SIO Argo Site:
Pump Diagnostics







Serial= 3308 - WMO= 5907124


Cycle 64 : GMT 15/ 7/2026 4:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.96 31 15.07 475 222 0.22 / 236.41 2 4
2 7 2004.56 38 14.86 2795 1578 1.80 / 237.99 2 6
3 13 1309.28 18 14.90 1982 532 2.33 / 238.52 2 6
4 13 754.76 18 14.98 1303 351 2.68 / 238.87 2 8
5 13 162.24 18 15.12 539 147 2.83 / 239.02 2 9
6 8 0.12 165 15.11 310 773 3.60 / 239.79 2 15
7 14 0.12 30 15.08 310 140 3.74 / 239.93 2 16
Average= 3.69
(KJ/cycle)

Cycle 63 : GMT 5/ 7/2026 9: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.68 31 15.06 479 224 0.22 / 232.74 2 4
2 7 2005.28 38 14.86 2791 1576 1.80 / 234.32 2 5
3 13 1397.48 18 14.89 2092 561 2.36 / 234.88 2 7
4 13 856.68 18 14.97 1425 384 2.74 / 235.26 2 8
5 13 162.56 18 15.12 542 148 2.89 / 235.41 2 9
6 8 -0.08 165 15.12 313 781 3.67 / 236.19 2 13
Average= 3.69
(KJ/cycle)

Cycle 62 : GMT 25/ 6/2026 13:52: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.96 31 15.08 479 224 0.22 / 229.11 2 4
2 3 989.60 -1 15.44 0 0 0.00 / 229.11 2 4
3 7 2004.60 38 14.85 2788 1573 1.80 / 230.68 2 5
4 13 1305.68 18 14.91 1974 530 2.33 / 231.21 2 8
5 13 787.12 18 14.98 1338 361 2.69 / 231.57 2 9
6 13 188.76 18 15.13 588 160 2.85 / 231.73 2 8
7 8 0.04 165 15.13 315 786 3.63 / 232.52 2 14
Average= 3.69
(KJ/cycle)

Cycle 61 : GMT 15/ 6/2026 18:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.16 32 15.07 487 235 0.23 / 225.43 3 5
2 3 977.80 -2 15.44 0 0 0.00 / 225.43 3 5
3 3 1019.56 1 15.19 1667 25 0.26 / 225.45 2 5
4 7 2004.08 38 14.87 2795 1579 1.84 / 227.03 2 6
5 13 1336.64 18 14.92 2017 542 2.38 / 227.57 2 8
6 13 857.80 18 14.97 1425 384 2.77 / 227.96 2 10
7 13 164.40 18 15.14 538 147 2.91 / 228.10 2 8
8 8 0.20 165 15.13 312 779 3.69 / 228.88 2 17
Average= 3.69
(KJ/cycle)

Cycle 60 : GMT 5/ 6/2026 23:35:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.72 32 15.07 484 233 0.23 / 221.74 2 4
2 3 979.60 -2 15.45 0 0 0.00 / 221.74 2 4
3 3 1019.76 1 15.17 1663 25 0.26 / 221.77 2 5
4 7 2004.92 38 14.87 2793 1578 1.84 / 223.35 2 7
5 13 1335.72 18 14.91 2018 542 2.38 / 223.89 2 8
6 13 809.68 18 14.99 1372 370 2.75 / 224.26 2 8
7 13 163.24 18 15.15 541 148 2.90 / 224.41 2 8
8 8 -0.08 165 15.13 315 786 3.68 / 225.19 2 17
Average= 3.69
(KJ/cycle)

Cycle 59 : GMT 27/ 5/2026 4:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.28 32 15.07 471 227 0.23 / 218.03 2 4
2 3 961.36 -3 15.44 0 0 0.00 / 218.03 2 4
3 3 1018.36 1 15.19 1662 25 0.25 / 218.06 2 4
4 7 2004.08 38 14.87 2785 1574 1.83 / 219.63 2 5
5 13 1384.80 18 14.91 2072 556 2.38 / 220.19 2 7
6 13 853.00 18 14.98 1424 384 2.77 / 220.57 2 8
7 13 197.08 18 15.13 591 161 2.93 / 220.73 2 8
8 8 0.32 165 15.13 312 779 3.71 / 221.51 2 16
Average= 3.69
(KJ/cycle)

Cycle 58 : GMT 17/ 5/2026 9:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.44 33 15.06 477 237 0.24 / 214.33 3 4
2 3 919.36 -6 15.44 0 0 0.00 / 214.33 3 4
3 3 1029.12 1 15.17 1683 26 0.26 / 214.35 2 5
4 7 2009.52 38 14.87 2795 1579 1.84 / 215.93 2 6
5 13 1313.16 18 14.92 1989 534 2.38 / 216.47 2 7
6 13 882.28 18 14.97 1461 394 2.77 / 216.86 2 9
7 13 189.12 18 15.13 580 158 2.93 / 217.02 2 9
8 8 0.24 165 15.13 315 786 3.71 / 217.80 2 12
Average= 3.69
(KJ/cycle)

Cycle 57 : GMT 7/ 5/2026 14:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.96 35 15.08 471 249 0.25 / 210.62 3 4
2 3 866.88 -10 15.45 0 0 0.00 / 210.62 3 4
3 3 1061.92 2 15.17 1726 52 0.30 / 210.67 2 5
4 7 2005.48 38 14.88 2766 1564 1.86 / 212.24 2 5
5 13 1357.60 18 14.92 2036 547 2.41 / 212.78 2 8
6 13 825.04 18 14.99 1389 375 2.79 / 213.16 2 9
7 13 177.44 18 15.14 567 155 2.94 / 213.31 2 9
8 8 -0.20 165 15.13 312 779 3.72 / 214.09 2 18
Average= 3.69
(KJ/cycle)

Cycle 56 : GMT 27/ 4/2026 19: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.60 31 15.10 458 214 0.21 / 206.68 3 3
2 3 768.56 -18 15.45 0 0 0.00 / 206.68 3 3
3 3 1299.00 8 15.04 2064 248 0.46 / 206.93 2 5
4 7 2004.96 38 14.88 2787 1576 2.04 / 208.51 2 5
5 13 1374.36 18 14.92 2059 553 2.59 / 209.06 2 7
6 13 792.76 18 15.00 1353 365 2.96 / 209.43 2 8
7 13 197.88 18 15.14 595 162 3.12 / 209.59 2 9
8 8 0.04 165 15.13 313 781 3.90 / 210.37 2 15
Average= 3.69
(KJ/cycle)

Cycle 55 : GMT 18/ 4/2026 0: 5: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.20 31 15.09 470 220 0.22 / 201.84 3 3
2 7 2008.36 38 14.88 2782 1573 1.79 / 203.42 2 5
3 13 1337.28 18 14.93 2016 542 2.33 / 203.96 2 6
4 13 1080.92 18 14.93 1708 459 2.79 / 204.42 2 8
5 13 1056.20 18 14.91 1676 450 3.24 / 204.87 2 8
6 13 1024.60 18 14.86 1638 438 3.68 / 205.30 2 10
7 13 853.40 18 14.90 1425 382 4.06 / 205.69 2 10
8 8 0.36 165 15.12 314 783 4.85 / 206.47 2 13
Average= 3.69
(KJ/cycle)

Cycle 54 : GMT 8/ 4/2026 4:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.80 31 15.08 484 226 0.23 / 198.18 3 3
2 7 2002.68 38 14.88 2784 1574 1.80 / 199.75 2 6
3 13 1379.40 18 14.93 2069 556 2.36 / 200.31 2 7
4 13 808.16 18 15.01 1374 371 2.73 / 200.68 2 8
5 13 205.44 18 15.14 600 164 2.89 / 200.84 2 9
6 8 0.12 165 15.15 313 782 3.67 / 201.62 2 16
Average= 3.67
(KJ/cycle)

Cycle 53 : GMT 29/ 3/2026 9:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.28 31 15.09 479 224 0.22 / 194.34 2 3
2 7 2003.84 38 14.88 2788 1576 1.80 / 195.91 2 6
3 13 1385.36 18 14.92 2071 556 2.36 / 196.47 2 7
4 13 893.80 18 14.99 1470 397 2.75 / 196.87 2 8
5 13 192.64 18 15.15 582 159 2.91 / 197.03 2 8
6 8 0.40 165 15.14 313 782 3.69 / 197.81 2 12
7 14 0.40 30 15.11 311 141 3.83 / 197.95 3 17
Average= 3.67
(KJ/cycle)

Cycle 52 : GMT 19/ 3/2026 14:41: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.96 31 15.08 474 222 0.22 / 190.67 3 3
2 7 2005.60 38 14.88 2782 1573 1.79 / 192.25 2 6
3 13 1342.80 18 14.93 2021 543 2.34 / 192.79 2 7
4 13 849.56 18 14.99 1413 381 2.72 / 193.17 2 9
5 13 198.48 18 15.16 587 160 2.88 / 193.33 2 8
6 8 0.20 165 15.14 313 782 3.66 / 194.11 2 15
Average= 3.66
(KJ/cycle)

Cycle 51 : GMT 9/ 3/2026 19:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.76 31 15.10 472 221 0.22 / 186.98 3 3
2 7 2005.64 38 14.88 2767 1565 1.79 / 188.54 2 9
3 13 1340.40 18 14.93 1998 537 2.32 / 189.08 2 7
4 13 807.96 18 15.01 1365 369 2.69 / 189.45 2 9
5 13 168.28 18 15.17 549 150 2.84 / 189.60 2 9
6 13 13.96 18 15.18 329 90 2.93 / 189.69 2 9
7 8 0.16 165 15.13 307 766 3.70 / 190.45 2 15
Average= 3.66
(KJ/cycle)

Cycle 50 : GMT 28/ 2/2026 0:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.24 31 15.09 477 223 0.22 / 183.24 2 3
2 7 2008.48 38 14.88 2797 1582 1.80 / 184.82 2 4
3 13 1344.64 18 14.94 2012 541 2.35 / 185.36 2 7
4 13 816.32 18 15.01 1377 372 2.72 / 185.74 2 9
5 13 173.96 18 15.16 551 150 2.87 / 185.89 2 9
6 13 16.72 18 15.19 336 92 2.96 / 185.98 2 9
7 8 0.08 165 15.15 311 777 3.74 / 186.76 2 15
Average= 3.66
(KJ/cycle)

Cycle 49 : GMT 18/ 2/2026 5:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.28 31 15.09 464 217 0.22 / 179.51 2 3
2 7 2004.76 38 14.88 2786 1575 1.79 / 181.08 2 6
3 13 1334.12 18 14.95 2010 541 2.33 / 181.62 2 8
4 13 803.08 18 15.01 1364 369 2.70 / 181.99 2 9
5 13 195.32 18 15.17 581 159 2.86 / 182.15 2 9
6 13 18.92 18 15.20 335 92 2.95 / 182.24 2 8
7 8 0.08 165 15.14 311 777 3.73 / 183.02 2 12
Average= 3.66
(KJ/cycle)

Cycle 48 : GMT 8/ 2/2026 10:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.92 31 15.11 465 218 0.22 / 175.75 2 3
2 7 2005.04 39 14.89 2772 1610 1.83 / 177.36 2 5
3 13 1337.64 18 14.95 1996 537 2.36 / 177.90 2 7
4 13 841.00 18 15.01 1404 379 2.74 / 178.27 2 8
5 13 153.68 18 15.18 527 144 2.89 / 178.42 2 9
6 13 21.56 18 15.20 340 93 2.98 / 178.51 2 9
7 8 0.28 165 15.15 311 777 3.76 / 179.29 2 16
Average= 3.66
(KJ/cycle)

Cycle 47 : GMT 29/ 1/2026 15:34: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.00 31 15.11 478 224 0.22 / 172.01 2 3
2 7 2005.44 38 14.89 2780 1573 1.80 / 173.59 2 5
3 13 1339.68 18 14.95 2005 540 2.34 / 174.12 2 7
4 13 817.28 18 15.02 1376 372 2.71 / 174.50 2 8
5 13 209.20 18 15.17 600 164 2.87 / 174.66 2 10
6 13 20.84 18 15.20 339 93 2.97 / 174.75 2 8
7 8 -0.16 165 15.15 311 777 3.74 / 175.53 2 15
Average= 3.66
(KJ/cycle)

Cycle 46 : GMT 19/ 1/2026 20:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.16 31 15.11 467 219 0.22 / 168.39 3 3
2 7 2004.04 38 14.88 2771 1567 1.79 / 169.96 2 6
3 13 1335.44 18 14.95 2003 539 2.32 / 170.50 2 7
4 13 769.36 18 15.03 1319 357 2.68 / 170.85 2 8
5 13 188.28 18 15.18 577 158 2.84 / 171.01 2 9
6 8 0.24 165 15.16 311 778 3.62 / 171.79 2 14
Average= 3.66
(KJ/cycle)

Cycle 45 : GMT 10/ 1/2026 1:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.00 31 15.11 479 224 0.22 / 164.75 3 4
2 7 2006.28 38 14.90 2765 1566 1.79 / 166.31 2 6
3 13 1299.04 18 14.97 1956 527 2.32 / 166.84 2 7
4 13 814.80 18 15.03 1379 373 2.69 / 167.21 2 9
5 13 212.44 18 15.17 608 166 2.86 / 167.38 2 9
6 8 0.20 165 15.17 316 791 3.65 / 168.17 2 14
Average= 3.66
(KJ/cycle)

Cycle 44 : GMT 31/12/2025 6:26: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.32 31 15.12 478 224 0.22 / 161.10 3 4
2 7 2008.36 38 14.89 2788 1578 1.80 / 162.68 2 6
3 13 1302.72 18 14.95 1960 527 2.33 / 163.21 2 8
4 13 820.04 18 15.02 1383 374 2.70 / 163.58 2 9
5 13 169.08 18 15.18 548 150 2.85 / 163.73 2 9
6 8 -0.04 165 15.17 316 791 3.64 / 164.52 2 17
Average= 3.66
(KJ/cycle)

Cycle 43 : GMT 21/12/2025 11:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.12 31 15.13 484 227 0.23 / 157.41 2 4
2 7 2002.96 38 14.90 2785 1577 1.80 / 158.99 2 6
3 13 1381.80 18 14.94 2064 555 2.36 / 159.54 2 8
4 13 843.08 18 15.04 1411 382 2.74 / 159.93 2 9
5 13 195.60 18 15.19 588 161 2.90 / 160.09 2 9
6 8 0.04 165 15.18 317 794 3.70 / 160.88 2 13
Average= 3.66
(KJ/cycle)

Cycle 42 : GMT 11/12/2025 16:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.36 31 15.13 478 224 0.22 / 153.74 3 4
2 7 2011.72 39 14.90 2788 1620 1.84 / 155.36 2 5
3 13 1298.00 18 14.97 1960 528 2.37 / 155.89 2 8
4 13 741.24 18 15.06 1291 350 2.72 / 156.24 2 8
5 13 160.08 18 15.19 544 149 2.87 / 156.39 2 9
6 8 0.20 165 15.18 317 794 3.67 / 157.18 2 15
Average= 3.66
(KJ/cycle)

Cycle 41 : GMT 1/12/2025 21: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.88 31 15.14 478 224 0.22 / 150.06 2 3
2 7 2003.68 38 14.90 2787 1578 1.80 / 151.64 2 6
3 13 1371.84 18 14.96 2062 555 2.36 / 152.19 2 7
4 13 833.56 18 15.03 1402 379 2.74 / 152.57 2 8
5 13 174.72 18 15.20 563 154 2.89 / 152.73 2 9
6 8 0.12 165 15.19 316 792 3.68 / 153.52 2 14
Average= 3.66
(KJ/cycle)

Cycle 40 : GMT 22/11/2025 2: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.96 31 15.13 476 223 0.22 / 146.28 2 4
2 7 2002.96 38 14.90 2762 1564 1.79 / 147.84 2 5
3 13 1345.08 18 14.97 2006 541 2.33 / 148.39 2 7
4 13 807.56 18 15.05 1359 368 2.70 / 148.75 2 8
5 13 159.52 18 15.21 542 148 2.84 / 148.90 2 9
6 8 0.12 165 15.19 316 792 3.64 / 149.69 2 15
7 14 0.12 30 15.16 314 143 3.78 / 149.84 2 18
Average= 3.65
(KJ/cycle)

Cycle 39 : GMT 12/11/2025 7: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.08 31 15.13 484 227 0.23 / 142.63 2 4
2 7 2006.24 38 14.90 2783 1576 1.80 / 144.21 2 6
3 13 1341.24 18 14.97 2012 542 2.34 / 144.75 2 7
4 13 803.56 18 15.05 1361 369 2.71 / 145.12 2 8
5 13 163.16 18 15.19 546 149 2.86 / 145.27 2 9
6 8 0.04 165 15.19 316 792 3.65 / 146.06 2 12
Average= 3.65
(KJ/cycle)

Cycle 38 : GMT 2/11/2025 12: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.16 31 15.13 486 228 0.23 / 138.97 2 4
2 7 2002.04 38 14.91 2777 1573 1.80 / 140.54 2 4
3 13 1337.96 18 14.96 2017 543 2.34 / 141.08 2 7
4 13 856.12 18 15.03 1427 386 2.73 / 141.47 2 8
5 13 162.16 18 15.20 547 150 2.88 / 141.62 2 9
6 8 0.24 165 15.19 313 784 3.66 / 142.40 2 15
Average= 3.65
(KJ/cycle)

Cycle 37 : GMT 23/10/2025 17: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.36 31 15.14 477 224 0.22 / 135.29 2 5
2 7 2005.72 38 14.91 2788 1580 1.80 / 136.86 2 5
3 13 1376.68 18 14.96 2063 556 2.36 / 137.42 2 8
4 13 835.08 18 15.04 1402 380 2.74 / 137.80 2 9
5 13 140.12 18 15.20 517 141 2.88 / 137.94 2 9
6 8 0.12 165 15.19 318 797 3.68 / 138.74 2 15
Average= 3.65
(KJ/cycle)

Cycle 36 : GMT 13/10/2025 21:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.92 31 15.15 469 220 0.22 / 131.62 2 4
2 7 2002.44 38 14.91 2761 1564 1.78 / 133.18 2 7
3 13 1367.12 18 14.97 2045 551 2.34 / 133.73 2 7
4 13 830.56 18 15.04 1394 377 2.71 / 134.11 2 8
5 13 172.28 18 15.20 562 154 2.87 / 134.26 2 9
6 8 -0.04 165 15.19 318 797 3.66 / 135.06 2 17
Average= 3.65
(KJ/cycle)

Cycle 35 : GMT 4/10/2025 2:57: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.56 31 15.15 463 217 0.22 / 127.81 2 4
2 7 2004.72 38 14.91 2769 1569 1.79 / 129.38 2 7
3 13 1350.00 18 14.97 2025 546 2.33 / 129.92 2 7
4 13 894.16 18 15.03 1475 399 2.73 / 130.32 2 9
5 13 145.40 18 15.22 523 143 2.87 / 130.46 2 9
6 8 0.16 165 15.19 316 792 3.67 / 131.26 2 14
7 14 0.16 30 15.17 310 141 3.81 / 131.40 2 13
Average= 3.65
(KJ/cycle)

Cycle 34 : GMT 24/ 9/2025 7:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.60 31 15.14 483 227 0.23 / 124.16 2 4
2 7 2013.00 38 14.90 2796 1583 1.81 / 125.74 2 5
3 13 1311.24 18 14.96 1975 532 2.34 / 126.27 2 8
4 13 792.60 18 15.06 1354 367 2.71 / 126.64 2 9
5 13 180.04 18 15.19 562 154 2.86 / 126.80 2 10
6 8 0.20 165 15.19 317 795 3.66 / 127.59 2 16
Average= 3.65
(KJ/cycle)

Cycle 33 : GMT 14/ 9/2025 12:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.16 31 15.15 479 225 0.22 / 120.51 2 4
2 7 2005.24 38 14.91 2788 1580 1.80 / 122.09 2 5
3 13 1330.08 18 14.99 2011 543 2.35 / 122.63 2 8
4 13 763.56 18 15.07 1315 357 2.70 / 122.99 2 8
5 13 170.84 18 15.21 556 152 2.86 / 123.14 2 9
6 8 0.04 165 15.21 317 796 3.65 / 123.93 2 15
Average= 3.65
(KJ/cycle)

Cycle 32 : GMT 4/ 9/2025 17:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 31 15.17 463 218 0.22 / 116.69 2 4
2 7 2009.68 38 14.91 2781 1576 1.79 / 118.27 2 5
3 13 1383.00 18 14.97 2067 557 2.35 / 118.82 2 7
4 13 803.64 18 15.07 1361 369 2.72 / 119.19 2 9
5 13 197.64 18 15.21 591 162 2.88 / 119.35 2 9
6 8 0.08 165 15.20 314 788 3.67 / 120.14 2 17
7 14 0.08 30 15.18 309 141 3.81 / 120.28 2 15
Average= 3.64
(KJ/cycle)

Cycle 31 : GMT 25/ 8/2025 22:41: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.24 31 15.15 479 225 0.22 / 113.03 2 5
2 3 993.28 -1 15.50 0 0 0.00 / 113.03 2 5
3 3 1016.08 1 15.24 1663 25 0.25 / 113.06 2 4
4 7 2005.16 38 14.92 2786 1580 1.83 / 114.64 2 6
5 13 1343.04 18 14.99 2016 544 2.37 / 115.18 2 7
6 13 774.32 18 15.07 1326 360 2.73 / 115.54 2 9
7 13 141.56 18 15.23 516 141 2.87 / 115.68 2 9
8 8 0.04 165 15.21 315 791 3.67 / 116.47 2 14
Average= 3.64
(KJ/cycle)

Cycle 30 : GMT 16/ 8/2025 3:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.28 31 15.16 476 224 0.22 / 109.35 3 4
2 7 2003.44 38 14.93 2779 1577 1.80 / 110.93 2 5
3 13 1373.96 18 14.99 2057 555 2.36 / 111.49 2 9
4 13 833.72 18 15.07 1404 381 2.74 / 111.87 2 8
5 13 143.88 18 15.24 516 142 2.88 / 112.01 2 10
6 8 0.28 165 15.21 318 798 3.68 / 112.81 2 13
Average= 3.64
(KJ/cycle)

Cycle 29 : GMT 6/ 8/2025 8:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.32 31 15.17 477 224 0.22 / 105.73 2 4
2 7 2003.28 38 14.92 2770 1570 1.79 / 107.30 2 5
3 13 1294.52 18 14.99 1958 528 2.32 / 107.83 2 8
4 13 770.56 18 15.08 1320 358 2.68 / 108.19 2 8
5 13 170.56 18 15.22 550 151 2.83 / 108.34 2 9
6 8 0.28 165 15.21 316 793 3.63 / 109.13 2 15
Average= 3.64
(KJ/cycle)

Cycle 28 : GMT 27/ 7/2025 13:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.48 31 15.16 486 228 0.23 / 102.08 3 4
2 7 2003.84 38 14.92 2785 1579 1.81 / 103.66 2 6
3 13 1337.68 18 15.00 2020 545 2.35 / 104.20 2 7
4 13 801.12 18 15.08 1353 367 2.72 / 104.57 2 8
5 13 149.76 18 15.23 530 145 2.87 / 104.71 2 9
6 8 -0.04 165 15.22 315 791 3.66 / 105.51 2 12
Average= 3.64
(KJ/cycle)

Cycle 27 : GMT 17/ 7/2025 18:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.12 31 15.17 479 225 0.23 / 98.44 2 4
2 7 2007.20 38 14.93 2770 1572 1.80 / 100.01 2 6
3 13 1291.00 18 15.00 1950 526 2.32 / 100.54 2 7
4 13 810.96 18 15.08 1363 370 2.69 / 100.91 2 8
5 13 150.64 18 15.23 523 143 2.84 / 101.05 2 9
6 8 0.00 165 15.22 317 796 3.63 / 101.85 2 14
Average= 3.64
(KJ/cycle)

Cycle 26 : GMT 7/ 7/2025 23:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.76 31 15.17 480 226 0.23 / 94.61 2 4
2 7 2004.24 39 14.93 2782 1620 1.85 / 96.23 2 6
3 13 1293.12 18 15.00 1960 529 2.37 / 96.76 2 8
4 13 766.48 18 15.10 1331 362 2.74 / 97.12 2 9
5 13 163.96 18 15.23 548 150 2.89 / 97.27 2 9
6 8 0.20 165 15.22 320 804 3.69 / 98.07 2 19
7 14 0.20 30 15.20 315 144 3.83 / 98.22 2 17
Average= 3.64
(KJ/cycle)

Cycle 25 : GMT 28/ 6/2025 4: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.96 30 15.18 475 216 0.22 / 90.81 2 4
2 7 2007.28 38 14.93 2762 1567 1.78 / 92.38 2 5
3 13 1333.88 18 15.00 1994 538 2.32 / 92.92 2 8
4 13 839.60 18 15.07 1404 381 2.70 / 93.30 2 8
5 13 176.56 18 15.23 562 154 2.86 / 93.46 2 9
6 8 -0.04 165 15.22 313 786 3.64 / 94.24 2 16
7 14 -0.04 30 15.19 310 141 3.78 / 94.38 3 18
Average= 3.63
(KJ/cycle)

Cycle 24 : GMT 18/ 6/2025 9: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.28 30 15.18 485 221 0.22 / 87.15 2 4
2 7 2004.08 38 14.94 2777 1577 1.80 / 88.73 2 6
3 13 1384.72 18 15.00 2067 558 2.36 / 89.29 2 7
4 13 796.76 18 15.09 1349 366 2.72 / 89.65 2 9
5 13 160.52 18 15.23 540 148 2.87 / 89.80 2 9
6 8 0.32 165 15.23 317 797 3.67 / 90.60 2 15
Average= 3.62
(KJ/cycle)

Cycle 23 : GMT 8/ 6/2025 14: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.44 30 15.18 475 216 0.22 / 83.37 2 4
2 7 2004.88 38 14.94 2770 1573 1.79 / 84.94 2 6
3 13 1293.60 18 15.01 1958 529 2.32 / 85.47 2 7
4 13 772.72 18 15.09 1324 360 2.68 / 85.83 2 9
5 13 207.12 18 15.23 603 165 2.84 / 85.99 2 9
6 8 -0.12 165 15.24 316 795 3.64 / 86.79 2 15
7 14 -0.12 30 15.21 314 143 3.78 / 86.93 2 21
Average= 3.62
(KJ/cycle)

Cycle 22 : GMT 29/ 5/2025 18:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.12 30 15.19 462 211 0.21 / 79.75 2 4
2 7 2003.08 38 14.94 2782 1579 1.79 / 81.33 2 5
3 13 1298.88 18 15.02 1962 530 2.32 / 81.86 2 7
4 13 776.88 18 15.10 1328 361 2.68 / 82.22 2 8
5 13 135.60 18 15.26 503 138 2.82 / 82.36 2 8
6 8 0.16 165 15.23 314 789 3.61 / 83.15 2 15
Average= 3.62
(KJ/cycle)

Cycle 21 : GMT 19/ 5/2025 23:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.16 30 15.19 466 212 0.21 / 76.02 3 3
2 7 2003.96 38 14.94 2764 1569 1.78 / 77.59 2 6
3 13 1339.28 18 15.03 1987 538 2.32 / 78.12 2 9
4 13 787.24 18 15.12 1310 357 2.68 / 78.48 2 8
5 13 139.64 18 15.27 491 135 2.81 / 78.61 2 9
6 8 0.12 165 15.24 313 787 3.60 / 79.40 2 12
7 14 0.12 30 15.22 309 141 3.74 / 79.54 2 16
Average= 3.62
(KJ/cycle)

Cycle 20 : GMT 10/ 5/2025 4:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.72 30 15.18 467 213 0.21 / 72.38 3 4
2 7 2004.68 38 14.95 2779 1579 1.79 / 73.96 2 5
3 13 1333.12 18 15.02 2004 542 2.33 / 74.50 2 8
4 13 797.68 18 15.10 1354 368 2.70 / 74.87 2 8
5 13 168.04 18 15.25 549 151 2.85 / 75.02 2 9
6 8 0.24 165 15.24 312 785 3.64 / 75.80 2 15
Average= 3.61
(KJ/cycle)

Cycle 19 : GMT 30/ 4/2025 9:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.32 30 15.18 463 211 0.21 / 68.79 2 4
2 7 2005.00 38 14.94 2771 1573 1.78 / 70.36 2 6
3 13 1331.44 18 15.01 1998 540 2.32 / 70.90 2 7
4 13 728.64 18 15.12 1265 344 2.67 / 71.24 2 9
5 13 145.52 18 15.25 516 142 2.81 / 71.39 2 9
6 8 0.08 165 15.24 311 782 3.59 / 72.17 2 15
Average= 3.61
(KJ/cycle)

Cycle 18 : GMT 20/ 4/2025 14:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.56 30 15.18 476 217 0.22 / 65.10 3 4
2 7 2003.68 38 14.95 2770 1574 1.79 / 66.67 2 6
3 13 1253.48 18 15.04 1886 511 2.30 / 67.18 2 7
4 13 857.48 18 15.09 1424 387 2.69 / 67.57 2 9
5 13 121.16 18 15.26 480 132 2.82 / 67.70 2 9
6 13 37.28 18 15.26 362 99 2.92 / 67.80 2 8
7 8 0.08 165 15.23 309 777 3.70 / 68.58 2 16
Average= 3.61
(KJ/cycle)

Cycle 17 : GMT 10/ 4/2025 19:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.08 30 15.19 465 212 0.21 / 61.50 3 4
2 7 2004.04 38 14.95 2743 1558 1.77 / 63.06 2 6
3 13 1333.84 18 15.03 1982 536 2.31 / 63.60 2 8
4 13 752.88 18 15.11 1286 350 2.66 / 63.95 2 9
5 13 192.60 18 15.25 574 158 2.81 / 64.10 2 9
6 8 0.16 165 15.24 309 777 3.59 / 64.88 2 14
Average= 3.60
(KJ/cycle)

Cycle 16 : GMT 1/ 4/2025 0:17: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.56 30 15.20 475 217 0.22 / 57.90 2 4
2 7 2007.00 38 14.95 2771 1574 1.79 / 59.48 2 6
3 13 1286.12 18 15.03 1942 525 2.32 / 60.00 2 8
4 13 838.64 18 15.09 1387 377 2.69 / 60.38 2 8
5 13 135.12 18 15.26 498 137 2.83 / 60.52 2 9
6 8 0.08 165 15.24 307 772 3.60 / 61.29 2 14
Average= 3.61
(KJ/cycle)

Cycle 15 : GMT 22/ 3/2025 5:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.20 30 15.21 472 215 0.22 / 54.24 2 4
2 7 2003.84 38 14.96 2775 1578 1.79 / 55.82 2 6
3 13 1383.20 18 15.03 2066 559 2.35 / 56.38 2 7
4 13 804.52 18 15.11 1360 370 2.72 / 56.75 2 7
5 13 211.72 18 15.25 607 167 2.89 / 56.92 2 9
6 8 0.08 165 15.25 306 770 3.66 / 57.69 2 13
Average= 3.61
(KJ/cycle)

Cycle 14 : GMT 12/ 3/2025 10:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.28 30 15.21 462 211 0.21 / 50.60 3 3
2 7 2007.44 38 14.98 2782 1584 1.79 / 52.18 2 5
3 13 1394.88 18 15.05 2070 561 2.36 / 52.74 2 6
4 13 808.52 18 15.13 1352 368 2.72 / 53.11 2 8
5 13 164.84 18 15.27 544 150 2.87 / 53.26 2 9
6 8 0.20 165 15.26 306 770 3.64 / 54.03 2 14
Average= 3.60
(KJ/cycle)

Cycle 13 : GMT 2/ 3/2025 15:12:22

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.76 30 15.22 470 215 0.21 / 46.99 3 3
2 7 2007.04 38 14.97 2768 1575 1.79 / 48.56 2 5
3 13 1333.84 18 15.05 2002 542 2.33 / 49.10 2 7
4 13 796.40 18 15.14 1347 367 2.70 / 49.47 2 8
5 13 142.84 18 15.28 511 141 2.84 / 49.61 2 9
6 8 0.08 165 15.26 308 776 3.61 / 50.39 2 13
Average= 3.60
(KJ/cycle)

Cycle 12 : GMT 20/ 2/2025 20:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.92 30 15.22 467 213 0.21 / 43.36 2 4
2 7 2003.96 38 14.97 2765 1573 1.79 / 44.93 2 5
3 13 1331.88 18 15.06 1990 539 2.33 / 45.47 2 6
4 13 831.64 18 15.13 1390 379 2.70 / 45.85 2 8
5 13 169.92 18 15.28 548 151 2.85 / 46.00 2 9
6 8 0.00 165 15.27 306 771 3.63 / 46.77 2 14
Average= 3.60
(KJ/cycle)

Cycle 11 : GMT 11/ 2/2025 1:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.44 30 15.23 471 215 0.22 / 39.76 2 4
2 7 2003.60 39 14.98 2752 1608 1.82 / 41.36 2 6
3 13 1327.04 18 15.07 1968 534 2.36 / 41.90 2 7
4 13 747.32 18 15.15 1280 349 2.71 / 42.25 2 8
5 13 144.36 18 15.29 502 138 2.84 / 42.38 2 8
6 8 0.04 165 15.27 302 761 3.60 / 43.15 2 22
Average= 3.60
(KJ/cycle)

Cycle 10 : GMT 1/ 2/2025 6: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.36 30 15.23 462 211 0.21 / 35.36 3 3
2 7 2004.12 74 14.87 2770 3048 3.26 / 38.41 2 6
3 13 466.12 18 15.23 925 254 3.51 / 38.67 2 9
4 13 53.52 18 15.33 382 105 3.62 / 38.77 2 9
5 8 -0.08 165 15.29 305 769 4.39 / 39.54 2 16
Average= 3.59
(KJ/cycle)

Cycle 9 : GMT 22/ 1/2025 8:57: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.28 28 15.24 462 197 0.20 / 30.66 2 3
2 10 1007.16 2 15.27 1644 50 0.25 / 30.71 2 4
3 7 2006.80 74 14.86 2753 3027 3.27 / 33.74 2 9
4 13 441.40 18 15.23 874 240 3.51 / 33.98 2 9
5 13 21.96 18 15.33 305 84 3.60 / 34.06 2 8
6 8 0.04 165 15.29 297 749 4.35 / 34.81 2 16
7 14 0.04 75 15.24 297 339 4.69 / 35.15 2 15
Average= 3.52
(KJ/cycle)

Cycle 8 : GMT 12/ 1/2025 11:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.48 31 15.23 460 217 0.22 / 26.31 2 4
2 3 955.20 -1 15.63 0 0 0.00 / 26.31 2 4
3 3 972.48 -1 15.65 0 0 0.00 / 26.31 2 4
4 7 2002.36 74 14.87 2761 3038 3.26 / 29.35 2 9
5 13 506.72 18 15.22 973 267 3.52 / 29.62 2 9
6 13 22.60 18 15.33 333 92 3.61 / 29.71 2 9
7 8 0.12 165 15.28 300 756 4.37 / 30.47 2 14
Average= 3.39
(KJ/cycle)

Cycle 7 : GMT 2/ 1/2025 14:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.72 29 15.25 457 202 0.20 / 22.36 2 3
2 7 1805.64 74 14.92 2537 2801 3.00 / 25.16 2 6
3 13 249.08 18 15.28 644 177 3.18 / 25.34 2 9
4 8 0.20 165 15.29 300 757 3.94 / 26.10 2 16
Average= 3.26
(KJ/cycle)

Cycle 6 : GMT 1/ 1/2025 13:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.96 29 15.23 451 199 0.20 / 18.79 2 3
2 7 1509.00 74 15.04 2191 2438 2.64 / 21.23 2 6
3 13 244.80 18 15.30 635 175 2.81 / 21.41 2 8
4 8 0.24 165 15.31 298 753 3.57 / 22.16 2 14
Average= 3.17
(KJ/cycle)

Cycle 5 : GMT 31/12/2024 14:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.68 29 15.25 459 203 0.20 / 14.88 2 4
2 7 1522.08 74 15.03 2200 2447 2.65 / 17.33 2 7
3 13 243.68 18 15.30 635 175 2.82 / 17.50 2 9
4 8 0.28 165 15.30 298 752 3.58 / 18.25 2 15
5 14 0.28 75 15.27 297 340 3.92 / 18.59 3 17
Average= 3.10
(KJ/cycle)

Cycle 4 : GMT 30/12/2024 14:42: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.24 28 15.24 450 192 0.19 / 11.28 2 4
2 3 1021.68 1 15.32 1671 26 0.22 / 11.31 2 5
3 7 1526.96 74 15.03 2204 2451 2.67 / 13.76 2 6
4 13 244.80 18 15.30 622 171 2.84 / 13.93 2 9
5 8 -0.08 165 15.31 295 745 3.59 / 14.68 2 16
Average= 2.94
(KJ/cycle)

Cycle 3 : GMT 29/12/2024 15:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.56 24 15.27 434 159 0.16 / 7.63 3 4
2 10 1042.96 3 15.24 1686 77 0.24 / 7.71 2 4
3 3 1050.40 1 15.31 1686 26 0.26 / 7.73 2 6
4 7 1525.44 74 15.03 2196 2442 2.70 / 10.17 2 8
5 13 240.40 18 15.29 625 172 2.88 / 10.35 2 9
6 8 0.04 165 15.30 295 745 3.62 / 11.09 2 13
Average= 2.77
(KJ/cycle)

Cycle 2 : GMT 28/12/2024 15:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.00 33 15.32 429 217 0.22 / 4.26 2 4
2 3 806.64 -4 15.65 0 0 0.00 / 4.26 2 4
3 3 886.16 -2 15.67 0 0 0.00 / 4.26 2 4
4 7 1507.72 74 15.04 2153 2396 2.61 / 6.66 2 6
5 13 141.88 18 15.32 471 130 2.74 / 6.79 2 9
6 8 0.04 165 15.31 269 680 3.42 / 7.47 2 14
Average= 2.49
(KJ/cycle)

Cycle 1 : GMT 27/12/2024 16: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.92 28 15.46 381 165 0.16 / 1.63 3 3
2 3 970.36 -1 15.66 0 0 0.00 / 1.63 3 3
3 7 996.76 74 15.21 1537 1730 1.89 / 3.36 2 9
4 8 -0.12 165 15.37 269 682 2.58 / 4.05 2 17
Average= 2.02
(KJ/cycle)

Cycle 0 : GMT 27/12/2024 5:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.28 28 15.62 387 169 0.17 / 0.17 3 3
2 7 127.48 74 15.57 403 464 0.63 / 0.63 3 4
3 8 0.44 240 15.55 224 836 1.47 / 1.47 3 15
Average= 1.47
(KJ/cycle)