SIO Argo Site:
Pump Diagnostics Page   



Serial= 4023 WMO= 2903829

Return

←PreviousNext→

Cycle 22 GMT 12/ 9/2025 10:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.24 49 14.76 371 268 0.27 / 134.11 2 3
2 8 2013.28 58 14.48 2739 2300 2.57 / 136.41 2 3
3 14 1721.84 25 14.49 2398 869 3.44 / 137.28 2 4
4 14 1463.56 25 14.53 2081 756 4.19 / 138.03 2 4
5 14 1071.92 25 14.61 1609 588 4.78 / 138.62 2 5
6 14 531.56 25 14.76 938 346 5.13 / 138.97 2 6
7 14 205.72 25 14.83 522 194 5.32 / 139.16 2 7
8 14 106.44 25 14.83 390 145 5.47 / 139.31 2 7
9 14 34.04 25 14.82 286 106 5.57 / 139.41 2 8
10 9 -0.08 195 14.79 228 658 6.23 / 140.07 2 52
11 15 0.08 25 14.77 207 76 6.31 / 140.15 33 248
Average= 6.09
(KJ/cycle)

Cycle 21 GMT 2/ 9/2025 7: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.08 49 14.75 373 270 0.27 / 127.83 2 3
2 8 2008.24 58 14.47 2734 2295 2.56 / 130.12 2 3
3 14 1806.08 25 14.47 2499 904 3.47 / 131.03 2 4
4 14 1493.84 25 14.50 2129 772 4.24 / 131.80 2 5
5 14 956.44 25 14.65 1469 538 4.78 / 132.34 2 6
6 14 489.36 25 14.79 884 327 5.10 / 132.66 2 6
7 14 182.08 25 14.84 493 183 5.29 / 132.85 2 7
8 14 102.92 25 14.84 383 142 5.43 / 132.99 2 7
9 14 63.88 25 14.81 326 121 5.55 / 133.11 2 7
10 9 0.20 195 14.79 228 658 6.21 / 133.77 2 51
11 15 -0.12 25 14.77 204 75 6.28 / 133.84 31 248
Average= 6.08
(KJ/cycle)

Cycle 20 GMT 23/ 8/2025 3:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.72 49 14.75 369 267 0.27 / 121.65 2 3
2 8 2006.40 59 14.49 2730 2334 2.60 / 123.98 2 3
3 14 1701.92 25 14.50 2376 861 3.46 / 124.84 2 4
4 14 1388.96 25 14.54 1997 726 4.19 / 125.57 2 5
5 14 815.36 25 14.71 1299 478 4.67 / 126.05 2 5
6 14 500.56 25 14.78 901 333 5.00 / 126.38 2 6
7 14 183.88 25 14.84 495 184 5.18 / 126.56 2 7
8 14 94.92 25 14.84 374 139 5.32 / 126.70 2 7
9 14 63.24 25 14.82 326 121 5.44 / 126.82 2 8
10 9 0.04 193 14.80 229 654 6.10 / 127.48 2 52
11 15 -0.12 27 14.78 203 81 6.18 / 127.56 31 248
Average= 6.07
(KJ/cycle)

Cycle 19 GMT 12/ 8/2025 23:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.32 49 14.75 371 268 0.27 / 115.30 2 3
2 8 2010.48 58 14.49 2734 2298 2.57 / 117.60 2 3
3 14 1705.80 25 14.50 2376 861 3.43 / 118.46 2 4
4 14 1498.36 25 14.52 2132 774 4.20 / 119.23 2 4
5 14 1073.12 25 14.62 1613 590 4.79 / 119.82 2 6
6 14 585.68 25 14.75 1007 371 5.16 / 120.19 2 6
7 14 205.12 25 14.83 521 193 5.36 / 120.39 2 7
8 14 117.80 25 14.83 404 150 5.50 / 120.54 2 7
9 14 48.20 25 14.81 303 112 5.62 / 120.65 2 7
10 9 0.12 195 14.80 228 658 6.28 / 121.31 2 53
11 15 -0.04 25 14.78 206 76 6.35 / 121.38 30 248
Average= 6.07
(KJ/cycle)

Cycle 18 GMT 2/ 8/2025 19:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.76 49 14.78 370 268 0.27 / 109.03 2 3
2 8 2005.56 58 14.50 2727 2293 2.56 / 111.33 2 3
3 14 1753.32 25 14.51 2440 885 3.45 / 112.21 2 3
4 14 1545.52 25 14.51 2184 792 4.24 / 113.00 2 4
5 14 914.88 25 14.69 1416 520 4.76 / 113.52 2 5
6 14 454.88 25 14.81 843 312 5.07 / 113.84 2 6
7 14 192.12 25 14.85 506 188 5.26 / 114.02 2 7
8 14 110.16 25 14.84 394 146 5.40 / 114.17 2 7
9 14 71.40 25 14.82 338 125 5.53 / 114.29 2 7
10 9 0.00 195 14.80 229 661 6.19 / 114.96 2 55
11 15 -0.12 25 14.78 203 75 6.27 / 115.03 30 248
Average= 6.05
(KJ/cycle)

Cycle 17 GMT 23/ 7/2025 15:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.36 48 14.76 364 258 0.26 / 102.76 2 3
2 11 1007.28 2 14.95 1575 47 0.30 / 102.80 2 3
3 8 2010.76 58 14.51 2738 2304 2.61 / 105.11 2 3
4 14 1809.92 25 14.50 2503 907 3.52 / 106.02 2 3
5 14 1294.16 25 14.60 1882 687 4.20 / 106.70 2 5
6 14 882.76 25 14.70 1376 506 4.71 / 107.21 2 5
7 14 553.68 25 14.78 966 357 5.07 / 107.57 2 6
8 14 217.04 25 14.85 540 200 5.27 / 107.77 2 7
9 14 117.20 25 14.85 406 151 5.42 / 107.92 2 7
10 14 43.68 25 14.82 300 111 5.53 / 108.03 2 7
11 9 0.00 193 14.81 229 655 6.18 / 108.68 2 52
12 15 0.00 27 14.79 204 81 6.26 / 108.76 33 248
Average= 6.04
(KJ/cycle)

Cycle 16 GMT 14/ 7/2025 0: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.84 49 14.72 363 262 0.26 / 96.40 2 3
2 8 2007.44 58 14.51 2734 2301 2.56 / 98.70 2 3
3 14 1752.96 25 14.52 2437 885 3.45 / 99.58 2 3
4 14 1549.16 25 14.51 2196 797 4.24 / 100.38 2 4
5 14 1039.80 25 14.65 1572 576 4.82 / 100.95 2 5
6 14 595.80 25 14.77 1022 377 5.20 / 101.33 2 6
7 14 166.44 25 14.86 473 176 5.37 / 101.51 2 7
8 14 88.68 25 14.84 365 135 5.51 / 101.64 2 7
9 14 50.24 25 14.84 310 115 5.62 / 101.76 2 7
10 9 -0.20 195 14.82 230 665 6.29 / 102.42 2 50
11 15 -0.20 25 14.80 207 77 6.36 / 102.50 31 248
Average= 6.03
(KJ/cycle)

Cycle 15 GMT 3/ 7/2025 12:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.96 49 14.79 366 265 0.27 / 90.13 2 3
2 8 2004.24 58 14.50 2721 2288 2.55 / 92.42 2 3
3 14 1801.04 25 14.49 2495 904 3.46 / 93.32 2 4
4 14 1430.64 25 14.55 2047 745 4.20 / 94.07 2 4
5 14 942.88 25 14.68 1447 531 4.73 / 94.60 2 5
6 14 465.04 25 14.81 857 317 5.05 / 94.91 2 6
7 14 159.76 25 14.86 468 174 5.22 / 95.09 2 7
8 14 76.72 25 14.85 350 130 5.35 / 95.22 2 7
9 14 48.96 25 14.85 308 114 5.47 / 95.33 2 7
10 14 22.80 25 14.83 266 99 5.57 / 95.43 2 9
11 9 0.00 172 14.81 226 576 6.14 / 96.01 2 57
12 15 -0.12 48 14.80 182 129 6.27 / 96.14 32 248
Average= 6.01
(KJ/cycle)

Cycle 14 GMT 23/ 6/2025 8:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.96 49 14.78 368 267 0.27 / 83.92 2 3
2 8 2006.96 58 14.52 2724 2294 2.56 / 86.22 2 3
3 14 1661.00 25 14.56 2327 847 3.41 / 87.06 2 4
4 14 1455.00 25 14.55 2072 754 4.16 / 87.82 2 4
5 14 917.16 25 14.70 1419 521 4.68 / 88.34 2 6
6 14 498.68 25 14.81 894 331 5.01 / 88.67 2 6
7 14 137.96 25 14.87 436 162 5.18 / 88.83 2 6
8 14 68.76 25 14.87 339 126 5.30 / 88.96 2 6
9 14 49.04 25 14.85 304 113 5.41 / 89.07 2 7
10 14 20.20 25 14.84 259 96 5.51 / 89.17 2 8
11 9 -0.08 170 14.82 223 562 6.07 / 89.73 2 53
12 15 -0.08 50 14.81 181 134 6.21 / 89.86 33 248
Average= 5.99
(KJ/cycle)

Cycle 13 GMT 13/ 6/2025 4:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.12 49 14.75 374 270 0.27 / 77.71 2 3
2 8 2007.04 58 14.53 2728 2299 2.57 / 80.00 2 3
3 14 1858.52 25 14.51 2555 927 3.50 / 80.93 2 3
4 14 1372.40 25 14.59 1973 720 4.22 / 81.65 2 4
5 14 863.96 25 14.72 1349 496 4.71 / 82.15 2 5
6 14 416.68 25 14.84 787 292 5.00 / 82.44 2 6
7 14 165.52 25 14.88 468 174 5.18 / 82.61 2 6
8 14 81.28 25 14.87 354 132 5.31 / 82.74 2 7
9 14 51.00 25 14.86 308 114 5.42 / 82.86 2 7
10 14 17.84 25 14.84 258 96 5.52 / 82.95 2 8
11 9 0.24 170 14.83 224 565 6.08 / 83.52 2 56
12 15 -0.04 50 14.81 185 137 6.22 / 83.66 31 248
Average= 5.98
(KJ/cycle)

Cycle 12 GMT 3/ 6/2025 0:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.00 48 14.78 375 266 0.27 / 71.32 2 3
2 8 2006.88 58 14.54 2732 2304 2.57 / 73.62 2 3
3 14 1754.84 25 14.55 2447 890 3.46 / 74.51 2 4
4 14 1492.24 25 14.54 2120 771 4.23 / 75.28 2 4
5 14 947.92 25 14.69 1457 535 4.77 / 75.82 2 5
6 14 572.40 25 14.79 990 366 5.13 / 76.18 2 6
7 14 179.76 25 14.86 490 182 5.31 / 76.37 2 6
8 14 89.60 25 14.87 370 138 5.45 / 76.50 2 7
9 14 62.04 25 14.86 329 122 5.57 / 76.63 2 8
10 14 25.08 25 14.83 269 100 5.67 / 76.73 2 9
11 9 0.04 168 14.82 227 565 6.24 / 77.29 2 52
12 15 0.04 52 14.80 186 143 6.38 / 77.43 32 247
Average= 5.96
(KJ/cycle)

Cycle 11 GMT 23/ 5/2025 20:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.72 48 14.73 372 263 0.26 / 65.05 2 3
2 8 2010.60 58 14.53 2734 2304 2.57 / 67.36 2 3
3 14 1756.48 25 14.54 2436 885 3.45 / 68.24 2 3
4 14 1393.44 25 14.58 2010 733 4.19 / 68.97 2 4
5 14 917.00 25 14.70 1418 521 4.71 / 69.50 2 5
6 14 495.16 25 14.81 890 330 5.04 / 69.83 2 6
7 14 173.36 25 14.87 478 178 5.21 / 70.00 2 6
8 14 89.36 25 14.87 365 136 5.35 / 70.14 2 7
9 14 57.56 25 14.86 315 117 5.47 / 70.26 2 7
10 14 20.00 25 14.85 260 97 5.56 / 70.35 2 9
11 9 0.16 168 14.83 224 558 6.12 / 70.91 2 50
12 15 -0.20 52 14.82 185 143 6.26 / 71.05 31 248
Average= 5.92
(KJ/cycle)

Cycle 10 GMT 13/ 5/2025 16:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.24 48 14.87 367 262 0.26 / 58.74 2 3
2 8 2005.92 58 14.54 2735 2306 2.57 / 61.04 2 3
3 14 1858.36 25 14.52 2562 930 3.50 / 61.97 2 3
4 14 1336.60 25 14.61 1929 705 4.20 / 62.68 2 4
5 14 1033.44 25 14.66 1559 571 4.77 / 63.25 2 5
6 14 449.12 25 14.82 832 308 5.08 / 63.56 2 6
7 14 172.12 25 14.86 480 178 5.26 / 63.73 2 6
8 14 84.24 25 14.87 362 135 5.40 / 63.87 2 7
9 14 57.44 25 14.85 318 118 5.51 / 63.99 2 7
10 14 17.80 25 14.85 258 96 5.61 / 64.08 2 8
11 9 0.12 168 14.82 227 565 6.17 / 64.65 2 54
12 15 -0.04 52 14.81 184 142 6.32 / 64.79 33 248
Average= 5.89
(KJ/cycle)

Cycle 9 GMT 4/ 5/2025 1: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.96 48 14.75 422 299 0.30 / 55.29 2 3
2 11 1000.16 2 14.96 1627 49 0.35 / 55.34 2 3
3 8 1010.36 58 14.95 1563 1355 1.70 / 56.70 2 4
4 14 670.76 25 14.96 1154 432 2.13 / 57.13 2 5
5 14 178.52 25 14.99 541 203 2.34 / 57.33 2 6
6 14 89.48 25 14.98 424 159 2.50 / 57.49 2 6
7 14 61.64 25 14.96 386 144 2.64 / 57.63 2 6
8 14 24.24 25 14.93 333 124 2.76 / 57.76 2 7
9 9 0.04 174 14.93 226 587 3.35 / 58.35 2 52
10 15 0.00 46 14.91 186 128 3.48 / 58.47 31 248
Average= 5.85
(KJ/cycle)

Cycle 8 GMT 23/ 4/2025 17:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.12 48 14.79 431 306 0.31 / 47.45 2 3
2 8 2008.40 145 14.39 2761 5761 6.07 / 53.21 2 4
3 14 504.44 25 14.80 945 350 6.42 / 53.56 2 6
4 14 177.48 25 14.86 532 198 6.61 / 53.76 2 6
5 14 89.04 25 14.85 418 155 6.77 / 53.91 2 6
6 14 60.80 25 14.84 377 140 6.91 / 54.05 2 7
7 14 21.16 25 14.83 320 119 7.03 / 54.17 2 8
8 9 -0.04 172 14.81 267 680 7.71 / 54.85 2 51
9 15 -0.04 48 14.79 200 142 7.85 / 54.99 32 248
Average= 6.11
(KJ/cycle)

Cycle 7 GMT 22/ 4/2025 18: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.52 48 14.81 367 261 0.26 / 40.01 2 3
2 8 2006.08 145 14.41 2710 5662 5.92 / 45.67 2 4
3 14 486.32 25 14.83 874 324 6.25 / 46.00 2 6
4 14 115.60 25 14.91 397 148 6.40 / 46.15 2 6
5 14 82.88 25 14.90 349 130 6.53 / 46.28 2 6
6 14 56.84 25 14.88 308 115 6.64 / 46.39 2 6
7 9 0.08 198 14.85 233 685 7.32 / 47.07 2 54
8 15 -0.04 22 14.83 212 69 7.39 / 47.14 34 248
Average= 5.89
(KJ/cycle)

Cycle 6 GMT 21/ 4/2025 18:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.64 48 14.80 370 263 0.26 / 32.98 2 3
2 8 1909.20 146 14.46 2595 5478 5.74 / 38.45 2 4
3 14 271.32 25 14.89 596 222 5.96 / 38.68 2 5
4 14 103.04 25 14.91 376 140 6.10 / 38.82 2 6
5 14 78.28 25 14.89 340 127 6.23 / 38.94 2 6
6 14 39.84 25 14.88 282 105 6.33 / 39.05 2 6
7 9 0.12 195 14.86 217 629 6.96 / 39.68 2 57
8 15 -0.08 25 14.85 196 73 7.04 / 39.75 35 248
Average= 5.68
(KJ/cycle)

Cycle 5 GMT 20/ 4/2025 19:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.60 49 14.81 363 263 0.26 / 25.83 2 3
2 8 1920.28 145 14.46 2610 5472 5.74 / 31.30 2 4
3 14 430.68 25 14.86 798 296 6.03 / 31.60 2 6
4 14 134.48 25 14.90 418 156 6.19 / 31.75 2 6
5 14 85.16 25 14.89 355 132 6.32 / 31.89 2 6
6 14 57.48 25 14.88 310 115 6.44 / 32.00 2 7
7 9 0.04 195 14.86 220 637 7.07 / 32.64 2 56
8 15 -0.04 25 14.83 199 74 7.15 / 32.71 34 248
Average= 5.45
(KJ/cycle)

Cycle 4 GMT 19/ 4/2025 20:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.68 47 14.80 423 294 0.29 / 19.04 2 3
2 11 1000.76 2 14.98 1604 48 0.34 / 19.09 2 3
3 8 1712.36 146 14.56 2407 5117 5.46 / 24.21 2 4
4 14 260.60 25 14.90 635 237 5.70 / 24.44 2 6
5 14 105.24 25 14.92 428 160 5.86 / 24.60 2 6
6 14 81.40 25 14.90 387 144 6.00 / 24.75 2 5
7 14 52.00 25 14.87 341 127 6.13 / 24.88 2 6
8 9 -0.04 195 14.86 214 620 6.75 / 25.50 2 56
9 15 -0.04 25 14.84 193 72 6.82 / 25.57 33 248
Average= 5.11
(KJ/cycle)

Cycle 3 GMT 18/ 4/2025 22:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.72 45 14.83 356 238 0.24 / 12.25 2 3
2 11 1000.32 3 14.99 1562 70 0.31 / 12.32 2 3
3 8 1723.96 145 14.57 2365 4996 5.30 / 17.31 2 4
4 14 261.48 25 14.91 575 214 5.52 / 17.53 2 5
5 14 101.20 25 14.93 366 137 5.66 / 17.66 2 5
6 14 71.64 25 14.91 320 119 5.77 / 17.78 2 6
7 14 34.08 25 14.90 264 98 5.87 / 17.88 2 6
8 9 0.12 195 14.86 268 777 6.65 / 18.66 2 51
9 15 -0.04 25 14.82 246 91 6.74 / 18.75 30 248
Average= 4.69
(KJ/cycle)

Cycle 2 GMT 18/ 4/2025 0:50: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.28 45 14.86 362 242 0.24 / 6.33 2 3
2 3 1042.52 1 15.09 1631 25 0.27 / 6.35 2 3
3 3 1034.00 1 15.09 1619 24 0.29 / 6.38 2 2
4 8 1520.16 145 14.62 2116 4486 4.78 / 10.86 2 4
5 14 146.52 16 14.94 429 103 4.88 / 10.97 2 5
6 14 107.40 16 14.94 375 90 4.97 / 11.06 2 5
7 14 91.36 16 14.93 348 83 5.05 / 11.14 2 5
8 14 71.00 16 14.92 317 76 5.13 / 11.22 2 5
9 14 44.76 16 14.91 277 66 5.19 / 11.28 2 5
10 14 15.92 16 14.89 235 56 5.25 / 11.34 2 5
11 9 0.12 196 14.89 207 604 5.85 / 11.94 2 57
12 15 0.08 24 14.87 187 67 5.92 / 12.01 37 247
Average= 4.00
(KJ/cycle)

Cycle 1 GMT 17/ 4/2025 14:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.12 45 15.03 341 231 0.23 / 2.01 3 3
2 11 1006.08 2 15.07 1561 47 0.28 / 2.06 2 3
3 8 1006.04 145 14.84 1479 3183 3.46 / 5.24 2 5
4 14 50.84 16 14.94 300 72 3.53 / 5.31 2 5
5 14 33.40 16 14.94 275 66 3.60 / 5.38 2 5
6 9 0.04 202 14.91 218 657 4.25 / 6.03 2 55
7 15 -0.16 18 14.88 209 56 4.31 / 6.09 34 247
Average= 3.04
(KJ/cycle)

Cycle 0 GMT 17/ 4/2025 7:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 135.80 45 15.30 375 258 0.26 / 0.26 3 3
2 8 165.56 145 15.23 394 870 1.13 / 1.13 3 3
3 14 37.12 16 15.18 227 55 1.18 / 1.18 3 3
4 9 0.24 204 15.14 179 553 1.74 / 1.74 3 52
5 15 0.08 16 15.12 171 41 1.78 / 1.78 36 247
Average= 1.78
(KJ/cycle)