14:11: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.44 31 14.05 526 229 0.23 / 1177.54 2 2
2 12 1128.64 110 7.15 1948 1532 1.76 / 1179.07 2 2
3 7 1134.48 24 10.41 2036 509 2.27 / 1179.58 2 2
4 13 872.00 32 12.69 1707 693 2.96 / 1180.28 2 2
5 14 0.08 181 14.14 358 916 3.88 / 1181.19 2 5
Average= 5.05 (KJ/cycle)

Cycle 232 GMT 20/10/2020 19:51: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.04 33 14.00 521 241 0.24 / 1171.67 2 2
2 12 1095.64 3 10.77 1961 63 0.30 / 1171.74 2 2
3 12 1978.92 110 7.84 3291 2838 3.14 / 1174.57 2 2
4 7 1971.00 24 10.28 3336 823 3.97 / 1175.40 2 2
5 13 962.92 31 13.00 1882 758 4.72 / 1176.16 2 2
6 13 102.92 31 14.07 527 230 4.95 / 1176.39 2 2
7 14 -0.04 181 14.25 360 929 5.88 / 1177.31 2 4
Average= 5.05 (KJ/cycle)

Cycle 231 GMT 19/10/2020 15:22: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.80 32 13.99 539 241 0.24 / 1167.44 2 2
2 12 1132.48 110 5.75 1911 1209 1.45 / 1168.65 2 2
3 7 1142.20 25 10.15 2084 529 1.98 / 1169.18 2 2
4 13 1042.32 31 12.34 1984 759 2.74 / 1169.94 2 2
5 13 633.68 31 13.27 1369 563 3.30 / 1170.50 2 2
6 14 0.04 180 14.17 364 928 4.23 / 1171.43 2 2
Average= 5.05 (KJ/cycle)

Cycle 230 GMT 9/10/2020 21: 0: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.84 32 14.02 515 231 0.23 / 1162.98 2 2
2 12 1104.32 110 5.29 1846 1074 1.31 / 1164.05 2 2
3 7 1115.80 24 10.12 2065 502 1.81 / 1164.55 2 2
4 13 1070.16 32 12.25 2028 795 2.60 / 1165.35 2 2
5 13 961.92 31 12.69 1869 735 3.34 / 1166.08 2 2
6 13 42.04 32 14.10 432 195 3.53 / 1166.28 2 2
7 14 -0.04 180 14.19 362 925 4.46 / 1167.20 2 3
Average= 5.05 (KJ/cycle)

Cycle 229 GMT 30/ 9/2020 2:36: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.28 31 14.08 510 223 0.22 / 1159.25 2 2
2 12 1095.44 80 6.92 1887 1045 1.27 / 1160.30 2 2
3 7 1099.12 24 10.49 2039 513 1.78 / 1160.81 2 2
4 13 916.12 31 12.72 1801 710 2.49 / 1161.52 2 2
5 13 219.12 31 13.84 713 306 2.80 / 1161.82 2 2
6 14 -0.12 181 14.17 359 921 3.72 / 1162.75 2 3
Average= 5.06 (KJ/cycle)

Cycle 228 GMT 20/ 9/2020 8: 8: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.64 33 13.99 536 247 0.25 / 1153.68 2 2
2 12 1100.04 3 10.86 1990 65 0.31 / 1153.74 2 2
3 12 1942.84 80 8.84 3251 2299 2.61 / 1156.04 2 2
4 7 1936.00 25 10.34 3279 848 3.46 / 1156.89 2 2
5 13 1203.40 31 12.73 2247 887 4.35 / 1157.78 2 2
6 13 229.40 32 13.90 733 326 4.67 / 1158.10 2 2
7 14 -0.12 180 14.24 361 925 5.60 / 1159.03 2 5
Average= 5.06 (KJ/cycle)

Cycle 227 GMT 19/ 9/2020 3:44: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.04 32 14.02 523 235 0.23 / 1149.25 2 2
2 3 946.96 -1 14.02 523 0 0.00 / 1149.25 2 2
3 3 1069.96 2 11.14 1952 43 0.28 / 1149.29 2 2
4 12 1120.56 81 5.17 1852 776 1.05 / 1150.07 2 2
5 7 1130.88 24 10.17 2056 502 1.56 / 1150.57 2 2
6 13 1179.40 31 12.25 2197 834 2.39 / 1151.40 2 2
7 13 980.48 31 12.78 1906 755 3.14 / 1152.16 2 2
8 13 297.04 31 13.76 833 355 3.50 / 1152.51 2 2
9 14 -0.24 180 14.18 360 919 4.42 / 1153.43 2 4
Average= 5.06 (KJ/cycle)

Cycle 226 GMT 9/ 9/2020 8:41: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.32 31 13.98 540 234 0.23 / 1144.82 2 2
2 3 1049.44 1 11.21 1940 22 0.26 / 1144.84 2 2
3 3 1020.04 1 10.14 1884 19 0.27 / 1144.86 2 2
4 12 1143.88 80 5.05 1826 738 1.01 / 1145.59 2 2
5 7 1156.56 25 10.05 2074 521 1.53 / 1146.12 2 2
6 13 1216.84 31 12.09 2249 843 2.38 / 1146.96 2 2
7 13 1020.56 31 12.68 1963 772 3.15 / 1147.73 2 2
8 13 305.68 31 13.74 847 361 3.51 / 1148.09 2 2
9 14 0.04 180 14.18 361 921 4.43 / 1149.01 2 4
Average= 5.06 (KJ/cycle)

Cycle 225 GMT 30/ 8/2020 13:35: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 31 14.03 528 230 0.23 / 1141.06 2 2
2 12 1088.88 81 7.02 1919 1091 1.32 / 1142.15 2 2
3 7 1095.40 25 10.62 2030 539 1.86 / 1142.69 2 2
4 13 937.20 31 12.69 1831 720 2.58 / 1143.41 2 2
5 13 132.00 31 13.95 581 251 2.83 / 1143.66 2 2
6 14 -0.04 180 14.15 363 925 3.76 / 1144.58 2 4
Average= 5.06 (KJ/cycle)

Cycle 224 GMT 20/ 8/2020 19: 4: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.16 32 14.00 533 239 0.24 / 1135.49 2 2
2 12 1109.00 3 10.87 2011 66 0.30 / 1135.55 2 2
3 12 1934.88 80 8.69 3238 2251 2.56 / 1137.81 2 2
4 7 1925.16 25 10.31 3273 844 3.40 / 1138.65 2 2
5 13 1212.64 32 12.71 2263 920 4.32 / 1139.57 2 2
6 13 205.04 32 13.93 698 311 4.63 / 1139.88 2 2
7 14 0.00 181 14.22 367 945 5.58 / 1140.83 2 3
Average= 5.07 (KJ/cycle)

Cycle 223 GMT 19/ 8/2020 14:42: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.88 33 13.99 524 242 0.24 / 1131.50 2 2
2 3 890.80 -1 13.99 524 0 0.00 / 1131.50 2 2
3 12 1099.48 80 5.81 1874 871 1.11 / 1132.37 2 2
4 7 1109.12 25 10.32 2041 527 1.64 / 1132.90 2 2
5 13 1023.76 31 12.50 1965 761 2.40 / 1133.66 2 2
6 13 815.48 31 13.01 1649 665 3.07 / 1134.33 2 2
7 14 0.04 180 14.15 363 925 3.99 / 1135.25 2 5
Average= 5.07 (KJ/cycle)

Cycle 222 GMT 9/ 8/2020 20:11: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.48 32 13.99 535 240 0.24 / 1126.99 2 2
2 12 1132.32 80 5.18 1823 755 0.99 / 1127.75 2 2
3 7 1143.24 24 10.28 2046 505 1.50 / 1128.25 2 2
4 13 1187.96 32 12.26 2208 866 2.37 / 1129.12 2 2
5 13 1011.96 32 12.76 1952 797 3.16 / 1129.91 2 2
6 13 133.20 31 13.97 579 251 3.41 / 1130.16 2 2
7 13 4.92 31 14.18 378 166 3.58 / 1130.33 2 2
8 14 0.04 181 14.19 362 930 4.51 / 1131.26 2 6
Average= 5.07 (KJ/cycle)

Cycle 221 GMT 31/ 7/2020 1: 3: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.44 31 14.06 523 228 0.23 / 1123.10 2 2
2 12 1103.72 71 7.07 1922 965 1.19 / 1124.06 2 2
3 7 1109.16 25 10.75 2058 553 1.75 / 1124.62 2 2
4 13 951.76 31 12.74 1857 733 2.48 / 1125.35 2 2
5 13 490.92 31 13.50 1141 478 2.96 / 1125.83 2 2
6 14 -0.12 180 14.17 362 923 3.88 / 1126.75 2 4
Average= 5.08 (KJ/cycle)

Cycle 220 GMT 21/ 7/2020 6:34: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.48 32 14.00 535 240 0.24 / 1117.77 2 2
2 12 1110.60 3 11.18 1997 67 0.31 / 1117.84 2 2
3 12 1917.20 70 9.13 3227 2062 2.37 / 1119.90 2 2
4 7 1909.80 24 10.40 3250 811 3.18 / 1120.71 2 2
5 13 1201.16 31 12.74 2245 887 4.07 / 1121.60 2 2
6 13 243.36 31 13.90 758 327 4.39 / 1121.93 2 2
7 14 0.04 180 14.23 368 943 5.34 / 1122.87 2 4
Average= 5.08 (KJ/cycle)

Cycle 219 GMT 20/ 7/2020 2: 5: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.44 32 13.99 527 236 0.24 / 1113.60 2 2
2 12 1109.64 70 5.34 1855 693 0.93 / 1114.30 2 2
3 7 1118.64 24 10.31 2062 510 1.44 / 1114.81 2 2
4 13 1173.12 31 12.23 2188 830 2.27 / 1115.64 2 2
5 13 992.76 31 12.76 1918 759 3.03 / 1116.39 2 2
6 13 72.68 31 14.07 482 210 3.24 / 1116.60 2 2
7 14 -0.24 180 14.18 364 929 4.17 / 1117.53 2 8
Average= 5.08 (KJ/cycle)

Cycle 218 GMT 10/ 7/2020 6:50: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.00 32 13.99 535 240 0.24 / 1109.50 2 2
2 12 1101.20 70 5.45 1817 693 0.93 / 1110.19 2 2
3 7 1110.12 24 10.43 1987 497 1.43 / 1110.69 2 2
4 13 1112.52 31 12.31 2092 798 2.23 / 1111.49 2 2
5 13 929.20 31 12.83 1819 723 2.95 / 1112.21 2 2
6 13 92.52 31 14.02 517 225 3.18 / 1112.44 2 2
7 14 0.28 180 14.18 364 929 4.11 / 1113.37 2 5
Average= 5.08 (KJ/cycle)

Cycle 217 GMT 30/ 6/2020 11:56: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.72 31 14.03 528 230 0.23 / 1105.73 2 2
2 12 1116.04 70 7.25 1938 984 1.21 / 1106.71 2 2
3 7 1122.04 24 10.86 2072 540 1.75 / 1107.25 2 2
4 13 974.24 31 12.74 1883 744 2.50 / 1108.00 2 2
5 13 291.84 31 13.76 822 351 2.85 / 1108.35 2 2
6 14 -0.40 180 14.18 358 914 3.76 / 1109.26 2 2
Average= 5.09 (KJ/cycle)

Cycle 216 GMT 20/ 6/2020 17:19:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.00 32 14.02 522 234 0.23 / 1100.32 2 2
2 12 1115.32 3 11.00 2035 67 0.30 / 1100.39 2 2
3 12 1938.52 71 9.12 3253 2106 2.41 / 1102.50 2 2
4 7 1930.28 24 10.45 3274 821 3.23 / 1103.32 2 2
5 13 1229.72 31 12.72 2285 901 4.13 / 1104.22 2 2
6 13 274.76 31 13.86 802 345 4.47 / 1104.56 2 2
7 14 -0.04 180 14.23 366 937 5.41 / 1105.50 2 4
Average= 5.09 (KJ/cycle)

Cycle 215 GMT 19/ 6/2020 12:55: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.40 32 14.02 525 236 0.24 / 1096.31 2 2
2 12 1120.88 65 5.64 1861 682 0.92 / 1096.99 2 2
3 7 1130.96 24 10.44 2035 510 1.43 / 1097.50 2 2
4 13 1080.00 31 12.44 2047 789 2.22 / 1098.29 2 2
5 13 879.84 31 12.94 1750 702 2.92 / 1098.99 2 2
6 13 5.52 31 14.19 375 165 3.08 / 1099.16 2 2
7 14 0.08 181 14.19 362 930 4.01 / 1100.09 2 3
Average= 5.09 (KJ/cycle)

Cycle 214 GMT 9/ 6/2020 18:11: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.36 31 14.07 518 226 0.23 / 1092.15 2 2
2 3 1033.60 1 11.54 1904 22 0.25 / 1092.17 2 2
3 3 1018.56 1 10.67 1881 20 0.27 / 1092.19 2 2
4 12 1127.80 65 5.67 1864 687 0.95 / 1092.88 2 2
5 7 1135.88 24 10.59 2047 520 1.48 / 1093.40 2 2
6 13 1086.80 32 12.50 2059 824 2.30 / 1094.22 2 2
7 13 894.96 32 12.96 1765 732 3.03 / 1094.96 2 2
8 13 44.44 32 14.14 435 197 3.23 / 1095.15 2 2
9 14 0.20 181 14.21 358 921 4.15 / 1096.07 2 5
Average= 5.10 (KJ/cycle)

Cycle 213 GMT 30/ 5/2020 23:28: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.32 30 14.08 518 219 0.22 / 1088.33 2 2
2 3 1055.44 1 12.07 1934 23 0.24 / 1088.35 2 2
3 12 1141.80 65 7.62 1964 973 1.21 / 1089.32 2 2
4 7 1149.04 24 10.99 2081 549 1.76 / 1089.87 2 2
5 13 995.36 31 12.79 1920 761 2.53 / 1090.63 2 2
6 13 324.92 31 13.74 874 372 2.90 / 1091.01 2 2
7 14 -0.44 180 14.20 360 920 3.82 / 1091.93 2 3
Average= 5.10 (KJ/cycle)

Cycle 212 GMT 21/ 5/2020 4:48: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.88 32 14.02 529 237 0.24 / 1083.14 2 2
2 12 1106.72 3 11.27 2006 68 0.31 / 1083.20 2 2
3 12 1928.76 65 9.41 3241 1982 2.29 / 1085.19 2 2
4 7 1921.20 25 10.42 3257 848 3.14 / 1086.03 2 2
5 13 1203.12 31 12.74 2242 885 4.02 / 1086.92 2 2
6 13 126.44 32 14.07 572 258 4.28 / 1087.18 2 2
7 14 0.00 180 14.24 363 930 5.21 / 1088.11 2 3
Average= 5.11 (KJ/cycle)

Cycle 211 GMT 20/ 5/2020 0:23: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.12 31 14.06 516 225 0.22 / 1079.08 2 2
2 12 1124.72 65 5.95 1875 725 0.95 / 1079.81 2 2
3 7 1131.64 25 10.60 2023 536 1.49 / 1080.34 2 2
4 13 1043.80 31 12.58 1992 777 2.26 / 1081.12 2 2
5 13 837.92 31 13.02 1682 679 2.94 / 1081.80 2 2
6 13 29.76 31 14.15 412 181 3.12 / 1081.98 2 2
7 14 0.16 180 14.19 360 920 4.04 / 1082.90 2 5
Average= 5.11 (KJ/cycle)

Cycle 210 GMT 10/ 5/2020 5:48: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.36 32 14.07 510 230 0.23 / 1074.98 2 2
2 3 956.80 -1 14.07 510 0 0.00 / 1074.98 2 2
3 3 1031.64 1 11.37 1899 22 0.25 / 1075.00 2 2
4 12 1126.80 65 6.12 1879 747 1.00 / 1075.75 2 2
5 7 1135.44 24 10.78 2052 531 1.53 / 1076.28 2 2
6 13 1055.80 31 12.60 2013 786 2.32 / 1077.07 2 2
7 13 852.40 31 13.02 1707 689 3.00 / 1077.75 2 2
8 13 35.08 31 14.16 419 184 3.19 / 1077.94 2 2
9 14 -0.16 180 14.21 359 918 4.11 / 1078.86 2 6
Average= 5.11 (KJ/cycle)

Cycle 209 GMT 30/ 4/2020 11: 9: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.40 34 14.09 523 251 0.25 / 1071.14 2 2
2 3 876.80 -1 14.09 523 0 0.00 / 1071.14 2 2
3 3 952.20 -1 14.09 523 0 0.00 / 1071.14 2 2
4 12 1159.12 65 7.61 1988 983 1.23 / 1072.12 2 2
5 7 1162.72 25 10.93 2117 578 1.81 / 1072.70 2 2
6 13 998.92 31 12.79 1929 765 2.58 / 1073.46 2 2
7 13 305.52 31 13.76 852 363 2.94 / 1073.83 2 2
8 14 -0.08 180 14.19 361 922 3.86 / 1074.75 2 3
Average= 5.12 (KJ/cycle)

Cycle 208 GMT 20/ 4/2020 16:34: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.44 32 14.09 513 231 0.23 / 1065.83 2 2
2 12 1103.68 3 11.17 2021 68 0.30 / 1065.90 2 2
3 12 1916.80 65 9.48 3229 1990 2.29 / 1067.89 2 2
4 7 1909.24 25 10.46 3247 849 3.14 / 1068.74 2 2
5 13 1195.16 31 12.77 2235 885 4.02 / 1069.62 2 2
6 13 233.60 32 13.91 744 331 4.35 / 1069.95 2 2
7 14 0.04 180 14.24 364 933 5.29 / 1070.89 2 3
Average= 5.12 (KJ/cycle)

Cycle 207 GMT 19/ 4/2020 12:12: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.92 31 14.09 516 225 0.23 / 1061.82 2 2
2 3 1056.52 1 11.70 1942 23 0.25 / 1061.85 2 2
3 12 1143.04 65 6.08 1898 750 1.00 / 1062.60 2 2
4 7 1150.52 24 10.67 2070 530 1.53 / 1063.13 2 2
5 13 1052.44 31 12.64 2007 786 2.31 / 1063.91 2 2
6 13 624.44 32 13.34 1352 577 2.89 / 1064.49 2 2
7 13 34.00 32 14.16 420 190 3.08 / 1064.68 2 2
8 14 -0.04 180 14.21 360 921 4.00 / 1065.60 2 3
Average= 5.12 (KJ/cycle)

Cycle 206 GMT 9/ 4/2020 17:31: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.80 32 14.11 504 228 0.23 / 1057.73 2 2
2 3 942.36 -1 14.11 504 0 0.00 / 1057.73 2 2
3 12 1129.48 65 6.23 1878 760 0.99 / 1058.49 2 2
4 7 1138.32 24 10.86 2055 536 1.52 / 1059.03 2 2
5 13 1051.04 31 12.63 2010 787 2.31 / 1059.82 2 2
6 13 838.68 31 13.05 1682 680 2.99 / 1060.50 2 2
7 13 30.76 31 14.16 415 182 3.17 / 1060.68 2 2
8 14 -0.16 180 14.21 359 918 4.09 / 1061.60 2 3
Average= 5.13 (KJ/cycle)

Cycle 205 GMT 30/ 3/2020 23: 1: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.80 31 14.14 502 220 0.22 / 1053.75 2 2
2 10 1002.64 3 12.76 1922 74 0.29 / 1053.82 2 2
3 12 1082.72 65 7.78 1910 966 1.26 / 1054.79 2 2
4 7 1085.28 25 11.16 2018 563 1.82 / 1055.35 2 2
5 13 940.72 31 12.88 1831 731 2.55 / 1056.08 2 2
6 13 246.84 31 13.84 756 324 2.88 / 1056.40 2 2
7 13 42.68 31 14.17 429 188 3.07 / 1056.59 2 2
8 14 -0.12 180 14.22 357 914 3.98 / 1057.51 2 3
Average= 5.13 (KJ/cycle)

Cycle 204 GMT 21/ 3/2020 4:45: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.56 32 14.11 497 224 0.22 / 1048.59 2 2
2 12 1112.84 3 11.30 2003 68 0.29 / 1048.66 2 2
3 12 1892.08 65 9.62 3193 1997 2.29 / 1050.66 2 2
4 7 1885.80 24 10.49 3205 807 3.10 / 1051.46 2 2
5 13 979.64 32 13.00 1908 794 3.89 / 1052.26 2 2
6 13 256.64 31 13.88 775 333 4.22 / 1052.59 2 2
7 14 0.04 181 14.25 362 934 5.16 / 1053.53 2 3
Average= 5.14 (KJ/cycle)

Cycle 203 GMT 20/ 3/2020 0:19: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.56 32 14.04 526 236 0.24 / 1044.53 2 2
2 12 1110.44 65 6.01 1845 721 0.96 / 1045.25 2 2
3 7 1119.08 25 10.67 2041 544 1.50 / 1045.80 2 2
4 13 1032.64 31 12.60 1979 773 2.27 / 1046.57 2 2
5 13 848.56 31 13.01 1700 686 2.96 / 1047.26 2 2
6 13 35.04 31 14.15 425 186 3.15 / 1047.44 2 2
7 14 -0.28 180 14.20 362 925 4.07 / 1048.37 2 6
Average= 5.14 (KJ/cycle)

Cycle 202 GMT 10/ 3/2020 5:43: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.32 32 14.05 531 239 0.24 / 1040.72 2 2
2 12 1105.24 65 6.83 1898 843 1.08 / 1041.57 2 2
3 7 1113.36 24 10.91 2037 533 1.61 / 1042.10 2 2
4 13 983.12 31 12.75 1905 753 2.37 / 1042.85 2 2
5 13 550.24 31 13.43 1237 515 2.88 / 1043.37 2 2
6 14 0.12 180 14.19 364 930 3.81 / 1044.30 2 4
Average= 5.14 (KJ/cycle)

Cycle 201 GMT 29/ 2/2020 11: 9: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 33 14.11 513 239 0.24 / 1037.00 2 2
2 3 928.56 -1 14.11 513 0 0.00 / 1037.00 2 2
3 12 1124.32 60 8.17 1981 971 1.21 / 1037.97 2 2
4 7 1128.68 24 11.10 2093 558 1.77 / 1038.53 2 2
5 13 965.36 32 12.88 1878 774 2.54 / 1039.31 2 2
6 13 124.80 31 14.01 568 247 2.79 / 1039.55 2 2
7 14 -0.28 181 14.20 363 933 3.72 / 1040.48 2 5
Average= 5.15 (KJ/cycle)

Cycle 200 GMT 19/ 2/2020 16:35: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.24 32 14.09 514 232 0.23 / 1031.93 2 2
2 12 1109.40 4 11.41 2057 94 0.33 / 1032.02 2 2
3 12 1862.84 60 9.89 3165 1878 2.20 / 1033.90 2 2
4 7 1855.60 24 10.51 3166 799 3.00 / 1034.70 2 2
5 13 1149.80 32 12.84 2160 888 3.89 / 1035.59 2 2
6 13 97.64 32 14.14 524 237 4.13 / 1035.82 2 2
7 14 0.04 181 14.26 364 940 5.07 / 1036.76 2 6
Average= 5.16 (KJ/cycle)

Cycle 199 GMT 18/ 2/2020 12:14: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.28 32 14.10 522 236 0.24 / 1027.91 2 2
2 12 1120.88 60 5.99 1844 663 0.90 / 1028.58 2 2
3 7 1130.56 24 10.73 2040 525 1.42 / 1029.10 2 2
4 13 1059.72 31 12.64 2016 790 2.21 / 1029.89 2 2
5 13 858.68 31 13.05 1713 693 2.91 / 1030.59 2 2
6 13 38.04 31 14.17 428 188 3.09 / 1030.77 2 2
7 14 -0.16 180 14.22 361 924 4.02 / 1031.70 2 3
Average= 5.16 (KJ/cycle)

Cycle 198 GMT 8/ 2/2020 17:37: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.80 31 14.08 518 226 0.23 / 1023.92 2 2
2 3 1023.92 1 11.67 1857 22 0.25 / 1023.94 2 2
3 12 1117.20 61 6.65 1863 756 1.00 / 1024.70 2 2
4 7 1124.80 25 10.89 2076 565 1.57 / 1025.26 2 2
5 13 1026.36 31 12.74 1964 776 2.34 / 1026.04 2 2
6 13 586.32 31 13.43 1287 536 2.88 / 1026.57 2 2
7 13 27.36 31 14.19 412 181 3.06 / 1026.75 2 2
8 14 0.04 180 14.22 361 924 3.99 / 1027.68 2 4
Average= 5.16 (KJ/cycle)

Cycle 197 GMT 29/ 1/2020 23: 6: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.08 31 14.14 522 229 0.23 / 1020.04 2 2
2 3 1062.12 2 12.43 1950 48 0.28 / 1020.09 2 2
3 3 1021.88 1 11.49 1891 22 0.30 / 1020.11 2 2
4 12 1130.28 60 8.34 1999 1000 1.30 / 1021.11 2 2
5 7 1134.92 24 11.18 2094 562 1.86 / 1021.67 2 2
6 13 969.76 32 12.91 1878 776 2.64 / 1022.45 2 2
7 13 242.48 31 13.88 745 321 2.96 / 1022.77 2 2
8 14 0.08 181 14.23 359 925 3.88 / 1023.69 2 3
Average= 5.17 (KJ/cycle)

Cycle 196 GMT 20/ 1/2020 4:34: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.84 32 14.09 513 231 0.23 / 1014.91 2 2
2 12 1109.76 4 11.44 2051 94 0.33 / 1015.00 2 2
3 12 1886.56 60 9.90 3189 1894 2.22 / 1016.90 2 2
4 7 1879.84 24 10.56 3198 811 3.03 / 1017.71 2 2
5 13 1176.60 31 12.83 2197 874 3.90 / 1018.58 2 2
6 13 210.48 31 13.98 702 304 4.21 / 1018.88 2 2
7 14 -0.24 180 14.27 361 927 5.14 / 1019.81 2 3
Average= 5.18 (KJ/cycle)

Cycle 195 GMT 19/ 1/2020 0:14: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.96 33 14.05 518 240 0.24 / 1010.75 2 2
2 3 947.76 -1 14.05 518 0 0.00 / 1010.75 2 2
3 3 1032.64 1 11.59 1900 22 0.26 / 1010.77 2 2
4 12 1135.68 61 6.46 1913 754 1.02 / 1011.52 2 2
5 7 1141.80 25 10.82 2087 565 1.58 / 1012.09 2 2
6 13 1054.64 31 12.71 2009 792 2.37 / 1012.88 2 2
7 13 843.88 31 13.11 1686 685 3.06 / 1013.56 2 2
8 13 28.44 31 14.19 415 183 3.24 / 1013.75 2 2
9 14 -0.24 180 14.22 363 929 4.17 / 1014.68 2 3
Average= 5.18 (KJ/cycle)

Cycle 194 GMT 9/ 1/2020 5:40: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.28 32 14.08 529 238 0.24 / 1006.92 2 2
2 3 1020.00 1 11.52 1894 22 0.26 / 1006.95 2 2
3 12 1131.36 60 7.11 1894 808 1.07 / 1007.75 2 2
4 7 1137.72 24 11.14 2032 543 1.61 / 1008.30 2 2
5 13 1004.08 31 12.82 1929 767 2.38 / 1009.06 2 2
6 13 566.64 31 13.45 1255 523 2.90 / 1009.59 2 2
7 14 -0.08 180 14.22 359 919 3.82 / 1010.51 2 3
Average= 5.18 (KJ/cycle)

Cycle 193 GMT 30/12/2019 11:15: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.52 32 14.12 522 236 0.24 / 1004.26 2 2
2 3 945.32 -1 14.12 522 0 0.00 / 1004.26 2 2
3 3 1024.48 1 11.79 1900 22 0.26 / 1004.28 2 2
4 7 1021.12 24 7.26 1773 309 0.57 / 1004.59 2 2
5 13 922.04 31 12.86 1778 709 1.28 / 1005.30 2 2
6 13 478.12 31 13.53 1116 468 1.74 / 1005.76 2 2
7 14 0.04 180 14.19 361 922 2.67 / 1006.69 2 4
Average= 5.19 (KJ/cycle)

Cycle 192 GMT 20/12/2019 17:17: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.04 33 14.10 522 243 0.24 / 999.14 2 2
2 3 940.20 -1 14.10 522 0 0.00 / 999.14 2 2
3 3 1020.32 1 11.29 1879 21 0.26 / 999.16 2 2
4 12 1129.40 5 11.62 2116 123 0.39 / 999.29 2 2
5 12 1838.08 60 10.15 3122 1901 2.29 / 1001.19 2 2
6 7 1831.24 24 10.59 3125 794 3.08 / 1001.98 2 2
7 13 1116.32 32 12.90 2105 869 3.95 / 1002.85 2 2
8 13 89.88 32 14.16 511 232 4.18 / 1003.08 2 2
9 14 0.00 181 14.27 363 938 5.12 / 1004.02 2 5
Average= 5.20 (KJ/cycle)

Cycle 191 GMT 19/12/2019 13: 7:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.08 33 14.07 527 245 0.24 / 995.23 2 2
2 3 948.12 -1 14.07 527 0 0.00 / 995.23 2 2
3 3 1029.84 1 11.63 1887 22 0.27 / 995.25 2 2
4 12 1140.36 60 6.86 1935 796 1.06 / 996.05 2 2
5 7 1148.32 24 10.85 2112 550 1.61 / 996.60 2 2
6 13 1026.32 32 12.75 1973 805 2.42 / 997.41 2 2
7 13 588.16 32 13.41 1298 557 2.98 / 997.96 2 2
8 14 0.04 181 14.22 364 937 3.91 / 998.90 2 3
Average= 5.20 (KJ/cycle)

Cycle 190 GMT 9/12/2019 18:30:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.64 31 14.05 534 233 0.23 / 991.26 2 2
2 10 1026.00 2 12.40 1960 49 0.28 / 991.31 2 2
3 12 1124.84 60 7.55 1957 887 1.17 / 992.20 2 2
4 7 1131.32 25 11.00 2097 577 1.74 / 992.77 2 2
5 13 989.84 31 12.78 1921 761 2.51 / 993.53 2 2
6 13 530.00 32 13.49 1206 521 3.03 / 994.05 2 2
7 14 -0.04 180 14.21 365 934 3.96 / 994.99 2 3
Average= 5.21 (KJ/cycle)

Cycle 189 GMT 30/11/2019 0:21: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.16 27 14.13 518 198 0.20 / 988.40 2 2
2 10 1043.76 3 12.85 2009 77 0.28 / 988.48 2 2
3 3 1083.44 2 12.38 2080 52 0.33 / 988.53 2 2
4 3 1025.00 1 11.97 1903 23 0.35 / 988.55 2 2
5 7 1021.44 24 7.72 1786 331 0.68 / 988.88 2 2
6 13 904.24 32 12.85 1776 730 1.41 / 989.61 2 2
7 13 456.24 32 13.55 1091 473 1.88 / 990.09 2 2
8 14 0.08 180 14.18 369 942 2.83 / 991.03 2 4
Average= 5.22 (KJ/cycle)

Cycle 188 GMT 20/11/2019 6:34: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.84 30 14.05 530 223 0.22 / 983.37 2 2
2 3 1079.80 2 11.93 2030 48 0.27 / 983.42 2 2
3 3 1031.56 1 11.63 1902 22 0.29 / 983.44 2 2
4 12 1127.40 5 11.59 2133 124 0.42 / 983.57 2 2
5 12 1858.64 60 10.03 3157 1900 2.32 / 985.47 2 2
6 7 1852.44 24 10.52 3172 801 3.12 / 986.27 2 2
7 13 937.72 31 13.04 1852 749 3.87 / 987.02 2 2
8 13 101.00 31 14.11 538 235 4.10 / 987.25 2 2
9 14 -0.08 180 14.24 371 951 5.05 / 988.20 2 4
Average= 5.23 (KJ/cycle)

Cycle 187 GMT 19/11/2019 2:17: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.28 33 14.11 526 245 0.24 / 980.83 2 2
2 3 920.92 -1 14.11 526 0 0.00 / 980.83 2 2
3 7 1007.16 24 8.13 1797 351 0.60 / 981.19 2 2
4 13 883.96 32 12.75 1751 714 1.31 / 981.90 2 2
5 13 228.88 31 13.82 728 312 1.62 / 982.21 2 2
6 14 -0.04 181 14.16 366 938 2.56 / 983.15 2 4
Average= 5.23 (KJ/cycle)

Cycle 186 GMT 9/11/2019 8:16: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.84 26 14.13 524 193 0.19 / 976.89 2 2
2 10 1026.52 4 12.94 1975 102 0.29 / 976.99 2 2
3 3 1091.88 2 12.35 2084 51 0.35 / 977.04 2 2
4 3 1026.08 1 11.68 1916 22 0.37 / 977.06 2 2
5 12 1134.80 60 11.97 2123 1525 1.89 / 978.59 2 2
6 7 1135.20 24 11.71 2110 593 2.49 / 979.18 2 2
7 13 431.80 32 13.68 1054 461 2.95 / 979.64 2 2
8 14 -0.20 181 14.24 367 946 3.89 / 980.59 2 3
Average= 5.24 (KJ/cycle)

Cycle 185 GMT 8/11/2019 10:52:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.56 30 14.13 527 223 0.22 / 971.22 2 2
2 12 1125.20 5 6.08 1928 59 0.28 / 971.28 2 2
3 12 1934.16 60 5.01 2784 837 1.12 / 972.12 2 2
4 7 1934.00 24 9.37 3228 726 1.84 / 972.85 2 2
5 13 1799.48 32 11.87 3116 1184 3.03 / 974.03 2 2
6 13 1589.28 31 12.39 2796 1074 4.10 / 975.10 2 2
7 13 686.60 32 13.40 1466 629 4.73 / 975.73 2 2
8 14 -0.08 181 14.27 373 963 5.69 / 976.70 2 6
Average= 5.25 (KJ/cycle)

Cycle 184 GMT 29/10/2019 8:57: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.24 32 14.12 533 241 0.24 / 965.17 2 2
2 3 945.16 -1 14.12 533 0 0.00 / 965.17 2 2
3 12 1122.92 5 6.19 1955 61 0.30 / 965.23 2 2
4 12 1938.32 60 5.04 2933 887 1.19 / 966.12 2 2
5 7 1938.28 24 9.76 3204 751 1.94 / 966.87 2 2
6 13 1791.00 32 12.01 3086 1186 3.12 / 968.05 2 2
7 13 1574.28 32 12.44 2782 1107 4.23 / 969.16 2 2
8 13 850.24 31 13.22 1721 705 4.94 / 969.86 2 2
9 13 9.60 31 14.28 391 173 5.11 / 970.04 2 2
10 14 -0.12 181 14.28 373 964 6.07 / 971.00 2 6
Average= 5.25 (KJ/cycle)

Cycle 183 GMT 19/10/2019 7:15:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.04 32 14.13 541 245 0.24 / 959.09 2 2
2 12 1112.56 5 4.97 2289 57 0.30 / 959.14 2 2
3 12 1944.32 60 5.04 2936 888 1.19 / 960.03 2 2
4 7 1943.96 25 9.78 3223 788 1.98 / 960.82 2 2
5 13 1799.96 31 12.02 3075 1146 3.12 / 961.96 2 2
6 13 1588.76 31 12.40 2823 1085 4.21 / 963.05 2 2
7 13 875.68 32 13.20 1757 742 4.95 / 963.79 2 2
8 13 1.00 32 14.31 378 173 5.12 / 963.96 2 2
9 14 -0.16 181 14.25 373 962 6.09 / 964.93 2 3
Average= 5.24 (KJ/cycle)

Cycle 182 GMT 9/10/2019 5:27: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.52 32 14.12 540 244 0.24 / 953.27 2 2
2 12 1111.80 5 6.20 1922 60 0.30 / 953.33 2 2
3 12 1926.60 60 5.03 2908 878 1.18 / 954.21 2 2
4 7 1927.40 24 9.83 3193 753 1.93 / 954.96 2 2
5 13 1806.32 32 11.93 3125 1193 3.13 / 956.15 2 2
6 13 1594.68 32 12.37 2822 1117 4.24 / 957.27 2 2
7 13 655.36 32 13.44 1412 607 4.85 / 957.88 2 2
8 14 -0.04 181 14.26 374 965 5.82 / 958.84 2 4
Average= 5.24 (KJ/cycle)

Cycle 181 GMT 29/ 9/2019 3:36: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.16 32 14.15 537 243 0.24 / 947.62 2 2
2 12 1096.68 5 6.56 1972 65 0.31 / 947.68 2 2
3 12 1938.92 60 5.04 2923 884 1.19 / 948.56 2 2
4 7 1938.76 24 9.72 3217 750 1.94 / 949.31 2 2
5 13 1795.40 32 11.99 3100 1189 3.13 / 950.50 2 2
6 13 1368.76 31 12.66 2484 975 4.11 / 951.48 2 2
7 13 662.08 31 13.43 1422 592 4.70 / 952.07 2 2
8 14 0.08 180 14.27 371 953 5.65 / 953.02 2 4
Average= 5.24 (KJ/cycle)

Cycle 180 GMT 19/ 9/2019 1:42: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.32 31 14.14 547 240 0.24 / 941.61 2 2
2 3 1042.64 1 12.40 1931 24 0.26 / 941.64 2 2
3 12 1128.04 5 6.70 1937 65 0.33 / 941.70 2 2
4 12 1932.12 60 5.07 3048 927 1.26 / 942.63 2 2
5 7 1931.16 25 9.96 3217 801 2.06 / 943.43 2 2
6 13 1786.64 31 12.07 3107 1163 3.22 / 944.59 2 2
7 13 1585.88 31 12.46 2798 1081 4.30 / 945.67 2 2
8 13 860.88 32 13.23 1739 736 5.04 / 946.41 2 2
9 14 -0.28 181 14.28 373 964 6.00 / 947.37 2 3
Average= 5.23 (KJ/cycle)

Cycle 179 GMT 8/ 9/2019 23:59: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.00 32 14.14 540 244 0.24 / 935.70 2 2
2 3 955.36 -1 14.14 540 0 0.00 / 935.70 2 2
3 3 1025.60 1 11.96 1901 23 0.27 / 935.73 2 2
4 12 1132.04 5 6.33 1958 62 0.33 / 935.79 2 2
5 12 1920.36 60 5.07 3063 932 1.26 / 936.72 2 2
6 7 1920.00 24 10.06 3201 773 2.03 / 937.49 2 2
7 13 1780.12 31 12.13 3068 1154 3.19 / 938.65 2 2
8 13 1570.52 31 12.48 2771 1072 4.26 / 939.72 2 2
9 13 838.96 31 13.26 1693 696 4.96 / 940.41 2 2
10 14 0.00 180 14.28 373 959 5.91 / 941.37 2 6
Average= 5.23 (KJ/cycle)

Cycle 178 GMT 29/ 8/2019 22:22: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.40 32 14.17 530 240 0.24 / 929.76 2 2
2 12 1116.48 5 6.73 1939 65 0.31 / 929.83 2 2
3 12 1927.80 61 5.05 3015 929 1.23 / 930.76 2 2
4 7 1927.24 25 9.93 3238 804 2.04 / 931.56 2 2
5 13 1792.40 31 12.05 3101 1158 3.20 / 932.72 2 2
6 13 1572.80 31 12.45 2790 1077 4.27 / 933.80 2 2
7 13 848.48 31 13.26 1710 703 4.98 / 934.50 2 2
8 14 -0.16 180 14.28 373 959 5.94 / 935.46 2 5
Average= 5.23 (KJ/cycle)

Cycle 177 GMT 19/ 8/2019 20:41: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.60 32 14.15 549 249 0.25 / 923.82 2 2
2 12 1115.04 5 6.68 1927 64 0.31 / 923.89 2 2
3 12 1924.12 60 5.06 3048 925 1.24 / 924.81 2 2
4 7 1923.96 24 10.12 3210 780 2.02 / 925.59 2 2
5 13 1779.04 32 12.13 3059 1187 3.21 / 926.78 2 2
6 13 1560.36 31 12.50 2755 1068 4.27 / 927.85 2 2
7 13 832.32 32 13.27 1688 717 4.99 / 928.56 2 2
8 14 0.04 181 14.29 371 960 5.95 / 929.52 2 9
Average= 5.22 (KJ/cycle)

Cycle 176 GMT 9/ 8/2019 19: 6: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 32 14.18 528 240 0.24 / 917.85 2 2
2 12 1081.44 5 6.84 1887 65 0.30 / 917.92 2 2
3 12 1921.60 60 5.06 3042 924 1.23 / 918.84 2 2
4 7 1921.44 25 10.07 3232 814 2.04 / 919.66 2 2
5 13 1794.24 31 12.05 3113 1163 3.20 / 920.82 2 2
6 13 1577.84 31 12.46 2776 1072 4.28 / 921.89 2 2
7 13 847.84 32 13.26 1710 726 5.00 / 922.62 2 2
8 14 -0.12 181 14.29 370 957 5.96 / 923.57 2 4
Average= 5.22 (KJ/cycle)

Cycle 175 GMT 30/ 7/2019 17:23: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.48 32 14.19 528 240 0.24 / 911.80 2 2
2 12 1099.28 5 4.99 2392 60 0.30 / 911.86 2 2
3 12 1946.92 60 5.20 3109 970 1.27 / 912.83 2 2
4 7 1945.64 24 10.13 3233 786 2.06 / 913.61 2 2
5 13 1780.68 32 12.10 3063 1186 3.24 / 914.80 2 2
6 13 1561.88 32 12.46 2762 1101 4.34 / 915.90 2 2
7 13 591.76 31 13.55 1305 548 4.89 / 916.45 2 2
8 13 69.88 31 14.21 485 214 5.10 / 916.66 2 2
9 14 -0.04 181 14.29 369 954 6.06 / 917.61 2 9
Average= 5.21 (KJ/cycle)

Cycle 174 GMT 20/ 7/2019 15:36: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.56 31 14.17 529 232 0.23 / 905.95 2 2
2 3 1031.12 1 12.70 1909 24 0.26 / 905.97 2 2
3 12 1113.00 5 6.91 1925 67 0.32 / 906.04 2 2
4 12 1929.64 61 5.33 3116 1013 1.34 / 907.05 2 2
5 7 1928.76 24 10.32 3230 800 2.14 / 907.85 2 2
6 13 1758.64 31 12.13 3062 1151 3.29 / 909.00 2 2
7 13 1539.04 31 12.50 2717 1053 4.34 / 910.06 2 2
8 13 591.16 31 13.56 1302 547 4.89 / 910.60 2 2
9 14 0.04 180 14.28 370 951 5.84 / 911.56 2 5
Average= 5.21 (KJ/cycle)

Cycle 173 GMT 10/ 7/2019 13:53: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.12 32 14.17 535 243 0.24 / 900.28 2 2
2 3 950.36 -1 14.17 535 0 0.00 / 900.28 2 2
3 3 1030.08 1 12.51 1932 24 0.27 / 900.30 2 2
4 12 1118.96 5 7.52 1939 73 0.34 / 900.37 2 2
5 12 1920.88 60 6.34 3135 1193 1.53 / 901.56 2 2
6 7 1919.64 25 10.29 3218 828 2.36 / 902.39 2 2
7 13 1736.48 31 12.16 3024 1140 3.50 / 903.53 2 2
8 13 1073.76 31 12.96 2057 826 4.33 / 904.36 2 2
9 13 347.72 32 13.83 921 408 4.73 / 904.77 2 2
10 14 -0.32 180 14.27 370 950 5.68 / 905.72 2 13
Average= 5.21 (KJ/cycle)

Cycle 172 GMT 30/ 6/2019 12: 5: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.60 30 14.18 532 226 0.23 / 894.59 2 2
2 3 1055.52 1 12.76 1988 25 0.25 / 894.62 2 2
3 3 1024.04 1 12.49 1915 24 0.28 / 894.64 2 2
4 12 1128.84 5 4.99 2425 61 0.34 / 894.70 2 2
5 12 1932.68 60 6.94 3165 1318 1.65 / 896.02 2 2
6 7 1930.84 24 10.30 3275 810 2.46 / 896.83 2 2
7 13 1739.12 32 12.13 3029 1176 3.64 / 898.00 2 2
8 13 1070.84 32 12.95 2051 850 4.49 / 898.85 2 2
9 13 83.20 31 14.19 506 223 4.71 / 899.08 2 2
10 14 -0.20 181 14.27 370 956 5.67 / 900.03 2 6
Average= 5.20 (KJ/cycle)

Cycle 171 GMT 20/ 6/2019 10:12: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.48 32 14.17 532 241 0.24 / 889.25 2 2
2 3 938.16 -1 14.17 532 0 0.00 / 889.25 2 2
3 3 1020.08 1 12.37 1902 24 0.26 / 889.27 2 2
4 12 1130.24 5 6.94 1967 68 0.33 / 889.34 2 2
5 7 1911.32 63 7.03 3059 1355 1.69 / 890.69 2 2
6 13 1780.00 31 12.04 3092 1154 2.84 / 891.85 2 2
7 13 1348.48 31 12.67 2461 967 3.81 / 892.81 2 2
8 13 643.04 32 13.45 1395 600 4.41 / 893.41 2 2
9 14 0.00 180 14.26 371 952 5.36 / 894.37 2 8
Average= 5.20 (KJ/cycle)

Cycle 170 GMT 10/ 6/2019 8:26: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 32 14.19 525 238 0.24 / 883.68 2 2
2 12 1094.04 5 7.69 1901 73 0.31 / 883.75 2 2
3 7 1915.92 63 6.98 3064 1347 1.66 / 885.10 2 2
4 13 1783.84 31 12.03 3079 1148 2.81 / 886.25 2 2
5 13 1564.56 31 12.41 2771 1066 3.87 / 887.31 2 2
6 13 594.08 31 13.50 1315 550 4.42 / 887.86 2 2
7 13 27.52 31 14.27 419 185 4.61 / 888.05 2 2
8 14 -0.04 180 14.26 372 955 5.56 / 889.00 2 5
Average= 5.20 (KJ/cycle)

Cycle 169 GMT 31/ 5/2019 6:42: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.40 29 14.22 518 214 0.21 / 878.08 2 2
2 10 1011.76 3 13.01 1958 76 0.29 / 878.16 2 2
3 12 1120.80 5 4.99 2388 60 0.35 / 878.21 2 2
4 7 1929.56 63 7.48 3114 1467 1.82 / 879.68 2 2
5 13 1784.80 31 12.03 3097 1155 2.97 / 880.84 2 2
6 13 1579.40 31 12.40 2797 1075 4.05 / 881.91 2 2
7 13 594.64 32 13.50 1318 569 4.62 / 882.48 2 2
8 14 -0.12 181 14.27 371 958 5.57 / 883.44 2 8
Average= 5.20 (KJ/cycle)

Cycle 168 GMT 21/ 5/2019 5: 6: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.72 31 14.23 519 229 0.23 / 872.71 2 2
2 3 952.16 -1 14.23 519 0 0.00 / 872.71 2 2
3 3 1021.00 1 12.55 1913 24 0.25 / 872.74 2 2
4 12 1124.68 5 5.00 2430 61 0.31 / 872.80 2 2
5 7 1931.12 64 7.91 3162 1601 1.91 / 874.40 2 2
6 13 1751.56 32 12.18 3034 1183 3.10 / 875.58 2 2
7 13 1295.88 31 12.75 2378 940 4.04 / 876.52 2 2
8 13 342.24 31 13.83 917 393 4.43 / 876.91 2 2
9 14 -0.16 180 14.27 371 953 5.38 / 877.87 2 4
Average= 5.19 (KJ/cycle)

Cycle 167 GMT 11/ 5/2019 3:25: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.04 31 14.25 527 233 0.23 / 866.65 2 2
2 7 2005.40 63 7.16 3145 1419 1.65 / 868.06 2 2
3 13 1900.92 32 12.01 3263 1254 2.91 / 869.32 2 2
4 13 1707.72 31 12.32 2981 1139 4.04 / 870.46 2 2
5 13 1010.44 32 13.05 1963 820 4.86 / 871.28 2 2
6 13 115.44 31 14.16 561 246 5.11 / 871.52 2 2
7 14 -0.08 181 14.28 371 959 6.07 / 872.48 2 4
Average= 5.19 (KJ/cycle)

Cycle 166 GMT 1/ 5/2019 3: 5: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.16 31 14.26 512 226 0.23 / 860.65 2 2
2 7 2003.00 64 7.16 3131 1435 1.66 / 862.08 2 2
3 13 1912.92 31 12.02 3260 1215 2.88 / 863.30 2 2
4 13 1697.92 32 12.34 2968 1172 4.05 / 864.47 2 2
5 13 1006.08 31 13.07 1954 792 4.84 / 865.26 2 2
6 13 59.68 31 14.24 474 209 5.05 / 865.47 2 2
7 14 -0.20 180 14.30 367 945 5.99 / 866.41 2 6
Average= 5.19 (KJ/cycle)

Cycle 165 GMT 21/ 4/2019 2:38: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.28 32 14.25 513 234 0.23 / 854.74 2 2
2 3 954.84 -1 14.25 513 0 0.00 / 854.74 2 2
3 3 1042.32 1 12.71 1935 25 0.26 / 854.76 2 2
4 7 2002.88 63 7.18 3072 1390 1.65 / 856.15 2 2
5 13 1905.00 31 12.04 3228 1205 2.85 / 857.36 2 2
6 13 1691.20 32 12.36 2938 1162 4.01 / 858.52 2 2
7 13 987.00 31 13.10 1921 780 4.80 / 859.30 2 2
8 13 28.56 31 14.31 415 184 4.98 / 859.48 2 2
9 14 -0.04 180 14.30 364 937 5.92 / 860.42 2 3
Average= 5.18 (KJ/cycle)

Cycle 164 GMT 11/ 4/2019 2:26: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.76 31 14.26 518 229 0.23 / 848.71 2 2
2 7 2004.08 64 7.41 3097 1469 1.70 / 850.17 2 2
3 13 1903.72 32 12.07 3237 1250 2.95 / 851.42 2 2
4 13 1698.20 32 12.34 2971 1173 4.12 / 852.60 2 2
5 13 978.00 31 13.10 1910 776 4.90 / 853.37 2 2
6 13 44.12 31 14.28 442 196 5.09 / 853.57 2 2
7 14 -0.16 180 14.31 363 935 6.03 / 854.50 2 4
Average= 5.18 (KJ/cycle)

Cycle 163 GMT 1/ 4/2019 2:19: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.92 31 14.26 525 232 0.23 / 842.84 2 2
2 7 2004.00 64 7.56 3087 1494 1.73 / 844.33 2 2
3 13 1885.32 31 12.09 3212 1204 2.93 / 845.54 2 2
4 13 1674.16 32 12.38 2920 1157 4.09 / 846.69 2 2
5 13 759.56 31 13.37 1558 646 4.73 / 847.34 2 2
6 13 51.88 31 14.27 456 202 4.93 / 847.54 2 2
7 14 0.04 180 14.30 363 934 5.87 / 848.48 2 5
Average= 5.17 (KJ/cycle)

Cycle 162 GMT 22/ 3/2019 2: 5: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.44 30 14.24 515 220 0.22 / 836.79 2 2
2 3 1034.96 1 12.76 1935 25 0.24 / 836.81 2 2
3 7 2010.12 64 7.50 3075 1476 1.72 / 838.29 2 2
4 13 1888.44 32 12.09 3203 1239 2.96 / 839.53 2 2
5 13 1692.12 32 12.35 2954 1167 4.13 / 840.69 2 2
6 13 985.80 31 13.09 1916 777 4.90 / 841.47 2 2
7 13 44.92 31 14.30 440 195 5.10 / 841.67 2 2
8 14 -0.08 181 14.30 364 942 6.04 / 842.61 2 3
Average= 5.17 (KJ/cycle)

Cycle 161 GMT 12/ 3/2019 2: 5: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.36 32 14.23 515 235 0.23 / 830.95 2 2
2 3 950.00 -1 14.23 515 0 0.00 / 830.95 2 2
3 3 1027.92 1 12.64 1917 24 0.26 / 830.97 2 2
4 7 2003.08 64 7.85 3043 1529 1.79 / 832.50 2 2
5 13 1859.36 32 12.08 3202 1238 3.03 / 833.74 2 2
6 13 1449.08 32 12.61 2598 1048 4.07 / 834.79 2 2
7 13 745.52 31 13.36 1553 643 4.72 / 835.43 2 2
8 13 33.04 31 14.30 425 188 4.91 / 835.62 2 2
9 14 -0.16 181 14.28 367 949 5.85 / 836.57 2 5
Average= 5.16 (KJ/cycle)

Cycle 160 GMT 2/ 3/2019 1:50: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.84 32 14.27 509 232 0.23 / 824.92 2 2
2 7 2000.48 64 7.50 3088 1482 1.71 / 826.41 2 2
3 13 1872.04 32 12.10 3199 1239 2.95 / 827.65 2 2
4 13 1663.36 32 12.38 2914 1154 4.11 / 828.80 2 2
5 13 952.60 31 13.13 1875 763 4.87 / 829.56 2 2
6 13 39.04 31 14.30 439 195 5.07 / 829.76 2 2
7 14 -0.16 181 14.30 369 955 6.02 / 830.71 2 5
Average= 5.16 (KJ/cycle)

Cycle 159 GMT 20/ 2/2019 1:36: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.12 32 14.22 532 242 0.24 / 818.96 2 2
2 7 2002.80 63 7.72 3031 1474 1.72 / 820.44 2 2
3 13 1880.68 31 12.08 3230 1210 2.93 / 821.65 2 2
4 13 1673.48 31 12.36 2936 1125 4.05 / 822.77 2 2
5 13 953.32 32 13.13 1868 785 4.84 / 823.56 2 2
6 13 18.20 32 14.33 401 184 5.02 / 823.74 2 2
7 14 0.04 181 14.30 368 952 5.97 / 824.69 2 3
Average= 5.15 (KJ/cycle)

Cycle 158 GMT 10/ 2/2019 1:27: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.28 32 14.24 525 239 0.24 / 813.17 2 2
2 7 2000.88 63 8.01 3069 1549 1.79 / 814.72 2 2
3 13 1863.80 31 12.07 3202 1198 2.99 / 815.92 2 2
4 13 1652.88 31 12.37 2911 1116 4.10 / 817.03 2 2
5 13 913.60 31 13.15 1818 741 4.84 / 817.77 2 2
6 14 -0.32 180 14.29 368 947 5.79 / 818.72 2 5
Average= 5.15 (KJ/cycle)

Cycle 157 GMT 31/ 1/2019 1:15: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.28 32 14.24 526 240 0.24 / 807.40 2 2
2 7 2003.48 63 7.99 3052 1536 1.78 / 808.94 2 2
3 13 1863.48 31 12.08 3209 1202 2.98 / 810.14 2 2
4 13 1435.88 31 12.62 2577 1008 3.99 / 811.15 2 2
5 13 759.28 31 13.35 1574 651 4.64 / 811.80 2 2
6 13 19.40 31 14.31 406 180 4.82 / 811.98 2 2
7 14 -0.08 180 14.26 370 950 5.77 / 812.93 2 7
Average= 5.15 (KJ/cycle)

Cycle 156 GMT 21/ 1/2019 0:49: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.64 31 14.26 537 237 0.24 / 801.56 2 2
2 7 2004.00 63 8.18 3044 1569 1.81 / 803.12 2 2
3 13 1862.96 31 12.14 3203 1205 3.01 / 804.33 2 2
4 13 1449.84 31 12.64 2594 1016 4.03 / 805.35 2 2
5 13 750.00 32 13.36 1565 669 4.70 / 806.02 2 2
6 13 36.48 32 14.29 435 199 4.90 / 806.21 2 2
7 14 -0.16 180 14.28 369 948 5.84 / 807.16 2 3
Average= 5.14 (KJ/cycle)

Cycle 155 GMT 11/ 1/2019 0:32: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.92 31 14.26 532 235 0.24 / 795.49 2 2
2 7 2003.80 63 8.34 3063 1609 1.84 / 797.10 2 2
3 13 1859.16 31 12.15 3178 1197 3.04 / 798.29 2 2
4 13 1656.16 31 12.41 2913 1121 4.16 / 799.41 2 2
5 13 910.84 32 13.19 1804 761 4.92 / 800.17 2 2
6 13 31.68 32 14.32 425 195 5.12 / 800.37 2 2
7 14 -0.12 180 14.29 369 949 6.07 / 801.32 2 10
Average= 5.14 (KJ/cycle)

Cycle 154 GMT 1/ 1/2019 0:47: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 31 14.25 518 229 0.23 / 789.56 2 2
2 7 2005.24 63 8.47 3112 1661 1.89 / 791.22 2 2
3 13 1848.16 31 12.12 3197 1201 3.09 / 792.42 2 2
4 13 1635.76 32 12.41 2885 1146 4.24 / 793.57 2 2
5 13 885.08 31 13.20 1772 725 4.96 / 794.29 2 2
6 14 0.08 180 14.27 373 958 5.92 / 795.25 2 5
Average= 5.13 (KJ/cycle)

Cycle 153 GMT 22/12/2018 0:55: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.36 30 14.27 524 224 0.22 / 784.04 2 2
2 7 2005.84 64 8.58 3079 1691 1.92 / 785.73 2 2
3 13 1837.96 31 12.15 3174 1195 3.11 / 786.92 2 2
4 13 1388.40 31 12.68 2516 989 4.10 / 787.91 2 2
5 13 455.24 31 13.73 1096 466 4.57 / 788.38 2 2
6 14 -0.24 180 14.28 370 951 5.52 / 789.33 2 5
Average= 5.13 (KJ/cycle)

Cycle 152 GMT 12/12/2018 0:51: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.56 30 14.26 520 222 0.22 / 778.30 2 2
2 7 2008.12 64 8.56 3068 1681 1.90 / 779.98 2 2
3 13 1852.88 32 12.15 3196 1243 3.15 / 781.23 2 2
4 13 1435.16 31 12.65 2577 1011 4.16 / 782.24 2 2
5 13 716.84 31 13.42 1506 627 4.78 / 782.86 2 2
6 14 -0.12 180 14.28 370 951 5.73 / 783.81 2 4
Average= 5.12 (KJ/cycle)

Cycle 151 GMT 2/12/2018 0:51: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.32 32 14.24 532 242 0.24 / 772.43 2 2
2 3 915.32 -1 14.24 532 0 0.00 / 772.43 2 2
3 7 2001.52 63 8.17 3123 1607 1.85 / 774.04 2 2
4 13 1880.20 31 12.12 3226 1212 3.06 / 775.25 2 2
5 13 1464.32 31 12.61 2620 1024 4.09 / 776.27 2 2
6 13 791.60 31 13.34 1624 672 4.76 / 776.95 2 2
7 13 13.16 31 14.35 398 177 4.93 / 777.12 2 2
8 14 -0.08 180 14.27 373 958 5.89 / 778.08 2 5
Average= 5.12 (KJ/cycle)

Cycle 150 GMT 22/11/2018 0:32: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.60 30 14.22 554 236 0.24 / 766.76 2 2
2 10 1002.12 2 13.12 1933 51 0.29 / 766.82 2 2
3 7 2009.92 64 8.58 3064 1683 1.97 / 768.50 2 2
4 13 1853.52 32 12.17 3159 1230 3.20 / 769.73 2 2
5 13 1433.32 31 12.65 2575 1010 4.21 / 770.74 2 2
6 13 484.04 31 13.72 1142 486 4.70 / 771.22 2 2
7 14 0.08 180 14.28 375 964 5.66 / 772.19 2 8
Average= 5.11 (KJ/cycle)

Cycle 149 GMT 12/11/2018 0:21: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.08 32 14.23 522 238 0.24 / 760.99 2 2
2 3 932.40 -1 14.23 522 0 0.00 / 760.99 2 2
3 7 2004.72 63 8.74 3116 1716 1.95 / 762.70 2 2
4 13 1823.48 31 12.19 3151 1191 3.14 / 763.89 2 2
5 13 1604.92 31 12.45 2842 1097 4.24 / 764.99 2 2
6 13 622.28 32 13.54 1353 586 4.83 / 765.57 2 2
7 14 0.00 180 14.28 371 954 5.78 / 766.53 2 7
Average= 5.11 (KJ/cycle)

Cycle 148 GMT 2/11/2018 0:30: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.48 32 14.19 540 245 0.25 / 755.43 2 2
2 7 2008.16 63 8.68 3137 1715 1.96 / 757.15 2 2
3 13 1843.56 31 12.14 3158 1188 3.15 / 758.33 2 2
4 13 1400.72 31 12.65 2532 993 4.14 / 759.33 2 2
5 13 438.00 32 13.76 1061 467 4.61 / 759.79 2 2
6 14 -0.04 180 14.27 371 953 5.56 / 760.75 2 6
Average= 5.11 (KJ/cycle)

Cycle 147 GMT 23/10/2018 0:18: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.36 31 14.21 539 237 0.24 / 749.94 2 2
2 3 1033.56 1 12.53 1939 24 0.26 / 749.97 2 2
3 7 2003.44 63 9.37 3246 1916 2.18 / 751.88 2 2
4 13 1801.44 31 12.18 3116 1177 3.35 / 753.06 2 2
5 13 1141.48 32 12.92 2149 888 4.24 / 753.95 2 2
6 13 174.84 32 14.12 649 293 4.54 / 754.24 2 2
7 14 -0.24 181 14.30 365 945 5.48 / 755.19 2 4
Average= 5.10 (KJ/cycle)

Cycle 146 GMT 13/10/2018 0:10: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.40 31 14.24 532 235 0.23 / 744.04 2 2
2 7 2007.44 64 9.25 3368 1994 2.23 / 746.03 2 2
3 13 1858.16 32 12.14 3205 1245 3.47 / 747.28 2 2
4 13 1407.20 31 12.63 2547 997 4.47 / 748.28 2 2
5 13 466.20 31 13.72 1113 473 4.94 / 748.75 2 2
6 14 0.16 180 14.27 372 956 5.90 / 749.70 2 7
Average= 5.10 (KJ/cycle)

Cycle 145 GMT 2/10/2018 23:56: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.48 30 14.22 540 230 0.23 / 738.42 2 2
2 3 1025.84 1 12.54 1894 24 0.25 / 738.44 2 2
3 3 1019.60 1 12.23 1911 23 0.28 / 738.47 2 2
4 7 2003.24 64 9.30 3234 1925 2.20 / 740.39 2 2
5 13 1800.64 32 12.19 3119 1217 3.42 / 741.61 2 2
6 13 1331.04 31 12.70 2427 956 4.37 / 742.56 2 2
7 13 170.04 31 14.10 650 284 4.66 / 742.85 2 2
8 14 -0.04 180 14.26 373 957 5.62 / 743.80 2 9
Average= 5.09 (KJ/cycle)

Cycle 144 GMT 22/ 9/2018 23:49: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.20 31 14.21 537 237 0.24 / 732.67 2 2
2 3 946.80 -1 14.21 537 0 0.00 / 732.67 2 2
3 3 1021.84 1 12.17 1921 23 0.26 / 732.69 2 2
4 7 2003.80 63 9.20 3278 1900 2.16 / 734.59 2 2
5 13 1826.36 32 12.15 3138 1220 3.38 / 735.81 2 2
6 13 1366.08 32 12.68 2468 1001 4.38 / 736.81 2 2
7 13 359.20 32 13.85 945 419 4.80 / 737.23 2 2
8 14 -0.08 181 14.25 372 959 5.76 / 738.19 2 8
Average= 5.09 (KJ/cycle)

Cycle 143 GMT 13/ 9/2018 0: 2: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.84 31 14.21 546 241 0.24 / 727.05 2 2
2 7 2007.76 64 9.13 3222 1883 2.12 / 728.94 2 2
3 13 1804.92 32 12.16 3117 1213 3.34 / 730.15 2 2
4 13 1124.28 32 12.92 2120 876 4.21 / 731.02 2 2
5 13 420.48 31 13.76 1043 445 4.66 / 731.47 2 2
6 14 -0.28 181 14.25 372 959 5.62 / 732.43 2 6
Average= 5.09 (KJ/cycle)

Cycle 142 GMT 3/ 9/2018 0: 6: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.76 30 14.21 548 234 0.23 / 721.53 2 2
2 3 1030.84 1 12.63 1925 24 0.26 / 721.55 2 2
3 3 1019.56 1 12.26 1909 23 0.28 / 721.58 2 2
4 7 2003.76 63 9.38 3263 1928 2.21 / 723.51 2 2
5 13 1813.56 31 12.19 3133 1184 3.39 / 724.69 2 2
6 13 1144.96 31 12.91 2146 859 4.25 / 725.55 2 2
7 13 204.40 31 14.06 707 308 4.56 / 725.86 2 2
8 14 0.00 180 14.27 372 956 5.52 / 726.81 2 6
Average= 5.08 (KJ/cycle)

Cycle 141 GMT 23/ 8/2018 23:51: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.44 32 14.20 536 244 0.24 / 715.86 2 2
2 3 928.04 -1 14.20 536 0 0.00 / 715.86 2 2
3 7 2012.48 63 9.43 3271 1943 2.19 / 717.80 2 2
4 13 1808.72 31 12.16 3130 1180 3.37 / 718.98 2 2
5 13 1343.48 31 12.70 2444 962 4.33 / 719.94 2 2
6 13 340.40 31 13.88 911 392 4.72 / 720.34 2 2
7 14 -0.04 180 14.26 374 960 5.68 / 721.30 2 8
Average= 5.08 (KJ/cycle)

Cycle 140 GMT 13/ 8/2018 23:48: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.88 30 14.22 526 224 0.22 / 710.32 2 2
2 3 1064.72 2 12.70 1978 50 0.27 / 710.37 2 2
3 3 1023.72 1 12.46 1898 24 0.30 / 710.39 2 2
4 7 2003.76 63 9.47 3294 1965 2.26 / 712.36 2 2
5 13 1801.56 31 12.19 3117 1178 3.44 / 713.53 2 2
6 13 1130.40 31 12.93 2124 851 4.29 / 714.39 2 2
7 13 148.64 32 14.17 608 276 4.57 / 714.66 2 2
8 14 0.08 180 14.28 371 954 5.52 / 715.61 2 7
Average= 5.08 (KJ/cycle)

Cycle 139 GMT 3/ 8/2018 23:37: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.04 31 14.22 536 236 0.24 / 704.82 2 2
2 3 947.92 -1 14.22 536 0 0.00 / 704.82 2 2
3 3 1036.28 1 12.42 1930 24 0.26 / 704.84 2 2
4 7 2003.36 64 9.65 3246 2005 2.26 / 706.85 2 2
5 13 1811.12 31 12.16 3136 1182 3.45 / 708.03 2 2
6 13 1124.00 31 12.92 2122 850 4.30 / 708.88 2 2
7 13 151.88 31 14.18 609 268 4.56 / 709.15 2 2
8 14 -0.20 180 14.28 368 946 5.51 / 710.09 2 5
Average= 5.07 (KJ/cycle)

Cycle 138 GMT 24/ 7/2018 23:35: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.04 31 14.22 531 234 0.23 / 699.23 2 2
2 7 2004.84 64 9.63 3282 2023 2.26 / 701.25 2 2
3 13 1806.48 32 12.13 3129 1215 3.47 / 702.47 2 2
4 13 1123.36 32 12.91 2121 876 4.35 / 703.34 2 2
5 13 182.64 31 14.12 660 289 4.64 / 703.63 2 2
6 14 -0.24 181 14.27 368 950 5.59 / 704.58 2 11
Average= 5.07 (KJ/cycle)

Cycle 137 GMT 14/ 7/2018 23:15: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.04 31 14.21 535 236 0.24 / 693.43 2 2
2 7 2006.32 64 9.49 3468 2106 2.34 / 695.54 2 2
3 13 1804.76 32 12.19 3120 1217 3.56 / 696.75 2 2
4 13 1143.56 31 12.92 2145 859 4.42 / 697.61 2 2
5 13 412.92 31 13.81 1019 436 4.85 / 698.05 2 2
6 14 -0.04 180 14.27 368 945 5.80 / 699.00 2 6
Average= 5.07 (KJ/cycle)

Cycle 136 GMT 4/ 7/2018 23:15: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.56 29 14.23 544 224 0.22 / 687.81 2 2
2 3 1048.80 1 12.54 1954 25 0.25 / 687.83 2 2
3 3 1023.64 1 12.38 1910 24 0.27 / 687.86 2 2
4 7 2024.92 64 9.95 3316 2112 2.38 / 689.97 2 2
5 13 1814.16 32 12.15 3131 1217 3.60 / 691.19 2 2
6 13 1099.64 31 12.92 2087 836 4.44 / 692.02 2 2
7 13 86.36 31 14.23 512 226 4.66 / 692.25 2 2
8 14 0.08 180 14.25 369 946 5.61 / 693.20 2 5
Average= 5.06 (KJ/cycle)

Cycle 135 GMT 24/ 6/2018 23: 0: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.28 31 14.22 539 238 0.24 / 682.21 2 2
2 3 934.16 -1 14.22 539 0 0.00 / 682.21 2 2
3 7 2004.20 63 9.93 3315 2074 2.31 / 684.28 2 2
4 13 1796.88 32 12.10 3111 1205 3.52 / 685.48 2 2
5 13 1104.08 32 12.92 2089 864 4.38 / 686.35 2 2
6 13 160.56 32 14.12 629 284 4.66 / 686.63 2 2
7 14 0.04 181 14.24 370 954 5.62 / 687.59 2 9
Average= 5.06 (KJ/cycle)

Cycle 134 GMT 14/ 6/2018 23:14: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.48 31 14.21 539 237 0.24 / 676.80 2 2
2 7 2002.48 63 9.83 3294 2040 2.28 / 678.84 2 2
3 13 1804.56 31 12.09 3126 1172 3.45 / 680.01 2 2
4 13 1109.80 31 12.90 2098 839 4.29 / 680.85 2 2
5 13 2.40 31 14.38 382 170 4.46 / 681.02 2 2
6 14 -0.04 180 14.22 369 944 5.40 / 681.97 2 8
Average= 5.05 (KJ/cycle)

Cycle 133 GMT 4/ 6/2018 23:11: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.44 31 14.24 540 238 0.24 / 671.22 2 2
2 7 2008.52 63 9.89 3320 2069 2.31 / 673.29 2 2
3 13 1805.56 31 12.10 3111 1167 3.47 / 674.46 2 2
4 13 1107.40 32 12.90 2091 863 4.34 / 675.32 2 2
5 13 179.16 32 14.10 656 296 4.63 / 675.62 2 2
6 14 -0.12 181 14.26 367 947 5.58 / 676.57 2 5
Average= 5.05 (KJ/cycle)

Cycle 132 GMT 25/ 5/2018 23: 7: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.40 31 14.21 550 242 0.24 / 665.63 2 2
2 7 2003.48 64 9.87 3300 2085 2.33 / 667.71 2 2
3 13 1807.84 32 12.08 3129 1210 3.54 / 668.92 2 2
4 13 1102.40 31 12.91 2094 838 4.37 / 669.76 2 2
5 13 176.00 31 14.11 652 285 4.66 / 670.04 2 2
6 14 0.04 180 14.26 367 942 5.60 / 670.99 2 6
Average= 5.05 (KJ/cycle)

Cycle 131 GMT 15/ 5/2018 23:12: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.76 29 14.24 538 222 0.22 / 660.24 2 2
2 3 1037.68 1 12.38 1943 24 0.25 / 660.27 2 2
3 3 1025.64 1 12.17 1924 23 0.27 / 660.29 2 2
4 7 2008.24 63 10.09 3293 2093 2.36 / 662.39 2 2
5 13 1595.80 31 12.33 2823 1079 3.44 / 663.46 2 2
6 13 934.64 31 13.09 1845 749 4.19 / 664.21 2 2
7 13 76.56 31 14.26 494 218 4.41 / 664.43 2 2
8 14 -0.12 181 14.25 369 952 5.36 / 665.38 2 9
Average= 5.04 (KJ/cycle)

Cycle 130 GMT 5/ 5/2018 23: 3: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.12 31 14.25 528 233 0.23 / 654.91 2 2
2 3 940.20 -1 14.25 528 0 0.00 / 654.91 2 2
3 7 2003.44 63 10.04 3312 2095 2.33 / 657.00 2 2
4 13 1607.92 31 12.30 2847 1086 3.41 / 658.09 2 2
5 13 947.20 31 13.06 1867 756 4.17 / 658.85 2 2
6 13 94.80 31 14.21 524 231 4.40 / 659.08 2 2
7 14 0.08 180 14.25 369 946 5.35 / 660.02 2 9
Average= 5.04 (KJ/cycle)

Cycle 129 GMT 25/ 4/2018 22:49: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.80 29 14.27 535 221 0.22 / 649.55 2 2
2 3 1057.36 1 12.58 1968 25 0.25 / 649.57 2 2
3 3 1019.68 1 12.16 1889 23 0.27 / 649.60 2 2
4 7 2000.80 64 10.02 3266 2094 2.36 / 651.69 2 2
5 13 1587.64 32 12.35 2792 1103 3.47 / 652.79 2 2
6 13 916.88 32 13.13 1806 759 4.23 / 653.55 2 2
7 13 16.08 31 14.35 399 177 4.40 / 653.73 2 2
8 14 -0.08 181 14.23 367 945 5.35 / 654.68 2 8
Average= 5.04 (KJ/cycle)

Cycle 128 GMT 15/ 4/2018 22:42: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.00 30 14.27 526 225 0.23 / 643.93 2 2
2 3 953.32 -1 14.27 526 0 0.00 / 643.93 2 2
3 3 1036.84 1 12.20 1910 23 0.25 / 643.96 2 2
4 7 2004.24 64 10.03 3283 2107 2.36 / 646.06 2 2
5 13 1795.76 32 12.13 3089 1199 3.55 / 647.26 2 2
6 13 1097.44 32 12.94 2075 859 4.41 / 648.12 2 2
7 13 161.60 31 14.15 625 274 4.69 / 648.39 2 2
8 14 -0.08 181 14.27 361 932 5.62 / 649.33 2 8
Average= 5.03 (KJ/cycle)

Cycle 127 GMT 5/ 4/2018 22:44: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.16 31 14.25 532 235 0.24 / 638.12 2 2
2 3 954.28 -1 14.25 532 0 0.00 / 638.12 2 2
3 3 1050.84 1 12.30 1958 24 0.26 / 638.14 2 2
4 7 2005.16 63 10.13 3274 2089 2.35 / 640.23 2 2
5 13 1807.04 31 12.11 3108 1167 3.52 / 641.40 2 2
6 13 1336.48 31 12.68 2431 956 4.47 / 642.35 2 2
7 13 139.40 31 14.18 590 259 4.73 / 642.61 2 2
8 13 4.92 31 14.39 374 167 4.90 / 642.78 2 3
9 14 0.00 180 14.25 361 926 5.82 / 643.71 2 6
Average= 5.03 (KJ/cycle)

Cycle 126 GMT 26/ 3/2018 22:56: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.76 30 14.27 533 228 0.23 / 632.82 2 2
2 3 1025.92 1 11.96 1916 23 0.25 / 632.85 2 2
3 3 1019.92 1 11.20 1908 21 0.27 / 632.87 2 2
4 7 2005.72 63 10.12 3283 2093 2.37 / 634.96 2 2
5 13 1589.32 31 12.36 2798 1072 3.44 / 636.03 2 2
6 13 906.48 31 13.14 1797 732 4.17 / 636.76 2 2
7 13 30.68 32 14.34 415 190 4.36 / 636.96 2 2
8 14 -0.16 180 14.25 362 929 5.29 / 637.88 2 8
Average= 5.02 (KJ/cycle)

Cycle 125 GMT 16/ 3/2018 22:51: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.08 30 14.26 535 229 0.23 / 627.34 2 2
2 7 2001.44 64 10.01 3301 2115 2.34 / 629.46 2 2
3 13 1784.04 32 12.10 3088 1196 3.54 / 630.66 2 2
4 13 1066.84 31 12.96 2030 816 4.35 / 631.47 2 2
5 13 35.84 31 14.34 427 190 4.54 / 631.66 2 2
6 14 0.00 180 14.26 364 934 5.48 / 632.60 2 8
Average= 5.02 (KJ/cycle)

Cycle 124 GMT 6/ 3/2018 22:48: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.72 30 14.27 523 224 0.22 / 621.72 2 2
2 7 2006.08 63 10.19 3330 2138 2.36 / 623.86 2 2
3 13 1796.20 32 12.14 3094 1202 3.56 / 625.06 2 2
4 13 1078.32 32 12.98 2045 849 4.41 / 625.91 2 2
5 13 130.48 32 14.18 576 261 4.67 / 626.17 2 2
6 14 -0.04 181 14.26 365 942 5.62 / 627.12 2 5
Average= 5.02 (KJ/cycle)

Cycle 123 GMT 24/ 2/2018 22:56: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.56 30 14.26 529 226 0.23 / 616.34 2 2
2 7 2000.60 64 10.25 3341 2192 2.42 / 618.53 2 2
3 13 1578.20 32 12.34 2791 1102 3.52 / 619.63 2 2
4 13 894.12 31 13.11 1786 726 4.25 / 620.36 2 2
5 13 38.72 31 14.29 435 193 4.44 / 620.55 2 2
6 14 0.08 181 14.22 369 950 5.39 / 621.50 2 4
Average= 5.01 (KJ/cycle)

Cycle 122 GMT 14/ 2/2018 22:41: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.72 30 14.26 529 226 0.23 / 611.01 2 2
2 7 2001.72 63 10.54 3301 2192 2.42 / 613.20 2 2
3 13 1571.60 31 12.40 2757 1060 3.48 / 614.26 2 2
4 13 866.64 32 13.16 1739 732 4.21 / 615.00 2 2
5 13 3.36 32 14.34 383 176 4.39 / 615.17 2 4
6 14 0.00 180 14.19 368 940 5.33 / 616.11 2 12
Average= 5.01 (KJ/cycle)

Cycle 121 GMT 4/ 2/2018 22:34: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.04 30 14.24 523 223 0.22 / 605.35 2 2
2 7 2001.40 64 10.46 3351 2243 2.47 / 607.60 2 2
3 13 1781.04 32 12.11 3090 1197 3.66 / 608.79 2 2
4 13 1060.52 31 12.92 2043 818 4.48 / 609.61 2 2
5 13 67.76 31 14.19 496 218 4.70 / 609.83 2 2
6 14 -0.12 180 14.18 374 955 5.66 / 610.79 2 5
Average= 5.01 (KJ/cycle)

Cycle 120 GMT 25/ 1/2018 22:26: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 29 14.25 528 218 0.22 / 599.76 2 2
2 7 2000.96 63 10.53 3344 2218 2.44 / 601.98 2 2
3 13 1785.72 31 12.12 3095 1163 3.60 / 603.14 2 2
4 13 1026.36 31 12.95 1994 800 4.40 / 603.94 2 2
5 13 59.08 32 14.19 487 221 4.62 / 604.16 2 2
6 14 -0.32 180 14.14 381 970 5.59 / 605.13 2 8
Average= 5.00 (KJ/cycle)

Cycle 119 GMT 15/ 1/2018 22:16: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.08 31 14.20 546 240 0.24 / 594.29 2 2
2 3 954.68 -1 14.20 546 0 0.00 / 594.29 2 2
3 3 1027.32 1 11.80 1941 23 0.26 / 594.31 2 2
4 7 2002.00 63 10.57 3357 2235 2.50 / 596.54 2 2
5 13 1576.48 32 12.35 2784 1100 3.60 / 597.65 2 2
6 13 891.32 32 13.09 1792 751 4.35 / 598.40 2 2
7 13 5.92 31 14.29 395 175 4.52 / 598.57 2 2
8 14 0.00 180 14.12 381 968 5.49 / 599.54 2 9
Average= 5.00 (KJ/cycle)

Cycle 118 GMT 5/ 1/2018 22: 2: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.00 31 14.21 542 239 0.24 / 588.58 2 2
2 7 2007.04 63 10.48 3372 2226 2.47 / 590.80 2 2
3 13 1786.64 32 12.11 3094 1199 3.66 / 592.00 2 2
4 13 1077.68 32 12.89 2069 853 4.52 / 592.86 2 2
5 13 59.32 31 14.19 487 214 4.73 / 593.07 2 2
6 14 0.00 181 14.13 382 977 5.71 / 594.05 2 10
Average= 4.99 (KJ/cycle)

Cycle 117 GMT 26/12/2017 21:42: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.88 31 14.18 556 244 0.24 / 583.15 2 2
2 7 2022.20 63 10.61 3340 2233 2.48 / 585.39 2 2
3 13 1594.52 31 12.31 2820 1076 3.55 / 586.46 2 2
4 13 887.92 31 13.07 1788 724 4.28 / 587.19 2 3
5 13 4.20 32 14.28 396 181 4.46 / 587.37 2 5
6 14 -0.24 180 14.10 382 970 5.43 / 588.34 2 14
Average= 4.99 (KJ/cycle)

Cycle 116 GMT 16/12/2017 21: 9: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.72 31 14.19 550 242 0.24 / 577.55 2 2
2 7 2013.64 64 10.57 3370 2280 2.52 / 579.83 2 2
3 13 1797.48 32 12.09 3114 1205 3.73 / 581.03 2 2
4 13 849.24 31 13.12 1730 704 4.43 / 581.74 2 2
5 13 30.72 31 14.23 445 196 4.63 / 581.93 2 2
6 14 -0.08 180 14.11 385 978 5.60 / 582.91 2 11
Average= 4.98 (KJ/cycle)

Cycle 115 GMT 6/12/2017 20:33: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.04 29 14.24 544 225 0.22 / 572.12 2 2
2 3 1043.24 1 12.52 1965 25 0.25 / 572.15 2 2
3 3 1027.88 1 12.33 1939 24 0.27 / 572.17 2 2
4 7 2002.48 63 10.56 3339 2221 2.49 / 574.39 2 2
5 13 1567.08 31 12.34 2772 1060 3.55 / 575.45 2 2
6 13 855.68 31 13.12 1735 706 4.26 / 576.16 2 3
7 13 6.28 31 14.29 400 177 4.44 / 576.34 2 3
8 14 -0.20 180 14.09 382 969 5.41 / 577.31 2 12
Average= 4.98 (KJ/cycle)

Cycle 114 GMT 26/11/2017 20:22: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.20 29 14.26 523 216 0.22 / 566.64 2 2
2 7 2003.16 63 10.34 3329 2169 2.38 / 568.81 2 2
3 13 1591.12 31 12.28 2801 1066 3.45 / 569.88 2 2
4 13 1119.20 31 12.85 2106 839 4.29 / 570.72 2 2
5 13 84.48 31 14.21 512 226 4.52 / 570.94 2 2
6 14 -0.08 180 14.19 375 958 5.47 / 571.90 2 8
Average= 4.97 (KJ/cycle)

Cycle 113 GMT 16/11/2017 20:31: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.00 31 14.27 536 237 0.24 / 561.07 2 2
2 3 944.56 -1 14.27 536 0 0.00 / 561.07 2 2
3 3 1025.84 1 11.52 1898 22 0.26 / 561.10 2 2
4 7 2005.32 63 10.35 3323 2167 2.43 / 563.26 2 2
5 13 1794.36 31 12.07 3088 1155 3.58 / 564.42 2 2
6 13 1088.08 32 12.91 2063 852 4.43 / 565.27 2 2
7 13 62.64 32 14.29 470 215 4.65 / 565.49 2 2
8 14 0.28 180 14.22 367 939 5.59 / 566.43 2 6
Average= 4.97 (KJ/cycle)

Cycle 112 GMT 6/11/2017 20:37: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.96 33 14.24 539 253 0.25 / 555.59 2 2
2 3 927.44 -1 14.24 539 0 0.00 / 555.59 2 2
3 7 2000.92 64 10.34 3297 2182 2.44 / 557.77 2 2
4 13 1792.92 32 12.08 3081 1191 3.63 / 558.96 2 2
5 13 885.36 32 13.18 1750 738 4.36 / 559.70 2 2
6 13 38.16 31 14.33 434 193 4.56 / 559.89 2 2
7 14 -0.20 181 14.24 366 943 5.50 / 560.84 2 10
Average= 4.96 (KJ/cycle)

Cycle 111 GMT 27/10/2017 20:40: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.12 29 14.31 539 224 0.22 / 550.20 2 2
2 3 1121.04 3 12.83 2071 80 0.30 / 550.27 2 2
3 3 1041.28 1 12.81 1909 24 0.33 / 550.30 2 2
4 7 2001.36 63 10.33 3266 2125 2.45 / 552.42 2 2
5 13 1793.84 31 12.11 3064 1150 3.60 / 553.58 2 2
6 13 1069.00 31 12.95 2040 819 4.42 / 554.39 2 2
7 14 -0.36 180 14.24 368 943 5.37 / 555.34 2 10
Average= 4.96 (KJ/cycle)

Cycle 110 GMT 17/10/2017 20:32: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.00 31 14.27 526 233 0.23 / 544.74 2 2
2 3 923.96 -1 14.27 526 0 0.00 / 544.74 2 2
3 7 2004.04 63 10.43 3288 2161 2.39 / 546.90 2 2
4 13 1786.20 31 12.18 3044 1149 3.54 / 548.05 2 2
5 13 1081.64 31 12.97 2050 824 4.37 / 548.87 2 3
6 13 3.88 31 14.41 376 168 4.53 / 549.04 2 2
7 14 -0.16 180 14.22 364 932 5.47 / 549.97 2 10
Average= 4.95 (KJ/cycle)

Cycle 109 GMT 7/10/2017 20:44: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.28 32 14.28 526 240 0.24 / 539.12 2 2
2 3 946.92 -1 14.28 526 0 0.00 / 539.12 2 2
3 3 1027.68 1 11.89 1923 23 0.26 / 539.14 2 2
4 7 2005.08 63 10.65 3308 2220 2.48 / 541.36 2 2
5 13 1791.40 31 12.14 3089 1163 3.65 / 542.52 2 2
6 13 1063.44 32 12.96 2027 841 4.49 / 543.36 2 2
7 13 41.04 32 14.33 438 201 4.69 / 543.56 2 2
8 14 0.12 181 14.23 365 940 5.63 / 544.50 2 6
Average= 4.95 (KJ/cycle)

Cycle 108 GMT 27/ 9/2017 20:43: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.48 30 14.27 525 225 0.22 / 533.74 2 2
2 3 1066.32 2 12.51 1967 49 0.27 / 533.79 2 2
3 7 2003.84 63 10.40 3292 2157 2.43 / 535.95 2 2
4 13 1576.72 31 12.35 2766 1059 3.49 / 537.01 2 2
5 13 887.32 32 13.12 1772 744 4.23 / 537.75 2 2
6 13 18.80 32 14.34 405 186 4.42 / 537.94 2 2
7 14 -0.28 180 14.20 368 941 5.36 / 538.88 2 9
Average= 4.94 (KJ/cycle)

Cycle 107 GMT 17/ 9/2017 20:11: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.16 29 14.33 524 218 0.22 / 528.66 2 2
2 7 2002.96 63 10.44 3273 2153 2.37 / 530.81 2 2
3 13 1575.56 31 12.39 2752 1057 3.43 / 531.87 2 2
4 13 891.56 31 13.17 1766 721 4.15 / 532.59 2 2
5 14 -0.16 180 14.24 361 925 5.07 / 533.52 2 9
Average= 4.94 (KJ/cycle)

Cycle 106 GMT 7/ 9/2017 20:15: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.16 32 14.28 535 244 0.24 / 523.33 2 2
2 3 953.88 -1 14.28 535 0 0.00 / 523.33 2 2
3 7 2012.24 63 10.42 3307 2171 2.42 / 525.50 2 2
4 13 1585.96 32 12.33 2796 1103 3.52 / 526.61 2 2
5 13 897.16 32 13.16 1772 746 4.26 / 527.35 2 3
6 13 4.44 32 14.41 373 172 4.44 / 527.53 2 2
7 14 -0.04 180 14.22 359 919 5.36 / 528.44 2 7
Average= 4.94 (KJ/cycle)

Cycle 105 GMT 28/ 8/2017 20: 6: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.48 29 14.33 532 221 0.22 / 517.95 2 2
2 3 1086.48 2 12.76 2012 51 0.27 / 518.00 2 2
3 3 1029.96 1 12.61 1900 24 0.30 / 518.02 2 2
4 7 2000.76 64 10.32 3256 2151 2.45 / 520.17 2 2
5 13 1564.76 32 12.40 2770 1099 3.55 / 521.27 2 2
6 13 872.16 32 13.23 1728 732 4.28 / 522.00 2 3
7 13 8.56 32 14.41 375 173 4.45 / 522.17 2 2
8 14 0.08 180 14.22 357 914 5.36 / 523.09 2 8
Average= 4.93 (KJ/cycle)

Cycle 104 GMT 18/ 8/2017 19:57: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.84 31 14.33 535 238 0.24 / 512.53 2 2
2 3 908.44 -1 14.33 535 0 0.00 / 512.53 2 2
3 7 2003.84 57 10.25 3255 1902 2.14 / 514.43 2 2
4 13 1803.04 34 12.09 3093 1271 3.41 / 515.71 2 2
5 13 1077.88 34 12.97 2034 897 4.31 / 516.60 2 2
6 13 32.28 34 14.40 411 201 4.51 / 516.80 2 2
7 14 0.00 180 14.27 358 920 5.43 / 517.72 2 8
Average= 4.93 (KJ/cycle)

Cycle 103 GMT 8/ 8/2017 19:41: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.40 31 14.31 527 234 0.23 / 507.04 2 2
2 7 2004.12 57 10.27 3236 1894 2.13 / 508.93 2 2
3 13 1804.80 33 12.13 3094 1238 3.37 / 510.17 2 2
4 13 1095.12 33 12.96 2065 883 4.25 / 511.05 2 2
5 13 178.48 34 14.17 645 311 4.56 / 511.37 2 2
6 14 0.00 181 14.28 360 930 5.49 / 512.30 2 5
Average= 4.93 (KJ/cycle)

Cycle 102 GMT 29/ 7/2017 19:26: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.00 30 14.31 530 228 0.23 / 501.42 2 2
2 3 1020.96 1 10.89 1904 21 0.25 / 501.44 2 2
3 7 2005.72 57 10.48 3259 1947 2.20 / 503.38 2 2
4 13 1791.76 33 12.17 3089 1241 3.44 / 504.62 2 2
5 13 1067.36 33 13.00 2027 870 4.31 / 505.49 2 2
6 13 57.60 33 14.35 455 215 4.52 / 505.71 2 2
7 13 4.08 33 14.40 372 177 4.70 / 505.89 2 2
8 14 0.20 181 14.23 357 919 5.62 / 506.80 2 7
Average= 4.92 (KJ/cycle)

Cycle 101 GMT 19/ 7/2017 19:10: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 30 14.35 521 224 0.22 / 495.96 2 2
2 7 2006.28 57 10.43 3333 1982 2.21 / 497.94 2 2
3 13 1588.08 31 12.44 2805 1082 3.29 / 499.02 2 2
4 13 1135.60 31 12.94 2127 853 4.14 / 499.88 2 2
5 13 16.32 31 14.41 391 175 4.32 / 500.05 2 2
6 13 5.60 31 14.30 377 167 4.48 / 500.22 2 3
7 14 -0.24 190 14.19 359 968 5.45 / 501.19 2 7
Average= 4.91 (KJ/cycle)

Cycle 100 GMT 9/ 7/2017 18:34: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.80 30 14.37 517 223 0.22 / 490.59 2 2
2 7 2001.24 57 10.60 3278 1981 2.20 / 492.57 2 2
3 13 1783.36 31 12.25 3082 1170 3.37 / 493.74 2 2
4 13 1063.20 32 13.03 2020 842 4.22 / 494.58 2 2
5 13 13.08 32 14.41 388 179 4.40 / 494.76 2 2
6 14 -0.04 191 14.20 361 979 5.37 / 495.74 2 8
Average= 4.91 (KJ/cycle)

Cycle 99 GMT 29/ 6/2017 18:13: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.20 30 14.34 518 223 0.22 / 485.42 2 2
2 3 966.68 -1 14.34 518 0 0.00 / 485.42 2 2
3 3 1039.20 1 12.41 1932 24 0.25 / 485.44 2 2
4 7 2010.20 57 10.95 3299 2059 2.31 / 487.50 2 2
5 13 1582.24 32 12.51 2731 1093 3.40 / 488.60 2 2
6 13 691.72 32 13.47 1453 626 4.03 / 489.22 2 2
7 13 2.36 31 14.42 373 167 4.19 / 489.39 2 2
8 14 -0.12 190 14.21 361 975 5.17 / 490.36 2 6
Average= 4.90 (KJ/cycle)

Cycle 98 GMT 19/ 6/2017 17:28: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.28 30 14.36 529 228 0.23 / 480.05 2 2
2 3 958.76 -1 14.36 529 0 0.00 / 480.05 2 2
3 3 1041.84 1 12.51 1930 24 0.25 / 480.07 2 2
4 7 2003.76 58 10.88 3296 2080 2.33 / 482.15 2 2
5 13 1584.16 31 12.49 2781 1077 3.41 / 483.23 2 2
6 13 719.68 31 13.38 1520 630 4.04 / 483.86 2 2
7 13 30.28 31 14.37 420 187 4.23 / 484.04 2 2
8 13 15.48 31 14.27 397 176 4.40 / 484.22 2 2
9 14 0.00 190 14.16 363 977 5.38 / 485.20 2 13
Average= 4.90 (KJ/cycle)

Cycle 97 GMT 9/ 6/2017 16:37: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.20 31 14.34 533 237 0.24 / 474.80 2 2
2 3 968.24 -1 14.34 533 0 0.00 / 474.80 2 2
3 3 1033.88 1 12.25 1937 24 0.26 / 474.82 2 2
4 7 2006.76 58 10.84 3327 2092 2.35 / 476.91 2 2
5 13 1584.40 31 12.48 2797 1082 3.43 / 478.00 2 2
6 13 720.84 31 13.40 1517 630 4.06 / 478.63 2 2
7 13 56.08 31 14.35 459 204 4.27 / 478.83 2 2
8 14 -0.04 190 14.24 365 988 5.26 / 479.82 2 4
Average= 4.90 (KJ/cycle)

Cycle 96 GMT 30/ 5/2017 16:19: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.12 31 14.37 525 234 0.23 / 469.76 2 2
2 3 956.20 -1 14.37 525 0 0.00 / 469.76 2 2
3 3 1046.64 1 12.56 1950 24 0.26 / 469.79 2 2
4 7 2003.68 57 10.85 3307 2045 2.30 / 471.83 2 2
5 13 1603.80 32 12.50 2793 1117 3.42 / 472.95 2 2
6 13 708.04 31 13.44 1494 622 4.04 / 473.57 2 2
7 14 0.00 190 14.24 366 990 5.03 / 474.56 2 7
Average= 4.89 (KJ/cycle)

Cycle 95 GMT 20/ 5/2017 16: 4: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.96 30 14.34 535 230 0.23 / 464.72 2 2
2 3 1034.24 1 12.38 1935 24 0.25 / 464.74 2 2
3 7 2002.20 57 10.89 3306 2052 2.31 / 466.80 2 2
4 13 1571.76 31 12.52 2780 1079 3.39 / 467.88 2 2
5 13 741.32 32 13.40 1548 664 4.05 / 468.54 2 2
6 14 -0.28 190 14.25 365 988 5.04 / 469.53 2 9
Average= 4.89 (KJ/cycle)

Cycle 94 GMT 10/ 5/2017 15:35: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.96 30 14.39 527 228 0.23 / 459.54 2 2
2 3 971.92 -1 14.39 527 0 0.00 / 459.54 2 2
3 3 1051.96 1 12.67 1957 25 0.25 / 459.56 2 2
4 7 2018.16 57 10.87 3325 2060 2.31 / 461.62 2 2
5 13 1608.04 32 12.54 2809 1127 3.44 / 462.75 2 2
6 13 897.16 32 13.22 1786 756 4.20 / 463.50 2 2
7 14 0.00 190 14.25 364 986 5.18 / 464.49 2 9
Average= 4.89 (KJ/cycle)

Cycle 93 GMT 30/ 4/2017 15: 2: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.40 31 14.41 529 236 0.24 / 454.47 2 2
2 3 934.72 -1 14.41 529 0 0.00 / 454.47 2 2
3 3 1027.44 1 12.05 1943 23 0.26 / 454.49 2 2
4 7 2003.96 57 10.89 3317 2059 2.32 / 456.55 2 2
5 13 1608.12 31 12.52 2833 1100 3.42 / 457.65 2 2
6 13 764.20 32 13.38 1585 679 4.10 / 458.33 2 2
7 14 -0.04 190 14.26 362 981 5.08 / 459.31 2 11
Average= 4.89 (KJ/cycle)

Cycle 92 GMT 20/ 4/2017 14:36: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.84 31 14.38 527 235 0.23 / 448.97 2 2
2 7 2018.72 57 10.81 3370 2076 2.31 / 451.05 2 2
3 13 1829.80 32 12.32 3160 1246 3.56 / 452.29 2 2
4 13 897.76 31 13.22 1798 737 4.29 / 453.03 2 2
5 13 72.08 31 14.34 484 215 4.51 / 453.24 2 2
6 14 -0.20 190 14.26 365 989 5.50 / 454.23 2 7
Average= 4.88 (KJ/cycle)

Cycle 91 GMT 10/ 4/2017 14:11: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.80 29 14.36 526 219 0.22 / 443.85 2 2
2 3 1053.12 1 12.83 1986 25 0.24 / 443.88 2 2
3 3 1021.24 1 12.73 1943 25 0.27 / 443.90 2 2
4 7 2001.00 58 11.10 3287 2116 2.39 / 446.02 2 2
5 13 1592.24 31 12.59 2783 1086 3.47 / 447.11 2 2
6 13 722.20 31 13.45 1522 635 4.11 / 447.74 2 2
7 14 -0.04 190 14.26 367 994 5.10 / 448.73 2 8
Average= 4.88 (KJ/cycle)

Cycle 90 GMT 31/ 3/2017 13:34: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 29 14.43 518 217 0.22 / 438.85 2 2
2 7 2002.64 57 11.01 3343 2098 2.31 / 440.95 2 2
3 13 1570.80 31 12.61 2757 1078 3.39 / 442.03 2 2
4 13 696.16 31 13.46 1477 616 4.01 / 442.65 2 2
5 14 -0.04 190 14.23 365 987 5.00 / 443.63 2 7
Average= 4.88 (KJ/cycle)

Cycle 89 GMT 21/ 3/2017 12:55: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.60 29 14.43 509 213 0.21 / 433.64 2 2
2 7 2004.20 57 11.10 3288 2080 2.29 / 435.72 2 2
3 13 1588.12 32 12.62 2742 1107 3.40 / 436.83 2 2
4 13 700.52 32 13.45 1492 642 4.04 / 437.47 2 2
5 13 1.08 32 14.42 377 174 4.22 / 437.65 2 2
6 14 -0.16 190 14.16 369 993 5.21 / 438.64 2 12
Average= 4.87 (KJ/cycle)

Cycle 88 GMT 11/ 3/2017 11:55: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.16 29 14.39 523 218 0.22 / 428.43 2 2
2 7 2001.28 57 11.05 3326 2095 2.31 / 430.52 2 2
3 13 1564.72 32 12.61 2772 1119 3.43 / 431.64 2 2
4 13 681.68 31 13.47 1465 612 4.04 / 432.25 2 2
5 13 20.28 31 14.36 413 184 4.23 / 432.44 2 2
6 14 -0.08 190 14.19 367 989 5.22 / 433.43 2 12
Average= 4.87 (KJ/cycle)

Cycle 87 GMT 1/ 3/2017 11:25: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.04 29 14.40 519 217 0.22 / 423.22 2 2
2 3 965.44 -1 14.40 519 0 0.00 / 423.22 2 2
3 3 1026.88 1 12.60 1953 25 0.24 / 423.25 2 2
4 7 2004.12 57 11.02 3329 2091 2.33 / 425.34 2 2
5 13 1588.16 31 12.61 2799 1094 3.43 / 426.43 2 2
6 13 682.24 31 13.49 1464 612 4.04 / 427.04 2 2
7 13 2.00 31 14.40 385 172 4.21 / 427.22 2 2
8 14 -0.16 190 14.15 370 995 5.21 / 428.21 2 7
Average= 4.87 (KJ/cycle)

Cycle 86 GMT 19/ 2/2017 10:45: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.68 30 14.46 520 226 0.23 / 418.22 2 2
2 3 959.08 -1 14.46 520 0 0.00 / 418.22 2 2
3 3 1032.00 1 12.66 1937 25 0.25 / 418.25 2 2
4 7 2001.08 57 10.84 3272 2022 2.27 / 420.27 2 2
5 13 1408.52 31 12.80 2516 998 3.27 / 421.27 2 2
6 13 566.08 31 13.64 1292 546 3.82 / 421.81 2 2
7 13 17.68 32 14.36 412 189 4.01 / 422.00 2 2
8 14 0.00 190 14.11 374 1003 5.01 / 423.01 2 6
Average= 4.86 (KJ/cycle)

Cycle 85 GMT 9/ 2/2017 9:41: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.40 31 14.45 520 233 0.23 / 413.09 2 2
2 3 935.24 -1 14.45 520 0 0.00 / 413.09 2 2
3 7 2004.76 57 10.61 3241 1960 2.19 / 415.05 2 2
4 13 1610.36 32 12.64 2822 1141 3.33 / 416.19 2 2
5 13 732.48 31 13.51 1535 643 3.98 / 416.84 2 2
6 13 20.36 31 14.45 402 180 4.16 / 417.02 2 2
7 14 -0.16 190 14.24 363 982 5.14 / 418.00 2 6
Average= 4.86 (KJ/cycle)

Cycle 84 GMT 30/ 1/2017 9:18: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.04 31 14.44 523 234 0.23 / 407.90 2 2
2 3 946.52 -1 14.44 523 0 0.00 / 407.90 2 2
3 3 1035.04 1 12.74 1935 25 0.26 / 407.93 2 2
4 7 2002.60 57 10.58 3281 1979 2.24 / 409.90 2 2
5 13 1618.80 31 12.65 2839 1113 3.35 / 411.02 2 2
6 13 783.12 31 13.49 1605 671 4.02 / 411.69 2 2
7 13 27.56 32 14.44 415 192 4.21 / 411.88 2 2
8 14 -0.16 190 14.25 361 977 5.19 / 412.86 2 5
Average= 4.86 (KJ/cycle)

Cycle 83 GMT 20/ 1/2017 8:53: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.72 29 14.45 539 226 0.23 / 402.89 2 2
2 3 1052.08 1 13.27 1961 26 0.25 / 402.92 2 2
3 7 2003.60 57 10.75 3276 2007 2.26 / 404.92 2 2
4 13 1585.96 32 12.69 2770 1125 3.38 / 406.05 2 2
5 13 707.20 31 13.57 1489 626 4.01 / 406.67 2 2
6 14 -0.04 190 14.28 366 993 5.00 / 407.67 2 8
Average= 4.85 (KJ/cycle)

Cycle 82 GMT 10/ 1/2017 8:27: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.52 29 14.46 520 218 0.22 / 397.93 2 2
2 7 2003.72 57 10.66 3292 2000 2.22 / 399.93 2 2
3 13 1439.36 32 12.83 2580 1059 3.28 / 400.98 2 2
4 13 798.04 31 13.46 1629 680 3.96 / 401.66 2 2
5 14 -0.12 190 14.25 369 999 4.96 / 402.66 2 10
Average= 4.85 (KJ/cycle)

Cycle 81 GMT 31/12/2016 7:51: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.96 31 14.45 527 236 0.24 / 392.80 2 2
2 3 927.68 -1 14.45 527 0 0.00 / 392.80 2 2
3 7 2007.56 58 10.65 3310 2045 2.28 / 394.84 2 2
4 13 1634.80 29 12.71 2852 1051 3.33 / 395.89 2 2
5 13 817.68 29 13.50 1653 647 3.98 / 396.54 2 2
6 13 33.80 29 14.43 430 180 4.16 / 396.72 2 2
7 14 0.00 190 14.24 365 988 5.15 / 397.71 2 8
Average= 4.85 (KJ/cycle)

Cycle 80 GMT 21/12/2016 7: 6: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.00 31 14.44 537 240 0.24 / 387.65 2 2
2 3 962.24 -1 14.44 537 0 0.00 / 387.65 2 2
3 3 1050.52 1 13.11 1983 26 0.27 / 387.67 2 2
4 7 2000.88 58 10.78 3291 2058 2.32 / 389.73 2 2
5 13 1594.96 29 12.73 2816 1040 3.36 / 390.77 2 2
6 13 762.52 29 13.55 1579 620 3.98 / 391.39 2 2
7 13 27.64 29 14.45 420 176 4.16 / 391.57 2 2
8 14 -0.20 190 14.23 367 992 5.15 / 392.56 2 8
Average= 4.85 (KJ/cycle)

Cycle 79 GMT 11/12/2016 6:43: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.04 30 14.45 525 228 0.23 / 382.37 2 2
2 3 971.52 -1 14.45 525 0 0.00 / 382.37 2 2
3 3 1058.96 2 13.25 1959 52 0.28 / 382.42 2 2
4 7 2002.44 58 10.81 3286 2060 2.34 / 384.48 2 2
5 13 1607.36 29 12.74 2826 1044 3.38 / 385.53 2 2
6 13 939.00 29 13.36 1857 719 4.10 / 386.25 2 2
7 13 5.92 29 14.46 387 162 4.27 / 386.41 2 2
8 14 -0.08 190 14.20 370 998 5.26 / 387.41 2 4
Average= 4.84 (KJ/cycle)

Cycle 78 GMT 1/12/2016 6:38: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.96 31 14.42 553 247 0.25 / 377.36 2 2
2 3 956.80 -1 14.42 553 0 0.00 / 377.36 2 2
3 3 1037.64 1 13.12 1933 25 0.27 / 377.39 2 2
4 7 2000.64 57 10.83 3307 2041 2.31 / 379.43 2 2
5 13 1583.04 28 12.81 2802 1005 3.32 / 380.43 2 2
6 13 921.80 29 13.40 1830 711 4.03 / 381.14 2 2
7 14 0.00 190 14.26 369 1000 5.03 / 382.14 2 10
Average= 4.84 (KJ/cycle)

Cycle 77 GMT 21/11/2016 6:17: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.08 30 14.47 526 228 0.23 / 372.10 2 2
2 3 1035.08 1 13.21 1944 26 0.25 / 372.13 2 2
3 7 2005.96 57 10.94 3322 2072 2.33 / 374.20 2 2
4 13 1592.32 29 12.78 2801 1038 3.36 / 375.24 2 2
5 13 931.00 28 13.41 1835 689 4.05 / 375.93 2 2
6 13 39.12 28 14.44 440 178 4.23 / 376.11 2 2
7 14 0.00 190 14.24 373 1009 5.24 / 377.11 2 9
Average= 4.83 (KJ/cycle)

Cycle 76 GMT 11/11/2016 5:54: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.20 29 14.44 546 229 0.23 / 367.02 2 2
2 7 2001.36 50 11.05 3290 1818 2.05 / 368.83 2 2
3 13 1801.04 29 12.59 3122 1140 3.19 / 369.97 2 2
4 13 952.16 28 13.38 1872 701 3.89 / 370.68 2 2
5 13 61.84 28 14.42 478 193 4.08 / 370.87 2 2
6 14 0.04 190 14.24 372 1006 5.09 / 371.87 2 6
Average= 4.83 (KJ/cycle)

Cycle 75 GMT 1/11/2016 5:27: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.12 29 14.43 540 226 0.23 / 361.99 2 2
2 7 2004.16 50 11.01 3291 1812 2.04 / 363.80 2 2
3 13 1804.92 28 12.58 3123 1100 3.14 / 364.90 2 2
4 13 951.72 28 13.39 1866 700 3.84 / 365.60 2 2
5 13 55.52 28 14.44 467 189 4.03 / 365.79 2 2
6 14 -0.44 190 14.27 369 1000 5.03 / 366.79 2 7
Average= 4.83 (KJ/cycle)

Cycle 74 GMT 22/10/2016 4:54: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.24 29 14.46 532 223 0.22 / 356.93 2 2
2 7 2003.00 50 11.03 3346 1845 2.07 / 358.78 2 2
3 13 1803.04 28 12.58 3128 1102 3.17 / 359.88 2 2
4 13 921.48 28 13.41 1831 688 3.86 / 360.57 2 2
5 13 48.40 28 14.43 458 185 4.04 / 360.75 2 2
6 14 0.00 190 14.24 372 1006 5.05 / 361.76 2 7
Average= 4.82 (KJ/cycle)

Cycle 73 GMT 12/10/2016 4:38: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.52 30 14.48 533 232 0.23 / 351.93 2 2
2 3 938.08 -1 14.48 533 0 0.00 / 351.93 2 2
3 7 2003.72 50 11.18 3306 1848 2.08 / 353.78 2 2
4 13 1620.56 28 12.81 2816 1010 3.09 / 354.79 2 2
5 13 962.20 28 13.42 1899 714 3.80 / 355.50 2 2
6 13 59.40 28 14.43 475 192 4.00 / 355.69 2 2
7 14 0.08 190 14.24 376 1017 5.01 / 356.71 2 11
Average= 4.82 (KJ/cycle)

Cycle 72 GMT 2/10/2016 4:14: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.84 29 14.44 557 233 0.23 / 346.75 2 2
2 7 2007.60 51 11.25 3335 1913 2.15 / 348.66 2 2
3 13 1816.52 28 12.67 3107 1102 3.25 / 349.76 2 2
4 13 936.44 29 13.42 1854 722 3.97 / 350.48 2 2
5 13 55.36 29 14.43 473 198 4.17 / 350.68 2 2
6 14 -0.12 190 14.24 376 1017 5.19 / 351.70 2 4
Average= 4.82 (KJ/cycle)

Cycle 71 GMT 22/ 9/2016 3:38: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.24 28 14.48 551 223 0.22 / 341.64 2 2
2 3 1027.96 1 13.28 1942 26 0.25 / 341.66 2 2
3 7 2003.72 50 11.41 3349 1911 2.16 / 343.57 2 2
4 13 1605.64 28 12.85 2835 1020 3.18 / 344.59 2 2
5 13 962.04 29 13.40 1890 734 3.91 / 345.33 2 2
6 13 23.64 29 14.46 415 174 4.09 / 345.50 2 2
7 14 -0.08 190 14.22 374 1010 5.10 / 346.51 2 7
Average= 4.81 (KJ/cycle)

Cycle 70 GMT 12/ 9/2016 3: 7: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.08 28 14.45 559 226 0.23 / 336.65 2 2
2 7 2000.44 50 11.42 3364 1921 2.15 / 338.57 2 2
3 13 1607.60 28 12.82 2836 1018 3.17 / 339.59 2 2
4 13 770.76 28 13.58 1599 608 3.77 / 340.20 2 2
5 13 73.20 28 14.40 493 199 3.97 / 340.40 2 2
6 14 -0.08 190 14.26 375 1016 4.99 / 341.41 2 8
Average= 4.81 (KJ/cycle)

Cycle 69 GMT 2/ 9/2016 2:19:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.24 28 14.47 536 217 0.22 / 331.59 2 2
2 7 2002.68 50 11.48 3374 1937 2.15 / 333.53 2 2
3 13 1617.12 28 12.82 2846 1022 3.18 / 334.55 2 2
4 13 953.72 28 13.40 1892 710 3.89 / 335.26 2 2
5 13 2.32 28 14.47 391 158 4.04 / 335.42 2 2
6 14 -0.08 190 14.20 374 1009 5.05 / 336.43 2 11
Average= 4.81 (KJ/cycle)

Cycle 68 GMT 23/ 8/2016 1:53: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.64 28 14.45 547 221 0.22 / 326.51 2 2
2 7 2001.72 50 11.59 3372 1954 2.18 / 328.46 2 2
3 13 1606.76 28 12.85 2836 1020 3.20 / 329.48 2 2
4 13 957.88 28 13.39 1904 714 3.91 / 330.19 2 2
5 13 1.04 28 14.45 395 160 4.07 / 330.35 2 2
6 14 0.08 190 14.16 379 1020 5.09 / 331.37 2 13
Average= 4.80 (KJ/cycle)

Cycle 67 GMT 13/ 8/2016 1:41: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.44 28 14.40 566 228 0.23 / 321.64 2 2
2 7 2006.48 50 11.68 3325 1942 2.17 / 323.58 2 2
3 13 1416.00 28 13.01 2556 931 3.10 / 324.51 2 2
4 13 1001.80 28 13.39 1972 739 3.84 / 325.25 2 2
5 14 -0.04 190 14.20 384 1036 4.88 / 326.29 2 9
Average= 4.80 (KJ/cycle)

Cycle 66 GMT 3/ 8/2016 0:45: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.56 29 14.48 527 221 0.22 / 316.72 2 2
2 3 929.92 -1 14.48 527 0 0.00 / 316.72 2 2
3 7 2003.36 51 11.74 3325 1991 2.21 / 318.72 2 2
4 13 1576.36 29 12.91 2770 1037 3.25 / 319.75 2 2
5 13 713.04 29 13.63 1529 604 3.85 / 320.36 2 2
6 14 0.04 190 14.19 390 1051 4.91 / 321.41 2 12
Average= 4.80 (KJ/cycle)

Cycle 65 GMT 23/ 7/2016 23:43: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.68 30 14.50 546 238 0.24 / 311.78 2 2
2 3 933.28 -1 14.50 546 0 0.00 / 311.78 2 2
3 7 2008.96 50 11.69 3334 1949 2.19 / 313.73 2 2
4 13 1589.04 28 12.93 2765 1001 3.19 / 314.73 2 2
5 13 717.60 28 13.69 1528 586 3.77 / 315.32 2 2
6 13 23.68 29 14.44 425 178 3.95 / 315.49 2 2
7 14 -0.08 190 14.21 374 1010 4.96 / 316.50 2 13
Average= 4.80 (KJ/cycle)

Cycle 64 GMT 13/ 7/2016 22:51: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.24 29 14.53 552 233 0.23 / 306.55 2 2
2 3 1045.44 1 13.59 1958 27 0.26 / 306.57 2 2
3 7 2005.92 51 11.81 3323 2001 2.26 / 308.57 2 2
4 13 1601.64 29 12.96 2816 1058 3.32 / 309.63 2 2
5 13 932.00 28 13.52 1849 700 4.02 / 310.33 2 2
6 13 86.40 28 14.43 513 207 4.23 / 310.54 2 2
7 14 -0.04 190 14.30 369 1003 5.23 / 311.54 2 10
Average= 4.79 (KJ/cycle)

Cycle 63 GMT 3/ 7/2016 22:18: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.68 30 14.53 535 233 0.23 / 301.38 2 2
2 3 947.32 -1 14.53 535 0 0.00 / 301.38 2 2
3 3 1027.00 1 13.45 1918 26 0.26 / 301.41 2 2
4 7 2012.32 51 11.83 3351 2022 2.28 / 303.43 2 2
5 13 1606.96 29 12.97 2826 1063 3.34 / 304.49 2 2
6 13 754.44 29 13.72 1569 624 3.97 / 305.12 2 2
7 13 52.80 29 14.48 457 192 4.16 / 305.31 2 2
8 14 0.04 190 14.29 370 1005 5.16 / 306.31 2 7
Average= 4.79 (KJ/cycle)

Cycle 62 GMT 23/ 6/2016 21:46: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.20 29 14.55 545 230 0.23 / 296.50 2 2
2 7 2004.12 51 11.92 3317 2016 2.25 / 298.52 2 2
3 13 1433.20 29 13.16 2544 971 3.22 / 299.49 2 2
4 13 800.48 29 13.70 1639 651 3.87 / 300.14 2 2
5 14 -0.20 190 14.33 370 1007 4.88 / 301.15 2 6
Average= 4.78 (KJ/cycle)

Cycle 61 GMT 13/ 6/2016 21: 5: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.52 30 14.55 529 231 0.23 / 291.61 2 2
2 3 949.84 -1 14.55 529 0 0.00 / 291.61 2 2
3 3 1026.72 1 13.40 1943 26 0.26 / 291.64 2 2
4 7 2004.16 50 11.97 3380 2023 2.28 / 293.66 2 2
5 13 1589.56 28 13.04 2811 1026 3.31 / 294.69 2 2
6 13 715.24 28 13.79 1500 579 3.89 / 295.27 2 2
7 14 0.04 190 14.33 370 1007 4.89 / 296.27 2 11
Average= 4.78 (KJ/cycle)

Cycle 60 GMT 3/ 6/2016 20:41: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.16 29 14.59 540 228 0.23 / 286.70 2 2
2 7 2002.88 50 12.07 3352 2023 2.25 / 288.72 2 2
3 13 1591.08 29 13.05 2820 1067 3.32 / 289.79 2 2
4 13 705.00 28 13.80 1487 575 3.89 / 290.37 2 2
5 14 -0.04 190 14.33 373 1016 4.91 / 291.38 2 4
Average= 4.78 (KJ/cycle)

Cycle 59 GMT 24/ 5/2016 20: 9: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.72 30 14.59 535 234 0.23 / 281.73 2 2
2 3 955.96 -1 14.59 535 0 0.00 / 281.73 2 2
3 3 1035.60 1 13.60 1948 26 0.26 / 281.76 2 2
4 7 2006.24 50 12.12 3374 2045 2.31 / 283.81 2 2
5 13 1596.60 29 13.06 2823 1069 3.37 / 284.88 2 2
6 13 719.96 28 13.80 1510 583 3.96 / 285.46 2 2
7 14 0.00 190 14.34 372 1014 4.97 / 286.47 2 6
Average= 4.77 (KJ/cycle)

Cycle 58 GMT 14/ 5/2016 19:35: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.60 30 14.60 531 233 0.23 / 276.80 2 2
2 7 2001.64 51 12.29 3331 2088 2.32 / 278.88 2 2
3 13 1420.08 29 13.24 2514 965 3.29 / 279.85 2 2
4 13 763.88 29 13.77 1584 633 3.92 / 280.48 2 2
5 14 0.24 190 14.35 374 1020 4.94 / 281.50 2 8
Average= 4.77 (KJ/cycle)

Cycle 57 GMT 4/ 5/2016 19: 5: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.04 30 14.60 526 230 0.23 / 271.68 2 2
2 3 969.64 -1 14.60 526 0 0.00 / 271.68 2 2
3 3 1046.04 1 13.76 1943 27 0.26 / 271.71 2 2
4 7 2005.04 50 12.38 3374 2089 2.35 / 273.80 2 2
5 13 1587.92 28 13.14 2801 1031 3.38 / 274.83 2 2
6 13 674.88 28 13.92 1429 557 3.93 / 275.38 2 2
7 13 21.56 28 14.57 415 169 4.10 / 275.55 2 2
8 14 -0.24 190 14.32 371 1009 5.11 / 276.56 2 6
Average= 4.77 (KJ/cycle)

Cycle 56 GMT 24/ 4/2016 18:56: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.56 30 14.60 530 232 0.23 / 266.75 2 2
2 7 2001.08 50 12.49 3338 2085 2.32 / 268.84 2 2
3 13 1584.64 28 13.16 2800 1032 3.35 / 269.87 2 2
4 13 706.60 28 13.89 1489 579 3.93 / 270.45 2 2
5 14 -0.12 190 14.38 367 1003 4.93 / 271.45 2 8
Average= 4.76 (KJ/cycle)

Cycle 55 GMT 14/ 4/2016 18:42: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.92 30 14.64 543 238 0.24 / 261.94 2 2
2 7 2003.48 50 12.53 3378 2116 2.35 / 264.05 2 2
3 13 1409.16 28 13.28 2556 950 3.31 / 265.00 2 2
4 13 567.32 28 14.04 1271 500 3.80 / 265.50 2 2
5 14 -0.08 190 14.39 372 1017 4.82 / 266.52 2 9
Average= 4.76 (KJ/cycle)

Cycle 54 GMT 4/ 4/2016 17:55: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.20 28 14.64 530 217 0.22 / 256.79 2 2
2 3 1042.24 1 13.84 1986 27 0.24 / 256.82 2 2
3 7 2007.00 51 12.59 3433 2204 2.45 / 259.02 2 2
4 13 1595.56 29 13.20 2822 1080 3.53 / 260.10 2 2
5 13 705.76 28 13.88 1500 583 4.11 / 260.69 2 2
6 14 -0.08 190 14.40 370 1012 5.12 / 261.70 2 8
Average= 4.76 (KJ/cycle)

Cycle 53 GMT 25/ 3/2016 17:26: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.44 30 14.65 526 231 0.23 / 251.83 2 2
2 3 938.72 -1 14.65 526 0 0.00 / 251.83 2 2
3 7 2002.88 50 12.36 3370 2083 2.31 / 253.92 2 2
4 13 1596.08 29 13.10 2811 1068 3.38 / 254.98 2 2
5 13 707.48 28 13.82 1503 582 3.96 / 255.57 2 2
6 14 0.04 190 14.38 369 1008 4.97 / 256.57 2 7
Average= 4.75 (KJ/cycle)

Cycle 52 GMT 15/ 3/2016 17: 5: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.68 30 14.63 544 239 0.24 / 246.69 2 2
2 3 966.52 -1 14.63 544 0 0.00 / 246.69 2 2
3 3 1035.60 1 13.81 1944 27 0.27 / 246.72 2 2
4 7 2003.04 51 12.26 3378 2112 2.38 / 248.83 2 2
5 13 1400.16 28 13.21 2542 940 3.32 / 249.77 2 2
6 13 756.48 29 13.71 1602 637 3.95 / 250.41 2 2
7 13 25.28 29 14.56 418 176 4.13 / 250.59 2 2
8 14 -0.36 190 14.30 374 1016 5.15 / 251.60 2 10
Average= 4.75 (KJ/cycle)

Cycle 51 GMT 5/ 3/2016 16:11: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.20 30 14.64 537 236 0.24 / 241.64 2 2
2 7 2002.72 50 12.48 3352 2092 2.33 / 243.73 2 2
3 13 1390.72 28 13.28 2533 942 3.27 / 244.67 2 2
4 13 734.48 28 13.86 1545 600 3.87 / 245.27 2 2
5 13 42.84 29 14.58 445 188 4.06 / 245.46 2 2
6 14 0.04 190 14.35 366 998 5.06 / 246.45 2 9
Average= 4.74 (KJ/cycle)

Cycle 50 GMT 24/ 2/2016 15:39: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.60 28 14.66 532 218 0.22 / 236.71 2 2
2 3 1047.96 1 14.08 1945 27 0.25 / 236.73 2 2
3 7 2002.44 50 12.50 3333 2083 2.33 / 238.82 2 2
4 13 1401.64 29 13.32 2468 953 3.28 / 239.77 2 2
5 13 756.76 28 13.85 1546 600 3.88 / 240.37 2 2
6 14 -0.12 190 14.39 377 1031 4.91 / 241.40 2 7
Average= 4.73 (KJ/cycle)

Cycle 49 GMT 14/ 2/2016 15:10: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.80 29 14.69 522 222 0.22 / 231.44 2 2
2 3 939.44 -1 14.69 522 0 0.00 / 231.44 2 2
3 7 2007.52 50 12.52 3345 2094 2.32 / 233.54 2 2
4 13 1593.40 28 13.22 2736 1013 3.33 / 234.55 2 2
5 13 707.32 28 13.94 1471 574 3.90 / 235.13 2 2
6 13 36.60 29 14.60 438 185 4.09 / 235.31 2 2
7 13 8.24 29 14.54 394 166 4.25 / 235.48 2 3
8 14 -0.12 190 14.33 371 1010 5.26 / 236.49 2 15
Average= 4.73 (KJ/cycle)

Cycle 48 GMT 4/ 2/2016 14:38: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.00 29 14.68 520 221 0.22 / 226.45 2 2
2 3 970.96 -1 14.68 520 0 0.00 / 226.45 2 2
3 3 1050.72 1 14.02 1961 27 0.25 / 226.48 2 2
4 7 2003.76 50 12.54 3344 2097 2.35 / 228.58 2 2
5 13 1409.88 28 13.30 2565 955 3.30 / 229.53 2 2
6 13 577.36 28 14.06 1296 510 3.81 / 230.04 2 2
7 13 24.44 28 14.62 423 173 3.98 / 230.21 2 2
8 14 -0.12 190 14.35 370 1009 4.99 / 231.22 2 14
Average= 4.72 (KJ/cycle)

Cycle 47 GMT 25/ 1/2016 13:50: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.20 28 14.70 525 216 0.22 / 221.28 2 2
2 3 1041.52 1 14.13 1947 28 0.24 / 221.31 2 2
3 3 1020.96 1 13.86 1939 27 0.27 / 221.33 2 2
4 7 2004.32 50 12.53 3368 2110 2.38 / 223.44 2 2
5 13 1569.48 28 13.21 2795 1034 3.41 / 224.48 2 2
6 13 655.48 28 13.96 1422 556 3.97 / 225.03 2 2
7 13 29.20 28 14.61 434 178 4.15 / 225.21 2 2
8 14 -0.20 190 14.36 373 1018 5.17 / 226.23 2 11
Average= 4.71 (KJ/cycle)

Cycle 46 GMT 15/ 1/2016 13:32: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.72 28 14.73 509 210 0.21 / 216.20 2 2
2 7 2009.24 50 12.54 3342 2095 2.31 / 218.30 2 2
3 13 1585.20 28 13.24 2717 1007 3.31 / 219.31 2 2
4 13 703.56 28 13.96 1421 555 3.87 / 219.86 2 2
5 13 16.88 28 14.64 393 161 4.03 / 220.02 2 2
6 14 0.00 190 14.35 382 1042 5.07 / 221.06 2 7
Average= 4.70 (KJ/cycle)

Cycle 45 GMT 5/ 1/2016 13: 9: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.28 29 14.69 527 225 0.22 / 211.12 2 2
2 3 954.36 -1 14.69 527 0 0.00 / 211.12 2 2
3 3 1022.68 1 13.82 1960 27 0.25 / 211.15 2 2
4 7 2005.84 50 12.53 3382 2119 2.37 / 213.27 2 2
5 13 1391.24 28 13.33 2517 939 3.31 / 214.21 2 2
6 13 749.68 28 13.87 1579 613 3.92 / 214.82 2 2
7 13 23.48 28 14.63 416 170 4.09 / 214.99 2 2
8 14 -0.12 190 14.36 367 1001 5.09 / 215.99 2 9
Average= 4.70 (KJ/cycle)

Cycle 44 GMT 26/12/2015 12:43: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.48 29 14.69 524 223 0.22 / 205.86 2 2
2 3 972.12 -1 14.69 524 0 0.00 / 205.86 2 2
3 3 1030.80 1 14.04 1970 28 0.25 / 205.89 2 2
4 7 2003.40 51 12.58 3359 2155 2.41 / 208.05 2 2
5 13 1576.56 29 13.24 2776 1066 3.47 / 209.11 2 2
6 13 667.60 29 13.90 1463 590 4.06 / 209.70 2 2
7 13 33.64 28 14.61 434 178 4.24 / 209.88 2 2
8 14 -0.08 190 14.35 374 1020 5.26 / 210.90 2 10
Average= 4.69 (KJ/cycle)

Cycle 43 GMT 16/12/2015 12:18:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.12 28 14.71 522 215 0.22 / 200.87 2 2
2 3 1039.00 1 14.28 2026 29 0.24 / 200.90 2 2
3 7 2001.60 50 12.64 3378 2135 2.38 / 203.03 2 2
4 13 1578.32 28 13.27 2777 1032 3.41 / 204.07 2 2
5 13 645.72 28 13.96 1425 557 3.97 / 204.62 2 2
6 14 -0.16 190 14.39 372 1017 4.98 / 205.64 2 9
Average= 4.67 (KJ/cycle)

Cycle 42 GMT 6/12/2015 11:41: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.40 29 14.69 527 225 0.22 / 195.95 2 2
2 3 947.48 -1 14.69 527 0 0.00 / 195.95 2 2
3 7 2001.68 51 12.93 3371 2223 2.45 / 198.17 2 2
4 13 1401.48 29 13.46 2527 986 3.43 / 199.16 2 2
5 13 546.72 28 14.09 1263 498 3.93 / 199.66 2 2
6 14 -0.16 190 14.44 363 996 4.93 / 200.66 2 8
Average= 4.67 (KJ/cycle)

Cycle 41 GMT 26/11/2015 11: 2: 3

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.52 29 14.69 519 221 0.22 / 191.07 2 2
2 7 2002.20 30 12.93 3384 1313 1.53 / 192.39 2 2
3 13 1834.96 20 13.24 3177 841 2.38 / 193.23 2 2
4 13 1619.04 20 13.41 2857 766 3.14 / 193.99 2 2
5 13 914.28 20 13.85 1855 514 3.66 / 194.51 2 2
6 13 209.96 20 14.48 727 211 3.87 / 194.72 2 2
7 14 0.00 190 14.40 369 1010 4.88 / 195.73 2 8
Average= 4.66 (KJ/cycle)

Cycle 40 GMT 16/11/2015 10:18:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.72 29 14.67 537 228 0.23 / 185.96 2 2
2 7 2001.64 30 12.98 3396 1322 1.55 / 187.29 2 2
3 13 1825.80 20 13.26 3165 839 2.39 / 188.13 2 2
4 13 1609.72 21 13.42 2857 805 3.20 / 188.93 2 2
5 13 1146.32 20 13.72 2177 597 3.79 / 189.53 2 2
6 13 428.64 20 14.28 1081 309 4.10 / 189.84 2 3
7 14 -0.16 190 14.40 371 1015 5.12 / 190.85 2 8
Average= 4.65 (KJ/cycle)

Cycle 39 GMT 6/11/2015 9:38:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.84 27 14.68 532 211 0.21 / 181.18 2 2
2 3 1048.84 1 14.46 2014 29 0.24 / 181.21 2 2
3 7 2005.80 30 13.01 3360 1311 1.55 / 182.52 2 2
4 13 1821.24 20 13.30 3086 821 2.37 / 183.34 2 2
5 13 1402.12 20 13.58 2481 674 3.05 / 184.01 2 2
6 13 962.40 20 13.87 1845 512 3.56 / 184.53 2 2
7 13 139.84 20 14.56 616 179 3.74 / 184.71 2 2
8 14 -0.16 190 14.41 376 1029 4.77 / 185.74 2 6
Average= 4.64 (KJ/cycle)

Cycle 38 GMT 27/10/2015 9: 8: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.68 29 14.64 537 228 0.23 / 176.23 2 2
2 3 968.40 -1 14.64 537 0 0.00 / 176.23 2 2
3 7 2008.76 30 13.06 3387 1327 1.56 / 177.55 2 2
4 13 1827.40 20 13.29 3155 839 2.39 / 178.39 2 2
5 13 1626.20 20 13.43 2887 775 3.17 / 179.17 2 2
6 13 959.52 21 13.86 1910 556 3.72 / 179.72 2 2
7 13 268.40 20 14.45 818 236 3.96 / 179.96 2 2
8 14 0.04 190 14.43 368 1009 4.97 / 180.97 2 8
Average= 4.64 (KJ/cycle)

Cycle 37 GMT 17/10/2015 8:59: 3

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.60 29 14.67 529 225 0.23 / 171.32 2 2
2 7 2006.04 30 13.16 3396 1341 1.57 / 172.66 2 2
3 13 1814.04 20 13.33 3127 834 2.40 / 173.49 2 2
4 13 1599.68 20 13.47 2855 769 3.17 / 174.26 2 2
5 13 892.96 20 13.92 1813 505 3.67 / 174.77 2 2
6 13 207.56 20 14.52 717 208 3.88 / 174.98 2 2
7 14 0.08 190 14.41 373 1021 4.90 / 176.00 2 6
Average= 4.63 (KJ/cycle)

Cycle 36 GMT 7/10/2015 8:40: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.84 29 14.67 531 226 0.23 / 166.21 2 2
2 7 2002.96 30 13.22 3388 1344 1.57 / 167.55 2 2
3 13 1823.08 20 13.36 3150 842 2.41 / 168.40 2 2
4 13 1604.56 20 13.50 2854 771 3.18 / 169.17 2 2
5 13 1123.88 20 13.78 2148 592 3.77 / 169.76 2 2
6 13 393.44 21 14.33 1031 310 4.08 / 170.07 2 3
7 14 -0.08 190 14.40 375 1026 5.11 / 171.10 2 11
Average= 4.62 (KJ/cycle)

Cycle 35 GMT 27/ 9/2015 8:27: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.00 29 14.66 530 225 0.23 / 161.20 2 2
2 7 2003.12 30 13.15 3423 1350 1.58 / 162.55 2 2
3 13 1843.20 20 13.39 3176 851 2.43 / 163.40 2 2
4 13 1641.24 20 13.51 2899 783 3.21 / 164.18 2 2
5 13 959.04 21 13.91 1913 559 3.77 / 164.74 2 2
6 13 273.48 20 14.46 830 240 4.01 / 164.98 2 2
7 14 0.08 190 14.43 366 1003 5.01 / 165.99 2 10
Average= 4.61 (KJ/cycle)

Cycle 34 GMT 17/ 9/2015 8:10: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.20 29 14.63 546 232 0.23 / 156.16 2 2
2 7 2009.72 31 13.34 3375 1396 1.63 / 157.55 2 2
3 13 1833.36 21 13.41 3149 887 2.51 / 158.44 2 2
4 13 1613.60 21 13.52 2833 804 3.32 / 159.25 2 2
5 13 929.12 20 13.93 1852 516 3.83 / 159.76 2 2
6 13 214.96 20 14.52 721 209 4.04 / 159.97 2 3
7 14 -0.08 190 14.41 366 1002 5.05 / 160.97 2 9
Average= 4.60 (KJ/cycle)

Cycle 33 GMT 7/ 9/2015 8: 5: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.84 28 14.66 520 213 0.21 / 151.20 2 2
2 7 2005.52 30 13.21 3409 1351 1.56 / 152.55 2 2
3 13 1821.48 20 13.38 3175 850 2.41 / 153.40 2 2
4 13 1619.00 20 13.51 2862 773 3.19 / 154.17 2 2
5 13 919.72 20 13.92 1858 517 3.70 / 154.69 2 2
6 13 230.00 20 14.49 763 221 3.93 / 154.91 2 2
7 14 -0.08 190 14.41 371 1016 4.94 / 155.93 2 11
Average= 4.59 (KJ/cycle)

Cycle 32 GMT 28/ 8/2015 7:52: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.56 28 14.67 532 219 0.22 / 146.30 2 2
2 7 2014.40 30 13.30 3408 1360 1.58 / 147.66 2 2
3 13 1849.84 20 13.33 3202 854 2.43 / 148.52 2 2
4 13 1410.64 20 13.61 2570 700 3.13 / 149.22 2 2
5 13 967.48 20 13.88 1931 536 3.67 / 149.75 2 2
6 13 258.16 20 14.48 801 232 3.90 / 149.98 2 3
7 14 0.04 190 14.40 366 1001 4.90 / 150.99 2 11
Average= 4.58 (KJ/cycle)

Cycle 31 GMT 18/ 8/2015 7:17: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.64 28 14.67 515 212 0.21 / 141.28 2 2
2 7 2005.16 30 13.31 3375 1348 1.56 / 142.63 2 2
3 13 1832.92 20 13.35 3184 850 2.41 / 143.48 2 2
4 13 1632.24 20 13.49 2873 775 3.18 / 144.25 2 2
5 13 1151.92 20 13.78 2185 602 3.79 / 144.85 2 2
6 13 206.40 21 14.52 721 220 4.01 / 145.07 2 3
7 14 -0.24 190 14.40 370 1012 5.02 / 146.09 2 4
Average= 4.57 (KJ/cycle)

Cycle 30 GMT 8/ 8/2015 7: 5: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.20 28 14.68 524 215 0.22 / 136.43 2 2
2 7 2005.96 30 13.31 3383 1351 1.57 / 137.78 2 2
3 13 1838.44 20 13.35 3161 844 2.41 / 138.63 2 2
4 13 1408.32 20 13.63 2543 693 3.10 / 139.32 2 2
5 13 952.60 20 13.91 1883 524 3.63 / 139.84 2 2
6 13 254.16 20 14.48 792 229 3.86 / 140.07 2 3
7 14 0.08 190 14.42 363 995 4.85 / 141.07 2 8
Average= 4.55 (KJ/cycle)

Cycle 29 GMT 29/ 7/2015 6:46: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.68 28 14.70 512 211 0.21 / 131.49 2 2
2 7 2003.52 30 13.32 3369 1346 1.56 / 132.84 2 2
3 13 1835.36 20 13.35 3183 850 2.41 / 133.69 2 2
4 13 1397.88 20 13.63 2541 693 3.10 / 134.38 2 2
5 13 938.24 20 13.92 1869 520 3.62 / 134.90 2 2
6 13 221.52 21 14.53 736 225 3.84 / 135.12 2 3
7 13 2.48 21 14.74 378 117 3.96 / 135.24 2 3
8 14 -0.32 190 14.39 356 973 4.93 / 136.22 2 10
Average= 4.54 (KJ/cycle)

Cycle 28 GMT 19/ 7/2015 6: 9: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.64 28 14.73 488 201 0.20 / 126.52 2 2
2 7 2000.84 30 13.33 3358 1343 1.54 / 127.87 2 2
3 13 1810.40 20 13.37 3115 833 2.38 / 128.70 2 2
4 13 1594.12 20 13.51 2820 762 3.14 / 129.46 2 2
5 13 889.80 20 13.95 1796 501 3.64 / 129.96 2 2
6 13 413.84 21 14.34 1053 317 3.96 / 130.28 2 3
7 14 0.12 190 14.42 365 1000 4.96 / 131.28 2 9
Average= 4.53 (KJ/cycle)

Cycle 27 GMT 9/ 7/2015 5:43: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.12 28 14.70 506 208 0.21 / 121.68 2 2
2 7 2004.80 31 13.38 3322 1378 1.59 / 123.06 2 2
3 13 1820.44 21 13.42 3056 861 2.45 / 123.92 2 2
4 13 1605.88 21 13.55 2760 785 3.23 / 124.70 2 2
5 13 698.92 20 14.14 1422 402 3.63 / 125.11 2 2
6 13 135.28 20 14.66 545 160 3.79 / 125.27 2 2
7 13 7.96 20 14.76 371 110 3.90 / 125.38 2 2
8 14 -0.16 190 14.41 346 947 4.85 / 126.32 2 14
Average= 4.51 (KJ/cycle)

Cycle 26 GMT 29/ 6/2015 5:10: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.44 28 14.72 509 210 0.21 / 116.88 2 2
2 7 2003.84 30 13.31 3374 1347 1.56 / 118.23 2 2
3 13 1829.52 20 13.36 3160 844 2.40 / 119.08 2 2
4 13 1392.56 20 13.63 2532 690 3.09 / 119.77 2 2
5 13 935.72 20 13.94 1850 516 3.61 / 120.28 2 2
6 13 212.76 20 14.54 717 209 3.82 / 120.49 2 3
7 14 -0.04 191 14.43 356 981 4.80 / 121.47 2 9
Average= 4.50 (KJ/cycle)

Cycle 25 GMT 19/ 6/2015 4:37: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.04 28 14.77 486 201 0.20 / 112.18 2 2
2 7 2005.00 31 13.31 3333 1375 1.58 / 113.55 2 2
3 13 1811.16 21 13.40 3042 856 2.43 / 114.41 2 2
4 13 1364.60 20 13.70 2404 659 3.09 / 115.07 2 2
5 13 909.16 20 13.97 1799 503 3.59 / 115.57 2 2
6 13 92.00 20 14.67 514 151 3.74 / 115.72 2 3
7 14 0.04 190 14.44 347 952 4.70 / 116.67 2 10
Average= 4.49 (KJ/cycle)

Cycle 24 GMT 9/ 6/2015 4:12: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.44 28 14.76 479 198 0.20 / 107.10 2 2
2 7 2007.48 30 12.89 3581 1385 1.58 / 108.48 2 2
3 13 1849.92 20 13.41 3172 851 2.43 / 109.33 2 2
4 13 1639.48 20 13.53 2873 777 3.21 / 110.11 2 2
5 13 1169.04 20 13.81 2195 606 3.82 / 110.72 2 2
6 13 447.40 20 14.35 1095 314 4.13 / 111.03 2 3
7 14 -0.12 190 14.48 344 946 5.08 / 111.98 2 10
Average= 4.48 (KJ/cycle)

Cycle 23 GMT 30/ 5/2015 4: 5: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.96 28 14.79 486 201 0.20 / 102.34 2 2
2 7 2000.80 31 13.37 3315 1374 1.58 / 103.72 2 2
3 13 1818.60 20 13.42 3098 832 2.41 / 104.55 2 2
4 13 1388.40 21 13.68 2483 713 3.12 / 105.26 2 2
5 13 931.08 20 13.96 1823 509 3.63 / 105.77 2 2
6 13 225.56 20 14.57 715 208 3.84 / 105.98 2 3
7 14 -0.04 190 14.49 334 920 4.76 / 106.90 2 11
Average= 4.45 (KJ/cycle)

Cycle 22 GMT 20/ 5/2015 3:54: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.48 28 14.82 464 193 0.19 / 97.52 2 2
2 7 2006.16 30 13.27 3392 1350 1.54 / 98.87 2 2
3 13 1832.76 20 13.41 3115 835 2.38 / 99.70 2 2
4 13 1617.48 20 13.55 2797 758 3.14 / 100.46 2 2
5 13 928.64 20 13.97 1805 504 3.64 / 100.96 2 2
6 13 128.08 20 14.69 550 162 3.80 / 101.13 2 2
7 13 29.36 20 14.78 386 114 3.92 / 101.24 2 2
8 14 0.00 190 14.46 329 904 4.82 / 102.14 2 9
Average= 4.44 (KJ/cycle)

Cycle 21 GMT 10/ 5/2015 4:15: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.56 28 14.80 475 197 0.20 / 92.72 2 2
2 7 2003.04 30 13.27 3384 1347 1.54 / 94.07 2 2
3 13 1833.32 20 13.43 3094 831 2.38 / 94.90 2 2
4 13 1413.76 20 13.67 2509 686 3.06 / 95.59 2 2
5 13 961.96 20 13.95 1845 515 3.58 / 96.10 2 2
6 13 255.00 20 14.55 756 220 3.80 / 96.32 2 3
7 13 24.76 20 14.82 371 110 3.91 / 96.43 2 2
8 14 -0.12 190 14.49 323 889 4.79 / 97.32 2 11
Average= 4.42 (KJ/cycle)

Cycle 20 GMT 30/ 4/2015 4:39: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.20 28 14.81 474 197 0.20 / 87.89 2 2
2 7 2010.96 30 13.40 3303 1328 1.52 / 89.22 2 2
3 13 1827.36 20 13.43 3060 822 2.35 / 90.04 2 2
4 13 1608.32 20 13.55 2788 756 3.10 / 90.80 2 2
5 13 931.44 20 13.94 1835 512 3.61 / 91.31 2 2
6 13 227.80 20 14.57 714 208 3.82 / 91.52 2 3
7 13 48.60 20 14.77 416 123 3.94 / 91.64 2 2
8 14 -0.04 190 14.48 323 889 4.83 / 92.53 2 11
Average= 4.41 (KJ/cycle)

Cycle 19 GMT 20/ 4/2015 5:12: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.16 28 14.81 475 197 0.20 / 82.90 2 2
2 7 2005.68 30 13.09 3451 1355 1.55 / 84.26 2 2
3 13 1832.48 20 13.41 3077 825 2.38 / 85.08 2 2
4 13 1640.24 20 13.53 2836 767 3.14 / 85.85 2 2
5 13 1168.56 20 13.80 2171 599 3.74 / 86.45 2 2
6 13 219.16 20 14.58 708 206 3.95 / 86.66 2 3
7 13 48.24 20 14.79 415 123 4.07 / 86.78 2 2
8 14 0.08 191 14.48 331 915 4.99 / 87.70 2 8
Average= 4.38 (KJ/cycle)

Cycle 18 GMT 10/ 4/2015 5:43: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.36 28 14.82 465 193 0.19 / 78.06 2 2
2 7 2007.36 30 13.35 3317 1328 1.52 / 79.39 2 2
3 13 1808.16 20 13.36 3081 823 2.34 / 80.22 2 2
4 13 1593.92 20 13.51 2773 749 3.09 / 80.97 2 2
5 13 917.40 20 13.93 1814 505 3.60 / 81.47 2 2
6 13 215.20 20 14.56 703 205 3.80 / 81.68 2 3
7 13 43.40 20 14.78 409 121 3.92 / 81.80 2 2
8 14 -0.20 190 14.47 331 910 4.83 / 82.71 2 9
Average= 4.35 (KJ/cycle)

Cycle 17 GMT 31/ 3/2015 6:10: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.08 27 14.87 428 172 0.17 / 73.59 2 2
2 7 2012.60 30 13.37 3315 1330 1.50 / 74.92 2 2
3 13 1816.08 20 13.40 3028 812 2.31 / 75.73 2 2
4 13 1410.12 20 13.66 2461 672 2.99 / 76.41 2 2
5 13 755.84 20 14.09 1501 423 3.41 / 76.83 2 3
6 13 146.32 20 14.68 540 159 3.57 / 76.99 2 3
7 14 -0.08 190 14.54 320 884 4.45 / 77.87 2 8
Average= 4.33 (KJ/cycle)

Cycle 16 GMT 21/ 3/2015 6:13: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.60 27 14.86 467 187 0.19 / 68.99 2 2
2 7 2007.80 30 13.38 3314 1330 1.52 / 70.32 2 2
3 13 1811.36 20 13.41 3016 809 2.33 / 71.13 2 2
4 13 1593.72 20 13.55 2709 734 3.06 / 71.87 2 2
5 13 883.36 20 13.98 1699 475 3.54 / 72.34 2 3
6 13 159.60 20 14.68 554 163 3.70 / 72.50 2 3
7 13 30.80 20 14.83 346 103 3.80 / 72.61 2 2
8 14 0.00 190 14.53 295 814 4.62 / 73.42 2 12
Average= 4.32 (KJ/cycle)

Cycle 15 GMT 11/ 3/2015 6:27: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.16 27 14.85 456 183 0.18 / 64.26 2 2
2 7 2006.00 30 13.40 3314 1332 1.52 / 65.59 2 2
3 13 1836.64 20 13.40 3110 833 2.35 / 66.42 2 2
4 13 1410.00 20 13.63 2520 687 3.04 / 67.11 2 2
5 13 953.96 21 13.91 1866 545 3.58 / 67.65 2 2
6 13 119.28 20 14.73 531 156 3.74 / 67.81 2 3
7 13 13.76 20 14.85 357 106 3.84 / 67.92 2 2
8 14 0.28 190 14.49 323 889 4.73 / 68.81 2 10
Average= 4.30 (KJ/cycle)

Cycle 14 GMT 1/ 3/2015 6:49: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 27 14.84 472 189 0.19 / 59.48 2 2
2 7 2000.80 30 13.40 3304 1328 1.52 / 60.81 2 2
3 13 1822.64 20 13.38 3077 823 2.34 / 61.63 2 2
4 13 1386.32 20 13.63 2488 678 3.02 / 62.31 2 2
5 13 944.80 20 13.91 1849 514 3.53 / 62.82 2 2
6 13 120.76 20 14.73 528 156 3.69 / 62.98 2 3
7 13 29.76 20 14.82 380 113 3.80 / 63.09 2 2
8 13 16.96 20 14.74 354 104 3.91 / 63.20 2 3
9 14 -0.32 190 14.45 319 876 4.78 / 64.07 2 11
Average= 4.27 (KJ/cycle)

Cycle 13 GMT 19/ 2/2015 6:54: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.68 27 14.88 451 181 0.18 / 55.05 2 2
2 7 2002.44 30 13.40 3288 1322 1.50 / 56.38 2 2
3 13 1828.12 20 13.38 3049 816 2.32 / 57.19 2 2
4 13 1402.12 20 13.62 2446 666 2.99 / 57.86 2 2
5 13 714.16 21 14.10 1447 428 3.41 / 58.29 2 3
6 13 125.60 20 14.73 504 148 3.56 / 58.43 2 3
7 14 -0.20 190 14.55 310 857 4.42 / 59.29 2 10
Average= 4.24 (KJ/cycle)

Cycle 12 GMT 9/ 2/2015 6:57: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.80 27 14.87 446 179 0.18 / 50.44 2 2
2 7 2002.44 30 13.42 3298 1328 1.51 / 51.76 2 2
3 13 1830.60 20 13.40 3052 818 2.32 / 52.58 2 2
4 13 1416.88 20 13.63 2444 666 2.99 / 53.25 2 2
5 13 932.00 21 13.93 1766 517 3.51 / 53.76 2 2
6 13 221.84 20 14.62 654 191 3.70 / 53.96 2 3
7 13 46.04 20 14.84 373 111 3.81 / 54.07 2 2
8 14 0.08 190 14.53 292 806 4.62 / 54.87 2 11
Average= 4.22 (KJ/cycle)

Cycle 11 GMT 30/ 1/2015 7:18: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.72 27 14.92 422 170 0.17 / 45.83 2 2
2 7 2003.24 30 13.40 3297 1325 1.50 / 47.16 2 2
3 13 1818.36 21 13.39 3026 851 2.35 / 48.01 2 2
4 13 1384.16 20 13.63 2405 656 3.00 / 48.66 2 2
5 13 947.16 20 13.91 1789 498 3.50 / 49.16 2 2
6 13 224.76 20 14.61 663 194 3.69 / 49.35 2 3
7 13 48.40 20 14.83 372 110 3.80 / 49.46 2 2
8 14 -0.20 190 14.54 287 793 4.60 / 50.26 2 14
Average= 4.19 (KJ/cycle)

Cycle 10 GMT 20/ 1/2015 7:38: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.72 27 14.90 443 178 0.18 / 41.37 2 2
2 7 2001.80 30 13.41 3311 1332 1.51 / 42.71 2 2
3 13 1810.60 20 13.38 3034 812 2.32 / 43.52 2 2
4 13 1595.88 20 13.52 2728 738 3.06 / 44.26 2 2
5 13 865.60 20 13.97 1676 468 3.53 / 44.72 2 3
6 13 90.72 20 14.80 446 132 3.66 / 44.86 2 3
7 14 -0.08 190 14.55 291 804 4.46 / 45.66 2 7
Average= 4.15 (KJ/cycle)

Cycle 9 GMT 10/ 1/2015 7:42: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.56 27 14.88 433 174 0.17 / 36.90 2 2
2 7 2001.68 30 13.44 3289 1326 1.50 / 38.23 2 2
3 13 1815.88 20 13.39 3038 814 2.31 / 39.04 2 2
4 13 1379.12 20 13.61 2416 658 2.97 / 39.70 2 2
5 13 916.48 20 13.94 1751 488 3.46 / 40.19 2 2
6 13 209.52 20 14.66 641 188 3.65 / 40.37 2 3
7 14 -0.04 190 14.55 297 821 4.47 / 41.20 2 12
Average= 4.12 (KJ/cycle)

Cycle 8 GMT 31/12/2014 8: 5: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.64 27 14.89 433 174 0.17 / 32.41 2 2
2 7 2003.60 30 13.44 3297 1329 1.50 / 33.74 2 2
3 13 1817.60 20 13.39 3038 814 2.32 / 34.56 2 2
4 13 1383.56 20 13.61 2422 659 2.98 / 35.22 2 2
5 13 922.68 20 13.93 1759 490 3.47 / 35.71 2 3
6 13 200.64 21 14.66 631 194 3.66 / 35.90 2 3
7 14 -0.12 190 14.54 299 826 4.49 / 36.73 2 9
Average= 4.08 (KJ/cycle)

Cycle 7 GMT 21/12/2014 8:18: 3

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.52 27 14.87 438 176 0.18 / 27.48 2 2
2 7 2002.04 74 12.89 3283 3132 3.31 / 30.61 2 2
3 13 755.44 21 14.06 1496 442 3.75 / 31.05 2 3
4 13 144.56 20 14.73 533 157 3.91 / 31.21 2 3
5 14 -0.20 241 14.51 295 1032 4.94 / 32.24 2 15
Average= 4.03 (KJ/cycle)

Cycle 6 GMT 11/12/2014 8:25: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.80 27 14.87 449 180 0.18 / 22.48 2 2
2 7 2004.52 74 12.88 3286 3132 3.31 / 25.61 2 2
3 13 972.16 20 13.88 1829 508 3.82 / 26.11 2 2
4 13 130.68 20 14.75 510 150 3.97 / 26.27 2 3
5 14 0.08 241 14.49 297 1037 5.01 / 27.30 2 11
Average= 3.90 (KJ/cycle)

Cycle 5 GMT 1/12/2014 9: 2: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.08 24 14.87 447 160 0.16 / 17.34 2 2
2 3 1086.36 2 14.63 2008 59 0.22 / 17.40 2 2
3 7 2004.24 74 12.85 3252 3092 3.31 / 20.50 2 2
4 13 789.92 20 14.00 1547 433 3.74 / 20.93 2 3
5 13 316.00 20 14.51 812 236 3.98 / 21.16 2 3
6 13 4.96 20 14.89 313 93 4.07 / 21.26 2 3
7 14 -0.20 241 14.44 298 1037 5.11 / 22.30 2 20
Average= 3.72 (KJ/cycle)

Cycle 4 GMT 21/11/2014 8:25: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.92 27 14.80 455 182 0.18 / 13.06 2 2
2 3 972.96 -1 14.80 455 0 0.00 / 13.06 2 2
3 3 1034.24 1 14.58 1950 28 0.21 / 13.09 2 2
4 7 1514.04 75 13.16 2565 2532 2.74 / 15.62 2 2
5 13 784.92 20 14.02 1533 430 3.17 / 16.05 2 3
6 13 29.80 21 14.86 350 109 3.28 / 16.16 2 3
7 14 -0.04 240 14.45 295 1023 4.30 / 17.19 2 17
Average= 3.44 (KJ/cycle)

Cycle 3 GMT 20/11/2014 9:16: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.60 27 14.77 456 182 0.18 / 8.89 2 2
2 7 1504.56 75 13.12 2544 2503 2.69 / 11.39 2 2
3 13 570.76 20 14.18 1205 342 3.03 / 11.74 2 2
4 13 40.56 21 14.82 373 116 3.14 / 11.85 2 3
5 14 0.00 240 14.43 297 1029 4.17 / 12.88 2 16
Average= 3.22 (KJ/cycle)

Cycle 2 GMT 19/11/2014 9:49: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.76 24 14.73 441 156 0.16 / 4.62 2 2
2 10 1028.48 3 14.52 1904 83 0.24 / 4.70 2 2
3 7 1505.12 74 13.04 2543 2454 2.69 / 7.16 2 2
4 13 760.48 20 13.94 1500 418 3.11 / 7.58 2 2
5 13 33.08 20 14.77 361 107 3.22 / 7.68 2 2
6 14 -0.04 241 14.40 296 1027 4.24 / 8.71 2 18
Average= 2.90 (KJ/cycle)

Cycle 1 GMT 18/11/2014 10:42: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.88 27 14.72 420 167 0.17 / 1.60 2 2
2 3 971.88 -1 14.72 420 0 0.00 / 1.60 2 2
3 3 1053.68 1 14.05 1958 28 0.19 / 1.63 2 2
4 7 1031.36 74 13.23 1870 1831 2.03 / 3.46 2 2
5 14 -0.04 240 14.40 292 1009 3.03 / 4.46 2 12
Average= 2.23 (KJ/cycle)

Cycle 0 GMT 17/11/2014 23:16: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 87.04 26 14.42 387 145 0.15 / 0.15 2 2
2 7 93.72 75 14.31 392 421 0.57 / 0.57 2 2
3 14 0.16 240 14.53 248 865 1.43 / 1.43 2 11
Average= 1.43 (KJ/cycle)