SIO Argo Site:
Pump Diagnostics







Serial= 3333 - WMO= 2903847


Cycle 31 : GMT 11/ 9/2026 0: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.56 36 15.12 400 218 0.22 / 126.10 3 3
2 3 744.80 -9 15.50 1 0 0.00 / 126.10 3 3
3 3 1181.40 5 15.18 1857 141 0.36 / 126.25 3 4
4 7 2017.60 38 14.89 2817 1594 1.95 / 127.84 2 6
5 13 1577.32 18 14.92 2304 619 2.57 / 128.46 2 9
6 13 981.84 18 15.01 1555 420 2.99 / 128.88 2 11
7 13 385.64 18 15.15 774 211 3.20 / 129.09 3 9
8 13 122.00 18 15.18 425 116 3.32 / 129.21 3 9
9 13 65.36 18 15.18 348 95 3.41 / 129.30 3 10
10 8 -0.08 165 15.16 253 633 4.05 / 129.93 3 17
Average= 4.06
(KJ/cycle)

Cycle 30 : GMT 1/ 9/2026 6: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.28 35 15.12 392 207 0.21 / 121.93 3 3
2 3 788.04 -8 15.50 0 0 0.00 / 121.93 3 3
3 3 1214.44 6 15.16 1896 172 0.38 / 122.11 3 5
4 7 2007.04 38 14.91 2806 1590 1.97 / 123.70 3 6
5 13 1588.84 18 14.91 2307 619 2.59 / 124.31 2 10
6 13 1143.32 18 14.98 1758 474 3.06 / 124.79 3 12
7 13 533.04 18 15.11 950 258 3.32 / 125.05 3 10
8 13 124.68 18 15.19 428 117 3.44 / 125.16 3 8
9 13 38.16 18 15.20 309 85 3.52 / 125.25 3 9
10 8 -0.08 165 15.17 255 638 4.16 / 125.89 3 15
Average= 4.06
(KJ/cycle)

Cycle 29 : GMT 22/ 8/2026 12: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.64 35 15.13 383 203 0.20 / 117.84 3 3
2 3 792.92 -7 15.52 1 0 0.00 / 117.84 3 3
3 3 1177.68 5 15.17 1862 141 0.34 / 117.98 3 5
4 7 2008.12 38 14.91 2802 1588 1.93 / 119.56 3 6
5 13 1587.12 18 14.92 2302 618 2.55 / 120.18 2 7
6 13 1010.92 18 15.01 1591 430 2.98 / 120.61 3 12
7 13 557.88 18 15.11 985 268 3.25 / 120.88 3 10
8 13 119.48 18 15.19 429 117 3.36 / 121.00 3 9
9 13 30.16 18 15.20 303 83 3.45 / 121.08 3 10
10 8 0.00 165 15.16 258 645 4.09 / 121.73 3 18
Average= 4.06
(KJ/cycle)

Cycle 28 : GMT 12/ 8/2026 18:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.24 34 15.14 391 201 0.20 / 113.83 3 3
2 3 817.84 -7 15.51 0 0 0.00 / 113.83 3 3
3 3 1218.64 6 15.17 1888 172 0.37 / 114.00 3 7
4 7 2008.04 38 14.92 2784 1578 1.95 / 115.58 3 7
5 13 1590.68 18 14.93 2306 620 2.57 / 116.20 3 8
6 13 1003.00 18 15.01 1576 426 3.00 / 116.63 3 11
7 13 297.56 18 15.17 657 179 3.18 / 116.81 2 9
8 13 86.48 18 15.20 376 103 3.28 / 116.91 3 8
9 13 25.88 18 15.21 293 80 3.36 / 116.99 3 9
10 8 0.12 165 15.17 257 643 4.00 / 117.63 3 20
Average= 4.06
(KJ/cycle)

Cycle 27 : GMT 2/ 8/2026 23:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.04 33 15.13 402 201 0.20 / 109.74 3 3
2 3 832.20 -6 15.52 0 0 0.00 / 109.74 3 3
3 3 1194.72 6 15.17 1875 171 0.37 / 109.92 3 6
4 7 2005.48 39 14.91 2811 1635 2.01 / 111.55 3 7
5 13 1572.68 18 14.94 2295 617 2.62 / 112.17 3 9
6 13 990.68 18 15.02 1564 423 3.05 / 112.59 2 10
7 13 397.88 18 15.17 787 215 3.26 / 112.80 3 10
8 13 80.04 18 15.21 370 101 3.36 / 112.91 3 9
9 13 25.24 18 15.21 293 80 3.44 / 112.99 3 10
10 8 -0.08 165 15.18 257 644 4.09 / 113.63 3 18
Average= 4.06
(KJ/cycle)

Cycle 26 : GMT 24/ 7/2026 5:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.88 31 15.13 381 179 0.18 / 105.61 3 3
2 3 891.32 -4 15.53 0 0 0.00 / 105.61 3 3
3 3 1177.40 5 15.18 1864 141 0.32 / 105.75 3 6
4 7 2006.04 38 14.92 2805 1590 1.91 / 107.34 3 8
5 13 1580.52 18 14.94 2304 620 2.53 / 107.96 2 9
6 13 980.56 18 15.03 1548 419 2.95 / 108.38 2 11
7 13 388.44 18 15.16 773 211 3.16 / 108.59 3 11
8 13 113.28 18 15.21 420 115 3.27 / 108.70 3 9
9 13 30.28 18 15.21 304 83 3.36 / 108.79 3 10
10 8 0.08 165 15.17 257 643 4.00 / 109.43 3 16
11 14 0.08 30 15.15 252 115 4.12 / 109.54 4 21
Average= 4.06
(KJ/cycle)

Cycle 25 : GMT 14/ 7/2026 11:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.04 30 15.14 406 184 0.18 / 101.69 3 3
2 3 921.72 -3 15.51 0 0 0.00 / 101.69 3 3
3 3 1139.68 4 15.18 1821 111 0.29 / 101.80 2 7
4 7 2013.64 38 14.91 2815 1595 1.89 / 103.39 2 6
5 13 1584.04 18 14.94 2308 621 2.51 / 104.02 2 9
6 13 990.60 18 15.03 1574 426 2.94 / 104.44 2 9
7 13 279.44 18 15.19 640 175 3.11 / 104.62 3 9
8 13 85.36 18 15.22 375 103 3.21 / 104.72 3 9
9 13 24.72 18 15.21 294 80 3.29 / 104.80 3 9
10 8 0.00 165 15.18 251 629 3.92 / 105.43 3 20
Average= 4.05
(KJ/cycle)

Cycle 24 : GMT 4/ 7/2026 17:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.88 30 15.15 390 177 0.18 / 97.87 3 3
2 3 965.80 -1 15.52 0 0 0.00 / 97.87 3 3
3 3 1044.40 1 15.24 1691 26 0.20 / 97.90 3 7
4 7 2007.72 38 14.92 2810 1593 1.80 / 99.49 3 6
5 13 1579.32 18 14.93 2295 617 2.41 / 100.11 2 9
6 13 995.08 18 15.03 1564 423 2.84 / 100.53 3 10
7 13 401.76 18 15.17 788 215 3.05 / 100.75 3 10
8 13 116.44 18 15.20 422 115 3.17 / 100.86 3 9
9 8 0.04 165 15.19 257 644 3.81 / 101.50 3 19
Average= 4.06
(KJ/cycle)

Cycle 23 : GMT 24/ 6/2026 23:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.72 29 15.17 395 174 0.17 / 94.08 3 3
2 3 984.52 -1 15.53 1 0 0.00 / 94.08 3 3
3 3 1077.92 2 15.24 1705 52 0.23 / 94.13 3 4
4 7 2006.08 38 14.92 2796 1585 1.81 / 95.72 2 5
5 13 1589.56 18 14.94 2320 624 2.43 / 96.34 3 9
6 13 884.12 18 15.06 1407 381 2.82 / 96.72 2 11
7 13 453.84 18 15.15 851 232 3.05 / 96.95 3 10
8 13 89.84 18 15.21 382 105 3.15 / 97.06 3 9
9 8 0.00 165 15.18 254 636 3.79 / 97.69 3 15
Average= 4.07
(KJ/cycle)

Cycle 22 : GMT 15/ 6/2026 5:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.56 28 15.19 386 164 0.16 / 90.29 3 3
2 7 2006.16 38 14.94 2796 1587 1.75 / 91.88 3 8
3 13 1583.04 18 14.96 2289 616 2.37 / 92.49 3 10
4 13 1003.44 18 15.05 1574 426 2.79 / 92.92 2 10
5 13 293.96 18 15.21 648 177 2.97 / 93.10 3 9
6 13 90.16 18 15.24 378 104 3.08 / 93.20 3 9
7 13 21.40 18 15.24 288 79 3.15 / 93.28 3 10
8 8 0.16 165 15.20 249 624 3.78 / 93.90 3 19
Average= 4.08
(KJ/cycle)

Cycle 21 : GMT 5/ 6/2026 11:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.08 29 15.17 392 172 0.17 / 85.99 3 3
2 7 2009.24 74 14.79 2792 3056 3.23 / 89.05 2 9
3 13 469.68 18 15.19 873 239 3.47 / 89.28 3 9
4 13 107.84 18 15.26 406 112 3.58 / 89.40 3 9
5 13 58.60 18 15.24 338 93 3.67 / 89.49 3 9
6 8 -0.16 165 15.22 254 638 4.31 / 90.13 3 15
Average= 4.10
(KJ/cycle)

Cycle 20 : GMT 26/ 5/2026 14:35:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.16 29 15.18 397 175 0.17 / 81.41 3 3
2 7 2005.44 74 14.80 2796 3062 3.24 / 84.47 3 9
3 13 544.04 18 15.17 956 261 3.50 / 84.73 3 10
4 13 113.44 18 15.25 417 114 3.61 / 84.85 3 9
5 13 29.40 18 15.25 293 80 3.69 / 84.93 3 10
6 8 -0.12 165 15.22 255 640 4.33 / 85.57 3 18
7 14 -0.12 65 15.19 251 248 4.58 / 85.82 6 121
Average= 4.09
(KJ/cycle)

Cycle 19 : GMT 16/ 5/2026 17:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.12 29 15.19 397 175 0.17 / 77.07 3 3
2 7 2005.32 74 14.81 2793 3061 3.24 / 80.13 2 9
3 13 558.96 18 15.18 981 268 3.50 / 80.40 3 11
4 13 125.84 18 15.25 433 119 3.62 / 80.51 3 9
5 13 38.72 18 15.25 312 86 3.71 / 80.60 3 10
6 8 0.36 165 15.22 253 635 4.34 / 81.24 3 20
Average= 4.06
(KJ/cycle)

Cycle 18 : GMT 6/ 5/2026 20:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.88 29 15.18 392 173 0.17 / 72.73 3 3
2 7 2006.88 74 14.81 2797 3065 3.24 / 75.80 3 8
3 13 537.88 18 15.19 949 259 3.50 / 76.06 3 11
4 13 113.64 18 15.27 419 115 3.61 / 76.17 3 9
5 13 32.68 18 15.28 300 83 3.70 / 76.26 3 10
6 8 0.16 165 15.24 253 636 4.33 / 76.89 3 19
Average= 4.05
(KJ/cycle)

Cycle 17 : GMT 27/ 4/2026 0:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.20 29 15.18 397 175 0.17 / 68.40 3 3
2 7 2004.96 74 14.82 2788 3058 3.23 / 71.45 3 8
3 13 562.84 18 15.18 992 271 3.50 / 71.72 3 10
4 13 125.28 18 15.26 428 118 3.62 / 71.84 3 9
5 13 42.00 18 15.25 311 85 3.71 / 71.93 3 10
6 8 0.20 165 15.24 252 634 4.34 / 72.56 3 17
Average= 4.03
(KJ/cycle)

Cycle 16 : GMT 17/ 4/2026 3:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.08 29 15.18 393 173 0.17 / 64.07 3 3
2 7 2005.12 74 14.81 2789 3057 3.23 / 67.13 2 8
3 13 540.44 18 15.18 956 261 3.49 / 67.39 3 12
4 13 117.56 18 15.25 421 116 3.61 / 67.50 3 9
5 13 40.80 18 15.26 311 85 3.69 / 67.59 3 10
6 8 0.00 165 15.22 252 633 4.32 / 68.22 3 20
Average= 4.01
(KJ/cycle)

Cycle 15 : GMT 7/ 4/2026 6:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.72 29 15.20 380 168 0.17 / 59.74 3 3
2 7 2008.92 74 14.82 2790 3060 3.23 / 62.80 3 9
3 13 565.76 18 15.18 1003 274 3.50 / 63.07 3 10
4 13 131.44 18 15.26 437 120 3.62 / 63.19 3 9
5 13 45.44 18 15.26 313 86 3.71 / 63.28 3 9
6 8 0.12 165 15.23 247 621 4.33 / 63.90 3 18
Average= 3.99
(KJ/cycle)

Cycle 14 : GMT 28/ 3/2026 9:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.96 28 15.18 402 171 0.17 / 55.41 3 3
2 7 2018.76 74 14.82 2799 3070 3.24 / 58.48 2 9
3 13 546.76 18 15.19 965 264 3.50 / 58.74 2 9
4 13 119.72 18 15.27 422 116 3.62 / 58.86 3 9
5 13 39.88 18 15.27 305 84 3.70 / 58.94 3 9
6 8 0.00 165 15.25 249 627 4.33 / 59.57 3 17
Average= 3.97
(KJ/cycle)

Cycle 13 : GMT 18/ 3/2026 12:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.68 28 15.18 383 163 0.16 / 51.05 3 3
2 7 2015.52 75 14.83 2806 3121 3.28 / 54.17 3 8
3 13 436.24 18 15.23 831 228 3.51 / 54.40 3 9
4 13 137.04 18 15.27 447 123 3.63 / 54.52 3 9
5 13 40.08 18 15.27 312 86 3.72 / 54.61 3 9
6 8 0.04 165 15.24 250 629 4.35 / 55.24 3 17
Average= 3.95
(KJ/cycle)

Cycle 12 : GMT 8/ 3/2026 15:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.92 28 15.19 390 166 0.17 / 46.41 3 3
2 7 2019.32 74 14.83 2802 3075 3.24 / 49.48 2 9
3 13 684.76 18 15.16 1137 310 3.55 / 49.79 3 10
4 13 116.32 18 15.27 415 114 3.67 / 49.91 3 9
5 13 62.44 18 15.27 341 94 3.76 / 50.00 3 10
6 8 0.08 165 15.24 249 626 4.39 / 50.63 3 20
7 14 0.08 69 15.21 248 260 4.65 / 50.89 8 127
Average= 3.91
(KJ/cycle)

Cycle 11 : GMT 26/ 2/2026 18:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.88 28 15.21 386 164 0.16 / 42.09 3 3
2 7 2016.88 74 14.83 2798 3071 3.23 / 45.16 3 10
3 13 548.64 18 15.19 962 263 3.50 / 45.42 3 10
4 13 121.68 18 15.27 417 115 3.61 / 45.53 3 9
5 13 35.08 18 15.28 299 82 3.69 / 45.62 3 9
6 8 0.12 165 15.25 249 627 4.32 / 46.24 3 18
Average= 3.85
(KJ/cycle)

Cycle 10 : GMT 16/ 2/2026 21:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.80 28 15.22 385 164 0.16 / 37.75 3 3
2 7 2005.68 75 14.83 2785 3098 3.26 / 40.85 2 8
3 13 530.48 18 15.22 936 256 3.52 / 41.10 2 10
4 13 116.72 18 15.28 412 113 3.63 / 41.22 3 9
5 13 33.60 18 15.28 301 83 3.71 / 41.30 3 10
6 8 -0.04 165 15.25 247 622 4.34 / 41.92 3 20
Average= 3.81
(KJ/cycle)

Cycle 9 : GMT 7/ 2/2026 1: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.32 27 15.22 386 159 0.16 / 33.46 3 3
2 3 1045.00 1 15.31 1667 26 0.18 / 33.49 3 4
3 7 2006.04 74 14.84 2777 3050 3.23 / 36.54 3 9
4 13 417.28 18 15.23 796 218 3.45 / 36.76 2 9
5 13 128.72 18 15.28 433 119 3.57 / 36.88 3 9
6 13 35.16 18 15.29 303 83 3.65 / 36.96 3 9
7 8 -0.04 165 15.26 249 627 4.28 / 37.59 3 17
Average= 3.76
(KJ/cycle)

Cycle 8 : GMT 28/ 1/2026 4:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.96 26 15.22 368 146 0.15 / 29.16 3 3
2 3 1043.96 1 15.32 1656 25 0.17 / 29.18 3 3
3 7 2005.00 74 14.85 2769 3043 3.21 / 32.23 3 8
4 13 541.88 18 15.21 950 260 3.47 / 32.49 3 9
5 13 123.88 18 15.28 423 116 3.59 / 32.60 3 8
6 13 33.48 18 15.28 296 81 3.67 / 32.69 3 9
7 8 0.12 165 15.26 246 619 4.29 / 33.30 3 15
Average= 3.70
(KJ/cycle)

Cycle 7 : GMT 18/ 1/2026 7:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.88 33 15.23 383 192 0.19 / 24.64 3 3
2 3 790.72 -4 15.63 0 0 0.00 / 24.64 3 3
3 3 933.52 -1 15.67 0 0 0.00 / 24.64 3 3
4 7 2004.48 74 14.87 2771 3049 3.24 / 27.68 2 9
5 13 550.44 18 15.22 950 260 3.50 / 27.94 3 9
6 13 139.28 18 15.29 429 118 3.62 / 28.06 3 9
7 13 41.76 18 15.31 299 82 3.70 / 28.15 3 9
8 8 0.08 165 15.27 242 610 4.31 / 28.75 3 16
9 14 0.08 71 15.25 239 259 4.57 / 29.01 3 115
Average= 3.63
(KJ/cycle)

Cycle 6 : GMT 8/ 1/2026 10:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.00 27 15.21 382 157 0.16 / 20.62 3 3
2 7 1821.28 74 14.92 2556 2822 2.98 / 23.44 3 8
3 13 384.40 18 15.25 753 207 3.19 / 23.65 3 9
4 13 121.48 18 15.29 417 115 3.30 / 23.76 3 9
5 13 33.56 18 15.30 289 80 3.38 / 23.84 3 9
6 8 0.00 165 15.27 238 600 3.98 / 24.44 3 16
Average= 3.49
(KJ/cycle)

Cycle 5 : GMT 7/ 1/2026 9:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.08 26 15.22 405 160 0.16 / 16.36 3 3
2 3 1038.40 1 15.33 1661 25 0.19 / 16.38 3 3
3 7 1821.48 74 14.93 2547 2814 3.00 / 19.20 2 8
4 13 404.76 18 15.25 777 213 3.21 / 19.41 3 9
5 13 128.60 18 15.29 426 117 3.33 / 19.53 3 9
6 13 39.60 18 15.30 297 82 3.41 / 19.61 3 9
7 8 0.16 165 15.26 240 604 4.02 / 20.21 3 18
8 14 0.16 71 15.24 231 250 4.27 / 20.46 4 137
Average= 3.41
(KJ/cycle)

Cycle 4 : GMT 6/ 1/2026 8:39: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.56 26 15.23 368 146 0.15 / 12.19 3 3
2 3 1031.64 1 15.33 1656 25 0.17 / 12.22 3 3
3 7 1815.92 74 14.93 2541 2807 2.98 / 15.02 3 9
4 13 264.00 18 15.29 593 163 3.14 / 15.19 3 9
5 13 92.36 18 15.30 363 100 3.24 / 15.29 3 8
6 13 25.88 18 15.30 273 75 3.32 / 15.36 3 8
7 8 -0.08 165 15.27 235 592 3.91 / 15.95 3 19
8 14 -0.08 69 15.24 232 244 4.15 / 16.20 5 106
Average= 3.24
(KJ/cycle)

Cycle 3 : GMT 5/ 1/2026 7:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.12 21 15.24 386 124 0.12 / 7.83 3 3
2 10 1062.60 3 15.27 1687 77 0.20 / 7.90 3 4
3 3 1100.00 3 15.28 1773 81 0.28 / 7.99 3 5
4 7 1816.92 74 14.91 2551 2815 3.10 / 10.80 3 8
5 13 281.00 18 15.27 633 174 3.27 / 10.97 3 8
6 13 97.68 18 15.29 385 106 3.38 / 11.08 3 8
7 13 27.44 18 15.29 285 78 3.46 / 11.16 3 9
8 8 0.00 165 15.26 245 617 4.07 / 11.78 3 20
9 14 0.00 73 15.23 241 268 4.34 / 12.04 5 151
Average= 3.01
(KJ/cycle)

Cycle 2 : GMT 4/ 1/2026 6:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.04 35 15.26 374 200 0.20 / 4.30 3 3
2 3 682.40 -6 15.64 0 0 0.00 / 4.30 3 3
3 3 799.16 -4 15.65 0 0 0.00 / 4.30 3 3
4 7 1520.24 74 15.03 2187 2432 2.63 / 6.73 3 10
5 13 310.96 18 15.29 662 182 2.81 / 6.92 3 9
6 13 93.52 18 15.30 376 104 2.92 / 7.02 3 9
7 13 26.60 18 15.30 281 77 3.00 / 7.10 3 10
8 8 0.00 165 15.27 241 607 3.60 / 7.70 3 17
Average= 2.57
(KJ/cycle)

Cycle 1 : GMT 3/ 1/2026 6:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.88 30 15.38 352 162 0.16 / 1.71 3 3
2 3 825.56 -3 15.63 1 0 0.00 / 1.71 3 3
3 3 911.08 -2 15.65 0 0 0.00 / 1.71 3 3
4 7 968.76 75 15.20 1491 1700 1.86 / 3.41 3 10
5 13 36.36 18 15.37 293 81 1.94 / 3.49 3 9
6 8 -0.04 165 15.33 242 612 2.56 / 4.10 3 18
Average= 2.05
(KJ/cycle)

Cycle 0 : GMT 2/ 1/2026 20: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 163.08 30 15.55 454 212 0.21 / 0.21 3 3
2 7 179.60 74 15.51 464 533 0.74 / 0.74 3 6
3 8 0.28 240 15.47 216 802 1.55 / 1.55 3 28
Average= 1.55