SIO Argo Site:
Pump Diagnostics







Serial= 4044 - WMO= 2903923


Cycle 14 : GMT 8/ 3/2026 21:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 121.40 44 14.73 395 256 0.26 / 77.78 3 3
2 3 1020.56 1 14.86 1522 23 0.28 / 77.80 2 3
3 8 2011.40 58 14.34 2633 2190 2.47 / 79.99 2 4
4 14 1785.68 16 14.40 2383 549 3.02 / 80.54 2 4
5 14 1428.16 16 14.47 1961 454 3.47 / 80.99 2 6
6 14 1253.88 16 14.49 1750 406 3.88 / 81.40 2 6
7 14 984.20 16 14.55 1439 335 4.21 / 81.73 2 7
8 14 669.28 16 14.64 1064 249 4.46 / 81.98 2 8
9 14 406.96 16 14.72 743 175 4.64 / 82.16 2 8
10 14 181.76 16 14.79 454 107 4.74 / 82.26 3 7
11 14 99.12 16 14.80 350 83 4.83 / 82.35 3 7
12 14 59.76 16 14.80 302 72 4.90 / 82.42 3 7
13 14 33.08 16 14.80 267 63 4.96 / 82.48 3 7
14 9 -0.08 245 14.78 234 847 5.81 / 83.33 3 51
Average= 5.56
(KJ/cycle)

Cycle 13 : GMT 26/ 2/2026 17:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.52 45 14.70 361 239 0.24 / 71.96 3 3
2 8 2011.96 58 14.30 2623 2176 2.41 / 74.14 2 3
3 14 1652.32 16 14.38 2222 511 2.93 / 74.65 2 4
4 14 1519.64 16 14.39 2063 475 3.40 / 75.13 2 5
5 14 1169.20 16 14.47 1663 385 3.79 / 75.51 2 6
6 14 991.88 16 14.51 1453 337 4.12 / 75.85 2 7
7 14 624.40 16 14.62 1013 237 4.36 / 76.08 2 8
8 14 493.00 16 14.65 850 199 4.56 / 76.28 2 7
9 14 203.16 16 14.73 487 115 4.67 / 76.40 2 7
10 14 116.12 16 14.74 396 93 4.77 / 76.49 3 7
11 14 45.24 16 14.76 308 73 4.84 / 76.56 3 6
12 14 26.12 16 14.76 281 66 4.91 / 76.63 3 7
13 9 -0.04 249 14.74 242 888 5.79 / 77.52 3 53
Average= 5.54
(KJ/cycle)

Cycle 12 : GMT 25/ 2/2026 19:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 123.60 45 14.75 369 245 0.24 / 66.29 3 3
2 8 2006.64 58 14.26 2616 2164 2.41 / 68.45 2 4
3 14 1776.08 16 14.31 2356 539 2.95 / 68.99 2 3
4 14 1464.72 16 14.37 2001 460 3.41 / 69.45 2 4
5 14 1200.04 16 14.41 1690 390 3.80 / 69.84 2 6
6 14 928.92 16 14.51 1368 318 4.12 / 70.16 2 7
7 14 662.24 16 14.58 1056 246 4.36 / 70.40 2 7
8 14 530.68 16 14.60 893 209 4.57 / 70.61 2 8
9 14 193.80 16 14.70 468 110 4.68 / 70.72 3 7
10 14 108.76 16 14.72 363 85 4.77 / 70.81 3 7
11 14 39.64 16 14.73 275 65 4.83 / 70.87 3 6
12 9 0.04 264 14.72 219 851 5.68 / 71.72 3 51
Average= 5.52
(KJ/cycle)

Cycle 11 : GMT 25/ 2/2026 7:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.20 45 14.71 336 222 0.22 / 60.59 3 3
2 8 2008.84 58 14.33 2627 2183 2.41 / 62.77 2 3
3 14 1729.04 16 14.39 2311 532 2.94 / 63.31 2 4
4 14 1461.92 16 14.43 2001 462 3.40 / 63.77 2 5
5 14 1198.00 16 14.49 1688 391 3.79 / 64.16 2 6
6 14 925.56 16 14.55 1367 318 4.11 / 64.48 2 6
7 14 660.56 16 14.64 1050 246 4.36 / 64.72 2 7
8 14 529.68 16 14.67 892 209 4.56 / 64.93 2 8
9 14 190.36 16 14.76 468 111 4.68 / 65.04 2 7
10 14 107.84 16 14.78 363 86 4.76 / 65.13 3 7
11 14 40.48 16 14.79 277 66 4.83 / 65.20 3 6
12 9 -0.04 262 14.78 219 848 5.67 / 66.04 3 55
Average= 5.50
(KJ/cycle)

Cycle 10 : GMT 15/ 2/2026 3:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.88 45 14.77 349 232 0.23 / 55.00 3 3
2 8 2010.24 58 14.34 2623 2182 2.41 / 57.18 2 4
3 14 1735.96 16 14.40 2346 541 2.95 / 57.72 2 5
4 14 1423.04 16 14.45 1966 455 3.41 / 58.17 2 7
5 14 1243.04 16 14.47 1750 405 3.81 / 58.58 2 7
6 14 883.36 16 14.57 1335 311 4.12 / 58.89 2 8
7 14 617.72 16 14.64 1010 237 4.36 / 59.13 2 8
8 14 318.56 16 14.74 636 150 4.51 / 59.28 2 8
9 14 191.72 16 14.77 472 112 4.62 / 59.39 3 8
10 14 112.28 16 14.79 371 88 4.71 / 59.48 3 8
11 14 77.60 16 14.80 323 76 4.79 / 59.55 3 7
12 14 21.40 16 14.81 248 59 4.85 / 59.61 3 7
13 9 0.08 238 14.79 215 757 5.60 / 60.37 3 52
Average= 5.49
(KJ/cycle)

Cycle 9 : GMT 4/ 2/2026 23:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.92 45 14.78 340 226 0.23 / 49.22 3 3
2 8 2004.68 58 14.36 2626 2187 2.41 / 51.41 2 4
3 14 1738.56 16 14.41 2333 538 2.95 / 51.95 2 5
4 14 1472.24 16 14.44 2028 469 3.42 / 52.42 2 6
5 14 1297.12 16 14.47 1801 417 3.84 / 52.83 2 6
6 14 976.12 16 14.56 1431 333 4.17 / 53.17 2 7
7 14 704.92 16 14.63 1111 260 4.43 / 53.43 2 8
8 14 476.92 16 14.70 831 195 4.63 / 53.62 2 8
9 14 197.16 16 14.77 478 113 4.74 / 53.74 2 8
10 14 158.24 16 14.78 429 101 4.84 / 53.84 3 8
11 14 83.00 16 14.80 330 78 4.92 / 53.91 3 7
12 14 52.56 16 14.81 289 68 4.99 / 53.98 3 7
13 9 0.04 247 14.80 214 782 5.77 / 54.77 3 55
Average= 5.48
(KJ/cycle)

Cycle 8 : GMT 25/ 1/2026 19:25: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.20 45 14.79 340 226 0.23 / 42.21 3 3
2 8 2010.96 145 14.21 2614 5386 5.61 / 47.60 2 5
3 14 529.68 16 14.70 896 211 5.82 / 47.81 2 9
4 14 258.32 16 14.77 555 131 5.95 / 47.94 3 10
5 14 169.28 16 14.78 441 104 6.06 / 48.05 3 9
6 14 91.36 16 14.81 339 80 6.14 / 48.13 3 9
7 14 57.04 16 14.81 297 70 6.21 / 48.20 3 9
8 9 0.56 251 14.81 215 799 7.01 / 49.00 3 57
Average= 5.44
(KJ/cycle)

Cycle 7 : GMT 15/ 1/2026 15:26: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 124.52 45 14.72 365 242 0.24 / 35.23 3 3
2 8 2012.96 146 14.20 2614 5419 5.66 / 40.65 2 5
3 14 495.24 16 14.71 856 201 5.86 / 40.85 3 9
4 14 231.32 16 14.78 518 122 5.99 / 40.97 3 9
5 14 154.08 16 14.80 419 99 6.08 / 41.07 3 9
6 14 81.56 16 14.82 325 77 6.16 / 41.15 3 8
7 14 25.40 16 14.83 252 60 6.22 / 41.21 3 8
8 9 -0.04 247 14.81 213 779 7.00 / 41.99 3 50
Average= 5.25
(KJ/cycle)

Cycle 6 : GMT 5/ 1/2026 11:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 123.32 45 14.78 364 242 0.24 / 28.29 3 3
2 8 2003.28 145 14.20 2599 5351 5.59 / 33.64 2 4
3 14 495.88 16 14.68 851 200 5.79 / 33.84 2 9
4 14 234.36 16 14.75 523 123 5.92 / 33.97 3 8
5 14 157.36 16 14.78 423 100 6.02 / 34.07 3 8
6 14 82.80 16 14.79 325 77 6.09 / 34.14 3 7
7 14 22.28 16 14.80 244 58 6.15 / 34.20 3 7
8 9 0.08 251 14.79 212 787 6.94 / 34.99 3 64
Average= 5.00
(KJ/cycle)

Cycle 5 : GMT 4/ 1/2026 14: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 124.24 45 14.78 365 243 0.24 / 21.37 3 3
2 8 2001.88 145 14.21 2591 5339 5.58 / 26.71 2 4
3 14 524.64 16 14.68 893 210 5.79 / 26.92 2 10
4 14 220.20 16 14.77 500 118 5.91 / 27.04 3 8
5 14 147.88 16 14.80 408 97 6.01 / 27.13 3 8
6 14 70.84 16 14.81 309 73 6.08 / 27.21 3 7
7 14 40.40 16 14.81 267 63 6.14 / 27.27 3 7
8 9 0.04 251 14.81 210 781 6.92 / 28.05 3 59
Average= 4.67
(KJ/cycle)

Cycle 4 : GMT 3/ 1/2026 16:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 121.60 45 14.80 364 242 0.24 / 14.88 3 3
2 8 1807.60 146 14.31 2362 4935 5.18 / 19.81 2 5
3 14 470.72 16 14.71 814 192 5.37 / 20.01 2 8
4 14 236.44 16 14.78 520 123 5.49 / 20.13 2 8
5 14 151.20 16 14.79 412 97 5.59 / 20.23 3 8
6 14 76.40 16 14.80 315 75 5.66 / 20.30 3 8
7 9 0.16 264 14.81 211 825 6.49 / 21.13 3 53
Average= 4.23
(KJ/cycle)

Cycle 3 : GMT 2/ 1/2026 22:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 122.56 45 14.85 371 248 0.25 / 9.13 3 3
2 8 1536.40 145 14.46 2055 4309 4.56 / 13.44 2 5
3 14 276.76 16 14.79 572 135 4.69 / 13.57 3 7
4 14 195.00 16 14.81 466 110 4.80 / 13.68 3 8
5 14 108.68 16 14.83 356 84 4.89 / 13.77 3 6
6 14 39.24 16 14.84 266 63 4.95 / 13.83 3 6
7 9 0.52 258 14.84 211 808 5.76 / 14.64 3 55
Average= 3.66
(KJ/cycle)

Cycle 2 : GMT 2/ 1/2026 5:26: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 123.52 45 14.85 364 243 0.24 / 5.05 3 3
2 8 992.88 145 14.72 1416 3022 3.27 / 8.07 3 8
3 9 0.00 253 14.90 214 807 4.07 / 8.88 3 58
Average= 2.96
(KJ/cycle)

Cycle 1 : GMT 1/ 1/2026 14:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 121.68 65 14.95 346 336 0.34 / 2.20 3 3
2 11 534.64 3 15.00 877 39 0.38 / 2.24 3 3
3 3 572.52 2 15.01 941 28 0.40 / 2.26 3 3
4 3 558.60 2 15.01 921 28 0.43 / 2.29 3 3
5 8 539.96 145 14.87 854 1841 2.27 / 4.13 3 3
6 9 -0.24 221 14.89 205 675 2.95 / 4.81 3 245
Average= 2.40
(KJ/cycle)

Cycle 0 : GMT 1/ 1/2026 11:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 141.36 65 15.24 375 371 0.37 / 0.37 3 3
2 8 176.84 145 15.17 402 884 1.26 / 1.26 3 3
3 9 0.20 225 15.08 178 604 1.86 / 1.86 3 245
Average= 1.86
(KJ/cycle)