SIO Argo Site:
Pump Diagnostics







Serial= 6124 - WMO= 7901076


Cycle 57 : GMT 2/10/2026 1:22:59

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 56.1 7 93 14.92 391 543 0.54 / 835.46 2 23
2 6 3683.5 395 121 14.49 2592 4545 5.09 / 840.01 2 35
3 6 3529.8 455 89 14.40 2499 3203 8.29 / 843.21 2 37
4 6 2392.9 695 75 14.61 1821 1995 10.29 / 845.20 2 41
5 6 1489.8 876 1 14.84 1336 20 10.30 / 845.22 2 28
6 7 927.0 14077 80 15.20 943 1147 11.45 / 846.37 2 40
7 13 852.0 14094 90 15.10 892 1212 12.66 / 847.58 3 43
8 13 574.7 14130 90 15.01 709 958 13.62 / 848.54 3 47
9 14 0.0 14201 180 14.97 362 975 14.60 / 849.52 3 123
Average= 14.65
(KJ/cycle)

Cycle 56 : GMT 22/ 9/2026 4:23:59

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 54.6 7 91 14.92 392 532 0.53 / 819.26 2 20
2 6 4488.9 551 122 14.38 3065 5377 5.91 / 824.64 2 36
3 6 3963.7 671 88 14.36 2753 3479 9.39 / 828.12 2 37
4 6 2755.1 911 81 14.54 2047 2411 11.80 / 830.53 2 40
5 6 1338.8 1212 1 14.89 1229 18 11.82 / 830.55 2 27
6 7 1002.3 14234 80 15.21 976 1188 13.00 / 831.73 2 40
7 13 913.8 14250 90 15.11 921 1252 14.26 / 832.99 3 44
8 13 584.5 14294 90 15.02 715 967 15.22 / 833.95 2 46
9 14 0.0 14366 180 14.97 359 967 16.19 / 834.92 5 111
Average= 14.65
(KJ/cycle)

Cycle 55 : GMT 12/ 9/2026 4:43:59

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 63.3 7 90 14.93 395 531 0.53 / 803.51 3 20
2 6 4134.8 480 121 14.43 2866 5004 5.53 / 808.51 2 36
3 6 3912.2 540 89 14.34 2725 3478 9.01 / 811.99 2 37
4 6 2701.8 780 79 14.55 2006 2306 11.32 / 814.30 2 40
5 3 1021.6 1562 1 15.01 1017 15 11.33 / 814.31 2 27
6 7 1016.7 14163 80 15.20 992 1206 12.54 / 815.52 2 39
7 13 930.1 14179 90 15.11 928 1262 13.80 / 816.78 3 42
8 13 549.9 14229 90 15.02 693 937 14.74 / 817.72 2 44
9 14 0.3 14296 183 14.97 369 1011 15.75 / 818.73 3 113
Average= 14.62
(KJ/cycle)

Cycle 54 : GMT 2/ 9/2026 6: 9: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 65.1 7 91 14.90 401 544 0.54 / 788.48 2 19
2 6 4053.3 461 121 14.44 2809 4908 5.45 / 793.39 2 36
3 6 3827.0 521 89 14.35 2665 3404 8.86 / 796.79 2 36
4 6 2371.7 822 78 14.62 1807 2061 10.92 / 798.85 2 40
5 7 957.3 14144 80 15.21 943 1147 12.06 / 800.00 2 38
6 13 858.3 14161 90 15.12 882 1200 13.26 / 801.20 3 41
7 13 432.4 14214 90 15.02 612 827 14.09 / 802.03 2 42
8 14 -0.3 14270 178 14.98 357 952 15.04 / 802.98 3 109
Average= 14.60
(KJ/cycle)

Cycle 53 : GMT 23/ 8/2026 8: 0: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 63.3 7 93 14.92 392 544 0.54 / 777.12 2 18
2 6 2146.0 206 275 14.55 1658 6634 7.18 / 783.76 2 31
3 7 965.9 13889 80 15.19 967 1175 8.35 / 784.93 2 38
4 13 880.5 13905 90 15.09 907 1232 9.58 / 786.17 3 42
5 13 363.9 13975 90 14.99 578 780 10.36 / 786.95 2 42
6 14 0.1 14025 178 14.95 372 990 11.35 / 787.94 3 115
Average= 14.59
(KJ/cycle)

Cycle 52 : GMT 13/ 8/2026 14: 2: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 59.3 7 94 14.92 400 561 0.56 / 764.27 3 18
2 6 2966.9 299 120 14.61 2146 3762 4.32 / 768.03 2 31
3 6 2961.2 359 90 14.52 2150 2810 7.13 / 770.84 2 35
4 6 2413.9 480 71 14.60 1824 1891 9.02 / 772.73 2 39
5 7 954.1 13982 80 15.20 948 1153 10.18 / 773.88 2 37
6 13 876.9 13999 90 15.11 897 1220 11.40 / 775.10 3 39
7 14 0.0 14125 268 14.97 368 1476 12.87 / 776.58 2 115
Average= 14.65
(KJ/cycle)

Cycle 51 : GMT 3/ 8/2026 18:24: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 69.2 7 93 14.93 414 575 0.57 / 749.57 3 18
2 6 3735.1 404 121 14.50 2615 4588 5.16 / 754.16 2 35
3 6 3586.6 464 89 14.41 2517 3228 8.39 / 757.39 2 36
4 6 2470.4 705 76 14.60 1872 2077 10.47 / 759.47 2 39
5 6 1561.8 885 1 14.84 1378 20 10.49 / 759.49 2 27
6 7 995.6 14087 80 15.21 964 1173 11.66 / 760.66 2 36
7 13 920.5 14103 90 15.11 915 1244 12.91 / 761.90 3 38
8 13 392.2 14172 90 15.01 585 790 13.70 / 762.69 2 40
9 14 0.1 14226 183 14.97 370 1014 14.71 / 763.71 3 124
Average= 14.69
(KJ/cycle)

Cycle 50 : GMT 24/ 7/2026 21: 3: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 68.5 7 96 14.93 398 570 0.57 / 735.55 3 18
2 6 3510.3 382 121 14.54 2474 4353 4.92 / 739.90 2 35
3 6 3393.1 442 89 14.45 2405 3093 8.02 / 743.00 2 35
4 6 2313.3 682 75 14.64 1768 1941 9.96 / 744.94 2 39
5 7 910.3 14064 80 15.22 924 1125 11.08 / 746.06 2 37
6 13 831.4 14081 90 15.12 866 1178 12.26 / 747.24 3 40
7 13 402.3 14135 90 15.03 592 801 13.06 / 748.04 2 42
8 14 -0.1 14192 176 14.98 363 957 14.02 / 749.00 3 106
Average= 14.69
(KJ/cycle)

Cycle 49 : GMT 15/ 7/2026 0:16: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 67.5 7 97 14.94 406 588 0.59 / 719.84 3 16
2 6 4646.3 584 122 14.37 3159 5538 6.13 / 725.38 2 35
3 6 3877.2 764 87 14.41 2696 3380 9.51 / 728.76 2 37
4 6 2477.7 1064 81 14.61 1874 2218 11.72 / 730.98 2 40
5 6 1326.9 1305 1 14.88 1231 18 11.74 / 730.99 2 28
6 7 962.1 14266 80 15.22 951 1158 12.90 / 732.15 2 38
7 13 881.6 14283 90 15.12 896 1219 14.12 / 733.37 3 40
8 13 137.4 14380 90 15.01 472 638 14.76 / 734.01 2 38
9 14 -0.1 14404 178 14.98 364 971 15.73 / 734.98 4 135
Average= 14.70
(KJ/cycle)

Cycle 48 : GMT 4/ 7/2026 23:58: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 69.5 7 97 14.94 381 552 0.55 / 703.50 3 15
2 6 4820.7 627 122 14.36 3278 5743 6.29 / 709.24 2 35
3 6 4025.3 807 87 14.39 2792 3495 9.79 / 712.74 2 37
4 6 2749.0 1047 83 14.55 2042 2466 12.26 / 715.20 2 40
5 6 1502.9 1288 1 14.85 1359 20 12.28 / 715.22 2 28
6 7 952.3 14309 80 15.22 950 1157 13.43 / 716.38 2 39
7 13 867.5 14326 90 15.12 890 1211 14.64 / 717.59 3 42
8 13 267.4 14406 90 15.02 512 692 15.34 / 718.28 2 41
9 14 0.2 14445 178 14.98 364 971 16.31 / 719.25 3 126
Average= 14.68
(KJ/cycle)

Cycle 47 : GMT 24/ 6/2026 23: 1: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 72.1 7 98 14.94 405 593 0.59 / 687.61 3 14
2 6 4754.1 613 122 14.37 3221 5647 6.24 / 693.26 2 36
3 6 3955.5 794 87 14.41 2738 3433 9.67 / 696.69 2 38
4 6 2483.5 1094 82 14.61 1871 2241 11.91 / 698.93 2 41
5 7 959.5 14296 80 15.22 953 1160 13.07 / 700.09 2 38
6 13 880.4 14313 90 15.12 898 1222 14.30 / 701.32 3 40
7 13 236.0 14397 90 15.02 489 661 14.96 / 701.98 2 37
8 14 0.2 14434 180 14.98 359 968 15.93 / 702.94 3 124
Average= 14.64
(KJ/cycle)

Cycle 46 : GMT 14/ 6/2026 22:16: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 60.3 7 96 14.94 396 568 0.57 / 670.98 3 15
2 6 4753.4 600 122 14.37 3222 5649 6.22 / 676.63 2 36
3 6 3977.5 780 87 14.41 2757 3456 9.67 / 680.09 2 39
4 6 2997.6 960 84 14.50 2179 2654 12.33 / 682.74 2 40
5 3 1023.9 1682 1 15.01 1012 15 12.34 / 682.76 2 26
6 7 993.6 14283 80 15.21 972 1183 13.52 / 683.94 2 38
7 13 915.2 14299 90 15.12 922 1255 14.78 / 685.20 3 41
8 13 434.8 14361 90 15.02 623 842 15.62 / 686.04 2 41
9 14 0.5 14418 180 14.98 364 981 16.60 / 687.02 3 108
Average= 14.62
(KJ/cycle)

Cycle 45 : GMT 4/ 6/2026 21:39: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 62.8 7 97 14.94 386 559 0.56 / 655.13 3 17
2 6 4783.5 609 122 14.37 3241 5682 6.24 / 660.81 2 36
3 6 3761.7 850 86 14.44 2639 3277 9.52 / 664.09 2 39
4 6 2594.6 1090 83 14.58 1947 2356 11.87 / 666.44 2 40
5 7 962.1 14292 80 15.22 954 1162 13.04 / 667.61 2 38
6 13 880.1 14309 90 15.12 896 1219 14.26 / 668.82 3 41
7 13 166.1 14403 90 15.03 455 615 14.87 / 669.44 2 38
8 14 0.3 14431 178 14.98 366 976 15.85 / 670.42 3 131
Average= 14.57
(KJ/cycle)

Cycle 44 : GMT 25/ 5/2026 20:57: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 66.3 7 98 14.93 405 593 0.59 / 638.91 3 16
2 6 4975.1 673 122 14.35 3358 5879 6.47 / 644.79 2 37
3 6 4101.7 853 87 14.39 2839 3554 10.03 / 648.35 2 39
4 6 2619.9 1154 83 14.59 1955 2367 12.39 / 650.71 2 40
5 6 1428.8 1394 1 14.87 1285 19 12.41 / 650.73 2 29
6 7 950.7 14355 80 15.23 944 1150 13.56 / 651.88 2 38
7 13 864.3 14372 90 15.13 887 1208 14.77 / 653.09 3 40
8 13 70.4 14476 90 15.03 414 560 15.33 / 653.65 3 34
9 14 0.1 14495 172 14.99 356 918 16.25 / 654.57 3 131
Average= 14.55
(KJ/cycle)

Cycle 43 : GMT 15/ 5/2026 19: 5: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 65.4 7 97 14.94 404 585 0.59 / 622.47 3 16
2 6 4883.1 645 122 14.36 3292 5767 6.35 / 628.23 2 36
3 6 3817.1 886 86 14.44 2668 3313 9.67 / 631.55 2 38
4 6 2907.4 1066 84 14.52 2131 2599 12.27 / 634.15 2 40
5 3 1027.4 1727 1 15.00 1023 15 12.28 / 634.16 2 26
6 7 986.5 14328 80 15.22 968 1179 13.46 / 635.34 2 38
7 13 899.8 14345 90 15.12 915 1245 14.70 / 636.59 3 41
8 13 372.8 14416 90 15.02 574 776 15.48 / 637.36 2 40
9 14 0.2 14466 174 14.99 368 960 16.44 / 638.32 3 111
Average= 14.51
(KJ/cycle)

Cycle 42 : GMT 5/ 5/2026 17:48: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 63.0 7 97 14.94 408 591 0.59 / 606.32 3 18
2 6 4810.0 620 122 14.37 3249 5696 6.29 / 612.02 2 36
3 6 4033.3 800 87 14.40 2795 3502 9.79 / 615.52 2 38
4 6 2540.0 1101 82 14.60 1911 2288 12.08 / 617.81 2 41
5 6 1403.3 1341 1 14.87 1278 19 12.10 / 617.83 2 29
6 7 954.0 14302 80 15.23 950 1157 13.25 / 618.99 2 38
7 13 874.8 14319 90 15.13 901 1227 14.48 / 620.21 3 42
8 13 312.3 14392 90 15.03 544 736 15.22 / 620.95 2 40
9 14 0.2 14434 172 14.99 362 933 16.15 / 621.88 3 140
Average= 14.46
(KJ/cycle)

Cycle 41 : GMT 25/ 4/2026 17: 4: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 63.5 7 98 14.94 391 572 0.57 / 590.07 3 17
2 6 4542.0 551 122 14.41 3097 5445 6.02 / 595.51 2 36
3 6 4021.1 671 88 14.39 2786 3528 9.55 / 599.04 2 38
4 6 2708.0 911 80 14.57 2006 2338 11.88 / 601.38 2 41
5 6 1262.3 1212 1 14.90 1200 18 11.90 / 601.40 2 29
6 7 949.7 14233 80 15.23 948 1155 13.06 / 602.55 2 39
7 13 879.1 14250 90 15.13 894 1217 14.27 / 603.77 3 40
8 13 651.4 14278 90 15.04 751 1017 15.29 / 604.79 2 43
9 14 0.0 14356 172 14.99 367 946 16.24 / 605.73 3 108
Average= 14.42
(KJ/cycle)

Cycle 40 : GMT 15/ 4/2026 17:39: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 69.7 7 96 14.95 404 580 0.58 / 573.65 3 15
2 6 4918.4 648 122 14.36 3322 5820 6.40 / 579.47 2 35
3 6 3878.6 889 86 14.44 2700 3353 9.75 / 582.83 2 39
4 6 2697.9 1129 83 14.57 2004 2423 12.18 / 585.25 2 41
5 6 1497.5 1370 1 14.87 1344 20 12.20 / 585.27 2 28
6 6 1299.4 1430 1 14.90 1222 18 12.21 / 585.29 2 28
7 7 993.3 14331 80 15.22 970 1181 13.40 / 586.47 2 39
8 13 918.3 14348 90 15.13 925 1260 14.65 / 587.73 3 40
9 13 387.0 14414 90 15.03 590 798 15.45 / 588.53 2 40
10 14 -0.1 14464 176 14.99 367 968 16.42 / 589.50 2 140
Average= 14.38
(KJ/cycle)

Cycle 39 : GMT 5/ 4/2026 16:25: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 61.5 7 96 14.95 404 580 0.58 / 557.45 3 15
2 6 4859.8 638 122 14.38 3286 5765 6.34 / 563.21 2 36
3 6 4040.7 818 87 14.41 2808 3520 9.86 / 566.73 2 38
4 6 2583.3 1119 83 14.60 1934 2344 12.21 / 569.08 2 40
5 6 1415.8 1359 1 14.87 1307 19 12.23 / 569.10 2 29
6 7 967.4 14320 80 15.23 965 1176 13.40 / 570.27 2 38
7 13 878.2 14337 90 15.13 904 1231 14.63 / 571.50 3 40
8 13 167.0 14430 90 15.03 471 637 15.27 / 572.14 2 37
9 14 0.4 14458 172 14.99 362 933 16.21 / 573.07 3 112
Average= 14.33
(KJ/cycle)

Cycle 38 : GMT 26/ 3/2026 15:13: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 65.5 7 97 14.95 395 573 0.57 / 541.36 3 16
2 6 4778.6 608 122 14.39 3232 5674 6.25 / 547.04 2 37
3 6 3937.6 788 87 14.42 2736 3432 9.68 / 550.47 2 38
4 6 2504.6 1089 82 14.62 1894 2271 11.95 / 552.74 2 42
5 6 1369.3 1329 1 14.89 1277 19 11.97 / 552.76 2 29
6 7 947.2 14291 80 15.23 949 1156 13.13 / 553.91 2 38
7 13 871.8 14307 90 15.14 894 1218 14.34 / 555.13 3 40
8 13 390.3 14369 90 15.04 589 797 15.14 / 555.93 2 40
9 14 0.4 14418 172 15.00 364 939 16.08 / 556.87 3 138
Average= 14.28
(KJ/cycle)

Cycle 37 : GMT 16/ 3/2026 14:46: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 59.2 7 95 14.96 398 566 0.57 / 525.25 3 15
2 6 4525.7 539 122 14.42 3102 5457 6.02 / 530.71 2 36
3 6 4015.8 660 88 14.40 2796 3543 9.57 / 534.25 2 39
4 6 2779.7 900 81 14.57 2055 2425 11.99 / 536.68 2 41
5 3 1034.6 1742 1 15.03 1024 15 12.01 / 536.69 2 27
6 7 1010.7 14342 80 15.23 985 1200 13.21 / 537.89 2 40
7 13 916.8 14359 90 15.14 917 1250 14.46 / 539.14 3 42
8 13 265.1 14448 90 15.04 514 696 15.15 / 539.84 2 40
9 14 0.0 14485 174 15.00 365 953 16.10 / 540.79 3 106
Average= 14.23
(KJ/cycle)

Cycle 36 : GMT 6/ 3/2026 13:11: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 69.0 7 96 14.97 388 558 0.56 / 509.27 3 16
2 6 4625.2 578 122 14.42 3162 5563 6.12 / 514.83 2 37
3 6 4094.9 699 88 14.40 2835 3593 9.71 / 518.43 2 39
4 6 2549.5 999 81 14.62 1922 2276 11.99 / 520.70 2 41
5 7 968.5 14381 80 15.23 961 1171 13.16 / 521.87 2 40
6 13 888.1 14398 90 15.13 905 1232 14.39 / 523.11 3 42
7 13 164.7 14491 90 15.04 463 627 15.02 / 523.73 2 38
8 14 0.6 14517 172 15.00 369 952 15.97 / 524.68 3 116
Average= 14.18
(KJ/cycle)

Cycle 35 : GMT 24/ 2/2026 10:58: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 67.8 7 95 15.02 393 561 0.56 / 493.27 3 16
2 6 4784.0 604 132 14.39 3250 6173 6.73 / 499.44 2 38
3 6 3946.9 784 97 14.43 2753 3853 10.59 / 503.29 2 40
4 6 2193.8 1145 63 14.72 1709 1585 12.17 / 504.88 2 42
5 6 1404.8 1325 1 14.91 1275 19 12.19 / 504.90 2 28
6 7 967.2 14407 80 15.23 956 1165 13.36 / 506.06 2 40
7 13 883.9 14423 100 15.13 900 1362 14.72 / 507.42 3 42
8 13 39.2 14534 100 15.04 386 581 15.30 / 508.01 2 30
9 14 0.1 14545 133 15.01 355 709 16.01 / 508.71 2 111
Average= 14.13
(KJ/cycle)

Cycle 34 : GMT 14/ 2/2026 8:24: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 67.2 7 95 15.02 389 555 0.56 / 477.01 3 15
2 6 4781.0 610 132 14.40 3251 6180 6.73 / 483.19 2 38
3 6 3948.9 791 97 14.43 2749 3848 10.58 / 487.04 2 40
4 6 2361.1 1091 63 14.68 1814 1678 12.26 / 488.72 2 41
5 6 1283.4 1331 1 14.92 1191 18 12.28 / 488.74 2 28
6 7 988.6 7213 80 15.26 974 1189 13.47 / 489.92 2 41
7 13 908.0 7230 100 15.16 920 1395 14.86 / 491.32 3 41
8 13 175.5 7320 100 15.08 458 691 15.55 / 492.01 2 33
9 14 0.7 7346 129 15.05 359 697 16.25 / 492.71 2 102
Average= 14.08
(KJ/cycle)

Cycle 33 : GMT 9/ 2/2026 5:46: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 69.2 7 95 15.05 390 558 0.56 / 460.65 3 16
2 6 4833.4 629 132 14.40 3277 6229 6.79 / 466.88 2 37
3 6 3994.7 810 96 14.44 2772 3843 10.63 / 470.72 2 40
4 6 2431.8 1110 65 14.68 1848 1763 12.39 / 472.48 2 42
5 7 978.3 7232 80 15.27 966 1180 13.57 / 473.66 2 40
6 13 902.8 7249 100 15.16 919 1393 14.97 / 475.06 3 41
7 13 169.0 7342 100 15.08 456 688 15.65 / 475.74 2 33
8 14 0.3 7368 131 15.06 362 714 16.37 / 476.46 2 110
Average= 14.01
(KJ/cycle)

Cycle 32 : GMT 4/ 2/2026 2:49: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 68.0 7 95 15.06 389 557 0.56 / 445.78 3 16
2 6 4707.0 600 112 14.45 3219 5210 5.77 / 450.99 2 37
3 6 3644.9 960 77 14.55 2581 2892 8.66 / 453.88 2 40
4 6 2471.6 1320 74 14.70 1884 2049 10.71 / 455.93 2 41
5 6 1374.7 1681 26 14.90 1215 471 11.18 / 456.40 2 40
6 3 1064.7 1801 3 14.98 1056 47 11.23 / 456.45 2 28
7 7 887.1 5282 80 15.29 907 1109 12.33 / 457.56 2 39
8 13 815.3 5299 80 15.20 865 1052 13.39 / 458.61 3 39
9 13 222.8 5375 80 15.12 488 590 13.98 / 459.20 2 34
10 14 0.3 5408 165 15.09 357 889 14.87 / 460.09 3 109
Average= 13.94
(KJ/cycle)

Cycle 31 : GMT 31/ 1/2026 8:30: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 67.3 7 101 14.93 388 585 0.59 / 430.98 3 17
2 6 4592.0 578 112 14.45 3157 5109 5.69 / 436.09 2 38
3 6 3531.2 938 77 14.56 2521 2826 8.52 / 438.92 2 41
4 6 2345.1 1298 74 14.71 1805 1965 10.49 / 440.88 2 41
5 6 1434.1 1539 24 14.88 1252 447 10.93 / 441.33 2 41
6 7 838.2 5259 80 15.30 872 1067 12.00 / 442.40 2 38
7 13 762.1 5276 80 15.22 831 1012 13.01 / 443.41 3 39
8 13 680.4 5288 80 15.15 776 941 13.95 / 444.35 2 39
9 14 0.2 5369 165 15.11 351 875 14.83 / 445.22 2 106
Average= 13.91
(KJ/cycle)

Cycle 30 : GMT 27/ 1/2026 14:50: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 66.0 7 102 14.93 390 594 0.59 / 414.85 3 18
2 6 4576.8 579 112 14.45 3134 5072 5.67 / 419.93 2 38
3 3 4066.0 699 93 14.41 2825 3786 9.45 / 423.71 2 40
4 7 2088.7 1301 80 14.94 1646 1967 11.42 / 425.68 2 43
5 13 1809.1 1353 80 14.89 1482 1765 13.18 / 427.45 2 46
6 13 999.0 1477 80 14.96 982 1175 14.36 / 428.62 2 44
7 13 514.6 1542 80 14.94 677 809 15.17 / 429.43 2 40
8 14 0.4 1608 183 14.97 353 967 16.14 / 430.40 3 110
Average= 13.88
(KJ/cycle)

Cycle 29 : GMT 26/ 1/2026 11:52: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 63.3 7 102 15.07 389 598 0.60 / 398.37 3 18
2 6 4567.4 583 112 14.48 3139 5091 5.69 / 403.46 2 37
3 3 4070.4 703 93 14.44 2835 3807 9.50 / 407.27 2 39
4 7 2080.2 1306 80 14.95 1646 1969 11.46 / 409.23 2 42
5 13 1870.4 1349 80 14.89 1512 1801 13.27 / 411.04 2 46
6 13 990.4 1481 80 14.97 971 1163 14.43 / 412.20 2 44
7 13 909.5 1494 80 14.91 925 1103 15.53 / 413.30 2 45
8 14 0.6 1598 180 14.97 356 959 16.49 / 414.26 2 109
Average= 13.81
(KJ/cycle)

Cycle 28 : GMT 25/ 1/2026 9: 4: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 63.9 7 103 15.06 391 607 0.61 / 383.87 3 17
2 6 4504.5 559 112 14.49 3095 5023 5.63 / 388.90 2 38
3 6 3666.9 799 77 14.55 2592 2904 8.53 / 391.80 2 41
4 6 2344.8 1159 74 14.72 1811 1973 10.51 / 393.77 2 42
5 3 1400.2 1400 20 14.89 1241 370 10.88 / 394.14 2 40
6 7 863.9 4881 80 15.31 890 1090 11.97 / 395.23 2 39
7 13 777.4 4898 80 15.23 837 1020 12.99 / 396.25 3 39
8 13 273.7 4963 80 15.14 521 631 13.62 / 396.88 2 35
9 14 0.2 5002 165 15.11 355 885 14.50 / 397.77 3 115
Average= 13.72
(KJ/cycle)

Cycle 27 : GMT 21/ 1/2026 21:33: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 61.1 7 93 15.00 387 540 0.54 / 368.64 3 17
2 6 4493.6 541 112 14.48 3073 4984 5.52 / 373.63 2 38
3 6 3774.0 782 78 14.53 2653 3007 8.53 / 376.63 2 40
4 6 2518.9 1142 75 14.69 1906 2100 10.63 / 378.73 2 42
5 3 1543.2 1382 28 14.86 1321 550 11.18 / 379.28 2 41
6 7 917.7 4863 80 15.30 928 1136 12.32 / 380.42 2 40
7 13 836.0 4880 80 15.22 878 1069 13.38 / 381.49 3 40
8 13 556.5 4917 80 15.14 698 845 14.23 / 382.33 2 38
9 14 -0.1 4986 172 15.11 360 936 15.17 / 383.27 2 113
Average= 13.69
(KJ/cycle)

Cycle 26 : GMT 18/ 1/2026 10:15: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 66.6 7 90 15.03 394 533 0.53 / 352.60 2 17
2 6 4532.7 537 112 14.49 3097 5026 5.56 / 357.62 2 37
3 6 3804.3 777 78 14.53 2674 3031 8.59 / 360.65 2 40
4 6 2526.4 1137 33 14.75 1917 933 9.52 / 361.59 2 40
5 7 1978.0 4858 80 15.13 1583 1916 11.44 / 363.50 2 44
6 13 1868.3 4881 80 15.03 1518 1825 13.26 / 365.33 2 47
7 13 944.9 5016 80 15.04 952 1145 14.41 / 366.47 2 44
8 13 369.1 5091 80 15.03 584 702 15.11 / 367.17 2 38
9 14 0.2 5140 172 15.03 359 928 16.04 / 368.10 2 109
Average= 13.63
(KJ/cycle)

Cycle 25 : GMT 14/ 1/2026 20:25: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 63.9 7 92 15.00 394 544 0.54 / 336.55 3 17
2 6 4580.7 550 112 14.49 3139 5094 5.64 / 341.64 2 38
3 6 3756.3 790 77 14.55 2646 2964 8.60 / 344.61 2 41
4 6 2505.1 1151 34 14.76 1896 951 9.55 / 345.56 2 40
5 6 2146.9 1271 1 14.88 1780 26 9.58 / 345.58 2 27
6 7 1896.0 4872 80 15.15 1535 1860 11.44 / 347.44 2 44
7 13 1736.4 4902 80 15.05 1440 1734 13.17 / 349.18 2 47
8 13 995.9 5010 80 15.06 988 1190 14.36 / 350.37 2 45
9 13 447.3 5081 80 15.08 635 766 15.13 / 351.13 2 40
10 14 0.4 5137 172 15.07 358 928 16.06 / 352.06 2 117
Average= 13.54
(KJ/cycle)

Cycle 24 : GMT 11/ 1/2026 6:38: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 64.9 7 91 15.01 387 529 0.53 / 320.26 3 16
2 6 4678.2 573 112 14.48 3185 5165 5.69 / 325.42 2 37
3 6 3923.0 814 44 14.59 2747 1763 7.46 / 327.18 2 39
4 6 3160.2 1054 1 14.82 2354 35 7.49 / 327.22 2 26
5 7 3009.7 5135 80 14.98 2210 2648 10.14 / 329.87 2 41
6 13 2121.6 5340 80 14.95 1679 2008 12.15 / 331.88 2 45
7 13 1550.4 5440 80 14.95 1329 1589 13.74 / 333.47 2 47
8 13 989.9 5524 80 14.99 988 1185 14.92 / 334.65 2 45
9 13 40.6 5646 80 15.07 387 467 15.39 / 335.12 2 30
10 14 0.1 5658 163 15.04 362 887 16.28 / 336.00 2 103
Average= 13.44
(KJ/cycle)

Cycle 23 : GMT 7/ 1/2026 8:10: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 67.3 7 91 15.01 391 534 0.53 / 304.10 3 16
2 6 4688.5 569 112 14.48 3206 5199 5.73 / 309.30 2 37
3 6 3882.3 809 44 14.60 2712 1742 7.48 / 311.04 2 40
4 7 2999.6 2731 80 14.94 2210 2641 10.12 / 313.68 2 42
5 13 2061.7 2952 80 14.97 1632 1954 12.07 / 315.64 2 45
6 13 1490.2 3055 80 14.97 1300 1557 13.63 / 317.19 2 47
7 13 989.4 3125 80 14.99 982 1178 14.81 / 318.37 2 44
8 13 100.9 3238 80 15.07 414 499 15.31 / 318.87 2 32
9 14 0.7 3255 159 15.04 358 856 16.16 / 319.73 2 101
Average= 13.32
(KJ/cycle)

Cycle 22 : GMT 5/ 1/2026 1:43: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 64.3 7 91 15.02 389 532 0.53 / 287.71 3 17
2 6 4688.6 576 112 14.48 3204 5196 5.73 / 292.90 2 37
3 6 3878.6 816 44 14.60 2718 1746 7.47 / 294.65 2 40
4 6 3140.7 1057 1 14.81 2398 36 7.51 / 294.68 2 25
5 7 2986.5 2738 80 14.95 2198 2629 10.14 / 297.31 2 41
6 13 2068.2 2963 80 14.97 1642 1966 12.10 / 299.28 2 43
7 13 1526.8 3064 80 14.97 1311 1570 13.67 / 300.85 2 47
8 13 997.4 3140 80 15.00 987 1184 14.86 / 302.03 2 44
9 13 322.2 3224 80 15.05 554 667 15.53 / 302.70 2 37
10 14 0.6 3265 161 15.05 357 865 16.39 / 303.57 2 114
Average= 13.20
(KJ/cycle)

Cycle 21 : GMT 2/ 1/2026 19: 8: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 66.6 7 91 15.02 390 533 0.53 / 271.46 3 17
2 6 4680.9 576 112 14.48 3192 5177 5.71 / 276.64 2 38
3 6 3887.4 816 44 14.60 2716 1745 7.45 / 278.38 2 39
4 6 3121.1 1056 1 14.84 2363 35 7.49 / 278.42 2 26
5 7 2984.7 2617 80 14.96 2205 2639 10.13 / 281.06 2 42
6 13 2206.1 2795 80 14.95 1729 2068 12.20 / 283.13 2 45
7 13 1445.6 2928 80 14.98 1265 1516 13.71 / 284.64 2 45
8 13 984.8 2995 80 15.00 982 1178 14.89 / 285.82 2 43
9 13 60.8 3108 80 15.08 397 479 15.37 / 286.30 2 31
10 14 0.4 3122 163 15.05 357 876 16.25 / 287.17 2 111
Average= 13.05
(KJ/cycle)

Cycle 20 : GMT 31/12/2025 14:56: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 64.8 7 90 15.03 388 525 0.52 / 255.32 3 18
2 6 4636.9 559 112 14.49 3171 5146 5.67 / 260.47 2 38
3 6 3866.0 799 44 14.61 2707 1740 7.41 / 262.21 2 39
4 3 3034.6 1280 1 14.86 2249 33 7.44 / 262.24 2 24
5 7 3012.3 2600 80 14.95 2228 2665 10.11 / 264.91 2 42
6 13 2122.3 2800 80 14.96 1680 2011 12.12 / 266.92 2 45
7 13 1480.3 2913 80 14.98 1283 1538 13.66 / 268.46 2 47
8 13 999.9 2984 80 15.00 986 1183 14.84 / 269.64 2 43
9 13 19.5 3109 80 15.09 372 449 15.29 / 270.09 2 30
10 14 0.3 3119 157 15.05 356 841 16.13 / 270.93 2 110
Average= 12.90
(KJ/cycle)

Cycle 19 : GMT 29/12/2025 10:50: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 71.5 7 90 15.01 396 535 0.53 / 239.44 3 19
2 6 4595.3 554 112 14.50 3150 5116 5.65 / 244.56 2 38
3 6 3815.9 794 44 14.61 2680 1723 7.37 / 246.28 2 39
4 7 2971.8 2596 80 14.96 2188 2619 9.99 / 248.90 2 42
5 13 2012.9 2833 80 14.99 1600 1919 11.91 / 250.82 2 46
6 13 1591.9 2907 80 14.96 1349 1614 13.53 / 252.43 2 47
7 13 922.4 3000 80 15.02 938 1127 14.65 / 253.56 2 43
8 14 0.2 3126 232 15.07 355 1241 15.89 / 254.80 3 112
Average= 12.74
(KJ/cycle)

Cycle 18 : GMT 27/12/2025 6:34: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 65.4 7 91 15.01 395 540 0.54 / 223.63 3 18
2 6 4551.7 560 112 14.48 3122 5063 5.60 / 228.69 2 38
3 6 3773.3 800 43 14.61 2651 1665 7.27 / 230.36 2 39
4 6 3128.8 980 1 14.81 2377 35 7.30 / 230.39 2 25
5 7 2970.2 2481 80 14.97 2182 2613 9.92 / 233.01 2 42
6 13 2052.9 2707 80 14.98 1629 1952 11.87 / 234.96 2 44
7 13 1450.8 2813 80 14.98 1260 1510 13.38 / 236.47 2 47
8 13 990.1 2879 80 14.99 981 1176 14.56 / 237.64 2 44
9 14 0.2 3007 230 15.05 364 1260 15.82 / 238.90 2 114
Average= 12.57
(KJ/cycle)

Cycle 17 : GMT 25/12/2025 4:18:59

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 61.4 7 91 15.02 388 530 0.53 / 207.38 3 18
2 6 4550.6 547 112 14.48 3120 5060 5.59 / 212.44 2 37
3 6 3804.0 788 43 14.60 2681 1683 7.27 / 214.12 2 40
4 6 3224.4 968 1 14.81 2458 36 7.31 / 214.16 2 24
5 7 2974.1 2469 80 14.97 2193 2626 9.94 / 216.78 2 43
6 13 2116.4 2670 80 14.97 1674 2005 11.94 / 218.79 2 45
7 13 1494.7 2786 80 14.98 1293 1550 13.49 / 220.34 2 47
8 13 994.1 2857 80 15.00 978 1174 14.66 / 221.51 2 44
9 13 361.8 2937 80 15.05 581 700 15.36 / 222.21 2 38
10 14 0.1 2982 161 15.04 363 879 16.24 / 223.09 2 119
Average= 12.39
(KJ/cycle)

Cycle 16 : GMT 23/12/2025 2:30: 3

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 65.1 7 91 15.01 394 538 0.54 / 191.51 3 17
2 6 4515.6 536 112 14.49 3097 5026 5.56 / 196.54 2 38
3 6 3938.4 717 43 14.57 2761 1730 7.29 / 198.27 2 39
4 6 3263.6 897 1 14.78 2442 36 7.33 / 198.31 2 25
5 7 2993.0 2398 80 14.97 2198 2632 9.96 / 200.94 2 43
6 13 1992.8 2641 80 15.00 1599 1919 11.88 / 202.86 2 45
7 13 1393.4 2748 80 15.00 1230 1476 13.36 / 204.33 2 47
8 13 993.3 2811 80 15.00 980 1176 14.53 / 205.51 2 45
9 13 74.2 2927 80 15.08 404 487 15.02 / 206.00 2 32
10 14 0.4 2941 157 15.05 360 851 15.87 / 206.85 2 104
Average= 12.17
(KJ/cycle)

Cycle 15 : GMT 21/12/2025 1:18: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 68.3 7 91 15.01 396 541 0.54 / 175.68 2 18
2 6 4480.6 539 112 14.50 3082 5005 5.55 / 180.68 2 38
3 6 3910.5 719 43 14.58 2732 1713 7.26 / 182.40 2 40
4 6 3138.5 959 1 14.83 2389 35 7.29 / 182.43 2 25
5 7 2980.9 1921 80 14.92 2191 2615 9.91 / 185.05 2 43
6 13 1981.8 2158 80 14.98 1590 1905 11.81 / 186.95 2 45
7 13 1461.0 2251 80 14.97 1274 1526 13.34 / 188.48 2 47
8 13 961.6 2320 80 14.99 963 1155 14.50 / 189.63 2 45
9 13 61.1 2435 80 15.07 398 480 14.98 / 190.11 2 31
10 14 0.1 2450 157 15.04 365 862 15.84 / 190.98 2 101
Average= 11.94
(KJ/cycle)

Cycle 14 : GMT 19/12/2025 8:21: 2

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 63.2 7 91 15.00 392 535 0.54 / 159.58 3 19
2 6 4430.4 521 112 14.50 3058 4966 5.50 / 164.55 2 38
3 6 4047.4 641 43 14.54 2825 1766 7.27 / 166.31 2 38
4 6 3180.3 881 1 14.81 2401 36 7.30 / 166.35 2 25
5 7 2980.3 1902 80 14.92 2197 2622 9.93 / 168.97 2 43
6 13 2001.7 2138 80 14.98 1596 1913 11.84 / 170.88 2 45
7 13 1480.6 2231 80 14.97 1285 1539 13.38 / 172.42 2 47
8 13 1001.0 2300 80 14.99 987 1184 14.56 / 173.60 2 45
9 13 316.5 2387 80 15.05 557 671 15.23 / 174.28 2 38
10 14 0.5 2428 159 15.04 361 863 16.09 / 175.14 2 106
Average= 11.68
(KJ/cycle)

Cycle 13 : GMT 17/12/2025 15:44: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 61.8 7 91 15.00 397 542 0.54 / 143.47 2 19
2 6 4398.6 526 122 14.50 3040 5378 5.92 / 148.85 2 38
3 6 3774.4 706 1 14.76 2777 41 5.96 / 148.89 2 24
4 7 3497.8 1908 80 14.85 2493 2962 8.92 / 151.85 2 43
5 13 2541.4 2143 80 14.87 1921 2285 11.21 / 154.13 2 43
6 13 2000.2 2239 80 14.88 1596 1900 13.11 / 156.03 2 47
7 13 1000.0 2392 80 15.00 989 1187 14.29 / 157.22 2 47
8 13 530.1 2456 80 15.03 689 828 15.12 / 158.05 2 43
9 14 0.3 2522 183 15.03 362 996 16.12 / 159.04 2 108
Average= 11.36
(KJ/cycle)

Cycle 12 : GMT 15/12/2025 21:33: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 61.8 7 86 14.98 395 509 0.51 / 126.85 2 18
2 6 4403.1 497 123 14.51 3038 5422 5.93 / 132.27 2 38
3 3 3591.1 918 5 14.78 2593 192 6.12 / 132.46 2 39
4 7 3523.2 1879 80 14.85 2519 2993 9.12 / 135.46 2 42
5 13 2660.6 2095 80 14.85 2002 2378 11.49 / 137.84 2 44
6 13 1900.4 2236 80 14.91 1541 1838 13.33 / 139.67 2 46
7 13 1000.7 2381 80 15.01 991 1190 14.52 / 140.86 2 46
8 13 870.2 2400 80 14.97 911 1091 15.61 / 141.95 2 45
9 14 0.1 2505 176 15.04 367 971 16.58 / 142.93 2 107
Average= 10.99
(KJ/cycle)

Cycle 11 : GMT 14/12/2025 3:38: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 67.7 7 86 15.00 400 516 0.52 / 109.99 3 19
2 6 4415.7 506 77 14.59 3052 3429 3.94 / 113.41 2 37
3 3 4345.2 867 7 14.73 3012 311 4.26 / 113.73 2 38
4 3 4235.0 988 1 14.79 3011 45 4.30 / 113.77 2 23
5 7 4248.6 1828 80 14.76 2967 3503 7.80 / 117.27 2 41
6 13 3332.3 2046 80 14.70 2403 2826 10.63 / 120.10 2 44
7 13 2061.1 2325 80 14.90 1641 1956 12.59 / 122.06 2 44
8 13 1510.0 2424 80 14.92 1305 1558 14.14 / 123.61 2 47
9 13 989.8 2498 80 14.96 980 1173 15.32 / 124.79 2 44
10 13 355.3 2576 80 15.02 581 698 16.01 / 125.48 2 39
11 14 0.1 2621 157 15.01 364 858 16.87 / 126.34 2 107
Average= 10.53
(KJ/cycle)

Cycle 10 : GMT 12/12/2025 7:48:59

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 65.7 7 86 15.01 400 516 0.52 / 93.63 2 19
2 6 4437.6 518 76 14.59 3061 3394 3.91 / 97.02 2 37
3 3 4341.1 878 5 14.76 3030 224 4.13 / 97.24 2 37
4 3 4265.1 999 1 14.79 3082 46 4.18 / 97.29 2 24
5 7 4284.8 1839 80 14.76 2976 3514 7.69 / 100.80 2 40
6 13 3441.8 2040 80 14.69 2476 2910 10.60 / 103.71 2 42
7 13 2062.6 2351 80 14.91 1646 1963 12.57 / 105.68 2 45
8 13 1510.6 2448 80 14.93 1312 1567 14.13 / 107.24 2 47
9 13 1000.3 2524 80 14.96 989 1184 15.32 / 108.43 2 44
10 13 60.7 2641 80 15.05 396 477 15.79 / 108.91 2 32
11 14 0.7 2654 103 15.03 365 565 16.36 / 109.47 2 103
Average= 9.95
(KJ/cycle)

Cycle 9 : GMT 10/12/2025 11:27: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 68.8 7 136 14.99 405 826 0.83 / 80.37 3 20
2 6 4012.1 556 65 14.67 2812 2681 3.51 / 83.05 2 38
3 7 3486.2 1638 80 14.82 2511 2977 6.48 / 86.03 2 42
4 13 2440.6 1898 80 14.88 1871 2227 8.71 / 88.25 2 44
5 13 1870.3 2003 80 14.90 1529 1823 10.53 / 90.08 2 45
6 13 1000.0 2145 80 15.00 994 1193 11.73 / 91.27 2 43
7 13 770.5 2175 80 14.99 849 1018 12.74 / 92.29 2 43
8 14 0.3 2269 149 15.04 368 825 13.57 / 93.11 2 103
Average= 9.31
(KJ/cycle)

Cycle 8 : GMT 8/12/2025 21:29: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 62.7 7 135 14.98 404 817 0.82 / 66.67 2 21
2 6 4002.3 541 64 14.66 2814 2640 3.46 / 69.31 2 38
3 3 3526.3 902 1 14.85 2649 39 3.50 / 69.35 2 23
4 7 3535.9 1623 80 14.81 2549 3020 6.52 / 72.37 2 41
5 13 2580.6 1847 80 14.85 1966 2336 8.85 / 74.70 2 44
6 13 1999.8 1953 80 14.88 1608 1914 10.77 / 76.62 2 46
7 13 1000.3 2109 80 15.00 992 1190 11.96 / 77.81 2 44
8 13 690.5 2151 80 15.00 800 960 12.92 / 78.77 2 42
9 14 0.4 2236 138 15.04 372 772 13.69 / 79.54 2 101
Average= 8.84
(KJ/cycle)

Cycle 7 : GMT 7/12/2025 8: 3: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 65.0 7 132 14.99 403 797 0.80 / 52.64 2 20
2 6 4012.2 542 64 14.66 2830 2655 3.45 / 55.29 2 38
3 6 3848.5 602 1 14.79 2809 42 3.49 / 55.34 2 23
4 3 3543.3 903 2 14.85 2644 79 3.57 / 55.41 2 24
5 3 3520.3 1023 1 14.85 2653 39 3.61 / 55.45 2 23
6 7 3516.6 1624 80 14.82 2529 2998 6.61 / 58.45 2 41
7 13 2641.2 1829 80 14.83 1999 2372 8.98 / 60.82 2 43
8 13 2000.8 1947 80 14.87 1622 1930 10.91 / 62.75 2 47
9 13 999.5 2103 80 14.99 999 1198 12.11 / 63.95 2 44
10 13 830.4 2125 80 14.96 895 1071 13.18 / 65.02 2 44
11 14 0.3 2225 148 15.03 373 830 14.01 / 65.85 2 107
Average= 8.23
(KJ/cycle)

Cycle 6 : GMT 5/12/2025 18:48: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 62.3 7 118 15.11 408 727 0.73 / 37.97 3 19
2 6 4002.4 500 65 14.71 2823 2699 3.43 / 40.67 2 38
3 3 3798.7 861 16 14.78 2675 633 4.06 / 41.30 2 38
4 3 3602.2 982 5 14.83 2623 194 4.25 / 41.49 2 38
5 7 3475.6 1582 80 14.83 2509 2977 7.23 / 44.47 2 42
6 13 2522.7 1805 80 14.86 1932 2297 9.53 / 46.77 2 43
7 13 2000.6 1903 80 14.88 1617 1925 11.45 / 48.69 2 46
8 13 999.9 2058 80 15.00 1002 1202 12.65 / 49.89 2 44
9 13 890.2 2073 80 14.95 933 1116 13.77 / 51.01 2 44
10 14 0.5 2181 147 15.03 377 833 14.60 / 51.84 2 102
Average= 7.41
(KJ/cycle)

Cycle 5 : GMT 4/12/2025 6:20: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 64.1 7 303 15.07 413 1886 1.89 / 33.12 2 20
2 6 1012.1 202 42 15.09 1005 637 2.52 / 33.75 2 30
3 6 901.5 262 1 15.14 970 15 2.54 / 33.77 2 23
4 7 765.0 923 80 15.25 851 1038 3.58 / 34.81 2 37
5 13 738.0 929 80 15.20 830 1009 4.58 / 35.82 3 36
6 13 241.2 995 80 15.18 517 628 5.21 / 36.44 2 34
7 14 0.2 1027 140 15.15 375 795 6.01 / 37.24 2 101
Average= 6.21
(KJ/cycle)

Cycle 4 : GMT 3/12/2025 13: 6:59

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 64.4 7 302 15.07 424 1930 1.93 / 26.99 3 20
2 6 1002.7 197 43 15.09 999 648 2.58 / 27.64 2 29
3 7 815.4 918 80 15.24 887 1081 3.66 / 28.72 2 36
4 13 787.7 924 80 15.18 868 1054 4.71 / 29.78 3 36
5 13 242.8 996 80 15.18 525 638 5.35 / 30.41 2 34
6 14 0.2 1029 142 15.15 380 817 6.17 / 31.23 3 106
Average= 6.25
(KJ/cycle)

Cycle 3 : GMT 2/12/2025 19:50: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 62.3 7 298 15.09 427 1920 1.92 / 20.83 3 19
2 6 1002.8 181 43 15.10 1007 654 2.57 / 21.49 2 28
3 6 924.9 241 1 15.15 991 15 2.59 / 21.50 2 22
4 3 862.2 422 3 15.17 994 45 2.63 / 21.55 2 22
5 7 818.4 903 80 15.24 905 1103 3.74 / 22.65 2 36
6 13 788.5 909 80 15.19 883 1073 4.81 / 23.72 3 36
7 13 57.1 1005 80 15.19 418 508 5.32 / 24.23 2 31
8 14 0.2 1018 140 15.15 391 829 6.15 / 25.06 3 103
Average= 6.27
(KJ/cycle)

Cycle 2 : GMT 2/12/2025 2:45: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 59.8 7 299 15.08 436 1966 1.97 / 14.77 3 20
2 6 1002.5 185 60 15.02 1037 935 2.90 / 15.71 2 29
3 7 569.7 1147 80 15.29 759 928 3.83 / 16.63 2 33
4 13 546.0 1153 80 15.23 741 903 4.73 / 17.54 3 33
5 13 87.1 1212 80 15.20 443 539 5.27 / 18.08 2 31
6 14 0.2 1228 140 15.16 395 838 6.11 / 18.91 2 101
Average= 6.30
(KJ/cycle)

Cycle 1 : GMT 1/12/2025 6:10: 2

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 60.8 7 284 15.03 420 1793 1.79 / 8.25 3 18
2 6 1002.4 162 60 15.01 1034 931 2.72 / 9.18 2 27
3 3 920.3 402 16 15.16 1010 245 2.97 / 9.43 2 33
4 3 694.1 523 4 15.21 881 54 3.02 / 9.48 2 31
5 7 577.5 1124 80 15.30 784 960 3.98 / 10.44 2 34
6 13 555.2 1130 80 15.23 762 928 4.91 / 11.37 3 33
7 14 0.3 1210 228 15.17 415 1435 6.35 / 12.81 3 103
Average= 6.40
(KJ/cycle)

Cycle 0 : GMT 30/11/2025 9:51: 2

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 13 202.2 64173 407 15.39 515 3226 3.23 / 3.23 3 17
2 7 289.1 64180 80 15.26 540 659 3.89 / 3.89 3 16
3 13 322.3 64186 80 15.22 563 686 4.57 / 4.57 3 17
4 13 306.7 64195 80 15.18 541 657 5.23 / 5.23 3 22
5 14 1.0 64238 219 15.12 372 1232 6.46 / 6.46 3 107
Average= 6.46
(KJ/cycle)