SIO Argo Site:
Diagnostic/Engineering Data Page    



Serial= 7037 Iridium= 46694 WMO= 3900842     Return  


Field 1     Field 2     Field 3     Field 4    


Cycle 4

#Eng #Pack #PackP #Conn Parse SatTme SBscan SBsbad SBstat Vcpu (V) Vpmp (V) Vple (V) dV0 (inHG) dV1 (inHG) dV2 (inHG)
3 8 8 8 0 130 9386 0 17 7.84 14.93 13.77 10.29 10.65 11.37


SPRX (db) SPRXL (db) PCorr (db) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu) PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s)
-0.08 -0.08 0.10 1112.88 3.807 34.504 0.92 18.024 34.497 145 263 400 136


P0 (db) P1 (db) P2 (db) P3 (db) P5 (db) Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) SeekTm (s/10) SeekP (db) PP>TIP (s/10)
-0.08 984.76 988.04 997.40 0.08 992.40 4.178 34.474 995.68 4.181 34.475 0 3.20 269


HPavgL (ma) HPmaxL (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD
2004 2076 0 0 0 0 1



Cycle 3

#Eng #Pack #PackP #Conn Parse SatTme SBscan SBsbad SBstat Vcpu (V) Vpmp (V) Vple (V) dV0 (inHG) dV1 (inHG) dV2 (inHG)
3 8 8 9 0 152 9354 0 17 7.84 14.93 13.78 10.29 10.65 11.37


SPRX (db) SPRXL (db) PCorr (db) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu) PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s)
-0.08 -0.08 0.10 1096.84 3.829 34.502 0.72 18.210 34.502 145 263 500 126


P0 (db) P1 (db) P2 (db) P3 (db) P5 (db) Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) SeekTm (s/10) SeekP (db) PP>TIP (s/10)
-0.08 984.72 981.76 987.40 0.04 985.56 4.164 34.476 986.32 4.197 34.474 0 -2.90 269


HPavgL (ma) HPmaxL (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD
1939 2076 0 0 0 0 1



Cycle 2

#Eng #Pack #PackP #Conn Parse SatTme SBscan SBsbad SBstat Vcpu (V) Vpmp (V) Vple (V) dV0 (inHG) dV1 (inHG) dV2 (inHG)
3 8 7 12 0 244 9626 0 17 7.84 14.93 13.75 10.23 10.77 11.43


SPRX (db) SPRXL (db) PCorr (db) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu) PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s)
-0.04 -0.04 0.08 1083.60 3.920 34.494 0.84 17.622 34.495 170 236 400 125


P0 (db) P1 (db) P2 (db) P3 (db) P5 (db) Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) SeekTm (s/10) SeekP (db) PP>TIP (s/10)
-0.04 885.32 956.36 952.88 -0.12 957.96 4.218 34.456 954.64 4.226 34.464 31 71.00 269


HPavgL (ma) HPmaxL (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD
1928 2019 0 0 0 0 1



Cycle 1

#Eng #Pack #PackP #Conn Parse SatTme SBscan SBsbad SBstat Vcpu (V) Vpmp (V) Vple (V) dV0 (inHG) dV1 (inHG) dV2 (inHG)
3 7 2 2 0 55 7655 0 17 7.84 14.87 13.73 10.11 10.71 11.43


SPRX (db) SPRXL (db) PCorr (db) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu) PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s)
0.00 0.00 0.06 1013.44 4.135 34.478 0.80 17.554 34.477 120 258 500 128


P0 (db) P1 (db) P2 (db) P3 (db) P5 (db) Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) SeekTm (s/10) SeekP (db) PP>TIP (s/10)
0.00 1025.88 1013.32 1013.36 0.04 -999.00 -999.000 -999.000 -999.00 -999.000 -999.000 6 -12.50 262


HPavgL (ma) HPmaxL (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD
1843 1961 0 0 0 0 1



Cycle 0

#Eng #Pack SatTme (s) SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) dV1 (inHG) dV2 (inHG) SPRX (db) SPRXL (db)
3 1 155 1367 17 7.84 15.00 14.21 10.53 11.25 0.04 0.00


diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu) PmtoSf (s) PmSf (s) P5 (db) HPavgl (ma) HPmaxl (ma) ExcFlg ISRID AbrtCd
120.92 11.42 34.23 0.80 17.531 34.435 145 242 0.04 574 653 5469 0 0


BTVcpu (V) BTvac (inHG) BTVple (V) BTavgl (mA) BTPsec (s) BTPvac (inHG)
7.84 10.00 14.05 361 391 19.49



Cycle -1

#Eng #Pack BTPCor (db) BTVcpu (V) BTVpmp (V) BTVple (V) BTavgl (mA) BTPsec (s) BTOVcb BTOVca BTvac (inHG) BTvacI (inHG) BTOV BTCV BTInt
3 4 -15.09 7.84 15.43 14.05 361.00 391 7 157 10.00 11.13 0 0 5


BTSpt (txt)
"____0.04,_17.6184,__0.0090____"