SIO Argo Site:
Diagnostic/Engineering Data Page    



Serial= 3242 WMO= 5906946

Return

Link to WHOI figures

Link to Fleet Monitoring (Coriolis)

Field 1 Field 2 Field 3 Field 4

←PreviousNext→

Cycle 19 GMT 15/11/2024 20:39: 0

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 12 12 21 0 529 14692 17 7.27 15.36 15.22 10.43 10.77 11.29


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
93 195 300 205 0 -4.30 300 0.72 0.56 0.76 64 0.9


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1000.08 3.445 34.3140 1002.72 3.441 34.3146 2000.56 2.008 34.5944 0.64 18.026 5.6380


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2883 2934 0 0 0 0 1 0 2 0



Cycle 18 GMT 6/11/2024 1:13: 0

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 12 12 14 0 258 14900 17 7.27 15.37 15.22 10.45 10.73 11.26


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
92 195 300 191 1 37.60 300 0.32 0.28 0.47 64 0.9


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1010.08 3.410 34.3210 1013.16 3.409 34.3210 2002.12 2.010 34.5934 0.96 19.044 34.3190


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2888 2920 0 0 0 0 1 0 2 0



Cycle 17 GMT 27/10/2024 5:56: 0

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 12 12 19 0 380 14293 17 7.27 15.36 15.22 10.49 10.79 11.30


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
110 195 300 200 1 -13.40 304 0.16 0.28 0.47 64 0.8


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1004.72 3.382 34.3254 1007.72 3.392 34.3240 2002.36 1.981 34.5990 0.44 19.246 34.2686


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2885 2938 0 0 0 0 1 0 2 0



Cycle 16 GMT 17/10/2024 10:38:59

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 12 12 12 0 193 14960 17 7.25 15.34 15.24 10.47 10.74 11.18


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
110 165 300 193 0 -10.40 298 0.52 0.60 0.82 64 0.6


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1005.48 3.381 34.3252 1007.96 3.374 34.3268 2001.44 1.984 34.5976 0.52 21.403 30.3018


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2879 2937 0 0 0 0 1 0 2 0



Cycle 15 GMT 7/10/2024 15:20: 1

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 12 13 15 0 243 14390 16 7.26 15.36 15.24 10.55 10.72 11.17


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
110 165 300 191 1 -12.10 296 0.76 0.88 1.02 64 0.6


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1006.16 3.381 34.3250 1009.20 3.376 34.3262 2002.84 1.985 34.5974 0.88 21.682 11.2170


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2872 2916 0 0 0 0 1 0 2 0



Cycle 14 GMT 27/ 9/2024 20:11: 0

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 13 12 12 0 170 14376 17 7.27 15.37 15.26 10.47 10.68 11.13


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
110 165 300 191 1 36.20 293 0.88 0.88 1.02 64 0.6


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1003.52 3.403 34.3206 1006.04 3.390 34.3232 2000.52 2.002 34.5936 0.84 22.957 1.8426


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2859 2901 0 0 0 0 1 0 2 0



Cycle 13 GMT 18/ 9/2024 1: 5: 1

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 12 12 17 0 366 14226 17 7.27 15.37 15.26 10.49 10.64 11.10


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
110 165 300 193 0 -9.20 301 -0.12 0.16 0.12 64 0.6


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1008.52 3.410 34.3196 1010.52 3.396 34.3226 2004.40 1.985 34.5990 0.60 24.631 34.3610


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2862 2922 4 1 0 0 1 0 2 0



Cycle 12 GMT 8/ 9/2024 5:52: 1

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 12 12 12 0 132 14817 17 7.27 15.38 15.27 10.53 10.66 11.11


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
110 165 300 193 0 -5.30 300 0.04 0.00 0.16 64 0.6


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
997.40 3.455 34.3106 1000.04 3.440 34.3136 2001.36 2.012 34.5946 0.52 24.231 34.2192


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2861 2930 0 0 0 0 1 0 2 0



Cycle 11 GMT 29/ 8/2024 10:40: 0

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 12 12 12 0 166 14462 17 7.27 15.39 15.28 10.51 10.67 11.12


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
110 165 300 201 0 8.10 301 0.36 0.32 0.51 63 0.6


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1004.52 3.442 34.3128 1008.08 3.433 34.3148 2008.08 1.997 34.5970 0.64 24.131 33.9430


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2868 2920 0 0 0 0 1 0 2 0



Cycle 10 GMT 19/ 8/2024 15:26: 0

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 12 12 12 0 153 14501 17 7.26 15.37 15.28 10.53 10.71 11.16


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
110 165 300 190 1 34.40 300 -0.96 -1.00 -0.80 62 0.8


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1010.44 3.445 34.3132 1013.52 3.417 34.3188 2010.36 2.001 34.5978 0.60 22.767 34.0886


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2865 2917 0 0 0 0 1 0 2 0



Cycle 9 GMT 9/ 8/2024 20:13: 0

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 12 17 19 5 347 14769 17 7.28 15.40 15.29 10.51 10.72 11.18


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
110 165 300 181 1 -28.70 305 0.28 0.44 0.50 61 0.6


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1017.88 3.468 34.3080 1020.76 3.436 34.3144 2009.56 1.999 34.5968 0.56 22.121 34.4348


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2861 2924 0 0 0 0 1 0 2 0



Cycle 8 GMT 31/ 7/2024 0:46: 1

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 12 11 12 0 197 11368 17 7.26 15.39 15.30 10.55 10.69 11.12


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
110 165 300 191 0 1.50 294 -0.20 -0.12 -0.06 61 0.8


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1013.60 3.483 34.3046 1019.64 3.472 34.3070 2002.28 2.032 34.5898 0.60 24.176 34.3884


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2832 2891 3 1 0 0 1 0 2 0



Cycle 7 GMT 21/ 7/2024 3:44: 0

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 11 10 11 0 140 10340 17 7.28 15.40 15.29 10.56 10.71 11.17


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
111 165 300 183 0 -4.70 291 -0.16 -0.12 0.01 61 0.9


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1002.12 3.468 34.3070 1009.16 3.503 34.3004 1803.92 2.166 34.5620 0.56 22.783 34.4992


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2591 2650 0 0 0 0 1 0 1 0



Cycle 6 GMT 20/ 7/2024 2:58: 0

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 10 11 11 2 164 10208 17 7.27 15.39 15.29 10.55 10.73 11.17


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
110 165 300 187 0 5.10 290 0.04 0.08 0.22 61 0.9


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1000.20 3.497 34.3018 1002.76 3.518 34.2974 1785.52 2.182 34.5598 0.52 22.707 34.4834


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2567 2616 5 1 0 0 1 0 1 0



Cycle 5 GMT 19/ 7/2024 2:13: 0

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 10 9 12 0 225 8707 17 7.26 15.40 15.30 10.55 10.72 11.17


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
110 165 300 191 0 -11.10 291 0.24 0.32 0.37 61 1.4


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1004.52 3.499 34.3004 1005.00 3.513 34.2978 1502.52 2.530 34.4922 0.36 22.931 6.3330


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2224 2290 0 0 0 0 1 0 1 0



Cycle 4 GMT 18/ 7/2024 2:47: 0

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 9 10 10 0 117 8958 17 7.27 15.42 15.31 10.55 10.72 11.18


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
111 165 300 184 0 -7.10 290 -0.56 -0.52 -0.49 60 1.2


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
996.72 3.467 34.3070 1004.28 3.514 34.2980 1522.12 2.468 34.5012 0.48 22.675 34.5108


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2250 2303 0 0 0 0 1 0 1 0



Cycle 3 GMT 17/ 7/2024 3:13: 1

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 10 10 10 0 109 8604 17 7.26 15.41 15.30 10.55 10.74 11.20


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
110 165 300 186 1 -27.60 290 -0.20 -0.20 -0.15 60 1.4


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1003.04 3.495 34.3024 1002.92 3.485 34.3038 1502.20 2.514 34.4926 0.40 22.349 34.5000


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2227 2294 0 0 0 0 1 0 1 0



Cycle 2 GMT 16/ 7/2024 3:48: 1

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 10 7 10 0 260 8913 17 7.26 15.42 15.31 10.53 10.73 11.20


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
110 165 300 188 2 62.90 283 0.44 0.56 0.60 61 1.2


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
996.44 3.526 34.2942 998.16 3.529 34.2942 1522.84 2.497 34.4948 0.48 22.341 4.3528


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2250 2314 0 0 0 0 1 0 1 0



Cycle 1 GMT 15/ 7/2024 4:12: 0

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 7 3 3 4 72 4421 17 7.25 15.49 15.39 10.27 10.74 11.20


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
75 165 300 181 2 -39.70 283 -0.08 0.00 0.05 63 2.0


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
-999.00 -999.000 -999.0000 -999.00 -999.000 -999.0000 999.32 3.502 34.2992 0.48 21.709 34.4760


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
1587 1658 0 0 0 0 1 0 0 0



Cycle 0 GMT 14/ 7/2024 17:33: 1

#Eng #Pack SatTme (s) SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V1 (inHG) V2 (inHG) RH (%) CPUT (C) SPRX (db) SPRXL (db)
6 2 0 878 17 7.30 15.62 15.58 10.47 11.24 58 16.0 -0.04 -0.04


diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu) PmtoSf (s) PmSf (s) HPavgl (ma) HPmaxl (ma) ExcFlg ISRID AbrtCd
153.24 13.189 34.370 0.48 21.450 34.464 100 240 461 485 0 0 0


BTVcpu (V) BTvac (inHG) BTVple (V) BTavgl (mA) BTPsec (s) BTPvac (inHG) Vent (s/10) VentLD
7.30 9.81 15.59 220 418 6.86 0 0



Cycle -1 GMT 10/ 6/2024 20:49: 0

#Eng #Pack BTPCor (db) BTVcpu (V) BTVpmp (V) BTVple (V) BTavgl (mA) BTPsec (s) BTOVcb BTOVca BTvac (inHG) BTvacI (inHG) BTRH (%) BTCPUT (C)
6 4 0.28 7.30 15.69 15.59 220.00 418 2 174 9.81 11.12 55 27.2


BTSpt (txt) BTOV BTCV BTInt Fail
"___-0.03,_40.7502,__0.0164____" 0 0 6 0