SIO Argo Site:
Pump Diagnostics







Serial= 3274 - WMO= 6990604


Cycle 73 : GMT 5/ 9/2026 1:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.32 35 15.10 466 246 0.25 / 279.84 2 3
2 7 2004.88 38 14.90 2887 1635 1.88 / 281.47 2 9
3 13 1397.28 18 14.93 2158 580 2.46 / 282.05 2 12
4 13 870.28 18 15.00 1477 399 2.86 / 282.45 2 12
5 13 150.00 18 15.15 528 144 3.00 / 282.59 2 11
6 8 0.16 165 15.14 326 814 3.82 / 283.41 2 17
Average= 3.83
(KJ/cycle)

Cycle 72 : GMT 26/ 8/2026 6:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.52 35 15.09 450 238 0.24 / 275.95 2 3
2 3 1020.32 1 15.17 1687 26 0.26 / 275.98 2 5
3 7 2011.16 38 14.90 2881 1631 1.89 / 277.61 2 8
4 13 1406.56 18 14.92 2156 579 2.47 / 278.19 2 8
5 13 923.68 18 14.98 1560 421 2.89 / 278.61 2 12
6 13 234.28 18 15.14 645 176 3.07 / 278.78 2 11
7 8 -0.24 165 15.14 323 807 3.88 / 279.59 3 12
Average= 3.83
(KJ/cycle)

Cycle 71 : GMT 16/ 8/2026 11:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.36 35 15.10 477 252 0.25 / 272.13 2 3
2 7 2006.72 38 14.91 2869 1626 1.88 / 273.76 2 7
3 13 1398.60 18 14.94 2145 577 2.45 / 274.33 2 8
4 13 870.84 18 15.00 1482 400 2.85 / 274.74 2 10
5 13 269.12 18 15.12 693 189 3.04 / 274.92 2 9
6 8 0.52 165 15.15 316 790 3.83 / 275.71 2 14
Average= 3.83
(KJ/cycle)

Cycle 70 : GMT 6/ 8/2026 16:11: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.56 35 15.11 462 244 0.24 / 268.35 2 3
2 7 2013.08 38 14.90 2899 1641 1.89 / 269.99 2 8
3 13 1413.40 18 14.92 2173 584 2.47 / 270.58 2 13
4 13 846.00 18 15.01 1448 391 2.86 / 270.97 2 11
5 13 133.72 18 15.17 494 135 3.00 / 271.10 2 10
6 8 -0.08 165 15.16 311 778 3.77 / 271.88 2 15
Average= 3.83
(KJ/cycle)

Cycle 69 : GMT 27/ 7/2026 20:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.28 35 15.10 468 247 0.25 / 264.51 2 3
2 7 2013.20 38 14.91 2908 1648 1.89 / 266.16 2 8
3 13 1443.36 18 14.93 2236 601 2.50 / 266.76 2 14
4 13 908.76 18 15.00 1546 417 2.91 / 267.17 2 10
5 13 198.12 18 15.16 586 160 3.07 / 267.33 2 9
6 8 0.08 165 15.17 309 773 3.85 / 268.11 2 12
Average= 3.83
(KJ/cycle)

Cycle 68 : GMT 18/ 7/2026 1:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.68 34 15.12 451 232 0.23 / 260.66 2 3
2 3 1021.56 1 15.21 1649 25 0.26 / 260.69 2 3
3 7 2004.28 38 14.92 2879 1632 1.89 / 262.32 2 10
4 13 1356.80 18 14.95 2127 572 2.46 / 262.89 2 6
5 13 922.72 18 15.00 1549 418 2.88 / 263.31 2 8
6 13 188.16 18 15.17 569 155 3.04 / 263.47 2 8
7 8 0.00 165 15.16 318 795 3.83 / 264.26 3 10
Average= 3.83
(KJ/cycle)

Cycle 67 : GMT 8/ 7/2026 6:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.68 35 15.11 477 252 0.25 / 256.79 2 3
2 7 2005.20 38 14.92 2915 1653 1.90 / 258.45 2 8
3 13 1415.44 18 14.96 2199 592 2.50 / 259.04 2 11
4 13 892.56 18 15.01 1517 410 2.91 / 259.45 2 10
5 13 259.20 18 15.15 681 186 3.09 / 259.63 2 10
6 8 0.16 165 15.17 318 796 3.89 / 260.43 2 14
Average= 3.83
(KJ/cycle)

Cycle 66 : GMT 28/ 6/2026 11:19:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.08 35 15.10 452 239 0.24 / 252.98 2 3
2 3 1016.08 1 15.19 1670 25 0.26 / 253.00 2 3
3 7 2010.12 38 14.90 2891 1637 1.90 / 254.64 2 6
4 13 1337.52 18 14.94 2089 562 2.46 / 255.20 2 10
5 13 903.04 18 14.98 1525 411 2.87 / 255.61 2 12
6 13 160.28 18 15.18 537 147 3.02 / 255.76 2 10
7 8 0.24 165 15.16 313 783 3.80 / 256.54 2 10
Average= 3.83
(KJ/cycle)

Cycle 65 : GMT 18/ 6/2026 15:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.48 35 15.13 441 234 0.23 / 249.10 2 3
2 7 2003.24 38 14.92 2892 1640 1.87 / 250.74 2 11
3 13 1455.20 18 14.93 2218 596 2.47 / 251.34 2 12
4 13 922.32 18 14.99 1545 417 2.89 / 251.76 2 10
5 13 276.20 18 15.14 700 191 3.08 / 251.95 2 10
6 8 0.28 165 15.14 316 789 3.87 / 252.74 2 16
Average= 3.83
(KJ/cycle)

Cycle 64 : GMT 8/ 6/2026 20:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.40 34 15.12 460 236 0.24 / 245.28 2 3
2 3 1019.60 1 15.22 1653 25 0.26 / 245.31 2 4
3 7 2004.72 38 14.93 2880 1634 1.90 / 246.94 2 10
4 13 1444.92 18 14.95 2214 596 2.49 / 247.54 2 9
5 13 855.24 18 15.03 1473 399 2.89 / 247.94 2 8
6 13 138.84 18 15.20 512 140 3.03 / 248.08 2 8
7 8 0.00 165 15.17 318 796 3.83 / 248.87 2 12
Average= 3.83
(KJ/cycle)

Cycle 63 : GMT 30/ 5/2026 1:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.40 33 15.11 446 222 0.22 / 241.46 2 3
2 3 1037.12 1 15.20 1702 26 0.25 / 241.49 2 6
3 7 2006.04 38 14.92 2879 1632 1.88 / 243.12 2 7
4 13 1452.80 18 14.94 2209 594 2.47 / 243.71 2 9
5 13 871.52 18 15.02 1470 397 2.87 / 244.11 2 12
6 13 227.24 18 15.17 605 165 3.04 / 244.27 2 9
7 8 0.28 165 15.17 308 771 3.81 / 245.05 2 14
Average= 3.83
(KJ/cycle)

Cycle 62 : GMT 20/ 5/2026 6:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.00 34 15.11 470 241 0.24 / 237.63 2 3
2 3 955.68 -1 15.50 0 0 0.00 / 237.63 2 3
3 7 2004.96 38 14.92 2909 1649 1.89 / 239.28 2 6
4 13 1407.76 18 14.95 2167 583 2.47 / 239.86 2 10
5 13 878.76 18 15.02 1493 404 2.88 / 240.27 2 9
6 13 232.24 18 15.17 636 174 3.05 / 240.44 2 9
7 8 -0.16 165 15.17 318 796 3.85 / 241.24 2 15
Average= 3.83
(KJ/cycle)

Cycle 61 : GMT 10/ 5/2026 11:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.16 34 15.13 460 237 0.24 / 233.84 2 3
2 7 2007.08 38 14.93 2886 1637 1.87 / 235.48 2 15
3 13 1405.92 18 14.95 2136 575 2.45 / 236.05 2 12
4 13 833.36 18 15.03 1420 384 2.83 / 236.44 2 7
5 13 239.20 18 15.17 636 174 3.01 / 236.61 2 9
6 8 0.04 165 15.17 311 778 3.79 / 237.39 3 11
Average= 3.83
(KJ/cycle)

Cycle 60 : GMT 30/ 4/2026 16:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.84 34 15.11 464 238 0.24 / 230.00 2 3
2 3 964.60 -1 15.50 0 0 0.00 / 230.00 2 3
3 3 1021.96 1 15.25 1728 26 0.26 / 230.02 2 4
4 7 2010.72 38 14.92 2905 1647 1.91 / 231.67 2 6
5 13 1374.64 18 14.96 2128 573 2.48 / 232.24 2 6
6 13 929.76 18 15.01 1573 425 2.91 / 232.67 2 9
7 13 141.20 18 15.21 507 139 3.05 / 232.81 2 10
8 8 0.20 165 15.18 319 799 3.85 / 233.60 2 14
Average= 3.83
(KJ/cycle)

Cycle 59 : GMT 20/ 4/2026 20:55: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.12 34 15.12 470 242 0.24 / 226.19 2 3
2 7 2008.68 38 14.92 2886 1636 1.88 / 227.83 2 8
3 13 1406.40 18 14.95 2182 587 2.47 / 228.41 2 10
4 13 878.16 18 15.02 1504 407 2.87 / 228.82 2 12
5 13 145.48 18 15.19 519 142 3.01 / 228.96 2 9
6 8 0.08 165 15.18 317 794 3.81 / 229.76 2 17
Average= 3.83
(KJ/cycle)

Cycle 58 : GMT 11/ 4/2026 1:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.20 34 15.14 463 238 0.24 / 222.39 2 3
2 7 2004.36 38 14.92 2877 1631 1.87 / 224.02 2 15
3 13 1390.20 18 14.97 2126 573 2.44 / 224.59 2 10
4 13 858.48 18 15.03 1446 391 2.83 / 224.98 2 10
5 13 185.48 18 15.19 577 158 2.99 / 225.14 2 9
6 8 0.16 165 15.18 323 809 3.80 / 225.95 2 11
Average= 3.83
(KJ/cycle)

Cycle 57 : GMT 1/ 4/2026 6:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.84 35 15.13 457 242 0.24 / 218.60 3 3
2 7 2003.28 38 14.93 2872 1629 1.87 / 220.23 2 6
3 13 1398.04 18 14.96 2150 579 2.45 / 220.80 2 7
4 13 904.84 18 15.04 1525 413 2.86 / 221.22 2 9
5 13 135.20 18 15.22 503 138 3.00 / 221.35 2 8
6 8 -0.12 165 15.19 317 795 3.80 / 222.15 2 11
Average= 3.83
(KJ/cycle)

Cycle 56 : GMT 22/ 3/2026 11:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.52 33 15.14 451 225 0.23 / 214.77 2 3
2 10 1005.52 2 15.18 1652 50 0.28 / 214.82 2 5
3 7 2004.12 38 14.93 2883 1636 1.91 / 216.46 2 11
4 13 1364.28 18 14.96 2104 567 2.48 / 217.02 2 9
5 13 833.28 18 15.05 1426 386 2.86 / 217.41 2 9
6 13 155.96 18 15.21 527 144 3.01 / 217.55 2 9
7 8 0.40 165 15.20 319 800 3.81 / 218.35 2 14
Average= 3.83
(KJ/cycle)

Cycle 55 : GMT 12/ 3/2026 16: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.92 35 15.14 466 247 0.25 / 211.00 2 3
2 3 933.32 -1 15.53 0 0 0.00 / 211.00 2 3
3 7 2004.44 38 14.93 2877 1632 1.88 / 212.64 2 11
4 13 1354.08 18 14.98 2092 564 2.44 / 213.20 2 13
5 13 915.76 18 15.03 1550 419 2.86 / 213.62 2 10
6 13 120.56 18 15.23 484 133 3.00 / 213.75 2 8
7 8 -0.12 165 15.20 316 793 3.79 / 214.55 2 13
Average= 3.83
(KJ/cycle)

Cycle 54 : GMT 2/ 3/2026 20:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.16 34 15.13 476 245 0.24 / 207.07 2 3
2 7 2003.76 38 14.92 2878 1632 1.88 / 208.70 2 8
3 13 1395.60 18 14.97 2159 582 2.46 / 209.28 2 9
4 13 907.00 18 15.03 1540 417 2.87 / 209.70 2 11
5 13 207.44 18 15.20 605 166 3.04 / 209.86 2 10
6 13 19.00 18 15.24 355 97 3.14 / 209.96 2 8
7 8 2.72 165 15.19 319 800 3.94 / 210.76 3 18
Average= 3.83
(KJ/cycle)

Cycle 53 : GMT 21/ 2/2026 1:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.00 34 15.14 462 238 0.24 / 203.26 2 3
2 3 1017.24 1 15.23 1695 26 0.26 / 203.28 2 5
3 7 2005.56 38 14.92 2896 1642 1.91 / 204.93 2 7
4 13 1354.60 18 14.96 2092 563 2.47 / 205.49 2 9
5 13 825.84 18 15.05 1428 387 2.86 / 205.88 2 12
6 13 144.40 18 15.21 518 142 3.00 / 206.02 2 9
7 8 0.00 165 15.19 320 802 3.80 / 206.82 3 11
Average= 3.83
(KJ/cycle)

Cycle 52 : GMT 11/ 2/2026 6:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.24 35 15.14 456 242 0.24 / 199.39 2 3
2 7 2007.92 39 14.92 2913 1695 1.94 / 201.08 2 11
3 13 1357.60 18 14.97 2126 573 2.51 / 201.65 2 11
4 13 833.72 18 15.06 1438 390 2.90 / 202.04 2 10
5 13 253.32 18 15.18 669 183 3.08 / 202.23 2 9
6 8 0.32 165 15.20 317 795 3.88 / 203.02 2 12
Average= 3.83
(KJ/cycle)

Cycle 51 : GMT 1/ 2/2026 11:26: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.08 34 15.16 465 240 0.24 / 195.58 2 3
2 7 2005.24 38 14.94 2897 1645 1.88 / 197.22 2 12
3 13 1334.48 18 14.98 2080 561 2.45 / 197.78 2 8
4 13 860.88 18 15.05 1484 402 2.85 / 198.19 2 11
5 13 170.60 18 15.22 561 154 3.00 / 198.34 2 10
6 8 -0.24 165 15.21 320 803 3.80 / 199.14 2 13
Average= 3.83
(KJ/cycle)

Cycle 50 : GMT 22/ 1/2026 16: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.56 34 15.16 462 238 0.24 / 191.80 2 3
2 7 2005.88 38 14.95 2854 1621 1.86 / 193.43 2 7
3 13 1407.44 18 14.98 2164 584 2.44 / 194.01 2 8
4 13 841.72 18 15.07 1450 393 2.84 / 194.40 2 10
5 13 136.72 18 15.24 505 139 2.97 / 194.54 2 8
6 8 0.08 165 15.21 318 798 3.77 / 195.34 2 12
Average= 3.83
(KJ/cycle)

Cycle 49 : GMT 12/ 1/2026 20:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.16 34 15.18 445 230 0.23 / 187.96 2 3
2 3 1030.96 1 15.24 1734 26 0.26 / 187.98 2 5
3 7 2009.08 38 14.94 2904 1649 1.90 / 189.63 2 10
4 13 1345.04 18 14.99 2128 574 2.48 / 190.21 2 10
5 13 869.16 18 15.06 1484 402 2.88 / 190.61 2 9
6 13 171.12 18 15.24 549 151 3.03 / 190.76 2 10
7 8 0.00 165 15.22 321 806 3.84 / 191.57 3 14
Average= 3.83
(KJ/cycle)

Cycle 48 : GMT 3/ 1/2026 1:41: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.60 32 15.18 452 220 0.22 / 184.05 2 3
2 10 1035.72 2 15.20 1745 53 0.27 / 184.11 2 7
3 3 1024.84 1 15.24 1752 27 0.30 / 184.13 2 7
4 7 2008.92 39 14.95 2906 1694 1.99 / 185.83 2 15
5 13 1394.40 18 14.99 2168 585 2.58 / 186.41 2 12
6 13 824.20 18 15.07 1426 387 2.97 / 186.80 2 11
7 13 126.68 18 15.24 478 131 3.10 / 186.93 2 9
8 8 0.08 165 15.22 318 799 3.90 / 187.73 2 13
Average= 3.83
(KJ/cycle)

Cycle 47 : GMT 24/12/2025 6:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.24 17 15.19 472 122 0.12 / 179.77 2 3
2 10 1114.72 6 15.11 1820 165 0.29 / 179.93 2 3
3 10 1170.60 3 15.11 1944 88 0.38 / 180.02 2 5
4 10 1205.20 2 15.10 1984 60 0.43 / 180.08 2 4
5 3 1204.92 6 15.13 1980 180 0.61 / 180.26 2 8
6 3 1031.12 1 15.25 1770 27 0.64 / 180.29 2 4
7 7 2003.76 38 14.94 2874 1632 2.27 / 181.92 2 12
8 13 1356.60 18 14.99 2126 574 2.85 / 182.49 2 7
9 13 832.04 18 15.07 1440 391 3.24 / 182.88 2 11
10 13 145.04 18 15.25 515 141 3.38 / 183.02 2 9
11 8 0.16 165 15.23 322 809 4.19 / 183.83 2 13
Average= 3.83
(KJ/cycle)

Cycle 46 : GMT 14/12/2025 11:10: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.92 35 15.17 466 247 0.25 / 175.71 2 3
2 3 740.08 -5 15.53 0 0 0.00 / 175.71 2 3
3 3 730.80 -5 15.57 0 0 0.00 / 175.71 2 3
4 5 1349.96 10 15.18 2186 332 0.58 / 176.04 2 6
5 7 2010.32 38 14.95 2879 1636 2.21 / 177.68 2 13
6 13 1401.96 18 14.99 2167 585 2.80 / 178.26 2 8
7 13 859.00 18 15.07 1466 398 3.20 / 178.66 2 9
8 13 221.28 18 15.22 635 174 3.37 / 178.83 2 10
9 8 -0.04 165 15.23 324 814 4.19 / 179.65 2 15
Average= 3.82
(KJ/cycle)

Cycle 45 : GMT 4/12/2025 16:18:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.40 34 15.20 465 240 0.24 / 171.88 2 3
2 3 1020.96 1 15.25 1714 26 0.27 / 171.91 2 4
3 7 2003.92 38 14.94 2907 1650 1.92 / 173.56 2 7
4 13 1345.88 18 14.99 2112 570 2.49 / 174.13 2 11
5 13 797.40 18 15.09 1383 376 2.86 / 174.50 2 10
6 13 162.40 18 15.25 546 150 3.01 / 174.65 2 10
7 8 0.20 165 15.23 321 807 3.82 / 175.46 2 12
Average= 3.81
(KJ/cycle)

Cycle 44 : GMT 24/11/2025 21: 6: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.84 35 15.19 456 242 0.24 / 168.03 2 3
2 3 965.64 -1 15.55 0 0 0.00 / 168.03 2 3
3 3 1020.16 1 15.30 1730 26 0.27 / 168.06 2 5
4 7 2011.04 38 14.96 2863 1628 1.90 / 169.69 2 9
5 13 1435.60 18 14.99 2217 598 2.49 / 170.29 2 10
6 13 891.12 18 15.08 1511 410 2.90 / 170.70 2 11
7 13 164.48 18 15.24 547 150 3.05 / 170.85 2 9
8 8 -0.12 165 15.24 316 795 3.85 / 171.64 2 12
Average= 3.81
(KJ/cycle)

Cycle 43 : GMT 15/11/2025 1:48:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.92 35 15.19 467 248 0.25 / 164.24 2 3
2 7 2010.28 38 14.96 2873 1633 1.88 / 165.88 2 7
3 13 1360.28 18 15.01 2097 567 2.45 / 166.44 2 7
4 13 883.80 18 15.08 1508 409 2.86 / 166.85 2 12
5 13 138.68 18 15.25 506 139 3.00 / 166.99 2 9
6 8 0.52 165 15.25 318 800 3.80 / 167.79 2 16
Average= 3.81
(KJ/cycle)

Cycle 42 : GMT 5/11/2025 6:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.64 35 15.19 470 250 0.25 / 160.44 2 3
2 7 2008.80 38 14.96 2902 1650 1.90 / 162.09 2 8
3 13 1397.96 18 15.01 2162 584 2.48 / 162.68 2 9
4 13 824.68 18 15.09 1415 384 2.87 / 163.06 2 11
5 13 109.76 18 15.27 461 127 2.99 / 163.19 2 8
6 8 -0.08 165 15.25 321 808 3.80 / 164.00 2 13
Average= 3.81
(KJ/cycle)

Cycle 41 : GMT 26/10/2025 11:21: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.24 35 15.19 462 246 0.25 / 156.58 2 3
2 7 2008.48 39 14.94 2913 1697 1.94 / 158.27 2 10
3 13 1327.96 18 15.01 2073 560 2.50 / 158.83 2 9
4 13 850.04 18 15.09 1452 394 2.90 / 159.23 2 10
5 13 160.00 18 15.26 543 149 3.05 / 159.38 2 10
6 8 0.08 165 15.25 324 815 3.86 / 160.19 3 13
Average= 3.81
(KJ/cycle)

Cycle 40 : GMT 16/10/2025 16: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.68 35 15.19 466 248 0.25 / 152.73 2 3
2 7 2003.48 38 14.94 2891 1641 1.89 / 154.37 2 12
3 13 1359.08 18 15.01 2097 567 2.46 / 154.93 2 6
4 13 890.72 18 15.08 1519 412 2.87 / 155.35 2 12
5 13 240.76 18 15.23 655 180 3.05 / 155.53 2 10
6 8 -0.20 165 15.24 320 805 3.85 / 156.33 3 14
Average= 3.81
(KJ/cycle)

Cycle 39 : GMT 6/10/2025 21: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.80 35 15.21 447 238 0.24 / 148.85 2 3
2 7 2011.00 38 14.95 2889 1641 1.88 / 150.49 2 10
3 13 1487.16 18 14.99 2272 613 2.49 / 151.11 2 11
4 13 899.88 18 15.08 1533 416 2.91 / 151.52 2 9
5 13 168.92 18 15.25 543 149 3.06 / 151.67 2 9
6 8 0.16 165 15.25 321 808 3.87 / 152.48 2 15
Average= 3.81
(KJ/cycle)

Cycle 38 : GMT 27/ 9/2025 1:52:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.52 35 15.20 474 252 0.25 / 145.04 2 3
2 7 2010.04 39 14.95 2891 1686 1.94 / 146.72 2 10
3 13 1369.96 18 15.01 2111 570 2.51 / 147.29 2 8
4 13 837.24 18 15.10 1438 391 2.90 / 147.68 2 11
5 13 148.32 18 15.26 525 144 3.04 / 147.83 2 9
6 8 0.32 165 15.25 313 788 3.83 / 148.61 2 13
Average= 3.81
(KJ/cycle)

Cycle 37 : GMT 17/ 9/2025 6:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.12 35 15.20 460 245 0.24 / 141.22 2 3
2 7 2004.12 38 14.97 2855 1624 1.87 / 142.85 2 7
3 13 1450.76 18 15.00 2234 603 2.47 / 143.45 2 10
4 13 780.00 18 15.13 1359 370 2.84 / 143.82 2 10
5 13 201.88 18 15.25 592 163 3.00 / 143.98 2 9
6 8 -0.12 165 15.26 318 801 3.81 / 144.78 2 17
Average= 3.81
(KJ/cycle)

Cycle 36 : GMT 7/ 9/2025 11:19:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.12 35 15.21 473 252 0.25 / 137.28 2 3
2 7 2004.36 38 14.95 2901 1648 1.90 / 138.93 2 9
3 13 1351.00 18 15.01 2082 563 2.46 / 139.49 2 7
4 13 870.88 18 15.09 1488 404 2.87 / 139.89 2 9
5 13 143.60 18 15.26 512 141 3.01 / 140.04 2 9
6 8 0.08 165 15.25 317 798 3.80 / 140.83 2 9
7 14 0.08 30 15.23 317 145 3.95 / 140.98 3 14
Average= 3.81
(KJ/cycle)

Cycle 35 : GMT 28/ 8/2025 15:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.80 35 15.21 463 246 0.25 / 133.42 2 3
2 7 2010.08 38 14.96 2901 1649 1.90 / 135.07 2 12
3 13 1446.60 18 14.99 2223 600 2.50 / 135.67 2 9
4 13 817.56 18 15.11 1403 382 2.88 / 136.05 2 11
5 13 225.52 18 15.24 631 173 3.05 / 136.23 2 9
6 8 0.00 165 15.26 318 801 3.85 / 137.03 3 16
Average= 3.81
(KJ/cycle)

Cycle 34 : GMT 18/ 8/2025 20:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.16 35 15.19 472 251 0.25 / 129.63 2 3
2 7 2003.36 38 14.94 2893 1642 1.89 / 131.27 2 9
3 13 1393.80 18 15.01 2146 580 2.47 / 131.85 2 11
4 13 866.20 18 15.10 1478 402 2.87 / 132.25 2 8
5 13 47.56 18 15.31 379 104 2.98 / 132.36 2 7
6 8 0.08 165 15.27 326 821 3.80 / 133.18 2 13
Average= 3.81
(KJ/cycle)

Cycle 33 : GMT 9/ 8/2025 1:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.88 35 15.21 478 254 0.25 / 125.78 2 3
2 7 2006.12 38 14.94 2888 1640 1.89 / 127.41 2 8
3 13 1396.52 18 15.02 2138 578 2.47 / 127.99 2 9
4 13 902.28 18 15.09 1507 409 2.88 / 128.40 2 10
5 13 200.36 18 15.25 596 164 3.05 / 128.57 2 9
6 8 0.20 165 15.26 322 811 3.86 / 129.38 2 14
Average= 3.81
(KJ/cycle)

Cycle 32 : GMT 30/ 7/2025 6:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.80 35 15.23 458 244 0.24 / 121.89 2 3
2 7 2003.88 38 14.98 2882 1641 1.88 / 123.53 2 12
3 13 1392.04 18 15.03 2154 583 2.47 / 124.11 2 9
4 13 823.24 18 15.12 1423 387 2.85 / 124.50 2 12
5 13 319.16 18 15.24 752 206 3.06 / 124.71 2 10
6 8 0.24 165 15.27 323 814 3.87 / 125.52 3 13
Average= 3.80
(KJ/cycle)

Cycle 31 : GMT 20/ 7/2025 11:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.60 35 15.22 474 252 0.25 / 118.04 2 3
2 7 2004.60 38 14.97 2891 1645 1.90 / 119.68 2 13
3 13 1401.00 18 15.03 2155 583 2.48 / 120.26 2 6
4 13 913.76 18 15.10 1542 419 2.90 / 120.68 2 8
5 13 151.60 18 15.28 533 147 3.05 / 120.83 2 9
6 8 0.00 165 15.27 324 816 3.86 / 121.65 2 13
Average= 3.80
(KJ/cycle)

Cycle 30 : GMT 10/ 7/2025 16:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.04 35 15.22 460 245 0.25 / 114.17 2 3
2 7 2004.72 38 14.99 2889 1646 1.89 / 115.81 2 14
3 13 1439.92 18 15.03 2207 597 2.49 / 116.41 2 11
4 13 939.08 18 15.11 1578 429 2.92 / 116.84 2 13
5 13 131.40 18 15.30 496 137 3.05 / 116.98 2 9
6 8 0.12 165 15.28 320 807 3.86 / 117.78 3 14
Average= 3.80
(KJ/cycle)

Cycle 29 : GMT 30/ 6/2025 21:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.40 34 15.24 448 232 0.23 / 110.34 3 3
2 3 1022.32 1 15.29 1746 27 0.26 / 110.37 2 7
3 7 2003.16 38 14.97 2884 1641 1.90 / 112.01 2 5
4 13 1366.84 18 15.03 2102 569 2.47 / 112.58 2 10
5 13 855.56 18 15.12 1443 393 2.86 / 112.97 2 9
6 13 143.68 18 15.28 519 143 3.00 / 113.11 2 8
7 8 0.28 165 15.27 321 809 3.81 / 113.92 2 17
Average= 3.80
(KJ/cycle)

Cycle 28 : GMT 21/ 6/2025 2: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.44 34 15.23 471 244 0.24 / 106.55 2 3
2 7 2005.36 38 14.98 2894 1647 1.89 / 108.19 2 5
3 13 1404.32 18 15.05 2155 584 2.48 / 108.78 2 9
4 13 819.84 18 15.13 1420 387 2.86 / 109.16 2 9
5 13 145.92 18 15.30 517 142 3.00 / 109.31 2 9
6 8 0.24 165 15.29 319 805 3.81 / 110.11 3 14
Average= 3.80
(KJ/cycle)

Cycle 27 : GMT 11/ 6/2025 6:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.44 34 15.24 479 248 0.25 / 102.75 2 3
2 7 2004.44 38 14.98 2873 1635 1.88 / 104.38 2 7
3 13 1359.16 18 15.05 2103 570 2.45 / 104.95 2 10
4 13 843.52 18 15.13 1462 398 2.85 / 105.35 2 9
5 13 155.48 18 15.28 530 146 3.00 / 105.50 2 9
6 8 0.20 165 15.28 319 804 3.80 / 106.30 3 12
Average= 3.80
(KJ/cycle)

Cycle 26 : GMT 1/ 6/2025 11:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.76 35 15.24 477 254 0.25 / 98.89 3 3
2 7 2003.04 38 14.98 2886 1643 1.90 / 100.53 2 5
3 13 1389.76 18 15.05 2138 579 2.48 / 101.11 2 9
4 13 903.00 18 15.13 1540 419 2.90 / 101.53 2 11
5 13 161.20 18 15.29 545 150 3.05 / 101.68 2 9
6 8 0.08 165 15.29 324 817 3.86 / 102.50 2 14
Average= 3.80
(KJ/cycle)

Cycle 25 : GMT 22/ 5/2025 16:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.04 35 15.23 470 251 0.25 / 95.05 2 3
2 7 2004.40 38 15.00 2888 1646 1.90 / 96.70 2 16
3 13 1450.92 18 15.05 2223 602 2.50 / 97.30 2 9
4 13 814.28 18 15.15 1408 384 2.88 / 97.68 2 12
5 13 125.12 18 15.31 491 135 3.02 / 97.82 2 8
6 8 0.04 165 15.29 325 820 3.84 / 98.64 2 13
Average= 3.79
(KJ/cycle)

Cycle 24 : GMT 12/ 5/2025 21:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.16 34 15.23 471 244 0.24 / 91.25 2 3
2 7 2010.44 38 14.98 2906 1654 1.90 / 92.90 2 9
3 13 1353.56 18 15.05 2107 571 2.47 / 93.47 2 6
4 13 784.44 18 15.15 1386 378 2.85 / 93.85 2 9
5 13 135.92 18 15.29 508 140 2.99 / 93.99 2 9
6 8 0.12 165 15.29 320 807 3.79 / 94.80 3 13
Average= 3.79
(KJ/cycle)

Cycle 23 : GMT 3/ 5/2025 2: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.72 34 15.23 468 242 0.24 / 87.40 2 3
2 7 2010.96 38 14.99 2902 1653 1.90 / 89.05 2 14
3 13 1447.92 18 15.03 2247 608 2.50 / 89.66 2 9
4 13 811.24 18 15.15 1408 384 2.89 / 90.04 2 8
5 13 135.00 18 15.29 506 139 3.03 / 90.18 2 8
6 8 0.00 165 15.27 326 821 3.85 / 91.01 2 15
Average= 3.79
(KJ/cycle)

Cycle 22 : GMT 23/ 4/2025 6:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.24 34 15.22 480 248 0.25 / 83.59 2 3
2 7 2008.60 38 14.98 2881 1640 1.89 / 85.23 2 6
3 13 1386.84 18 15.04 2147 581 2.47 / 85.81 2 12
4 13 771.12 18 15.14 1355 369 2.84 / 86.18 2 9
5 13 177.00 18 15.28 563 155 2.99 / 86.33 2 9
6 8 0.36 165 15.28 328 827 3.82 / 87.16 3 13
Average= 3.79
(KJ/cycle)

Cycle 21 : GMT 13/ 4/2025 11:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.52 34 15.22 456 236 0.24 / 79.72 2 3
2 3 1021.56 1 15.30 1675 26 0.26 / 79.75 2 3
3 7 2003.08 38 14.97 2893 1646 1.91 / 81.40 2 7
4 13 1396.44 18 15.05 2170 588 2.50 / 81.98 2 7
5 13 861.08 18 15.14 1456 397 2.89 / 82.38 2 9
6 13 118.88 18 15.31 486 134 3.03 / 82.51 2 8
7 8 0.00 165 15.29 326 822 3.85 / 83.34 2 12
Average= 3.79
(KJ/cycle)

Cycle 20 : GMT 3/ 4/2025 16:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.96 34 15.24 453 235 0.23 / 75.67 2 3
2 7 2008.72 38 14.96 2890 1643 1.88 / 77.32 2 5
3 13 1353.92 18 15.05 2088 566 2.44 / 77.88 2 10
4 13 915.24 18 15.12 1541 419 2.86 / 78.30 2 10
5 13 107.64 18 15.31 470 130 2.99 / 78.43 2 8
6 13 25.20 18 15.31 365 101 3.09 / 78.53 2 9
7 8 0.76 165 15.28 322 812 3.90 / 79.34 2 11
8 14 0.76 30 15.25 316 145 4.05 / 79.49 5 13
Average= 3.79
(KJ/cycle)

Cycle 19 : GMT 24/ 3/2025 21: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.32 34 15.24 467 242 0.24 / 71.68 2 3
2 3 1020.40 1 15.30 1680 26 0.27 / 71.70 2 6
3 7 2005.24 38 15.00 2896 1651 1.92 / 73.36 2 7
4 13 1388.12 18 15.06 2153 584 2.50 / 73.94 2 6
5 13 854.36 18 15.14 1484 404 2.91 / 74.34 2 10
6 13 117.52 18 15.33 481 133 3.04 / 74.48 2 8
7 8 -0.04 165 15.30 324 818 3.86 / 75.29 2 15
8 14 -0.04 30 15.26 318 146 4.00 / 75.44 2 16
Average= 3.77
(KJ/cycle)

Cycle 18 : GMT 15/ 3/2025 1:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.32 33 15.24 468 235 0.24 / 67.84 2 3
2 3 1021.40 1 15.29 1727 26 0.26 / 67.86 2 4
3 7 2003.76 38 15.00 2890 1647 1.91 / 69.51 2 10
4 13 1349.48 18 15.07 2102 570 2.48 / 70.08 2 8
5 13 857.92 18 15.14 1471 401 2.88 / 70.48 2 10
6 13 119.96 18 15.33 494 136 3.02 / 70.62 2 9
7 8 0.12 165 15.30 325 820 3.84 / 71.44 2 14
Average= 3.76
(KJ/cycle)

Cycle 17 : GMT 5/ 3/2025 6:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.04 32 15.24 469 229 0.23 / 64.01 2 3
2 3 1047.72 1 15.29 1759 27 0.26 / 64.04 2 5
3 7 2006.60 38 15.00 2894 1650 1.91 / 65.69 2 10
4 13 1397.88 18 15.07 2115 574 2.48 / 66.26 2 11
5 13 850.04 18 15.15 1461 398 2.88 / 66.66 2 10
6 13 73.32 18 15.32 434 120 3.00 / 66.78 2 9
7 8 0.12 165 15.29 326 822 3.82 / 67.60 2 16
Average= 3.76
(KJ/cycle)

Cycle 16 : GMT 23/ 2/2025 11:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.84 32 15.25 469 229 0.23 / 60.13 2 3
2 3 1019.40 1 15.33 1676 26 0.25 / 60.15 2 3
3 7 2003.40 38 15.01 2883 1644 1.90 / 61.80 2 11
4 13 1496.32 18 15.05 2314 627 2.53 / 62.43 2 12
5 13 849.12 18 15.14 1490 406 2.93 / 62.83 2 11
6 13 132.44 18 15.32 501 138 3.07 / 62.97 2 8
7 8 0.00 165 15.30 321 810 3.88 / 63.78 2 15
Average= 3.75
(KJ/cycle)

Cycle 15 : GMT 13/ 2/2025 16:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.52 32 15.25 474 231 0.23 / 56.25 2 3
2 7 2003.12 38 15.02 2845 1624 1.86 / 57.87 2 10
3 13 1445.52 18 15.05 2230 604 2.46 / 58.48 2 7
4 13 915.60 18 15.12 1567 426 2.89 / 58.91 2 10
5 13 212.52 18 15.29 625 172 3.06 / 59.08 2 11
6 8 0.00 165 15.29 326 822 3.88 / 59.90 2 13
Average= 3.74
(KJ/cycle)

Cycle 14 : GMT 3/ 2/2025 21: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.08 32 15.26 483 236 0.24 / 52.36 2 3
2 7 2004.84 38 15.03 2879 1644 1.88 / 54.00 2 5
3 13 1462.04 18 15.06 2252 610 2.49 / 54.61 2 9
4 13 921.20 18 15.14 1547 422 2.91 / 55.03 2 11
5 13 182.08 18 15.33 570 157 3.07 / 55.19 2 9
6 8 0.00 165 15.32 328 829 3.90 / 56.02 2 17
Average= 3.73
(KJ/cycle)

Cycle 13 : GMT 25/ 1/2025 1:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.68 32 15.27 491 240 0.24 / 48.53 2 3
2 7 2003.00 38 15.02 2862 1634 1.87 / 50.17 2 6
3 13 1393.08 18 15.08 2144 582 2.46 / 50.75 2 9
4 13 870.96 18 15.16 1478 403 2.86 / 51.15 2 10
5 13 95.20 18 15.35 455 126 2.98 / 51.28 2 8
6 8 0.12 165 15.32 333 842 3.83 / 52.12 2 16
Average= 3.72
(KJ/cycle)

Cycle 12 : GMT 15/ 1/2025 6:34: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.52 32 15.27 489 239 0.24 / 44.71 2 3
2 7 2003.12 38 15.01 2889 1648 1.89 / 46.36 2 9
3 13 1438.08 18 15.07 2211 600 2.49 / 46.96 2 9
4 13 806.24 18 15.18 1401 383 2.87 / 47.34 2 10
5 13 93.84 18 15.36 455 126 3.00 / 47.47 2 8
6 8 0.00 165 15.32 327 827 3.82 / 48.29 2 13
Average= 3.71
(KJ/cycle)

Cycle 11 : GMT 5/ 1/2025 11:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.40 32 15.28 480 235 0.23 / 40.85 2 3
2 3 1019.20 1 15.32 1734 27 0.26 / 40.88 2 7
3 7 2003.92 39 15.01 2863 1676 1.94 / 42.55 2 12
4 13 1355.80 18 15.09 2078 564 2.50 / 43.12 2 9
5 13 875.36 18 15.17 1455 397 2.90 / 43.52 2 9
6 13 73.76 18 15.35 428 118 3.02 / 43.63 2 8
7 8 0.40 165 15.32 332 839 3.86 / 44.47 2 14
Average= 3.71
(KJ/cycle)

Cycle 10 : GMT 26/12/2024 16: 3:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.96 33 15.27 476 240 0.24 / 37.05 2 3
2 3 936.24 -1 15.62 0 0 0.00 / 37.05 2 3
3 7 2003.00 39 15.01 2887 1690 1.93 / 38.74 2 11
4 13 1342.92 18 15.09 2072 563 2.49 / 39.30 2 8
5 13 814.08 18 15.17 1421 388 2.88 / 39.69 2 9
6 13 46.92 18 15.35 397 110 2.99 / 39.80 2 9
7 8 0.04 165 15.31 325 821 3.81 / 40.62 2 14
Average= 3.69
(KJ/cycle)

Cycle 9 : GMT 16/12/2024 20:37: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.96 32 15.28 466 228 0.23 / 33.20 2 3
2 10 1026.80 2 15.31 1738 53 0.28 / 33.26 2 3
3 7 2007.60 38 15.01 2889 1648 1.93 / 34.90 2 7
4 13 1333.24 18 15.10 2068 562 2.49 / 35.47 2 9
5 13 843.76 18 15.17 1449 396 2.89 / 35.86 2 10
6 13 64.88 18 15.35 413 114 3.00 / 35.98 2 8
7 8 0.24 165 15.32 328 829 3.83 / 36.81 2 12
Average= 3.68
(KJ/cycle)

Cycle 8 : GMT 7/12/2024 1:23:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.20 30 15.29 468 215 0.21 / 28.64 2 3
2 10 1044.16 2 15.27 1761 54 0.27 / 28.69 2 6
3 3 1018.72 1 15.36 1734 27 0.30 / 28.72 2 4
4 7 2010.76 74 14.87 2887 3177 3.47 / 31.90 2 11
5 13 474.76 18 15.26 960 264 3.74 / 32.16 2 10
6 8 0.12 165 15.34 322 815 4.55 / 32.98 2 14
Average= 3.66
(KJ/cycle)

Cycle 7 : GMT 27/11/2024 4:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.16 32 15.27 466 228 0.23 / 24.43 2 3
2 7 1808.12 75 14.95 2640 2960 3.19 / 27.39 2 12
3 13 288.24 18 15.30 712 196 3.38 / 27.59 2 9
4 8 0.08 165 15.31 332 839 4.22 / 28.42 3 14
Average= 3.55
(KJ/cycle)

Cycle 6 : GMT 26/11/2024 3:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.52 32 15.27 466 228 0.23 / 20.21 2 3
2 7 1815.68 74 14.95 2650 2932 3.16 / 23.14 2 12
3 13 392.52 18 15.28 849 234 3.39 / 23.38 2 9
4 8 0.04 165 15.32 327 827 4.22 / 24.20 2 11
Average= 3.46
(KJ/cycle)

Cycle 5 : GMT 25/11/2024 2:55: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.28 33 15.29 467 236 0.24 / 15.99 2 3
2 3 951.96 -1 15.66 0 0 0.00 / 15.99 2 3
3 7 1816.32 74 14.94 2657 2937 3.17 / 18.93 2 11
4 13 348.56 18 15.29 795 219 3.39 / 19.15 2 9
5 8 -0.08 165 15.33 329 832 4.22 / 19.98 2 18
Average= 3.33
(KJ/cycle)

Cycle 4 : GMT 24/11/2024 2: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.16 33 15.28 460 232 0.23 / 12.23 2 3
2 7 1512.92 74 15.07 2282 2545 2.78 / 14.77 2 9
3 13 158.24 18 15.35 539 149 2.93 / 14.92 2 8
4 8 0.08 165 15.34 331 838 3.76 / 15.76 2 18
Average= 3.15
(KJ/cycle)

Cycle 3 : GMT 23/11/2024 2:41: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.32 31 15.27 460 218 0.22 / 8.38 2 3
2 10 1004.04 2 15.29 1701 52 0.27 / 8.44 2 3
3 7 1508.92 75 15.07 2268 2563 2.83 / 11.00 2 8
4 13 177.44 18 15.34 571 158 2.99 / 11.16 2 9
5 8 0.00 165 15.33 331 837 3.83 / 12.00 2 15
Average= 3.00
(KJ/cycle)

Cycle 2 : GMT 22/11/2024 3:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.52 32 15.33 459 225 0.23 / 4.66 2 3
2 3 961.72 -1 15.67 0 0 0.00 / 4.66 2 3
3 7 1507.48 74 15.07 2256 2516 2.74 / 7.18 2 9
4 13 251.72 18 15.33 649 179 2.92 / 7.35 2 8
5 8 -0.04 165 15.34 321 812 3.73 / 8.17 2 16
Average= 2.72
(KJ/cycle)

Cycle 1 : GMT 21/11/2024 4: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.32 27 15.49 446 187 0.19 / 1.82 3 3
2 3 1046.04 1 15.39 1751 27 0.21 / 1.84 2 6
3 7 996.60 74 15.23 1594 1796 2.01 / 3.64 2 12
4 8 -0.12 165 15.39 313 795 2.80 / 4.43 2 13
Average= 2.22
(KJ/cycle)

Cycle 0 : GMT 20/11/2024 17:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 122.48 27 15.62 415 175 0.18 / 0.18 3 3
2 7 137.24 74 15.59 429 495 0.67 / 0.67 3 4
3 8 0.72 240 15.56 257 960 1.63 / 1.63 3 23
Average= 1.63
(KJ/cycle)