SIO Argo Site:
Pump Diagnostics







Serial= 3379 - WMO= 6990650


Cycle 31 : GMT 9/11/2026 9:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.32 32 14.76 483 228 0.23 / 126.23 2 4
2 7 2005.68 38 14.32 2615 1423 1.65 / 127.65 2 4
3 13 1608.20 18 14.39 2302 596 2.25 / 128.24 2 7
4 13 1187.36 18 14.43 1862 484 2.73 / 128.73 2 8
5 13 618.16 18 14.62 1176 309 3.04 / 129.04 2 13
6 13 33.12 18 14.90 356 95 3.14 / 129.13 2 21
7 8 0.36 165 14.86 303 743 3.88 / 129.88 2 26
Average= 4.06
(KJ/cycle)

Cycle 30 : GMT 30/10/2026 15:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.64 32 14.78 501 237 0.24 / 122.34 2 6
2 7 2016.16 38 14.33 2588 1409 1.65 / 123.75 2 4
3 13 1612.40 18 14.38 2267 587 2.23 / 124.33 2 8
4 13 1196.12 18 14.43 1891 491 2.72 / 124.82 2 9
5 13 613.56 18 14.63 1183 312 3.04 / 125.14 2 13
6 8 -0.08 165 14.88 297 729 3.76 / 125.86 2 24
7 14 -0.08 30 14.85 297 132 3.90 / 126.00 3 24
Average= 4.06
(KJ/cycle)

Cycle 29 : GMT 20/10/2026 21:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.08 32 14.77 499 236 0.24 / 118.47 2 5
2 7 2005.52 39 14.33 2602 1454 1.69 / 119.92 2 5
3 13 1731.84 18 14.35 2394 618 2.31 / 120.54 2 8
4 13 1156.20 18 14.45 1849 481 2.79 / 121.02 2 10
5 13 590.24 18 14.65 1154 304 3.09 / 121.33 2 13
6 8 -0.08 165 14.88 315 773 3.87 / 122.10 2 24
Average= 4.07
(KJ/cycle)

Cycle 28 : GMT 11/10/2026 2:59: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.96 32 14.76 515 243 0.24 / 114.57 2 8
2 7 2014.36 38 14.34 2609 1422 1.66 / 115.99 2 4
3 13 1598.80 18 14.38 2302 596 2.26 / 116.58 2 8
4 13 1181.24 18 14.45 1846 480 2.74 / 117.06 2 9
5 13 611.76 18 14.64 1176 310 3.05 / 117.37 2 13
6 13 16.88 18 14.91 336 90 3.14 / 117.46 2 14
7 8 0.16 165 14.86 314 770 3.91 / 118.23 2 24
Average= 4.08
(KJ/cycle)

Cycle 27 : GMT 1/10/2026 8:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.12 33 14.76 499 243 0.24 / 110.71 2 7
2 3 963.08 -1 15.32 0 0 0.00 / 110.71 2 7
3 3 1024.24 1 14.87 1714 25 0.27 / 110.74 2 4
4 7 2012.60 38 14.34 2613 1424 1.69 / 112.16 2 4
5 13 1617.64 18 14.38 2332 604 2.30 / 112.77 2 7
6 13 1072.32 18 14.48 1747 455 2.75 / 113.22 2 9
7 13 649.64 18 14.62 1212 319 3.07 / 113.54 2 13
8 8 0.28 165 14.87 318 780 3.85 / 114.32 2 25
Average= 4.08
(KJ/cycle)

Cycle 26 : GMT 21/ 9/2026 14: 6: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.04 32 14.76 486 230 0.23 / 106.74 2 4
2 10 1004.04 2 14.76 1725 51 0.28 / 106.79 2 4
3 3 956.24 -1 15.37 0 0 0.05 / 106.79 2 4
4 7 2003.08 38 14.32 2611 1421 1.70 / 108.21 2 5
5 13 1583.40 18 14.42 2259 586 2.29 / 108.80 2 8
6 13 1153.32 18 14.46 1833 477 2.76 / 109.27 2 10
7 13 593.52 18 14.64 1163 306 3.07 / 109.58 2 14
8 13 28.44 18 14.90 377 101 3.17 / 109.68 2 8
9 8 0.20 165 14.86 322 790 3.96 / 110.47 2 22
Average= 4.09
(KJ/cycle)

Cycle 25 : GMT 11/ 9/2026 19:42:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.36 31 14.78 514 236 0.24 / 102.52 2 4
2 10 1002.96 3 14.71 1724 76 0.31 / 102.59 2 4
3 3 974.36 -1 15.37 0 0 0.08 / 102.59 2 4
4 7 2007.80 38 14.35 2585 1410 1.72 / 104.00 2 3
5 13 1740.64 18 14.36 2448 633 2.35 / 104.64 2 6
6 13 1434.36 18 14.39 2128 551 2.91 / 105.19 2 9
7 13 575.44 18 14.67 1129 298 3.20 / 105.49 2 12
8 13 52.36 18 14.90 402 108 3.31 / 105.59 2 12
9 8 0.08 165 14.87 315 773 4.08 / 106.37 2 26
10 14 0.08 30 14.84 321 143 4.23 / 106.51 5 27
Average= 4.10
(KJ/cycle)

Cycle 24 : GMT 2/ 9/2026 1:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.64 31 14.73 539 246 0.25 / 98.47 2 5
2 7 2009.80 38 14.35 2582 1408 1.65 / 99.88 2 4
3 13 1727.20 18 14.38 2387 618 2.27 / 100.50 2 5
4 13 1159.72 18 14.46 1861 484 2.76 / 100.98 2 11
5 13 890.20 18 14.53 1539 403 3.16 / 101.38 2 12
6 13 22.20 18 14.92 360 97 3.26 / 101.48 2 9
7 8 0.12 165 14.87 327 802 4.06 / 102.28 2 25
Average= 4.09
(KJ/cycle)

Cycle 23 : GMT 23/ 8/2026 7:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.72 30 14.75 539 239 0.24 / 94.36 2 10
2 10 1017.08 2 14.69 1787 53 0.29 / 94.41 2 6
3 7 2007.72 39 14.31 2640 1473 1.76 / 95.88 2 4
4 13 1589.20 18 14.36 2332 603 2.37 / 96.48 2 5
5 13 1043.40 18 14.48 1747 455 2.82 / 96.94 2 10
6 13 612.04 18 14.62 1215 320 3.14 / 97.26 2 14
7 13 69.00 18 14.87 458 123 3.26 / 97.38 2 17
8 8 0.28 165 14.84 344 842 4.11 / 98.22 2 23
Average= 4.09
(KJ/cycle)

Cycle 22 : GMT 13/ 8/2026 12:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.32 30 14.73 565 250 0.25 / 90.21 2 7
2 7 2004.40 38 14.33 2632 1433 1.68 / 91.64 2 5
3 13 1591.96 18 14.37 2346 607 2.29 / 92.25 2 8
4 13 1047.48 18 14.48 1728 450 2.74 / 92.70 2 11
5 13 630.44 18 14.61 1234 325 3.06 / 93.02 2 14
6 13 38.92 18 14.89 409 110 3.17 / 93.13 2 17
7 8 -0.16 165 14.85 342 838 4.01 / 93.97 2 29
8 14 -0.16 30 14.83 337 150 4.16 / 94.12 5 25
Average= 4.09
(KJ/cycle)

Cycle 21 : GMT 3/ 8/2026 18:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.24 29 14.72 561 239 0.24 / 86.08 2 12
2 3 1016.24 1 14.83 1748 26 0.27 / 86.10 2 6
3 7 2009.68 38 14.34 2624 1430 1.70 / 87.53 2 5
4 13 1592.68 18 14.39 2286 592 2.29 / 88.13 2 8
5 13 1162.40 18 14.45 1890 492 2.78 / 88.62 2 11
6 13 720.16 18 14.56 1353 355 3.13 / 88.97 2 14
7 13 61.56 18 14.87 457 122 3.26 / 89.09 2 18
8 8 0.48 165 14.84 352 862 4.12 / 89.96 2 23
Average= 4.09
(KJ/cycle)

Cycle 20 : GMT 24/ 7/2026 23:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.68 30 14.76 537 238 0.24 / 81.92 2 8
2 7 2008.56 38 14.32 2664 1450 1.69 / 83.37 2 6
3 13 1878.80 18 14.34 2511 648 2.34 / 84.02 2 5
4 13 1132.20 18 14.46 1832 477 2.81 / 84.50 2 10
5 13 591.96 18 14.63 1199 316 3.13 / 84.81 2 15
6 13 173.76 18 14.81 633 169 3.30 / 84.98 2 19
7 8 0.00 165 14.85 350 858 4.15 / 85.84 2 29
Average= 4.09
(KJ/cycle)

Cycle 19 : GMT 15/ 7/2026 5:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.80 29 14.72 547 234 0.23 / 77.90 2 7
2 3 1018.60 1 14.85 1728 26 0.26 / 77.92 2 6
3 7 2013.72 38 14.32 2652 1443 1.70 / 79.37 2 6
4 13 1599.04 18 14.40 2320 601 2.30 / 79.97 2 8
5 13 1013.04 18 14.50 1718 448 2.75 / 80.42 2 11
6 13 455.12 18 14.70 1024 271 3.02 / 80.69 2 17
7 13 37.48 18 14.90 429 115 3.14 / 80.80 2 21
8 8 -0.28 165 14.85 359 880 4.02 / 81.68 2 24
Average= 4.08
(KJ/cycle)

Cycle 18 : GMT 5/ 7/2026 10:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.44 28 14.75 544 225 0.22 / 73.72 2 5
2 3 1033.28 1 14.78 1810 27 0.25 / 73.75 2 6
3 7 2011.56 38 14.35 2590 1412 1.66 / 75.16 2 6
4 13 1469.00 18 14.42 2187 568 2.23 / 75.73 2 8
5 13 1061.24 18 14.49 1764 460 2.69 / 76.19 2 11
6 13 638.12 18 14.61 1250 329 3.02 / 76.51 2 15
7 13 89.24 18 14.86 501 134 3.15 / 76.65 2 12
8 8 0.24 165 14.85 350 858 4.01 / 77.51 2 26
9 14 0.24 30 14.81 358 159 4.17 / 77.67 5 26
Average= 4.09
(KJ/cycle)

Cycle 17 : GMT 25/ 6/2026 15:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.84 29 14.74 547 234 0.23 / 69.53 2 9
2 3 971.92 -1 15.33 0 0 0.00 / 69.53 2 9
3 7 2007.08 38 14.34 2615 1425 1.66 / 70.95 2 5
4 13 1588.56 18 14.38 2324 602 2.26 / 71.55 2 6
5 13 1147.80 18 14.47 1874 488 2.75 / 72.04 2 13
6 13 564.52 18 14.66 1168 308 3.06 / 72.35 2 15
7 13 73.48 18 14.89 472 127 3.18 / 72.47 2 21
8 8 0.16 165 14.87 352 864 4.05 / 73.34 2 32
9 14 0.16 30 14.84 351 156 4.20 / 73.49 4 29
Average= 4.08
(KJ/cycle)

Cycle 16 : GMT 15/ 6/2026 21:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.60 30 14.74 524 232 0.23 / 65.51 2 5
2 3 975.00 -1 15.32 0 0 0.00 / 65.51 2 5
3 3 1016.24 1 14.90 1776 26 0.26 / 65.53 2 5
4 7 2006.12 38 14.34 2633 1435 1.69 / 66.97 2 5
5 13 1438.88 18 14.44 2176 566 2.26 / 67.53 2 9
6 13 1023.28 18 14.51 1727 451 2.71 / 67.98 2 13
7 13 577.16 18 14.65 1166 307 3.02 / 68.29 2 16
8 13 69.12 18 14.89 470 126 3.14 / 68.42 2 18
9 8 0.16 165 14.86 357 875 4.02 / 69.29 2 27
Average= 4.08
(KJ/cycle)

Cycle 15 : GMT 6/ 6/2026 2:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.40 32 14.74 527 249 0.25 / 60.82 2 5
2 3 948.68 -1 15.41 0 0 0.00 / 60.82 2 5
3 7 2013.12 74 14.23 2605 2743 2.99 / 63.56 2 6
4 13 639.28 18 14.65 1244 328 3.32 / 63.89 2 12
5 13 123.04 18 14.87 538 144 3.46 / 64.04 2 18
6 8 0.00 165 14.87 348 854 4.32 / 64.89 2 23
7 14 0.00 75 14.82 345 383 4.70 / 65.27 5 27
Average= 4.08
(KJ/cycle)

Cycle 14 : GMT 27/ 5/2026 5:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.96 32 14.77 524 248 0.25 / 55.99 2 4
2 7 2005.76 74 14.24 2589 2728 2.98 / 58.72 2 8
3 13 787.48 18 14.61 1390 366 3.34 / 59.09 2 12
4 13 199.48 18 14.85 647 173 3.51 / 59.26 2 16
5 13 35.20 18 14.91 399 107 3.62 / 59.37 2 15
6 8 0.16 165 14.87 338 829 4.45 / 60.20 2 24
7 14 0.16 75 14.82 337 375 4.83 / 60.57 3 26
Average= 4.04
(KJ/cycle)

Cycle 13 : GMT 17/ 5/2026 7:52: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.72 32 14.84 510 242 0.24 / 51.61 2 5
2 7 2008.08 74 14.22 2672 2812 3.05 / 54.42 2 7
3 13 773.16 18 14.59 1427 375 3.43 / 54.80 2 12
4 13 110.08 18 14.89 515 138 3.57 / 54.94 2 13
5 8 0.32 165 14.88 330 810 4.38 / 55.75 2 29
Average= 3.98
(KJ/cycle)

Cycle 12 : GMT 7/ 5/2026 10:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.20 32 14.81 494 234 0.23 / 47.28 2 5
2 7 2004.68 74 14.26 2661 2808 3.04 / 50.09 2 7
3 13 791.68 18 14.63 1453 383 3.42 / 50.47 2 12
4 13 92.92 18 14.93 470 126 3.55 / 50.60 2 12
5 8 -0.08 165 14.92 314 773 4.32 / 51.37 2 26
Average= 3.95
(KJ/cycle)

Cycle 11 : GMT 27/ 4/2026 12:56: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.24 32 14.79 501 237 0.24 / 42.62 2 5
2 7 2007.40 74 14.25 2667 2812 3.05 / 45.43 2 7
3 13 801.36 18 14.61 1461 384 3.43 / 45.81 2 12
4 13 85.20 18 14.93 459 123 3.56 / 45.94 2 12
5 8 0.04 165 14.92 309 761 4.32 / 46.70 3 24
6 14 0.04 75 14.87 312 348 4.67 / 47.05 2 21
Average= 3.92
(KJ/cycle)

Cycle 10 : GMT 17/ 4/2026 15:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.36 32 14.82 506 240 0.24 / 37.92 2 5
2 7 2004.80 74 14.24 2672 2816 3.06 / 40.74 2 7
3 13 772.48 18 14.63 1415 373 3.43 / 41.11 2 11
4 13 79.44 18 14.93 450 121 3.55 / 41.23 2 13
5 8 0.16 165 14.91 319 785 4.33 / 42.02 2 23
6 14 0.16 75 14.85 325 362 4.70 / 42.38 3 30
Average= 3.85
(KJ/cycle)

Cycle 9 : GMT 7/ 4/2026 18:19: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.12 32 14.81 493 234 0.23 / 33.53 2 6
2 10 1019.80 2 14.83 1758 52 0.29 / 33.59 2 4
3 3 954.92 -1 15.43 0 0 0.05 / 33.59 2 4
4 7 2005.28 74 14.24 2684 2828 3.11 / 36.41 2 7
5 13 774.04 18 14.63 1408 371 3.48 / 36.79 2 12
6 13 76.84 18 14.93 441 119 3.60 / 36.90 2 9
7 8 0.08 165 14.92 317 780 4.38 / 37.68 2 25
Average= 3.77
(KJ/cycle)

Cycle 8 : GMT 28/ 3/2026 21:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.68 32 14.83 520 247 0.25 / 29.26 2 4
2 7 2011.96 74 14.26 2672 2820 3.07 / 32.07 2 7
3 13 683.60 18 14.68 1295 342 3.41 / 32.42 2 10
4 13 50.64 18 14.95 402 108 3.52 / 32.53 2 10
5 8 0.12 165 14.92 315 775 4.29 / 33.30 2 22
Average= 3.70
(KJ/cycle)

Cycle 7 : GMT 18/ 3/2026 23:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.76 31 14.84 507 233 0.23 / 24.91 2 4
2 3 1017.56 1 15.00 1765 26 0.26 / 24.93 2 5
3 7 2008.52 74 14.27 2641 2789 3.05 / 27.72 2 7
4 13 789.60 18 14.63 1436 378 3.43 / 28.10 2 11
5 13 88.16 18 14.93 461 124 3.55 / 28.23 2 13
6 8 0.08 165 14.92 318 783 4.33 / 29.01 2 19
Average= 3.63
(KJ/cycle)

Cycle 6 : GMT 9/ 3/2026 2:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.40 30 14.81 498 221 0.22 / 20.53 2 4
2 10 1008.84 2 14.77 1746 52 0.27 / 20.58 2 5
3 7 2005.00 74 14.25 2689 2836 3.11 / 23.41 2 7
4 13 789.16 18 14.61 1432 377 3.48 / 23.79 2 11
5 13 78.28 18 14.94 443 119 3.60 / 23.91 2 14
6 8 0.12 165 14.93 311 766 4.37 / 24.68 2 20
Average= 3.53
(KJ/cycle)

Cycle 5 : GMT 27/ 2/2026 5:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.48 33 14.81 505 247 0.25 / 15.82 2 5
2 3 914.16 -2 15.46 0 0 0.00 / 15.82 2 5
3 7 2009.80 74 14.26 2648 2794 3.04 / 18.61 2 8
4 13 813.64 18 14.61 1474 388 3.43 / 19.00 2 12
5 13 96.80 18 14.93 490 132 3.56 / 19.13 2 13
6 8 0.60 165 14.91 334 822 4.38 / 19.95 2 24
7 14 0.60 75 14.86 317 353 4.74 / 20.30 4 30
Average= 3.38
(KJ/cycle)

Cycle 4 : GMT 17/ 2/2026 8:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.92 30 14.84 496 221 0.22 / 11.74 2 4
2 7 1507.88 74 14.41 2286 2438 2.66 / 14.17 2 9
3 13 357.88 18 14.83 852 227 2.89 / 14.40 2 12
4 8 1.68 165 14.93 325 801 3.69 / 15.20 2 25
5 14 1.68 75 14.88 329 367 4.05 / 15.57 5 28
Average= 3.11
(KJ/cycle)

Cycle 3 : GMT 16/ 2/2026 8:50: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.44 30 14.82 467 208 0.21 / 8.15 2 4
2 7 1506.64 75 14.42 2251 2434 2.64 / 10.58 2 10
3 13 327.48 18 14.84 778 208 2.85 / 10.79 2 12
4 8 0.00 165 14.95 295 728 3.58 / 11.52 2 22
Average= 2.88
(KJ/cycle)

Cycle 2 : GMT 15/ 2/2026 9:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.96 35 14.81 462 239 0.24 / 4.60 2 5
2 3 786.96 -4 15.43 0 0 0.00 / 4.60 2 5
3 7 1509.36 74 14.40 2268 2417 2.66 / 7.02 2 10
4 13 343.24 18 14.83 796 212 2.87 / 7.23 2 12
5 8 0.08 165 14.93 286 705 3.57 / 7.94 2 25
Average= 2.65
(KJ/cycle)

Cycle 1 : GMT 14/ 2/2026 9:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.80 30 15.04 414 187 0.19 / 1.83 3 3
2 3 972.52 -1 15.39 0 0 0.00 / 1.83 3 3
3 3 1023.96 1 14.93 1763 26 0.21 / 1.86 2 4
4 7 1002.24 74 14.57 1671 1802 2.01 / 3.66 2 11
5 8 0.00 165 14.93 286 705 2.72 / 4.36 2 21
Average= 2.18
(KJ/cycle)

Cycle 0 : GMT 13/ 2/2026 23:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 162.08 30 15.27 493 226 0.23 / 0.23 3 12
2 7 175.72 74 15.20 501 564 0.79 / 0.79 3 7
3 8 0.20 240 15.18 235 856 1.65 / 1.65 3 35
Average= 1.65
(KJ/cycle)