SIO Argo Site: Delayed Mode
Quality Control Tabulation Page



Serial= 2949 ptt= 026822 WMO= 3900806    
Return to sio-argo.ucsd.edu Return to home page
Return to Float-Type Matrix Return to Matrix of floats with similar ROM version
Raw Data Display Page Raw Profile Dispaly Page: Quad plot of profile, T/S, waterfall and trajectory
Float Diagnostics Float Diagnostics returned with each cycle by the float to monitor float health.
Float Metadata Text file of float configuration/hardware upon deployment

<-Prev Float     Next Float->


Currently Assigned Quality Control Flags
Display of the floats Delayed Mode Quality Control flags as recently reported at the GDAC.
Plot may lag the GDAC by up to 10 days
Colored circles represent the 1 (blue) to 4 (red) Argo QC scale. Dmode flags have value 0.5 greater than Rmode flags, so it easy to see which data has passed DMQC
The dots are overlain on a waterfall plot of the profile data




Temperature Salinity Plot of Quality Controlled Data
Temperature/Salinity diagram of Quality Controlled Argo profile data.
The data is color coded by QC status (Delayed Mode or Real-Time) and goodness [Argo flag 1 (good) or other (bad)].




Currently Assigned Sensor Drift Corrections
These are the drift corrections found in the Delayed Mode netcdf profile files at the GDAC. Error bars are also shown.
If no lines are shown, then the data has not yet passed through DMQC or the data is marked bad.




If present, the below figures are produced by the OW (Owens, Wong) salinity calibration software.
This software is used throughout the Argo program to access the presence of salinity drift.


OW Argo Delayed-Mode Salinity Calibration Plots
OW Diagnostic Plots for Salinity Drift Identification: Float 3900806
OW Argo Delayed-Mode Salinity Calibration Plots
Figure 1: Uncalibrated float measurements with historical estimates. (Click for larger image) Figure 2: Calibrated float measurements with historical estimates. (Click for larger image)
Figure 3: OW time series of correction, in potential conductivity (top) and salinity (bottom). (Click for larger image) Figure 4: OW time series of salinities on potential temperature levels. (Click for larger image)
Figure 5: Chosen levels in OW (Click for larger image) Figure 6: Float spatial migration and historical data locations. (Click for larger image)
OW Diagnostic Plots for Salinity Drift Identification: Float 3900806
Figure 1: Uncalibrated float measurements with historical estimates. (Click for larger image) Figure 2: Calibrated float measurements with historical estimates. (Click for larger image)
Figure 3: OW time series of correction, in potential conductivity (top) and salinity (bottom). (Click for larger image) Figure 4: OW time series of salinities on potential temperature levels. (Click for larger image)
Figure 5: Chosen levels in OW (Click for larger image) Figure 6: Float spatial migration and historical data locations. (Click for larger image)