SIO Argo Site:
|
|
|
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 107.40 | 28 | 15.13 | 444 | 188 | 0.19 / 185.31 | 2 | 2 |
| 2 | 10 | 1006.76 | 2 | 15.17 | 1484 | 45 | 0.23 / 185.35 | 2 | 3 |
| 3 | 3 | 976.44 | -1 | 15.49 | 1 | 0 | 0.05 / 185.35 | 2 | 3 |
| 4 | 7 | 2003.52 | 38 | 14.92 | 2686 | 1523 | 1.76 / 186.87 | 2 | 4 |
| 5 | 13 | 1365.76 | 18 | 14.98 | 1947 | 525 | 2.28 / 187.40 | 2 | 3 |
| 6 | 13 | 843.36 | 18 | 15.06 | 1286 | 349 | 2.63 / 187.75 | 2 | 3 |
| 7 | 13 | 287.64 | 18 | 15.17 | 663 | 181 | 2.81 / 187.93 | 2 | 4 |
| 8 | 8 | 0.08 | 165 | 15.20 | 285 | 715 | 3.53 / 188.64 | 2 | 15 |
| Average= | 3.49 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 107.00 | 28 | 15.15 | 432 | 183 | 0.18 / 181.80 | 2 | 2 |
| 2 | 7 | 2003.08 | 38 | 14.91 | 2683 | 1520 | 1.70 / 183.32 | 2 | 3 |
| 3 | 13 | 1395.04 | 18 | 14.97 | 1958 | 528 | 2.23 / 183.85 | 2 | 3 |
| 4 | 13 | 868.00 | 18 | 15.05 | 1276 | 346 | 2.58 / 184.20 | 2 | 3 |
| 5 | 13 | 346.56 | 18 | 15.15 | 734 | 200 | 2.78 / 184.40 | 2 | 4 |
| 6 | 8 | 0.00 | 165 | 15.19 | 288 | 722 | 3.50 / 185.12 | 2 | 14 |
| Average= | 3.49 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 105.56 | 28 | 15.13 | 432 | 183 | 0.18 / 178.27 | 2 | 2 |
| 2 | 7 | 2008.56 | 39 | 14.92 | 2693 | 1567 | 1.75 / 179.84 | 2 | 3 |
| 3 | 13 | 1361.32 | 18 | 14.97 | 1933 | 521 | 2.27 / 180.36 | 2 | 3 |
| 4 | 13 | 883.56 | 18 | 15.06 | 1309 | 355 | 2.63 / 180.71 | 2 | 3 |
| 5 | 13 | 305.00 | 18 | 15.17 | 677 | 185 | 2.81 / 180.90 | 2 | 3 |
| 6 | 8 | 0.24 | 165 | 15.20 | 287 | 720 | 3.53 / 181.62 | 2 | 13 |
| Average= | 3.49 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 105.72 | 28 | 15.15 | 433 | 184 | 0.18 / 174.63 | 2 | 2 |
| 2 | 7 | 2011.76 | 38 | 14.91 | 2714 | 1538 | 1.72 / 176.17 | 2 | 3 |
| 3 | 13 | 1419.76 | 18 | 14.95 | 1996 | 537 | 2.26 / 176.71 | 2 | 3 |
| 4 | 13 | 894.16 | 18 | 15.04 | 1335 | 361 | 2.62 / 177.07 | 2 | 4 |
| 5 | 13 | 359.76 | 18 | 15.15 | 756 | 206 | 2.83 / 177.28 | 2 | 4 |
| 6 | 13 | 19.00 | 18 | 15.23 | 320 | 88 | 2.91 / 177.36 | 2 | 4 |
| 7 | 8 | -0.12 | 165 | 15.19 | 289 | 724 | 3.64 / 178.09 | 2 | 13 |
| Average= | 3.49 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 108.08 | 27 | 15.15 | 445 | 182 | 0.18 / 171.12 | 2 | 2 |
| 2 | 7 | 2008.40 | 38 | 14.91 | 2697 | 1528 | 1.71 / 172.65 | 2 | 3 |
| 3 | 13 | 1407.24 | 18 | 14.96 | 2003 | 539 | 2.25 / 173.19 | 2 | 4 |
| 4 | 13 | 910.64 | 18 | 15.05 | 1372 | 372 | 2.62 / 173.56 | 2 | 3 |
| 5 | 13 | 249.08 | 18 | 15.19 | 619 | 169 | 2.79 / 173.73 | 2 | 4 |
| 6 | 8 | 0.24 | 165 | 15.20 | 287 | 720 | 3.51 / 174.45 | 2 | 13 |
| Average= | 3.49 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 105.60 | 28 | 15.15 | 434 | 184 | 0.18 / 167.59 | 2 | 3 |
| 2 | 7 | 2003.36 | 38 | 14.91 | 2696 | 1527 | 1.71 / 169.12 | 2 | 3 |
| 3 | 13 | 1392.76 | 18 | 14.97 | 1971 | 531 | 2.24 / 169.65 | 2 | 4 |
| 4 | 13 | 906.52 | 18 | 15.05 | 1350 | 366 | 2.61 / 170.02 | 2 | 4 |
| 5 | 13 | 365.36 | 18 | 15.16 | 744 | 203 | 2.81 / 170.22 | 2 | 4 |
| 6 | 8 | -0.24 | 165 | 15.21 | 287 | 720 | 3.53 / 170.94 | 2 | 10 |
| Average= | 3.49 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 108.48 | 27 | 15.15 | 441 | 180 | 0.18 / 164.07 | 2 | 2 |
| 2 | 7 | 2003.36 | 38 | 14.91 | 2697 | 1528 | 1.71 / 165.60 | 2 | 3 |
| 3 | 13 | 1354.60 | 18 | 14.98 | 1900 | 512 | 2.22 / 166.11 | 2 | 4 |
| 4 | 13 | 918.80 | 18 | 15.04 | 1407 | 381 | 2.60 / 166.49 | 2 | 4 |
| 5 | 13 | 325.72 | 18 | 15.17 | 709 | 194 | 2.80 / 166.69 | 2 | 3 |
| 6 | 8 | 0.20 | 165 | 15.21 | 288 | 723 | 3.52 / 167.41 | 2 | 10 |
| Average= | 3.49 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 105.72 | 27 | 15.15 | 438 | 179 | 0.18 / 160.53 | 2 | 2 |
| 2 | 7 | 2003.68 | 38 | 14.91 | 2684 | 1521 | 1.70 / 162.05 | 2 | 3 |
| 3 | 13 | 1450.00 | 18 | 14.95 | 2055 | 553 | 2.25 / 162.61 | 2 | 3 |
| 4 | 13 | 872.36 | 18 | 15.06 | 1314 | 356 | 2.61 / 162.96 | 2 | 4 |
| 5 | 13 | 349.00 | 18 | 15.16 | 732 | 200 | 2.81 / 163.16 | 2 | 4 |
| 6 | 8 | 0.08 | 165 | 15.21 | 290 | 728 | 3.54 / 163.89 | 2 | 14 |
| Average= | 3.49 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 106.84 | 27 | 15.15 | 445 | 182 | 0.18 / 157.06 | 2 | 2 |
| 2 | 7 | 2005.36 | 38 | 14.92 | 2700 | 1531 | 1.71 / 158.59 | 2 | 3 |
| 3 | 13 | 1322.76 | 18 | 14.98 | 1912 | 516 | 2.23 / 159.10 | 2 | 3 |
| 4 | 13 | 858.68 | 18 | 15.07 | 1278 | 347 | 2.58 / 159.45 | 2 | 3 |
| 5 | 13 | 301.76 | 18 | 15.17 | 680 | 186 | 2.76 / 159.63 | 2 | 4 |
| 6 | 8 | 0.20 | 165 | 15.21 | 287 | 720 | 3.48 / 160.35 | 2 | 11 |
| Average= | 3.49 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 106.12 | 27 | 15.16 | 442 | 181 | 0.18 / 153.39 | 2 | 2 |
| 2 | 7 | 2006.40 | 38 | 14.93 | 2693 | 1528 | 1.71 / 154.92 | 2 | 3 |
| 3 | 13 | 1403.44 | 18 | 14.98 | 1995 | 538 | 2.25 / 155.46 | 2 | 3 |
| 4 | 13 | 962.32 | 18 | 15.04 | 1411 | 382 | 2.63 / 155.84 | 2 | 4 |
| 5 | 13 | 411.68 | 18 | 15.15 | 812 | 221 | 2.85 / 156.06 | 2 | 4 |
| 6 | 13 | 23.08 | 18 | 15.25 | 329 | 90 | 2.94 / 156.15 | 2 | 5 |
| 7 | 8 | 0.04 | 165 | 15.21 | 288 | 723 | 3.66 / 156.87 | 2 | 11 |
| Average= | 3.49 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 109.60 | 27 | 15.16 | 448 | 183 | 0.18 / 149.89 | 2 | 2 |
| 2 | 7 | 2009.04 | 38 | 14.93 | 2706 | 1535 | 1.72 / 151.42 | 2 | 3 |
| 3 | 13 | 1405.12 | 18 | 14.98 | 1990 | 537 | 2.26 / 151.96 | 2 | 4 |
| 4 | 13 | 881.00 | 18 | 15.08 | 1284 | 349 | 2.60 / 152.31 | 2 | 4 |
| 5 | 13 | 274.44 | 18 | 15.20 | 645 | 176 | 2.78 / 152.48 | 2 | 5 |
| 6 | 8 | 0.28 | 165 | 15.22 | 290 | 728 | 3.51 / 153.21 | 2 | 12 |
| Average= | 3.48 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 107.04 | 27 | 15.17 | 444 | 182 | 0.18 / 146.38 | 2 | 2 |
| 2 | 7 | 2010.20 | 38 | 14.93 | 2696 | 1530 | 1.71 / 147.91 | 2 | 3 |
| 3 | 13 | 1358.32 | 18 | 15.00 | 1928 | 521 | 2.23 / 148.43 | 2 | 3 |
| 4 | 13 | 878.48 | 18 | 15.08 | 1313 | 356 | 2.59 / 148.79 | 2 | 3 |
| 5 | 13 | 306.36 | 18 | 15.19 | 677 | 185 | 2.77 / 148.97 | 2 | 3 |
| 6 | 8 | 0.08 | 165 | 15.23 | 291 | 731 | 3.50 / 149.70 | 2 | 12 |
| Average= | 3.48 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 105.04 | 27 | 15.17 | 430 | 176 | 0.18 / 142.86 | 2 | 2 |
| 2 | 7 | 2003.00 | 38 | 14.93 | 2695 | 1529 | 1.71 / 144.39 | 2 | 3 |
| 3 | 13 | 1358.08 | 18 | 14.98 | 1961 | 529 | 2.23 / 144.92 | 2 | 4 |
| 4 | 13 | 879.88 | 18 | 15.09 | 1301 | 353 | 2.59 / 145.27 | 2 | 3 |
| 5 | 13 | 309.96 | 18 | 15.19 | 692 | 189 | 2.78 / 145.46 | 2 | 4 |
| 6 | 8 | 0.24 | 165 | 15.23 | 293 | 736 | 3.51 / 146.20 | 2 | 11 |
| Average= | 3.48 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 107.00 | 27 | 15.17 | 447 | 183 | 0.18 / 139.36 | 2 | 2 |
| 2 | 7 | 2003.88 | 38 | 14.93 | 2696 | 1530 | 1.71 / 140.89 | 2 | 3 |
| 3 | 13 | 1359.76 | 18 | 14.99 | 1924 | 519 | 2.23 / 141.41 | 2 | 6 |
| 4 | 13 | 878.60 | 18 | 15.09 | 1286 | 349 | 2.58 / 141.76 | 2 | 3 |
| 5 | 13 | 346.64 | 18 | 15.18 | 734 | 201 | 2.78 / 141.96 | 2 | 4 |
| 6 | 8 | 0.12 | 165 | 15.22 | 289 | 726 | 3.51 / 142.68 | 2 | 12 |
| Average= | 3.48 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 105.84 | 27 | 15.18 | 444 | 182 | 0.18 / 135.79 | 2 | 2 |
| 2 | 7 | 2006.20 | 38 | 14.94 | 2704 | 1535 | 1.72 / 137.33 | 2 | 3 |
| 3 | 13 | 1409.16 | 18 | 14.98 | 1994 | 538 | 2.25 / 137.87 | 2 | 4 |
| 4 | 13 | 923.40 | 18 | 15.07 | 1361 | 369 | 2.62 / 138.23 | 2 | 3 |
| 5 | 13 | 388.84 | 18 | 15.17 | 773 | 211 | 2.84 / 138.45 | 2 | 4 |
| 6 | 8 | 0.12 | 165 | 15.23 | 291 | 731 | 3.57 / 139.18 | 2 | 13 |
| Average= | 3.48 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 109.84 | 27 | 15.19 | 452 | 185 | 0.19 / 132.28 | 2 | 2 |
| 2 | 7 | 2004.08 | 38 | 14.93 | 2713 | 1539 | 1.72 / 133.82 | 2 | 3 |
| 3 | 13 | 1366.24 | 18 | 14.99 | 1930 | 521 | 2.25 / 134.34 | 2 | 3 |
| 4 | 13 | 877.88 | 18 | 15.08 | 1298 | 352 | 2.60 / 134.69 | 2 | 3 |
| 5 | 13 | 301.08 | 18 | 15.20 | 673 | 184 | 2.78 / 134.87 | 2 | 4 |
| 6 | 8 | 0.24 | 165 | 15.23 | 293 | 736 | 3.52 / 135.61 | 2 | 13 |
| Average= | 3.48 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 114.64 | 27 | 15.20 | 450 | 185 | 0.18 / 128.75 | 2 | 2 |
| 2 | 7 | 2012.68 | 38 | 14.93 | 2709 | 1537 | 1.72 / 130.29 | 2 | 3 |
| 3 | 13 | 1363.60 | 18 | 15.01 | 1931 | 522 | 2.24 / 130.81 | 2 | 4 |
| 4 | 13 | 921.20 | 18 | 15.09 | 1382 | 375 | 2.62 / 131.19 | 2 | 4 |
| 5 | 13 | 245.52 | 18 | 15.22 | 617 | 169 | 2.79 / 131.36 | 2 | 4 |
| 6 | 8 | -0.32 | 165 | 15.25 | 293 | 737 | 3.52 / 132.09 | 2 | 11 |
| Average= | 3.48 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 109.56 | 27 | 15.17 | 442 | 181 | 0.18 / 125.21 | 2 | 3 |
| 2 | 7 | 2004.68 | 38 | 14.95 | 2705 | 1537 | 1.72 / 126.75 | 2 | 3 |
| 3 | 13 | 1412.16 | 18 | 15.00 | 2014 | 544 | 2.26 / 127.29 | 2 | 3 |
| 4 | 13 | 841.52 | 18 | 15.11 | 1256 | 342 | 2.60 / 127.64 | 2 | 4 |
| 5 | 13 | 373.48 | 18 | 15.20 | 748 | 205 | 2.81 / 127.84 | 2 | 4 |
| 6 | 8 | 0.40 | 165 | 15.24 | 289 | 727 | 3.53 / 128.57 | 2 | 10 |
| Average= | 3.47 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 106.16 | 27 | 15.18 | 436 | 179 | 0.18 / 121.72 | 2 | 2 |
| 2 | 7 | 2003.36 | 38 | 14.93 | 2700 | 1532 | 1.71 / 123.25 | 2 | 3 |
| 3 | 13 | 1310.36 | 18 | 15.01 | 1888 | 510 | 2.22 / 123.76 | 2 | 4 |
| 4 | 13 | 848.28 | 18 | 15.08 | 1316 | 357 | 2.58 / 124.12 | 2 | 3 |
| 5 | 13 | 278.20 | 18 | 15.20 | 652 | 178 | 2.76 / 124.30 | 2 | 4 |
| 6 | 8 | -0.16 | 165 | 15.24 | 292 | 734 | 3.49 / 125.03 | 2 | 12 |
| Average= | 3.47 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 118.20 | 27 | 15.18 | 449 | 184 | 0.18 / 118.18 | 2 | 2 |
| 2 | 7 | 2010.88 | 38 | 14.94 | 2706 | 1536 | 1.72 / 119.72 | 2 | 3 |
| 3 | 13 | 1418.64 | 18 | 14.99 | 1997 | 539 | 2.26 / 120.26 | 2 | 4 |
| 4 | 13 | 892.12 | 18 | 15.09 | 1304 | 354 | 2.61 / 120.61 | 2 | 4 |
| 5 | 13 | 363.92 | 18 | 15.19 | 745 | 204 | 2.82 / 120.81 | 2 | 4 |
| 6 | 8 | 0.36 | 165 | 15.24 | 290 | 729 | 3.55 / 121.54 | 2 | 15 |
| Average= | 3.47 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 106.84 | 27 | 15.20 | 442 | 181 | 0.18 / 114.67 | 2 | 2 |
| 2 | 7 | 2003.72 | 38 | 14.94 | 2699 | 1532 | 1.71 / 116.21 | 2 | 3 |
| 3 | 13 | 1365.16 | 18 | 15.02 | 1926 | 521 | 2.23 / 116.73 | 2 | 3 |
| 4 | 13 | 880.96 | 18 | 15.09 | 1349 | 366 | 2.60 / 117.09 | 2 | 3 |
| 5 | 13 | 272.48 | 18 | 15.21 | 643 | 176 | 2.78 / 117.27 | 2 | 4 |
| 6 | 8 | 0.24 | 165 | 15.24 | 289 | 727 | 3.50 / 118.00 | 2 | 13 |
| Average= | 3.47 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 111.00 | 27 | 15.18 | 447 | 183 | 0.18 / 111.17 | 2 | 2 |
| 2 | 7 | 2006.16 | 38 | 14.94 | 2693 | 1529 | 1.71 / 112.69 | 2 | 3 |
| 3 | 13 | 1398.40 | 18 | 14.99 | 1990 | 537 | 2.25 / 113.23 | 2 | 3 |
| 4 | 13 | 861.52 | 18 | 15.11 | 1264 | 344 | 2.59 / 113.58 | 2 | 4 |
| 5 | 13 | 333.12 | 18 | 15.20 | 716 | 196 | 2.79 / 113.77 | 2 | 5 |
| 6 | 8 | 0.16 | 165 | 15.24 | 287 | 722 | 3.51 / 114.49 | 2 | 13 |
| Average= | 3.47 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 104.16 | 28 | 15.20 | 441 | 188 | 0.19 / 107.68 | 2 | 3 |
| 2 | 7 | 2003.48 | 38 | 14.94 | 2690 | 1527 | 1.71 / 109.21 | 2 | 3 |
| 3 | 13 | 1400.24 | 18 | 15.01 | 1979 | 535 | 2.25 / 109.74 | 2 | 5 |
| 4 | 13 | 831.96 | 18 | 15.11 | 1241 | 338 | 2.59 / 110.08 | 2 | 4 |
| 5 | 13 | 273.20 | 18 | 15.23 | 646 | 177 | 2.76 / 110.26 | 2 | 4 |
| 6 | 8 | 0.12 | 165 | 15.25 | 288 | 725 | 3.49 / 110.98 | 2 | 6 |
| Average= | 3.47 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 100.64 | 28 | 15.21 | 428 | 182 | 0.18 / 104.18 | 2 | 2 |
| 2 | 7 | 2003.84 | 38 | 14.95 | 2698 | 1533 | 1.72 / 105.71 | 2 | 3 |
| 3 | 13 | 1346.64 | 18 | 15.03 | 1932 | 523 | 2.24 / 106.23 | 2 | 3 |
| 4 | 13 | 874.56 | 18 | 15.12 | 1288 | 351 | 2.59 / 106.58 | 2 | 3 |
| 5 | 13 | 260.92 | 18 | 15.24 | 637 | 175 | 2.76 / 106.76 | 2 | 4 |
| 6 | 8 | 0.28 | 165 | 15.26 | 292 | 735 | 3.50 / 107.49 | 2 | 13 |
| Average= | 3.47 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 106.24 | 28 | 15.20 | 426 | 181 | 0.18 / 100.69 | 2 | 2 |
| 2 | 7 | 2003.56 | 38 | 14.95 | 2685 | 1525 | 1.71 / 102.21 | 2 | 3 |
| 3 | 13 | 1393.84 | 18 | 15.01 | 1990 | 538 | 2.24 / 102.75 | 2 | 5 |
| 4 | 13 | 869.12 | 18 | 15.12 | 1268 | 345 | 2.59 / 103.10 | 2 | 4 |
| 5 | 13 | 293.04 | 18 | 15.23 | 656 | 180 | 2.77 / 103.28 | 2 | 3 |
| 6 | 8 | 0.04 | 165 | 15.25 | 286 | 720 | 3.49 / 104.00 | 2 | 10 |
| Average= | 3.47 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 110.04 | 27 | 15.20 | 448 | 184 | 0.18 / 97.19 | 2 | 2 |
| 2 | 7 | 2004.68 | 38 | 14.96 | 2693 | 1531 | 1.71 / 98.72 | 2 | 3 |
| 3 | 13 | 1357.76 | 18 | 15.03 | 1928 | 522 | 2.24 / 99.24 | 2 | 3 |
| 4 | 13 | 869.72 | 18 | 15.11 | 1294 | 352 | 2.59 / 99.60 | 2 | 3 |
| 5 | 13 | 299.04 | 18 | 15.22 | 671 | 184 | 2.77 / 99.78 | 2 | 4 |
| 6 | 8 | 0.00 | 165 | 15.25 | 289 | 727 | 3.50 / 100.51 | 2 | 13 |
| Average= | 3.47 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 115.72 | 27 | 15.18 | 443 | 182 | 0.18 / 93.66 | 2 | 3 |
| 2 | 7 | 2009.56 | 38 | 14.95 | 2702 | 1535 | 1.72 / 95.19 | 2 | 4 |
| 3 | 13 | 1395.96 | 18 | 15.01 | 1972 | 533 | 2.25 / 95.73 | 2 | 5 |
| 4 | 13 | 872.88 | 18 | 15.11 | 1315 | 358 | 2.61 / 96.08 | 2 | 4 |
| 5 | 13 | 331.44 | 18 | 15.22 | 714 | 196 | 2.80 / 96.28 | 2 | 4 |
| 6 | 8 | 0.28 | 165 | 15.25 | 289 | 727 | 3.53 / 97.01 | 2 | 13 |
| Average= | 3.46 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 112.88 | 28 | 15.21 | 433 | 184 | 0.18 / 90.13 | 2 | 2 |
| 2 | 7 | 2003.08 | 39 | 14.96 | 2699 | 1575 | 1.76 / 91.71 | 2 | 3 |
| 3 | 13 | 1392.92 | 18 | 15.03 | 1966 | 532 | 2.29 / 92.24 | 2 | 4 |
| 4 | 13 | 855.88 | 18 | 15.12 | 1255 | 342 | 2.63 / 92.58 | 2 | 3 |
| 5 | 13 | 245.08 | 18 | 15.22 | 612 | 168 | 2.80 / 92.75 | 2 | 4 |
| 6 | 8 | 0.04 | 165 | 15.24 | 290 | 729 | 3.53 / 93.48 | 2 | 12 |
| Average= | 3.46 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 113.88 | 28 | 15.19 | 446 | 190 | 0.19 / 86.64 | 2 | 2 |
| 2 | 7 | 2006.24 | 38 | 14.96 | 2703 | 1537 | 1.73 / 88.18 | 2 | 3 |
| 3 | 13 | 1350.80 | 18 | 15.04 | 1902 | 515 | 2.24 / 88.70 | 2 | 5 |
| 4 | 13 | 868.72 | 18 | 15.12 | 1290 | 351 | 2.59 / 89.05 | 2 | 3 |
| 5 | 13 | 289.76 | 18 | 15.24 | 660 | 181 | 2.77 / 89.23 | 2 | 4 |
| 6 | 8 | 0.20 | 165 | 15.26 | 286 | 720 | 3.49 / 89.95 | 2 | 12 |
| Average= | 3.46 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 107.28 | 28 | 15.21 | 431 | 184 | 0.18 / 83.14 | 2 | 2 |
| 2 | 7 | 2010.16 | 38 | 14.95 | 2712 | 1541 | 1.72 / 84.68 | 2 | 3 |
| 3 | 13 | 1351.00 | 18 | 15.03 | 1900 | 514 | 2.24 / 85.20 | 2 | 4 |
| 4 | 13 | 827.40 | 18 | 15.12 | 1290 | 351 | 2.59 / 85.55 | 2 | 3 |
| 5 | 13 | 298.04 | 18 | 15.23 | 672 | 184 | 2.77 / 85.73 | 2 | 4 |
| 6 | 8 | 0.12 | 165 | 15.26 | 287 | 723 | 3.50 / 86.45 | 2 | 13 |
| Average= | 3.46 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 108.56 | 28 | 15.21 | 438 | 187 | 0.19 / 79.62 | 2 | 2 |
| 2 | 7 | 2010.16 | 38 | 14.97 | 2709 | 1541 | 1.73 / 81.16 | 2 | 3 |
| 3 | 13 | 1408.92 | 18 | 15.02 | 2017 | 545 | 2.27 / 81.70 | 2 | 3 |
| 4 | 13 | 917.80 | 18 | 15.10 | 1368 | 372 | 2.64 / 82.08 | 2 | 4 |
| 5 | 13 | 218.00 | 18 | 15.25 | 577 | 158 | 2.80 / 82.23 | 2 | 4 |
| 6 | 8 | 0.00 | 165 | 15.27 | 287 | 723 | 3.53 / 82.96 | 2 | 13 |
| Average= | 3.46 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 103.56 | 28 | 15.21 | 427 | 182 | 0.18 / 76.11 | 2 | 2 |
| 2 | 7 | 2005.16 | 38 | 14.96 | 2703 | 1537 | 1.72 / 77.65 | 2 | 4 |
| 3 | 13 | 1344.92 | 18 | 15.03 | 1938 | 524 | 2.24 / 78.18 | 2 | 6 |
| 4 | 13 | 860.32 | 18 | 15.13 | 1297 | 353 | 2.60 / 78.53 | 2 | 3 |
| 5 | 13 | 276.20 | 18 | 15.25 | 650 | 178 | 2.77 / 78.71 | 2 | 4 |
| 6 | 8 | 0.44 | 165 | 15.26 | 288 | 725 | 3.50 / 79.43 | 2 | 12 |
| Average= | 3.45 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 103.32 | 28 | 15.19 | 429 | 182 | 0.18 / 72.49 | 2 | 2 |
| 2 | 7 | 2009.52 | 38 | 14.97 | 2713 | 1543 | 1.73 / 74.03 | 2 | 3 |
| 3 | 13 | 1413.76 | 18 | 15.01 | 1996 | 539 | 2.27 / 74.57 | 2 | 3 |
| 4 | 13 | 888.84 | 18 | 15.11 | 1366 | 372 | 2.64 / 74.94 | 2 | 3 |
| 5 | 13 | 312.68 | 18 | 15.23 | 685 | 188 | 2.82 / 75.13 | 2 | 4 |
| 6 | 13 | 11.04 | 18 | 15.30 | 309 | 85 | 2.91 / 75.21 | 2 | 4 |
| 7 | 8 | -0.24 | 165 | 15.26 | 286 | 720 | 3.63 / 75.93 | 2 | 13 |
| Average= | 3.45 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 107.28 | 28 | 15.22 | 434 | 185 | 0.18 / 68.97 | 2 | 2 |
| 2 | 7 | 2005.52 | 38 | 14.96 | 2702 | 1536 | 1.72 / 70.51 | 2 | 3 |
| 3 | 13 | 1350.16 | 18 | 15.04 | 1939 | 525 | 2.25 / 71.04 | 2 | 4 |
| 4 | 13 | 881.68 | 18 | 15.11 | 1290 | 351 | 2.60 / 71.39 | 2 | 4 |
| 5 | 13 | 316.20 | 18 | 15.21 | 692 | 189 | 2.79 / 71.58 | 2 | 4 |
| 6 | 8 | 0.00 | 165 | 15.24 | 289 | 727 | 3.51 / 72.30 | 2 | 13 |
| Average= | 3.44 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 107.04 | 28 | 15.22 | 436 | 186 | 0.19 / 65.50 | 2 | 2 |
| 2 | 7 | 2004.48 | 38 | 14.97 | 2691 | 1531 | 1.72 / 67.03 | 2 | 4 |
| 3 | 13 | 1309.32 | 18 | 15.06 | 1881 | 510 | 2.23 / 67.54 | 2 | 3 |
| 4 | 13 | 849.32 | 18 | 15.14 | 1317 | 359 | 2.59 / 67.90 | 2 | 5 |
| 5 | 13 | 239.36 | 18 | 15.25 | 608 | 167 | 2.75 / 68.06 | 2 | 4 |
| 6 | 8 | 0.00 | 165 | 15.27 | 288 | 726 | 3.48 / 68.79 | 2 | 11 |
| Average= | 3.44 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 108.64 | 28 | 15.22 | 442 | 188 | 0.19 / 61.94 | 2 | 2 |
| 2 | 7 | 2003.28 | 39 | 14.97 | 2711 | 1583 | 1.77 / 63.53 | 2 | 3 |
| 3 | 13 | 1392.28 | 18 | 15.05 | 1980 | 536 | 2.31 / 64.06 | 2 | 3 |
| 4 | 13 | 807.92 | 18 | 15.16 | 1238 | 338 | 2.65 / 64.40 | 2 | 4 |
| 5 | 13 | 282.64 | 18 | 15.25 | 653 | 179 | 2.82 / 64.58 | 2 | 4 |
| 6 | 8 | 0.16 | 165 | 15.27 | 291 | 733 | 3.56 / 65.31 | 2 | 16 |
| Average= | 3.44 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 107.00 | 28 | 15.23 | 436 | 186 | 0.19 / 58.43 | 2 | 2 |
| 2 | 7 | 2009.80 | 38 | 14.96 | 2715 | 1543 | 1.73 / 59.97 | 2 | 4 |
| 3 | 13 | 1341.92 | 18 | 15.05 | 1924 | 521 | 2.25 / 60.49 | 2 | 3 |
| 4 | 13 | 828.20 | 18 | 15.16 | 1242 | 339 | 2.59 / 60.83 | 2 | 3 |
| 5 | 13 | 302.72 | 18 | 15.26 | 680 | 187 | 2.78 / 61.02 | 2 | 4 |
| 6 | 8 | 0.08 | 165 | 15.28 | 291 | 734 | 3.51 / 61.75 | 2 | 14 |
| Average= | 3.43 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 109.40 | 28 | 15.24 | 440 | 188 | 0.19 / 54.83 | 2 | 2 |
| 2 | 7 | 2011.04 | 38 | 14.97 | 2721 | 1548 | 1.74 / 56.38 | 2 | 3 |
| 3 | 13 | 1398.76 | 18 | 15.06 | 1967 | 533 | 2.27 / 56.91 | 2 | 3 |
| 4 | 13 | 899.64 | 18 | 15.15 | 1310 | 357 | 2.63 / 57.27 | 2 | 5 |
| 5 | 13 | 222.36 | 18 | 15.28 | 587 | 161 | 2.79 / 57.43 | 2 | 4 |
| 6 | 13 | 28.36 | 18 | 15.31 | 330 | 91 | 2.88 / 57.52 | 2 | 4 |
| 7 | 8 | -0.16 | 165 | 15.28 | 286 | 721 | 3.60 / 58.24 | 2 | 14 |
| Average= | 3.43 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 108.92 | 29 | 15.24 | 428 | 189 | 0.19 / 51.35 | 2 | 2 |
| 2 | 3 | 975.92 | -1 | 15.55 | 1 | 0 | 0.00 / 51.35 | 2 | 2 |
| 3 | 3 | 1017.76 | 1 | 15.31 | 1575 | 24 | 0.21 / 51.37 | 2 | 3 |
| 4 | 7 | 2003.12 | 38 | 14.97 | 2687 | 1529 | 1.74 / 52.90 | 2 | 3 |
| 5 | 13 | 1350.40 | 18 | 15.08 | 1885 | 512 | 2.25 / 53.41 | 2 | 4 |
| 6 | 13 | 829.80 | 18 | 15.16 | 1240 | 338 | 2.59 / 53.75 | 2 | 4 |
| 7 | 13 | 260.60 | 18 | 15.26 | 631 | 173 | 2.77 / 53.92 | 2 | 4 |
| 8 | 8 | -0.04 | 165 | 15.28 | 286 | 721 | 3.49 / 54.64 | 2 | 9 |
| Average= | 3.42 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 108.80 | 29 | 15.24 | 436 | 193 | 0.19 / 47.81 | 2 | 2 |
| 2 | 7 | 2011.20 | 38 | 14.99 | 2704 | 1540 | 1.73 / 49.35 | 2 | 3 |
| 3 | 13 | 1360.60 | 18 | 15.07 | 1941 | 527 | 2.26 / 49.88 | 2 | 4 |
| 4 | 13 | 921.08 | 18 | 15.15 | 1356 | 370 | 2.63 / 50.25 | 2 | 5 |
| 5 | 13 | 300.08 | 18 | 15.27 | 677 | 186 | 2.82 / 50.44 | 2 | 4 |
| 6 | 8 | 0.16 | 165 | 15.29 | 286 | 722 | 3.54 / 51.16 | 2 | 12 |
| Average= | 3.41 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 111.64 | 29 | 15.25 | 438 | 194 | 0.19 / 44.28 | 2 | 3 |
| 2 | 3 | 1016.96 | 1 | 15.27 | 1598 | 24 | 0.22 / 44.31 | 2 | 3 |
| 3 | 7 | 2010.96 | 38 | 14.99 | 2723 | 1551 | 1.77 / 45.86 | 2 | 4 |
| 4 | 13 | 1396.16 | 18 | 15.07 | 1972 | 535 | 2.30 / 46.39 | 2 | 6 |
| 5 | 13 | 822.84 | 18 | 15.19 | 1232 | 337 | 2.64 / 46.73 | 2 | 4 |
| 6 | 13 | 255.12 | 18 | 15.29 | 617 | 170 | 2.81 / 46.90 | 2 | 4 |
| 7 | 8 | 0.32 | 165 | 15.30 | 286 | 722 | 3.53 / 47.62 | 2 | 12 |
| Average= | 3.40 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 109.48 | 28 | 15.24 | 434 | 185 | 0.19 / 40.73 | 2 | 2 |
| 2 | 3 | 1017.32 | 1 | 15.28 | 1509 | 23 | 0.21 / 40.75 | 2 | 2 |
| 3 | 7 | 2008.00 | 39 | 15.00 | 2720 | 1591 | 1.80 / 42.35 | 2 | 3 |
| 4 | 13 | 1399.92 | 18 | 15.09 | 1972 | 536 | 2.34 / 42.88 | 2 | 3 |
| 5 | 13 | 795.52 | 18 | 15.19 | 1184 | 324 | 2.66 / 43.21 | 2 | 3 |
| 6 | 13 | 234.44 | 18 | 15.29 | 594 | 163 | 2.82 / 43.37 | 2 | 4 |
| 7 | 8 | -0.04 | 165 | 15.31 | 285 | 720 | 3.54 / 44.09 | 2 | 13 |
| Average= | 3.39 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 108.36 | 28 | 15.25 | 424 | 181 | 0.18 / 37.26 | 2 | 2 |
| 2 | 3 | 1017.56 | 1 | 15.27 | 1601 | 24 | 0.21 / 37.28 | 2 | 3 |
| 3 | 7 | 2009.20 | 38 | 14.99 | 2695 | 1535 | 1.74 / 38.82 | 2 | 3 |
| 4 | 13 | 1305.68 | 18 | 15.09 | 1863 | 506 | 2.25 / 39.32 | 2 | 5 |
| 5 | 13 | 881.52 | 18 | 15.16 | 1277 | 348 | 2.60 / 39.67 | 2 | 3 |
| 6 | 13 | 260.52 | 18 | 15.28 | 614 | 169 | 2.76 / 39.84 | 2 | 4 |
| 7 | 8 | 0.16 | 165 | 15.30 | 280 | 707 | 3.47 / 40.55 | 2 | 12 |
| Average= | 3.38 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 107.84 | 28 | 15.25 | 423 | 181 | 0.18 / 33.76 | 2 | 3 |
| 2 | 3 | 1022.56 | 1 | 15.28 | 1605 | 25 | 0.21 / 33.79 | 2 | 2 |
| 3 | 7 | 2011.44 | 38 | 14.99 | 2699 | 1537 | 1.74 / 35.32 | 2 | 4 |
| 4 | 13 | 1338.00 | 18 | 15.08 | 1911 | 519 | 2.26 / 35.84 | 2 | 3 |
| 5 | 13 | 818.08 | 18 | 15.17 | 1228 | 335 | 2.60 / 36.18 | 2 | 3 |
| 6 | 13 | 298.20 | 18 | 15.28 | 663 | 182 | 2.78 / 36.36 | 2 | 4 |
| 7 | 8 | -0.04 | 165 | 15.30 | 283 | 714 | 3.49 / 37.08 | 2 | 13 |
| Average= | 3.37 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 108.08 | 27 | 15.25 | 436 | 180 | 0.18 / 30.23 | 2 | 2 |
| 2 | 3 | 1030.64 | 1 | 15.27 | 1530 | 23 | 0.20 / 30.25 | 2 | 4 |
| 3 | 7 | 2006.24 | 38 | 14.99 | 2695 | 1535 | 1.74 / 31.79 | 2 | 5 |
| 4 | 13 | 1391.32 | 18 | 15.06 | 2006 | 544 | 2.28 / 32.33 | 2 | 5 |
| 5 | 13 | 853.00 | 18 | 15.16 | 1272 | 347 | 2.63 / 32.68 | 2 | 3 |
| 6 | 13 | 319.56 | 18 | 15.26 | 686 | 188 | 2.82 / 32.87 | 2 | 4 |
| 7 | 8 | 0.16 | 165 | 15.30 | 283 | 714 | 3.53 / 33.58 | 2 | 13 |
| Average= | 3.36 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 104.00 | 31 | 15.26 | 420 | 199 | 0.20 / 26.01 | 2 | 3 |
| 2 | 3 | 868.32 | -3 | 15.62 | 2 | 0 | 0.00 / 26.01 | 2 | 3 |
| 3 | 7 | 2005.52 | 75 | 14.86 | 2679 | 2986 | 3.18 / 28.99 | 2 | 7 |
| 4 | 13 | 529.20 | 18 | 15.20 | 907 | 248 | 3.43 / 29.24 | 2 | 3 |
| 5 | 13 | 36.08 | 18 | 15.33 | 335 | 92 | 3.53 / 29.33 | 2 | 5 |
| 6 | 8 | 0.00 | 165 | 15.28 | 284 | 716 | 4.24 / 30.05 | 2 | 15 |
| Average= | 3.34 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 105.80 | 27 | 15.25 | 433 | 178 | 0.18 / 22.09 | 2 | 2 |
| 2 | 7 | 1807.44 | 75 | 14.93 | 2463 | 2758 | 2.94 / 24.85 | 2 | 6 |
| 3 | 13 | 479.92 | 18 | 15.24 | 865 | 237 | 3.17 / 25.09 | 2 | 3 |
| 4 | 8 | 0.20 | 165 | 15.31 | 285 | 720 | 3.89 / 25.81 | 2 | 12 |
| Average= | 3.23 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 106.76 | 26 | 15.26 | 418 | 166 | 0.17 / 18.25 | 2 | 2 |
| 2 | 3 | 1024.84 | 1 | 15.34 | 1543 | 24 | 0.19 / 18.28 | 2 | 3 |
| 3 | 7 | 1806.72 | 74 | 14.92 | 2460 | 2716 | 2.91 / 20.99 | 2 | 5 |
| 4 | 13 | 437.24 | 18 | 15.25 | 794 | 218 | 3.12 / 21.21 | 2 | 4 |
| 5 | 8 | 0.08 | 165 | 15.30 | 280 | 707 | 3.83 / 21.92 | 2 | 13 |
| Average= | 3.13 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 109.08 | 26 | 15.27 | 436 | 173 | 0.17 / 14.41 | 2 | 3 |
| 2 | 7 | 1816.52 | 74 | 14.92 | 2485 | 2744 | 2.92 / 17.16 | 2 | 5 |
| 3 | 13 | 435.12 | 18 | 15.24 | 806 | 221 | 3.14 / 17.38 | 2 | 5 |
| 4 | 8 | 0.04 | 165 | 15.30 | 281 | 709 | 3.85 / 18.09 | 2 | 15 |
| Average= | 3.01 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 105.24 | 26 | 15.27 | 425 | 169 | 0.17 / 10.96 | 2 | 3 |
| 2 | 7 | 1527.00 | 75 | 15.03 | 2131 | 2402 | 2.57 / 13.36 | 2 | 3 |
| 3 | 13 | 245.36 | 18 | 15.31 | 601 | 166 | 2.74 / 13.53 | 2 | 3 |
| 4 | 8 | 0.12 | 165 | 15.32 | 282 | 713 | 3.45 / 14.24 | 2 | 14 |
| Average= | 2.85 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 104.76 | 27 | 15.27 | 425 | 175 | 0.18 / 7.54 | 2 | 2 |
| 2 | 7 | 1526.40 | 74 | 15.04 | 2130 | 2371 | 2.55 / 9.91 | 2 | 5 |
| 3 | 13 | 286.16 | 18 | 15.30 | 640 | 176 | 2.72 / 10.09 | 2 | 4 |
| 4 | 8 | 0.08 | 165 | 15.32 | 278 | 703 | 3.42 / 10.79 | 2 | 15 |
| Average= | 2.70 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 106.28 | 33 | 15.31 | 416 | 210 | 0.21 / 4.07 | 2 | 3 |
| 2 | 3 | 778.24 | -4 | 15.64 | 2 | 0 | 0.00 / 4.07 | 2 | 3 |
| 3 | 3 | 929.16 | -1 | 15.67 | 3 | 0 | 0.00 / 4.07 | 2 | 3 |
| 4 | 7 | 1526.04 | 74 | 15.03 | 2157 | 2399 | 2.61 / 6.47 | 2 | 6 |
| 5 | 13 | 323.80 | 18 | 15.30 | 679 | 187 | 2.80 / 6.66 | 2 | 4 |
| 6 | 8 | 0.12 | 165 | 15.33 | 279 | 706 | 3.50 / 7.36 | 2 | 12 |
| Average= | 2.45 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 103.36 | 28 | 15.46 | 376 | 163 | 0.16 / 1.51 | 3 | 3 |
| 2 | 3 | 939.12 | -1 | 15.64 | 1 | 0 | 0.00 / 1.51 | 3 | 3 |
| 3 | 7 | 985.76 | 75 | 15.22 | 1446 | 1651 | 1.81 / 3.16 | 2 | 5 |
| 4 | 8 | -0.08 | 165 | 15.38 | 275 | 698 | 2.51 / 3.86 | 2 | 11 |
| Average= | 1.93 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 53.56 | 28 | 15.60 | 306 | 134 | 0.13 / 0.13 | 3 | 6 |
| 2 | 7 | 69.40 | 74 | 15.57 | 325 | 374 | 0.51 / 0.51 | 3 | 3 |
| 3 | 8 | 0.56 | 240 | 15.54 | 226 | 843 | 1.35 / 1.35 | 3 | 21 |
| Average= | 1.35 (KJ/cycle) |