Fld 1 Fld 2 Fld 3 Fld 4

←PreviousNext→


Cycle #Eng #Pack #SentP #ConnP Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG) RH (%) HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD
25 6 3 1 1 7.23 15.35 15.31 11.76 11.74 11.75 62 435 466 20 7
11 6 6 7 9 7.23 15.30 15.26 11.85 11.74 11.74 62 456 482 31 23
10 6 7 9 9 7.23 15.49 15.43 11.85 11.72 11.85 63 1081 1193 11 1
9 6 8 9 11 7.24 15.44 15.39 11.85 11.64 11.85 64 1822 1979 13 1
8 6 9 10 10 7.23 15.41 15.35 11.84 11.71 11.85 63 3293 3711 29 17
7 6 9 9 9 7.23 15.40 15.36 11.85 11.66 11.84 63 3114 3573 13 17
6 6 9 10 10 7.22 15.40 15.35 11.85 11.64 11.85 63 2926 3624 19 81
5 6 9 9 9 7.21 15.38 15.34 11.85 11.62 11.85 64 2619 3045 49 85
4 6 9 8 12 7.21 15.38 15.34 11.82 11.63 11.85 64 2572 3020 29 21
3 6 7 7 10 7.20 15.40 15.35 11.82 11.63 11.82 64 788 1182 14 17
2 6 7 7 12 7.19 15.42 15.37 11.81 11.62 11.82 64 755 1189 0 0
1 6 7 3 6 7.18 15.43 15.40 11.55 11.53 11.81 68 805 1176 0 0