SIO Argo Site:
Diagnostic/Engineering Data Page    



Serial= 8208 WMO= 5904379

Return

Link to WHOI figures

Link to Fleet Monitoring (Coriolis)

Field 1 Field 2 Field 3 Field 4

←PreviousNext→

Cycle 3 GMT 13/ 2/2014 4:39:58

#Eng #Pack #SentP #ConnP Parse SatTme SBscan SBsbad SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
4 10 10 12 1 249 12575 0 17 7.66 14.93 14.23 9.36 10.03 10.76


SPRX (db) SPRXL (db) PCorr (db) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu) PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s)
0.00 0.00 -999.00 1512.44 2.914 34.598 0.68 24.203 35.123 144 251 400 138


P0 (db) P1 (db) P2 (db) P3 (db) P5 (db) Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) SeekTm (s) SeekP (db) PP>TIP (s/10)
0.00 1012.00 1009.24 1007.20 -0.04 1011.00 4.587 34.541 1006.96 4.596 34.540 0 -5.00 274


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD
2544 2593 0 0 0 0 1



Cycle 2 GMT 12/ 2/2014 5:18: 6

#Eng #Pack #SentP #ConnP Parse SatTme SBscan SBsbad SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
4 10 10 3 0 62 12960 0 17 7.69 15.46 14.25 9.42 10.07 10.47


SPRX (db) SPRXL (db) PCorr (db) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu) PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s)
0.08 0.00 -999.00 1510.92 3.011 34.596 0.76 23.670 35.083 143 250 400 137


P0 (db) P1 (db) P2 (db) P3 (db) P5 (db) Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) SeekTm (s) SeekP (db) PP>TIP (s/10)
0.00 995.48 995.84 1000.16 0.00 1003.56 4.732 34.538 1004.24 4.593 34.542 0 6.20 270


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD
2542 2611 0 0 0 0 1



Cycle 1 GMT 5/ 2/2014 4:13:51

#Eng #Pack #SentP #ConnP Parse SatTme SBscan SBsbad SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
4 7 2 4 0 132 7388 0 17 7.69 15.46 14.26 9.49 9.99 10.48


SPRX (db) SPRXL (db) PCorr (db) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu) PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s)
-0.16 0.00 -999.00 1013.04 4.522 34.550 0.72 23.770 35.048 94 250 400 130


P0 (db) P1 (db) P2 (db) P3 (db) P5 (db) Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) SeekTm (s) SeekP (db) PP>TIP (s/10)
0.00 1023.48 1013.12 -999.00 0.04 -999.00 -999.000 -999.000 -999.00 -999.000 -999.000 1 -6.30 267


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD
1837 1911 0 0 0 0 1



Cycle 0 GMT 1/ 2/2014 15: 8: 1

#Eng #Pack SatTme (s) SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V1 (inHG) V2 (inHG) SPRX (db) SPRXL (db)
4 1 86 1137 17 7.69 15.18 14.41 9.80 10.58 -0.12 -0.12


diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu) PmtoSf (s) PmSf (s) P5 (db) HPavgl (ma) HPmaxl (ma) ExcFlg ISRID AbrtCd
104.12 14.910 35.057 0.80 23.456 35.057 119 251 -0.04 451 462 1 0 0


BTVcpu (V) BTvac (inHG) BTVple (V) BTavgl (mA) BTPsec (s) BTPvac (inHG) Vent (s) VentLD
7.70 9.94 14.40 297 387 0.00 0.00 0



Cycle -1 GMT 3/ 1/2014 17:51: 1

#Eng #Pack BTPCor (db) BTVcpu (V) BTVpmp (V) BTVple (V) BTavgl (mA) BTPsec (s) BTOVcb BTOVca BTvac (inHG) BTvacI (inHG) BTOV BTCV BTInt
4 4 0.00 7.70 15.50 14.40 297.00 387 0 0 9.94 11.12 0 0 0


BTSpt (txt) Fail
"___-0.12,_21.2227,__0.0000____" 0