SIO Argo Site:
Pump Diagnostics







Serial= 6126 - WMO= 7901078


Cycle 33 : GMT 17/ 8/2026 16:53: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 56.8 10 214 14.65 481 1508 1.51 / 466.62 2 25
2 6 3502.7 505 63 14.24 2714 2435 3.94 / 469.06 2 38
3 3 3171.1 626 9 14.45 2600 338 4.28 / 469.40 2 37
4 7 2855.0 12750 80 14.52 2355 2736 7.02 / 472.13 2 44
5 13 1980.8 12942 80 14.50 1812 2102 9.12 / 474.23 2 43
6 13 1334.1 13056 80 14.57 1396 1627 10.75 / 475.86 2 48
7 13 997.4 13104 80 14.58 1169 1364 12.11 / 477.23 2 49
8 13 731.1 13134 80 14.58 990 1155 13.26 / 478.38 2 46
9 14 0.1 13209 93 14.70 467 638 13.90 / 479.02 2 114
10 14 0.1 13209 7 14.69 451 46 13.95 / 479.06 54 144
Average= 14.09
(KJ/cycle)

Cycle 32 : GMT 8/ 8/2026 12:31: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 56.6 10 215 14.65 483 1521 1.52 / 452.78 2 24
2 6 3434.2 502 63 14.25 2685 2410 3.93 / 455.19 2 37
3 3 3108.3 623 5 14.50 2563 186 4.12 / 455.38 2 36
4 7 2884.0 12747 80 14.52 2376 2760 6.88 / 458.14 2 44
5 13 1990.8 12952 80 14.51 1796 2085 8.96 / 460.22 2 43
6 13 1468.6 13041 80 14.55 1469 1710 10.67 / 461.93 2 48
7 13 996.3 13108 80 14.60 1171 1368 12.04 / 463.30 2 48
8 13 730.9 13137 80 14.59 984 1149 13.19 / 464.45 2 46
9 14 0.3 13218 93 14.72 453 620 13.81 / 465.07 2 107
10 14 0.3 13218 7 14.70 449 46 13.85 / 465.12 37 130
Average= 14.09
(KJ/cycle)

Cycle 31 : GMT 30/ 7/2026 8: 1: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 73.0 12 212 14.65 505 1568 1.57 / 438.81 2 26
2 6 3485.7 506 63 14.23 2720 2438 4.01 / 441.25 2 37
3 3 3171.4 627 9 14.43 2605 338 4.35 / 441.59 2 37
4 7 2906.5 12751 80 14.52 2396 2783 7.13 / 444.37 2 43
5 13 1996.0 12955 80 14.52 1811 2104 9.23 / 446.48 2 44
6 13 1373.2 13063 80 14.58 1412 1647 10.88 / 448.13 2 47
7 13 950.7 13123 80 14.61 1130 1321 12.20 / 449.45 2 49
8 13 715.6 13150 80 14.60 977 1141 13.34 / 450.59 2 47
9 14 0.4 13227 95 14.72 459 642 13.98 / 451.23 2 113
10 14 0.5 13227 5 14.70 438 32 14.01 / 451.26 55 115
Average= 14.10
(KJ/cycle)

Cycle 30 : GMT 21/ 7/2026 3:22: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 57.7 10 214 14.65 494 1549 1.55 / 424.81 2 26
2 6 3391.5 494 63 14.25 2672 2399 3.95 / 427.21 2 38
3 3 3049.4 615 2 14.57 2615 76 4.02 / 427.29 2 33
4 7 2931.7 12739 80 14.51 2421 2810 6.83 / 430.10 2 44
5 13 2098.3 12926 80 14.50 1890 2192 9.03 / 432.29 2 45
6 13 1435.8 13040 80 14.56 1484 1729 10.75 / 434.02 2 47
7 13 975.5 13106 80 14.61 1176 1375 12.13 / 435.39 2 48
8 13 738.6 13132 80 14.60 1001 1169 13.30 / 436.56 2 46
9 14 0.0 13212 97 14.72 465 664 13.96 / 437.23 2 110
10 14 0.2 13212 3 14.70 451 20 13.98 / 437.25 49 80
Average= 14.10
(KJ/cycle)

Cycle 29 : GMT 11/ 7/2026 22:55: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 55.1 10 214 14.67 485 1523 1.52 / 410.94 2 25
2 6 3429.6 503 63 14.26 2687 2414 3.94 / 413.36 2 37
3 3 3103.5 624 5 14.50 2620 190 4.13 / 413.55 2 37
4 7 2899.5 12748 80 14.53 2390 2778 6.90 / 416.32 2 43
5 13 1996.7 12953 80 14.52 1827 2122 9.03 / 418.45 2 44
6 13 1236.6 13091 80 14.62 1347 1575 10.60 / 420.02 2 48
7 13 989.0 13127 80 14.60 1176 1374 11.98 / 421.39 2 48
8 13 731.2 13156 80 14.60 1008 1177 13.15 / 422.57 2 46
9 14 0.7 13236 93 14.72 472 646 13.80 / 423.22 2 100
10 14 0.7 13236 7 14.70 445 46 13.85 / 423.26 44 123
Average= 14.11
(KJ/cycle)

Cycle 28 : GMT 2/ 7/2026 18: 5: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 55.5 10 213 14.67 487 1522 1.52 / 396.90 2 24
2 6 3512.5 515 63 14.24 2753 2470 3.99 / 399.37 2 38
3 3 3143.2 636 7 14.47 2621 265 4.26 / 399.63 2 38
4 7 2882.6 12760 80 14.54 2384 2773 7.03 / 402.40 2 43
5 13 2015.7 12952 80 14.52 1867 2169 9.20 / 404.57 2 44
6 13 1336.2 13072 80 14.60 1415 1653 10.85 / 406.23 2 47
7 13 999.2 13120 80 14.61 1175 1373 12.22 / 407.60 2 48
8 13 707.9 13152 80 14.62 972 1137 13.36 / 408.74 2 45
9 14 -0.3 13229 95 14.73 463 648 14.01 / 409.38 2 111
10 14 -0.2 13229 5 14.71 481 35 14.04 / 409.42 55 117
Average= 14.12
(KJ/cycle)

Cycle 27 : GMT 23/ 6/2026 13:23: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 51.6 10 212 14.68 479 1491 1.49 / 382.96 2 24
2 6 3414.5 491 63 14.26 2695 2421 3.91 / 385.38 2 38
3 3 3101.4 612 5 14.52 2573 187 4.10 / 385.56 2 37
4 7 2942.7 12736 80 14.53 2426 2820 6.92 / 388.38 2 43
5 13 2073.7 12929 80 14.53 1870 2174 9.09 / 390.56 2 45
6 13 1312.6 13061 80 14.61 1384 1618 10.71 / 392.17 2 47
7 13 978.3 13109 80 14.62 1163 1360 12.07 / 393.53 2 49
8 13 726.6 13137 80 14.61 996 1164 13.23 / 394.70 2 47
9 14 0.1 13218 97 14.73 459 656 13.89 / 395.35 2 117
10 14 0.3 13218 3 14.72 433 19 13.91 / 395.37 49 84
Average= 14.12
(KJ/cycle)

Cycle 26 : GMT 14/ 6/2026 8:54: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 73.5 12 213 14.68 500 1563 1.56 / 369.05 2 24
2 6 3356.7 488 62 14.28 2633 2331 3.89 / 371.38 2 38
3 3 3082.9 609 4 14.53 2571 149 4.04 / 371.53 2 38
4 7 2967.5 12733 80 14.53 2434 2829 6.87 / 374.36 2 43
5 13 2059.8 12937 80 14.54 1858 2161 9.03 / 376.52 2 45
6 13 1456.3 13045 80 14.58 1493 1741 10.78 / 378.26 2 47
7 13 993.5 13111 80 14.63 1175 1375 12.15 / 379.64 2 49
8 13 716.0 13144 80 14.63 985 1153 13.30 / 380.79 2 45
9 14 0.3 13222 99 14.75 457 667 13.97 / 381.46 2 108
10 14 0.5 13222 1 14.72 444 7 13.98 / 381.46 56 82
Average= 14.13
(KJ/cycle)

Cycle 25 : GMT 5/ 6/2026 4:19: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 54.3 10 215 14.69 480 1516 1.52 / 355.25 2 25
2 6 3345.8 484 63 14.29 2646 2382 3.90 / 357.63 2 38
3 3 3030.0 604 1 14.61 2526 37 3.94 / 357.67 2 32
4 7 2927.8 12728 80 14.54 2408 2801 6.74 / 360.47 2 42
5 13 2014.7 12939 80 14.55 1831 2131 8.87 / 362.60 2 45
6 13 1362.5 13053 80 14.61 1423 1663 10.53 / 364.26 2 46
7 13 991.7 13107 80 14.64 1174 1375 11.91 / 365.64 2 48
8 13 731.3 13136 80 14.63 997 1167 13.07 / 366.80 2 46
9 14 0.0 13217 97 14.75 463 662 13.73 / 367.47 2 111
10 14 0.1 13217 3 14.74 482 21 13.76 / 367.49 54 80
Average= 14.13
(KJ/cycle)

Cycle 24 : GMT 26/ 5/2026 23:51: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 51.9 10 213 14.69 477 1493 1.49 / 341.19 2 25
2 6 3511.7 520 63 14.25 2765 2482 3.97 / 343.67 2 37
3 3 3165.0 641 8 14.46 2630 304 4.28 / 343.98 2 38
4 7 2852.1 12765 80 14.56 2374 2765 7.04 / 346.74 2 43
5 13 1989.1 12957 80 14.56 1822 2122 9.17 / 348.86 2 44
6 13 1324.4 13071 80 14.62 1395 1632 10.80 / 350.49 2 47
7 13 983.2 13119 80 14.63 1182 1383 12.18 / 351.88 2 48
8 13 740.3 13146 80 14.62 1005 1175 13.36 / 353.05 2 45
9 14 0.4 13225 93 14.75 460 631 13.99 / 353.68 2 109
10 14 0.4 13225 7 14.74 450 46 14.03 / 353.73 51 132
Average= 14.15
(KJ/cycle)

Cycle 23 : GMT 17/ 5/2026 19:13: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 50.4 10 212 14.68 494 1537 1.54 / 327.14 2 26
2 6 3448.4 497 63 14.26 2710 2435 3.97 / 329.57 2 38
3 3 3117.1 618 6 14.48 2599 226 4.20 / 329.80 2 38
4 7 2915.1 12742 80 14.55 2408 2803 7.00 / 332.60 2 44
5 13 1999.4 12953 80 14.57 1820 2121 9.12 / 334.72 2 45
6 13 1497.7 13037 80 14.58 1512 1764 10.89 / 336.48 2 48
7 13 993.0 13109 80 14.65 1172 1374 12.26 / 337.86 2 49
8 13 714.2 13141 80 14.64 987 1156 13.42 / 339.01 2 46
9 14 0.0 13218 95 14.75 463 649 14.06 / 339.66 2 111
10 14 0.0 13218 5 14.74 448 33 14.10 / 339.70 49 112
Average= 14.15
(KJ/cycle)

Cycle 22 : GMT 8/ 5/2026 14:40: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 54.4 10 214 14.69 483 1518 1.52 / 313.21 2 25
2 6 3389.1 496 63 14.29 2672 2406 3.92 / 315.61 2 38
3 3 3068.9 617 3 14.62 2578 113 4.04 / 315.72 2 32
4 7 2904.2 12741 80 14.55 2409 2804 6.84 / 318.53 2 44
5 13 2000.8 12952 80 14.57 1833 2137 8.98 / 320.67 2 46
6 13 1338.2 13066 80 14.63 1416 1657 10.63 / 322.32 2 46
7 13 999.0 13114 80 14.64 1197 1402 12.04 / 323.72 2 49
8 13 714.4 13146 80 14.64 996 1167 13.20 / 324.89 2 47
9 14 0.3 13225 95 14.75 480 673 13.88 / 325.56 2 109
10 14 0.5 13225 5 14.74 482 36 13.91 / 325.60 53 112
Average= 14.16
(KJ/cycle)

Cycle 21 : GMT 29/ 4/2026 10: 3: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 57.4 10 213 14.71 482 1510 1.51 / 299.23 2 24
2 6 3513.0 522 63 14.28 2746 2470 3.98 / 301.70 2 39
3 3 3148.3 642 8 14.48 2594 300 4.28 / 302.00 2 38
4 7 2854.3 12767 80 14.57 2374 2767 7.05 / 304.77 2 43
5 13 1991.3 12959 80 14.58 1828 2132 9.18 / 306.90 2 44
6 13 1259.1 13085 80 14.65 1365 1600 10.78 / 308.50 2 46
7 13 921.1 13133 80 14.66 1141 1338 12.12 / 309.84 2 48
8 13 733.0 13153 80 14.64 1000 1171 13.29 / 311.01 2 47
9 14 0.3 13234 93 14.76 461 633 13.92 / 311.64 2 105
10 14 0.4 13234 7 14.75 468 48 13.97 / 311.69 49 136
Average= 14.17
(KJ/cycle)

Cycle 20 : GMT 20/ 4/2026 5:15: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 51.6 10 212 14.71 473 1475 1.48 / 285.09 2 24
2 6 3512.1 528 63 14.29 2733 2460 3.94 / 287.55 2 39
3 3 3141.7 649 7 14.51 2577 262 4.20 / 287.82 2 38
4 7 2866.2 12773 80 14.58 2365 2759 6.96 / 290.57 2 43
5 13 2087.5 12941 80 14.57 1880 2191 9.15 / 292.77 2 45
6 13 1513.4 13037 80 14.61 1504 1758 10.90 / 294.52 2 47
7 13 992.6 13109 80 14.67 1159 1360 12.27 / 295.88 2 49
8 13 728.0 13138 80 14.66 983 1153 13.42 / 297.04 2 46
9 14 0.0 13218 95 14.77 461 647 14.06 / 297.68 2 112
10 14 0.2 13218 5 14.77 456 34 14.10 / 297.72 52 112
Average= 14.18
(KJ/cycle)

Cycle 19 : GMT 11/ 4/2026 0:40: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 71.5 12 209 14.72 499 1535 1.54 / 271.04 2 27
2 6 3447.2 494 63 14.29 2710 2440 3.97 / 273.48 2 39
3 3 3138.9 615 7 14.51 2586 263 4.24 / 273.75 2 38
4 7 2949.1 12739 80 14.56 2411 2808 7.05 / 276.55 2 43
5 13 1986.0 12955 80 14.59 1830 2136 9.18 / 278.69 2 45
6 13 1473.5 13045 80 14.62 1487 1739 10.92 / 280.43 2 47
7 13 993.4 13111 80 14.66 1161 1362 12.28 / 281.79 2 49
8 13 720.7 13144 80 14.66 980 1149 13.43 / 282.94 2 46
9 14 0.5 13224 97 14.78 459 658 14.09 / 283.60 2 101
10 14 0.6 13224 3 14.77 466 21 14.11 / 283.62 44 74
Average= 14.18
(KJ/cycle)

Cycle 18 : GMT 1/ 4/2026 20: 4: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 53.0 10 210 14.72 486 1502 1.50 / 256.95 2 26
2 6 3344.7 476 63 14.35 2651 2397 3.90 / 259.35 2 38
3 3 3049.5 597 2 14.63 2649 78 3.98 / 259.43 2 31
4 7 2962.9 12721 80 14.57 2436 2839 6.82 / 262.26 2 43
5 13 2165.3 12889 80 14.57 1935 2255 9.07 / 264.52 2 46
6 13 1545.1 12997 80 14.62 1537 1798 10.87 / 266.32 2 46
7 13 963.8 13081 80 14.70 1154 1357 12.23 / 267.68 2 48
8 13 729.6 13107 80 14.68 990 1163 13.39 / 268.84 2 47
9 14 0.0 13186 99 14.79 453 663 14.05 / 269.50 2 107
10 14 0.2 13186 1 14.78 451 7 14.06 / 269.51 48 80
Average= 14.18
(KJ/cycle)

Cycle 17 : GMT 23/ 3/2026 16: 4: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 51.3 10 208 14.72 488 1494 1.49 / 242.97 2 28
2 6 3470.0 499 63 14.34 2707 2446 3.94 / 245.41 2 39
3 3 3138.2 620 7 14.55 2571 262 4.20 / 245.67 2 39
4 7 2914.6 12743 80 14.59 2393 2793 6.99 / 248.47 2 44
5 13 1985.5 12959 80 14.62 1810 2117 9.11 / 250.58 2 45
6 13 1331.9 13073 80 14.68 1394 1637 10.75 / 252.22 2 46
7 13 991.1 13121 80 14.68 1174 1379 12.13 / 253.60 2 48
8 13 726.8 13150 80 14.68 993 1166 13.29 / 254.77 2 47
9 14 0.4 13230 97 14.79 461 661 13.96 / 255.43 2 106
10 14 0.4 13230 3 14.78 467 21 13.98 / 255.45 44 74
Average= 14.19
(KJ/cycle)

Cycle 16 : GMT 14/ 3/2026 11:20: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 53.7 10 207 14.74 469 1431 1.43 / 229.07 2 27
2 6 3337.1 465 62 14.36 2627 2339 3.77 / 231.41 2 39
3 3 3096.3 586 5 14.58 2574 188 3.96 / 231.60 2 38
4 7 2986.2 12710 80 14.58 2433 2838 6.80 / 234.44 2 43
5 13 1994.1 12944 80 14.62 1830 2140 8.94 / 236.58 2 45
6 13 1356.5 13058 80 14.68 1406 1651 10.59 / 238.23 2 47
7 13 993.1 13112 80 14.69 1173 1379 11.97 / 239.61 2 49
8 13 731.9 13141 80 14.68 997 1171 13.14 / 240.78 2 46
9 14 0.5 13222 101 14.79 465 695 13.83 / 241.47 2 104
Average= 14.20
(KJ/cycle)

Cycle 15 : GMT 5/ 3/2026 6:45: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 52.2 10 184 14.72 474 1284 1.28 / 214.26 2 27
2 6 3442.8 442 63 14.34 2676 2418 3.70 / 216.68 2 39
3 3 3422.1 563 23 14.43 2706 898 4.60 / 217.58 2 39
4 7 3110.1 12687 80 14.57 2502 2916 7.52 / 220.49 2 43
5 13 2088.4 12927 80 14.61 1865 2180 9.70 / 222.67 2 45
6 13 1485.7 13035 80 14.66 1478 1733 11.43 / 224.41 2 46
7 13 971.6 13113 80 14.72 1133 1334 12.76 / 225.74 2 48
8 13 742.6 13140 80 14.70 988 1162 13.93 / 226.90 2 45
9 14 -0.3 13225 112 14.80 447 741 14.67 / 227.64 2 110
Average= 14.23
(KJ/cycle)

Cycle 14 : GMT 24/ 2/2026 2: 7: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 50.1 9 157 14.73 483 1117 1.12 / 197.62 2 26
2 6 3356.1 386 81 14.32 2586 3000 4.12 / 200.62 2 40
3 3 3354.0 507 10 14.49 2666 386 4.50 / 201.01 2 38
4 7 3465.5 6391 80 14.53 2699 3137 7.64 / 204.15 2 44
5 13 2545.1 6607 80 14.54 2128 2475 10.12 / 206.62 2 44
6 13 1695.1 6763 80 14.64 1612 1888 12.00 / 208.51 2 44
7 13 992.3 6871 80 14.74 1163 1371 13.37 / 209.88 2 46
8 13 950.5 6877 80 14.66 1111 1303 14.68 / 211.18 2 46
9 13 724.3 6900 80 14.66 958 1124 15.80 / 212.31 2 59
10 14 1.1 6971 65 14.79 460 442 16.24 / 212.75 2 106
11 14 1.2 6971 35 14.77 440 227 16.47 / 212.98 59 247
Average= 14.20
(KJ/cycle)

Cycle 13 : GMT 19/ 2/2026 5:43: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 53.0 9 157 14.75 479 1109 1.11 / 181.29 2 25
2 6 3284.6 382 85 14.33 2548 3104 4.21 / 184.39 2 40
3 3 3285.2 503 10 14.49 2640 383 4.60 / 184.77 2 38
4 7 3394.1 2066 80 14.55 2646 3080 7.68 / 187.85 2 44
5 13 2475.0 2276 80 14.57 2097 2444 10.12 / 190.30 2 45
6 13 1625.9 2432 80 14.67 1555 1825 11.94 / 192.12 2 45
7 13 995.4 2528 80 14.75 1144 1350 13.29 / 193.47 2 47
8 13 859.3 2546 80 14.71 1052 1238 14.53 / 194.71 2 46
9 13 717.2 2561 80 14.67 958 1124 15.66 / 195.83 2 59
10 14 0.9 2632 63 14.79 462 430 16.09 / 196.27 2 114
11 14 1.1 2633 37 14.78 439 240 16.33 / 196.51 60 247
Average= 14.04
(KJ/cycle)

Cycle 12 : GMT 17/ 2/2026 9:38: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 58.1 9 157 14.76 478 1108 1.11 / 165.57 2 24
2 6 3350.2 385 82 14.33 2586 3039 4.15 / 168.61 2 41
3 3 3358.6 506 11 14.48 2641 421 4.57 / 169.03 2 39
4 3 3376.2 627 12 14.54 2662 464 5.03 / 169.49 2 40
5 7 3229.3 1231 80 14.52 2548 2960 7.99 / 172.45 2 44
6 13 2418.5 1417 80 14.55 2059 2397 10.39 / 174.85 2 44
7 13 1904.7 1501 80 14.57 1729 2015 12.40 / 176.86 2 46
8 13 974.7 1633 80 14.74 1144 1349 13.75 / 178.21 2 47
9 13 732.9 1662 80 14.72 963 1134 14.89 / 179.35 2 46
10 14 0.0 1747 127 14.81 442 831 15.72 / 180.18 2 109
Average= 13.86
(KJ/cycle)

Cycle 11 : GMT 16/ 2/2026 4:20: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 51.9 9 157 14.76 475 1101 1.10 / 150.05 2 25
2 6 3343.7 384 82 14.33 2591 3045 4.15 / 153.09 2 40
3 3 3345.9 505 11 14.49 2674 426 4.57 / 153.52 2 39
4 3 3357.0 625 11 14.54 2693 431 5.00 / 153.95 2 41
5 7 3239.9 1229 80 14.52 2542 2953 7.96 / 156.90 2 44
6 13 2339.6 1433 80 14.57 2003 2335 10.29 / 159.24 2 44
7 13 1755.4 1535 80 14.62 1633 1910 12.20 / 161.15 2 45
8 13 994.7 1643 80 14.73 1146 1350 13.55 / 162.50 2 47
9 13 725.8 1675 80 14.72 971 1143 14.69 / 163.64 2 45
10 14 0.3 1758 127 14.82 436 821 15.51 / 164.46 2 105
Average= 13.71
(KJ/cycle)

Cycle 10 : GMT 14/ 2/2026 22:53: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 57.6 9 157 14.77 469 1088 1.09 / 134.49 2 23
2 6 3336.5 379 83 14.34 2586 3078 4.17 / 137.57 2 40
3 3 3327.3 500 10 14.51 2633 382 4.55 / 137.95 2 38
4 3 3308.9 621 9 14.56 2629 345 4.89 / 138.29 2 39
5 7 3275.9 1224 80 14.51 2575 2989 7.88 / 141.28 2 43
6 13 2466.1 1398 80 14.54 2095 2437 10.32 / 143.72 2 44
7 13 1772.3 1524 80 14.62 1642 1920 12.24 / 145.64 2 45
8 13 980.6 1638 80 14.75 1121 1323 13.56 / 146.96 2 46
9 13 738.5 1668 80 14.73 974 1148 14.71 / 148.11 2 45
10 14 0.0 1754 129 14.82 437 835 15.54 / 148.95 2 104
Average= 13.54
(KJ/cycle)

Cycle 9 : GMT 13/ 2/2026 17:29: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 50.6 9 157 14.76 482 1117 1.12 / 119.08 2 26
2 6 3377.6 395 80 14.34 2628 3015 4.13 / 122.09 2 41
3 3 3372.5 516 10 14.50 2714 394 4.53 / 122.49 2 39
4 3 3341.8 636 8 14.56 2685 313 4.84 / 122.80 2 40
5 7 3312.8 1240 80 14.51 2607 3026 7.86 / 125.83 2 44
6 13 2372.0 1468 80 14.57 2041 2379 10.24 / 128.20 2 44
7 13 1652.6 1600 80 14.65 1584 1856 12.10 / 130.06 2 45
8 13 983.5 1702 80 14.75 1135 1339 13.44 / 131.40 2 47
9 13 740.0 1732 80 14.73 971 1144 14.58 / 132.54 2 44
10 14 0.5 1818 133 14.82 435 857 15.44 / 133.40 2 106
Average= 13.34
(KJ/cycle)

Cycle 8 : GMT 12/ 2/2026 10:59: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 51.3 9 157 14.76 485 1124 1.12 / 103.59 2 25
2 6 3350.0 393 82 14.33 2627 3087 4.21 / 106.68 2 41
3 3 3350.7 514 10 14.50 2668 387 4.60 / 107.07 2 39
4 3 3342.3 634 10 14.56 2708 394 4.99 / 107.46 2 39
5 7 3248.3 1238 80 14.51 2600 3018 8.01 / 110.48 2 44
6 13 2271.8 1460 80 14.59 1994 2327 10.34 / 112.80 2 45
7 13 1534.0 1592 80 14.67 1507 1769 12.11 / 114.57 2 45
8 13 978.3 1676 80 14.73 1159 1366 13.47 / 115.94 2 47
9 13 732.8 1705 80 14.72 990 1166 14.64 / 117.11 2 46
10 14 0.1 1787 127 14.81 455 856 15.49 / 117.96 2 100
Average= 13.11
(KJ/cycle)

Cycle 7 : GMT 11/ 2/2026 5: 2: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 51.7 9 157 14.76 500 1159 1.16 / 87.97 2 26
2 6 3316.1 388 84 14.33 2642 3180 4.34 / 91.15 2 41
3 3 3315.6 509 10 14.50 2695 391 4.73 / 91.54 2 38
4 3 3315.8 629 10 14.56 2723 396 5.13 / 91.94 2 40
5 7 3215.7 1233 80 14.52 2574 2990 8.12 / 94.93 2 44
6 13 2284.1 1449 80 14.58 2004 2337 10.45 / 97.26 2 43
7 13 1608.4 1569 80 14.65 1562 1831 12.28 / 99.09 2 45
8 13 978.8 1665 80 14.74 1149 1355 13.64 / 100.45 2 46
9 13 738.6 1694 80 14.72 990 1166 14.80 / 101.61 2 46
10 14 0.4 1781 127 14.82 453 853 15.66 / 102.47 2 104
Average= 12.81
(KJ/cycle)

Cycle 6 : GMT 9/ 2/2026 23: 8: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 52.5 9 157 14.76 492 1140 1.14 / 72.11 2 27
2 6 3377.6 396 80 14.36 2681 3080 4.22 / 75.19 2 41
3 3 3377.6 517 10 14.53 2710 394 4.61 / 75.58 2 38
4 3 3377.1 638 10 14.57 2785 406 5.02 / 75.99 2 39
5 7 3283.3 1241 80 14.51 2650 3076 8.10 / 79.06 2 44
6 13 2356.8 1451 80 14.58 2057 2399 10.49 / 81.46 2 44
7 13 1673.2 1571 80 14.65 1606 1882 12.38 / 83.35 2 46
8 13 985.6 1673 80 14.75 1169 1379 13.76 / 84.72 2 45
9 13 725.9 1706 80 14.74 999 1178 14.93 / 85.90 2 44
10 14 0.3 1789 133 14.83 460 907 15.84 / 86.81 2 112
Average= 12.40
(KJ/cycle)

Cycle 5 : GMT 8/ 2/2026 17: 7: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 50.2 9 157 14.75 506 1172 1.17 / 55.97 2 27
2 6 3283.2 384 85 14.36 2647 3231 4.40 / 59.20 2 40
3 3 3282.5 505 10 14.51 2711 393 4.80 / 59.60 2 39
4 3 3282.6 626 10 14.55 2754 401 5.20 / 60.00 2 40
5 7 3204.3 1229 80 14.52 2600 3020 8.22 / 63.02 2 44
6 13 2329.8 1427 80 14.58 2072 2417 10.63 / 65.43 2 44
7 13 1793.4 1517 80 14.61 1724 2015 12.65 / 67.45 2 45
8 13 971.2 1637 80 14.75 1194 1409 14.06 / 68.86 2 47
9 13 737.1 1666 80 14.73 1030 1214 15.27 / 70.07 2 45
10 14 0.0 1754 131 14.82 462 897 16.17 / 70.97 2 115
Average= 11.83
(KJ/cycle)

Cycle 4 : GMT 7/ 2/2026 11:43: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 74.2 11 157 14.74 540 1250 1.25 / 39.70 2 26
2 6 3321.7 389 83 14.35 2696 3211 4.46 / 42.92 2 41
3 3 3320.5 510 10 14.50 2807 407 4.87 / 43.32 2 38
4 3 3318.2 631 10 14.56 2798 407 5.28 / 43.73 2 39
5 7 3252.9 1234 80 14.51 2677 3107 8.38 / 46.84 2 44
6 13 2360.3 1432 80 14.56 2116 2465 10.85 / 49.30 2 44
7 13 1571.4 1576 80 14.66 1615 1894 12.74 / 51.20 2 45
8 13 965.3 1666 80 14.74 1210 1427 14.17 / 52.62 2 46
9 13 733.1 1694 80 14.72 1052 1239 15.41 / 53.86 2 45
10 14 0.4 1780 133 14.81 476 938 16.34 / 54.80 2 114
Average= 10.96
(KJ/cycle)

Cycle 3 : GMT 6/ 2/2026 5:52: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 72.8 11 157 14.85 555 1294 1.29 / 23.21 2 28
2 6 3401.2 405 80 14.40 2728 3143 4.44 / 26.36 2 41
3 3 3401.1 526 10 14.54 2814 409 4.85 / 26.76 2 39
4 3 3401.2 647 10 14.59 2839 414 5.26 / 27.18 2 39
5 7 3285.5 1249 80 14.52 2685 3119 8.38 / 30.30 2 44
6 13 2433.6 1442 80 14.56 2165 2522 10.90 / 32.82 2 43
7 13 1538.4 1604 80 14.68 1600 1879 12.78 / 34.70 2 45
8 13 993.5 1688 80 14.74 1248 1472 14.25 / 36.17 2 46
9 13 735.7 1720 80 14.72 1062 1251 15.50 / 37.42 2 46
10 14 0.9 1806 140 14.81 499 1035 16.54 / 38.46 2 115
Average= 9.61
(KJ/cycle)

Cycle 2 : GMT 4/ 2/2026 23:35: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 50.0 12 336 14.83 522 2601 2.60 / 17.12 2 25
2 6 1019.0 187 60 14.72 1211 1070 3.67 / 18.19 2 33
3 3 768.5 308 8 14.90 1130 135 3.81 / 18.33 2 33
4 7 550.2 1031 80 15.08 923 1114 4.92 / 19.44 2 36
5 13 520.5 1037 80 15.00 883 1060 5.98 / 20.50 2 38
6 14 0.5 1111 189 14.94 502 1417 7.40 / 21.92 2 109
Average= 7.31
(KJ/cycle)

Cycle 1 : GMT 4/ 2/2026 4:55: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 51.0 11 284 14.65 496 2064 2.06 / 8.63 2 26
2 6 1014.1 139 60 14.67 1186 1044 3.11 / 9.67 2 29
3 3 1404.9 260 41 14.77 1490 902 4.01 / 10.57 2 36
4 3 1080.4 381 24 14.86 1329 474 4.48 / 11.05 2 38
5 3 782.0 502 9 14.96 1180 159 4.64 / 11.21 2 36
6 7 425.7 985 80 15.10 832 1005 5.65 / 12.21 2 33
7 13 394.3 991 80 15.03 788 947 6.60 / 13.16 2 33
8 14 -0.1 1046 185 14.96 493 1364 7.96 / 14.52 2 113
Average= 7.26
(KJ/cycle)

Cycle 0 : GMT 3/ 2/2026 11:18: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 13 144.7 26810 407 15.05 581 3559 3.56 / 3.56 2 22
2 7 218.8 26812 80 14.89 587 699 4.26 / 4.26 2 24
3 13 209.6 26818 80 14.84 582 691 4.95 / 4.95 2 27
4 13 89.3 26836 80 14.79 508 601 5.55 / 5.55 2 25
5 14 0.0 26851 155 14.75 443 1013 6.56 / 6.56 2 102
Average= 6.56
(KJ/cycle)