SIO Argo Site:
Pump Diagnostics Page   



Serial= 4036 WMO= 2903919

Return

←PreviousNext→

Cycle 8 GMT 17/ 7/2025 17: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.04 49 14.81 384 279 0.28 / 41.46 2 2
2 8 2005.84 58 14.53 2866 2415 2.69 / 43.87 2 4
3 14 1551.76 20 14.59 2299 671 3.36 / 44.55 2 6
4 14 1106.44 20 14.68 1729 508 3.87 / 45.05 2 8
5 14 822.88 20 14.74 1373 405 4.28 / 45.46 2 10
6 14 422.96 20 14.85 843 250 4.53 / 45.71 2 11
7 14 204.08 20 14.89 547 163 4.69 / 45.87 2 12
8 14 130.00 20 14.87 440 131 4.82 / 46.00 2 13
9 14 88.24 20 14.89 371 110 4.93 / 46.11 2 14
10 14 58.16 20 14.89 324 96 5.03 / 46.21 2 15
11 9 0.04 172 14.89 229 586 5.61 / 46.80 2 50
12 15 -0.12 48 14.88 179 128 5.74 / 46.92 33 248
Average= 5.21
(KJ/cycle)

Cycle 7 GMT 7/ 7/2025 12:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.64 45 14.81 383 255 0.26 / 35.25 2 2
2 11 1024.84 3 14.88 1665 74 0.33 / 35.32 2 3
3 3 1028.36 1 14.93 1692 25 0.35 / 35.35 2 3
4 3 1020.84 1 14.98 1684 25 0.38 / 35.37 2 3
5 8 2004.40 58 14.53 2850 2402 2.78 / 37.78 2 4
6 14 1635.92 20 14.57 2404 701 3.48 / 38.48 2 6
7 14 1289.32 20 14.62 1959 573 4.06 / 39.05 2 8
8 14 1112.12 20 14.64 1737 509 4.56 / 39.56 2 9
9 14 626.24 20 14.77 1113 329 4.89 / 39.89 2 11
10 14 244.00 20 14.86 604 180 5.07 / 40.07 2 12
11 14 158.64 20 14.88 482 143 5.22 / 40.21 2 13
12 14 122.68 20 14.88 430 128 5.34 / 40.34 2 16
13 14 88.04 20 14.86 376 112 5.46 / 40.45 2 16
14 9 0.04 176 14.87 233 610 6.07 / 41.06 2 51
15 15 -0.08 44 14.86 186 122 6.19 / 41.18 32 248
Average= 5.15
(KJ/cycle)

Cycle 6 GMT 27/ 6/2025 8:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.52 47 14.80 378 263 0.26 / 27.63 2 2
2 11 1002.48 2 14.93 1639 49 0.31 / 27.68 2 3
3 8 2002.56 145 14.35 2829 5886 6.20 / 33.56 2 6
4 14 468.52 16 14.79 899 213 6.41 / 33.78 2 11
5 14 191.28 16 14.87 531 126 6.54 / 33.90 2 12
6 14 152.24 16 14.86 474 113 6.65 / 34.02 2 13
7 14 131.00 16 14.87 438 104 6.75 / 34.12 2 14
8 14 106.12 16 14.86 400 95 6.85 / 34.22 2 16
9 14 34.92 16 14.86 290 69 6.92 / 34.28 2 14
10 9 -0.08 170 14.85 229 578 7.50 / 34.86 2 52
11 15 -0.20 50 14.84 177 131 7.63 / 34.99 34 248
Average= 5.00
(KJ/cycle)

Cycle 5 GMT 26/ 6/2025 11: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.04 47 14.84 366 255 0.26 / 20.64 2 3
2 3 1016.36 1 14.99 1674 25 0.28 / 20.66 2 2
3 8 1819.00 145 14.45 2591 5429 5.71 / 26.09 2 6
4 14 320.24 16 14.85 700 166 5.88 / 26.26 2 11
5 14 180.36 16 14.86 510 121 6.00 / 26.38 2 12
6 14 130.56 16 14.88 433 103 6.10 / 26.48 2 12
7 14 112.08 16 14.87 401 95 6.20 / 26.58 2 13
8 14 86.84 16 14.87 360 86 6.28 / 26.66 2 14
9 9 0.04 183 14.88 222 605 6.89 / 27.27 2 51
10 15 0.00 37 14.86 180 99 6.98 / 27.37 32 248
Average= 4.56
(KJ/cycle)

Cycle 4 GMT 25/ 6/2025 14:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.76 46 14.86 386 264 0.26 / 14.48 2 2
2 8 1526.44 145 14.59 2230 4718 4.98 / 19.20 2 7
3 14 173.32 16 14.90 498 119 5.10 / 19.32 2 11
4 14 134.16 16 14.90 442 105 5.21 / 19.42 2 12
5 14 107.84 16 14.89 404 96 5.30 / 19.52 2 14
6 14 85.04 16 14.90 364 87 5.39 / 19.60 2 15
7 14 49.08 16 14.89 306 73 5.46 / 19.68 2 15
8 9 -0.08 172 14.88 226 578 6.04 / 20.26 2 53
9 15 -0.12 48 14.88 177 126 6.17 / 20.38 34 248
Average= 4.08
(KJ/cycle)

Cycle 3 GMT 24/ 6/2025 20:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.80 46 14.87 378 259 0.26 / 10.02 2 2
2 8 1016.76 145 14.82 1571 3376 3.63 / 13.40 2 14
3 14 74.96 16 14.94 361 86 3.72 / 13.49 2 16
4 9 0.00 176 14.93 231 607 4.33 / 14.09 2 52
5 15 -0.16 44 14.91 186 122 4.45 / 14.22 33 248
Average= 3.55
(KJ/cycle)

Cycle 2 GMT 24/ 6/2025 3:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.76 45 14.85 373 249 0.25 / 5.52 2 2
2 3 1027.96 1 15.00 1687 25 0.27 / 5.54 2 3
3 3 1017.96 1 15.02 1673 25 0.30 / 5.57 2 3
4 8 1011.92 146 14.82 1567 3391 3.69 / 8.96 2 15
5 14 74.36 16 14.94 354 85 3.77 / 9.04 2 17
6 9 -0.04 172 14.92 230 590 4.37 / 9.63 2 50
7 15 -0.08 48 14.91 187 134 4.50 / 9.77 31 247
Average= 3.26
(KJ/cycle)

Cycle 1 GMT 23/ 6/2025 12:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.60 65 14.98 364 354 0.35 / 2.55 3 3
2 11 518.92 3 15.07 933 42 0.40 / 2.60 2 3
3 3 539.04 1 15.09 980 15 0.41 / 2.61 2 3
4 3 532.64 1 15.09 986 15 0.43 / 2.63 2 3
5 8 522.68 145 14.95 907 1966 2.39 / 4.59 2 11
6 9 0.32 155 14.93 221 511 2.90 / 5.10 2 51
7 15 -0.16 65 14.91 168 163 3.07 / 5.27 33 247
Average= 2.63
(KJ/cycle)

Cycle 0 GMT 23/ 6/2025 9:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 134.68 141 15.22 402 863 0.86 / 0.86 3 5
2 8 142.20 145 15.18 370 814 1.68 / 1.68 2 12
3 9 -0.12 78 15.12 194 229 1.91 / 1.91 3 52
4 15 0.08 142 15.11 137 294 2.20 / 2.20 34 247
Average= 2.20
(KJ/cycle)