SIO Argo Site:
Pump Diagnostics







Serial= 4076 - WMO= 3902543


Cycle 13 : GMT 29/ 8/2026 20: 0: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.24 550 14 14.85 368 77 0.08 / 58.67 3 3
2 10 972.16 10203 2 14.96 1429 43 0.12 / 58.71 3 3
3 3 966.52 11118 -1 15.34 1 0 0.04 / 58.71 3 3
4 6 1006.28 853632 -100 15.37 2 0 0.04 / 58.71 3 3
5 7 1478.24 860509 58 14.74 1967 1682 1.80 / 60.39 2 5
6 13 1049.52 863232 16 14.79 1505 356 2.16 / 60.75 2 7
7 13 789.56 865045 16 14.81 1207 286 2.44 / 61.03 2 8
8 13 526.12 866858 16 14.85 903 215 2.66 / 61.25 2 9
9 13 304.40 868370 16 14.88 634 151 2.81 / 61.40 3 9
10 13 73.48 869882 16 14.90 359 86 2.89 / 61.48 3 9
11 13 53.04 870034 16 14.90 336 80 2.97 / 61.56 3 10
12 13 38.48 870184 16 14.90 319 76 3.05 / 61.64 3 10
13 13 35.40 870288 16 14.90 311 74 3.12 / 61.71 3 11
14 13 12.32 870590 16 14.88 277 66 3.19 / 61.78 3 10
15 8 -0.08 870736 243 14.85 252 909 4.10 / 62.69 3 62
Average= 4.48
(KJ/cycle)

Cycle 12 : GMT 19/ 8/2026 17:54: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.68 658 13 14.88 367 71 0.07 / 54.44 3 3
2 10 1006.04 10312 2 14.95 1481 44 0.12 / 54.48 3 3
3 10 998.20 11218 2 14.96 1495 45 0.16 / 54.53 3 4
4 3 965.72 14839 -1 15.37 1 0 0.09 / 54.53 3 4
5 6 1005.04 810544 -100 15.37 1 0 0.09 / 54.53 3 4
6 7 1476.00 817109 58 14.75 1961 1678 1.84 / 56.21 2 7
7 13 1154.36 819226 16 14.80 1622 384 2.22 / 56.59 2 8
8 13 825.92 821342 16 14.82 1253 297 2.52 / 56.89 2 9
9 13 597.08 822853 16 14.84 983 233 2.75 / 57.12 2 10
10 13 280.64 824970 16 14.88 607 145 2.90 / 57.27 2 10
11 13 57.64 826438 16 14.92 343 82 2.98 / 57.35 3 10
12 13 44.08 826622 16 14.91 326 78 3.06 / 57.43 2 11
13 13 42.16 826759 16 14.91 321 77 3.13 / 57.50 3 11
14 13 35.68 827061 16 14.90 309 74 3.21 / 57.58 3 10
15 13 9.28 827362 16 14.90 271 65 3.27 / 57.64 3 11
16 8 0.00 827492 245 14.86 261 950 4.22 / 58.59 3 73
Average= 4.51
(KJ/cycle)

Cycle 11 : GMT 10/ 8/2026 3:48: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.28 551 13 14.85 358 69 0.07 / 50.36 3 3
2 3 1022.16 12625 1 15.00 1526 23 0.09 / 50.38 3 3
3 3 1017.68 16235 1 15.04 1538 23 0.12 / 50.40 2 3
4 6 1024.24 883938 -100 15.04 1538 0 0.05 / 50.40 2 3
5 7 1474.36 890316 58 14.75 1968 1684 1.80 / 52.09 2 5
6 13 1054.52 893037 16 14.80 1509 357 2.16 / 52.44 2 7
7 13 870.72 894246 16 14.81 1299 308 2.46 / 52.75 2 8
8 13 508.36 896664 16 14.87 881 210 2.67 / 52.96 2 8
9 13 252.28 898477 16 14.90 576 137 2.81 / 53.10 2 9
10 13 60.68 899749 16 14.92 348 83 2.89 / 53.18 3 9
11 13 40.36 899911 16 14.90 321 77 2.97 / 53.26 3 10
12 13 32.00 900074 16 14.90 307 73 3.04 / 53.33 3 10
13 13 26.76 900270 16 14.91 301 72 3.12 / 53.40 3 10
14 8 -0.08 900712 262 14.87 248 966 4.08 / 54.37 3 60
Average= 4.53
(KJ/cycle)

Cycle 10 : GMT 30/ 7/2026 17:22: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.04 551 15 14.85 363 81 0.08 / 44.90 3 3
2 6 1009.88 855138 -100 15.39 1 0 0.00 / 44.90 3 3
3 7 1479.24 861621 145 14.64 1952 4144 4.22 / 49.04 2 9
4 13 60.04 868103 16 14.91 352 84 4.31 / 49.12 3 10
5 13 41.40 868252 16 14.91 329 78 4.39 / 49.20 3 10
6 13 37.12 868413 16 14.91 320 76 4.46 / 49.28 3 11
7 13 13.48 868714 16 14.90 285 68 4.53 / 49.35 3 11
8 8 -0.04 868857 247 14.86 256 940 5.47 / 50.29 3 52
Average= 4.57
(KJ/cycle)

Cycle 9 : GMT 20/ 7/2026 15:49: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.36 657 15 14.87 375 84 0.08 / 39.45 3 3
2 6 1020.24 855245 -100 15.35 1 0 0.00 / 39.45 3 3
3 7 1479.44 861833 145 14.63 1947 4130 4.21 / 43.58 2 9
4 13 41.16 868299 16 14.91 328 78 4.29 / 43.66 3 10
5 13 35.92 868410 16 14.90 319 76 4.37 / 43.74 3 10
6 13 32.24 868623 16 14.90 313 75 4.44 / 43.81 3 10
7 13 13.72 868925 16 14.90 281 67 4.51 / 43.88 3 10
8 8 0.04 869103 249 14.85 254 939 5.45 / 44.82 3 53
Average= 4.48
(KJ/cycle)

Cycle 8 : GMT 10/ 7/2026 14:10: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.20 657 14 14.84 371 77 0.08 / 33.99 3 3
2 10 986.96 10311 2 14.95 1474 44 0.12 / 34.04 3 3
3 3 972.68 14835 -1 15.37 1 0 0.04 / 34.04 3 3
4 6 1020.20 853740 -100 15.37 1 0 0.04 / 34.04 3 3
5 7 1474.12 860510 145 14.65 1934 4108 4.23 / 38.15 2 8
6 13 38.76 866955 16 14.92 322 77 4.31 / 38.22 3 10
7 13 27.92 867112 16 14.91 309 74 4.38 / 38.30 3 10
8 13 24.88 867258 16 14.91 301 72 4.45 / 38.37 3 10
9 13 6.04 867560 16 14.90 272 65 4.52 / 38.43 3 11
10 8 0.08 867736 251 14.87 250 933 5.45 / 39.37 3 76
Average= 4.37
(KJ/cycle)

Cycle 7 : GMT 30/ 6/2026 12:54: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.64 548 13 14.84 360 69 0.07 / 28.51 3 3
2 10 997.76 10202 2 14.94 1478 44 0.11 / 28.55 3 3
3 6 1009.88 853629 -100 15.36 1 0 0.04 / 28.55 3 3
4 7 1472.88 860483 145 14.65 1936 4113 4.23 / 32.66 2 9
5 13 41.56 866898 16 14.92 332 79 4.31 / 32.74 3 10
6 13 31.04 867048 16 14.92 315 75 4.38 / 32.82 3 11
7 13 24.84 867192 16 14.92 303 72 4.45 / 32.89 3 12
8 13 8.56 867426 16 14.89 279 66 4.52 / 32.96 3 11
9 8 -0.04 867585 253 14.86 256 962 5.48 / 33.92 3 66
Average= 4.24
(KJ/cycle)

Cycle 6 : GMT 20/ 6/2026 11:41: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.80 656 23 14.86 373 127 0.13 / 23.04 3 3
2 3 848.44 11523 -3 15.34 1 0 0.00 / 23.04 3 3
3 3 926.76 15161 -1 15.36 2 0 0.00 / 23.04 3 3
4 6 972.68 854065 -100 15.36 2 0 0.00 / 23.04 3 3
5 7 1487.88 874564 145 14.63 1952 4141 4.27 / 27.18 2 10
6 13 45.52 881033 16 14.91 330 79 4.35 / 27.26 3 10
7 13 30.12 881180 16 14.90 308 73 4.42 / 27.33 3 10
8 13 25.24 881373 16 14.90 301 72 4.49 / 27.41 3 11
9 8 -0.12 881683 271 14.85 256 1030 5.52 / 28.44 3 60
Average= 4.06
(KJ/cycle)

Cycle 5 : GMT 10/ 6/2026 6:31: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.08 551 15 14.84 371 83 0.08 / 17.50 3 3
2 3 972.24 15031 -1 15.36 2 0 0.00 / 17.50 3 3
3 6 1009.04 54735 -100 15.36 2 0 0.00 / 17.50 3 3
4 7 1478.08 75234 145 14.63 1946 4128 4.21 / 21.63 2 10
5 13 41.44 81721 16 14.90 332 79 4.29 / 21.71 3 9
6 13 34.96 81912 16 14.89 323 77 4.37 / 21.79 3 10
7 13 20.20 82207 16 14.87 302 72 4.44 / 21.86 3 10
8 13 5.80 82409 16 14.88 281 67 4.51 / 21.93 3 9
9 8 -0.08 82565 256 14.83 260 987 5.49 / 22.91 3 64
Average= 3.82
(KJ/cycle)

Cycle 4 : GMT 9/ 6/2026 7:20: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.12 658 16 14.85 397 94 0.09 / 12.81 3 3
2 3 951.92 11524 -1 15.34 2 0 0.00 / 12.81 3 3
3 6 989.68 54840 -100 15.37 2 0 0.00 / 12.81 3 3
4 7 1114.80 56139 145 14.78 1546 3313 3.41 / 16.12 2 8
5 13 36.44 61150 16 14.92 331 79 3.49 / 16.20 3 9
6 13 30.92 61352 16 14.91 328 78 3.56 / 16.28 3 9
7 13 15.88 61654 16 14.87 304 72 3.64 / 16.35 3 9
8 8 0.08 61861 266 14.85 270 1067 4.70 / 17.42 3 54
Average= 3.48
(KJ/cycle)

Cycle 3 : GMT 8/ 6/2026 13:54: 2

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.20 658 23 14.89 398 136 0.14 / 8.07 3 3
2 3 834.52 11526 -3 15.37 1 0 0.00 / 8.07 3 3
3 3 910.12 15163 -2 15.41 1 0 0.00 / 8.07 3 3
4 6 970.48 54880 -100 15.41 1 0 0.00 / 8.07 3 3
5 7 1116.08 56457 145 14.79 1539 3300 3.44 / 11.37 2 9
6 13 45.00 61330 16 14.91 340 81 3.52 / 11.45 3 9
7 13 36.36 61485 16 14.91 336 80 3.60 / 11.53 3 10
8 13 25.40 61666 16 14.92 322 77 3.67 / 11.60 3 10
9 13 9.64 61832 16 14.90 303 72 3.75 / 11.68 3 10
10 8 0.00 61953 251 14.85 279 1040 4.79 / 12.72 3 124
Average= 3.18
(KJ/cycle)

Cycle 2 : GMT 7/ 6/2026 20:27: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.16 550 45 14.95 386 260 0.26 / 4.56 3 3
2 3 438.28 9004 -11 15.37 2 0 0.00 / 4.56 3 3
3 3 489.72 9740 -10 15.38 1 0 0.00 / 4.56 3 3
4 7 663.96 46639 145 15.00 1025 2229 2.49 / 6.79 3 9
5 13 18.80 49098 16 14.99 312 75 2.56 / 6.86 3 10
6 8 0.00 49273 247 14.93 289 1066 3.63 / 7.93 3 73
Average= 2.64
(KJ/cycle)

Cycle 1 : GMT 7/ 6/2026 6:35: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.68 657 65 15.06 347 340 0.34 / 2.21 3 3
2 3 88.56 5492 -8 15.34 1 0 0.00 / 2.21 3 3
3 3 145.48 6191 -7 15.34 2 0 0.00 / 2.21 3 3
4 7 227.04 7056 145 15.11 496 1087 1.43 / 3.29 3 5
5 8 -0.16 8126 251 15.01 267 1006 2.43 / 4.30 3 78
Average= 2.15
(KJ/cycle)

Cycle 0 : GMT 7/ 6/2026 4: 6: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.12 -99 65 15.31 348 346 0.35 / 0.35 3 3
2 7 134.28 -99 145 15.25 348 770 1.12 / 1.12 3 6
3 8 -0.12 -99 234 15.16 212 752 1.87 / 1.87 3 213
Average= 1.87
(KJ/cycle)